1 Lineupforcontrolpanelsfor132kVand33kVshallbeinlinewithSLD Pleasefindproposedlineupenclosed.Finallineupshallbeprovidedinthedetaileddesign. Annunciatorwindowsshallbeprovidedintheexistingannunciatorpanelforthenewfeeders.Incaseofnon availabilityofspacenewannunciationpanelshallbeprovided.Thisshallmatchwiththeexistingpanel.Spare 2 faciasshallbeprovidedforfuturerequirement. 3 Synchronizing Synchronizingsocketsimilartotheexistingoneshallbeprovidedinprotectionpanelsforsynchronizing dependingonavailabilityofsamesocketornewarrangementshallbeproposedwiththetrolley. 4 Raise/lowercommandsandAuto/manualselectionfortapchangingtobeprovided. 5 Parallelingofthreetrafoshallbeprovidedwithnecessaryinterlocks 6 LocalbreakerfailureON/OFFswitchprovisionshallbemadeineachrelaypanelincludingexistingpanel 7 PaintshadeshallbeRAL7032(asperexisting)interiorandexterior Plugsocket(AMPmake)arrangementisprovidedinexistingControlandSCADAinterfacepanelonly.Typeof terminationfornewpanelsshallbeconfirmedbyABBltd.,iftheexistingPlugandsocketisnotavailablenew 8 plugsocketshallbeproposed. 9 Capacitorcontrol&protectionpanel(includingannunciationandmimic)shallbeoffrontaccess. 10 ETandauxtrafotobeincludedinthemimicfornewpanel. 11 MimicsshalbestickerstypeforAmparaSS. Auxvoltagesare48vDC(foundinalarms+Tapchanger),220vDC(forcontrol).Aux.voltagerequirementshall 12 coordinatedwiththeexistingreferencetakenfromCEB 13 CEBrequestedforsimilarswitch(descrepancy,rotary),metersandindicationaspertheexistingpanel. Sincecounterforautotripandmanualtripisnotprovidedinexistingpanelandduetospaceconstraintsame 14 shallnotbeprovidedinAmparaSS.ButthesecoutersshallbeprovidedinValachnaiSS SSS(synchronizingselectorswitch)andAutomanualswitchshallbeprovidedforsynchronizing.Sameshallbe finalizedinthedetaileddesign 15 Auto/reclosingswitchisprovidedintheexistingGISpanelandthesameshallbeprovidedinnewpanelas 16 well. 17 LoadsheddingrelayandloadsheddingON/OFFswitchshallbeprovidedinexistingaswellasnewpanels. 18 ValachnaiSSpanelshallbesuitableforSCADAinterface. 19 ValachnaiSSpanelshallbeconventionalcontrolandBCUcontrol ValachnaiSSSeparateSCADAInterfacepanelshallbeprovidedsimilartoAmparaSS.TobeFreezedasperthe 20 requirement. 21 ValachnaiSS33kVcontrolandprotectionpanelshallbefrontaccess. 22 ValachnaiSS132kVcontrolpanelincludingannunciatorforeachbayshallbefrontaccess. ValachnaiSSMeteringpanelshallbeprovidedseparatelyonefortariffmetering(TRANSCO)andonefor 23 checkmetering(DISCO) 24 Alarmsoundsshallbedifferentincapacitorpanelsandannunciationpanel.
ann.Facia blank
blank
trafo1
b/s1
trafo2
line
blank
blank
blank
f1
t1
b/s2
t2
f4
f5
f6
blank
blank
blank
b/s3
f10
cap3
trafo3
cap1
132kvlineup
33kvlineup
cap2
33kVlineup