Sie sind auf Seite 1von 3

1

Col.
Top Beam
Beams
RCC UPTO PLINTH

Grade Beam
Col.
Padestal

Brick Work:
Filler Walls
PCC in Foundation:
PCC Under Grade Beam
2

NOS.

No.

Qnty

8
8
8

2
1
2

8.1
6.9
4.9

1
1
0.6

0.3
0.3
0.3

38.88
16.56
14.11
69.55
7.06
14.40
2.11
25.34
48.91
69.09
4.78

SIDE WALLS: 4 NOS. PAIRS @44M, 55M, 85M, 97M


SIZE: 9.1(H)X6.9(W)X0.3(T)
RCC Above PLINTH

BAFFLE WALLS: 2 NOS. @ 34M, 70M


Size: 35.8m(6.9+22+6.9) Width & 9.1Height; 4.1m clearance above GL
RCC Above PLINTH
Inner Col.
Outer Col.
Top Beam
Top Band
Int. Beams

8
8
8
8

1
2
2
2

4.9
3
1.1
2.2

0.6
1
0.4
1.2

0.3
0.3
0.3
0.6

8
8

3
2

4.9
2.3

2.35
1.3

0.25
0.1

2
2
2
2
2

2
2
1
1
2

2.9
4.6
35.8
35.8
4.9

1
1
3
0.3
0.6

0.3
0.3
0.3
0.3
0.3

RCC UPTO PLINTH

Grade Beam
Col.
Padestal

2
2
2
2

2
4
4
4

4.9
3
1.1
2.2

0.6
1
0.4
1.2

0.3
0.3
0.3
0.6

Brick Work:

Filler Walls
Top wall

2
2

4
1

4.9
33.8

1.83
1.7

0.25
0.25

2.3

1.3

0.1

PCC in Foundation:
PCC Under Grade Beam

3.48
5.52
64.44
6.44
3.53
83.41
3.53
7.20
1.06
12.67
24.46
17.93
28.73
46.66
2.39

Cum

Cum
Cum
Cum

Cum

Cum
Cum
Cum
Cum

STOP BUTT:
Size : 40m width (9+22+9) & 12m height
RCC Above PLINTH
Inner Col.
Outer Col.
Top Beam
Top Band
Int. Beams

1
1
1
1
1

2
2
1
1
2

5.4
9.1
40
40
7

1
1
3
0.3
1

0.3
0.3
0.3
0.3
0.3

RCC UPTO PLINTH

Grade Beam
Col.
Padestal

1
1
1
1

2
4
4
4

9
3.1
1.5
3

0.9
1
0.4
1.2

0.3
0.3
0.4
0.8

Brick Work:

Filler Walls
Top wall

1
2

4
1

7
38

2.55
2.4

0.25
0.25

3.1

1.6

0.1

1
1
1
1
1

2
1
1
1
1

5
5
23
37
37

1
1
7.5
2
1

0.3
0.3
0.3
0.3
0.3

PCC in Foundation:
PCC Under Grade Beam

3.24
5.46
36.00
3.60
4.20
52.50
4.86
3.72
0.96
11.52
21.06
17.85
45.60
63.45
1.98

Cum

Cum
Cum
Cum
Cum

Back BOX of Stop Butt: Size 22X7.5x6m


RCC Above PLINTH
End Col.
Extra Col. Rear Side
Top Slab
Top Beam for slab
Int. Beams
RCC UPTO PLINTH

Grade Beam
End Columns
Extra Col.
Padestal

1
1
1
1
1

1
2
1
2
1

37
4
4
1.1
2.2

1
1
1
0.4
1

0.3
0.3
0.3
0.3
0.5

3.00
1.50
51.75
22.20
11.10
89.55
11.10
2.40
1.20
0.26
1.10
16.06

Cum

Cum

Brick Work:

Filler Walls
Side walls

PCC in Foundation:
PCC Under Grade Beam
BOUNDARY WALL: 3.6m Ht. around the Range of Plan Area 157mx70m
Perimetre: 454m
No. of Columns: 151+16=167; say 170 columns
RCC above Plinth:
Columns
Grade Beam
Coping
RCC Upto Plinth:

PCC

1
1

4
2

10.5
7.5

2.5
5

0.25
0.25

2.3

1.2

0.1

Column Padestal
Under Grade beams

170

1.2

0.9

0.1

55.08
40.86
23.84
119.78
55.08
7.48
74.80
137.36
18.36

Brick Wall upto Plinth


Brick Wall Above Plinth

1
1

1
1

403
403

1.35
2.3

0.25
0.25

136.01
231.73

Columns
Padestal
Padestal

1
1
1

170
1
1

2.4
454
454

0.45
0.3
0.35

0.3
0.3
0.15

1
1
1

170
170
170

2.4
0.55
1.1

0.45
0.4
0.8

0.3
0.2
0.5

26.25
18.75
45.00
0.83

Cum
Cum
Cum

Cum

Cum
Cum

Brick work:

RCC upto plinth


RCC upto plinth
Brick work
PCC

247.85
414.79
591.94
28.35

Cum
Cum

Das könnte Ihnen auch gefallen