Sie sind auf Seite 1von 54

Put ON the site analyzer by press & hold ON/OFF button for few second

Screen appear on the display to any one mode in which it was switch off Here mode is fault location , so screen appear on display

Fault Location
Save/Recall Auto Scale Hold VSWR 1.4

1.0
0 Distance(M) 450

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Here we need to change the mode because we measure the VSWR not localize the fault... Press the MODE button & screen change to

Select Mode
Measure match Fault location Measure power

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Select MEASURE MATCH button by pressing selection button & screen change to

Measure match
Save/Recall Auto Scale Hold VSWR 1.4

1.0
1710 Frequency(MHz) 1880

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Here frequency scale is not for GSM900 band so we have to change frequency band Now press CONFIGURATION button & screen change to

Frequency Limit

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Using SELECTION button , select the frequency

VSWR

Start frequency Stop frequency

1710 1880

MHz

MHz

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Select start frequency and stop frequency by using LEFT/RIGHT AROOW button and enter desired frequency by using NUMERIC KEYPAD & press ENTER Now press Esc. And screen change to

Measure match
Save/Recall Auto Scale Hold VSWR 1.4

1.0
890 Frequency(MHz) 960 Calibration OFF

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now here we need to calibration ON

So we need for that calibration kit


To do calibration , press CALIBRATION button

Calibration Short Open Load

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now connect short connector of calibration kit with RF antenna port of the site analyzer
So by using SELECTION button select SHORT screen change to &

Calibration Short Done Open Load

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now remove short connector & connect open connector with RF antenna port of the site analyzer So by using SELECTION button select OPEN & screen change to

Calibration Short Done Open Done Load

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now remove open connector & connect load connector with RF antenna port of the site analyzer So by using SELECTION button select LOAD & screen change to

Measure match
Save/Recall Auto Scale Hold VSWR 1.4

1.0
890 Frequency(MHz) Calibration ON 960

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now remove load connector & connect RF antenna port and Jumper using adaptor
Then press AUTO SCALE & screen change to

Measure match
Save/Recall Auto Scale Hold VSWR 1.4

1.0
890 Frequency(MHz) Calibration ON 960

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

From this graph we dont take exact value of VSWR

For that we need marker on the graph


So activate marker by press MARKER button & screen change to

Marker M1 Activate

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now select activate by using SELECTION button & screen change to

Marker M1 Deactivate

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now press Esc & screen change to

Measure match
Save/Recall Auto Scale Hold VSWR 1.4

M1

1.0
890 M1: 900 1.19 Frequency(MHz) Calibration ON 960

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

We need marker on the pick So press the TOP ARROW button and marker shift to the pick & screen change to

Measure match
Save/Recall Auto Scale Hold VSWR 1.4 M1

1.0
890 M1: 900 1.19 Frequency(MHz) Calibration ON 960

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Here VSWR value is over the acceptable range means fault in transmission line So we have to localize the fault

For that we need change the mode


So press MODE button and select the fault location by using SELECTION button & screen change to

Fault Location
Save/Recall Auto Scale Hold VSWR 1.4

1.0
0 M1: 900 1.19 Distance(m) Calibration ON 450

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

In this screen accuracy of reading is not good So we need to set distance scale So press the CONFIGURATION button & screen change to

Distance Limit

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now select distance by using selection button & screen change to

Distance

meter Start Distance Stop Distance Max Distance 0 450 450

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now select stop distance by using LEFT/RIGHT ARROW button Then enter desired distance by using NUMERIC KEYPAD and press enter

Now press Esc & screen change to

Fault Location
Save/Recall Auto Scale Hold VSWR 1.4

1.0
0 Distance(m) Calibration ON 25

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Here we also need marker for exact location So we have to activate the marker

So press MARKER and select activate using SELECION button & screen change to

Fault Location
Save/Recall Auto Scale Hold VSWR 1.4

M1

1.0
0 M1: 1 1.18 Distance(m) Calibration ON 25

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now press TOP ARROW button and marker on the pick & screen change to

Fault Location
Save/Recall Auto Scale Hold VSWR 1.4 M1

1.0
0 M1: 12 1.37 Distance(m) Calibration ON 25

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now we get fault at exact location

So check that location and rectify fault


Now for save the reading select Save/Recall by using SELECTION button & screen change to

Save Recall Edit Delete JAIPUR -1M 22/12/2011 2.00PM JAIPUR -1M 22/12/2011 2.05PM JAIPUR -1M 22/12/2011 2.10PM

JAIPUR -1M 22/12/2011 2.15PM

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

To save the new reading select save by using SELECTION button & screen change to...

SURAT B 1M K L M N O E J O T Y = + A B C D F G H I K L M N P Q R S U V W X Z Space [ ] * : -

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now enter name and then press Esc


So reading saved & screen change to

Save Recall Edit Delete SURAT B - 1M 25/12/2011 9.15AM JAIPUR -1M 22/12/2011 2.00PM JAIPUR -1M 22/12/2011 2.05PM JAIPUR -1M 22/12/2011 2.10PM

JAIPUR -1M 22/12/2011 2.15PM

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Now arrange all the connection with S.A and sensor 50w element towards O/P direction and 5 w element towards I/P direction Connect S.A with sensor using D-9 serial straight cable Now put ON the S.A

We have to need change the mode


So change the mode to MEASURE POWER & screen change to

Measure power M watt

Warning
Do not apply external power to RF antenna test port

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

After few time screen change to

Measure power DBM 50

0 FWD: 40 watt REF: 0.1 watt

1
4 7 *

2
5 8 0

3
6 9 #

Esc
Enter

Das könnte Ihnen auch gefallen