High vibration protection on HP Feed water pumps on STG11 and STG12

Dear Sir, Bearing vibration system has been installed on ST11 and STG12 HP feed pumps and cooling tower CW pumps for the monitoring of bearings, motor and pump condition. The data logging has also been started by the shift operation staff. Operator alert has been provided in case of high and very high vibrations. The motor and pump alarm / Trip values are preliminary set as follows. Vibration Status Pump vibration high alarm (driving or non driving end) Pump vibration very high alarm (driving or non driving end) Motor vibration high alarm (driving or non driving end) Motor vibration very

Value
10 mm/s (rms) 15 mm/s (rms) 5 mm/s (rms) 7.5 mm/s (rms)

Pump Alarm Text Status


Running CAPHPDSH101 HP FWP1 SUCT FILTER DIFF PRESS - HIGH (SAME ALARM FOR OTHER PUMPS) CAPHPHHB101 HP FWP1 SUCT FILTER DIFF PRESS - V- HIGH CAPHPHHB201 HP FWP2 SUCT FILTER DIFF PRESS - V- HIGH CAPHPHHB301 HP FWP3 SUCT FILTER DIFF PRESS - V- HIGH CAPHPDSH101 HP FWP1 SUCT FILTER DIFF PRESS - HIGH (SAME COMMON ALARM FOR OTHER PUMPS) CAPHPHHB101 HP FWP1 SUCT FILTER DIFF PRESS - V- HIGH CAPHPHHB201 HP FWP2 SUCT FILTER DIFF PRESS - V- HIGH CAPHPHHB301 HP FWP3 SUCT FILTER DIFF PRESS - V- HIGH

Trip

Running

Trip

high alarm
(driving or non driving end)

The stand by pump will start on auto if available. The work for addition of protection on CW pumps is in progress and will be communicated later on. Thanks, Muhammad Jamil Instrument engineer-2