BSS Troubleshooting guide

Draft Version (BSC / RNC / Transmission / BTS)

Updated by

Amit Jindal
P U B Sharma C Jaya/Uday Nayak

Tellabs details added


Additional point of RNC and BSC added

Date Revised Revision No. 11/Feb/2013 1.0 12/Feb/2013 1.1 12/Feb/2013 1.2

Comments

BSS TROUBLESHOOTING GUIDE


1 BSC

2 RNC

3 TRANSMISSION

4 BTS

BSS TROUBLESHOOTING GUIDE

OSS connectivity down - both x.25 down One X.25 down NSEI Down BVCI Down Zero Voice calls on particular Cell Unit re-start SIGNALLING LINK OVERLOAD SIGNALLING LINK DOWN SIGNALLING LINK ACTIVATION OR RESTORATION FAILURE SIGNALLING LINK SET DOWN GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON ABIS INTERFACE WDU FAULTY STMU FAULTY MCMU RESTART BCSU RESTART BCSU SWITCHOVER

Iu-CS link down Both Iu-PS links down One Iu-PS link down BASE STATION FAULTY BASE STATION OPERATION DEGRADED BASE STATION NOTIFICATION CELL FAULTY CELL OPERATION DEGRADED CELL NOTIFICATION BASE STATION LICENCE NOTIFICATION BASE STATION TRANSMISSION ALARM BEATING WCDMA BTS ALARM FAILURE IN WCDMA WBTS O&M CONNECTION RNW O&M SCENARIO FAILURE WCDMA CELL OUT OF USE HSDPA CONFIGURATION FAILED WCDMA BTS DEDICATED MEASUREMENT FAILURE HSUPA FAILURE IN WCEL WCDMA BASE STATION OUT OF USE

BFD Down in AXC (Tellabs) 3G Sites down 2G or 3G sites down (Mw ring collapsed) 2G/3G multiple sites down

SYNCHRONISATION IS MISSING Some Subscribers not able to latch on TATA network from specific handsets Rx levels differ too much between main and diversity antennas, RSSI detected Rx signal difference exceeding EXxx TRX module cooling fan s report no rotation,ESMA System module cooling fan s report no rotation ERxx DDU module has detected VSWR above minor limit at anten

S. No.

Problem

Alarm No. at BSC

OSS connectivity down both x.25 down

2175

One X.25 down

2175

NSEI Down

3315

BVCI Down

Zero Voice calls on particular Cell

7738

Zero Voice calls on particular Cell

7738

SIGNALLING LINK OVERLOAD

26

SIGNALLING LINK DOWN

1072

SIGNALLING LINK ACTIVATION OR RESTORATION FAILURE

2072

10

SIGNALLING LINK SET DOWN GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE

2070

11

3415

12

BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON ABIS INTERFACE

2993

13

BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON A INTERFACE

2992

13

DISK FAILURE

2860

14

WDU FAULTY

2861, 2692

15

STMU FAULTY

2794

16

MCMU RESTART

2692 0690,1001

17

BCSU RESTART

2692 0690 1001

18

BCSU SWITCHOVER

2692 0690 1001

19

Loss of Synchronization in BSC

2,641

20

OPERATION MODE CHANGED TO PLESIOCHRONOUS

2631

21

BSSGP VIRTUAL CONNECTION BLOCK PROCEDURE FAILED

3030

22

NETWORK SERVICE VIRTUAL CONNECTION UNAVAILABLE

3020

23

SEND BUFFER OVERFLOW IN SIGNALLING TERMINAL BSC Internal & External alarms are not reporting

2133

24

2760 BSC External alarms are not reporting

25

Alarm Description / Comments

Catergory

OSI CLNS LINKAGE NOT AVAILABLE

OSI CLNS LINKAGE NOT AVAILABLE

NonService affecting

ALL NETWORK SERVICE ENTITIES UNAVAILABLE

BTS WITH NO TRANSACTIONS

Service affecting

Service affecting

non-Service affecting

Service affecting

BTS WITH NO TRANSACTIONS

SIGNALLING LINK LOAD OVER THRESHOLD

SIGNALLING LINK OUT OF SERVICE

FAILURE IN SIGNALLING LINK ACTIVATION OR RESTORATION

LINK SET UNAVAILABLE

Service affecting NonService affecting

GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE

BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON ABIS INTERFACE

BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON A INTERFACE

Service affecting

DISK FAILURE

NO ACCESS TO DISK ,INCORRECT WORKING STATE

HW BLOCK FAILURE IN PLUG-IN UNIT, HOT LINK FAILURE ALARMS.

INCORRECT WORKING STATE working State Changed , Unit restarted

Service Threatening

Service Threatening

non-Service affecting

INCORRECT WORKING STATE working State Changed , Unit restarted

INCORRECT WORKING STATE working State Changed Unit Restarted

Failure in Synchronization Signal

The operation mode of the unit has been changed to plesiochronous due to a failure in all the external synchronization signals. Slips occur generally in the plesiochronous operation mode. The number of slips depends on the Service correctness of the control word value which is in the synchronization Threatenin unit. The situation is serious if the control word of the synchronization g unit has drifted too far from its correct value.

Service Threatening

Service Threatening

Service affecting

The system has unsuccessfully tried to block a BSSGP virtual connection as many times as defined with the BVC-BLOCK-RETRIES parameter. An acknowledgement has not been received from the SGSN. In spite of the failure the virtual connection has been marked as blocked in the BSC.

Service Threatenin g

A Network Service Virtual Connection/Link is unavailable. It cannot be used for General Packet Radio Service, that is, the data transfer capacity has decreased.

Service Threatenin g

Service This alarm reports is AS7_c of BCSU,this will cause LAPd fluctutation & Threatenin TRX fluctitation g Service Threatenin g Service Threatenin g

Hwat failure

BSC External alarms are not reporting

Affect / Steps to be follow for troubleshoot

1. Check the signalling links states at MSS end 2. If signalling links / link set down means BSC down(Alarm-Link Set Unavailable) 3. Send local engineer at BSC site 4. Check BSC end Mux status & alarm. 1st: Mux unmanaged - check alarm at connected Mux, Power issue at BSC site. Check the end-end E1 connectivity and reoute the E1 on alternate path if there is a break in main path.2. Mux managed check alarm at Mux & verify the power status for BSC. 5. Login BSC via VDU / LANU. Check the alarms & current computer unit status, if login is possible.In case login is not possible ,get login through OMU CPU and check the status of OMU and other computer units.If we will not get the login through OMU also ,raise the emergency and follow steps as per with care team recommandation.

1. Check the signalling links states at MSS end 2. If Signalling links found ok, Check the voice & data traffic at MSS & PACO end (normal or any degradation) 3. Check the Transmission path - Is there any alarm in X.25 E1 path / path broken, then re-route path & check X.25 links status. 5. If media ok, Send local engineer at BSC site 6. Locally login the BSC via VDU / LANU & check the alarms. Reset the X.25 ET as well as X.25 links. 7. If BSC not login via VDU / LANU than login through CPU of OMU unit and check the status: after login ask for password then login ok, or if continuously restarting phase means OMU unit faulty. Do as per care team recommendations. 1. Check the Transmission path - Is there any alarm in X.25 E1 path / path broken. 2. Check the alarms. If PCM ok then reset the X.25 ET as well as X.25 links from BSC . Data traffic affect, down Check no. of NESI's down, if down all - Trace PCU IP from SGSN & find last hop address & check media B/W that hop to BSC If only some NSEI down (one or two) follow below steps 1. Check the PCU - BCSU combination 2. Ping SGSN (PAPU) IP from that BCSU-PCU 3. Trace PCU IP from SGSN 4. Shift the traffic (DAP) to other PCU-BCSU 5. During MW Hrs diagnose that BCSU. 1. Diagnose ok - make BCSU in WO state and observe the alarm & UP/DL tbf. 2 Diagnose not ok - change the PCU and again run Data traffic affect, down 1. GENA toggle & check status. 2. Check PCU-BCSU combination: (a) In case a particular PCU-BCSU combination: shift the traffic to other PCU & Switchover BCSU in MW and run diagnosis. (b) PCU-BCSU combination random on many BCSU-PCU combinations - Traffic prevent - unprevent from both end and PSE re-set. (c) BCSU switchover. (d) PAPU re-set / switchover . Check hardware, cabling & commissioning

Need to give sector reset as a first step. If still persists, need to verify the traffic trend of a sector from NPO team.Then need to verify at site level like physical power level of TRX and Orientation of Antenna and Check UP/DL quality, path imbalance/VSWR/RSSI. This notice appears repeatedly - consider adding more signalling links A signalling link has failed and changed state from IN SERVICE to OUT OF SERVICE, or its initial alignment attempt has failed. Check the Transmission path If there are other path available, signalling links path re-route with discussion with planning team The activation or restoration of a signalling link fails. Signalling transmission capacity decreased. Check the Transmission path If there are other path available, signalling links path re-route with discussion with planning team All signalling links in the signalling link set are unavailable. 100% traffic of that link set Check alarm: 2064 - ROUTE SET UNAVAILABLE. If this alarm present means no route is available Check for the end to end connectivity for the Aters carrying signalling (MSC,TXN and BSC), transmission alarms.If found OK then send the engineers at the BSC for further Check GPRS/EDGE load & balance the load by reallocate the DAPs Thershold value need to be change or PCU addition require if load balancing ok.

Impact: Call drop, Quality degradation, Call muting Check the Transmission Media, if not ok then clear the path issue. If Transmission Media found OK, then check the timeslot mapping between bts and bsc should be checked. if mapping is fine, timeslot bypassing should be checked for the problem BTS/TRX, and if it is coming on more than one timeslot, and everything else is fine, trx should be replaced and call test should be done on all time slots after replacement. If it is coming for only one timeslot, the time slot may be locked till the time , replacement is made. the site should also be checked for other alarms and reqd action should be taken . Impact: Call drop, Quality degradation, Call muting Need to identify the Ater No and CCSPCM's from where there alarms are getting triggered from ZAHP of BSC, should get verify the Transmission media between the BSC and MGW for the connected ATER links. It should be corrected if any CCSPCM mismatches between BSC and MGW.After correcting this need to verify the reoccurance of alarms from history and test calls to be made.

The system has detected a serious error that may have been caused by the hard disk or the SCSI controller plug-in unit breaking down.Saving data into the hard disk or reading data from the hard disk fails.Run the diagnosis on the faulty hard disk and if diagnosis fail then change the hard disk as per standard procedure for replacing the WDU Impact: No hard disk Redundancy, Measurements might be affected. 1.Check the WDU state with ZISI :; commands . Alarm history and current alarm should be checked. If it is one WDU or both WDU are in BL-SY state . 2. Perform the JOJI of harddisk ( with JOJI the HDSAM ) and DCAR card .perform the OMU restart and check .if problem reolved, perform the diagonisis of WDU and check the all database is updated or not . 3. if problem does not resolved , swap the position of WDUs in DCAR card and check if 1. Check the status of STMU with ZUSI:STMU:; commands. Check the current & History alarms & Site/aters outage if any related to faulty STMU. 2. Check the supplementary information of alarms & work as per information . 3. Clear the faulty tag with ZUST command and observe. 4. Check the alarms of ET/ transmission and set loss with ZYWI command. 5. Temperature condition need to check at BSC location. 6. Check the STMU cabling and if required replace the Hardware. 7. Check the SFU modules by swapping with spare and isolate the break if any.

1. Check the status of computer units with ZUSI:COMP:; commands. Check the current & History alarms. 2. Check the supplementary information of alarms & work as per information (switchover / diagnose). 3. check ZIGO & ZUDH. 4. Change the state of MCMU to SE-NH and perform the JOJI of all cards og MCMU and GSW .after Diagonise the unit and check. 4. if problem repeates on same MCMU ,replace the hardware with help of alarm info. 5. Perform the diagonistics of that MCMU /EMB and make it in working State. 6. If no alarm found or problem occur on different -different units with same alarm Number it may be a SW bug. Note : Kindly note before switchoff the MCMU respective MCMU and EMB should be in SE-NH state also during any hardware replacement check the Jumper setting of the card.during any hardware replacement check the Jumper setting of the card.

1. Check the status of computer units with ZUSI:COMP:; commands. Check the current & History alarms. 2. Check the supplementary information of alarms & work as per information (switchover / diagnose). 3. check ZIGO & ZUDH. 4. if problem repeates on same BCSU ,replace the hardware with help of alarm info. 5. Perform the diagonistics of the BCSU with both MCMU and make it in working State. 6. Check the BVCI state and lapd States 7. If no alarm found or problem occur on different -different units with same alarm Number it may be a SW bug. Note : During any hardware replacement check the Jumper setting of the card accordingly. 1. Check the status of computer units with ZUSI:COMP:; commands. Check the current & History alarms. 2. Check the supplementary information of alarm & work as per information (switchover / diagnose). 3. check ZIGO & ZUDH. 4. if problem repeates on same BCSU ,replace the hardware with help of alarm info. 5. Perform the diagonistics of the BCSU with both MCMU and make it in working State. 6. Check the BVCI and Lapd state. 7. If no alarm found or problem occur on different -different units with same alarm Number it may be a SW bug. Note : During any hardware replacement check the Jumper setting of the card accordingly. 1. Check the ZDRI :; command output with Current alarms. 2. Check the ET alarms on Sync ET . 3. Disconnect the all sync with ZDRC command ,setthe ossilator control word value to 32000 on both CLS and reconnect the all sync inputs with correct priority. Note : If any BSC is out of Sync ,there will be slip on all ETs of that BSC .

1. Verify the input sync quality. 2. Monitor slips on ATER links and check the transmission path for any degraded errors. 3. Switch Hardware, if problem persists replace it.

The transmission lines carrying bearer channels/IP packets are operational and that the Network Service Entity used by the cell is OK 1. Swap BCSU of that particular cells having this alarm. 2. Give GENA reset to the cells.

Check for the transmission link errors and rectify them. The configuration at both ends should be same, If problem persists than verify the hardware associated with link and reset/change the hardware.

1:Check the alarm in which computer uint alarm is reported. AS7_C card in MW & Diagnosis of the unit. AS7_C is diagnosis is getting failed

2:Jo/Ji of 3:Replace

1:Need to give one OMU restart in MW,If still alarm persist need to replace HWAT card

1:Check the Extarnal alarmscable & connector. Check the loop test from DDF. 3: Check the continuity of cable fromend to end. if any shot with grounding

2: 4:Check

S. No.

Node

Problem

Alarm No. Alarm Description / at RNC Comments

RNC

Iu-CS link down

2070

LINK SET UNAVAILABLE

RNC

Both Iu-PS links down

2070

LINK SET UNAVAILABLE

RNC

One Iu-PS link down

2070

LINK SET UNAVAILABLE

BASE STATION FAULTY 4 Nod B

7650

No connection to Flexi transport submodule BTS reference clock missing BTS RNC/I-HSPA interface signalling link failure System module failure BTS requires restart because license status has changed BTS time not corrected

