RT880/TMS875TeleCylinderWearedeeplyconcernedwithrepetitivefailureofP3573TeleCylinder.
FailureModes (a)InternalLeakageCreep
(b)VisibleLeakagethroughRodseal
(c)Scoringofpistonrod
Summary
TotalFailureInstances9(excludingthecaseofweldarchinginJSPL)
NoofFailureInstancesofInternalLeakage/Creep4
NoofFailureInstancesofVisibleLeakagethroughRodSeal5
AffectedcustomersJSPL,ESSARProjectsandNCL
CylinderSerialNoSeriesK5,K7,K8andJZ
4Cylindersoutof9havebeenreturnedtoWIPRO,BLR
FailedCylindersdispatchedfromsiteon18Jun12
Outofthe4returnedcylinders,twoarefromJSPLandtwofromESSARProjects
Outofthe4returnedcylinders,twoarerelatedtocreepandanothertwoarerelatedtoVisibleLeakage
TILisyettoreceiveanyofficialfailureinvestigationreport
TILhassofarfitted75TeleCylinders
FailureRate12%
WeunderstandthatwefL5L00233WIPROhasimplementedsealingconceptofGROVE
Themachineswithmodifiedcylindersareyettoworksignificanthourstotakeadecision
Thecompletelistofcylindersfittedsofarwrtmachineserialnoshasbeenprovidedinthenextpage.Few
cylinderserialnosaremissing.
Theissueneedstobetakenupseriously
Page1of4
DateofReview11Sep2012
MachineModel
TMS875
SerialNo
38502
38503
38504
38507
38506
38505
38508
38509
406767
406959
406984
406985
407085
407263
407283
407305
407304
407264
407231
407233
407142
407086
CustomerName
CHANDI CRANES
SerialNo
K9L00391,KXL00373,
SHRADHA ENGINEERING
KYL00259,KZL00058
CHAUDHARY CRANES
L1L00229,L1L00119,
LARSEN& TOUBRO
L4L00082,L4L00210,
APOLLO ENTERPRISES
L3L00530,L3L00657,
LARSEN& TOUBRO
L5L00233,L4L00066,
APOLLO ENTERPRISES
L5L00449,L7L00162,
K2L00003,K3L00218, K3L00332
ESSAR PROJECTS
K3L00365,K5L00361, K5L00360
SEW INFRASTRUCTURE
K2L00008,K2L00079, K5L00355
JSPL
JZL00466,JZL00365, JZL00383
NORTHERN COALFIELDS
MAHANADI COALFIELDS
MAHANADI COALFIELDS
MAHANADI COALFIELDS
BSC C&C'JV'
JSPL
L1L00183,L1L00075, KZL00336
RT880
407087
JSPL
RT880
407088
JSPL
RT880
407141
NORTHERN COALFIELDS
K7L00237,7L00247,K7L00241
K7L00259,K8L00006
8L00074,K8L00077,K8L00048
TMS875
TMS875
TMS875
TMS875
TMS875
TMS875
TMS875
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
RT880
L2L00245,L2L00073,
J5L00897,J5L01001, J5L01100
L3L00363,L3L00444, L3L00445
L3L00052,L3L00074, L3L00095
L1L00571,L2L00473,
L1L00561,L2L00002, L2L00005
L1L00376,L1L00419, L1L00148
KZL00155,ZL00130,KZL00103
KYL00077,KYL00003,
K7L00100,6L00307,K7L00133
Page2of4
DateofReview11Sep2012
2.
RT760(P8131/P9610)TeleCylinder
FailureModes(a)InternalLeakageCreep
Summary
3.
4.
5.
6.
7.
TotalFailureInstances3
AffectedcustomerUltratechCement
CylinderSerialNoSeriesJYandK3
OnecylinderhasbeenreturnedtoWIPRO,BLR
Thefailureinvestigationreportisnotconclusive
TILisyettoreceiveanyfeedbackonfutureCAPA
ExpediteAnalysisoffailedmaterialSometimesitistakingtoolongtimeeg825Telea/cArihantCargo
FailureModeCreepSealKitreplacedFailedmaterialreceivedatWIPROon29Feb12.Nofeedbackon
RCA.
TIL has approved improved version of design of following cylinders. No feedback on physical
implementation.
TypeofCylinder
MachineModel
WIPROP/NO
Lift
RT880
P9812
Lift
RT740B
P5226
O/RJack
RT880
P3545
O/RJack
RT760
P3698
O/RJack
RT740B
P3439
O/RRam
RT740B
P3124
O/RRam
RT760
P3347
O/RRam
RT880
P3357
O/RRam
TMS750B
P3423
Feedbackisrequiredonimplementationplanofwiperguardaswell.
TILhasnofeedbackonphysicalimplementationofUltrasonicCleaningBathinMHLineofHindupurPlant.It
wasscheduledtobeimplementedinJuly2012.
TILhasnofeedbackonphysicalimplementationofAssemblyFixturesinMHLineofHindupurPlant.Itwas
scheduledtobeimplementedinJuly2012.
Page3of4
DateofReview11Sep2012
8.
HYSTERLiftCylinder
FailureModes (a)PistonRodScoring
(b)OilSeepagethroughHECORing
Summary
NoFieldIssueatthemomentoncylinderswithmodifieddesign
MachineNo25withmodifieddesignhasclockedmorethan3200hrswithoutanyissueonpistonrod
CylinderswithimprovedsurfacefinishatHECORingseatinghavebeenfittedwefApril2012despatch.
Needstobemonitoredfurtherforeffectivenessoftheactions.
WIPROneedstosupportTILforpendingissuesrelatedtoLiftCylinderCampaignChange.
Page4of4
DateofReview11Sep2012