Beruflich Dokumente
Kultur Dokumente
C
C32
.001 100V
R54
22K
C27
.22 50V
1
D10
47K
1
R53
47K
700mV RMS
TP1
3 1 2
J25
J1
R62
22K
3.8VRMS
C9
1 50V
C30
.0047 100V
R88
22K
C37
.047 100V
TP2
5 7 6
R87
22K
R63
4.7K
C36
1 50V
250mV RMS
TP5
LEVEL
CW
R2
680K
R57
22K
R52 C33
22K
R48
22K
C26
.22 50V
1.15VRMS
PAGE_NEXT
D13
1N914 75V PIV
R3
6.8K
C2
1 50V
R12
22K
1 2 3
J5
P9 R47
47K
CW
TP6
RING
J4
.047 100V
20K RA
R10
220
-16V
+16V C4
100 35V
U3:B
7
TP4
C50
10 35V
JW51 R11
22K
1.15VRMS
TP7
TUNER OUT
J2
R65
100K
C41
4
STYLE S1
CMN
TP3
5 7 6
R15
10K
2
TLO-72
1 3
P8 C45
2.2 50V
100 pF 200V
R32
1K
50K L
CW
U2:B TLO-72
SLVE_SW SLEEVE
56 pF 200V
C42
R64
2.2K
C34
CW
P1
50K L
R45
47K
C25
.22 50V
3 CCW
HIGH
R14
47K
I
SW1
I
U3:A
4.7K
R29
100K
R78
C C
C7
22 50V
1
R81
270
2.2 50V
GAIN R56
47K
R36
22K
CW
P7
50K L
R86
47K
22K
O O 2 3
2
2 1
MID C29
.015 50V
C46
.022 50V
U4:A
R46
22K
C28
.22 50V
CW
P6
50K L
R80
22K
MUTE
NE5532
R76
22K
C48 R82
22K .047 100V
R38
22K
LOW
J24 {Label}
R27
47K
R37
22K
3 1 2
R79
1K
6 5
U4:B
C49
22 50V
R83
270
R51
2.2K
C23
.033 50V
C22
.033 50V
NE5532 R30
22K
U2:A TLO-72
C24
.22 50V
R40
4.7K
R39
100K
TP8
1.1VRMS
NET00098
4a SB 2.5a SB
FUSE CLIP
F1
FC2
{Value}
{Value}
J19 J16
{Value}
R1 +50V
2.2K 1/2W
D1
RED
J18
{Value} {Value} {Value}
+16V1 R5
100
J6
J10 C3
J17 J22
.0033 250V
{Value}
ACV DCV
BR1 R68
KBU1004G
J28
1 2 3
J8
{Value} {Value} {Value}
+16V
5600 80V
J20 C1 J7
{Value}
C6
.1 100V
C19
330 10W
C39
100 35V
C21
.047 100V
C18
.047 100V
22 16V
C5
.047 100V
4
HPGS
C43
6 7 8
J13
{Value} {Value}
.0033 250V
J9
5600 80V
C14
.1 100V
C38
C40
100 35V
J14
{Value} {Value}
J12
22 16V
C8
J15
{Value}
DCV ACV
-50V
330 10W
R9
100
-16V1
5
J13 BLK AC LINE J12 AC LINE AC NEUTRAL BLU/WHT
J13
J17
J16 J7
BLUE WHT
J12 J14
CAUTION: THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL. TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DO NOT PERFORM ANY SERVICING BEYOND THAT EXPLAINED IN THE OPERATING INSTRUCTIONS. NOTES: 1) CAUTION: SHOCK HAZARD!! THIS UNIT CONTAINS HAZARDOUS VOLTAGE. DISCONNECT POWER AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE TOUCHING INTERNAL PARTS. 2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL. CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL. 3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE AND 10 MEGOHM DIGITAL VOLTMETER.
