CONTENTS
Section I DESCRIPTION
CONTENTS
TITLE
1 2 2.1 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.2.7 2.2.8
PAGE
GENERAL DESCRIPTION 1-1 SYSTEM CONFIGURATION AND CHARACTERISTICS 2-1 System Configuration 2-1 Performance Characteristics 2-15 General System 2-15 LAN Interface (10/100 Base-T(X)) 2-17 LAN Interface (GbE) 2-19 Service Channel (SC) 2-20 LCT (PNMT) Interface 2-20 PNMS Interface 2-20 ODU (Outdoor Unit) and System performance 2-22 IDU (Indoor Unit) and System performance 2-26
2.3 Interconnection between ODU and IDU 2-30 2.4 2.4.1 2.4.2 2.5 2.6 Hybrid Combiner/Divider 2-31 10 dB Coupler 2-32 OMT (Ortho-Mode Transducer) 2-33 RF Channel Plan 2-34 Power Supply 2-35
CL-1
CONTENTS
ROI-S05748
CL-2 2 pages
ROI-S05748
GENERAL DESCRIPTION
1. GENERAL DESCRIPTION
This section provides descriptive information on the PASOLINK NEO radios which are used for the wide/narrow band point-to-point digital microwave radio links. The Indoor Unit (IDU) provides digital PDH (5-48 E1, 1/2 E3), SDH (1/2 STM-1) and LAN (2 10/100Base-TX) signal transmission by the change of the data signal interface card. It can select the modulation method QPSK/16QAM/32QAM/128QAM, by software selection depending on the transmission capacity that is configured in the modulator/demodulator unit. The Outdoor Unit (ODU) can be applied for a wide range of RF frequency bands from 6/7/8/10/11/13/15/18/23/26/32/38/52 GHz. Applications using the following redundancy configurations, Unprotected (1+0), 2 (1+0)* and Protected (1+1), 2 (1+1)* are available for PASOLINK NEO radio systems. Note: * XPIC Cross Polarization Interference Canceller (XPIC) system is applied for dual polarized systems using the same frequency in 2 (1+0) and 2 (1+1) configurations.
1-1
GENERAL DESCRIPTION
ROI-S05748
PASOLINK NEO
0678
IDU Package Label
PASOLINK NEO MDP-150MB-1AA INDOOR UNIT
1+0 1+1 XPIC ETSI (RACK) LABEL( EN FR ES DE IT) INTFC(1) STM1-E STM1-0 LAN/WS GbE 16E1( ) 48E1 OTHER( ) INTFC(2) STM1-0 LAN/WS OTHER( )
NWM-001846-001
0678
PASOLINK NEO MDP-150MB-1AA INDOOR UNIT
1+0 1+1 XPIC ETSI (RACK) LABEL( EN FR ES DE IT) INTFC(1) STM1-E STM1-0 LAN/WS GbE 16E1( ) 48E1 OTHER( ) INTFC(2) STM1-0 LAN/WS OTHER( )
NWM-001846-001
MADE IN JAPAN
MADE IN JAPAN
MODEM(1)
INTFC (1)
INTFC (2)
0678
(H2930)
MADE IN JAPAN
XPIC CTRL
TX RX XPIC RESET
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
EOW
CALL
IDU 1+0
! IF IN/OUT
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
G PULL ALM PWR G PULL PWR LCT NMS NE AUX/ALM 2M IN/OUT-A 2M IN/OUT-B 100M PORT 1 PORT 2 100M
G
XPIC CTRL
TX RX XPIC RESET
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
SC IN/OUT
EOW
CALL
IDU 1+1
PASOLINK NEO
TRP-( )G-1B OUTDOOR UNIT (NHG) SHIFT FREQUENCY
0678
(NWA-009034)
PASOLINK NEO
TX HIGH/LOW
0678
(NWA-009034)
SERIAL No.
DATE
MADE IN JAPAN
TX HIGH/LOW
SERIAL No.
DATE
MADE IN JAPAN
CAUTION
Non-ionizing radiation
-48V INPUT
Power down IDU before disconnection or connection of cable.
CAUTION
Non-ionizing radiation
-48V INPUT
Power down IDU before disconnection or connection of cable.
RX LEV MON
IFL
FG
ODU
1-2 2 pages
ROI-S05748
Table 2-1 System General Performance (1/2) Table 2-12 System Performance for IDU Table 2-13 Alarm & House Keeping Output Items Table 2-14 House keeping input Items Table 2-16 Characteristics Table 2-17 Characteristics Table 2-18 Characteristics Table 2-19 RF Frequencies
2-1
ROI-S05748
RF Cable ODU
f1 f1
f1 f1
2-2
ROI-S05748
1+0 IDU DATA1 IN/OUT IDU XPIC CTRL Cable DATA2 IN/OUT IDU IDU X IF Cable IDU 1+0 IDU IF Cable ODU (Working) OMT IF Cable ODU (Working) H (V) V (H) f1 f1 f1 f1 V (H) ODU (Working) OMT H (V) ODU (Working) IF Cable IF Cable
IDU XPIC IDU X IF Cable CTRL Cable IDU 1+0 IDU DATA2 IN/OUT
IDU XPIC IDU CTRL X IF Cable Cable DATA2 IN/OUT IDU 1+0 IDU
IDU IDU XPIC X IF Cable CTRL Cable IDU 1+0 IDU DATA2 IN/OUT
1+0 IDU DATA1 IN/OUT IDU IF Cable ODU (Working) V (H) OMT IF Cable DATA2 IN/OUT IDU 1+0 IDU ODU (Working) H (V) f1 f1 f1 f1 V (H) ODU (Working) OMT H (V) ODU (Working) IF Cable IF Cable
IDU IDU XPIC X IF Cable CTRL Cable DATA2 IDU IN/OUT 1+0 IDU
2-3
ROI-S05748
MAIN DATA INTFC (Selectable) 16E1 (5/10/16 2 MB) G.703 16E1 (0 to 16 2 MB G.703 + 40 to 8 MB 10/100base T(x) IEEE 802.3) E3 (1/2 34 MB + 4/8 2 MB) G.703 48E1 (5/10/20/40/48 2 MB) G.703 STM-1 (155 MB ELE) G.703 STM-1 (155 MB OPT) G.957, S-1.1/L-1.1 10/100 Base T(X) 2-Port LAN IEEE802.3 1000 Base T/SX IEEE 802.3z MAIN DATA INTFC (for APS) STM-1 (155 MB OPT) ITU-T G.957, S-1.1/L-1.1 WS/LAN INTFC (Additional) WS (1 2 MB) + 64/128/192/256 KB SC- LAN ALM/HK/SC (AUX) INTFC SC (2 64 KB V.11 + 2 9.6 KB RS-232C) + EOW (1 ) 6 ALM OUT (4 HK OUT/4 Cluster OUT) 6 HK IN/4 Cluster IN 128QAM
IDU
QPSK/16QAM
QPSK/16QAM/32QAM
128QAM 6 to 52 GHz
ODU
128QAM
1+0/1+1 Configuration
Fig. 2-2 Signal Interface/Capacity (1/2)
2-4
ROI-S05748
MAIN DATA INTFC (Selectable) STM-1 (155 MB ELE) G.703 STM-1 (155 MB OPT) G.957, S-1.1/L-1.1 10/100 Base T(X) 2-Port LAN IEEE 802.3 1000 Base T/SX IEEE 802.3z MAIN DATA INTFC (for APS) STM-1 (155 MB OPT) G.957, S-1.1/L-1.1 WS/SC-LAN INTFC (Additional) WS (1 2 MB) + 64/128/192/256 KB SC- LAN ALM/HK/SC(AUX) SC (2 64 KB V.11 + 2 9.6 KB RS-232C) + EOW (1 )
IDU
No.1 128QAM
6 ALM OUT (4 HK OUT/4 Cluster OUT) 6 HK IN/4 Cluster IN MAIN DATA INTFC (Selectable) STM-1 (155 MB ELE) G.703 STM-1 (155 MB OPT) G.957, S-1.1/L-1.1 10/100 Base T(X) 2-Port LAN 1000 Base T/SX IEEE 802.3z MAIN DATA INTFC (for APS) STM-1 (155 MB OPT) G.957, S-1.1/L-1.1 WS/SC-LAN INTFC (Additional) WS (1 2 MB) + 64/128/192/256 KB SC- LAN ALM/HK/SC(AUX) SC (2 64 KB V.11 + 2 64 KB RS-232C) + EOW (1 ) 6 ALM OUT (4 HK OUT/4 Cluster OUT) 6 HK IN/4 Cluster IN No.2 128QAM
XPIC Configuration
Fig. 2-2 Signal Interface/Capacity (2/2)
2-5
ROI-S05748
! IF IN/OUT
XPIC CTRL
TX RX XPIC RESET
(Blank)
G
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
(Blank)
LCT
NMS
NE
AUX/ALM
SC IN/OUT
EOW
CALL
XPIC CTRL
TX RX XPIC RESET
PULL ALM PWR STM-1 OUT STM-1 IN ONLINE STM-1 OUT STM-1 IN ONLINE ALM
G
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL
XPIC CTRL
TX RX XPIC RESET
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
EOW
CALL
XPIC CTRL
TX RX XPIC RESET
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL
XPIC CTRL
TX RX XPIC RESET
PULL PWR
E3 CH1
IN
OUT
IN
OUT
100M
PORT 1
PORT 2
100M
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL
XPIC CTRL
TX RX XPIC RESET
(Blank)
G
