Field test form LV Power Circuit Breaker

CUSTOMER: MAADEN K.S.A EQUIPMENT TAG NO.: BI/JO NO.: REF. DRAWINGS & DOCUMENTS: TEST COMPLETION DATE: /08/2010
MAKE TYPE MODEL NO. VL 800 SIEMENS

PROJECT: SUBSTATION-1 DESCRIPTION: L V MCC CIRCUIT BREAKER PLANT NO. / LOCATION:

VOLTAGE RATING CURRENT RATING PLUG RATING

480 Volt A

SECTION 1: MECHANICAL CHECK AND VISUAL INSPECTION:

Item 1 2 3 4 5 6 7 8 9

Description Inspect for physical damage/defects. Check quality of paintwork. Check nameplate information for correctness. Check tightness of all bolted connections (torque wrench method). Check racking mechanism for alignment and smoothness of operation. Check operation of all mechanical interlocks. Check for correct breaker position indication. Check the arc chutes for damage and correct positioning above the interrupter contacts. Check that all control wiring is correct according to the approved drawings and terminal connections are secure.

Remarks OK N.A OK OK OK N.A OK N.A OK

SECTION 2: ELECTRICAL CHECK:

TESTING ENGINEER
Name Signature Date

NOUR QC

MAADEN WITNESS

Field test form LV Power Circuit Breaker

CUSTOMER: MAADEN K.S.A EQUIPMENT TAG NO.: BI/JO NO.: REF. DRAWINGS & DOCUMENTS: TEST COMPLETION DATE: /08/2010
Item 1 2 3 Contact Resistance Description

PROJECT: SUBSTATION-1 DESCRIPTION: L V MCC CIRCUIT BREAKER PLANT NO. / LOCATION:

Remarks OK OK OK

Insulation resistance TRIP TEST

SECTION 3: TEST VALUES:

1. INSULATION RESISTANCE TEST ( VALUES IN MEGA-OHMS) ( TEST VOLTAGE


RESULTS PHASE (BREAKER CLOSED) PHASE

KV DC)
RESULTS (BREAKER CLOSED)

A To ( B+C+G)

A TO B

B to ( A+C+G)

B TO C

C to (A+B+G)

C TO A

TESTING ENGINEER
Name Signature Date

NOUR QC

MAADEN WITNESS

Field test form LV Power Circuit Breaker

CUSTOMER: MAADEN K.S.A EQUIPMENT TAG NO.: BI/JO NO.: REF. DRAWINGS & DOCUMENTS: TEST COMPLETION DATE: /08/2010

PROJECT: SUBSTATION-1 DESCRIPTION: L V MCC CIRCUIT BREAKER PLANT NO. / LOCATION:

2. CONTACT RESISTANCE TEST (VALUES IN MICRO OHMS) : (TEST CURRENT

A)

PHASE

CONTACT RESISTANCE

A
B C

3. TRIP TEST

PHASES PHASE CHECK TRIP CHECK

L1

L2

L3

TESTING ENGINEER
Name Signature Date

NOUR QC

MAADEN WITNESS

Field test form LV Power Circuit Breaker

CUSTOMER: MAADEN K.S.A EQUIPMENT TAG NO.: BI/JO NO.: REF. DRAWINGS & DOCUMENTS: TEST COMPLETION DATE: /08/2010

PROJECT: SUBSTATION-1 DESCRIPTION: L V MCC CIRCUIT BREAKER PLANT NO. / LOCATION:

SECTION 4: TEST EQUIPMENTS LISTING AND CALIBRATION DATA

DEVICE Insulation Resistance Micro Ohm meter TRIP CHECK

MAKE

CALIBRATION DATE

CALIBRATION EXP.

TESTING ENGINEER
Name Signature Date

NOUR QC

MAADEN WITNESS