DIAL SIZE
MODEL NPT
" * " " " " " " " " " " " " " " " " " " " " " " " " " " "
CASE
304 STAINLESS STEEL
RANGES
Up to 10,000 psi
OTHER FEATURES
* Full blow-out protection * Repairable * Lexan Lens * Weather Tight Case * Compensating diaphragm MOUNTING STYLES: Bottom, Center-back (1), U-Clamp, Panel mount * Utility Gauge * Polycarbonate Lens
1.5%
Grade A
Fillable
304 STAINLESS STEEL
(2)
BRASS
Non-Fillable
BLACK ENAMELED STEEL
3-2-3%
Grade B
Up to 5,000 psi
* Economical McDaniel Quality * Restrictor screw for pulsation dampening MOUNTING STYLES: Bottom, Center-back, U-Clamp, Panel mount
Non-Fillable
304 STAINLESS STEEL
(3)
316 STAINLESS STEEL
1%
Grade 1A
Fillable
304 STAINLESS STEEL
(2)
Up to 15,000 psi
* Laminated Safety Glass Lens * Repairable * Weather Tight Case * Blow-out disc MOUNTING STYLES: Bottom, Center-back , U-Clamp, Panel mount * Utility Gauge
BRASS
Filled**
304 STAINLESS STEEL
* Polycarbonate Lens
3-2-3%
Grade B
Up to 5,000 psi
Non-Fillable
BLACK ENAMELED STEEL
(3)
Non-Fillable
304 STAINLESS STEEL 316 STAINLESS STEEL
Fillable
304 STAINLESS STEEL
(2)
Up to 20,000 psi
BRASS
1%
Grade 1A
* * * * *
Laminated Safety Glass Lens Repairable Weather Tight Case Restrictor screw for pulsation dampening Solid Front Blow-out Back Case Available
Fillable
CAST BRASS
MOUNTING STYLES: Bottom, Lower-back, U-Clamp, Panel mount, Rear Flange, Center-Back available by special order. * Laminated Safety Glass Lens * Repairable * One-piece case and stem * Heavy-duty MOUNTING STYLES: Bottom, Center-back , U-Clamp * Polycarbonate Lens * Restrictor Screw * Rolled Threads * Welded Case and Stem MOUNTING STYLES: Bottom, Lower-back , U-Clamp, Front Flange, Rear Flange * Utility Gauge * Polycarbonate Lens * Economical McDaniel Quality * Restrictor screw for pulsation dampening MOUNTING STYLES: Bottom, Center-back, U-Clamp, Panel mount
Fillable
304 STAINLESS STEEL
(3)
316 STAINLESS STEEL
2-1-2%
Grade A
Fillable
304 STAINLESS STEEL
(2)
BRASS
Filled**
3-2-3%
Grade B
Non-Fillable
BLACK ENAMELED STEEL
(3)
Non-Fillable
**FILLED GLYCERIN ACCURACY ASME B40.1
*SPECIAL NON-STOCK
(1) RANGE Includes: Vacuum, (2) (3) Compound, and Receiver 3-15
Model S 1/4 NPT only in Back connection 316 SS Tube, Tip and Socket Brass Socket, Copper Alloy / Phosphorous Bronze Tube and Tip
Page 1
DISTRIBUTED BY:
M C
DIAL SIZE
MODEL NPT
A C E G L M N P E9 G9 MCXA MCXC MC3A MC3C
"
CASE
304 STAINLESS STEEL
INTERNALS ACCURACY
RANGES
* * * * * * * * *
OTHER FEATURES
Laminated Safety Glass Lens Repairable Adjustable Pointer No pointer stop on dial Pulsation Dampened Full blow-out Relief Vacuum Stop Overrange Stop Weather Tight Case
316
STEEL
(2)
Fillable
POLYAMID B
.5%
Grade 2A
(100 mm)
4"
BRASS*
MOUNTING STYLES: Bottom, Lower-back, U-Clamp, Panel mount with Front Flange, Rear Flange (MODELS: E, G) (also 6 MODELS F, H) Solid Front/Blow-out Back configuration available .5% accuracy ranges 15 psi to 10,000 psi 1.5% accuracy ranges 6 wc to 250 wc 1.0% accuracy ranges above 10,000 psi
(3) Fillable
304 STAINLESS STEEL
2-1-2%
Grade A
Fillable
304 STAINLESS STEEL
(2)
316 STAINLESS STEEL
* Polycarbonate Lens * Welded Case and Stem * Rolled Threads * Threaded Inlet - Restrictor Screw Ready MOUNTING STYLES: Bottom, Center-back , U-Clamp, Front Flange, Rear Flange * * * * * * * Laminated Safety Glass Lens Repairable Weather Tight Case Capsule Sensing Element 20 times Overrange Protected Precision Geared Movement Vacuum and Compound Ranges Available
(2)
BRASS
1.5%
Grade A
(3)
MOUNTING STYLES: Bottom, Lower-back,Panel mount, Rear Flange * Laminated Safety Glass Lens * Repairable * Adjustable Pointer * Compensating Diaphragm-Elastomer with internal O ring seal * Field ready for filling, hermetically sealed, weatherproof. No fill kit required. * Solid Front/Blow-out Back MOUNTING STYLES: Bottom Connected Only * Laminated Safety Glass Lens * Repairable * Adjustable Pointer * No pointer stop on dial * Pulsation Dampened * Full blow-out Relief * Vacuum Stop * Overrange Stop * Weather Tight Case MOUNTING STYLES: Bottom, Lower-back, U-Clamp, Panel mount with Front Flange, Rear Flange (MODELS: F, H Bottom Connect Only) Solid Front/Blow-out Back configuration available
4" MPB/SC
(130 mm)
MPB/SA B D F H Y Z MCXB
Fillable
304 STAINLESS STEEL
(2)
.5%
Grade 2A
(160 mm)
6"
Fillable
POLYAMID B
BRASS*
Non-Fillable
304 STAINLESS STEEL
(3)
316 STAINLESS STEEL
(2)
BRASS
1.5%
Grade A
2.5160 WC 1.6160 WC
* * * * * * *
Laminated Safety Glass Lens Repairable Weather Tight Case Capsule Sensing Element 20 times Overrange Protected Precision Geared Movement Vacuum and Compound Ranges Available
" Non-Fillable
(3)
ACCURACY ASME B40.1
RANGE (2) Includes: Vacuum, (3) Compound, and (4) Receiver 3-15
M C
RANGE CODE 3 5 6 10 A B C D E F G H I J K L M N 4k O 6k P Q R 30k 35k 40k 50k 60k S T U V W X Y 2k Z
RANGE GUIDE
= NOT AVAILABLE THIS RANGE
RANGE (psi) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 5 6 10 15 30 60 100 160 200 300 400 600 800 1,000
0 - 1,500 0 - 2,000 0 - 3,000 0 - 4,000 0 - 5,000 0 - 6,000 0 - 10,000 0 - 15,000 0 - 20,000 0 - 30,000 0 - 35,000 0 - 40,000 0 - 50,000 0 - 60,000 VAC 30Hg - 0 REC 3 - 15 COMP 30Hg + 15 COMP 30Hg + 30 COMP 30Hg + 60 COMP 30Hg + 100 COMP 30Hg + 160 COMP 30Hg + 200 COMP 30Hg + 300
R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8 R8
S S S S S S S S S S S S S S S S S S S S2 S S S S S S S S S S S S S S S S S S S
T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T61 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6
T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7 T7
T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8 T8
U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U
Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y2 Z2 Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z
(1 1K = To avoid duplicate part numbers, use 1K when specifying 0-1000 psi range on models J6 and T6) (2 4K = 4,000 psi range, non-stock, special order for: Models A, B, C, D, E, F, G, H, MPB, S, Y, Z)
To order mercury, Feet of Sea water, or special ranges, describe the desired range, after the MODEL type.
EXAMPLE:
O = S = G =
Model K
Order: A 2 sealed gauge with a scale of 0 to 100 psi, panel-mounted / front flange, NPT lower-back connection, filled at factory with glycerin (KDP-GF).
C L P U R *
= = = = = =
RANGE CODE
1.6 2.5 4 6 10 16 25 40 60 100 160 200 250 1.6 - 0 2.5 - 0 4 - 0 6 - 0 10 - 0 16 - 0 25 - 0 40 - 0 60 - 0 100 - 0 160 - 0 200 - 0 250 - 0
RANGE Inches of
Water Column (H2O)
0 0 0 0 0 0 0 0 0 0 0 0 0 VAC 1.6 VAC 2.5 VAC 4 VAC 6 VAC 10 VAC 16 VAC 25 VAC 40 VAC 60 VAC 100 VAC 160 VAC 200 VAC 250
MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA MCXA
MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB MCXB
MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC MCXC
MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD MCXD
Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z
To order mercury, Compound Inches of Water, or other ranges, describe the desired range, (rather than use a range code) after the MODEL type. This range guide illustrates McDaniel gauge model ranges. Some model ranges are not stocked. Minimum order quantites may apply. *Models J7 and J8 low pressure ranges: 0-3, 0-5, 0-10 PSI and Inches of H20 are special order, non-stock.
Note For Compound Inches of Water Column (H2O) Ranges and Gauge Model availability: Find the gauge model/type from the McDaniel Gauge Selection Guide, and with your desired compound range, add together the vacuum (negative) and pressure (positive) side. If the sum of the two added together equals a range for a model in table above, then the compound range is available. (e.g. desired range: 50050 WC, in gauge model A. Model A is availible in 0-100. 50050 adds up to 100 WC. Your compound range could be 70030, 30070, or 60040, etc.)
To convert pressure for one unit to another: 1. Start at column heading with units to convert from. 2. Move down the same column to number 1. 3. Move across this row to the clolumn with units heading you are converting to. 4. Multiply the number in this table cell times the amount you are converting from to get the new value in converted
psi 1 14.7 0.0361 0.001421 0.01421 0.0625 14.22 0.4912 0.01934 0.1934 0.0145 14.504 0.000145 0.14504 145.04 Page 4 atms 0.0681 1 0.00246 0.000097 0.000967 0.00425 0.968 0.03342 0.001316 0.01316 0.000987 0.987 0.00001 0.00987 9.869 H2O 27.71 407.2 1 0.0394 0.3937 1.732 394.1 13.61 0.536 5.358 0.4012 401.9 0.00402 4.019 4019 mm H2O 703.8 10,343 25.4 1 10 43.986 100,010 345.7 13.61 136.1 10.21 10,210 0.102 102.07 102,074 cm H2O 70.38 1,034.3 2.54 0.1 1 4.40 1,001 34.57 1.361 13.61 1.021 1021 0.0102 10.207 10,207 oz/in2 16 235.1 0.5775 0.0227 0.227 1 227.6 7.858 0.310 3.10 0.2321 232.1 0.00232 2.321 2321 Kg/cm2 0.0704 1.033 0.00254 0.0001 0.001 0.0044 1 0.0345 0.00136 0.0136 0.00102 1.02 0.00001 0.0102 10.2 Hg 2.036 29.92 0.0735 0.00289 0.0289 0.1273 28.96 1 0.0394 0.394 0.0295 29.53 0.000295 0.295 295.3 mm Hg (Torr) 51.715 760 1.866 0.0735 0.735 3.232 735.6 25.4 1 10 0.75 750 0.0075 7.5 7500 cm Hg 5.17 76 0.187 0.00735 0.0735 0.3232 73.56 2.54 0.1 1 0.075 75 0.00075 0.75 750 mbar 68.95 1013 2.488 0.098 0.98 4.31 980.7 33.86 1.333 13.33 1 1,000 0.01 10 10,000 bar Pa (N/m2) kPa 6.895 101.3 0.249 0.0098 0.098 0.431 98.07 3.386 0.1333 1.333 0.1 100 0.001 1 1,000 MPa 0.0069 0.1013 0.00025 0.00001 0.0001 0.00043 0.0981 0.00339 0.000133 0.00133 0.0001 0.1 0.000001 0.001 1
GMSG0802
0.0689 6,895 1.013 101,325 0.00249 248.8 0.000098 9.8 0.00098 98 0.00431 431 0.981 98,067 0.0339 3,386 0.001333 133.3 0.01333 1,333 0.001 100 1 100,000 0.00001 1 0.01 1,000 10 1,000,000