Beruflich Dokumente
Kultur Dokumente
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
BAR SHAPE
4C18
Bar length
4.55
Total No.
of Bars
1.80
23
1.35
23
16
Stirrup (st1)
12
3.00
23
2.10
8
CONTRACTOR:
46
16
20
24
28
32
36.4
41.4
31.05
54.6
69
96.6
23
Stirrup (st2)
14
12
4.55
12
23
4C22
10
23
Stirrup (st2)
16
Stirrup (st1)
LENGTH
6
46
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C29
BAR SHAPE
Bar length
4.55
Total No.
of Bars
2.10
23
1.20
23
4.55
2.40
20
1.75
20
4.55
12
3.00
CONTRACTOR:
20
24
28
32
36.4
48.3
27.6
36.4
48
35
54.6
60
12
16
Stirrup (st1)
20
20
4C40
16
20
Stirrup (st2)
14
16
Stirrup (st1)
12
23
4C35
10
23
Stirrup (st2)
16
Stirrup (st1)
LENGTH
6
20
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
Stirrup (st2)
BAR SHAPE
Bar length
2.10
20
Total No.
of Bars
4.55
2.40
20
1.75
8
CONTRACTOR:
20
12
14
16
20
24
28
32
42
36.4
48
35
20
Stirrup (st2)
10
16
Stirrup (st1)
20
4C46
LENGTH
6
20
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C51
BAR SHAPE
Bar length
4.55
Total No.
of Bars
2.40
20
1.75
20
4.55
2.05
23
1.15
23
4.55
2.05
23
1.15
8
CONTRACTOR:
23
28
32
36.4
48
35
36.4
47.15
26.45
36.4
47.15
26.45
23
Stirrup (st2)
24
16
Stirrup (st1)
20
23
4C62
16
23
Stirrup (st2)
14
16
Stirrup (st1)
12
20
4C57
10
20
Stirrup (st2)
16
Stirrup (st1)
LENGTH
6
23
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C67
BAR SHAPE
Bar length
4.55
Total No.
of Bars
2.40
20
1.75
20
4.55
2.40
20
1.75
20
4.55
2.40
CONTRACTOR:
20
24
28
32
36.4
48
35
36.4
48
35
36.4
48
16
Stirrup (st1)
20
20
4C20
16
20
Stirrup (st2)
14
16
Stirrup (st1)
12
20
4C19
10
20
Stirrup (st2)
16
Stirrup (st1)
LENGTH
6
20
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
Stirrup (st2)
BAR SHAPE
Bar length
1.75
20
Total No.
of Bars
4.55
2.05
23
1.15
CONTRACTOR:
23
12
14
16
20
24
28
32
35
36.4
47.15
26.45
23
Stirrup (st2)
10
16
Stirrup (st1)
20
4C30
LENGTH
6
23
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C36
BAR SHAPE
Bar length
4.55
12
Total No.
of Bars
3.00
20
2.10
20
4.55
2.40
20
1.75
20
4.55
2.40
20
1.75
CONTRACTOR:
20
28
32
54.6
60
42
36.4
48
35
36.4
48
35
20
Stirrup (st2)
24
16
Stirrup (st1)
20
20
4C47
16
20
Stirrup (st2)
14
16
Stirrup (st1)
12
20
4C41
10
20
Stirrup (st2)
12
16
Stirrup (st1)
LENGTH
6
20
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C52
BAR SHAPE
Bar length
4.55
12
Total No.
of Bars
3.00
20
2.10
20
4.55
2.05
23
1.15
23
4.55
1.75
23
0.55
CONTRACTOR:
23
28
32
54.6
60
42
36.4
47.15
26.45
27.3
40.25
12.65
23
Stirrup (st2)
24
16
Stirrup (st1)
20
23
4C63
16
23
Stirrup (st2)
14
16
Stirrup (st1)
12
20
4C58
10
20
Stirrup (st2)
12
16
Stirrup (st1)
LENGTH
6
23
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C68
BAR SHAPE
Bar length
4.55
Total No.
of Bars
2.40
20
1.75
20
4.55
2.40
20
1.75
20
4.55
12
3.00
20
2.10
8
CONTRACTOR:
20
28
32
36.4
48
35
36.4
48
35
54.6
60
42
20
Stirrup (st2)
24
12
16
Stirrup (st1)
20
20
4C24
16
20
Stirrup (st2)
14
16
Stirrup (st1)
12
20
4C20
10
20
Stirrup (st2)
16
Stirrup (st1)
LENGTH
6
20
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
4C31
BAR SHAPE
Bar length
4.55
Total No.
of Bars
2.05
23
1.15
23
4.55
12
3.00
20
2.10
20
4.55
2.05
8
CONTRACTOR:
23
24
28
32
36.4
47.15
26.45
54.6
60
42
36.4
47.15
16
Stirrup (st1)
20
20
4C42
16
20
Stirrup (st2)
14
12
16
Stirrup (st1)
12
23
4C37
10
23
Stirrup (st2)
16
Stirrup (st1)
LENGTH
6
23
CONSULTANT:
103
Shop Drawings
ITP/SD/.
Client : MCIT
Consultant: _____________________________
ContraCtor: FLINTSTONE ENGINEERING
COLUMN TYPE
Bar dia
(mm)
Stirrup (st2)
BAR SHAPE
Bar length
1.15
23
Total No.
of Bars
LENGTH
6
4.55
2.40
20
1.75
20
4.55
12
3.00
20
2.10
20
CONTRACTOR:
28
32
26.45
36.4
48
35
54.6
60
42
20
Total Length
Unit Wt./ml
Sub Total Wt.
24
20
Stirrup (st2)
20
12
16
Stirrup (st1)
16
20
4C53
14
20
Stirrup (st2)
12
16
Stirrup (st1)
10
23
4C48
2,333.45
0.222
0.395
921.71
0.617
-
0.888
1.210
1,101.10
1.580
1,739.74
2.470
-
3.550
-
4.790
-
6.260
-
CONSULTANT: