eNodeB V100R005C00

Parameter Reference
Issue Date 01 2012/05/11

HUAWEI TECHNOLOGIES CO., LTD.

Copyright Huawei Technologies Co., Ltd. 2012. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice

The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part o products, services and features described in this document may not be within the purchase scope or the usage scope. Unless other specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warrantie guarantees or representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the preparation of this documen ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warrant kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China http://www.huawei.com support@huawei.com

Website: Email:

ans without prior written consent of Huawei

their respective holders.

etween Huawei and the customer. All or part of the chase scope or the usage scope. Unless otherwise cument are provided "AS IS" without warranties,

been made in the preparation of this document to ns in this document do not constitute a warranty of any

Purpose

This document describes the MO parameters of eNodeB. For the details about the parameters rela parameter list.

Intended Audience
This document is intended for: Network planners System engineers Field engineers Shift operators Site maintainers Network operators

Parameter Attribute Description


The following table describes the attributes of each parameter. Parameter Attribute MO Parameter ID Parameter Name NE MML Command Meaning IsKey Mandatory Dynamic Attribute Feature ID Feature Name Value Type GUI Value Range Enumeration Number/Bit Unit Actual Value Range

Default Value

Recommended Value

Initial Value Source

Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution Validation of Modification Impact on Radio Network Performance Introduced in Version Attribute

Change History
For detailed parameter changes, see the release notes.
Issue 03 02 01 Draft B Draft A Date 2012/5/11 2012/4/28 2012/3/30 2012/2/15 2012/1/10

cribes the MO parameters of eNodeB. For the details about the parameters related to northbound interface interconnection, see

e Description

describes the attributes of each parameter. Description Managed object of NE. A simple character string used for identifying a parameter. Name of a parameter. NEs on which the parameter is set. Man Machine Language (MML) command related to the parameter. Definition, purpose, and protocols of the parameter. Whether the parameter is used to identify an MO instance. Whether the parameter is mandatory for creating an MO instance. Whether the parameter is dynamic for an MO. If the parameter is not dynamic, it can be added, modified, or removed; if the parameter is dynamic, it cannot. ID of the feature that uses the parameter. Name of the feature that uses the parameter. Type of a parameter value. Range of the parameter values displayed on the GUI. Enumeration number corresponding to the GUI value of a parameter of the enumeration type, or Unit of a parameter value displayed on the GUI. Range of the actual values corresponding to the parameter values displayed on the GUI. Initial value assigned by the system for a parameter. For a mandatory parameter, no default value is available. For a bit field parameter, if the value of a sub-parameter is ON, the bit representing the sub-parameter is set to 1; if the value of a sub-parameter is OFF, the bit representing the subparameter is set to 0. None indicates that no default value is available. Generally, it is displayed on the configuration window of an ADD command but not displayed on the configuration window of a MOD/RMV/DSP/LST command. Parameter values recommended for different scenarios.

Source for the initial configuration of a parameter. The initial value source can be: Radio planning (Internal planning): The parameter value comes from the radio network plan, facilitating resource management on the NE. Radio planning (Negotiation with the peer): The parameter value comes from the radio network plan. The NE negotiates this value with the peer device to ensure successful interworking. Transport planning (Internal planning): The parameter value comes from the transport network plan, facilitating resource management on the NE. Transport planning (Negotiation with the peer): The parameter value comes from the transport network plan. The NE negotiates this value with the peer device to ensure successful interworking. Equipment planning: The parameter value comes from the equipment plan. Engineering design: The parameter value comes from the algorithm or function design. Default/recommended value: The parameter value uses the default or recommended value, where the recommended value is preferential. The default/recommended value can be used in most scenarios and adjusted for a specific scenario. N/A: The parameter value is not required. Parameter impact scope. Relationship with other parameters. For example, to use this parameter, you need to set related Whether this parameter is Read & Write or Read Only. If a parameter is not dynamic and is read only, it can be set only when the MO is created and cannot be modified later. To modify the parameter, you must delete the MO first and then create it again. Whether modifying the parameter value interrupts the ongoing services. Possible interruption scope. Possible interruption duration (unit: minute). Cautions to be taken during the modification. How this parameter takes effect and whether the equipment needs to be restarted after the Impact of the parameter on radio network performance. Product version in which the parameter is introduced. Whether the parameter is a radio parameter, a transport parameter, or an equipment parameter.

eter changes, see the release notes.


Description This is the third official release. This is the second official release. This is the first official release. This is the draft. This is the draft.

t the parameters related to northbound interface interconnection, see the

fying a parameter.

nd related to the parameter. parameter. fy an MO instance. r creating an MO instance. n MO. If the parameter is not dynamic, it can be added, s dynamic, it cannot. r. meter.

d on the GUI. he GUI value of a parameter of the enumeration type, or he GUI. ng to the parameter values displayed on the GUI. a parameter. For a mandatory parameter, no default value he value of a sub-parameter is ON, the bit representing e of a sub-parameter is OFF, the bit representing the subat no default value is available. ation window of an ADD command but not displayed on V/DSP/LST command.

erent scenarios.

arameter. The initial value source can be: parameter value comes from the radio network plan, e NE. er): The parameter value comes from the radio network the peer device to ensure successful interworking. The parameter value comes from the transport network on the NE. e peer): The parameter value comes from the transport lue with the peer device to ensure successful

ue comes from the equipment plan. ue comes from the algorithm or function design. meter value uses the default or recommended value, ential. The default/recommended value can be used in fic scenario. d.

example, to use this parameter, you need to set related e or Read Only. If a parameter is not dynamic and is read created and cannot be modified later. To modify the and then create it again. interrupts the ongoing services.

ute). ation. ether the equipment needs to be restarted after the rk performance.

is introduced. meter, a transport parameter, or an equipment parameter.

MO

Parameter ID

Parameter Name

NE

MML Command ADD BFANT DSP BFANT LST BFANT MOD BFANT RMV BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT DSP BFANT LST BFANT ADD BFANT MOD BFANT LST BFANT

BFANT

DEVICENO

Device No.

eNodeB

BFANT

CONNCN

Connect RRU cabinet No.

eNodeB

BFANT

CONNSRN

Connect RRU subrack No.

eNodeB

BFANT

CONNSN

Connect RRU slot No.

eNodeB

BFANT

MODELNO

Antenna model number

eNodeB

BFANT

TILT

Tilt

eNodeB

BFANT

BEAMWIDTH

Beamwidth

eNodeB

BFANT

Band

Band

eNodeB

BFANT

TYPE

Antenna Type

eNodeB

BFANT

POLARMODE

Polar Mode

eNodeB

DSP BFANT

BFANT

ELMTBMWTH

Element Beamform eNodeB Width

None

BFANT

AntPortNum

Number of Port

eNodeB

DSP BFANT

BFANT

CRS2Amp1

Amplitude Offset of Physical Port 1 for eNodeB CRS2

DSP BFANT

BFANT

CRS2Pha1

Phase of Physical Port 1 for CRS2

eNodeB

DSP BFANT

BFANT

CRS2Amp2

Amplitude Offset of Physical Port 2 for eNodeB CRS2

DSP BFANT

BFANT

CRS2Pha2

Phase of Physical Port 2 for CRS2

eNodeB

DSP BFANT

BFANT

CRS2Amp3

Amplitude Offset of Physical Port 3 for eNodeB CRS2

DSP BFANT

BFANT

CRS2Pha3

Phase of Physical Port 3 for CRS2

eNodeB

DSP BFANT

BFANT

CRS2Amp4

Amplitude Offset of Physical Port 4 for eNodeB CRS2

DSP BFANT

BFANT

CRS2Pha4

Phase of Physical Port 4 for CRS2

eNodeB

DSP BFANT

BFANT

CRS4Amp1

Amplitude Offset of Physical Port 1 for eNodeB CRS4

DSP BFANT

BFANT

CRS4Pha1

Phase of Physical Port 1 for CRS4

eNodeB

DSP BFANT

BFANT

CRS4Amp2

Amplitude Offset of Physical Port 2 for eNodeB CRS4

DSP BFANT

BFANT

CRS4Pha2

Phase of Physical Port 2 for CRS4

eNodeB

DSP BFANT

eNodeB

ENODEBID

eNodeB ID

eNodeB

MOD ENODEB DSP ENODEB LST ENODEB

eNodeB

NAME

eNodeB name

eNodeB

MOD ENODEB LST ENODEB

eNodeB

ENBTYPE

eNodeB type

eNodeB

MOD ENODEB LST ENODEB

eNodeB

AUTOPOWEROFF Auto power control SWITCH switch

eNodeB

MOD ENODEB LST ENODEB

eNodeB

POWEROFFTIME

Auto power off time eNodeB

MOD ENODEB LST ENODEB

eNodeB

POWERONTIME

Auto power on time eNodeB

MOD ENODEB LST ENODEB

eNodeB

LONGITUDE

Longitude

eNodeB

MOD ENODEB LST ENODEB

eNodeB

LATITUDE

Latitude

eNodeB

MOD ENODEB LST ENODEB

eNodeB

ElectriSerialNo

Electronic Serial Number

eNodeB

DSP ENODEB

eNodeB

LicenseState

LicenseState

eNodeB

DSP ENODEB

eNodeB

AutoPoweroffStatus

eNodeB eNodeB autopoweroff status

DSP ENODEB

eNodeB

LOCATION

Site Location

eNodeB

MOD ENODEB LST ENODEB

eNodeB

GCDF

Geo-coordinate data format

eNodeB

MOD ENODEB LST ENODEB

eNodeB

LATITUDESECFO RMAT

Latitude with second format

eNodeB

MOD ENODEB LST ENODEB

eNodeB

LONGITUDESECF Longitude with ORMAT second format

eNodeB

MOD ENODEB LST ENODEB

eNodeB

PROTOCOL

Protocol Type

eNodeB

MOD ENODEB LST ENODEB

KPIALARM

KPITYPE

KPITYPE

eNodeB

LST KPIALARM MOD KPIALARM

KPIALARM

REPORTSWITCH

Report Switch

eNodeB

MOD KPIALARM LST KPIALARM

KPIALARM

FLTTHRESHOLD

FltThreshold

eNodeB

MOD KPIALARM LST KPIALARM

KPIALARM

RESTHRESHOLD

ResThreshold

eNodeB

MOD KPIALARM LST KPIALARM

KPIALARM

MINCHECKTIMES MinCheckTimes

eNodeB

MOD KPIALARM LST KPIALARM

KPIALARM

DETECTPERIOD

DetectPeriod

eNodeB

MOD KPIALARM LST KPIALARM

KPIALARM

DETECTBEGINTIM DetectBeginTime E

eNodeB

MOD KPIALARM LST KPIALARM

KPIALARM

DETECTPERIODN DetectPeriodNum UM

eNodeB

MOD KPIALARM LST KPIALARM ADD SECTOR DSP SECTOR LST SECTOR MOD SECTOR RMV SECTOR

Sector

SECN

Sector No.

eNodeB

Sector

LONGITUDE

Longitude

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

LATITUDE

Latitude

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

ANTM

Antenna mode

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SECM

Sector mode

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

COMBM

CombMode

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN1

Cabinet No. of the RRU where antenna port 1 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN1

Subrack No. of the RRU where antenna port 1 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN1

Slot No. of the RRU where antenna port eNodeB 1 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN1

Port No. of antenna eNodeB connector 1

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN2

Cabinet No. of the RRU where antenna port 2 is located Subrack No. of the RRU where antenna port 2 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN2

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN2

Slot No. of the RRU where antenna port eNodeB 2 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN2

Port No. of antenna eNodeB connector 2

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN3

Cabinet No. of the RRU where antenna port 3 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN3

Subrack No. of the RRU where antenna port 3 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN3

Slot No. of the RRU where antenna port eNodeB 3 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN3

Port No. of antenna eNodeB connector 3

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN4

Cabinet No. of the RRU where antenna port 4 is located Subrack No. of the RRU where antenna port 4 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN4

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN4

Slot No. of the RRU where antenna port eNodeB 4 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN4

Port No. of antenna eNodeB connector 4

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN5

Cabinet No. of the RRU where antenna port 5 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN5

Subrack No. of the RRU where antenna port 5 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN5

Slot No. of the RRU where antenna port eNodeB 5 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN5

Port No. of antenna eNodeB connector 5

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN6

Cabinet No. of the RRU where antenna port 6 is located Subrack No. of the RRU where antenna port 6 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN6

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN6

Slot No. of the RRU where antenna port eNodeB 6 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN6

Port No. of antenna eNodeB connector 6

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN7

Cabinet No. of the RRU where antenna port 7 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN7

Subrack No. of the RRU where antenna port 7 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN7

Slot No. of the RRU where antenna port eNodeB 7 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN7

Port No. of antenna eNodeB connector 7

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN8

Cabinet No. of the RRU where antenna port 8 is located Subrack No. of the RRU where antenna port 8 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN8

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN8

Slot No. of the RRU where antenna port eNodeB 8 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN8

Port No. of antenna eNodeB connector 8

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN9

Cabinet No. of the RRU where antenna port 9 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN9

Subrack No. of the RRU where antenna port 9 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN9

Slot No. of the RRU where antenna port eNodeB 9 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN9

Port No. of antenna eNodeB connector 9

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN10

Cabinet No. of the RRU where antenna port 10 is located Subrack No. of the RRU where antenna port 10 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN10

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN10

Slot No. of the RRU where antenna port eNodeB 10 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN10

Port No. of antenna eNodeB connector 10

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN11

Cabinet No. of the RRU where antenna port 11 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN11

Subrack No. of the RRU where antenna port 11 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN11

Slot No. of the RRU where antenna port eNodeB 11 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN11

Port No. of antenna eNodeB connector 11

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN12

Cabinet No. of the RRU where antenna port 12 is located Subrack No. of the RRU where antenna port 12 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN12

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN12

Slot No. of the RRU where antenna port eNodeB 12 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN12

Port No. of antenna eNodeB connector 12

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SECTORNAME

Sector name

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

ALTITUDE

Altitude

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

UNCERTSEMIMAJ UncertSemiMajor OR

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

UNCERTSEMIMIN UncertSemiMinor OR

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

ORIENTOFMAJOR OrientOfMajorAxis AXIS

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

UNCERTALTITUD UncertAltitude E

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CONFIDENCE

Confidence

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

GCDF

Geo-coordinate data format

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR ADD SECTOR MOD SECTOR LST SECTOR

Sector

ANTLATITUDESEC Antenna latitude FORMAT with second format

eNodeB

Sector

ANTLONGITUDES Antenna longitude ECFORMAT with second format

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

OMNIFLAG

Omni Mode

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN13

Cabinet No. of the RRU where antenna port 13 is located Subrack No. of the RRU where antenna port 13 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN13

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN13

Slot No. of the RRU where antenna port eNodeB 13 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN13

Port No. of antenna eNodeB connector 13

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN14

Cabinet No. of the RRU where antenna port 14 is located Subrack No. of the RRU where antenna port 14 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN14

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN14

Slot No. of the RRU where antenna port eNodeB 14 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN14

Port No. of antenna eNodeB connector 14

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN15

Cabinet No. of the RRU where antenna port 15 is located Subrack No. of the RRU where antenna port 15 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN15

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN15

Slot No. of the RRU where antenna port eNodeB 15 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN15

Port No. of antenna eNodeB connector 15

ADD SECTOR MOD SECTOR LST SECTOR

Sector

CN16

Cabinet No. of the RRU where antenna port 16 is located Subrack No. of the RRU where antenna port 16 is located

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SRN16

eNodeB

ADD SECTOR MOD SECTOR LST SECTOR

Sector

SN16

Slot No. of the RRU where antenna port eNodeB 16 is located

ADD SECTOR MOD SECTOR LST SECTOR

Sector

PN16

Port No. of antenna eNodeB connector 16

ADD SECTOR MOD SECTOR LST SECTOR

Sector

MaxTxPower

Maximum transmit power of each TX channel

eNodeB

DSP SECTOR

Sector

LicState

License state

eNodeB

DSP SECTOR

Sector

RXFrequencyRange

RX Frequency Range

eNodeB

DSP SECTOR

Sector

TXFrequencyRange

TX Frequency Range

eNodeB

DSP SECTOR

WEBLOGINPOLICY POLICY

WebLMT Login Policy

eNodeB

SET WEBLOGINPOLIC Y LST WEBLOGINPOLIC Y

ALD

DEVICENO

Device No.

eNodeB

DLD ALDSW DSP ALDVER RST ALD

ALD

RtmVendorCode

Actual Vendor Code eNodeB

None

ALD

RtmDeviceSerialNo

Actual Device Serial eNodeB No.

DSP ALDVER

ALD

DEVICENAME

Device Name

eNodeB

DSP ALDVER

ALD

CTRLCN

Control Port Cabinet No.

eNodeB

DLD ALDSW DLD RETCFGDATA DSP ALDVER RST ALD SCN ALD

ALD

CTRLSRN

Control Port Subrack No.

eNodeB

DLD ALDSW DLD RETCFGDATA DSP ALDVER RST ALD SCN ALD

ALD

CTRLSN

Control Port Slot No.

eNodeB

DLD ALDSW DLD RETCFGDATA DSP ALDVER RST ALD SCN ALD

ALD

ProtocolVersion

Protocol Version

eNodeB

DSP ALDVER

ALD

RtmTotalSubunitNu Actual Subunit m Number

eNodeB

None

ALD

VENDORCODE

Vendor Code

eNodeB

None

ALD

SERIALNO

Serial No.

eNodeB

None

ALD

HardwareVersion

Hardware Version

eNodeB

DSP ALDVER

ALD

SoftwareVersion

Software Version

eNodeB

DSP ALDVER

ALD

DeviceModel

Device Model

eNodeB

DSP ALDVER

ALD

DeviceType

Device Type

eNodeB

DSP ALDVER

ALD

CtrlPortNo

Control Port No.

eNodeB

None

AntennaPort

CN

Cabinet No.

eNodeB

DSP ANTENNAPORT LST ANTENNAPORT MOD ANTENNAPORT

AntennaPort

SRN

Subrack No.

eNodeB

DSP ANTENNAPORT LST ANTENNAPORT MOD ANTENNAPORT

AntennaPort

SN

Slot No.

eNodeB

DSP ANTENNAPORT LST ANTENNAPORT MOD ANTENNAPORT

AntennaPort

PN

Port No.

eNodeB

DSP ANTENNAPORT LST ANTENNAPORT MOD ANTENNAPORT MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

FEEDERLENGTH

Feeder Length

eNodeB

AntennaPort

DLDELAY

TMA Downlink Delay

eNodeB

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

DUDELAY

TMA Uplink Delay

eNodeB

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

PWRSWITCH

ALD Power Switch

eNodeB

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

Current Alarm THRESHOLDTYPE Threshold Type

eNodeB

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

UOTHD

Undercurrent Alarm eNodeB Occur Threshold

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

UCTHD

Undercurrent Alarm eNodeB Clear Threshold

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

OOTHD

Overcurrent Alarm Occur Threshold

eNodeB

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

OCTHD

Overcurrent Alarm Clear Threshold

eNodeB

MOD ANTENNAPORT LST ANTENNAPORT

AntennaPort

ALDCurrValue

ALD Current Value eNodeB

DSP ANTENNAPORT DSP ANTENNAPORT ADD RET MOD RET MOD RETTILT LST RET

AntennaPort

ALDRtmPwrSwitch

ALD Actual Power Switch

eNodeB

RET

RETTYPE

RET Type

eNodeB

RET

POLARTYPE

Polar Type

eNodeB

ADD RET MOD RET LST RET

RET

SCENARIO

Antenna Scenario

eNodeB

ADD RET MOD RET LST RET

RET

SUBUNITNUM

RET Subunit Number

eNodeB

ADD RET MOD RET LST RET None ADD RET DSP RET LST RET MOD RET RMV RET DSP RET

RET

RETCLASS

RET Class

eNodeB

RET

DEVICENO

Device No.

eNodeB

RET

RtmVendorCode

Actual Vendor Code eNodeB

RET

RtmDeviceSerialNo

Actual Device Serial eNodeB No.

DSP RET

RET

DEVICENAME

Device Name

eNodeB

ADD RET MOD RET LST RET

RET

CTRLCN

Control Port Cabinet No.

eNodeB

ADD RET MOD RET DSP RET LST RET

RET

CTRLSRN

Control Port Subrack No.

eNodeB

ADD RET MOD RET DSP RET LST RET

RET

CTRLSN

Control Port Slot No.

eNodeB

ADD RET MOD RET DSP RET LST RET

RET

ProtocolVersion

Protocol Version

eNodeB

None

RET

RtmTotalSubunitNu Actual Subunit m Number

eNodeB

DSP RET

RET

VENDORCODE

Vendor Code

eNodeB

ADD RET MOD RET LST RET

RET

SERIALNO

Serial No.

eNodeB

ADD RET MOD RET LST RET

RET

HardwareVersion

Hardware Version

eNodeB

None

RET

SoftwareVersion

Software Version

eNodeB

None

RET

DeviceModel

Device Model

eNodeB

None

RET

DeviceType

Device Type

eNodeB

None

RET

CtrlPortNo

Control Port No.

eNodeB

DSP RET

RetDeviceData

DEVICENO

Device No.

eNodeB

DSP RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA

RetDeviceData

SUBUNITNO

Subunit No.

eNodeB

DSP RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA

RetDeviceData

BEARING

Antenna Bearing

eNodeB

MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

MODELNO

Antenna Model Number

eNodeB

RetDeviceData

BSID

Base Station ID

eNodeB

MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BEAMWIDTH1

Beamwidth1

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BEAMWIDTH2

Beamwidth2

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BEAMWIDTH3

Beamwidth3

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BEAMWIDTH4

Beamwidth4

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

GAIN1

Gain1

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

GAIN2

Gain2

eNodeB

RetDeviceData

GAIN3

Gain3

eNodeB

RetDeviceData

GAIN4

Gain4

eNodeB

RetDeviceData

DATE

Installation Date

eNodeB

RetDeviceData

TILT

Installed Mechanical Tilt

eNodeB

RetDeviceData

INSTALLERID

Installer's ID

eNodeB

RetDeviceData

BAND1

Band1

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BAND2

Band2

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BAND3

Band3

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

BAND4

Band4

eNodeB

MOD RETDEVICEDATA LST RETDEVICEDATA

RetDeviceData

SECTORID

Sector ID

eNodeB

MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA MOD RETDEVICEDATA DSP RETDEVICEDATA LST RETDEVICEDATA DSP RETDEVICEDATA

RetDeviceData

SERIALNO

Antenna Serial No. eNodeB

RetDeviceData

MaxTilt

Max Tilt

eNodeB

RetDeviceData

MinTilt

Min Tilt

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmOpBandCodes1 Band1

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmOpBandCodes2 Band2

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmOpBandCodes3 Band3

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmOpBandCodes4 Band4

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmBeamWidth1

Beamwidth1

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmBeamWidth2

Beamwidth2

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmBeamWidth3

Beamwidth3

eNodeB

DSP RETDEVICEDATA

RetDeviceData

RtmBeamWidth4

Beamwidth4

eNodeB

DSP RETDEVICEDATA

RetDeviceData RetDeviceData RetDeviceData RetDeviceData

RtmGainValue1 RtmGainValue2 RtmGainValue3 RtmGainValue4

Gain1 Gain2 Gain3 Gain4

eNodeB eNodeB eNodeB eNodeB

DSP RETDEVICEDATA DSP RETDEVICEDATA DSP RETDEVICEDATA DSP RETDEVICEDATA DSP RETPORT LST RETPORT MOD RETPORT DSP RETPORT LST RETPORT MOD RETPORT

RetPort

CN

Cabinet No.

eNodeB

RetPort

SRN

Subrack No.

eNodeB

RetPort

SN

Slot No.

eNodeB

DSP RETPORT LST RETPORT MOD RETPORT

RetPort

PN

Port No.

eNodeB

DSP RETPORT LST RETPORT MOD RETPORT

RetPort

PWRSWITCH

ALD Power Switch

eNodeB

MOD RETPORT LST RETPORT

RetPort

THRESHOLDTYPE

Current Alarm Threshold

eNodeB

MOD RETPORT LST RETPORT

RetPort

UOTHD

Undercurrent Alarm eNodeB Occur Threshold

MOD RETPORT LST RETPORT

RetPort

UCTHD

Undercurrent Alarm eNodeB Clear Threshold

MOD RETPORT LST RETPORT

RetPort

OOTHD

Overcurrent Alarm Occur Threshold

eNodeB

MOD RETPORT LST RETPORT

RetPort

OCTHD

Overcurrent Alarm Clear Threshold

eNodeB

MOD RETPORT LST RETPORT

RetPort

ALDCurrValue

ALD Current Value eNodeB

DSP RETPORT

RetPort

ALDRtmPwrSwitch

ALD Actual Power Switch

eNodeB

DSP RETPORT CLB RET DLD RETCFGDATA DSP RETSUBUNIT LST RETSUBUNIT MOD RETSUBUNIT CLB RET DLD RETCFGDATA DSP RETSUBUNIT LST RETSUBUNIT MOD

RETSubunit

DEVICENO

Device No.

eNodeB

RETSubunit

SUBUNITNO

Subunit No.

eNodeB

RETSubunit

Status

Online Status

eNodeB

DSP RETSUBUNIT

RETSubunit

RtmTilt

Actual Tilt

eNodeB

DSP RETSUBUNIT

RETSubunit

RtmSectorId

Sector Id

eNodeB

DSP RETSUBUNIT

RETSubunit

CONNCN1

Connect Port 1 Cabinet No.

eNodeB

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNSRN1

Connect Port 1 Subrack No.

eNodeB

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNSN1

Connect Port 1 Slot eNodeB No.

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNPN1

Connect Port 1 Port eNodeB No.

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNCN2

Connect Port 2 Cabinet No.

eNodeB

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNSRN2

Connect Port 2 Subrack No.

eNodeB

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNSN2

Connect Port 2 Slot eNodeB No.

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

CONNPN2

Connect Port 2 Port eNodeB No.

MOD RETSUBUNIT LST RETSUBUNIT

RETSubunit

TILT

Tilt

eNodeB

MOD RETSUBUNIT MOD RETTILT LST RETSUBUNIT

RETSubunit

AER

Tilt Alarm Error Range

eNodeB

MOD RETSUBUNIT LST RETSUBUNIT MOD RETSUBUNIT MOD RETTILT LST RETSUBUNIT ADD TMA MOD TMA LST TMA ADD TMA DSP TMA LST TMA MOD TMA RMV TMA DSP TMA

RETSubunit

SUBNAME

Subunit Name

eNodeB

TMA

SUBUNITNUM

TMA Subunit Number

eNodeB

TMA

DEVICENO

Device No.

eNodeB

TMA

RtmVendorCode

Actual Vendor Code eNodeB

TMA

RtmDeviceSerialNo

Actual Device Serial eNodeB No.

DSP TMA

TMA

DEVICENAME

Device Name

eNodeB

ADD TMA MOD TMA LST TMA

TMA

CTRLCN

Control Port Cabinet No.

eNodeB

ADD TMA MOD TMA DSP TMA LST TMA

TMA

CTRLSRN

Control Port Subrack No.

eNodeB

ADD TMA MOD TMA DSP TMA LST TMA

TMA

CTRLSN

Control Port Slot No.

eNodeB

ADD TMA MOD TMA DSP TMA LST TMA

TMA

ProtocolVersion

Protocol Version

eNodeB

None

TMA

RtmTotalSubunitNu Actual Subunit m Number

eNodeB

DSP TMA

TMA

VENDORCODE

Vendor Code

eNodeB

ADD TMA MOD TMA LST TMA

TMA

SERIALNO

Serial No.

eNodeB

ADD TMA MOD TMA LST TMA

TMA

HardwareVersion

Hardware Version

eNodeB

None

TMA

SoftwareVersion

Software Version

eNodeB

None

TMA

DeviceModel

Device Model

eNodeB

None

TMA

DeviceType

Device Type

eNodeB

None

TMA

CtrlPortNo

Control Port No.

eNodeB

DSP TMA

TMADeviceData

DEVICENO

Device No.

eNodeB

DSP TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

SUBUNITNO

Subunit No.

eNodeB

TMADeviceData

BEARING

Antenna Bearing

eNodeB

TMADeviceData

BSID

Base Station ID

eNodeB

TMADeviceData

BEAMWIDTH1

Beamwidth1

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

BEAMWIDTH2

Beamwidth2

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

BEAMWIDTH3

Beamwidth3

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

BEAMWIDTH4

Beamwidth4

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

GAIN1

Gain1

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

GAIN2

Gain2

eNodeB

TMADeviceData

GAIN3

Gain3

eNodeB

TMADeviceData

GAIN4

Gain4

eNodeB

TMADeviceData

DATE

Installation Date

eNodeB

TMADeviceData

TILT

Installed Mechanical Tilt

eNodeB

MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

INSTALLERID

Installer's ID

eNodeB

TMADeviceData

BAND1

Band1

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

BAND2

Band2

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

BAND3

Band3

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

BAND4

Band4

eNodeB

MOD TMADEVICEDATA LST TMADEVICEDATA

TMADeviceData

SECTORID

Sector ID

eNodeB

MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA MOD TMADEVICEDATA DSP TMADEVICEDATA LST TMADEVICEDATA DSP TMADEVICEDATA

TMADeviceData

SERIALNO

Serial No.

eNodeB

TMADeviceData

MODELNO

Connect Antenna Model Number

eNodeB

TMADeviceData

MaxSupportedGain

Max Supported Gain

eNodeB

TMADeviceData

MinSupportedGain

Min Supported Gain eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmTmaSubunitTyp Real Subunit type e

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmTmaGainResol Real Gain ution Resolution

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmOpBandCode1 Band1

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmOpBandCode2 Band2

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmOpBandCode3 Band3

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmOpBandCode4 Band4

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmBeamWidth1

Beamwidth1

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmBeamWidth2

Beamwidth2

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmBeamWidth3

Beamwidth3

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmBeamWidth4

Beamwidth4

eNodeB

DSP TMADEVICEDATA

TMADeviceData TMADeviceData

RtmGainValue1 RtmGainValue2

Gain1 Gain2

eNodeB eNodeB

DSP TMADEVICEDATA DSP TMADEVICEDATA

TMADeviceData TMADeviceData

RtmGainValue3 RtmGainValue4

Gain3 Gain4

eNodeB eNodeB

DSP TMADEVICEDATA DSP TMADEVICEDATA

TMADeviceData

RtmTmaRxMinFreB Real Received Min eNodeB and Frequency Band

DSP TMADEVICEDATA

TMADeviceData

RtmTmaTxMaxFreB Real Transmit Max eNodeB and Frequency Band

DSP TMADEVICEDATA

TMADeviceData

RtmTmaTxMinFreB Real Transmit Min and Frequency Band

eNodeB

DSP TMADEVICEDATA

TMADeviceData

RtmTmaRxMaxFre Real Received Max eNodeB Band Frequency Band

DSP TMADEVICEDATA

TMASubunit

DEVICENO

Device No.

eNodeB

TMASubunit

SUBUNITNO

Subunit No.

eNodeB

DSP TMASUBUNIT LST TMASUBUNIT MOD TMASUBUNIT DSP TMASUBUNIT LST TMASUBUNIT MOD TMASUBUNIT DSP TMASUBUNIT

TMASubunit

RtmSectorId

Actual Sector ID

eNodeB

TMASubunit

RtmGain

Actual Gain

eNodeB

DSP TMASUBUNIT

TMASubunit

RtmMode

Actual Mode

eNodeB

DSP TMASUBUNIT

TMASubunit

Status

Online Status

eNodeB

DSP TMASUBUNIT

TMASubunit

CONNPN

Connect Port No.

eNodeB

MOD TMASUBUNIT LST TMASUBUNIT

TMASubunit

CONNCN

Connect Port Cabinet No.

eNodeB

MOD TMASUBUNIT LST TMASUBUNIT

TMASubunit

CONNSN

Connect Port Slot No.

eNodeB

MOD TMASUBUNIT LST TMASUBUNIT

TMASubunit

CONNSRN

Connect Port Subrack No.

eNodeB

MOD TMASUBUNIT LST TMASUBUNIT

TMASubunit

GAIN

Gain

eNodeB

MOD TMASUBUNIT LST TMASUBUNIT

TMASubunit

MODE

Mode

eNodeB

MOD TMASUBUNIT LST TMASUBUNIT

VAntennaPort

CONNCN

Cabinet No.

eNodeB

None

VAntennaPort

CONNSRN

Subrack No.

eNodeB

None

VAntennaPort

CONNSN

Slot No.

eNodeB

None

VAntennaPort

PN

Port No.

eNodeB

None

VRET

DEVICENO

Device No.

eNodeB

LST VRET MOD VRET

VRET

CONNCN

Cabinet No.

eNodeB

LST VRET

VRET

CONNSRN

Subrack No.

eNodeB

LST VRET

VRET

CONNSN

Slot No.

eNodeB

LST VRET

VRET

DEVICENAME

Device Name

eNodeB

MOD VRET LST VRET

VRET

SUBUNITQUANTIT Subunit Quantity Y

eNodeB

MOD VRET LST VRET

VRETSubunit

CONNCN

Cabinet No.

eNodeB

None

VRETSubunit

CONNPN1

Connected Port 1

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

CONNPN2

Connected Port 2

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

SUBNAME

Device Name

eNodeB

MOD VRETSUBUNIT LST VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT MOD VRETSUBUNIT MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

DEVICENO

Device No.

eNodeB

VRETSubunit

POLARTYPE1

Polar Type1

eNodeB

VRETSubunit

CONNSN

Slot No.

eNodeB

None

VRETSubunit

CONNSRN

Subrack No.

eNodeB

None

VRETSubunit

SUBUNITNO

Subunit No.

eNodeB

DSP VRETSUBUNIT LST VRETSUBUNIT MOD VRETSUBUNIT

VRETSubunit

CONNPN3

Connected Port 3

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

POLARTYPE2

Polar Type2

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

DLTILT

Downlink Tilt

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

ULTILT

Uplink Tilt

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

CONNPN4

Connected Port 4

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

POLARTYPE3

Polar Type3

eNodeB

MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT MOD VRETSUBUNIT DSP VRETSUBUNIT LST VRETSUBUNIT

VRETSubunit

POLARTYPE4

Polar Type4

eNodeB

VRETSubunit

PORTNUM

PORTNUM

eNodeB

MOD VRETSUBUNIT ADD CTRLLNK LST CTRLLNK MOD CTRLLNK RMV CTRLLNK ADD CTRLLNK DSP CTRLLNKSTAT MOD CTRLLNK LST CTRLLNK ADD CTRLLNK DSP CTRLLNKSTAT MOD CTRLLNK LST CTRLLNK

CTRLLNK

LN

Local Link No.

eNodeB

CTRLLNK

CN

Local Cabinet No.

eNodeB

CTRLLNK

SRN

Local Subrack No.

eNodeB

CTRLLNK

SN

Local Slot No.

eNodeB

ADD CTRLLNK DSP CTRLLNKSTAT MOD CTRLLNK LST CTRLLNK ADD CTRLLNK MOD CTRLLNK LST CTRLLNK

CTRLLNK

UPCN

Upper Cabinet No.

eNodeB

CTRLLNK

UPSRN

Upper Subrack No. eNodeB

ADD CTRLLNK MOD CTRLLNK LST CTRLLNK

CTRLLNK

UPSN

Upper Slot No.

eNodeB

ADD CTRLLNK MOD CTRLLNK LST CTRLLNK

CTRLLNK

UPPT

Upper Port No.

eNodeB

ADD CTRLLNK MOD CTRLLNK LST CTRLLNK

CTRLLNK

PT

Port No.

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

TIMESTART

Measurement Start eNodeB Time

DSP CTRLLNKSTAT

CTRLLNK

ONEDAYERRPKG 1 Day Error NUM Package Number

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEDAYERRPKG 1 Day Error RATE Package Rate

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEDAYERRLOS RATE

1 Day LOS Rate

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEDAYERRLOST 1 Day LOS time IME

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEHOURERRPK 1 Hour Error GNUM Package Number

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEHOURERRPK 1 Hour Error GRATE Package Rate

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEHOURERRLO 1 Hour LOS Rate SRATE

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEHOURERRLO 1 Hour LOS Time STIME

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEWEEKERRPK 1 Week Error GNUM Package Number

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEWEEKERRPK 1 Week Error GRATE Package Rate

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEWEEKERRLO 1 Week LOS Rate SRATE

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

ONEWEEKERRLO 1 Week LOS time STIME

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

TOTALERRPKGNU Total Error Package eNodeB M Number

DSP CTRLLNKSTAT

CTRLLNK

TOTALLOSTIME

Total LOS Time

eNodeB

DSP CTRLLNKSTAT

CTRLLNK

TOTALTSTIME

Total Measurement eNodeB Time

DSP CTRLLNKSTAT

CTRLLNK

TOTALRXPKGNU M

Total Receive Package Number

eNodeB

DSP CTRLLNKSTAT

BITS

BN

BITS Clock No.

eNodeB

ADD BITS DSP BITS MOD BITS RMV BITS LST BITS

BITS

CN

Cabinet No.

eNodeB

ADD BITS LST BITS

BITS

SRN

Subrack No.

eNodeB

ADD BITS LST BITS

BITS

SN

Slot No.

eNodeB

ADD BITS LST BITS

BITS

ActiveState

Link Active State

eNodeB

DSP BITS

BITS

AvailableState

Link Available State eNodeB

DSP BITS

BITS

PRI

Priority

eNodeB

ADD BITS MOD BITS LST BITS

LineClk

LN

Line Clock No.

eNodeB

ADD LINECLK DSP LINECLK MOD LINECLK RMV LINECLK LST LINECLK

LineClk

CN

Cabinet No.

eNodeB

ADD LINECLK LST LINECLK

LineClk

SRN

Subrack No.

eNodeB

ADD LINECLK LST LINECLK

LineClk

SN

Slot No.

eNodeB

ADD LINECLK LST LINECLK

LineClk

PN

Port No.

eNodeB

ADD LINECLK DSP LINECLK LST LINECLK

LineClk

ActiveState

Link Active State

eNodeB

DSP LINECLK

LineClk

AvailableState

Link Available State eNodeB

DSP LINECLK

LineClk

PRI

Priority

eNodeB

ADD LINECLK MOD LINECLK LST LINECLK

PeerClk

PN

Peer Clock No.

eNodeB

ADD PEERCLK DSP PEERCLK RMV PEERCLK LST PEERCLK

PeerClk

PS

Peer Standard

eNodeB

ADD PEERCLK LST PEERCLK

PeerClk

ActiveState

Link Active State

eNodeB

DSP PEERCLK

PeerClk

AvailableState

Link Available State eNodeB

DSP PEERCLK

TOD

TN

TOD Clock No.

eNodeB

ADD TOD DSP TOD MOD TOD RMV TOD LST TOD

TOD

TYPE

TOD Type

eNodeB

ADD TOD DSP TOD LST TOD

TOD

CN

Cabinet No.

eNodeB

ADD TOD LST TOD

TOD

SRN

Subrack No.

eNodeB

ADD TOD LST TOD

TOD

SN

Slot No.

eNodeB

ADD TOD LST TOD

TOD

CABLETYPE

Cable Type

eNodeB

ADD TOD MOD TOD LST TOD

TOD

CABLE_LEN

Cable Length

eNodeB

ADD TOD MOD TOD LST TOD

TOD

ActiveState

Link Active State

eNodeB

DSP TOD

TOD

AvailableState

Link Available State eNodeB

DSP TOD

TOD

DELAY

Delay

eNodeB

DSP TOD

TOD

PRI

Priority

eNodeB

ADD TOD MOD TOD LST TOD

GPS

GN

GPS Clock No.

eNodeB

ADD GPS DSP GPS MOD GPS RMV GPS RST SATCARD LST GPS

GPS

CN

Cabinet No.

eNodeB

ADD GPS LST GPS

GPS

SRN

Subrack No.

eNodeB

ADD GPS LST GPS

GPS

SN

Slot No.

eNodeB

ADD GPS LST GPS

GPS

WPOS

Way to Get Position eNodeB

MOD GPSPOS LST GPSPOS

GPS

LONG

Antenna Longitude eNodeB

MOD GPSPOS DSP GPS LST GPSPOS

GPS

LAT

Antenna Latitude

eNodeB

MOD GPSPOS DSP GPS LST GPSPOS

GPS

ALT

Antenna Altitude

eNodeB

MOD GPSPOS DSP GPS LST GPSPOS

GPS

AGL

Antenna Angle

eNodeB

MOD GPSPOS DSP GPS LST GPSPOS

GPS

DELAY

Feeder Delay

eNodeB

DSP GPS

GPS

DURATION

Duration

eNodeB

MOD GPSPOS LST GPSPOS

GPS

PRECISION

Precision

eNodeB

MOD GPSPOS LST GPSPOS

GPS

CABLETYPE

Cable Type

eNodeB

ADD GPS MOD GPS LST GPS

GPS

CABLE_LEN

Cable Length

eNodeB

ADD GPS MOD GPS LST GPS

GPS

GpsVersion

GPS Version

eNodeB

DSP GPS

GPS

PosFix

GPS Position Fixed eNodeB

DSP GPS

GPS

Almnac

Almanac Validity

eNodeB

DSP GPS

GPS

PosSolu

Position Solution

eNodeB

DSP GPS

GPS

FixPos

Fixed Position

eNodeB

DSP GPS

GPS

ClkSteer

Clock Steering

eNodeB

DSP GPS

GPS

ClkMode

Clock Model Validity eNodeB

DSP GPS

GPS

GlonassNum

GLONASS Satellites Traced

eNodeB

DSP GPS

GPS

GpsCardState

GPS Card State

eNodeB

DSP GPS

GPS

GpsCardType

GPS Card Type

eNodeB

DSP GPS

GPS

GpsNum

GPS Satellites Traced

eNodeB

DSP GPS

GPS

MODE

GPS Work Mode

eNodeB

ADD GPS MOD GPS DSP GPS LST GPS

GPS

CompassNum

COMPASS Satellites Traced

eNodeB

DSP GPS

GPS

ActiveState

Link Active State

eNodeB

DSP GPS

GPS

PRI

Priority

eNodeB

ADD GPS MOD GPS LST GPS

IPCLKLNK

LN

IP Clock No.

eNodeB

ADD IPCLKLINK DSP IPCLKLINK DSP PRICLASS RMV IPCLKLINK SET CLASSIDENTIFY SET PRICLASS LST IPCLKLINK LST PRICLASS

IPCLKLNK

ICPT

Protocol Type

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

CN

Cabinet No.

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

SRN

Subrack No.

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

SN

Slot No.

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

CIP

Client IPv4

eNodeB

ADD IPCLKLINK DSP IPCLKLINK LST IPCLKLINK

IPCLKLNK

SIP

Server IPv4

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

DM

Domain

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

DELAYTYPE

Delay Type

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

CLASSIDENTIFY

Priority Clock Class eNodeB Identify Flag

SET CLASSIDENTIFY DSP PRICLASS

IPCLKLNK

CLASS0

Priority Clock Class0

eNodeB

SET PRICLASS DSP PRICLASS LST PRICLASS

IPCLKLNK

CLASS1

Priority Clock Class1

eNodeB

SET PRICLASS DSP PRICLASS LST PRICLASS

IPCLKLNK

CLASS2

Priority Clock Class2

eNodeB

SET PRICLASS DSP PRICLASS LST PRICLASS

IPCLKLNK

CLASS3

Priority Clock Class3

eNodeB

SET PRICLASS DSP PRICLASS LST PRICLASS

IPCLKLNK

CurClass

Current Priority Clock Class

eNodeB

DSP PRICLASS

IPCLKLNK

MACMODE

Clock Source Specified or Not

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

CLKMAC

Clock Source MAC eNodeB Address

ADD IPCLKLINK DSP IPCLKLINK LST IPCLKLINK

IPCLKLNK

ActiveState

Link Active State

eNodeB

DSP IPCLKLINK

IPCLKLNK

AvailableState

Link Available State eNodeB

DSP IPCLKLINK

IPCLKLNK

CNM

Clock Net Mode

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

CMPST

Compensation

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

StepMode

Step Mode

eNodeB

DSP IPCLKLINK

IPCLKLNK

VlanId

VLAN ID

eNodeB

DSP IPCLKLINK

IPCLKLNK

UtcOffset

UTC Offset

eNodeB

None

IPCLKLNK

PRI

Priority

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

ANNFREQ

Announce Freq

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

SYNCFREQ

Sync Freq

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

MASTERPRIO

Master Priority

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

PROFILETYPE

Profile Type

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

NEGDURATION

Negotiate Duration

eNodeB

ADD IPCLKLINK LST IPCLKLINK

IPCLKLNK

IPMODE

IP mode

eNodeB

ADD IPCLKLINK DSP IPCLKLINK LST IPCLKLINK

IPCLKLNK

CIPV6

Client IPv6

eNodeB

ADD IPCLKLINK DSP IPCLKLINK LST IPCLKLINK

IPCLKLNK

SIPV6

Server IPv6

eNodeB

ADD IPCLKLINK LST IPCLKLINK

SyncEth

LN

SyncEth Clock No.

eNodeB

ADD SYNCETH DSP SYNCETH MOD SYNCETH RMV SYNCETH LST SYNCETH

SyncEth

CN

Cabinet No.

eNodeB

ADD SYNCETH LST SYNCETH

SyncEth

SRN

Subrack No.

eNodeB

ADD SYNCETH LST SYNCETH

SyncEth

SN

Slot No.

eNodeB

ADD SYNCETH LST SYNCETH

SyncEth

PN

Port No.

eNodeB

ADD SYNCETH LST SYNCETH

SyncEth

SSM

SSM Selection

eNodeB

ADD SYNCETH MOD SYNCETH DSP SYNCETH LST SYNCETH

SyncEth

ActiveState

Link Active State

eNodeB

DSP SYNCETH

SyncEth

AvailableState

Link Available State eNodeB

DSP SYNCETH

SyncEth

PRI

Priority

eNodeB

ADD SYNCETH MOD SYNCETH LST SYNCETH

Tasm

AvailableState

Clock Source State eNodeB

DSP CLKSRC

Tasm

LicenseAuthorized

License Authorized eNodeB

DSP CLKSRC

Tasm

PRI

Clock Source Priority

eNodeB

DSP CLKSRC

Tasm

SRCNO

Clock Source No.

eNodeB

SET CLKMODE DSP CLKSRC LST CLKMODE

Tasm

CLKSRC

Selected Clock Source

eNodeB

SET CLKMODE LST CLKMODE

Tasm

MODE

Clock Working Mode

eNodeB

SET CLKMODE DSP CLKSTAT LST CLKMODE

Tasm

CLKSYNCMODE

Clock Synchronization Mode

eNodeB

SET CLKSYNCMODE DSP CLKSTAT LST CLKSYNCMODE

Tasm

CurrentSrcStatus

Current Clock Source State

eNodeB

DSP CLKSTAT

Tasm

PllStatus

PLL Status

eNodeB

DSP CLKRECORD DSP CLKSTAT DSP CLKTST

Tasm

CurrentSrc

Current Clock Source

eNodeB

DSP CLKSTAT

Tasm

CN

Cabinet No.

eNodeB

DSP CLKDA DSP CLKRECORD DSP CLKSTAT DSP CLKTHD DSP CLKTST DSP DARECORD DSP TSTCLKOUT MOD CENTERDA MOD CURRDA SET CLKTHD SET TSTCLKOUT STP CLKTST STR CLKTST DSP CLKDA DSP CLKRECORD DSP CLKSTAT DSP CLKTHD DSP CLKTST DSP DARECORD DSP TSTCLKOUT MOD CENTERDA MOD CURRDA SET CLKTHD SET TSTCLKOUT STP CLKTST STR CLKTST DSP CLKDA DSP CLKRECORD DSP CLKSTAT DSP CLKTHD DSP CLKTST DSP DARECORD DSP TSTCLKOUT MOD CENTERDA MOD CURRDA SET CLKTHD SET TSTCLKOUT STP CLKTST STR CLKTST

Tasm

SRN

Subrack No.

eNodeB

Tasm

SN

Slot No.

eNodeB

Tasm

QL

Quality Level

eNodeB

SET LOCALCLKQL DSP SYNCETH LST LOCALCLKQL

BBP

CN

Cabinet No.

eNodeB

LST BBP MOD BBP

BBP

SRN

Subrack No.

eNodeB

LST BBP MOD BBP

BBP

SN

Slot No.

eNodeB

LST BBP MOD BBP

BBP

TYPE

Board Type

eNodeB

None

BBP

WM

Work Mode

eNodeB

ADD BRD MOD BBP LST BBP

BBP

AdmState

Administrative state eNodeB

None

BBP

TIME

Duration of the eNodeB shutting down state

BLK BRD

BBP

BLKTP

Block Type

eNodeB

BLK BRD

BBP

AlarmState

Alarm Status

eNodeB

None

BBP

OpState

Operational State

eNodeB

None

BBP

AvailabilityStatus

Availability Status

eNodeB

None

BBP

Elabel

Electronic Label

eNodeB

None

BBP BBP

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

BBP

BoardDesc

Description

eNodeB

None

BBP

BoardManu

Date of Manufacture

eNodeB

None

BBP

BoardVendor

Vendor

eNodeB

None

BBP

BoardIssue

Issue Number

eNodeB

None

BBP

RuType

Board Type

eNodeB

None

BBP BBP

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

BBP

ObjectType

Object Type

eNodeB

None

BBP

BoardTemperature Board Temperature eNodeB

None

BBP BBP

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

BBP

ServiceType

Service Type

eNodeB

None

BBP

DEVTYPE

DEVTYPE

eNodeB

None

BBP BBP

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

BBP

HardVer

Hardware Version

eNodeB

None

BBP BBP

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

BBP

TestResult

Test Result

eNodeB

None

BBP

DLFREQ

Downlink Frequency

eNodeB

None

BBP

ULFREQ

Uplink Frequency

eNodeB

None

BbuFan

CN

Cabinet No.

eNodeB

DSP FAN

BbuFan

SRN

Subrack No.

eNodeB

DSP FAN

BbuFan

SN

Slot No.

eNodeB

DSP FAN

BbuFan

Temperature

Temperature

eNodeB

DSP FAN

BbuFan

SpeedRate

Fan Speed Rate

eNodeB

DSP FAN

BbuFan

AlarmState

Alarm Status

eNodeB

None

BbuFan

OpState

Operational State

eNodeB

None

BbuFan

AvailabilityStatus

Availability Status

eNodeB

None

BbuFan

Elabel

Electronic Label

eNodeB

None

BbuFan BbuFan

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

BbuFan

BoardDesc

Description

eNodeB

None

BbuFan

BoardManu

Date of Manufacture

eNodeB

None

BbuFan

BoardVendor

Vendor

eNodeB

None

BbuFan

BoardIssue

Issue Number

eNodeB

None

BbuFan

RuType

Board Type

eNodeB

None

BbuFan BbuFan

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

BbuFan

ObjectType

Object Type

eNodeB

None

BbuFan

BoardTemperature Board Temperature eNodeB

None

BbuFan BbuFan

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

BbuFan

ServiceType

Service Type

eNodeB

None

BbuFan

DEVTYPE

DEVTYPE

eNodeB

None

BbuFan BbuFan

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

BbuFan

HardVer

Hardware Version

eNodeB

None

BbuFan BbuFan

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

BbuFan

TestResult

Test Result

eNodeB

None

BbuFan

DLFREQ

Downlink Frequency

eNodeB

None

BbuFan

ULFREQ

Uplink Frequency

eNodeB

None

CCU

CN

Cabinet No.

eNodeB

ADD CCU CLR CCUALM DSP CCU LST CCU MOD CCU RMV CCU ADD CCU CLR CCUALM DSP CCU LST CCU MOD CCU RMV CCU ADD CCU CLR CCUALM DSP CCU LST CCU MOD CCU RMV CCU

CCU

SRN

Subrack No.

eNodeB

CCU

SN

Slot No.

eNodeB

CCU

MCN

Manager Cabinet No.

eNodeB

ADD CCU MOD CCU LST CCU ADD CCU MOD CCU LST CCU ADD CCU MOD CCU LST CCU ADD CCU MOD CCU LST CCU ADD CCU MOD CCU DSP CCU LST CCU ADD CCU MOD CCU LST CCU

CCU

MSRN

Manager Subrack No.

eNodeB

CCU

MPN

Manager Port No.

eNodeB

CCU

DCF

DirectConnectFlag

eNodeB

CCU

CCN

Cascade No.

eNodeB

CCU

CS

Connected Standard

eNodeB

CCU

SBAF

Special Boolean Alarm Flag

eNodeB

ADD CCU MOD CCU LST CCU

CCU

LPortStatus

Left Port Status

eNodeB

DSP CCU

CCU

RPortStatus

Right Port Status

eNodeB

DSP CCU

CCU CCU

SoftwareVersion PCBVersion

Software Version PCB Version

eNodeB eNodeB

DSP CCU DSP CCU

CCU

EPLDVersion

EPLD Version

eNodeB

DSP CCU

CPRILBR

RCN

RRU Chain No.

eNodeB

DSP CPRILBR STR CPRILBRNEG

CPRILBR

CURLBR

Current head line bit eNodeB rate

DSP CPRILBR

CPRILBR

CURNEGSTAT

Current head negotiation status

eNodeB

DSP CPRILBR

CPRILBR

CURTAILLBR

Current tail line bit rate

eNodeB

DSP CPRILBR

CPRILBR

CURNEGSTAT

Current tail negotiation status

eNodeB

DSP CPRILBR

CPRILBR CPRILBR CPRILBR

CN SRN SN

Cabinet No. Subrack No. Slot No.

eNodeB eNodeB eNodeB

DSP CPRILBR DSP CPRILBR DSP CPRILBR

CPRILBR

NODE

Node

eNodeB

DSP CPRILBR

CPRILBR

MAXBR

Max bit rate

eNodeB

DSP CPRILBR

CpriPort

CN

Cabinet No.

eNodeB

DSP CPRIPORT DSP RRUCHAINPHYTO PO

CpriPort

SRN

Subrack No.

eNodeB

DSP CPRIPORT DSP RRUCHAINPHYTO PO

CpriPort

SN

Slot No.

eNodeB

DSP CPRIPORT DSP RRUCHAINPHYTO PO

CpriPort

OPTN

Optical Port No.

eNodeB

DSP CPRIPORT DSP RRUCHAINPHYTO PO

CpriPort

CpriRate

CPRI Bit Rate

eNodeB

DSP CPRIPORT

CpriPort

AdmState

Block Status

eNodeB

DSP CPRIPORT

CpriPort

InstallStatus

Install Status

eNodeB

DSP CPRIPORT

CpriPort

CPRIPortMode

CPRI Port Mode

eNodeB

DSP CPRIPORT

CpriPort

PortType

Port Type

eNodeB

DSP CPRIPORT

CpriPort

BackupMode

Backup Mode

eNodeB

None

CpriPort

CMChannelType

CM Channel Type

eNodeB

None

CpriPort

DLBandWidth

DL Band Width

eNodeB

None

CpriPort

DLIQConsnum

DL IQ Consnum

eNodeB

None

CpriPort

ULIQConsnum

UL IQ Consnum

eNodeB

None

CpriPort

CpriMuxStatus

CPRI Port Mux Status

eNodeB

DSP CPRIPORT

ENERGYCON

MP

Energy Consumption eNodeB Measurement Point

SET ECMP LST ECMP

MPT

CN

Cabinet No.

eNodeB

None

MPT

SRN

Subrack No.

eNodeB

None

MPT

SN

Slot No.

eNodeB

None

MPT

TYPE

Board Type

eNodeB

None

MPT

StandbyStatus

StandBy Status

eNodeB

DSP BRD

MPT

AlarmState

Alarm Status

eNodeB

None

MPT

OpState

Operational State

eNodeB

None

MPT

AvailabilityStatus

Availability Status

eNodeB

None

MPT

Elabel

Electronic Label

eNodeB

None

MPT MPT

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

MPT

BoardDesc

Description

eNodeB

None

MPT

BoardManu

Date of Manufacture

eNodeB

None

MPT

BoardVendor

Vendor

eNodeB

None

MPT

BoardIssue

Issue Number

eNodeB

None

MPT

RuType

Board Type

eNodeB

None

MPT MPT

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

MPT

ObjectType

Object Type

eNodeB

None

MPT

BoardTemperature Board Temperature eNodeB

None

MPT MPT

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

MPT

ServiceType

Service Type

eNodeB

None

MPT

DEVTYPE

DEVTYPE

eNodeB

None

MPT MPT

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

MPT

HardVer

Hardware Version

eNodeB

None

MPT MPT

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

MPT

TestResult

Test Result

eNodeB

None

MPT

DLFREQ

Downlink Frequency

eNodeB

None

MPT

ULFREQ

Uplink Frequency

eNodeB

None

PEU

CN

Cabinet No.

eNodeB

DSP UPEU

PEU

SRN

Subrack No.

eNodeB

DSP UPEU

PEU

SN

Slot No.

eNodeB

DSP UPEU

PEU PEU

UpeuSparePower BbuSparePower

UPEU Spare Power eNodeB BBU Spare Power eNodeB

DSP UPEU DSP UPEU

PEU

AlarmState

Alarm Status

eNodeB

None

PEU

OpState

Operational State

eNodeB

None

PEU

AvailabilityStatus

Availability Status

eNodeB

None

PEU

Elabel

Electronic Label

eNodeB

None

PEU PEU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

PEU

BoardDesc

Description

eNodeB

None

PEU

BoardManu

Date of Manufacture

eNodeB

None

PEU

BoardVendor

Vendor

eNodeB

None

PEU

BoardIssue

Issue Number

eNodeB

None

PEU

RuType

Board Type

eNodeB

None

PEU PEU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

PEU

ObjectType

Object Type

eNodeB

None

PEU

BoardTemperature Board Temperature eNodeB

None

PEU PEU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

PEU

ServiceType

Service Type

eNodeB

None

PEU

DEVTYPE

DEVTYPE

eNodeB

None

PEU PEU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

PEU

HardVer

Hardware Version

eNodeB

None

PEU PEU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

PEU

TestResult

Test Result

eNodeB

None

PEU

DLFREQ

Downlink Frequency

eNodeB

None

PEU

ULFREQ

Uplink Frequency

eNodeB

None

PSUIS

PSUISS

PSU Intelligent Shutdown Switch

eNodeB

SET PSUISS LST PSUISS

SFP

CN

Cabinet No.

eNodeB

DSP SFP

SFP

SRN

Subrack No.

eNodeB

DSP SFP

SFP

SN

Slot No.

eNodeB

DSP SFP

SFP

MODULEID

SFP Module Number

eNodeB

DSP SFP

SFP

InstallStatus

Installed status

eNodeB

DSP SFP

SFP

OptType

SFP Module Type

eNodeB

DSP SFP

SFP

VendorName

Manufacturer name eNodeB

DSP SFP

SFP

TransMode

Transmission Mode eNodeB

DSP SFP

SFP

WaveLength

Wavelength

eNodeB

DSP SFP

SFP

Rating

Transmission code eNodeB rate

DSP SFP

SFP

LinkLength0

Transmission distance of singlemode fiber (9micrometer core diameter)

eNodeB

DSP SFP

SFP

LinkLength1

Transmission distance of singlemode fiber (9micrometer core diameter)

eNodeB

DSP SFP

SFP

LinkLength2

Transmission distance of multimode fiber (50micrometer core diameter)

eNodeB

DSP SFP

SFP

LinkLength3

Transmission distance of multimode fiber (62.5micrometer core diameter)

eNodeB

DSP SFP

SFP

Temperature

Temperature

eNodeB

DSP SFP

SFP

Voltage

Voltage

eNodeB

DSP SFP

SFP

Current

Current

eNodeB

DSP SFP

SFP

OutputPower

TX optical power

eNodeB

DSP SFP

SFP

InputPower

RX optical power

eNodeB

DSP SFP

SFP

Transmission CopperCableLength distance of copper cable

eNodeB

None DSP BRDRAT LST UTRP MOD UTRP SET BRDRAT DSP BRDRAT LST UTRP MOD UTRP SET BRDRAT DSP BRDRAT LST UTRP MOD UTRP SET BRDRAT

TRP

CN

Cabinet No.

eNodeB

TRP

SRN

Subrack No.

eNodeB

TRP

SN

Slot No.

eNodeB

TRP

SUBTYPE

SubBoard Type

eNodeB

MOD UTRP LST UTRP

TRP

StandbyStatus

Board Standby Status

eNodeB

None

TRP

AlarmState

Alarm Status

eNodeB

None

TRP

OpState

Operational State

eNodeB

None

TRP

AvailabilityStatus

Availability Status

eNodeB

None

TRP

Elabel

Electronic Label

eNodeB

None

TRP TRP

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

TRP

BoardDesc

Description

eNodeB

None

TRP

BoardManu

Date of Manufacture

eNodeB

None

TRP

BoardVendor

Vendor

eNodeB

None

TRP

BoardIssue

Issue Number

eNodeB

None

TRP

RuType

Board Type

eNodeB

None

TRP TRP

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

TRP

ObjectType

Object Type

eNodeB

None

TRP

BoardTemperature Board Temperature eNodeB

None

TRP TRP

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

TRP

ServiceType

Service Type

eNodeB

None

TRP

DEVTYPE

DEVTYPE

eNodeB

None

TRP TRP

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

TRP

HardVer

Hardware Version

eNodeB

None

TRP TRP

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

TRP

TestResult

Test Result

eNodeB

None

TRP

DLFREQ

Downlink Frequency

eNodeB

None

TRP

ULFREQ

Uplink Frequency

eNodeB

None

UCIU

CN

Cabinet No.

eNodeB

None

UCIU UCIU

SRN SN

Subrack No. Slot No.

eNodeB eNodeB

None None

UCIU

AlarmState

Alarm Status

eNodeB

None

UCIU

OpState

Operational State

eNodeB

None

UCIU

AvailabilityStatus

Availability Status

eNodeB

None

UCIU

Elabel

Electronic Label

eNodeB

None

UCIU UCIU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

UCIU

BoardDesc

Description

eNodeB

None

UCIU

BoardManu

Date of Manufacture

eNodeB

None

UCIU

BoardVendor

Vendor

eNodeB

None

UCIU

BoardIssue

Issue Number

eNodeB

None

UCIU

RuType

Board Type

eNodeB

None

UCIU UCIU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

UCIU

ObjectType

Object Type

eNodeB

None

UCIU

BoardTemperature Board Temperature eNodeB

None

UCIU UCIU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

UCIU

ServiceType

Service Type

eNodeB

None

UCIU

DEVTYPE

DEVTYPE

eNodeB

None

UCIU UCIU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

UCIU

HardVer

Hardware Version

eNodeB

None

UCIU UCIU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

UCIU

TestResult

Test Result

eNodeB

None

UCIU

DLFREQ

Downlink Frequency

eNodeB

None

UCIU

ULFREQ

Uplink Frequency

eNodeB

None

UEIU

CN

Cabinet No.

eNodeB

None

UEIU

SRN

Subrack No.

eNodeB

None

UEIU

SN

Slot No.

eNodeB

None

UEIU

AlarmState

Alarm Status

eNodeB

None

UEIU

OpState

Operational State

eNodeB

None

UEIU

AvailabilityStatus

Availability Status

eNodeB

None

UEIU

Elabel

Electronic Label

eNodeB

None

UEIU UEIU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

UEIU

BoardDesc

Description

eNodeB

None

UEIU

BoardManu

Date of Manufacture

eNodeB

None

UEIU

BoardVendor

Vendor

eNodeB

None

UEIU

BoardIssue

Issue Number

eNodeB

None

UEIU

RuType

Board Type

eNodeB

None

UEIU UEIU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

UEIU

ObjectType

Object Type

eNodeB

None

UEIU

BoardTemperature Board Temperature eNodeB

None

UEIU UEIU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

UEIU

ServiceType

Service Type

eNodeB

None

UEIU

DEVTYPE

DEVTYPE

eNodeB

None

UEIU UEIU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

UEIU

HardVer

Hardware Version

eNodeB

None

UEIU UEIU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

UEIU

TestResult

Test Result

eNodeB

None

UEIU

DLFREQ

Downlink Frequency

eNodeB

None

UEIU

ULFREQ

Uplink Frequency

eNodeB

None

USCU

CN

Cabinet No.

eNodeB

None

USCU

SRN

Subrack No.

eNodeB

None

USCU

SN

Slot No.

eNodeB

None

USCU

AlarmState

Alarm Status

eNodeB

None

USCU

OpState

Operational State

eNodeB

None

USCU

AvailabilityStatus

Availability Status

eNodeB

None

USCU

Elabel

Electronic Label

eNodeB

None

USCU USCU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

USCU

BoardDesc

Description

eNodeB

None

USCU

BoardManu

Date of Manufacture

eNodeB

None

USCU

BoardVendor

Vendor

eNodeB

None

USCU

BoardIssue

Issue Number

eNodeB

None

USCU

RuType

Board Type

eNodeB

None

USCU USCU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

USCU

ObjectType

Object Type

eNodeB

None

USCU

BoardTemperature Board Temperature eNodeB

None

USCU USCU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

USCU

ServiceType

Service Type

eNodeB

None

USCU

DEVTYPE

DEVTYPE

eNodeB

None

USCU USCU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

USCU

HardVer

Hardware Version

eNodeB

None

USCU USCU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

USCU

TestResult

Test Result

eNodeB

None

USCU

DLFREQ

Downlink Frequency

eNodeB

None

USCU

ULFREQ

Uplink Frequency

eNodeB

None

Equipment

DID

Deployment ID

eNodeB

SET EQUIPMENT LST EQUIPMENT

Equipment

BATIMS

Battery Intelligent Management Switch

eNodeB

SET EQUIPMENT LST EQUIPMENT

Equipment

PAE

Power Lose Redundancy Alarm eNodeB Enabled

SET EQUIPMENT LST EQUIPMENT

Equipment

MNTMode

Maintenance Mode eNodeB

SET MNTMODE LST MNTMODE

Equipment

ST

Start Time of Status eNodeB Setting

SET MNTMODE LST MNTMODE

Equipment

ET

End Time of Status eNodeB Setting

SET MNTMODE LST MNTMODE

Equipment

MMSetRemark

Maintenance Mode eNodeB Setting Remark

SET MNTMODE LST MNTMODE

Equipment

CurrMNTMode

Current eNodeB Maintenance Mode

DSP MNTMODE

Equipment

DVAS

Direct Voltage Alarm Switch

eNodeB

SET DVAS LST DVAS

Equipment

DVAH

Direct Voltage Alarm Occured Threshold

eNodeB

SET DVAS LST DVAS

Equipment

DVAL

Direct Voltage Alarm Restored Threshold

eNodeB

SET DVAS LST DVAS

Cabinet

CN

Cabinet No.

eNodeB

ADD CABINET DSP CABMFRINFO LST CABINET MOD CABINET RMV CABINET

Cabinet

TYPE

Cabinet Type

eNodeB

ADD CABINET MOD CABINET LST CABINET

Cabinet

DESC

Cabinet Description eNodeB

ADD CABINET MOD CABINET LST CABINET

Cabinet

CabinetType

Model

eNodeB

DSP CABMFRINFO

Subrack

CN

Cabinet No.

eNodeB

ADD SUBRACK LST SUBRACK MOD SUBRACK RMV SUBRACK

Subrack

SRN

Subrack No.

eNodeB

ADD SUBRACK LST SUBRACK MOD SUBRACK RMV SUBRACK

Subrack

TYPE

Subrack Type

eNodeB

ADD SUBRACK LST SUBRACK

Subrack

DESC

Subrack Description eNodeB

ADD SUBRACK MOD SUBRACK LST SUBRACK

Subrack

PWRTYPE

Power Type

eNodeB

None

RU

AlarmState

Alarm Status

eNodeB

DSP BRD

RU

OpState

Operational State

eNodeB

DSP BRD

RU

AvailabilityStatus

Availability Status

eNodeB

DSP BRD

RU

Elabel

Electronic Label

eNodeB

DSP ELABEL

RU

BoardType

Type

eNodeB

RU

BoardSerial

Serial Number

eNodeB

DSP BRDMFRINFO DSP BRDMFRINFO DSP CABMFRINFO DSP HWTSTRESULT

RU

BoardDesc

Description

eNodeB

DSP BRDMFRINFO DSP CABMFRINFO DSP HWTSTRESULT DSP BRDMFRINFO DSP CABMFRINFO DSP BRDMFRINFO DSP CABMFRINFO DSP BRDMFRINFO

RU

BoardManu

Date of Manufacture

eNodeB

RU

BoardVendor

Vendor

eNodeB

RU

BoardIssue

Issue Number

eNodeB

RU

RuType

Board Type

eNodeB

DSP BRD

RU RU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

DSP CPUUSAGE DSP CPUUSAGE

RU

ObjectType

Object Type

eNodeB

DSP CPUUSAGE

RU

BoardTemperature Board Temperature eNodeB

DSP BRDTEMP

RU RU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

DSP BRDTEMP None

RU

ServiceType

Service Type

eNodeB

None

RU

DEVTYPE

DEVTYPE

eNodeB

DSP ELABEL

RU RU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

DSP HWTSTRESULT DSP HWTSTRESULT DSP HWTSTRESULT DSP HWTSTRESULT DSP HWTSTRESULT DSP HWTSTRESULT

RU

HardVer

Hardware Version

eNodeB

RU RU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

RU

TestResult

Test Result

eNodeB

RU

DLFREQ

Downlink Frequency

eNodeB

STR HWTST

RU

ULFREQ

Uplink Frequency

eNodeB

STR HWTST

EMU

CN

Cabinet No.

eNodeB

ADD EMU CLR EMUALM DSP EMU LST EMU MOD EMU RMV EMU ADD EMU CLR EMUALM DSP EMU LST EMU MOD EMU RMV EMU ADD EMU CLR EMUALM DSP EMU LST EMU MOD EMU RMV EMU

EMU

SRN

Subrack No.

eNodeB

EMU

SN

Slot No.

eNodeB

EMU

MCN

Manager Cabinet No.

eNodeB

ADD EMU LST EMU

EMU

MSRN

Manager Subrack No.

eNodeB

ADD EMU LST EMU

EMU

MPN

Manager Port No.

eNodeB

ADD EMU MOD EMU LST EMU

EMU

ADDR

Address

eNodeB

ADD EMU MOD EMU LST EMU

EMU

TLTHD

Temperature Alarm eNodeB Lower Threshold

ADD EMU MOD EMU LST EMU

EMU

TUTHD

Temperature Alarm eNodeB Upper Threshold

ADD EMU MOD EMU LST EMU

EMU

HLTHD

Humidity Alarm Lower Threshold

eNodeB

ADD EMU MOD EMU LST EMU

EMU

HUTHD

Humidity Alarm Upper Threshold

eNodeB

ADD EMU MOD EMU LST EMU

EMU

SAAF

Special Analog Alarm Flag

eNodeB

ADD EMU MOD EMU LST EMU

EMU

SBAF

Special Boolean Alarm Flag

eNodeB

ADD EMU MOD EMU LST EMU

EMU EMU

Temperature Humidity

Ambient Temperature Ambient Humidity

eNodeB eNodeB

DSP EMU DSP EMU

EMU

Invol48

-48V Input Voltage

eNodeB

DSP EMU

EMU

Anain1

Analog Port 1 eNodeB Measurement Value

DSP EMU

EMU

Anain2

Analog Port 2 eNodeB Measurement Value

DSP EMU

EMU

Anain3

Analog Port 3 eNodeB Measurement Value

DSP EMU

EMU

Anain4

Analog Port 4 eNodeB Measurement Value

DSP EMU

EMU

AlarmState

Alarm Status

eNodeB

None

EMU

OpState

Operational State

eNodeB

None

EMU

AvailabilityStatus

Availability Status

eNodeB

None

EMU

Elabel

Electronic Label

eNodeB

None

EMU EMU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

EMU

BoardDesc

Description

eNodeB

None

EMU

BoardManu

Date of Manufacture

eNodeB

None

EMU

BoardVendor

Vendor

eNodeB

None

EMU

BoardIssue

Issue Number

eNodeB

None

EMU

RuType

Board Type

eNodeB

None

EMU EMU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

EMU

ObjectType

Object Type

eNodeB

None

EMU

BoardTemperature Board Temperature eNodeB

None

EMU EMU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

EMU

ServiceType

Service Type

eNodeB

None

EMU

DEVTYPE

DEVTYPE

eNodeB

None

EMU EMU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

EMU

HardVer

Hardware Version

eNodeB

None

EMU EMU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

EMU

TestResult

Test Result

eNodeB

None

EMU

DLFREQ

Downlink Frequency

eNodeB

None

EMU

ULFREQ

Uplink Frequency

eNodeB

None

FMU

CN

Cabinet No.

eNodeB

ADD FMU CLR FMUALM DSP FMU LST FMU MOD FMU RMV FMU ADD FMU CLR FMUALM DSP FMU LST FMU MOD FMU RMV FMU ADD FMU CLR FMUALM DSP FMU LST FMU MOD FMU RMV FMU

FMU

SRN

Subrack No.

eNodeB

FMU

SN

Slot No.

eNodeB

FMU

MCN

Manager Cabinet No.

eNodeB

ADD FMU MOD FMU LST FMU

FMU

MSRN

Manager Subrack No.

eNodeB

ADD FMU MOD FMU LST FMU

FMU

MPN

Manager Port No.

eNodeB

ADD FMU MOD FMU LST FMU

FMU

ADDR

Address

eNodeB

ADD FMU MOD FMU LST FMU

FMU

SBAF

Special Boolean Alarm Flag

eNodeB

ADD FMU MOD FMU LST FMU

FMU

SpeedRate

Fan Speed Rate

eNodeB

DSP FMU

FMU

TempOut

Temperature at Fan eNodeB Air Outlet Temperature at Fan eNodeB Air Inlet

DSP FMU

FMU

TempIn

DSP FMU

FMU

AverageSpeed

Fan Average Speed eNodeB

DSP FMU

FMU

STC

Smart Temperature eNodeB Control

ADD FMU MOD FMU LST FMU

FMU

AlarmState

Alarm Status

eNodeB

None

FMU

OpState

Operational State

eNodeB

None

FMU

AvailabilityStatus

Availability Status

eNodeB

None

FMU

Elabel

Electronic Label

eNodeB

None

FMU FMU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

FMU

BoardDesc

Description

eNodeB

None

FMU

BoardManu

Date of Manufacture

eNodeB

None

FMU

BoardVendor

Vendor

eNodeB

None

FMU

BoardIssue

Issue Number

eNodeB

None

FMU

RuType

Board Type

eNodeB

None

FMU FMU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

FMU

ObjectType

Object Type

eNodeB

None

FMU

BoardTemperature Board Temperature eNodeB

None

FMU FMU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

FMU

ServiceType

Service Type

eNodeB

None

FMU

DEVTYPE

DEVTYPE

eNodeB

None

FMU FMU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

FMU

HardVer

Hardware Version

eNodeB

None

FMU FMU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

FMU

TestResult

Test Result

eNodeB

None

FMU

DLFREQ

Downlink Frequency

eNodeB

None

FMU

ULFREQ

Uplink Frequency

eNodeB

None

TCU

CN

Cabinet No.

eNodeB

ADD TCU CLR TCUALM DSP TCU LST TCU MOD TCU RMV TCU ADD TCU CLR TCUALM DSP TCU LST TCU MOD TCU RMV TCU

TCU

SRN

Subrack No.

eNodeB

TCU

SN

Slot No.

eNodeB

ADD TCU CLR TCUALM DSP TCU LST TCU MOD TCU RMV TCU

TCU

MCN

Manager Cabinet No.

eNodeB

ADD TCU LST TCU

TCU

MSRN

Manager Subrack No.

eNodeB

ADD TCU LST TCU

TCU

MPN

Manager Port No.

eNodeB

ADD TCU MOD TCU LST TCU

TCU

ADDR

Address

eNodeB

ADD TCU MOD TCU LST TCU

TCU

TLTHD

Temperature Alarm eNodeB Lower Threshold

ADD TCU MOD TCU LST TCU

TCU

TUTHD

Temperature Alarm eNodeB Upper Threshold

ADD TCU MOD TCU LST TCU

TCU

SBAF

Special Boolean Alarm Flag

eNodeB

ADD TCU MOD TCU LST TCU

TCU TCU

DeviceType TempIn

Device Type Temperature In

eNodeB eNodeB

DSP TCU DSP TCU

TCU

TempOut

Temperature Out

eNodeB

DSP TCU

TCU

TempInner

Temperature Inner

eNodeB

DSP TCU

TCU

InCycleSpeedRate

Inner Cycle Fan Average Speed

eNodeB

DSP TCU

TCU

OutCycleSpeedRat Outer Cycle Fan e Average Speed

eNodeB

DSP TCU

TCU

Power

Power

eNodeB

DSP TCU

TCU TCU

SoftwareVersion PCBVersion

Software Version PCB Version

eNodeB eNodeB

DSP TCU DSP TCU

TCU

EPLDVersion

EPLD Version

eNodeB

DSP TCU

TCU

SoftwareBuildTime Software Build Time eNodeB

DSP TCU

TCU

VersionDescription Version Description eNodeB

DSP TCU

TCU

ProduceDate

Produce Date

eNodeB

None

TCU

Manufacturer

Manufacturer

eNodeB

DSP TCU

TCU

AlarmState

Alarm Status

eNodeB

None

TCU

OpState

Operational State

eNodeB

None

TCU

AvailabilityStatus

Availability Status

eNodeB

None

TCU

Elabel

Electronic Label

eNodeB

None

TCU TCU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

TCU

BoardDesc

Description

eNodeB

None

TCU

BoardManu

Date of Manufacture

eNodeB

None

TCU

BoardVendor

Vendor

eNodeB

None

TCU

BoardIssue

Issue Number

eNodeB

None

TCU

RuType

Board Type

eNodeB

None

TCU TCU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

TCU

ObjectType

Object Type

eNodeB

None

TCU

BoardTemperature Board Temperature eNodeB

None

TCU TCU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

TCU

ServiceType

Service Type

eNodeB

None

TCU

DEVTYPE

DEVTYPE

eNodeB

None

TCU TCU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

TCU

HardVer

Hardware Version

eNodeB

None

TCU TCU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

TCU

TestResult

Test Result

eNodeB

None

TCU

DLFREQ

Downlink Frequency

eNodeB

None

TCU

ULFREQ

Uplink Frequency

eNodeB

None

HtCDPa

CN

Cabinet No.

eNodeB

LST HTCDPA MOD HTCDPA

HtCDPa

SRN

Subrack No.

eNodeB

LST HTCDPA MOD HTCDPA

HtCDPa

SN

Slot No.

