Sie sind auf Seite 1von 3

A.S.L.

PAULS COLLEGE OF ENGINEERING AND TECHNOLOGY,COIMBATORE109 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING LESSION PLAN Year &Semester:III&V Name of the Faculty:Mr.C.PITCHAI Designation:LECT URER Department: ELECTRICAL AND ELECTRONICS ENGINEERING BOOK&PAGE LECT TOPICS NO. USED UNIT NO UR FOR NO TEACHING 1 Introduction& Structure of electric power JERALDIN AHILA(1.1-1.3) system UNIT I JERALDIN 2&3 Sources of Electric Energy; Load POWER AHILA(1.4Characteristics GENERATION 1.05) JERALDIN 4 Economic Aspects; 5 6 7 8 1 2 UNIT II TRANSMISSION LINE PARAMETERS 3 4 5 6 7 8 9 1 2 Power Plants: Steam, Power Plants : Hydroelectric, Nuclear, Gas Wind and Solar
Parameters of resistance, inductance and capacitance calculations Single and three phase transmission lines, single and double circuits Solid, stranded and bundled conductors, symmetrical and unsymmetrical spacing Transposition of lines Concepts of GMR and GMD Skin and proximity effects, Interference with neighboring communication circuits Corona discharge characteristics, critical voltage and loss (Simple diagrams of typical towers and conductors for 400, 220 and 110 kV operations)
AHILA(1.261.28) JERALDIN AHILA(1.6 -1.10) JERALDIN AHILA(1.111.14) JERALDIN AHILA(1.141.20) JERALDIN AHILA(1.201.25) JERALDIN AHILA(3.1-3.5) JERALDIN AHILA(3.03.07) JERALDIN AHILA(3.083.10) JERALDIN AHILA(3.103.14) JERALDIN AHILA(3.153.20) JERALDIN AHILA(3.303.38) JERALDIN AHILA(3.503.59) JERALDIN AHILA(3.603.70) JERALDIN AHILA(3.1-3.5) JERALDIN AHILA(4.1-4.5) JERALDIN

Example Problems Solved Classification of lines: Short line, medium line and long line Equivalent circuits, attenuation

UNIT III ANALYSIS OF TRANSMISSION LINES

constant 3&4 5 6 7 8 9&10 11 12 1 2 Phase constant, surge impedance Transmission efficiency and voltage regulation Real and reactive power flow in lines Power-angle diagram; surge-impedance loading, load ability limits based on thermal loading, shunt and series compensation angle and voltage stability considerations Ferranti effect and corona loss Calculation of sag and tension
Classification of insulators for transmission and distribution purpose Voltage distribution in insulator string and grading Improvement of string efficiency Underground cables, constructional features of LT and HT cables Insulation resistance, capacitance, dielectric stress and grading Tan and power loss, Thermal characteristics

AHILA(4.64.10) JERALDIN AHILA(4.114.20) JERALDIN AHILA(4.214.28) JERALDIN AHILA(4.294.41) JERALDIN AHILA(4.504.60) JERALDIN AHILA(5.15.10) JERALDIN AHILA4.744.79) JERALDIN AHILA(5.14-5.21) JERALDIN AHILA(6.1.-6.9) JERALDIN AHILA(7.1-7.5) JERALDIN AHILA(7.1-7.5) JERALDIN AHILA(7.67.10) JERALDIN AHILA(8.18.8.7) JERALDIN AHILA(8.88.20) JERALDIN AHILA JERALDIN AHILA(11.111.4) JERALDIN AHILA(11.0511.11&11.5411.60 ) JERALDIN AHILA(11.1511.28) JERALDIN AHILA(2.212.22) JERALDIN AHILA(2.222.27) JERALDIN AHILA JERALDIN AHILA(2.12.17)

UNIT IV INSULATO R AND CABLES

3 4 5&6 7 1

Radial and ring-main distributors AC distribution: AC distributor with concentrated load Three-phase, four-wire distribution system; DC distribution; sub-mains; stepped and tapered mains FACTS TCSC, SVC STATCOM, UPFC Introduction HVDC
Merits & Demerits of HVDC, EHV AC transmission

UNIT V DISTRIBUT ION SYSTEM &FACTS TECHNOLO GY

2&3 4 5 6&7 8 9&10

Staff Incharge

HOD

Principal

Das könnte Ihnen auch gefallen