Sie sind auf Seite 1von 1

example 1_1+0A station

example 1_1+0_A station Own station TX PWR ALM APC ALM IF INPUT ALM RX LEV ALM ODU CPU ALM IF CABLE ALM MOD ALM MD CPU ALM INPUT LOSS DEM ALM LOF HIGH BER ALM LOW BER ALM OUTPUT LOSS Opposite station HIGH BER ALM LOW BER ALM RX LEV ALM DEM ALM Action

LOF

Note

ODU

TX PWR ALM APC1 ALM or APC2 ALM IF INPUT ALM RX LEV ALM ODU CPU ALM IF CABLE SHORT ALM MOD ALM MD CPU ALM INPUT LOSS DEM ALM LOF HIGH BER ALM LOW BER ALM OUTPUT LOSS

* * *

* *

* * * * * * *

* * *

* * *

** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** **

ie: Pointing, tigten Connector

IDU

* * * * *

* : Original ** : Secondery Note) Secondary alarm may be appeared but not be bound to. Alarm condition table TX PWR ALM APC ALM TX INPUT ALM RX LEVEL ALM ODU CPU ALM IF CABLE ALM MOD ALM CPU(SUB) ALM INPUT LOSS DEM ALM LOF HIGH BER ALM LOW BER ALM OUTPUT LOSS TX power 3 dB down from normal power Auto matic phase control lock off ODU TX IF signal less than -63 dbm RX receiving level less than -82 to -94dBm (TCN tabel depend on bitrate) ODU -IDU communidation failure IDU-ODU cable short circuit Modurator failure Sub CPU failure Baseband signal input loss Demodulator failure Loss of radio frame Signal quality degrade 3E-3/4/5 selectable Signal quality degrade3E-6/7/8/9/Early Warning selectable Baseband signal output loss