SINGLE PACKAGE COOL-ONLY and COOL-HEAT GAS / ELECTRIC AIR CONDITIONERS


DM 180 & 240 (WORLD 50 HZ)
DM with Gas Heat Shown

SUNLINE 2000
TM

DESCRIPTION
Sunline 2000 units are highly efficient, convertible rooftops. All models have dual refrigerant circuits for efficient part load operation. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. These units are designed and manufactured under ISO 9002 Quality System Certification. Cooling only, cooling with gas heat and cooling with supplemental electric heat units are available with a wide variety of field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails. The base rails have holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. Powder paint cabinets provide an exceptionally durable finish with the 750 hour salt spray process per ASTM-B117 test standard. All models are available with three different outdoor air damper accessosries: All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. A high static drive option is available for applications with a higher CFM and/or static pressure requirement. All compressors include crankcase heat and internal pressure relief. Every refrigerant circuit includes an expansion valve, a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure loss of charge switch. Simplicity Controls - Simplicity control boards have standardized a number of features previously available only as options or by utilizing additional controls.

Low Ambient - An integrated low-ambient control

Single enthalpy economizer Single enthalpy economizer with power exhaust Motorized outdoor air intake damper
All models (including those with an economizer ) are suitable for either downflow or sideflow duct connections. Models with factory installed Power Exhaust are only suitable for bottom duct connections. For downflow duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For sideflow duct, replace the supply and return air panels on the rear of the unit with a side duct flange accessory. A fixed outdoor air intake assembly is shipped in the return air compartment of all units without an economizer or motorized outdoor air damper option. The assembly includes a rain hood with a damper that can be set for 10, 15 or 25% outdoor air. With bottom duct connections, the intake damper assembly should be mounted over the opening in the return air panel. With horizontal ductwork, it should be mounted on the return air duct.

allows all units to operate in the cooling mode down to 0F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a three times, youre out philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor.

036-21483-003-A-0104

On Board Diagnostics - Each alarm will energize

a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power.

The rain hood is painted to match the basic unit and must be field-assembled before installing. Power exhaust is not available as a field installed option. DUAL INPUT ELECTRONIC ENTHALPY CONTROL KIT This kit contains the required components to convert a Single Enthalpy Economizer to Dual Enthalpy. MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in / plug-in damper with a 2-position, spring-return motor actuator which opens to a pre-set position whenever the supply air blower is operating and drives fully closed when the blower shuts down. Power exhaust is not available as a field installed option. BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal air pressure on units with an economizer. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. ROOF CURBS - Roof curbs, 356mm (14 in.) high, provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. They're designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. SIDE DUCT FLANGES - Twenty-five millimeter (1 in.) flanges replace the supply and return air panels on the rear of the unit to accommodate horizontal duct connections. These flanges can also be used individually for bottom supply/horizontal return or horizontal supply/bottom return. HIGH SPEED DRIVE - A smaller blower pulley, a larger motor pulley (including a replacement belt) increase the speed of the supply air blower for applications with a higher airflow and/or static pressure requirement. WOOD SKID - Allows unit to be handled with 90 forks. CO SENSOR - Senses CO levels and automatically overrides the economizer when levels rise above the present limits. COIL GUARD - Helps protect the condenser coil from damage. PHASE MONITORS - Designed to prevent unit damage by shutting the unit down in an out-of-phase condition.

All gas heat models are built with two heating sections for two equal stages of capacity control. Each section includes a durable heat exchanger with aluminized steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive current and temperature by fuses and two thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection in the base pan of the unit or through a knockout in the wiring panel on the front of the unit. All units are now offered with factory mounted BAS Controls. Your options would be Novar, Honeywell, Johnson and CPS. Phenolic Coated Evaporator and Condenser Coils - Special coating process that utilizes Technicoat 10-1 processes. Coating is applied by total immersion of the complete coil for maximum protection.

FIELD-INSTALLED ACCESSORIES
SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

TABLE OF CONTENTS
Description ..........................................................................1 Field-Installed Accessories..................................................2 Product Nomenclature.........................................................3 Ratings ................................................................................8 Cooling Capacities...............................................................9 Blower Performance ..........................................................13 Blower Motor and Drive Data ............................................17 Static Resistances .............................................................17
2

Field Wiring .......................................................................18 Electrical Data - Cooling and Gas Heat.............................18 Electrical Data - Units with Electric Heat ...........................19 Physical Data.....................................................................19 Unit Dimensions ................................................................20 Roof Curb Dimensions ......................................................23 Typical Applications ...........................................................23
Unitary Products Group

036-21483-003-A-0104

Unitary Products Group

036-21483-003-A-0104

PRODUCT NOMENCLATURE 15 & 20 TON Sunline 2000 Model Number Nomenclature


AA AB AC AD AE AF AG AH BA BB BC BD BE BF BG BH CA CB CC CD CE CF CG CH CJ CK CL CM CN CP CQ CR DA DB DC DD DE DF DG DH DJ DK DL DM DN DP DQ DR EA None Phase Monitor Coil Guard Dirty Filter Switch Phase Monitor & Coil Guard Phase Monitor & Dirty Filter Switch Coil Guard & Dirty Filter Switch Phase Monitor, Coil Guard, & Dirty Filter Switch Hinged Filter Door & Tooless Access Panels Phase Monitor, Hinged Filter Door & Tooless Access Panels Coil Guard, Hinged Filter Door & Tooless Access Panels Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Phase Monitor & Coil Guard, Hinged Filter Door & Tooless Access Panels Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Coil Guard & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels CPC Controller with Dirty Filter Switch & Air Proving Switch CPC Controller, DFS, APS & Phase Monitor CPC Controller, DFS, APS & Coil Guard CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Cond. Coil CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. Coil CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard CPC Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels

Unitary Products Group

036-21483-003-A-0104 ADDITIONAL OPTIONS


EB EC ED EE EF EG EH EJ EK EL EM EN EP EQ ER GA GB GC GD GE GF GG GH GJ GK GL GM GN GP GQ GR HA HB HC HD HE HF HG HH HJ HK HL HM HN HP HQ HR JA JB JC Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch Honeywell Excel 10 Controller, DFS, APS & Phase Monitor Honeywell Excel 10 Controller, DFS, APS & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch Johnson UNT Controller, DFS, APS & Phase Monitor Johnson UNT Controller, DFS, APS & Coil Guard

Unitary Products Group

036-21483-003-A-0104 ADDITIONAL OPTIONS


JD JE JF JG JH JJ JK JL JM JN JP JQ JR NA NB NC ND NE NF NG NH NJ NK NL NM NN NP NQ NR PA PB PC PD PE PF PG PH PJ PK PL PM PN PP PQ PR RC TA TB TC TD Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch Novar ETC-3 Controller, DFS, APS & Phase Monitor Novar ETC-3 Controller, DFS, APS & Coil Guard Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Coil Guard and small Made in USA Flag Decal Technicoat Condenser Coil Technicoat Condenser Coil & Phase Monitor Technicoat Condenser Coil & Coil Guard Technicoat Condenser Coil & Dirty Filter Switch

