DATA SHEET

CLIENT: JOB: AREA: TITLE:

FD-9999.93-1230-???-???-007
SHEET

OF

PROCESS DATA TANK

REVISION INDEX
REV. DESCRIPTION AND/OR AFFECTED SHEETS

REV.
DATE DESIGN EXECUTION CHECK APPROVAL
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN. THIS FORM IS PART OF PETROBRAS N-329 REV.D ANNEX A - .

DATA SHEET
AREA TITLE

FD-9999.93-1230-???-???-007
SHEET

REV.
OF

PROCESS DATA TANK


General Data
Rev.

Item N Service Roof Type Bottom Type Operating Capacity m

TQ-1230001

Quantity

Conic Conic with slope to the center Nominal Diameter mm Nominal Height mm

Fluid Properties
Product

Normal Op. Temp. Density at Normal Op. Temp. Viscosity at Normal Op. Temp. Specific Heat Vapor Pres. Abs Normal Op. Temp. Max. Op. Temp.

C kg/m cP kcal/(kg. C) kgf/cm kgf/cm C

NOTA 01 Flash Point

Operating Conditions
Temperature Storage (Min/Normal/Max.) Loading (min./Normal/Max.) C C kgf/cm m/h m/h 0 16 16 20 25 40

Gauge Pressure (Normal/Max.) Max. Product Inlet Flow Rate Outlet

Design Conditions
Standard Design Temperature Gauge Pressure Vacuum Pressure Valve Set Pressure Vacuum PSV (Gauge) C kgf/cm
mmH2O

Accessories
Floating Suction Mixer Type Quantity Type Quantity

kgf/cm
mmH2O

Foam Chamber Foam Applicator

kgf/cm Type Heating Fluid Thermal Load

Heating System

Thermal Insulation
Type Purpose Roof Material Thickness Material Thickness Material Thickness mm mm mm

kcal/h C
kgf/cm

Temp. (Inlet/Normal/Outlet) Gauge Press. (Inlet/Normal/Outlet) Heating Time Mass Flow Vapor Quality Steam Temperature Film Coeff. (Internal/External) Specific Heat 1 Fouling Factor

Shell

h kg/h % C kcal/(m.h. C) kcal/(kg. C) (m.h. C)/kcal

Bottom

Local Data
Ambient Temp. (Min/Normal/Max) Atmospheric Pressure Max. Pluviometric Precipitation Average Wind Speed Wind Direction C atm mm

THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN. THIS FORM IS PART OF PETROBRAS N-381 REV. K ANNEX A - FIGURE A.2

DOCUMENT GENERATED BY COMOS

km/h

DATA SHEET
AREA TITLE

FD-9999.93-1230-???-???-007
SHEET

REV.
OF

PROCESS DATA TANK


Service Obs.
Rev.

Item

Qty

Diam. in

Class

N01 N02

1 1

THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN. THIS FORM IS PART OF PETROBRAS N-381 REV. K ANNEX A - FIGURE A.2

DOCUMENT GENERATED BY COMOS

DATA SHEET
AREA TITLE

FD-9999.93-1230-???-???-007
SHEET

REV.
OF

PROCESS DATA TANK

Note 01

Description NOTA 1 POSICIONADA SOBRE O CAMPO DE PONTO DE FULGOR.

THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN. THIS FORM IS PART OF PETROBRAS N-381 REV.J ANNEX A - FIGURE A.1.

DOCUMENT GENERATED BY COMOS

DATA SHEET
AREA TITLE

FD-9999.93-1230-???-???-007
SHEET

REV.
OF

PROCESS DATA TANK

NOTA 1:

NOTA2:

THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN. THIS FORM IS PART OF PETROBRAS N-381 REV.J ANNEX A - FIGURE A.1.

DOCUMENT GENERATED BY COMOS

DATA SHEET
AREA TITLE

FD-9999.93-1230-???-???-007
SHEET

REV.
OF

PROCESS DATA TANK


Sketch

THE INFORMATION CONTAINED IN THIS DOCUMENT IS PETROBRAS PROPERTY AND MAY NOT BE USED FOR PURPOSES OTHER THAN THOSE SPECIFICALLY INDICATED HEREIN. THIS FORM IS PART OF PETROBRAS N-381 REV. J ANNEX A - FIGURE A.2

DOCUMENT GENERATED BY COMOS