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL
! IF IN/OUT
XPIC CTRL
TX RX XPIC RESET
(Blank)
G
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
(Blank)
LCT NMS NE AUX/ALM SC IN/OUT EOW CALL
XPIC CTRL
TX RX XPIC RESET
(Blank)
G
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
STD
FUSE (250V/8AH)
SELV
SC IN/OUT
EOW
CALL
2-6
ROI-S05748
! IF IN/OUT
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
(Blank)
PROTECT
XPIC CTRL
TX RX XPIC RESET
PASOLINK NEO
MAINT MEMORY IDU MMC
SC IN/OUT
EOW
CALL
XPIC CTRL
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
PULL ALM PWR STM-1 OUT STM-1 IN ONLINE STM-1 OUT STM-1 IN ONLINE ALM
G
PULL PWR
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
XPIC CTRL
LCT
NMS
NE
AUX/ALM
SC IN/OUT
EOW
CALL
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
G PULL ALM PWR G PULL PWR LCT NMS NE AUX/ALM 2M IN/OUT-A 2M IN/OUT-B 100M PORT 1 PORT 2 100M
G
XPIC CTRL
TX RX XPIC RESET
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
SC IN/OUT
EOW
CALL
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
XPIC CTRL
TX RX XPIC RESET
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
SC IN/OUT
EOW
CALL
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
PULL PWR
E3 CH1
IN
OUT
IN
OUT
100M
PORT 1
PORT 2
100M
XPIC CTRL
TX RX XPIC RESET
PULL PWR
PROTECT
PASOLINK NEO
MAINT MEMORY IDU MMC
LCT
NMS
NE
AUX/ALM
SC IN/OUT
EOW
CALL
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
(Blank)
PROTECT
XPIC CTRL
TX RX XPIC RESET
PASOLINK NEO
MAINT MEMORY IDU MMC
SC IN/OUT
EOW
CALL
! IF IN/OUT
XPIC CTRL
TX RX XPIC RESET
PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV
(Blank)
PROTECT
XPIC CTRL
TX RX XPIC RESET
PASOLINK NEO
MAINT MEMORY IDU MMC
SC IN/OUT
EOW
CALL
2-7
ROI-S05748
ODU
ODU
OMT
ODU
ODU
2-8
ROI-S05748
HYB
ODU
ODU ODU
ODU
2-9
ROI-S05748
ODU
ODU
ODU
ODU
2-10
ROI-S05748
6 to 52 GHz
IDU 16E1+2PORT LAN/ 48E1/ 1/2E3 IN/OUT MODEM ( )INTFC *
DPU/ FEC
ODU
fL(H) fH(L)
ODU INTFC
ALM IN/OUT SC IN/OUT NMS LCT NE EOW EOW (JACK) PS IN CTRL DC-DC CONV PS SYNTH (LO) CTRL
ODU
fL(H) fH(L)
ODU INTFC
STM-1 (OPT)
( )INTFC *2
WS/SC-LAN
2-11
ROI-S05748
ODU
HYB
ODU INTFC
ALM IN/OUT SC IN/OUT NMS LCT NE EOW EOW (JACK) PS IN ODU fH(L) MODEM
DPU/ FEC
CTRL
6 to 52 GHz
fL(H)
ODU INTFC
PS PS IN CTRL
SYNTH (LO)
Note:
* :Optional
2-12
ROI-S05748
IDU STM-1 (ELE)/ STM-1 (OPT)/ 2-PORT LAN/WS GbE IN/OUT MODEM ( )INTFC *1
DPU/ FEC
ODU
HYB
ODU INTFC
STM-1 (OPT)
WS/SC-LAN
LAN/WS INTFC *3
6 to 52 GHz
fL(H)
fH(L) CTRL
ODU
128QAM/ MODEM
ODU INTFC
2-13
ROI-S05748
IDU STM-1 (ELE)/ STM-1 (OPT)/ 2-PORT LAN/WS GbE IN/OUT MODEM ( )INTFC *1
DPU/ FEC
ODU
OMT
ODU INTFC
STM-1 (OPT)
WS/SC-LAN
LAN/WS INTFC *3
6 to 52 GHz
fL(H)
V(H) H(V) H(V) V(H)
ALM IN/OUT SC IN/OUT NMS LCT NE EOW EOW (JACK) PS IN fH(L) CTRL
ODU
ODU INTFC
( )INTFC *1
STM-1 (OPT)
( )INTFC *2
PS
WS/SC-LAN
LAN/WS INTFC *3
2-14
ROI-S05748
Capacity Interface Interconnecting Connector, Cable impedance and Cable length (IDU-ODU) Channel Spacing *1 QPSK 16 QAM 32 QAM 128 QAM Environmental Requirement Guaranteed Operation Workable Operation Transportation/ Storage Relative humidity EMC Safety Power Requirement Power Consumption (Typical) ODU/Unit IDU Card/Unit MODEM 48E1 INTFC (for 48 E1) 16E1 INTFC (for 16 E1) E3 INTFC CTRL
Weight/Card
Up to 100 Mbps D-sub 37: 16 E1/MDR68: 48E1/ IEC 169-29(1.0/2.3): 1/2E3 RJ-45 10/100 Base-T(X)