0
REV
1-9-03
CONTROL ISSUE
J11
BROWN
J15
Date
DESCRIPTION
Ecr(s)/Ecn(s)
Chgd By
Appvd by
Date
THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO ST. LOUIS MUSIC, INC
Date:
4/18/00 11880 Borman Drive, St. Louis, MO 63146
First Used On:
J9
VIOLET
AC NEUTRAL
Released:
BA210/115HP D
NONE Drawing Title:
J7
VIOLET
AC NEUTRAL
J7
VIOLET
Plot Date: Thu Jan 09, 2003 Drawing Size: Plot Time: 08:13:03
Tolerance:
07S457-XX H
-50V +50V
D3
1N914 75V PIV
+50V
D5
1N914 75V PIV
R4
680
R8
680
D2
1N914 75V PIV
D4
1N914
D6
1N914 75V PIV
1
R74
.33 10W 5per
+16V R7
3.3K 1/2W 5per 75V PIV
R6
3.3K 1/2W 5per
R34
270
OC1
VTL-5C7
R75
.33 10W 5per
R50
1K
S D
Q2
C31
IRFP-9140R
Q6
J112
G
R59
-16V C44
1 50V 1M
10 35V
Q4
MJE-340
R71
47
C12
33 pF 200V
Q7
IRFP-9140R
C10
33 pF 200V
R23
47K
R28
R41 R25
D S 2 3
1K
R19
33K
220
3.3 1W 5per
TP11
C17
.1 100V
26.3VRMS
U5:A
Q9
G
J112
NE5532
2
R20 HPGS
270K
TP12
L1
800mVRMS
5 7 6
.5 uH
2
J23
2 1
TP10 2.0VRMS
U5:B NE5532
C13
330 pF 100V
R61
1 1W 5per
-16V
R44
4.7K
R35
220
Q3 R26
47
R43
330
MPS-A06 D
R49 J29
1 2 3 4 5
Q1
MJE-350
47
Q5
IRFP-140R
C20
AP1
500 1 50V D
R70
47
BIAS
CW
Q8
IRFP-140R
6 7 8
HPGS
3
-16V
R31
270
3
R72
.33 10W 5per .33 10W 5per
D9 1N4740ARL 10V
R73
-50V
0
CAUTION: THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL. TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DO NOT PERFORM ANY SERVICING BEYOND THAT EXPLAINED IN THE OPERATING INSTRUCTIONS. REV
1-9-03 Date
CONTROL ISSUE
DESCRIPTION
Ecr(s)/Ecn(s)
Chgd By
Appvd by
Date
THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO ST. LOUIS MUSIC, INC
Signatures:
Drawn: RLB Checked: Released:
Plot Date: Thu Jan 09, 2003 Plot Time:
Date:
4/18/00
11880 Borman Drive, St. Louis, MO 63146
4
NOTES: 1) CAUTION: SHOCK HAZARD!! THIS UNIT CONTAINS HAZARDOUS VOLTAGE. DISCONNECT POWER AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE TOUCHING INTERNAL PARTS. 2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL. CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL. 3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE AND 10 MEGOHM DIGITAL VOLTMETER.
BA210/115HP
Drawing Size:
C
NONE 2
Drawing Title:
Tolerance:
07S457-XX
B
W3
5
L2 4
J1
W1 RED WIRE
1
1
J5 B1 C3 4
2 3
J2
J8
4
36V
TO SPEAKERS
B2
J3
112 APC
6
36V
JWOPT1 6 B3
DASH NO
2
J4
TIP TIP_SW SLEEVE
JWOPT2
36V
-04 -05
B4 W2 BLK WIRE
36V
4 C2 4 C1
J6
112 APC
3
J7
L1 4
3
3
7/30/02 ADDED -05 ASSY N00923 REM
WFB WFB
CAUTION: THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL. TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DO NOT PERFORM ANY SERVICING BEYOND THAT EXPLAINED IN THE OPERATING INSTRUCTIONS. NOTES:
2 1 0
4) SEE TABLE FOR VALUES. 5) USED ON DASH 01, 04, -05 ONLY. 6) SEE BOM FOR USAGE
REV
N00727 N00402
Ecr(s)/Ecn(s)
THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO ST. LOUIS MUSIC, INC
Signatures:
Drawn: Checked: Released:
Plot Date: Plot Time: Wed Jul 31, 2002 10:31:07
Date:
RLB 12-13-99 11880 Borman Drive, St. Louis, MO 63146 First Used On:
1) CAUTION: SHOCK HAZARD!! THIS UNIT CONTAINS HAZARDOUS VOLTAGE. DISCONNECT POWER AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE TOUCHING INTERNAL PARTS. 2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL. CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL. 3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE AND 10 MEGOHM DIGITAL VOLTMETER.
PR410
Drawing Size:
A
NONE 1 of
Drawing Title:
CROSSOVER 07S777-XX
Tolerance: