Sie sind auf Seite 1von 50

Free-Online-Exams.

com

HP
Exam HP2-T25
Servicing HP Rack-Tower Server Solutions

Total Questions: 67

Free-Online-Exams.com

- QUESTION NO : 1

Which type of memory is used on the Smart Array controller cache? A. SDRAM B. SRAM C. RDRAM D. DRAM

Answer: D Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00687518/ c00687518.pd f(page 4, write-back caching, 5thparagraph)

- QUESTION NO : 2

Which statement is correct about the HP iLO Management Engine? A. The health driver (agent management) is the only tool for SIM to collect server information from the iLO Management Engine. B. Intelligent Provisioning is one of the major features residing in the iLO Management Engine. C. The Active Health feature in the iLO Management Engine does not monitor hardware. D. It does not apply to ProLiant 100 G8 series.

Free-Online-Exams.com

Answer: B Reference:http://h18013.www1.hp.com/products/servers/management/ilo/videos. html(first paragraph on the page)

- QUESTION NO : 3

Which LED is a new feature for the 6 GB SATA disk drive in Gen8 servers? A. Configuration B. Activity C. Do Not Remove D. Unit

Answer: C Explanation:

- QUESTION NO : 4

CORRECT TEXT Match the correct UPS description with each picture. see exhibit below,,,

Free-Online-Exams.com

Free-Online-Exams.com

Answer: Figure- 1R7000 Figure- 2R8000/3 Reference:http://h30094.www3.hp.com/product/sku/3752822/mfg_partno/AF431 A&jumpid=in_r39 24_us%2Fen%2FSASS-SMB-PS%2FCustomerViewed%2FOverview%2FSelect% 2FSMBPS% 3AServer+options%3APower+options%3ARack+UPS%2FAF431A%2FAF434A Figure- 3R1500 G3 Reference:http://computers.pricegrabber.com/upss/m/888222408/ Figure-4R1000 G3 Reference:http://www.ht.com.au/part/W8111-HP-UPS-T1000-G3-UPS-1000 -VA/detail.hts

- QUESTION NO : 5

Which hardware-based system security feature can securely store information, such as passwords and encryption keys, and can be used to authenticate the platform? A. TPM B. DHCP C. RBSU D. ORCA

Answer: A Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01681891/ c01681891.pd f(page 2, Overview, second paragraph, first sentence)

Free-Online-Exams.com

- QUESTION NO : 6

What is the term that describes the full backup typically performed by a system administrator every week? A. grandfather, father, son B. fathers C. grandmothers D. sons

Answer: A Reference:http://www.amarillodatasafe.com/Backup_rotation.htm(What is GFS, first paragraph)

- QUESTION NO : 7

Which tool should you use to configure an MSA2312FC? A. Option ROM Configuration for Arrays B. Array Configuration Utility C. Array Diagnostic Utility D. Storage Management Utility E. Intelligent Provisioning

Free-Online-Exams.com

Answer: D Explanation: http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c02520791/c 02520791.pdf This guide provides information about managing an HP P2000 G3 MSA System by using its web interface, Storage Management Utility (SMU).

- QUESTION NO : 8

Which RAID level allows the data to be striped across multiple RAIDs? (Select two.) A. RAID 0 B. RAID 1 C. RAID 5 D. RAID 50 E. RAID 60

Answer: D,E Reference:http://www.iscsi-raid.com/raid50.html RAID 0, 50 and 60 are striped RAIDs RAID 50 and 60 are striped over multiple RAIDs

- QUESTION NO : 9

Free-Online-Exams.com

Which key must you press to access the Intelligence Provisioning Maintenance Menu? A. F9 B. F10 C. F11 D. F12

Answer: B Reference:http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp? objectID=c032488 78&lang=en&cc=us&taskId=101&prodSeriesId=5177957&prodTypeId=15351(boot options, 2ndbulleted point) How does it work? It comes integrated as a flash chip on the motherboard that gets loaded with software during HPs manufacturing process. When the server is booting, press F10 during POST and the server will boot into Intelligent Provisioning software.

- QUESTION NO : 10

CORRECT TEXT Match the correct description to each image. see exhibit below,,,

Free-Online-Exams.com

Answer: Figure-1iPDU intelligent extension bar(reference:http://www.cbccomputers.com/index.php/components5/power-supplies/powerextensions/hp-5xc13-intelligent-pdu.html) Figure-2power distribution rack Figure-3iPDU core(reference:http://www.spf-co.com/spf_products.htmthird last image) Figure-4Modular PDU

Free-Online-Exams.com

- QUESTION NO : 11

Which RAID level is known as Advance Data Guarding (ADG)? A. RAID 1 B. RAID 5 C. RAID 6 D. RAID 10

Answer: C Reference:https://docs.google.com/viewer? a=v&q=cache:gewekAsmMmsJ:h50146.www5.hp.com/ products/storage/whitepaper/pdfs/c00386950.pdf+&hl=en&gl=pk&pid=bl&srcid= ADGEEShLudtCfg qzoqw3YP7r256VsTGHR9HnIYgjc5chu_A4bW9mDcDVX2PhyAexZ68 YOYNuUBubseYyg02aZ1e JQr30hFKM2vgdur3yX8l8yTNp6UWljXQNnjD40PUXRQF7HeSlgSH& sig=AHIEtbTMc5Z9wJWkA8j-tA53976vKR-Zrw(page 2)

- QUESTION NO : 12

What is achieved on ProLiant Gen8 Servers by including temperature sensors on stand-up components within the server (3D Sea of Sensors)? A. Cooling fans on stand-up components only run at 50% utilization. B. It provides more precise and more efficient cooling. C. It requires half the number of fans than in previous server models. D. Dedicated cooling fans are included on all stand-up components.

Free-Online-Exams.com

Answer: B Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03227849/ c03227849.pd f(page 6, HP sea of sensors 3d) When temperatures get too high, sensors can kick on fans and make other adjustments to reduce energy usage.

- QUESTION NO : 13

Which statements are correct about SIM 7.0 Agentless Management? (Select two.) A. HP SIM communicates with the CPU and collects essential data for the OS. B. Agentless Management Service runs on the host to provide software information directly to the iLO Management Engine. C. HP SIM communicates with the iLO Management Engine to collect hardware data. D. Agentless Management is provided by the CPU.

Answer: C Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03306157/ c03306157.pd f(overview of HP agentless management, all three paragraphs) Agentless Management, allows you to monitor core hardware and related alerts without installation of agents or providers on the host OS. With the Agentless Management solution, the management software (SNMP) operates within the iLO firmware instead of the host OS and frees memory and processor resources on the host OS for use by server applications.

Free-Online-Exams.com

- QUESTION NO : 14

Which statements are correct about the ProLiant warranty service level agreement? (Select two.) A. A travel and labor charge applies when customers decline to replace an optional CSR part. B. A travel and labor charge does not apply when customers decline to replace an optional CSR part. C. A travel and labor charge applies when customers decline to replace a mandatory CSR part. D. A travel and labor charge does not apply when customers decline to replace a mandatory CSR part.

Answer: C Reference:http://h18000.www1.hp.com/products/quickspecs/14226_na/14226_na. pdf(Page 11, Warranty, Note in blue) From datasheet DL380Gen8: A travel and labor charge will result when customers decline to replace a Mandatory CSR part;

- QUESTION NO : 15

Free-Online-Exams.com

What does incremental backup do? A. copies all files that were changed after the last full backup B. backs up all files C. backs up without resetting the archive bit D. copies all files that were changed since the last complete backup and resets the archive bit

Answer: D Reference:http://ask-leo.com/whats_an_incremental_backup.html(an incremental backup)

- QUESTION NO : 16

Which statement is correct? A. The mandatory CSR guideline applies to customers who upgrade their warranty support to carepack or contract maintenance. B. The mandatory CSR guideline does not apply to customers who upgrade their warranty support to carepack or contract maintenance. C. Mandatory and optional CSR guidelines only apply to a product with a warranty service level agreement. D. The optional CSR guideline does not apply to customers who upgrade their warranty support to carepack or contract maintenance.

Free-Online-Exams.com

Answer: C Explanation:

- QUESTION NO : 17

What does differential backup do? A. backs up files since the last full backup, but does not reset the archive bit B. backs up all files C. copies all files that were changed since the last incremental backup D. copies all files changed after the last backup and resets the archive bit

Answer: A Explanation:

- QUESTION NO : 18

When populating memory slots in a DL380 G7 server, which rule must be followed? A. Use white DIMM slots first with installed processors. B. Only one 16 GB PC3-10600 DIMM per channel is allowed. C. PC3L DIMMs must precede PC3 DIMMs in physical location. D. Install DIMMs starting with the nearest slot to the processor.

Free-Online-Exams.com

Answer: A Reference:http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp? lang=en&cc=bg&ta skId=120&prodSeriesId=4091412&prodTypeId=15351&objectID=c02215414( Second bulleted point on the page)

- QUESTION NO : 19

An engineer needs to mount an HP IP KVM G2 switch in an HP 10842 G2 rack. The rack does not contain a console. The customer does not want this switch to be mounted in a place that can be used by a server. What is the best method for mounting the switch? A. Use the standard mount method to mount the switch in the rack at the back side. B. Use the standard mount method to mount the switch in the rack at the front side. C. Use the side mounting brackets to mount the switch in the rack at the left side. D. Mount the switch at the top of the rack at the front side.

Answer: D Explanation:

- QUESTION NO : 20

Free-Online-Exams.com

What is the first step when creating a NIC team using NCU? A. Select team members. B. Configure the team IP address. C. Set IP of each NIC to be used in the team. D. Choose team type.

Answer: A Explanation:

- QUESTION NO : 21

What does adding the battery or flash backed cache upgrade NOT enable? A. RAID 60 migration B. array expansion C. logical drive extension D. stripe size migration

Answer: A Explanation:

- QUESTION NO : 22

Free-Online-Exams.com

An engineer needs to add two Extended Runtime Modules (ERM) on an existing HP R7000 UPS. How does the engineer need to configure the R7000 UPS with the extra available battery runtime? A. In HP Power Manager, log on and click on the Setup tab to update the number of ERMs. B. In HP Power Protector, log on and click on the R7000. Configure the power source and update the number of ERMs. C. Use the OCP of the R7000 and configure the R7000 with two extra ERMs. D. Connect the sense and ERM cable from the first ERM to the UPS and from the second ERM to the first ERM. The R7000 will update the number of ERMs automatically.

Answer: A Explanation:

- QUESTION NO : 23

Where can the server PSP be chosen for version comparison and updates? A. VCEM B. SIM VCRM C. SMH D. VCA

Free-Online-Exams.com

Answer: D Explanation: A: Virtual Connect Enterprise Manager is definately wrong. B: Version Control Repository Manager. (Contains the comparison version) C: System Management Homepage (SMH) is used to get to the VCA. D: Version Control Agent (VCA) is where you set the version baseline to compare to.

- QUESTION NO : 24

HOTSPOT Match each Smart Array controller rebuild rate with its description. see exhibit below,,,

Answer: see exhibit below,,, Explanation: see exhibit below,,, Macintosh HD:private:tmp:skitched-20120717-002113.png

Free-Online-Exams.com

- QUESTION NO : 25

A customer has a DL380p Gen8 base unit with 1 CPU, 4 x 16 GB RDIMM with 24 total DIMM slots. Which memory option is valid? A. Remove the existing memory and populate all memory slots with UDIMMS memory. B. Populate the remaining 20 memory slots with additional RDIMM memory. C. Populate another 8 memory slots with additional RDIMM memory. D. Populate the remaining 20 memory slots with additional UDIMM memory.