ODU side: N type female, 50 ohms (Coaxial) IDU side: TNC type female, 50 ohms (Coaxial) 300m (in case 8D-FB cable or equivalent cable) 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz 3.5 MHz, 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz 28 (27.5) MHz Not Applicable ODU: 33 to +50C IDU: 5 to +50C ODU: 40 to +55C IDU: 10 to +55C ODU, IDU: 40 to +70C ODU: 100% applicable IDU: Less than 90% at +50C (Non-codensing) Conforms to EN301 489-4 Conforms to EN60950 48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2 30 W (6 to 11 GHz), 23 W (13 to 52 GHz) 10 W 8W 8W 8W 7W MODEM: 0.5 kg, 48E1 INTFC (for 48 E1): 0.4 kg, 16E1 INTFC (for 16 E1): 0.4 kg, E3 INTFC (for E3): 0.4 kg, CTRL: 0.4 kg
Mechanical Dimension
ODU IDU
237(W) 237(H) 101(D): Approx. 3.5 kg/Unit 482(W) 44(H) 240(D): Approx.4 kg
Notes *1: 13.75 or 27.5 MHz is applied for 18 GHz. *2: For 48E1 INTFC, the LAN is not applicable.
2-15
ROI-S05748
Capacity Interface
Interconnecting Connector, Cable impedance and Cable length (IDU-ODU) Channel Spacing *1 QPSK (PDH) 16QAM (PDH) 32QAM (PDH) 128QAM Environmental Requirement Guaranteed Operation Workable Operation Transportation/ Storage Relative humidity EMC Safety Power Requirement Power Consumption (Typical) ODU/Unit IDU Card/Unit MODEM STM-1O INTFC STM-1E INTFC LAN/WS INTFC CTRL
Weight/Card
ODU side: N type female, 50 ohms (Coaxial) IDU side: TNC type female, 50 ohms (Coaxial) 300m (in case 8D-FB cable or equivalent cable)
Not Applicable 28 (27.5) MHz 28 (27.5) MHz ODU: 33 to +50C IDU: 5 to +50C ODU: 40 to +55C IDU: 10 to +55C ODU, IDU: 40 to +70C ODU: 100% applicable IDU: Less than 90% at +50C (Non-codensing) Conforms to EN301 489-4 Conforms to EN60950 48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2 30 W (6 to 11GHz), 23 W (13 to 52 GHz) 10 W 5W 5W 7W MODEM: 0.5 kg, STM-1O INTFC: 0.3 kg, STM-1E INTFC: 0.3 kg, LAN/WS INTFC: 0.3 kg, CTRL: 0.4 kg 5W
Mechanical Dimension
ODU IDU
237(W) 237(H) 101(D): Approx. 3.5 kg/Unit 482(W) 44(H) 240(D): Approx.4 kg
Notes *1: 27.5 MHz is applied for 18 GHz. *2: 2 155Mbps using 2 sets for XPIC *3: 2 for APS configuration
2-16
ROI-S05748
LAN Setting LAN capacity [Mbps] Port 1 Port 2 150 150 150 100 P1 & P2 = 150 M Best effort (separated) P1 = 75 M separated P1 = 100 M separated P1 = 100 M separated P2 = 75 M separated P2 = 50 M separated Disabled
2-17
ROI-S05748
P1 & P2 = 80 M shared *1 P1 & P2=shared from 80M to 48M P1 & P2 = 48M shared P1 = 40M separated P1 = 30M separated P1 = 24M separated Disabled P2 = 40M separated P2 = 30M separated P2 = 24M separated Disabled
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode) (2) 2 Port LAN with PDH INTFC
Table 2-4 2 Port LAN 40 Mbps (16QAM/QPSK)
P1 & P2 = 40 M shared *1 P1 & P2=shared from 40M to 8M P1 & P2 = 8M shared P1 = 20M separated P1 = 10M separated P1 = 4M separated Disabled P2 = 20M separated P2 = 10M separated P2 = 4M separated Disabled
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
2-18
ROI-S05748
P1 & P2 = 20M shared P1 & P2= shared from 20M to 4M P1 & P2 = 2M shared P1 = 10M separated Disabled P2 = 10M separated Disabled
P1 & P2 = 10M shared P1 & P2 = shared from 10M to 2M P1 & P2 = 2M shared Disabled Disabled
2-19
ROI-S05748
2-20
ROI-S05748
Connector
2.2.6.3 Wayside
In case of 155 Mbps capacity, one (1) wayside channel can be used as E1 using optional LAN/WS interface card. In case of 2E3 INTFC, eight (8) wayside channels can be used as E1 or LAN INTFC In case of 1E3 INTFC, four (4) wayside channels can be used as E1 or LAN INTFC
2-21
ROI-S05748
Interface type
NEC Original
*2
PDR 100
PBR 120
PBR 140
PBR 220
PBR 220
PBR 260
PBR 320
PBR 320
PBR 320
N/A
Output Power, nominal (dBm) (Measured at ODU output port) Power Control (1 dB step, variable) ATPC (1 dB step) Frequency Stability Threshold Level Channel Separation (CS)= 28 (27.5)
+25
+25
+23
+24
+24
+22
+22
+22
+18
+3
0 to 30 dB
*3 *3
6 ppm
0 to 25 dB
*4 *4
0 to 10 dB
0 to 30 dB
0 to 25 dB
0 to 10 dB
*1 MHz *1
MHz 87 90 86 89 86 89 86.5 89.5 86.5 89.5 86.5 89.5 86 89 86 89 84.5 87.5 84.5 87.5 81 84
14 (13.75) 7 MHz
BER = 10-3 System Gain Channel Separation (CS)= 28 (27.5) 113 108
Above value 1.5 dB (dB), (Measured at ODU input port) at BER = 10 108 106.5 107.5 107.5 105
-6
103.5 99.5 81 6-26G:3.0 dB 28-52G:4.0 dB
105
*1 *1
MHz MHz 116 119 111 114 111 114 109.5 112.5 110.5 113.5 110.5 113.5 108 111 108 111 106.5 109.5 102.5 105.5 84 87
14 (13.75) 7 MHz
*1 *2
13.75 MHz and 27.5 MHz are applied for 18 GHz. For the ODU of waveguide connection type, flange adapter is attached to the RF IN/OUT port of remote mount ODU in standard. When additional 5 dB (maximum) attenuation is added. Additional attenuation is unavailable.
*3 *4
2-22
ROI-S05748
Interface type
NEC Original
*2
PDR 100
PBR 120
PBR 140
PBR 220
PBR 220
PBR 260
PBR 320
PBR 320
PBR 320
Output Power, nominal (dBm) (Measured at ODU output port) Power Control (1 dB step, variable) ATPC range Frequency Stability Threshold Level Channel Separation (CS) = 28 (27.5)
+21.5
+22.5
+22.5
+22
+22
+20
+18
+17
0 to 24 dB
*3 *3
0 to 24 dB
6 ppm (dBm), (Measured at ODU input port) at BER = 10 77 76 76 76.5 76.5 76.5 76
-6
76 74.5 74.5
*1 *1
MHz MHz 80 83 86 79 82 85 79 82 85 79.5 82.5 85.5 79.5 82.5 85.5 79.5 82.5 85.5 79 82 85 79 82 85 77.5 80.5 83.5 77.5 80.5 83.5 +3.0 dB
-3
Above value 1.5 dB (dB) , (Measured at ODU input port) at BER = 10 103 97.5 98.5 99 98.5 98.5 96
-6
94 91.5 89 3.0 dB
*1
MHz 106 109 112 100.5 103.5 106.5 101.5 104.5 107.5 102 105 108 101.5 104.5 107.5 101.5 104.5 107.5 99 102 105 97 100 103 94.5 97.5 10.5 92 95 98
*1 MHz 14 (13.75)
7 MHz 3.5 MHz BER = 10-3 Maximum Input Level Residual BER
Less than 10
*1 *2
13.75 MHz and 27.5 MHz are applied for 18 GHz. For the ODU of waveguide connection type, flange adapter is attached to the RF IN/OUT port of remote mount ODU in standard. Additional attenuation is unavailable.
*3
2-23
ROI-S05748
Interface type
NEC Original
*2
PDR 100
PBR 120
PBR 140
PBR 220
PBR 220
PBR 260
PBR 320
PBR 320
PBR 320
N/A
Output Power, nominal (dBm) (Measured at ODU output port) Power Control (1 dB step, variable) ATPC (1 dB step) Frequency Stability Threshold Level Channel Separation (CS)= 28 (27.5)
+21
+21
+21
+19
+19
+18
+18
+17
+14.5
0 to 28 dB
*3 *3
0 to 6 dB
0 to 28 dB
0 to 6 dB
6 ppm
*1 MHz
Above value 1.5 dB (dB), (Measured at ODU input port) at BER = 10 100.5 95.5 95.5 96 94 94 92.5 92.5
-6
90 87.5 66.5
3.0 dB
92.5
*1
*1 *2
27.5 MHz is applied for 18 GHz. For the ODU of waveguide connection type, flange adapter is attached to the RF IN/OUT port of remote mount ODU in standard. When additional 5 dB (maximum) attenuation is added.
*3
2-24
ROI-S05748
Interface type
NEC Original
*2
PDR 100
PBR 120
PBR 140
PBR 220
PBR 220
PBR 260
PBR 320
PBR 320
PBR 320
Output Power, nominal (dBm) (Measured at ODU output port) Power Control (1 dB step, variable) ATPC range) Frequency Stability Threshold Level Channel Separation (CS)= 28 (27.5)
+21
+21
+21
+19
+19
+18
+18
+17
0 to 25 dB
*3 *3
6 ppm
0 to 20 dB
*4 *4
0 to 25 dB
0 to 20 dB
*1
MHz Above value 1.5 dB (dB), (Measured at ODU input port) at BER = 10 94.5 89.5 89.5 90 88 88 86.5
-6
86.5 84 81.5
3.0 dB
*1 MHz
Above value +1.5 dB 20
Less than 10
*1 *2 *3 *4
27.5 MHz is applied for 18 GHz. For the ODU of waveguide connection type, flange adapter is attached to the RF IN/OUT port in standard. When additional 5 dB (maximum) attenuation is added. Additional attenuation is unavailable.
2-25
ROI-S05748
PDH
SDH
LAN
1 2 3
Service Channels EOW External alarm & House keeping 7 Security level by LCT 2 levels 8 Control &Setting by Serial Interface (USB connector) LCT/PNMT Loop Back a) Far End Baseband Loop Back b) Near End Baseband Loop Back c) IF Loop back BER Alarm Adjustable 10-3/ 10-4/ 10-5 (High BER) 10-6/ 10-7/ 10-8/ 10-9 (Low BER) Frequency setting Direct entry or Table Download entry: Available when using PNMx (optional) TX output Control Manual control, Automatic control, Mute control 9 Performance PMON Items; monitoring (PMON) a) OFS, b) BBE, c) ES, d) SES, e) SEP, f) UAS /Metering Metering Items a) Output power level (TX PWR), b) Received signal level (AGC V) c) Bit error rate (BER MON) LAN monitoring Items; a) RX Unicast, b) RX Broadcast, c) RX Multicast, d) RX Pause, e) RX CRC error 10 LED Display CTRL IDU Alarm (Red) Maintenance (Amber) Memory Access (Amber) MODEM Operating PWR (Green) ODU Alarm (Red) MD/CBL Alarm (Red) TX status (Green) RX status (Green) XPIC Reset (Amber)* PDH INTFC Module alarm (Red) SDH INTFC Module alarm (Red) Online (Green)** LAN/WS INTFC Module alarm (Red)
1+0 Expandable/1+1 QPSK/16/32QAM 128QAM QPSK/16/32/128QAM E3: 155.52 Mbps 20 ppm 10/100 Base-T(X) E1: 1000 Base-SX 2.048 Mbps 50 ppm 34.368 Mbps 20 ppm 1000 Base-T 75 ohm/120 ohm 75 ohm 75 ohm/S-1.1/L-1.1 D-sub37/MDR68 IEC 169-29 (1.0/2.3) IEC 169-29 (1.0/2.3) RJ-45 (10/100/1000 Base-T(X)) LC (1000 Base-SX) 5/10/16/20/40/48 1/2 1/2* 1/2 10/20/32/40/80/96 34/68 Mbps 155 Mbps 10/20/40/80/100/100+50, Mbps 75+75 Mbps V.11 (Contra/Co-directional) 2 channels, RS-232C 2 channels IDU-IDU See table below
* This value is available with 2 IDUs per 1 RF CH with XPIC system. ** This indicates the online status which is selected from Working/Standby in APS system or Warking in w/o APS system.
2-26
ROI-S05748
ODU2 total alarm ODU ODU1 CPU failure or IF cable is Blinking open 8 ODU CPU/CBL ODU2 CPU failure or IF cable is OPN ALM2 open 9 TX PWR ALM1 ODU1 output power decrease ODU 10 TX PWR ALM2 ODU2 output power decrease 11 TX INPUT ALM1 ODU1 TX IF input level decrease ODU 12 TX INPUT ALM2 ODU2 TX IF input level decrease 13 APC ALM1 ODU1 LO OSC APC loop out of ODU lock 14 APC ALM2 ODU2 LO OSC APC loop out of lock 15 RX LEV ALM1 ODU1 Receiving level decrease ODU 16 RX LEV ALM2 ODU2 Receiving level decrease 17 IF CABLE SHORT IF Cable connected to ODU1 short IDU ALM1 MD/CBL Blinking 18 IF CABLE SHORT IF Cable connected to ODU2 short ALM2 19 IDU ALM IDU total alarm IDU 20 MOD ALM1 MOD PLL APC loop out of lock, IDU MOD output level down or TX MD/CBL DPU CLK loss in MODEM1 21 MOD ALM2 MOD PLL APC loop out of lock, MOD output level down or TX DPU CLK loss in MODEM2 22 DEM ALM1 Carrier Asynchronous, IDU Frame Asynchronous at DPU in MD/CBL MODEM1 23 DEM ALM2 Carrier Asynchronous, Frame Asynchronous at DPU in MODEM2 24 HIGH BER ALM1 BER > 10E-3 to -5 (selectable) in IDU MODEM1 MD/CBL 25 HIGH BER ALM2 BER > 10E-3 to -5 (selectable) in MODEM2 26 LOW BER ALM1 BER > 10E-6 to -9 (selectable) in IDU MODEM1 MD/CBL 27 LOW BER ALM2 BER > 10E-6 to -9 (selectable) in MODEM2 28 LOF1 Loss of Radio frame IDU synchronization in MODEM1 MD/CBL 29 LOF2 Loss of Radio frame synchronization in MODEM2 30 INPUT LOSS Loss of input data stream IDU INTFC CH 1-48 from DTE <Note 1> <Note7> AIS (all 1) is received IDU INTFC 31 AIS RCVD CH 1-48 from DTE <Note 1> <Note7> 32 AIS GENERATED AIS (all 1) is sent to IDU INTFC CH 1-48 DTE <Note 1> <Note7>
MAINT IDU CPU ALM PS ALM1 PS ALM2 ODU ALM1 ODU ALM2 ODU CPU/CBL OPN ALM1
System under maintenance IDU CPU failure PS1 failure (only1+1) PS2 failure (only1+1) ODU1 total alarm
2-27
ROI-S05748
Condition
Summarized Alarm Output (Form-C) <Note 3,4,5,10> RL1 RL2 RL3 RL4 RL5 RL6
33 CH USAGE ERROR 34 LAN LINK PORT 1-4 35 STM-1(1/2) LOS (MUX) 36 STM-1(1/2) LOS (DMR) 37 STM-1(1/2) TF ALM 38 WS INPUT LOSS 39 INTFC (2) LAN LINK PORT 40 XCTRL ALM1 41 XCTRL ALM2 42 XREF ALM1 43 XREF ALM2 44 HK-OUT1 45 HK-OUT2 46 HK-OUT3 47 HK-OUT4 48 Cluster ALM out1 49 Cluster ALM out2 50 Cluster ALM out3 51 Cluster ALM out4
Use of a channel set as not used (E1 channel) <Note 2> Loss of Main LAN Link <Note 3> Loss of input data stream from MUX <Note 3> Loss of input data stream from DMR <Note 3> Loss of STM-1 signal output to MUX <Note 3> Loss of Wayside signal input Loss of SC LAN Link Control failure or REF Signal failure Control failure or REF Signal failure Control failure or REF Signal failure Control failure or REF Signal failure House keeping Control out1 House keeping Control out2 House keeping Control out3 House keeping Control out4 This item received from opposite site. Item 1 This item received from opposite site. Item 2 This item received from opposite site. Item 3 This item received from opposite site. Item 4
IDU INTFC <Note7> IDU INTFC IDU INTFC <Note8> IDU INTFC <Note8> IDU INTFC <Note8> IDU INTFC <Note8> IDU INTFC <Note8> IDU INTFC <Note9> IDU INTFC <Note9> IDU INTFC <Note9> IDU INTFC <Note9> Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT
Note 1: Apply to each channel of E1/E3. Note 2: Unused channel/interface is masked according to the bit rate. Note 3: It is possible to change capacity between E1 and Ethernet under working condition. Note 4: In MAINT status, excepting HK-OUT and Cluster ALM, alarm outputs are masked to normal condition. Note 5: The summarization of alarm outputs is fully user programmable; The sign in above table shows fixed item and can not be changed. The sign only shows the factory settings. The sign output can be assigned for plural items. The sign input/output can not be assigned. Either HK output or Cluster ALM output in each channel can be assigned. Note 6: Above Table shows Alarm output matrix for 1+1 configuration Note 7: Only apply to PDH system. Note 8: Only apply to SDH system. Note 9: Only apply to XPIC system. Note 10:Assign to relays 4 to 6 only one category, either pasolink Alarm, House Keeping Control out or Cluster Alarm out.
2-28
ROI-S05748
Output Port condition Interface circuit: Relay Form C Maximum Current: 0.2 A Maximum Voltage: 100 V (AC+DC)
HK-IN1 HK-IN2 HK-IN3 HK-IN4 HK-IN5 HK-IN6 Cluster ALM input1 Cluster ALM input2 Cluster ALM input3 Cluster ALM input4
House keeping Event inport1 House keeping Event inport2 House keeping Event inport3 House keeping Event inport4 House keeping Event inport5 House keeping Event inport6 This item transmits to opposite site. Item 1 This item transmits to opposite site. Item 2 This item transmits to opposite site. Item 3 This item transmits to opposite site. Item 4
Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT Only show PNMT
Input Port condition +3.3 V Normal OPEN (> 200 k ohms) Control CLOSE (< 50 ohms) Interface circuit: photo coupler with bias circuit
+3.3 V
2-29
ROI-S05748
1 2 3 4
Single coaxial cable /50 ohms 5D-FB, 8D-FB (standard), 10D-FB IF signal, alarms, control, monitoring and power source 150 m (5D-FB) 300 m (8D-FB) 350 m (10D-FB) Automatic level equalization 33C to +50C (workable : 40C to +55C)
5 6
Note 1 : In case of employing hitless protection, set each length of two IF cables same or the difference of their cable length shall be less than 100 meters. Note 2 : Salt damage (custom order) In case of operating in the sea or around the coast area (within 3 km from coastline), measure must be taken for the ODU against salt damage. Please contact NEC for the countermeasure. Note 3 : Water Proof N type connector The waterproof N type connectors must be used for IF cable of ODU side, because DC voltage power is supplied in it. Note 4 : IDU IF connector = TNC (Female), ODU IF connector = N (Female) Note 5 : TNC (Male) L-angle connector for the 8D-FB IF cable is used to connect it to the IDU. When the N (Male) straight connector is attached to the 5D-FB or 10D-FB IF cable, the TNC (Male) - N (Female) L-angle adapter is used.
2-30
ROI-S05748
11 - 52 GHz Hybrid
NEC original
NEC original
2-31
ROI-S05748
2.4.1 10 dB Coupler
There are two types of NEC 10 dB Coupler; one is coaxial cable connection type for 6/7/8 GHz bands and the other is ODU Direct Mount type for 11 - 38 GHz Bands. The following 10 dB Coupler is suited for Andrew or RFS Antenna, and all NEC ODUs.
11 - 38 GHz Coupler
* ODU for 6/7/8 GHz: Separate Type * ODU for 11 - 38 GHz: Direct Mount Type * Custom ordered for 28 GHz.
2-32
ROI-S05748
2-33
ROI-S05748
8 GHz
: 7.7
- 8.5
18 GHz
: 17.7
- 19.7
23 GHz
: 21.2
- 23.6
252.04/ 266 340 154/ 161/ 196/ 245 119/ 126/ 151.614/ 154/ 266/ 294.44/ 305.56/ 311.32 530 266 315/ 420/ 470/ 490/ 644/ 728 340/ 750/ 1008/ 1010/ 1092.5/ 1120/ 1250/ 1560 600/ 1008/ 1200/ 1232 855/ 1008/ 1123.5 1008 812 700/ 1000/ 1260/ 616
2-34
ROI-S05748
*2
The DC V to the ODU is supplied through the coaxial cable which is also used for the IF and other signals. The PS circuit on the ODU produces +7/ +8/+9/7/8/9 * and 15 V DC for the component modules from the 48 V DC supplied from the IDU. Note: *: Necessary voltages in the ODU vary depending on the ODU type.
IDU ODU (NEO) MODEM TX IF RX IF SV/CTRL 48 V
ODU INTFC
48 V
TX IF RX IF
DC INPUT
48 V G
PWR
DC-DC CONV
PS +3.6 V 48 V
*2 CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC, E3 INTFC, LAN/WS INTFC, GbE INTFC, For 1+0 Configuration
Notes:
*1: The inner voltages vary depending on the ODU type. *2: Optional For 1+0 Configuration
2-35
ROI-S05748
ODU (NEO)
48 V
TX IF RX IF
DC INPUT
48 V G
PWR
DC-DC CONV
PS +3.6 V 48 V
*2 CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC, E3 INTFC, LAN/WS INTFC, GbE INTFC,
DC INPUT
48 V G
PWR
DC-DC CONV
+3.6 V
ODU (NEO)
TX IF RX IF SV/CTRL 48 V
48 V
TX IF RX IF
MODEM
ODU INTFC
PS 48 V
Notes:
*1: The inner voltages vary depending on the ODU type. *2: Optional For 1+1 Configuration
2-36
ROI-S05748
IDU 20 to 60 V/ +20 to +60 V DC INPUT (+) () SEL V (2/4) (1/3) FUSE FUSE (2) 43 V (1) G OUT
DC-DC CONV
PWR
ODU INTFC
TX IF RX IF SV/CTRL 43 V
43 V
TX IF RX IF
+3.6 V 43 V
MODEM *2 CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC, E3 INTFC, LAN/WS INTFC, GbE INTFC
Notes:
*1: The inner voltages vary depending on the ODU type. *2: Optional For 1+0 Configuration Connecting Other Type Pasolink ODU
2-37
ROI-S05748
2-38 38 pages