Unitary Products Group

036-21483-003-A-0104

ADDITIONAL OPTIONS
TE TF TG TH TJ TK TL TM TN TP TQ TR TS TT TU TV TW TX TY TZ UA UB UC UD UE UF UG UH UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UY UZ Technicoat Condenser Coil, Phase Monitor, & Coil Guard Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil Technicoat Evaporator Coil & Phase Monitor Technicoat Evaporator Coil & Coil Guard Technicoat Evaporator Coil & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, & Coil Guard Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils Technicoat Evaporator & Condenser Coils & Phase Monitor Technicoat Evaporator & Condenser Coils & Coil Guard Technicoat Evaporator & Condenser Coils & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil & Phase Monitor, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil & Coil Guard, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil & Phase Monitor, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil & Coil Guard, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils & Phase Monitor, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils & Coil Guard, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels

Unitary Products Group

036-21483-003-A-0104

SUNLINE 2000

(OPTION / ACCESS.) UNITS ALUMINIZED STEEL

THROWAWAY

(OPTION / ACCESSORY)

FEMALE

MODEL DM*N
(Gas Heating)

RATINGS
CAPACITY RATINGS - Cooling / Electric Heating
Model Rating Point T1 T2 T3 T1 T2 T3 Total Output, Mbh / kW 159 / 46.6 142 / 41.7 152 / 44.6 210 / 61.5 182 / 53.3 196 / 57.5 Total Input, kW 18.2 20.0 16.4 24.8 27.1 22.2 COP 2.60 2.10 2.75 2.50 2.00 2.60 EER! 8.80 7.15 9.40 8.50 6.75 8.80 Sensible Output, Mbh / kW 132 / 38.7 141 / 41.2 119 / 34.9 176 / 51.5 182 / 53.3 152 / 44.6 Latent Output, Mbh / kW 26.9 / 7.9 1.6 / 0.5 33.2 / 9.7 34.0 / 10.0 0.0 / 0.0 42.6 / 12.5 Electric Heat" Nominal Capacity, kW 18, 36, 54, 72

DM180

DM240


18, 36, 54, 72

T1 = Moderate Climates, T2 = Hot Climates, T3 = Cool Climates. COP = Coefficient of Performance - total output kW divided by the total input kW.

! "

EER = Energy Efficiency Ratio - total output Mbh divided by the total input kW. Heaters available as factory-installed options or field-installed accessories - all with single point power supply.

CAPACITY RATINGS - Gas Heating


Gas Heat Capacity Model DM180N240 DM240N240 Cooling Capacity, Mbh / kW 180 / 52.7 240 / 70.3 Input (Net) Mbh / kW 291 / 85.2 Output Mbh / kW 240 / 170 Gas Rate* cfh / m!/h 302 / 8.5 Temp. Rise (F / C) At Full Input Min. Max. 20 / 11 50 / 28

NOTE: Gas Heaters are shipped available for natural gas, but can be converted to L.P. / propane gas with a field-installed conversion accessory. All gas units are two-stage heating. First stage is 50% of total.

*Based on net input and 2nd. -H family, G20 (methane) net fuel value (9.97 kWh/m!).

Unitary Products Group

036-21483-003-A-0104

COOLING CAPACITIES (m3/s Air Flow) - 180 UNITS


Air On Evaporator Coil m!/s WB C 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 Total Cap. kW 66.4 62.3 58.2 56.7 55.2 61.5 57.7 53.9 52.5 51.1 57.1 53.6 50.1 48.7 47.4 60.7 57.2 53.7 52.3 51.0 56.3 53.1 49.8 48.6 47.3 51.9 48.9 45.9 44.7 43.6 49.6 47.3 45.0 43.6 42.1 49.4 47.2 44.9 43.4 42.0 46.5 44.4 42.3 40.9 39.5 Power Input kW Sensible Capacity, kW Entering Dry Bulb Temp., C 32 30 28 26 @27C Air Temperature on Condenser Coil 14.7 51 44 37 30 14.4 59 52 44 37 14.0 58 58 52 45 14.0 57 57 56 49 13.9 55 55 55 52 14.5 46 40 34 27 14.2 53 46 40 34 13.9 54 53 47 41 13.8 52 52 51 44 13.7 51 51 51 48 14.3 37 32 28 23 14.0 43 38 33 29 13.6 48 44 39 34 13.6 49 47 42 37 13.5 47 47 45 40 @35C Air Temperature on Condenser Coil 15.9 50 43 36 29 15.5 57 50 43 36 15.2 54 54 51 43 15.1 52 52 52 47 15.0 51 51 51 47 15.9 44 38 32 25 15.6 51 44 38 32 15.2 50 50 45 39 15.1 49 49 48 41 15.0 47 47 47 44 15.6 36 31 27 22 15.3 41 37 32 27 14.9 46 42 38 33 14.8 45 45 40 35 14.7 44 44 43 38 @46C Air Temperature on Condenser Coil 18.2 46 39 32 25 17.6 47 46 39 32 17.1 45 45 45 39 17.1 44 44 44 40 17.1 42 42 42 39 17.8 41 35 29 23 17.2 47 42 36 29 16.6 45 45 42 36 16.6 43 43 43 37 16.6 42 42 42 39 17.5 33 29 24 19 17.0 39 34 30 25 16.4 42 40 35 31 16.4 41 41 36 32 16.4 40 40 38 33

24 23 30 38 41 45 21 28 35 38 42 19 24 30 33 36 22 29 36 40 40 19 26 32 35 38 17 23 28 31 33 18 25 32 33 31 17 23 30 31 33 15 20 26 27 28

22 23 31 34 37 22 28 32 35 19 25 28 31 22 29 32 33 20 26 29 32 18 24 26 29 18 25 26 24 17 24 25 27 16 21 22 24

3.40

2.80

2.10

3.40

2.80

2.10

3.40

2.80

2.10

 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.

These ratings include the condenser fan motors (Total 2.1 kW) and the compressor motors but not the supply air blower motor.