Nod B BASE STATION OPERATION DEGRADED

7651

Nod B BASE STATION NOTIFICATION

7652

Nod B BASE STATION NOTIFICATION

7652

Difference between BTS master clock and reference frequency Fan failure Heating element not working Temperature alarm Failure in optical RP3 interface Incompatible SW version detected RF module failure VSWR alarm

Node B CELL FAULTY

7653

RF module failure

Node B CELL OPERATION DEGRADED

7654 Rx signal level failure

Node B

CELL NOTIFICATION

7655

Radio resources switched off HW capacity too low for feature 308, Licence Based BTS channel c Licence missing 00000001125, Flexi WCDMA BTS 60W Power License

10

Node B

BASE STATION LICENCE NOTIFICATION

7661

Licence missing 0000000306, HSDPA 16QAM SW Licence Support Licence missing 0000000307, HSDPA Proportional Fair Resource Pac Licence missing 0000000649, Shared HSDPA Scheduler for Baseband Verification of target ID failed 3 times. License missing for feature Additional 2 E1, T1, JT1 interface o License missing for feature UBR+. (blank) (blank) AAL2 path unblock not accomplished BCCH information updating has failed

11

Node B

BASE STATION TRANSMISSION ALARM

7665

12 13

Node B BEATING WCDMA BTS ALARM Node B FAILURE IN WCDMA WBTS O&M CONNECTION

7740 7750

14

Node B RNW O&M SCENARIO FAILURE

7761 Common channel deletion has failed NBAP interface type unknown failure Block resource request, normal priority Common measurement failure scenario NBAP link failure

15

Node B WCDMA CELL OUT OF USE

7771

15

Node B WCDMA CELL OUT OF USE

7771

Resource status indication, cell disabled WCEL state not WO WCEL state not WO after setup RNC internal error

16

Node B HSDPA CONFIGURATION FAILED

7772 WBTS rejects the configuration

WCDMA BTS DEDICATED MEASUREMENT FAILURE 17 Node B

7778

18

Node B HS(U/D)PA FAILURE IN WCEL

7780

19

Node B

WCDMA BASE STATION OUT OF USE

7786 3159

(blank)

20

RNC

SCTP Association lost

FDU Faulty 21 RNC

OSS Link Down

22

RNC

23 24

RNC RNC

Redundancy issue at SET Multiple cells down in same RNC at same time

Traffic dip in RNC

25

RNC

26

Node B Interface down alarms

ROUTE SET UNAVAILABLE

27

RNC
VP/VC LEVEL AIS RECEIVED

3974

28

RNC

Cateagory

Impact

SA

RNC Total Outage

SA

RNC data traffic outage

NSA

No Data traffic outage

SA SD

Transmission to NodeB will be affected Service will be affected based on the degradtion threshold level NBAP/AAL2 signalling link failure NodeB Capacity may be reduced/NodeB totally may not be opreational Mentioned licence feature will not work

SA

SA

SA

NSA

BTS time will not be correct

NSA

BTS frequecy deviates from IuB referecne

NSA

Temparature will be increased Heating from the heating element is not available. The module temperature may not reach the working level or may reach it very slowly Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational Sectors will be affected depends on severity Depending on severity BTS Capacity may be reduced/BTS totally may not be opreational

SA

SA

SA

SA

Sectors Operation will be degraded

NSA

Sectors Operation will be degraded

SA

Cell will be down

NSA

The licenses are granted but cannot be used. Some of the licensed features are not available.

SA

Sector down

SA

SDPA Traffic will affect

NSA

Degradation

NSA

Degradation

SA

Degradation of system module

Service Degraded SA Cell Down NSA NSA Repeatation of any alarm causes BTS Cannot be logined remotly & Measurements will not be updated Cell Down

Cell Down SA Cell Down

Cell Down

Sector down

Sector down SA Sector down

SA Sector down Sector down When Site Down Or Sector Down Service Degraded SD Service Degraded

SA

DCN state - Disable Or Cell Faulty

A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty SA A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty SA SA Traffic will be affected WBTS will be down

UMS backup cannot be taken

NSA

Remote login of RNC is not possible

During main SET breakdown, outage will report 3G voice and data outage

Partial outage

Alloted Bandwidth for Site decreases

RNC Outage

Site outage

Affect / Steps to be follow for troubleshoot Possible Causes Affects: Communication with MSS down: Total outage 1. Check the unit status for any failure and check the current and history alarms 2. Ping & trace MSS control plane and user plane IP 3. Check Association set and association links status and end IP 4. Check connectivity B/W end trace IP to MSS. Affects: Communication with Both SGSN down: Total data Traffic outage 1. Check the unit status for any failure and check the current and history alarms 2. Ping & trace SGSN control plane and user plane IP 3. Check Association set and association links status and end IP 4. Check connectivity B/W end trace IP to SGSN. Affects: Communication with one SGSN down: data working fine with connected SGSN, no outage happened in 1. Check the unit status for any failure and check the current and history alarms 2. Ping & trace SGSN control plane and user plane IP 3. Check Association set and association links status and end IP 4. Check connectivity B/W end trace IP to SGSN. Malfunction of Transport Module in System Module Site Clock E1 having errors / AIS