Free-Online-Exams.com

Answer: C Explanation: 1CPU can only have half of it's DIMMs active so 12 DIMMs (4+8=12)

- QUESTION NO : 26

While installing an R7000 UPS, an engineer is asked to mount a ground bonding wire to the R7000. Referring to the exhibit, what is the intended ground wire connection point? see exhibit below,,, A. item 7 B. item 9 C. item 10 D. item 11 E. item 12 F. item 16

Free-Online-Exams.com

Answer: B Reference:http://h10032.www1.hp.com/ctg/Manual/c02949494.pdf(page 7)

- QUESTION NO : 27

Free-Online-Exams.com

An engineer is installing a new quad 1 GB NIC in a ProLiant DL360 G7 server. This server already has a full length PCIe card installed. What must the engineer do to install the new NIC? A. Install the half-height NIC version only. B. There are insufficient slots in the server to support the new card. C. Replace the full-height bracket with the supplied half-height bracket. D. Install the NIC in the slot used by the full-length card and then install a half-height bracket on the full-length card.

Answer: A Explanation: Checked only small form factor available and there are quad ports that fit.

- QUESTION NO : 28

HOTSPOT Indicate whether each listed component requires downtime during the DL380p G8 upgrade process. see exhibit below,,,

Free-Online-Exams.com

Answer: see exhibit below,,, Explanation: see exhibit below,,, Macintosh HD:private:tmp:skitched-20120717-005911.png

Free-Online-Exams.com

- QUESTION NO : 29

Free-Online-Exams.com

You have a P421/1GB FBVVC with three hard disks configured as RAID 5. What is the minimum requirement to upgrade the disk's configuration to RAID 60? (Select two.) A. BBWC B. Smart Array Advanced Pack 2.0 C. Fivemore hard disks D. Threemore hard disks

Answer: C Reference:http://www.icc-usa.com/raid-calculator.php RAID60: RAID6 = 2+2, RAID60 = 2*(2+2)=8, 8-3=5

- QUESTION NO : 30

When installing CPUs in ProLiant Gen8 servers, what is used to help an engineer ensure quick, precise, intelligent processor installation? A. HP Intelligent Provisioning B. HP Hot Plug CPU Sockets C. HP CPU Slot Isolation D. HP Smart Socket Guide

Answer: D Reference:http://images10.newegg.com/User-Manual/User_Manual_59-107181.pdf(page 7, 3rd bulleted point)

Free-Online-Exams.com

- QUESTION NO : 31

What are the upgrade options on HP FlexLOM? (Select two.) A. 100Mb/s B. 1 Gb/s C. 10 Gb/s D. 100 Gb/s

Answer: B,C Reference:http://pavt.susu.ru/2012/talks/Yudin.pdf(16th slide, need to count the slides)

- QUESTION NO : 32

An engineer is replacing components in a ProLiant server. When should an ESD strap be used? A. An ESD only needs to be used when working in moist environments. B. An ESD strap needs to be used when working on uncarpeted floors. C. An ESD strap is only needed when static electricity is felt. D. An ESD strap is not needed since ESD protection is built into the components. E. An ESD must always be used when replacing components.

Answer: B,E Explanation:

Free-Online-Exams.com

- QUESTION NO : 33

What is the name of the HP agent that enables a customer to manage HP provided software stored in a user-defined repository? A. Web-Based Enterprise Management (WBEM) B. Version Control Repository Manager (VCRM) C. Version Control Agent D. Data Collection Reports

Answer: B Reference:http://www.hp.com/wwsolutions/misc/hpsim-helpfiles/mxhelp/mxportal/en /sysglossary. html(search VCRM) Verified from documentation "Version Control Repository Manager (VCRM) An HP agent that enables a customer to manage HP provided software stored in a user-defined repository."

- QUESTION NO : 34

HOTSPOT Match each ProLiant RBSU setting with its description. see exhibit below,,,

Free-Online-Exams.com

Answer: see exhibit below,,, Explanation: see exhibit below,,, Macintosh HD:private:tmp:skitched-20120717-012656.png

- QUESTION NO : 35

Free-Online-Exams.com

A ProLiant DL380 Gen8 server has had the system hang over the last two weeks. You contacted HP Technical Support and were asked to send them the Active Health System log for the last two weeks. Where can you download this log? (Select two.) A. ROM Based Setup Utility (RBSU) B. Array Configuration Utility (ACU) C. Intelligent Provisioning Maintenance page D. Integrated Management log (IML) E. iLO information page

Answer: C,E Reference:http://hpproliant.blogspot.com/2012/05/how-to-collect-active-healthsystem-ahs.html

- QUESTION NO : 36

What is used on a Windows server for InfiniBand firmware management? A. VCA B. SMH C. HP SUM D. MFT

Free-Online-Exams.com

Answer: D Reference:http://www.mellanox.com/content/pages.php? pg=management_tools&menu_section=3 4(read the entire page to understand the answer) The Mellanox Firmware Tools (MFT) package is a set of firmware management tools for a single InfiniBand node

- QUESTION NO : 37

After starting HP Insight Diagnostics, you want see how the selected tests are progressing. Which tab should you select? A. Survey B. Status C. Test D. Diagnose E. Help F. Log

Answer: B Reference:http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp? lang=en&cc=us&ta skId=110&prodSeriesId=3857622&prodTypeId=12454&objectID=c01633320(See status tab)

- QUESTION NO : 38

Free-Online-Exams.com

A support engineer needs to replace drives on a ProLiant Gen8 server and must securely erase customer data. How can this be achieved? A. Run the HP System Erase Utility to reset all settings. B. Run the HP System Erase Utility to reset RBSU. C. Run a third-party disk shredding tool. D. Run the HP System Erase Utility to reset all disks.

Answer: D Explanation:

- QUESTION NO : 39

You replaced a Smart Array P812 in a DL380 G7 storage server. What should you do next? A. Verify that the firmware level is current. B. Install the BBWC battery. C. Check the FBWC charge. D. Replace the cache module.

Answer: A Explanation:

- QUESTION NO : 40

Free-Online-Exams.com

A customer has placed a service call because RAID 6 cannot be configured on a Smart Array P420i controller using 4 disk drives. What is the most likely cause of the problem? A. The customer needs a minimum of 6 disk drives to support RAID 6. B. The battery backed cache option is not installed. C. The P420i is Smart Array Controller is defective. D. The P420i Smart Array Controller does not support RAID 6.

Answer: B Explanation:

- QUESTION NO : 41

A support engineer is attending a call out for a DL360P Gen8 Server, where a hard disk within a four disk RAID 5 set has failed. The engineer notices that on three of the drives, the LED labeled D on the exhibit is on. What does the condition indicate? see exhibit below,,, SELECT ALL CHOICES THAT ARE CORRECT: A. Hot swapping of the failed drive is not supported in this condition. B. The LED indicates both failure and predictive failure alerts; therefore, two additional drives in the RAID set are at risk of failing and need to be replaced. C. The drive failure has corrupted three drives in the RAID set. The array will need to be rebuilt and data restored from backup. D. Do not remove the drives with this LED on.

Free-Online-Exams.com

Answer: A,D Reference:http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp? lang=en&cc=us&ta skId=120&prodSeriesId=5177953&prodTypeId=15351&objectID=c03245333(drive LED definitions)

- QUESTION NO : 42

Free-Online-Exams.com

What must you consider when installing redundant fans? A. Locate the fans as specified in the server's documentation. B. Locate redundant fans on the side of the CPU. C. Locate the fans on the memory side. D. Place redundant fans in any location.

Answer: A Explanation:

- QUESTION NO : 43

What is required by iLO to support Agentless management? (Select two.) A. System Location B. SNMP Alert Destination C. Read Community D. Write Community E. Trap Community

Answer: B,C Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03306157/ c03306157.pd f(page 7, Configuring HP agentless management manually, see 2ndand 4thbulleted point. Note that trap community is an optional setting)

- QUESTION NO : 44

Free-Online-Exams.com

When installing a rack in a data center, which way should the racks face? A. Install front to back facing a hot aisle. B. Install back to front facing a hot aisle. C. Install front to front facing a cold aisle. D. Install front to back facing a cold aisle.

