6.0 Particular Methodology.

6.7 6.7.1 Building Painting Work Material The term paint and/or painting, as used herein, means all coating systems materials including stains, varnishes, primers, emulsions, epoxy, enamels, sealers, fillers and other applied materials whether used as prime, intermediate, or finish coats. a) Emulsion paint system for interior surfaces will be acrylic resin based polymer emulsion, DNT Super V-Tex Emulsion paint. Packed size: 20 liter. b) Gloss paint system for timber and metal item will be DNT V-Enamel paint, alkyd resin based gloss finish paint. Packed size: 5 liter. c) Waterproofing coating system for exterior wall will be DNT Carboflex coating system. Packed size: 20 liter. d) Specialty Floor coating will be BASF Mastertop 1080 for epoxy floor coating and BASF Mastertop 1110 for liquid floor hardener and anti-acid painting.

6.7.2

Installation General a) Seal and otherwise prepare as necessary surfaces to receive new coat of paint as specified on the Drawings. b) All surfaces will be painted as a complete system using materials from the same manufacturer unless approved otherwise in writing. c) Submit finishing schedule and color chart for prior approval. Upon selection of colors and glosses, to provide two samples of each color and gloss for the coating system specified to be applied. Sample boards will be approximately 30 cm square with finishes staggered to expose each coat. d) Applicator will inspect the installed work of all other trades and verify that all such work is complete to the point where painting may properly commence. e) Applicator will wear proper PPE and use such equipment/tools to mix and prepare paint material as per application instructions provided by the respective manufacturers. f) All removable items which are in place and are not designated to receive paint finish will be removed and/or provide with surface-applied protection prior to surface preparation and painting operations. Following completion of painting in each space or area, the respective trade will reinstall the removed items.

g) Plaster will be allowed to dry out completely within 21 days or less. Painting will not be done in rain, fog, or mist; or to damp or wet surfaces. Painting of wood surfaces will not proceed until the moisture content of the wood is 15% or less as measured by a moisture meter.

h) Store materials not in actual use in tightly covered containers and maintain containers used in storage, mixing, and application of paint in a clean condition, free from foreign materials and residue.

Areas / Surfaces Not Requiring Painting a) Unless otherwise indicated, painting is not required on surfaces in concealed areas and inaccessible areas such as furred spaces, foundation spaces, utility tunnels, pipe spaces, and duct shafts. b) Metal surfaces of anodized aluminum, stainless steel, chromium plate, copper, bronze, and similar finished materials will not require painting under this section except as may be specified herein. c) Do not paint any moving parts of operating units, mechanical or electrical parts such as valve operators, linkages, shrinkages, sensing devices and motor shafts, unless otherwise indicated. d) Do not paint over any required labels or equipment identification, performance rating, name or nomenclature plates.

Surface Preparation

a) All preparation and cleaning procedures will be performed in strict accordance with the manufacturer's instructions and procedures first described under General section. b) Clean each surface to be painted prior to applying paint or surface treatment. Remove oil and grease with clean cloths and cleaning solvents of low toxicity and a flash point in excess of 38 degrees C (100 degrees F), prior to start of mechanical cleaning. c) Schedule the cleaning and painting so that dust and other contaminants from the cleaning process will not fall onto wet newly painted surfaces. Plaster, cement board and other board, masonry block and brick Surfaces will be clean and free from dirt, efflorescence and excess mortar using stiff bristle brush. Cleaning solutions will not be used.

Wood surfaces Smooth all finished wood surfaces exposed to view, using varying degrees of coarseness in sandpaper to produce a uniformly smooth and unmarred wood surface. A final grit size of 4/0 or finer will be used. All sanding shall be done parallel to the grain of the wood. No cross-grain standing marks will be admissible for any finish system on solid wood members. Repair and fill rough surfaces with approved wood filler and allowed to dry before sanding flush with 4/0 abrasive paper.

Metal surfaces Clean all surfaces until they are completely free from dirt, oil, grease, and rust. Remove rust by wire brushing or appropriate commercial rust remover.

Paint Preparation Generally mix and prepare painting materials in strict accordance with the manufacturer's instructions. Stir all paint materials before application to produce a mixture of uniform density, and as required during application of the paint materials. Remove any film which may have form on the surface and if necessary to strain the paint material before using.