Transmission break or fluctuations-Take ping from working OMU to TRS IP

Abnormal functioning of FSM

After licence installation BTS not given restart

NTP Server IP mismatch

DAC Valure variations

H/W Faulty-Dust on Fan

The heater control connection of the FSM is faulty, there is no heater or the heater is faulty. The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is outside the specified limits. Abnormal/ failure in optical cable between FSM & FRGP SW Mismatch of BTS Abnormal functioning of FRGP High VSWR

Abnormal functioning of FRGP

The RX signal level is less than -112dBm or the difference between the maximum and minimum power levels of all RX antennas in the same cell and sector is more than the limit (4 dB). The jumper cable is faulty, water entry, RF module antenna port faulty

As per configuration H/W mismatch/unavailability

The HW capacity is too low to support all licenses of an optional feature. Problem reports when HW is loaded with more than specified number of CEs

During NodeB commissioning seleted 60W power for sector.

HSDPA License Missing Or Cell Down

License missing

License missing

Hanged/config issue/comm issue

This basic license missing

HSDPA License Missing Repeatation of any alarm causes DCN Configuration mismimatch in NodeB/RNC/tellabs-All E1s are down/Media is not ready CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs

CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs

CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs

CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs

Cell Down

Cell Down Cell Down

Cell Down Cell Down Cell Down Cell Down / Interface Down Or H/W configuration In Node-B

Cell Down / Interface Down Or H/W configuration In Node-B

DCN connected E1 Interface needs to be cross check. The alarm reports only after OP3 interface failure

Cell Down

Cell Down Cell Down CNBAP/BRM Break

IuCS/IuPS CP, IuR

OMU switchover, corrupted disk

TXMN path, physical connectivity, ESA port, ESA

MSP Configuration at RNC and tellabs ICSU

TXMN backbone

TXMN Path, physical connectivity, Port faulty in MUX, IDU, TM

TXMN, Physical connectivity, Ports faulty

TXMN, Physical connectivity, Ports faulty

Solution 1: After checking points 1,2 &3 in Column G, Check the ping response and traceroute. 2: Based on traceroute, note the problematic hop, and start working on that hop and beyond. 3: The possible cause would be port fault at any router, port configuration etc. 4: If problem is observed in the first hop, then need to check for HW/ Physical connectivity 1: After checking points 1,2 &3 in Column G, Check the ping response and traceroute. 2: Based on traceroute, note the problematic hop, and start working on that hop and beyond. 3: The possible cause would be port fault at any router, port configuration etc. 4: If problem is observed in the first hop, then need to check for HW/ Physical connectivity 1: After checking points 1,2 &3 in Column G, Check the ping response and traceroute. 2: Based on traceroute, note the problematic hop, and start working on that hop and beyond. 3: The possible cause would be port fault at any router, port configuration etc. 4: If problem is observed in the first hop, then need to Reset System Module/Replace Transport Module in System Module Clock E1 Interface needs to be check & Check the SYNC of TXN side Check transmission configurations and paths

Reset FSM/Replace FSM

Restart BTS.

Check NTP server IP it should be same as RNC OMS IP

Set DAC value to standard value

Check working status of Fans or replcae FAN units in FSM Check whether the heating element exists at all./ Check the heater control connection and that the heater is working./ Replace the alarming component. Check the FAN units in FSM/FRGP Check the Optical cable connecton between FSM & FRGP/Reset FSM/Replace cable. Recomission BTS with Correct SW version Reset FRGP/FSM/Check interface cables/Replace FRGP Check the VSWR, should be less than 1.3

Reset FRGP/FSM/Check interface cables/Replace FRGP

1. Locate the problem with supplementary information fields of the alarm. 2. Verify the BTS by checking the commissioning, cabling and correct installation of the units/modules at the WCEL. 3: Check for RX level value, at ports in questions, and resolve the fault, either by reconnectorisation, changing jumper cables, RF module.Check the VSWR & Antenna cables Check the cell configration & H/W availbilty at site

Call to GNSC CM Delete the licenses or insert new hardware.