Answer: C Explanation: Datacenters have cool lanes and hot lanes. Hot lanes have the backsides of servers facing. Cool lanes have the fronts facing. Front to back or Back to front is always wrong. 1 answer remains.

- QUESTION NO : 45

Your customer's HP Integrity rx2800 i2 server fails to complete self-test. What can you check to find the root cause of the problem? (Select two.) A. Active Health Logs B. System Insight Display LEDs C. Forward Progress Logs D. Early Video Progress Indicators E. UEFI Shell info all output

Answer: A,B Explanation:

Free-Online-Exams.com

- QUESTION NO : 46

Which tool provides the most inclusive information about a server? A. insight Diagnostics online survey B. OS and application logs C. Insight Diagnostics offline survey D. HPS Report

Answer: C Explanation:

- QUESTION NO : 47

What are common types of virtualization? (Select two.) A. cooling B. power C. software D. client E. server

Answer: D,E Explanation:

Free-Online-Exams.com

- QUESTION NO : 48

While the system is online and the OS is operating, the HP Insight Diagnostics Diagnose feature performs diagnostics testing on which devices? A. network interface cards only B. memory and processors only C. hard drives attached to an HP Smart array Controller and power supplies considered diagnosable D. memory, processors, and network interface cards

Answer: C Reference:http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c 00293061/c0029306 1.pdf(page 18, see using the diagnose tab)

- QUESTION NO : 49

A customer asks you to check on the remaining life of the solid state disk drives. Where can you access the SMARTSSD Wear Gauge? A. Array Configuration Utility (ACU) B. iLO home page C. Option ROM Configuration for Arrays (ORCA) D. Integrated Management log (IML)

Free-Online-Exams.com

Answer: A Reference:http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp? objectID=c032488 78&lang=en&cc=us&taskId=101&prodSeriesId=5177957&prodTypeId=15351(Array configuration utility, see 9thbulleted point) HP Solid State Drives are equipped with tools that can report the amount of lifetime remaining. Introducing HP SMARTSSD Wear Gauge. In order to take advantage of SMARTSSD Wear Gauge, Smart Array Firmware version 5.0 or greater is required and HP Array Configuration Utility (ACU) or HP Diagnostic Utility (ADU) must be running.

- QUESTION NO : 50

Which UEFI command is used to back up and store the NVRAM variables of a HP Integrity rx2800 i2? A. nvrambkp -f B. dmpstore -s <filename> C. efi_backup -s fs0: D. drvcfg -s <drv> <ctl>

Free-Online-Exams.com

Answer: B Reference:http://www.scribd.com/doc/74756972/HP-Integrity-Rx2800-i2 -Server-User-Servicec02621256( page 143, see dmpstore) dmpstore is the only command able to work with the NVRAM

- QUESTION NO : 51

A processor failed and was replaced in an HP Integrity rx2800 i2 server. Which UEFI command should be used to verify that the new processor is active and, if needed, may be used to activate it? A. cpuconfig B. info cpu C. activate cpu D. dump fru

Answer: A Reference:http://www.scribd.com/doc/74756972/HP-Integrity-Rx2800-i2 -Server-User-Servicec02621256( page 120, see the note) From the EFI Shell environment, use the cpuconfig command to configure or deconfigure processors

- QUESTION NO : 52

Free-Online-Exams.com

A customer has an HP Integrity rx2800 i2 server with one processor and two memory risers, each with four DIMMs. The customer added an additional memory riser with four memory DIMMs, but cannot see the additional memory at the operating system level. The customer already swapped the first memory riser with the new one, but there is no change. What could cause this issue? A. One of the new DIMMs is faulty. B. The new memory riser is faulty. C. An additional license is needed for using more than two memory risers. D. An additional processor is needed for using more than two memory risers.

