Sie sind auf Seite 1von 8

Project: 131-13025-00

STEEL NOTES
1. STRUCTURAL STEEL SHALL CONFORM TO CAN/CSA-G40.20/G40.21 LATEST EDITION. 'W' SHAPES, PL'S : Fy=350 MPa ; TUBES Fy=350 MPa, CLASS C ; ANGLES, CHANNELS, 'I' SHAPES : Fy=300 MPa ; BOLTS : A325. ALL STRUCTURAL STEEL WORK TO BE CARRIED OUT IN ACCORDANCE WITH CAN/CSA-S16 LATEST EDITION. SHOP PAINT: ONE COAT PRIMER CONFORMING TO CPMA 1-73A, GREY COLOUR.

02/05/13 Project North:

S0
Seal:
L IC E N SE D

GENERAL NOTES
1. CONTRACTOR SHALL VERIFY, ON SITE AND WITH ARCHITECTURAL DRAWINGS, ALL DIMENSIONS & ELEVATIONS AND SHALL BE RESPONSIBLE FOR THESE. DO NOT SCALE DRAWINGS. PARTICULAR ATTENTION SHALL BE TAKEN WHERE THERE ARE STEPS AND OFFSETS OF THE FOUNDATION WALLS. PRIOR THE START OF THE PROJECT, CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AND SITE ACCESS. REPORT ANY DISCREPANCIES AND DAMAGES TO ENGINEER PRIOR TO PROCEEDING WITH WORK. WAIT FOR INSTRUCTIONS. CONTRACTOR SHALL COORDINATE AND REFER TO ARCHITECTURAL AND MECHANICAL & ELECTRICAL DRAWINGS FOR ALL OTHER DETAILS NECESSARY. COORDINATE ALL WORK WITH THE CLIENT AND USERS AT ALL TIMES. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THAT SAFETY IS MAINTAINED AT ALL TIMES. CONTRACTOR IS RESPONSIBLE TO DISPOSE OF ALL WASTE. CONTRACTOR SHALL KEEP WORK AREAS CLEAN AND WITHOUT OBSTRUCTIONS AT ALL TIMES. CONTRACTOR SHALL PROVIDE SECURE WORK AND STORAGE AREAS DURING AND UNTIL WORK COMPLETION. HEALTH AND SAFETY RULES FOR CONSTRUCTION SITES AND OTHER APPLICABLE LAWS SHALL BE RESPECTED AT ALL TIMES. PARTICULAR ATTENTION IS TO BE TAKEN IN REGARDS TO EXISTING CONDUITS AND EQUIPMENT IN AND AROUND WORK ZONE. CONTRACTOR IS TO PROVIDE ALL NECESSARY TEMPORARY SUPPORTS TO REALIZE WORKS. SOIL CAPACITY USED : ALL FOUNDATIONS TO BE PLACED ON UNDISTURBED STIFF SILTY CLAY WITH A ULS VALUE OF 175kPa AND SLS OF 100kPa. REFER TO GEOTECHNICAL REPORT ISSUED BY PATERSON GROUP. REFERENCE PG2683-1, DATED ON NOVEMBER 27 2012. DESIGN TO AND CONSTRUCTION TO 2006 O.B.C. UNDERSIDE OF ALL PERIMETER FOOTINGS SHALL REST AT LEAST 5'-0" MIN. (U.N.O.) BELOW FINISHED EXTERIOR GRADE. CONSULT SOILS ENGINEER FOR INSULATION REQUIREMENTS WHERE COVER CANNOT BE ATTAINED. GRANULAR FILL BELOW SLABS ON GRADE : REFER TO GEOTECNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION ALL MATERIAL USED FOR BACKFILL OF THE INTERIOR AND EXTERIOR OF FOUNDATION WALLS SHALL BE A COMPACTED GRANULAR FILL. SEE GEOTECNICAL ENGINEER. ALL STRUCTURAL ELEMENTS AND SOIL SHALL BE PROTECTED AGAINST FREEZING AT ALL TIMES. REFER TO ARCHITECTURAL SPECIFICATIONS FOR WATERPROOFING OF FOUNDATION WALLS. 15. 17. WHERE THERE IS PLUMBING / RAIN WATER LEADER, THE LEVEL OF THE FOOTINGS SHALL BE PLACED LOW ENOUGH SO AS NOT TO INTERFERE WITH THE PLUMBING. PROVIDE TRENCHES FOR MEC.-ELEC. SERVICES, AS REQUIRED. REFER TO MEC.-ELEC. DRAWINGS FOR LOCATIONS. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING OF NEW AND EXISTING STRUCTURES AND SOILS STABILITY (AT ALL TIMES) DURING CONSTRUCTION. DETAILS OF SHORING SHALL BE STAMPED BY A P.E.O. AND SUBMITTED FOR REVIEW. THE CONTRACTOR SHALL NOT BACKFILL THE FOUNDATION WALLS BEFORE ALL THE ELEMENTS WHICH ENSURE THEIR STABILITY ARE IN PLACE. GUARDS & RAILINGS, CURTAIN WALLS AND STEEL STUDS SHALL CONFORM TO O.B.C. LATEST EDITION. CONTRACTOR SHALL PROVIDE ENGINEERING DRAWINGS PREPARED BY A P.E.O. . 14. 13. 9. 2.

O FES SIONA L PR

G IN EN
EE R
R. G. GILLARD

3.

2.

4.

LEGEND: : INDICATES JOISTS TJ OR TJ M.C. : INDICATES TIE JOIST : INDICATES MOMENT CONNECTION

PROJECT NORTH

VI

NC

OF

ON

TA

3.

5.

4.

USE C6x8.2 FRAMES + CLOSURE 'L' FOR OPENINGS, SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR QUANTITY, DIMENSIONS AND LOCATIONS (OPENINGS ARE PARTIALLY SHOWN ON STRUCTURAL DWGS). STEEL DECK FIXATION: - SEE ROOF DECK LAYOUT/LEGEND ON DRAWING S3 PROVIDE SPLICE PLATES AT CHANGE OF DIRECTION IN DECKING SCREWED @ 300c/c EACH SIDE. THE STEEL MANUFACTURER WILL BE RESPONSIBLE TO CHECK AND CONFIRM ALL DIMENSIONS AND ELEVATIONS WITH THE ARCH. DWGS. ALL INCONSISTENCIES WILL HAVE TO BE TRANSMITTED TO THE ENGINEER FOR CHECKING. WAIT FOR INSTRUCTION BEFORE PRODUCTION. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STEEL STRUCTURE UNTIL PERMANENT SFRS IS COMPLETE. JOISTS BEING SUPPORTED ON THE SAME BEAM (FACE TO FACE), SHALL BE STAGGERED IF NECESSARY, TO PROVIDE THE MINIMAL SUPPORT LENGTH SPECIFIED BY THE JOISTS MANUFACTURER. REFER TO MECHANICAL-ELECTRICAL AND ARCHITECTURAL DRAWINGS FOR LOCATION, QUANTITY AND WEIGHT OF MECHANICAL UNITS. STEEL MANUFACTURER SHALL BE RESPONSIBLE TO CALCULATE ALL ROOF SLOPES. CALCULATE AND PROVIDE EACH BEAM'S ELEVATION WITH SHOP DRAWINGS FOR CONSULTANTS REVIEW. MASONRY SUPPORT PROVIDE 2"x12"x2"x1/8"mm @16"o/c VERT. ANCHOR PLATES WELDED TO COLUMNS WHERE MASONRY WALLS BUTT AGAINST THESE. PROVIDE BRACKETS FOR MASONRY WALL LATERAL SUPPORT, REFER TO TYPICAL DETAILS. PROVIDE WELDED DOWELS ON STEEL STRUCTURE FOR MASONRY WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR QUANTITY AND LOCATION. PROVIDE ADDITIONAL REINFORCING (AS REQUIRED) TO STEEL STRUCTURE AT ROOF ANCHORS LOCATION, REFER TO ARCHITECTURAL DRAWINGS FOR QUANTITY AND LOCATION. CONTRACTOR SHALL PROVIDE ENGINEERING DRAWINGS PREPARED BY A P.E.O. . ALL SHELF ANGLES AND HANGERS SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH CAN/CSA-G164 LATEST EDITION. WELDING ALL WELDING WORKS SHALL BE CONFORM TO CAN/CSA-16.1 LATEST EDITION. WELDERS SHALL BE CONFORM TO W47.1 AND W59 LATEST EDITION. CONTRACTOR AND WELDERS SHALL BE MEMBER OF THE CANADIAN WELDING BUREAU (C.W.B.). GALVANIZATION GALVANIZATION SHALL BE HOT DIPPED GALVANIZED, IN CONFORMITY WITH 2 CSA-G164 STANDARD. MINIMUM WEIGHT OF COAT SHALL BE 600 g/m . TOUCH-UP SHALL BE EXECUTED WITH "GALVANO SPRAY" BY "METAFLUX". OR APPROVED QUIVALENT.

STRUCTURAL DRAWING LIST SHEET NUMBER S0 S0.1 S1 S2 S3


S4 S5 S6
5.

6.

SHEET NAME GENERAL NOTES TYPICAL DETAILS FOUNDATION PLAN ROOF PLAN BUILDING ELEVATIONS & ROOF DECK LAYOUT BUILDING ELEVATIONS & PARAPET FRAMING PLAN FOUNDATION SECTION DETAILS STEEL SECTION DETAILS

7.

6. 7.

8.

8.

9. 10.

10.

11.

12. 11. 12.

DESIGN CRITERIA LATERAL LOADS


1. SEISMIC: MAIN BUILDING: - SEISMIC FORCE RESISTING SYSTEM (SFRS) SFRS: SYSTEM & CONNECTIONS: (2006 OBC CLAUSE 4.1.8.9/4.1.8.10) LATERAL LOAD RESISTING SYSTEM: CONVENTIONAL CONSTRUCTION (STEEL BRACED FRAMES) Rd = 1.5 Ro = 1.3 CSA STANDARD: CAN/CSA-S16-01 APPLICABLE CLAUSE(S): 27.10 SFRS: DIAPHRAGMS & CONNECTIONS: (2006 OBC CLAUSE 4.1.8.15) CSA STANDARD: CAN/CSA-S16-01 SFRS: SYSTEM FOUNDATIONS: (2006 OBC CLAUSE 4.1.8.16) CSA STANDARD: CAN/CSA A23.3-04 APPLICABLE CLAUSE(S): 15.2 TO 15.9 FOR ANCHORED FOOTINGS FOR UNANCHORED FOOTINGS CONFIRMATION: FOUNDATIONS HAVE BEEN DESIGNED TO RESIST THE LATERAL LOAD CAPACITY OF SFRS, INCLUDING ALL APPLICABLE AMPLIFICATION FACTORS. - IMPORTANCE FACTOR : (2006 OBC CLAUSE 4.1.8.5) - PERIOD DATA : STATIC PERIOD: (2006 OBC CLAUSE 4.1.8.11(3)) STEEL MOMENT FRAME: T ( a)STATIC T ( a)MAX = 0.085 (hn) 3/4 = 0.00 sec = 1.5 T ( a)STATIC = 0.00 sec = 0.075 (hn) 3/4 = 0.00 sec = 1.5 T ( a)STATIC = 0.00 sec = 0.1N = 0.00 sec = 1.5 T ( a)STATIC = 0.00 sec = 0.025hn = 0.155 sec = 2.0 T ( a)STATIC = 0.34 sec = 0.05(hn)
3 /4

13.

