Sie sind auf Seite 1von 6

Counter

M1006C128
M1006C129
M1006C130
M1006C131
M1006C132
M1006C133
M1006C134
M1006C135
M1006C136
M1006C137
M1006C138
M1006C139
M1006C140
M1006C141
M1006C142
M1006C143
M1006C144
M1006C145
M1006C146
M1006C147
M1006C148

Class
PRACH_DELAY_CLASS_0
PRACH_DELAY_CLASS_1
PRACH_DELAY_CLASS_2
PRACH_DELAY_CLASS_3
PRACH_DELAY_CLASS_4
PRACH_DELAY_CLASS_5
PRACH_DELAY_CLASS_6
PRACH_DELAY_CLASS_7
PRACH_DELAY_CLASS_8
PRACH_DELAY_CLASS_9
PRACH_DELAY_CLASS_10
PRACH_DELAY_CLASS_11
PRACH_DELAY_CLASS_12
PRACH_DELAY_CLASS_13
PRACH_DELAY_CLASS_14
PRACH_DELAY_CLASS_15
PRACH_DELAY_CLASS_16
PRACH_DELAY_CLASS_17
PRACH_DELAY_CLASS_18
PRACH_DELAY_CLASS_19
PRACH_DELAY_CLASS_20

PRACHDelayRange=3
20km range
From (m)
To (m)
0
234
234
468
468
702
702
936
936
1170
1170
1404
1404
2106
2106
2574
2574
3042
3042
3510
3510
3978
3978
4914
4914
6084
6084
7020
7020
7956
7956
9126
9126
10296
10296
12402
12402
14976
14976
17550
17550
infinite
* currently use in cells with
CellRange = 10km

PRACHDelayRange=5
180km range
From (m)
To (m)
0
234
234
468
468
936
936
2106
2106
3042
3042
3978
3978
4914
4914
6084
6084
7956
7956
10062
10062
19890
19890
29952
29952
40014
40014
50076
50076
59904
59904
80028
80028
99918
99918
120042
120042
149994
149994
179946
179946
infinite
* currently use in cells with
CellRange = 60km & 180km

Description: The number of total uplink power (RTWP) measurement report samples in which the power value is inside Class

Updated: This counter is updated periodically according to the RNC internal timer whose period with WBTS is RRIndPeriod an
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS
CLASS

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

CLASS_0
CLASS_1
CLASS_2
CLASS_3
CLASS_4
CLASS_5
CLASS_6
CLASS_7
CLASS_8
CLASS_9
CLASS_10
CLASS_11
CLASS_12
CLASS_13
CLASS_14
CLASS_15
CLASS_16
CLASS_17
CLASS_18
CLASS_19
CLASS_20
CLASS_21

RTWP< -108 dBm


( -108 dBm <=RTWP< -107 dBm)
(-107 dBm <=RTWP< -106 dBm)
(-106 dBm <=RTWP< -105)
(-105 dBm <=RTWP< -104 dBm)
(-104 dBm <=RTWP< -103 dBm)
(-103 dBm <=RTWP< -102 dBm)
(-102 dBm <=RTWP< -101 dBm)
(-101 dBm <=RTWP< -100 dBm)
(-100 dBm <=RTWP< -99 dBm)
(-99 dBm <=RTWP< -98 dBm)
(-98 dBm <=RTWP< -96 dBm)
(-96 dBm <=RTWP< -94 dBm)
(-94 dBm <=RTWP< -92 dBm)
(-92 dBm <=RTWP< -89 dBm)
(-89 dBm <=RTWP< -86 dBm)
(-86 dBm <=RTWP< -83 dBm)
(-83 dBm <=RTWP< -80 dBm)
(-80 dBm <=RTWP< -75 dBm)
(-75 dBm <=RTWP< -70 dBm)
(-70 dBm <=RTWP< -65 dBm)
(-65 dBm <= RTWP)

which the power value is inside Class 0 range (RTWP< -108 dBm). Note: All the received power is taken into account, not just Rel99.

period with WBTS is RRIndPeriod and with NBxxx the period is min(PrxTotalReportPeriod, PtxTotalPeriod). When the timer expires, the R

en into account, not just Rel99.

riod). When the timer expires, the RTWP value is calculated based on the information of the latest received power value in an NBAP: COM

ceived power value in an NBAP: COMMON MEASUREMENT REPORT or NBAP-PRIVATE: RADIO RESOURCE MEASUREMENT REPORT sent by

RCE MEASUREMENT REPORT sent by the BTS, and the reported RTWP value is inside