Unitary Products Group

036-21483-003-A-0104

COOLING CAPACITIES (CFM Air Flow) - 180 UNITS


Air On Evaporator Coil CFM WB F 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 Total Cap. MBH 227 213 199 193 188 210 197 184 179 174 195 183 171 166 162 207 195 183 179 174 192 181 170 166 161 177 167 157 153 149 169 161 154 149 144 169 161 153 148 143 159 151 144 139 135 Power Input kW Sensible Capacity, MBH Entering Dry Bulb Temp., F 90 86 82 79 @80F Air Temperature on Condenser Coil1 14.7 175 151 126 102 14.4 200 176 152 127 14.0 199 199 177 153 14.0 193 193 190 166 13.9 188 188 188 176 14.5 157 136 115 93 14.2 180 159 138 116 13.9 184 182 160 139 13.8 179 179 172 151 13.7 174 174 174 163 14.3 127 111 95 79 14.0 146 130 114 98 13.6 165 149 133 117 13.6 166 159 143 127 13.5 162 162 153 137 @95F Air Temperature on Condenser Coil 15.9 170 146 122 98 15.5 195 171 147 123 15.2 183 183 172 148 15.1 179 179 179 159 15.0 174 174 174 162 15.9 150 129 108 87 15.6 172 151 130 109 15.2 170 170 153 132 15.1 166 166 162 141 15.0 161 161 161 151 15.6 123 107 91 75 15.3 142 126 110 94 14.9 157 145 129 113 14.8 153 153 137 121 14.7 149 149 145 129 @115F Air Temperature on Condenser Coil 18.2 157 133 109 85 17.6 161 158 134 110 17.1 154 154 154 135 17.1 149 149 149 137 17.1 144 144 144 132 17.8 141 120 99 78 17.2 161 142 121 100 16.6 153 153 144 123 16.6 148 148 148 128 16.6 143 143 143 133 17.5 114 98 82 66 17.0 133 117 101 85 16.4 144 136 120 104 16.4 139 139 124 108 16.4 135 135 128 112 75 78 103 128 142 152 72 95 118 130 142 63 82 101 111 121 74 99 124 135 138 66 88 110 120 130 59 78 97 105 113 61 85 110 112 107 57 79 102 107 112 50 69 88 92 96 72 79 104 117 128 74 97 109 121 66 86 96 105 75 100 111 113 67 89 99 109 62 81 89 97 61 86 88 83 58 81 86 90 53 72 76 80

7200

5930

4450

7200

5930

4450

7200

5930

4450

 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.

These ratings include the condenser fan motors (Total 2.1 kW) and the compressor motors but not the supply air blower motor.

10

Unitary Products Group

036-21483-003-A-0104

COOLING CAPACITIES (m3/s Air Flow) - 240 UNITS


Air On Evaporator Coil m!/s WB C 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 23 21 19 17 15 Total Cap. kW 80.4 77.6 74.8 72.4 70.0 76.9 74.3 71.6 69.3 67.0 71.2 68.7 66.3 64.1 62.0 74.9 72.3 69.8 67.4 65.0 71.3 68.9 66.4 64.2 61.9 65.4 63.1 60.9 58.8 56.7 66.4 63.3 60.2 59.0 57.8 63.8 60.8 57.8 56.7 55.5 59.4 56.6 53.8 52.8 51.7 Power Input kW Sensible Capacity, kW Entering Dry Bulb Temp., C 32 30 28 26 @27C Air Temperature on Condenser Coil 19.0 74 65 55 46 18.8 78 70 61 52 18.6 75 75 67 57 18.4 72 72 71 62 18.1 70 70 70 65 18.8 68 60 52 44 18.6 73 65 57 49 18.4 72 70 62 54 18.2 69 69 67 59 17.9 67 67 67 63 18.5 56 50 44 37 18.3 60 54 48 42 18.1 65 59 52 46 17.9 64 62 56 50 17.6 62 62 60 54 @35C Air Temperature on Condenser Coil 21.0 71 61 52 43 20.7 72 68 58 49 20.4 70 70 65 55 20.1 67 67 67 58 19.9 65 65 65 60 20.7 65 57 49 41 20.5 69 62 54 46 20.2 66 66 60 52 19.9 64 64 63 55 19.7 62 62 62 58 20.4 52 46 40 34 20.1 57 51 45 39 19.8 61 56 50 44 19.6 59 58 52 46 19.3 57 57 54 48 @46C Air Temperature on Condenser Coil 23.4 65 56 47 38 22.9 63 62 53 44 22.3 60 60 60 51 22.3 59 59 59 53 22.2 58 58 58 53 23.3 60 52 44 36 22.7 61 58 50 42 22.2 58 58 56 48 22.1 57 57 57 50 22.1 56 56 56 52 23.1 49 42 36 30 22.5 54 47 41 35 22.0 54 53 46 40 21.9 53 53 48 42 21.9 52 52 49 43

24 37 43 48 53 56 36 41 46 51 55 31 36 40 44 47 34 40 46 49 51 33 38 44 47 50 28 33 38 40 42 29 35 41 43 44 28 34 40 42 44 24 29 34 36 37

22 33 39 44 47 33 38 43 47 30 34 38 41 31 37 40 42 30 36 39 42 27 31 34 36 26 32 34 35 26 32 34 35 23 28 30 31

4.40

3.80

2.80

4.40

3.80

2.80

4.40

3.80

2.80

 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.

These ratings include the condenser fan motors (Total 2.1 kW) and the compressor motors but not the supply air blower motor.

Unitary Products Group

11

036-21483-003-A-0104

COOLING CAPACITIES (CFM Air Flow) - 240 UNITS


Air On Evaporator Coil CFM WB F 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 73 70 66 63 59 Total Cap. MBH 274 265 255 247 239 263 253 244 236 229 243 234 226 219 212 256 247 238 230 222 243 235 227 219 211 223 215 208 201 193 226 216 205 201 197 218 207 197 193 189 203 193 184 180 176 Power Input kW Sensible Capacity, MBH Entering Dry Bulb Temp., F 90 86 82 79 @80F Air Temperature on Condenser Coil 19.0 252 221 189 158 18.8 265 240 208 177 18.6 255 255 227 196 18.4 247 247 243 211 18.1 239 239 239 223 18.8 232 205 177 150 18.6 250 222 195 168 18.4 244 240 213 186 18.2 236 236 228 200 17.9 229 229 229 215 18.5 191 170 149 128 18.3 206 185 164 143 18.1 221 200 179 158 17.9 219 212 191 170 17.6 212 212 204 183 @95F Air Temperature on Condenser Coil 21.0 241 209 178 147 20.7 247 230 199 168 20.4 238 238 220 189 20.1 230 230 230 199 19.9 222 222 222 206 20.7 221 193 166 139 20.5 235 213 186 158 20.2 227 227 206 178 19.9 219 219 215 188 19.7 211 211 211 197 20.4 179 158 137 116 20.1 195 174 153 133 19.8 208 191 170 149 19.6 201 199 178 157 19.3 193 193 186 165 @115F Air Temperature on Condenser Coil 23.4 223 191 160 129 22.9 216 213 182 151 22.3 205 205 204 172 22.3 201 201 201 179 22.2 197 197 197 182 23.3 204 177 149 122 22.7 207 197 170 142 22.2 197 197 190 163 22.1 193 193 193 169 22.1 189 189 189 176 23.1 166 145 124 103 22.5 183 162 141 120 22.0 184 179 158 137 21.9 180 180 164 143 21.9 176 176 169 148 75 127 146 164 180 192 123 141 158 173 188 107 122 137 149 162 115 136 157 168 175 111 131 151 161 170 95 112 128 136 144 97 119 141 148 150 95 115 136 142 148 82 99 116 122 127 72 114 133 149 161 113 131 146 160 101 116 128 141 105 126 136 143 104 124 133 143 91 107 115 123 88 110 117 119 88 108 115 121 78 95 101 106

9320

8050

5930

9320

8050

5930

9320

8050

5930

 These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor.