Login to nodeB and change parameters of sector power to 20W

Call to GNSC CM get it clear

License missing

License missing

Hanged/config issue/comm issue

GNSC has to load this basic license from Netact

GNSC has to load this basic license from Netact Cancels once causing Alarm is cleared To be checked DCN Configrations at RNC/NodeB/Tellabs To be checked CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs To be checked CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs To be checked CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs To be checked CoCo/ATM Configuration Mismatches between NodeB/RNC/Tellabs Need to check WCELL/WBTS alarm

Need to check WCELL/WBTS alarm Need to check WCELL/WBTS alarm

Need to check WCELL/WBTS alarm Need to check WCELL/WBTS alarm Once Node-b is up, alarm will clear Node-B Lock & Unlock Or Restart Node-B / Cross check & Rectify Node-B H/W Configuration --All This action based on Sublimentory information of Alarm Node-B Lock & Unlock Or Restart Node-B / Cross check Node-B H/W Configuration --All This action based on supplementary Alarm Info. DCN Interface / Lock all the cells under the BCF and delete & Re-create COCO configuration and unlock all the cells / If required Site reset has to be given ( Anlaysis based on supplementary info) 1. Firstly check the working state of WCEL. 2. Resolve the other active alarms for the same WCEL or its parent WBTS object. 3. A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty A unit (or units),taking care of HSUPA traffic in the WCEL can be faulty Check the transmission path & Configuration between NodeB to RNC 1: Check destination address, SPC 2: Based on Point1 OP, further troubleshooting required similar to "2070" alarm in RNC. 1: Check whether the USB stick is present in FDU of working OMU. 2: If FDU is not coming to working state in working OMU, then JOJI of FDU need to perform. 3: Replace the USB stick with new USB(USB might be corrupted, if it is used in laptop to copy backup files. 1: Check the reachability of RNC from Router to identify problematic hop. 2: If problematic hop is found before gateway IP of RNC, need to check the TXMN path. 3: From Router, last hop reachable is next to gateway IP of RNC, then need to check cabling between RNC and its first hop. 4: From Router, last hop reachable is gateway IP of RNC, then need to check ESA port, ESA card.

1: Check for MSP configuration at Tellabs and RNC. 2: JOJI of SFP modules to be carried out. 3: Replace the SFP. 1: Check whether the cells controlled by same ICSU. 2: Swicthover ICSU with the SP unit. 1: Problem may report in Voice and Data. 2: Take ping wrt destination address for UP/CP. 3: Take traceroute OP wrt destination address for UP/CP. 4: The problematic hop can be identified by the hop where more delay is observed in traceroute. 5: If no such hop found, need to analyse fishing logs and IMSI based trace from RNC. 1: Check the E1 status from NMS, KLM mapping, option for re-routing etc 2: If LOS observed at site end in NMS, the cable may be faulty, port faulty in MUX/TM. 3: Check for BW availability in TXMN Backbone. 1. Check the supplementary information to which signaling traffic to the signaling point indicated is totally blocked. 2.If the signaling link sets to the STP concerned are available, then there may be a fault in the network configuration. 1. The error can be in the physical link, hence check for particular physical path. 2. Verify the configuration for that link.

S. No.

Problem

Alarm No. at BSC

Alarm Description / Comments

Catergory

BFD Down in AXC (Tellabs)

7665

BFD down

Service Degradation

3G Sites down

Base Station out use

Service affecting

2G or 3G sites down (Mw ring collapsed)

Fault rate monitoring & PCM failures

Service affecting

2G/3G multiple sites down

Fault rate monitoring & PCM failures

Service affecting

M/W Link Problem

No Alarm observed in the link, except RSL dip at one end.

At one end, RSL of the link is OK, on other end it dips to -90dBm. No typical alarm observed in the link.

Service Threatning

Affect / Steps to be follow for troubleshoot BFD down or fluctutating in AXC & data traffic shifted to ATM, Cause HSPA fallback enabled. Checked txn media as well as ISA card or reset Mux ISA card to restore BFD. Need to check utilization of GE ports, If broadcast packets incresing then need to check the txn- media & ISA card. Deimplement trails for culprits ISA & raplace ISA ASAP. Downs sites need to be check belongs particular AXC card or Mux particular STM-1 port. Need to check alarms on port, If any alarm appears then switch to redundant port to restore sites If the CPU utilization for both Main & Spare IFMcard are hign then remove one by one & inserted Main card to reduce CPU utilization. Atlast switched CDC card from main to redundant card.

Need to check alrams on ALU mux port during ring collapsed at both end. Need to ping connecting IDU from GNOC to check alarms & w.r.t appeared alarms we identify either power issue or hardware fault Enginners need to send at site with hardware for further trouble shooting. Sites need to be indentified on particular MUX Core mux malfunctioning at BSC/RNC location 2G & 3G site database shared with all CTLs Impact: Microwave Link gets down Reason of the problem: Normally in this type of scenario, ODU of the link (at the end where RSL is OK) is misbehaving. Its transmitor gets off, stops radiating. But, it receives the signal properly.

Troubleshooting: ODU to be replaced

S. No. Problem

BTS Type

1 SYNCHRONISATION IS MISSING All External Q1 device fail to respond

Flexi/MR

Alarm Alarm Description / Comments No. at BSC 7787 DFCA not working in that particular Site,One more Observation:Site will continously restart when DFCA is enabled in the site

2 a)Some Subscribers were not able Flexi Edge to latch on TATA network from BTS specific handsets.While Same Handsets were running fine with IDEA or any other operator from a perticular site (N_UW_NRA_001,Muzzafarnagar)

Observation:At Problematic location/Premises(N_UW_NRA_001,Muzzafa rnagar) there are two NSN equipments serving for IDEA/TATA.No alarm was found on problematic site.