eNodeB

LST HTCDPA MOD HTCDPA

HtCDPa

LTCP

Low Temperature Critical Point

eNodeB

MOD HTCDPA LST HTCDPA

HtCDPa

HTCP

High Temperature Critical Point

eNodeB

MOD HTCDPA LST HTCDPA

HtCDPa

TLT

Temperature Limit at Air Outlet

eNodeB

MOD HTCDPA LST HTCDPA

HtCDPa

DBD

Dead Band

eNodeB

MOD HTCDPA LST HTCDPA

HtCDPa

NTDI

Normal Temperature Delta Tin

eNodeB

MOD HTCDPA LST HTCDPA

HtCDPa

NTDO

Normal Temperature Delta Tout

eNodeB

MOD HTCDPA LST HTCDPA

HtCDPa

HTDO

High Temperature Delta Tout

eNodeB

MOD HTCDPA LST HTCDPA

PMU

CN

Cabinet No.

eNodeB

ADD PMU CLR PMUALM DSP PMU LST PMU MOD PMU RMV PMU ADD PMU CLR PMUALM DSP PMU LST PMU MOD PMU RMV PMU ADD PMU CLR PMUALM DSP PMU LST PMU MOD PMU RMV PMU

PMU

SRN

Subrack No.

eNodeB

PMU

SN

Slot No.

eNodeB

PMU

MCN

Manager Cabinet No.

eNodeB

ADD PMU LST PMU

PMU

MSRN

Manager Subrack No.

eNodeB

ADD PMU LST PMU

PMU

MPN

Manager Port No.

eNodeB

ADD PMU MOD PMU LST PMU

PMU

ADDR

Address

eNodeB

ADD PMU MOD PMU LST PMU

PMU

PTYPE

Power System Type eNodeB

ADD PMU MOD PMU LST PMU

PMU

ACVLTHD

AC Voltage Alarm Lower Threshold

eNodeB

ADD PMU MOD PMU LST PMU

PMU

ACVUTHD

AC Voltage Alarm Upper Threshold

eNodeB

ADD PMU MOD PMU LST PMU

PMU

DCVLTHD

DC Voltage Alarm Lower Threshold

eNodeB

ADD PMU MOD PMU LST PMU

PMU

DCVUTHD

DC Voltage Alarm Upper Threshold

eNodeB

ADD PMU MOD PMU LST PMU

PMU

LSDF

Load Shutdown Flag

eNodeB

ADD PMU MOD PMU LST PMU

PMU

LSDV

Load Shutdown Voltage

eNodeB

ADD PMU MOD PMU LST PMU

PMU

ATLTHD

Cabinet Temperature Alarm eNodeB Lower Threshold

ADD PMU MOD PMU LST PMU

PMU

ATUTHD

Cabinet Temperature Alarm eNodeB Upper Threshold

ADD PMU MOD PMU LST PMU

PMU

AHLTHD

Cabinet Humidity Alarm Lower Threshold

eNodeB

ADD PMU MOD PMU LST PMU

PMU

AHUTHD

Cabinet Humidity Alarm Upper Threshold

eNodeB

ADD PMU MOD PMU LST PMU

PMU

SAAF

Special Analog Alarm Flag

eNodeB

ADD PMU MOD PMU LST PMU

PMU

SBAF

Special Boolean Alarm Flag

eNodeB

ADD PMU MOD PMU LST PMU

PMU

AcVol

AC Voltage

eNodeB

DSP PMU

PMU PMU

DcVol LoadCurrent

Busbar Voltage Load Total Current

eNodeB eNodeB

DSP PMU DSP PMU

PMU

LoadTemp

Temperature

eNodeB

DSP PMU

PMU

Humidity

Cabinet Humidity

eNodeB

DSP PMU

PMU

ScdLoadPwrState

Secondary Load Power State

eNodeB

DSP PMU

PMU

BatChargeState

Charging/Dischargi eNodeB ng State

DSP BATTERY

PMU

BatCurrent

Battery Current

eNodeB

DSP BATTERY

PMU

BatCurrentLimitStat Current Limiting e State

eNodeB

None

PMU

BatPowerState

Battery Power State eNodeB

DSP BATTERY

PMU

BatRemainCapacity Remaining Capacity eNodeB

DSP BATTERY

PMU

BatTemp

Battery Temperature

eNodeB

DSP BATTERY

PMU

BatTestPhase

Battery Test Phase eNodeB

DSP BATTERY

PMU

PhotovoltaicArrayC Photovoltaic Array urrent Total Current

eNodeB

DSP PMU

PMU

DieselCurrent

Diesel Generator Current

eNodeB

DSP PMU

PMU

Auxiliary Battery AuxBatCabinetTem Cabinet p Temperature

eNodeB

DSP PMU

PMU PMU

SoftwareVersion PCBVersion

Software Version PCB Version

eNodeB eNodeB

DSP PMU DSP PMU

PMU

EPLDVersion

EPLD Version

eNodeB

DSP PMU

PMU

SoftwareBuildTime Software Build Time eNodeB

DSP PMU

PMU

VersionDescription Version Description eNodeB

DSP PMU

PMU

ProduceDate

Produce Date

eNodeB

DSP PMU

PMU

Manufacturer

Manufacturer

eNodeB

DSP PMU

PMU

ISCapability

PSU Intelligent Shutdown Capability

eNodeB

DSP PMU

PMU

ISSwitchState

PSU Intelligent Shutdown Switch

eNodeB

DSP PMU

PMU

ISExecuteResult

Execute Result

eNodeB

None

PMU

BatRemainTime

Remaining Time

eNodeB

DSP BATTERY

PMU

Battery BatAccumulatedCh Accumulated argeTime Charge Time

eNodeB

DSP BATTERY

PMU

Battery BatAccumulatedSle Accumulated epingTime Sleeping Time

eNodeB

DSP BATTERY

PMU

BatImsCapability

Battery Intelligent Management Capability

eNodeB

DSP PMU

PMU

BatImsSwitchState

Battery Intelligent eNodeB Management Mode

DSP PMU

PMU

AlarmState

Alarm Status

eNodeB

None

PMU

OpState

Operational State

eNodeB

None

PMU

AvailabilityStatus

Availability Status

eNodeB

None

PMU

Elabel

Electronic Label

eNodeB

None

PMU PMU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

PMU

BoardDesc

Description

eNodeB

None

PMU

BoardManu

Date of Manufacture

eNodeB

None

PMU

BoardVendor

Vendor

eNodeB

None

PMU

BoardIssue

Issue Number

eNodeB

None

PMU

RuType

Board Type

eNodeB

None

PMU PMU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

PMU

ObjectType

Object Type

eNodeB

None

PMU

BoardTemperature Board Temperature eNodeB

None

PMU PMU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

PMU

ServiceType

Service Type

eNodeB

None

PMU

DEVTYPE

DEVTYPE

eNodeB

None

PMU PMU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

PMU

HardVer

Hardware Version

eNodeB

None

PMU PMU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

PMU

TestResult

Test Result

eNodeB

None

PMU

DLFREQ

Downlink Frequency

eNodeB

None

PMU

ULFREQ

Uplink Frequency

eNodeB

None

DieselGen

CN

Cabinet No.

eNodeB

ADD DIESELGEN DSP DIESELGEN LST DIESELGEN MOD DIESELGEN RMV DIESELGEN STP DIESELGENTST STR DIESELGENTST ADD DIESELGEN DSP DIESELGEN LST DIESELGEN MOD DIESELGEN RMV DIESELGEN STP DIESELGENTST STR DIESELGENTST

DieselGen

SRN

Subrack No.

eNodeB

DieselGen

SN

Slot No.

eNodeB

ADD DIESELGEN DSP DIESELGEN LST DIESELGEN MOD DIESELGEN RMV DIESELGEN STP DIESELGENTST STR DIESELGENTST

DieselGen

ICF

Intelligent Control Flag

eNodeB

ADD DIESELGEN MOD DIESELGEN LST DIESELGEN

DieselGen

POWER

Rated Power

eNodeB

ADD DIESELGEN MOD DIESELGEN LST DIESELGEN

DieselGen

OL

Oil Level Diesel Generator Current

eNodeB

DSP DIESELGEN

DieselGen

DGC

eNodeB

DSP DIESELGEN

DieselGen

TRT

Total Running Time eNodeB

DSP DIESELGEN ADD BATTERY DSP BATINDT DSP BATTERY LST BATTERY MOD BATINDT MOD BATTERY RMV BATTERY

Battery

CN

Cabinet No.

eNodeB

Battery

SRN

Subrack No.

eNodeB

ADD BATTERY DSP BATINDT DSP BATTERY LST BATTERY MOD BATINDT MOD BATTERY RMV BATTERY ADD BATTERY DSP BATINDT DSP BATTERY LST BATTERY MOD BATINDT MOD BATTERY RMV BATTERY

Battery

SN

Slot No.

eNodeB

Battery

INSTALLTYPE

Installation Type

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

BCD

Boost-Charging Duration

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

BCV

Boost-Charging Voltage

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

BC1

Battery 1 Capacity

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

BCLC

Battery Current eNodeB Limiting Coefficient

ADD BATTERY MOD BATTERY LST BATTERY

Battery

FCV

Float-Charging Voltage

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

HTSDF

High Temperature Shutdown Flag

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

SDT

Shutdown Temperature

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

LVSDF

Low Voltage Shutdown Flag

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

SDV

Shutdown Voltage

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

TCC

Temperature Compensation Coefficient

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

Battery

TLTHD

Temperature Alarm eNodeB Lower Threshold

ADD BATTERY MOD BATTERY LST BATTERY

Battery

TUTHD

Temperature Alarm eNodeB Upper Threshold

ADD BATTERY MOD BATTERY LST BATTERY

Battery

BN

Battery Number

eNodeB

ADD BATTERY MOD BATTERY DSP BATTERY LST BATTERY

Battery

BTYPE

Battery Type

eNodeB

ADD BATTERY MOD BATTERY DSP BATTERY LST BATTERY

Battery

PCT

Power Cut Times

eNodeB

DSP BATTERY

Battery

CTHALF

Charge Times In Half an Hour

eNodeB

DSP BATTERY

Battery

CT1H

Charge Times In 1 Hour

eNodeB

DSP BATTERY

Battery

CT2H

Charge Times In 2 Hours

eNodeB

DSP BATTERY

Battery

CT3H

Charge Times In 3 Hours

eNodeB

DSP BATTERY

Battery

CT4H

Charge Times In 4 Hours

eNodeB

DSP BATTERY

Battery

CT5H

Charge Times In 5 Hours

eNodeB

DSP BATTERY

Battery

CT6H

Charge Times In 6 Hours

eNodeB

DSP BATTERY

Battery

CT7H

Charge Times In 7 Hours

eNodeB

DSP BATTERY

Battery

CT8H

Charge Times In 8 Hours

eNodeB

DSP BATTERY

Battery

CT8UH

Charge Times In More than 8 Hours

eNodeB

DSP BATTERY

Battery

DCTHALF

Discharge Times In eNodeB Half an Hour

DSP BATTERY

Battery

DCT1

Discharge Times In eNodeB 1 Hour

DSP BATTERY

Battery

DCT2

Discharge Times In eNodeB 2 Hours

DSP BATTERY

Battery

DCT3

Discharge Times In eNodeB 3 Hours

DSP BATTERY

Battery

DCT4

Discharge Times In eNodeB 4 Hours

DSP BATTERY

Battery

DCT5

Discharge Times In eNodeB 5 Hours

DSP BATTERY

Battery

DCT6

Discharge Times In eNodeB 6 Hours

DSP BATTERY

Battery

DCT7

Discharge Times In eNodeB 7 Hours

DSP BATTERY

Battery

DCT8

Discharge Times In eNodeB 8 Hours

DSP BATTERY

Battery

DCTU8

Discharge Times In eNodeB More than 8 Hours

DSP BATTERY

Battery

DATE

Installation Date

eNodeB

MOD BATINDT DSP BATINDT

Battery

BC2

Battery 2 Capacity

eNodeB

ADD BATTERY MOD BATTERY LST BATTERY

BatCTPa

CN

Cabinet No.

eNodeB

DSP BATTR LST BATCTPA MOD BATCTPA STP BATTST STR BATTST DSP BATTR LST BATCTPA MOD BATCTPA STP BATTST STR BATTST DSP BATTR LST BATCTPA MOD BATCTPA STP BATTST STR BATTST

BatCTPa

SRN

Subrack No.

eNodeB

BatCTPa

SN

Slot No.

eNodeB

BatCTPa

DSCHGT0

0.05C10 Discharge eNodeB Time

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT1

0.1C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT2

0.2C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT3

0.3C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT4

0.4C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT5

0.5C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT6

0.6C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT7

0.7C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT8

0.8C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSCHGT9

0.9C10 Discharge Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

EFF

Battery Charge Efficiency

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

ENDV

Discharge Test End eNodeB Voltage

MOD BATCTPA LST BATCTPA

BatCTPa

BATNUM

Battery Number

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DSTML

Discharge Test Time Limit

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

SDSTML

Simple Discharge Test Time Limit

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

SDSEV

Simple Discharge Test End Voltage

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

ATMODE

Automatic Test Mode

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

TDSTM

Timing Discharge Test Time

eNodeB

MOD BATCTPA LST BATCTPA

BatCTPa

DDSTM

Delayed Discharge eNodeB Test Time

MOD BATCTPA LST BATCTPA

BatCTPa

TYPE

Battery Test Type

eNodeB

STR BATTST DSP BATTR

BatCTPa

TstStrDateTime

Test Start Time

eNodeB

DSP BATTR

BatCTPa

TstEndReason

Test End Cause

eNodeB

DSP BATTR

BatCTPa

TstResult

Test Result

eNodeB

DSP BATTR

BatCTPa

TstEffi

Battery Efficency

eNodeB

DSP BATTR

BatCTPa

TstDischrLstTime

Discharge Last Time

eNodeB

DSP BATTR

BatCTPa

TstDischrEndVol

Discharge End Voltage

eNodeB

DSP BATTR

BatCTPa

TstDischrCurr

Discharge Average eNodeB Current

DSP BATTR

BatCTPa

TstDischrAh

Discharge AH

eNodeB

DSP BATTR

BatCTPa

TstBatTemp

Battery Temperature

eNodeB

DSP BATTR ADD PSU DSP PSU LST PSU RMV PSU ADD PSU DSP PSU LST PSU RMV PSU

PSU

CN

Cabinet No.

eNodeB

PSU

SRN

Subrack No.

eNodeB

PSU

SN

Slot No.

eNodeB

ADD PSU DSP PSU LST PSU RMV PSU

PSU

RunningStatus

Running Status

eNodeB

DSP PSU

PSU

ProduceDate

Produce Date

eNodeB

DSP PSU

PSU

Manufacturer

Manufacturer

eNodeB

DSP PSU

PSU

PCBVersion

PCB Version

eNodeB

DSP PSU

PSU

EPLDVersion

EPLD Version

eNodeB

DSP PSU

PSU

SoftwareBuildTime Software Build Time eNodeB

DSP PSU

PSU

AlarmState

Alarm Status

eNodeB

None

PSU

OpState

Operational State

eNodeB

None

PSU

AvailabilityStatus

Availability Status

eNodeB

None

PSU

Elabel

Electronic Label

eNodeB

None

PSU PSU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

PSU

BoardDesc

Description

eNodeB

None

PSU

BoardManu

Date of Manufacture

eNodeB

None

PSU

BoardVendor

Vendor

eNodeB

None

PSU

BoardIssue

Issue Number

eNodeB

None

PSU

RuType

Board Type

eNodeB

None

PSU PSU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

PSU

ObjectType

Object Type

eNodeB

None

PSU

BoardTemperature Board Temperature eNodeB

None

PSU PSU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

PSU

ServiceType

Service Type

eNodeB

None

PSU

DEVTYPE

DEVTYPE

eNodeB

None

PSU PSU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None DSP PSU

PSU

HardVer

Hardware Version

eNodeB

None

PSU PSU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

PSU

TestResult

Test Result

eNodeB

None

PSU

DLFREQ

Downlink Frequency

eNodeB

None

PSU

ULFREQ

Uplink Frequency

eNodeB

None

OutPort

CN

Cabinet No.

eNodeB

LST OUTPORT SET OUTPORT

OutPort

SRN

Subrack No.

eNodeB

LST OUTPORT SET OUTPORT

OutPort

SN

Slot No.

eNodeB

LST OUTPORT SET OUTPORT LST OUTPORT SET OUTPORT SET OUTPORT LST OUTPORT

OutPort

PN

Port No.

eNodeB

OutPort

NAME

Port Name

eNodeB

OutPort

SW

Port Switch

eNodeB

SET OUTPORT LST OUTPORT

AlmPort

CN

Cabinet No.

eNodeB

LST ALMPORT SET ALMPORT

AlmPort

SRN

Subrack No.

eNodeB

LST ALMPORT SET ALMPORT

AlmPort

SN

Slot No.

eNodeB

LST ALMPORT SET ALMPORT LST ALMPORT SET ALMPORT

AlmPort

PN

Port No.

eNodeB

AlmPort

SW

Switch

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

AID

Alarm ID

eNodeB

LST ALMPORT SET ALMPORT

AlmPort

PT

Port Type

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

AVOL

Alarm Voltage

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

UL

Alarm Upper Limit

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

LL

Alarm Lower Limit

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

ST

Sensor Type

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

SMUL

Sensor Measurement Upper Limit

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

SMLL

Sensor Measurement Lower Limit

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

SOUL

Sensor Output Upper Limit

eNodeB

SET ALMPORT LST ALMPORT

AlmPort

SOLL

Sensor Output Lower Limit

eNodeB

SET ALMPORT LST ALMPORT

SSL

CONNTYPE

Connection Type

eNodeB

SET CONNTYPE LST SSLCONF SET SSLAUTHMODE LST SSLCONF

SSL

AUTHMODE

Authentication Mode

eNodeB

AAU

CN

Cabinet No.

eNodeB

None

AAU

SRN

Subrack No.

eNodeB

None

AAU

SN

Slot No.

eNodeB

None

AAU

RN

RRU Name

eNodeB

None

AAU

RT

RRU Type

eNodeB

None

AAU

AdmState

Administrative state eNodeB

None

AAU

AlarmState

Alarm Status

eNodeB

None

AAU

OpState

Operational State

eNodeB

None

AAU

AvailabilityStatus

Availability Status

eNodeB

None

AAU

Elabel

Electronic Label

eNodeB

None

AAU AAU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

AAU

BoardDesc

Description

eNodeB

None

AAU

BoardManu

Date of Manufacture

eNodeB

None

AAU

BoardVendor

Vendor

eNodeB

None

AAU

BoardIssue

Issue Number

eNodeB

None

AAU

RuType

Board Type

eNodeB

None

AAU AAU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

AAU

ObjectType

Object Type

eNodeB

None

AAU

BoardTemperature Board Temperature eNodeB

None

AAU AAU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

AAU

ServiceType

Service Type

eNodeB

None

AAU

DEVTYPE

DEVTYPE

eNodeB

None

AAU

ALMPROCSW

VSWR alarm postprocessing switch

eNodeB

None

AAU

ALMPROCTHRHL D

VSWR alarm postprocessing threshold

eNodeB

None

AAU

ALMTHRHLD

VSWR alarm threshold

eNodeB

None

AAU

PS

RRU Position

eNodeB

None

AAU

RCN

RRU Chain No.

eNodeB

None

AAU

TP

RRU Topo Position eNodeB

None

AAU

RS

RRU Work Standard

eNodeB

None

AAU

RXNUM

Number of RX channels

eNodeB

None

AAU

TXNUM

Number of TX channels

eNodeB

None

AAU

CarrierNumPerRxBr Number of carriers anch on the RX channel CarrierNumPerTxBr Number of carriers anch on the TX channel

eNodeB

None

AAU

eNodeB

None

AAU

RxMinFreq

Minimum UL frequency

eNodeB

None

AAU

RxMaxFreq

Maximum UL frequency

eNodeB

None

AAU

TxMinFreq

Minimum DL frequency

eNodeB

None

AAU

TxMaxFreq

Maximum DL frequency

eNodeB

None

AAU

Maximum output MaxOutPwrPerBran power on the TX ch channel UlBranchGain UL channel gain

eNodeB

None

AAU

eNodeB

None

AAU

UlBandwidth

Supported UL Bandwidth

eNodeB

None

AAU

PATemperature

PA Temperature

eNodeB

None

AAU

Temperature

Board Temperature eNodeB

None

AAU

Level

Trunk Level

eNodeB

None

AAU

DeviceSerialNo

Physical RRU device serial No.

eNodeB

None

AAU

RatType

RRU standard capability

eNodeB

None

AAU

AccessDirection

Access Direction

eNodeB

None

AAU

MaxOutputOneCar

Maximum Output Power of TX Unit 0 (Single Carrier)

eNodeB

None

AAU

MaxOutputMutiCar

Maximum Output Power of TX Unit 0 (Multiple Carriers)

eNodeB

None

AAU

DlBandwidth

Supported DL Bandwidth

eNodeB

None

AAU

PHYID

Physical ID.

eNodeB

None

AAU

SW

Periodical Report Switch

eNodeB

None

AAU

TM

Test Time

eNodeB

None

AAU

CM

Check Mode

eNodeB

None

AAU

PSP

Power Statistic Period

eNodeB

None

AAU

PST

Power Statistic Time

eNodeB

None

AAU AAU

ULFREQ BER

UL Freq Bit Error Rate

eNodeB eNodeB

None None

AAU

InftDetectResult

Result

eNodeB

None

AAU

SETTYPE

Set Type

eNodeB

None

AAU

THRESHOLD

Threshold

eNodeB

None

AAU

CPRI Bit Rate

CPRI Line Rate

eNodeB

None

AAU AAU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

AAU

HardVer

Hardware Version

eNodeB

None

AAU AAU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

AAU

TestResult

Test Result

eNodeB

None

AAU

DLFREQ

Downlink Frequency

eNodeB

None

AAU

ULFREQ

Uplink Frequency

eNodeB

None

RE

AdmState

Administrative state eNodeB

LST RRU

RE

ALMPROCSW

VSWR alarm postprocessing switch

eNodeB

ADD RRU MOD RRU LST RRU

RE

ALMPROCTHRHL D

VSWR alarm postprocessing threshold

eNodeB

ADD RRU MOD RRU LST RRU

RE

ALMTHRHLD

VSWR alarm threshold

eNodeB

ADD RRU MOD RRU LST RRU

RE

PS

RRU Position

eNodeB

ADD RRU LST RRU

RE

RCN

RRU Chain No.

eNodeB

ADD RRU LST RRU

RE

TP

RRU Topo Position eNodeB

ADD RRU DSP RRUCHAINPHYTO PO LST RRU

RE

RS

RRU Work Standard

eNodeB

ADD RRU MOD RRU LST RRU

RE

RXNUM

Number of RX channels

eNodeB

ADD RRU MOD RRU DSP RRU LST RRU ADD RRU MOD RRU DSP RRU LST RRU DSP RRU

RE

TXNUM

Number of TX channels

eNodeB

RE

CarrierNumPerRxBr Number of carriers anch on the RX channel CarrierNumPerTxBr Number of carriers anch on the TX channel

eNodeB

RE

eNodeB

DSP RRU

RE

RxMinFreq

Minimum UL frequency

eNodeB

None

RE

RxMaxFreq

Maximum UL frequency

eNodeB

None

RE

TxMinFreq

Minimum DL frequency

eNodeB

None

RE

TxMaxFreq

Maximum DL frequency

eNodeB

None

RE

Maximum output MaxOutPwrPerBran power on the TX ch channel UlBranchGain UL channel gain

eNodeB

DSP RRU

RE

eNodeB

DSP RRU

RE

UlBandwidth

Supported UL Bandwidth

eNodeB

None

RE

PATemperature

PA Temperature

eNodeB

None

RE

Temperature

Board Temperature eNodeB

None

RE

Level

Trunk Level

eNodeB

DSP RRUCHAINPHYTO PO DSP RRUCHAINPHYTO PO

RE

DeviceSerialNo

Physical RRU device serial No.

eNodeB

RE

RatType

RRU standard capability

eNodeB

DSP RRUCHAINPHYTO PO

RE

AccessDirection

Access Direction

eNodeB

DSP RRU

RE

MaxOutputOneCar

Maximum Output Power of TX Unit 0 (Single Carrier)

eNodeB

None

RE

MaxOutputMutiCar

Maximum Output Power of TX Unit 0 (Multiple Carriers)

eNodeB

None

RE

DlBandwidth

Supported DL Bandwidth

eNodeB

None

RE

PHYID

Physical ID.

eNodeB

None

RE

SW

Periodical Report Switch

eNodeB

STR RRULNKTST

RE

TM

Test Time

eNodeB

STR RRULNKTST

RE

CM

Check Mode

eNodeB

None

RE

PSP

Power Statistic Period

eNodeB

None

RE

PST

Power Statistic Time

eNodeB

None

RE RE

ULFREQ BER

UL Freq Bit Error Rate

eNodeB eNodeB

None STR RRULNKTST

RE

InftDetectResult

Result

eNodeB

None

RE

SETTYPE

Set Type

eNodeB

SET CPRITHRESHOLD SET CPRITHRESHOLD DSP CPRITHRESHOLD

RE

THRESHOLD

Threshold

eNodeB

RE

CPRI Bit Rate

CPRI Line Rate

eNodeB

DSP CPRITHRESHOLD

RE

AlarmState

Alarm Status

eNodeB

None

RE

OpState

Operational State

eNodeB

None

RE

AvailabilityStatus

Availability Status

eNodeB

None

RE

Elabel

Electronic Label

eNodeB

None

RE RE

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

RE

BoardDesc

Description

eNodeB

None

RE

BoardManu

Date of Manufacture

eNodeB

None

RE

BoardVendor

Vendor

eNodeB

None

RE

BoardIssue

Issue Number

eNodeB

None

RE

RuType

Board Type

eNodeB

None

RE RE

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

RE

ObjectType

Object Type

eNodeB

None

RE

BoardTemperature Board Temperature eNodeB

None

RE RE

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

RE

ServiceType

Service Type

eNodeB

None

RE

DEVTYPE

DEVTYPE

eNodeB

None

RE RE

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

RE

HardVer

Hardware Version

eNodeB

None

RE RE

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

RE

TestResult

Test Result

eNodeB

None

RE

DLFREQ

Downlink Frequency

eNodeB

None

RE

ULFREQ

Uplink Frequency

eNodeB

None

RFU

CN

Cabinet No.

eNodeB

None

RFU

SRN

Subrack No.

eNodeB

None

RFU

SN

Slot No.

eNodeB

None

RFU

RT

RRU type

eNodeB

None

RFU

AdmState

Administrative state eNodeB

None

RFU

AlarmState

Alarm Status

eNodeB

None

RFU

OpState

Operational State

eNodeB

None

RFU

AvailabilityStatus

Availability Status

eNodeB

None

RFU

Elabel

Electronic Label

eNodeB

None

RFU RFU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

RFU

BoardDesc

Description

eNodeB

None

RFU

BoardManu

Date of Manufacture

eNodeB

None

RFU

BoardVendor

Vendor

eNodeB

None

RFU

BoardIssue

Issue Number

eNodeB

None

RFU

RuType

Board Type

eNodeB

None

RFU RFU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

RFU

ObjectType

Object Type

eNodeB

None

RFU

BoardTemperature Board Temperature eNodeB

None

RFU RFU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

RFU

ServiceType

Service Type

eNodeB

None

RFU

DEVTYPE

DEVTYPE

eNodeB

None

RFU

ALMPROCSW

VSWR alarm postprocessing switch

eNodeB

None

RFU

ALMPROCTHRHL D

VSWR alarm postprocessing threshold

eNodeB

None

RFU

ALMTHRHLD

VSWR alarm threshold

eNodeB

None

RFU

PS

RRU Position

eNodeB

None

RFU

RCN

RRU Chain No.

eNodeB

None

RFU

TP

RRU Topo Position eNodeB

None

RFU

RS

RRU Work Standard

eNodeB

None

RFU

RXNUM

Number of RX channels

eNodeB

None

RFU

TXNUM

Number of TX channels

eNodeB

None

RFU

CarrierNumPerRxBr Number of carriers anch on the RX channel CarrierNumPerTxBr Number of carriers anch on the TX channel

eNodeB

None

RFU

eNodeB

None

RFU

RxMinFreq

Minimum UL frequency

eNodeB

None

RFU

RxMaxFreq

Maximum UL frequency

eNodeB

None

RFU

TxMinFreq

Minimum DL frequency

eNodeB

None

RFU

TxMaxFreq

Maximum DL frequency

eNodeB

None

RFU

Maximum output MaxOutPwrPerBran power on the TX ch channel UlBranchGain UL channel gain

eNodeB

None

RFU

eNodeB

None

RFU

UlBandwidth

Supported UL Bandwidth

eNodeB

None

RFU

PATemperature

PA Temperature

eNodeB

None

RFU

Temperature

Board Temperature eNodeB

None

RFU

Level

Trunk Level

eNodeB

None

RFU

DeviceSerialNo

Physical RRU device serial No.

eNodeB

None

RFU

RatType

RRU standard capability

eNodeB

None

RFU

AccessDirection

Access Direction

eNodeB

None

RFU

MaxOutputOneCar

Maximum Output Power of TX Unit 0 (Single Carrier)

eNodeB

None

RFU

MaxOutputMutiCar

Maximum Output Power of TX Unit 0 (Multiple Carriers)

eNodeB

None

RFU

DlBandwidth

Supported DL Bandwidth

eNodeB

None

RFU

PHYID

Physical ID.

eNodeB

None

RFU

SW

Periodical Report Switch

eNodeB

None

RFU

TM

Test Time

eNodeB

None

RFU

CM

Check Mode

eNodeB

None

RFU

PSP

Power Statistic Period

eNodeB

None

RFU

PST

Power Statistic Time

eNodeB

None

RFU RFU

ULFREQ BER

UL Freq Bit Error Rate

eNodeB eNodeB

None None

RFU

InftDetectResult

Result

eNodeB

None

RFU

SETTYPE

Set Type

eNodeB

None

RFU

THRESHOLD

Threshold

eNodeB

None

RFU

CPRI Bit Rate

CPRI Line Rate

eNodeB

None

RFU RFU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

RFU

HardVer

Hardware Version

eNodeB

None

RFU RFU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

RFU

TestResult

Test Result

eNodeB

None

RFU

DLFREQ

Downlink Frequency

eNodeB

None

RFU

ULFREQ

Uplink Frequency

eNodeB

None

RRU

CN

Cabinet No.

eNodeB

None

RRU

SRN

Subrack No.

eNodeB

None

RRU

SN

Slot No.

eNodeB

None

RRU

RN

RRU Name

eNodeB

ADD RRU MOD RRU LST RRU

RRU

RT

RRU type

eNodeB

LST RRU

RRU RRU

TSTTYPE TSTTIME

Test Type Test Time

eNodeB eNodeB

None None

RRU

DELTATHRESHOL Delta Threshold D

eNodeB

None

RRU

Ant No.

Antenna Port No.

eNodeB

None

RRU

Test Result

Test Result

eNodeB

None

RRU RRU

RTWP Value

RTWP Value

eNodeB

None None

RTWP Delta Value RTWP Delta Value eNodeB

RRU

RTWP Max Value

RTWP Max Value

eNodeB

None

RRU

AdmState

Administrative state eNodeB

None

RRU

AlarmState

Alarm Status

eNodeB

None

RRU

OpState

Operational State

eNodeB

None

RRU

AvailabilityStatus

Availability Status

eNodeB

None

RRU

Elabel

Electronic Label

eNodeB

None

RRU RRU

BoardType BoardSerial

Type Serial Number

eNodeB eNodeB

None None

RRU

BoardDesc

Description

eNodeB

None

RRU

BoardManu

Date of Manufacture

eNodeB

None

RRU

BoardVendor

Vendor

eNodeB

None

RRU

BoardIssue

Issue Number

eNodeB

None

RRU

RuType

Board Type

eNodeB

None

RRU RRU

CpuDspUsage ObjectNumber

CPU/DSP Usage Object Number

eNodeB eNodeB

None None

RRU

ObjectType

Object Type

eNodeB

None

RRU

BoardTemperature Board Temperature eNodeB

None

RRU RRU

HPATemperature OperateResult

HPA Temperature Operate Result

eNodeB eNodeB

None None

RRU

ServiceType

Service Type

eNodeB

None

RRU

DEVTYPE

DEVTYPE

eNodeB

None

RRU

ALMPROCSW

VSWR alarm postprocessing switch

eNodeB

None

RRU

ALMPROCTHRHL D

VSWR alarm postprocessing threshold

eNodeB

None

RRU

ALMTHRHLD

VSWR alarm threshold

eNodeB

None

RRU

PS

RRU Position

eNodeB

None

RRU

RCN

RRU Chain No.

eNodeB

None

RRU

TP

RRU Topo Position eNodeB

None

RRU

RS

RRU Work Standard

eNodeB

None

RRU

RXNUM

Number of RX channels

eNodeB

None

RRU

TXNUM

Number of TX channels

eNodeB

None

RRU

CarrierNumPerRxBr Number of carriers anch on the RX channel CarrierNumPerTxBr Number of carriers anch on the TX channel

eNodeB

None

RRU

eNodeB

None

RRU

RxMinFreq

Minimum UL frequency

eNodeB

None

RRU

RxMaxFreq

Maximum UL frequency

eNodeB

None

RRU

TxMinFreq

Minimum DL frequency

eNodeB

None

RRU

TxMaxFreq

Maximum DL frequency

eNodeB

None

RRU

Maximum output MaxOutPwrPerBran power on the TX ch channel UlBranchGain UL channel gain

eNodeB

None

RRU

eNodeB

None

RRU

UlBandwidth

Supported UL Bandwidth

eNodeB

None

RRU

PATemperature

PA Temperature

eNodeB

None

RRU

Temperature

Board Temperature eNodeB

None

RRU

Level

Trunk Level

eNodeB

None

RRU

DeviceSerialNo

Physical RRU device serial No.

eNodeB

None

RRU

RatType

RRU standard capability

eNodeB

None

RRU

AccessDirection

Access Direction

eNodeB

None

RRU

MaxOutputOneCar

Maximum Output Power of TX Unit 0 (Single Carrier)

eNodeB

None

RRU

MaxOutputMutiCar

Maximum Output Power of TX Unit 0 (Multiple Carriers)

eNodeB

None

RRU

DlBandwidth

Supported DL Bandwidth

eNodeB

None

RRU

PHYID

Physical ID.

eNodeB

None

RRU

SW

Periodical Report Switch

eNodeB

None

RRU

TM

Test Time

eNodeB

None

RRU

CM

Check Mode

eNodeB

None

RRU

PSP

Power Statistic Period

eNodeB

None

RRU

PST

Power Statistic Time

eNodeB

None

RRU RRU

ULFREQ BER

UL Freq Bit Error Rate

eNodeB eNodeB

None None

RRU

InftDetectResult

Result

eNodeB

None

RRU

SETTYPE

Set Type

eNodeB

None

RRU

THRESHOLD

Threshold

eNodeB

None

RRU

CPRI Bit Rate

CPRI Line Rate

eNodeB

None

RRU RRU

NeName SoftVer

Office Name Software Version

eNodeB eNodeB

None None

RRU

HardVer

Hardware Version

eNodeB

None

RRU RRU

BtrmVer HwTestTime

BootRom Version Test Time

eNodeB eNodeB

None None

RRU

TestResult

Test Result

eNodeB

None

RRU

DLFREQ

Downlink Frequency

eNodeB

None

RRU

ULFREQ

Uplink Frequency

eNodeB

None

RRUCHAIN

RCN

RRU Chain No.

eNodeB

ADD RRUCHAIN DSP RRUCHAIN LST RRUCHAIN MOD RRUCHAIN RMV RRUCHAIN

RRUCHAIN

TT

Topo Type

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

BM

Backup Mode

eNodeB

ADD RRUCHAIN MOD RRUCHAIN LST RRUCHAIN

RRUCHAIN

HCN

Head Cabinet No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

HSRN

Head Subrack No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

HSN

Head Slot No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

HPN

Head Port No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

TCN

Tail Cabinet No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

TSRN

Tail Subrack No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

TSN

Tail Slot No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

TPN

Tail Port No.

eNodeB

ADD RRUCHAIN MOD RRUCHAIN DSP RRUCHAINPHYTO PO LST RRUCHAIN

RRUCHAIN

BRKPOS1

BreakPoint Position1

eNodeB

MOD RRUCHAIN LST RRUCHAIN

RRUCHAIN

BRKPOS2

BreakPoint Position2

eNodeB

MOD RRUCHAIN LST RRUCHAIN

RRUCHAIN

AT

Access Type

eNodeB

ADD RRUCHAIN MOD RRUCHAIN LST RRUCHAIN

RRUCHAIN

CR

CPRI Line Rate

eNodeB

ADD RRUCHAIN MOD RRUCHAIN LST RRUCHAIN

RRUCHAIN

ChainLevel

Chain Level

eNodeB

DSP RRUCHAIN

RRUCHAIN

RRUNum

RRU Number

eNodeB

DSP RRUCHAIN

RxBranch

CN

Cabinet No.

eNodeB

DSP RXBRANCH LST RXBRANCH MOD RXBRANCH

RxBranch

SRN

Subrack No.

eNodeB

DSP RXBRANCH LST RXBRANCH MOD RXBRANCH

RxBranch

SN

Slot No.

eNodeB

DSP RXBRANCH LST RXBRANCH MOD RXBRANCH

RxBranch

RXNO

RX Channel No.

eNodeB

DSP RXBRANCH LST RXBRANCH MOD RXBRANCH

RxBranch

RXSW

Logical Switch of RX Channel

eNodeB

MOD RXBRANCH DSP RXBRANCH LST RXBRANCH

RxBranch

ATTEN

Attenuation

eNodeB

MOD RXBRANCH DSP RXBRANCH LST RXBRANCH

RxBranch

PhyStatus

Physical Switch of RX Channel

eNodeB

DSP RXBRANCH

RxBranch

RxMinFreq1

Band 1 Minimum frequency

eNodeB

DSP RXBRANCH

RxBranch

RxMaxFreq1

Band 1 Maximum frequency

eNodeB

DSP RXBRANCH

RxBranch

UlBandwidth1

Band 1 UL Bandwidth

eNodeB

DSP RXBRANCH

RxBranch

RxMinFreq2

Band 2 Minimum frequency

eNodeB

DSP RXBRANCH

RxBranch

RxMaxFreq2

Band 2 Maximum frequency

eNodeB

DSP RXBRANCH

RxBranch

UlBandwidth2

Band 2 UL Bandwidth

eNodeB

DSP RXBRANCH

TxBranch

CN

Cabinet No.

eNodeB

DSP TXBRANCH DSP VSWR LOC RRUTC LST TXBRANCH MOD TXBRANCH STR VSWRTEST VER TXPOWER STR CROSFEEDTST

TxBranch

SRN

Subrack No.

eNodeB

DSP TXBRANCH DSP VSWR LOC RRUTC LST TXBRANCH MOD TXBRANCH STR VSWRTEST VER TXPOWER STR CROSFEEDTST

TxBranch

SN

Slot No.

eNodeB

DSP TXBRANCH DSP VSWR LOC RRUTC LST TXBRANCH MOD TXBRANCH STR VSWRTEST VER TXPOWER STR CROSFEEDTST

TxBranch

TXNO

TX Channel No.

eNodeB

DSP TXBRANCH DSP VSWR LOC RRUTC LST TXBRANCH MOD TXBRANCH STR VSWRTEST VER TXPOWER STR CROSFEEDTST

TxBranch

TXSW

Logical Switch of TX Channel

eNodeB

MOD TXBRANCH DSP TXBRANCH LST TXBRANCH

TxBranch

Vswr

VSWR

eNodeB

DSP TXBRANCH DSP VSWR STR VSWRTEST

TxBranch

PhyStatus

Physical Switch of TX Channel

eNodeB

DSP TXBRANCH

TxBranch

TRVAL

Turn OutPut Power eNodeB

VER TXPOWER

TxBranch

TFREQ

Txbranch Frequency

eNodeB

STR VSWRTEST

TxBranch

TPRV

Txbranch Power Relative Value

eNodeB

STR VSWRTEST

TxBranch TxBranch TxBranch

TESTTIME SiteNo SectNo

Test Time Site No. Sector No.

eNodeB eNodeB eNodeB

STR VSWRTEST STR VSWRTEST STR CROSFEEDTST STR VSWRTEST

TxBranch

SiteName

Office Name

eNodeB

STR VSWRTEST

TxBranch

TXMAXPWR

Maximum Output Power Support Setting of the TX Channel

eNodeB

LOC RRUTC

TxBranch

Maximum Output TXMAXPWRFORD Power of the TX SP Channel

eNodeB

DSP TXBRANCH

TxBranch

MaxOutputOneCar

Maximum Output Power of TX Unit (Single Carrier)

eNodeB

DSP TXBRANCH

TxBranch

MaxOutputMutiCar

Maximum Output Power of TX Unit (Multiple Carriers)

eNodeB

DSP TXBRANCH

TxBranch

TXHWMAXPWR

Hardware Maximum Output Power of the eNodeB TX Channel

DSP TXBRANCH

TxBranch

TxMinFreq1

Band 1 Minimum frequency

eNodeB

DSP TXBRANCH

TxBranch

TxMaxFreq1

Band 1 Maximum frequency

eNodeB

DSP TXBRANCH

TxBranch

DlBandwidth1

Band 1 DL Bandwidth

eNodeB

DSP TXBRANCH

TxBranch

TxMinFreq2

Band 2 Minimum frequency

eNodeB

DSP TXBRANCH

TxBranch

TxMaxFreq2

Band 2 Maximum frequency

eNodeB

DSP TXBRANCH

TxBranch

DlBandwidth2

Band 2 DL Bandwidth

eNodeB

DSP TXBRANCH

TxBranch

STFREQ

Start Test Frequency

eNodeB

STR CROSFEEDTST STR CROSFEEDTST STR CROSFEEDTST ADD NTPC MOD NTPC RMV NTPC SET MASTERNTPS

TxBranch

ETFREQ

End Test Frequency eNodeB

TxBranch

CrossTestResult

RESULT

eNodeB

NtpCp

IP

IPv4 Address of NTP Server

eNodeB

NtpCp

SYNCCYCLE

Synchronization Period

eNodeB

ADD NTPC MOD NTPC LST NTPC

NtpCp

PORT

Port Number

eNodeB

ADD NTPC MOD NTPC LST NTPC ADD NTPC MOD NTPC RMV NTPC SET MASTERNTPS ADD NTPC MOD NTPC RMV NTPC SET MASTERNTPS ADD NTPC MOD NTPC LST NTPC

NtpCp

MODE

IP Mode

eNodeB

NtpCp

IPV6

IPv6 Address of NTP Server

eNodeB

NtpCp

AUTHMODE

Authentication Mode

eNodeB

NtpCp

KEY

Authentication Key

eNodeB

ADD NTPC MOD NTPC LST NTPC

NtpCp

KEYID

Authentication Key Index

eNodeB

ADD NTPC MOD NTPC LST NTPC

NtpCp

MASTERFLAG

Master Flag

eNodeB

LST NTPC

TZ

ZONET

Time Zone

eNodeB

SET TZ LST TZ

TZ

DST

Dst Tag Information eNodeB

SET TZ

TZ

SM

Dst Start Mode

eNodeB

SET TZ

TZ

SMONTH

Dst Start Month

eNodeB

SET TZ

TZ

SDAY

Dst Start Day

eNodeB

SET TZ

TZ

SWSEQ

Dst Start Week Sequence

eNodeB

SET TZ

TZ

SWEEK

Dst Start Weekday eNodeB

SET TZ

TZ

ST

Dst Start Time

eNodeB

SET TZ

TZ

EM

Dst End Mode

eNodeB

SET TZ

TZ

EMONTH

Dst End Month

eNodeB

SET TZ

TZ

EDAY

Dst End Day

eNodeB

SET TZ

TZ

EWSEQ

Dst End Week Sequence

eNodeB

SET TZ

TZ

EWEEK

Dst End Weekday

eNodeB

SET TZ

TZ

ET

Dst End Time

eNodeB

SET TZ

TZ

TO

DST Offset

eNodeB

SET TZ

TZ

TIMEDIFF

Time Difference

eNodeB

SET TZ

OmuCurTime

DATE

Date

eNodeB

SET TIME

OmuCurTime

TIME

Time

eNodeB

SET TIME

OmuCurTime

DATETIME

Time

eNodeB

DSP TIME

TimeSrc

TIMESRC

Time Source

eNodeB

SET TIMESRC DSP TIMESRC LST LATESTSUCCDAT E LST TIMESRC

TimeSrc

DATETIME

Latest Successful Synchronization Time

eNodeB

LST LATESTSUCCDAT E

FTPCLTPORT

SERVERIP

FTP Server IP Address

eNodeB

ADD FTPSCLTDPORT MOD FTPSCLTDPORT RMV FTPSCLTDPORT LST FTPSCLTDPORT ADD FTPSCLTDPORT MOD FTPSCLTDPORT LST FTPSCLTDPORT ADD CNOPERATOREX TENDEDQCI LST CNOPERATOREX TENDEDQCI MOD CNOPERATOREX TENDEDQCI RMV CNOPERATOREX TENDEDQCI ADD CNOPERATOREX TENDEDQCI LST CNOPERATOREX TENDEDQCI MOD CNOPERATOREX TENDEDQCI RMV CNOPERATOREX TENDEDQCI ADD CNOPERATOREX TENDEDQCI MOD CNOPERATOREX TENDEDQCI LST CNOPERATOREX TENDEDQCI

FTPCLTPORT

PORT

Destination Port

eNodeB

CnOperatorExtendedQci CnOperatorId

CN Operator ID

eNodeB

CnOperatorExtendedQci ExtendedQci

CN Operator extended QCI

eNodeB

Service-based interServiceIrHoCfgGro CnOperatorExtendedQci RAT handover eNodeB upId policy group ID

Service-based interServiceIfHoCfgGrou CnOperatorExtendedQci Freq handover eNodeB pId policy group ID

ADD CNOPERATOREX TENDEDQCI MOD CNOPERATOREX TENDEDQCI LST CNOPERATOREX TENDEDQCI LST CNOPERATORST ANDARDQCI MOD CNOPERATORST ANDARDQCI

CnOperatorStandardQci CnOperatorId

CN Operator ID

eNodeB

CnOperatorStandardQci Qci

QoS Class Indication

eNodeB

LST CNOPERATORST ANDARDQCI MOD CNOPERATORST ANDARDQCI

Service-based interServiceIrHoCfgGro CnOperatorStandardQci RAT handover eNodeB upId policy group ID

MOD CNOPERATORST ANDARDQCI LST CNOPERATORST ANDARDQCI MOD CNOPERATORST ANDARDQCI LST CNOPERATORST ANDARDQCI LST CSFALLBACKBLIN DHOCFG MOD CSFALLBACKBLIN DHOCFG

Service-based interServiceIfHoCfgGrou CnOperatorStandardQci Freq handover eNodeB pId policy group ID

CSFallBackBlindHoCfg CnOperatorId

CN Operator ID

eNodeB

CSFallBackBlindHoCfg InterRatHighestPri

Highest priority InterRat

eNodeB

MOD CSFALLBACKBLIN DHOCFG LST CSFALLBACKBLIN DHOCFG

CSFallBackBlindHoCfg InterRatSecondPri

Second priority InterRat

eNodeB

MOD CSFALLBACKBLIN DHOCFG LST CSFALLBACKBLIN DHOCFG

CSFallBackBlindHoCfg InterRatLowestPri

Lowest priority InterRat

eNodeB

MOD CSFALLBACKBLIN DHOCFG LST CSFALLBACKBLIN DHOCFG

CSFallBackBlindHoCfg UtranLcsCap

UTRAN LCS capability

eNodeB

MOD CSFALLBACKBLIN DHOCFG LST CSFALLBACKBLIN DHOCFG MOD CSFALLBACKBLIN DHOCFG LST CSFALLBACKBLIN DHOCFG MOD CSFALLBACKBLIN DHOCFG LST CSFALLBACKBLIN DHOCFG ADD INTERPLMNHOLIS T LST INTERPLMNHOLIS T RMV INTERPLMNHOLIS T

CSFallBackBlindHoCfg GeranLcsCap

GERAN LCS capability

eNodeB

CSFallBackBlindHoCfg CdmaLcsCap

CDMA2000 LCS capability

eNodeB

InterPlmnHoList

CnOperatorId

CN Operator ID

eNodeB

InterPlmnHoList

TarMcc

Target Mobile country code

eNodeB

ADD INTERPLMNHOLIS T LST INTERPLMNHOLIS T RMV INTERPLMNHOLIS T

InterPlmnHoList

TarMnc

Target Mobile network code

eNodeB

ADD INTERPLMNHOLIS T LST INTERPLMNHOLIS T RMV INTERPLMNHOLIS T

RatFreqPriorityGrou RAT frequency RatFreqPriorityGroup pId priority group ID

eNodeB

ADD RATFREQPRIORIT YGROUP LST RATFREQPRIORIT YGROUP MOD RATFREQPRIORIT YGROUP RMV RATFREQPRIORIT YGROUP

RatFreqPriorityGroupRatType

RAT Type

eNodeB

ADD RATFREQPRIORIT YGROUP LST RATFREQPRIORIT YGROUP MOD RATFREQPRIORIT YGROUP RMV RATFREQPRIORIT YGROUP ADD RATFREQPRIORIT YGROUP LST RATFREQPRIORIT YGROUP MOD RATFREQPRIORIT YGROUP RMV RATFREQPRIORIT YGROUP

RatFreqPriorityGroupDlEarfcn

Downlink EARFCN eNodeB

RatFreqPriorityGroupPriority

Priority

eNodeB

ADD RATFREQPRIORIT YGROUP MOD RATFREQPRIORIT YGROUP LST RATFREQPRIORIT YGROUP

RatFreqPriorityGroupBandIndicator

GERAN Frequency eNodeB Indicator

ADD RATFREQPRIORIT YGROUP MOD RATFREQPRIORIT YGROUP LST RATFREQPRIORIT YGROUP

ServiceIfHoCfgGroupCnOperatorId

CN Operator ID

eNodeB

ADD SERVICEIFHOCFG GROUP LST SERVICEIFHOCFG GROUP MOD SERVICEIFHOCFG GROUP RMV SERVICEIFHOCFG GROUP ADD SERVICEIFHOCFG GROUP LST SERVICEIFHOCFG GROUP MOD SERVICEIFHOCFG GROUP RMV SERVICEIFHOCFG GROUP

Service-based interServiceIfHoCfgGrou ServiceIfHoCfgGroup Freq handover eNodeB pId policy group ID

ServiceIfHoCfgGroupInterFreqHoState

Inter-Freq handover eNodeB state

ADD SERVICEIFHOCFG GROUP MOD SERVICEIFHOCFG GROUP LST SERVICEIFHOCFG GROUP

ServiceIfHoCfgGroupDlEarfcn

Downlink EARFCN eNodeB

ADD SERVICEIFHOCFG GROUP MOD SERVICEIFHOCFG GROUP LST SERVICEIFHOCFG GROUP ADD SERVICEIRHOCF GGROUP LST SERVICEIRHOCF GGROUP MOD SERVICEIRHOCF GGROUP RMV SERVICEIRHOCF GGROUP ADD SERVICEIRHOCF GGROUP LST SERVICEIRHOCF GGROUP MOD SERVICEIRHOCF GGROUP RMV SERVICEIRHOCF GGROUP ADD SERVICEIRHOCF GGROUP MOD SERVICEIRHOCF GGROUP LST SERVICEIRHOCF GGROUP

ServiceIrHoCfgGroupCnOperatorId

CN Operator ID

eNodeB

Service-based interServiceIrHoCfgGro ServiceIrHoCfgGroup RAT handover eNodeB upId policy group ID

ServiceIrHoCfgGroupInterRatHoState

Inter-RAT handover eNodeB state

SpidCfg

Spid

Spid

eNodeB

ADD SPIDCFG LST SPIDCFG MOD SPIDCFG RMV SPIDCFG

SpidCfg

DrxStatus

Drx status

eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

SpidCfg

RatFreqPriorityInd

RAT frequency priority indication

eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

SpidCfg

RatFreqPriorityGrou RAT frequency pId priority group ID

eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

SpidCfg

PreallocationStatus PreallocationStatus eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

SpidCfg

InterFreqMlbSwitch

InterFreq Mlb Switch

eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

SpidCfg

InterRatMlbSwitch

InterRat Mlb Switch eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

SpidCfg

SPID-based HoBackToHPLMNS Handover Back To witch HPLMN Switch

eNodeB

ADD SPIDCFG MOD SPIDCFG LST SPIDCFG

CounterCheckPara CounterCheckTimer Counter check timer eNodeB

MOD COUNTERCHECK PARA LST COUNTERCHECK PARA

CounterCheckPara

CounterCheckCoun Counter check tNum count number

eNodeB

MOD COUNTERCHECK PARA LST COUNTERCHECK PARA

CounterCheckPara

CounterCheckUser Counter check user eNodeB RelSwitch Release switch

MOD COUNTERCHECK PARA LST COUNTERCHECK PARA

ENodeBCipherCap PrimaryCipherAlgo

Primary cipher algorithm

eNodeB

MOD ENODEBCIPHERC AP LST ENODEBCIPHERC AP

ENodeBCipherCap SecondCipherAlgo

Second cipher algorithm

eNodeB

MOD ENODEBCIPHERC AP LST ENODEBCIPHERC AP

ENodeBCipherCap ThirdCipherAlgo

Third cipher algorithm

eNodeB

MOD ENODEBCIPHERC AP LST ENODEBCIPHERC AP

S1MessageWaiting S1 Message ENodeBConnStateTimer Timer Waiting Timer

eNodeB

MOD ENODEBCONNST ATETIMER LST ENODEBCONNST ATETIMER

X2MessageWaiting X2 Message ENodeBConnStateTimer Timer Waiting Timer

eNodeB

MOD ENODEBCONNST ATETIMER LST ENODEBCONNST ATETIMER

UuMessageWaiting UU Message ENodeBConnStateTimer Timer Waiting Timer

eNodeB

MOD ENODEBCONNST ATETIMER LST ENODEBCONNST ATETIMER

ENodeBIntegrityCap PrimaryIntegrityAlgo

Primary integrity algorithm

eNodeB

MOD ENODEBINTEGRIT YCAP LST ENODEBINTEGRIT YCAP

ENodeBIntegrityCap SecondIntegrityAlgo

Second integrity algorithm

eNodeB

MOD ENODEBINTEGRIT YCAP LST ENODEBINTEGRIT YCAP

ENodeBIntegrityCap ThirdIntegrityAlgo

Third integrity algorithm

eNodeB

MOD ENODEBINTEGRIT YCAP LST ENODEBINTEGRIT YCAP

GlobalProcSwitch

X2SonSetupSwitch

The Switch of X2 setup by SON

eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

GlobalProcSwitch

X2SonLinkSetupTy The method of X2 pe setup by SON

eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

GlobalProcSwitch

SriAdaptiveSwitch

SRI adaptive switch eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

GlobalProcSwitch

LcgProfile

LCG Profile

eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

GlobalProcSwitch

RncPoolHoRimSwit RNC POOL HO ch RIM Switch

eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

GlobalProcSwitch

UU Message UuMsgSimulSendS Simultaneous witch Sending Switch

eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

GlobalProcSwitch

Update eNB X2BasedUptENode Configuration Via BCfgSwitch X2 Switch

eNodeB

MOD GLOBALPROCSWI TCH LST GLOBALPROCSWI TCH

PdcpRohcPara

RohcSwitch

ROHC switch

eNodeB

MOD PDCPROHCPARA LST PDCPROHCPARA

PdcpRohcPara

HighestMode

ROHC Highest mode

eNodeB

MOD PDCPROHCPARA LST PDCPROHCPARA

PdcpRohcPara

Profiles

Compression profiles

eNodeB

MOD PDCPROHCPARA LST PDCPROHCPARA

RrcConnStateTimer T302

Timer302

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

RrcConnStateTimer

T320ForLoadBalan Timer320 for load ce balance

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

RrcConnStateTimer T304ForEutran

Timer304 for EUTRAN

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

RrcConnStateTimer T304ForGeran

Timer304 for GERAN

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

RrcConnStateTimer T320ForOther

Timer320 for other

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

RrcConnStateTimer UeInactiveTimer

Ue inactive timer

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

RrcConnStateTimer UlSynTimer

UlSynTimer

eNodeB

MOD RRCCONNSTATET IMER LST RRCCONNSTATET IMER

TceIpMapping

TceId

TCE ID

eNodeB

ADD TCEIPMAPPING LST TCEIPMAPPING MOD TCEIPMAPPING RMV TCEIPMAPPING ADD TCEIPMAPPING MOD TCEIPMAPPING LST TCEIPMAPPING ADD TCEIPMAPPING MOD TCEIPMAPPING LST TCEIPMAPPING

TceIpMapping

IPMode

IP Mode

eNodeB

TceIpMapping

TceIpV4Addr

TCE IPv4 Address

eNodeB

TceIpMapping

TceIpV6Addr

TCE IPv6 Address

eNodeB

ADD TCEIPMAPPING MOD TCEIPMAPPING LST TCEIPMAPPING LST CELLDLPCPDSCH PA MOD CELLDLPCPDSCH PA

CellDlpcPdschPa

LocalCellId

Local cell ID

eNodeB

CellDlpcPdschPa

PdschPaAdjSwitch PA adjusting switch eNodeB

MOD CELLDLPCPDSCH PA LST CELLDLPCPDSCH PA

CellDlpcPdschPa

PaPcOff

PA for even power distribution

eNodeB

MOD CELLDLPCPDSCH PA LST CELLDLPCPDSCH PA

CellDrxPara

LocalCellId

Local cell ID

eNodeB

LST CELLDRXPARA MOD CELLDRXPARA

CellDrxPara

FddEnterDrxThd

FDD enter DRX threshold

eNodeB

MOD CELLDRXPARA LST CELLDRXPARA

CellDrxPara

FddExitDrxThd

FDD exit DRX threshold

eNodeB

MOD CELLDRXPARA LST CELLDRXPARA

CellDrxPara

TddEnterDrxThdUl

TDD enter DRX threshold Uplink

eNodeB

MOD CELLDRXPARA LST CELLDRXPARA

CellDrxPara

TddExitDrxThdUl

TDD exit DRX threshold Uplink

eNodeB

MOD CELLDRXPARA LST CELLDRXPARA

CellDrxPara

TddEnterDrxThdDl

TDD enter DRX eNodeB threshold Downlink

MOD CELLDRXPARA LST CELLDRXPARA

CellDrxPara

TddExitDrxThdDl

TDD exit DRX eNodeB threshold Downlink

MOD CELLDRXPARA LST CELLDRXPARA

CellDrxPara

DataAmountStatTim Data amount er Statistic timer

eNodeB

MOD CELLDRXPARA LST CELLDRXPARA

CellUlpcDedic

LocalCellId

Local cell ID

eNodeB

LST CELLULPCDEDIC MOD CELLULPCDEDIC

CellUlpcDedic

DeltaMcsEnabled

Delta-MCS enable eNodeB or disable indication

MOD CELLULPCDEDIC LST CELLULPCDEDIC

CellUlpcDedic

Power Offset of PSrsOffsetDeltaMc SRS to PUSCH with eNodeB sDisable DeltaMcsEnabled Off

MOD CELLULPCDEDIC LST CELLULPCDEDIC

CellUlpcDedic

Power Offset of PSrsOffsetDeltaMc SRS to PUSCH with eNodeB sEnable DeltaMcsEnabled On

MOD CELLULPCDEDIC LST CELLULPCDEDIC

CellUlpcDedic

FilterRsrp

RSRP filtering coefficient

eNodeB

MOD CELLULPCDEDIC LST CELLULPCDEDIC

DistBasedHO

LocalCellId

Local cell ID

eNodeB

LST DISTBASEDHO MOD DISTBASEDHO

DistBasedHO

Distance-based DistBasedMeasObj Measurement Type Object Type

eNodeB

MOD DISTBASEDHO LST DISTBASEDHO

DistBasedHO

DistBasedHOThd

Distance-based Handover Threshold

eNodeB

MOD DISTBASEDHO LST DISTBASEDHO

DrxParaGroup

LocalCellId

Local cell ID

eNodeB

ADD DRXPARAGROUP LST DRXPARAGROUP MOD DRXPARAGROUP RMV DRXPARAGROUP ADD DRXPARAGROUP LST DRXPARAGROUP MOD DRXPARAGROUP RMV DRXPARAGROUP

DrxParaGroup

DrxParaGroupId

DRX parameter group ID

eNodeB

DrxParaGroup

EnterDrxSwitch

Enter DRX Switch

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

OnDurationTimer

On Duration Timer

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

DrxInactivityTimer

DRX Inactivity Timer

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

DrxReTxTimer

DRX Retransmission Timer

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

LongDrxCycle

Long DRX Cycle

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

SupportShortDrx

Short-cycle DRX eNodeB supported indication

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

ShortDrxCycle

Short DRX Cycle

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

DrxParaGroup

DrxShortCycleTimer

DRX Short Cycle Timer

eNodeB

ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP

InterRatHoCommGroup LocalCellId

Local cell ID

eNodeB

ADD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP RMV INTERRATHOCOM MGROUP ADD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP RMV INTERRATHOCOM MGROUP

InterRatHoCommGr InterRAT handover InterRatHoCommGroup eNodeB oupId common group ID

InterRatHoA1A2Hys InterRAT A1A2 InterRatHoCommGroup t hysteresis

eNodeB

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP

InterRatHoA1A2Tim InterRAT A1A2 time InterRatHoCommGroup eNodeB eToTrig to trigger

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP

InterRatHoA1ThdRs InterRAT A1 RSRP InterRatHoCommGroup eNodeB rp trigger threshold

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP

InterRatHoA1ThdRs InterRAT A1 RSRQ InterRatHoCommGroup eNodeB rq trigger threshold

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP

InterRatHoA2ThdRs InterRAT A2 RSRP InterRatHoCommGroup eNodeB rp trigger threshold

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP

InterRatHoA2ThdRs InterRAT A2 RSRQ InterRatHoCommGroup eNodeB rq trigger threshold

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP

BlindHoA2ThdOffse Blind HO A2 InterRatHoCommGroup t Threshold Offset

eNodeB

ADD INTERRATHOCOM MGROUP MOD INTERRATHOCOM MGROUP LST INTERRATHOCOM MGROUP ADD INTERRATHOCDM A1XRTTGROUP LST INTERRATHOCDM A1XRTTGROUP MOD INTERRATHOCDM A1XRTTGROUP RMV INTERRATHOCDM A1XRTTGROUP ADD INTERRATHOCDM A1XRTTGROUP LST INTERRATHOCDM A1XRTTGROUP MOD INTERRATHOCDM A1XRTTGROUP RMV INTERRATHOCDM A1XRTTGROUP

InterRatHoCdma1xRttGroup LocalCellId

Local cell ID

eNodeB

InterRAT handover InterRatHoCdma1x to InterRatHoCdma1xRttGroup eNodeB RttGroupId CDMA20001xRTT group ID

InterRatHoCdmaB1 CDMA20001XRTT InterRatHoCdma1xRttGroup eNodeB Hyst handover hysteresis

ADD INTERRATHOCDM A1XRTTGROUP MOD INTERRATHOCDM A1XRTTGROUP LST INTERRATHOCDM A1XRTTGROUP

CoverageBased InterRatHoCdmaB1 InterRatHoCdma1xRttGroup CDMA20001XRTT ThdPs trigger threshold

eNodeB

ADD INTERRATHOCDM A1XRTTGROUP MOD INTERRATHOCDM A1XRTTGROUP LST INTERRATHOCDM A1XRTTGROUP

InterRatHoCdmaB1 CDMA20001XRTT InterRatHoCdma1xRttGroup TimeToTrig time to trigger

eNodeB

ADD INTERRATHOCDM A1XRTTGROUP MOD INTERRATHOCDM A1XRTTGROUP LST INTERRATHOCDM A1XRTTGROUP

Load Service Based LdSvBasedHoCdm InterRatHoCdma1xRttGroup CDMA20001XRTT eNodeB aB1ThdPs trigger threshold

ADD INTERRATHOCDM A1XRTTGROUP MOD INTERRATHOCDM A1XRTTGROUP LST INTERRATHOCDM A1XRTTGROUP

CellExtendedQci

ExtendedQci

Extended QCI

eNodeB

ADD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI RMV CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI RMV CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI

CellExtendedQci

LocalCellId

Local cell ID

eNodeB

CellExtendedQci

InterFreqHoGroupId

Interfreq handover group ID

eNodeB

CellExtendedQci

InterRAT handover InterRatHoCdma1x to eNodeB RttGroupId CDMA20001xRTT group ID

CellExtendedQci

InterRAT handover InterRatHoCdmaHr to eNodeB pdGroupId CDMA2000HRPD group ID

CellExtendedQci

InterRatHoCommGr InterRAT handover eNodeB oupId common group ID

ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI ADD CELLEXTENDEDQ CI MOD CELLEXTENDEDQ CI LST CELLEXTENDEDQ CI LST CELLSTANDARDQ CI MOD CELLSTANDARDQ CI

CellExtendedQci

InterRatHoGeranGr InterRAT handover eNodeB oupId to GERAN group ID

CellExtendedQci

InterRatHoUtranGro InterRAT handover eNodeB upId to UTRAN Group ID

CellExtendedQci

IntraFreqHoGroupId

Intrafreq handover group ID

eNodeB

CellExtendedQci

DrxParaGroupId

DRX parameter group ID

eNodeB

CellStandardQci

LocalCellId

Local cell ID

eNodeB

CellStandardQci

Qci

QoS Class Indication

eNodeB

LST CELLSTANDARDQ CI MOD CELLSTANDARDQ CI

CellStandardQci

InterFreqHoGroupId

Interfreq handover group ID

eNodeB

MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI

CellStandardQci

InterRAT handover InterRatHoCdma1x to eNodeB RttGroupId CDMA20001xRTT group ID

CellStandardQci

InterRAT handover InterRatHoCdmaHr to eNodeB pdGroupId CDMA2000HRPD group ID

CellStandardQci

InterRatHoCommGr InterRAT handover eNodeB oupId common group ID

MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI

CellStandardQci

InterRatHoGeranGr InterRAT handover eNodeB oupId to GERAN group ID

MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI

CellStandardQci

InterRatHoUtranGro InterRAT handover eNodeB upId to UTRAN Group ID

MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI

CellStandardQci

IntraFreqHoGroupId

Intrafreq handover group ID

eNodeB

CellStandardQci

DrxParaGroupId

DRX parameter group ID

eNodeB

CellStandardQci

SriPeriod

SRI Period

eNodeB

MOD CELLSTANDARDQ CI LST CELLSTANDARDQ CI

InterRatHoCdmaHrpdGroup LocalCellId

Local cell ID

eNodeB

ADD INTERRATHOCDM AHRPDGROUP LST INTERRATHOCDM AHRPDGROUP MOD INTERRATHOCDM AHRPDGROUP RMV INTERRATHOCDM AHRPDGROUP

InterRAT handover InterRatHoCdmaHr to InterRatHoCdmaHrpdGroup eNodeB pdGroupId CDMA2000HRPD group ID

ADD INTERRATHOCDM AHRPDGROUP LST INTERRATHOCDM AHRPDGROUP MOD INTERRATHOCDM AHRPDGROUP RMV INTERRATHOCDM AHRPDGROUP

InterRatHoCdmaB1 CDMA2000HRPD InterRatHoCdmaHrpdGroup eNodeB Hyst handover hysteresis

ADD INTERRATHOCDM AHRPDGROUP MOD INTERRATHOCDM AHRPDGROUP LST INTERRATHOCDM AHRPDGROUP

CoverageBased InterRatHoCdmaB1 InterRatHoCdmaHrpdGroup CDMA2000HRPD ThdPs trigger threshold

eNodeB

ADD INTERRATHOCDM AHRPDGROUP MOD INTERRATHOCDM AHRPDGROUP LST INTERRATHOCDM AHRPDGROUP

InterRatHoCdmaB1 CDMA2000HRPD InterRatHoCdmaHrpdGroup TimeToTrig time to trigger

eNodeB

ADD INTERRATHOCDM AHRPDGROUP MOD INTERRATHOCDM AHRPDGROUP LST INTERRATHOCDM AHRPDGROUP

Load Service Based LdSvBasedHoCdm InterRatHoCdmaHrpdGroup CDMA2000HRPD eNodeB aB1ThdPs trigger threshold

ADD INTERRATHOCDM AHRPDGROUP MOD INTERRATHOCDM AHRPDGROUP LST INTERRATHOCDM AHRPDGROUP

InterRatHoGeranGroup LocalCellId

Local cell ID

eNodeB

ADD INTERRATHOGER ANGROUP LST INTERRATHOGER ANGROUP MOD INTERRATHOGER ANGROUP RMV INTERRATHOGER ANGROUP ADD INTERRATHOGER ANGROUP LST INTERRATHOGER ANGROUP MOD INTERRATHOGER ANGROUP RMV INTERRATHOGER ANGROUP

InterRatHoGeranGr InterRAT handover InterRatHoGeranGroup eNodeB oupId to GERAN group ID

InterRatHoGeranB1 GERAN handover InterRatHoGeranGroup Hyst hysteresis

eNodeB

ADD INTERRATHOGER ANGROUP MOD INTERRATHOGER ANGROUP LST INTERRATHOGER ANGROUP

CoverageBased InterRatHoGeranB1 InterRatHoGeranGroup GERAN trigger Thd threshold

eNodeB

ADD INTERRATHOGER ANGROUP MOD INTERRATHOGER ANGROUP LST INTERRATHOGER ANGROUP

InterRatHoGeranB1 GERAN time to InterRatHoGeranGroup TimeToTrig trigger

eNodeB

ADD INTERRATHOGER ANGROUP MOD INTERRATHOGER ANGROUP LST INTERRATHOGER ANGROUP

Load Service Based LdSvBasedHoGera InterRatHoGeranGroup Geran EventB1 eNodeB nB1Thd trigger threshold

ADD INTERRATHOGER ANGROUP MOD INTERRATHOGER ANGROUP LST INTERRATHOGER ANGROUP

InterRatHoUtranGroup LocalCellId

Local cell ID

eNodeB

ADD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP RMV INTERRATHOUTR ANGROUP ADD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP RMV INTERRATHOUTR ANGROUP

InterRatHoUtranGro InterRAT handover InterRatHoUtranGroup eNodeB upId to UTRAN Group ID

CoverageBased InterRatHoUtranB1 InterRatHoUtranGroup UTRAN ECN0 ThdEcn0 trigger threshold

eNodeB

ADD INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP

CoverageBased InterRatHoUtranB1 InterRatHoUtranGroup UTRAN RSCP ThdRscp trigger threshold

eNodeB

ADD INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP

InterRatHoUtranB1 UTRAN handover InterRatHoUtranGroup Hyst hysteresis

eNodeB

ADD INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP

InterRatHoUtranB1 UTRAN time to InterRatHoUtranGroup TimeToTrig trigger

eNodeB

ADD INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP

Load Service Based LdSvBasedHoUtran InterRatHoUtranGroup UTRANB1 ECN0 eNodeB B1ThdEcn0 threshold

ADD INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP

Load Service Based LdSvBasedHoUtran UTRAN EventB1 InterRatHoUtranGroup eNodeB B1ThdRscp RSCP trigger threshold

ADD INTERRATHOUTR ANGROUP MOD INTERRATHOUTR ANGROUP LST INTERRATHOUTR ANGROUP

InterFreqHoGroup

LocalCellId

Local cell ID

eNodeB

ADD INTERFREQHOGR OUP LST INTERFREQHOGR OUP MOD INTERFREQHOGR OUP RMV INTERFREQHOGR OUP ADD INTERFREQHOGR OUP LST INTERFREQHOGR OUP MOD INTERFREQHOGR OUP RMV INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoGroupId

Interfreq handover group ID

eNodeB

InterFreqHoGroup

InterFreqHoA1A2Hy Interfreq A1A2 st hysteresis

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA1A2Ti Interfreq A1A2 time eNodeB meToTrig to trigger

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA1ThdR Interfreq A1 RSRP srp threshold

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA1ThdR Interfreq A1 RSRQ eNodeB srq threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA2ThdR Interfreq A2 RSRP srp threshold

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA2ThdR Interfreq A2 RSRQ eNodeB srq threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA4Hyst

Interfreq handover hysteresis

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

CoverageBased InterFreqHoA4ThdR Interfreq RSRP srp threshold

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

CoverageBased InterFreqHoA4ThdR Interfreq RSRQ srq threshold

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA4Time Interfreq HandOver eNodeB ToTrig Time to Trigger

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

Load Based InterFreqLoadBase Interfreq RSRP dHoA4ThdRsrp threshold

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

Load Based InterFreqLoadBase Interfreq RSRQ dHoA4ThdRsrq threshold

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

Freq Priority Based FreqPriInterFreqHo Interfreq A1 RSRP eNodeB A1ThdRsrp threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

Freq Priority Based FreqPriInterFreqHo Interfreq A1 RSRQ eNodeB A1ThdRsrq threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

InterFreqHoA3Offse Interfreq A3 offset t

eNodeB

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

A3InterFreqHoA1Th A3 based interfreq eNodeB dRsrp A1 RSRP threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

A3InterFreqHoA2Th A3 based Interfreq eNodeB dRsrp A2 RSRP threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

Freq Priority Based FreqPriInterFreqHo Interfreq A2 RSRP eNodeB A2ThdRsrp threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP

InterFreqHoGroup

Freq Priority Based FreqPriInterFreqHo Interfreq A2 RSRQ eNodeB A2ThdRsrq threshold

ADD INTERFREQHOGR OUP MOD INTERFREQHOGR OUP LST INTERFREQHOGR OUP ADD INTRAFREQHOGR OUP LST INTRAFREQHOGR OUP MOD INTRAFREQHOGR OUP RMV INTRAFREQHOGR OUP ADD INTRAFREQHOGR OUP LST INTRAFREQHOGR OUP MOD INTRAFREQHOGR OUP RMV INTRAFREQHOGR OUP

IntraFreqHoGroup

LocalCellId

Local cell ID

eNodeB

IntraFreqHoGroup

IntraFreqHoGroupId

Intrafreq handover group ID

eNodeB

IntraFreqHoGroup

IntraFreqHoA3Hyst

Intrafreq handover hysteresis

eNodeB

ADD INTRAFREQHOGR OUP MOD INTRAFREQHOGR OUP LST INTRAFREQHOGR OUP

IntraFreqHoGroup

IntraFreqHoA3Offse Intrafreq handover t offset

eNodeB

ADD INTRAFREQHOGR OUP MOD INTRAFREQHOGR OUP LST INTRAFREQHOGR OUP

IntraFreqHoGroup

IntraFreqHoA3Time Intrafreq handover ToTrig time to trigger

eNodeB

ADD INTRAFREQHOGR OUP MOD INTRAFREQHOGR OUP LST INTRAFREQHOGR OUP

CnOperator

CnOperatorId

CN Operator ID

eNodeB

ADD CNOPERATOR LST CNOPERATOR MOD CNOPERATOR RMV CNOPERATOR

CnOperator

CnOperatorName

CN Operator name eNodeB

ADD CNOPERATOR MOD CNOPERATOR LST CNOPERATOR

CnOperator

CnOperatorType

CN Operator type

eNodeB

ADD CNOPERATOR MOD CNOPERATOR LST CNOPERATOR

CnOperator

Mcc

Mobile country code eNodeB

ADD CNOPERATOR MOD CNOPERATOR LST CNOPERATOR

CnOperator

Mnc

Mobile network code

eNodeB

ADD CNOPERATOR MOD CNOPERATOR LST CNOPERATOR

CnOperatorIpPath

IpPathId

IP path ID

eNodeB

ADD CNOPERATORIPP ATH LST CNOPERATORIPP ATH MOD CNOPERATORIPP ATH RMV CNOPERATORIPP ATH ADD CNOPERATORIPP ATH MOD CNOPERATORIPP ATH LST CNOPERATORIPP ATH ADD CNOPERATORTA LST CNOPERATORTA MOD CNOPERATORTA RMV CNOPERATORTA ADD CNOPERATORTA MOD CNOPERATORTA LST CNOPERATORTA

CnOperatorIpPath

CnOperatorId

CN Operator ID

eNodeB

CnOperatorTa

TrackingAreaId

Tracking area ID

eNodeB

CnOperatorTa

CnOperatorId

CN Operator ID

eNodeB

CnOperatorTa

Tac

Tracking area code eNodeB

ADD CNOPERATORTA MOD CNOPERATORTA LST CNOPERATORTA

Emc

CnOperatorId

CN Operator ID

eNodeB

LST EMC MOD EMC

Emc

EmcEnable

Emergency call enabled switch

eNodeB

MOD EMC LST EMC

Emc

Emergency call EmcEnableInLimite enabled switch in dMode limited mode

eNodeB

MOD EMC LST EMC

Emc

EmcDedicatedBear The ARP of EMC erARP dedicated bearer

eNodeB

MOD EMC LST EMC

Emc

EmcDefaultBearerA The ARP of EMC RP default bearer

eNodeB

MOD EMC LST EMC

ENodeBSharingMo eNodeB sharing ENodeBSharingMode de mode

eNodeB

MOD ENODEBSHARING MODE LST ENODEBSHARING MODE

LicenseSharingPolicyCnOperatorId

CN Operator ID

eNodeB

ADD LICENSESHARING POLICY LST LICENSESHARING POLICY MOD LICENSESHARING POLICY RMV LICENSESHARING POLICY ADD LICENSESHARING POLICY MOD LICENSESHARING POLICY LST LICENSESHARING POLICY

LicenseSharingPolicyMaxUserNumRate

The proportion of the maximum number of users

eNodeB

S1ReestTimer

S1ReestMinTimer

S1 reestablish min timer length

eNodeB

MOD S1REESTTIMER LST S1REESTTIMER MOD S1REESTTIMER LST S1REESTTIMER

S1ReestTimer

S1ReestMaxTimer

S1 reestablish max eNodeB timer length

S1Interface

S1InterfaceId

S1Interface ID

eNodeB

S1Interface

S1SctpLinkId

S1 SCTP link ID

eNodeB

ADD S1INTERFACE BLK S1INTERFACE DSP S1INTERFACE MOD S1INTERFACE RMV S1INTERFACE RST S1INTERFACE ADD S1INTERFACE MOD S1INTERFACE DSP S1INTERFACE ADD S1INTERFACE MOD S1INTERFACE DSP S1INTERFACE

S1Interface

CnOperatorId

CN Operator ID

eNodeB

S1Interface

MmeRelease

MME Release

eNodeB

ADD S1INTERFACE MOD S1INTERFACE DSP S1INTERFACE

S1Interface

S1InterfaceIsBlock

S1Interface is block eNodeB

ADD S1INTERFACE MOD S1INTERFACE DSP S1INTERFACE DSP S1INTERFACE DSP S1INTERFACE DSP S1INTERFACE

S1Interface

S1InterfaceState

S1Interface state

eNodeB

S1Interface

S1SctpLinkState

S1 SCTP Link State eNodeB

S1Interface

MmeIsOverLoad

MME is overloaded eNodeB

S1Interface

S1InterfaceUserNu S1Interface user m number

eNodeB

DSP S1INTERFACE

S1Interface

MmeName

MME name

eNodeB

DSP S1INTERFACE

S1Interface

ServedPlmns

Served PLMNs

eNodeB

DSP S1INTERFACE

S1Interface

ServedGummeis

Served GUMMEIs

eNodeB

DSP S1INTERFACE

S1Interface

RelativeMmeCap

MME relative capacity

eNodeB

DSP S1INTERFACE

S1Interface

S1LinkFaultReason

S1 Link Fault Reason

eNodeB

DSP S1INTERFACE

MmeFeatureCfg

S1InterfaceId

S1Interface ID

eNodeB

LST MMEFEATURECF G MOD MMEFEATURECF G

MmeFeatureCfg

MdtEnable

MME supporting MDT or not

eNodeB

MOD MMEFEATURECF G LST MMEFEATURECF G

X2BlackWhiteList

Mcc

Mobile country code eNodeB

ADD X2BLACKWHITELI ST RMV X2BLACKWHITELI ST LST X2BLACKWHITELI ST

X2BlackWhiteList

Mnc

Mobile network code

eNodeB

ADD X2BLACKWHITELI ST RMV X2BLACKWHITELI ST LST X2BLACKWHITELI ST

X2BlackWhiteList

ENodeBId

eNodeB ID

eNodeB

ADD X2BLACKWHITELI ST RMV X2BLACKWHITELI ST LST X2BLACKWHITELI ST ADD X2BLACKWHITELI ST LST X2BLACKWHITELI ST ADD X2INTERFACE DSP X2INTERFACE MOD X2INTERFACE RMV X2INTERFACE RST ADD X2INTERFACE MOD X2INTERFACE DSP X2INTERFACE ADD X2INTERFACE MOD X2INTERFACE DSP ADD X2INTERFACE MOD X2INTERFACE DSP X2INTERFACE

X2BlackWhiteList

X2ListType

X2 Black or White List Type

eNodeB

X2Interface

X2InterfaceId

X2Interface ID

eNodeB

X2Interface

X2SctpLinkId

X2 SCTP link ID

eNodeB

X2Interface

CnOperatorId

CN Operator ID

eNodeB

X2Interface

TargetENodeBRele Target eNodeB ase release

eNodeB

X2Interface

NoAutoRmvFlag

Automatic removal flag

eNodeB

ADD X2INTERFACE MOD X2INTERFACE DSP X2INTERFACE

X2Interface

NbrENodeBId

Neighbor eNodeB ID

eNodeB

DSP X2INTERFACE

X2Interface

NbrENodeBPlmnId

Neighbor eNodeB PLMN ID

eNodeB

DSP X2INTERFACE

X2Interface

X2InterfaceState

X2Interface state

eNodeB

DSP X2INTERFACE

X2Interface

X2AbnormalReason

X2Interface state abnormal reason

eNodeB

DSP X2INTERFACE

Drx

DrxAlgSwitch

DRX switch

eNodeB

MOD DRX LST DRX

Drx

ShortDrxSwitch

Short-cycle DRX switch

eNodeB

MOD DRX LST DRX

Drx

LongDrxCycleSpeci Special long DRX al cycle

eNodeB

MOD DRX LST DRX

Drx

OnDurationTimerSp Special On Duration eNodeB ecial timer

MOD DRX LST DRX

Drx

DrxInactivityTimerS Special DRX pecial inactivity timer

eNodeB

MOD DRX LST DRX

Drx

Special short-cycle SupportShortDrxSp DRX supported eNodeB ecial indication

MOD DRX LST DRX

Drx

ShortDrxCycleSpeci Special short DRX al cycle

eNodeB

MOD DRX LST DRX

Drx

DrxShortCycleTimer Special DRX short Special cycle timer

eNodeB

MOD DRX LST DRX

Drx

LongDrxCycleForAn Long DRX Cycle for eNodeB r ANR

MOD DRX LST DRX

Drx

LongDRXCycleforIR Long DRX Cycle for eNodeB atAnr Inter-RAT ANR

MOD DRX LST DRX

ExtendedQci

ExtendedQci

Extended QoS Class Identifier

eNodeB

ADD EXTENDEDQCI LST EXTENDEDQCI MOD EXTENDEDQCI RMV EXTENDEDQCI

ExtendedQci

ServiceType

Service type

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

UlschPriorityFactor

Uplink scheduling priority factor

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

Downlink DlschPriorityFactor scheduling priority factor

eNodeB

ExtendedQci

UlMinGbr

Uplink MinGBR

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

DlMinGbr

Downlink MinGBR

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

PreAllocationWeigh Pre-allocation t weight

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

InterRatPolicyCfgGr InterRAT policy oupId config group ID

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

PrioritisedBitRate

Prioritised bit rate

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

LogicalChannelPrior Logical channel ity priority

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

RlcPdcpParaGroupI RLC PDCP eNodeB d parameter group ID

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

ExtendedQci

FreeUserFlag

Free user flag

eNodeB

ExtendedQci

FlowCtrlType

Flow Control Type

eNodeB

ADD EXTENDEDQCI MOD EXTENDEDQCI LST EXTENDEDQCI

InterRatPolicyCfgGr InterRAT policy InterRatPolicyCfgGroup oupId config group ID

eNodeB

ADD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP RMV INTERRATPOLICY CFGGROUP

InterRatPolicyCfgGroup UtranHoCfg

UTRAN handover eNodeB policy Configuration

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

InterRatPolicyCfgGroup GeranGsmHoCfg

GERAN GSM handover policy Configuration

eNodeB

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

GERAN GPRS GeranGprsEdgeHo InterRatPolicyCfgGroup EDGE handover eNodeB Cfg policy Configuration

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

InterRatPolicyCfgGroup Cdma1xRttHoCfg

CDMA2000 1XRTT handover policy eNodeB Configuration

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

InterRatPolicyCfgGroup CdmaHrpdHoCfg

CDMA2000 HRPD handover policy Configuration

eNodeB

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

InterRatPolicyCfgGroup NoHoFlag

No handover flag

eNodeB

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

InterRatPolicyCfgGroup NoFastAnrFlag

No fast ANR flag

eNodeB

ADD INTERRATPOLICY CFGGROUP MOD INTERRATPOLICY CFGGROUP LST INTERRATPOLICY CFGGROUP

PuschParam

Delta Offset CQI DeltaOffsetCqiIndex Index

eNodeB

MOD PUSCHPARAM LST PUSCHPARAM

PuschParam

Delta Offset RI DeltaOffsetRiIndex Index

eNodeB

MOD PUSCHPARAM LST PUSCHPARAM

PuschParam

DeltaOffsetAckInde Delta Offset eNodeB x Acknowledge Index

MOD PUSCHPARAM LST PUSCHPARAM

RlcPdcpParaGroup

RlcPdcpParaGroupI RLC PDCP eNodeB d parameter group ID

ADD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP RMV RLCPDCPPARAG ROUP

RlcPdcpParaGroup DiscardTimer

Discard timer

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup RlcMode

RLC-UM or RLCAM mode

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

UeMaxRetxThresho MaxretxThreshold ld for UE

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

ENodeBMaxRetxTh MaxRetxThreshold reshold for eNodeB

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup UePollByte

PollByte for UE

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup ENodeBPollByte

PollByte for eNodeB eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup UePollPdu

PollPdu for UE

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup ENodeBPollPdu

PollPdu for eNodeB eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

UePollRetransmitTi Poll retransmit timer eNodeB mer for UE

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

ENodeBPollRetrans Poll retransmit timer eNodeB mitTimer for eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

UeStatusProhibitTi mer

Status prohibit timer eNodeB for UE

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

ENodeBStatusProhi Status prohibit timer eNodeB bitTimer for eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

UeAmReorderingTi AM reordering timer eNodeB mer for UE

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

ENodeBAmReorder AM reordering timer eNodeB ingTimer for eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup PdcpSnSize

UM PDCP-SN size eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup UlRlcSnSize

Uplink RLC-Sn size eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup DlRlcSnSize

Downlink RLC-SN size

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

UeUmReorderingTi UM reordering timer eNodeB mer for UE

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

RlcPdcpParaGroup

ENodeBUmReorder UM reordering timer eNodeB ingTimer for eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

AM PDCP status RlcPdcpParaGroup PdcpStatusRptReq report required indication

eNodeB

ADD RLCPDCPPARAG ROUP MOD RLCPDCPPARAG ROUP LST RLCPDCPPARAG ROUP

StandardQci

Qci

QoS Class Indication

eNodeB

LST STANDARDQCI MOD STANDARDQCI

StandardQci

UlschPriorityFactor Ulsch priority factor eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

DlschPriorityFactor Dlsch priority factor eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

UlMinGbr

Uplink MinGBR

eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

DlMinGbr

Downlink MinGBR

eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

PreAllocationWeigh Pre-allocation t weight

eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

InterRatPolicyCfgGr InterRAT policy oupId config group ID

eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

RlcPdcpParaGroupI RLC PDCP eNodeB d parameter group ID

MOD STANDARDQCI LST STANDARDQCI

StandardQci

PrioritisedBitRate

Prioritised bit rate

eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

LogicalChannelPrior Logical channel ity priority

eNodeB

MOD STANDARDQCI LST STANDARDQCI

StandardQci

FlowCtrlType

Flow control type

eNodeB

MOD STANDARDQCI LST STANDARDQCI

AlgoDefaultPara

DefDopplerLevel

Default doppler level

eNodeB

MOD ALGODEFAULTPA RA LST ALGODEFAULTPA RA

BfMimoAdaptiveSwi BfMIMO adaptive BfMimoAdaptiveParaCfg tch switch

eNodeB

MOD BFMIMOADAPTIVE PARACFG LST BFMIMOADAPTIVE PARACFG

BfMimoAdaptiveParaCfg FixedBfMimoMode

Fixed BfMIMO mode

eNodeB

MOD BFMIMOADAPTIVE PARACFG LST BFMIMOADAPTIVE PARACFG

CqiAdaptiveCfg

CqiPeriodAdaptive

CQI period adaptive eNodeB switch

MOD CQIADAPTIVECFG LST CQIADAPTIVECFG

CqiAdaptiveCfg

UserCqiPeriodCfg

User CQI period config

eNodeB

MOD CQIADAPTIVECFG LST CQIADAPTIVECFG

MimoAdaptiveSwitc MIMO adaptive MimoAdaptiveParaCfg h switch

eNodeB

MOD MIMOADAPTIVEP ARACFG LST MIMOADAPTIVEP ARACFG

MimoAdaptiveParaCfg FixedMimoMode

Fixed MIMO mode

eNodeB

MOD MIMOADAPTIVEP ARACFG LST MIMOADAPTIVEP ARACFG

SrsAdaptiveCfg

SrsPeriodAdaptive

SRS period adaptive switch

eNodeB

MOD SRSADAPTIVECF G LST SRSADAPTIVECF G

SrsAdaptiveCfg

UserSrsPeriodCfg

User SRS period config

eNodeB

MOD SRSADAPTIVECF G LST SRSADAPTIVECF G

TypDrbBsr

Qci

QoS Class Identifier eNodeB

LST TYPDRBBSR MOD TYPDRBBSR

TypDrbBsr

TPerodicBSRTimer Periodic BSR Timer eNodeB

MOD TYPDRBBSR LST TYPDRBBSR

TypDrbBsr

RetxBsrTimer

BSR Retransmission Timer

eNodeB

MOD TYPDRBBSR LST TYPDRBBSR

HoMeasComm

GapPatternType

GAP measurement eNodeB pattern

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

EutranFilterCoeffRs EUTRAN RSRP rp filter coefficient

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

EutranFilterCoeffRs EUTRAN RSRQ rq filter coefficient

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

GeranFilterCoeff

GERAN filter coefficient

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

SMeasureInd

SMeasureInd

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

SMeasure

SMeasure

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

SpeedDepParaInd

SpeedDependInd

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

TcrMaxConnMode

TCRmax in connected mode

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

TcrMaxHystConnM TCRmaxHyst in ode connected mode

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

NcrMediumConnMo NCR Medium in de connected mode

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

NCR High in NcrHighConnMode connected mode

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

TttSfMedium

TTT Scaling factor for Medium mobility eNodeB state in connected mode

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

TttSfHigh

TTT Scaling factor for High mobility state in connected mode

eNodeB

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

UtranFilterCoeffRsc UTRAN RSCP filter eNodeB p coefficient

MOD HOMEASCOMM LST HOMEASCOMM

HoMeasComm

UtranFilterCoeffEcn UTRAN ECN0 filter eNodeB 0 coefficient

MOD HOMEASCOMM LST HOMEASCOMM

InterRatHoComm

InterRatHoMaxRprt Max report cell Cell number

eNodeB

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

InterRatHoRprtAmo Measurement report eNodeB unt amount

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

Geran InterRatHoGeranRp measurement report eNodeB rtInterval interval

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

InterRatHoUtranB1 Utran measurement eNodeB MeasQuan trigger quantity

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

UTRAN FDD InterRatHoUtranRpr measurement report eNodeB tInterval interval

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

CDMA20001XRTT InterRatHoCdma1x measurement RttB1MeasQuan trigger quantity

eNodeB

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

CDMA20001XRTT InterRatCdma1xRtt measurement report eNodeB RprtInterval interval

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

CDMA2000HRPD InterRatHoCdmaHr measurement pdB1MeasQuan trigger quantity

eNodeB

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

CDMA2000HRPD InterRatCdmaHrpd measurement report eNodeB RprtInterval interval

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

InterRat A1A2 InterRatHoA1A2Trig measurement Quan trigger quantity

eNodeB

MOD INTERRATHOCOM M LST INTERRATHOCOM M

InterRatHoComm

InterRatHoEventTy Inter RAT HO eNodeB pe Trigger Event Type

MOD INTERRATHOCOM M LST INTERRATHOCOM M

IntraRatHoComm

IntraRatHoMaxRprt Max report cell Cell number

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

IntraRatHoRprtAmo Measurement report eNodeB unt amount

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

IntraFreqHoA3Trig Quan

A3 measurement trigger quantity

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

IntraFreqHoA3Rprt A3 measurement Quan report quantity

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

IntraFreqHoRprtInte A3 measurement rval report interval

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

InterFreqHoA4Rprt Measurement A4 Quan report quantity

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

Interfreq InterFreqHoRprtInte measurement report eNodeB rval interval

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

InterFreq A1A2 InterFreqHoA1A2Tri Measurement gQuan trigger quantity

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

A1A2 Measurement FreqPriInterFreqHo trigger quantity of eNodeB A1TrigQuan Freq Priority

MOD INTRARATHOCOM M LST INTRARATHOCOM M

IntraRatHoComm

InterFreqHoA4Trig Quan

FreqPrior loadBased A4 Measurement trigger quantity

eNodeB

MOD INTRARATHOCOM M LST INTRARATHOCOM M

CSFallBackHo

LocalCellId

Local cell ID

eNodeB

LST CSFALLBACKHO MOD CSFALLBACKHO

CSFallBackHo

CSFB Utran CsfbHoUtranTimeT EventB1 Time To oTrig Trig

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CSFallBackHo

CSFB Geran CsfbHoGeranTimeT EventB1 Time To oTrig Trig

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CSFallBackHo

CSFB CDMA CsfbHoCdmaTimeT EventB1 Time To oTrig Trig

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CSFallBackHo

CSFB UTRAN CsfbHoUtranB1Thd EventB1 RSCP Rscp Trigger Threshold

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CSFallBackHo

CSFB UTRAN CsfbHoUtranB1Thd EventB1 ECN0 Ecn0 Trigger Threshold

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CSFallBackHo

CSFB GERAN CsfbHoGeranB1Th EventB1 Trigger d Threshold

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CSFallBackHo

CSFB CDMA2000 CsfbHoCdmaB1Thd EventB1 Trigger Ps Threshold

eNodeB

MOD CSFALLBACKHO LST CSFALLBACKHO

CellAcBar

LocalCellId

Local cell ID

eNodeB

LST CELLACBAR MOD CELLACBAR

CellAcBar

AC barring AcBarringInfoCfgIn information d configure indicator

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AcBarringForEmerg Emergency call ency barring state

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC barring for AcBarringForMoDat mobile data aCfgInd configure indicator

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

Access probability AcBarringFactorFor factor for originating eNodeB Call call

MOD CELLACBAR LST CELLACBAR

CellAcBar

AcBarTimeForCall

Mean access barring time for originating call

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC11BarforCall

AC11 barring state for originating call

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC12BarforCall

AC12 barring state for originating call

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC13BarforCall

AC13 barring state for originating call

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC14BarforCall

AC14 barring state for originating call

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC15BarforCall

AC15 barring state for originating call

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC barring for AcBarringForMoSig mobile signal CfgInd configure indicator

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AcBarringFactorFor Access probability Sig factor for signaling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AcBarTimeForSig

Mean access barring time for signaling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC11BarForSig

AC11 barring state for signaling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC12BarForSig

AC12 barring state for signaling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC13BarForSig

AC13 barring state for signalling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC14BarForSig

AC14 barring state for signalling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAcBar

AC15BarForSig

AC15 barring state for signaling

eNodeB

MOD CELLACBAR LST CELLACBAR

CellAccess

LocalCellId

Local cell ID

eNodeB

LST CELLACCESS MOD CELLACCESS

CellAccess

CellBarred

Cell barring state

eNodeB

MOD CELLACCESS LST CELLACCESS

CellAccess

CellReservedExt

Cell reserved for extension

eNodeB

MOD CELLACCESS LST CELLACCESS

CellAccess

IntraFreqResel

Intra-frequency reselection indication

eNodeB

MOD CELLACCESS LST CELLACCESS

CellAccess

BroadcastMode

Plmn Broadcast Mode

eNodeB

MOD CELLACCESS LST CELLACCESS

CellAccess

RoundPeriod

Plmn Round Broadcast Period

eNodeB

MOD CELLACCESS LST CELLACCESS

CellOp

LocalCellId

Local cell ID

eNodeB

ADD CELLOP DSP CELLBROADCAST CNOPERATOR LST CELLOP MOD CELLOP RMV CELLOP

CellOp

TrackingAreaId

Tracking area ID

eNodeB

ADD CELLOP LST CELLOP MOD CELLOP RMV CELLOP

CellOp

CellReservedForOp

Cell reserved for operator

eNodeB

ADD CELLOP MOD CELLOP LST CELLOP

CellOp

OpUlRbUsedRatio

Operator uplink RB eNodeB used ratio

ADD CELLOP MOD CELLOP LST CELLOP

CellOp

OpDlRbUsedRatio

Operator downlink RB used ratio

eNodeB

ADD CELLOP MOD CELLOP LST CELLOP

CellOp

BroadcastCnOperat Broadcast CN orId operator ID

eNodeB

DSP CELLBROADCAST CNOPERATOR

CellResel

LocalCellId

Local cell ID

eNodeB

LST CELLRESEL MOD CELLRESEL

CellResel

Qhyst

Hysteresis value for eNodeB ranking criteria

MOD CELLRESEL LST CELLRESEL

CellResel

Speed-dependent SpeedDepReselCfg reselection eNodeB Ind parameter configure indicator

MOD CELLRESEL LST CELLRESEL

CellResel

TEvaluation

The duration for evaluating criteria to eNodeB enter mobility states

MOD CELLRESEL LST CELLRESEL

CellResel

THystNormal

The additional duration for evaluating criteria to eNodeB enter normal mobility state

MOD CELLRESEL LST CELLRESEL

CellResel

The number of cell NCellChangeMediu changes to enter m medium mobility state

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

NCellChangeHigh

The number of cell changes to enter high mobility state

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

QHystSfMedium

Additional hysteresis applied in medium mobility state to q-Hyst

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

QHystSfHigh

Additional hysteresis applied in high mobility state to q-Hyst

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

Threshold for EUTRAN interSNonIntraSearchCf frequency and inter- eNodeB gInd RAT measurements configure indicator

MOD CELLRESEL LST CELLRESEL

CellResel

SNonIntraSearch

Threshold for EUTRAN intereNodeB frequency and interRAT measurements

MOD CELLRESEL LST CELLRESEL

CellResel

ThrshServLow

Serving frequency lower priority threshold

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

CellReselPriority

Cell reselection priority

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

QRxLevMin

Minimum required RX level

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

PMaxCfgInd

Ue max power allowed configure indicator

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

PMax

Max transmit power eNodeB allowed

MOD CELLRESEL LST CELLRESEL

CellResel

Threshold for intra frequency SIntraSearchCfgInd measurements configure indicator

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

SIntraSearch

Threshold for intra frequency measurements

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

Measurement MeasBandWidthCfg bandwidth configure eNodeB Ind indicator

MOD CELLRESEL LST CELLRESEL

CellResel

MeasBandWidth

Measurement bandwidth

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

TReselEutran

Cell reselection timer value for EUTRAN

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

Speed state scale SpeedStateSfCfgIn factor configure d indicator

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

Scaling factor of TReselEutranSfMe TReselEutra in dium medium mobility state

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

Scaling factor of TReselEutranSfHig TReselEutra in high eNodeB h mobility state

MOD CELLRESEL LST CELLRESEL

CellResel

NeighCellConfig

Neighbor cell config eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

PresenceAntennaP Presence antenna ort1 port1

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

SIntraSearchQ

RSRQ Threshold for intra frequency measurements

eNodeB

MOD CELLRESEL LST CELLRESEL

CellResel

RSRQ Threshold for EUTRAN interSNonIntraSearchQ eNodeB frequency and interRAT measurements

MOD CELLRESEL LST CELLRESEL

CellResel

Serving frequency ThrshServLowQCfg lower priority RSRQ eNodeB Ind threshold configure indicator

MOD CELLRESEL LST CELLRESEL

CellResel

ThrshServLowQ

Serving frequency lower priority RSRQ eNodeB threshold

MOD CELLRESEL LST CELLRESEL

CellResel

QQualMinCfgInd

Minimum intrafrequency reselection required eNodeB quality level configure indicator

MOD CELLRESEL LST CELLRESEL

CellResel

QQualMin

Minimum intrafrequency eNodeB reselection required quality level

MOD CELLRESEL LST CELLRESEL

CellReselCdma2000 LocalCellId

Local cell ID

eNodeB

ADD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 RMV CELLRESELCDMA 2000 ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 SysTimeCfgInd

System time information configure indicator

eNodeB

CellReselCdma2000 CdmaEutraSyn

CDMA and EUTRA network eNodeB synchronised indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

CDMA search SearchWndSizeCfg window size Ind configure indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 SearchWndSize

Search window size eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 HrpdParamCfgInd

HRPD parameters configure indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HRPD cell HrpdCellReselectPa reselection ramCfgInd configure indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HrpdPreRegistAllow HRPD pre-regist ed allowed indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HrpdPreRegistZone HRPD pre-regist Id zone ID

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HRPD second preHrpdSecondPreReg regist zone 0 eNodeB istZoneId0Ind configure indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HrpdSecPreRegistZ HRPD secondary eNodeB oneId0 pre-regist zone ID 0

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HRPD second preHrpdSecondPreReg regist zone 1 eNodeB istZoneId1Ind configure indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

HrpdSecPreRegistZ HRPD secondary eNodeB oneId1 pre-regist zone ID 1

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 TreselectionHrpd

Cell reselection timer for HRPD

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Speed state scale SpeedStateSfCfgIn factor configure d indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

Scaling factor of TReselCdmaHrpdSf TReselCdmaHrpd CellReselCdma2000 High in high mobility state

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

Scaling factor of TReselCdmaHrpdSf TReselCdmaHrpd CellReselCdma2000 Medium in medium mobility state

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 Cdma1XrttCfgInd

1XRTT parameters eNodeB configure indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

1XRTT csfbCdma1XrttCsfbReg registration CellReselCdma2000 CfgInd parameters configure indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT system ID Sid

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT network ID Nid

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT multiple Cdma1XrttCsfbReg system ID storage MultiSidInd indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT multiple Cdma1XrttCsfbReg network ID storage MultiNidInd indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT home eNodeB HomeRegInd registration indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT system ID Cdma1XrttCsfbReg roamer registration FrgnSidRegInd indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT network ID Cdma1XrttCsfbReg roamer registration FrgnNidRegInd indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT parameter Cdma1XrttCsfbReg change registration eNodeB ParamRegInd indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT power up eNodeB PowerUpRegInd registration indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT registration eNodeB RegPeriod period

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT registration eNodeB RegZone zone

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT number of Cdma1XrttCsfbReg registration zones to eNodeB TotalZone be retained

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttCsfbReg 1XRTT zone timer ZoneTimer length

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

1XRTT state of long Cdma1XrttLongCod code generation CellReselCdma2000 eNodeB eStateCfgInd registers configure indicatorr

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT state of long Cdma1XrttLongCod code generation eNodeB eState registers

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT cell Cdma1XrttCellRese reselection lCfgInd configure indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttTreselect Cell reselection ion timer for 1XRTT

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT speed state Cdma1XrttSpeedSt scale factors eNodeB ateCfgInd configure indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

Cdma1XrttSfMediu 1XRTT medium m speed scale factor

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 Cdma1XrttSfHigh

1XRTT high speed scale factor

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000

1XRTT power-down CsfbRegPwrDownR registration indicator eNodeB egCfgInd configure indicator

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBarCfgInd

1XRTT AC barring information configure indicator

eNodeB

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar0to9

Persistence value for access overload eNodeB classes 0 to 9

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar10

Persistence value for access overload eNodeB class 10

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar11

Persistence value for access overload eNodeB class 11

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar12

Persistence value for access overload eNodeB class 12

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar13

Persistence value for access overload eNodeB class 13

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar14

Persistence value for access overload eNodeB class 14

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBar15

Persistence value for access overload eNodeB class 15

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBarMsg

Persistence modifier for access barring factor for eNodeB message transmissions

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBarReg

Persistence modifier for access barring factor for eNodeB autonomous registrations

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselCdma2000 CsfbAcBarEmg

Persistence value for emergency calls and emergency message eNodeB transmissions for access overload classes 0 to 9

ADD CELLRESELCDMA 2000 MOD CELLRESELCDMA 2000 LST CELLRESELCDMA 2000

CellReselGeran

LocalCellId

Local cell ID

eNodeB

ADD CELLRESELGERA N LST CELLRESELGERA N MOD CELLRESELGERA N RMV CELLRESELGERA N

CellReselGeran

TReselGeran

Cell reselection timer value for GERAN

eNodeB

ADD CELLRESELGERA N MOD CELLRESELGERA N LST CELLRESELGERA N

CellReselGeran

Speed state scale SpeedStateSfCfgIn factor configure d indicator

eNodeB

ADD CELLRESELGERA N MOD CELLRESELGERA N LST CELLRESELGERA N

CellReselGeran

Scaling factor of TReselGeranSfMed TReselGeran in ium medium mobility state

eNodeB

ADD CELLRESELGERA N MOD CELLRESELGERA N LST CELLRESELGERA N

CellReselGeran

Scaling factor of TReselGeranSfHigh TReselGeran in high mobility state

eNodeB

ADD CELLRESELGERA N MOD CELLRESELGERA N LST CELLRESELGERA N

CellReselUtran

LocalCellId

Local cell ID

eNodeB

ADD CELLRESELUTRA N LST CELLRESELUTRA N MOD CELLRESELUTRA N RMV CELLRESELUTRA N

CellReselUtran

TReselUtran

Cell reselection timer value for UTRAN

eNodeB

ADD CELLRESELUTRA N MOD CELLRESELUTRA N LST CELLRESELUTRA N

CellReselUtran

Speed state scale SpeedStateSfCfgIn factor configure d indicator

eNodeB

ADD CELLRESELUTRA N MOD CELLRESELUTRA N LST CELLRESELUTRA N

CellReselUtran

Scaling factor of TReselUtranSfMedi TReselUtran in um medium mobility state

eNodeB

ADD CELLRESELUTRA N MOD CELLRESELUTRA N LST CELLRESELUTRA N

CellReselUtran

Scaling factor of TReselUtranSfHigh TReselUtran in high eNodeB mobility state

ADD CELLRESELUTRA N MOD CELLRESELUTRA N LST CELLRESELUTRA N

CellSel

LocalCellId

Local cell ID

eNodeB

LST CELLSEL MOD CELLSEL

CellSel

QRxLevMin

Minimum required RX level

eNodeB

MOD CELLSEL LST CELLSEL

CellSel

QRxLevMinOffset

Minimum required RX level offset

eNodeB

MOD CELLSEL LST CELLSEL

CellSel

QQualMin

Minimum required RX quality level

eNodeB

MOD CELLSEL LST CELLSEL

CellSel

Minimum required QQualMinOffsetCfg RX quality level Ind offset configure indicator

eNodeB

MOD CELLSEL LST CELLSEL

CellSel

QQualMinOffset

Minimum required RX quality level offset

eNodeB

MOD CELLSEL LST CELLSEL

CellSiMap

LocalCellId

Local cell ID

eNodeB

LST CELLSIMAP MOD CELLSIMAP

CellSiMap

SiMapSwitch

SIB mapping SI algorithm switch

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib2Period

SIB2 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib3Period

SIB3 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib4Period

SIB4 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib5Period

SIB5 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib6Period

SIB6 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib7Period

SIB7 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib8Period

SIB8 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib10Period

SIB10 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

Sib11Period

SIB11 period

eNodeB

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

EtwsPnDuration

ETWS PN message eNodeB duration time

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

EtwsSnOverlapPoli ETWS SN message eNodeB cy overlap policy

MOD CELLSIMAP LST CELLSIMAP

CellSiMap

EtwsPnOverlapPoli ETWS PN message eNodeB cy overlap policy

MOD CELLSIMAP LST CELLSIMAP

CellUlpcComm

LocalCellId

Local cell ID

eNodeB

LST CELLULPCCOMM MOD CELLULPCCOMM

CellUlpcComm

PassLossCoeff

Path loss coefficient eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

P0NominalPUCCH P0 nominal PUCCH eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

P0NominalPUSCH P0 nominal PUSCH eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

DeltaFPUCCHForm DeltaF for PUCCH at1 format 1

eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

DeltaFPUCCHForm DeltaF for PUCCH at1b format 1b

eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

DeltaFPUCCHForm DeltaF for PUCCH at2 format 2

eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

DeltaFPUCCHForm DeltaF for PUCCH at2a format 2a

eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

DeltaFPUCCHForm DeltaF for PUCCH at2b format 2b

eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

CellUlpcComm

DeltaPreambleMsg Delta preamble 3 value for msg3

eNodeB

MOD CELLULPCCOMM LST CELLULPCCOMM

TimeAlignmentTimer LocalCellId

Local cell ID

eNodeB

LST TATIMER MOD TATIMER

TimeAlignmentTimer

TimeAlignmentTime Uplink time r alignment timer

eNodeB

MOD TATIMER LST TATIMER

UeTimerConst

LocalCellId

Local cell ID

eNodeB

LST UETIMERCONST MOD UETIMERCONST

UeTimerConst

T300

Timer 300

eNodeB

MOD UETIMERCONST LST UETIMERCONST

UeTimerConst

T301

Timer 301

eNodeB

MOD UETIMERCONST LST UETIMERCONST

UeTimerConst

T310

Timer 310

eNodeB

MOD UETIMERCONST LST UETIMERCONST

UeTimerConst

T311

Timer 311

eNodeB

MOD UETIMERCONST LST UETIMERCONST

UeTimerConst

N311

Constant N311

eNodeB

MOD UETIMERCONST LST UETIMERCONST MOD UETIMERCONST LST UETIMERCONST ACT CELL ADD CELL BLK CELL DEA CELL DSP CELL LST CELL MOD CELL RMV CELL STR CELLRFLOOPBAC K STR CELLSELFTEST UBL CELL

UeTimerConst

N310

Constant N310

eNodeB

Cell

LocalCellId

Local cell ID

eNodeB

Cell

CellName

Cell name

eNodeB

ADD CELL MOD CELL LST CELL

Cell

SectorId

Sector No.

eNodeB

ADD CELL MOD CELL LST CELL

Cell

CsgInd

Csg indicator

eNodeB

ADD CELL MOD CELL LST CELL

Cell

UlCyclicPrefix

Uplink cyclic prefix length

eNodeB

ADD CELL MOD CELL LST CELL

Cell

DlCyclicPrefix

Downlink cyclic prefix length

eNodeB

ADD CELL MOD CELL LST CELL

Cell

FreqBand

Frequency band

eNodeB

ADD CELL MOD CELL LST CELL

Cell

UlEarfcnCfgInd

Uplink earfcn indication

eNodeB

ADD CELL MOD CELL LST CELL

Cell

UlEarfcn

Uplink earfcn

eNodeB

ADD CELL MOD CELL LST CELL

Cell

DlEarfcn

Downlink earfcn

eNodeB

ADD CELL MOD CELL LST CELL

Cell

UlBandWidth

Uplink bandwidth

eNodeB

ADD CELL MOD CELL LST CELL

Cell

DlBandWidth

Downlink bandwidth eNodeB

ADD CELL MOD CELL LST CELL

Cell

CellId

Cell ID

eNodeB

ADD CELL MOD CELL LST CELL

Cell

PhyCellId

Physical cell ID

eNodeB

ADD CELL MOD CELL LST CELL

Cell

AdditionalSpectrum Additional spectrum eNodeB Emission emission

ADD CELL MOD CELL LST CELL

Cell

CellActiveState

Cell active state

eNodeB

LST CELL

Cell

CellAdminState

Cell admin state

eNodeB

BLK CELL LST CELL

Cell

CellMidBlkTimer

Cell middle block timer

eNodeB

BLK CELL LST CELL

Cell

FddTddInd

Cell FDD TDD indication

eNodeB

ADD CELL MOD CELL LST CELL

Cell

SubframeAssignme Subframe nt assignment

eNodeB

ADD CELL MOD CELL LST CELL

Cell

SpecialSubframePa Special subframe tterns patterns

eNodeB

ADD CELL MOD CELL LST CELL

Cell

CellSpecificOffset

Cell specific offset

eNodeB

ADD CELL MOD CELL LST CELL

Cell

QoffsetFreq

Intra frequency offset

eNodeB

ADD CELL MOD CELL LST CELL

Cell

RootSequenceIdx

Root sequence index

eNodeB

ADD CELL MOD CELL LST CELL

Cell

HighSpeedFlag

High speed flag

eNodeB

ADD CELL MOD CELL LST CELL

Cell

PreambleFmt

Preamble format

eNodeB

ADD CELL MOD CELL LST CELL

Cell

CellRadius

Cell radius

eNodeB

ADD CELL MOD CELL LST CELL

Cell

Customized CustomizedBandWi bandwidth configure eNodeB dthCfgInd indicator

ADD CELL MOD CELL LST CELL

Cell

CustomizedULBand Customized uplink Width bandwidth

eNodeB

ADD CELL MOD CELL LST CELL

Cell

CustomizedDLBand Customized eNodeB Width downlink bandwidth

ADD CELL MOD CELL LST CELL

Cell

EmergencyAreaIdCf Emergency Area Id eNodeB gInd indicator

ADD CELL MOD CELL LST CELL

Cell

EmergencyAreaId

Emergency Area ID eNodeB

ADD CELL MOD CELL LST CELL

Cell

Ue max power UePowerMaxCfgInd allowed configure indicator

eNodeB

ADD CELL MOD CELL LST CELL

Cell

UePowerMax

Max transmit power eNodeB allowed

ADD CELL MOD CELL LST CELL

Cell

MultiRruCellFlag

Flag of Multi-RRU Cell

eNodeB

ADD CELL MOD CELL LST CELL

Cell

MultiRruCellMode

Mode of Multi-RRU eNodeB Cell

ADD CELL MOD CELL LST CELL

Cell

CPRICompression

CPRI Compression eNodeB

ADD CELL MOD CELL LST CELL

Cell

CellState

Cell instance state

eNodeB

DSP CELL

Cell

CellLatestAvailState

Reason For Latest State Change

eNodeB

DSP CELL

Cell

CellLatestSetupTim Cell latest setup e time

eNodeB

DSP CELL

Cell

CellLatestSetupTyp Cell latest setup e operate type

eNodeB

DSP CELL

Cell

CellLatestRemoveT Cell latest remove ime time

eNodeB

DSP CELL

Cell

CellLatestRemoveT Cell latest remove ype operate type

eNodeB

DSP CELL

Cell

CellPowerSaveStat Cell power save e state

eNodeB

DSP CELL

Cell

BbiSlot

Bbi slot

eNodeB

DSP CELL

Cell

CellTopoType

Cell topo type

eNodeB

DSP CELL

Cell

CabinetNo

Cabinet number

eNodeB

DSP CELL

Cell

SubrackNo

Subrack number

eNodeB

DSP CELL

Cell

SlotNo

Slot number

eNodeB

DSP CELL

Cell

SymbolShutdownSt Symbol shutdown ate state

eNodeB

DSP CELL

Cell

MaxTxPower

Maximum transmit power

eNodeB

DSP CELL

CellBf

LocalCellId

Local cell ID

eNodeB

LST CELLBF MOD CELLBF

CellBf

MaxBfRankPara

Beamforming maximum number of layers

eNodeB

MOD CELLBF LST CELLBF

CellDLIcicMcPara

LocalCellId

Local cell ID

eNodeB

LST CELLDLICICMCPA RA MOD CELLDLICICMCPA RA

CellDLIcicMcPara

ReportInterval

Downlink ICIC measurement report eNodeB interval

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

Downlink ICIC MaxReportCellNum measurement max report cell number

eNodeB

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

ReportAmount

DownLink ICIC measurement report eNodeB amount

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

ReportQuantity

DownLink ICIC measurement report eNodeB quantity

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

TriggerQuantity

DownLink ICIC measurement trigger quantity

eNodeB

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

Hysteresis

DownLink ICIC measurement hysteresis

eNodeB

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

TimeToTrigger

DownLink ICIC measurement time to trigger

eNodeB

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellDLIcicMcPara

A3Offset

Downlink ICIC A3 offset

eNodeB

MOD CELLDLICICMCPA RA LST CELLDLICICMCPA RA

CellLowPower

LocalCellId

Local cell ID

eNodeB

LST CELLLOWPOWER MOD CELLLOWPOWER

CellLowPower

LowPwrSwitch

Low power consumption mode eNodeB switch

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

LowPwrOrder

Low power consumption mode eNodeB order

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

StartTime

Start time

eNodeB

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

StopTime

Stop time

eNodeB

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

CellUsedPwrReduc Cell used power eTimeLen reduce time length

eNodeB

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

Reference signal RsPwrReduceTime power reduce time Len length

eNodeB

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

RfShutDownTimeLe RF shutdown time n length

eNodeB

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

CellUsedPwrRatio

Cell used power ratio

eNodeB

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

RsPwrAdjOffset

Reference signal eNodeB power adjust offset

MOD CELLLOWPOWER LST CELLLOWPOWER

CellLowPower

EnterTimeLen

Time length for entering the low eNodeB power consumption mode

MOD CELLLOWPOWER LST CELLLOWPOWER

CellMro

LocalCellId

Local cell ID

eNodeB

LST CELLMRO MOD CELLMRO

CellMro

CioAdjLimitCfgInd

CIO adjustment range configuration eNodeB indicator

MOD CELLMRO LST CELLMRO

CellMro

CioAdjUpperLimit

CIO adjustment upper limit

eNodeB

MOD CELLMRO LST CELLMRO

CellMro

CioAdjLowerLimit

CIO adjustment lower limit

eNodeB

MOD CELLMRO LST CELLMRO

CellRacThd

LocalCellId

Local cell ID

eNodeB

LST CELLRACTHD MOD CELLRACTHD

CellRacThd

GoldServiceArpThd

Gold service arp threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

SilverServiceArpTh Silver service arp d threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci1HoThd

QCI1 handover eNodeB admission threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci2HoThd

QCI2 handover eNodeB admission threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci3HoThd

QCI3 handover eNodeB admission threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci4HoThd

QCI4 handover eNodeB admission threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Gold new service NewGoldServiceOff admission threshold eNodeB set offset

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Silver new service NewSilverServiceOf admission threshold eNodeB fset offset

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Bronze new service NewCopperService admission threshold eNodeB Offset offset

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci1CongThd

QCI1 congest threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci2CongThd

QCI2 congest threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci3CongThd

QCI3 congest threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Qci4CongThd

QCI4 congest threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Gold-level GBR GoldGbrCongPropo service congest rtion scheduler proportion

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Silver-level GBR SilverGbrCongProp service congest ortion scheduler proportion

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

Bronze-level GBR CopperGbrCongPro service congest portion scheduler proportion

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

GBR used resource GbrRbUsedHighTh high proportion eNodeB d threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

GBR used resource GbrRbUsedLowThd low proportion eNodeB threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

LdcMeaArpThd

ARP threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

CongRelOffset

Offset for service congest relieving

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

PreemptionArpThd

Preemption ARP threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

UlRbHighThd

Uplink RB used eNodeB ratio high threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

DlRbHighThd

Downlink RB used eNodeB ratio high threshold

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

UlRbLowThd

Uplink RB used ratio low threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

DlRbLowThd

Downlink RB used ratio low threshold

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRacThd

MaxNonGbrBearer Num

Non-GBR max bearer number

eNodeB

MOD CELLRACTHD LST CELLRACTHD

CellRfShutdown

LocalCellId

Local cell ID

eNodeB

LST CELLRFSHUTDO WN MOD CELLRFSHUTDO WN

CellRfShutdown

RfShutdownSwitch

RF intelligent shutdown switch

eNodeB

MOD CELLRFSHUTDO WN LST CELLRFSHUTDO WN

CellRfShutdown

StartTime

Start time

eNodeB

MOD CELLRFSHUTDO WN LST CELLRFSHUTDO WN

CellRfShutdown

StopTime

Stop time

eNodeB

MOD CELLRFSHUTDO WN LST CELLRFSHUTDO WN

CellRfShutdown

RsPwrAdjOffset

Reference signal eNodeB power adjust offset

MOD CELLRFSHUTDO WN LST CELLRFSHUTDO WN

CellRicAlgo

LocalCellId

Local cell ID

eNodeB

GET CELLRICDATA LST CELLRICALGO MOD CELLRICALGO SND

CellRicAlgo

RicAlgoSwitch

RIC algorithm switch

eNodeB

MOD CELLRICALGO LST CELLRICALGO

CellRicAlgo

MuteUpPTSSymNu Mute UpPTS m Symbol Number

eNodeB

MOD CELLRICALGO LST CELLRICALGO

CellRicAlgo

MuteULSym

Whether to mute UL eNodeB symbol

MOD CELLRICALGO LST CELLRICALGO LST CELLSHUTDOWN MOD CELLSHUTDOWN

CellShutdown

LocalCellId

Local cell ID

eNodeB

CellShutdown

CellShutdownSwitc Cell intelligent h shutdown switch

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellShutdown

StartTime

Start time

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellShutdown

StopTime

Stop time

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellShutdown

DlPrbThd

Downlink PRB threshold

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellShutdown

DlPrbOffset

Downlink PRB offset

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellShutdown

UlPrbThd

Uplink PRB threshold

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellShutdown

UlPrbOffset

Uplink PRB offset

eNodeB

MOD CELLSHUTDOWN LST CELLSHUTDOWN

CellULIcicMcPara

LocalCellId

Local cell ID

eNodeB

LST CELLULICICMCPA RA MOD CELLULICICMCPA RA

CellULIcicMcPara

ReportInterval

Uplink ICIC measurement report eNodeB interval

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

Uplink ICIC MaxReportCellNum measurement max report cell number

eNodeB

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

ReportAmount

Uplink ICIC measurement report eNodeB amount

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

ReportQuantity

Uplink ICIC measurement report eNodeB quantity

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

TriggerQuantity

Uplink ICIC measurement trigger quantity

eNodeB

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

Hysteresis

Uplink ICIC measurement hysteresis

eNodeB

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

TimeToTrigger

Uplink ICIC measurement time to trigger

eNodeB

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellULIcicMcPara

A3Offset

Uplink ICIC A3 offset

eNodeB

MOD CELLULICICMCPA RA LST CELLULICICMCPA RA

CellUlschAlgo

LocalCellId

Local cell ID

eNodeB

LST CELLULSCHALGO MOD CELLULSCHALGO

CellUlschAlgo

UlschStrategy

Uplink Scheduling Strategy

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

AdaptHarqSwitch

adaptive HARQ switch

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

SinrAdjustTargetIbl SINR target IBLER eNodeB er adjustment

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

System Bandwidth PreAllocationBandw Ratio Used By PreeNodeB idthRatio schedule user per TTI

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

PreAllocationMinPe minimal period of riod pre-allocation

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

PreAllocationSize

data size of preallocation

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

UlHoppingType

Uplink hopping type eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

FreeUserUlRbUsed Free Users Uplink Ratio RB Ratio

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

UlSrSchDateLen

UL scheduling request user data length

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

CellUlschAlgo

SpsRelThd

Semi-persistent resource implicit release threshold

eNodeB

MOD CELLULSCHALGO LST CELLULSCHALGO

InterRatCellShutdown LocalCellId

Local cell ID

eNodeB

LST INTERRATCELLSH UTDOWN MOD INTERRATCELLSH UTDOWN

ForceShutdownSwit Force shutdown InterRatCellShutdown ch switch

eNodeB

MOD INTERRATCELLSH UTDOWN LST INTERRATCELLSH UTDOWN

InterRatCellShutdown StartTime

Start time

eNodeB

MOD INTERRATCELLSH UTDOWN LST INTERRATCELLSH UTDOWN

InterRatCellShutdown StopTime

Stop time

eNodeB

MOD INTERRATCELLSH UTDOWN LST INTERRATCELLSH UTDOWN

InterRatCellShutdown BearNumThd

Bear number threshold

eNodeB

MOD INTERRATCELLSH UTDOWN LST INTERRATCELLSH UTDOWN

InterRatCellShutdown DlPrbThd

Downlink PRB threshold

eNodeB

MOD INTERRATCELLSH UTDOWN LST INTERRATCELLSH UTDOWN

InterRatCellShutdown UlPrbThd

Uplink PRB threshold

eNodeB

MOD INTERRATCELLSH UTDOWN LST INTERRATCELLSH UTDOWN

CellAlgoSwitch

LocalCellId

Local cell ID

eNodeB

LST CELLALGOSWITC H MOD CELLALGOSWITC H

CellAlgoSwitch

RachAlgoSwitch

RACH algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

SrsAlgoSwitch

SoundingRS algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

PucchAlgoSwitch

PUCCH algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

AqmAlgoSwitch

AQM algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

CqiAdjAlgoSwitch

CQI adjust algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

RlfDetectAlgoSwitc RLF detection h algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

DynAdjVoltSwitch

Dynamic adjust voltage algorithm switch

eNodeB

CellAlgoSwitch

RacAlgoSwitch

RAC algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

MlbAlgoSwitch

Load balancing algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

DlPcAlgoSwitch

Downlink power control algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

UlPcAlgoSwitch

Uplink power control algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

BfAlgoSwitch

BF algorithm switch eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

DlSchSwitch

DL schedule switch eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

UlSchSwitch

Uplink schedule switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

RanShareModeSwit RAN Sharing Mode eNodeB ch Switch

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

Based on FreqPriorityHoSwitc Frequency Priority h HO Switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

MuBfAlgoSwitch

MUBF algorithm switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

DistBasedHoSwitch

Distance-based Handover Switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

AcBarAlgoSwitch

AcBar algorithms switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

UlCompSwitch

UlCoMP algorithms eNodeB switch

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellAlgoSwitch

MrcIrcAdptSwitch

MRC/IRC adaptation switch

eNodeB

MOD CELLALGOSWITC H LST CELLALGOSWITC H

CellDlIcic

LocalCellId

Local cell ID

eNodeB

LST CELLDLICIC MOD CELLDLICIC

CellDlIcic

BandMode

Downlink band division scheme

eNodeB

MOD CELLDLICIC LST CELLDLICIC

CellDlpcPdcch

LocalCellId

Local cell ID

eNodeB

LST CELLDLPCPDCCH MOD CELLDLPCPDCCH

CellDlpcPdcch

DediDciPwrOffset

DCI power offset for eNodeB dedicated control

MOD CELLDLPCPDCCH LST CELLDLPCPDCCH

CellDlpcPdsch

LocalCellId

Local cell ID

eNodeB

LST CELLDLPCPDSCH MOD CELLDLPCPDSCH

CellDlpcPdsch

CcuPa

Center UE PA

eNodeB

MOD CELLDLPCPDSCH LST CELLDLPCPDSCH

CellDlpcPdsch

CeuPa

Edge UE PA

eNodeB

MOD CELLDLPCPDSCH LST CELLDLPCPDSCH

CellDlpcPhich

LocalCellId

Local cell ID

eNodeB

LST CELLDLPCPHICH MOD CELLDLPCPHICH

CellDlpcPhich

PwrOffset

Phich Pc Off Power eNodeB Offset

MOD CELLDLPCPHICH LST CELLDLPCPHICH

CellDlschAlgo

LocalCellId

Local cell ID

eNodeB

LST CELLDLSCHALGO MOD CELLDLSCHALGO

CellDlschAlgo

DlschStrategy

Downlink eNodeB scheduling Strategy

MOD CELLDLSCHALGO LST CELLDLSCHALGO

CellDlschAlgo

FreeUserDlRbUsed Free Users Ratio Downlink RB Ratio

eNodeB

MOD CELLDLSCHALGO LST CELLDLSCHALGO

CellDlschAlgo

BtServiceWeight

P2P Service Weight eNodeB

MOD CELLDLSCHALGO LST CELLDLSCHALGO

CellDlschAlgo

Other Service OtherServiceWeight Weight

eNodeB

MOD CELLDLSCHALGO LST CELLDLSCHALGO

CellDlschAlgo

maximum number MaxMimoRankPara of MIMO layers

eNodeB

MOD CELLDLSCHALGO LST CELLDLSCHALGO

CellMLB

LocalCellId

Local cell ID

eNodeB

LST CELLMLB MOD CELLMLB

CellMLB

IntraFreqMlbThd

Intra-Frequency Mobility Load Balancing Threshold

eNodeB

MOD CELLMLB LST CELLMLB

CellMLB

InterFreqMlbThd

Inter-Frequency Mobility Load Balancing Threshold

eNodeB

MOD CELLMLB LST CELLMLB

CellMLB

InterRatMlbThd

Inter-RAT Mobility Load Balancing Threshold

eNodeB

MOD CELLMLB LST CELLMLB

CellMLB

LoadExchangePerio Load Information d Exchange Period

eNodeB

MOD CELLMLB LST CELLMLB

CellMLB

LoadOffset

Load Offset

eNodeB

MOD CELLMLB LST CELLMLB

CellMLB

LoadDiffThd

Load Difference Threshold

eNodeB

MOD CELLMLB LST CELLMLB

CellPdcchAlgo

LocalCellId

Local cell ID

eNodeB

LST CELLPDCCHALGO MOD CELLPDCCHALGO MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPdcchAlgo

SignalCongregateL ComSigCongregLv eNodeB evel

CellPdcchAlgo

Cce Ratio Adjust CceRatioAdjSwitch Switch

eNodeB

MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPdcchAlgo

InitPdcchSymNum

PDCCH Initial Symbol Number

eNodeB

MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPdcchAlgo

VirtualLoadPro

PDCCH Virtual eNodeB Loading Proportion

MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPdcchAlgo

PDCCH Symbol PdcchSymNumSwit Number Adjust ch Switch

eNodeB

MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPdcchAlgo

CceUseRatio

CCE use ratio

eNodeB

MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPdcchAlgo

PDCCH PdcchAggLvlCLAdj Aggregation Level ustSwitch CL Switch

eNodeB

MOD CELLPDCCHALGO LST CELLPDCCHALGO

CellPucchAlgo

LocalCellId

Local cell ID

eNodeB

LST CELLPUCCHALGO MOD CELLPUCCHALGO

CellPucchAlgo

SriLowLoadThd

SRI Low Load Threshold

eNodeB

MOD CELLPUCCHALGO LST CELLPUCCHALGO

CellNoAccessAlmPara LocalCellId

Local cell ID

eNodeB

LST CELLNOACCESSA LMPARA MOD CELLNOACCESSA LMPARA

NoAccessStartDete No access detect CellNoAccessAlmPara ctTime start time

eNodeB

MOD CELLNOACCESSA LMPARA LST CELLNOACCESSA LMPARA

NoAccessStopDete No access detect CellNoAccessAlmPara ctTime stop time

eNodeB

MOD CELLNOACCESSA LMPARA LST CELLNOACCESSA LMPARA

NoAccessDetectTi CellNoAccessAlmPara mer

No access detect timer

eNodeB

MOD CELLNOACCESSA LMPARA LST CELLNOACCESSA LMPARA

CellUlIcic

LocalCellId

Local cell ID

eNodeB

LST CELLULICIC MOD CELLULICIC

CellUlIcic

BandMode

Uplink band division eNodeB scheme

MOD CELLULICIC LST CELLULICIC

CellSimuLoad

LocalCellId

Local cell ID

eNodeB

ADD CELLSIMULOAD DSP CELLSIMULOAD LST CELLSIMULOAD MOD CELLSIMULOAD RMV CELLSIMULOAD

CellSimuLoad

SimLoadCfgIndex

Configure Index

eNodeB

ADD CELLSIMULOAD MOD CELLSIMULOAD LST CELLSIMULOAD

CellSimuLoad

SimuLoadTransMod SimuLoad eNodeB e transmission mode

ADD CELLSIMULOAD MOD CELLSIMULOAD LST CELLSIMULOAD

CellSimuLoad

SimuLoadRbNum

SimuLoad allocated eNodeB RB Number

DSP CELLSIMULOAD

CellSimuLoad

CommercRbNum

Commercial service eNodeB RB number

DSP CELLSIMULOAD

CellSimuLoad

SimuLoadPower

SimuLoad allocated eNodeB power Commercial service eNodeB power

DSP CELLSIMULOAD DSP CELLSIMULOAD

CellSimuLoad

CommercPower

CellSimuLoad

SimuLoadUserNum

SimuLoad allocated eNodeB user Number

DSP CELLSIMULOAD

CellSimuLoad

CommercUserNum

Commercial service eNodeB user number

DSP CELLSIMULOAD

BcchCfg

LocalCellId

Local cell ID

eNodeB

LST BCCHCFG MOD BCCHCFG

BcchCfg

ModifyPeriodCoeff

Modification period eNodeB coefficient

MOD BCCHCFG LST BCCHCFG

CellChPwrCfg

LocalCellId

Local cell ID

eNodeB

LST CELLCHPWRCFG MOD CELLCHPWRCFG

CellChPwrCfg

PcfichPwr

PCFICH power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG

CellChPwrCfg

PbchPwr

PBCH power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG

CellChPwrCfg

SchPwr

SCH power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG

CellChPwrCfg

DbchPwr

DBCH power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG

CellChPwrCfg

PchPwr

PCH power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG

CellChPwrCfg

RaRspPwr

Rach response power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG

CellChPwrCfg

PrsPwr

Prs power

eNodeB

MOD CELLCHPWRCFG LST CELLCHPWRCFG LST PDSCHCFG MOD PDSCHCFG

PDSCHCfg

LocalCellId

Local cell ID

eNodeB

PDSCHCfg

ReferenceSignalPw Reference signal r power

eNodeB

MOD PDSCHCFG LST PDSCHCFG

PDSCHCfg

Pb

PB

eNodeB

MOD PDSCHCFG LST PDSCHCFG

RACHCfg

LocalCellId

Local cell ID

eNodeB

LST RACHCFG MOD RACHCFG

RACHCfg

PwrRampingStep

Power ramping step eNodeB

MOD RACHCFG LST RACHCFG

RACHCfg

Preamble initial PreambInitRcvTarg received target etPwr power

eNodeB

MOD RACHCFG LST RACHCFG

RACHCfg

MessageSizeGroup Message size of A select group A

eNodeB

MOD RACHCFG LST RACHCFG

RACHCfg

PrachFreqOffset

PRACH Frequency eNodeB Offset

MOD RACHCFG LST RACHCFG

RACHCfg

Indication of PrachConfigIndexCf PRACH eNodeB gInd Configuration Index

MOD RACHCFG LST RACHCFG

RACHCfg

PrachConfigIndex

PRACH eNodeB Configuration Index

MOD RACHCFG LST RACHCFG

SRSCfg

LocalCellId

Local cell ID

eNodeB

DSP SRSCFG LST SRSCFG MOD SRSCFG

SRSCfg

SrsSubframeCfg

SRS subframe configuration

eNodeB

MOD SRSCFG LST SRSCFG

SRSCfg

AnSrsSimuTrans

SRS ACK/NACK simultaneous transmission

eNodeB

MOD SRSCFG LST SRSCFG

SRSCfg

SrsCfgInd

SRS Configuration Indicator

eNodeB

MOD SRSCFG LST SRSCFG

SRSCfg

TddSrsCfgMode

TDD SRS eNodeB Configuration Mode

MOD SRSCFG LST SRSCFG

SRSCfg

CellSrsBandwidthCf Cell srs bandwidth g configuration

eNodeB

DSP SRSCFG

PHICHCfg

LocalCellId

Local cell ID

eNodeB

LST PHICHCFG MOD PHICHCFG

PHICHCfg

PhichDuration

PHICH duration

eNodeB

MOD PHICHCFG LST PHICHCFG

PHICHCfg

PhichResource

PHICH resource

eNodeB

MOD PHICHCFG LST PHICHCFG

PCCHCfg

LocalCellId

Local cell ID

eNodeB

LST PCCHCFG MOD PCCHCFG

PCCHCfg

DefaultPagingCycle Default paging cycle eNodeB

MOD PCCHCFG LST PCCHCFG

PCCHCfg

Nb

NB

eNodeB

MOD PCCHCFG LST PCCHCFG

PUSCHCfg

LocalCellId

Local cell ID

eNodeB

LST PUSCHCFG MOD PUSCHCFG

PUSCHCfg

Nsb

Subband number

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

HoppingMode

Hopping mode

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

HoppingOffset

Hopping offset

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

GroupHoppingEnab Group hopping led enabled

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

GroupAssignPUSC Group assignment H PUSCH

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

SeqHoppingEnable Sequence hopping d enabled

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

CyclicShift

Cyclic shift

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUSCHCfg

Qam64Enabled

Qam64 enabled

eNodeB

MOD PUSCHCFG LST PUSCHCFG

PUCCHCfg

LocalCellId

Local cell ID

eNodeB

LST PUCCHCFG MOD PUCCHCFG

PUCCHCfg

DeltaShift

Delta shift

eNodeB

MOD PUCCHCFG LST PUCCHCFG

PUCCHCfg

NaSriChNum

ACK/SRI Channel Number

eNodeB

MOD PUCCHCFG LST PUCCHCFG

PUCCHCfg

CqiRbNum

CQI RB number

eNodeB

MOD PUCCHCFG LST PUCCHCFG

Cdma2000ExternalCellPlmn CellGlobalId

Cell global ID

eNodeB

ADD CDMA2000EXTER NALCELLPLMN LST CDMA2000EXTER NALCELLPLMN RMV CDMA2000EXTER NALCELLPLMN

Cdma2000ExternalCellPlmn ShareMcc

Share mobile country code

eNodeB

ADD CDMA2000EXTER NALCELLPLMN LST CDMA2000EXTER NALCELLPLMN RMV CDMA2000EXTER NALCELLPLMN

Cdma2000ExternalCellPlmn ShareMnc

Share mobile network code

eNodeB

ADD CDMA2000EXTER NALCELLPLMN LST CDMA2000EXTER NALCELLPLMN RMV CDMA2000EXTER NALCELLPLMN

Cdma2000HrpdNcell LocalCellId

Local cell ID

eNodeB

ADD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL RMV CDMA2000HRPDN CELL

Cdma2000HrpdNcell CellGlobalId

Cell global ID

eNodeB

ADD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL RMV CDMA2000HRPDN CELL

Cdma2000HrpdNcell NoHoFlag

No handover indicator

eNodeB

ADD CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL ADD CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL

Cdma2000HrpdNcell NoRmvFlag

No remove indicator eNodeB

Cdma2000HrpdNcell BlindHoPriority

Blind handover priority

eNodeB

ADD CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL

Cdma2000HrpdNcell AnrFlag

ANR flag

eNodeB

LST CDMA2000HRPDN CELL

Cdma2000HrpdNcell LocalCellName

Local cell name

eNodeB

ADD CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL

Cdma2000HrpdNcell NeighbourCellName

Neighbour cell name

eNodeB

ADD CDMA2000HRPDN CELL MOD CDMA2000HRPDN CELL LST CDMA2000HRPDN CELL

Cdma2000Nfreq

LocalCellId

Local cell ID

eNodeB

ADD CDMA2000NFREQ LST CDMA2000NFREQ MOD CDMA2000NFREQ RMV CDMA2000NFREQ

Cdma2000Nfreq

BandClass

Band class

eNodeB

ADD CDMA2000NFREQ LST CDMA2000NFREQ MOD CDMA2000NFREQ RMV CDMA2000NFREQ

Cdma2000Nfreq

Frequency

Frequency

eNodeB

ADD CDMA2000NFREQ LST CDMA2000NFREQ MOD CDMA2000NFREQ RMV CDMA2000NFREQ

Cdma2000Nfreq

OffsetFreq

Frequency offset

eNodeB

ADD CDMA2000NFREQ MOD CDMA2000NFREQ LST CDMA2000NFREQ

Cdma2000Nfreq

SearchWindowSize Search window size eNodeB CfgInd configure indicator

ADD CDMA2000NFREQ MOD CDMA2000NFREQ LST CDMA2000NFREQ

Cdma2000Nfreq

SearchWindowSize Search window size eNodeB

ADD CDMA2000NFREQ MOD CDMA2000NFREQ LST CDMA2000NFREQ

EutranExternalCellPlmn Mcc

Mobile country code eNodeB

ADD EUTRANEXTERNA LCELLPLMN LST EUTRANEXTERNA LCELLPLMN RMV EUTRANEXTERNA LCELLPLMN

EutranExternalCellPlmn Mnc

Mobile network code

eNodeB

ADD EUTRANEXTERNA LCELLPLMN LST EUTRANEXTERNA LCELLPLMN RMV EUTRANEXTERNA LCELLPLMN

EutranExternalCellPlmn eNodeBId

eNodeB ID

eNodeB

ADD EUTRANEXTERNA LCELLPLMN LST EUTRANEXTERNA LCELLPLMN RMV EUTRANEXTERNA LCELLPLMN

EutranExternalCellPlmn CellId

Cell ID

eNodeB

ADD EUTRANEXTERNA LCELLPLMN LST EUTRANEXTERNA LCELLPLMN RMV EUTRANEXTERNA LCELLPLMN

EutranExternalCellPlmn ShareMcc

Share mobile country code

eNodeB

ADD EUTRANEXTERNA LCELLPLMN LST EUTRANEXTERNA LCELLPLMN RMV EUTRANEXTERNA LCELLPLMN

EutranExternalCellPlmn ShareMnc

Share mobile network code

eNodeB

ADD EUTRANEXTERNA LCELLPLMN LST EUTRANEXTERNA LCELLPLMN RMV EUTRANEXTERNA LCELLPLMN

GeranExternalCellPlmn GeranCellId

GERAN cell ID

eNodeB

ADD GERANEXTERNAL CELLPLMN LST GERANEXTERNAL CELLPLMN RMV GERANEXTERNAL CELLPLMN

GeranExternalCellPlmn Lac

Location area code eNodeB

ADD GERANEXTERNAL CELLPLMN LST GERANEXTERNAL CELLPLMN RMV GERANEXTERNAL CELLPLMN

GeranExternalCellPlmn Mcc

Mobile country code eNodeB

ADD GERANEXTERNAL CELLPLMN LST GERANEXTERNAL CELLPLMN RMV GERANEXTERNAL CELLPLMN

GeranExternalCellPlmn Mnc

Mobile network code

eNodeB

ADD GERANEXTERNAL CELLPLMN LST GERANEXTERNAL CELLPLMN RMV GERANEXTERNAL CELLPLMN

GeranExternalCellPlmn ShareMcc

Share mobile country code

eNodeB

ADD GERANEXTERNAL CELLPLMN LST GERANEXTERNAL CELLPLMN RMV GERANEXTERNAL CELLPLMN

GeranExternalCellPlmn ShareMnc

Share mobile network code

eNodeB

ADD GERANEXTERNAL CELLPLMN LST GERANEXTERNAL CELLPLMN RMV GERANEXTERNAL CELLPLMN

UtranExternalCellPlmn UtranCellId

UTRAN cell ID

eNodeB

ADD UTRANEXTERNAL CELLPLMN LST UTRANEXTERNAL CELLPLMN RMV UTRANEXTERNAL CELLPLMN

UtranExternalCellPlmn Mcc

Mobile country code eNodeB

ADD UTRANEXTERNAL CELLPLMN LST UTRANEXTERNAL CELLPLMN RMV UTRANEXTERNAL CELLPLMN

UtranExternalCellPlmn Mnc

Mobile network code

eNodeB

ADD UTRANEXTERNAL CELLPLMN LST UTRANEXTERNAL CELLPLMN RMV UTRANEXTERNAL CELLPLMN

UtranExternalCellPlmn ShareMcc

Share mobile country code

eNodeB

ADD UTRANEXTERNAL CELLPLMN LST UTRANEXTERNAL CELLPLMN RMV UTRANEXTERNAL CELLPLMN

UtranExternalCellPlmn ShareMnc

Share mobile network code

eNodeB

ADD UTRANEXTERNAL CELLPLMN LST UTRANEXTERNAL CELLPLMN RMV UTRANEXTERNAL CELLPLMN

Cdma2000ExternalCell CellGlobalId

Cell global ID

eNodeB

ADD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL RMV CDMA2000EXTER NALCELL

Cdma2000ExternalCell BandClass

Band class

eNodeB

ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL

Cdma2000ExternalCell Frequency

Frequency

eNodeB

Cdma2000ExternalCell PnOffset

Physical cell ID

eNodeB

ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL

Cdma2000ExternalCell Cdma2000Type

CDMA2000 neighbor cell type

eNodeB

ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL

Cdma2000ExternalCell Mcc

Mobile country code eNodeB

ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL

Cdma2000ExternalCell Mnc

Mobile network code

eNodeB

ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL

Cdma2000ExternalCell CellName

Cell name

eNodeB

ADD CDMA2000EXTER NALCELL MOD CDMA2000EXTER NALCELL LST CDMA2000EXTER NALCELL

Cdma20001XRTTNcell LocalCellId

Local cell ID

eNodeB

ADD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL RMV CDMA20001XRTT NCELL

Cdma20001XRTTNcell CellGlobalId

Cell global ID

eNodeB

ADD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL RMV CDMA20001XRTT NCELL

Cdma20001XRTTNcell NoHoFlag

No handover indicator

eNodeB

ADD CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL ADD CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL

Cdma20001XRTTNcell NoRmvFlag

No remove indicator eNodeB

Cdma20001XRTTNcell BlindHoPriority

Blind handover priority

eNodeB

ADD CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL

Cdma20001XRTTNcell AnrFlag

ANR flag

eNodeB

LST CDMA20001XRTT NCELL

Cdma20001XRTTNcell LocalCellName

Local cell name

eNodeB

ADD CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL

Cdma20001XRTTNcell NeighbourCellName

Neighbour cell name

eNodeB

ADD CDMA20001XRTT NCELL MOD CDMA20001XRTT NCELL LST CDMA20001XRTT NCELL

Cdma2000BandClass LocalCellId

Local cell ID

eNodeB

ADD CDMA2000BANDC LASS LST CDMA2000BANDC LASS MOD CDMA2000BANDC LASS RMV CDMA2000BANDC LASS ADD CDMA2000BANDC LASS LST CDMA2000BANDC LASS MOD CDMA2000BANDC LASS RMV CDMA2000BANDC LASS

Cdma2000BandClass BandClass

Band class

eNodeB

Cdma2000BandClass CellReselPriority

Cell reselection priority

eNodeB

ADD CDMA2000BANDC LASS MOD CDMA2000BANDC LASS LST CDMA2000BANDC LASS

Cdma2000BandClass ThreshXHigh

High priority threshold

eNodeB

ADD CDMA2000BANDC LASS MOD CDMA2000BANDC LASS LST CDMA2000BANDC LASS

Cdma2000BandClass ThreshXLow

Lower priority threshold

eNodeB

ADD CDMA2000BANDC LASS MOD CDMA2000BANDC LASS LST CDMA2000BANDC LASS

GeranExternalCell

Mcc

Mobile country code eNodeB

ADD GERANEXTERNAL CELL LST GERANEXTERNAL CELL MOD GERANEXTERNAL CELL RMV GERANEXTERNAL CELL

GeranExternalCell

Mnc

Mobile network code

eNodeB

ADD GERANEXTERNAL CELL LST GERANEXTERNAL CELL MOD GERANEXTERNAL CELL RMV GERANEXTERNAL CELL ADD GERANEXTERNAL CELL LST GERANEXTERNAL CELL MOD GERANEXTERNAL CELL RMV GERANEXTERNAL CELL ADD GERANEXTERNAL CELL LST GERANEXTERNAL CELL MOD GERANEXTERNAL CELL RMV GERANEXTERNAL CELL ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

GeranCellId

GERAN cell ID

eNodeB

GeranExternalCell

Lac

Location area code eNodeB

GeranExternalCell

RacCfgInd

Routing area code configure indicator

eNodeB

GeranExternalCell

Rac

Routing area code

eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

BandIndicator

Band indicator

eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

GeranArfcn

GERAN ARFCN

eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

NetworkColourCode Network color code eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

BaseStationColour Code

Base station color code

eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

DtmInd

DTM indication

eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

CellName

Cell name

eNodeB

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranExternalCell

CsPsHOInd

CS and PS eNodeB handover indication

ADD GERANEXTERNAL CELL MOD GERANEXTERNAL CELL LST GERANEXTERNAL CELL

GeranNcell

LocalCellId

Local cell ID

eNodeB

ADD GERANNCELL DSP GERANRIMINFO LST GERANNCELL MOD GERANNCELL RMV GERANNCELL

GeranNcell

Mcc

Mobile country code eNodeB

ADD GERANNCELL LST GERANNCELL MOD GERANNCELL RMV GERANNCELL DSP GERANRIMINFO

GeranNcell

Mnc

Mobile network code

eNodeB

ADD GERANNCELL LST GERANNCELL MOD GERANNCELL RMV GERANNCELL DSP GERANRIMINFO

GeranNcell

Lac

Location area code eNodeB

ADD GERANNCELL LST GERANNCELL MOD GERANNCELL RMV GERANNCELL DSP GERANRIMINFO ADD GERANNCELL LST GERANNCELL MOD GERANNCELL RMV GERANNCELL DSP GERANRIMINFO

GeranNcell

GeranCellId

GERAN cell ID

eNodeB

GeranNcell

NoRmvFlag

No remove indicator eNodeB

ADD GERANNCELL MOD GERANNCELL LST GERANNCELL ADD GERANNCELL MOD GERANNCELL LST GERANNCELL

GeranNcell

NoHoFlag

No handover indicator

eNodeB

GeranNcell

BlindHoPriority

Blind handover priority

eNodeB

ADD GERANNCELL MOD GERANNCELL LST GERANNCELL

GeranNcell

AnrFlag

ANR flag

eNodeB

LST GERANNCELL

GeranNcell

LocalCellName

Local cell name

eNodeB

ADD GERANNCELL MOD GERANNCELL LST GERANNCELL

GeranNcell

NeighbourCellName

Neighbour cell name

eNodeB

ADD GERANNCELL MOD GERANNCELL LST GERANNCELL

GeranNcell

eNodeBId

eNodeB ID

eNodeB

DSP GERANRIMINFO

GeranNcell

GRimBeginningTim Rim latest start time eNodeB e

DSP GERANRIMINFO

GeranNcell

GLastRimUpdating Rim latest update Time time

eNodeB

DSP GERANRIMINFO

GeranNfreqGroup

LocalCellId

Local cell ID

eNodeB

ADD GERANNFREQGR OUP LST GERANNFREQGR OUP MOD GERANNFREQGR OUP RMV GERANNFREQGR OUP ADD GERANNFREQGR OUP LST GERANNFREQGR OUP MOD GERANNFREQGR OUP RMV GERANNFREQGR OUP ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

BcchGroupId

BCCH group ID

eNodeB

GeranNfreqGroup

GeranVersion

GERAN version

eNodeB

GeranNfreqGroup

StartingArfcn

Starting ARFCN

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

BandIndicator

Band indicator

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

Cell reselection CellReselPriorityCfg priority configure Ind indicator

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

CellReselPriority

Cell reselection priority

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

PmaxGeranCfgInd

PMAX configure indicator

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

PmaxGeran

PMAX

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

QRxLevMin

Minimum required RX level

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

ThreshXHigh

High priority threshold

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

ThreshXLow

Lower priority threshold

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

OffsetFreq

Frequency offset

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP

GeranNfreqGroup

NccPermitted

NCC monitoring permitted

eNodeB

ADD GERANNFREQGR OUP MOD GERANNFREQGR OUP LST GERANNFREQGR OUP ADD GERANNFREQGR OUPARFCN LST GERANNFREQGR OUPARFCN RMV GERANNFREQGR OUPARFCN

GeranNfreqGroupArfcn LocalCellId

Local cell ID

eNodeB

GeranNfreqGroupArfcn BcchGroupId

BCCH group ID

eNodeB

ADD GERANNFREQGR OUPARFCN LST GERANNFREQGR OUPARFCN RMV GERANNFREQGR OUPARFCN ADD GERANNFREQGR OUPARFCN LST GERANNFREQGR OUPARFCN RMV GERANNFREQGR OUPARFCN ADD INTRAFREQBLKC ELL LST INTRAFREQBLKC ELL MOD INTRAFREQBLKC ELL RMV INTRAFREQBLKC ELL ADD INTRAFREQBLKC ELL LST INTRAFREQBLKC ELL MOD INTRAFREQBLKC ELL RMV INTRAFREQBLKC ELL ADD INTRAFREQBLKC ELL MOD INTRAFREQBLKC ELL LST INTRAFREQBLKC ELL

GeranNfreqGroupArfcn GeranArfcn

GERAN ARFCN

eNodeB

IntraFreqBlkCell

LocalCellId

Local cell ID

eNodeB

IntraFreqBlkCell

PhyCellId

Start physical cell ID

eNodeB

IntraFreqBlkCell

CellName

Cell name

eNodeB

IntraFreqBlkCell

PhyCellIdRange

Physical cell ID range

eNodeB

ADD INTRAFREQBLKC ELL MOD INTRAFREQBLKC ELL LST INTRAFREQBLKC ELL ADD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL RMV EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellLocalCellId

Local cell ID

eNodeB

EutranIntraFreqNCellMcc

Mobile country code eNodeB

ADD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL RMV EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellMnc

Mobile network code

eNodeB

ADD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL RMV EUTRANINTRAFR EQNCELL

EutranIntraFreqNCelleNodeBId

eNodeB ID

eNodeB

ADD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL RMV EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellCellId

Cell ID

eNodeB

ADD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL RMV EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellCellIndividualOffset Cell individual offset eNodeB

ADD EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellCellQoffset

Cell offset

eNodeB

ADD EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellNoHoFlag

No handover indicator

eNodeB

ADD EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL ADD EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellNoRmvFlag

No remove indicator eNodeB

EutranIntraFreqNCellAnrFlag

ANR flag

eNodeB

EutranIntraFreqNCellLocalCellName

Local cell name

eNodeB

ADD EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL

EutranIntraFreqNCellNeighbourCellName

Neighbour cell name

eNodeB

ADD EUTRANINTRAFR EQNCELL MOD EUTRANINTRAFR EQNCELL LST EUTRANINTRAFR EQNCELL

EutranInterNFreq

LocalCellId

Local cell ID

eNodeB

ADD EUTRANINTERNF REQ LST EUTRANINTERNF REQ MOD EUTRANINTERNF REQ RMV EUTRANINTERNF REQ

EutranInterNFreq

DlEarfcn

Downlink EARFCN eNodeB

ADD EUTRANINTERNF REQ LST EUTRANINTERNF REQ MOD EUTRANINTERNF REQ RMV EUTRANINTERNF REQ

EutranInterNFreq

UlEarfcnCfgInd

Uplink EARFCN configure indicator

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

UlEarfcn

Uplink EARFCN

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

Inter frequency cell CellReselPriorityCfg resel priority eNodeB Ind configure indicator

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

CellReselPriority

Inter frequency cell eNodeB resel priority

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

EutranReselTime

EUTRAN reselection time

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

Speed dependent SpeedDependSPCf resel parameter eNodeB gInd configuring indicator

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

Scaling factor of TReselEutranSfMe treseleutra in dium medium mobility state

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

Scaling factor of TReselEutranSfHig treseleutra in high h mobility state

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

MeasBandWidth

Measurement bandwidth

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

QoffsetFreq

Frequency offset

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

ThreshXhigh

Inter frequency high eNodeB priority threshold

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

ThreshXlow

Inter frequency lower priority threshold

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

QRxLevMin

Minimum required RX level

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

PmaxCfgInd

PMAX configure indicator

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

Pmax

PMAX

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

NeighCellConfig

Neighbor cell config eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

PresenceAntennaP Presence antenna ort1 port1

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

InterFreqHoEventTy Inter-Freq HO pe trigger Event Type

eNodeB

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

ThreshXhighQ

Inter frequency high priority RSRQ eNodeB threshold

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

ThreshXlowQ

Inter frequency low priority RSRQ eNodeB threshold

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

QqualMinCfgInd

Minimum RX signal quality configuration eNodeB indicator

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

EutranInterNFreq

QqualMin

Minimum RX signal eNodeB quality

ADD EUTRANINTERNF REQ MOD EUTRANINTERNF REQ LST EUTRANINTERNF REQ

InterFreqBlkCell

LocalCellId

Local cell ID

eNodeB

ADD INTERFREQBLKC ELL LST INTERFREQBLKC ELL MOD INTERFREQBLKC ELL RMV INTERFREQBLKC ELL

InterFreqBlkCell

DlEarfcn

Downlink EARFCN eNodeB

ADD INTERFREQBLKC ELL LST INTERFREQBLKC ELL MOD INTERFREQBLKC ELL RMV INTERFREQBLKC ELL

InterFreqBlkCell

PhyCellId

Start physical cell ID

eNodeB

ADD INTERFREQBLKC ELL LST INTERFREQBLKC ELL MOD INTERFREQBLKC ELL RMV INTERFREQBLKC ELL ADD INTERFREQBLKC ELL MOD INTERFREQBLKC ELL LST INTERFREQBLKC ELL

InterFreqBlkCell

CellName

Cell name

eNodeB

InterFreqBlkCell

PhyCellIdRange

Physical cell ID range

eNodeB

ADD INTERFREQBLKC ELL MOD INTERFREQBLKC ELL LST INTERFREQBLKC ELL ADD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL RMV EUTRANINTERFR EQNCELL

EutranInterFreqNCellLocalCellId

Local cell ID

eNodeB

EutranInterFreqNCellMcc

Mobile country code eNodeB

ADD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL RMV EUTRANINTERFR EQNCELL

EutranInterFreqNCellMnc

Mobile network code

eNodeB

ADD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL RMV EUTRANINTERFR EQNCELL

EutranInterFreqNCelleNodeBId

eNodeB ID

eNodeB

ADD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL RMV EUTRANINTERFR EQNCELL

EutranInterFreqNCellCellId

Cell ID

eNodeB

ADD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL RMV EUTRANINTERFR EQNCELL

EutranInterFreqNCellCellIndividualOffset Cell individual offset eNodeB

ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL

EutranInterFreqNCellCellQoffset

Cell offset

eNodeB

ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL

EutranInterFreqNCellNoHoFlag

No handover indicator

eNodeB

ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL

EutranInterFreqNCellNoRmvFlag

No remove indicator eNodeB

EutranInterFreqNCellBlindHoPriority

Blind handover Priority

eNodeB

ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL

EutranInterFreqNCellAnrFlag

ANR flag

eNodeB

LST EUTRANINTERFR EQNCELL

EutranInterFreqNCellLocalCellName

Local cell name

eNodeB

ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL

EutranInterFreqNCellNeighbourCellName

Neighbour cell name

eNodeB

ADD EUTRANINTERFR EQNCELL MOD EUTRANINTERFR EQNCELL LST EUTRANINTERFR EQNCELL

EutranExternalCell

Mcc

Mobile country code eNodeB

ADD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL RMV EUTRANEXTERNA LCELL

EutranExternalCell

Mnc

Mobile network code

eNodeB

ADD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL RMV EUTRANEXTERNA LCELL

EutranExternalCell

eNodeBId

eNodeB ID

eNodeB

ADD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL RMV EUTRANEXTERNA LCELL

EutranExternalCell

CellId

Cell ID

eNodeB

ADD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL RMV EUTRANEXTERNA LCELL

EutranExternalCell

DlEarfcn

Downlink EARFCN eNodeB

ADD EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL

EutranExternalCell

UlEarfcnCfgInd

Uplink EARFCN indicator

eNodeB

ADD EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL

EutranExternalCell

UlEarfcn

Uplink EARFCN

eNodeB

ADD EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL

EutranExternalCell

PhyCellId

Physical cell ID

eNodeB

ADD EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL

EutranExternalCell

Tac

Tracking area code eNodeB

ADD EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL

EutranExternalCell

CellName

Cell name

eNodeB

ADD EUTRANEXTERNA LCELL MOD EUTRANEXTERNA LCELL LST EUTRANEXTERNA LCELL

GeranRanShare

LocalCellId

Local cell ID

eNodeB

ADD GERANRANSHAR E LST GERANRANSHAR E MOD GERANRANSHAR E RMV GERANRANSHAR E ADD GERANRANSHAR E LST GERANRANSHAR E MOD GERANRANSHAR E RMV GERANRANSHAR E

GeranRanShare

BcchGroupId

BCCH group ID

eNodeB

GeranRanShare

Mcc

Mobile country code eNodeB

ADD GERANRANSHAR E LST GERANRANSHAR E MOD GERANRANSHAR E RMV GERANRANSHAR E

GeranRanShare

Mnc

Mobile network code

eNodeB

ADD GERANRANSHAR E LST GERANRANSHAR E MOD GERANRANSHAR E RMV GERANRANSHAR E

GeranRanShare

Cell reselection CellReselPriorityCfg priority configure Ind indicator

eNodeB

ADD GERANRANSHAR E MOD GERANRANSHAR E LST GERANRANSHAR E

GeranRanShare

CellReselPriority

Cell reselection priority

eNodeB

ADD GERANRANSHAR E MOD GERANRANSHAR E LST GERANRANSHAR E

UtranNCell

LocalCellId

Local cell ID

eNodeB

ADD UTRANNCELL DSP UTRANRIMINFO LST UTRANNCELL MOD UTRANNCELL RMV

UtranNCell

Mcc

Mobile country code eNodeB

ADD UTRANNCELL LST UTRANNCELL MOD UTRANNCELL RMV UTRANNCELL DSP UTRANRIMINFO

UtranNCell

Mnc

Mobile network code

eNodeB

ADD UTRANNCELL LST UTRANNCELL MOD UTRANNCELL RMV UTRANNCELL DSP UTRANRIMINFO

UtranNCell

UtranCellId

UTRAN cell ID

eNodeB

ADD UTRANNCELL LST UTRANNCELL MOD UTRANNCELL RMV UTRANNCELL DSP UTRANRIMINFO

UtranNCell

NoHoFlag

No handover indicator

eNodeB

ADD UTRANNCELL MOD UTRANNCELL LST UTRANNCELL

UtranNCell

NoRmvFlag

No remove indicator eNodeB

ADD UTRANNCELL MOD UTRANNCELL LST UTRANNCELL

UtranNCell

BlindHoPriority

Blind handover priority

eNodeB

ADD UTRANNCELL MOD UTRANNCELL LST UTRANNCELL

UtranNCell

AnrFlag

ANR flag

eNodeB

LST UTRANNCELL

UtranNCell

LocalCellName

Local cell name

eNodeB

ADD UTRANNCELL MOD UTRANNCELL LST UTRANNCELL

UtranNCell

NeighbourCellName

Neighbour cell name

eNodeB

ADD UTRANNCELL MOD UTRANNCELL LST UTRANNCELL

UtranNCell

eNodeBId

eNodeB ID

eNodeB

DSP UTRANRIMINFO

UtranNCell

RncId

RNC ID

eNodeB

DSP UTRANRIMINFO

UtranNCell

URimBeginningTim Rim latest start time eNodeB e

DSP UTRANRIMINFO

UtranNCell

ULastRimUpdatingT RIM latest update ime time

eNodeB

DSP UTRANRIMINFO ADD UTRANRANSHAR E LST UTRANRANSHAR E MOD UTRANRANSHAR E

UtranRanShare

LocalCellId

Local cell ID

eNodeB

UtranRanShare

UtranDlArfcn

Downlink UARFCN eNodeB

ADD UTRANRANSHAR E LST UTRANRANSHAR E MOD UTRANRANSHAR E RMV UTRANRANSHAR E

UtranRanShare

Mcc

Mobile country code eNodeB

ADD UTRANRANSHAR E LST UTRANRANSHAR E MOD UTRANRANSHAR E RMV UTRANRANSHAR E

UtranRanShare

Mnc

Mobile network code

eNodeB

ADD UTRANRANSHAR E LST UTRANRANSHAR E MOD UTRANRANSHAR E RMV UTRANRANSHAR E

UtranRanShare

Cell reselection CellReselPriorityCfg priority configure Ind indicator

eNodeB

ADD UTRANRANSHAR E MOD UTRANRANSHAR E LST UTRANRANSHAR

UtranRanShare

CellReselPriority

Cell reselection priority

eNodeB

ADD UTRANRANSHAR E MOD UTRANRANSHAR E LST UTRANRANSHAR E

UtranNFreq

LocalCellId

Local cell ID

eNodeB

ADD UTRANNFREQ LST UTRANNFREQ MOD UTRANNFREQ RMV UTRANNFREQ

UtranNFreq

UtranDlArfcn

Downlink UARFCN eNodeB

ADD UTRANNFREQ LST UTRANNFREQ MOD UTRANNFREQ RMV UTRANNFREQ

UtranNFreq

UtranVersion

UTRAN version

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

UtranFddTddType

UTRAN cell type indicator

eNodeB

UtranNFreq

UtranUlArfcnCfgInd

Uplink UARFCN indicator

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

UtranUlArfcn

Uplink UARFCN

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

CellReselPriorityCfg Reselection priority eNodeB Ind configure indicator

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

CellReselPriority

Cell reselection priority

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

PmaxUtran

PMAX

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

OffsetFreq

Frequency offset

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

Qqualmin

Minimum required quality level

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

QRxLevMin

Minimum required RX level

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

ThreshXHigh

UTRAN high priority eNodeB threshold

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

ThreshXLow

UTRAN lower priority threshold

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

ThreshXHighQ

UTRAN high priority eNodeB RSRQ threshold

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

ThreshXLowQ

UTRAN low priority eNodeB RSRQ threshold

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

PsPriority

PS service priority

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranNFreq

CsPriority

CS service priority

eNodeB

ADD UTRANNFREQ MOD UTRANNFREQ LST UTRANNFREQ

UtranExternalCell

Mcc

Mobile country code eNodeB

ADD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL RMV UTRANEXTERNAL CELL

UtranExternalCell

Mnc

Mobile network code

eNodeB

ADD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL RMV UTRANEXTERNAL CELL

UtranExternalCell

UtranCellId

UTRAN cell ID

eNodeB

ADD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL RMV UTRANEXTERNAL CELL

UtranExternalCell

UtranFddTddType

UTRAN cell type indicator

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

UtranDlArfcn

Downlink UARFCN eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

UtranUlArfcnCfgInd

Uplink UARFCN configure indicator

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

UtranUlArfcn

Uplink UARFCN

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

RncId

RNC ID

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

RacCfgInd

Routing area code configure indicator

eNodeB

UtranExternalCell

Rac

Routing area code

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

PScrambCode

Primary scrambling eNodeB code

UtranExternalCell

Lac

Location area code eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

CellName

Cell name

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

UtranExternalCell

CsPsHOInd

CS and PS handover indicator

eNodeB

ADD UTRANEXTERNAL CELL MOD UTRANEXTERNAL CELL LST UTRANEXTERNAL CELL

ANR

AddCellThd

ANR add cell threshold

eNodeB

MOD ANR LST ANR

ANR

DelCellThd

ANR delete cell threshold

eNodeB

MOD ANR LST ANR

ANR

NcellHoStatNum

Least Handover Num for Statistic

eNodeB

MOD ANR LST ANR

ANR

StatisticPeriod

Statistic cycle

eNodeB

MOD ANR LST ANR

ANR

FastAnrRprtAmount

Fast ANR PCI report amount

eNodeB

MOD ANR LST ANR

ANR

FastAnrRprtInterval

Fast ANR PCI report interval

eNodeB

MOD ANR LST ANR

ANR

FastAnrCheckPerio Fast ANR checking eNodeB d period

MOD ANR LST ANR

ANR

FastAnrRsrpThd

Fast ANR measurement RSRP threshold

eNodeB

MOD ANR LST ANR

ANR

IntraRat Fast ANR FastAnrIntraRatMea measurement UE sUeNum number

eNodeB

MOD ANR LST ANR

ANR

InterRat Fast ANR FastAnrInterRatMea measurement UE sUeNum number

eNodeB

MOD ANR LST ANR

ANR

FastAnrIntraRatUe NumThd

IntraRat Fast ANR valid measurement eNodeB min UE number

MOD ANR LST ANR

ANR

FastAnrInterRatUe NumThd

InterRat Fast ANR valid measurement eNodeB min UE number

MOD ANR LST ANR

ANR

OptMode

Optimization Mode

eNodeB

MOD ANR LST ANR

ANR

StatisticPeriodForN Statistic Cycle For RTDel Delete NRT

eNodeB

MOD ANR LST ANR

ANR

StatisticNumForNR Statistic Number TDel For Delete NRT

eNodeB

MOD ANR LST ANR

ANR

ANR Active PCI ActivePciConflictSw Conflict Detection itch Switch

eNodeB

MOD ANR LST ANR

ANR

StartTime

Start time

eNodeB

MOD ANR LST ANR

ANR

StopTime

Stop time

eNodeB

MOD ANR LST ANR

ANR

FastAnrRscpThd

UTRAN Fast ANR RSCP threshold

eNodeB

MOD ANR LST ANR

ANR

FastAnrRssiThd

GERAN Fast ANR RSSI threshold

eNodeB

MOD ANR LST ANR

ANR

CDMA2000 1XRTT FastAnrCdma1xrttPi Fast ANR Pilot eNodeB lotThd threshold

MOD ANR LST ANR

ANR

CDMA2000 HRPD FastAnrCdmahrpdP Fast ANR Pilot ilotThd threshold

eNodeB

MOD ANR LST ANR

CellIdPrdUpt

PrdUptSwitch

Period update switch

eNodeB

MOD CELLIDPRDUPT LST CELLIDPRDUPT

CellIdPrdUpt

ActionTime

Action time

eNodeB

MOD CELLIDPRDUPT LST CELLIDPRDUPT

CellIdPrdUpt

Period

Period

eNodeB

MOD CELLIDPRDUPT LST CELLIDPRDUPT

ENodeBAlgoSwitch HoAlgoSwitch

Handover Algo switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch HoModeSwitch

Handover Mode switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch DlIcicSwitch

DlIcic algorithm switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch AnrSwitch

ANR algorithm switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch RedirectSwitch

Redirection switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch MroSwitch

MRO algorithm switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch TpeSwitch

TPE switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch UlIcicTimeSwitch

UlIcic time switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch UlIcicFreqSwitch

UlIcic freq switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch LcsSwitch

LCS switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch TrmSwitch

TRM switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch

PciConflictAlmSwitc PCI conflict alarm h switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch PowerSaveSwitch

Power save switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch RimSwitch

RIM switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch

ANR Under RAN RanSharingAnrSwit Sharing Algorithm ch Switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

ENodeBAlgoSwitch FreqLayerSwtich

Frequency Layer Switch

eNodeB

MOD ENODEBALGOSWI TCH LST ENODEBALGOSWI TCH

LICENSEALMTHD OPRD

OPRD

eNodeB

SET LICENSEALMTHD LST LICENSEALMTHD

LICENSEALMTHD OTHD

OTHD

eNodeB

SET LICENSEALMTHD LST LICENSEALMTHD

LICENSEALMTHD RPRD

RPRD

eNodeB

SET LICENSEALMTHD LST LICENSEALMTHD

LICENSEALMTHD RTHD

RTHD

eNodeB

SET LICENSEALMTHD LST LICENSEALMTHD

LicRatio

UpLicRatio

Uplink Traffic License Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

TrafficSharingType

Traffic Sharing Type

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator1TrfRatio

Operator 1 Traffic Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator2TrfRatio

Operator 2 Traffic Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator3TrfRatio

Operator 3 Traffic Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator4TrfRatio

Operator 4 Traffic Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator1TrfSharin Operator 1 Traffic gRatio Sharing Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator2TrfSharin Operator 2 Traffic gRatio Sharing Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator3TrfSharin Operator 3 Traffic gRatio Sharing Ratio

eNodeB

MOD LICRATIO LST LICRATIO

LicRatio

Operator4TrfSharin Operator 4 Traffic gRatio Sharing Ratio

eNodeB

MOD LICRATIO LST LICRATIO

MRO

OptPeriod

MRO optimization period

eNodeB

MOD MRO LST MRO

MRO

NcellOptThd

Ncell optimization threshold

eNodeB

MOD MRO LST MRO

MRO

StatNumThd

MRO statistics number threshold

eNodeB

MOD MRO LST MRO

MRO

PingpongTimeThd

Pingpong handover eNodeB threshold

MOD MRO LST MRO

MRO

PingpongRatioThd

Pingpong ratio threshold

eNodeB

MOD MRO LST MRO

MRO

CoverAbnormalThd

Abnormal coverage eNodeB threshold

MOD MRO LST MRO

MRO

ServingRsrpThd

Serving cell RSRP threshold

eNodeB

MOD MRO LST MRO

MRO

NeighborRsrpThd

Neighbour cell RSRP threshold

eNodeB

MOD MRO LST MRO

SimuLoad

SimuLoadCfgIndex configuration index eNodeB

LST SIMULOAD MOD SIMULOAD

SimuLoad

SimuLoadRbThd

RB usage threshold eNodeB

MOD SIMULOAD LST SIMULOAD

SimuLoad

SimuLoadPwrThd

Power usage threshold

eNodeB

MOD SIMULOAD LST SIMULOAD

SimuLoad

SimuLoadReportPe Report period riod

eNodeB

MOD SIMULOAD LST SIMULOAD

SimuLoad

SimuLoadStatPerio Statistic period d

eNodeB

MOD SIMULOAD LST SIMULOAD

SimuLoad

FreqSelSwitch

Frequency selective eNodeB switch

MOD SIMULOAD LST SIMULOAD

TcpAckCtrlAlgo

AckCtrlSwitch

TCP ACK Control Switch

eNodeB

MOD TCPACKCTRLALG O LST TCPACKCTRLALG O

TcpAckCtrlAlgo

DlMaxThroughput

DL Max Throughput eNodeB

MOD TCPACKCTRLALG O LST TCPACKCTRLALG O

TcpAckCtrlAlgo

CtrlTimerLength

Control Timer Length

eNodeB

MOD TCPACKCTRLALG O LST TCPACKCTRLALG O

TddFrameOffset

TimeOffset

TDD time offset

eNodeB

MOD TDDFRAMEOFFSE T LST TDDFRAMEOFFSE T

TpeAlgo

PortListNum

TCP Port Number

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port1

TCP Port 1

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port2

TCP Port 2

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port3

TCP Port 3

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port4

TCP Port 4

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port5

TCP Port 5

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port6

TCP Port 6

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port7

TCP Port 7

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port8

TCP Port 8

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port9

TCP Port 9

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port10

TCP Port 10

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port11

TCP Port 11

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port12

TCP Port 12

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port13

TCP Port 13

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port14

TCP Port 14

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port15

TCP Port 15

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port16

TCP Port 16

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port17

TCP Port 17

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port18

TCP Port 18

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port19

TCP Port 19

eNodeB

MOD TPEALGO LST TPEALGO

TpeAlgo

Port20

TCP Port 20

eNodeB

MOD TPEALGO LST TPEALGO ADD NODETORSCGRP LST NODETORSCGRP MOD NODETORSCGRP RMV NODETORSCGRP ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP

NODETORSCGRP

OBJTORSCGROU Mapping ID PID

eNodeB

NODETORSCGRP S1X2FLAG

S1/X2 Identifier

eNodeB

NODETORSCGRP ISALLMATCH

IsAllMatch

eNodeB

ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP

NODETORSCGRP ENDPOINTID

Node Identifier

eNodeB

ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP

NODETORSCGRP CABINETNO

CabinetNo

eNodeB

ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP

NODETORSCGRP SUBRACKNO

SubrackNo

eNodeB

NODETORSCGRP SLOTNO

SlotNo

eNodeB

NODETORSCGRP RSCGRPT

Transmission Resource Group Bear Type

eNodeB

NODETORSCGRP RSCGRPN

Transmission eNodeB Resource Group ID

NODETORSCGRP SBT

Subboard Type

eNodeB

ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP

NODETORSCGRP PN

Bearing Port No.

eNodeB

ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP ADD NODETORSCGRP MOD NODETORSCGRP LST NODETORSCGRP ADD SONSECPARA LST SONSECPARA MOD SONSECPARA RMV SONSECPARA ADD SONSECPARA MOD SONSECPARA LST SONSECPARA ADD SONSECPARA MOD SONSECPARA LST SONSECPARA ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

NODETORSCGRP PT

Bearing Port Type

eNodeB

SonSecPara

SONSECPARANA ME

Son IPsec Parameter Name

eNodeB

SonSecPara

PROPID

IKE Proposal ID

eNodeB

SonSecPara

PROPNAME

IPsec Proposal Name

eNodeB

SonSecPara

APPTYPE

Application Type

eNodeB

SonSecPara

IKEVERSION

IKE Version

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

EXCHMODE

Exchange Mode

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

PKEY

Pre-shared Key

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

DPD

DPD Mode

eNodeB

SonSecPara

DPDIDLETIME

DPD Idle Time

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

DPDRETRI

DPD Retransmission Interval

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

DPDRETRN

DPD Retransmission Count

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

PFS

Perfect Forward Secrecy

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

LTCFG

SA Duration Mode

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

LTS

Lifetime Based On Time

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA

SonSecPara

LTKB

Lifetime Based On Traffic

eNodeB

ADD SONSECPARA MOD SONSECPARA LST SONSECPARA ADD SONSECPARA MOD SONSECPARA LST SONSECPARA ADD MME6 DSP MME6 LST MME6 MOD MME6 RMV MME6

SonSecPara

CNOPERATORID

CN Operator ID

eNodeB

MME6

MMEID

MME6 ID

eNodeB

MME6

SIGIP1

First Signaling IPv6 eNodeB Address

ADD MME6 MOD MME6 LST MME6

MME6

SIGIP1SECFLAG

First Signaling IP IPsec Flag

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

IKEPEERNM1

First IPv6 IKEPeer Name

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

IPSECPROPNM1

First IPsec Proposal eNodeB Name

ADD MME6 MOD MME6 LST MME6

MME6

SIGIP2

Second Signaling IPv6 Address

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

SIGIP2SECFLAG

Second Signaling IP eNodeB IPsec Flag

ADD MME6 MOD MME6 LST MME6

MME6

IKEPEERNM2

Second IPv6 IKEPeer Name

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

IPSECPROPNM2

Second IPsec Proposal Name

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

LOCPORT

App Port No.

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

DESCRIPTION

Description of IPv6 eNodeB MME

ADD MME6 MOD MME6 LST MME6

MME6

CNOPERATORID

CN Operator ID

eNodeB

ADD MME6 MOD MME6 LST MME6

MME6

MMERELEASE

MME Release

eNodeB

ADD MME6 MOD MME6 LST MME6

MME

MMEID

MME ID

eNodeB

ADD MME DSP MME LST MME MOD MME RMV MME

MME

FIRSTSIGIP

First Signalling IP

eNodeB

ADD MME MOD MME LST MME

MME

FIRSTIPSECFLAG First IPSec Flag

eNodeB

ADD MME MOD MME LST MME

MME

FIRSTIKEPEERNM First IKEPeer Name eNodeB

ADD MME MOD MME LST MME

MME

FIRSTIPSECPROP First IPsec Proposal eNodeB NM Name

ADD MME MOD MME LST MME

MME

SECSIGIP

Second Signalling IP

eNodeB

ADD MME MOD MME LST MME

MME

SECIPSECFLAG

Second IPSec Flag eNodeB

ADD MME MOD MME LST MME

MME

SECIKEPEERNM

Second IKEPeer Name

eNodeB

ADD MME MOD MME LST MME

MME

SECIPSECPROPN Second IPsec M Proposal Name

eNodeB

ADD MME MOD MME LST MME

MME

LOCPORT

App Port No.

eNodeB

ADD MME MOD MME LST MME

MME

DESCRIPTION

Description of MME eNodeB

ADD MME MOD MME LST MME

MME

CNOPERATORID

CN Operator ID

eNodeB

ADD MME MOD MME LST MME

MME

MMERELEASE

MME Release

eNodeB

ADD MME MOD MME LST MME

S1ServIP

CN

Cabinet No.

eNodeB

ADD S1SERVIP MOD S1SERVIP DSP X2ENODEB LST S1SERVIP

S1ServIP

SRN

Subrack No.

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP

SN

Slot No.

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP

S1SERVIPID

S1 Service IP ID

eNodeB

ADD S1SERVIP LST S1SERVIP MOD S1SERVIP RMV S1SERVIP

S1ServIP

S1SERVIP

S1 Service IP

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP

IPSECFLAG

IPSec Flag

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP

IKEIP

Local IKE IP

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP

PATHCHK

Path Check

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP

CNOPERATORID

CN Operator ID

eNodeB

ADD S1SERVIP MOD S1SERVIP LST S1SERVIP

S1ServIP6

S1ServIP6ID

S1ServIP6 ID

eNodeB

ADD S1SERVIP6 LST S1SERVIP6 MOD S1SERVIP6 RMV S1SERVIP6

S1ServIP6

CN

Cabinet No.

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

SRN

Subrack No.

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

SN

Slot No.

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

SERVIP

Local Service IPv6 Address

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

SERVIPSECFLAG

Service IP IPsec Flag

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

SERVIKEIP

Service IPv6 IKE IP eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

PATHCHK

Path Check

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1ServIP6

CNOPERATORID

CN Operator ID

eNodeB

ADD S1SERVIP6 MOD S1SERVIP6 LST S1SERVIP6

S1SigIP

CN

Cabinet No.

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SRN

Subrack No.

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SN

Slot No.

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

S1SIGIPID

S1 Signal IP ID

eNodeB

ADD S1SIGIP LST S1SIGIP MOD S1SIGIP RMV S1SIGIP

S1SigIP

LOCIP

Local IP

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

LOCIPSECFLAG

Local IPSec Flag

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

LOCIKEIP

Local IKE IP

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SECLOCIP

Second Local IP

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SECLOCIPSECFLA Second Local IPSec eNodeB G Flag

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SECLOCIKEIP

Second Local IKE IP

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

LOCPORT

Local Port No.

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

RTOMIN

RTO Min Value

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

RTOMAX

RTO Max Value

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

RTOINIT

RTO Initial Value

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

RTOALPHA

RTO Alpha Value

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

RTOBETA

RTO Beta Value

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

HBINTER

Heart-beat Interval

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

MAXASSOCRETR

Max Association Retransmission

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

MAXPATHRETR

Max Path Retransmission

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

CHKSUMTX

Transmit Message Checksum Flag

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

CHKSUMRX

Receive Message Checksum Flag

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

CHKSUMTYPE

Checksum Arithmetic Type

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SWITCHBACKFLA Switch Back Flag G

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

SWITCHBACKHBN Heart-beat Times UM When Switch Back

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

TSACK

SACK Timeout

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP

CNOPERATORID

CN Operator ID

eNodeB

ADD S1SIGIP MOD S1SIGIP LST S1SIGIP

S1SigIP6

S1SIGIP6ID

S1SigIP6 ID

eNodeB

ADD S1SIGIP6 LST S1SIGIP6 MOD S1SIGIP6 RMV S1SIGIP6

S1SigIP6

CN

Cabinet No.

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SRN

Subrack No.

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SN

Slot No.

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SIGIP1

First Local Signaling eNodeB IPv6 Address

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SIGIP1SECFLAG

First Signaling IP IPsec Flag

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SIGIKEIP

First Sigaling IPv6 IKE IP

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SIGIP2

Second Local Signaling IPv6 Address

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SIGIP2SECFLAG

Second Signaling IP eNodeB IPsec Flag

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SIGIKEIP2

Second Signaling IPv6 IKE IP

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

LOCPORT

Local Port No.

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

RTOMIN

RTO Min Value

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

RTOMAX

RTO Max Value

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

RTOINIT

RTO Initial Value

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

RTOALPHA

RTO Alpha Value

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

RTOBETA

RTO Beta Value

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

HBINTER

Heart-beat Interval

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

MAXASSOCRETR

Max Association Retransmission

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

MAXPATHRETR

Max Path Retransmission

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

CHKSUMTX

Transmit Message Checksum Flag

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

CHKSUMRX

Receive Message Checksum Flag

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6 ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

CHKSUMTYPE

Checksum Arithmetic Type

eNodeB

S1SigIP6

SWITCHBACKFLA Switch Back Flag G

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

SWITCHBACKHBN Heart-beat Times UM When Switch Back

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

S1SigIP6

CNOPERATORID

CN Operator ID

eNodeB

ADD S1SIGIP6 MOD S1SIGIP6 LST S1SIGIP6

SGW

SGWID

Service Gateway ID eNodeB

ADD SGW DSP SGW LST SGW MOD SGW RMV SGW

SGW

SERVIP1

First Service IP

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP1IPSECFL First Service IP AG IPSec Flag

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP1IKEPEER First Service IP NM IKEPeer Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

First Service IP SERVIP1IPSECPR IPsec Proposal OPNM Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP2

Second Service IP

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP2IPSECFL Second Service IP AG IPSec Flag

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP2IKEPEER Second Service IP NM IKEPeer Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

Second Service IP SERVIP2IPSECPR IPsec Proposal OPNM Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP3

Third Service IP

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP3IPSECFL Third Service IP AG IPSec Flag

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP3IKEPEER Third Service IP NM IKEPeer Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

Third Service IP SERVIP3IPSECPR IPsec Proposal OPNM Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP4

Fourth Service IP

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP4IPSECFL Fourth Service IP AG IPSec Flag

eNodeB

ADD SGW MOD SGW LST SGW

SGW

SERVIP4IKEPEER Fourth Service IP NM IKEPeer Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

Fourth Service IP SERVIP4IPSECPR IPsec Proposal OPNM Name

eNodeB

ADD SGW MOD SGW LST SGW

SGW

DESCRIPTION

Description of SGW eNodeB

ADD SGW MOD SGW LST SGW

SGW

CNOPERATORID

CN Operator ID

eNodeB

ADD SGW MOD SGW LST SGW

SGW6

SGWID

SGW6 ID

eNodeB

ADD SGW6 DSP SGW6 LST SGW6 MOD SGW6 RMV SGW6

SGW6

SERVIP1

First Service IPv6 Address

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP1IPSECFL First Service IP AG IPsec Flag

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IKEPEERNM1

First IPv6 IKEPeer Name

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IPSECPROPNM1

First IPsec Proposal eNodeB Name

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP2

Second Service IPv6 Address

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP2IPSECFL Second Service IP AG IPsec Flag

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IKEPEERNM2

Second IPv6 IKEPeer Name

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IPSECPROPNM2

Second IPsec Proposal Name

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP3

Third Service IPv6 Address

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP3IPSECFL Third Service IP AG IPsec Flag

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IKEPEERNM3

Third IPv6 IKEPeer eNodeB Name

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IPSECPROPNM3

Third IPsec Proposal Name

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP4

Fourth Service IPv6 eNodeB Address

ADD SGW6 MOD SGW6 LST SGW6

SGW6

SERVIP4IPSECFL Fourth Service IP AG IPsec Flag

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IKEPEERNM4

Fourth IPv6 IKEPeer Name

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

IPSECPROPNM4

Fourth IPsec Proposal Name

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

DESCRIPTION

Description of SGW6

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

SGW6

CNOPERATORID

CN Operator ID

eNodeB

ADD SGW6 MOD SGW6 LST SGW6

X2ServIP

CN

Cabinet No.

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

SRN

Subrack No.

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

SN

Slot No.

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

X2SERVIPID

X2 service IP ID

eNodeB

ADD X2SERVIP LST X2SERVIP MOD X2SERVIP RMV X2SERVIP

X2ServIP

X2SERVIP

X2 Service IP

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

IPSECFLAG

IPSec Flag

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

SEGWFLAG

SeGW Flag

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

LOCIKEIP

Local IKE IP

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

IKEPEERNM

IKEPeer Name

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

IPSECPROPNM

IPsec Proposal Name

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

PATHCHK

Path Check

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2ServIP

CNOPERATORID

CN Operator ID

eNodeB

ADD X2SERVIP MOD X2SERVIP LST X2SERVIP

X2SigIP

CN

Cabinet No.

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SRN

Subrack No.

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SN

Slot No.

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

X2SIGIPID

X2 signal IP ID

eNodeB

ADD X2SIGIP LST X2SIGIP MOD X2SIGIP RMV X2SIGIP

X2SigIP

LOCIP

Local IP

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

IPSECFLAG

IPSec Flag

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SEGWFLAG

SeGW Flag

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

IKEIP

Local IKE IP

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

IKEPEERNM

IKEPeer Name

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

IPSECPROPNM

IPsec Proposal Name

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SECLOCIP

Second Local IP

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SECIPSECFLAG

Second IPSec Flag eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SECSEGWFLAG

Second SeGW Flag eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SECLOCIKEIP

Second Local IKEIP eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SECIKEPEERNM

Second IKEPeer Name

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SECIPSECPROPN Second IPsec M Proposal Name

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

LOCPORT

Local Port No.

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

RTOMIN

RTO Min Value

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

RTOMAX

RTO Max Value

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

RTOINIT

RTO Initial Value

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

RTOALPHA

RTO Alpha Value

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

RTOBETA

RTO Beta Value

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

HBINTER

Heart-beat Interval

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

MAXASSOCRETR

Max Association Retransmission

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

MAXPATHRETR

Max Path Retransmission

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

CHKSUMTX

Transmit Message Checksum Flag

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

CHKSUMRX

Receive Message Checksum Flag

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

CHKSUMTYPE

Checksum Arithmetic Type

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SWITCHBACKFLA Switch Back Flag G

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

SWITCHBACKHBN Heart-beat Times UM When Switch Back

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

TSACK

SACK Timeout

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2SigIP

CNOPERATORID

CN Operator ID

eNodeB

ADD X2SIGIP MOD X2SIGIP LST X2SIGIP

X2eNodeB

X2ENODEBID

X2eNodeB ID

eNodeB

ADD X2ENODEB DSP X2ENODEB LST X2ENODEB MOD X2ENODEB RMV X2ENODEB

X2eNodeB

FIRSTSIGIP

First Signalling IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

FIRSTIPSECFLAG

First Signalling IP IPSec Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

FIRSTSEGWFLAG First SeGW Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

FIRSTIKEIP

First IKE IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SECSIGIP

Second Signalling IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SECIPSECFLAG

Second IPSec Flag eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SECSEGWFLAG

Second SeGW Flag eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SECIKEIP

Second IKE IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

APPPORT

App Port No.

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP1

First Service IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP1IPSECFL First Service IP AG IPSec Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP1SEGWFL First Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP1IKEIP

First Service IP IKE eNodeB IP

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP2

Second Service IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP2IPSECFL Second Service IP AG IPSec Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP2SEGWFL Second Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP2IKEIP

Second Service IP IKE IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP3

Third Service IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP3IPSECFL Third Service IP AG IPSecFlag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP3SEGWFL Third Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP3IKEIP

Third Service IP IKE IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP4

Fourth Service IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP4IPSECFL Fourth Service IP AG IPSec Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP4SEGWFL Fourth Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

SERVIP4IKEIP

Fourth Service IP IKE IP

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

MCC

Mobile Country Code

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

MNC

Mobile Network Code

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

ENODEBID

eNodeB ID

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

DESCRIPTION

Description of X2eNodeB

eNodeB

X2eNodeB

CNOPERATORID

CN Operator ID

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2eNodeB

TARGETENODEB RELEASE

Target eNodeB Release

eNodeB

ADD X2ENODEB MOD X2ENODEB LST X2ENODEB

X2ServIP6

X2ServIP6ID

X2ServIP6 ID

eNodeB

ADD X2SERVIP6 LST X2SERVIP6 MOD X2SERVIP6 RMV X2SERVIP6

X2ServIP6

CN

Cabinet No.

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

SRN

Subrack No.

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

SN

Slot No.

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

SERVIP

Service IP

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

SERVIPSECFLAG

Service IP IPsec Flag

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

SERVIPSECGWFL Service IP SecGW AG Flag

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

SERVIKEIP

Service IKE IP

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

IKEPEERNM

IPv6 IKEPeer Name eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

IPSECPROPNM

IPsec Proposal Name

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

PATHCHK

Path Check

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2ServIP6

CNOPERATORID

CN Operator ID

eNodeB

ADD X2SERVIP6 MOD X2SERVIP6 LST X2SERVIP6

X2SigIP6

X2SIGIP6ID

X2SigIP6 ID

eNodeB

ADD X2SIGIP6 LST X2SIGIP6 MOD X2SIGIP6 RMV X2SIGIP6

X2SigIP6

CN

Cabinet No.

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SRN

Subrack No.

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SN

Slot No.

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIP1

First Local Signaling eNodeB IPv6 Address

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIP1SECFLAG

First Signaling IP IPsec Flag

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIP1SEGWFLAG

First Signaling IP SecGW Flag

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIKEIP1

First Signaling IPv6 eNodeB IKE IP

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

IKEPEERNM1

First IPv6 IKEPeer Name

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

IPSECPROPNM1

First IPsec Proposal eNodeB Name

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIP2

Second Local Signaling IPv6 Address

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIP2SECFLAG

Second Signaling IP eNodeB IPsec Flag

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIP2SEGWFLAG

Second Signaling IP eNodeB SeGW Flag

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SIGIKEIP2

Second Signaling IPv6 IKE IP

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

IKEPEERNM2

Second IPv6 IKEPeer Name

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

IPSECPROPNM2

Second IPsec Proposal Name

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

LOCPORT

Local Port No.

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

RTOMIN

RTO Min Value

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

RTOMAX

RTO Max Value

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

RTOINIT

RTO Initial Value

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

RTOALPHA

RTO Alpha Value

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

RTOBETA

RTO Beta Value

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

HBINTER

Heart-beat Interval

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

MAXASSOCRETR

Max Association Retransmission

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

MAXPATHRETR

Max Path Retransmission

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

CHKSUMTX

Transmit Message Checksum Flag

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

CHKSUMRX

Receive Message Checksum Flag

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6 ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

CHKSUMTYPE

Checksum Arithmetic Type

eNodeB

X2SigIP6

SWITCHBACKFLA Switch Back Flag G

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

SWITCHBACKHBN Heart-beat Times UM When Switch Back

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2SigIP6

CNOPERATORID

CN Operator ID

eNodeB

ADD X2SIGIP6 MOD X2SIGIP6 LST X2SIGIP6

X2eNodeB6

X2ENODEBID

X2eNodeB6 ID

eNodeB

ADD X2ENODEB6 DSP X2ENODEB6 LST X2ENODEB6 MOD X2ENODEB6 RMV X2ENODEB6

X2eNodeB6

SIGIP1

First Signaling IPv6 eNodeB Address

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIP1SECFLAG

First Signaling IP IPsec Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIP1SEGWFLAG

First Signaling IP SeGW Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIKEIP1

First Signaling IPv6 eNodeB IKE IP

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIP2

Second Signaling IPv6 Address

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIP2SECFLAG

Second Signaling IP eNodeB IPsec Flag

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIP2SECGWFLA Second Signaling IP eNodeB G SeGW Flag

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SIGIKEIP2

Second Signaling IPv6 IKE IP

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

LOCPORT

App Port No.

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP1

First Service IPv6 Address

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP1IPSECFL First Service IP AG IPsec Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP1SECGWF First Service IP LAG SeGW Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIKEIP1

First Service IPv6 IKE IP

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP2

Second Service IPv6 Address

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP2IPSECFL Second Service IP AG IPsec Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP2SEGWFL Second Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIKEIP2

Second Service IPv6 IKE IP

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP3

Third Service IPv6 Address

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP3IPSECFL Third Service IP AG IPsec Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP3SEGWFL Third Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIKEIP3

Third Service IPv6 IKE IP

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP4

Fourth Service IPv6 eNodeB Address

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP4IPSECFL Fourth Service IP AG IPsec Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIP4SEGWFL Fourth Service IP AG SeGW Flag

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

SERVIKEIP4

Fourth Service IPv6 eNodeB IKE IP

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

MCC

Mobile Country Code

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

MNC

Mobile Network Code

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

ENODEBID

eNodeB ID

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6 ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

DESCRIPTION

Description of X2eNodeB6

eNodeB

X2eNodeB6

CNOPERATORID

CN Operator ID

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

X2eNodeB6

TARGETENODEB RELEASE

Target eNodeB Release

eNodeB

ADD X2ENODEB6 MOD X2ENODEB6 LST X2ENODEB6

CA

CANAME

Certificate Authority eNodeB Name

ADD CA LST CA MOD CA REQ DEVCERT RMV CA

CA

URL

Certificate Authority eNodeB URL

ADD CA MOD CA LST CA

CA

SIGNALG

Signature Algorithm eNodeB

ADD CA MOD CA LST CA

CERTREQ

COMMNAME

Common Name

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

USERADDINFO

Common Name Additional Info.

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

COUNTRY

Country

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

ORG

Organization

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

ORGUNIT

Organizational Unit eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

STATEPROVINCE State or Province NAME

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

LOCALITY

Locality

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

KEYUSAGE

Key Usage

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

SIGNALG

Signature Algorithm eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

KEYSIZE

Key Size

eNodeB

MOD CERTREQ UPD DEVCERT LST CERTREQ

CERTREQ

LOCALNAME

Local Name

eNodeB

MOD CERTREQ LST CERTREQ

CERTREQ

LOCALIP

Local IP

eNodeB

MOD CERTREQ LST CERTREQ

CERTMK

APPCERT

Certificate File Name

eNodeB

ADD CERTMK DSP CERTMK REQ DEVCERT RMV CERTMK UPD DEVCERT DSP CMPSESSION LST CERTMK

CERTMK

SERIALNO

Serial Number

eNodeB

DSP CERTMK

CERTMK

COMMNAME

Common Name

eNodeB

DSP CERTMK

CERTMK

ISSUER

Issuer

eNodeB

DSP CERTMK

CERTMK

DATE

Expiration Date

eNodeB

DSP CERTMK

CERTMK

EFFECTDATE

Effective Date

eNodeB

DSP CERTMK

APPCERT

APPTYPE

Application Type

eNodeB

DSP APPCERT LST APPCERT MOD APPCERT TST APPCERT LST CERTTYPE

APPCERT

APPCERT

Certificate File Name

eNodeB

MOD APPCERT TST APPCERT DSP APPCERT LST APPCERT

APPCERT

ISSUER

Issuer

eNodeB

DSP APPCERT

APPCERT

COMMNAME

Common Name

eNodeB

DSP APPCERT

APPCERT

SERIALNO

Serial Number

eNodeB

DSP APPCERT

APPCERT

DATE

Expiration Date

eNodeB

DSP APPCERT

APPCERT

IKEPEER

IKEPeer Name

eNodeB

TST APPCERT

APPCERT

EFFECTDATE

Effective Date

eNodeB

DSP APPCERT

APPCERT

STATUS

Status

eNodeB

DSP APPCERT

APPCERT

SUPPORTTYPE

Application Type Supported By NE

eNodeB

None

CROSSCERT

CERTNAME

Certificate File Name

eNodeB

ADD CROSSCERT DSP CROSSCERT RMV CROSSCERT LST CROSSCERT

CROSSCERT

SERIALNO

Serial Number

eNodeB

DSP CROSSCERT

CROSSCERT

COMMNAME

Common Name

eNodeB

DSP CROSSCERT

CROSSCERT

ISSUER

Issuer Name

eNodeB

DSP CROSSCERT

CROSSCERT

DATE

Expiring Date

eNodeB

DSP CROSSCERT

CROSSCERT

STATUS

Status

eNodeB

DSP CROSSCERT

CROSSCERT

EFFECTDATE

Effective Date

eNodeB

DSP CROSSCERT

TRUSTCERT

CERTNAME

Certificate File Name

eNodeB

ADD TRUSTCERT DSP TRUSTCERT RMV TRUSTCERT LST TRUSTCERT

TRUSTCERT

SERIALNO

Serial Number

eNodeB

DSP TRUSTCERT

TRUSTCERT

COMMNAME

Common Name

eNodeB

DSP TRUSTCERT

TRUSTCERT

ISSUER

Issuer Name

eNodeB

DSP TRUSTCERT

TRUSTCERT

DATE

Expiring Date

eNodeB

DSP TRUSTCERT

TRUSTCERT

STATUS

Status

eNodeB

DSP TRUSTCERT

TRUSTCERT

EFFECTDATE

Effective Date

eNodeB

DSP TRUSTCERT

CRL

CERTNAME

CRL File Name

eNodeB

ADD CRL DSP CRL RMV CRL LST CRL

CRL

STATUS

Status

eNodeB

DSP CRL

CRL CRL

ISSUER NEXTDATE

Issuer Next Update

eNodeB eNodeB

DSP CRL DSP CRL

CRL

THISDATE

This Update

eNodeB

DSP CRL

CRLTSK

IP

IP Address

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

USR

User Name

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

PWD

Password

eNodeB

ADD CRLTSK

CRLTSK

PORT

Port No.

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

FILENAME

File Name

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

ISCRLTIME

Using CRL's Next Update

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

PERIOD

CRL Updating Period

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

TSKID

Task ID

eNodeB

ADD CRLTSK LST CRLTSK RMV CRLTSK

CRLTSK

CRLGETMETHOD Access Method

eNodeB

ADD CRLTSK LST CRLTSK

CRLTSK

SEARCHDN

Distinguish Name

eNodeB

ADD CRLTSK LST CRLTSK

CERTCHKTSK

ISENABLE

Certificate Validity Period Checking

eNodeB

SET CERTCHKTSK LST CERTCHKTSK SET CERTCHKTSK LST CERTCHKTSK

CERTCHKTSK

PERIOD

Checking Period

eNodeB

CERTCHKTSK

ALMRNG

Alarm Threshold

eNodeB

SET CERTCHKTSK LST CERTCHKTSK

CERTCHKTSK

UPDATEMETHOD Update Method

eNodeB

SET CERTCHKTSK LST CERTCHKTSK

CRLPOLICY

CRLPOLICY

CRL Using Policy

eNodeB

SET CRLPOLICY LST CRLPOLICY

ACL

ACLID

ACL ID

eNodeB

ADD ACL LST ACL MOD ACL RMV ACL

ACL

ACLDESC

Description

eNodeB

ADD ACL MOD ACL LST ACL

ACL6

ACLID

IPv6 ACL ID

eNodeB

ADD ACL6 LST ACL6 MOD ACL6 RMV ACL6

ACL6

ACLDESC

Description

eNodeB

ADD ACL6 MOD ACL6 LST ACL6 ADD ACLRULE LST ACLRULE MOD ACLRULE RMV ACLRULE ADD ACLRULE LST ACLRULE MOD ACLRULE RMV ACLRULE

ACLRULE

ACLID

ACL ID

eNodeB

ACLRULE

RULEID

Rule ID

eNodeB

ACLRULE

ACTION

Action

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

PT

Protocol Type

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

SIP

Source IP Address

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE

SWC

Source Wildcard

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE

SMPT

Match Source Port

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

SOP

Source Port Operate

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

SPT1

Source Port 1

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

SPT2

Source Port 2

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

DIP

Destination IP Address

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE

DWC

Destination Wildcard

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE

DMPT

Match Destination Port

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

DOP

Destination Port Operate

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

DPT1

Destination Port 1

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

DPT2

Destination Port 2

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

MDSCP

Match DSCP

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

DSCP

DSCP

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

MFRG

Match Fragment Message

eNodeB

ADD ACLRULE LST ACLRULE

ACLRULE

VLANIDOP

VLAN ID Operate

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE

VLANID1

VLAN ID 1

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE

VLANID2

VLAN ID 2

eNodeB

ADD ACLRULE MOD ACLRULE LST ACLRULE

ACLRULE6

ACLID

IPv6 ACL ID

eNodeB

ADD ACLRULE6 LST ACLRULE6 MOD ACLRULE6 RMV ACLRULE6 ADD ACLRULE6 LST ACLRULE6 MOD ACLRULE6 RMV ACLRULE6

ACLRULE6

RULEID

IPv6 Rule ID

eNodeB

ACLRULE6

ACTION

IPv6 ACL Action

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

PT

Protocol Type

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

SIP

Source IPv6 Address

eNodeB

ADD ACLRULE6 MOD ACLRULE6 LST ACLRULE6

ACLRULE6

SPFXLEN

Source Address Prefix Length

eNodeB

ADD ACLRULE6 MOD ACLRULE6 LST ACLRULE6

ACLRULE6

SMPT

Match Source Port

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

SOP

Source Port Operate

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

SPT1

Source Port 1

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

SPT2

Source Port 2

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

DIP

Destination IPv6 Address

eNodeB

ADD ACLRULE6 MOD ACLRULE6 LST ACLRULE6

ACLRULE6

DPFXLEN

Destination Address eNodeB Prefix Length

ADD ACLRULE6 MOD ACLRULE6 LST ACLRULE6

ACLRULE6

DMPT

Match Destination Port

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

DOP

Destination Port Operate

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

DPT1

Destination Port 1

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

DPT2

Destination Port 2

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

MDSCP

Match DSCP

eNodeB

ADD ACLRULE6 LST ACLRULE6

ACLRULE6

DSCP

DSCP

eNodeB

ADD ACLRULE6 LST ACLRULE6

BFDSESSION

CN

Cabinet No.

eNodeB

ADD BFDSESSION DSP BFDSESSION MOD BFDSESSION RMV BFDSESSION LST BFDSESSION ADD BFDSESSION DSP BFDSESSION MOD BFDSESSION RMV BFDSESSION LST BFDSESSION ADD BFDSESSION DSP BFDSESSION MOD BFDSESSION RMV BFDSESSION LST BFDSESSION

BFDSESSION

SRN

Subrack No.

eNodeB

BFDSESSION

SN

Slot No.

eNodeB

BFDSESSION

BFDSN

Session ID

eNodeB

ADD BFDSESSION DSP BFDSESSION MOD BFDSESSION RMV BFDSESSION LST BFDSESSION

BFDSESSION

SRCIP

Source IP

eNodeB

ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION

BFDSESSION

DSTIP

Destination IP

eNodeB

ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION

BFDSESSION

HT

Hop Type

eNodeB

ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION

BFDSESSION

MINTI

Min TX Interval

eNodeB

ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION

BFDSESSION

MINRI

Min RX Interval

eNodeB

BFDSESSION

DM

Detection Multiplier eNodeB

BFDSESSION

CATLOG

Session Catalog

eNodeB

ADD BFDSESSION MOD BFDSESSION DSP BFDSESSION LST BFDSESSION

BFDSESSION

DSCP

DSCP

eNodeB

ADD BFDSESSION LST BFDSESSION

BFDSESSION

CLEAR

Clear Statistic

eNodeB

DSP BFDSESSION

BFDSESSION

FSMState

Session State

eNodeB

DSP BFDSESSION

BFDSESSION

ActualMode

Active Detecting Mode

eNodeB

DSP BFDSESSION

BFDSESSION

ActualMinTxInterval

Active Minimum Tx eNodeB Interval

DSP BFDSESSION

BFDSESSION

ActualMinRxInterval

Active Minimum Rx eNodeB Interval

DSP BFDSESSION

BFDSESSION

ActualDetectTime

Active Detection Time

eNodeB

DSP BFDSESSION

BFDSESSION

MyDiscreaminator

My Discriminator

eNodeB

DSP BFDSESSION

BFDSESSION

YourDiscreaminator Your Discriminator

eNodeB

DSP BFDSESSION

BFDSESSION

TxPDUCount

Number of TX PDUs

eNodeB

DSP BFDSESSION

BFDSESSION

RxPDUCount

Number of RX PDUs

eNodeB

DSP BFDSESSION

BFDSESSION

UptoDownCount

Total Number of Up eNodeB to Down Sessions

DSP BFDSESSION

BFDSESSION

Diagnostic

Session Diagnosis

eNodeB

DSP BFDSESSION

BFDSESSION

IFIndex

Interface Index

eNodeB

DSP BFDSESSION

BFDSESSION

VER

Protocol Version

eNodeB

ADD BFDSESSION MOD BFDSESSION LST BFDSESSION

CERTDEPLOY

DEPLOYTYPE

Certification Deploy eNodeB Position Type

SET CERTDEPLOY LST CERTDEPLOY

CERTDEPLOY

CN

Cabinet No.

eNodeB

SET CERTDEPLOY LST CERTDEPLOY SET CERTDEPLOY LST CERTDEPLOY SET CERTDEPLOY LST CERTDEPLOY ADD CFMBNDIP RMV CFMBNDIP LST CFMBNDIP

CERTDEPLOY

SRN

Subrack No.

eNodeB

CERTDEPLOY

SN

Slot No.

eNodeB

CFMBNDIP

MDNAME

MD Name

eNodeB

CFMBNDIP

MANAME

MA Name

eNodeB

ADD CFMBNDIP RMV CFMBNDIP LST CFMBNDIP

CFMBNDIP

RMEPID

RMEP ID

eNodeB

ADD CFMBNDIP RMV CFMBNDIP LST CFMBNDIP

CFMBNDIP

BNDIP

IP Address

eNodeB

ADD CFMBNDIP RMV CFMBNDIP LST CFMBNDIP

CFMMA

MDNAME

MD Name

eNodeB

ADD CFMMA DSP CFMMA MOD CFMMA RMV CFMMA LST CFMMA

CFMMA

MANAME

MA Name

eNodeB

ADD CFMMA DSP CFMMA MOD CFMMA RMV CFMMA LST CFMMA

CFMMA

CN

Cabinet No.

eNodeB

ADD CFMMA LST CFMMA

CFMMA

SRN

Subrack No.

eNodeB

ADD CFMMA LST CFMMA

CFMMA

SN

Slot No.

eNodeB

ADD CFMMA LST CFMMA ADD CFMMA DSP CFMMA LST CFMMA ADD CFMMA DSP CFMMA LST CFMMA

CFMMA

BNDVLAN

Binding VLAN

eNodeB

CFMMA

VLANID

VLAN ID

eNodeB

CFMMA

VLANPRI

VLAN Priority

eNodeB

ADD CFMMA MOD CFMMA DSP CFMMA LST CFMMA ADD CFMMA MOD CFMMA DSP CFMMA LST CFMMA DSP CFMMA

CFMMA

CCMINTL

CCM TX Interval

eNodeB

CFMMA

MEPNumber

Number of MEPs

eNodeB

CFMMA

RMEPNumber

Number of RMEPs

eNodeB

DSP CFMMA

CFMMA CFMMA

MEPList RMEPList

MEP List RMEP List

eNodeB eNodeB

DSP CFMMA DSP CFMMA

CFMMD

MDNAME

MD Name

eNodeB

ADD CFMMD DSP CFMMD RMV CFMMD LST CFMMD

CFMMD

LEVEL

MD Level

eNodeB

ADD CFMMD DSP CFMMD DSP CFMMA DSP CFMMEP DSP CFMRMEP LST CFMMD DSP CFMMD

CFMMD

MANumber

MA Number

eNodeB

CFMMD

MANameList

MA List

eNodeB

DSP CFMMD ACT CFMCC ADD CFMMEP DEA CFMCC DSP CFMMEP RMV CFMMEP LST CFMMEP

CFMMEP

MDNAME

MD Name

eNodeB

CFMMEP

MANAME

MA Name

eNodeB

ACT CFMCC ADD CFMMEP DEA CFMCC DSP CFMMEP RMV CFMMEP LST CFMMEP

CFMMEP

MEPID

MEP ID

eNodeB

ACT CFMCC ADD CFMMEP DEA CFMCC DSP CFMMEP RMV CFMMEP LST CFMMEP

CFMMEP

CN

Cabinet No.

eNodeB

ADD CFMMEP LST CFMMEP

CFMMEP

SRN

Subrack No.

eNodeB

ADD CFMMEP LST CFMMEP

CFMMEP

SN

Slot No.

eNodeB

ADD CFMMEP LST CFMMEP

CFMMEP

SBT

Subboard Type

eNodeB

ADD CFMMEP LST CFMMEP

CFMMEP

PT

Port Type

eNodeB

ADD CFMMEP LST CFMMEP

CFMMEP

PN

Port No.

eNodeB

ADD CFMMEP LST CFMMEP

CFMMEP

CCSW

CC Switch

eNodeB

DSP CFMMEP LST CFMMEP

CFMMEP

BindingVLAN

Binding VLAN

eNodeB

DSP CFMMEP

CFMMEP

VLANID

VLAN ID

eNodeB

DSP CFMMEP

CFMMEP

VLANPri

VLAN Priority

eNodeB

DSP CFMMEP

CFMMEP

TxCCPDU

Number of TX CCM eNodeB PDUs

DSP CFMMEP

CFMMEP

RxCCPDU

Number of RX CCM eNodeB PDUs

DSP CFMMEP

CFMMEP

TxLBPDU

Number of TX Loopback PDUs Number of RX Loopback PDUs Number of TX Link Trace PDUs

eNodeB

DSP CFMMEP

CFMMEP

RxLBPDU

eNodeB

DSP CFMMEP

CFMMEP

TxLTPDU

eNodeB

DSP CFMMEP

CFMMEP

RxLTPDU

Number of RX Link eNodeB Trace PDUs Number of TX Success CFM PDUs Number of RX Success CFM PDUs

DSP CFMMEP

CFMMEP

TxSuccCFMPDU

eNodeB

DSP CFMMEP

CFMMEP

RxSuccCFMPDU

eNodeB

DSP CFMMEP

CFMMEP

Number of TX TxDroppedCFMPD Dropped CFM U PDUs Number of RX RxDroppedCFMPD Dropped CFM U PDUs

eNodeB

DSP CFMMEP

CFMMEP

eNodeB

DSP CFMMEP

CFMRMEP

MDNAME

MD Name

eNodeB

ADD CFMRMEP DSP CFMRMEP RMV CFMRMEP LST CFMRMEP

CFMRMEP

MANAME

MA Name

eNodeB

ADD CFMRMEP DSP CFMRMEP RMV CFMRMEP LST CFMRMEP

CFMRMEP

RMEPID

RMEP ID

eNodeB

ADD CFMRMEP DSP CFMRMEP RMV CFMRMEP LST CFMRMEP

CFMRMEP

MAC

MAC Address

eNodeB

ADD CFMRMEP DSP CFMRMEP LST CFMRMEP

CFMRMEP

Status

Status Actual MAC Address

eNodeB

DSP CFMRMEP

CFMRMEP

ActualMAC

eNodeB

DSP CFMRMEP

CFMRMEP

BindingVLAN

Binding VLAN

eNodeB

DSP CFMRMEP

CFMRMEP

VLANID

VLAN ID

eNodeB

DSP CFMRMEP

CFMRMEP

RxCCMPDU

Number of RX CCM eNodeB PDUs

DSP CFMRMEP

CFMRMEP

IPNumber

Number of Bound IPs

eNodeB

DSP CFMRMEP

CFMRMEP

IPList

IP Address List

eNodeB

DSP CFMRMEP ADD DBGSVR DSP DBGSVR MOD DBGSVR RMV DBGSVR LST DBGSVR

DBGSVR

SERVICETYPE

Service Type

eNodeB

DBGSVR

SERVICEPORT

Service Port

eNodeB

ADD DBGSVR DSP DBGSVR MOD DBGSVR RMV DBGSVR LST DBGSVR

DBGSVR

SWITCH

Enable Flag

eNodeB

ADD DBGSVR MOD DBGSVR DSP DBGSVR LST DBGSVR

DEVIP

CN

Cabinet No.

eNodeB

ADD DEVIP DSP DEVIP RMV DEVIP LST DEVIP ADD DEVIP DSP DEVIP RMV DEVIP LST DEVIP ADD DEVIP DSP DEVIP RMV DEVIP LST DEVIP

DEVIP

SRN

Subrack No.

eNodeB

DEVIP

SN

Slot No.

eNodeB

DEVIP

SBT

Subboard Type

eNodeB

ADD DEVIP RMV DEVIP DSP DEVIP LST DEVIP

DEVIP

PT

Port Type

eNodeB

ADD DEVIP RMV DEVIP DSP DEVIP LST DEVIP

DEVIP

PN

Port No.

eNodeB

ADD DEVIP RMV DEVIP DSP DEVIP LST DEVIP

DEVIP

IP

IP Address

eNodeB

ADD DEVIP RMV DEVIP DSP DEVIP LST DEVIP

DEVIP

MASK

Mask

eNodeB

ADD DEVIP DSP DEVIP LST DEVIP

DEVIP6

ITFIDX

Interface Index

eNodeB

ADD DEVIP6 DSP DEVIP6 RMV DEVIP6 LST DEVIP6 ADD DEVIP6 RMV DEVIP6 DSP DEVIP6 LST DEVIP6

DEVIP6

IPV6

IPv6 Address

eNodeB

DEVIP6

PFXLEN

Prefix Length

eNodeB

ADD DEVIP6 DSP DEVIP6 LST DEVIP6

DEVIP6

AddressStatus

Address Status

eNodeB

DSP DEVIP6

DEVIP6

ValidLifetime

Valid Lifetime

eNodeB

DSP DEVIP6

DEVIP6

PreferredLifetime

Preferred Lifetime

eNodeB

DSP DEVIP6

DHCPRELAYSWITCH ES

DHCP Relay Switch eNodeB

SET DHCPRELAYSWIT CH LST DHCPRELAYSWIT CH

DHCPSVRIP

DHCPSVRIP

DHCP Server IP Address

eNodeB

ADD DHCPSVRIP RMV DHCPSVRIP LST DHCPSVRIP

DHCPSW

SWITCH

OMCH AutoEstablishment Switch

eNodeB

SET DHCPSW LST DHCPSW

DIFPRI

PRIRULE

Priority Rule

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

SIGPRI

Signaling Priority

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

OMHIGHPRI

OM High Priority

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

OMLOWPRI

OM Low Priority

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

PTPPRI

IPClock Priority

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT1PRI

User Data 1 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT1TYPE

User Data 1 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT1PRIMTH

User Data 1 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 1 Primary To DT1PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT2PRI

User Data 2 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT2TYPE

User Data 2 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT2PRIMTH

User Data 2 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 2 Primary To DT2PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT3PRI

User Data 3 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT3TYPE

User Data 3 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT3PRIMTH

User Data 3 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 3 Primary To DT3PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT4PRI

User Data 4 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT4TYPE

User Data 4 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT4PRIMTH

User Data 4 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 4 Primary To DT4PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT5PRI

User Data 5 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT5TYPE

User Data 5 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT5PRIMTH

User Data 5 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 5 Primary To DT5PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT6PRI

User Data 6 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT6TYPE

User Data 6 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT6PRIMTH

User Data 6 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 6 Primary To DT6PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT7PRI

User Data 7 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT7TYPE

User Data 7 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT7PRIMTH

User Data 7 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 7 Primary To DT7PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT8PRI

User Data 8 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT8TYPE

User Data 8 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT8PRIMTH

User Data 8 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 8 Primary To DT8PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT9PRI

User Data 9 Priority eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT9TYPE

User Data 9 Primary Transport Resource Type

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

DT9PRIMTH

User Data 9 Primary Port Load Threshold

eNodeB

SET DIFPRI LST DIFPRI

DIFPRI

User Data 9 Primary To DT9PRIMTOSECR Secondary Port ATIOTH Load Ratio Threshold

eNodeB

SET DIFPRI LST DIFPRI

DLITFCALG

BCDLITFCSW

Bit Congestion Down Link Internal eNodeB Flow Control Switch

SET DLITFCALG LST DLITFCALG

DLITFCALG

PCDLITFCSW

Packet Congestion Down Link Internal eNodeB Flow Control Switch

SET DLITFCALG LST DLITFCALG

DOT1X

CN

Cabinet No.

eNodeB

ACT DOT1X DEA DOT1X DSP DOT1X LST DOT1X

DOT1X

SRN

Subrack No.

eNodeB

ACT DOT1X DEA DOT1X DSP DOT1X LST DOT1X

DOT1X

SN

Slot No.

eNodeB

ACT DOT1X DEA DOT1X DSP DOT1X LST DOT1X

DOT1X

SBT

Subboard Type

eNodeB

ACT DOT1X DEA DOT1X DSP DOT1X LST DOT1X

DOT1X

PN

Port No.

eNodeB

ACT DOT1X DEA DOT1X DSP DOT1X LST DOT1X

DOT1X

AM

Authentic Method

eNodeB

ACT DOT1X DSP DOT1X LST DOT1X

DOT1X

APN

Abnormal Packet Number

eNodeB

DSP DOT1X

DOT1X

AFN

Fail Number

eNodeB

DSP DOT1X

DOT1X

AFR

Fail Reason

eNodeB

DSP DOT1X

DOT1X

RPN

Receive EAP Packet Number

eNodeB

DSP DOT1X

DOT1X

AR

Authentic State

eNodeB

DSP DOT1X

DOT1X

SPN

Send EAP Packet Number

eNodeB

DSP DOT1X

DOT1X

ASN

Authentic Succeed Number

eNodeB

DSP DOT1X

DSCPMAP

DSCP

Differentiated Service Codepoint

eNodeB

DSP DSCPMAP LST DSCPMAP SET DSCPMAP

DSCPMAP

VLANPRIO

VLAN Priority

eNodeB

SET DSCPMAP DSP DSCPMAP LST DSCPMAP

E1T1

CN

Cabinet No.

eNodeB

ADD E1T1 DSP E1T1 RMV E1T1 SET E1T1 LST E1T1

E1T1

SRN

Subrack No.

eNodeB

ADD E1T1 DSP E1T1 RMV E1T1 SET E1T1 LST E1T1 ADD E1T1 DSP E1T1 RMV E1T1 SET E1T1 LST E1T1 ADD E1T1 DSP E1T1 RMV E1T1 SET E1T1 LST E1T1 ADD E1T1 DSP E1T1 RMV E1T1 SET E1T1 LST E1T1

E1T1

SN

Slot No.

eNodeB

E1T1

PN

Port No.

eNodeB

E1T1

PS

Port Selection

eNodeB

E1T1

WORKMODE

Work Mode

eNodeB

ADD E1T1 SET E1T1 LST E1T1

E1T1

FRAME

Frame Format

eNodeB

ADD E1T1 SET E1T1 LST E1T1

E1T1

LNCODE

Line Code

eNodeB

ADD E1T1 SET E1T1 LST E1T1

E1T1

CLKM

Clock Mode

eNodeB

ADD E1T1 SET E1T1 DSP E1T1 LST E1T1

E1T1

LinkRunningStatus Link Running Status eNodeB

DSP E1T1

E1T1

ExecuteLinkTestFla Link Test Execution eNodeB g Status

DSP E1T1

E1T1

UsedFlag

Used Flag

eNodeB

DSP E1T1

E1T1

LoopLeftTime

Loop Left Time

eNodeB

DSP E1T1

E1T1

SBT

Subboard Type

eNodeB

ADD E1T1 DSP E1T1 RMV E1T1 SET E1T1 LST E1T1

E1T1

ActualWorkMode

Actual Work Mode

eNodeB

DSP DHCPRSLT DSP E1T1

E1T1

ActualFrameFormat

Actual Frame Format

eNodeB

DSP DHCPRSLT DSP E1T1

E1T1

ActualLineCode

Actual Line Code

eNodeB

DSP DHCPRSLT DSP E1T1

E1T1BER

BTL

E1/T1 BER Threshold Level

eNodeB

SET E1T1BER LST E1T1BER ACT ETHOAM3AH DEA ETHOAM3AH DSP ETHOAM3AH LST ETHOAM3AH ACT ETHOAM3AH DEA ETHOAM3AH DSP ETHOAM3AH LST ETHOAM3AH ACT ETHOAM3AH DEA ETHOAM3AH DSP ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

CN

Cabinet No.

eNodeB

ETHOAM3AH

SRN

Subrack No.

eNodeB

ETHOAM3AH

SN

Slot No.

eNodeB

ETHOAM3AH

SBT

Subboard Type

eNodeB

ACT ETHOAM3AH DEA ETHOAM3AH DSP ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

PT

Port Type

eNodeB

ACT ETHOAM3AH DEA ETHOAM3AH DSP ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

PN

Port No.

eNodeB

ACT ETHOAM3AH DEA ETHOAM3AH DSP ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

WORKMODE

Working Mode

eNodeB

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

DTPRD

Detection Period

eNodeB

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

PDUSIZE

PDU Size

eNodeB

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

RMTLBFLG

Loopback Flag

eNodeB

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

FLTINDFLG

Fault Report Flag

eNodeB

ACT ETHOAM3AH LST ETHOAM3AH ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

ERRFRMEVTPRD

Error Frame Event Duration

eNodeB

ETHOAM3AH

ERRFRMEVTTHD

Error Frame Event Threshold

eNodeB

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

ERRFRMSCDEVT PRD

Error Frame Seconds Summary eNodeB Event Duration

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

Error Frame ERRFRMSCDEVTT Seconds Summary eNodeB HD Event Threshold

ACT ETHOAM3AH LST ETHOAM3AH

ETHOAM3AH

FSMState

Current State

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

RxDropOAMPDUC Number of RX eNodeB ount Dropped OAMPDUs RxEventOAMPDUC Number of RX ount Event OAMPDUs

DSP ETHOAM3AH

ETHOAM3AH

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

RxFaultOAMPDUC Number of RX Fault eNodeB ount OAMPDUs Number of RX RxInfoOAMPDUCo Information unt OAMPDUs Number of RX RxLoopbackOAMP Loopback Control DUCount OAMPDUs

DSP ETHOAM3AH

ETHOAM3AH

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

RxTotalOAMPDUC Total Number of RX eNodeB ount OAMPDUs

DSP ETHOAM3AH

ETHOAM3AH

TxDropOAMPDUCo Number of TX eNodeB unt Dropped OAMPDUs

DSP ETHOAM3AH

ETHOAM3AH

TxEventOAMPDUC Number of TX ount Event OAMPDUs

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

TxFaultOAMPDUCo Number of TX Fault eNodeB unt OAMPDUs

DSP ETHOAM3AH

ETHOAM3AH

Number of TX TxInfoOAMPDUCo Information unt OAMPDUs

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

Number of TX TxLoopbackOAMP Loopback Control DUCount OAMPDUs

eNodeB

DSP ETHOAM3AH

ETHOAM3AH

TxTotalOAMPDUC Total Number of TX eNodeB ount OAMPDUs

DSP ETHOAM3AH

ETHPORT

CN

Cabinet No.

eNodeB

ADD ETHPORT DSP ETHPORT RMV ETHPORT RST ETHPORT SET ETHPORT LST ETHPORT

ETHPORT

SRN

Subrack No.

eNodeB

ADD ETHPORT DSP ETHPORT RMV ETHPORT RST ETHPORT SET ETHPORT LST ETHPORT ADD ETHPORT DSP ETHPORT RMV ETHPORT RST ETHPORT SET ETHPORT LST ETHPORT

ETHPORT

SN

Slot No.

eNodeB

ETHPORT

SBT

Subboard Type

eNodeB

ADD ETHPORT DSP ETHPORT RMV ETHPORT RST ETHPORT SET ETHPORT LST ETHPORT

ETHPORT

PN

Port No.

eNodeB

ADD ETHPORT DSP ETHPORT RMV ETHPORT RST ETHPORT SET ETHPORT LST ETHPORT

ETHPORT

PA

Port Attribute

eNodeB

ADD ETHPORT SET ETHPORT DSP DHCPRSLT DSP ETHPORT LST ETHPORT

ETHPORT

MTU

Maximum Transmission Unit

eNodeB

ADD ETHPORT SET ETHPORT DSP ETHPORT LST ETHPORT

ETHPORT

SPEED

Speed

eNodeB

ADD ETHPORT SET ETHPORT DSP DHCPRSLT LST ETHPORT

ETHPORT

DUPLEX

Duplex

eNodeB

ADD ETHPORT SET ETHPORT DSP DHCPRSLT LST ETHPORT

ETHPORT

ARPPROXY

ARP Proxy

eNodeB

ADD ETHPORT SET ETHPORT DSP ETHPORT LST ETHPORT

ETHPORT

FC

Flow Control

eNodeB

ADD ETHPORT SET ETHPORT DSP ETHPORT LST ETHPORT

ETHPORT

FERAT

MAC Frame Error Rate Occur Threshold

eNodeB

ADD ETHPORT SET ETHPORT LST ETHPORT

ETHPORT

FERDT

MAC Frame Error Rate Clear Threshold

eNodeB

ADD ETHPORT SET ETHPORT LST ETHPORT

ETHPORT

MAC

MAC Address

eNodeB

DSP ETHPORT

ETHPORT

PortStatus

Port Status

eNodeB

DSP ETHPORT

ETHPORT

LoopbackStatus

Loopback Status

eNodeB

DSP ETHPORT

ETHPORT

InLoopbackTestMo In Loopback Mode de or Not

eNodeB

DSP ETHPORT

ETHPORT

OAM3AHEnableFla Ethernet OAM 3AH eNodeB g Flag Number of RX Packets

DSP ETHPORT

ETHPORT

RxPackets

eNodeB

DSP ETHPORT

ETHPORT

RxBytes

Number of RX Bytes

eNodeB

DSP ETHPORT

ETHPORT

RxCRCError

Number of RX CRC eNodeB Error Packets

DSP ETHPORT

ETHPORT

RxFlowRate

RX Traffic

eNodeB

DSP ETHPORT

ETHPORT

TxPackets

Number of TX Packets

eNodeB

DSP ETHPORT

ETHPORT

TxBytes

Number of TX Bytes eNodeB

DSP ETHPORT

ETHPORT

TxFlowRate

TX Traffic

eNodeB

DSP ETHPORT

ETHPORT

IPNum

Number of IPs

eNodeB

DSP ETHPORT

ETHPORT

IPList

IP Address List

eNodeB

DSP ETHPORT

ETHPORT

LocCfgNegoMode

Local Configuration eNodeB Negotiation Mode Local Actual Negotiation Mode

DSP ETHPORT

ETHPORT

LocRealNegoMode

eNodeB

DSP ETHPORT

ETHPORT

LocSpeed

Local Speed

eNodeB

DSP ETHPORT

ETHPORT

LocDuplex

Local Duplex

eNodeB

DSP ETHPORT

ETHPORT

PeerNegoMode

Peer Actual Negotiation Mode

eNodeB

DSP ETHPORT

ETHPORT

PeerSpeed

Peer Speed

eNodeB

DSP ETHPORT

ETHPORT

PeerDuplex

Peer Duplex

eNodeB

DSP ETHPORT

ETHPORT

PhyLayerStat

Physical Layer Status

eNodeB

DSP ETHPORT ADD ETHTRK DSP ETHTRK MOD ETHTRK RMV ETHTRK LST ETHTRK ADD ETHTRK DSP ETHTRK MOD ETHTRK RMV ETHTRK LST ETHTRK ADD ETHTRK DSP ETHTRK MOD ETHTRK RMV ETHTRK LST ETHTRK

ETHTRK

CN

Cabinet No.

eNodeB

ETHTRK

SRN

Subrack No.

eNodeB

ETHTRK

SN

Slot No.

eNodeB

ETHTRK

TN

Trunk No.

eNodeB

ADD ETHTRK DSP ETHTRK MOD ETHTRK RMV ETHTRK LST ETHTRK

ETHTRK

LACP

Trunk Type

eNodeB

ADD ETHTRK MOD ETHTRK DSP DHCPRSLT DSP ETHTRK LST ETHTRK

ETHTRK

ARPPROXY

ARP Proxy

eNodeB

ADD ETHTRK MOD ETHTRK DSP ETHTRK LST ETHTRK

ETHTRK

SBT

Subboard Type

eNodeB

ADD ETHTRK DSP ETHTRK MOD ETHTRK RMV ETHTRK LST ETHTRK

ETHTRK

MTU

Max Transmission Unit

eNodeB

ADD ETHTRK MOD ETHTRK DSP ETHTRK LST ETHTRK

ETHTRK

EthTrunkStatus

Ethernet Trunk Status

eNodeB

DSP ETHTRK

ETHTRK

LocalMAC

Local MAC Address eNodeB

DSP ETHTRK

ETHTRK

PeerSysMAC

Peer System MAC Address

eNodeB

DSP ETHTRK

ETHTRK

EthTrunkLinkNum

Number of Ethernet eNodeB Trunk Ports

DSP ETHTRK

ETHTRK

EthTrunkLinkIDs

Ethernet Trunk Port eNodeB No.

DSP ETHTRK LST ETHTRK

ETHTRK

EthTrunkLinkUpNu Number of Active m Trunk Ports

eNodeB

DSP ETHTRK

ETHTRK

EthTrunkLinkUpIDs

Active Trunk Port No.

eNodeB

DSP ETHTRK

ETHTRK

RxPackets

Number of RX Packets

eNodeB

DSP ETHTRK

ETHTRK

RxBytes

Number of RX Bytes

eNodeB

DSP ETHTRK

ETHTRK

RxDroppedPackets

Number of RX Dropped Packets

eNodeB

DSP ETHTRK

ETHTRK

RxDroppedBytes

Number of RX Dropped Bytes

eNodeB

DSP ETHTRK

ETHTRK

TxPackets

Number of TX Packets

eNodeB

DSP ETHTRK

ETHTRK

TxBytes

Number of TX Bytes eNodeB

DSP ETHTRK

ETHTRK

TxDroppedPackets

Number of TX Dropped Packets

eNodeB

DSP ETHTRK

ETHTRK

TxDroppedBytes

Number of TX Dropped Bytes

eNodeB

DSP ETHTRK

ETHTRK

IPNum

Number of IPs

eNodeB

DSP ETHTRK

ETHTRK

IPList

IP Address List

eNodeB

DSP ETHTRK

ETHTRKLNK

CN

Cabinet No.

eNodeB

ADD ETHTRKLNK DSP ETHTRKLNK RMV ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

SRN

Subrack No.

eNodeB

ADD ETHTRKLNK DSP ETHTRKLNK RMV ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

SN

Slot No.

eNodeB

ADD ETHTRKLNK DSP ETHTRKLNK RMV ETHTRKLNK LST ETHTRKLNK ADD ETHTRKLNK DSP ETHTRKLNK RMV ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

TN

Trunk No.

eNodeB

ETHTRKLNK

PN

Ethernet Port No.

eNodeB

ADD ETHTRKLNK DSP ETHTRKLNK RMV ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

PRI

Port Priority

eNodeB

ADD ETHTRKLNK DSP ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

FLAG

Master Flag

eNodeB

ADD ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

SBT

Subboard Type

eNodeB

ADD ETHTRKLNK DSP ETHTRKLNK RMV ETHTRKLNK LST ETHTRKLNK

ETHTRKLNK

PortStatus

Port Status

eNodeB

DSP ETHTRKLNK

ETHTRKLNK

MAC

MAC Address

eNodeB

DSP ETHTRKLNK

ETHTRKLNK

LocalTimeoutMode

Local Timeout Mode

eNodeB

DSP ETHTRKLNK

ETHTRKLNK

PeerTimeoutMode

Peer Timeout Mode eNodeB

DSP ETHTRKLNK

ETHTRKLNK

RxLACPPackets

Number of RX LACP Packets

eNodeB

DSP ETHTRKLNK

ETHTRKLNK

TxLACPPackets

Number of TX LACP Packets

eNodeB

DSP ETHTRKLNK

EXTUDT

EXTUDTNO

User Data Type Number

eNodeB

ADD EXTUDT MOD EXTUDT RMV EXTUDT LST EXTUDT

EXTUDT

Extern User Data EXTUDTPARAGRP Type Transfer ID Parameter Group ID.

eNodeB

ADD EXTUDT MOD EXTUDT LST EXTUDT

Extern User Data EXTUDTPARAGRP Type Transfer EXTUDTPARAGRP ID Parameter Group ID.

eNodeB

ADD EXTUDTPARAGRP LST EXTUDTPARAGRP MOD EXTUDTPARAGRP RMV EXTUDTPARAGRP

EXTUDTPARAGRP PRI

Priority

eNodeB

ADD EXTUDTPARAGRP MOD EXTUDTPARAGRP LST EXTUDTPARAGRP

EXTUDTPARAGRP ACTFACTOR

Act Factor

eNodeB

ADD EXTUDTPARAGRP MOD EXTUDTPARAGRP LST EXTUDTPARAGRP

EXTUDTPARAGRP

PRIMTRANRSCTY Primary Transport PE Resource Type

eNodeB

ADD EXTUDTPARAGRP MOD EXTUDTPARAGRP LST EXTUDTPARAGRP

EXTUDTPARAGRP PRIMPTLOADTH

Primary Port Load Threshold

eNodeB

ADD EXTUDTPARAGRP MOD EXTUDTPARAGRP LST EXTUDTPARAGRP

Primary To PRIM2SECPTLOA Secondary Port EXTUDTPARAGRP DRATH Load Ratio Threshold

eNodeB

ADD EXTUDTPARAGRP MOD EXTUDTPARAGRP LST EXTUDTPARAGRP

FLOODDEFEND

FLDTYPE

Flood Type

eNodeB

ADD FLOODDEFEND DSP FLOODDEFEND MOD FLOODDEFEND RMV FLOODDEFEND LST FLOODDEFEND ADD FLOODDEFEND MOD FLOODDEFEND LST FLOODDEFEND

FLOODDEFEND

DFDSW

Defend Switch

eNodeB

FLOODDEFEND

DFDTHD

Defend Threshold

eNodeB

ADD FLOODDEFEND MOD FLOODDEFEND LST FLOODDEFEND

FLOODDEFEND

ALMSW

Alarm Switch

eNodeB

ADD FLOODDEFEND MOD FLOODDEFEND LST FLOODDEFEND

FLOODDEFEND

ALMTHD

Alarm Threshold

eNodeB

ADD FLOODDEFEND MOD FLOODDEFEND LST FLOODDEFEND

FLOODDEFEND

Packets

Number of Flood Droped Packets

eNodeB

DSP FLOODDEFEND

FLOODDEFEND

RcvTotalPkt

Receive Total packets

eNodeB

DSP FLOODDEFEND

GTRANSPARA

LPSCHSW

Resource Group Scheduling Weight eNodeB Switch

SET GTRANSPARA LST GTRANSPARA

GTRANSPARA

RATECFGTYPE

Rate Config Type

eNodeB

SET GTRANSPARA LST GTRANSPARA

GTRANSPARA

SBTIME

Switch Back Time

eNodeB

SET GTRANSPARA LST GTRANSPARA

IKECFG

IKELNM

Local Name

eNodeB

SET IKECFG DSP IKECFG LST IKECFG

IKECFG

IKEKLI

Keepalive Interval

eNodeB

SET IKECFG DSP IKECFG LST IKECFG

IKECFG

IKEKLT

Keepalive Timeout

eNodeB

SET IKECFG DSP IKECFG LST IKECFG

IKECFG

DSCP

DSCP

eNodeB

SET IKECFG DSP IKECFG LST IKECFG DSP IKECFG

IKECFG

CabinetNo

Cabinet No.

eNodeB

IKECFG

SubrackNo

Subrack No.

eNodeB

DSP IKECFG

IKECFG

SlotNo

Slot No.

eNodeB

DSP IKECFG

IKEPEER

PEERNAME

IKE Peer Name

eNodeB

ADD IKEPEER DSP IKEPEER LST IKEPEER MOD IKEPEER RMV IKEPEER

IKEPEER

PROPID

IKE Proposal ID

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

IKEVERSION

Version

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

EXCHMODE

Exchange Mode

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

IDTYPE

Local ID Type

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

REMOTEIP

Remote IP Address eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

REMOTENAME

Remote Name

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

PKEY

Pre-shared Key

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

DPD

DPD Mode

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

DPDIDLETIME

DPD Idle Time

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

DPDRETRI

DPD Retransmission Interval

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

DPDRETRN

DPD Retransmission Count

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

LOCALIP

Local IP Address

eNodeB

ADD IKEPEER MOD IKEPEER DSP IKEPEER LST IKEPEER

IKEPEER

CabinetNo

Cabinet No.

eNodeB

DSP IKEPEER

IKEPEER

SubrackNo

Subrack No.

eNodeB

DSP IKEPEER

IKEPEER

SlotNo

Slot No.

eNodeB

DSP IKEPEER

IKEPEER6

PEERNAME

IPv6 IKE Peer Name

eNodeB

ADD IKEPEER6 DSP IKEPEER6 LST IKEPEER6 MOD IKEPEER6 RMV IKEPEER6

IKEPEER6

PROPID

IKE Proposal ID

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

IKEVERSION

Version

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

EXCHMODE

Exchange Mode

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

IDTYPE

Local ID Type

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

REMOTEIP

Remote IPv6 Address

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

REMOTENAME

Remote Name

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

PKEY

Pre-shared Key

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

DPD

DPD Mode

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

DPDIDLETIME

DPD Idle Time

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

DPDRETRI

DPD Retransmission Interval

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

DPDRETRN

DPD Retransmission Count

eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

LOCALIP

Local IPv6 Address eNodeB

ADD IKEPEER6 MOD IKEPEER6 DSP IKEPEER6 LST IKEPEER6

IKEPEER6

CabinetNo

Cabinet No.

eNodeB

DSP IKEPEER6

IKEPEER6

SubrackNo

Subrack No.

eNodeB

DSP IKEPEER6

IKEPEER6

SlotNo

Slot No.

eNodeB

DSP IKEPEER6

IKEPROPOSAL

PROPID

Proposal ID

eNodeB

ADD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL MOD IKEPROPOSAL RMV IKEPROPOSAL

IKEPROPOSAL

ENCALG

Encryption Algorithm

eNodeB

ADD IKEPROPOSAL MOD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL

IKEPROPOSAL

AUTHALG

Authentication Algorithm

eNodeB

ADD IKEPROPOSAL MOD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL

IKEPROPOSAL

AUTHMETH

Authentication Method

eNodeB

ADD IKEPROPOSAL MOD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL

IKEPROPOSAL

DHGRP

Diffie-Hellman Group

eNodeB

ADD IKEPROPOSAL MOD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL

IKEPROPOSAL

DURATION

ISAKMP SA Duration

eNodeB

ADD IKEPROPOSAL MOD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL

IKEPROPOSAL

PRFALG

PRF Algorithm

eNodeB

ADD IKEPROPOSAL MOD IKEPROPOSAL DSP IKEPROPOSAL LST IKEPROPOSAL

IKEPROPOSAL

CabinetNo

Cabinet No.

eNodeB

DSP IKEPROPOSAL

IKEPROPOSAL

SubrackNo

Subrack No.

eNodeB

DSP IKEPROPOSAL

IKEPROPOSAL

SlotNo

Slot No.

eNodeB

DSP IKEPROPOSAL

IP2RSCGRP

CN

Cabinet No.

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

SRN

Subrack No.

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

SN

Slot No.

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

RSCGRPID

Transmission eNodeB Resource Group ID

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

DSTIP

Destination IP

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

DSTMASK

Mask

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

BEAR

Transmission Resource Group Bear Type

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

SBT

Subboard Type

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

PT

Bearing Port Type

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IP2RSCGRP

PN

Bearing Port No.

eNodeB

ADD IP2RSCGRP RMV IP2RSCGRP LST IP2RSCGRP

IPGUARD

ARPSPOOFCHKS W

ARP Spoofing Check Switch

eNodeB

SET IPGUARD LST IPGUARD

IPGUARD

ARPSPOOFALMTH ARP Spoofing D Alarm Threshold

eNodeB

SET IPGUARD LST IPGUARD

IPGUARD

ARPLRNSTRICTS W

ARP Learning Strict eNodeB Switch

SET IPGUARD LST IPGUARD

IPGUARD

INVALIDPKTCHKS Invalid Packet W Check Switch

eNodeB

SET IPGUARD LST IPGUARD

IPGUARD

INVALIDPKTALMT Alarm Threshold HD

eNodeB

SET IPGUARD LST IPGUARD

IPGUARD

IPSECREPLAYCH IPSec Replay Alarm eNodeB KSW Switch

SET IPGUARD LST IPGUARD

IPGUARD

IPSECREPLAYAL MTHD

IPSec Replay Alarm eNodeB Threshold

SET IPGUARD LST IPGUARD

IPGUARD

PT

Port Type

eNodeB

DSP INVALIDPKTINFO

IPGUARD IPGUARD

PN SrcMacAddr

Port No. Source MAC Address of Invalid Packet Destination MAC Address of Invalid Packet VLAN ID of Invalid Packet

eNodeB eNodeB

DSP INVALIDPKTINFO DSP INVALIDPKTINFO DSP INVALIDPKTINFO DSP INVALIDPKTINFO

IPGUARD

DstMacAddr

eNodeB

IPGUARD

VlanID

eNodeB

IPGUARD

MacLayerProtocol

Protocol Type of MAC Layer

eNodeB

DSP INVALIDPKTINFO

IPGUARD

SrcIP

Source IP Address of Invalid Packet Destination IP Address of Invalid Packet

eNodeB

DSP INVALIDPKTINFO DSP INVALIDPKTINFO

IPGUARD

DstIP

eNodeB

IPGUARD

IPLayerProtocol

Protocol Type of IP eNodeB Layer

DSP INVALIDPKTINFO

IPGUARD

SrcPort

Source Port of Invalid Packet Destination Port of Invalid Packet

eNodeB

DSP INVALIDPKTINFO DSP INVALIDPKTINFO DSP INVALIDPKTINFO ADD IPITF6 DSP IPITF6 RMV IPITF6 LST IPITF6 ADD IPITF6 DSP IPITF6 LST IPITF6

IPGUARD

DstPort

eNodeB

IPGUARD

PacketData

Invalid Packet Data eNodeB

IPITF6

ITFIDX

Interface Index

eNodeB

IPITF6

ITFTYPE

Interface Type

eNodeB

IPITF6

CN

Cabinet No.

eNodeB

ADD IPITF6 DSP IPITF6 LST IPITF6

IPITF6

SRN

Subrack No.

eNodeB

ADD IPITF6 DSP IPITF6 LST IPITF6 ADD IPITF6 DSP IPITF6 LST IPITF6 ADD IPITF6 DSP IPITF6 LST IPITF6

IPITF6

SN

Slot No.

eNodeB

IPITF6

SBT

Subboard Type

eNodeB

IPITF6

PT

Port Type

eNodeB

ADD IPITF6 DSP IPITF6 LST IPITF6

IPITF6

PN

Port No.

eNodeB

ADD IPITF6 DSP IPITF6 LST IPITF6

IPITF6

VLANID

VLAN ID

eNodeB

ADD IPITF6 DSP IPITF6 LST IPITF6 ADD IPITF6 DSP IPITF6 LST IPITF6 DSP IPITF6

IPITF6

MTU

Maximum Transmission Unit

eNodeB

IPITF6

ItfStatus

Interface Status

eNodeB

IPITF6

LinkLocalAddr

Link Local Address eNodeB

DSP IPITF6

IPITF6

GlobalAddrNum

Global Unicast Address Number

eNodeB

DSP IPITF6

IPITF6

GlobalAddr

Global Unicast Address(es)

eNodeB

DSP IPITF6

IPITF6

MulticastAddrNum

Multicast Address Number

eNodeB

DSP IPITF6

IPITF6

MulticastAddr

Multicast Address(es)

eNodeB

DSP IPITF6

IPITF6

NDAddrConfictChe ND DAD ck

eNodeB

DSP IPITF6

IPITF6

NDAttempts

ND DAD Attempts Number

eNodeB

DSP IPITF6

IPITF6

NDReachableTime ND Reachable Time eNodeB

DSP IPITF6

IPITF6

NDRetransInterval

ND Retransmit Interval

eNodeB

DSP IPITF6

IPITF6

LinkLocalAddrAuto Link Local Address eNodeB Config Autoconfig

DSP IPITF6

IPITF6

StatelessAutoConfi Stateless g Autoconfig

eNodeB

DSP IPITF6 ADD IPPATH DSP IPPATH LST IPPATH MOD IPPATH RMV IPPATH ADD IPPATH MOD IPPATH LST IPPATH ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

PATHID

IP Path ID

eNodeB

IPPATH

CN

Cabinet No.

eNodeB

IPPATH

SRN

Subrack No.

eNodeB

IPPATH

SN

Slot No.

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

PT

Port Type

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

PN

Port No.

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

PATHTYPE

Path Type

eNodeB

ADD IPPATH LST IPPATH

IPPATH

DSCP

DSCP

eNodeB

ADD IPPATH LST IPPATH

IPPATH

LOCALIP

Local IP

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

PEERIP

Peer IP

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

ANI

Adjacent Node ID

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

QT

Transport Resource eNodeB Type

ADD IPPATH MOD IPPATH DSP IPPATH LST IPPATH

IPPATH

APPTYPE

Application Type

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

PATHCHK

Path Check

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

RealtimeTxBandwid Realtime TX th Bandwidth

eNodeB

DSP IPPATH

IPPATH

RealtimeRxBandwid Realtime RX th Bandwidth

eNodeB

DSP IPPATH

IPPATH

NonRealtimeTxBan Non-Realtime TX dwidth Bandwidth

eNodeB

DSP IPPATH

IPPATH

NonRealtimeRxBan Non-Realtime RX dwidth Bandwidth

eNodeB

DSP IPPATH

IPPATH

Non-Realtime NonRealtimeReserv Reserved TX edTxBandwidth Bandwidth

eNodeB

DSP IPPATH

IPPATH

Non-Realtime NonRealtimeReserv Reserved RX edRxBandwidth Bandwidth

eNodeB

DSP IPPATH

IPPATH

IppathCheckResult

IP Path Check Result

eNodeB

DSP IPPATH

IPPATH

RSCGRPID

Transmission eNodeB Resource Group ID

ADD IPPATH MOD IPPATH LST IPPATH ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

DESCRI

Description Info

eNodeB

IPPATH

SBT

Subboard Type

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH

JNRSCGRP

Join Transmission Resource Group

eNodeB

ADD IPPATH MOD IPPATH LST IPPATH

IPPATH6

PATHID

IPv6 Path ID

eNodeB

ADD IPPATH6 DSP IPPATH6 MOD IPPATH6 RMV IPPATH6 LST IPPATH6 ADD IPPATH6 LST IPPATH6

IPPATH6

JNRSCGRP

Join Transmission Resource Group

eNodeB

IPPATH6

RSCGRPID

Transmission eNodeB Resource Group ID

ADD IPPATH6 LST IPPATH6

IPPATH6

ITFIDX

Interface Index

eNodeB

ADD IPPATH6 LST IPPATH6

IPPATH6

PATHTYPE

Path Type

eNodeB

ADD IPPATH6 LST IPPATH6

IPPATH6

DSCP

DSCP

eNodeB

ADD IPPATH6 LST IPPATH6

IPPATH6

LOCALIP6

Local IPv6 Address eNodeB

ADD IPPATH6 LST IPPATH6

IPPATH6

PEERIP6

Peer IPv6 Address

eNodeB

ADD IPPATH6 LST IPPATH6

IPPATH6

ANI

Adjacent Node ID

eNodeB

ADD IPPATH6 MOD IPPATH6 LST IPPATH6

IPPATH6

APPTYPE

Application Type

eNodeB

ADD IPPATH6 MOD IPPATH6 LST IPPATH6

IPPATH6

PATHCHK

Path Check

eNodeB

ADD IPPATH6 MOD IPPATH6 LST IPPATH6

IPPATH6

RealtimeTxBandwid Realtime TX th Bandwidth

eNodeB

DSP IPPATH6

IPPATH6

RealtimeRxBandwid Realtime RX th Bandwidth

eNodeB

DSP IPPATH6

IPPATH6

NonRealtimeTxBan Non-Realtime TX dwidth Bandwidth

eNodeB

DSP IPPATH6

IPPATH6

NonRealtimeRxBan Non-Realtime RX dwidth Bandwidth

eNodeB

DSP IPPATH6

IPPATH6

Non-Realtime NonRealtimeReserv Reserved TX edTxBandwidth Bandwidth

eNodeB

DSP IPPATH6

IPPATH6

Non-Realtime NonRealtimeReserv Reserved RX edRxBandwidth Bandwidth

eNodeB

DSP IPPATH6

IPPATH6

IppathCheckResult

IPv6 Path Check Result

eNodeB

DSP IPPATH6

IPPATH6

DESCRI

Description Info

eNodeB

ADD IPPATH6 MOD IPPATH6 LST IPPATH6

IPPATHRT

SRCIP

Source IP

eNodeB

ADD IPPATHRT DSP IPPATHRT RMV IPPATHRT LST IPPATHRT

IPPATHRT

DSTIP

Destination IP

eNodeB

ADD IPPATHRT DSP IPPATHRT RMV IPPATHRT LST IPPATHRT

IPPATHRT

TRANRSCTYPE

Transport Resource eNodeB Type

ADD IPPATHRT DSP IPPATHRT LST IPPATHRT

IPPATHRT

NEXTHOPIP

Next Hop IP

eNodeB

ADD IPPATHRT DSP IPPATHRT LST IPPATHRT

IPPMSESSION

IPPMSN

IP PM Session ID

eNodeB

ADD IPPMSESSION DSP IPPMSESSION RMV IPPMSESSION LST IPPMSESSION

IPPMSESSION

LOCALIP

Local IP

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION

IPPMSESSION

PEERIP

Peer IP

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION

IPPMSESSION

IPPMDSCP

DSCP

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION

IPPMSESSION

DIR

Activate Direction

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION

IPPMSESSION

TimeDelay

Round Trip Time

eNodeB

DSP IPPMSESSION

IPPMSESSION

RxJitter

RX Jitter

eNodeB

DSP IPPMSESSION

IPPMSESSION

TxJitter

TX Jitter

eNodeB

DSP IPPMSESSION

IPPMSESSION

RxLossRate

RX Loss Rate

eNodeB

DSP IPPMSESSION

IPPMSESSION

TxLossRate

TX Loss Rate

eNodeB

DSP IPPMSESSION

IPPMSESSION

IppmUpActState

Activate State(Up)

eNodeB

DSP IPPMSESSION

IPPMSESSION

IppmDownActState

Activate State(Down)

eNodeB

DSP IPPMSESSION

IPPMSESSION

IPPMTYPE

IP PM Type

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION

IPPMSESSION

BINDPATH

Bind IP Path

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION

IPPMSESSION

PATHID

IP Path ID

eNodeB

ADD IPPMSESSION DSP IPPMSESSION LST IPPMSESSION DSP IPPMSESSION DSP IPPMSESSION DSP IPPMSESSION

IPPMSESSION

DLDscpChangeFlag

DSCP Change Flag(Down) DSCP Initial Value(Down) DSCP Changed Value(Down)

eNodeB

IPPMSESSION

DLPreDscp

eNodeB

IPPMSESSION

DLModiDscp

eNodeB

IPPMSESSION

DSCP Changed DLDscpChangeDat Date And eTime Time(Down) DSCP Change Flag(Up)

eNodeB

DSP IPPMSESSION

IPPMSESSION

ULDscpChangeFlag

eNodeB

DSP IPPMSESSION

IPPMSESSION

ULPreDscp

DSCP Initial Value(Up) DSCP Changed Value(Up)

eNodeB

DSP IPPMSESSION DSP IPPMSESSION

IPPMSESSION

ULModiDscp

eNodeB

IPPMSESSION

ULDscpChangeDat DSCP Changed eNodeB eTime Date And Time(Up)

DSP IPPMSESSION

IPPMSESSION

VER

IP PM Protocol Version

eNodeB

DSP IPPMSESSION

IPRT

CN

Cabinet No.

eNodeB

ADD IPRT DSP IPRT MOD IPRT RMV IPRT LST IPRT ADD IPRT DSP IPRT MOD IPRT RMV IPRT LST IPRT ADD IPRT DSP IPRT MOD IPRT RMV IPRT LST IPRT

IPRT

SRN

Subrack No.

eNodeB

IPRT

SN

Slot No.

eNodeB

IPRT

SBT

Subboard Type

eNodeB

ADD IPRT MOD IPRT RMV IPRT LST IPRT

IPRT

IFT

Port Type

eNodeB

ADD IPRT MOD IPRT RMV IPRT LST IPRT

IPRT

IFNO

Port No.

eNodeB

ADD IPRT MOD IPRT RMV IPRT LST IPRT

IPRT

RTTYPE

Route Type

eNodeB

ADD IPRT MOD IPRT RMV IPRT DSP IPRT LST IPRT

IPRT

DSTIP

Destination IP

eNodeB

ADD IPRT MOD IPRT RMV IPRT DSP IPRT LST IPRT

IPRT

DSTMASK

Mask

eNodeB

ADD IPRT MOD IPRT RMV IPRT DSP IPRT LST IPRT

IPRT

NEXTHOP

Next Hop IP

eNodeB

ADD IPRT MOD IPRT RMV IPRT DSP IPRT LST IPRT

IPRT

PREF

Preference

eNodeB

ADD IPRT MOD IPRT DSP IPRT LST IPRT

IPRT

RTRouteType

Protocol

eNodeB

DSP IPRT

IPRT

DESCRI

Description Info

eNodeB

ADD IPRT MOD IPRT LST IPRT

IPRT

ActualPortType

Actual Port Type

eNodeB

DSP IPRT

IPRT

ActualPortNo

Actual Port No.

eNodeB

DSP IPRT

IPRT6

DSTIP

Destination IPv6 Address

eNodeB

ADD IPRT6 MOD IPRT6 RMV IPRT6 DSP IPRT6 LST IPRT6

IPRT6

PFXLEN

Prefix Length

eNodeB

ADD IPRT6 MOD IPRT6 RMV IPRT6 DSP IPRT6 LST IPRT6

IPRT6

RTTYPE

Route Type

eNodeB

ADD IPRT6 MOD IPRT6 RMV IPRT6 DSP IPRT6 LST IPRT6

IPRT6

NEXTHOPIP6TYPE Next Hop IPv6 Type eNodeB

ADD IPRT6 MOD IPRT6 RMV IPRT6 LST IPRT6

IPRT6

NEXTHOPIP

Next Hop IPv6 Address

eNodeB

ADD IPRT6 MOD IPRT6 RMV IPRT6 DSP IPRT6 LST IPRT6 ADD IPRT6 MOD IPRT6 RMV IPRT6 DSP IPRT6 LST IPRT6 ADD IPRT6 MOD IPRT6 DSP IPRT6 LST IPRT6

IPRT6

ITFIDX

Interface Index

eNodeB

IPRT6

PREF

Preference

eNodeB

IPRT6

RTRouteType

Protocol

eNodeB

DSP IPRT6

IPRT6

DESCRI

Description Info

eNodeB

ADD IPRT6 MOD IPRT6 LST IPRT6 ADD IPSECBIND RMV IPSECBIND LST IPSECBIND

IPSECBIND

CN

Cabinet No.

eNodeB

IPSECBIND

SRN

Subrack No.

eNodeB

ADD IPSECBIND RMV IPSECBIND LST IPSECBIND

IPSECBIND

SN

Slot No.

eNodeB

ADD IPSECBIND RMV IPSECBIND LST IPSECBIND

IPSECBIND

SBT

Subboard Type

eNodeB

ADD IPSECBIND RMV IPSECBIND LST IPSECBIND

IPSECBIND

PT

Port Type

eNodeB

ADD IPSECBIND RMV IPSECBIND LST IPSECBIND

IPSECBIND

PN

Port No.

eNodeB

ADD IPSECBIND RMV IPSECBIND LST IPSECBIND

IPSECBIND

SPGN

Policy Group Name eNodeB

ADD IPSECBIND LST IPSECBIND ADD IPSECBIND6 RMV IPSECBIND6 LST IPSECBIND6

IPSECBIND6

ITFIDX

Interface Index

eNodeB

IPSECBIND6

SPGN6

IPv6 IPSec Policy Group Name

eNodeB

ADD IPSECBIND6 LST IPSECBIND6

IPSECDTNL

DUALID

IPSec Dual Tunnel ID

eNodeB

ADD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL MOD IPSECDTNL RMV IPSECDTNL

IPSECDTNL

MSPGN

Master Policy Group Name

eNodeB

ADD IPSECDTNL MOD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL

IPSECDTNL

MSPSN

Master IPSec Sequence No.

eNodeB

ADD IPSECDTNL MOD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL

IPSECDTNL

SSPGN

Slave Policy Group eNodeB Name

ADD IPSECDTNL MOD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL

IPSECDTNL

SSPSN

Slave IPSec Sequence No.

eNodeB

ADD IPSECDTNL MOD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL

IPSECDTNL

MBFDSN

Master Tunnel's BFD Session ID

eNodeB

ADD IPSECDTNL MOD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL

IPSECDTNL

SBFDSN

Slave Tunnel's BFD eNodeB Session ID

ADD IPSECDTNL MOD IPSECDTNL DSP IPSECDTNL LST IPSECDTNL

IPSECDTNL

CurrentUsedTunnel

Current Used IPSec eNodeB Policy

DSP IPSECDTNL

IPSECPOLICY

SPGN

Policy Group Name eNodeB

ADD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY MOD IPSECPOLICY RMV IPSECPOLICY ADD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY MOD IPSECPOLICY RMV ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY

IPSECPOLICY

SPSN

IPSec Sequence No.

eNodeB

IPSECPOLICY

ACLID

ACL ID

eNodeB

IPSECPOLICY

PROPNAME

IPSec Proposal Name

eNodeB

IPSECPOLICY

PEERNAME

IKE Peer Name

eNodeB

IPSECPOLICY

PFS

Perfect Forward Secrecy

eNodeB

ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY

IPSECPOLICY

LTCFG

SA Duration Mode

eNodeB

ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY

IPSECPOLICY

LTS

Lifetime Based On Time

eNodeB

ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY

IPSECPOLICY

LTKB

Lifetime Based On Traffic

eNodeB

ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY DSP IPSECPOLICY

IPSECPOLICY

CabinetNo

Cabinet No.

eNodeB

IPSECPOLICY

SubrackNo

Subrack No.

eNodeB

DSP IPSECPOLICY

IPSECPOLICY

SlotNo

Slot No.

eNodeB

DSP IPSECPOLICY

IPSECPOLICY

REPLAYWND

Anti-Replay Window eNodeB Size

ADD IPSECPOLICY MOD IPSECPOLICY DSP IPSECPOLICY LST IPSECPOLICY

IPSECPOLICY6

SPGN

IPv6 Policy Group Name

eNodeB

ADD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6 MOD IPSECPOLICY6 RMV IPSECPOLICY6 ADD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6 MOD IPSECPOLICY6 RMV IPSECPOLICY6

IPSECPOLICY6

SPSN

IPv6 IPSec Sequence No.

eNodeB

IPSECPOLICY6

ACLTYPE

ACL Type

eNodeB

ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6 ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6 ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6 ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6 ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6

IPSECPOLICY6

ACLID

IPv4 ACL ID

eNodeB

IPSECPOLICY6

ACL6ID

IPv6 ACL ID

eNodeB

IPSECPOLICY6

PROPNAME

IPSec Proposal Name

eNodeB

IPSECPOLICY6

PEER6NAME

IPv6 IKE Peer Name

eNodeB

IPSECPOLICY6

PFS

Perfect Forward Secrecy

eNodeB

ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6

IPSECPOLICY6

LTCFG

IPv6 SA Duration Mode

eNodeB

ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6

IPSECPOLICY6

LTS

Lifetime Based On Time

eNodeB

ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6

IPSECPOLICY6

LTKB

Lifetime Based On Traffic

eNodeB

ADD IPSECPOLICY6 MOD IPSECPOLICY6 DSP IPSECPOLICY6 LST IPSECPOLICY6

IPSECPOLICY6

CabinetNo

Cabinet No.

eNodeB

DSP IPSECPOLICY6

IPSECPOLICY6

SubrackNo

Subrack No.

eNodeB

DSP IPSECPOLICY6

IPSECPOLICY6

SlotNo

Slot No.

eNodeB

DSP IPSECPOLICY6 ADD IPSECPROPOSAL DSP IPSECPROPOSAL LST IPSECPROPOSAL MOD IPSECPROPOSAL RMV IPSECPROPOSAL

IPSECPROPOSAL PROPNAME

IPSec Proposal Name

eNodeB

IPSECPROPOSAL ENCAPMODE

Encapsulation Mode

eNodeB

ADD IPSECPROPOSAL MOD IPSECPROPOSAL DSP IPSECPROPOSAL LST IPSECPROPOSAL

IPSECPROPOSAL TRANMODE

Transform

eNodeB

ADD IPSECPROPOSAL MOD IPSECPROPOSAL DSP IPSECPROPOSAL LST IPSECPROPOSAL

IPSECPROPOSAL AHAUTHALG

AH Authentication Algorithm

eNodeB

ADD IPSECPROPOSAL MOD IPSECPROPOSAL DSP IPSECPROPOSAL LST IPSECPROPOSAL

IPSECPROPOSAL ESPAUTHALG

ESP Authentication eNodeB Algorithm

ADD IPSECPROPOSAL MOD IPSECPROPOSAL DSP IPSECPROPOSAL LST IPSECPROPOSAL

IPSECPROPOSAL ESPENCALG

ESP Encryption Algorithm

eNodeB

ADD IPSECPROPOSAL MOD IPSECPROPOSAL DSP IPSECPROPOSAL LST IPSECPROPOSAL

IPSECPROPOSAL CabinetNo

Cabinet No.

eNodeB

DSP IPSECPROPOSAL

IPSECPROPOSAL SubrackNo

Subrack No.

eNodeB

DSP IPSECPROPOSAL

IPSECPROPOSAL SlotNo

Slot No.

eNodeB

DSP IPSECPROPOSAL

LOCALETHPORT

ConfigStatus

Config Status

eNodeB

DSP LOCALETHPORT

LOCALETHPORT

PortStatus

Port Status

eNodeB

DSP LOCALETHPORT

LOCALETHPORT

RxDropped

Number of RX Discarded Packets

eNodeB

DSP LOCALETHPORT

LOCALETHPORT

RxPackets

Number of RX Packets

eNodeB

DSP LOCALETHPORT

LOCALETHPORT

TxDropped

Number of TX Discarded Packets

eNodeB

DSP LOCALETHPORT

LOCALETHPORT

TxPackets

Number of TX Packets

eNodeB

DSP LOCALETHPORT

LOCALIP

IP

IP Address

eNodeB

SET LOCALIP DSP LOCALIP LST LOCALIP

LOCALIP

MASK

Mask

eNodeB

SET LOCALIP DSP LOCALIP LST LOCALIP

LOCALIP6

IP6

IPv6 Address

eNodeB

SET LOCALIP6 DSP LOCALIP6 LST LOCALIP6

LOCALIP6

PFXLEN

Prefix Length

eNodeB

SET LOCALIP6 DSP LOCALIP6 LST LOCALIP6

LOCALIP6

AddressStatus

Address Status

eNodeB

DSP LOCALIP6

LOCALIP6

ValidLifetime

Valid Lifetime

eNodeB

DSP LOCALIP6

LOCALIP6

PreferredLifetime

Preferred Lifetime

eNodeB

DSP LOCALIP6

LR

CN

Cabinet No.

eNodeB

SET LR LST LR

LR

SRN

Subrack No.

eNodeB

SET LR LST LR

LR

SN

Slot No.

eNodeB

SET LR LST LR

LR

PT

Port Type

eNodeB

SET LR LST LR

LR

PN

Port No.

eNodeB

SET LR LST LR

LR

LRSW

LR Switch

eNodeB

SET LR LST LR

LR

CIR

UL Committed Information Rate

eNodeB

SET LR LST LR

LR

CBS

Committed Burst Size

eNodeB

SET LR LST LR

LR

EBS

Excess Burst Size

eNodeB

SET LR LST LR

LR

SBT

Subboard Type

eNodeB

SET LR LST LR

LR

DLCIR

DL Committed Information Rate

eNodeB

SET LR LST LR

MPGRP

CN

Cabinet No.

eNodeB

ADD MPGRP DSP MPGRP RMV MPGRP RST MPGRP LST MPGRP ADD MPGRP DSP MPGRP RMV MPGRP RST MPGRP LST MPGRP ADD MPGRP DSP MPGRP RMV MPGRP RST MPGRP LST MPGRP ADD MPGRP DSP MPGRP RMV MPGRP RST MPGRP DSP DHCPRSLT LST MPGRP

MPGRP

SRN

Subrack No.

eNodeB

MPGRP

SN

Slot No.

eNodeB

MPGRP

MPGRPN

MLPPP Group No.

eNodeB

MPGRP

MCPPP

Multi-Class PPP

eNodeB

ADD MPGRP DSP MPGRP LST MPGRP

MPGRP

AUTH

Authentication Type eNodeB

ADD MPGRP LST MPGRP

MPGRP

UN

User Name

eNodeB

ADD MPGRP LST MPGRP

MPGRP

PWD

Password

eNodeB

ADD MPGRP LST MPGRP

MPGRP

LOCALIP

Local IP

eNodeB

ADD MPGRP DSP MPGRP LST MPGRP

MPGRP

IPMASK

Mask

eNodeB

ADD MPGRP DSP MPGRP LST MPGRP

MPGRP

PEERIP

Peer IP

eNodeB

ADD MPGRP DSP MPGRP LST MPGRP

MPGRP

MHO

MP/MC Header Option

eNodeB

ADD MPGRP LST MPGRP

MPGRP

MUXCP

PPPMUX

eNodeB

ADD MPGRP DSP MPGRP LST MPGRP

MPGRP

FRAGSIZE

MLPPP Fragment Size

eNodeB

ADD MPGRP LST MPGRP

MPGRP

MAXSFLEN

PPP Mux Subframe eNodeB Max Length

ADD MPGRP LST MPGRP

MPGRP

MAXMFLEN

PPP Muxframe Max eNodeB Length

ADD MPGRP LST MPGRP

MPGRP

MUXTIME

PPPMUX Combine eNodeB Timeout

ADD MPGRP LST MPGRP

MPGRP

MCCLASS

MCPPP Class

eNodeB

ADD MPGRP LST MPGRP

MPGRP

IPHC

IP Header Compression

eNodeB

ADD MPGRP DSP MPGRP LST MPGRP

MPGRP

MPDAAT

MLPPP Packets Discard Alarm Appear Threshold

eNodeB

ADD MPGRP LST MPGRP

MPGRP

MPDADT

MLPPP Packets Discard Alarm Disappear Threshold

eNodeB

ADD MPGRP LST MPGRP

MPGRP

MPGroupStatus

MLPPP Group Status

eNodeB

DSP MPGRP

MPGRP

IPCPSTATUS

IPCP Status

eNodeB

DSP MPGRP

MPGRP

PPPMUXSTATUS

PPPMUX Status

eNodeB

DSP MPGRP

MPGRP

LOCALIPNEGRLT

Local IP Negotiation eNodeB Result Local IP Mask Negotiation Result

DSP MPGRP

MPGRP

IPMASKNEGRLT

eNodeB

DSP MPGRP

MPGRP

PEERIPNEGRLT

Peer IP Negotiation eNodeB Result

DSP MPGRP

MPGRP

MCPPPNEGRLT

Multi-Class PPP Negotiation Result Maximum Receive Unit Negotiation Result PPPMUX Negotiation Result ACFC Negotiation Result

eNodeB

DSP MPGRP

MPGRP

MRUNEGRLT

eNodeB

DSP MPGRP

MPGRP

MUXNEGRLT

eNodeB

DSP MPGRP

MPGRP

ACFCNEGRLT

eNodeB

DSP MPGRP

MPGRP

PFCNEGRLT

PFC Negotiation Result IPHC Negotiation Result Number of RX Packets Number of TX Packets RX Flow TX Flow

eNodeB

DSP MPGRP

MPGRP

IPHCNEGRLT

eNodeB

DSP MPGRP

MPGRP

RXPKT

eNodeB

DSP MPGRP

MPGRP MPGRP MPGRP

TXPKT RXFLOW TXFLOW

eNodeB eNodeB eNodeB

DSP MPGRP DSP MPGRP DSP MPGRP

MPGRP

IPNum

Number of IPs

eNodeB

DSP MPGRP

MPGRP

IPList

IP Address List

eNodeB

DSP MPGRP

MPGRP

SBT

Subboard Type

eNodeB

ADD MPGRP DSP MPGRP RMV MPGRP RST MPGRP LST MPGRP

MPGRP

RXBYTE

Number of RX Bytes

eNodeB

DSP MPGRP

MPGRP

RXDROPPKT

Number of RX Drop eNodeB Packets Number of TX Bytes eNodeB

DSP MPGRP

MPGRP

TXBYTE

DSP MPGRP

MPGRP

TXDROPPKT

Number of TX Drop eNodeB Packets

DSP MPGRP

MPLNK

CN

Cabinet No.

eNodeB

ADD MPLNK DSP MPLNK RMV MPLNK LST MPLNK ADD MPLNK DSP MPLNK RMV MPLNK LST MPLNK ADD MPLNK DSP MPLNK RMV MPLNK LST MPLNK ADD MPLNK DSP MPLNK RMV MPLNK DSP DHCPRSLT LST MPLNK ADD MPLNK DSP MPLNK LST MPLNK

MPLNK

SRN

Subrack No.

eNodeB

MPLNK

SN

Slot No.

eNodeB

MPLNK

PPPLNKN

MLPPP Link No.

eNodeB

MPLNK

MPGRPN

MLPPP Group No.

eNodeB

MPLNK

E1T1SRN

E1/T1 Subrack No. eNodeB

ADD MPLNK LST MPLNK

MPLNK

E1T1SN

E1/T1 Slot No.

eNodeB

ADD MPLNK LST MPLNK

MPLNK

E1T1PN

E1/T1 Port No.

eNodeB

ADD MPLNK LST MPLNK

MPLNK

TSN

Timeslot No.

eNodeB

ADD MPLNK LST MPLNK

MPLNK

MRU

Maximum Receive Unit

eNodeB

ADD MPLNK DSP MPLNK LST MPLNK

MPLNK

PFC

Protocol Field Compression

eNodeB

ADD MPLNK DSP MPLNK LST MPLNK

MPLNK

ACFC

Address and Control Field Compression

eNodeB

ADD MPLNK DSP MPLNK LST MPLNK

MPLNK

RESTARTTMR

Negotiation Time

eNodeB

ADD MPLNK LST MPLNK

MPLNK

SBT

Subboard Type

eNodeB

ADD MPLNK DSP MPLNK RMV MPLNK LST MPLNK

MPLNK

MPGRPSBT

MLPPP Group Subboard Type

eNodeB

ADD MPLNK LST MPLNK

MPLNK

MPLNKSTATUS

MLPPP Link Status eNodeB

DSP MPLNK

MPLNK

LCPSTATUS

LCP Status

eNodeB

DSP MPLNK

MPLNK

MRUNEGRLT

Maximum Receive Unit Negotiation Result PFC Negotiation Result

eNodeB

DSP MPLNK

MPLNK

PFCNEGRLT

eNodeB

DSP MPLNK

MPLNK

ACFCNEGRLT

ACFC Negotiation Result

eNodeB

DSP MPLNK

MPLNK

E1T1SBT

E1/T1 Subboard Type

eNodeB

ADD MPLNK LST MPLNK

MPLNK

RXPKT

Number of RX Packets Number of RX Bytes

eNodeB

DSP MPLNK

MPLNK

RXBYTE

eNodeB

DSP MPLNK

MPLNK

RXDROPPKT

Number of RX Drop eNodeB Packets Number of TX Packets eNodeB

DSP MPLNK

MPLNK

TXPKT

DSP MPLNK

MPLNK

TXBYTE

Number of TX Bytes eNodeB

DSP MPLNK

MPLNK

TXDROPPKT

Number of TX Drop eNodeB Packets

DSP MPLNK ADD OMCH DSP OMCH MOD OMCH RMV OMCH LST OMCH

OMCH

FLAG

Master/Slave Flag

eNodeB

OMCH

IP

Local IP

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

MASK

Local Mask

eNodeB

ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH

OMCH

PEERIP

Peer IP

eNodeB

ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH

OMCH

PEERMASK

Peer Mask

eNodeB

ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH

OMCH

CN

Cabinet No.

eNodeB

ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH

OMCH

SRN

Subrack No.

eNodeB

ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH ADD OMCH MOD OMCH DSP DHCPRSLT

OMCH

SN

Slot No.

eNodeB

OMCH

BEAR

Bearer Type

eNodeB

OMCH

BRT

Binding Route

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

DSTIP

Destination IP

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

DSTMASK

Destination Mask

eNodeB

ADD OMCH MOD OMCH DSP DHCPRSLT DSP OMCH LST OMCH

OMCH

RT

Route Type

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

IFT

Interface Type

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

IFNO

Interface No.

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

PREF

Preference

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

NEXTHOP

Next Hop IP

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH

Status

OM Channel Status eNodeB

DSP OMCH

OMCH

UsedState

Used State

eNodeB

DSP OMCH

OMCH

SBT

Subboard Type

eNodeB

ADD OMCH MOD OMCH DSP OMCH LST OMCH

OMCH6

LOCALIP6

Local IPv6 Address eNodeB

ADD OMCH6 MOD OMCH6 DSP OMCH6 LST OMCH6

OMCH6

PEERIP6

Peer IPv6 Address

eNodeB

ADD OMCH6 MOD OMCH6 DSP OMCH6 LST OMCH6

OMCH6

Status

OM Channel Status eNodeB

DSP OMCH6

PACKETFILTER

CN

Cabinet No.

eNodeB

ADD PACKETFILTER DSP PACKETFILTER RMV PACKETFILTER LST PACKETFILTER ADD PACKETFILTER DSP PACKETFILTER RMV PACKETFILTER LST PACKETFILTER

PACKETFILTER

SRN

Subrack No.

eNodeB

PACKETFILTER

SN

Slot No.

eNodeB

ADD PACKETFILTER DSP PACKETFILTER RMV PACKETFILTER LST PACKETFILTER ADD PACKETFILTER DSP PACKETFILTER RMV PACKETFILTER LST PACKETFILTER

PACKETFILTER

PT

Port Type

eNodeB

PACKETFILTER

PN

Port No.

eNodeB

ADD PACKETFILTER DSP PACKETFILTER RMV PACKETFILTER LST PACKETFILTER

PACKETFILTER

ACLID

Advanced ACL ID

eNodeB

ADD PACKETFILTER DSP PACKETFILTER LST PACKETFILTER

PACKETFILTER

MB

Match Behavior

eNodeB

ADD PACKETFILTER DSP PACKETFILTER LST PACKETFILTER

PACKETFILTER

SBT

Subboard Type

eNodeB

ADD PACKETFILTER DSP PACKETFILTER RMV PACKETFILTER LST PACKETFILTER

PACKETFILTER

TxPackets

Number of TX Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

RxPackets

Number of RX Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

TxPermitPacket

Number of TX Permit Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

RxPermitPacket

Number of RX Permit Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

TxDenyPacket

Number of TX Deny eNodeB Packets

DSP PACKETFILTER

PACKETFILTER

RxDenyPacket

Number of RX Deny eNodeB Packets

DSP PACKETFILTER

PACKETFILTER

TxBytes

Bytes of TX Packets eNodeB

DSP PACKETFILTER

PACKETFILTER

RxBytes

Bytes of RX Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

TxPermitBytes

Bytes of TX Permit Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

RxPermitBytes

Bytes of RX Permit eNodeB Packets

DSP PACKETFILTER

PACKETFILTER

TxDenyBytes

Bytes of TX Deny Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

RxDenyBytes

Bytes of RX Deny Packets

eNodeB

DSP PACKETFILTER

PACKETFILTER

RxDefaultBytes

Bytes of RX Packets Matched Default Behavior

eNodeB

DSP PACKETFILTER

PACKETFILTER

RxDefaultPackets

Number of RX Packets Matched Default Behavior

eNodeB

DSP PACKETFILTER

PACKETFILTER

ACLID2

Layer 2 ACL ID

eNodeB

ADD PACKETFILTER DSP PACKETFILTER LST PACKETFILTER

PACKETFILTER

FM

Filter Mode

eNodeB

ADD PACKETFILTER DSP PACKETFILTER LST PACKETFILTER

PINGFILTER

IP

IP Address

eNodeB

ADD PINGFILTER RMV PINGFILTER LST PINGFILTER

PINGFILTER

MASK

Mask

eNodeB

ADD PINGFILTER RMV PINGFILTER LST PINGFILTER

PMTUCFG

MODE

Detection Mode

eNodeB

SET PMTUCFG LST PMTUCFG

PMTUCFG

UDPPORT

UDP Port No.

eNodeB

SET PMTUCFG LST PMTUCFG

PMTUCFG

DETECTPERIOD

Detection Period

eNodeB

SET PMTUCFG LST PMTUCFG

PMTUCFG

AGINGPERIOD

Aging Period

eNodeB

SET PMTUCFG LST PMTUCFG

PMTUCFG

DSCP

DSCP

eNodeB

SET PMTUCFG LST PMTUCFG

PORTSECURITY

CN

Cabinet No.

eNodeB

DSP PORTSECURITY SET PORTSECURITY LST PORTSECURITY DSP PORTSECURITY SET PORTSECURITY LST PORTSECURITY DSP PORTSECURITY SET PORTSECURITY LST PORTSECURITY

PORTSECURITY

SRN

Subrack No.

eNodeB

PORTSECURITY

SN

Slot No.

eNodeB

PORTSECURITY

SBT

Subboard Type

eNodeB

DSP PORTSECURITY SET PORTSECURITY LST PORTSECURITY

PORTSECURITY

PT

Port Type

eNodeB

DSP PORTSECURITY SET PORTSECURITY LST PORTSECURITY

PORTSECURITY

PN

Port No.

eNodeB

DSP PORTSECURITY SET PORTSECURITY LST PORTSECURITY

PORTSECURITY

SWITCH

Enable Flag

eNodeB

SET PORTSECURITY DSP PORTSECURITY LST PORTSECURITY

PPPLNK

CN

Cabinet No.

eNodeB

ADD PPPLNK DSP PPPLNK RMV PPPLNK RST PPPLNK LST PPPLNK

PPPLNK

SRN

Subrack No.

eNodeB

ADD PPPLNK DSP PPPLNK RMV PPPLNK RST PPPLNK LST PPPLNK ADD PPPLNK DSP PPPLNK RMV PPPLNK RST PPPLNK LST PPPLNK ADD PPPLNK DSP PPPLNK RMV PPPLNK RST PPPLNK DSP DHCPRSLT LST PPPLNK

PPPLNK

SN

Slot No.

eNodeB

PPPLNK

PPPLNKN

PPP Link No.

eNodeB

PPPLNK

PN

Port No.

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

AUTH

Authentication Type eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

UN

User Name

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

PWD

Password

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

TSN

Time Slot No.

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

LOCALIP

Local IP

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

IPMASK

Mask

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

PEERIP

Peer IP

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

MUXCP

PPPMUX

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

MAXSFLEN

Maximum Length of eNodeB PPP Mux Subframe

ADD PPPLNK LST PPPLNK

PPPLNK

MAXMFLEN

Maximum Length of eNodeB PPP Muxframe

ADD PPPLNK LST PPPLNK

PPPLNK

MUXTIME

PPP Muxframe Combination Timeout

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

IPHC

IP Header Compression

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

MRU

Maximum Receive Unit

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

PFC

Protocol Field Compression

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

ACFC

Address and Control Field Compression

eNodeB

ADD PPPLNK DSP PPPLNK LST PPPLNK

PPPLNK

RESTARTTMR

Negotiation Time

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

PPPLinkStatus

Link Status

eNodeB

DSP PPPLNK

PPPLNK

LCPSTATUS

LCP Status

eNodeB

DSP PPPLNK

PPPLNK

IPCPSTATUS

IPCP Status

eNodeB

DSP PPPLNK

PPPLNK

PPPMUXSTATUS

PPPMUX Status

eNodeB

DSP PPPLNK

PPPLNK

LOCALIPNEGRLT

Local IP Negotiation eNodeB Result

DSP PPPLNK

PPPLNK

MASKNEGRLT

Local IP Mask Negotiation Result

eNodeB

DSP PPPLNK

PPPLNK

PEERIPNEGRLT

Peer IP Negotiation eNodeB Result

DSP PPPLNK

PPPLNK

IPHCNEGRLT

IPHC Negotiation Result

eNodeB

DSP PPPLNK

PPPLNK

ACFCNEGRLT

ACFC Negotiation Result

eNodeB

DSP PPPLNK

PPPLNK

PFCNEGRLT

PFC Negotiation Result

eNodeB

DSP PPPLNK

PPPLNK

MRUNEGRLT

Maximum Receive Unit Negotiation Result

eNodeB

DSP PPPLNK

PPPLNK

MUXNEGRLT

PPPMUX Negotiation Result

eNodeB

DSP PPPLNK

PPPLNK

RXPKT

Number of RX Packets

eNodeB

DSP PPPLNK

PPPLNK

TXPKT

Number of TX Packets

eNodeB

DSP PPPLNK

PPPLNK

RXFLOW

RX Flow

eNodeB

DSP PPPLNK

PPPLNK

TXFLOW

TX Flow

eNodeB

DSP PPPLNK

PPPLNK

IPNum

Number of IPs

eNodeB

DSP PPPLNK

PPPLNK

IPList

IP Address List

eNodeB

DSP PPPLNK

PPPLNK

FFAPHOLD

PPP Fault Frame Occurrence Threshold

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

FFDPHOLD

PPP Fault Frame Clear Threshold

eNodeB

ADD PPPLNK LST PPPLNK

PPPLNK

SBT

Subboard Type

eNodeB

ADD PPPLNK DSP PPPLNK RMV PPPLNK RST PPPLNK LST PPPLNK

PPPLNK

RXBYTE

Number of RX Bytes

eNodeB

DSP PPPLNK

PPPLNK

RXDROPPKT

Number of RX Drop eNodeB Packets

DSP PPPLNK

PPPLNK

TXBYTE

Number of TX Bytes eNodeB

DSP PPPLNK

PPPLNK

TXDROPPKT

Number of TX Drop eNodeB Packets

DSP PPPLNK

PRI2QUE

PRI0

PriOfQue0

eNodeB

SET PRI2QUE LST PRI2QUE

PRI2QUE

PRI1

PriOfQue1

eNodeB

SET PRI2QUE LST PRI2QUE

PRI2QUE

PRI2

PriOfQue2

eNodeB

SET PRI2QUE LST PRI2QUE

PRI2QUE

PRI3

PriOfQue3

eNodeB

SET PRI2QUE LST PRI2QUE

PRI2QUE

PRI4

PriOfQue4

eNodeB

SET PRI2QUE LST PRI2QUE

PRI2QUE

PRI5

PriOfQue5

eNodeB

SET PRI2QUE LST PRI2QUE

PRI2QUE

PRI6

PriOfQue6

eNodeB

SET PRI2QUE LST PRI2QUE

RSCGRP

CN

Cabinet No.

eNodeB

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

SRN

Subrack No.

eNodeB

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

SN

Slot No.

eNodeB

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

BEAR

Transmission Resource Group Bear Type

eNodeB

RSCGRP

SBT

Subboard Type

eNodeB

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

PT

Bearing Port Type

eNodeB

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

PN

Bearing Port No.

eNodeB

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

RSCGRPID

Transmission eNodeB Resource Group ID

ADD RSCGRP DSP RSCGRP MOD RSCGRP RMV RSCGRP LST RSCGRP

RSCGRP

RU

Rate Unit

eNodeB

ADD RSCGRP MOD RSCGRP DSP RSCGRP LST RSCGRP

RSCGRP

TXBW

Tx Bandwidth

eNodeB

ADD RSCGRP MOD RSCGRP DSP RSCGRP LST RSCGRP

RSCGRP

RXBW

Rx Bandwidth

eNodeB

ADD RSCGRP MOD RSCGRP DSP RSCGRP LST RSCGRP

RSCGRP

TXCBS

TX Committed Burst eNodeB Size

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

TXEBS

TX Excessive Burst eNodeB Size

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

OID

Operator ID

eNodeB

ADD RSCGRP LST RSCGRP

RSCGRP

WEIGHT

Scheduling Weight eNodeB

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

TXCIR

TX Committed Information Rate

eNodeB

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

RXCIR

RX Committed Information Rate

eNodeB

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

TXPIR

TX Peak Information Rate

eNodeB

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

RXPIR

RX Peak Information Rate

eNodeB

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

TXPBS

TX Peak Burst Size eNodeB

ADD RSCGRP MOD RSCGRP LST RSCGRP

RSCGRP

TxRTBw

Realtime TX Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

RxRTBw

Realtime RX Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

TxNRTBw

Non-Realtime TX Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

RxNRTBw

Non-Realtime RX Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

TxNRTResvBw

Non-Realtime Reserved TX Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

RxNRTResvBw

Non-Realtime Reserved RX Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

TxGBRBwRlt

GBR Tx Bandwidth eNodeB

DSP RSCGRP

RSCGRP

RxGBRBwRlt

GBR Rx Bandwidth eNodeB

DSP RSCGRP

RSCGRP

RateCfgType

Rate Configuration Type

eNodeB

DSP RSCGRP

RSCGRP

ULAdminBw

UL Admission Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

DLAdminBw

DL Admission Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

ULCirAdminBw

UL CIR Admission Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

DLCirAdminBw

DL CIR Admission Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

ULPirAdminBw

UL PIR Admission Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

DLPirAdminBw

DL PIR Admission Bandwidth

eNodeB

DSP RSCGRP

RSCGRP

TxLgcPortFlow

Realtime Tx Traffic eNodeB

DSP RSCGRP

RSCGRPALG

CN

Cabinet No.

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

SRN

Subrack No.

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

SN

Slot No.

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

SBT

Subboard Type

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

PT

Bearing Port Type

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

PN

Bearing Port No.

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

RSCGRPID

Transmission eNodeB Resource Group ID

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

TXSSW

TX Traffic Shaping Switch

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

TXBWASW

TX Bandwidth Adjustment Switch

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

RXBWASW

RX Bandwidth Adjustment Switch

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

PLRDTH

Packet Loss Ratio Down Threshold

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

DDTH

Delay Variation Down Threshold

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

TXBWAMIN

TX Bandwidth Adjust Minimum

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

RXBWAMIN

RX Bandwidth Adjust Minimum

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

TCSW

Traffic Control Switch

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

OMTCSW

OM FTP Traffic Control Switch

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

PQN

PQ Number

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

CTTH

Congestion Time Threshold

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

CCTTH

Congestion Clear Time Threshold

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

TXRSVBW

TX Reserved Bandwidth

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

RXRSVBW

RX Reserved Bandwidth

eNodeB

SET RSCGRPALG LST RSCGRPALG

RSCGRPALG

DROPPKTNUM

Drop Packet Number Threshold

eNodeB

SET RSCGRPALG LST RSCGRPALG

SCTPLNK

SCTPNO

SCTP Link No.

eNodeB

ADD SCTPLNK BLK SCTPLNK DSP SCTPLNK LST SCTPLNK MOD SCTPLNK RMV SCTPLNK RST SCTPLNK UBL SCTPLNK ADD SCTPLNK DSP SCTPLNK LST SCTPLNK ADD SCTPLNK DSP SCTPLNK LST SCTPLNK ADD SCTPLNK DSP SCTPLNK LST SCTPLNK ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

CN

Cabinet No.

eNodeB

SCTPLNK

SRN

Subrack No.

eNodeB

SCTPLNK

SN

Slot No.

eNodeB

SCTPLNK

MAXSTREAM

Maximum Stream No.

eNodeB

SCTPLNK

LOCIP

First Local IP Address

eNodeB

ADD SCTPLNK MOD SCTPLNK DSP SCTPLNK LST SCTPLNK

SCTPLNK

SECLOCIP

Second Local IP Address

eNodeB

ADD SCTPLNK MOD SCTPLNK DSP SCTPLNK LST SCTPLNK

SCTPLNK

LOCPORT

Local SCTP Port No.

eNodeB

ADD SCTPLNK MOD SCTPLNK DSP SCTPLNK LST SCTPLNK

SCTPLNK

PEERIP

First Peer IP Address

eNodeB

ADD SCTPLNK MOD SCTPLNK DSP SCTPLNK LST SCTPLNK

SCTPLNK

SECPEERIP

Second Peer IP Address

eNodeB

ADD SCTPLNK MOD SCTPLNK DSP SCTPLNK LST SCTPLNK

SCTPLNK

PEERPORT

Peer SCTP Port No.

eNodeB

ADD SCTPLNK MOD SCTPLNK DSP SCTPLNK LST SCTPLNK

SCTPLNK

RTOMIN

RTO Min Value

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

RTOMAX

RTO Max Value

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

RTOINIT

RTO Initial Value

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

RTOALPHA

RTO Alpha Value

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

RTOBETA

RTO Beta Value

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

HBINTER

Heart-beat Interval

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

MAXASSOCRETR

Max Association Retransmission

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

MAXPATHRETR

Max Path Retransmission

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

CHKSUMTX

Send Message Checksum Flag

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

CHKSUMRX

Receive Message Checksum Flag

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

CHKSUMTYPE

Checksum Arithmetic Type

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

AUTOSWITCH

Switch Back Flag

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

SWITCHBACKHBN Heart-beat Times UM When Switch Back

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

AssocState

SCTP Link Status

eNodeB

DSP SCTPLNK

SCTPLNK

TransferCause

Status Change Cause

eNodeB

DSP SCTPLNK

SCTPLNK

TransferTime

Status Change Time

eNodeB

DSP SCTPLNK

SCTPLNK

OUTSTREAM

Out Stream Number eNodeB

DSP SCTPLNK

SCTPLNK

INSTREAM

In Stream Number

eNodeB

DSP SCTPLNK

SCTPLNK

WORKADDRFLAG Work Address Flag eNodeB

DSP SCTPLNK

SCTPLNK

BLKFLAG

Block Flag

eNodeB

DSP SCTPLNK LST SCTPLNK

SCTPLNK

TSACK

SACK Timeout

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK

SCTPLNK

DESCRI

Description Info

eNodeB

ADD SCTPLNK MOD SCTPLNK LST SCTPLNK ADD SCTPLNK6 BLK SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6 MOD SCTPLNK6 RMV SCTPLNK6 RST SCTPLNK6 UBL SCTPLNK6 ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

SCTPNO

IPv6 SCTP Link No. eNodeB

SCTPLNK6

MAXSTREAM

Maximum Stream No.

eNodeB

SCTPLNK6

LOCIP

First Local IPv6 Address

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6

SCTPLNK6

SECLOCIP

Second Local IPv6 Address

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6

SCTPLNK6

LOCPORT

Local IPv6 SCTP Port No.

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6

SCTPLNK6

PEERIP

First Peer IPv6 Address

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6

SCTPLNK6

SECPEERIP

Second Peer IPv6 Address

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6

SCTPLNK6

PEERPORT

Peer IPv6 SCTP Port No.

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 DSP SCTPLNK6 LST SCTPLNK6

SCTPLNK6

RTOMIN

RTO Min Value

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

RTOMAX

RTO Max Value

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

RTOINIT

RTO Initial Value

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

RTOALPHA

RTO Alpha Value

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

RTOBETA

RTO Beta Value

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

HBINTER

Heart-beat Interval

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

MAXASSOCRETR

Max Association Retransmission

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

MAXPATHRETR

Max Path Retransmission

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

CHKSUMTYPE

Checksum Algorithm Type

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

SWITCHBACKFLA Switch Back Flag G

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

SWITCHBACKHBN Heart-beat Times UM When Switch Back

eNodeB

ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6

SCTPLNK6

AssocState

IPv6 SCTP Link Status

eNodeB

DSP SCTPLNK6

SCTPLNK6

TransferCause

Status Change Cause

eNodeB

DSP SCTPLNK6

SCTPLNK6

TransferTime

Status Change Time

eNodeB

DSP SCTPLNK6

SCTPLNK6

OUTSTREAM

Out Stream Number eNodeB

DSP SCTPLNK6

SCTPLNK6

INSTREAM

In Stream Number

eNodeB

DSP SCTPLNK6

SCTPLNK6

WORKADDRFLAG Work Address Flag eNodeB

DSP SCTPLNK6

SCTPLNK6

BLKFLAG

Block Flag

eNodeB

DSP SCTPLNK6 LST SCTPLNK6 ADD SCTPLNK6 MOD SCTPLNK6 LST SCTPLNK6 ADD SUBNETVLAN LST SUBNETVLAN MOD SUBNETVLAN RMV SUBNETVLAN ADD SUBNETVLAN LST SUBNETVLAN MOD SUBNETVLAN RMV SUBNETVLAN ADD SUBNETVLAN MOD SUBNETVLAN LST SUBNETVLAN

SCTPLNK6

DESCRI

Description Info

eNodeB

SUBNETVLAN

IP

IP Address

eNodeB

SUBNETVLAN

MASK

Mask

eNodeB

SUBNETVLAN

VLANID

VLAN ID

eNodeB

TACALG

RSCGRPULCACS WITCH

Resource Group Uplink Admission Control Algorithm Switch

eNodeB

SET TACALG LST TACALG

TACALG

RSCGRPDLCACS WITCH

Resource Group Downlink Admission eNodeB Control Algorithm Switch

SET TACALG LST TACALG

TACALG

USERDATATYPE1 User Data Type 1 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE2 User Data Type 2 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE3 User Data Type 3 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE4 User Data Type 4 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE5 User Data Type 5 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE6 User Data Type 6 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE7 User Data Type 7 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE8 User Data Type 8 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

USERDATATYPE9 User Data Type 9 ACTFACTOR Act Factor

eNodeB

SET TACALG LST TACALG

TACALG

Uplink Handover TRMULHOCACTH Service Admission Threshold

eNodeB

SET TACALG LST TACALG

TACALG

Downlink Handover TRMDLHOCACTH Service Admission eNodeB Threshold

SET TACALG LST TACALG

TACALG

Uplink Golden New TRMULGOLDCAC Service Admission eNodeB TH Threshold

SET TACALG LST TACALG

TACALG

Downlink Golden TRMDLGOLDCAC New Service TH Admission Threshold

eNodeB

SET TACALG LST TACALG

TACALG

Uplink Silver New TRMULSILVERCA Service Admission CTH Threshold

eNodeB

SET TACALG LST TACALG

TACALG

Downlink Silver TRMDLSILVERCA New Service CTH Admission Threshold

eNodeB

SET TACALG LST TACALG

TACALG

TRMULBRONZEC ACTH

Uplink Bronze New Service Admission eNodeB Threshold

SET TACALG LST TACALG

TACALG

TRMDLBRONZEC ACTH

Downlink Bronze New Service Admission Threshold

eNodeB

SET TACALG LST TACALG

TACALG

TRMULGBRCACT H

Uplink GBR Service Admission eNodeB Threshold

SET TACALG LST TACALG

TACALG

TRMDLGBRCACT H

Downlink GBR Service Admission Threshold

eNodeB

SET TACALG LST TACALG

TACALG

TRMULPRESW

Uplink Pre-emption eNodeB Algorithm Switch

SET TACALG LST TACALG

TACALG

TRMDLPRESW

Downlink Preemption Algorithm Switch

eNodeB

SET TACALG LST TACALG

TACALG

PORTULOBSW

Physical Port Up Link OverBooking Switch

eNodeB

SET TACALG LST TACALG

TACALG

PORTDLOBSW

Physical Port Down Link OverBooking eNodeB Switch

SET TACALG LST TACALG

TACALG

PORTULCACSW

Physical Port Up Link Admission Switch

eNodeB

SET TACALG LST TACALG

TACALG

PORTDLCACSW

Physical Port Down Link Admission eNodeB Switch

SET TACALG LST TACALG

TLDRALG

TRMULLDRTRGTH

Uplink High Load Trigger Threshold

eNodeB

SET TLDRALG LST TLDRALG

TLDRALG

TRMDLLDRTRGTH

Downlink High Load eNodeB Trigger Threshold

SET TLDRALG LST TLDRALG

TLDRALG

TRMULLDRCLRTH

Uplink High Load Clear Threshold

eNodeB

SET TLDRALG LST TLDRALG

TLDRALG

TRMDLLDRCLRTH

Downlink High Load eNodeB Clear Threshold

SET TLDRALG LST TLDRALG

TLDRALG

TRMULMLDTRGT H

Uplink Medium Load Trigger Threshold

eNodeB

SET TLDRALG LST TLDRALG

TLDRALG

TRMDLMLDTRGT H

Downlink Medium Load Trigger Threshold

eNodeB

SET TLDRALG LST TLDRALG

TLDRALG

Uplink Medium TRMULMLDCLRTH Load Clear Threshold

eNodeB

SET TLDRALG LST TLDRALG

TLDRALG

Downlink Medium TRMDLMLDCLRTH Load Clear Threshold

eNodeB

SET TLDRALG LST TLDRALG

TLFRSWITCH

TLFRSWITCH

Transmission Link Fault Recover Switch

eNodeB

SET TLFRSWITCH LST TLFRSWITCH

TOLCALG

TRMULOLCSWITC Uplink OLC H Algorithm Switch

eNodeB

SET TOLCALG LST TOLCALG

TOLCALG

TRMDLOLCSWITC Downlink OLC H Algorithm Switch

eNodeB

SET TOLCALG LST TOLCALG

TOLCALG

TRMULOLCTRIGT Uplink OLC Trigger eNodeB H Threshold

SET TOLCALG LST TOLCALG

TOLCALG

TRMULOLCRELTH

Uplink OLC eNodeB Release Threshold

SET TOLCALG LST TOLCALG

TOLCALG

TRMOLCRELBEAR OLC Release ERNUM Bearer No.

eNodeB

SET TOLCALG LST TOLCALG

TOLCALG

TRMDLOLCTRIGT Downlink OLC H Trigger Threshold

eNodeB

SET TOLCALG LST TOLCALG

TOLCALG

TRMDLOLCRELTH

Downlink OLC eNodeB Release Threshold

SET TOLCALG LST TOLCALG

TRANSPORT

MODE

Ping Filter Mode

eNodeB

SET PINGFILTERMODE LST PINGFILTERMODE

TRANSPORT

BatchFailPkt

Number of Packets Discarded Due to eNodeB Fragmentation Failures Total Number of Encrypted Packets Received at the IP Layer of the Receiver

DSP IPSTAT

TRANSPORT

InEncryptedPkt

eNodeB

DSP IPSTAT

TRANSPORT

Number of Packets Successfully InDecryptSucceedP Decrypted at the IP eNodeB kt Layer of the Receiver Total Number of Packets Failed in InEspDecryptFailPk ESP Decryption at eNodeB t the IP Layer of the Receiver Hardware

DSP IPSTAT

TRANSPORT

DSP IPSTAT

TRANSPORT

InAhAuthFailPkt

Total Number of Packets Failed in AH Authentication at the IP Layer of the Receiver Hardware

eNodeB

DSP IPSTAT

TRANSPORT

Total Number of Packets Discarded InShouldNotEncrypt at the IP Layer of eNodeB edPkt the Receiver Due to Having Been Encrypted Total Number of Packets Received by the Decryption Module of the Receiver

DSP IPSTAT

TRANSPORT

InTotalPkt

eNodeB

DSP IPSTAT

TRANSPORT

InDecryptFailPkt

Number of Failing Decrypted Packets eNodeB at the Receiver Total Number of IKE Packets Received at the IP Layer of the Receiver

DSP IPSTAT

TRANSPORT

InIkePkt

eNodeB

DSP IPSTAT

TRANSPORT

Total Number of Packets Discarded InWrongSIPEncrypt at the IP Layer of eNodeB edPkt the Receiver Due to Invalid Source IP Addresses Total Number of Packets Discarded InAntiReplayDropPk at the IP Layer of eNodeB t the Receiver Due to Replay Attacks Total Number of Packets Discarded at the IP Layer of eNodeB the Receiver Due to No Inbound SA

DSP IPSTAT

TRANSPORT

DSP IPSTAT

TRANSPORT

InSaMissDropPkt

DSP IPSTAT

TRANSPORT

Total Number of Packets Discarded InUnsupportAhAlgD at the IP Layer of eNodeB ropPkt the Receiver Due to Unsupported AH Algorithm

DSP IPSTAT

TRANSPORT

Total Number of Packets Discarded InUnsupportEspAlg at the IP Layer of eNodeB DropPkt the Receiver Due to Unsupported ESP Algorithm Total Number of Plain Packets Received at the IP Layer of the Receiver

DSP IPSTAT

TRANSPORT

InUnEncryptedPkt

eNodeB

DSP IPSTAT

TRANSPORT

Number of Packets Discarded at the IP InShouldEncrypted Layer of the eNodeB Pkt Receiver Due to not Being Encrypted

DSP IPSTAT

TRANSPORT

Number of Packets Successfully OutEncryptSucceed Encrypted at the IP eNodeB Pkt Layer of the Transmitter Total Number of Packets Failed to Be Encrypted at the eNodeB IP Layer of the Transmitter Total Number of Packets Received by the Encryption Module of the Transmitter

DSP IPSTAT

TRANSPORT

OutEncryptFailPkt

DSP IPSTAT

TRANSPORT

OutTotalPkt

eNodeB

DSP IPSTAT

TRANSPORT

Number of Packets That Should be OutNeedEncryptPkt eNodeB Encrypted at the Transmitter Total Number of Packets Discarded OutSaMissDropPkt at the IP Layer of eNodeB the Transmitter due to No Outbound SA Total Number of Packets Discarded OutUnsupportAhAlg at the IP Layer of eNodeB DropPkt the Transmitter Due to Unsupported AH Algorithm

DSP IPSTAT

TRANSPORT

DSP IPSTAT

TRANSPORT

DSP IPSTAT

TRANSPORT

Total Number of Packets Discarded OutUnsupportEspAl at the IP Layer of eNodeB gDropPkt the Transmitter Due to Unsupported ESP Algorithm Total Number of Packets Failed in AH Authentication at the IP Layer of the Transmitter Hardware Total Number of Packets Failed in ESP Encryption at the IP Layer of the Transmitter

DSP IPSTAT

TRANSPORT

OutAhAuthFailPkt

eNodeB

DSP IPSTAT

TRANSPORT

OutEspDecryptFail Pkt

eNodeB

DSP IPSTAT

TRANSPORT

Total Number of Packets Discarded OutSeqOverflowDro at the IP Layer of eNodeB pPkt the Transmitter Due to SN Overflow Total Number of Packets That OutNoNeedEncrypt Should Not Have Pkt Been Encrypted at the IP Layer of the Transmitter

DSP IPSTAT

TRANSPORT

eNodeB

DSP IPSTAT

TRANSPORT

OutIkePkt

Total Number of IKE Packets Sent at eNodeB the IP Layer of the Transmitter

DSP IPSTAT

TUNNEL

SCN

Source Cabinet No. eNodeB

ADD TUNNEL DSP TUNNEL MOD TUNNEL RMV TUNNEL LST TUNNEL ADD TUNNEL DSP TUNNEL MOD TUNNEL RMV TUNNEL LST TUNNEL ADD TUNNEL DSP TUNNEL MOD TUNNEL RMV TUNNEL LST TUNNEL

TUNNEL

SSRN

Source Subrack No. eNodeB

TUNNEL

SSN

Source Slot No.

eNodeB

TUNNEL

TUNNELID

Tunnel No.

eNodeB

ADD TUNNEL DSP TUNNEL MOD TUNNEL RMV TUNNEL LST TUNNEL

TUNNEL

DCN

Destination Cabinet eNodeB No.

ADD TUNNEL MOD TUNNEL DSP TUNNEL LST TUNNEL

TUNNEL

DSRN

Destination Subrack eNodeB No.

ADD TUNNEL MOD TUNNEL DSP TUNNEL LST TUNNEL

TUNNEL

DSN

Destination Slot No. eNodeB

ADD TUNNEL MOD TUNNEL DSP TUNNEL LST TUNNEL

TUNNEL

RcvByte

Number of RX Bytes

eNodeB

DSP TUNNEL

TUNNEL

RcvPacket

Number of RX Packets

eNodeB

DSP TUNNEL

TUNNEL

SendByte

Number of TX Bytes eNodeB

DSP TUNNEL

TUNNEL

SendPacket

Number of TX Packets

eNodeB

DSP TUNNEL

VLANCLASS

VLANGROUPNO

VLAN Group No.

eNodeB

ADD VLANCLASS LST VLANCLASS MOD VLANCLASS RMV VLANCLASS

VLANCLASS

TRAFFIC

Traffic Type

eNodeB

ADD VLANCLASS MOD VLANCLASS RMV VLANCLASS LST VLANCLASS

VLANCLASS

SRVPRIO

User Data Service Priority

eNodeB

ADD VLANCLASS MOD VLANCLASS RMV VLANCLASS LST VLANCLASS

VLANCLASS

VLANID

VLAN ID

eNodeB

ADD VLANCLASS MOD VLANCLASS LST VLANCLASS

VLANCLASS

VLANPRIO

VLAN Priority

eNodeB

ADD VLANCLASS MOD VLANCLASS LST VLANCLASS

VLANMAP

NEXTHOPIP

Next Hop IP

eNodeB

ADD VLANMAP MOD VLANMAP RMV VLANMAP LST VLANMAP

VLANMAP

MASK

Mask

eNodeB

ADD VLANMAP MOD VLANMAP RMV VLANMAP LST VLANMAP

VLANMAP

VLANMODE

VLAN Mode

eNodeB

ADD VLANMAP MOD VLANMAP LST VLANMAP

VLANMAP

VLANID

VLAN ID

eNodeB

ADD VLANMAP MOD VLANMAP LST VLANMAP

VLANMAP

VLANPRIO

VLAN Priority

eNodeB

ADD VLANMAP MOD VLANMAP LST VLANMAP

VLANMAP

VLANGROUPNO

VLAN Group No.

eNodeB

ADD VLANMAP MOD VLANMAP LST VLANMAP

VLANMAP

SETPRIO

Set VLAN Priority

eNodeB

ADD VLANMAP MOD VLANMAP LST VLANMAP

GTPU

TIMEOUTTH

ECHO Frame Timeout

eNodeB

MOD GTPU LST GTPU

GTPU

TIMEOUTCNT

ECHO Frame Timeout Count

eNodeB

MOD GTPU LST GTPU

GTPU

DSCP

DSCP

eNodeB

MOD GTPU LST GTPU

GTPU

STATICCHK

Static Check Switch eNodeB

MOD GTPU LST GTPU

Meaning

IsKey

Mandatory

Dynamic Attribute

Feature ID

Indicates the device number of the BF YES antenna. Indicates the cabinet number of NO the RRU connecting to the BF antenna. Indicates the subrack number of NO the RRU connecting to the BF antenna. Indicates the slot number of the RRU NO connecting to the BF antenna. Indicates the model NO of the BF antenna. Indicates the configured tilt of the NO BF antenna. Indicates the beamwidth formed NO after beamforming. Indicates the frequency band in which the BF antenna operates.

YES

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

YES

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the type of NO the BF antenna. Indicates the polarization mode of NO the BF antenna. Indicates the beamwidth of the NO antenna element. Indicates the number of physical antenna ports to which the BF antenna is connected.

NO

No

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

NO

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the amplitude offset at physical antenna port 1 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the phase offset at physical antenna port 1 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the amplitude offset at physical antenna port 2 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the phase offset at physical antenna port 2 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the amplitude offset at physical antenna port 3 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports.

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the phase offset at physical antenna port 3 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the amplitude offset at physical antenna port 4 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the phase offset at physical antenna port 4 when the BF antenna is used and NO cell-specific reference signals are transmitted from two ports. Indicates the amplitude offset at physical antenna port 1 when the BF antenna is used and NO cell-specific reference signals are transmitted from four ports. Indicates the phase offset at physical antenna port 1 when the BF antenna is used and NO cell-specific reference signals are transmitted from four ports.

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the amplitude offset at physical antenna port 2 when the BF antenna is used and NO cell-specific reference signals are transmitted from four ports. Indicates the phase offset at physical antenna port 2 when the BF antenna is used and NO cell-specific reference signals are transmitted from four ports.

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the ID of the eNodeB, which uniquely identifies an eNodeB within a PLMN(Public Land NO Mobile Network). This parameter is a part of the CGI(Cell Global Identifier).

NO

No

None

Indicates the name of the eNodeB, which uniquely NO identifies an eNodeB within a PLMN.

NO

No

None

Indicates the eNodeB type.

NO

NO

No

None

Indicates the switch for automatically powering on or off the eNodeB. If the switch is turned on, the RF channels of the RRUs/RFUs are shut down. In this situation, the RRUs/RFUs work in NO low power consumption mode. The RRUs/RFUs are reset after the eNodeB is powered on automatically. Then, the RRUs/RFUs start to carry services.

NO

No

LOFD-001025

Indicates the automatic power-off NO time of the eNodeB.

NO

No

LOFD-001025

Indicates the automatic power-on NO time of the eNodeB.

NO

No

LOFD-001025

Indicates the longitude of the eNodeB. A negative value indicates a NO west longitude, and a positive value indicates an east longitude. Indicates the latitude of the eNodeB. A negative value indicates a NO south latitude, and a positive value indicates a north latitude.

NO

No

None

NO

No

None

Indicates the ESN of the eNodeB NO backplane. This parameter indicates the license status of an eNodeB, which can be default, normal, demo, protected, or emergency. An operating eNodeB enters the default license state if either of the following conditions is true:1. No valid LKF is installed on the eNodeB. 2. The eNodeB has been in the protected NO license state for 60 days. In the default license state, the eNodeB operates at the default values of license control items. An operating eNodeB enters the normal license state when a commercial or Permanent & temporary LKF is installed on the eNodeB. In the normal license state, the eNodeB Indicates whether the eNodeB is automatically powered off. If this parameter is Poweroff, all RRUs/RFUs in the eNodeB enter the NO low power consumption mode, and all cells are unavailable. If this parameter is Normal, the eNodeB runs normally.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the position of the eNodeB.

NO

NO

No

None

Indicates the format of geographical NO coordinates.

NO

No

None

Indicates the latitude of the eNodeB in the NO WGS-84 coordinate system.

NO

No

None

Indicates the longitude of the eNodeB in the NO WGS-84 coordinate system.

NO

No

None

Indicates the communication protocol type used between the BBU and radio frequency (RF) units. The value CPRI indicates the Huawei proprietary NO protocol, and the value TDL_IR indicates the IR communication protocol defined by China Mobile Communication Corporation (CMCC).

NO

No

None

Indicates the type of YES a KPI alarm.

YES

No

None

Indicates whether to report the KPI NO alarm.

YES

No

None

Indicates the threshold for generating a KPI alarm. The thresholds for delay and variation on the transport network are expressed in units of ms. The thresholds for NO packet loss rates on the transport network or on NE ports are expressed in units of permillage. Other alarm thresholds are expressed in units of percentage.

YES

No

None

Indicates the threshold for clearing a KPI alarm. The thresholds for delay and variation on the transport network are expressed in units of ms. The thresholds for NO packet loss rates on the transport network or on NE ports are expressed in units of permillage. Other alarm thresholds are expressed in units of percentage.

YES

No

None

Indicates the minimum number of KPI checks. If the number of actual checks is less than NO the value of this parameter, KPI alarms are not reported or cleared.

NO

No

None

Indicates the duration for monitoring KPI alarms. The monitoring period is used in one of the following ways: 1. If the monitoring period is set to 15 minutes, 30 minutes, or 60 minutes, the configured start time for monitoring KPI alarms is invalid. For example, if a NO command for a KPI alarm monitoring is started between 8:00 and 8:05 (excluding 8:05) and the monitoring period is 15 minutes, the KPIs generated between 8:00 and 8:15 (excluding 8:15) are monitored. 2. If the monitoring period is set to one day, the configured start time for monitoring KPI alarms is valid. Indicates the start time for monitoring KPI alarms. This parameter is valid only when the NO monitoring period is one day. The start time must be on a full hour. Indicates the number of detection NO periods.

NO

No

None

NO

No

None

NO

No

None

Indicates the sector YES number.

YES

No

None

Indicates the longitude of the sector. A negative value indicates a NO west longitude, and a positive value indicates an east longitude. Indicates the latitude of the sector. A negative value indicates a NO south latitude, and a positive value indicates a north latitude. Indicates the antenna mode of the sector.

YES

No

None

YES

No

None

NO

YES

No

None

Indicates the multiple-input multiple-output (MIMO) mode of the NO sector, which can be normal MIMO or mutual-aid MIMO.

NO

No

LOFD-001038

Indicates the combination mode of the sector.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 1 is located.

YES

No

None

Indicates the subrack number of the RRU where the NO antenna port 1 is located. Indicates the slot number of the RRU NO where the antenna port 1 is located.

YES

No

None

YES

No

None

Indicates the port number of the antenna port 1.

NO

YES

No

None

Indicates the cabinet number of the RRU where the NO antenna port 2 is located. Indicates the subrack number of the RRU where the NO antenna port 2 is located. Indicates the slot number of the RRU NO where the antenna port 2 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 2.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 3 is located.

NO

No

None

Indicates the subrack number of the RRU where the NO antenna port 3 is located. Indicates the slot number of the RRU NO where the antenna port 3 is located.

NO

No

None

NO

No

None

Indicates the port number of the antenna port 3.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 4 is located. Indicates the subrack number of the RRU where the NO antenna port 4 is located. Indicates the slot number of the RRU NO where the antenna port 4 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 4.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 5 is located.

NO

No

None

Indicates the subrack number of the RRU where the NO antenna port 5 is located. Indicates the slot number of the RRU NO where the antenna port 5 is located.

NO

No

None

NO

No

None

Indicates the port number of the antenna port 5.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 6 is located. Indicates the subrack number of the RRU where the NO antenna port 6 is located. Indicates the slot number of the RRU NO where the antenna port 6 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 6.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 7 is located.

NO

No

None

Indicates the subrack number of the RRU where the NO antenna port 7 is located. Indicates the slot number of the RRU NO where the antenna port 7 is located.

NO

No

None

NO

No

None

Indicates the port number of the antenna port 7.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 8 is located. Indicates the subrack number of the RRU where the NO antenna port 8 is located. Indicates the slot number of the RRU NO where the antenna port 8 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 8.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 9 is located.

NO

No

None

Indicates the subrack number of the RRU where the NO antenna port 9 is located. Indicates the slot number of the RRU NO where the antenna port 9 is located.

NO

No

None

NO

No

None

Indicates the port number of the antenna port 9.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 10 is located. Indicates the subrack number of the RRU where the NO antenna port 10 is located. Indicates the slot number of the RRU NO where the antenna port 10 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 10.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 11 is located.

NO

No

None

Indicates the subrack number of the RRU where the NO antenna port 11 is located. Indicates the slot number of the RRU NO where the antenna port 11 is located.

NO

No

None

NO

No

None

Indicates the port number of the antenna port 11.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 12 is located. Indicates the subrack number of the RRU where the NO antenna port 12 is located. Indicates the slot number of the RRU NO where the antenna port 12 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 12.

NO

NO

No

None

Indicates the sector name, which is a NO string of a maximum of 30 characters.

NO

No

None

Indicates the altitude of the sector in the WGS-84 coordinate system. If the value is greater than 0, the sector is above the ellipsoid surface in the WGS-84 coordinate system. NO If the value is less than 0, the sector is below the ellipsoid surface in the WGS84 coordinate system. For details, see 3GPP TS 23.032 and 3GPP TS 36.455. Indicates the semimajor axis length of the uncertainty area by which the geographical location of the antennas in the sector is to be included. The NO smaller the parameter value is, the higher the positioning accuracy is. For details about the uncertainty area, see 3GPP TS 23.032.

YES

No

None

NO

No

None

Indicates the semiminor axis length of the uncertainty area by which the geographical location of the antennas in the sector is to be included. The NO smaller the parameter value is, the higher the positioning accuracy is. For details about the uncertainty area, see 3GPP TS 23.032. Indicates the major axis orientation of an uncertainty area by which the geographical location of the antennas in the sector is to be included. (The orientation is the counter-clockwise angle in degrees NO between the major axis and north). The smaller the parameter value is, the higher the positioning accuracy is. For details about the uncertainty area, see 3GPP TS 23.032.

NO

No

None

NO

No

None

Indicates the altitude of an uncertainty area by which the geographical location of the antennas in the sector is to be included. The altitude is in the NO WGS-84 coordinate system. The smaller the parameter value is, the higher the positioning accuracy is. For details about the uncertainty area, see 3GPP TS 23.032. Indicates the confidence level of an uncertainty area by which the geographical location of the antennas in the sector is to be included. The NO smaller the parameter value is, the higher the positioning accuracy is. For details about the uncertainty area, see 3GPP TS 23.032. Indicates the format of geographical NO coordinates. Indicates the latitude of the sector NO in the WGS-84 coordinate system. Indicates the longitude of the sector in the WGS- NO 84 coordinate system.

NO

No

None

NO

No

None

NO

No

None

NO

No

None

NO

No

None

Indicates the flag of the omnidirectional cell. If this parameter is set to TRUE, the cell is an NO omnidirectional cell. If this parameter is set to FALSE, the cell is not an omnidirectional cell. Indicates the cabinet number of the RRU where the NO antenna port 13 is located. Indicates the subrack number of the RRU where the NO antenna port 13 is located. Indicates the slot number of the RRU NO where the antenna port 13 is located.

NO

No

None

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 13.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 14 is located. Indicates the subrack number of the RRU where the NO antenna port 14 is located. Indicates the slot number of the RRU NO where the antenna port 14 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 14.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 15 is located. Indicates the subrack number of the RRU where the NO antenna port 15 is located. Indicates the slot number of the RRU NO where the antenna port 15 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 15.

NO

NO

No

None

Indicates the cabinet number of the RRU where the NO antenna port 16 is located. Indicates the subrack number of the RRU where the NO antenna port 16 is located. Indicates the slot number of the RRU NO where the antenna port 16 is located.

NO

No

None

NO

No

None

NO

No

None

Indicates the port number of the antenna port 16.

NO

NO

No

None

Indicates the maximum output power that can be configured for each TX channel of the sector. This parameter is specified based on the capabilities of all NO TX channels configured for the sector. It is set to the minimum value among the maximum output power of all TX channels. Indicates whether a license is granted to the sector. A license NO is required only by a dual-mode sector.

NO

Yes

None

NO

Yes

None

Indicates the range of RX channel frequencies supported by the sector. This parameter is set to the frequency band between the minimum and maximum frequencies on the RX channels of the RRU where the antenna ports are located. If a sector is configured on NO multiple RRUs, the frequency band supported by the sector is the intersection of frequency bands supported by the RRUs. If a sector is configured on a single RRU, the frequency band of the sector is the frequency band supported by the RRU.

NO

Yes

None

Indicates the range of TX channel frequencies supported by the sector. This parameter is set to the frequency band between the minimum and maximum frequencies on the TX channels of the RRU where the antenna ports are located. If a sector is configured on NO multiple RRUs, the frequency band supported by the sector is the intersection of frequency bands supported by the RRUs. If a sector is configured on a single RRU, the frequency band of the sector is the frequency band supported by the RRU.

NO

Yes

None

Indicates the policy for logging in to the Web LMT. The value COMPATIBLE indicates that if http is entered on the IE, the policy for logging in to the WebLMT is http, and if https is entered on the IE, the policy for logging in to the WebLMT is https. The value HTTPS_ONLY NO indicates that whether http or https is entered on the IE, the policy for logging in to the WebLMT is https. The value LOGIN_HTTPS_O NLY indicates that whether http or https is entered on the IE, the policy for logging in to the WebLMT is https, and then the policy turns to http after the logging. Indicates the device number of the ALD. The device number YES of the ALD must be unique. Indicates the vendor code of the device NO in the scanning result. Indicates the serial number of the device in the scanning result. NO

NO

No

LOFD-001024 / TDLOFD-001024

YES

No

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the device name of the ALD, which identifies the ALD. The format of the name is as follows: site_sector_device type_network type. The meanings of the parts are as follows: Site: indicates the number of the BS site. It is uniformly assigned during the network planning. Sector: indicates NO the number of the sector. It is unique within a site. Device type: indicates the type of currently connected device. It can be SINGLE_RET (Single-antenna Remote Electrical Tilt Unit), MULTI_RET (Multiantenna Remote Electrical Tilt Unit), TMA (Towermounted Amplifier). Network type: Indicates the cabinet number of the RRU or RFU NO that controls the ALD.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the subrack number of the RRU or RFU that controls the ALD.

NO

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU NO or RFU that controls the ALD.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the actual protocol version of NO the ALD. Indicates the total number of ALD subunits. NO

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the vendor NO code.

NO

No

None

Indicates the serial number of the ALD. The vendor code NO and the serial number uniquely identify an ALD. Indicates the version information NO about the ALD hardware. Indicates the version information NO about the ALD software. Indicates the device NO model of the ALD.

NO

No

None

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the device NO type of the ALD.

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the port number of the RRU or RFU that controls the ALD. It will be NO NULL if the RRU/RFU does not support to report this parameter.

NO

Yes

None

Indicates the cabinet number of the RRU or RFU where the antenna port is located.

YES

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the subrack number of the RRU or RFU where the antenna port is located.

YES

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU or RFU where the YES antenna port is located.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the number of the YES antenna port on the RRU or RFU.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the length of the feeder at the NO antenna port. Indicates the DL delay of the TMA. It should be specified according to the specification NO provided by the manufacturer. Typically, this parameter is smaller than 30 ns. Indicates the UL delay of the TMA. It should be specified according to the specification NO provided by the manufacturer. Typically, this parameter is smaller than 30 ns.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the state of the ALD power supply switch. The ALD power supply switches for the SINGLE_RET (Single-antenna Remote Electrical Tilt), MULTI_RET (Multi-antenna Remote Electrical Tilt), and STMA (Smart Towermounted NO Amplifier)must be set to ON. In actual running, the system may automatically set the ALD power supply switch of the antenna port to OFF when an ALD current abnormal alarm is reported. For details, see ALM-26530 RF Module ALD Current Abnormal.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the type of the ALD current alarm threshold. The current alarm thresholds for ALDs (excluding userdefined ALDs) must be selected according to the ALD type and connection mode. For 12 dB nonAISG TMAs only: the undercurrent alarm threshold is 30 mA, the undercurrent alarm NO clearance threshold is 40 mA, the overcurrent alarm threshold is 170 mA, and the overcurrent alarm clearance threshold is 150 mA. For 24 dB non-AISG TMAs only: the undercurrent alarm threshold is 40 mA, the undercurrent alarm clearance threshold is 60 mA, the overcurrent alarm threshold is Indicates the undercurrent alarm occur threshold. When the ALD current value is smaller than this threshold, an ALM- NO 26530 RF Module ALD Current Abnormal alarm is reported. The specific problem is undercurrent.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the undercurrent alarm clear threshold. When the ALD current value is greater than this NO threshold, the ALM26530 RF Module ALD Current Abnormal alarm is cleared.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the overcurrent alarm occur threshold. When the ALD current value is greater than this threshold, an ALM26530 RF Module ALD Current Abnormal alarm is reported. The specific problem is overcurrent. When the overcurrent alarm occur threshold is lower than the maximum NO current supported by the hardware, the overcurrent alarm threshold prevails. When the overcurrent alarm occur threshold is higher than the maximum current supported by the hardware, the maximum current supported by the hardware serves as the overcurrent alarm threshold.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the overcurrent alarm clear threshold. When the ALD current value is smaller than this threshold, the ALM26530 RF Module ALD Current Abnormal alarm is cleared. When the overcurrent alarm clear threshold is lower than the maximum value of current supported NO by the hardware, the overcurrent alarm threshold prevails. When the overcurrent alarm clear threshold is higher than the maximum current supported by the hardware, the maximum current supported by the hardware serves as the overcurrent alarm threshold. Indicates the present value of the NO current of the ALD. Indicates the actual status of the ALD NO power supply switch. Indicates the antenna type. This parameter can be NO set to SINGLE_RET or MULTI_RET.

NO

No

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the polarization type of the antenna. This parameter can be set to SINGLE or DUAL.

NO

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the connection scenario of the antenna. This parameter must be set based on the hardware installation. The vendor code and NO serial number of the device must be correctly configured in a non-regular scenario. This parameter can be set to REGULAR, DAISY_CHAIN.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the number of configured RET subunits. Indicates the antenna type of RET.

NO

NO

No

LOFD-001024 / TDLOFD-001024

NO

NO

Yes

None

Indicates the device number of the ALD. The device number YES of the ALD must be unique. Indicates the vendor code of the device NO in the scanning result. Indicates the serial number of the device in the scanning result. NO

YES

No

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the device name of the ALD, which identifies the ALD. The format of the name is as follows: site_sector_device type_network type. The meanings of the parts are as follows: Site: indicates the number of the BS site. It is uniformly assigned during the network planning. Sector: indicates NO the number of the sector. It is unique within a site. Device type: indicates the type of currently connected device. It can be SINGLE_RET (Single-antenna Remote Electrical Tilt Unit), MULTI_RET (Multiantenna Remote Electrical Tilt Unit), TMA (Towermounted Amplifier). Network type: Indicates the cabinet number of the RRU or RFU NO that controls the ALD.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the subrack number of the RRU or RFU that controls the ALD.

NO

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU NO or RFU that controls the ALD.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the actual protocol version of NO the ALD. Indicates the total number of ALD subunits. NO

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the vendor NO code.

NO

No

None

Indicates the serial number of the ALD. The vendor code NO and the serial number uniquely identify an ALD. Indicates the version information NO about the ALD hardware. Indicates the version information NO about the ALD software. Indicates the device NO model of the ALD.

NO

No

None

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the device NO type of the ALD.

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the port number of the RRU or RFU that controls the ALD. It will be NO NULL if the RRU/RFU does not support to report this parameter.

NO

Yes

None

Indicates the device YES number of the RET.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the RET subunit number. The number starts from 1. Each subunit shares the same High-Level Data Link Control (HDLC) address with the ALD.

YES

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the antenna azimuth.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the model of the RET antenna NO module.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the base station ID.AISG1.1based RET antennas support a maximum sector ID length of 4 characters. If the NO input sector ID has more than 4 characters, only the first 4 characters are saved on the RET antenna. Indicates the beamwidth of band 1. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern. Indicates the beamwidth of band 2. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern. Indicates the beamwidth of band 3. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern. Indicates the beamwidth of band 4. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 2.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 3.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 4.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the installation date.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the mechanical tilt of the installation.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the ID of the installer.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 2.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 3.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 4.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the sector NO ID.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the serial NO number of the ALD.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the maximum tilt supported by the RET subunit. Indicates the minimum tilt supported by the RET subunit.

NO

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 1.

NO

Yes

None

Indicates supported NO band 2.

NO

Yes

None

Indicates supported NO band 3.

NO

Yes

None

Indicates supported NO band 4.

NO

Yes

None

Indicates the beamwidth of band 1. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the beamwidth of band 2. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the beamwidth of band 3. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the beamwidth of band 4. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the gain of band 1. Indicates the gain of band 2. Indicates the gain of band 3. Indicates the gain of band 4. Indicates the cabinet number of the RRU where the RET port is located. NO NO NO NO

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO NO NO NO

Yes Yes Yes Yes

None None None None LOFD-001024 / TDLOFD-001024

YES

YES

No

Indicates the subrack number of YES the RRU where the RET port is located.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU YES where the RET port is located. Indicates the number of the RET antenna port on an YES RRU. This parameter is set to RET_PORT. Indicates the state of the ALD power supply switch. If SINGLE_RET(Singl e-antenna Remote Electrical Tilt) or MULTI_RET(Multiantenna Remote Electrical Tilt) is used, the ALD power supply switch must be set to ON. In actual running, the RRU/RFU automatically sets this switch to OFF for an RET port NO when the ALM26530 RF Module ALD Current Abnormal alarm is reported due to overcurrent, overcurrent protection, or undercurrent protection (the RRU/RFU supports undercurrent protection and Low Current Protect Switch is set to ON for the RRU/RFU) on the RET port.

YES

No

LOFD-001024 / TDLOFD-001024

YES

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the type of the ALD current alarm threshold. The current alarm threshold for the ALDs (excluding user-defined ALDs), that is, for RET antennas only (multiwire cable), must be selected according to the ALD type. The undercurrent alarm threshold is 10 mA, the NO undercurrent alarm clearance threshold is 15 mA, the overcurrent alarm threshold is 150 mA, and the overcurrent alarm clearance threshold is 120 mA. This parameter can be set to UER_SELF_DEFIN E or RET_ONLY_MULTI CORE. Indicates the undercurrent alarm occur threshold. When the ALD current value is smaller than this threshold, an ALM- NO 26530 RF Module ALD Current Abnormal alarm is reported. The specific problem is undercurrent.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the undercurrent alarm clear threshold. When the ALD current value is greater than this NO threshold, the ALM26530 RF Module ALD Current Abnormal alarm is cleared. Indicates the overcurrent alarm occur threshold. When the ALD current value is greater than this threshold, an ALM26530 RF Module ALD Current Abnormal alarm is reported. The specific problem is overcurrent. When the overcurrent alarm occur threshold is lower than the maximum NO current supported by the hardware, the overcurrent alarm threshold prevails. When the overcurrent alarm occur threshold is higher than the maximum current supported by the hardware, the maximum current supported by the hardware serves as the overcurrent alarm threshold.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the overcurrent alarm clear threshold. When the ALD current value is smaller than this threshold, the ALM26530 RF Module ALD Current Abnormal alarm is cleared. When the overcurrent alarm clear threshold is lower than the maximum value of current supported NO by the hardware, the overcurrent alarm threshold prevails. When the overcurrent alarm clear threshold is higher than the maximum current supported by the hardware, the maximum current supported by the hardware serves as the overcurrent alarm threshold. Indicates the present value of the NO current of the ALD. Indicates the actual status of the ALD NO power supply switch.

NO

No

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the device YES number of the RET.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the number of the RET subunit. The YES number starts from 1.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the online status of the NO subunit. Indicates the actual tilt of the RET NO subunit. Indicates the sector ID of the RET NO subunit.

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 None

NO

Yes

Indicates the cabinet number of the RRU or RFU NO that is connected to antenna port 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the subrack number of the RRU or RFU NO that is connected to antenna port 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU or RFU that is NO connected to antenna port 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the port number of the RRU or RFU that is NO connected to antenna port 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the cabinet number of the RRU or RFU that is connected to antenna port 2. This NO parameter is valid when a dualpolarized antenna is used.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the subrack number of the RRU or RFU that is connected to antenna port 2. This NO parameter is valid when a dualpolarized antenna is used.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU or RFU that is connected to antenna port 2. This NO parameter is valid when a dualpolarized antenna is used.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the port number of RRU that is connected to antenna port 2. This NO parameter is valid when a dualpolarized antenna is used.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the antenna tilt of the RET subunit.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the alarm error range for the NO tilt of the RET subunit. Indicates the name NO of the RET subunit. Indicates the number of configured TMA subunits.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

None

NO

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the device number of the ALD. The device number YES of the ALD must be unique. Indicates the vendor code of the device NO in the scanning result. Indicates the serial number of the device in the scanning result. NO

YES

No

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the device name of the ALD, which identifies the ALD. The format of the name is as follows: site_sector_device type_network type. The meanings of the parts are as follows: Site: indicates the number of the BS site. It is uniformly assigned during the network planning. Sector: indicates NO the number of the sector. It is unique within a site. Device type: indicates the type of currently connected device. It can be SINGLE_RET (Single-antenna Remote Electrical Tilt Unit), MULTI_RET (Multiantenna Remote Electrical Tilt Unit), TMA (Towermounted Amplifier). Network type: Indicates the cabinet number of the RRU or RFU NO that controls the ALD.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the subrack number of the RRU or RFU that controls the ALD.

NO

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU NO or RFU that controls the ALD.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the actual protocol version of NO the ALD. Indicates the total number of ALD subunits. NO

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the vendor NO code.

NO

No

None

Indicates the serial number of the ALD. The vendor code NO and the serial number uniquely identify an ALD. Indicates the version information NO about the ALD hardware. Indicates the version information NO about the ALD software. Indicates the device NO model of the ALD.

NO

No

None

NO

Yes

LOFD-001024 / TDLOFD-001024

NO

Yes

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

NO

Yes

Indicates the device NO type of the ALD.

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the port number of the RRU or RFU that controls the ALD. It will be NO NULL if the RRU/RFU does not support to report this parameter.

NO

Yes

None

Indicates the device YES number of the TMA.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the number of the TMA subunit. The number starts from YES 1. The subunit shares the same HDLC address with the ALD.

YES

No

LOFD-001024 / TDLOFD-001024

Indicates the antenna azimuth.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the base station ID.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the beamwidth of band 1. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the beamwidth of band 2. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern. Indicates the beamwidth of band 3. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern. Indicates the beamwidth of band 4. Beamwidth is used to describe the capability of the NO antenna to transmit RF signals. It is also used to measure the antenna pattern.

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 2.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 3.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of NO band 4.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the installation date.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the mechanical tilt of the installation.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the ID of the installer.

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 1.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 2.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 3.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates supported NO band 4.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the sector NO ID.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the serial NO number of the ALD.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the model of the RET antenna NO connected to the TMA. Indicates the maximum gain supported.

NO

No

LOFD-001024 / TDLOFD-001024

NO

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the minimum gain supported.

NO

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the type of TMA subunit. It indicates whether the VS NO measurement and the bypass mode are supported.

NO

Yes

None

Indicates the step NO for the gain change.

NO

Yes

None

Indicates supported NO band 1.

NO

Yes

None

Indicates supported NO band 2.

NO

Yes

None

Indicates supported NO band 3.

NO

Yes

None

Indicates supported NO band 4.

NO

Yes

None

Indicates the beamwidth of band 1. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the beamwidth of band 2. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the beamwidth of band 3. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the beamwidth of band 4. Beamwidth describes the capability of an NO antenna to transmit RF signals. It also defines the width of the antenna pattern. Indicates the gain of NO band 1. Indicates the gain of NO band 2.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the gain of NO band 3. Indicates the gain of NO band 4.

NO NO

Yes Yes

None None

Indicates the lowest RX frequency band NO of the subunit.

NO

Yes

None

Indicates the highest TX frequency band of the subunit.

NO

NO

Yes

None

Indicates the lowest TX frequency band NO of the subunit.

NO

Yes

None

Indicates the highest RX frequency band of the subunit.

NO

NO

Yes

None

Indicates the device YES number of the TMA. Indicates the number of the TMA YES subunit, which starts from 1. Indicates the sector ID of the TMA NO subunit. Indicates the actual gain of the TMA NO subunit. Indicates the actual working mode of the NO TMA subunit.

YES

No

LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024 LOFD-001024 / TDLOFD-001024

YES

No

NO

Yes

NO

Yes

NO

Yes

Indicates the online status of the TMA NO subunit.

NO

Yes

LOFD-001024 / TDLOFD-001024

Indicates the number of the antenna port to which the TMA subunit is connected. Indicates the cabinet number of the RRU or RFU that provides the antenna port to which the TMA subunit is connected.

NO

NO

No

LOFD-001024 / TDLOFD-001024

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the slot number of the RRU or RFU that provides the NO antenna port to which the TMA subunit is connected. Indicates the subrack number of the RRU or RFU that provides the antenna port to which the TMA subunit is connected.

NO

No

LOFD-001024 / TDLOFD-001024

NO

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the gain of the TMA subunit.If this parameter is set NO to 255, it is invalid and the actual gain is not changed.

NO

No

LOFD-001024 / TDLOFD-001024

Indicates the working mode of the TMA subunit. If the TMA subunit works in BYPASS mode, it does not amplify the uplink signals.If this NO parameter is set to DEVICE_DEFAULT _VALUE, it is invalid and the actual mode is not changed. Indicates the cabinet number of the AAU where the YES virtual antenna port is located. Indicates the subrack number of the AAU where the YES virtual antenna port is located. Indicates the slot number of the AAU where the virtual YES antenna port is located.

NO

No

LOFD-001024 / TDLOFD-001024

YES

No

None

YES

No

None

YES

No

None

Indicates the number of the YES virtual antenna port.

YES

No

None

Indicates the device number of the YES virtual RET antenna.

YES

No

None

Indicates the cabinet number of the AAU where the NO virtual RET antenna is located. Indicates the subrack number of the AAU where the NO virtual RET antenna is located. Indicates the slot number of the AAU where the virtual NO RET antenna is located.

YES

No

None

YES

No

None

YES

No

None

Indicates the device name of the virtual NO RET antenna.

YES

No

None

Indicates the number of subunits NO contained in the virtual RET antenna. Indicates the cabinet number of the AAU where the NO virtual RET subunit is located.

NO

No

None

YES

No

None

Indicates the number of the first virtual antenna port NO to which the virtual RET subunit is connected.

NO

No

None

Indicates the number of the second virtual antenna port to which the virtual RET subunit is connected.

NO

NO

No

None

Indicates the device name of the virtual NO RET subunit. Indicates the device number of the virtual RET antenna YES where the virtual RET subunit is contained. Indicates the polarization type of the virtual antenna NO port 1 to which the virtual RET subunit is connected. Indicates the slot number of the AAU where the virtual NO RET subunit is located. Indicates the subrack number of the AAU where the NO virtual RET subunit is located. Indicates the number of the YES virtual RET subunit.

YES

No

None

YES

No

None

NO

No

None

YES

No

None

YES

No

None

YES

No

None

Indicates the number of the third virtual antenna port NO to which the virtual RET subunit is connected.

NO

No

None

Indicates the polarization type of the virtual antenna NO port 2 to which the virtual RET subunit is connected. Indicates the downlink tilt of the virtual RET subunit. If this parameter is NO set to 32767, it is invalid and the actual tilt is not changed. Indicates the uplink tilt of the virtual RET subunit. If this parameter is set to NO 32767, it is invalid and the actual tilt is not changed.

NO

No

None

NO

No

None

NO

No

None

Indicates the number of the fourth virtual antenna port NO to which the virtual RET subunit is connected.

NO

No

None

Indicates the polarization type of the virtual antenna NO port 3 to which the virtual RET subunit is connected. Indicates the polarization type of the virtual antenna NO port 4 to which the virtual RET subunit is connected. Indicates the number of ports that NO can be added to a virtual RET subunit. Indicates the number of the control link at the local end. Indicates the cabinet number of the local node at one end of the control link. Indicates the subrack number of the local node at one end of the control link. YES

NO

No

None

NO

No

None

NO

No

None

YES

No

None

NO

YES

No

None

NO

YES

No

None

Indicates the slot number of the local NO node at one end of the control link. Indicates the cabinet number of the upper-level node at the other end of the control link. Indicates the

YES

No

None

NO

YES

No

None

subrack number of the upper-level NO node at the other end of the control link. Indicates the slot number of the upperlevel node at the NO other end of the control link. Indicates the port number of the upperlevel node at the other end of the NO control link.Values 0 to 4 indicate the ports M0 to M4 on the board panel. Indicates the number of the port whose control link status is queried. When this parameter is set to a value within the range from 0 to 4, this parameter indicates a primary port on the UCIU board. When this parameter is set to 8, this parameter indicates the secondary port on the UCIU and UMPT board. Indicates the start time of the measurement.

YES

No

None

YES

No

None

YES

No

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the number of error packets within the NO measurement periods in the latest one day. Indicates the ratio of the number of error packets to that of received packets NO within the measurement periods in the latest one day. Indicates the ratio of the Loss Of Signal (LOS) duration to one day. The LOS duration is NO measured within the measurement periods in the latest one day. Indicates the Loss Of Signal (LOS) duration measured within the NO measurement periods in the latest one day. Indicates the number of error packets within the NO measurement periods in the latest one hour. Indicates the ratio of the number of error packets to that of received packets NO within the measurement periods in the latest one hour. Indicates the ratio of the Loss Of Signal (LOS) duration to one hour. The LOS duration is NO measured within the measurement periods in the latest one hour.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the Loss Of Signal (LOS) duration measured within the NO measurement periods in the latest one hour. Indicates the number of error packets within the NO measurement periods in the latest one week. Indicates the ratio of the number of error packets to that of received packets NO within the measurement periods in the latest one week. Indicates the ratio of the Loss Of Signal (LOS) duration to one week. The LOS duration is NO measured within the measurement periods in the latest one week. Indicates the Loss Of Signal (LOS) duration measured within the NO measurement periods in the latest one week. Indicates the total number of error packets within the measurement periods. Indicates the total Loss Of Signal (LOS) duration within the measurement periods. Indicates the total length of measurement periods.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the total number of received packets within the NO measurement periods. Indicates the number of the BITS YES clock link. Indicates the number of the cabinet where the BITS clock link is configured. Indicates the number of the subrack where the BITS clock link is configured. Indicates the number of the slot where the BITS clock link is configured.

NO

Yes

None

NO

No

None

NO

NO

No

None

NO

NO

No

None

NO

NO

No

None

Indicates the activation status of the BITS clock link. If the link is active, NO the BITS clock link is the current clock source of the system. Indicates the availability of a BITS clock link. Only an available clock link can serve as the current clock NO source. Otherwise, the clock link cannot be locked even if it is activated.

NO

Yes

None

NO

Yes

None

Indicates the priority of the clock source. The value 1 indicates that the current clock source has the highest NO priority, and the value 4 indicates that the current clock source has the lowest priority. Indicates the number of the E1/T1 line clock link.

NO

No

None

YES

NO

No

None

Indicates the number of the cabinet where the NO E1/T1 line clock link is configured. Indicates the number of the subrack where the NO E1/T1 line clock link is configured. Indicates the number of the slot where the E1/T1 line clock link is configured. Indicates the number of the port where the E1/T1 line clock link is configured.

NO

No

None

NO

No

None

NO

NO

No

None

NO

NO

No

None

Indicates the activation status of the E1/T1 line clock link. If the link is NO active, the E1/T1 line clock link is the current clock source of the system.

NO

Yes

None

Indicates the availability of the E1/T1 line clock link. Only an available clock link can serve as the current clock source. Otherwise, the clock link cannot be locked even if it is activated.

NO

NO

Yes

None

Indicates the priority of the clock source. The value 1 indicates that the current clock source has the highest NO priority, and the value 4 indicates that the current clock source has the lowest priority. Indicates the number of the peer YES reference clock link. Indicates the standard of the peer reference clock. The standard of the peer reference NO clock is another standard in the same BBU subrack by default. Indicates the activation status of the peer reference clock link. If the link is active, the peer NO reference clock link is the current clock source of the system.

NO

No

None

NO

No

None

NO

No

None

NO

Yes

None

Indicates the availability of the peer reference clock link. Only an available clock link can serve as the current clock source. Otherwise, the clock link cannot be locked even if it is activated.

NO

NO

Yes

None

Indicates the number of a TOD clock link. The number of the TOD clock link must correspond to the number of the TOD YES port on the USCUb or UMPT. For example, clock link No.0 corresponds to port No.0, clock link No.1 corresponds to port No.1. Indicates the type of a TOD clock link. It indicates whether the corresponding TOD port is an input or output port. An input port is used to input clock signals NO to the BS, and an output port is used to provide clock signals for other BSs. Only the TOD clock of input type can serve as a clock source. Indicates the number of the cabinet where the TOD clock link is configured. Indicates the number of the subrack where the TOD clock link is configured.

NO

No

None

NO

No

None

NO

NO

No

None

NO

NO

No

None

Indicates the number of the slot where the TOD clock link is configured.

NO

NO

No

None

Indicates the type of TOD feeder, which can only be the NO twisted-pair cable currently. Indicates the length of the TOD feeder. The feeder delay is calculated on the basis of the TOD feeder length to ensure the clock accuracy. The clock accuracy is affected NO if there is an excessively large difference (about 20 m) between the value of this parameter and the actual feeder length.

NO

No

None

NO

No

None

Indicates the activation status of a TOD clock link. If the link is active, NO the TOD clock link is the current clock source of the system. Indicates the availability of an TOD clock link. Only an available clock link can serve as the current clock NO source. Otherwise, the clock link cannot be locked even if it is activated. Indicates the feeder delay of the TOD clock link. If the feeder delay is not NO supported by the satellite card, this parameter is set to NULL. Indicates the priority of the clock source. The value 1 indicates that the current clock source has the highest NO priority, and the value 4 indicates that the current clock source has the lowest priority.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

No

None

Indicates the number of the GPS YES clock link.

NO

No

None

Indicates the cabinet number of the board where the NO satellite card is attached.

NO

No

None

Indicates the subrack number of the board where the NO satellite card is attached. Indicates the slot number of the board NO where the satellite card is attached.

NO

No

TDLOFD-009001

NO

No

None

Indicates the mode to obtain the NO position of the GPS satellite.

NO

No

None

Indicates the longitude of the GPS antenna. A negative value indicates the west longitude, and a positive value indicates the east longitude.

NO

NO

No

None

Indicates the latitude of the GPS antenna. A negative value indicates the NO south latitude, and a positive value indicates the north latitude. Indicates the altitude of the GPS antenna. A negative value indicates that the GPS antenna is NO below the sea level, and a positive value indicates that the GPS antenna is above the sea level. Indicates the antenna angle, which is the angle with the horizontal line.

NO

No

None

NO

No

None

NO

NO

No

None

Indicates the delay of the GPS feeder. Some satellite cards NO do not support querying of this information.

NO

Yes

None

Indicates the duration for tracing the position of the GPS satellite.

NO

NO

No

None

Indicates the precision requirement for NO tracing the position of the GPS satellite. Indicates the type of the GPS feeder, which can be the twisted-pair cable or coaxial cable. The board-mounted NO GPS antenna uses the coaxial cable. The RGPS antenna uses the twistedpair cable.

NO

No

None

NO

No

None

Indicates the length of the GPS feeder. The actual feeder length is the one between the GPS receiver and the board connected to the GPS antenna. The feeder delay is calculated on the NO basis of the GPS feeder length to increase the clock accuracy. The clock accuracy is affected if the configured feeder length is 20 m greater than the actual feeder length. Indicates the software version of NO the satellite receiver. Indicates whether the position of the GPS satellite is locked by the GPS reference receiver. Indicates whether the calendar information of the GPS reference receiver is valid. Indicates whether the GPS satellite positioned by the GPS reference receiver is valid.

NO

No

None

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates whether the position of the GPS satellite is set NO on the GPS reference receiver. Indicates the clock adjusting state of the GPS reference receiver. Indicates whether the clock mode of the GPS reference receiver is valid. NO

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the number of locked GLONASS satellites.

NO

NO

Yes

None

Indicates the physical status of the satellite card, which can be NOTEXIST (Inexistent), ANTENNASHORTE D (Antenna Shorted), ANTENNAOPENE D (Antenna Opened), SELF_CHECK_FAI LURE (Self-check NO Failure), COMEXCEPTION (COM Port Communication Fault), NORMAL (Normal), UNKNOWN (Unknown Exception), USCUINVALID (USCU Invalid), or UNKNOWN_STAR _CARD (Unknown Star Card).

NO

Yes

None

Indicates the physical type of the satellite card, which can be M12M, UT, RT, K161, GG16, JNS100, RGPS, NO CWAIN, RTSMT, UBLOX5, BD7702, NAVIOR, PPSTOD, M1000, TRGPS, BD7702CMS, or OEM4.

NO

Yes

None

Indicates the number of locked NO GPS satellites. Indicates the working mode of the satellite card, which can be GPS, GLONASS, COMPASS, GPS/GLONASS, COMPASS/GPS with COMPASS prioritized, and GPS/COMPASS with GPS prioritized. Satellite cards are classified into dual-mode satellite cards and single-mode NO satellite cards. A dual-mode satellite card supports two satellite searching modes. For example, the working mode of a COMPASS/GPS satellite card can be COMPASS prioritized or GPS prioritized. In COMPASS prioritized mode, the satellite card processes signals from COMPASS Indicates the number of locked NO COMPASS satellites. Indicates the activation status of the GPS clock link. If the link is active, NO the GPS clock link is the current clock source of the system.

NO

Yes

None

NO

No

None

NO

Yes

None

NO

Yes

None

Indicates the priority of the clock source. The value 1 indicates the current clock source has NO the highest priority, and the value 4 indicates the current clock source has the lowest priority.

NO

No

None

Indicates the number of the IP clock link.

YES

NO

No

None

Indicates the type of the IP clock protocol, which can be PTP or Huawei proprietary protocol. PTP includes IEEE1588 V2 and G.8265.1. IEEE1588 V2, defined by the IEEE, supports both time synchronization and frequency synchronization. NO G.8265.1 supports frequency synchronization only. Huawei proprietary protocol, which is the Huaweidefined IP clock protocol, applies to the interconnection between Huawei equipment and supports frequency synchronization only.

NO

No

LOFD-00301302 / TDLOFD-00301302 LOFD-00301303

Indicates the number of the cabinet where the IP clock link is configured. Indicates the number of the subrack where the IP clock link is configured. Indicates the number of the slot where the IP clock link is configured.

NO

NO

No

None

NO

NO

No

None

NO

NO

No

None

Indicates the client IPv4 address of the NO IP clock link.

NO

No

LOFD-00301302 / TDLOFD-00301302 LOFD-00301303

Indicates the server IPv4 address of the NO IP clock link.

NO

No

LOFD-00301302 / TDLOFD-00301302 LOFD-00301303

Indicates the domain to which the IP clock link belongs. The setting NO of this parameter must be the same as the setting of the clock server.

NO

No

LOFD-00301302 / TDLOFD-00301302

Indicates the compensation mechanism for the transmission delay between the Time Server and BS. When the Boundary clock or Transparent clock is not supported on the transport network, this parameter can be set to E2E only. When the Boundary clock or Transparent clock is NO supported on the transport network, this parameter is set to P2P. There are two application modes for IEEE1588 V2: the Point-to-Point mode (P2P) and End-toEnd mode (E2E). The Point-to-Point mode, also known as the fullsupported mode, involves all clock nodes: the OC, BC, and TC. This mode

NO

No

None

Indicates whether the BMC (Best Master Clock) algorithm is enabled or not. ON indicates that the BMC NO algorithm is enabled, and OFF indicates that the BMC algorithm is disabled.

NO

No

None

Indicates the priority configured by the user for the BMC (Best Master Clock) algorithm. The information about the priority can be collected from the Time Server. This parameter specifies the clock quality NO that is anticipated by the user. The Time Server with the matching clock quality is selected as the target server. Class0 has the highest priority, and Class0 to Class3 indicate priorities in descending order.

NO

No

None

Indicates the priority configured by the user for the BMC (Best Master Clock) algorithm. The information about the priority can be collected from the Time Server. This parameter specifies the clock quality NO that is anticipated by the user. The Time Server with the matching clock quality is selected as the target server. Class0 has the highest priority, and Class0 to Class3 indicate priorities in descending order.

NO

No

None

Indicates the priority configured by the user for the BMC (Best Master Clock) algorithm. The information about the priority can be collected from the Time Server. This parameter specifies the clock quality NO that is anticipated by the user. The Time Server with the matching clock quality is selected as the target server. Class0 has the highest priority, and Class0 to Class3 indicate priorities in descending order.

NO

No

None

Indicates the priority configured by the user for the BMC (Best Master Clock) algorithm. The information about the priority can be collected from the Time Server. This parameter specifies the clock quality NO that is anticipated by the user. The Time Server with the matching clock quality is selected as the target server. Class0 has the highest priority, and Class0 to Class3 indicate priorities in descending order.

NO

No

None

Indicates the current priority class NO of the IP clock link.

NO

Yes

None

Indicates whether the clock source is specified.

NO

NO

No

None

Indicates the MAC address of the clock source for the IP clock server. The NO MAC address must be in the format of XXXX-XXXX-XXXX.

NO

No

None

Indicates the activation status of the IP clock link. If the IP clock link is NO active, it is the current clock source of the system. Indicates the availability of the IP clock link. Only an available clock link can serve as the current clock NO source. Otherwise, the clock link cannot be locked even if it is activated. Indicates the networking type for NO the IP clock.

NO

Yes

None

NO

Yes

None

NO

No

LOFD-00301302 / TDLOFD-00301302

Indicates the compensation for asymmetry of IP clock links.

NO

NO

No

LOFD-00301302 / TDLOFD-00301302

Indicates the step mode, which can be NO ONE_STEP or TWO_STEP. Indicates the selfacquired VLAN ID NO of the IP clock server. Indicates the offset of the Universal NO Time Coordinated (UTC).

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the priority of the clock source. The value 1 indicates that the current clock source has the highest NO priority, and the value 4 indicates that the current clock source has the lowest priority. Indicates the frequency at which the clock source sends announcement packets based on its negotiation with the BS. Indicates the frequency at which the clock source sends synchronization packets based on its negotiation with the BS.

NO

No

None

NO

NO

No

None

NO

NO

No

None

Indicates the priority of the IP clock server. The value 0 indicate the highest priority, and the value 255 indicates the lowest priority.If two IP clock servers are required, the value of this parameter is used NO to identify the active and standby IP clock servers. The IP clock server with a higher priority serves as the active server and the IP clock server with a lower priority serves as the standby server.

NO

No

None

Indicates the type of protocol supported by the IEEE 1588 V2-compliant IP clock link, which can be ITU-T G.8265.1 or IEEE 1588 V2. ITU-T G.8265.1 is defined by the International Telecommunication Union (ITU) for frequency synchronization of an IEEE 1588 V2compliant IP clock link with the NO networking type of UNICAST. An IP clock link in compliant with ITUT G.8265.1 supports interconnection with servers from other vendors. An IP clock link in compliant with IEEE 1588 V2 does not support interconnection with servers from other vendors.

NO

No

None

Indicates the interval at which negotiations are performed between the BS and IP clock NO server. After the interval elapses, the BS initiates another negotiation with the IP clock server.

NO

No

None

Indicates the version of the IP address.

NO

NO

No

None

Indicates the client IPv6 address of the NO IP clock link.

NO

No

None

Indicates the server IPv6 address of the NO IP clock link.

NO

No

None

Indicates the number of the synchronousEthernet clock link. YES Currently, only one link (link No.0) can be configured. Indicates the number of the cabinet where the synchronousEthernet clock link is configured. Indicates the number of the subrack where the synchronousEthernet clock link is configured. Indicates the number of the slot where the synchronousEthernet clock link is configured.

NO

No

None

NO

NO

No

None

NO

NO

No

None

NO

NO

No

None

Indicates the number of the port where the synchronousEthernet clock link is configured. Indicates whether handling of SSM frames is supported. SSM: Synchronization Status Message. Recommendation ITU-T G.8264/Y.1364.

NO

NO

No

None

NO

NO

No

None

Indicates the activation status of a synchronousEthernet clock link. If the link is active, NO the synchronousEthernet clock link is the current clock source of the system. Indicates the availability of a synchronousEthernet clock link. Only an available clock link can serve NO as the current clock source. Otherwise, the clock link cannot be locked even if it is activated. Indicates the priority of the clock source. The value 1 indicates that the current clock source has the highest NO priority, and the value 4 indicates that the current clock source has the lowest priority.

NO

Yes

LOFD-00301301

NO

Yes

LOFD-00301301

NO

No

None

Indicates the availability of the clock source. Only an available clock link can serve as the current clock source. Otherwise, the clock link cannot be locked even if it is activated.

NO

NO

Yes

None

Indicates whether a clock source is licensed to be used. Only a licensed NO clock source can serve as the current clock source. Indicates the priority of the clock source. The value 1 indicates that the current clock source has the highest NO priority, and the value 4 indicates that the current clock source has the lowest priority. Indicates the clock link number of the reference clock source. When this parameter is set to AUTO, the system selects an available clock link from those of the NO specified reference clock source. If there is more than one clock link and the selected clock link fails, another available clock link will be used.

NO

Yes

None

NO

Yes

None

NO

No

None

Indicates the type of the user-selected NO clock source.

NO

No

None

Indicates the working mode of the system clock. Manual indicates that a clock source must be specified by the user. Auto indicates that the system automatically selects a clock source based on NO the priority and availability of the clock source. Free indicates that the system clock works in free-running mode, that is, the system clock does not trace any reference clock source.

NO

No

LBFD-00300501 / TDLBFD-00300501

Indicates the clock synchronization mode of a BS, which can be frequency synchronization or time synchronization.

NO

NO

No

None

Indicates the status of the current clock source, which can be Normal, Lost, Unavailable, Jitter, NO Frequency Deviation, Phaseoutscope, or Inconsistent Clock References.

NO

Yes

None

Indicates the working mode of the clock. It also indicates whether the system clock is stable. The working NO mode of the clock can be Fast tracking, Locked, Holdover, or Free running.

NO

Yes

None

Indicates the clock source in use.

NO

NO

Yes

None

Indicates the number of the cabinet where the system clock is located.

NO

NO

Yes

None

Indicates the number of the subrack where the system clock is located.

NO

NO

Yes

None

Indicates the number of the slot where the system clock is located.

NO

NO

Yes

None

Indicates the clock quality level of the BS. The values for this parameter are listed in quality descending order. NO QL-PRC indicates the highest quality level and QL-DNU indicates the lowest quality level.

NO

No

None

Indicates the cabinet number of the baseband processing board. Indicates the subrack number of the baseband processing board.

YES

NO

No

None

YES

NO

No

None

Indicates the slot number of the baseband processing board.

YES

YES

No

None

Indicates the type of NO the board.

NO

No

None

Indicates the working mode of a baseband processing board. There are five working modes: FDD, TDD, TDD BF, TDD_8T8R, and TDD_TL. FDD is short for Frequency Division Duplex. In FDD mode, the baseband processing board carries traditional voice and data NO services. TDD is short for Time Division Duplex. The value TDD_ENHANCE indicates the TDD mode integrated with the BeamForming (BF) function. The BF function provides the data transmission service in transmission mode 7 and 8 defined in protocols. For Indicates the administrative state of the board. The administrative state of the board can be NO locked, unlocked, or shutting down. For details, see ITU-T X.731. Indicates the scheduled duration NO before a board is blocked.

NO

No

None

NO

No

None

NO

No

None

Indicates the block type of the board. IMMEDIATE (Immediate): indicates that the board is blocked and services carried by the board are interrupted immediately after NO the command is executed. DELAY (Delay): indicates that the board is blocked and services carried by the board are interrupted after a scheduled duration.

NO

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the cabinet where the YES BBU FAN unit is located. Indicates the number of the subrack where the BBU FAN unit is located.

NO

Yes

None

NO

No

None

YES

NO

No

None

Indicates the number of the slot YES where the BBU FAN unit is located. Indicates the current temperature NO of the BBU FAN unit.

YES

No

None

NO

Yes

None

Indicates the rotation speed of a fan in the BBU, which is the ratio of NO the current rotation speed of the fan to its maximum rotation speed.

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the cabinet number of the CCU.

NO

Yes

None

YES

YES

No

None

Indicates the subrack number of the CCU.

YES

NO

No

None

Indicates the slot YES number of the CCU.

NO

No

None

Indicates the cabinet number of NO the manager unit of the CCU. Indicates the subrack number of NO the manager unit of the CCU. Indicates the number of the serial NO port to which the CCU is connected. Indicates whether the CCU is directly connected to its NO manager unit, which is a BBU. Indicates the position of the CCU NO on a CCU chain. Indicates the working standard of the manager unit to NO which the CCU is connected. Indicates whether to allow the report of a dedicated Boolean alarm. If the shield NO flag for a Boolean alarm is enabled, the Boolean alarm cannot be reported. Indicates the connecting status of NO the port on the left of the CCU. Indicates the connecting status of the port on the right of the CCU. Indicates the software version of the CCU. Indicates the PCB version of the CCU. Indicates the erasable programmable logic device (EPLD) version of the CCU. NO

NO

No

None

NO

No

None

NO

No

None

NO

No

None

YES

No

None

NO

No

None

NO

No

None

NO

Yes

None

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the ID of YES the RRU chain/ring. Indicates the current Common Public Radio Interface (CPRI) NO line rate at the head of the RRU chain/ring. Indicates the negotiation state of the Common Public Radio Interface (CPRI) port, which can be NOTREADY(Not ready), NEGOTIATING(Ne gotiating), NEGOTIATED(Neg otiated), TIMEOUT(Timeout) , or USERCONFIG(US ERCONFIG). The value NO NOTREADY(Not ready) indicates that the rate negotiation has not been started. The value NEGOTIATING(Ne gotiating) indicates that the rate is being negotiated. The value NEGOTIATED(Neg otiated) indicates that the rate negotiation is complete. The value TIMEOUT(Timeout) indicates that the Indicates the current Common Public Radio NO Interface (CPRI) line rate at the tail of the RRU chain/ring.

NO

No

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the negotiation state at the tail of the CPRI ring, which can be NOTREADY(Not ready), NEGOTIATING(Ne gotiating), NEGOTIATED(Neg otiated), TIMEOUT(Timeout) , or USERCONFIG(US ERCONFIG). The value NOTREADY(Not ready) indicates that the rate negotiation has not been started. The value NEGOTIATING(Ne gotiating) indicates that the rate is being negotiated. The value NEGOTIATED(Neg otiated) indicates that the rate negotiation is complete. The value TIMEOUT(Timeout) indicates that the rate negotiation timed out due to a Indicates the cabinet number. Indicates the subrack number. Indicates the slot number. Indicates the number of an RRU carried on the RRU chain/ring. The RRUs are numbered from 0 in ascending order. If the RRU chain is connected to the ports located on the baseband processing boards, the first port is the head of the chain, and the last port is the tail of the chain.

NO

NO

Yes

None

NO NO NO

NO NO NO

Yes Yes Yes

None None None

NO

NO

Yes

None

Indicates the maximum bit rate at the Common Public Radio Interface (CPRI) port. If the maximum bit rate is NULL, the RF NO module or baseband interface board does not support the rate negotiation, or the rate negotiation fails.

NO

Yes

None

Indicates the cabinet number of the board where the CPRI port is located. This parameter is configured automatically when the CPRI port is created. A CPRI YES port is created automatically when a BBP is added by running the ADD BRD command. The CPRI port is used for the configuration check when an RRU chain/ring is added.

NO

No

None

Indicates the subrack number of the board where the CPRI port is located. This parameter is configured automatically when the CPRI port is created. A CPRI YES port is created automatically when a BBP is added by running the ADD BRD command. The CPRI port is used for the configuration check when an RRU chain/ring is added.

NO

No

None

Indicates the slot number of the board where the CPRI port is located. This parameter is configured automatically when the CPRI port is created. A CPRI port is created YES automatically when a BBP is added by running the ADD BRD command. The CPRI port is used for the configuration check when an RRU chain/ring is added.

YES

No

None

Indicates the optical port number of the board where the CPRI port is located. This parameter is configured automatically when the CPRI port is created. A CPRI YES port is created automatically when a BBP is added by running the ADD BRD command. The CPRI port is used for the configuration check when an RRU chain/ring is added.

YES

No

None

Indicates the rate at NO the CPRI port.

NO

Yes

None

Indicates the administrative state of the CPRI port. When the CPRI port is locked, it indicates that a breakpoint is configured on the RRU chain/ring. At this moment, although the optical cables are connected, the NO CPRI link is disconnected. The breakpoint is configured to prevent temporary alarms from being reported during network operations. When the CPRI port is unlocked, it indicates that there is no breakpoint on the RRU chain/ring.

NO

Yes

None

Indicates the inposition state of the NO CPRI port. Indicates the mode of the CPRI port. There are two NO modes: Maser and Slave.

NO

Yes

None

NO

Yes

None

Indicates the type of NO the CPRI port.

NO

Yes

None

Indicates the backup mode of the CPRI port. Indicates the channel type of the CPRI port. Indicates the DL bandwidth of the CPRI port. Indicates the number of downlink connections of the CPRI port. Indicates the number of uplink connections of the CPRI port. Indicates the Mux Status of the CPRI port.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the power consumption NO measurement point of the BS. Indicates the cabinet number of the main control and transmission board. Indicates the subrack number of the main control and transmission board.

NO

No

None

YES

NO

No

None

YES

NO

No

None

Indicates the slot number of the main YES control and transmission board. Indicates the type of NO the board.

YES

No

None

YES

No

None

Indicates the active or standby status of the main control and transmission board. The active or standby status is NO available only to the main control and transmission board. This parameter for other types of board is set to NULL.

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the YES cabinet where the PEU is located. Indicates the number of the subrack where the PEU is located. YES

NO

Yes

None

NO

No

None

NO

No

None

Indicates the number of the slot YES where the PEU is located. Indicates the spare NO power of the UPEU. Indicates the spare NO power of the BBU.

YES

No

None

NO NO

Yes Yes

None None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates whether the PSU intelligent shutdown switch in NO a BS is enabled or disabled. Indicates the cabinet number of the optical or electrical module. Indicates the subrack number of the optical or electrical module. Indicates the slot number of the optical or electrical module. YES

NO

Yes

None

NO

No

None

YES

No

None

YES

YES

No

None

YES

YES

No

None

Indicates the number of the optical or electrical module. If a UCIU is queried, values 0 to 4 indicate the ports M0 to M4 on the board panel, and value 8 indicates the port S0 on the YES board panel. If a UMPT is queried, value 8 indicates the port CI on the board panel. If a LBBPd board is queried, value 6 indicates the port HEI on the board panel. Indicates whether the optical or NO electrical module is in position.

YES

No

None

NO

Yes

None

Indicates the type of the optical or electrical module, which can be SFP, enhanced SFP, or electrical port. These three types are different in the supported transmission rates and transmission distance. The transmission distance of the electrical port is short, so it is used NO to connect the BBU or RFU. The Small Form-factor Pluggable (SFP) is a small hotswappable module, which can be connected to an optical module or an electrical module. The difference between the enhanced SFP and SFP is the supported transmission rates. Indicates the manufacturer of the NO optical or electrical module. Indicates the transmission mode of the optical NO module, that is, single-mode or multimode. Indicates the wavelength of the NO optical module. Indicates the transmission code NO rate of the optical or electrical module.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the maximum distance that signals from the optical module can travel along a singlemode optical fiber with a 9-micrometer NO core diameter. The value 0 indicates that the optical module does not support this type of optical fiber. Indicates the maximum distance that signals from the optical module can travel along a singlemode optical fiber with a 9-micrometer NO core diameter. The value 0 indicates that the optical module does not support this type of optical fiber. Indicates the maximum distance that signals from the optical module can travel along a multimode optical fiber with a 50NO micrometer core diameter. The value 0 indicates that the optical module does not support this type of optical fiber. Indicates the maximum distance that signals from the optical module can travel along a multimode optical fiber with a 62.5NO micrometer core diameter. The value 0 indicates that the optical module does not support this type of optical fiber.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the observed temperature of the optical module. This NO parameter is valid only when the optical module type is ESFP. Indicates the observed voltage of the optical module. This parameter is NO valid only when the optical module type is ESFP. Indicates the observed current of the optical module. This parameter is NO valid only when the optical module type is ESFP. Indicates the TX optical power of the optical module. This parameter is valid NO only when the optical module type is ESFP. Indicates the RX optical power of the optical module. This parameter is valid NO only when the optical module type is ESFP. Indicates the transmission distance of the electrical module.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the cabinet number of YES the extension transmission board. Indicates the subrack number of YES the extension transmission board. Indicates the slot number of the YES extension transmission board.

NO

No

None

NO

No

None

YES

No

None

Indicates the type of NO the sub-board. Indicates the active or standby status of the extended NO transmission processing board.

YES

No

None

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the cabinet number of the UCIU. Indicates the subrack number of the UCIU. Indicates the slot number of the UCIU.

NO

NO

Yes

None

YES

YES

No

None

YES YES

YES YES

No No

None None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the YES cabinet where the UEIU is located. Indicates the number of the subrack where the UEIU is located. Indicates the number of the slot where the UEIU is located. YES

NO

Yes

None

NO

No

None

NO

No

None

YES

YES

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the YES cabinet where the USCU is located. Indicates the number of the subrack where the USCU is located. YES

NO

Yes

None

NO

No

None

NO

No

None

Indicates the number of the slot YES where the USCU is located.

YES

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the deployment ID. The parameter value can contain digits, letters, left parenthesis ((), right NO parenthesis ()), underlines (_), dots (.), ampersands (&), is less than (<), and is greater than (>). Indicates the battery intelligent management switch status. Intelligent battery power NO management prolongs the lifespan of a battery using the floating charge mode.

NO

Yes

None

NO

No

None

NO

No

None

Whether to allow the generation of the Power Lose Redundancy alarm. The PSUs needs to be configured in N+1 backup mode. When this NO parameter is set to "YES", the BTS reports the Power Lose Redundancy alarm if the PSUs are not configured in N+1 mode.

NO

No

None

Indicates the special alarm status of the NE. The status is set to NO TESTING by default by the manufacturers.

NO

No

None

Indicates the start time of special alarm status of the NE. If the start time NO is not specified, the special alarm status takes effect immediately.

NO

No

None

Indicates the end time of special alarm status of the NE.

NO

NO

No

None

Indicates the remarks of special alarm status of the NE.

NO

YES

No

None

Indicates the current maintenance mode NO of the network element (NE).

NO

Yes

None

Indicates the direct voltage alarm switch. The switch controls whether to report the ALMNO 26113 Base Station DC Power Supply Abnormal in the case of low voltage.

NO

No

None

Indicates the DC voltage alarm occured threshold. When the load voltage is lower than the DC voltage alarm occured threshold and the NO direct voltage alarm switch is set to ENABLE, an ALM26113 Base Station DC Power Supply Abnormal is reported. Indicates the DC voltage alarm restored threshold. When the load voltage is higher than the DC voltage alarm restored threshold and the NO direct voltage alarm switch is set to ENABLE, an ALM26113 Base Station DC Power Supply Abnormal is cleared.

NO

No

None

NO

No

None

Indicates the cabinet number.

YES

YES

No

None

Type of a cabinet. This parameter is set to VIRTUAL when the type of a NO cabinet is not within the value range of this parameter.

NO

No

None

Indicates a brief description of the cabinet, which can be the function, NO location, and some other information of the cabinet. Indicates the cabinet type. NO

NO

No

None

NO

Yes

None

Indicates the cabinet number of the subrack.

YES

YES

No

None

Indicates the number of the subrack.

YES

YES

No

None

Indicates the type of NO the subrack.

YES

No

None

Indicates a brief description of the subrack, which can be the function, NO location, and some other information of the subrack.

NO

No

None

Indicates the type of power supply to the NO subrack.

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the cabinet where the EMU is located.

NO

Yes

None

YES

NO

No

None

Indicates the number of the subrack where the EMU is located.

YES

NO

No

None

Indicates the number of the slot where the EMU is located.

YES

NO

No

None

Indicates the cabinet number of the manager that manages the EMU. NO The manager of the EMU is usually a BBU or RRU.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the subrack number of the manager. The manager of the EMU is usually a BBU or RRU.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the number of the serial NO port to which the EMU is connected.

YES

No

LBFD-004012 / TDLBFD-004012

Indicates the communication address of the EMU, which is determined by the settings of the 4-bit dual in-line package (DIP) switch on the EMU. The communication address is used by the EMU to communicate with the main control and transmission board. The value of this parameter must NO be consistent with the actual settings of the DIP switch. The 4-bit DIP switch can be treated as a 4-bit binary number. The settings of ON and OFF are represented by 1 and 0 respectively. Convert the 4-bit number from binary to decimal, and then the decimal number is used as the value of this parameter. Indicates the lower limit of temperature. When the temperature is below the lower NO limit, an ALM-25650 Temperature Abnormal alarm is reported. Indicates the upper limit of temperature. When the temperature exceeds the upper NO limit, an ALM-25650 Temperature Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the lower limit of humidity. When the humidity is below the lower NO limit, an ALM-25651 Humidity Abnormal alarm is reported. Indicates the upper limit of humidity. When the humidity exceeds the upper NO limit, an ALM-25651 Humidity Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

Indicates whether to allow the report of a dedicated analog alarm. If the shield NO flag for an analog alarm is enabled, the analog alarm cannot be reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates whether to allow the report of a dedicated Boolean alarm. If the shield NO flag for a Boolean alarm is enabled, the Boolean alarm cannot be reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the current temperature NO of the environment. Indicates the NO ambient humidity. Indicates the -48 V input voltage from NO the power supply cabinet.

NO NO

Yes Yes

LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012

NO

Yes

Indicates the current value measured by the NO external sensor that is connected to analog port 1. Indicates the current value measured by the NO external sensor that is connected to analog port 2. Indicates the current value measured by the NO external sensor that is connected to analog port 3. Indicates the current value measured by the NO external sensor that is connected to analog port 4.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet. Indicates the description about the services and functions provided by the board or the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the cabinet where the FMU is located.

NO

Yes

None

YES

NO

No

None

Indicates the number of the subrack where the FMU is located.

YES

NO

No

None

Indicates the number of the slot where the FMU is located.

YES

NO

No

None

Indicates the cabinet number of the manager. The manager of the FMU is usually a BBU or RRU.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the subrack number of the manager. The manager of the FMU is usually a BBU or RRU.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the number of the serial NO port where the FMU is connected.

YES

No

LBFD-004012 / TDLBFD-004012

Indicates the communication address of the FMU. The FMU communicates with NO the main control and transmission board by using this communication address.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates whether to allow the report of a dedicated Boolean alarm. If the shield NO flag for a Boolean alarm is enabled, the Boolean alarm cannot be reported. Indicates the ratio of the current rotation speed of the fan to NO its maximum rotation speed. Indicates the temperature at the NO air outlet of the FMU. Indicates the temperature at the NO air inlet of the FMU. Indicates the average rotation NO speed of the fan per minute. Indicates the switch of smart temperature control. When the smart temperature control is enabled, the rotation speed of the fan is adjusted by the FMU according to the temperature control NO parameters delivered by the BBU. When the smart temperature control is disabled, the rotation speed of the fan is adjusted by the FMU automatically according to the temperature.

NO

No

None

NO

Yes

LBFD-004012 / TDLBFD-004012

NO

Yes

LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012

NO

Yes

NO

Yes

NO

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the cabinet where the TCU is located.

NO

Yes

None

YES

NO

No

None

Indicates the number of the subrack where the TCU is located.

YES

NO

No

None

Indicates the number of the slot where the TCU is located.

YES

NO

No

None

Indicates the cabinet number of the manager. The manager of the TCU is usually a BBU or RRU.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the subrack number of the manager. The manager of the TCU is usually a BBU or RRU.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the number of the serial NO port where the TCU is connected.

YES

No

LBFD-004012 / TDLBFD-004012

Indicates the communication address of the TCU. The TCU communicates with NO the main control and transmission board by using this communication address.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the lower threshold of the temperature. If the cabinet air outlet temperature is lower than the value, the NO ALM-25655 Cabinet Air Outlet Temperature Unacceptable is reported. Indicates the upper threshold of the temperature. If the cabinet air outlet temperature is higher than the NO value, the ALM25655 Cabinet Air Outlet Temperature Unacceptable is reported. Indicates whether to allow the report of a dedicated Boolean alarm. If the shield NO flag for a Boolean alarm is enabled, the Boolean alarm cannot be reported. Indicates the device type of the TCU. Indicates the temperature at the air inlet of the TCU. Indicates the temperature at the air outlet of the TCU. Indicates the temperature inside the TCU. Indicates the average rotation speed of the inner circulation fan per minute. Indicates the average rotation speed of the outer circulation fan per minute. NO NO

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

None

NO NO

Yes Yes

None LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the current heating power of the TCU. If this parameter is displayed as 0, the TCU is not heating the cabinet. If this parameter is not displayed as 0, the NO TCU is heating the cabinet. If this parameter is displayed as NULL, the TCU used for heating does not exist or is not supported. Indicates the software version of the TCU. Indicates the PCB version of the TCU. Indicates the erasable programmable logic device (EPLD) version of the TCU. Indicates the compiling time of the software program in the TCU. Indicates the version description of the TCU. Indicates the manufacturing date of the TCU. NO NO

NO

Yes

None

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the manufacturer of the NO TCU.

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet. Indicates the description about the services and functions provided by the board or the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the YES cabinet where the TCU is located. Indicates the number of the subrack where the TCU is located. Indicates the number of the slot where the TCU is located. YES

NO

Yes

None

NO

No

None

NO

No

None

YES

NO

No

None

Indicates the threshold of the low NO temperature state. Indicates the threshold of the high temperature state.

NO

No

LBFD-004012 / TDLBFD-004012

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the expected lowest temperature at the air outlet.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the tolerable error value NO of temperature control. Indicates the difference between the temperature at the air inlet and that NO of the environment at the normal temperature. Indicates the difference between the temperature at the air outlet and NO that of the air inlet at the normal temperature. Indicates the difference between the temperature at the air outlet and NO that of the environment at the high temperature. Indicates the number of the cabinet where the PMU is located.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

YES

NO

No

None

Indicates the number of the subrack where the PMU is located.

YES

NO

No

None

Indicates the number of the slot where the PMU is located. Indicates the cabinet number of the manager. The manager of the PMU is usually a BBU or RRU.

YES

NO

No

None

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the subrack number of the manager. The manager of the PMU is usually a BBU or RRU.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the number of the serial NO port where the PMU is connected.

YES

No

LBFD-004012 / TDLBFD-004012

Indicates the communication address of the PMU, which is determined by the settings of the 4-bit dual in-line package (DIP) switch on the PMU. The communication address is used by the PMU to communicate with the main control and transmission board. The value of this parameter must NO be consistent with the actual settings of the DIP switch. The 4-bit DIP switch can be treated as a 4-bit binary number. The settings of ON and OFF are represented by 1 and 0 respectively. Convert the 4-bit number from binary to decimal, and then the decimal number is used as the value of this parameter.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the type of the power system NO for the PMU.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the lower threshold of AC input voltage. When the AC input voltage is lower than the NO value, an ALM25622 Mains Input Abnormal alarm is reported. Indicates the higher threshold of AC input voltage. When the AC input voltage is higher than the NO value, an ALM25622 Mains Input Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the lower threshold of the DC voltage. When the output voltage of the busbar is lower NO than the value, an ALM-25621 DC Output Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the upper threshold of the DC voltage. When the output voltage of the busbar is higher NO than the value, an ALM-25621 DC Output Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the flag for power-off against low voltage, which determines whether NO the load is powered off in the case of low voltage.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the load voltage below which the load is powered off automatically NO when load power-off against low voltage is enabled.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the lower threshold of the cabinet temperature. If the cabinet temperature is lower than the NO value, an ALM25652 Cabinet Temperature Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the upper threshold of the cabinet temperature. If the cabinet temperature is higher than the NO value, an ALM25652 Cabinet Temperature Abnormal alarm is reported. Indicates the lower threshold of the cabinet humidity. If the cabinet humidity is lower than the NO value, an ALM25653 Cabinet Humidity Abnormal alarm is reported. Indicates the upper threshold of the cabinet humidity. If the cabinet humidity is higher than the NO value, an ALM25653 Cabinet Humidity Abnormal alarm is reported.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

None

NO

No

None

Indicates whether to allow the report of a dedicated analog alarm. If the shield NO flag for an analog alarm is enabled, the analog alarm cannot be reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates whether to allow the report of a dedicated Boolean alarm. If the shield NO flag for a Boolean alarm is enabled, the Boolean alarm cannot be reported.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the current AC voltage, that is, the input NO mains voltage to the rectifier. Indicates the DC output voltage of the busbar. Indicates the total load current. Indicates the current cabinet temperature of the cabinet. Indicates the ambient humidity of the cabinet. NO NO

NO

Yes

LBFD-004012 / TDLBFD-004012

NO NO

Yes Yes

LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012 LBFD-004012 / TDLBFD-004012

NO

NO

Yes

NO

NO

Yes

Indicates the poweron status of the secondary load. The secondary load can be set to automatically powered off in the following modes: HighTemperaturePo werOff(High NO temperature power off), LowTemperaturePo werOff(Low temperature power off), and LowVoltagePowerO ff(Low voltage power off).

NO

Yes

LBFD-004012 / TDLBFD-004012

Indicates the charging or discharging status of batteries. Boost charge is used to quickly recover the capacity of the battery. During the boost charge, the charging voltage is relatively high. After the battery is discharged, generally, the system automatically starts boost-charge on the NO battery. Floating charge is used to compensate for the power loss of the battery due to selfdischarge and to keep the capacity of the battery. It can also recover the battery capacity. During the floating charge, the charging voltage is relatively low. Force boost charge is an enhanced mode of the boost charge. Indicates the charging or NO discharging current of batteries. Indicates whether the batteries that are being charged are in the current limiting status.

NO

Yes

LBFD-004012 / TDLBFD-004012

NO

Yes

LBFD-004012 / TDLBFD-004012

NO

NO

Yes

LBFD-004012 / TDLBFD-004012

Indicates the poweron/power-off status of the battery. The battery can be disconnected manually or NO disconnected automatically for protection purpose based on different situations.

NO

Yes

LBFD-004012 / TDLBFD-004012

Indicates the remaining capacity of the battery by displaying the percentage of the current capacity to the total capacity.

NO

NO

Yes

LBFD-004012 / TDLBFD-004012

Indicates the current temperature NO of the battery.

NO

Yes

LBFD-004012 / TDLBFD-004012

Indicates the phase NO of the battery test.

NO

Yes

None

Indicates the total current of the NO photovoltaic array of the PMU. Indicates the current of the diesel generator which is NO managed by the PMU. Indicates the temperature of auxiliary battery cabinet which is connected to the PMU.

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the software version of NO the PMU. Indicates the PCB NO version of the PMU.

NO NO

Yes Yes

None None

Indicates the erasable programmable logic NO device version of the PMU. Indicate the software compiling NO time of the PMU. Indicates the version description NO of the PMU. Indicates the manufacturing date NO of the PMU.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the manufacturer of the NO PMU.

NO

Yes

None

Indicates the PSU intelligent shutdown NO capability of the PMU.

NO

Yes

None

Indicates the status of the PSU NO intelligent shutdown switch of the PMU.

NO

Yes

None

Indicates the execution result of the setting of the PSU intelligent shutdown switch.

NO

NO

Yes

None

Indicates the remaining NO discharging time of a battery. Indicates the accumulated charging time of a battery, including floating charging time and equalized charging time.

NO

Yes

None

NO

NO

Yes

None

Indicates the accumulated sleeping time of a battery. Battery NO sleeping effectively prolongs the battery lifespan. Indicates the battery intelligent management NO capability of the PMU. Indicates the battery intelligent NO management mode of the PMU.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the cabinet where the YES PMU managing the diesel generator is located.

NO

Yes

None

NO

No

None

Indicates the number of the subrack where the YES PMU managing the diesel generator is located.

NO

No

None

Indicates the number of the slot where the PMU YES managing the diesel generator is located.

NO

No

None

Indicates whether intelligent control of the diesel generator is enabled. When intelligent control is enabled, the PMU automatically controls the diesel NO generator according to the preset parameters, thus reducing the operation cost of the diesel generator. Indicates the maximum rated output power of the diesel generator. It should be configured NO according to the rated output power printed on the name plate of the diesel generator. Indicates the oil level of the diesel NO generator. Indicates the current of the diesel NO generator. Indicates the total running time of the NO diesel generator. Indicates the number of the cabinet where the YES PMU managing the battery is located.

NO

No

None

NO

No

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

No

None

Indicates the number of the subrack where the YES PMU managing the battery is located.

NO

No

None

Indicates the number of the slot where the PMU managing the battery is located.

YES

NO

No

None

Indicates the installation type of battery. This parameter can be set to INNER or OUTER. The value INNER indicates that batteries are installed in a power cabinet. The value OUTER indicates that batteries are installed in a standalone battery cabinet. For lithium batteries, this parameter is set to NO INNER. For leadacid batteries, this parameter can be set to either INNER or OUTER, depending on the type of power cabinet. If the power cabinet is APM30 of version 301 (silkscreen: APM30) or 302 (silkscreen: APM30H), this parameter is set as required. If the power cabinet is not APM30 of version

NO

No

None

Indicates the scheduled boost charging interval. Batteries are boostcharged at this interval (in the unit of day), which keeps the batteries NO fully charged. This parameter is configured according to the instructions provided by manufacturers.

NO

No

None

Indicates the boost charging voltage. Boost charge is used to quickly recover the capacity of batteries. During the boost charge, the charging voltage is relatively high. After the batteries are discharged, the NO system automatically starts boost charge on the batteries. This parameter is configured according to the instructions provided by manufacturers.

NO

No

None

Indicates the capacity of battery 1. This parameter should be set according to the NO actual situation. Incorrect configuration may reduce the life span of the battery.

NO

No

None

Indicates the battery charging current limiting coefficient. Charging coefficient x Storage capacity = Maximum charging current. When the charging current is not smaller than the maximum charging NO current plus 5 A, an ALM-25625 Battery Current Abnormal alarm is reported. This parameter is configured according to the instructions provided by manufacturers.

NO

No

None

Indicates the floating charging voltage. Floating charge is used to compensate for the power loss of the batteries due to selfdischarge. The floating charging NO voltage is lower than the boost charging voltage. This parameter is configured according to the instructions provided by manufacturers.

NO

No

None

Indicates whether to enable battery disconnection NO against high temperature.

NO

No

None

Indicates the temperature above which the battery is powered off NO automatically under the condition that HtempShutdownFlg is enabled.

NO

No

None

Indicates whether to enable battery NO power-off against low voltage.

NO

No

None

Indicates the voltage below which the battery is powered off NO automatically under the condition that LvolShutdownFlg is enabled.

NO

No

None

Indicates the increased or reduced charging voltage of every battery when the ambient temperature is 1 degree Celsius higher or lower than NO the standard temperature specified by manufacturers. This parameter should be set according to the instructions provided by manufacturers.

NO

No

None

Indicates the lower limit of temperature. When the battery temperature is below the lower NO limit, an ALM-25650 Environmental Temperature Abnormal alarm is reported.

NO

No

None

Indicates the upper limit of temperature. When the battery temperature exceeds the upper NO limit, an ALM-25650 Environmental Temperature Abnormal alarm is reported.

NO

No

None

Indicates the number of battery groups.

NO

NO

No

None

Indicates the type of NO the battery.

NO

No

None

Indicates the number of times that the battery is powered off. Indicates the number of times that the battery is charged in half an hour.

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the number of times that the battery is charged when the battery is charged NO for more than half an hour and less than one hour or for one hour. Indicates the number of times that the battery is charged when the battery is charged NO for more than one hour and less than two hours or for two hours. Indicates the number of times that the battery is charged when the battery is charged NO for more than two hours and less than three hours or for three hours. Indicates the number of times that the battery is charged when the battery is charged NO for more than three hours and less than four hours or for four hours.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the number of times that the battery is charged when the battery is charged NO for more than four hours and less than five hours or for five hours. Indicates the number of times that the battery is charged when the battery is charged NO for more than five hours and less than six hours or for six hours. Indicates the number of times that the battery is charged when the battery is charged NO for more than six hours and less than seven hours or for seven hours. Indicates the number of times that the battery is charged when the battery is charged NO for more than seven hours and less than eight hours or for eight hours. Indicates the number of times that the battery is charged in more than eight hours. Indicates the number of times that the battery is discharged in half an hour.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the number of times that the battery is discharged when the battery is NO discharged for more than half an hour and less than one hour or for one hour. Indicates the number of times that the battery is discharged when the battery is NO discharged for more than one hour and less than two hours or for two hours. Indicates the number of times that the battery is discharged when the battery is NO discharged for more than two hours and less than three hours or for three hours. Indicates the number of times that the battery is discharged when the battery is NO discharged for more than three hours and less than four hours or for four hours. Indicates the number of times that the battery is discharged when the battery is NO discharged for more than four hours and less than five hours or for five hours.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the number of times that the battery is discharged when the battery is NO discharged for more than five hours and less than six hours or for six hours. Indicates the number of times that the battery is discharged when the battery is NO discharged for more than six hours and less than seven hours or for seven hours. Indicates the number of times that the battery is discharged when the battery is NO discharged for more than seven hours and less than eight hours or for eight hours. Indicates the number of times that the battery is NO discharged in more than eight hours. Indicates the date when the battery is installed. The scheduled tests for NO the battery are dependent on the installation date.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the capacity of battery 2. This parameter should be set according to the NO actual situation. Incorrect configuration may reduce the life span of the battery.

NO

No

None

Indicates the number of the cabinet where the YES PMU managing the battery is located. Indicates the number of the subrack where the YES PMU managing the battery is located. Indicates the number of the slot where the PMU managing the battery is located.

NO

No

None

NO

No

None

YES

NO

No

None

Indicates the duration of discharging the battery with the current of 0.05C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.05C10 indicates NO that the battery is discharged with the current of 0.05 x norminal capacity of the battery. For example, if the battery capacity is 100 AH, 0.05C10 indicates that the battery is discharged with the current of 5 AH. Indicates the duration of discharging the battery with the current of 0.1C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.1C10 indicates NO that the battery is discharged with the current of 0.1 x norminal capacity of the battery. For example, if the battery capacity is 100 AH, 0.1C10 indicates that the battery is discharged with the current of 10 AH.

NO

No

None

NO

No

None

Indicates the duration of discharging the battery with the current of 0.2C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.2C10 indicates NO that the battery is discharged with the current of 0.2 x norminal capacity of the battery. For example, if the battery capacity is 100 AH, 0.2C10 indicates that the battery is discharged with the current of 20 AH. Indicates the duration of discharging the battery with the current of 0.3C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.3C10 indicates NO that the battery is discharged with the current of 0.3 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.3C10 indicates that the battery is discharged with the current of 30 AH.

NO

No

None

NO

No

None

Indicates the duration of discharging the battery with the current of 0.4C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.4C10 indicates NO that the battery is discharged with the current of 0.4 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.4C10 indicates that the battery is discharged with the current of 40 AH. Indicates the duration of discharging the battery with the current x 0.5C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.5C10 indicates NO that the battery is discharged with the current of 0.5 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.5C10 indicates that the battery is discharged with the current of 50 AH.

NO

No

None

NO

No

None

Indicates the duration of discharging the battery with the current of 0.6C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.6C10 indicates NO that the battery is discharged with the current of 0.6 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.6C10 indicates that the battery is discharged with the current of 60 AH. Indicates the duration of discharging the battery with the current of 0.7C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.7C10 indicates NO that the battery is discharged with the current of 0.7 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.7C10 indicates that the battery is discharged with the current of 70 AH.

NO

No

None

NO

No

None

Indicates the duration of discharging the battery with the current of 0.8C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.8C10 indicates NO that the battery is discharged with the current of 0.8 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.8C10 indicates that the battery is discharged with the current of 80 AH. Indicates the duration of discharging the battery with the current of 0.9C10 to the moment when the discharging voltage is terminated. C10 indicates the nominal capacity of the battery, and 0.9C10 indicates NO that the battery is discharged with the current of 0.9 x nominal capacity of the battery. For example, if the battery capacity is 100 AH, 0.9C10 indicates that the battery is discharged with the current of 90 AH.

NO

No

None

NO

No

None

Indicates the charging efficiency of batteries. The battery efficiency is a percentage of battery performance to the normal battery capacity. For NO example, a normal battery can supply power for 10 hours. If a battery can supply power for only eight hours, its battery efficiency is 80%. Indicates the end voltage of the discharging test.

NO

No

None

NO

NO

No

None

Indicates the quantity of battery in NO the battery group. Indicates the time limit of the discharging test.

NO

No

None

NO

NO

No

None

Indicates the time limit for the simplified discharging test. There are two types of discharging tests for a battery: a standard test and a NO simplified test. A standard test calculates the battery efficiency, and a simplified test judges only the quality of the battery. Indicates the end voltage of the simple discharging test.

NO

No

None

NO

NO

No

None

Indicates the test mode. It specifies whether to use the automatic test and which automatic test mode is used. There are four types of test modes: NOAUTOTEST (No Auto Test), PERIOD (Period Auto Test), POWERCUT (Power Off Auto Test), and PERIODPOWERC UT (Period and NO Power Off Auto Test). No Auto Test: indicates that the battery test is launched and controlled by the user. Period Auto Test: indicates that the battery test is launched automatically by the system as scheduled. Power Off Auto Test: indicates that the battery test is launched

NO

No

None

Indicates the time limit of the scheduled discharging test.

NO

NO

No

None

Indicates the time limit for the discharging test delay when the power is off or the discharging test is launched automatically. The interval between two battery tests must be greater than this time limit. Otherwise, the execution of the STR BATTST command fails.

NO

NO

No

None

Indicates the type of the battery test. There are two types of battery tests: STANDARD(Stand ard Test) and SIMPLE(Simple Test). Standard Test is used to calculate the NO efficiency of the battery. Simple Test is used only to judge the quality of the battery, but not to calculate the efficiency of the battery. This test takes a short time. Indicates the test start date, which is in the format of YYYY/MM/DD.

NO

Yes

None

NO

NO

Yes

None

Indicates the end reason of the battery test.

NO

NO

Yes

None

Indicates the result NO of the battery test.

NO

Yes

None

Indicates the battery efficiency. The battery is normal NO when the result is between 80% and 100%. Indicates the continued discharge NO duration of the battery. Indicates the voltage of the NO battery when the discharge is ended. Indicates the average current in the process of the battery discharge. Indicates the accumulated discharged power (Ah) from the beginning of discharge. NO

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the current temperature NO of the battery. Indicates the number of the YES cabinet where the PSU is located. Indicates the number of the subrack where the PSU is located. YES

NO

Yes

None

NO

No

None

NO

No

None

Indicates the number of the slot where the PSU is located.

YES

NO

No

None

Indicates the running status of the PSU.

NO

NO

Yes

None

Indicates the manufacturing date NO of the PSU.

NO

Yes

None

Indicates the manufacturer of the NO PSU.

NO

Yes

None

Indicates the PCB NO version of the PSU. Indicates the erasable programmable logic NO device (EPLD) version of the PSU. Indicates the compiling time of the software program in the PSU.

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the cabinet number of the board where the YES output port is located. Indicates the subrack number of the board where the YES output port is located. Indicates the slot number of the board YES where the output port is located. Indicates the number of the YES output port. Indicates the name NO of the output port.

NO

Yes

None

NO

No

None

NO

No

None

NO

No

None

YES

No

None

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the enabled/disabled state of the output port.

NO

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the cabinet number of YES the board where the port is located. Indicates the subrack number of YES the board where the port is located. Indicates the slot number of the board YES where the port is located. Indicates the port YES number. Indicates the enabled/disabled state of the port. Alarms can be detected and NO reported through the port only when the state of the port is ON. Indicates the alarm ID bound to the alarm port. This parameter is NO reported as the ID of the alarm detected at the port.

YES

No

None

YES

No

None

YES

No

None

YES

No

None

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the alarm port types: analog alarm port and digital alarm port. An analog alarm port is used to monitor the external environment that changes continuously. The port is supported only by the EMU. A digital alarm port is NO used to monitor the external environment of which the change is indicated in Boolean or discrete values. It is contained in the EMU, PMU, TCU, FMU, RRU, and power boards. The SC48200 PMU does not support digital ports.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the alarm level. This parameter specifies whether alarms generated by the sensor over the port NO are in high or low voltage. The alarm level is set according to the type of external sensor.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the alarm upper limit. If the environment measurement value is greater than the alarm upper limit configured for the sensor, the alarm is reported. Environment measurement value = Measurement lower limit + (Measurement upper limit Measurement lower NO limit) x (Observed electric current or voltage - Output lower limit)/(Output upper limit - Output lower limit).Temperature is measured in the unit of degree Celsius, voltage is measured in the unit of volt, and current is measured in the unit of milliampere.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the alarm lower limit. If the environment measurement value is smaller than the alarm lower limit configured for the sensor, the alarm is reported. Environment measurement value = Measurement lower limit + (Measurement upper limit Measurement lower NO limit) x (Observed electric current or voltage - Output lower limit)/(Output upper limit - Output lower limit).Temperature is measured in the unit of degree Celsius, voltage is measured in the unit of volt, and current is measured in the unit of milliampere. Indicates the sensor type. The user can set the sensor type to current type or NO voltage type according to the actual external sensor.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the measurement upper limit of the analog port. The range is set based on the actual situations such as the temperature and humidity.Temperatu NO re is measured in the unit of degree Celsius, voltage is measured in the unit of volt, and current is measured in the unit of milliampere.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the measurement lower limit of the analog port. The range is set based on the actual situations such as the temperature and humidity.Temperatu NO re is measured in the unit of degree Celsius, voltage is measured in the unit of volt, and current is measured in the unit of milliampere.

NO

No

LBFD-004012 / TDLBFD-004012

Indicates the upper limit of the output signals from the analog port. For sensors of either the current type or NO voltage type, the upper limit should be set according to the specifications of the sensor. Indicates the lower limit of the output signals from the analog port. For sensors of either the current type or NO voltage type, the lower limit should be set according to the specifications of the sensor. Indicates the connection type supported by the NE.

NO

No

LBFD-004012 / TDLBFD-004012

NO

No

LBFD-004012 / TDLBFD-004012

NO

NO

No

None

Indicates the authentication mode NO of the SSL connection.

NO

No

None

Indicates the cabinet number of the AAU.

YES

YES

No

None

Indicates the subrack number of the AAU.

YES

YES

No

None

Indicates the slot YES number of the AAU.

YES

No

None

Indicates the AAU name.

NO

NO

No

None

Indicates the RRU type of the AAU.

NO

YES

No

None

Indicates the NO administrative state.

NO

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

The VSWR alarm post-processing switch. If the switch is set to ON when the VSWR is greater than the VSWR alarm postprocessing threshold, the TX channel is performed to shut down. If the switch is set to OFF, the RRU degrades power. When this switch is set to OFF, an RF NO module decreases the total TX power of the TX channel by 3 dB to minimize the impacts of high VSWR. Different scenarios are described as follows: 1. An RF module degrades its power by decreasing the TX power of carriers sharing TX channels by 3 dB. 2. In the scenario where two TX

NO

No

None

Indicates the VSWR alarm postprocessing threshold. If the VSWR alarm postprocessing switch is set to ON and the VSWR is greater than the threshold, post-processing is performed to shut down the TX channel. In this case, the TX channel cannot be open automatically after the VSWR is NO normal. The VSWR alarm postprocessing threshold must be greater than 2.0. Otherwise, the following will occur:a. Setting the ALMPROCTHRHL D parameter by MML commands fails.b. When the VSWR alarm postprocessing threshold is configured in the configuration files

NO

No

None

Indicates the VSWR alarm threshold. When the current VSWR is greater than the threshold, a VSWR Abnormal alarm is reported. It is recommended that the VSWR alarm threshold be set according to the VSWR required by the engineering quality to reduce the probability that the VSWR alarm is reported falsely. NO To stabilize the false alarm probability to 1%, 0.1%, and 0.01%, you need to set the VSWR alarm threshold to the following recommended values: When the VSWR required by the engineering quality is smaller than or equal to 1.4, the recommended thresholds are 1.8,

NO

No

None

Indicates the position of the RRU, RFU on the chain or NO ring. It is calculated from the start port one by one.

YES

No

None

Indicates the ID of the RRU or RFU chain/ring.

NO

YES

No

None

Indicates the position where the RRU or RFU is installed in the topology. The main NO chain/ring is the one connected to the optical port on the baseband processing board.

NO

No

None

Indicates the working mode of the RRU or RFU. MRFU, MRRU, and PRRU support both single-mode and multi-mode base NO stations. LRFU supports only LTE_FDD and LRRU supports LTE_TDD and LTE_FDD.

YES

No

None

Indicates the number of RX channels of the RRU or RFU. Indicates the number of TX channels of the RRU or RFU. Indicates the number of carriers on each RX channel. Indicates the number of carriers on each TX channel. Indicates the

NO

YES

No

None

NO

YES

No

None

NO

NO

Yes

None

NO

NO

Yes

None

minimum uplink frequency supported by the RRU. For example, if this parameter is NO set to 9250, the minimum uplink frequency of the RRU is 9250 x 0.1 MHz, which equals to 925 MHz.

NO

Yes

None

Indicates the maximum uplink frequency supported by the RRU. For example, if this parameter is set to 9450, the maximum uplink frequency of the RRU is 9450 x 0.1 MHz, which equals to 945 MHz. Indicates the minimum downlink frequency supported by the RRU. For example, this parameter is set to 9650, the minimum downlink frequency of the RRU is 9650 x 0.1 MHz, which equals to 965 MHz. Indicates the maximum downlink frequency supported by the RRU. For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz. Indicates the maximum output power per TX channel in the RRU/RFU. Indicates the UL channel gain. Indicates the bandwidth supported by each TX channel in the uplink.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the temperature of the NO PA. Indicates the current temperature NO of the RRU or RFU.

NO

Yes

None

NO

Yes

None

Indicates the RRU/RFU level on NO the trunk of the chain/ring. Indicates the serial number of the RRU NO or RFU.

NO

Yes

None

NO

Yes

None

Indicates the standards that are supported by the RRU or RFU.

NO

NO

Yes

None

Indicates the access direction of the service plane.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 (single carrier) of the RRU or RFU.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 NO (multiple carriers) of the RRU or RFU. Indicates the bandwidth supported by each TX channel in the downlink.

NO

Yes

None

NO

NO

Yes

None

Indicates the physical indicator of NO the RRU. Indicates the periodical report switch for the Bit Error Rate (BER) on the link. If the switch NO is set to ON, the result of BER test is reported periodically. Indicates the test time. When the test time is over, the system NO automatically stops the test and reports the test result. Indicates the interference check mode. POW_IQ_MODE indicates that both power and IQ data is collected. NO POW_MODE indicates that only power data is collected. IQ_MODE indicates that only IQ data is collected. Indicates the shortduration power NO statistics period.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the duration for a single NO collection of power statistics.

NO

Yes

None

Indicates the UL frequency. Indicates the bit error rate. Indicates the interference check sampling result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the set type.

NO

NO

Yes

None

Indicates the BER threshold. The BER NO threshold reflects the link quality.

NO

Yes

None

Indicates the Linerate.

NO

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the NO administrative state.

NO

Yes

None

NO

No

None

The VSWR alarm post-processing switch. If the switch is set to ON when the VSWR is greater than the VSWR alarm postprocessing threshold, the TX channel is performed to shut down. If the switch is set to OFF, the RRU degrades power. When this switch is set to OFF, an RF NO module decreases the total TX power of the TX channel by 3 dB to minimize the impacts of high VSWR. Different scenarios are described as follows: 1. An RF module degrades its power by decreasing the TX power of carriers sharing TX channels by 3 dB. 2. In the scenario where two TX

NO

No

None

Indicates the VSWR alarm postprocessing threshold. If the VSWR alarm postprocessing switch is set to ON and the VSWR is greater than the threshold, post-processing is performed to shut down the TX channel. In this case, the TX channel cannot be open automatically after the VSWR is NO normal. The VSWR alarm postprocessing threshold must be greater than 2.0. Otherwise, the following will occur:a. Setting the ALMPROCTHRHL D parameter by MML commands fails.b. When the VSWR alarm postprocessing threshold is configured in the configuration files

NO

No

None

Indicates the VSWR alarm threshold. When the current VSWR is greater than the threshold, a VSWR Abnormal alarm is reported. It is recommended that the VSWR alarm threshold be set according to the VSWR required by the engineering quality to reduce the probability that the VSWR alarm is reported falsely. NO To stabilize the false alarm probability to 1%, 0.1%, and 0.01%, you need to set the VSWR alarm threshold to the following recommended values: When the VSWR required by the engineering quality is smaller than or equal to 1.4, the recommended thresholds are 1.8,

NO

No

None

Indicates the position of the RRU, RFU on the chain or NO ring. It is calculated from the start port one by one.

YES

No

None

Indicates the ID of the RRU or RFU chain/ring.

NO

YES

No

None

Indicates the position where the RRU or RFU is installed in the topology. The main NO chain/ring is the one connected to the optical port on the baseband processing board.

NO

No

None

Indicates the working mode of the RRU or RFU. MRFU, MRRU, and PRRU support both single-mode and multi-mode base NO stations. LRFU supports only LTE_FDD and LRRU supports LTE_TDD and LTE_FDD.

YES

No

None

Indicates the number of RX channels of the RRU or RFU. Indicates the number of TX channels of the RRU or RFU. Indicates the number of carriers on each RX channel. Indicates the number of carriers on each TX channel. Indicates the

NO

YES

No

None

NO

YES

No

None

NO

NO

Yes

None

NO

NO

Yes

None

minimum uplink frequency supported by the RRU. For example, if this parameter is NO set to 9250, the minimum uplink frequency of the RRU is 9250 x 0.1 MHz, which equals to 925 MHz.

NO

Yes

None

Indicates the maximum uplink frequency supported by the RRU. For example, if this parameter is set to 9450, the maximum uplink frequency of the RRU is 9450 x 0.1 MHz, which equals to 945 MHz. Indicates the minimum downlink frequency supported by the RRU. For example, this parameter is set to 9650, the minimum downlink frequency of the RRU is 9650 x 0.1 MHz, which equals to 965 MHz. Indicates the maximum downlink frequency supported by the RRU. For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz. Indicates the maximum output power per TX channel in the RRU/RFU. Indicates the UL channel gain. Indicates the bandwidth supported by each TX channel in the uplink.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the temperature of the NO PA. Indicates the current temperature NO of the RRU or RFU.

NO

Yes

None

NO

Yes

None

Indicates the RRU/RFU level on NO the trunk of the chain/ring. Indicates the serial number of the RRU NO or RFU.

NO

Yes

None

NO

Yes

None

Indicates the standards that are supported by the RRU or RFU.

NO

NO

Yes

None

Indicates the access direction of the service plane.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 (single carrier) of the RRU or RFU.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 NO (multiple carriers) of the RRU or RFU. Indicates the bandwidth supported by each TX channel in the downlink.

NO

Yes

None

NO

NO

Yes

None

Indicates the physical indicator of NO the RRU. Indicates the periodical report switch for the Bit Error Rate (BER) on the link. If the switch NO is set to ON, the result of BER test is reported periodically. Indicates the test time. When the test time is over, the system NO automatically stops the test and reports the test result. Indicates the interference check mode. POW_IQ_MODE indicates that both power and IQ data is collected. NO POW_MODE indicates that only power data is collected. IQ_MODE indicates that only IQ data is collected. Indicates the shortduration power NO statistics period.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the duration for a single NO collection of power statistics.

NO

Yes

None

Indicates the UL frequency. Indicates the bit error rate. Indicates the interference check sampling result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the set type.

NO

NO

Yes

None

Indicates the BER threshold. The BER NO threshold reflects the link quality.

NO

Yes

None

Indicates the Linerate.

NO

NO

Yes

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet. Indicates the description about the services and functions provided by the board or the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the YES cabinet where the RFU is located. Indicates the number of the subrack where the RFU is located. YES

NO

Yes

None

NO

No

None

YES

No

None

Indicates the slot YES number of the RFU.

YES

No

None

Indicates the type of NO the RFU.

YES

No

None

Indicates the NO administrative state.

NO

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

The VSWR alarm post-processing switch. If the switch is set to ON when the VSWR is greater than the VSWR alarm postprocessing threshold, the TX channel is performed to shut down. If the switch is set to OFF, the RRU degrades power. When this switch is set to OFF, an RF NO module decreases the total TX power of the TX channel by 3 dB to minimize the impacts of high VSWR. Different scenarios are described as follows: 1. An RF module degrades its power by decreasing the TX power of carriers sharing TX channels by 3 dB. 2. In the scenario where two TX

NO

No

None

Indicates the VSWR alarm postprocessing threshold. If the VSWR alarm postprocessing switch is set to ON and the VSWR is greater than the threshold, post-processing is performed to shut down the TX channel. In this case, the TX channel cannot be open automatically after the VSWR is NO normal. The VSWR alarm postprocessing threshold must be greater than 2.0. Otherwise, the following will occur:a. Setting the ALMPROCTHRHL D parameter by MML commands fails.b. When the VSWR alarm postprocessing threshold is configured in the configuration files

NO

No

None

Indicates the VSWR alarm threshold. When the current VSWR is greater than the threshold, a VSWR Abnormal alarm is reported. It is recommended that the VSWR alarm threshold be set according to the VSWR required by the engineering quality to reduce the probability that the VSWR alarm is reported falsely. NO To stabilize the false alarm probability to 1%, 0.1%, and 0.01%, you need to set the VSWR alarm threshold to the following recommended values: When the VSWR required by the engineering quality is smaller than or equal to 1.4, the recommended thresholds are 1.8,

NO

No

None

Indicates the position of the RRU, RFU on the chain or NO ring. It is calculated from the start port one by one.

YES

No

None

Indicates the ID of the RRU or RFU chain/ring.

NO

YES

No

None

Indicates the position where the RRU or RFU is installed in the topology. The main NO chain/ring is the one connected to the optical port on the baseband processing board.

NO

No

None

Indicates the working mode of the RRU or RFU. MRFU, MRRU, and PRRU support both single-mode and multi-mode base NO stations. LRFU supports only LTE_FDD and LRRU supports LTE_TDD and LTE_FDD.

YES

No

None

Indicates the number of RX channels of the RRU or RFU. Indicates the number of TX channels of the RRU or RFU. Indicates the number of carriers on each RX channel. Indicates the number of carriers on each TX channel. Indicates the

NO

YES

No

None

NO

YES

No

None

NO

NO

Yes

None

NO

NO

Yes

None

minimum uplink frequency supported by the RRU. For example, if this parameter is NO set to 9250, the minimum uplink frequency of the RRU is 9250 x 0.1 MHz, which equals to 925 MHz.

NO

Yes

None

Indicates the maximum uplink frequency supported by the RRU. For example, if this parameter is set to 9450, the maximum uplink frequency of the RRU is 9450 x 0.1 MHz, which equals to 945 MHz. Indicates the minimum downlink frequency supported by the RRU. For example, this parameter is set to 9650, the minimum downlink frequency of the RRU is 9650 x 0.1 MHz, which equals to 965 MHz. Indicates the maximum downlink frequency supported by the RRU. For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz. Indicates the maximum output power per TX channel in the RRU/RFU. Indicates the UL channel gain. Indicates the bandwidth supported by each TX channel in the uplink.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the temperature of the NO PA. Indicates the current temperature NO of the RRU or RFU.

NO

Yes

None

NO

Yes

None

Indicates the RRU/RFU level on NO the trunk of the chain/ring. Indicates the serial number of the RRU NO or RFU.

NO

Yes

None

NO

Yes

None

Indicates the standards that are supported by the RRU or RFU.

NO

NO

Yes

None

Indicates the access direction of the service plane.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 (single carrier) of the RRU or RFU.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 NO (multiple carriers) of the RRU or RFU. Indicates the bandwidth supported by each TX channel in the downlink.

NO

Yes

None

NO

NO

Yes

None

Indicates the physical indicator of NO the RRU. Indicates the periodical report switch for the Bit Error Rate (BER) on the link. If the switch NO is set to ON, the result of BER test is reported periodically. Indicates the test time. When the test time is over, the system NO automatically stops the test and reports the test result. Indicates the interference check mode. POW_IQ_MODE indicates that both power and IQ data is collected. NO POW_MODE indicates that only power data is collected. IQ_MODE indicates that only IQ data is collected. Indicates the shortduration power NO statistics period.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the duration for a single NO collection of power statistics.

NO

Yes

None

Indicates the UL frequency. Indicates the bit error rate. Indicates the interference check sampling result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the set type.

NO

NO

Yes

None

Indicates the BER threshold. The BER NO threshold reflects the link quality.

NO

Yes

None

Indicates the Linerate.

NO

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the number of the cabinet where the RRU is located.

NO

Yes

None

YES

NO

No

None

Indicates the number of the subrack where the RRU is located.

YES

YES

No

None

Indicates the number of the slot where the RRU is located.

YES

NO

No

None

Indicates the RRU name.

NO

NO

No

None

Indicates the type of NO the RRU.

YES

No

None

Indicates the test type. Indicates the test time.

NO NO

NO NO

Yes Yes

None None

Indicates the difference of the RSSI voltage threshold between full power and no power during the NO PIMOFFLINE test. If the difference is greater than this threshold, intermodulation interference exists. Indicates the number of the antenna port. Indicates the test result. Indicates the value of the RTWP. Indicates the difference of the RTWP. Indicates the maximum value of the RTWP. NO

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the NO administrative state.

NO

No

None

Indicates the alarm status. For details about the definition NO of Alarm Status, see ITU-T X.731.

NO

Yes

None

Indicates the operational state of the board, which can be set to Enabled or Disabled. Enabled indicates that NO services can be carried on the board. Disabled indicates that no service can be carried on the board.

NO

Yes

None

Indicates the physical operation status of the board, which can be Uninstalled, Starting up, Normal, Inconsistent, Unconfigured, Power off, Fault, Communication lost, In test, or the combination of various states. For NO example, if a board is not configured and fails to communicate with the main control and transmission board, the physical operation status of the board is Unconfigured, Communication lost.

NO

Yes

None

Indicates the Elabel, a text file with a maximum of 2 KB. It is used to record the manufacturing NO information about equipment such as the board, subboard, or optical module. Indicates the type of NO the board. Indicates the bar code of the board or NO the cabinet.

NO

Yes

None

NO NO

Yes Yes

None None

Indicates the description about the services and functions provided by the board or the cabinet.

NO

NO

Yes

None

Indicates the manufacturing date NO of the board or the cabinet. Indicates the manufacturer of the NO board or the cabinet. Indicates the issue number of the NO board.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the type of NO a board.

NO

Yes

None

Indicates the CPU NO or DSP usage. Indicates the object NO number of a board.

NO NO

Yes Yes

None None

Indicates the object type of a board, NO which is CPU or DSP.

NO

Yes

None

Indicates the temperature of a NO board. Indicates the temperature of the NO power amplifier. Indicates the result NO of the operation. Indicates the service type of the CPU or DSP of the board. The service types of the DSP consist of uplink NO and downlink services. The service types of the CPU consist of Master and Slave.

NO

Yes

None

NO NO

Yes Yes

None None

NO

Yes

None

Indicates the type of NO the device.

NO

Yes

None

The VSWR alarm post-processing switch. If the switch is set to ON when the VSWR is greater than the VSWR alarm postprocessing threshold, the TX channel is performed to shut down. If the switch is set to OFF, the RRU degrades power. When this switch is set to OFF, an RF NO module decreases the total TX power of the TX channel by 3 dB to minimize the impacts of high VSWR. Different scenarios are described as follows: 1. An RF module degrades its power by decreasing the TX power of carriers sharing TX channels by 3 dB. 2. In the scenario where two TX

NO

No

None

Indicates the VSWR alarm postprocessing threshold. If the VSWR alarm postprocessing switch is set to ON and the VSWR is greater than the threshold, post-processing is performed to shut down the TX channel. In this case, the TX channel cannot be open automatically after the VSWR is NO normal. The VSWR alarm postprocessing threshold must be greater than 2.0. Otherwise, the following will occur:a. Setting the ALMPROCTHRHL D parameter by MML commands fails.b. When the VSWR alarm postprocessing threshold is configured in the configuration files

NO

No

None

Indicates the VSWR alarm threshold. When the current VSWR is greater than the threshold, a VSWR Abnormal alarm is reported. It is recommended that the VSWR alarm threshold be set according to the VSWR required by the engineering quality to reduce the probability that the VSWR alarm is reported falsely. NO To stabilize the false alarm probability to 1%, 0.1%, and 0.01%, you need to set the VSWR alarm threshold to the following recommended values: When the VSWR required by the engineering quality is smaller than or equal to 1.4, the recommended thresholds are 1.8,

NO

No

None

Indicates the position of the RRU, RFU on the chain or NO ring. It is calculated from the start port one by one.

YES

No

None

Indicates the ID of the RRU or RFU chain/ring.

NO

YES

No

None

Indicates the position where the RRU or RFU is installed in the topology. The main NO chain/ring is the one connected to the optical port on the baseband processing board.

NO

No

None

Indicates the working mode of the RRU or RFU. MRFU, MRRU, and PRRU support both single-mode and multi-mode base NO stations. LRFU supports only LTE_FDD and LRRU supports LTE_TDD and LTE_FDD.

YES

No

None

Indicates the number of RX channels of the RRU or RFU. Indicates the number of TX channels of the RRU or RFU. Indicates the number of carriers on each RX channel. Indicates the number of carriers on each TX channel. Indicates the

NO

YES

No

None

NO

YES

No

None

NO

NO

Yes

None

NO

NO

Yes

None

minimum uplink frequency supported by the RRU. For example, if this parameter is NO set to 9250, the minimum uplink frequency of the RRU is 9250 x 0.1 MHz, which equals to 925 MHz.

NO

Yes

None

Indicates the maximum uplink frequency supported by the RRU. For example, if this parameter is set to 9450, the maximum uplink frequency of the RRU is 9450 x 0.1 MHz, which equals to 945 MHz. Indicates the minimum downlink frequency supported by the RRU. For example, this parameter is set to 9650, the minimum downlink frequency of the RRU is 9650 x 0.1 MHz, which equals to 965 MHz. Indicates the maximum downlink frequency supported by the RRU. For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz. Indicates the maximum output power per TX channel in the RRU/RFU. Indicates the UL channel gain. Indicates the bandwidth supported by each TX channel in the uplink.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the temperature of the NO PA. Indicates the current temperature NO of the RRU or RFU.

NO

Yes

None

NO

Yes

None

Indicates the RRU/RFU level on NO the trunk of the chain/ring. Indicates the serial number of the RRU NO or RFU.

NO

Yes

None

NO

Yes

None

Indicates the standards that are supported by the RRU or RFU.

NO

NO

Yes

None

Indicates the access direction of the service plane.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 (single carrier) of the RRU or RFU.

NO

NO

Yes

None

Indicates the maximum output power of TX unit 0 NO (multiple carriers) of the RRU or RFU. Indicates the bandwidth supported by each TX channel in the downlink.

NO

Yes

None

NO

NO

Yes

None

Indicates the physical indicator of NO the RRU. Indicates the periodical report switch for the Bit Error Rate (BER) on the link. If the switch NO is set to ON, the result of BER test is reported periodically. Indicates the test time. When the test time is over, the system NO automatically stops the test and reports the test result. Indicates the interference check mode. POW_IQ_MODE indicates that both power and IQ data is collected. NO POW_MODE indicates that only power data is collected. IQ_MODE indicates that only IQ data is collected. Indicates the shortduration power NO statistics period.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the duration for a single NO collection of power statistics.

NO

Yes

None

Indicates the UL frequency. Indicates the bit error rate. Indicates the interference check sampling result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

Indicates the set type.

NO

NO

Yes

None

Indicates the BER threshold. The BER NO threshold reflects the link quality.

NO

Yes

None

Indicates the Linerate.

NO

NO

Yes

None

Indicates the Office name of the BS. Indicates the software version of the board. Indicates the hardware version of the board. Indicates the BootROM version of the board. Indicates the test time. Indicates the test result.

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

NO NO

NO NO

Yes Yes

None None

NO

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [10562-10838] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9662-9938] Offset: 0 Special Frequencies Channel Number: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Offset: 1850.1 Band3: Common Frequencies Channel Number: [1162-1513] Offset: 1575 Special

NO

Yes

None

The downlink and uplink frequencies of the local cell must stay within the same frequency band. Frequency(MHZ) = (Frequency Channel Number / 5) + Offset Band1: Common Frequencies Channel Number: [9612-9888] Offset: 0 Special Frequencies Channel Number: NO none Offset: 0 Band2: Common Frequencies Channel Number: [9262-9538] Offset: 0 Special Frequencies Channel Number: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Offset: 1850.1 Band3: Common Frequencies Channel Number: [937-1288] Offset: 1525 Special Indicates the ID of the RRU chain. It uniquely identifies a YES chain within a base station.

NO

Yes

None

YES

No

None

Indicates the type of NO the topology.

YES

No

None

Indicates the backup mode of the RRU chain/ring. There are two modes: cold backup and hot backup. Cold backup indicates that when the link on one end of the chain/ring fails, the service is disrupted for a short period of time, and then re-established on the other end of the chain/ring. Hot backup indicates NO that when the link on one end of the chain/ring fails, the service is taken over by the other end of the chain/ring immediately. There is only one RRU on the chain/ring in hot backup mode.In the RRUCHAIN MO, if TT is set to RING and BM is set to HOT, the head CPRI port and the tail CPRI port of the

NO

No

None

Indicates the cabinet number of the board where the NO head CPRI port is located.

NO

No

None

Indicates the subrack number of the board where the NO head CPRI port is located.

NO

No

None

Indicates the slot number of the board where the head NO CPRI port is located.

YES

No

None

Indicates the number of the head NO CPRI port.

YES

No

None

Indicates the cabinet number of the board where the NO tail CPRI port is located.

NO

No

None

Indicates the subrack number of the board where the NO tail CPRI port is located.

NO

No

None

Indicates the slot number of the board NO where the tail CPRI port is located.

YES

No

None

Indicates the number of the tail CPRI port.

NO

YES

No

None

Indicates the breakpoint position 1 on the chain/ring. When this NO parameter is set to 255, the breakpoint is disabled.

NO

No

None

Indicates the breakpoint position 2 on the chain/ring. When this NO parameter is set to 255, the breakpoint is disabled.

NO

No

None

Indicates the access type of the RRU. When AccessType is set to the local port, the LBBP is connected to the RRU/RFU through the CPRI port. When AccessType is set NO to the peer port, the peer LBBP is directly connected to the RRU/RFU, and the local LBBP is connected to the peer LBBP through the IDX2 port on the backplane.

NO

No

None

Indicates the userdefined rate. The value AUTO indicates the the auto negotiation mode is adopted. The value 1.25 indicates that the CPRI rate is 1.25 Gbit/s. The value 2.5 indicates that NO the CPRI rate is 2.5 Gbit/s. The value 4.9 indicates that the CPRI rate is 4.9 Gbit/s. The value 6.1 indicates that the CPRI rate is 6.1 Gbit/s. The value 9.8 indicates that the CPRI rate is 9.8 Gbit/s. Indicates the level NO of the RRU chain. Indicates the number of RRUs NO carried on the RRU chain/ring.

NO

No

None

NO

Yes

None

NO

Yes

None

Indicates the cabinet number of the RRU where the YES RX channel of the RRU is located.

NO

No

None

Indicates the subrack number of the RRU where the YES RX channel of the RRU is located.

YES

No

None

Indicates the slot number of the RRU where the RX YES channel of the RRU is located.

NO

No

None

Indicates the number of the RX YES channel of the RRU. Indicates the logical switch of the RX channel of the RRU, which is set to ON by default. The NO switch can be set by running the MOD RXBRANCH command.

YES

No

None

NO

No

None

Indicates the attenuation of the RX channel of the RRU.

NO

NO

No

None

Indicates the actual physical status of the RX channel of the RRU, the switch of which is set to ON by default. When the logical switch of the RX channel is OFF, the physical switch of the RX channel NO must be OFF. When the logical switch of the RX channel is ON and the RRU is running properly, the physical switch of the RX channel of the RRU can be ON. Indicates the minimum uplink frequency supported by the RRU band 1. For example, if this NO parameter is set to 9250, the minimum uplink frequency of the RRU is 9250 x 0.1 MHz, which equals to 925 MHz.

NO

Yes

None

NO

Yes

None

Indicates the maximum uplink frequency supported by the RRU band 1. For example, if this parameter is set to 9450, the maximum uplink frequency of the RRU is 9450 x 0.1 MHz, which equals to 945 MHz. Indicates the bandwidth supported by each TX channel band 1 in the downlink. This bandwidth is an instantaneous bandwidth. Indicates the minimum uplink frequency supported by the RRU band 2.This parameter is NULL,when the RRU does not supported many bands. For example, if this parameter is set to 9250, the minimum uplink frequency of the RRU is 9250 x 0.1 MHz, which equals to 925 MHz. Indicates the maximum downlink frequency supported by the RRU band 2.This parameter is NULL,when the RRU does not supported many bands. For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the bandwidth supported by each TX channel band 2 in the uplink. This bandwidth is an NO instantaneous bandwidth. This parameter is NULL, when the RRU does not supported multibands.

NO

Yes

None

Indicates the cabinet number of the RRU where the YES TX channel of the RRU is located.

YES

No

None

Indicates the subrack number of the RRU where the YES TX channel of the RRU is located.

YES

No

None

Indicates the slot number of the RRU where the TX YES channel of the RRU is located.

YES

No

None

Indicates the number of the TX YES channel of the RRU.

YES

No

None

Indicates the logical switch of the TX channel of the RRU. This switch is used to open or close the TX channel. The logical switch of the TX channel and the ARFCNs on the TX channel determine the state of the NO physical switch of the TX channel: When this switch is ON and the TX channel is configured with ARFCNs, the physical switch is ON. In other cases, the physical switch is OFF. Indicates the current VSWR of the TX channel of the RRU.

NO

No

None

NO

NO

Yes

None

Indicates the actual physical status of the TX channel of the RRU. The logical switch of the TX channel and the ARFCN on the TX channel determine the state of the physical switch of the TX channel: If NO the logical switch of a TX channel is ON and the ARFCN is configured for the TX channel, the physical switch of the TX channel is ON. In other cases, the physical switch is OFF. Indicates the adjusted output NO power on the TX channel of the RRU. Indicates the test frequency. Different types of RRUs support different frequency ranges. Therefore, the frequency of the cell NO is used as the VSWR test frequency. The default test frequency of an RRU is 65535. Indicates the relative TX power. If this parameter is NO not specified, the maximum power is used by all boards. Indicates the duration of the VSWR test. Indicates the number of the site. Indicates the number of the sector. NO NO NO

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO NO NO

Yes Yes Yes

None None None

Indicates the name NO of the site. Indicates the maximum output power on the TX channel. The adjustment step is 1 W (1000 mW). NO When the output power is set to 0 mW, the maximum output power is unlocked and restored. Indicates the maximum output power on the TX channel. The error is precise to +/-0.5 DB. Indicates the maximum output power of the RRU or RFU TX unit (single carrier). Indicates the maximum output power of the RRU or RFU TX unit (multiple carriers).

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the maximum output power supported by the TX channel hardware. This NO parameter value can have a 0.5 dB difference from the actual maximum output power. Indicates the minimum downlink frequency supported by the RRU band 1. For example, this NO parameter is set to 9650, the minimum downlink frequency of the RRU is 9650 x 0.1 MHz, which equals to 965 MHz.

NO

Yes

None

NO

Yes

None

Indicates the maximum downlink frequency supported by the RRU band 1. For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz. Indicates the bandwidth supported by each TX channel band 1 in the downlink. This bandwidth is an instantaneous bandwidth. Indicates the minimum downlink frequency supported by the RRU band 2. This parameter is NULL,when the RRU does not supported many bands.For example, this parameter is set to 9650, the minimum downlink frequency of the RRU is 9650 x 0.1 MHz, which equals to 965 MHz. Indicates the maximum downlink frequency supported by the RRU band 2. This parameter is NULL,when the RRU does not supported many bands.For example, if this parameter is set to 9850, the maximum downlink frequency of the RRU is 9850 x 0.1 MHz, which equals to 985 MHz.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the bandwidth supported by each TX channel band 2 in the downlink. This bandwidth is NO an instantaneous bandwidth. This parameter is NULL, when the RRU does not supported multibands. Indicates the minimal test NO frequency. Indicates the maximal test NO frequency. . Indicates the result of the cross feed NO test. Indicates the IPv4 address of the NTP YES server.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

No

None

Indicates the period based on which NTP time synchronization is performed periodically. The switch for periodic NTP time synchronization is turned on automatically.The time of an eNodeB may have differences with the standard time, and a large difference affects the accuracy NO of KPIs. Therefore, a period must be configured for the eNodeB to perform time synchronization with the NTP server periodically to ensure the accurate time. The period for periodic NTP time synchronization must be configured based on the NTP server performance, transport network Indicates the port number of the NTP NO server. Indicates the mode of the IP address of YES the NTP server. Indicates the IPv6 address of the NTP YES server. Indicates the mode of the NTP NO authentication.

YES

No

None

NO

No

None

NO

No

None

NO

No

None

NO

No

None

Indicates the key used for NTP authentication. The key used in the DES_S algorithm is a hexadecimal number whose length is 64 bits in binary format. The seven least significant bits of each byte are used to construct 56-bit key data, and the eighth bit is the odd parity bit for each byte. Any empty bit NO is filled with 0 to ensure that the key data is composed of 16 hexadecimal digits and has an odd number for parity check. The key used in the DES_N algorithm is similar to the key used in the DES_S algorithm. The only difference is that in the key used in the DES_N algorithm, the most significant bit is used for parity Indicates the serverside index of the NTP authentication key. The index must NO be the same as the setting on the server. Indicates an NTP server is an active or standby server. Users can run the SET NO MASTERNTPS command to set an NTP server as a master NTP server.

YES

No

None

YES

No

None

NO

No

None

Indicates the time zone of the NE.

NO

NO

No

None

Indicates whether DST is enabled.

NO

NO

No

None

Indicates the mode in which the DST start date is specified. There are three modes: Date, for example, April 1; Day of the week, for example, the first Sunday in April; NO Date plus day of the week, for example, April 1 and Sunday. If it is Sunday on April 1, DST starts on April 1. Otherwise, DST starts on the first Sunday after April 1.

NO

No

None

Indicates the month in which the NE NO DST starts.

NO

No

None

Indicates the day on which the NE DST NO starts.

NO

No

None

Indicates in which week the NE DST starts.

NO

NO

No

None

Indicates the week in which the NE DST starts.

NO

NO

No

None

Indicates the time when the NE DST starts. The value of NO this parameter observes the standard time. Indicates the end date mode of the NE DST. There are three formats: date format, for example, April 1st; week format, for example, the first Sunday in April; NO date and week format, for example, for example, April 1st and Sunday. If it is Sunday on April 1st, April 1st is the date. Otherwise, the first Sunday after April 1st is the date.

NO

No

None

NO

No

None

Indicates the month in which the NE NO DST ends.

NO

No

None

Indicates the day on which the NE DST NO ends.

NO

No

None

Indicates the week NO in which DST ends.

NO

No

None

Indicates the week in which the NE DST ends.

NO

NO

No

None

Indicates the time when the DST of the NE ends. The NO value of this parameter observes DST. Indicates the DST time offset of the NE. This parameter can be set to a negative value. A negative value indicates that the NO NE time is earlier than the DST time, and a positive value indicates that the NE time is later than the DST time.

NO

No

None

NO

No

None

Indicates the offset of time zone. This parameter can be NO set to a negative value. Indicates the date to be set for the NE. The format is as follows: YYYY-MMDD. For example, NO 2006-09-08 indicates September 8th of 2006. Indicates the time to be set for the NE. The format is as NO follows: HH:MM:SS. For example, 10:20:05. Indicates the current date and time of the NE. The query result is the local time of the NE, including the year, month, day, hour, minute, second, and time zone. If the NO DST of the NE is effective, the query result contains a DST flag (the flog used to indicate whether the DST is applied). The format is as follows: YYYYMM-DD HH:MM:SS.

NO

No

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the external reference time source of the NE.

NO

NO

No

None

Indicates the date and time of the last successfullysynchronized time NO of the NE. The format is as follows: YYYY-MM-DD HH:MM:SS.

NO

Yes

None

Indicates the IP address of the FTP YES server.

NO

No

None

Indicates the port of NO the FTP server.

NO

No

None

Indicates the index of the operator.

YES

YES

No

None

Indicates the extended QoS Class Identifier (QCI), which is required by the operator for user differentiation.

YES

YES

No

None

Indicates the ID of a service-based interNO RAT handover policy group.

NO

No

LOFD-001043 / TDLOFD-001043 LOFD-001046 / TDLOFD-001046

Indicates the ID of the service-based inter-frequency handover policy group.

NO

NO

No

LBFD-00201805

Indicates the index of the operator.

YES

YES

No

None

Indicates the QoS Class Identifier (QCI) of an EPS bearer. Different QCIs represent different QoS specifications such as the packet delay YES budget, packet error loss rate, and resource type (whether the service is a GBR service or not). For details, see Table 6.1.7 in 3GPP TS 23.203. Indicates the ID of a service-based interNO RAT handover policy group.

YES

No

None

NO

No

LOFD-001043 / TDLOFD-001043 LOFD-001046 / TDLOFD-001046

Indicates the ID of the service-based inter-frequency handover policy group.

NO

NO

No

LBFD-00201805

Indicates the index of the operator.

YES

YES

No

None

Indicates the highpriority system to be considered in blind NO handovers. It is UTRAN by default.

NO

No

LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035 LOFD-001068 LOFD-001069 LOFD-001052 LOFD-001053 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the medium-priority system to be considered in blind handovers. It is GERAN by default. If this parameter is set to NULL, the NO system with the medium blind handover priority is not specified. In this case, only blind handovers to the high-priority system are applicable.

NO

No

LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the lowpriority system to be considered in blind handovers. It is CDMA2000 by default. If this parameter is set to NULL, the system NO with the low blind handover priority is not specified. In this case, only blind handovers to the high- and mediumpriority systems are applicable.

NO

No

LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the Location Services (LCS) capability of the UTRAN.

NO

NO

No

LOFD-001033 / TDLOFD-001033 LOFD-001047 / TDLOFD-001047

Indicates the Location Services (LCS) capability of the GERAN.

NO

NO

No

LOFD-001034 / TDLOFD-001034 LOFD-001047 / TDLOFD-001047

Indicates the Location Services (LCS) capability of the CDMA2000.

NO

NO

No

LOFD-001035 LOFD-001047 / TDLOFD-001047

Indicates the index of the operator.

YES

YES

No

None

Indicates the mobile country code of the YES target PLMN.

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the mobile network code of the YES target PLMN.

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the ID of the RAT/frequency priority group.

YES

YES

No

LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the Radio Access Technology YES (RAT).

YES

No

LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the downlink EARFCN. Before configuring a priority for an EARFCN specified by this parameter, YES ensure that an external or local cell working on this EARFCN has been configured.

YES

No

LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the priority of the RAT or frequency. The NO value 0 indicates the lowest priority.

NO

No

LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the GERAN frequency band.

NO

NO

No

LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the ID of the operator.

YES

YES

No

LBFD-00201805

Indicates the ID of the service-based inter-frequency handover policy group.

YES

YES

No

LBFD-00201805

Indicates whether the policy group allows a target frequency to be specified for servicebased interfrequency handovers. The value 0 indicates NO that the policy group does not allow a target frequency to be specified, and the value 1 indicates that the policy group allows a target frequency to be specified.

NO

No

LBFD-00201805

Indicates the frequency to which a service with a specified QCI is preferentially handed over.

NO

NO

No

LBFD-00201805

Indicates the index of the operator.

YES

YES

No

LOFD-001043 / TDLOFD-001043 LOFD-001046 / TDLOFD-001046

Indicates the ID of the service-based YES inter-RAT handover policy group.

YES

No

LOFD-001043 / TDLOFD-001043 LOFD-001046 / TDLOFD-001046

Indicates whether inter-RAT handover is required, allowed, NO or not allowed for services with the QCI.

NO

No

LOFD-001043 / TDLOFD-001043 LOFD-001046 / TDLOFD-001046

Indicates the subscriber profile ID YES (SPID).

YES

No

LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045 LOFD-001054 / TDLOFD-001054 LOFD-00105401 / TDLOFD-00105401 LOFD-001059 / TDLOFD-001059

Indicates whether DRX is supported. If this parameter is set to TRUE, ordinary DRX parameters are applied to UEs NO with the SPID. If this parameter is set to FALSE, special DRX parameters are applied to UEs with the SPID.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates whether to specify a NO RAT/frequency priority group.

NO

No

LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045 LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045 LOFD-001054 / TDLOFD-001054 LOFD-00105401 / TDLOFD-00105401 LOFD-001059 / TDLOFD-001059

Indicates the ID of a RAT/frequency NO priority group.

NO

No

Indicates whether to support preallocation. If this parameter is set to TRUE, resources can be preallocated NO to UEs. If this parameter is set to FALSE, resources are not preallocated to UEs. Indicates whether to enable or disable inter-frequency load balancing for the SPID. The values TRUE and FALSE NO indicate that interfrequency load balancing is allowed and prohibited for UEs with the SPID, respectively. Indicates whether to enable or disable inter-RAT load balancing for the SPID. The values TRUE and FALSE NO indicate that interRAT load balancing is allowed and prohibited for UEs with the SPID, respectively. Indicates whether to enable handovers back to the home public land mobile network (HPLMN) for UEs with the SPID. If this function is enabled, a roaming UE can NO be handed over to the HPLMN when this UE moves back to the HPLMN. If this function is disabled, this UE cannot be handed over to the HPLMN based on the SPID.

NO

No

LOFD-001059 / TDLOFD-001059

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the length of the counter check timer. When the timer expires, a counter check procedure is initiated. After the procedure is complete, the timer NO is restarted. A length of 0 indicates that the timer is invalid. In this case, the eNodeB cannot initiate periodic counter check procedures.

NO

No

LBFD-002004 / TDLBFD-002004

Indicates the COUNT value for initiating counter check procedures. When the COUNT value (used at the PDCP layer) of any DRB for a UE is a multiple of the value of this parameter, NO the eNodeB initiates a counter check procedure. The value 0 indicates that the eNodeB does not initiate a counter check procedure based on the COUNT value.

NO

No

LBFD-002004 / TDLBFD-002004

Indicates whether to release a DRB when the counter NO check detects an unexpected result in the DRB.

NO

No

LBFD-002004 / TDLBFD-002004

Indicates the highest-priority ciphering algorithm supported by the NO eNodeB. The value NULL indicates that ciphering is not applied. Indicates the second-priority ciphering algorithm supported by the NO eNodeB. The value NULL indicates that ciphering is not applied. Indicates the thirdpriority ciphering algorithm supported by the eNodeB. The NO value NULL indicates that ciphering is not applied.

NO

No

LOFD-00101001 / TDLOFD-00101001 LOFD-00101002 / TDLOFD-00101002

NO

No

LOFD-00101001 / TDLOFD-00101001 LOFD-00101002 / TDLOFD-00101002

NO

No

LOFD-00101001 / TDLOFD-00101001 LOFD-00101002 / TDLOFD-00101002

Indicates the timer governing the period the eNodeB will NO wait for a response message from the MME.

NO

No

None

Indicates the timer governing the period the eNodeB will NO wait for a response message from the neighboring eNodeB.

NO

No

None

Indicates the timer governing the period the eNodeB will NO wait for a response message from the UE.

NO

No

None

Indicates the highest-priority integrity protection algorithm supported by the eNodeB. The NO value NULL indicates that integrity protection is not applied. Indicates the second-priority integrity protection algorithm supported by the eNodeB. The NO value NULL indicates that integrity protection is not applied.

NO

No

LBFD-002004 / TDLBFD-002004

NO

No

LBFD-002004 / TDLBFD-002004

Indicates the thirdpriority integrity protection algorithm supported by the NO eNodeB. The value NULL indicates that integrity protection is not applied.

NO

No

LBFD-002004 / TDLBFD-002004

Indicates whether to enable or disable NO X2 setup by SON.

NO

No

LBFD-002018 / TDLBFD-002018 LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the method of X2 setup by SON, that is, the method of automatically setting up X2 interfaces. The value NO X2_OVER_M2000 can be set only for Huawei eNodeBs, and the value X2_OVER_S1 can be set for any eNodeB. Indicates whether to enable or disable scheduling request NO indication (SRI) adaptation.

NO

No

LBFD-002018 / TDLBFD-002018 LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

NO

No

LOFD-001015 / TDLOFD-001015

Indicates whether to set a logical channel group profile. Currently, two logical channel group profiles are available: LCG_PROFILE_0 and LCG_PROFILE_1. If LCG_PROFILE_0 is used, only one NO logical channel group is assigned to non-GBR services. If LCG_PROFILE_1 is used, two logical channel groups are assigned to nonGBR services: one to high-priority nonGBR services and the other to lowpriority non-GBR services. Indicates whether to enable or disable RAN information management (RIM) for handovers in RNC pool scenarios. An RNC NO pool can be used for load balancing between RNCs. A cell under an RNC can be controlled by another RNC in the RNC pool.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

NO

No

LOFD-001019 / TDLOFD-001019

Indicates whether an eNodeB uses serial or parallel message transmission mode during security mode activation and RRC reconfiguration NO procedures. If this parameter is set to ON, the eNodeB uses parallel transmission mode. If this parameter is set to OFF, the eNodeB uses serial transmission mode.

NO

No

LBFD-002007 / TDLBFD-002007

None

NO

NO

No

None

Indicates whether to enable ROHC. Set this parameter to ON if the eNodeB NO is expected to support VoIP or video services.

NO

No

LOFD-001017 / TDLOFD-001017

Indicates the operating mode of ROHC. In Unidirectional Mode (U-Mode), packets are sent only from the compressor to the decompressor, and a feedback channel is not mandatory. Therefore, U-Mode is less reliable than Bidirectional Optimistic Mode (OMode) and Bidirectional NO Reliable Mode (RMode), but its feedback-induced overhead is minimum compared with the overhead in O-Mode and RMode. In O-Mode, the decompressor can send feedback messages to the compressor to indicate decompression failures or successful context updates. O-Mode is

NO

No

LOFD-001017 / TDLOFD-001017

Indicates the compression profile supported by the eNodeB. Under the ROHC framework, header compression algorithms vary with protocols. Profiles define the header compression protocols (such as RTP/UDP/IP or TCP/IP), which are under the same ROHC framework, for specific types of NO packet streams. Each profile has a unique identifier. As defined by LTE specifications, the eNodeB supports the following profiles: profile 0x0001 (usage: RTP/UDP/IP; reference: RFC 3095 and RFC 4815), profile 0x0002 (usage: UDP/IP; reference: RFC 3095 and RFC 4815), profile

NO

No

LOFD-001017 / TDLOFD-001017

Indicates the length of timer T302. T302 specifies the wait time for retransmitting an RRCConnectionRe quest message after the previous request with a cause other than "MO-Data" and "MOSignalling" is NO rejected. This timer is started after the UE receives the RRCConnectionRej ect message. This timer is stopped when the UE enters the RRC_CONNECTE D mode or performs cell reselection.

NO

No

LBFD-002007 / TDLBFD-002007

Indicates the length of timer T320 for load balancing. T320 specifies the time period during which the dedicated priorities (used for cell reselection) retain valid. The time period is contained in the RRCConnectionRel ease message that is received by the UE. After T320 NO expires, the dedicated priorities become invalid. This timer is started when the UE receives an RRCConnectionRel ease message containing the t320 IE. This timer is stopped when the UE enters the RRC_CONNECTE D mode.

NO

No

LBFD-002018 / TDLBFD-002018 LBFD-00201803 / TDLBFD-00201803

Indicates the length of timer T304 for intra-RAT handover. If the UE does not complete the handover before this timer expires, NO the UE reverts back to the associated configuration and initiates an RRC connection reestablishment procedure.

NO

No

LBFD-002018 / TDLBFD-002018 LBFD-00201803 / TDLBFD-00201803

Indicates the length of timer T304 for inter-RAT handover to GERAN. If the UE does not complete the handover before this timer expires, NO the UE reverts back to the associated configuration and initiates an RRC connection reestablishment procedure. Indicates the length of timer T320 to be contained in RRCConnectionRel ease messages sent for reasons other than load balancing. T320 specifies the time period during which the dedicated priorities (used for cell reselection) are valid. After T320 expires, the dedicated priorities become invalid. NO This parameter is invalid for UEs to be redirected based on the subscriber profile ID (SPID). This timer is started when the UE receives an RRCConnectionRel ease message containing the t320 IE. It is stopped when the UE enters the RRC_CONNECTE D mode.

NO

No

LBFD-002018 / TDLBFD-002018 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-002018 / TDLBFD-002018 LBFD-00201803 / TDLBFD-00201803

Indicates the length of the UE inactivity timer. The eNodeB monitors whether UEs are receiving or sending data. When a UE has neither received nor sent data for a NO duration exceeding this period of time, the eNodeB releases the radio resources for the UE. If this parameter is set to 0, the UE inactivity timer is not used.

NO

No

LBFD-002007 / TDLBFD-002007

Indicates the timer used to govern the period in which the eNodeB maintains uplink synchronization for a UE. After this timer expires, the eNodeB does not send Timing Advance Command to the UE. If this NO parameter is set to 0, this parameter does not take effect and, as a result, the eNodeB will constantly send Timing Advance Command to the UE to maintain uplink synchronization for the UE.

NO

No

LBFD-002007 / TDLBFD-002007

Indicates the ID of the TCE for MDT.

YES

YES

No

None

Indicates the IP address version. IPv4(IPv4 Address) indicates that the NO version is IPv4. IPv6(IPv6 Address) indicates that the version is IPv6.

NO

No

None

Indicates the IPv4 NO address of the TCE.

NO

No

None

Indicates the IPv6 NO address of the TCE.

NO

No

None

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the switch for adjusting the PA through power control on the PDSCH. If this parameter is set to NO ON, the PA is adjusted dynamically when the channel quality is extremely good or bad.

YES

No

None

NO

No

LBFD-002016 / TDLBFD-002016

Indicates the PA to be used when PA adjustment for PDSCH power control is disabled, NO downlink ICIC is disabled, and the even power distribution is used for the PDSCH.

NO

No

LBFD-002016 / TDLBFD-002016

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the threshold for UEs to enter DRX in the cell that operates in FDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time intervals (TTIs) with NO data transmission to the total TTIs. If the traffic volume at a UE is equal to or lower than this threshold, the eNodeB decides that the UE should retain its DRX state or enter DRX. Indicates the threshold for UEs to exit DRX in the cell that operates in FDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time intervals (TTIs) with NO data transmission to the total TTIs. If the traffic volume at a UE is equal to or higher than this threshold, the eNodeB decides that the UE should retain its non-DRX state or exit DRX.

NO

No

LBFD-002017 / TDLBFD-002017

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the uplink traffic volume threshold for UEs to enter DRX in the cell that operates in TDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time intervals (TTIs) with NO uplink data transmission to the total TTIs. If the traffic volume at a UE is equal to or lower than this threshold, the eNodeB decides that the UE should retain its DRX state or enter DRX. Indicates the uplink traffic volume threshold for UEs to exit DRX in the cell that operates in TDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time intervals (TTIs) with NO uplink data transmission to the total TTIs. If the traffic volume at a UE is equal to or higher than this threshold, the eNodeB decides that the UE should retain its non-DRX state or exit DRX.

NO

No

LBFD-002017 / TDLBFD-002017

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the downlink traffic volume threshold for UEs to enter DRX in the cell that operates in TDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time NO intervals (TTIs) with downlink data transmission to the total TTIs. If the traffic volume at a UE is equal to or lower than this threshold, the eNodeB decides that the UE should retain its DRX state or enter DRX. Indicates the downlink traffic volume threshold for UEs to exit DRX in the cell that operates in TDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time NO intervals (TTIs) with downlink data transmission to the total TTIs. If the traffic volume at a UE is equal to or higher than this threshold, the eNodeB decides that the UE should retain its non-DRX state or exit DRX.

NO

No

LBFD-002017 / TDLBFD-002017

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the UE traffic measurement period. The traffic volume of a UE during this period is measured. Based NO on the measurement result, the DRX algorithm decides whether the UE should enter or exit DRX. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates whether the transmit power of the UE is adjusted according to the difference between MCSs. indication is contained in an RRC message signaled to the UE. In the message,this indication occupies NO one bit. The value 0, which means disabled, indicates that TF is equal to 0 because Ks is equal to 0. The value 1, which means enabled, indicates that TF is calculated on the condition that Ks is equal to 1.25.

NO

No

LBFD-002017 / TDLBFD-002017

YES

No

None

NO

No

LBFD-002026 / TDLBFD-002026

Indicates the power offset of the sounding reference signal to the NO PUSCH when DeltaMcsEnabled is set to UU_DISABLE.

NO

No

LBFD-002026 / TDLBFD-002026

Indicates the power offset of the sounding reference signal to the NO PUSCH when DeltaMcsEnabled is set to UU_ENABLE.

NO

No

LBFD-002026 / TDLBFD-002026

Indicates the alpha filtering coefficient used by the UE during RSRP NO measurement for path loss estimation.

NO

No

LBFD-002026 / TDLBFD-002026

Indicates the local identity of the cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the measurement object type for distance-based handovers.

NO

NO

No

LOFD-001072 / TDLOFD-001072 LOFD-001073 / TDLOFD-001073 LBFD-00201804 / TDLBFD-00201804

Indicates the threshold for distance-based handovers. If the distance between a UE and the cell NO center is greater than this threshold, a distance-based handover is triggered for this UE.

NO

No

LBFD-00201804 / TDLBFD-00201804 LOFD-001072 / TDLOFD-001072 LOFD-001073 / TDLOFD-001073

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the ID of the DRX parameter YES group.

YES

No

None

Indicates whether bearers to which the parameter group applies support DRX. The value ON indicates that the bearers support DRX. The value NO OFF indicates that the bearers do not support DRX. A UE can enter the DRX mode only when all bearers running on it support DRX.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the On Duration Timer. Due to the impact of CQI reporting intervals and SRS transmission NO intervals, there is a possibility that the actual value of this parameter assigned to a UE is larger than the configured value.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the DRX NO Inactivity Timer.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the DRX NO Retransmission Timer.

NO

No

LBFD-002017 / TDLBFD-002017 LBFD-002005 / TDLBFD-002005

Indicates the length of a long DRX NO cycle.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates whether short DRX cycles are enabled.

NO

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of a short DRX NO cycle.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the DRX Short Cycle Timer. If this parameter is set to 1, the length of this timer is one short DRX cycle. If this parameter is set to 2, the length of this timer is two short NO DRX cycles. If this parameter is set to a large value, a UE for which short DRX cycles are enabled stays in short-cycle DRX for a long time. For details, see 3GPP TS 36.321 5.7.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the common parameter group YES related to inter-RAT handover.

YES

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023

Indicates the hysteresis for interRAT measurement events A1 and A2. This parameter is used to prevent frequent triggering of event evaluation caused by radio NO signal fluctuation. In this way, the probability of pingpong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001021 LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the time-totrigger for inter-RAT measurement event A1 or A2. When detecting that the signal quality in the serving cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously NO meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers, and the number of wrong handovers. In summary, it helps prevent unnecessary handovers.

NO

No

LOFD-001023 / TDLOFD-001023 LOFD-001022 / TDLOFD-001022 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the RSRP threshold for interRAT measurement event A1. When the measured RSRP NO value of the serving cell exceeds this threshold, an event A1 report will be sent.

NO

No

LOFD-001023 / TDLOFD-001023 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022

Indicates the RSRQ threshold for interRAT measurement event A1. When the measured RSRQ NO value of the serving cell exceeds this threshold, an event A1 report will be sent.

NO

No

LOFD-001023 / TDLOFD-001023 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022

Indicates the RSRP threshold for interRAT measurement event A2. When the measured RSRP NO value of the serving cell is below this threshold, an event A2 report will be sent.

NO

No

LOFD-001023 / TDLOFD-001023 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022

Indicates the RSRQ threshold for interRAT measurement event A2. When the measured RSRQ NO value of the serving cell is below this threshold, an event A2 report will be sent.

NO

No

LOFD-001023 / TDLOFD-001023 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022

Indicates the offset of the A2 threshold for inter-RAT blind redirection against NO the A2 threshold for inter-RAT handovers.

NO

No

LBFD-002018

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the parameter group related to YES inter-RAT handover to CDMA2000 1xRTT.

YES

No

LOFD-001021

Indicates the hysteresis for event B1 for inter-RAT handover to CDMA2000 1xRTT. This parameter is used to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In this way, the NO probability of pingpong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability of ping-pong handovers or handover decision errors.

NO

No

LOFD-001021

Indicates the pilot strength threshold for event B1 related to coverage-based inter-RAT handover to CDMA2000 NO 1xRTT. When the measurement value exceeds this threshold, a measurement report will be sent.

NO

No

LOFD-001021

Indicates the time-totrigger for event B1 related to inter-RAT handover to CDMA2000 1xRTT. When detecting that the signal quality in at least one neighboring cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only NO when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers and the number of wrong handovers, preventing unnecessary Indicates the pilot strength threshold for event B1 related to load- or servicebased inter-RAT handover to CDMA2000 1xRTT. NO When the measurement value exceeds this threshold, a measurement report will be sent.

NO

No

LOFD-001021

NO

No

LOFD-001021

Indicates the extended QCI.

YES

YES

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of a parameter group related to interNO frequency handover.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the ID of a parameter group related to inter-RAT NO handover to CDMA2000 1xRTT.

NO

No

LOFD-001021

Indicates the ID of a parameter group related to inter-RAT NO handover to CDMA2000 HRPD.

NO

No

LOFD-001021

Indicates the ID of a group of common parameters related NO to inter-RAT handover.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the ID of a parameter group related to inter-RAT NO handover to GERAN.

NO

No

LOFD-001020 / TDLOFD-001020

Indicates the ID of a parameter group related to inter-RAT NO handover to UTRAN.

NO

No

LOFD-001019 / TDLOFD-001019

Indicates the ID of a parameter group related to intraNO frequency handover.

NO

No

LBFD-00201801 / TDLBFD-00201801

Indicates the ID of a DRX parameter NO group.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the QoS class identifier (QCI) of an evolved packet system (EPS) bearer. Different QCIs indicate different QoS requirements, YES such as the packet delay budget, packet error loss rate, and resource type. For details, see Table 6.1.7 in 3GPP TS 23.203. Indicates the ID of a parameter group related to interNO frequency handovers. Indicates the ID of a parameter group related to inter-RAT NO handover to CDMA2000 1xRTT. Indicates the ID of a parameter group related to inter-RAT NO handover to CDMA2000 HRPD.

YES

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

NO

No

LBFD-00201802 / TDLBFD-00201802

NO

No

LOFD-001021

NO

No

LOFD-001021

Indicates the ID of a common parameter NO group related to inter-RAT handover.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the ID of a parameter group related to inter-RAT NO handover to GERAN.

NO

No

LOFD-001020 / TDLOFD-001020

Indicates the ID of a parameter group related to inter-RAT NO handover to UTRAN. Indicates the ID of a parameter group related to intraNO frequency handover.

NO

No

LOFD-001019 / TDLOFD-001019

NO

No

LBFD-00201801 / TDLBFD-00201801

Indicates the ID of a DRX parameter NO group.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the interval at which NO scheduling request indicators are sent.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the parameter group related to YES inter-RAT handover to CDMA2000 HRPD.

YES

No

LOFD-001021

Indicates the hysteresis for event B1 related to interRAT handover to CDMA2000 HRPD. This parameter is used to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In this way, the NO probability of pingpong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability of ping-pong handovers or handover decision errors.

NO

No

LOFD-001021

Indicates the pilot strength threshold for event B1 related to load- or servicebased inter-RAT handover to CDMA2000 HRPD. NO When the measurement value exceeds this threshold, a measurement report will be sent. Indicates the time-totrigger for event B1 related to inter-RAT handover to CDMA2000 HRPD. When detecting that the signal quality in at least one neighboring cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only NO when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers and the number of wrong handovers, preventing unnecessary

NO

No

LOFD-001021

NO

No

LOFD-001021

Indicates the pilot strength threshold for event B1 related to load- or servicebased inter-RAT handover to CDMA2000 HRPD. NO When the measurement value exceeds this threshold, a measurement report will be sent.

NO

No

LOFD-001021 LOFD-001032 / TDLOFD-001032

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the parameter group related to YES inter-RAT handover to GERAN.

YES

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023

Indicates the hysteresis for event B1 related to interRAT handover to GERAN. This parameter is used to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In this way, the probability NO of ping-pong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability of ping-pong handovers or handover decision errors.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001046 / TDLOFD-001046

Indicates the RSSI threshold for event B1 related to coverage-based inter-RAT handover to GERAN. A UE sends a measurement report related to event B1 NO to the eNodeB when the RSSI in at least one GERAN cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP TS 36.331.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023

Indicates the time-totrigger for event B1 related to inter-RAT handover to GERAN. When detecting that the signal quality in at least one neighboring cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only NO when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers and the number of wrong handovers, preventing unnecessary

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001046 / TDLOFD-001046

Indicates the RSSI threshold for event B1 related to loador service-based inter-RAT handover to GERAN. NO When the measured RSSI value exceeds this threshold, a measurement report will be sent.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001032 / TDLOFD-001032 LOFD-001046 / TDLOFD-001046

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the parameter group related to YES inter-RAT handover to UTRAN.

YES

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the Ec/No threshold for event B1 related to coverage-based inter-RAT handover to UTRAN. This parameter specifies the requirement for Ec/No of the target UTRAN cell. For a cell with large signal fading variance, set this parameter to a large value to prevent unnecessary NO handovers. For a cell with small signal fading variance, set this parameter to a small value to ensure timely handovers. A large value of this parameter results in a low probability of handover to the UTRAN cell, and a small value leads to a high probability. When the measurement value Indicates the RSCP threshold for event B1 related to coverage-based inter-RAT handover to UTRAN. This parameter specifies the requirement for NO RSCP of the target UTRAN cell. When the measurement value exceeds this threshold, a measurement report will be sent.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the hysteresis for event B1 related to interRAT handover to UTRAN. This parameter is used to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In this way, the probability NO of ping-pong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability of ping-pong handovers or handover decision errors.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001043 / TDLOFD-001043

Indicates the time-totrigger for event B1 related to inter-RAT handover to UTRAN. When detecting that the signal quality in at least one neighboring cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only NO when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers and the number of wrong handovers, preventing unnecessary

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001043 / TDLOFD-001043

Indicates the Ec/No threshold for event B1 related to loador service-based inter-RAT handover to UTRAN. This parameter specifies the requirement for Ec/No of the target UTRAN cell. When the measurement value exceeds this threshold, a measurement report NO may be sent. For a cell with large signal fading variance, set this parameter to a large value to prevent unnecessary handovers. For a cell with small signal fading variance, set this parameter to a small value to ensure timely handovers. Indicates the RSCP threshold for event B1 related to loador service-based inter-RAT handover to UTRAN. This parameter specifies the requirement for NO RSCP of the target UTRAN cell. When the measurement value exceeds this threshold, a measurement report will be sent.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001032 / TDLOFD-001032 LOFD-001043 / TDLOFD-001043

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001032 / TDLOFD-001032 LOFD-001043 / TDLOFD-001043

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the parameter group related to inter-frequency handover.

YES

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the hysteresis for interfrequency measurement events A1 and A2. This parameter is used to prevent frequent triggering of event evaluation caused by radio NO signal fluctuation. In this way, the probability of pingpong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the time-totrigger for interfrequency measurement event A1 or A2. When detecting that the signal quality in the serving cell meets the triggering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal NO quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers, and the number of wrong handovers. In summary, it helps prevent unnecessary

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRP threshold for interfrequency measurement event A1. When the NO measured RSRP value exceeds this threshold, a measurement report will be sent.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRQ threshold for interfrequency measurement event A1. When the NO measured RSRQ value exceeds this threshold, a measurement report will be sent.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRP threshold for interfrequency measurement event A2. When the NO measured RSRP value is below the threshold, a measurement report will be sent.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRQ threshold for interfrequency measurement event A2. When the NO measured RSRQ value is below this threshold, a measurement report may be sent.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the hysteresis for event A4. This parameter is used to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In NO this way, the probability of pingpong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRP threshold for event A4 related to coverage-based inter-frequency handover. When the measured NO RSRP value exceeds this threshold, an interfrequency measurement report will be sent.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRQ threshold for event A4 related to coverage-based inter-frequency handover. When the measured NO RSRQ value exceeds this threshold, an interfrequency measurement report will be sent.

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the time-totrigger for event A4 for the interfrequency handover. When detecting that the signal quality in at least one neighboring cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only NO when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers, and the number of wrong handovers. In summary, it helps prevent

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the RSRP threshold for event A4 related to loador frequency-prioritybased interfrequency handover. When NO the measured RSRP value exceeds this threshold, an interfrequency measurement report will be sent.

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the RSRQ threshold for event A4 related to loador frequency-prioritybased interfrequency handover. When NO the measured RSRQ value exceeds this threshold, an interfrequency measurement report will be sent.

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the RSRP threshold for frequency-prioritybased interfrequency measurement event A1. When the measured RSRP value exceeds this threshold, an event A1 report will be NO sent. The value 141 does not take effect, and is reserved for backward compatibility. If this parameter is set to 141, the value -140 is used as the threshold in implementation.

NO

No

None

Indicates the RSRQ threshold for frequency-prioritybased interfrequency measurement event A1. NO When the measured RSRQ value exceeds this threshold, an event A1 report may be sent. Indicates the offset for event A3 associated with inter-frequency handover. This parameter determines the border between the serving cell and the neighboring cell. If the parameter is set to a large value, an inter-frequency NO handover is performed only when the signal quality of the neighboring cell is significantly better than that of the serving cell and other triggering conditions are met. For details, see 3GPP TS 36.331.

NO

No

None

NO

No

LBFD-00201802

Indicates the RSRP threshold for event A1 associated with event-A3-triggered inter-frequency handover. NO When the measured RSRP value exceeds this threshold, a measurement report will be sent.

NO

No

LBFD-00201802

Indicates the RSRP threshold for event A2 associated with event-A3-triggered inter-frequency handover. When NO the measured RSRP value is below the threshold, a measurement report will be sent.

NO

No

LBFD-00201802

Indicates the RSRP threshold for frequency-prioritybased interfrequency measurement event NO A2. If the measured RSRP value is less than this threshold, an event A2 report will be sent.

NO

No

None

Indicates the RSRQ threshold for interfrequency measurement event A2. When the NO measured RSRQ value is below this threshold, a measurement report will be sent.

NO

No

None

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the ID of the parameter group related to intra-frequency handover.

YES

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the hysteresis for event A3 associated with intra-frequency handover. This parameter prevents frequent triggering of event evaluation due to radio signal fluctuations. This reduces the probability of pingpong handovers or NO handover decision errors. A larger value of this parameter results in a lower probability. The hysteresis for event A3 associated with inter-frequency handover is the same as the value of this parameter. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801 LOFD-001032 / TDLOFD-001032

Indicates the offset for event A3. If the parameter is set to a large value, an intra-frequency handover is performed only when the signal quality of the NO neighboring cell is significantly better than that of the serving cell and other triggering conditions are met. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801

Indicates the time-totrigger for event A3 associated with intra-frequency handover. When the UE detects that the signal quality in the serving cell and that in at least one neighboring cell meet the entering condition, it does not immediately send a measurement report to the eNodeB. NO Instead, the UE sends a report only when the signal quality meets the entering condition throughout the timeto-trigger. This parameter helps decrease the number of occasionally triggered event reports, the average number of handovers, and the number of incorrect handovers,

NO

No

LBFD-00201801 / TDLBFD-00201801

Indicates the index of the operator.

YES

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the name of the operator. The name is a string of a maximum of 32 characters. The string cannot be all null characters or contain any of the following characters: double quotation marks ("), NO commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive spaces, and two or more consecutive percent signs (%). Indicates the type of the operator. The operator can be the primary operator or a secondary operator. For each NO eNodeB, only one primary operator but more than one secondary operator can be configured. Indicates the mobile country code (MCC) NO of the operator. Indicates the mobile network code (MNC) of the operator. The value of this parameter is NO a string of two or three characters, each of which must be a digit in the range from 0 to 9.

YES

No

None

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

None

YES

No

None

Indicates the ID of the IP path.

YES

YES

No

None

Indicates the ID of the operator.

NO

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the tracking area ID, which uniquely YES identifies an entry of tracking area information.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the index of the operator.

NO

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the tracking area code (TAC), which is used by the EPC to determine the area within which paging messages are sent. One tracking area is comprised of one or more cells. Two TAC values NO 0x0000(0) and 0xFFFE(65534) are reserved according to the protocol and will not be used in future versions. Therefore, do not use 0 or 65534 as a TAC value in TAC planning or configuration. Indicates the index of the operator.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates whether to enable or disable emergency calls. It is recommended that this parameter NO be set to a value in accordance with the actual emergency call capability of the operator. Indicates whether the operator supports emergency calls initiated by UEs in limited mode. Indicates the Allocation and Retention Priority (ARP) value of the dedicated emergency call bearer.

NO

No

LBFD-002028 / TDLBFD-002028

NO

NO

No

LBFD-002028 / TDLBFD-002028

NO

NO

No

LBFD-002028 / TDLBFD-002028

Indicates the Allocation and Retention Priority (ARP) value of the default emergency call bearer.

NO

NO

No

LBFD-002028 / TDLBFD-002028

Indicates the eNodeB sharing mode, which can be independent Operator Mode, NO Shared Frequency Sharing Mode, or Separate Frequency Sharing Mode.

NO

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the index of the operator.

YES

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the proportion of the maximum number of users for the operator at the shared eNodeB. This parameter must be set according to the contract signed by the operators.

NO

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037 LBFD-004014

Indicates the minimum length of NO the S1 reestablishment timer. Indicates the maximum length of NO the S1 reestablishment timer.

NO

No

None

NO

No

None

Indicates the ID of the S1 interface.

YES

YES

No

LOFD-001018 / TDLOFD-001018

Indicates the ID of the Stream Control Transmission Protocol (SCTP) link on the S1 interface. Indicates the ID of the operator that owns the S1 interface.

NO

YES

No

LOFD-001018 / TDLOFD-001018

NO

YES

No

LOFD-001018 / TDLOFD-001018 LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the compliance protocol release of the MME to which the eNodeB is connected through the S1 interface. The value of this parameter must be the same as the MME-complied protocol release. The eNodeB sends S1 messages NO complying with the protocol release specified by this parameter. If the parameter value is different from the MME-complied protocol release, the way in which the MME handles these message is subject to the MME implementation.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates whether the S1 interface is blocked.

NO

NO

No

None

Indicates the status NO of the S1 interface. Indicates the status of the SCTP link on NO the S1 interface. Indicates whether the MME connected NO to the eNodeB is overloaded. Indicates the number of users NO that have accessed the S1 interface. Indicates the name of the MME to which the eNodeB NO is connected through the S1 interface. Indicates the IDs of all served PLMNs of the MMEs to which the eNodeB is connected. The ID NO of a served PLMN consists of the MCC and MNC. PLMN IDs are separated by commas (,). Indicates the Global Unique MME Identifiers (GUMMEIs) of all MMEs to which the eNodeB is connected. A GUMMEI of a NO serving MME consists of the MCC, MNC, MME group ID, and MME code. GUMMEIs are separated by commas (,).

NO

Yes

None

NO

Yes

None

NO

Yes

LOFD-001018 / TDLOFD-001018

NO

Yes

None

NO

Yes

None

NO

Yes

LOFD-001018 / TDLOFD-001018 LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

NO

Yes

None

Indicates the load of the connected MME relative to that of other MMEs. A NO larger value of this parameter indicates a larger capacity allowing UE access.

NO

Yes

None

Indicates the reason of the Fault on the NO S1 link.

NO

Yes

None

Indicates the ID of an S1 interface.

YES

YES

No

None

Indicates whether the MME at the other end of the S1 interface supports Huawei-proprietary positioning procedures, which are included in minimization of drive tests (MDT). The value DISABLE indicates that the NO MME does not support the procedures and therefore the eNodeB cannot obtain UE location information from the MME through the procedures. The value ENABLE indicates the opposite. Indicates the mobile country code of the neighboring eNodeB to be added to the list. The value of this YES parameter is a string of three characters, each of which must be a digit in the range of 0 to 9. Indicates the mobile network code of the neighboring eNodeB to be added to the list. The value of this YES parameter is a string of two or three characters, each of which must be a digit in the range of 0 to 9.

NO

No

None

YES

No

None

YES

No

None

Indicates the ID of the neighboring eNodeB to be added to the list.

YES

YES

No

None

Indicates whether the list is a blacklist NO or whitelist.

NO

No

None

Indicates the ID of the X2 interface.

YES

YES

No

LBFD-002018 / TDLBFD-002018 LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the ID of the Stream Control Transmission Protocol (SCTP) link on the X2 interface. Indicates the ID of the operator that owns the X2 interface.

NO

YES

No

None

NO

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the protocol release NO with which the peer eNodeB complies.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates whether the X2 interface can be automatically removed when the peer-eNodeB configuration is deleted. This parameter is valid only when peereNodeB information for SON is configured. This parameter will be NO removed in later versions. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter. Indicates the ID of the neighboring eNodeB to which the local eNodeB is connected through the X2 interface. The combination of NO this parameter and NbrEnbPlmnId uniquely identifies the neighboring eNodeB around the globe. Indicates the PLMN ID of the neighboring eNodeB to which NO the local eNodeB is connected through the X2 interface. Indicates the status NO of the X2 interface.

NO

No

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the reason why the X2 interface NO is abnormal.

NO

Yes

None

Indicates the DRX switch.

NO

NO

No

LBFD-002017 / TDLBFD-002017

Indicates whether to enable or disable short DRX cycles. NO Short DRX cycles reduce the traffic delay.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of a long DRX cycle that is applied only to non-powersaving UEs whose subscriber profile ID for RAT/frequency priority (RFSP) indexes are contained in the RFSP index set. NO Due to the impact of CQI reporting periods and SRS transmission periods, the actual value of this parameter assigned to a UE may be less than the configured value.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the On Duration Timer that applies only to non-powersaving UEs whose RFSP indexes are contained in the RFSP index set. For details about this timer, see 3GPP TS 36.321. Due to the NO impact of CQI reporting intervals and SRS transmission intervals, there is a possibility that the actual value of this parameter assigned to a UE is larger than the configured value.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the DRX Inactivity Timer that applies only to nonpower-saving UEs whose RFSP NO indexes are contained in the RFSP index set. For details about this timer, see 3GPP TS 36.321.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates whether to enable or disable short DRX cycles for non-powerNO saving UEs whose RFSP indexes are contained in the RFSP index set.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of a short DRX cycle that applies only to non-powerNO saving UEs whose RFSP indexes are contained in the RFSP index set.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the length of the DRX Short Cycle Timer that applies only to nonpower-saving UEs whose RFSP indexes are contained in the RFSP index set. The length of this timer is expressed in the number of NO short DRX cycles. If this parameter is set to 1, the length of this timer is one short DRX cycle. If this parameter is set to 2, the length of this timer is two short DRX cycles. For details, see 3GPP TS 36.321 5.7.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the long DRX cycle for intraRAT ANR. If intraRAT ANR is enabled, this NO parameter takes effect regardless of whether DRX is enabled.