These ratings include the condenser fan motors (Total 2.1 kW) and the compressor motors but not the supply air blower motor.

12

Unitary Products Group

036-21483-003-A-0104

BLOWER PERFORMANCE (DM180 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS


STANDARD DRIVE (m3 /s)
BLOWER SPEED, RPM 845 885 925 960 1000 1040 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.10 m!/s Output (kW) 1.8 1.9 2.0 2.1 2.3 2.4 2.45 m!/s Output (kW) 2.2 2.3 2.4 2.6 2.7 2.9 AIRFLOW 2.80 m!/s ESP Output Input (Pa) (kW) (kW) 83 2.6 3.1 115 2.7 3.3 149 2.9 3.4 182 3.0 3.6 222 3.2 3.8 264 3.3 4.0 3.10 m!/s Output (kW) 3.0 3.1 3.3 3.4 3.6 3.8 3.40 m!/s Output (kW) 3.8 4.0 4.2

ESP (Pa) 173 208 245 281 323 369

Input (kW) 2.2 2.3 2.4 2.6 2.7 2.9

ESP (Pa) 138 172 208 242 283 327

Input (kW) 2.6 2.8 2.9 3.1 3.2 3.4

ESP (Pa) 18 49 82 114 152 193

Input (kW) 3.5 3.7 3.9 4.1 4.3 4.5

ESP (Pa) 30 67 107

Input (kW) 4.6 4.8 5.1

HIGH SPEED DRIVE (m3 /s)


BLOWER SPEED, RPM 1030 1070 1115 1155 1200 1240 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.10 m!/s Output (kW) 2.4 2.5 2.7 2.9 3.1 3.3 2.45 m!/s Output Input (kW) (kW) 2.8 3.4 3.0 3.6 3.2 3.8 3.4 4.0 3.6 4.3 3.8 4.5 AIRFLOW 2.80 m!/s ESP Output Input (Pa) (kW) (kW) 253 3.3 3.9 298 3.5 4.2 351 3.7 4.4 401 3.9 4.7 461 4.1 5.0 3.10 m!/s ESP Output Input (Pa) (kW) (kW) 183 3.7 4.5 226 3.9 4.7 278 4.2 5.0 3.40 m!/s ESP Output Input (Pa) (kW) (kW) 97 4.2 5.0 -

ESP (Pa) 357 405 461 514 577 636

Input (kW) 2.8 3.0 3.2 3.4 3.7 3.9

ESP (Pa) 316 362 416 468 529 587

STANDARD DRIVE (CFM)


MOTOR BLOWER PULLEY SPEED, (TURNS RPM OPEN)* 845 6.0 885 5.0 925 4.0 960 3.0 1000 2.0 1040 1.0 4450 CFM ESP Output Input (iwg) (bhp) (kW) 0.7 2.4 2.2 0.8 2.6 2.3 1.0 2.7 2.4 1.1 2.9 2.6 1.3 3.0 2.7 1.5 3.2 2.9 5190 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 2.9 2.6 0.7 3.1 2.8 0.8 3.3 2.9 1.0 3.4 3.1 1.1 3.6 3.2 1.3 3.8 3.4 AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 3.5 3.1 0.5 3.7 3.3 0.6 3.8 3.4 0.7 4.0 3.6 0.9 4.2 3.8 1.1 4.5 4.0 6565 CFM Output Input (bhp) (kW) 4.0 3.5 4.2 3.7 4.4 3.9 4.6 4.1 4.8 4.3 5.1 4.5 7200 CFM Output Input (bhp) (kW) 5.2 4.6 5.4 4.8 5.7 5.1

ESP (iwg) 0.1 0.2 0.3 0.5 0.6 0.8

ESP (iwg) 0.1 0.3 0.4

HIGH SPEED DRIVE (CFM)


BLOWER SPEED, RPM 1030 1070 1115 1155 1200 1240
NOTES:

MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0

4450 CFM ESP Output Input (iwg) (bhp) (kW) 1.4 3.2 2.8 1.6 3.4 3.0 1.9 3.6 3.2 2.1 3.9 3.4 2.3 4.1 3.7 2.6 4.4 3.9

5190 CFM ESP Output Input (iwg) (bhp) (kW) 1.3 3.8 3.4 1.5 4..0 3.6 1.7 4.3 3.8 1.9 4.5 4.0 2.1 4.8 4.3 2.4 5.1 4.5

AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.0 4.4 3.9 1.2 4.7 4.2 1.4 5.0 4.4 1.6 5.2 4.7 1.8 5.5 5.0 -

6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.7 5.0 4.5 0.9 5.3 4.7 1.1 5.6 5.0 -

7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.4 5.6 5.0 -

1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open.

Unitary Products Group

13

036-21483-003-A-0104

BLOWER PERFORMANCE (DM240 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS


STANDARD DRIVE (m 3/s)
BLOWER SPEED, RPM 765 795 820 850 875 905 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.80 m!/s Output (kW) 2.9 3.0 3.1 3.3 3.4 3.6 3.30 m!/s Output Input (kW) (kW) 2.9 3.3 3.1 3.5 3.2 3.7 3.4 3.9 3.6 4.1 3.8 4.3 AIRFLOW 3.80 m!/s ESP Output Input (Pa) (kW) (kW) 23 3.2 3.7 62 3.4 3.9 95 3.6 4.1 136 3.8 4.4 170 4.0 4.6 212 4.3 4.9 4.10 m!/s Output Input (kW) (kW) 4.0 4.5 4.2 4.8 4.4 5.0 4.7 5.3 4.40 m!/s Output Input (kW) (kW) 4.7 5.3 4.9 5.6 5.2 5.9

ESP (Pa) 137 176 209 250 284 327

Input (kW) 3.3 3.4 3.6 3.8 3.9 4.1

ESP (Pa) 93 132 165 206 240 283

ESP (Pa) 40 81 115 157

ESP (Pa) 16 51 93

HIGH SPEED DRIVE (m3 /s)