3 Rx levels differ too much between Flexi main and diversity antennas, RSSI detected Rx signal difference exceeding threshold

7607 Rx levels differ too much between main and diversity antennas, RSSI Value is high than 10.

4 EXxx TRX module cooling fan s report no rotation,ESMA System module cooling fan s report no rotation

Flexi

7607 TRX cooling fan not rotate ESMA cooling Fan not rotate

5 a)ERxx DDU module has detected VSWR above minor limit at anten

Flexi/MR

7607 VSWR limit is high than 1.5 for Minor alarm and >2.7 for major alarm

BTS Faulty

Flexi / Ultra

7603

This alarm blocks the alarming sector.

Rx LEVEL DIFFER BETWEEN MAIN AND DIVERSITY ANTENNA

Flexi / Ultra

7604

There is a difference between RX level of main and diversity antenna of BTS.

CH CONGESTION IN CELL ABOVE DEFINED THRESHOLD

Flexi / Ultra

7746

The percentage of rejected channel seizure requests due to congestion as opposed to all channel seizure requests in the base station is above the operator-defined alarm threshold.This alarm describes the congestion situation of the whole cell although it is only given to the BCCH BTS. The alarm is used to supervise the traffic capacity of the base station.

NO E GPRS TRANSACTION IN BTS

Flexi / Ultra

7789

No successful (E)GPRS transactions have occurred within the supervision period

10

There is a difference in the reference frequency of PCM and base station.

Flexi / Ultra

7601

DIFFERENCE BETWEEN PCM AND BASE STATION FREQUENCY REFERENCE

11

This alarm is generated, If there is a fault in input/output power supply or temperature of TRX is high/low or cooling fan faulty

Flexi / Ultra

7602

TEMPERATURE, POWER INPUT/OUTPUT AND COOLING FAN FAULTY

12

The Abis frequency is too high or too low, or it fluctuates so much Flexi / Ultra that the master clock tune is unreliable and tends to oscillate too much. The system has blocked the radio time slot because the call control has failed a number of times in the activation of a radio channel.

7616

OSCILLATOR ADJUSTING TEMPORARILY INTERRUPTED

13

Flexi / Ultra

7725

TRAFFIC CHANNEL ACTIVATION FAILURE

Catergory

Affect / Steps to be follow for troubleshoot

Service affecting 1.First step to check the site is down or not (ZEOL) 2.if site is working with DFCA unsync and LMU is in stand by mode (ZEFL) than visit the site 3.Check the parameters such as LMU area parameter,DFCA disabled or enabled 4.Check ESLA cable connectivity between ESMA to LMU ,if found any Service affecting Activities steps as follow:1.Firstly we Check Infra condition of the site 2.Check the BTS configuration of the site ,properly check weather there is any alarm in site,But no service affecting/Service degrading alarm found 3.After that we check DAC value,RSSI comparision value and VSWR value with Site master but problem not resolved. 4.Change the PLMN allowed from 1 upto 7. 5.Replaced the ESMA card. 6.Shift BCCH to another TRX and check 7.Shift BCCH to another TRX and check. 8.Swapping of TRX's from other perfet site to problamatic site and check. 9.Site deletion and further recreation done still no improvement found 10.Rehome the site BCF-22/ Muzaffarnagar BSC to Meerut -1 BSC with Service 1.Check the RSSI measurements with BTS Manager. Degrading 2.Check the BTS RF cables and connections.Check the antenna and RX cabling. 3.If the antenna and RX cabling are faulty, correct the problem and run TRX test to cancel the alarm. 4.Check and measure VSWR of the antenna lines. Service 1.90% there is a chance of Over heating or Room tempurature high inside Degrading shelter 2.if there in an issue of tempurature resolve the issue along with IP 3.Check that the fan unit cable is correctly connect to DTRX/ESMA 4.Check that there are no obstacles preventing the fan(s) from rotating 5.Clean the fan unit of dust and/or dirt 6.if problem is still presist then Replace the fan unit service affecting 1.Measure VSWR value with Site Master ,If value is found high then second step is to see the fault via Distance to fault location . 2.According to distance found, replace connector,Jumper ,Anteena or damaged feeder cable 3.With external test equipment check VSWR of the antenna line. Repeat step 1 if the measurement is again high
service affecting 1. Analyse and rectify other TRX related alarms in this particular BTS. 2. Verify EDGE settings as per configuration.

service affecting

1. Check the difference in RSSI measurements by BTS Manager. 2. Check and measure the antenna lines with >2 db difference. 3. Check the VSWR of particular BTS RF cables and connections. 4. Replace the combiner unit. Check that the RXDL parameter at the BSC is set to a reasonable value, taking into account the site conditions in order to prevent unnecessary alarms. 5. Replace the TSxx unit.

service affecting

1. Check the object of congestion in supplementary info. 2. Verify parameter settings and change the default values. 3. Permanent solution is Increase the network capacity if necessary.

service affecting

The BSC's ability to transfer GPRS/EDGE traffic in the BTS has been totally prevented. 1. Swap BCSU of that particular cells having this alarm. 2. Reducing the default GPRS/EDGE / extended cell area GPRS/EDGE channels connected to PCU 3. Reducing the amount of dynamic Abis pool (DAP) timeslots connected to the PCU 4. Moving one cell/segment from the failed PCU to another PCU Difference in the PCM and BTS synchronisation. 1. Analyse the bunch of alarms coming in particular Tx node. 2. Check the synchronisation settings of the transmission interface. 3. If the settings are OK, check the transmission chain.

service affecting

service affecting

1. Check the conditions related to alarm occurs and resolve the infra related problems. 2. Replace the hardware.

service affecting

Check for the transmission link errors and rectify them. If problem persists than change the hardware.

service affecting

1. Analyse and monitor affected RTSL by checking supplementary info. Reset if frequency is greater. 2. If proplem persist, block that RTSL and shift the channel type as per needs. (e.g. SDCCH) 3. The no. of block RTSL is >2, than replace TRX.

D:\userdata\alekar\ Desktop\BSS Fault

BCF Alarm Guide

S. No. Problem

Alarm No. at Tellabs

Loss of timing input

Ospf neighbor mtu mismatch

Conflicting module

If conn rx power too high/Low

Incompatible hw version

Incompatible sw version

Inventory installation error

No application sw

Cooling fans not running

10

Node clock missing

11

Loss of IMA links

12

RX circuit down

13

IMA link RX misconnect

14

Loss of frame

15

Loss of IMA link delay synchronisation

16

Unequipped

Alarm Description / Comments The clock selection process is not receiving any proper clock signal (due to empty fallback list or all clocks in fallback list are failed). Therefore holdover clock is used. Neighbor MTU size is different than in this interface. Ospf not started. The activated module is different from the one physically present

Catergory

SA

SA

SA

SFP Received Power exceeds high alarm level set in SFP.

SA

The unit has incompatible HW version with expected one This unit has incompatible SW version with referred unit. The expected configuration is not specified. At minimum it must contain at least one control unit There is no downloaded software in the unit, or all software files are deactivated. All the fans or more than one fan in the same fan group are rotating more slowly than requested, are not rotating at all, or the RPM information is not available for the fans.The reason for this fault can be too low supply voltage or a broken fan.Perform the steps below in the listed order until the alarm disappears.

SA

SA

SA

SA

SA

Synchronization module is not feeding clock to this unit

SA

An IMA-related remote defect has been detected. A Loss of IMA link (LIF) or Link out of delay synchronisation (LODS) alarm is active at the far end of the IMA link. Circuit is down in receive direction. The reason may be that the LDP signalling is not successfully executed. IMA link Rx mis-connect fault. The alarm indicates that Rx link is detected to be mis-connected. This is reported when the IMA unit has determined that the Rx link is not connected to the same NE IMA unit as the other Rx links in the group.

SA

SA

SA

Loss of frame alignment

SA

An IMA-related remote defect has been detected. A Loss of IMA link (LIF) or Link out of delay synchronisation (LODS) alarm is active at the far end of the IMA link. High Order Path Unequipped. The path signal label byte (C2) and the path trace byte (J1),and BIP-8 byte (B3) in the SDH path overhead (POH) all have the value zero. The path is unusable for traffic transport.Probable cause: the unequipped VC-3/VC4 comes from a VC-level cross-connection node and the VC-3/VC-4 is not connected anywhere in that node.

SA

SA

Affect / Steps to be follow for troubleshoot Sync source to be checked. If the proper sync source is defined, then we need to check the priority setting at the source. OSPF needs to be restarted. Topology may have to be checked. Module needs to be activated and configuredas per the planned configured physical module 1.SFPs are to be checked. 2.We may have to check for the attenuators added or not. If yes, what is the rating / value. 3. Output power at the card level is to be checked. Unit with newer HW version is required Either the unit or referred unit SW should be upgraded The inventory can be added by re-creating the inventory From the management console, new sw will have to be loaded.

1.Check the fan and cabling, 2. Replace the faulty fan module.

CDC cards are to be checked. We have to JOJI the primary CDC after making the secondary card up. Card replacement should follow, if still alarms exists.

Probable causes:disturbance on the line,physical link defect,- loss of IMA frameloss of delay synchronisation,for handling the alarms raised at the far end of the IMA link. LDP signalling is to be checked and executed.

Delete and recreate the complete link. Check the complete path as well.

This is a transmission alarm. The frame/multi frame is not received at the far end properly. Need to check the Tx path. Probable causes:disturbance on the line,physical link defect,- loss of IMA frameloss of delay synchronisation,for handling the alarms raised at the far end of the IMA link. 1. Check the configuration and ensure that the cross-connections between the nodes have been properly configured for transporting traffic. 2. Ensure that the Path Payload Label for the VC-3/VC-4 at the far end is configured to be"ATM". 3. Follow the signal in the network and check whether any other alarms concerning the fault are active.