Answer: D Explanation:

- QUESTION NO : 53

Free-Online-Exams.com

The system board of an HP Integrity rx2800 i2 server needs to be replaced. Which statements are correct? (Select two.) A. If a Trusted Platform Module (TPM) is installed on the original system board, order and install a new TPM for the new system board. B. Use the UEFI shell SYSSET command to check and correct system settings, such as serial number, after the replacement. C. If no Trusted Platform Module (TPM) is installed on the original system board, make sure you remove it from the new system board, as it comes with a TPM installed. D. If a Trusted Platform Module (TPM) is installed on the original system board, take over the the original TPM to the new system board. ] Use the iLO/MP SYSSET command to check and correct system settings, such as serial number, after the replacement. E. Use the iLO/MP SYSSET command to check and correct system settings, such as serial number, after the replacement.

Answer: D,E Explanation:

- QUESTION NO : 54

Free-Online-Exams.com

You replaced a system board on an HP Integrity rx2800 i2 Server. Which iLO command menu option is used to re-enable network connection options, such as telnet and Web SSL? A. SA: Set MP Access B. LS: LAN Security C. SO: Security Options D. LC: LAN Configuration

Answer: A Reference:http://bizsupport1.austin.hp.com/bizsupport/TechSupport/Document.jsp? objectID=c026 42613&printver=true(see Configuring the iLO3 MP LAN using the RS-232 serial port) The SA command configures the access mode for the LAN and the Command mode. You can set iLO 3 to enable web or SSH access.

- QUESTION NO : 55

A customer has a hard drive with a flashing amber fault indicator in a RAID 5. What is a recommended step in this repair? A. Reseat the failed drive. B. Hot swap the flashing drive and replace it with a new drive. C. Use the RAID utility to force the drive failure. D. Down the server and install a new hard drive.

Free-Online-Exams.com

Answer: B Explanation:

- QUESTION NO : 56

A memory DIMM of an HP Integrity rx2800 i2 server failed and was deconfigured. You replaced it. Which statement is correct? A. The new memory DIMM will still be deconfigured. You have to reconfigure it with the UEFI memconfig command. B. The new memory DIMM will be reconfigured automatically by the firmware. There is no command at UEFI shell to configure DIMMs. C. The new memory DIMM will still be deconfigured. You have to reconfigure it with the UEFI dimmconfig command. D. The new memory DIMM will be reconfigured automatically by the firmware. You can use the UEFI dimmconfig command to check and configure DIMMs. E. The new memory DIMM will be reconfigured automatically by the firmware. You can use the UEFI memconfig command to check and configure DIMMs.

Answer: E Explanation:

- QUESTION NO : 57

Free-Online-Exams.com

After the system board of an HP Integrity rx2800 i2 is replaced, which tool is used to set the mode of the SAS controller? A. IOCONFIG B. SAUTIL C. ORCA D. SAUPDATE

Answer: D Reference:http://www.scribd.com/doc/74756972/HP-Integrity-Rx2800-i2 -Server-User-Servicec02621256# outer_page_138(page 131, see caution) The saupdate command is used to query or change the mode of the Smart Array P410i. http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp? objectID=c03441260&lang=en&cc=us&taskId=&prodSeriesId=5033573&prodTypeId =15351

- QUESTION NO : 58

HP Support asked you to upgrade the firmware on the new DL380 Gen8 server you are installing at a customer's site. Which software tool can you use to do this? A. HP Firmware Maintenance CD B. HP Array Diagnostic Utility C. HP Service Pack for ProLiant D. most recent SmartStart CD for ML/DUSL ProLiant servers

Free-Online-Exams.com

Answer: C Reference:http://h18004.www1.hp.com/products/quickspecs/14212_div/14212_div. HTML(see HP insight management software, first paragraph) B is for array diagnostic and wrong answer Use the Service Pack for ProLiant (SPP) at www.hp.com/go/spp to get firmware and software updates. http://h18004.www1.hp.com/products/quickspecs/14212_div/14212_div.HTML

- QUESTION NO : 59

What are features of Option ROM Configuration for Arrays (ORCA)? (Select two.) A. drive expansion B. ability to set the stripe size C. RAID level migration D. online spare assignment E. Smart Array Advanced Pack license registration

Answer: D,E Reference:http://www.scribd.com/doc/74756972/HP-Integrity-Rx2800-i2 -Server-User-Servicec02621256# outer_page_140(page 140, 141 and 142) http://www.informit.com/articles/article.aspx?p=359414&seqNum=2

- QUESTION NO : 60

Free-Online-Exams.com

How do you enter the RBSU on Post? A. F8 B. F9 C. F11 D. F12

Answer: B Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01804533/ c01804533.pd f(page 9, see Using RBSU to reconfigure BIOS)

- QUESTION NO : 61

What is the default port to use to access the System Management Homepage with Internet Explorer for a ProLiant Server? A. 2301 B. 2321 C. 2381 D. 2391

Answer: C Reference:http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c 00293061/c0029306 1.pdf(page 10, see Starting the Online Edition from a browser, bulleted point#2)

Free-Online-Exams.com

- QUESTION NO : 62

You need to replace one of the processors in a dual processor ProLiant Server. Which processor should become the primary processor? A. the server will choose it automatically on next power-on. B. the new processor C. the processor with the highest stepping D. the processor with the lowest stepping

Answer: C Explanation: http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00280248/c00280248 .pdf?jumpid=reg_R1002_USEN C-32

- QUESTION NO : 63

How can you validate the installed firmware versions on an HP Integrity rx2800 i2 server? (Select two.) A. Check the FW Revisions tab in the iLO web GUI. B. Use the fw command on the iLO. C. Check the firmware information in the Virtual Front Panel (VFP) on the iLO. D. Check the firmware information in the UEFI main menu. E. Use the sysrev command on the iLO.

Free-Online-Exams.com

Answer: A,E Explanation: E is correct an A http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03207602/c03207602 .pdf (Access management information) VFP only has leds

- QUESTION NO : 64

The firmware was just updated on an HP Integrity rx2800 i2. Which command is used to determine if any firmware is in a pending state? A. sysset B. sysrev C. df-all D. info fw

Answer: B Explanation: To verify if a system FW update is pending, run the iLO3 MP SYSREV command and check if the Pending column shows any version for System FW. ftp://15.216.110.139/ftp2/pub/softlib2/software1/doc/p391819069/v82662/rx2800 _Linux_26.35.htm

- QUESTION NO : 65

Free-Online-Exams.com

You are working on an HP ProLiant DL380 G7. HP Support wants you to send them a copy of the survey that captures detailed information about the server. How do you generate this file? A. During boot up, press the F10 key when prompted. B. Run Insight Diagnostics. The survey runs automatically. Navigate to the Survey tab, and save the survey to a USB memory flash drive. C. Boot SmartStart, navigate to the Software tab, and choose Server Documentation. D. During boot up of the server, press the F8 key when prompted.

Answer: B

- QUESTION NO : 66

Where is the data written when power is lost on a Smart Controller A. network controller B. flash backed write cache C. system memory D. master boot record

B http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00687518/c00687518 .pdf

Free-Online-Exams.com

- QUESTION NO : 67

HP Support asked you to load diagnostics from a SmartStart CD to evaluate a DL360 G6 server. The customer removed the DVD drive and installed the optional disk backplane to add more disk drives. With no DVD drive available, how can you load the diagnostics? A. Remove the additional disks and replace the DVD drive until service is completed. B. Nothing can be done without a CD/DVD drive installed on the server. C. Make a bootable USB key drive with the SmartStart ISO on it. D. Make multiple floppy disks from a the SmartStart image for floppies.

C No floppy support, done it myself using usb, A is too much work and you cant be sure all components are updated.

Das könnte Ihnen auch gefallen