BLOWER SPEED, RPM 895 930 970 1005 1045 1080 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.80 m!/s Output (kW) 3.5 3.7 4.0 4.2 4.4 4.6 3.30 m!/s Output Input (kW) (kW) 3.7 4.3 4.0 4.5 4.2 4.9 4.5 5.1 4.8 5.5 5.0 5.8 AIRFLOW 3.80 m!/s ESP Output Input (Pa) (kW) (kW) 198 4.2 4.8 248 4.5 5.1 306 4.8 5.5 359 5.1 5.8 420 5.4 6.2 475 5.7 6.5 4.10 m!/s Output Input (kW) (kW) 4.6 5.2 4.9 5.6 5.2 6.0 5.6 6.4 5.9 6.8 6.2 7.1 4.40 m!/s Output Input (kW) (kW) 5.1 5.8 5.4 6.2 5.8 6.6 6.1 7.0 -

ESP (Pa) 312 362 421 473 535 590

Input (kW) 4.0 4.3 4.5 4.8 5.0 5.3

ESP (Pa) 268 318 377 429 491 546

ESP (Pa) 143 193 252 304 365 420

ESP (Pa) 79 129 187 240 -

STANDARD DRIVE (CFM)


BLOWER SPEED, RPM 765 795 820 850 875 905 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 3.8 3.3 0.7 4.0 3.4 0.8 4.2 3.6 1.0 4.4 3.8 1.1 4.6 3.9 1.3 4.8 4.1 6990 CFM ESP Output Input (iwg) (bhp) (kW) 0.4 3.9 3.3 0.5 4.1 3.5 0.7 4.4 3.7 0.8 4.6 3.9 1.0 4.8 4.1 1.1 5.1 4.3 AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 4.3 3.7 0.2 4.6 3.9 0.4 4.8 4.1 0.5 5.1 4.4 0.7 5.4 4.6 0.9 5.7 4.9 8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.2 5.3 4.5 0.3 5.6 4.8 0.5 5.9 5.0 0.6 6.3 5.3 9320 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 6.2 5.3 0.2 6.6 5.6 0.4 6.9 5.9

HIGH SPEED DRIVE (CFM)


BLOWER SPEED, RPM 895 930 970 1005 1045 1080
NOTES:

MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0

5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.3 4.7 4.0 1.5 5.0 4.3 1.7 5.3 4.5 1.9 5.6 4.8 2.1 5.9 5.0 2.4 6.2 5.3

6990 CFM ESP Output Input (iwg) (bhp) (kW) 1.1 5.0 4.3 1.3 5.3 4.5 1.5 5.7 4.9 1.7 6.0 5.1 2.0 6.4 5.5 2.2 6.8 5.8

AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 5.6 4.8 1.0 6.0 5.1 1.2 6.4 5.5 1.4 6.8 5.8 1.7 7.3 6.2 1.9 7.7 6.5

8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 6.1 5.2 0.8 6.6 5.6 1.0 7.0 6.0 1.2 7.4 6.4 1.5 7.9 6.8 1.7 8.4 7.1

9320 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 6.8 5.8 0.5 7.2 6.2 0.8 7.8 6.6 1.0 8.2 7.0 -

1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open.

14

Unitary Products Group

036-21483-003-A-0104

BLOWER PERFORMANCE (DM180N240 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS


STANDARD DRIVE (m3 /s)
BLOWER SPEED, RPM 845 885 925 960 1000 1040 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.10 m!/s Output (kW) 1.8 1.9 2.0 2.1 2.2 2.3 2.45 m!/s Output Input (kW) (kW) 2.0 2.5 2.2 2.6 2.3 2.7 2.4 2.9 2.6 3.1 2.7 3.3 AIRFLOW 2.80 m!/s ESP Output Input (Pa) (kW) (kW) 80 2.4 2.8 117 2.5 3.0 155 2.7 3.2 189 2.8 3.4 228 3.0 3.6 268 3.2 3.9 3.10 m!/s Output Input (kW) (kW) 2.7 3.2 2.9 3.4 3.1 3.7 3.2 3.9 3.5 4.2 3.7 4.4 3.40 m!/s Output Input (kW) (kW) 3.5 4.2 3.7 4.5 4.0 4.8 4.3 5.1

ESP (Pa) 206 242 278 311 349 387

Input (kW) 2.2 2.3 2.4 2.5 2.6 2.8

ESP (Pa) 146 183 220 253 292 331

ESP (Pa) 18 56 94 128 168 209

ESP (Pa) 28 63 103 144

HIGH SPEED DRIVE (m3 /s)


BLOWER SPEED, RPM 1030 1070 1115 1155 1200 1240 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.10 m!/s Output (kW) 2.3 2.4 2.6 2.8 3.0 3.2 2.45 m!/s Output Input (kW) (kW) 2.7 3.2 2.9 3.4 3.1 3.7 3.3 4.0 3.6 4.3 3.8 4.6 AIRFLOW 2.80 m!/s ESP Output Input (Pa) (kW) (kW) 258 3.2 3.8 299 3.4 4.1 345 3.7 4.4 387 3.9 4.7 435 4.2 5.0 3.10 m!/s ESP Output Input (Pa) (kW) (kW) 199 3.6 4.4 240 3.9 4.7 286 4.2 5.0 3.40 m!/s ESP Output Input (Pa) (kW) (kW) 134 4.2 5.0 -

ESP (Pa) 378 417 461 502 548 590

Input (kW) 2.7 2.9 3.1 3.3 3.6 3.8

ESP (Pa) 321 361 407 448 495 538

STANDARD DRIVE (CFM)


MOTOR BLOWER PULLEY SPEED, (TURNS RPM OPEN)* 845 6.0 885 5.0 925 4.0 960 3.0 1000 2.0 1040 1.0 4450 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 2.5 2.2 1.0 2.6 2.3 1.1 2.7 2.4 1.2 2.8 2.5 1.4 2.9 2.6 1.6 3.1 2.8 5190 CFM ESP Output Input (iwg) (bhp) (kW) 0.6 2.7 2.5 0.7 2.9 2.6 0.9 3.1 2.7 1.0 3.2 2.9 1.2 3.4 3.1 1.3 3.7 3.3 AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 3.2 2.8 0.5 3.4 3.0 0.6 3.6 3.2 0.8 3.8 3.4 0.9 4.0 3.6 1.1 4.3 3.9 6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 3.6 3.2 0.2 3.8 3.4 0.4 4.1 3.7 0.5 4.3 3.9 0.7 4.7 4.2 0.8 5.0 4.4 7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 4.7 4.2 0.3 5.0 4.5 0.4 5.3 4.8 0.6 5.7 5.1

HIGH SPEED DRIVE (CFM)


BLOWER SPEED, RPM 1030 1070 1115 1155 1200 1240
NOTES:

MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0

4450 CFM ESP Output Input (iwg) (bhp) (kW) 1.5 3.1 2.7 1.7 3.3 2.9 1.9 3.5 3.1 2.0 3.7 3.3 2.2 4.0 3.6 2.4 4.3 3.8

5190 CFM ESP Output Input (iwg) (bhp) (kW) 1.3 3.6 3.2 1.4 3.8 3.4 1.6 4.1 3.7 1.8 4.4 4.0 2.0 4.8 4.3 2.2 5.1 4.6

AIRFLOW 5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.0 4.3 3.8 1.2 4.5 4.1 1.4 4.9 4.4 1.6 5.2 4.7 1.7 5.6 5.0 -

6565 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 4.9 4.4 1.0 5.2 4.7 1.2 5.6 5.0 -

7200 CFM ESP Output Input (iwg) (bhp) (kW) 0.5 5.6 5.0 -

1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open.

Unitary Products Group

15

036-21483-003-A-0104

BLOWER PERFORMANCE (DM240N240 UNIT SUPPLY AIR) w/DOWNFLOW DUCT APPLICATIONS


STANDARD DRIVE (m /s)
BLOWER SPEED, RPM 765 795 820 850 875 905 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 2.80 m!/s Output (kW) 2.1 2.3 2.4 2.5 2.7 2.8 3.30 m!/s Output Input (kW) (kW) 2.7 3.1 2.9 3.3 3.0 3.4 3.2 3.7 3.4 3.8 3.6 4.1 AIRFLOW 3.80 m!/s ESP Output Input (Pa) (kW) (kW) 50 3.9 4.5 85 4.1 4.7 128 4.3 5.0 4.10 m!/s ESP Output Input (Pa) (kW) (kW) 37 4.8 5.5 4.40 m!/s ESP Output Input (Pa) (kW) (kW) 3

ESP (Pa) 202 238 268 305 336 347

Input (kW) 2.4 2.6 2.7 2.9 3.0 3.2

ESP (Pa) 80 117 150 189 222 262

HIGH SPEED DRIVE (m3 /s)


BLOWER SPEED, RPM 895 925 955 990 1020 1050 1080 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 0.0 2.80 m!/s Output (kW) 2.8 2.9 3.1 3.3 3.5 3.7 3.9 3.30 m!/s Output Input (kW) (kW) 3.5 4.0 3.7 4.2 3.9 4.4 4.1 4.7 4.3 5.0 4.6 5.2 4.8 5.5 AIRFLOW 3.80 m!/s ESP Output Input (Pa) (kW) (kW) 114 4.3 4.9 157 4.5 5.1 201 4.7 5.4 254 5.0 5.7 299 5.2 6.0 346 5.5 6.3 393 5.8 6.6 4.10 m!/s ESP Output Input (Pa) (kW) (kW) 22 4.7 5.4 66 5.0 5.7 112 5.2 6.0 166 5.5 6.3 213 5.8 6.7 261 6.1 7.0 310 6.4 7.3 4.40 m!/s ESP Output Input (Pa) (kW) (kW) 15 5.8 6.6 70 6.1 7.0 119 6.4 7.3 -

ESP (Pa) 361 400 439 486 527 569 612

Input (kW) 3.2 3.4 3.6 3.8 4.0 4.2 4.4

ESP (Pa) 249 290 332 381 425 469 514

STANDARD DRIVE (CFM)


BLOWER SPEED, RPM 765 795 820 850 875 905 MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 5930 CFM ESP Output Input (iwg) (bhp) (kW) 0.8 2.8 2.4 1.0 3.0 2.6 1.1 3.2 2.7 1.2 3.4 2.9 1.3 3.6 3.0 1.5 3.8 3.2 6990 CFM ESP Output Input (iwg) (bhp) (kW) 0.3 3.6 3.1 0.5 3.8 3.3 0.6 4.0 3.4 0.8 4.3 3.7 0.9 4.5 3.8 1.1 4.8 4.1 AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.2 5.3 4.5 0.3 5.5 4.7 0.5 5.8 5.0 8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 6.5 5.5 9320 CFM ESP Output Input (iwg) (bhp) (kW) -

HIGH SPEED DRIVE (CFM)


BLOWER SPEED, RPM 895 925 955 990 1020 1050 1080
NOTES:

MOTOR PULLEY (TURNS OPEN)* 6.0 5.0 4.0 3.0 2.0 1.0 0.0

5930 CFM ESP Output Input (iwg) (bhp) (kW) 1.5 3.7 3.2 1.6 3.9 3.4 1.8 4.2 3.6 2.0 4.4 3.8 2.1 4.7 4.0 2.3 4.9 4.2 2.5 5.2 4.4

6990 CFM ESP Output Input (iwg) (bhp) (kW) 1.0 4.7 4.0 1.2 4.9 4.2 1.3 5.2 4.4 1.5 5.5 4.7 1.7 5.8 5.0 1.9 6.1 5.2 2.1 6.4 5.5

AIRFLOW 8050 CFM ESP Output Input (iwg) (bhp) (kW) 0.5 5.7 4.9 0.6 6.0 5.1 0.8 6.3 5.4 1.0 6.7 5.7 1.2 7.0 6.0 1.4 7.4 6.3 1.6 7.7 6.6

8685 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 6.3 5.4 0.3 6.7 5.7 0.4 7.0 6.0 0.7 7.4 6.3 0.9 7.8 6.7 1.0 8.2 7.0 1.2 8.5 7.3

9320 CFM ESP Output Input (iwg) (bhp) (kW) 0.1 7.8 6.6 0.3 8.2 7.0 0.5 8.6 7.3 -

1. Blower performance values include fixed outdoor air, a dry indoor coil, the standard unit filters and no electric heat. 2. Refer to Page 12 for the resistance values for all other unit options or applications. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. *Do NOT close pulley below minimum turns open.

16

Unitary Products Group

036-21483-003-A-0104

BLOWER MOTOR AND DRIVE DATA


UNIT SIZE MOTOR BLOWER RANGE FRAME EFF. (RPM) kW/HP SIZE (%) 180 845-1040 3.7 / 5.0 240 765-905 5.6 / 7.5 184T 213T 184T 213T 84 87 84 87 ADJUSTABLE MOTOR PULLEY PITCH BORE DESIGDIA. (mm/in.) NATION (mm/in.) 109-135 29 / 1 & 1VP56 4.3-5.3 140-165 35 / 1! & 1VP68 5.5-6.5 124-150 29 / 1 & 1VP62 4.9-5.9 147-178 35 / 1! & 1VP75 5.8-7.0 FIXED BELT (NOTCHED) BLOWER PULLEY PITCH PITCH BORE DESIGDESIGDIA. LENGTH QTY (mm/in.) NATION NATION (mm / in.) (mm/in.) 188 / 7.4 264 / 10.4 175 / 6.9 239 / 9.4 25 / 1 30 / 1!$ 25 / 1 30 / 1!$ BK80 1773 / 69.8 BX68 BX81 BX68 BX81 1 1 1 1

STD. DRIVE

BK110 2103 / 82.8 BK75 1773 / 69.8

HIGH 180 1030-1240 3.7 / 5.0 SPEED DRIVE 240 895-1080 5.6 / 7.5


BK100 2103 / 82.8

All motors are totally enclosed, fan cooled (TEFC), 1450 RPM with solid bases and a 1.15 service factor. Do NOT close this pulley below the minimum number of turns open.

STATIC RESISTANCES*
EXTERNAL STATIC PRESSURE DROP RESISTANCE, Pa/IWG DESCRIPTION 2.1 / 4500 WET COIL 18 kW ELECTRIC HEAT OPTIONS 36 kW 54 kW 72 kW ECONOMIZER OPTION HORIZONTAL DUCT CONNECTIONS 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 50.0 / 0.2 50.0 / 0.2 24.8 / 0.1 50.0 / 0.2 M!/S / CFM MODEL 180 2.8 / 6000 24.8 / 0.1 24.8 / 0.1 50.0 / 0.2 74.4 / 0.3 99.2 / 0.4 24.8 / 0.1 74.4 / 0.3 3.4 / 7200 24.8 / 0.1 24.8 / 0.1 74.4 / 0.3 99.2 / 0.4 149.0 / 0.6 24.8 / 0.1 124.0 / 0.5 2.8 / 6000 24.8 / 0.1 24.8 / 0.1 24.8 / 0.1 50.0 / 0.2 50.0 / 0.2 24.8 / 0.1 50.0 / 0.2 MODEL 240 3.8 / 8000 24.8 / 0.1 24.8 / 0.1 50.0 / 0.2 74.4 / 0.3 99.2 / 0.4 24.8 / 0.1 74.4 / 0.3 4.4 / 9400 24.8 / 0.1 24.8 / 0.1 74.4 / 0.3 99.2 / 0.4 149.0 / 0.6 24.8 / 0.1 124.0 / 0.5

* Deduct these resistance values from the available unit ESP values listed in the respective blower performance table except for Horizontal Duct Connections. Add the Horizontal Duct Connection values due to less airflow resistance.

Unitary Products Group

17

036-21483-003-A-0104

FIELD WIRING - SIMPLICITY CONTROL WIRING DIAGRAM

THERMOSTAT TERMINALS

W1 W2 Y1 Y2 G R C
4

CONTROL TERMINAL BLOCK

RC OCC 5 X 6

W1 W2 Y1 G OCC P P1 Y2 X R SD C

Smoke Detector

R SD SD C

Jumper 3 24 VAC Class 2

TERMINALS ON A LIMITED NUMBER OF THERMOSTATS


1 2 3 4 5 6

Second stage heating not required on single stage heating units. Second stage cooling not required on single stage cooling units. Jumper is required if there is no Smoke Detector circuit. Jumper is required for any combination of R, RC, or RH. OCC is an output from the thermostat to indicate the Occupied condition. X is an input to the thermostat to display Error Status conditions.

ELECTRICAL DATA - Cooling Only Units and Units With Gas Heat
UNIT SIZE 180 240
NOTES:

POWER SUPPLY 380/415-3-50 380/415-3-50

COMPRESSOR RLA #1 #2 19.2 9.6 19.2 19.2 LRA #1 #2 132 66 132 132

SUPPLY AIR OUTDOOR BLOWER FAN MOTOR, (FLA) MOTOR, (#1 & #2) 3.7 kW 5.6 kW FLA, EACH 5 HP 7.5 HP 2.1 8.6 2.1 11.7

TOTAL UNIT AMPACITY, (AMPS) 3.7 kW 5.6 kW 5 HP 7.5 HP 44.0 57.2

MAX. FUSE SIZE 50 60

MIN. WIRE SIZE , (mm /AWG) 10 / 8 16 / 6

1. Slow blow type fuse. 2. Based on 105C insulated copper conductors in conduit.

18

Unitary Products Group

036-21483-003-A-0104

ELECTRICAL DATA - Units With Supplemental Electric Heating


UNIT SIZE POWER SUPPLY (VOLTS) HEATER OPTION MODEL E018 E036 E054 E072 E018 E036 E054 E072 E018 E036 E054 E072 E018 E036 E054 E072 OUTPUT kW 11.3 22.6 33.8 45.1 13.5 26.9 40.4 53.8 11.3 22.6 33.8 45.1 13.5 26.9 40.4 53.8 STAGES 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 AMPS 17.1 34.3 51.4 68.6 18.7 37.4 56.2 74.9 17.1 34.3 51.4 68.6 18.7 37.4 56.2 74.9 MINIMUM CIRCUIT AMPACITY (AMPS) 44.0 53.7 74.9 96.4 44.0 57.5 81.0 85.6 57.2 57.5 78.8 100.3 57.5 61.2 84.6 89.2 MAXIMUM FUSE SIZE 50 60 80 100 50 60 90 100 60 60 80 110 60 70 90 100 MINIMUM WIRE SIZE (mm /AWG) 10 / 8 16 / 6 25 / 4 35 / 2 10 / 8 16 / 6 25 / 4 35 / 2 16 / 6 16 / 6 25 / 4 35 / 2 16 / 6 16 / 6 25 / 4 50 / 2

380-3-50 180 415-3-50

380-3-50 240 415-3-50


NOTES:

1. Slow blow type fuse. 2. Based on 105C copper conductors.

PHYSICAL DATA
COMPONENT DESCRIPTION SUPPLY AIR BLOWER INDOOR COIL OUTDOOR FANS
(Two Per Unit)

CENTRIFUGAL BLOWER FAN MOTOR ROWS DEEP FINS PER 25mm (1 in.) FACE AREA PROPELLER DIA. FAN MOTOR NOMINAL AIRFLOW

DIA. x WD. (mm) DIA. x WD. (in.) kW / HP

m / Ft. mm / in. kW / HP m! / s CFM

OUTDOOR COIL COMPRESSOR (Qty. Per Unit)

 AIR FILTERS

CHARGE

ROWS DEEP FINS PER 25mm (1 in.) FACE AREA m / Ft. TANDEM (10 TON NOMINAL CAPACITY) HERMETIC (5 TON NOMINAL CAPACITY) 406 x 508 x 51 (mm) QUANTITY PER UNIT 16 x 20 x 2 (in.) 406 x 635 x 51 (mm) QUANTITY PER UNIT 16 x 25 x 2 (in.) 457 x 610 x 51 (mm) QUANTITY PER UNIT 18 x 24 x 2 (in.) TOTAL FACE AREA m / Ft. SYS. #1 ( kg. / lbs.) REFRIGERANT 22 SYS. #2 (kg. / lbs.)