14.

CONCRETE MOMENT FRAME: T ( a)STATIC T ( a)MAX OTHER MOMENT FRAMES: T ( a)STATIC T ( a)MAX BRACED FRAMES: T ( a)STATIC T ( a)MAX SHEAR WALL AND OTHER T (a )STATIC STRUCTURES: T (a )MAX

15. 16.

= 0.00 sec

16.

= 2.0 T (a )STATIC = 0.00 sec

- HIGHER MODE FACTOR (2006 OBC CLAUSE 4.1.8.11(5)) Mv =1.0 J = 1.0

18.

- FUNDAMENTAL PERIOD BASED DSRAV: STATIC: S ( Ta )NS = 0.66 S (Ta )EW = 0.66 - STRUCTURAL CONFIGURATION (2006 OBC CLAUSE 4.1.8.11(9)) TORSIONAL SENSITIVITY ROOF; Bmax = 1.4 < 1.7

17.

1 No. Client:

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

19.

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

- IRREGULARITY REVIEW : (2006 OBC CLAUSE 4.1.8.6)

IE = 1.0
- PROJECT CITY: (OTTAWA, ONTARIO) - SITE CLASS : THE NOTED SITE CLASSIFICATION FOR SEISMIC SITE RESPONSE AND SHEAR WAVE VELOCITY PARAMETERS INDICATED ARE AS REPORTED IN THE GEOTECHNICAL REPORT ISSUED BY PATERSON GROUP. B C D E F (SITE SPECIFIC SPECTRUM: ) m/s NOT PERFORMED

1. VERTICAL STIFFNESS: 2. WEIGHT: 3. VERTICAL GEOMETRIC: 4. IN PLANE DISCONTINUITY: 5. OUT OF PLANE: 6. WEAK STOREY: 7. TORSIONAL: 8. NON-ORTHOGONAL: CONCLUSION: BUILDING IS DYNAMIC ANALYSIS: DYNAMIC PROCEDURE: METHOD:

YES YES YES YES YES YES YES YES

NO NO NO NO NO NO NO NO IRREGULAR NOT REQUIRED

CONCRETE NOTES
1. CONCRETE (@ 28 DAYS) : 25 MPa : SLAB-ON-GRADE (U.N.O.) 25 MPa : PERIMETER PAD & STRIP FTG. (U.N.O.) 25 MPa : PIERS (U.N.O.) 25 MPa : INTERIOR FOOTING (U.N.O.) 25 MPa c/w AIR : FDN WALLS AIR = ENTRAINED AIR BETWEEN 5% AND 7% ALL CONCRETE WORKS SHALL CONFORM TO CAN/CSA-A23 LATEST EDITION. REINFORCING STEEL : CAN/CSA-G30.18 LATEST EDITION Fy = 400 MPa WIRE MESH: CSA G30.5 LATEST EDITION USE CORNER BARS IN FOUNDATION WALLS ALL SLABS ON GRADE SHALL HAVE A MONOLITHIC FINISH UNLESS NOTED OTHERWISE, SEE ARCH. 6. 5. CONCRETE COVER TO REINFORCING : - FOOTINGS - FOUNDATION WALLS - PIERS : 3" : 1 1/2" : 1 1/2" 7.

MASONRY NOTES
1. 2. BLOCK STRENGTH: USE H/15/A/M UNITS CONFORMING TO CSA A165 LATEST EDITION. GROUT: USE 15 MPa MIX TO GROUT IN REINFORCED BLOCK CORES. USE 10mm AGGREGATE. MORTAR: USE TYPE 'S' MORTAR HORIZONTAL REINFORCEMENT: USE HOT DIP GALVANIZED TRUSS TYPE REINFORCING, LAP 350mm. VERTICAL REINFORCEMENT: SEE SCHEDULE. USE 36 dia. SPLICE LENGTH. PLACE ADDITIONAL 2-20M VERTICAL BARS AT ALL CORNERS AND ON EACH SIDE OF ALL OPENINGS. ALL REINFORCED CORES SHALL BE COMPLETELY FILLED WITH GROUT (SEE NOTE 2). GROUT THE CORES OF ALL BLOCKS LOCATED BELOW BEARING PLATES FOR TWO BLOCKS HIGH AND TWO WIDE. EXCEPT WHERE THERE IS A CONTINUOUS LINTEL. ALL MASONRY WORK SHALL CONFORM TO LATEST EDITION OF THE O.B.C. AND S304, A370 & A371 LATEST EDITION. COORDINATE REINFORCING STEEL IN BLOCK WALLS WITH MECHANICAL AND ELECTRICAL CONDUITS/SERVICES. CONDUITS/SERVICES SHALL NOT BE LOCATED WITHIN REINFORCED CORES. ALL MASONRY WORK SHALL BE LATERALLY SUPPORTED AND TIED TO THE STRUCTURE ABOVE, SEE TYPICAL DETAILS ON DRAWING ST-001. REFER TO STEEL STRUCTURE DRAWINGS & PILASTER SCHEDULE FOR ANCHOR PLATE LOCATIONS. CONTRACTOR SHALL COORDINATE AND REFER TO ARCHITECTURAL AND MECHANICAL-ELECTRICAL DRAWINGS FOR ALL OTHER DETAILS NECESSARY. PRIOR TO CONSTRUCTION, PREPARE AND SUBMIT SHOP DRAWINGS FOR REINFORCEMENT IN MASONRY WALLS & LINTELS. INDICATE ALL BAR DIAMETERS, LENGTH, LOCATIONS, DOWELS, CORNER DETAILS, ANCHOR PLATES, ETC. .
300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

REGULAR REQUIRED

HORIZONTAL SHEAR WAVE VELOCITY: - PGA: 0.42 - RESPONSE SPECTRUM DATA :

MODAL RESPONSE SPECTRUM NUMERICAL INTEGRATION TIME HISTORY N/A

2. 3.

3.

4. 5.

- 5% DAMPED SPECTRAL RESPONSE ACCELERATION VALUES: (2006 OBC SUPPLEMENTARY STANDARD SB-1) Sa(0) Sa(0.2) Sa(0.5) Sa(1.0) Sa(2.0) Sa(4.0) = 0.660 = 0.660 = 0.320 = 0.130 = 0.044 = 0.022

- ANALYSIS METHOD: EQUIV. STATIC DYNAMIC - TORSIONAL ECCENTRICITY: 0.10 Dnx (4.1.8.11(10a), B < 1.7 EQUIV. STATIC FORCE PROCEDURE 0.10 Dnx (4.1.8.12(4a), B >1.7 (DYNAMIC ANALYSIS) 0.05 Dnx (4.1.8.12(4b), B < 1.7 (DYNAMIC ANALYSIS) - STATIC BASE SHEARS/MOMENTS (2006 OBC CLAUSE 4.1.8.11) W = 897 kips (IN EACH DIRECTION) V MIN = S(2.0)MvI E W/(RdRo) = 0.0226W V = S(Ta)M VI EW/(RdRo) = 0.338W V MAX = 2 S(0.2) IE W/(RdRo) = 0.226W = 202kips-GOVERNS 3 Mbase = 4121 ft-kips 2. WIND: (CORNWALL, ONTARIO) P = Iw q(1:50) Ce Cp Cg where; q 1:50 = 0.41 kPa / q 1:10 = 0.3 kPa Iw = 1.0 Ce: (ROUGH TERRAIN) Ce=0.7 ~ 0.97 Cp Cg = 1.30 (avg) / 1.95 (max) Cp Cg = 1.30 (avg) / 1.95 (max) (E-W) 35 kips 404 ft-kips Vbase Mbase 20 kips 228 ft-kips

Project Name:

575 INDUSTRIAL AVE. OTTAWA, ON.


OTTAWA TRAIN YARDS, EAST LANDS

4.

RI O

- DESIGN SPECTRAL RESPONSE ACCELERATION VALUES (DSRAV) : (2006 OBC CLAUSE 4.1.8.4) CLASS 'A': (Fa=0.768:Fv=0.5) CLASS 'B': (Fa=0.868:Fv=0.64) S(0) S(0.2) S(0.5) S(1.0) S(2.0) S(4.0) = 0.504 = 0.504 = 0.160 = 0.065 = 0.022 = 0.011 S(0) S(0.2) S(0.5) S(1.0) S(2.0) S(4.0) = 0.570 = 0.570 = 0.202 = 0.082 = 0.028 = 0.014

6.

DESIGN & DETAILING CRITERIA FOR CONTRACTORS


REINFORCING STEEL CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL REINFORCING STEEL INCLUDING PLACEMENT OF REINFORCEMENT. INDICATED ON THE SHOP DRAWINGS SHALL BE BAR BENDING DETAILS, LISTS, QUANTITIES OF REINFORCEMENT, SIZES, SPACINGS, LOCATIONS OF REINFORCEMENT SPLICES (LAP OR MECHANICAL) WITH IDENTIFYING CODE MARKS TO PERMIT CORRECT PLACEMENT OF REINFORCEMENT WITHOUT REFERENCE TO THE STRUCTURAL DRAWINGS. PREPARE SHOP DRAWINGS IN ACCORDANCE WITH REINFORCING STEEL MANUAL OF STANDARD PRACTICE. MISCELLANEOUS METALS MISCELLANEOUS METALS ARE TO BE DESIGNED AND DETAILED BY THE MISC. METALS SUPPLIER. SHOP DRAWINGS ARE TO BE SUBMITTED TO GENIVAR FOR REVIEW. SHOP DRAWINGS ARE TO BE STAMPED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROVINCE OF ONTARIO. ALL MISC. METALS AND STEEL STAIRS ARE TO BE FIELD REVIEWED BY THE DESIGN ENGINEER. RAILINGS AND GUARDS ALL RAILINGS AND GUARDS ARE TO BE DESIGNED AND DETAILED BY THE MISC. METALS SUPPLIER IN ACCORDANCE WITH OBC 4.1.5.15 AND 3.4.6.4.(9). SHOP DRAWINGS ARE TO BE SUBMITTED TO GENIVAR FOR REVIEW. SHOP DRAWINGS ARE TO BE STAMPED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROVINCE OF ONTARIO. ALL RAILINGS AND GUARDS ARE TO BE FIELD REVIEWED BY THE DESIGN ENGINEER. STRUCTURAL STEEL CONNECTIONS STRUCTURAL STEEL CONNECTIONS ARE TO BE DESIGNED AND DETAILED BY THE STRUCTURAL STEEL SUPPLIER. SHOP DRAWINGS ARE TO BE SUBMITTED TO GENIVAR FOR REVIEW. SHOP DRAWINGS ARE TO BE STAMPED AND SIGNED 'FOR CONNECTIONS ONLY' BY A PROFESSIONAL ENGINEER LICENSED IN THE PROVINCE OF ONTARIO.

OPENINGS IN FOUNDATION WALLS : USE 2-20M ALL AROUND OPENINGS AND EXTEND 600mm BEYOND OPENING + CORNER BARS, SEE TYPICAL DETAIL. SEE ARCH. AND MECH-ELEC. DRAWINGS FOR QUANTITIES AND LOCATIONS. FOR PITS NOT EXCEEDING 900x900mm USE 150mm WALLS AND 200mm RAFT REINFORCED WITH 10M @ 200c/c 2-DIRECTIONS CENTER, SEE TYPICAL DETAIL. SEE ARCH. & MECH. FOR QUANTITY AND LOCATION. CONTROL JOINTS IN SLAB ON GRADE : CONTROL JOINTS SHALL BE SAWCUT INTO PANELS WHICH DO NOT EXCEED 3.6m x 3.6m WITHIN 24 HOURS OF SLAB POUR. JOINTS SHALL BE 3/16" IN WIDTH BY 1" (MIN.) IN DEPTH c/w APPROVED JOINT FILLER. SEE SPECIFICATIONS. ALL EXPOSED CONCRETE CORNERS SHALL HAVE A 1" CHAMFER. ALL FORMWORK SHALL CONFORM TO CAN/CSA-A23.1/A23.2 LATEST EDITION, FURTHERMORE FORMWORK USED WHERE CONCRETE FINISH IS EXPOSED SHALL BE NEW. PROVIDE A DEPRESSION IN THE CONCRETE SLAB FOR FOOT GRILLS. REFER TO ARCHITECTURAL DWGS FOR LOCATIONS WHERE REQUIRED. PROVIDE 15M x 36" LG. @ 24" o/c DOWELS AT JUNCTION OF FOUNDATION AND MASONRY WALLS, SEE ARCHITECTURE FOR QUANTITY AND LOCATIONS. ALL MECHANICAL PADS AND BASES SHALL BE TIED TO CONCRETE SLABS (STRUCTURAL OR ON GRADE) WITH 10M x 300 LG. DOWELS @ 450c/c 2-DIRECTIONS (PROVIDE EPOXY ADHESIVE IF NON-MONOLITHIC) c/w W.W.M. 152x152-18.7/18.7 (IN SHEETS) CENTER TYP. SEE MECHANICAL FOR SIZES, LOCATIONS AND 100 QUANTITIES. 150 50

8. 9.

7.

10. 11. 12. 13.

CLASS 'C': (Fa=1.0:Fv=1.0) S(0) S(0.2) S(0.5) S(1.0) S(2.0) S(4.0) = 0.660 = 0.660 = 0.320 = 0.130 = 0.044 = 0.022

CLASS 'D': (Fa=1.136:Fv=1.37) S(0) S(0.2) S(0.5) S(1.0) S(2.0) S(4.0) = 0.750 = 0.750 = 0.438 = 0.178 = 0.060 = 0.030

8.

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

N-S E-W (N-S) Vbase Mbase

9. 10.

CLASS 'E': (Fa=1.208:Fv=2.07) S(0) S(0.2) S(0.5) S(1.0) S(2.0) S(4.0) = 0.797 = 0.797 = 0.662 = 0.269 = 0.091 = 0.046

11.

MASONRY BLOCK WALL REINFORCEMENT SIZE VERT. REINF. SEE S0.1 SEE S0.1 HORIZ. REINF. REFER TO DETAIL 'N' ON DRAWING S0.1

12.

architects inc.
www.farrow-dreessen.com

TYPICAL INTERIOR WALL 140mm 190mm

- STRUCTURAL SEPARATION : THE NEW & EXISTING STRUCTURAL HAVE BEEN SEPARATED IN ACCORDANCE WITH 4.1.8.14 (1) OF THE 2006 OBC. N/A - SYSTEM RESTRICTION VALUE :
IoFaSa(0.2)=0.66

SNOW LOADING
S = Is [Ss (Cb Cw Cs Ca) + Sr]

(OTTAWA, ONTARIO)

13.

Drawing:

1/2" = 1'-0"

GENERAL NOTES
NOTE: PADS SLAB REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL OPENINGS IN MASONRY WALLS AS WELL AS BEAM BEARING LOCATIONS, PROVIDE ADDITIONAL CONTINUOUS VERTICAL REINFORCEMENT EACH SIDE OF OPENING AND BELOW BEAM BEARING LOCATIONS, SEE LINTEL AND PILASTER SCHEDULES.

> 0.35

YES NO

where: Ss = 50 psf, Sr = 8.4 psf Is = 1.0 Cb = 0.8, Cw = 1.0, Cs = 1.0 Ca = 1.0 (EXCEPT FOR SNOW DRIFTING - SEE PLANS) Smax = 48 psf + DRIFTING (SEE PLANS)

Project: 131-13025-00 02/05/13

4/5/2013 9:41:34 AM

S0

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

PR

Project: 131-13025-00
STEEL : Fy = 400 MPa
4'-0" MIN.

APPROVED JOINT FILLER c/w REGLET COMPRESSION 300mm 450mm 600mm 750mm 900mm 1050mm APPROVED JOINT FILLER c/w REGLET

APPROVED MEMBRANE (300mm MIN.)

EXT GRADE ELEV VARIES, SEE ARCH'L

STEEL DECK. SEE PLANS HSS 4x4x 1/4" SHEAR TRANSFER ELEMENTS AT EACH EXTERIOR BEAM LINE SPECIFIED ON ROOF PLAN, SEE DRAWING 'S2' FOR LOCATIONS & QUANTITIES

02/05/13 Project North:

S0.1
Seal:
L IC E N SE D

BAR 10M
2'-0" MAX.

TENSION 450mm 700mm 1000mm 1500mm 1800mm 2100mm

O FES SIONA L PR

G IN EN

15M 20M 25M 2 1 30M 35M

BUILDING INTERIOR
COVER DEPTH

EE R

R. G. GILLARD

'T' INSULATION

SEE TABLE FOR REQ'TS

CONTROL JOINTS
(STANDARD WALLS)

SUPPORTING BEAMS. SEE PLANS FOR SIZES OWSJ, SEE PLANS FOR SIZE AND SPACING

PROJECT NORTH

VI

NC

OF

ON

TA

'L' INSULATION

MINIMUM REINFORCEMENT SPLICE


2
T MIN. T MIN.

APPROVED JOINT FILLER c/w REGLET

APPROVED MEMBRANE (300mm MIN.)

1 15M x 36"LG. @ 24" o/c AT BLOCK WALLS 2-15M CONT. CUT HORIZ. REINFORCEMENT EXCEPT 2-20M TOP & BOTTOM

TYPICAL SHEAR TRANSFER ELEMENT DETAIL FOR STEEL DECK


TYPICAL EXTERIOR FOOTING INSULATION DETAIL
APPROVED JOINT FILLER c/w REGLET CONFIRM WITH GEOTECHNICAL ENGINEER
TOP OF BLOCK TO BE LEFT CLEAR OF U/S OF STRUCTURE

STEP FOOTINGS

10"

12" MIN.

2'-2"

U
TOP OF BLOCK TO BE LEFT CLEAR OF U/S OF STRUCTURE

EXPANSION JOINTS
1 (STANDARD WALLS) 1

INSULATION DIMENSIONS COVER DEPTH (INCHES) L insulation (inches) T insulation (inches)


L38x38x5 BTWN OWSJ's @ 1200 o/c

FOOTING

24" MIN.

LESS THAN 24" 24" TO 30" 72" 48" 48" 36"

NOT RECOMMENDED 2" 2" 1 1/2" 1" NOT REQUIRED


L 50x75x6 x 150 LG CLIP ANGLES E.S. OF BLOCK @ EACH OWSJ LOCATION.

4" MIN.

2 1
12" MIN.

SEE ARCH'L FOR QUANTITY, DIMENSIONS AND LOCATIONS

MASONRY PILASTER SCHEDULE


(EACH SIDE ALL OPENINGS & @ ALL CORNERS)

30" TO 36" 36" TO 48"

SLAB THICKENING
(NON-LOAD BEARING MASONRY WALLS)

WALL SIZE

MARK MP1

PILASTER
2 CELLS c/w 1-20M IN EACH CELL, FULLY GROUTED

SCHEMATIC
OPENNG

48" TO 60" GREATER THAN 60"

L 50x75x6 x 150 LG CLIP ANGLES E.S. OF BLOCK @ EACH OWSJ LOCATION.

H
MAXIMUM SPACING OF SAW CUTS TO BE 3.6m o/c UNLESS NOTED.

ALL WALLS

NOTES:
1. CONSULT GEOTECHNICAL ENGINEER FOR THERMAL RESISTANCE VALUES OF ACCEPTABLE INSULATION TYPES. 2. INSULATION REQUIRED DOWN OUTSIDE FACE OF FOUNDATION WALL AND OUTWARD FROM WALL AS SHOWN. 3. ALL EXTERIOR FOOTINGS ARE TO FOLLOW THESE REQUIREMENTS UNLESS DIRECTED OTHERWISE BY GEOTECHNICAL ENGINEER.

WALL PERPENDICULAR TO OWSJ'S

WALL PARALLEL TO OWSJ'S

MECHANICAL SERVICES
(UNDER FOOTINGS)

GRID
SAW-CUT PROVIDE BOND BREAK AROUND COLUMNS, TYP.

MASONRY WALL REINFORCING SCHEDULE


WALL SIZE
90mm

HORIZONTAL REINF.
N/A STANDARD BLOCK-TRUSS (9GA.) @ 16" o/c HEAVY DUTY BLOCK-TRUSS (6GA.) @ 16" o/c HEAVY DUTY BLOCK-TRUSS (6GA.) @ 16" o/c

VERTICAL REINF.
N/A 1-15M @ 32" o/c + DWLS, SEE NOTES

4-15M
1'-6" 1'-6"
6"

LATERAL SUPPORT FOR NON-LOAD BEARING PARTITIONS @ OWSJ'S

GRID

140mm

MIN.

1 SAW-CUT
12"
MIN.

MIN.

24"

SAW-CUT AT COLUMNS

190mm

1-20M @ 32" o/c + DWLS, SEE NOTES 2-15M @ 32" o/c + DWLS, SEE NOTES
24"
MIN.

24"

BAR LENGTH
8'-0" OR LESS 8'-0" TO 12'-0" 12'-0" TO 16'-0" CHAIRS AT 4'-0" o/c. MAX.

NO. OF CHAIRS
3 4 5

SEE MECH.

12"
MIN.

240mm APPROVED JOINT FILLER SEE PLAN FOR SLAB THICKNESS & REIN'F (IF REQUIRED)
1/5 T OR 1" MIN.

NOTES:
1. PROVIDE DWLS. 36" LONG, SIZE & SPACING TO MATCH VERTICAL WALL REINFORCEMENT. 2. ADD HORIZONTAL BOND BEAM AT EACH FLOOR AND ROOF LEVEL. 3. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL OPENINGS IN MASONRY WALLS. ADDITIONAL BARS x 24" LG. TYP. EACH. CORNER
24"
MIN.

MECHANICAL SERVICES TRENCH


(UNDER FOOTINGS)

C
2-20M x 1350 LG.

TOP STEEL ; GALVANIZED OR PLASTIC COVERED CHAIRS MAIN REINFORCING MAIN REINFORCING OR 15M MIN. CHAIR BARS
1200mm MAX.

6" MIN.

COMPACTED GRANULAR FILL, REFER TO GEOTECHNICAL ENGINEER

MASONRY WALL REINFORCING SCHEDULE FOR SITES WITH SEISMIC HAZARD INDEX 0.35 < Ie x Fa x Sa (0.20) < 0.75
UNLESS NOTED OTHERWISE ON PLAN, ALL MASONRY WALLS SHALL BE REINFORCED AS FOLLOWS:

REINFORCING

CHAIR B: BOTTOM STEEL : PLASTIC BOLSTERS SLABS : BOLSTERS @ 48"c/c MAX. 2-DIR. BEAMS : BOLSTERS @ 36"c/c MAX.

6"-8" WALLS : 1-20M ON ONE FACE ALL AROUND OPENING U.N.O. 10" & + WALLS : 1-20M EACH FACE ALL AROUND OPENING U.N.O.

1 No. Client:

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

SAW-CUT DETAIL MECHANICAL SERVICES


(TROUGH CONTINUOUS STRIP FOOTINGS)

I
STOP HORIZONTAL BLOCK REINFORCEMENT 1" SHORT EACH SIDE OF CONTROL JOINT

N
HOLES IN FOUNDATION WALLS

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

D
ALTERNATE DIRECTION OF CORNER BARS

SEE PLAN FOR SLAB THICKNESS & REIN'F (IF REQUIRED)

24" OR LESS

COVER, FRAMES AND ANCHORS SEE MECH.-ARCH.

HORIZONTAL TRUSS TYPE REINFORCING TYP.

1"

LINE ONE SIDE OF CORE WITH CONSTRUCTION PAPER PRIOR TO FILLING CORE WITH CONCRETE TYP.

SEE PLAN FOR SLAB THICKNESS & REIN'F (IF REQUIRED)

SEE DETAIL #9 FOR SAW-CUT

C6x8.2
12" MIN.

1 2
6" 6"

10M @ 12" E.W.


36d LAP TYP. 36d LAP TYP.

C6x8.2

L4x4x 5/16 " x 6" LG. HANGER, TYP.

C6x8.2

SHALLOW SEE PLAN FOR SLAB THICKNESS & REIN'F (IF REQUIRED)
SEE MECH'L .

TYPICAL SINGLE LAYER REINFORCED WALL COVER, FRAMES AND ANCHORS SEE MECH.-ARCH.

FILL CORES EACH SIDE OF CONTROL JOINT FULL HEIGHT WITH CONCRETE, REINFORCE WITH 2-15M TYP.

APPROVED CAULKING TYP. EACH SIDE

SEE MECH'L .

C6x8.2

COMPACTED GRANULAR FILL, REFER TO GEOTECHNICAL ENGINEER

Project Name:

C6x8.2 COMPACTED GRANULAR FILL, REFER TO GEOTECHNICAL ENGINEER


3" CLEAR 8"

10M @ 12" E.W.

CONTROL JOINT - MASONRY WALLS


36d LAP TYP. 36d LAP TYP.

COVER, FRAMES AND ANCHORS SEE MECH.-ARCH. STEEL DECK


900x900 MAX.
300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

DEEP TYPICAL DOUBLE LAYER REINFORCED WALL

TRENCHES

PLAN VIEW SEE PLANS AND SECTIONS FOR SIZE & REIN'F OF WALLS 'MP1', SEE SCHEDULE 10M @ 200 o/c
SEE MECH.

150

10M @ 200 o/c

STEEL DECK

L4x4x 5/16" x 6" LG. HANGER, TYP.

TYP FDN WALL INTERSECTION REINF'G


OPENING UP TO 1200mm 1201-1500mm 1501-2100mm 2101-2400mm 2401-2700mm 2701-3610mm 3611-4500mm BRICK ANGLE SIZE L90x90x6 L90x90x8 L100x90x8 L125x90x8 L125x90x10
21/2"

CUT ROOF DECK @ OPENINGS & PROVIDE CONT, L1 1 2"x11 2"x1 8" PERIMETER ANGLE ALL AROUND

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

APPROVED JOINT FILLER c/w REGLET

APPROVED MEMBRANE (300mm MIN.)

SEE PLAN FOR CONC BLOCK SIZE & REFER TO MASONRY NOTES FOR REIN'F

150

10M @ 200 o/c

10M x600 @ 200 o/c

C6x8.2, TYP.

architects inc.
2"

L150x100x10 L175x100x12

ROOF JOIST
SEE
TABLE 12

ROOF JOIST SECTION VIEW

www.farrow-dreessen.com

Drawing:

1/2" = 1'-0"

LOOSE LINTEL SCHEDULE FOR BRICK

CONSTRUCTION JOINTS
(STANDARD WALLS)

TYP. CORNER - MASONRY WALLS

CATCH BASIN, SUMP PIT & OIL INTERCEPTOR

TYP. FRAMING DETAIL - ROOF DECK OPENING

X
02/05/13

TYPICAL DETAILS

Project: 131-13025-00

4/5/2013 9:41:35 AM

S0.1

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

8"

8"

PROVIDE CONTROL JOINTS WHERE CALLED FOR (SEE ARCHITECTURE), AT INTERSECTIONS OF BEARING & NON-LOAD BEARING WALLS AND AT EMBEDDED STEEL COLUMNS.

CONSTRUCTION JOINTS
(SLAB-ON-GRADE)

OPENING

575 INDUSTRIAL AVE. OTTAWA, ON.


OTTAWA TRAIN YARDS, EAST LANDS

CUT ROOF DECK @ OPENINGS & PROVIDE CONT, L1 1/2"x1 1/2"x 1/8" PERIMETER ANGLE ALL AROUND

300

RI O

CUT HORIZ. REINFORCEMENT EXCEPT 2-20M TOP & BOTTOM

PR

Project: 131-13025-00

1
12' - 4"

2
9' - 11 1/2"

3
17' - 1 7/8" SEE ARCH'L FDN-1 WF1

4
8' - 7 7/8" 1' - 4 3/4"

5
8' - 6"

6
8' - 6"

7
8' - 7 7/8" SEE ARCH'L

8
17' - 1 7/8" TYP. 1 FDN-1&3 S5

9
11' - 8 1/4"

10
8' - 6"

11
8' - 6"

12
11' - 8 1/4" SEE ARCH'L

13
16' - 10 3/8" 1' - 4 3/4"

14
8' - 6"

15
8' - 6" TYP. PIER @ FDN-3&4 FDN-3 WF3

16 17
4' - 2 1/4" 4 S5 12' - 8 1/8"

18

02/05/13 Project North:

S1
Seal:
L IC E N SE D

O FES SIONA L PR

G IN EN

FDN-3 WF3

FDN-3 WF3

FDN-3 WF3

FDN-1 WF1

FDN-1 WF1

FDN-1 WF1

FDN-1 WF1

FDN-3 WF3

FDN-3 WF3

EE R

R. G. GILLARD

A
12' - 2 7/8" FDN-2 WF2

1' - 8 1/2"

1' - 8 1/2"

BP4 C3 F4 P2 BP1 C1 F4 P2 BP1 C1 3 3/4" 1' - 8 1/2" F5 P2 BP3 C1 F5 P3 BP3 C1

B
12' - 2 7/8" FDN-2 WF2

C
12' - 2 7/8"

F3 P1 BP2 C2 R.W.L LOC.

F3 P1 BP2 C2 R.W.L LOC.

F3 P1 BP2 C2

6 S5 TYP. @ INT. PIER

F3 P1 BP2 C2

FDN-2 WF2

D
12' - 2 7/8"

F4 P2 BP1 C1 FDN-2 WF4

TYP 4" SLAB-ON-GRADE U.N.O. SEE FOUNDATION NOTES FOR ELEVATION, REIN'F, SAW-CUTS & SLOPES (IF REQUIRED) CONSULT SOILS ENGINEER FOR COMPOSITION AND COMPACTION OF SOILS SUPPORTING SLAB-ON-GRADE F5 P2 BP3 C1

F4 P2 BP1 C1 WF4 FDN-4

BF1

WF4 FDN-4

WF4 FDN-4

WF4 FDN-4

F1 P2 BP2 C2

3 3/4"

3 3/4"

BP4 C3

BP4 C3

F2 P2 BP2 C2

F2 P2 BP2 C2

BP4 C3

BP4 C3

F2 P2 BP2 C2

F2 P2 BP1 C1

F2 P2 BP1 C1

F2 P2 BP1 C1

BP4 C3

F2 P2 BP1 C1

F2 P2 BP1 C1

BP4 C3

F2 P2 BP1 C1

PROJECT NORTH

VI

NC

OF

ON

TA

1' - 4 3/4"

E
11' - 1" FDN-2 WF2

F3 P1 BP2 C2

F3 P1 BP2 C2 SEE DETAIL I ON DRAWING S0.1 FOR SAW-CUT AROUND COLUMNS, TYP.

F3 P1 BP2 C2

F3 P1 BP2 C2

F5 P3 BP3 C1

F
11' - 0 7/8" 1' - 4 3/4"

3 S5 FDN-2 WF2 TYP. PIER @ FDN-1&2

F4 P2 BP1 C1

SEE DETAIL I ON DRAWING S0.1 FOR SAW-CUT SPACING & DEPTH

F4 P2 BP1 C1 WF2 FDN-2

FDN-3 WF3

FDN-3 WF3

G
3 3/4" 1' - 8 1/2" 13' - 4 1/2" FDN-3 WF3 F2 P2 BP1 C1 C3 BP4 F2 P2 BP1 C1 13' - 4 1/2" 1' - 4 3/4" FDN-3 WF3 3 3/4" 1' - 8 1/2" C3 BP4 1' - 8 1/2" C3 BP4 3 3/4" 1' - 8 1/2" F2 P2 BP1 C1 F2 P2 BP1 C1

F3 P3 BP1 C1 R.W.L LOC.

F3 P1 BP2 C2

F3 P1 BP2 C2 R.W.L LOC.

F3 P1 BP2 C2

F3 P1 BP2 C2

TYP. FDN-2&4 2 S5

SEE ARCH'L

WF2 FDN-2

BF2

F2 P2 BP1 C1

1 No. Client:
WF1 FDN-1

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

CONTROLEX CORP.
SEE ARCH'L

TEL: 613-723-7490 FAX: 613-723-7483

F2 P2 BP1 C1 3 3/4" TYP. U.N.O. 1' - 2 1/2" TYP. U.N.O. TYPICAL CHECK IN FOUNDATION AT ALL DOOR LOC. SEE ARCH'L FOR DOOR SIZE & LOCATION F2 P2 BP1 C1 F2 P2 BP1 C3 C1 BP4 F2 P2 BP1 C1 F2 P2 BP1 C3 C1 BP4 WF1 FDN-1 190mm CONC. BLOCK WALL c/w SLAB THICKENING BELOW, SEE GENERAL NOTES & TYPICAL DETAILS FOR REIN'F F2 P2 BP1 C1 F5 P3 BP3 C1 F2 P2 BP1 C1 SEE ARCH'L

C3 BP4

F5 P3 BP3 C1

F1 P2 BP1 C1

F5 P3 BP3 C1

C3 BP4

C3 BP4

F2 P2 BP1 C1

C3 BP4

C3 BP4

C3 BP4

C3 BP4

C3 BP4

C3 BP4

C3 BP4

F5 P3 BP3 C1

Project Name:

10 3/4" TYP. U.N.O.

1' - 4 3/4"

F2 P2 BP1 C1

WF3 FDN-3

WF3 FDN-3

WF1 FDN-1 BF4 SEE ARCH'L

WF1 FDN-1

WF1 FDN-1 5 S5 TYP. @ DOOR

WF1 FDN-1

WF3 FDN-3 SEE ARCH'L

WF3 FDN-3

WF3 FDN-3

WF1 FDN-1

WF1 FDN-1

WF1 FDN-1 BF3

WF1 FDN-1

575 INDUSTRIAL AVE. OTTAWA, ON.


OTTAWA TRAIN YARDS, EAST LANDS

FOUNDATION PLAN 1/8" = 1'-0"

MARK FDN-1

FDN-2

FDN-3

FDN-4

1' - 0"

EQ.

1' - 6"

FOUNDATION WALL SCHEDULE WIDTH REIN'F 14 1/2" WIDE 2-20M T&B CONT. 15M @ 16" o/c. E.W. E.F. +DWLS TO FTG. 14 1/2" WIDE 3-25M T&B CONT. 15M @ 16" o/c. E.W. E.F. +DWLS TO FTG. 20 1/2" WIDE 2-20M T&B CONT. 15M @ 16" o/c. E.W. E.F. +DWLS TO FTG. 20 1/2" WIDE 3-25M T&B CONT. 15M @ 16" o/c. E.W. E.F. +DWLS TO FTG.

PIER SCHEDULE MARK DESCRIPTION REIN'F TIES P1 22" ROUND 8-15M 10M @ 12" o/c. + 3-10M @ 3" o/c. TOP P2 21" x 21" 8-15M 3-10M @ 12" o/c. + 3 ADD'L 3-10M @ 3" o/c. TOP P3 21" x 21" 8-20M 3-10M @ 12" o/c. + 3 ADD'L 3-10M @ 3" o/c. TOP

MARK BP1 BP2 BP3 BP4

BASEPLATE SCHEDULE DESCRIPTION ANCHORS ELEVATION 12" x 12" x 3/4" 4 - AB1 u/s B.PL. EL -10" TYP. U.N.O. 14" x 14" x 3/4" 4 - AB1 u/s B.PL. EL -10" TYP. U.N.O. 14" x 14" x 1" 4 - AB2 u/s B.PL. EL -10" TYP. U.N.O. 8" x 5" x 3/4" 1 - AB1 u/s B.PL. EL 2" TYP. U.N.O.

GRID GRID GRID

GRID
EQ. EQ.

TYPICAL AB1 3/4" (A307) ALL TREADED ANCHOR BOLT c/w NUT & WASHER (PROVIDE 12" MIN. EMBEDMENT)

TYPICAL AB2 1 1/8" (B7) ALL TREADED ANCHOR BOLT + 2 1/4" x 2 1/4" x 3/4" PL. c/w NUT & WASHER (PROVIDE 18" MIN. EMBEDMENT)

MARK F1 F2 F3 F4 F5 WF1 WF2 WF3 WF4

FOOTING SCHEDULE SIZE DESCRIPTION 3'-0" x 3'-0" x 10" DP. 4-15M B.E.W. 3'-10" x 3'-10" x 10" DP. 5-15M B.E.W. 6'-6" x 6'-6" x 12" DP. 7-15M B.E.W. 4'-0" x 4'-0" x 10" DP. 5-15M T&B E.W. 10'-0" x 10'-0" x 18" DP. 13-20M T&B E.W. 24" WIDE x 10" DP. 3-15M BOTTOM CONT. 24" WIDE x 10" DP. 3-25M BOTTOM CONT. 36" WIDE x 10" DP. 4-15M BOTTOM CONT. 36" WIDE x 10" DP. 4-25M BOTTOM CONT.

FOUNDATION NOTES: 1. GENERAL: - SEE DRAWING 'S0' & 'S0.1' FOR GENERAL NOTES AND TYPICAL DETAILS. - REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND ELEVATIONS. 2. SLAB-ON-GRADE: - T.O. SLAB-ON-GRADE @ EL. 0'-0", TYP. U.N.O. - 4" NON-REINFORCED CONCRETE SLAB-ON-GRADE TYP. U.N.O. - CONSULT SOILS ENGINEER FOR COMPOSITION AND COMPACTION OF SOILS SUPPORTING SLABON-GRADE. - SAW-CUT NEW SLAB-ON-GRADE AT SPACING NOT TO EXCEED 3.6m IN EACH DIRECTION (13.0 sq.m. MAX PER PANEL). SEE DRAWING 'S0.1'. - PROVIDE SLOPES TO FLOOR DRAINS IN CONCRETE SLABS WHERE & IF REQUIRED, REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 3. FOOTINGS: - PROVIDE DOWELS IN FOOTINGS FOR PIERS, & FDN WALL ABOVE. MATCH NUMBER, SIZE & SPACING IN PIER & FDN WALL ABOVE - SEE DRAWING 'S0' FOR u/s OF FOOTINGS EL. AND SOILS CAPACITY REQUIREMENTS - ALL FOOTINGS TO BE CENTRED ON GRIDLINES U.N.O. 4. FOUNDATION WALLS: - T.O. FOUNDATION WALL @ EL. 0'-0", TYP. U.N.O. - FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH CLAUSE 4.1.8.16 OF THE 2006 OBC. 4. PIERS: - T.O. PIERS @ EL. -12" TYP. U.N.O. - T.O. INTERIOR PIERS @ EL. -18" AT R.W.L. - ALL PIERS TO BE CENTRED ON GRIDLINE U.N.O.

300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

architects inc.
www.farrow-dreessen.com

2
4/5/2013 9:41:38 AM

PIER P1 DETAIL 1/2" = 1'-0"

PIER P2-P3 DETAIL 1/2" = 1'-0"

TYPICAL ANCHOR BOLTS DETAIL 3/4" = 1'-0"

COLUMN/STUB COLUMN SCHEDULE MARK DESCRIPTION C1 HSS 6 x 6 x 1/4" C2 HSS 7 x 7 x 1/4" C3 HSS 4 x 4 x 1/4" SC1 HSS 6 x 6 x 1/4"

Drawing:

As indicated

EQ.

FOUNDATION PLAN

Project: 131-13025-00 02/05/13

S1

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

SEE ARCH'L

RI O

PR

Project: 131-13025-00

1
12' - 4"

2
9' - 11 1/2"

3
17' - 1 7/8" T.O.S. H.P.T.

4
8' - 7 7/8"

5
8' - 6"

6
8' - 6" EXTEND COL TO EL. 24'-11 1/4"

7
8' - 7 7/8"

8
17' - 1 7/8" EXTEND COL TO EL. 24'-11 1/4" W16X26
SC 1

9
11' - 8 1/4" T.O.S. H.P.T.

10
8' - 6"

11
8' - 6"

12
11' - 8 1/4"

13
16' - 10 3/8" EXTEND COL TO EL. 24'-11 1/4"

14
8' - 6"

15
8' - 6" EXTEND COL TO EL. 24'-11 1/4" W12X19

16 17
4' - 2 1/4" 12' - 8 1/8" EXTEND COL TO EL. 24'-11 1/4" W12X19

18
T.O.S. H.P.T. EXTEND COL TO EL. 24'-11 1/4" T.O.S. H.P.T.

02/05/13 Project North:

S2
Seal:
L IC E N SE D

O FES SIONA L PR

G IN EN
EE R
R. G. GILLARD

TJ.

SC 1

W8x13 12' - 2 7/8"

SC 1

TJ.

W8x13

W8x13
SC 1

TJ.

PROJECT NORTH
5 EQ. SPACES 5 EQ. SPACES W12X16

VI

NC

OF

ON

TA

SC 1

7 EQ. SPACES W12X16 (2 SPAN)

7 EQ. SPACES

SC 1

8 EQ. SPACES

20" DP. OWSJ

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

B
12' - 2 7/8"

- do -

EXTEND COL TO EL. 24'-11 1/4"

5' - 10" TJ. TJ. TJ. W21X44 TJ. W21X50 CANT'L W24X68 CANT'L

5' - 10" W14X22

5' - 9 1/2" TJ. W18X35 CANT'L

W12X16

EXTEND COL TO EL. 24'-11 1/4"

TJ.

TJ.

12' - 2 7/8"

FRAME AROUND ROOF DRAINS AS SHOWN w/ C6x8.2 CHANNELS TYP. COORDINATE EXACT LOCATION WITH MECH'L W12X16 (2 SPAN) 20" DP. OWSJ

T.O.S. L.P.T. @ ROOF DRAIN

T.O.S. L.P.T. @ ROOF DRAIN

W12X16

TYP @ ROOF PERIMETER

2 S6

TJ.

TYP. L3x3x1/4" ROOF BRACE AS SHOWN. Tf/Cf = 4kips - do - do - do - do - do - do -

EXTEND COL TO EL. 24'-11 1/4"

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

D
12' - 2 7/8"

- do -

BF1

5' - 10" TJ. TJ. TJ.

5' - 10" W21X50 CANT'L W24X68 CANT'L W14X22

5' - 10" TJ. W18X35 CANT'L T.O.S. H.P.T. EXTEND COL TO EL. 24'-11 1/4"

TJ.

TJ.

TJ.

TJ.

E
11' - 1"

T.O.S. H.P.T.

W21X44

W8x13 W12X16 (2 SPAN) W12X16 (2 SPAN) 20" DP. OWSJ - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do - do -

F
11' - 0 7/8" EXTEND COL TO EL. 24'-11 1/4" EXTEND COL TO EL. 24'-11 1/4" EXTEND COL TO EL. 24'-11 1/4"

T.O.S. L.P.T. @ ROOF DRAIN 5' - 10"

T.O.S. L.P.T. @ ROOF DRAIN 5' - 9 1/2"

SC 1

SC 1

W12X16

BF2

TJ.

TJ.

TJ.

RTU-1 1400 lbs 13' - 4 1/2" W12X14 5 EQ. SPACES

RTU-2 1400 lbs FRAME AROUND MECHANICAL UNITS AS SHOWN w/ C6x8.2 CHANNELS TYP. COORDINATE EXACT LOCATION WITH MECH'L 4 S6 TYP.

RTU-3 1400 lbs

3 S6 TYP.

TJ.

W12X14

W12X14

W21X44

W21X50 CANT'L

W24X68 CANT'L

W14X22 5' - 10"

W18X35 CANT'L 4 EQ. SPACES 2' - 9 3/4" JOIST MANUFACTURER TO ACCOUNT FOR LOADS OF ALL EQUIPMENT HUNG FROM TOP OR BOTTOM CHORD OF OWSJ IN MECANICAL ROOM. COORDINATE WITH MECH'L & ELEC'L DRAWINGS

1 No. Client:

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

TJ.

TJ.

TJ.

SC 1

RTU-4 1400 lbs

TJ.

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

- do -

H
13' - 4 1/2" W12X14

W12X16 (2 SPAN)

26" DP. OWSJ

22" DP. OWSJ

EXTEND COL TO EL. 24'-11 1/4"

W16X26

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

- do -

SC 1

W8x13
SC 1

W8x13
SC 1

W8x13

C6X8.2 T.O.S. H.P.T. BETWEEN 3 & 18 W12X19 (2 SPAN) TJ.

TJ.

TJ.

TJ.

SC 1

J
T.O.S. H.P.T. + 2"

SC 1

SC 1

C6X8.2

SLOPE 2"

IND; STUB COL. ABOVE, TO EXTEND TO EL. 24'-11 1/4", TYP. U.N.O.

TYP. L3x3x1/4" ROOF BRACE AS SHOWN. Tf/Cf = 4kips

C6X8.2

FRAME AROUND ROOF HATCH AS SHOWN w/ C6x8.2 CHANNELS TYP. COORDINATE EXACT LOCATION WITH ARCH'L

Project Name:

W12X14 EXTEND COL TO EL. 24'-11 1/4"

W12X14 EXTEND COL TO EL. 24'-11 1/4" T.O.S. H.P.T. EXTEND COL TO EL. 24'-11 1/4"

W12X19 (2 SPAN)

T.O.S. H.P.T.

BF4

BF3

T.O.S. H.P.T.

ROOF FRAMING NOTES:

ROOF PLAN 1 1/8" = 1'-0"

1. D E S I G N L O A D S ROOFING & INSULATION STEEL DECK OWSJ's STEEL MECHANICAL / ELECTRICAL DEAD LOAD SNOW LOAD 15 PSF 2 3 5 5 30 PSF 48 PSF PLUS DRIFTING
300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

2. REFER TO DRAWING 'S0' & 'S0.1' FOR GENERAL NOTES & TYPICAL DETAILS. 3. STEEL DECK IS TO BE DESIGNED FOR DIAPHRAGM ACTION TO TRANSFER LATERAL LOADS. REFER TO STEEL NOTES ON DRAWING S0. STEEL DECK TO BE DESIGNED FOR NET FACTORED UPLIFT = 13 psf. 4. ONLY MECHANICAL OPENINGS LARGER THAN 12" x 12" OR 12" ARE SHOWN ON THIS DRAWING. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS NOT SHOWN ON THIS DRAWING. REFER TO TYPICAL DETAILS ON 'S0.1' FOR ADDITIONAL REINFORCING REQUIRED AROUND OPENINGS. 5. ALL OWSJ's TO HAVE 4" DEEP JOISTS SHOES (U/N). ALL OWSJ's TO BE DESIGNED FOR THE SPECIFIED LOADS NOTED PLUS THE WEIGHT OF ROOF-TOP MECHANICAL EQUIPMENT & RELATED SNOW DRIFTING. WIND UPLIFT FOR OWSJ's. (NET FACTORED) = 10 psf 6. ROOF STEEL DECK: c/w L21/2"x21/2"x1/4" PERIMETER ANGLE ALL AROUND, SEE ROOF DECK LAYOUT & LEGEND ON DRAWING S3 FOR SIZE, GAUGE & FASTENING REQUIREMENTS. T.O. STEEL = U.S. OF STEEL DECK @ L.P.T EL. 19'-10 1/8" T.O. STEEL = U.S. OF STEEL DECK @ H.P.T EL. 20'-4 1/8" 7. PARAPETS: (SEE STEEL ELEVATIONS ON DRAWING S3 & S4 FOR MEMBER SIZES) T.O. STEEL (PILASTER PARAPET) = EL. 24'-11 1/4" 8.GIRTS: (SEE STEEL ELEVATIONS ON DRAWING S3 & S4 FOR MEMBER SIZES) REFER TO ARCH'L FOR GIRTS ELEVATIONS

architects inc.
www.farrow-dreessen.com

Drawing:

1/8" = 1'-0"

ROOF PLAN

Project: 131-13025-00 02/05/13

4/5/2013 9:41:40 AM

S2

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

TYPICAL CONT. SHEAR TRANSFER ELEMENT ALONG GRID LINE 'J', GRID 'G' BETWEEN '1' TO '3' & GRID 'A'. SHEAR ELEMENT TO BE CONT. BETWEEN JOISTS, SEE DRAWING S0.1, DETAIL 'U' FOR CLARIFICATION

W12X19 (2 SPAN) 1 S6 TYP @ ROOF PERIMETER

W12X19 EXTEND COL TO EL. 24'-11 1/4"

W16X26 EXTEND COL TO EL. 24'-11 1/4"

W12X19 EXTEND COL TO EL. 24'-11 1/4" EXTEND COL TO EL. 24'-11 1/4"

W12X19 (2 SPAN)

575 INDUSTRIAL AVE. OTTAWA, ON.


OTTAWA TRAIN YARDS, EAST LANDS

RI O

T.O.S. H.P.T.

W16X26

W12X19

W12X19 (3 SPAN)

W12X19

PR

Project: 131-13025-00

18
T.O.S. @ PILASTER PARAPET 24' - 11 1/4" u/s. STEEL DECK @ H.P.T. 20' - 4 1/8" EQ C8X11.5

17 16

15
C8X11.5

14
C8X11.5 CANT'L

13
SEE ARCH'L

12

11

10

9
TYP. 3/8" STIFFNER PL. B.S. WEB @ EACH STUB COL. & BRACE FRAME LOC.

8
C8X11.5 SEE ARCH'L

7
EQ.

6
C8X11.5 (2 SPAN) EQ.

5
C8X11.5

4
SEE ARCH'L

3
C8X11.5 (2 SPAN) SEE ARCH'L

2
C8X11.5

1
T.O.S. @ PILASTER PARAPET 24' - 11 1/4" u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

02/05/13 Project North:

S3
Seal:
L IC E N SE D

O FES SIONA L PR

G IN EN
EE R
R. G. GILLARD

6 S3 u/s. LOW GIRT 10' - 3 3/4"

TYP.

IND; 1/2" DIA. SAG ROD, TYP.

PROJECT NORTH

VI

NC

OF

ON

TA

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY EQ EQ C6X8.2

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY EQ. EQ C6X8.2

HSS6X6X3/8 GIRT

HSS6X6X3/8 GIRT

HSS6X6X3/8 GIRT

HSS7X7X3/8 GIRT

HSS7X7X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY EQ 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY EQ

HSS7X7X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY EQ C6X8.2 EQ HSS6X6X3/8 GIRT TYPICAL CHECK IN FOUNDATION AT ALL DOOR LOC. SEE ARCH'L FOR DOOR SIZE & LOCATION T.O. SLAB 0' - 0"

T.O.S @ u/s OF LOW WINDOW 2' - 0 1/2" T.O. SLAB 0' - 0"

TYPICAL CHECK IN FOUNDATION AT ALL DOOR LOC. SEE ARCH'L FOR DOOR SIZE & LOCATION

EQ

EQ C6X8.2

BUILDING ELEVATION ALONG GRID LINE A 1/8" = 1'-0"

SEE ARCH'L

NORTH - GRID LINE G 1/8" = 1'-0"

1
T.O.S. @ PILASTER PARAPET 24' - 11 1/4" u/s. STEEL DECK @ H.P.T. 20' - 4 1/8" C8X11.5

3
C8X11.5 (2 SPAN) SEE ARCH'L

8
TYP. 3/8" STIFFNER PL. B.S. WEB @ EACH STUB COL. & BRACE FRAME LOC.

9
C8X11.5 (2 SPAN) SEE ARCH'L

10

11
C8X11.5

12

13
C8X11.5 (2 SPAN) SEE ARCH'L

14

15

16 17

18

EQ IND; 1/2" DIA. SAG ROD, TYP. u/s. HIGH GIRT 11' - 3 5/8" HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

EQ

EQ

EQ

EQ

EQ

EQ

EQ

7 "x 7"x 3/8 "

6" x 1/4 "

HSS6X6X3/8 GIRT

HSS6X6X3/8 GIRT

T.O.S. @ u/s OF HIGH WINDOW 3' - 0 1/2" T.O. SLAB 0' - 0"

C6X8.2 EQ EQ EQ

C6X8.2 EQ

OVERSIZE COLUMN POCKETS AT BRACE FRAME S TO ALLOW FOR GUSSET PLATES, TYP.

EQ

EQ C6X8.2

SEE ARCH'L C6X8.2

EQ

EQ C6X8.2

EQ

EQ

EQ C6X8.2

SEE ARCH'L C6X8.2

SEE ARCH'L C6X8.2

EQ

EQ C6X8.2

EQ

EQ C6X8.2

EQ

SEE ARCH'L T.O.S @ u/s OF LOW WINDOW 2' - 0 1/2"

C6X8.2

6"x

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

HSS6X6X3/8 GIRT

u/s. LOW GIRT 10' - 3 3/4"

BF4 Cf/Tf = 150kips

TYPICAL CHECK IN FOUNDATION AT ALL DOOR LOC. SEE ARCH'L FOR DOOR SIZE & LOCATION

BF3 Cf/Tf = 110kips

1 No. Client:

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

SOUTH - GRID LINE J 1/8" = 1'-0"

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

1 A

5
40kips 9' - 10"

7
50kips

9
60kips

10 11 12
60kips 60kips

13
60kips

14 15 16 17 18
45kips 30kips 9' - 10" 71psf 48psf 19kips NO DRIFTING 71psf 48psf

68psf 48psf

SNOW DRIFTING

68psf SNOW DRIFTING 48psf

B C D E F
3kips

19kips

Project Name:
9' - 10" 9' - 10"

SNOW DRIFTING

575 INDUSTRIAL AVE. OTTAWA, ON.


38kips NO DRIFTING 5" 95kips 68psf 3/8" THK GUSSET PLATE @ 16" o/c. FULLY WELDED SAG ROD, SEE ELEVATION FOR SIZE & SPACING HSS GIRT, SEE ELEVATION FOR SIZE & LOCATION 9 7/8" 1 3/4"

38kips

GRID
OTTAWA TRAIN YARDS, EAST LANDS
6"

RI O

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

TYP. 3/8" STIFFNER PL. B.S. WEB @ EACH STUB COL. & BRACE FRAME LOC.

PR

6"x

ZONE 'B'
95kips 48psf

TYPICAL SNOW DRIFTING @ ROOF TOP UNITS 3/16" = 1'-0"

9' - 10"

11 5/8" WIDE x 3/8" THK. PLATE WELDED TO u/s OF GIRT @ WINDOW, SEE ARCH'L FOR EXTENT u/s. LOW GIRT 10' - 3 3/4" U.N.O.

ROOF DECK LEGEND ZONES DESCRIPTION


DECK: 1 1/2"x20ga (SCREWABLE) STEEL DECK OWSJ FASTENERS: HILTI X-EDNK-22 THQ12 NAILS @ 36/9 SIDE LAP: HILTI S-SLC @ 6" o/c. PERIMETER BEAM CONNECTION HILTI X-ENP-19 @ 12" o/c TYP. U.N.O.

300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

ZONE 'A'
50kips 50kips

PLATE TO SPAN OVER WINDOW ONLY, SEE ARCH'L FOR EXTENT

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

G H J
3kips

PLATE DETAIL OVER WINDOW @ DOUBLE STUD WALL 1" = 1'-0"

95kips

48psf SNOW DRIFTING 68psf 7kips

ZONE 'A'
9' - 10" SNOW DRIFTING

48psf 9' - 10"

DECK: 1 1/2"x20ga (SCREWABLE) STEEL DECK OWSJ FASTENERS: HILTI X-EDN-22 THQ12 NAILS @ 36/7 STEEL BEAM FASTENERS HILTI X-EDN-19 THQ12 NAILS @ 36/7 SIDE LAP: HILTI S-SLC @ 9" o/c.

TYPICAL STEEL NOTES: 1. SEE PLANS & SCHEDULES FOR BASE PLATES, COL's & BEAMS STEEL MEMBER SIZES BRACE FRAME TYPICAL NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR DESIGNING ALL CONNECTIONS FOR THE FACTORED LOADS INDICATED IN ACCORDANCE WITH THE OBC AND ALL RELEVANT CSA DOCUMENTS. 2. THE LOADS INDICATED ARE THE FACTORED CONNECTION LOADS TO BE CONSIDERED. ALL LOADS ARE IN ACCORDANCE WITH CL. 27.10 OF CAN/CSA-S16-01 AND 4.1.8 OF THE 2006 OBC. 3. CO-ORDINATE BEAMS, COLUMNS, BASEPLATES & ANCHOR BOLTS WITH FOUNDATION PLAN & SCHEDULES.

architects inc.
www.farrow-dreessen.com

68psf 152kips 120kips 89kips 60kips 60kips 60kips

11kips

60kips

60kips

83kips

94kips

ZONE 'B'

Drawing:

As indicated

BUILDING ELEVATIONS & ROOF DECK LAYOUT

ROOF DECK LAYOUT & SNOW DRIFTING 1/16" = 1'-0"

PERIMETER BEAM CONNECTION - HILTI X-ENP-19 @ 12" o/c TYP. U.N.O. - HILTI X-ENP-19 @ 6" o/c ALONG GRID LINE L, ON GRID 3 FROM A TO L & ALONG GRID LINE 18

Project: 131-13025-00 02/05/13

4/5/2013 9:41:42 AM

S3

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

" 3/8 7" x 7"x

" 1/4 6"x

74kips

60kips

70kips

60kips

74kips

Project: 131-13025-00 02/07/13

S4
Seal:
L IC E N SE D

A
T.O.S. @ PILASTER PARAPET 24' - 11 1/4"

C
TYP. 3/8" STIFFNER PL. B.S. WEB @ EACH STUB COL. & BRACE FRAME LOC.

G
T.O.S. @ PILASTER PARAPET 24' - 11 1/4" u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

G
C8X11.5

H
C8X11.5

J
T.O.S. @ PILASTER PARAPET 24' - 11 1/4"

GRID
CONT. CHANNEL, SEE PLAN & ELEVATIONS FOR MEMBER SIZE

Project North:

O FES SIONA L PR

G IN EN
EE R
R. G. GILLARD

PROJECT NORTH

VI

NC

OF

ON

TA

u/s. LOW GIRT 10' - 3 3/4" OVERSIZE COLUMN POCKETS AT BRACE FRAME S TO ALLOW FOR GUSSET PLATES, TYP. T.O. SLAB 0' - 0"

7"x 7"x 3/8 "

u/s. HIGH GIRT 11' - 3 5/8"

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY

EXTENDED COL. OR STUB COL BEYOND, SEE PLAN & SCHEDULE FOR SIZE & LOCATION

T.O.S. @ u/s OF HIGH WINDOW 3' - 0 1/2" T.O. SLAB 0' - 0"

C6X8.2 EQ EQ EQ

C6X8.2 EQ CONT. PERIMETER ANGLE @ ROOF PERIMETER, SEE ROOF NOTES FOR SIZE u/s. STEEL DECK @ H.P.T. 20' - 4 1/8" STEEL DECK, SEE PLAN

BF1 Cf/Tf = 185kips


1 WEST - GRID LINE 3 1/8" = 1'-0" 2 WEST - GRID LINE 1 1/8" = 1'-0"

CONT. SHEAR TRANSFER ELEMENT, SEE PLAN BEAM, SEE PLAN FOR SIZE

3/8" THK. WEB STIFFENER B.S., TYP @ ALL STUB COL. LOC.

J
T.O.S. @ PILASTER PARAPET 24' - 11 1/4" u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

E
C8X11.5 C8X11.5

D
C8X11.5

C
C8X11.5

B
C8X11.5

OWSJ, SEE PLAN FOR SIZE, SPACING & ORIENTATION

5
TYP. 3/8" STIFFNER PL. B.S. WEB @ EACH STUB COL. & BRACE FRAME LOC.

TYPICAL ROOF SECTION DETAIL @ PARAPET 3/4" = 1'-0"

u/s. LOW GIRT 10' - 3 3/4" TYPICAL CHECK IN FOUNDATION AT ALL DOOR LOC. SEE ARCH'L FOR DOOR SIZE & LOCATION T.O.S @ u/s OF LOW WINDOW 2' - 0 1/2" T.O. SLAB 0' - 0" OVERSIZE COLUMN POCKETS AT BRACE FRAME S TO ALLOW FOR GUSSET PLATES, TYP.

7"x 7"x 3/8 "

HSS6X6X3/8 GIRT c/w HSS6X6X3/8 GIRT c/w 3/8" THK. x 11 5/8" WIDE PL. 3/8" THK. x 11 5/8" WIDE PL. OVER WINDOW ONLY OVER WINDOW ONLY EQ EQ C6X8.2

GRID
CONT. CHANNEL, SEE PLAN & ELEVATIONS FOR MEMBER SIZE T.O.S. @ PILASTER PARAPET 24' - 11 1/4" SEE PLAN CONT. CHANNEL BEYOND, SEE PLAN FOR SIZE

1 No. Client:

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

BF2 Cf/Tf = 185kips


3 BUILDING ELEVATION ALONG GRID LINE 18 1/8" = 1'-0"

EXTENDED COL. OR STUB COL BEYOND, SEE PLAN & SCHEDULE FOR SIZE & LOCATION

STUB COL. BEYOND, SEE PLAN & SCHEDULE FOR SIZE & LOCATION

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

PL. 7"x7"x3/8" THK. FULLY WELDED TO BEAM

1 A B

3
3' - 3"

4
C8X11.5

6
C8X11.5 (2 SPAN)

8
3' - 3" C8X11.5

10 11 12
3' - 3"

13
C8X11.5 CANT'L C8x11.5 1' - 8"

14 15 16 17 18
C8X11.5 C8X11.5 C8X11.5

CONT. PERIMETER ANGLE @ ROOF PERIMETER, SEE ROOF NOTES FOR SIZE u/s. STEEL DECK @ H.P.T. 20' - 4 1/8" CONT. SHEAR TRANSFER ELEMENT, SEE PLAN BEAM, SEE PLAN FOR SIZE

3/8" THK. WEB STIFFENER B.S., TYP @ ALL STUB COL. LOC. BEAM, SEE PLAN FOR SIZE 3/8" THK. WEB STIFFENER B.S., TYP @ ALL STUB COL. LOC.

STEEL DECK, SEE PLAN

C8x11.5 3' - 0"

C8x11.5 3' - 0"

Project Name:

C8X11.5

575 INDUSTRIAL AVE. OTTAWA, ON.


OWSJ, SEE PLAN FOR SIZE, SPACING & ORIENTATION

T.O.S. @ PILASTER PARAPET 24' - 11 1/4" CONT. CHANNEL, SEE PLAN & ELEVATIONS FOR MEMBER SIZE

D
C8x11.5 3' - 0" C8X11.5

TYPICAL PARAPET RETURN DETAIL 3/4" = 1'-0"


300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

E F

STUB COL., SEE PLAN & SCHEDULE FOR SIZE & LOCATION

3' - 3" STEEL DECK, SEE PLAN L6x3 1/2" x 5/16"

Architect:
PL. 7"x7"x3/8" THK. FULLY WELDED TO BEAM

G
C8X11.5

C8X11.5

C8X11.5 CANT'L 3' - 4" 6 S4 3' - 4" C8x11.5 TYP @ PARAPET RETURN 2' - 11 7/8" C8x11.5 C8X11.5 CANT'L 3' - 3" 3' - 3" C8X11.5 3' - 0" C8x11.5 C8X11.5 CANT'L 3' - 3" 7 S4 TYP BEAM CONNECTION OWSJ, SEE PLAN FOR SIZE, SPACING & ORIENTATION u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

TYPICAL STEEL NOTES: 3/8" THK. WEB STIFFENER B.S., TYP @ ALL STUB COL. LOC. 1. SEE PLANS & SCHEDULES FOR BASE PLATES, COL's & BEAMS STEEL MEMBER SIZES BEAM, SEE PLAN FOR SIZE BRACE FRAME TYPICAL NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR DESIGNING ALL CONNECTIONS FOR THE FACTORED LOADS INDICATED IN ACCORDANCE WITH THE OBC AND ALL RELEVANT CSA DOCUMENTS. 2. THE LOADS INDICATED ARE THE FACTORED CONNECTION LOADS TO BE CONSIDERED. ALL LOADS ARE IN ACCORDANCE WITH CL. 27.10 OF CAN/CSA-S16-01 AND 4.1.8 OF THE 2006 OBC. 3. CO-ORDINATE BEAMS, COLUMNS, BASEPLATES & ANCHOR BOLTS WITH FOUNDATION PLAN & SCHEDULES.

H
C8X11.5

architects inc.
www.farrow-dreessen.com

Drawing:

As indicated

C8X11.5

C8X11.5 CANT'L

BUILDING ELEVATIONS & PARAPET FRAMING PLAN

5 S4

TYP @ PARAPET

4
4/5/2013 9:41:44 AM

PARAPET FRAMING PLAN 1/16" = 1'-0"

TYPICAL BEAM CONNECTION AT PARAPET RETURN 3/4" = 1'-0"

Project: 131-13025-00 02/07/13

S4

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

C
C8X11.5

OTTAWA TRAIN YARDS, EAST LANDS

RI O

u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

PR

" 3/8 7"x 7"x

" 3/8 7"x 7"x

Project: 131-13025-00

GRID
CONT. CHANNEL, SEE PLAN FOR SIZE & LOCATION T.O.S @ u/s OF LOW WINDOW 2' - 0 1/2" WINDOW COL. BEYOND, SEE PLAN & SCHEDULE FOR SIZE & LOCATION

GRID

GRID

02/12/13 Project North:

S5
Seal:
L IC E N SE D

O FES SIONA L PR

G IN EN
EE R
R. G. GILLARD

SEE ARCH'L

SEE ARCH'L

T.O. SLAB 0' - 0" EXTERIOR GRADE

PROVIDE CONT. BOND BREAK AT SLAB EDGE, TYP.

T.O. SLAB-ON-GRADE, SEE PLAN T.O. SLAB 0' - 0" EXTERIOR GRADE

PROVIDE BOND BREAK AROUND COL. TYP.

T.O. SLAB-ON-GRADE, SEE PLAN T.O. SLAB 0' - 0" EXTERIOR GRADE 1

SEE ARCH'L

PROVIDE SLAB THICKENING AT DOOR T.O. SLAB-ON-GRADE, SEE PLAN

PROJECT NORTH

VI

NC

OF

ON

TA

10"

1 1 1' - 0"

1 1' - 0" SEE PLAN SEE PLAN REFER TO GEOTECHNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION PIER, SEE PLAN & SCHEDULE/DETAILS FOR REIN'F PROVIDE SLAB THICKENING AT COL. REFER TO GEOTECHNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION SEE PLAN

SEE PLAN REFER TO GEOTECHNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION

TYPICAL FDN-1&3, SEE PLAN & SCHEDULE FOR SIZE & REIN'F 36d LAP MIN.

PIER FOOTING, SEE PLAN & SCHEDULES FOR SIZE & REIN'F WALL FOOTING, SEE PLAN & SCHEDULES FOR SIZE & REIN'F

WALL FOOTING, SEE PLAN & SCHEDULES FOR SIZE & REIN'F

TYPICAL FDN-1&3 SECTION DETAIL 3/4" = 1'-0"

TYPICAL FOUNDATION DETAIL @ PERIMETER PIER 3/4" = 1'-0"

TYPICAL FOUNDATION WALL SECTION DETAIL @ DOOR 3/4" = 1'-0"

GRID

GRID

GRID

36d LAP MIN.

FDN WALL REIN'F WITH: 2-20M T&B CONT. 15M @ 16" o/c. E.F, E.W. + DWLS TO FTG.

VARIEE, SEE PLAN

SEE ARCH'L

SEE ARCH'L

BUILDING COL., SEE PLAN & SCHEDULE FOR SIZE & LOCATION PROVIDE BOND BREAK AROUND COL. TYP. T.O. SLAB-ON-GRADE, SEE PLAN T.O. SLAB 0' - 0" 1 1 1' - 0" 24" MIN. PROVIDE SLAB THICKENING AT COL.

BUILDING COL., SEE PLAN & SCHEDULE FOR SIZE & LOCATION T.O. SLAB-ON-GRADE, SEE PLAN

T.O. SLAB 0' - 0" EXTERIOR GRADE

PROVIDE CONT. BOND BREAK AT SLAB EDGE, TYP.

T.O. SLAB-ON-GRADE, SEE PLAN T.O. SLAB 0' - 0" EXTERIOR GRADE

PROVIDE BOND BREAK AROUND COL. TYP.

1 No. Client:

ISSUED FOR PERMIT Revision Name

2013.03.05 Date

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

SEE PLAN TYPICAL FDN-2&4, SEE PLAN & SCHEDULE FOR SIZE & REIN'F

SEE PLAN

REFER TO GEOTECHNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION

FDN WALL, CONTINUE OUTSIDE FACE REIN'F TROUGHOUT AT PIER

REFER TO GEOTECHNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION

REFER TO GEOTECHNICAL ENGINEER FOR GRANULAR FILL TYPE & COMPACTION PIER, SEE PLAN & SCHEDULE/DETAILS FOR REIN'F

PIER FOOTING, SEE PLAN & SCHEDULES FOR SIZE & REIN'F

36d LAP MIN.

PIER, SEE PLAN & SCHEDULE/DETAILS FOR REIN'F

Project Name:
PIER FOOTING, SEE PLAN & SCHEDULES FOR SIZE & REIN'F

575 INDUSTRIAL AVE. OTTAWA, ON.


OTTAWA TRAIN YARDS, EAST LANDS

TYPICAL FOUNDATION DETAIL @ INTERIOR PIER 3/4" = 1'-0"

TYPICAL FDN-2&4 SECTION DETAIL 3/4" = 1'-0"

TYPICAL FOUNDATION DETAIL @ PERIMETER PIER 3/4" = 1'-0"

300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

architects inc.
www.farrow-dreessen.com

Drawing:

3/4" = 1'-0"

FOUNDATION SECTION DETAILS

Project: 131-13025-00 02/12/13 4/5/2013 9:41:45 AM

S5

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

WALL FOOTING, SEE PLAN & SCHEDULES FOR SIZE & REIN'F

RI O

BUILDING COL., SEE PLAN & SCHEDULE FOR SIZE & LOCATION

PR

Project: 131-13025-00

GRID
CONT. PERIMETER ANGLE @ ROOF PERIMETER, SEE ROOF NOTES FOR SIZE u/s. STEEL DECK @ H.P.T. 20' - 4 1/8" CONT. SHEAR TRANSFER ELEMENT, SEE PLAN BEAM, SEE PLAN FOR SIZE

SEE ELEVATIONS & PARAPET FRAMING PLAN FOR PARAPET LOC. & STEEL MEMBERS

GRID
STEEL DECK, SEE PLAN

02/14/13
STEEL DECK, SEE PLAN

S6
Seal:
L IC E N SE D

Project North:

O FES SIONA L PR

G IN EN
EE R
R. G. GILLARD

TIE JOIST @ COLUMNS, SEE PLAN AND REFER TO TYPICAL DETAILS FROM JOIST MANUFACTURER

PROJECT NORTH
SEE PLAN FOR BEAM SIZES OWSJ, SEE PLAN FOR SIZE & SPACING

VI

NC

OF

ON

TA

COL. BEYOND, SEE PLAN & SCHEDULE FOR SIZE & LOCATION

OWSJ, SEE PLAN FOR SIZE, SPACING & ORIENTATION COL., SEE PLAN & SCHEDULE FOR SIZE & LOCATION SEE PLAN FOR CANT'L

SEE ELEVATIONS & SPECIFIC DETAILS FOR GIRT LOC. & EL.

TYPICAL ROOF SECTION DETAIL - PERPENDICULAR TO JOISTS 3/4" = 1'-0"

TYPICAL TIE-JOIST SECTION DETAIL @ ROOF - PERPENDICULAR TO JOISTS 3/4" = 1'-0"

GRID
CONT. PERIMETER ANGLE @ ROOF PERIMETER, SEE ROOF NOTES FOR SIZE u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

SEE ELEVATIONS & PARAPET FRAMING PLAN FOR PARAPET LOC. & STEEL MEMBERS

STEEL DECK, SEE PLAN

GRID
PROVIDE 2-3/8" WEB STIFFNERS B.S. OF BEAM WEB @ CANT'L BEAM LOC. u/s. STEEL DECK @ H.P.T. 20' - 4 1/8"

STEEL DECK, SEE PLAN

BEAM, SEE PLAN FOR SIZE

COL. BEYOND, SEE PLAN & SCHEDULE FOR SIZE & LOCATION

BEAM BEYOND, SEE PLAN

OWSJ, SEE PLAN FOR SIZE, SPACING & ORIENTATION

TIE JOIST @ COLUMNS, SEE PLAN AND REFER TO TYPICAL DETAILS FROM JOIST MANUFACTURER

SEE PLAN FOR BEAM SIZES

OWSJ, SEE PLAN FOR SIZE & SPACING

COL., SEE PLAN & SCHEDULE FOR SIZE & LOCATION

SEE ELEVATIONS & SPECIFIC DETAILS FOR GIRT LOC. & EL.

TYPICAL ROOF SECTION DETAIL - PARALLEL TO JOISTS 3/4" = 1'-0"

TYPICAL TIE-JOIST SECTION DETAIL @ ROOF - PARALLEL TO JOISTS 3/4" = 1'-0"


1 No. Client: ISSUED FOR PERMIT Revision Name 2013.03.05 Date

CONTROLEX CORP.
TEL: 613-723-7490 FAX: 613-723-7483

Project Name:

575 INDUSTRIAL AVE. OTTAWA, ON.


OTTAWA TRAIN YARDS, EAST LANDS

RI O

PROVIDE 2-3/8" WEB STIFFNERS B.S. OF BEAM WEB @ CANT'L BEAM LOC.

300-2611 QUEENSVIEW DRIVE, OTTAWA (ONTARIO) K2B 8K2 FAX: 613-829-8299 PHONE: 613-829-2800 WWW.GENIVAR.COM

Architect:
1350 Wellington Street W. Ottawa .Ontario. K1Y 3C1 P.+1.613.725.2294 F.+1.613.724.6632

architects inc.
www.farrow-dreessen.com

Drawing:

3/4" = 1'-0"

STEEL SECTION DETAILS

Project: 131-13025-00 02/14/13 4/5/2013 9:41:46 AM

S6

C:\Users\mitchel.lavallee\Documents\131-13025-00_Structural_mitchel.lavallee.rvt

PR

Das könnte Ihnen auch gefallen