6.7.3

Paint System. DNT Super V-Tex Emulsion Paint System / Interior Surfaces. Item Description DFT Recoating Application method / Theoretical Coverage (micron) interval. (30deg C) 1 Sealer coat x 1. Alcose HS150, Styrenated-acrylic copolymer, water based. Color=white. Base coat x 1. Super V-Tex, emulsion Color=color chart. Finishing coat x 1. Super V-Tex, emulsion Color=color chart. 30 2 1/2 hr Roller, 16m2 per liter

Remark

Thinner=water, Ratio: 0 10%

25 - 30

1 hr

Roller, 16m2 per liter

Thinner=water Ratio: 10-25% Thinner=water Ratio: 10-25%

25 - 30

1 hr

Roller, 16m2 per liter

DNT Carboflex Coating System / Exterior Surfaces. DFT Recoating Item Description (micron) interval. (30deg C) 1 Sealer coat x 1. 40 2 hrs Carboseal S, acrylic resin based. Color=white. 2 Base coat x 1. 200 4 hrs Carboflex, resin rich flexible mastic. Color=whitish clear. 3 Finishing coat x 2. 45 each 4 hrs Carboshine #100, coat acrylic, water-based. Color=pastel shades. 3

Application method/ Theoretical Coverage Roller, 10-16m2 per liter

Remark

Roller, 2.4m2 per liter

Thinner= Carboseal S Thinner Ratio:0 10% Thinner=water Ratio: 0 10%

Roller, 12m2 per liter per coat.

Thinner=water Ratio: 5% max

DNT V-Enamel Gloss Paint System / Wood & Metal Surfaces. Item Description DFT Recoating Application method/ (micron) interval. Theoretical Coverage (30deg C) 1 Sealer coat x 1. V-undercoat, alkyd resin based. Color=white & pastel shades. Base coat x 1. V-Enamel, high gloss. Color=color chart. Finishing coat x 1. V-Enamel, high gloss. Color=color chart. 35 10 hrs Brush, 15m2 per liter.

Remark

Thinner=DNT Alkyd paint thinner. Ratio: 0 15% Thinner=DNT Alkyd paint thinner. Ratio: 0 10% Thinner=DNT Alkyd paint thinner. Ratio: 0 10%

30

16 hrs

Brush, 17m2 per liter.

30

16 hrs

Brush, 17m2 per liter.

Note: DNT is a trademark of DAI NIPPON TOKYO Co., Ltd

6.7.4

Miscellaneous a) Proper storage will be provided to prevent damage to, and deterioration of paint and coating materials. b) All materials will be delivered to the job site in original, new and unopened containers bearing the manufacturer's name and label showing at least the following information. i) Name or title of the material ii) Spec. number or BS if applicable iii) Manufacturer's stock number iv) Manufacturer's name v) Contents by volume for major constituents vi) Thinning instructions vii) Application instructions

6.7.5

Specialty Floor Coating. Epoxy floor coating, Liquid Floor Hardener and Anti-Acid Paint Coating a) The specialty floor coating will be BASF Mastertop 1080 and Mastertop 1110. b) BASF Mastertop 1080 is a two-component epoxy resin floor coating applied by paint roller directly onto the substrate in accordance with manufacturers instruction. Packed size will be in 5.0L/set and 20L/set. The finish is a hard, durable and glossy film. A separate color pack will be use. Pebble grey and silver grey is suggested.

c) BASF Mastertop 1110 is an advanced water dispersed two-component durable epoxy resin coating applied by paint roller directly onto the substrate in accordance to manufacturers instruction. Packed size will be in 10kg per set. Light grey and dark grey color is suggested for differentiation. 4

d) Substrate to receive the specialty coating will be structurally sound, clean and free from loose particles, oil, grease or any other contaminants. Oil, grease and wax will be removed by scrubbing with industrial grade detergent or degreasing compound, followed by mechanical cleaning using water jet to remove cement laitance, loose particles and other contaminants. e) Prior to application the bond strength of the substrate will be checked with an approved pull-off tester and the reading will be at least 1.5N/mm2. f) Rate of application will be as follows:Product Mastertop 1080 Coating 1st and 2nd coat diluted with 10% approved thinner. 1st coat diluted with 10% water. 2nd & 3rd coat (if required) Rate of Applicable 0.8 1.0 L/m2 Thickness 0.3mm Curing Cycle 18 hrs after 1st coat but not more than 36 hrs. Not applicable, tack dry 24 hrs after completing coating.

Item 1

2 3

Mastertop 1110 Mastertop 1110

0.20 - 0.30 kg/m2 0.20 - 0.25 kg/m2

0.15mm (wft) 015 0.20mm (wft)

Note: Application temperature: min 10 deg C / max 35 deg C. g) The finished floor will be protected for 24 hours after lying from spillage, dust, insects, small animals, foot traffic, rain, moisture, etc. h) Clean up and cleaning of tools will be in accordance to manufacturers instructions.