UNIT SIZE (MBH) 180 240 381 x 381 457 x 381 15 x 15 18 x 15 3.7 / 5 5.6 / 7.5 3 3 13.5 13.5 1.45 / 15.5 1.92 / 20.5 762 / 30 (ea.) 762 / 30 (ea.) 0.7 / 1 (ea.) 0.7 / 1 (ea.) 2.83 (ea.) 3.78 (ea.) 6000 (ea.) 8000 (ea.) 2 2 13 20 3.35 / 36.0 4.02 / 43.3 1* 2 1 5 1.40 / 15.0 7.94 / 17.5 3.86 / 8.5 4 4 1.87 / 20.0 8.16 / 18.0 8.16 / 18.0

WEIGHTS (kg. / lbs.) Cool Only Units 180 866 / 1910 240 957 / 2110 BASIC UNIT Gas Heat Units 180 975 / 2150 240 1066 / 2350 OPTIONS / ACCESSORIES Economizer 73 / 160 Motorized Damper 68 / 150 18 kW 11 / 25 36 kW 14 / 30 Electric Heaters 54 kW 16 / 35 72 kW 18 / 40 180 79 / 175 Roof Curb 240 84 / 185 Barometric Damper 20 / 45 180 91 / 200 Wood Skid* 240 100 / 220 *Allows handling of unit using 2300mm
(90") long forks.

Air 4 Filter Option is available. DM180 would use (5) 18x24x4. DM240 would use (4) 16x29x4 and (4) 16x25x4.

Unitary Products Group

19

036-21483-003-A-0104

UNIT DIMENSIONS - DM 180 & 240 UNITS

1235 (48-5/8") (180) 1337 (52-5/8") (240)

3181 (125-1/4") (180) 3461 (136-1/4") (240)

616 (24-1/4") (180) 895 (35-1/4") (240)

RETURN AIR
All dimensions are in millimeters and inches, unless otherwise specified. They are subject to change without notice. Certified dimensions will be provided upon request.

SUPPLY AIR OUTDOOR AIR (Discharge) OUTDOOR AIR (Economizer) UTILITIES ENTRY DATA
HOLE A B OPENING DIAMETER* (mm / in.) 28.6 / 1 & KO 19.1 / ! " NPS (Fem.) 92.1 / 3# & KO 76.2 / 3 NPS (Fem.) USED FOR Control Wiring Power Wiring Front Bottom Front Bottom

CLEARANCES (mm / in.)


Front Back Left Side (Filter Access) Right Side (Outdoor Coil) Below Unit Above Unit* 914 / 36 610 / 24 (Less Economizer) 1245 / 49 (With Economizer) 610 / 24 (Less Economizer) 1372 / 54 (With Economizer) 914 / 36 20 / 0 1829 / 72 With 914 / 36 Maximum Horizontal Overhang (For Outdoor Air Discharge)

NOTE: Unit and ductwork are approved for zero clearance to combustible materials when equipped with electric heat.

*KO denotes Knockout facility. *Units must be installed oudoors. Overhanging structures or shrubs should not
obstruct outdoor air discharge outlet.

20

Unitary Products Group

036-21483-003-A-0104

UNIT DIMENSIONS - GAS HEAT 180 & 240 UNITS

1235 (48-5/8") (180) 1337 (52-5/8") (240)

3181 (125-1/4") (180) 3461 (136-1/4") (240)

616 (24-1/4") (180) 895 (35-1/4") (240)

RETURN AIR SUPPLY AIR OUTDOOR AIR (Discharge) OUTDOOR AIR


(Economizer)

CLEARANCES (mm / in. )


914 / 36 610 / 24 (Less Economizer) Back 1245 / 49 (With Economizer) 610 / 24 (Less Economizer) Left Side (Filter Access) 1372 / 54 (With Economizer) Right Side (Outdoor Coil) 914 / 36 Below Unit2 0/0 1829 / 72 with 914 / 36 maximum Horizontal Overhang Above Unit3 (For Outdoor Air Discharge)


Front1

All dimensions are in millimeters and inches, unless otherwise specified. They are subject to change without notice. Certified dimensions will be provided upon request.

UTILITIES ENTRY DATA


OPENING DIAMETER* (in. / mm) 1-1/8 / 29 KO 3/4 NPS / 19 (Fem.) 3-5/8 / 92 KO 3 NPS / 76 (Fem.) 2-3/8 / 60 KO 1-11/16 / 43 Hole

Locate unit so that the vent air outlet hoods are at least: 0.9 meter (3 ft) above any forced air inlet located within 3.0m (10 ft) horizontal Front A Control Wiring (excluding those integral to the unit). Bottom 1.2 meters (4 ft) below, 1.2m (4 ft.) horizontal from, or 0.31m(1 ft) above any door Front or gravity air inlet into the building. B Power Wiring Bottom 1.2 meters (4 ft) from electric meters, gas meters, regulators and relief equipment. Units may be installed on combustible surfaces capable of continuous exposure to C Gas Piping (Front) temperatures of 92C (197F), and intermittent exposure to temperatures of 124C (255F). D Gas Piping (Bottom)** ! Units must be installed outdoors. Overhanging structures or shrubs should not *KO denotes Knockout facility. obstruct the outdoor air discharge outlet. **Opening in the bottom of the unit can be located by the slice in the NOTE: A 25mm (1 in.) clearance must be provided between any combustible material and insulation. the supply air ductwork for a distance of 0.9m (3 ft) from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate.

HOLE

USED FOR

Unitary Products Group

21

036-21483-003-A-0104

UNIT DIMENSIONS - DM180 & 240 UNITS (Cont'd.)

DUCT COVERS - Units are shipped with the bottom duct openings covered. An accessory flange kit is available for connecting side ducts. For downflow duct applications: 1. Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers. 2. Remove and discard the bottom duct covers. 3. Replace the side supply and return air compartment panels. For sideflow duct applications; 1. Replace the side panels on the supply and return air compartments with the accessory flange kit panels. 2. Connect ductwork to the duct flanges on the rear of the unit.

DETAIL X ACCESSORY SIDE SUPPLY AND RETURN AIR DUCT OPENINGS

397 15# &

610 (24") (180) 889 (35") (240)

DETAIL Y UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS

OUTDOOR COIL END OF UNIT

2337 (92")

1524 (60") 1143 (45") 3181 (125-1/4") (180) 3461 (136-1/4") (240)

CENTER OF GRAVITY

22

Unitary Products Group

036-21483-003-A-0104

ROOF CURB DIMENSIONS - DM180 & 240 UNITS

362 14-1/4") (180) 641 (25-1/4") (240 2927 (115-1/4") (180) 3207 (126-1/4") (240)

* Supply and Return Air (including duct suppport rails) as shown, are typical for downflow duct applications. For location of sideflow duct applications (on back of unit), refer to Unit Dimension details.

ROOF CURB BENEFITS

UNIT AND CURB APPLICATION

2927 (115-1/4") (180) 3207 (126-1/4") (240)

TYPICAL APPLICATIONS

Unitary Products Group

23

TYPICAL APPLICATIONS - Cont'd.

ROOF-TOP INSTALLATION (GAS/ELECTRIC UNIT SHOWN)

5005 York Drive, Norman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A Copyright by York International Corporation 2004. All Rights Reserved.

036-21483-003-A-0104 Supersedes: 036-21483-002-A-1102