Sie sind auf Seite 1von 11

103

Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

LOCATION: BASEMENT FLOOR COLUMN

BAR SHAPE

4C18

Bar length

4.55

No. of Bars No. of


on one col. Member

Total No.
of Bars

1.80

23

1.35

23

16

Stirrup (st1)

12

3.00

23

2.10
8

CONTRACTOR:

46

16

20

24

28

32

36.4

41.4

31.05

54.6

69

96.6

23

Stirrup (st2)

14

12

4.55

12

23

4C22

10

23

Stirrup (st2)

16

Stirrup (st1)

LENGTH
6

46

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C29

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

Total No.
of Bars

2.10

23

1.20

23

4.55

2.40

20

1.75

20

4.55

12

3.00

CONTRACTOR:

20

24

28

32

36.4

48.3

27.6

36.4

48

35

54.6

60

12

16

Stirrup (st1)

20

20

4C40

16

20

Stirrup (st2)

14

16

Stirrup (st1)

12

23

4C35

10

23

Stirrup (st2)

16

Stirrup (st1)

LENGTH
6

20

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

Stirrup (st2)

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

2.10

No. of Bars No. of


on one col. Member

20

Total No.
of Bars

4.55

2.40

20

1.75
8

CONTRACTOR:

20

12

14

16

20

24

28

32

42

36.4

48

35

20

Stirrup (st2)

10

16

Stirrup (st1)

20

4C46

LENGTH
6

20

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C51

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

Total No.
of Bars

2.40

20

1.75

20

4.55

2.05

23

1.15

23

4.55

2.05

23

1.15
8

CONTRACTOR:

23

28

32

36.4

48

35

36.4

47.15

26.45

36.4

47.15

26.45

23

Stirrup (st2)

24

16

Stirrup (st1)

20

23

4C62

16

23

Stirrup (st2)

14

16

Stirrup (st1)

12

20

4C57

10

20

Stirrup (st2)

16

Stirrup (st1)

LENGTH
6

23

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C67

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

Total No.
of Bars

2.40

20

1.75

20

4.55

2.40

20

1.75

20

4.55

2.40

CONTRACTOR:

20

24

28

32

36.4

48

35

36.4

48

35

36.4

48

16

Stirrup (st1)

20

20

4C20

16

20

Stirrup (st2)

14

16

Stirrup (st1)

12

20

4C19

10

20

Stirrup (st2)

16

Stirrup (st1)

LENGTH
6

20

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

Stirrup (st2)

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

1.75

No. of Bars No. of


on one col. Member

20

Total No.
of Bars

4.55

2.05

23

1.15

CONTRACTOR:

23

12

14

16

20

24

28

32

35

36.4

47.15

26.45

23

Stirrup (st2)

10

16

Stirrup (st1)

20

4C30

LENGTH
6

23

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C36

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

12

Total No.
of Bars

3.00

20

2.10

20

4.55

2.40

20

1.75

20

4.55

2.40

20

1.75

CONTRACTOR:

20

28

32

54.6

60

42

36.4

48

35

36.4

48

35

20

Stirrup (st2)

24

16

Stirrup (st1)

20

20

4C47

16

20

Stirrup (st2)

14

16

Stirrup (st1)

12

20

4C41

10

20

Stirrup (st2)

12

16

Stirrup (st1)

LENGTH
6

20

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C52

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

12

Total No.
of Bars

3.00

20

2.10

20

4.55

2.05

23

1.15

23

4.55

1.75

23

0.55

CONTRACTOR:

23

28

32

54.6

60

42

36.4

47.15

26.45

27.3

40.25

12.65

23

Stirrup (st2)

24

16

Stirrup (st1)

20

23

4C63

16

23

Stirrup (st2)

14

16

Stirrup (st1)

12

20

4C58

10

20

Stirrup (st2)

12

16

Stirrup (st1)

LENGTH
6

23

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C68

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

Total No.
of Bars

2.40

20

1.75

20

4.55

2.40

20

1.75

20

4.55

12

3.00

20

2.10
8

CONTRACTOR:

20

28

32

36.4

48

35

36.4

48

35

54.6

60

42

20

Stirrup (st2)

24

12

16

Stirrup (st1)

20

20

4C24

16

20

Stirrup (st2)

14

16

Stirrup (st1)

12

20

4C20

10

20

Stirrup (st2)

16

Stirrup (st1)

LENGTH
6

20

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

4C31

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

4.55

No. of Bars No. of


on one col. Member

Total No.
of Bars

2.05

23

1.15

23

4.55

12

3.00

20

2.10

20

4.55

2.05
8

CONTRACTOR:

23

24

28

32

36.4

47.15

26.45

54.6

60

42

36.4

47.15

16

Stirrup (st1)

20

20

4C42

16

20

Stirrup (st2)

14

12

16

Stirrup (st1)

12

23

4C37

10

23

Stirrup (st2)

16

Stirrup (st1)

LENGTH
6

23

CONSULTANT:

103
Shop Drawings

ITP/SD/.

IT PARK INCUBATION BUILDING

Date : Dec. 26, 2011

Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING

Shop drawing for: REINFORCEMENT BAR

COLUMN TYPE

Bar dia
(mm)

Stirrup (st2)

BAR SHAPE

LOCATION: BASEMENT FLOOR COLUMN

Bar length

1.15

No. of Bars No. of


on one col. Member

23

Total No.
of Bars

LENGTH
6

4.55

2.40

20

1.75

20

4.55

12

3.00

20

2.10

20

CONTRACTOR:

28

32

26.45

36.4

48

35

54.6

60

42

20

Total Length
Unit Wt./ml
Sub Total Wt.

24

20

Stirrup (st2)

20

12

16

Stirrup (st1)

16

20

4C53

14

20

Stirrup (st2)

12

16

Stirrup (st1)

10

23

4C48

2,333.45
0.222

0.395
921.71

0.617
-

0.888

1.210

1,101.10
1.580
1,739.74

2.470
-

3.550
-

4.790
-

6.260
-

CONSULTANT:

Das könnte Ihnen auch gefallen