NO

No

LBFD-002017

Indicates the long DRX cycle for interRAT ANR. If interRAT ANR is enabled, this NO parameter is valid regardless of whether DRX is enabled.

NO

No

LBFD-002017 / TDLBFD-002017

Indicates the extended QoS Class Identifier (QCI), which is required by the operator for user differentiation.

YES

YES

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

Indicates the service type corresponding to the extended QCI.

NO

NO

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

Indicates the weight factor used in the calculation of NO connection priorities during uplink scheduling. Indicates the weight factor used in the calculation of NO connection priorities during downlink scheduling.

NO

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

NO

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

Indicates the uplink minimum guaranteed bit rate NO of the non-GBR service.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the downlink minimum guaranteed bit rate of the non-GBR service.

NO

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the preallocation weight. The pre-allocation weight of a UE is the pre-allocation weight of services carried by the highest-priority logical channel. If services carried by highest-priority logical channels have different preallocation weights, the UE takes the highest preNO allocation weight. When resources are insufficient, preallocation weights affect the preallocation probabilities of users. The preallocation probability has a positive correlation with the preallocation weight. This parameter is QCI-specific.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the group ID of the parameters related NO to the inter-RAT handover with the extended QCI.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023 LOFD-001043 / TDLOFD-001043 LOFD-001045 / TDLOFD-001045 LOFD-001044 / TDLOFD-001044 LOFD-001046 / TDLOFD-001046 LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035

Indicates the prioritized bit rate of the logical channel. The UE scheduler guarantees prioritized bit rates NO of logical channels in descending order of logical channel priority. For details, see 3GPP TS 36.321.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the priority of the logical channel. The UE scheduler guarantees prioritized bit rates of logical channels in descending order of logical channel priority. Resources NO are allocated in descending order of logical channel priority after the prioritized bit rates of all services are guaranteed. For details, see 3GPP TS 36.321. Indicates the ID of an RLC/PDCP parameter group.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

NO

NO

No

LBFD-002008 / TDLBFD-002008

Indicates whether the extended QCI is NO specific to free users or paid users.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates whether to enable flow control NO for the QCI.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103 LOFD-00301202 / TDLOFD-00301202 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the group ID of the parameters related YES to the inter-RAT handover with a specific QCI.

YES

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023 LOFD-001032 / TDLOFD-001032 LOFD-001043 / TDLOFD-001043 LOFD-001045 / TDLOFD-001045 LOFD-001044 / TDLOFD-001044 LOFD-001046 / TDLOFD-001046 LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035

PS_HO: Indicates the switch used to enable or disable the QCI-specific PS handover to UTRAN. If this switch is set to On, the UE can perform the PS handover to the UTRAN cell. If this switch is set to Off, the UE cannot perform the PS handover to the UTRAN cell. SRVCC: Indicates NO the switch used to enable or disable the QCI-specific SRVCC handover to UTRAN. If this switch is set to On, the UE can perform the SRVCC handover to the UTRAN cell. If this switch is set to Off, the UE cannot perform the SRVCC handover to the UTRAN cell. REDIRECTION: Indicates the switch Indicates the switch used to enable or disable the single radio voice call continuity (SRVCC) handover to GERAN GSM. If this switch is set to On, the UE can NO perform the SRVCC handover to the GERAN GSM cell. If this switch is set to Off, the UE cannot perform the SRVCC handover to the GERAN GSM cell.

NO

No

LOFD-001022 / TDLOFD-001022 LOFD-001019 / TDLOFD-001019

NO

No

LOFD-001023 / TDLOFD-001023

Indicates the policy of handovers to GPRS/EDGE. PS_HO: Indicates whether PS handovers to neighboring GPRS/EDGE cells are allowed. NACC_HO: Indicates whether NACC handovers to neighboring GPRS/EDGE cells are allowed. This switch will be removed in the later NO versions. In this version, the setting of this switch is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter. CCO_HO: Indicates whether CCO handovers to neighboring GPRS/EDGE cells are allowed. Indicates the switch used to enable or disable QCI-specific SRVCC to CDMA2000 1xRTT. If this switch is turned on, UEs can perform SRVCC to NO CDMA2000 1xRTT cells. If this switch is turned off, UEs cannot perform SRVCC to CDMA2000 1xRTT cells.

NO

No

LOFD-001020 / TDLOFD-001020

NO

No

LOFD-001021

PS_HO: Indicates the switch used to enable or disable the QCI-specific PS handover to CDMA2000 HRPD. If this switch is set to On, the UE can perform the PS handover to the CDMA2000 HRPD cell. If this switch is set to Off, the UE cannot perform the PS handover to the CDMA2000 HRPD NO cell. OMT_HO: Indicates the switch used to enable or disable the QCI-specific OMT handover to CDMA2000 HRPD. If this switch is set to On, the UE can perform the OMT handover to the CDMA2000 HRPD cell. If this switch is set to Off, the UE cannot perform the OMT handover to

NO

No

LOFD-001021

Indicates whether to permit or forbid the NO inter-RAT handover under the QCI.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023 LOFD-001032 / TDLOFD-001032 LOFD-001043 / TDLOFD-001043 LOFD-001045 / TDLOFD-001045 LOFD-001044 / TDLOFD-001044 LOFD-001046 / TDLOFD-001046 LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035

Indicates whether to allow or prohibit the NO fast ANR under the QCI.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the index mapped to the MCS offset for channel quality indicators NO (CQIs) transmitted with data on PUSCH.

NO

No

None

Indicates the index mapped to the MCS offset for rank indications (RIs) transmitted with data on PUSCH. The protocol does not recommend the values 13, 14, and NO 15. If this parameter is set to 13, 14, or 15, If this value is used, the UE performance may deteriorate. For details, see 3GPP TS 36.213. Indicates the index mapped to the MCS offset for acknowledgments (ACKs) transmitted with data on PUSCH. The protocol does not recommend the NO value 15. If this parameter is set to 15, If this value is used, the UE performance may deteriorate. For details, see 3GPP TS 36.213.

NO

No

None

NO

No

None

Indicates the ID of the RLC/PDCP parameter group.

YES

YES

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the PDCP NO discard timer.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the RLC transmission mode. Only the AM and NO UM modes are available.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the UEspecific maximum number of RLC ARQ retransmissions, namely the maximum number of AM PDU NO retransmissions. When the number of retransmissions reaches the value of this parameter, RRC connection reestablishment is initiated.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the eNodeB-specific maximum number of RLC ARQ retransmissions, namely the maximum number of AM PDU NO retransmissions. When the number of retransmissions reaches the value of this parameter, RRC connection reestablishment is initiated.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the UEspecific data volume threshold of PDUs to trigger polling. When the transmitted data NO volume reaches the value of this parameter, the Poll flag is set in the PDU header.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the eNodeB-specific data volume threshold of PDUs to trigger polling. When the NO transmitted data volume reaches the value of this parameter, the Poll flag is set in the PDU header.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the UEspecific number of PDUs to trigger polling. When the transmitted number NO of PDUs reaches the value of this parameter, the Poll flag is set in the PDU header.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the eNodeB-specific number of PDUs to trigger polling. When the transmitted number NO of PDUs reaches the value of this parameter, the Poll flag is set in the PDU header.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the Polling PDU NO retransmission timer for the UE.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the Polling PDU NO retransmission timer for the eNodeB.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the UE-specific timer for prohibiting NO status reporting from the receiver in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the eNodeBspecific timer for NO prohibiting status reporting from the receiver in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the UE-specific timer for reordering NO at the receiver in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the eNodeBspecific timer for NO reordering at the receiver in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of a PDCP sequence number NO of a UL DRB in RLC UM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of a UL RLC sequence number NO in UM. The length is permanently 10 bits in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of a DL RLC sequence number NO in UM. The length is permanently 10 bits in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the UE-specific timer for reordering NO at the receiver in UM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the length of the eNodeBspecific timer for NO reordering at the receiver in UM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates whether a PDCP status report NO is required upon handover in AM.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the QoS Class Identifier (QCI) of an EPS bearer. Different QCIs represent different QoS specifications such as the packet delay YES budget, packet error loss rate, and resource type (whether the service is a GBR service or not). For details, see Table 6.1.7 in 3GPP TS 23.203. Indicates the weight factor used in the calculation of NO connection priorities during uplink scheduling. Indicates the weight factor used in the calculation of NO connection priorities during downlink scheduling.

YES

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

NO

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

NO

No

LOFD-001015 / TDLOFD-001015 LOFD-00101502 / TDLOFD-00101502

Indicates the uplink minimum guaranteed bit rate NO of the non-GBR service.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the downlink minimum guaranteed bit rate of the non-GBR service.

NO

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the preallocation weight. The pre-allocation weight of a UE is the pre-allocation weight of services carried by the highest-priority logical channel. If services carried by highest-priority logical channels have different preallocation weights, the UE takes the highest preNO allocation weight. When resources are insufficient, preallocation weights affect the preallocation probabilities of users. The preallocation probability has a positive correlation with the preallocation weight. This parameter is QCI-specific.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the ID of a parameter group NO related to inter-RAT handover.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023 LOFD-001043 / TDLOFD-001043 LOFD-001045 / TDLOFD-001045 LOFD-001044 / TDLOFD-001044 LOFD-001046 / TDLOFD-001046 LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035

Indicates the ID of an RLC/PDCP parameter group.

NO

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the prioritized bit rate of the logical channel. The UE scheduler guarantees prioritized bit rates NO of logical channels in descending order of logical channel priority. For details, see 3GPP TS 36.321.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the priority of the logical channel. The UE scheduler guarantees prioritized bit rates of logical channels in an ascending order of logical channel priorities. NO Resources are allocated in an ascending order of logical channel priorities after the prioritized bit rates of all services are guaranteed. For details, see 3GPP TS 36.321.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates whether to enable flow control NO for the QCI.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103 LOFD-00301202 / TDLOFD-00301202 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the default Doppler shift level. This is the default parameter used when Doppler shift NO measurement is not required. This parameter is unavailable in this version.

NO

No

LOFD-00101502 / TDLOFD-00101502

Indicates the type of adaptive beamforming and MIMO (BFMIMO) for a multi-antenna eNodeB. The values are described as follows: NO_ADAPTIVE: A fixed BFMIMO transmission mode is used. That is, transition between BFMIMO transmission modes is not supported. NO TxD_BF_ADAPTIV E: The transmission mode changes adaptively between TM2 and TM7 or between TM2 and TM8, depending on the protocol release with which UEs comply. MIMO_BF_ADAPTI VE: The transmission mode changes adaptively between TM2, TM3, and TM7 or between TM2, TM3,

NO

No

LBFD-002017 / TDLBFD-002017 LOFD-001001 / TDLOFD-001001 LOFD-001003 / TDLOFD-001003 TDLOFD-009003

Indicates the fixed beamforming and MIMO (BFMIMO) transmission mode configured by a multi-antenna eNodeB for UEs. This parameter is valid only when BfMimoAdaptiveSwi tch is set to NO_ADAPTIVE. There are five values. TM2: Transmission NO mode 2 is always used for UEs. TM3: Transmission mode 3 is always used for UEs. TM7: Transmission mode 7 is always used for UEs. TM8: Transmission mode 8 is always used for UEs. TM4: Transmission mode 4 is always used for UEs.

NO

No

LBFD-002017 / TDLBFD-002017 LOFD-001001 / TDLOFD-001001 LOFD-001003 / TDLOFD-001003 TDLOFD-009003

Indicates whether to enable or disable CQI reporting period adaptation. NO This parameter is valid only for FDD cells.

NO

No

LBFD-002025 / TDLBFD-002025

Indicates the fixed CQI reporting period. A fixed CQI reporting period is used when CQI NO reporting period adaptation is disabled. This parameter is valid only for FDD cells.

NO

No

LBFD-002025 / TDLBFD-002025

Indicates the type of adaptive MIMO for a multi-antenna eNodeB. The values are described as follows: NO_ADAPTIVE: A fixed MIMO transmission mode is used. That is, transition between MIMO transmission modes is not supported. OL_ADAPTIVE: open-loop adaptive NO MIMO transmission mode. UEs report RANK and CQI values but do not report PMI values to the eNodeB. CL_ADAPTIVE: closed-loop adaptive MIMO transmission mode. UEs report RANK, CQI, and PMI values to the eNodeB. OC_ADAPTIVE: UEs switch between the open-loop and

NO

No

LOFD-001001 / TDLOFD-001001 LOFD-001003 / TDLOFD-001003

Indicates the fixed MIMO mode for a multi-antenna eNodeB. This parameter is valid only when MimoAdaptiveSwitc h is set to NO_ADAPTIVE. There are four values. TM2: Transmission mode 2 is permanently applied NO to UEs. TM3: Transmission mode 3 is permanently applied to UEs. TM4: Transmission mode 4 is permanently applied to UEs. TM6: Transmission mode 6 is permanently applied to UEs.

NO

No

LOFD-001001 / TDLOFD-001001 LOFD-001003 / TDLOFD-001003

Indicates whether to enable or disable NO SRS period adaptation.

NO

No

LBFD-002025 / TDLBFD-002025

Indicates the fixed SRS period. A fixed SRS period is used NO when SRS period adaptation is disabled.

NO

No

LBFD-002025 / TDLBFD-002025

Indicates the QoS class identifier (QCI). QCI 1 indicates voice services. QCI 2 indicates video (live streaming) services. QCI 3 indicates realtime gaming services. QCI 4 indicates YES video (buffered streaming) services. QCI 5 indicates IMS signaling. QCI 7 indicates voice, video, and interactive gaming services. QCIs 6, 8, and 9 indicate video services and TCPbased services.

YES

No

None

Indicates the length of the timer for periodic transmission of buffer status reports (BSRs). BSRs are sent periodically or as triggered by events. Periodic NO transmission of BSRs uses the timer specified by this parameter. When the timer expires, a BSR is sent. After the BSR is sent, the timer is restarted.

NO

No

None

Indicates the length of the BSR retransmission NO timer. This timer is started after a BSR is sent.

NO

No

None

Indicates the measurement gap pattern. The eNodeB defines the measurement gaps for UEs in connected mode. During the measurement gaps, a UE measures the signal quality of the cells on a specific frequency. NO There are two gap patterns: pattern 1 and pattern 2. In pattern 1, the gap width is 6 ms and the repetition period is 40 ms. In pattern 2, the gap width is 6 ms and the repetition period is 80 ms. For details, see 3GPP TS 36.331. Indicates the upperlayer filtering coefficient for RSRP measurements on EUTRAN. A large value of this parameter indicates a strong smoothing NO effect and high resistance to fast fading, but it weakens the tracing capability towards varying signals. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201802 / TDLBFD-00201802 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the upperlayer filtering coefficient for RSRQ measurements on EUTRAN. A larger value of this parameter indicates a stronger NO smoothing effect and higher resistance to fast fading, but it may weaken the tracing capability towards varying signals. For details, see 3GPP TS 36.331. Indicates the L3 filtering coefficient used for the measurement quantity in interRAT measurements of GERAN. A great value of this parameter indicates NO a strong smoothing effect and a high anti-fast-fading capability, but a low signal change tracing capability. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001034 / TDLOFD-001034

Indicates whether the measurement threshold needs to be set. If this parameter is set to CFG, the SMeasure NO parameter needs to be set. If this parameter is set to NOT_CFG, the SMeasure parameter does not need to be set.

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802 LOFD-001023 / TDLOFD-001023 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022

Indicates the threshold below which measurements on neighboring cells are started. If the signal quality of the serving cell exceeds this threshold, the UE is not required to perform intrafrequency, interfrequency, or interRAT NO measurements, leading to reduced power consumption. The value -141 does not take effect, and is reserved for backward compatibility. If this parameter is set to 141, the value -140 is used as the threshold in implementation. Indicates whether mobility-based cell handover measurement parameters need to be set. If this parameter is set to CFG, the system supports setting of mobilitybased handover NO measurement parameters. If this parameter is set to NOT_CFG, the system does not support setting of mobility-based handover measurement parameters.

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022

NO

No

LOFD-001007 / TDLOFD-001007 LOFD-001008 / TDLOFD-001008

Indicates the cycle during which evaluations of the UE medium and high mobility states in RRC_CONNECTE D mode are performed. It is one of the key parameters in deciding on a UE's mobility state. If this parameter is set to NO a small value, switchings among mobility states are frequent and the decision precision is relatively low. If this parameter is set to a large value, switchings among mobility states are not frequent and the decision precision is relatively high. Indicates the cycle during which evaluations of the UE normal mobility state in RRC_CONNECTE D mode are performed. It is one of the key parameters in deciding on a UE's mobility state. If this parameter is set to NO a small value, switchings among mobility states are frequent and the decision precision is relatively low. If this parameter is set to a large value, switchings among mobility states are not frequent and the decision precision is relatively high.

NO

No

LOFD-001007 / TDLOFD-001007 LOFD-001008 / TDLOFD-001008

NO

No

LOFD-001007 / TDLOFD-001007 LOFD-001008 / TDLOFD-001008

Indicates the handover number threshold used in the UE medium mobility state evaluation. If the number of handovers performed during a period of time specified by the NO TcrMaxConnMode parameter exceeds the value of this parameter, the UE is considered to be in medium mobility state and its handover-related parameters are adjusted. Indicates the handover number threshold used in the UE high mobility state evaluation. If the number of handovers performed during a period of time specified by the NO TcrMaxConnMode parameter exceeds the value of this parameter, the UE is considered to be in high mobility state and its handover-related parameters are adjusted.

NO

No

LOFD-001007 / TDLOFD-001007

NO

No

LOFD-001007 / TDLOFD-001007 LOFD-001008 / TDLOFD-001008

Indicates the scaling factor for the time-to-trigger defined for mediummobility UEs. For a UE in medium mobility, the time-to- NO trigger used in event evaluation is multiplied by this scaling factor, to facilitate triggering of the handover. Indicates the scaling factor for the time-to-trigger defined for highmobility UEs. For a UE in high mobility, the time-to-trigger NO used in event evaluation is multiplied by this scaling factor, to facilitate triggering of the handover. Indicates the filtering coefficient for RSCP measurements on UTRAN. A large value of this parameter indicates a strong smoothing NO effect and high resistance to fast fading, but it weakens the tracing capability towards varying signals. For details, see 3GPP TS 36.331.

NO

No

LOFD-001007 / TDLOFD-001007

NO

No

LOFD-001007 / TDLOFD-001007 LOFD-001008 / TDLOFD-001008

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001033 / TDLOFD-001033

Indicates the upperlayer filtering coefficient for Ec/No measurements on UTRAN. A large value of this parameter indicates a strong smoothing NO effect and high resistance to fast fading, but it weakens the tracing capability towards varying signals. For details, see 3GPP TS 36.331.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001033 / TDLOFD-001033

Indicates the maximum number of cells to be included in the measurement report after an inter-RAT handover event or a NO periodic inter-RAT measurement for ANR purposes is triggered. For details, see 3GPP TS 36.331.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001021 LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the number of periodical measurement reports to be sent after an inter-RAT handover event is triggered. It is used NO to prevent the impact of measurement report loss and internal processing failure on the handover. For details, see 3GPP TS 36.331.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001021 LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001043 / TDLOFD-001043 LOFD-001046 / TDLOFD-001046

Indicates the interval at which periodical measurement reports are sent after the event for the handover to GERAN is triggered. For details, see 3GPP TS 36.331.

NO

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001046 / TDLOFD-001046

Indicates the quantity to be included in the measurements for handovers to UTRAN. The RSCP values are relatively stable, while the Ec/No values may vary with the network load. The value NO UTRAN_BOTH applies only to UEs complying with R10. For UEs complying with R8 or R9, the value UTRAN_BOTH takes the same effect as the value UTRAN_RSCP. For details, see 3GPP TS 23.003.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the interval at which periodical measurement reports are sent NO after the event for the handover to UTRAN is triggered. For details, see 3GPP TS 36.331.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001043 / TDLOFD-001043

Indicates the measurement quantity required for the inter-RAT NO handover to CDMA2000 1xRTT. For details, see 3GPP TS 36.331.

NO

No

LOFD-001021

Indicates the interval at which periodical measurement reports are sent after the event for NO the handover to CDMA2000 1xRTT is triggered. For details, see 3GPP TS 36.331.

NO

No

LOFD-001021

Indicates the measurement quantity required for the inter-RAT NO handover to CDMA2000 HRPD. For details, see 3GPP TS 36.331.

NO

No

LOFD-001021

Indicates the interval at which periodic reports are sent to the eNodeB after the triggering condition of the NO event for inter-RAT handover to CDMA2000 HRPD is met. For details, see 3GPP TS 36.331.

NO

No

LOFD-001021

Indicates the quantity used to evaluate the triggering condition for the inter-RAT measurement event A1 or A2. The values are RSRP, RSRQ and BOTH. The measured RSRP values are stable, varying little with the load, and therefore there is little signal NO fluctuation. The measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. By default, the reporting quantity for the inter-RAT handover event is BOTH, that is, both RSRP and RSRQ. For details, see 3GPP TS 36.331.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001021 LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the type of the inter-RAT handover event. This parameter can be set to EventB1 NO or EventB2. The default value is EventB1. For details, see 3GPP TS 36.331.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001021 LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022

Indicates the maximum number of cells to be included in the measurement report after an intra-RAT inter-frequency or intra-RAT intrafrequency NO measurement event for handover purposes or a periodic intra-RAT measurement for ANR purposes is triggered. For details, see 3GPP TS 36.331. Indicates the number of periodical measurement reports to be sent after an event for the intra- or interfrequency handover within the E-UTRAN NO is triggered. It is used to prevent the impact of measurement report loss and internal processing failure on the handover. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802 LOFD-001032 / TDLOFD-001032

Indicates the quantity used to evaluate the triggering condition for the intrafrequency handover event. The quantity can be RSRP or RSRQ. The measured RSRP values are stable, varying little NO with the load, and therefore there is little signal fluctuation. The measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801

Indicates the quantity to be included in the measurement report for the intrafrequency handover event. The quantity can be RSRP, RSRQ, or both. The measured RSRP values are stable, varying little with the load, and therefore there is little signal fluctuation. The NO measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. Even when this parameter is set to BOTH, the eNodeB triggers a handover based on the setting of the IntraFreqHoA3Trig Quan parameter. For details, see 3GPP TS 36.331. Indicates the interval between periodic measurement reports that are sent after an intrafrequency handover is triggered. The value of this NO parameter is also used as the interval between A3-related inter-frequency measurement reports. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801

NO

No

LBFD-00201801 / TDLBFD-00201801 LOFD-001032 / TDLOFD-001032

Indicates the quantity to be included in the measurement report for the interfrequency handover event. The quantity can be RSRP, RSRQ, or both. The measured RSRP values are stable, varying little with the load, and therefore there is little signal fluctuation. The NO measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. After an inter-frequency handover event is triggered, the default reporting quantity is BOTH, that is, both RSRP and RSRQ. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201802 / TDLBFD-00201802 LOFD-001032 / TDLOFD-001032

Indicates the interval at which periodical measurement reports are sent NO after an interfrequency handover event is triggered. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201802 / TDLBFD-00201802 LOFD-001032 / TDLOFD-001032

Indicates the quantity used in the evaluation for interfrequency measurement event A1 or A2. The quantity can be RSRP, RSRQ, or both. The measured RSRP values are stable, varying little with the load, and NO therefore there is little signal fluctuation. The measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. For details, see 3GPP TS 36.331. Indicates the triggering quantity for frequencypriority-based interfrequency measurement events A1 and A2. The quantity can be either RSRP or RSRQ. The measured RSRP values are stable, NO varying little with the load, and therefore there is little signal fluctuation. The measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. For details, see 3GPP TS 36.331. Indicates the triggering quantity for frequencypriority- and loadNO based interfrequency handover event A4.

NO

No

LBFD-00201802 / TDLBFD-00201802

NO

No

LBFD-00201802 / TDLBFD-00201802

NO

No

LBFD-00201802 / TDLBFD-00201802

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the time-totrigger for event B1 that is used in CS fallback to UTRAN. When CS fallback to UTRAN is applicable, this parameter is set for UEs and used in the evaluation of whether to trigger event B1. When detecting that the signal quality in at least one UTRAN cell meets the entering condition, NO the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event

YES

No

LBFD-001001 / TDLBFD-001001

NO

No

LOFD-001033 / TDLOFD-001033

Indicates the time-totrigger for event B1 that is used in CS fallback to GERAN. When CS fallback to GERAN is applicable, this parameter is set for UEs and used in the evaluation of whether to trigger event B1. When detecting that the signal quality in at least one GERAN cell meets the entering condition, NO the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps decrease the number of occasionally triggered event

NO

No

LOFD-001034 / TDLOFD-001034

Indicates the time-totrigger for event B1, which is used in CS fallback to CDMA2000. When CS fallback to CDMA2000 is applicable, this parameter is set for UEs and used in the evaluation of whether to trigger event B1. When detecting that the signal quality in at least one CDMA2000 cell NO meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously meets the entering condition during the time-to-trigger. This parameter helps reduce the number of occasionally triggered event

NO

No

LOFD-001035

Indicates the RSCP threshold for event B1, which is used in CS fallback to UTRAN. When CS fallback to UTRAN is applicable, this parameter is set for UEs and used in the evaluation about whether to trigger event B1. This parameter indicates the RSCP requirement for the UTRAN cells to be NO included in the measurement report. A UE sends a measurement report related to event B1 to the eNodeB when the RSCP in at least one UTRAN cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP TS 36.331.

NO

No

LOFD-001033 / TDLOFD-001033

Indicates the Ec/No threshold for event B1, which is used in CS fallback to UTRAN. When CS fallback to UTRAN is required, this parameter is set for UEs and used in the evaluation about whether to trigger event B1. This parameter indicates the Ec/No requirement for the UTRAN cells to be included in the NO measurement report. A UE sends a measurement report related to event B1 to the eNodeB when the Ec/No in at least one UTRAN cell exceeds this threshold and other triggering conditions are met. For a cell with large signal fading variance, set this parameter to a large value to prevent Indicates the RSSI threshold for event B1 that is used in CS fallback to GERAN. A UE sends a measurement report related to event B1 to the eNodeB NO when the RSSI in at least one GERAN cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP TS 36.331.

NO

No

LOFD-001033 / TDLOFD-001033

NO

No

LOFD-001034 / TDLOFD-001034

Indicates the pilot strength threshold related to event B1, which is used in CS fallback to CDMA2000. A UE sends a measurement report related to event B1 to the eNodeB NO when the pilot strength in at least one CDMA2000 cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP TS 36.331. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LOFD-001035

YES

No

LBFD-001001 / TDLBFD-001001

Indicates whether to configure the NO access barring information.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the emergency call barring status of access class 10, indicating whether UEs of access class 10 can initiate emergency calls. If this parameter is set to BOOLEAN_TRUE, UEs of access classes 0 to 9 or those without IMSIs cannot initiate emergency calls. If this parameter is set NO to BOOLEAN_FALSE, UEs of access classes 0 to 9 and those without IMSIs can initiate emergency calls. A UE in access classes 11 to 15 cannot initiate emergency calls only when its access class and access class 10 are both barred. If its access class or access class 10 is

NO

No

LBFD-002028 / TDLBFD-002028

Indicates whether to configure the access barring NO information for mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the access probability factor for mobileoriginated calls. A mobile-originated call is granted access if the random number generated by the UE is smaller than this access NO probability factor; otherwise, the access request is rejected. If this parameter is set to P00, all mobileoriginated calls initiated by UEs of access class 11 to access class 15 are granted access.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the average access barring duration for NO mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the mobileoriginated call barring status of access class 11, indicating whether UEs of access class 11 can initiate mobile-originated calls. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 11 cannot initiate mobile-originated calls. If this parameter is set to BOOLEAN_FALSE, UEs of access class 11 can initiate mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the mobileoriginated call barring status of access class 12, indicating whether UEs of access class 12 can initiate mobile-originated calls. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 12 cannot initiate mobile-originated calls. If this parameter is set to BOOLEAN_FALSE, UEs of access class 12 can initiate mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the mobileoriginated call barring status of access class 13, indicating whether UEs of access class 13 can initiate mobile-originated calls. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 13 cannot initiate mobile-originated calls. If this parameter is set to BOOLEAN_FALSE, UEs of access class 13 can initiate mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the mobileoriginated call barring status of access class 14, indicating whether UEs of access class 14 can initiate mobile-originated calls. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 14 cannot initiate mobile-originated calls. If this parameter is set to BOOLEAN_FALSE, UEs of access class 14 can initiate mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the mobileoriginated call barring status of access class 15, indicating whether UEs of access class 15 can initiate mobile-originated calls. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 15 cannot initiate mobile-originated calls. If this parameter is set to BOOLEAN_FALSE, UEs of access class 15 can initiate mobile-originated calls.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates whether to configure the access barring NO information for signaling.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the access probability factor for signaling. Signaling from a UE is granted access if the random number generated by the UE is smaller than this access probability factor; NO otherwise, the access request is rejected. If this parameter is set to P00, signaling from UEs of access class 11 to access class 15 is granted access.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the average access NO barring duration for signaling.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the signaling barring status of access class 11, indicating whether UEs of access class 11 can initiate signaling access. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 11 cannot initiate signaling access. If this parameter is set to BOOLEAN_FALSE, UEs of access class 11 can initiate signaling access. Indicates the signaling barring status of access class 12, indicating whether UEs of access class 12 can initiate signaling access. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 12 cannot initiate signaling access. If this parameter is set to BOOLEAN_FALSE, UEs of access class 12 can initiate signaling access.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the signaling barring status of access class 13, indicating whether UEs of access class 13 can initiate signaling access. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 13 cannot initiate signaling access. If this parameter is set to BOOLEAN_FALSE, UEs of access class 13 can initiate signaling access. Indicates the signaling barring status of access class 14, indicating whether UEs of access class 14 can initiate signaling access. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 14 cannot initiate signaling access. If this parameter is set to BOOLEAN_FALSE, UEs of access class 14 can initiate signaling access.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the signaling barring status of access class 15, indicating whether UEs of access class 15 can initiate signaling access. If this parameter is set to NO BOOLEAN_TRUE, UEs of access class 15 cannot initiate signaling access. If this parameter is set to BOOLEAN_FALSE, UEs of access class 15 can initiate signaling access. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates whether the cell is barred. If the cell is barred, the UE cannot camp on the serving NO cell. During cell reselection, the serving cell is not selected as a candidate cell.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

YES

No

LBFD-001001 / TDLBFD-001001

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether the cell is reserved for future extension. If the cell is reserved, whether a UE can access the cell depends on the access class of the UE and its serving PLMN. Details are described as follows: (1) A UE of access class 11 or 15 treats the cell as a candidate if the UE is served by its home PLMN NO (HPLMN) or equivalent home PLMN (EHPLMN); (2) A UE of access class 11 or 15 treats the cell as a barred cell if it is not served by its HPLMN or EHPLMN; (3) A UE of an access class within the two ranges of 0-9 and 12-14 treats the cell as a barred cell. In this version, the parameter still Indicates whether the cell can initiate the intra-frequency cell reselection when the cell is barred. NOT_ALLOWED means that the UE NO cannot initiate the intra-frequency cell reselection, and ALLOWED means that the UE can initiate the intrafrequency cell reselection.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether the PLMN broadcast sequence is fixed or periodically rotates, corresponding to the normal mode or round Robin mode. If certain cells in the live network are in RAN sharing with common carrier mode and at least one cell uses the round Robin mode, ANR must be NO disabled for all cells in the network. If ANR is enabled for a cell that is not in RAN sharing with common carrier mode, the cell may experience failures in handing over UEs to an ANRestablished neighboring cell that is in RAN sharing with common carrier mode.

NO

No

LBFD-001001 LBFD-002009 LBFD-00201803

Indicates the changing period of cell PLMN.

NO

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the tracking area identity of the cell, which uniquely identifies an operator within a cell.

YES

YES

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether the cell is reserved for operator use. If this parameter is set to CELL_RESERVED _FOR_OP, the cell is reserved for operator use. UEs of AC11 or AC15 in their HPLMN or EHPLMN can consider this cell as a candidate cell for cell selection or reselection. UEs of AC11 or AC15 NO outside their HPLMN/EHPLMN and UEs of AC09/AC12-14 consider this cell as a barred cell during cell selection or reselection. If this parameter is set to CELL_NOT_RESE RVED_FOR_OP, the cell is not reserved for operator use. All UEs can consider this cell as a Indicates the percentage of RBs occupied by the operator on the PUSCH when RAN sharing is enabled at the eNodeB and the cell-level switch of RAN sharing is turned on. When the data volume is NO sufficiently large, the percentage of RBs occupied by each operator will reach the preset value. Modifications on this parameter affect operators' percentages of RBs.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the percentage of RBs occupied by the operator on the PDSCH when RAN sharing is enabled at the eNodeB and the cell-level switch of RAN sharing is turned on. When the data volume is NO sufficiently large, the percentage of RBs occupied by each operator will reach the preset value. Modifications on this parameter affect operators' percentages of RBs. Indicates the operator index that is broadcast in the cell system information.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

NO

Yes

None

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the hysteresis for cell reselection when RSRP values are used in the evaluation. This parameter must be set based on the slow fading characteristic of the area covered by the cell. The greater the NO slow fading variance is, the larger the value of this parameter must be set to. A larger value of the hysteresis results in a larger boundary of the serving cell and a higher probability of cell reselection to neighboring cells.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the parameters related to speedNO dependent cell reselection.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the duration in which the mobility status of the UE is evaluated. This parameter is one of the key parameters in deciding on the UE mobility. A smaller value of this NO parameter may lead to more frequent switching among mobility status and lower decision accuracy. A larger value of this parameter leads to the opposite effect.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the extra duration required in the evaluation before the UE can enter the normalmobility state. This parameter can prevent UEs from frequently switching from the high- or medium-mobility state to the normalmobility state, and is one of the key parameters in NO deciding on the UE mobility. A larger value of this parameter leads to a lower probability of transition from the high- or mediummobility state to the normal-mobility state but higher decision accuracy. A smaller value of this parameter leads to the opposite effect.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the threshold for a UE to enter the medium mobility state. Based on the number of cell reselections, this parameter is one of the key parameters in determining the mobility state of the UE. During the UE mobility evaluation, if the number of reselections is above or equal to the value of this NO parameter and below than the value of NCellChangeHigh, the UE enters the medium mobility state. A smaller value of this parameter results in a higher probability of a UE entering the medium mobility state. A larger value of this parameter leads to a lower probability.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the threshold for a UE to enter the high mobility state. Based on the number of cell reselections, this parameter is one of the key parameters in determining the mobility state of the UE. During the UE mobility evaluation, if the number of cell reselections is NO above or equal to the value of this parameter, the UE enters the high mobility state. A smaller value of this parameter results in a higher probability of a UE entering the high mobility state. A larger value of this parameter leads to a lower probability.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the additional hysteresis applied to Qhyst for mediummobility UEs. For example, the value DB_6_Q_HYST_SF _MEDIUM indicates NO -6 dB additional hysteresis applied to Qhyst for mediummobility UEs, and DB_4_Q_HYST_SF _MEDIUM indicates -4 dB additional hysteresis.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the additional hysteresis applied to Qhyst for highmobility UEs. For example, the value DB_6_Q_HYST_SF _HIGH indicates -6 NO dB additional hysteresis applied to Qhyst for highmobility UEs, and DB_4_Q_HYST_SF _HIGH indicates -4 dB additional hysteresis.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the measurement triggering threshold NO for reselection to inter-frequency or inter-RAT cells.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the measurement triggering threshold for reselection to inter-frequency or inter-RAT cells. The step is 2 dB. If the cell reselection priority of a frequency or RAT is higher than that of the serving frequency, the UEs always start interfrequency or interRAT measurements. NO If the cell reselection priority of a frequency is lower than or equal to that of the serving frequency or if the cell reselection priority of an RAT is lower than that of the serving frequency, the UEs start interfrequency or interRAT measurements only when the value of Cell selection RX level value (dB) is

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the threshold used in the evaluation of reselection to a cell on a lower priority EUTRAN frequency or on an inter-RAT frequency. Cell reselection to a cell on a lower priority EUTRAN frequency or on an inter-RAT NO frequency is performed if no cell on the serving frequency or on a higher priority EUTRAN frequency fulfills criteria 1 for inter-frequency and inter-RAT reselections. For details, see 3GPP TS 36.304. Indicates the cell reselection priority of the serving frequency. 0 indicates the lowest priority. The value of this parameter must be determined together with the priorities of other NO frequencies during the network planning. Frequencies used for different RATs must be assigned different cell reselection priorities.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the minimum required receive level used NO in intra-frequency EUTRA cell reselection.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to configure the maximum TX power of the UE in the intra-frequency neighboring cell. When the parameter is set to NO CFG, the maximum TX power of the UE is configured. When the parameter is set to NOT_CFG, the maximum TX power of the UE is not configured.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the maximum TX power of the UE in the cell. If this parameter is NO not included in the SIB3, the UE uses the maximum TX power.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the measurement triggering threshold NO for reselection to intra-frequency cells.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the measurement triggering threshold for reselection to intra-frequency cells. The step is 2 dB. The UEs start intraNO frequency measurements only if the value of Cell selection RX level value (dB) is lower than or equal to the value of this parameter.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the NO measurement bandwidth.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the measurement bandwidth on the serving frequency on which the UE camps. It is used in intra-frequency measurements for cell reselection and NO those by UEs in RRC_CONNECTE D mode. This parameter is optional; if it is not set, the downlink bandwidth of the serving cell is used by default. Indicates the cell reselection duration of the E-UTRAN. When the signal quality of the new cell is better than the serving cell all the time and the UE stays in the current serving cell for more than 1s, the UE is initiating cell reselection request to the new cell. The smaller the parameter is, the NO easier the cell reselection from the serving cell is triggered, and the more possibly that the pingpong reselection occurs. The bigger the parameter is, the more difficult the cell reselection from the serving cell is triggered, and the less possibly that the pingpong reselection occurs.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the scaling parameters for NO speed-dependent cell reselection within E-UTRAN.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the scaling factor applied to TReselEutra for medium-mobility UEs. The actual duration of cell NO reselection for medium-mobility UEs to E-UTRAN is equal to the product of TReselEutra and TReselEutranSfMe dium.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the scaling factor applied to TReselEutran for high-mobility UEs. The actual duration of cell reselection of NO high-mobility UEs to E-UTRAN is equal to TReselEutran multiplied by TReselEutranSfHig h.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the information related to MBSFN and TDD UL/DL configurations of intra-frequency neighboring cells of the serving cell. The value 00 indicates that some neighboring cells have the same MBSFN subframe configuration as the serving cell. The value 01 indicates that none NO of the neighboring cells is configured with MBSFN subframes. The value 10 indicates that the MBSFN subframe configurations of all neighboring cells are the same as or subsets of that of the serving cell. The value 11 indicates that some neighboring cells have different ULDL configurations Indicates whether the intra-frequency neighboring cells are configured with the 2TX antenna. Set this parameter to TRUE when all the intra-frequency neighboring cells NO are configured with the 2TX antenna. Set this parameter to FALSE when one of the intrafrequency neighboring cells is not configured with the 2TX antenna.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the RSRQ threshold for starting intrafrequency measurements. It determines the probability of NO triggering cell reselection to an intra-frequency neighboring cell. For details, see 3GPP TS 36.304. Indicates the RSRQ threshold for starting interfrequency or interRAT measurements. It determines the probability of NO triggering cell reselection to an inter-frequency or inter-RAT neighboring cell. For details, see 3GPP TS 36.304.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the RSRQ threshold for NO reselection to cells on lower-priority frequencies.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the RSRQ threshold for cell reselection to cells on lower-priority frequencies. It determines the probability of triggering cell NO reselection to interfrequency or interRAT neighboring cells on lowerpriority frequencies. For details, see 3GPP TS 36.304. Indicates whether to set the RX level of an intra-frequency neighboring cell, NO which is required for it to become a candidate for cell reselection.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the minimum RX level of an intrafrequency neighboring cell, which is required for it to become a candidate for cell reselection. It NO determines the probability of triggering cell reselection to an intra-frequency neighboring cell. For details, see 3GPP TS 36.304.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates whether to configure the CDMA2000 system NO time information. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the network synchronization status. If this parameter is set to BOOLEAN_TRUE, the E-UTRAN and the CDMA2000 RAN are synchronized NO without drifts. If this parameter is set to BOOLEAN_FALSE, the E-UTRAN and the CDMA2000 RAN are not synchronized. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 LBFD-002009 LBFD-00201803

Indicates whether to set the search window size. If this parameter is set to CFG, the cell is configured with the search window. If NO the parameter is set to NOT_CFG, the cell is not configured with the search window. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the size of the CDMA2000 search window, and can be used to assist in searching NO for the neighboring pilots. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the HRPD parameters. If this parameter is set to CFG, the cell is configured with the NO HRPD parameters. If the parameter is set to NOT_CFG, the cell is not configured with the HRPD parameters.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the parameters related to cell reselection to CDMA2000 HRPD. If the parameter is set to CFG, the cell is configured with the parameters related to cell NO reselection to CDMA2000 HRPD. If the parameter is set to NOT_CFG, the cell is not configured with the parameters related to cell reselection to CDMA2000 HRPD.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether pre-registration with CDMA2000 HRPD is allowed when the UE does not have a valid preregistration. If the parameter is set to BOOLEAN_TRUE, the UE is allowed to NO perform the preregistration. If the parameter is set to BOOLEAN_FALSE, the UE is not allowed to perform the pre-registration. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the ID of the pre-registration CDMA2000 HRPD zone. This parameter is used to control the reregistration of the NO UE and is valid only when preregistration is allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 LBFD-002009 LBFD-00201803

Indicates whether secondary preregistration zone ID 0 needs to be set. The value CFG indicates that secondary preregistration zone ID NO 0 exists, and the value NOT_CFG indicates that secondary preregistration zone ID 0 does not exist. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates secondary pre-registration zone ID 0. It is used to control the reNO registration of the UE. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether secondary preregistration zone ID 1 needs to be set. The value CFG indicates that secondary preregistration zone ID NO 1 exists, and the value NOT_CFG indicates that secondary preregistration zone ID 1 does not exist. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates secondary pre-registration zone ID 1. It is used to control the reNO registration of the UE. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the duration used in cell reselection to CDMA2000 HRPD. The UE initiates reselection to a CDMA2000 HRPD cell when all the following conditions are met: (1) The signal quality in the serving cell is continuously lower than its low-priority reselection threshold during the time; (2) The signal NO quality in the CDMA2000 HRPD cell is continuously higher than its lowpriority reselection threshold during the time; and (3) The UE camps on the current serving cell for more than 1s. A smaller value of this parameter indicates a higher probability of initiating cell reselection but a higher probability of ping-pong

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the speeddependent scaling parameters related to cell reselection to CDMA2000 HRPD. If this parameter is set to CFG, the system supports the speed-dependent NO scaling parameters. If this parameter is set to NOT_CFG, the system does not support the speeddependent scaling parameters. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the scaling factor applied to TReselCdmaHrpd for high-mobility UEs. The actual duration of cell reselection of highmobility UEs to CDMA2000 HRPD is equal to TReselCdmaHrpd multiplied by NO TReselCdmaHrpdSf High. The value T_RESEL_SF_0DO T25 means a scaling factor of 0.25, T_RESEL_SF_0DO T5 means 0.5, and so on. For details, see 3GPP TS 36.331. Indicates the scaling factor applied to TReselCdmaHrpd for medium-mobility UEs. The actual duration of cell reselection of medium-mobility UEs to CDMA2000 HRPD is equal to TReselCdmaHrpd multiplied by NO TReselCdmaHrpdSf Medium. The value T_RESEL_SF_0DO T25 means a scaling factor of 0.25, T_RESEL_SF_0DO T5 means 0.5, and so on. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether the parameters applicable only for interworking with CDMA2000 1xRTT need to be set. If this parameter is set to CFG, the cell needs to be NO configured with the 1xRTT parameters. If this parameter is set to NOT_CFG, the cell does not need to be configured with the 1xRTT parameters.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether registration parameters need to be set for CS fallback to CDMA2000 1xRTT. If this parameter is set to CFG, the cell needs to be configured with the registration parameters for CS NO fallback to CDMA2000 1xRTT. If this parameter is set to NOT_CFG, the cell does not need to be configured with the registration parameters for CS fallback to CDMA2000 1xRTT.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the CDMA2000 1xRTT system ID. For NO details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the CDMA2000 1xRTT network ID. For NO details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific multiple system ID storage NO is allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific multiple network ID storage NO is allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific home registration is NO allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific SID roamer registration is NO allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific NID roamer registration is NO allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific parameterchange registration NO is allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific power-up registration is NO allowed. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific registration period. For details, NO see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific registration zone. For details, NO see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the 1xRTTspecific number of registration zones to NO be retained. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the length of the 1xRTTspecific zone timer. NO For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates whether the CDMA2000 1xRTT-specific long code state needs to be set. If this parameter is set to CFG, the cell needs to be configured with the long code state. If this parameter is set to NOT_CFG, the cell does not need to be configured with the NO long code state. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the CDMA2000 1xRTTspecific long code state. For details, see 3GPP TS 36.331. In this version, the setting of this parameter is still synchronized NO between the M2000 and the eNodeB, but it is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether the parameters applicable only for cell reselection to CDMA2000 1xRTT need to be set. If this parameter is set to CFG, the cell needs to be configured with the parameters related NO to cell reselection to CDMA2000 1xRTT. If this parameter is set to NOT_CFG, the cell does not need to be configured with the parameters related to cell reselection to CDMA2000 1xRTT.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the duration used in cell reselection to NO CDMA2000 1xRTT. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether speed-dependent scaling parameters need to be set for cell reselection to CDMA2000 1xRTT. When the parameter is set to CFG, the system NO supports the speeddependent scaling parameters. When the parameter is set to NOT_CFG, the system does not support the speeddependent scaling parameters.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the scaling factor applicable to cell reselection of medium-mobility NO UEs to CDMA2000 1xRTT. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the scaling factor applicable to cell reselection of highNO mobility UEs to CDMA2000 1xRTT. For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to configure CDMA2000 1xRTT power-down NO registration. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to configure access NO class barring for CDMA2000 1xRTT.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the persistence value for access overload NO classes 0 to 9. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for access overload NO class 10. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for access overload NO class 11. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for access overload NO class 12. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for access overload NO class 13. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for access overload NO class 14. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for access overload NO class 15. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the adjustment to the access class barring factor for message transmissions. For details, see 3GPP TS 36.331.

NO

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the adjustment to the access class barring factor for autonomous registrations. For details, see 3GPP TS 36.331.

NO

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the persistence value for emergency calls and emergency messages for NO access overload classes 0 to 9. For details, see 3GPP TS 36.331.

NO

No

LBFD-001007 / TDLBFD-001007 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LOFD-001035

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the cell reselection duration of GERAN cell reselection. When the signal quality of the serving cell is lower than the low priority reselection threshold all the time and the signal of the new cell is higher than the low priority reselection threshold all the time, and the UE stays in the current serving cell for more NO than 1s, then the UE is initiating cell reselection request to the new cell. The lower the parameter is, the easier it is for the UE to initiate cell reselection. However, the PingPong reselection probability is increased. The higher the parameter is, the harder it is for the UE to initiate cell reselection. The Indicates whether to set the speeddependent scaling parameters related to cell reselection to GERAN. If this parameter is set to CFG, the system supports the NO speed-dependent scaling parameters. If this parameter is set to NOT_CFG, the system does not support the speeddependent scaling parameters.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LBFD-002018 / TDLBFD-002018

Indicates the scaling factor applied to TReselGeran for medium-mobility UEs. The actual duration of cell reselection of medium-mobility UEs to GERAN is equal to TReselGeran NO multiplied by TReselGeranSfMed ium. The value T_RESEL_SF_0DO T25 means a scaling factor of 0.25, T_RESEL_SF_0DO T5 means 0.5, and so on. Indicates the scaling factor applied to TReselGeran for high-mobility UEs. The actual duration of cell reselection of high-mobility UEs to GERAN is equal to TReselGeran NO multiplied by TReselGeranSfHigh . The value T_RESEL_SF_0DO T25 means a scaling factor of 0.25, T_RESEL_SF_0DO T5 means 0.5, and so on.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LBFD-002018 / TDLBFD-002018

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LBFD-002018 / TDLBFD-002018

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the cell reselection duration of UTRAN cell reselection. When the signal quality of the serving cell is lower than the low priority reselection threshold all the time and the signal of the new cell is higher than the low priority reselection threshold all the time, and the UE stays in the current serving cell for more NO than 1s, then the UE is initiating cell reselection request to the new cell. The lower the parameter is, the easier it is for the UE to initiate cell reselection. However, the PingPong reselection probability is increased. The higher the parameter is, the harder it is for the UE to initiate cell reselection. The

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the speeddependent scaling parameters related to cell reselection to UTRAN. If this parameter is set to CFG, the system supports the NO speed-dependent scaling parameters. If this parameter is set to NOT_CFG, the system does not support the speeddependent scaling parameters. Indicates the scaling factor applied to TReselUtran for medium-mobility UEs. The actual duration of cell reselection of medium-mobility UEs to UTRAN is equal to TReselUtran NO multiplied by TReselUtranSfMedi um. The value T_RESEL_SF_0DO T25 means a scaling factor of 0.25, T_RESEL_SF_0DO T5 means 0.5, and so on.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LBFD-002018 / TDLBFD-002018

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803 LBFD-002018 / TDLBFD-002018

Indicates the scaling factor applied to TReselUtran for high-mobility UEs. The actual duration of cell reselection of high-mobility UEs to UTRAN is equal to TReselUtran NO multiplied by TReselUtranSfHigh. The value T_RESEL_SF_0DO T25 means a scaling factor of 0.25, T_RESEL_SF_0DO T5 means 0.5, and so on. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LBFD-001001 LBFD-002009 LBFD-00201803 LBFD-002018

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the minimum required RX level for the cell to become a candidate for cell selection. This NO value is included in criteria S and used in the evaluation of cell selection. For details, see 3GPP TS 36.304.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the offset to the minimum required RX level. This value is included in criteria S and used in the evaluation of cell selection. This parameter is valid only when the cell selection is NO triggered by periodic searches for higher-priority PLMNs and the UE is served by a Visited Public Land Mobile Network (VPLMN). For details, see 3GPP TS 36.304.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates the minimum RX level of the cell. It is included in criteria S and used in the NO evaluation of cell selection. For details, see 3GPP TS 36.304.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the offset to the minimum required RX level for the cell. If this parameter is set to CFG, the NO offset is required. If this parameter is set to NOT_CFG, the offset does not need to be set. Indicates the offset to the minimum required RX level for the cell. It is included in criteria S and used in the evaluation of cell selection. This parameter is required only when the cell selection is NO triggered by periodic searches for higher-priority PLMNs and the UE is served by a Visited Public Land Mobile Network (VPLMN). For details, see 3GPP TS 36.304. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-00201803 / TDLBFD-00201803

YES

No

LBFD-001001 / TDLBFD-001001

Indicates whether the mapping from SIBs to SI messages is enabled.

NO

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 2 (SIB2). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 3 (SIB3). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 4 (SIB4). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 5 (SIB5). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 6 (SIB6). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 7 (SIB7). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 8 (SIB8). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 10 (SIB10). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the transmission period for system information block NO type 11 (SIB11). For details, see 3GPP TS 36.331.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the duration of the primary notification (PN) broadcast for NO the Earthquake and Tsunami Warning System (ETWS). Indicates the policy of processing repeated secondary notification (SN) NO broadcast for the Earthquake and Tsunami Warning System (ETWS).

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the policy of processing repeated primary notification (PN) NO broadcast for the Earthquake and Tsunami Warning System (ETWS). Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the compensation factor for path loss. It is used in UL power NO control. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the target UE transmit power for the PUCCH expected by the eNodeB on condition that NO normal demodulation can be performed. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the nominal P0 value of the PUSCH. It is used in UL power NO control. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the Delta value corresponding to PUCCH format 1. NO For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the Delta value corresponding to PUCCH format NO 1b. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the Delta value corresponding to PUCCH format 2. NO For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the Delta value corresponding to PUCCH format NO 2a. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the Delta value corresponding to PUCCH format NO 2b. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the power offset (delta value) of message 3 relative to the preamble. This NO power offset has a step size of 2. For details, see 3GPP TS 36.213.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

Indicates the local identity of the cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the length of the uplink time alignment timer for UEs in the cell. A NO UE is considered not time-aligned in the uplink if the timer expires.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the timer value of Timer 300. For details, see 3GPP TS 36.331. This timer is started when the UE sends RRCConnectionRe quest. Before the timer expires, it is NO stopped if the UE receives RRCConnectionSet up or RRCConnectionRej ect. After the timer expires, the UE directly enters the RRC_IDLE state. Indicates the length of timer 301. For details, see 3GPP TS 36.331. This timer is started when the UE sends an RRC Connection Reestablishment Request message. The timer is stopped if, before it expires, the UE receives an RRC Connection Reestablishment or NO RRC Connection Reestablishment Reject message. The timer is also stopped if the selected cell becomes an unsuitable cell. For the definition of a suitable cell, see 3GPP TS 36.331. After the timer expires, the UE enters the RRC_IDLE mode.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the length of timer 310. For details, see 3GPP TS 36.331. This timer is started when the UE detects any fault at the physical layer. The timer is stopped if the UE detects one of the following before the timer expires: (1) The physical-layer fault is rectified; (2) A handover is triggered; (3) The NO UE initiates an RRC connection reestablishment procedure. After the timer expires, the UE enters the RRC_IDLE mode if the security mode is not activated. If the security mode is activated, the UE initiates an RRC connection reestablishment procedure. Indicates the length of timer 311. For details, see 3GPP TS 36.331. This timer is started when the UE starts the RRC connection reestablishment procedure. The timer is NO stopped if, before the timer expires, the UE selects an EUTRAN or interRAT cell to camp on. After the timer expires, the UE enters the RRC_IDLE mode.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the maximum number of successive "in sync" indications received from L1.

NO

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009 LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

Indicates the maximum number of successive "out NO of sync" indications received from L1.

NO

No

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the name NO of the cell.

YES

No

None

Indicates the ID of the sector to which the cell belongs.

NO

YES

No

None

Indicates whether the cell is a closed subscriber group (CSG) cell. A CSG cell has restrictions on UE access. It broadcasts a specific CSG ID in the SIB and only those UEs of the group can access NO the CSG cell. BOOLEAN_FALSE indicates that the cell is not a CSG cell, and BOOLEAN_TRUE indicates that the cell is a CSG cell. Currently, Huawei eNodeBs do not support CSG cells. Indicates the UL cyclic prefix length of a cell. A cyclic prefix can be a common or extended cyclic prefix. An extended cyclic prefix is generally used in a complex environment with a strong multi-path effect and long NO delay. In a cell, the UL cyclic prefix length can be different from the DL one. In addition, the UL or DL cyclic prefix length of a cell must be the same as that of the cell using the same LBBP. For details, see 3GPP TS 36.211.

NO

No

LBFD-002009 / TDLBFD-002009

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-001004 / TDLBFD-001004 LBFD-00100401 / TDLBFD-00100401 LOFD-001031

Indicates the length of the DL cyclic prefix of a cell. A DL cyclic prefix can be a common or extended cyclic prefix. An extended cyclic prefix is generally used in a complex environment with a strong multi-path effect and long NO delay. In a cell, the UL cyclic prefix length can be different from the DL one. In addition, the UL or DL cyclic prefix length of a cell must be the same as that of the cell using the same LBBP. For details, see 3GPP TS 36.211. Indicates the frequency band in which the cell operates. For details about this parameter, see 3GPP TS 36.104.

NO

No

LBFD-001004 / TDLBFD-001004 LBFD-00100401 / TDLBFD-00100401 LOFD-001031

NO

YES

No

LBFD-002009 / TDLBFD-002009 LBFD-001007 / TDLBFD-001008 LBFD-001008 / TDLBFD-001009

Indicates whether to configure the UL EARFCN of the cell. For an FDD cell, if no UL EARFCN is configured, the UL EARFCN equals the NO sum of the DL EARFCN and 18000 by default. For a TDD cell, the UL EARFCN equals the DL EARFCN.

NO

No

LBFD-002009 / TDLBFD-002009

Indicates the UL EARFCN of the cell. It is optional, depending on the setting of the UL EARFCN configuration indicator (UlEarfcnCfgInd). If NO the value of this parameter is not specified, the default UL EARFCN is used, which is calculated based on the DL EARFCN. For details, see 3GPP TS 36.104. Indicates the DL EARFCN of the cell. NO For details, see the 3GPP TS 36.104.

NO

No

LBFD-002009 LBFD-001007 / TDLBFD-001008 LBFD-001008 / TDLBFD-001009

YES

No

LBFD-002009 / TDLBFD-002009 LBFD-001007 / TDLBFD-001008 LBFD-001008 / TDLBFD-001009

Indicates the UL bandwidth of the cell, which is based on the number of resource blocks (RBs). The value CELL_BW_N25 indicates a cell bandwidth of 25 RBs. The value CELL_BW_N50 indicates a cell NO bandwidth of 50 RBs. The mapping between the parameter value and the actual cell bandwidth (that is, the number of RBs) can be deduced similarly. For details, see 3GPP TS 36.104.

YES

No

LBFD-001003 / TDLBFD-001003 LBFD-002009 / TDLBFD-002009

Indicates the DL bandwidth of the cell, which is based on the number of resource blocks (RBs). The value CELL_BW_N25 indicates a cell bandwidth of 25 RBs. The value CELL_BW_N50 indicates a cell NO bandwidth of 50 RBs. The mapping between the parameter value and the actual cell bandwidth (that is, the number of RBs) can be deduced similarly. For details, see 3GPP TS 36.104. Indicates the ID of the E-UTRAN cell. The combination of this parameter and the eNodeB ID forms the E-UTRAN cell identity. The NO combination of the E-UTRAN cell identity and the PLMN identity forms the ECGI. For details, see 3GPP TS 36.413. Indicates the physical cell ID. For NO details, see 3GPP TS 36.331. Indicates the additional spectrum emission, which restricts the NO emission power of the UEs in the cell. For details, see the 3GPP TS 36.101.

YES

No

LBFD-001003 / TDLBFD-001003 LBFD-002009 / TDLBFD-002009

YES

No

LBFD-002009 / TDLBFD-002009

YES

No

LBFD-002009 / TDLBFD-002009

NO

No

LBFD-002009 / TDLBFD-002009

Indicates the active state of the cell. It consists of the NO activated and deactivated states. Indicates the administrative state, which can be NO Unblock, High block, Middle block, or Low block. Indicates the length of the timer used to determine whether to block a middleblocking-priority cell. If CellAdminState is set to CELL_MIDDLE_BL NO OCK, the cell is deactivated when no user accesses the cell during the period of time specified by this parameter. The cell is also deactivated if the timer expires. Indicates the duplex mode of the cell. CELL_FDD indicates the FDD NO mode, and CELL_TDD indicates the TDD mode.

NO

No

None

NO

No

None

NO

No

None

YES

No

LBFD-002009 / TDLBFD-002009

Indicates the ratio of UL subframes to DL subframes in a TDD NO cell. For details, see 3GPP TS 36.211.

NO

No

LBFD-002009 / TDLBFD-002009 TDLBFD-00100701 TDLOFD-00102601

Indicates the ratio of special UL subframes to special DL NO subframes in a TDD cell. For details, see 3GPP TS 36.211.

NO

No

LBFD-002009 / TDLBFD-002009 TDLBFD-00100702 TDLOFD-00102602 TDLOFD-00102603

Indicates the cell specific offset for the serving cell. It affects the probability of triggering handovers from the serving cell to its NO intra-frequency neighboring cells. A smaller value of this parameter leads to a higher probability. For details, see 3GPP TS 36.331.

NO

No

None

Indicates the specific frequency offset of the serving cell. This parameter is contained in the intra-frequency measurement control information NO and is related to the handover difficulty between the serving cell and the neighboring cell. For details, see 3GPP TS 36.331.

NO

No

None

Indicates the first logical root sequence, which is used to generate the preamble sequence. Each logical root sequence corresponds to a NO physical root sequence. For the mapping between logical root sequences and physical root sequences, see 3GPP TS 36.211.

YES

No

LBFD-002010 / TDLBFD-002010

Indicates the speed flag of the cell. Set this parameter to ULTRA_HIGH_SPE ED if the cell is used to provide coverage for an ultra-high-speed NO railway. Set this parameter to HIGH_SPEED if the cell is used to provide coverage for a high way. Set this parameter to LOW_SPEED in other scenarios.

NO

No

LOFD-001007 / TDLOFD-001007 LOFD-001008 / TDLOFD-001008

Indicates the preamble format used in the cell. Cells set up on one LBBP must use the NO same preamble format. For details, see 3GPP TS 36.211.

NO

No

LBFD-002010 / TDLBFD-002010

Indicates the radius NO of the cell.

NO

No

LBFD-002010 / TDLBFD-002010

Indicates whether to configure bandwidth customization for the cell. Bandwidth customization is NO available only when the bandwidth is 5 MHz, 10 MHz, 15 MHz, or 20 MHz. Indicates the customized UL cell bandwidth. Bandwidth customization is NO available only when the bandwidth is 5 MHz, 10 MHz, 15 MHz, or 20 MHz.

NO

No

LOFD-001051

NO

No

LOFD-001051

Indicates the customized DL cell bandwidth. Bandwidth customization is NO available only when the bandwidth is 5 MHz, 10 MHz, 15 MHz, or 20 MHz.

NO

No

LOFD-001051

Indicates whether to set an emergency NO area ID.

NO

No

LBFD-002009 / TDLBFD-002009

Indicates the emergency area ID. NO For details, see 3GPP TS 36.413.

NO

No

LBFD-002009 / TDLBFD-002009

Indicates whether to set the maximum transmit power that NO a UE can apply to uplink transmission in the cell.

NO

No

LBFD-001001 LBFD-002009 LBFD-002026

Indicates the maximum transmit power that a UE can apply to uplink transmission in the cell. It is contained in system information block type 1 (SIB1). If this NO parameter is not specified in SIB1, the maximum transmit power that the UE can physically achieve is used as this maximum transmit power. Indicates whether to enable or disable NO the multi-RRU cell feature.

NO

No

LBFD-001001 LBFD-002009 LBFD-002026

NO

No

TDLOFD-001075

Indicates the type of NO the multi-RRU cell.

NO

No

TDLOFD-001075

Indicates the CPRI compression type of NO the cell.

NO

No

None

Indicates the state NO of the cell instance.

NO

Yes

None

Indicates the reason that causes the latest state change of the cell, which NO can be a cell activation success or a cell setup failure.

NO

Yes

None

Indicates the latest setup time of the cell.

NO

NO

Yes

None

Indicates the latest setup type of the cell.

NO

NO

Yes

None

Indicates the latest remove time of the cell.

NO

NO

Yes

None

Indicates the latest remove type of the cell.

NO

NO

Yes

None

Indicates the energy saving status of the cell. There are four states: RF intelligent shutdown, cell NO intelligent shutdown, low power consumption mode, and automatic power-off at a specified time.

NO

Yes

None

Indicates the slot number of the baseband processing board where the cell is configured.

NO

NO

Yes

None

Indicates the NO topology of the cell.

NO

Yes

None

Indicates the cabinet number of NO the RRU or RFU that serves the cell. Indicates the subrack number of NO the RRU or RFU that serves the cell. Indicates the slot number of the RRU NO or RFU that serves the cell. Indicates whether the cell is in the symbol power saving state.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the maximum transmit power of the cell. The value 65535 indicates that this parameter is invalid, NO which can be changed by modifying the PDSCH configuration.

NO

Yes

None

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB. Indicates the maximum number of layers, that is, the NO rank of beamforming.

YES

No

None

NO

No

TDLOFD-001049 TDLOFD-009003

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the interval between periodic measurement reports that are sent NO after a DL ICIC measurement event is triggered. For details, see 3GPP TS 36.331.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the maximum number of cells to be included in each measurement report NO after a DL ICIC measurement event is triggered. For details, see 3GPP TS 36.331.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the number of periodic measurement reports after a DL NO ICIC measurement event is triggered. For details, see 3GPP TS 36.331.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the quantity to be included in the measurement report after a DL ICIC measurement event is triggered. The quantity can be RSRP or RSRQ. The measured RSRP values are stable, varying little with the load, and therefore there is little signal fluctuation. The NO measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. If this parameter is set to BOTH, the actual quantity to be used is the same as the DL ICIC measurement trigger quantity. For details, see 3GPP TS 36.331. Indicates the quantity used in the evaluation of a DL ICIC measurement event. The quantity can be RSRP or RSRQ. The measured RSRP values are stable, varying little with the NO load, and therefore there is little signal fluctuation. The measured RSRQ values vary with the load but are likely to reflect the signal quality of the cell in real time.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the hysteresis for the DL ICIC measurement event. This parameter is used to decrease NO frequent triggering of event evaluations due to radio signal fluctuations. For details, see 3GPP TS 36.331. Indicates the time-totrigger for the DL ICIC measurement event. When detecting that the signal quality in the serving cell and that in at least one neighboring cell meet the entering condition, the UE NO does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously meets the entering condition during the time-to-trigger.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the offset for the DL ICIC measurement event. If this parameter is set to a large value, the signal quality of the neighboring cell NO must be significantly better than that of the serving cell before a DL ICIC measurement event can be triggered. For details, see 3GPP TS 36.331.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the switch for the functionality of the low power consumption mode. The cell can enter the low power NO consumption mode only when this parameter is set to ON and specific conditions are met.

YES

No

LOFD-001040 / TDLOFD-001040

NO

No

LOFD-001040

Indicates the switch for forcibly entering the low power consumption mode. When both this switch and the functionality switch are set to ON, the cell enters the low power consumption mode as soon as the wait time for entering the mode elapses, regardless of whether it is within the low power consumption period. NO When the functionality switch is set to ON but this switch is set to OFF, the cell enters the low power consumption mode as soon as the wait time for entering the mode elapses, if a Mains Input Abnormal alarm indicating an absence of AC power supplies is reported within the low power Indicates the start time of the low NO power consumption mode. Indicates the stop time of the low power consumption mode. If the stop time is earlier than NO or the same as the start time, the stop time is assumed to be a time of the next day. Indicates the duration in which the transmit power for services is NO reduced in the cell in low power consumption mode.

NO

No

LOFD-001040

NO

No

LOFD-001040

NO

No

LOFD-001040 / TDLOFD-001040

NO

No

LOFD-001040 / TDLOFD-001040

Indicates the duration in which the reference signal transmit power is NO reduced in the cell in low power consumption mode. Indicates the duration in which RF channels are NO shut down in the cell in low power consumption mode. Indicates the percentage of the transmit power for services to the total transmit power for services when the NO low power consumption mode is implemented by means of reducing the transmit power for services. Indicates the amount by which the reference signal transmit power is NO reduced in the cell in low power consumption mode.

NO

No

LOFD-001040 / TDLOFD-001040

NO

No

LOFD-001040 / TDLOFD-001040

NO

No

LOFD-001040 / TDLOFD-001040

NO

No

LOFD-001040 / TDLOFD-001040

Indicates the duration when the cell stays in normal mode before entering the low power consumption mode. In low power consumption mode, a cell automatically takes the following actions in sequence: (1) reduces the transmit power for services; (2) reduces the transmit power for NO reference signals; (3) shuts down power amplifiers (PAs) for half of the TX channels in the cell; (4) shuts down the cell. This duration smoothes the transition from the normal mode to the low power consumption mode for the cell. If the conditions for the cell to enter the low power consumption mode are no longer Indicates the local ID of the cell. It uniquely identifies a YES cell within an eNodeB.

NO

No

LOFD-001040 / TDLOFD-001040

YES

No

None

Indicates whether to set the upper and lower limits of the CIO adjustment range for the cell. If this parameter is set to CFG, the CIO for the cell can be changed by an amount within the range specified by the upper and lower limits. If this parameter is set to NOT_CFG, the upper and lower limits of the CIO NO adjustment range for the cell in intrafrequency MRO are calculated by using the following formulas: Lower limit = Off + ofs + ocs - ofn + Hys - 5, Upper limit = Off + ofs + ocs - ofn + Hys -1, where Off is the offset for intrafrequency handover, ofs and ofn are the frequency-specific offsets for the

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the upper limit of the CIO NO adjustment range for the cell.

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the lower limit of the CIO adjustment range for the cell.

NO

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the local cell ID. It uniquely identifies a cell within a BS.

YES

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the Allocation and Retention Priority (ARP) threshold for the Golden-level services. A service is defined as a Golden-level NO service if its ARP value is smaller than this threshold. The service priority has a negative correlation with the ARP value.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the Allocation and Retention Priority (ARP) threshold for the Silver-level services. A service is defined as a Silver-level service if its ARP value is smaller than or equal to the value of this parameter and is larger than the NO value of GoldServiceArpThd . A service is defined as a Bronzelevel service if its ARP value is larger than the value of this parameter. The service priority has a negative correlation with the ARP value. Indicates the admission threshold for the handed-over service with QCI of 1. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 1 is above or equal to this threshold, the NO handed-over service with QCI of 1 can be admitted. If the satisfaction rate of services with QCI of 1 is below this threshold, the handed-over service with QCI of 1 cannot be admitted.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the admission threshold for the handed-over service with QCI of 2. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 2 is above or equal to this threshold, the NO handed-over service with QCI of 2 can be admitted. If the satisfaction rate of services with QCI of 2 is below this threshold, the handed-over service with QCI of 2 cannot be admitted. Indicates the admission threshold for the handed-over service with QCI of 3. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 3 is above or equal to this threshold, the NO handed-over service with QCI of 3 can be admitted. If the satisfaction rate of services with QCI of 3 is below this threshold, the handed-over service with QCI of 3 cannot be admitted.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the admission threshold for the handed-over service with QCI of 4. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 4 is above or equal to this threshold, the NO handed-over service with QCI of 4 can be admitted. If the satisfaction rate of services with QCI of 4 is below this threshold, the handed-over service with QCI of 4 cannot be admitted.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the offset for admission of new Gold-level services. The value of this parameter applies in both UL and DL. New Goldlevel services and handed-over services with QCI N can be admitted if both the following conditions are met: (1) The satisfaction rate of services with QCI N is higher than or equal to the NO sum of this offset and the admission threshold for the handed-over services with QCI N; (2) The satisfaction rate of services with any other QCI is higher than the corresponding admission threshold for the handed-over services with that QCI. If the satisfaction rate of services with any

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the offset for admission of new Silver-level services. The value of this parameter applies in both UL and DL. New Silverlevel services and handed-over services with QCI N can be admitted if both the following conditions are met: (1) The satisfaction rate of services with QCI N is higher than or equal to the NO sum of this offset and the admission threshold for the handed-over services with QCI N; (2) The satisfaction rate of services with any other QCI is higher than the corresponding admission threshold for the handed-over services with that QCI. If the satisfaction rate of services with any

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the offset for admission of new Bronze-level services. The value of this parameter applies in both UL and DL. New Bronze-level services and handed-over services with QCI N can be admitted if both the following conditions are met: (1) The satisfaction rate of services with QCI N is higher NO than or equal to the sum of this offset and the admission threshold for the handed-over services with QCI N; (2) The satisfaction rate of services with any other QCI is higher than the corresponding admission threshold for the handed-over services with that QCI. If the satisfaction rate of

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the congestion threshold for services with QCI of 1. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 1 in the cell becomes lower than this threshold, the services with QCI of NO 1 enter the congested state. If the satisfaction rate of services with QCI of 1 in the cell becomes higher than the sum of this threshold and the congestion relief offset, the services with QCI of 1 leave the congested state.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the congestion threshold for services with QCI of 2. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 2 in the cell becomes lower than this threshold, the services with QCI of NO 2 enter the congested state. If the satisfaction rate of services with QCI of 2 in the cell becomes higher than the sum of this threshold and the congestion relief offset, the services with QCI of 2 leave the congested state.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the congestion threshold for services with QCI of 3. This threshold applies to both UL and DL. If the satisfaction rate of the services with QCI of 3 in the cell becomes lower than this threshold, the services with NO QCI of 3 enter the congested state. If the satisfaction rate of services with QCI of 3 in the cell becomes higher than the sum of this threshold and the congestion relief offset, the services with QCI of 3 leave the congested state.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the congestion threshold for services with QCI of 4. This threshold applies to both UL and DL. If the satisfaction rate of services with QCI of 4 in the cell becomes lower than this threshold, the services with QCI of NO 4 enter the congested state. If the satisfaction rate of services with QCI of 4 in the cell becomes higher than the sum of this threshold and the congestion relief offset, the services with QCI of 4 leave the congested state.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the rate reduction proportion for Gold-level GBR services. When congestion occurs, the rate that the scheduling algorithm provides for Gold-level GBR services (except VoIP services) is the product of GBR and this proportion.This NO parameter will be removed in the later versions. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the rate reduction proportion for Silver-level GBR services. When congestion occurs, the rate that the scheduling algorithm provides for Silver-level GBR services (except VoIP services) is the product of the GBR and this proportion.This NO parameter will be removed in the later versions. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the rate reduction proportion for Bronze-level GBR services. When congestion occurs, the rate that the scheduling algorithm provides for Bronze-level GBR services (except VoIP services) is the product of GBR and this proportion.This NO parameter will be removed in the later versions. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter. Indicates the threshold for high PRB usage by GBR services. The value of this parameter is expressed in percentage and applies to both UL and DL. If the MAC layer detects that the PRB usage by GBR services NO exceeds the threshold, the usage is high. In this situation, new GBR services are not admitted if GbrUsageSwitch under the RacAlgoSwitch parameter is turned on.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the threshold for low PRB usage by GBR services. The value of this parameter is expressed in percentage and applies to both UL NO and DL. If the MAC layer detects that the PRB usage by GBR services falls below the threshold, the usage is considered to be low.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the Allocation and Retention Priority (ARP) threshold for low Energy Efficiency Ratio (EER) services. If the ARP value of a service is less than the value of this parameter, the service will not be released for congestion NO control.This parameter will be removed in the later versions. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

Indicates the congestion release offset. The service of a specific QCI exits the congestion state if the satisfaction rate of the service exceeds the sum of this congestion release offset and the congestion NO threshold for the QCI. The service retains the congestion state if the satisfaction rate is below the sum of this congestion release offset and the congestion threshold for the QCI. Indicates the Allocation and Retention Priority (ARP) threshold for preemption. The services that have ARP values larger than or equal to the value of this parameter are preemptible.This parameter will be NO removed in the later versions. In this version, the setting of this parameter is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002024 / TDLBFD-002024

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-00102901 / TDLOFD-00102901

Indicates the threshold for deciding on whether the UL RB usage is high. This threshold applies to UL admission decision. NO If the UL RB usage reported by the MAC layer is above this threshold, the UL RB usage is assumed to be high.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the threshold for deciding on whether the DL resource block (RB) usage is high. This threshold applies to DL admission decision. NO If the usage of the DL RB reported by the MAC layer is above this threshold, the DL RB usage is assumed to be high.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the threshold for deciding on whether the UL RB usage is low. It applies to UL admission decision. NO If the UL RB usage reported by the MAC layer is below this threshold, the UL RB usage is assumed to be low.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the threshold for deciding on whether the DL resource block (RB) usage is low. This threshold applies to DL admission decision. NO If the usage of the DL RB reported by the MAC layer is below this threshold, the usage of the DL RB is assumed to be low.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the maximum number of non-GBR services (excluding IP Multimedia Subsystem [IMS] NO services) that can be provided by a cell. The value of this parameter is applied to both UL and DL.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates whether to enable or disable RF channel intelligent shutdown for the cell. RF channel intelligent NO shutdown can be performed in the cell only when this parameter is set to ON and certain conditions are met.

YES

No

LOFD-001039 / TDLOFD-001039

NO

No

LOFD-001039 / TDLOFD-001039

Indicates the start time of the cell RF intelligent shutdown.

NO

NO

No

LOFD-001039

Indicates the stop time of RF channel intelligent shutdown for the cell. If the stop time is earlier NO than or the same as the start time, the stop time is assumed to be a time of the next day. Indicates the value by which the reference signal power is increased during the RF channel intelligent shutdown period. The reference signal power NO increases by the value specified by this parameter to ensure coverage of the cell. If this parameter is set to a value greater than 3, the value 3 applies in effect. Indicates the local identity of the cell. It uniquely identifies a YES cell within an eNodeB.

NO

No

LOFD-001039 / TDLOFD-001039

NO

No

LOFD-001039 / TDLOFD-001039

YES

No

None

Indicates the switch for the remote interference cancellation algorithm. If this switch is turned on, the eNodeB performs remote interference detection and NO records in call history record (CHR) logs if any interference is detected. If this switch is turned off, the eNodeB does not perform remote interference detection. Indicates the number of empty symbols in an uplink pilot timeslot (UpPTS). If this parameter is set to a non-zero value N, then no data is transmitted within the N symbols starting from the NO first symbol in the UpPTS. Note that, for any given special subframe configuration, the value of this parameter cannot be greater than the total number of symbols contained in the UpPTS. Indicates whether to empty the last NO symbol in each uplink subframe. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

None

NO

No

None

NO

No

None

YES

No

LOFD-001042 / TDLOFD-001042

Indicates whether to enable or disable cell intelligent shutdown. Cell intelligent shutdown can be performed only when this parameter is set to ON and specific conditions are met. For cell intelligent NO shutdown, each intra-eNodeB interfrequency neighboring cell (also called basic cell) must have its cell intelligent shutdown enabled and the UL or DL PRB usage threshold set to 0. Indicates the start time of cell intelligent shutdown. If the stop time is earlier NO than or the same as the start time, the stop time is assumed to be a time of the next day. Indicates the stop time of cell intelligent shutdown. If the stop time is earlier NO than or the same as the start time, the stop time is assumed to be a time of the next day.

NO

No

LOFD-001042 / TDLOFD-001042

NO

No

LOFD-001042 / TDLOFD-001042

NO

No

LOFD-001042 / TDLOFD-001042

Indicates the DL PRB usage threshold for cell intelligent shutdown. For cell intelligent shutdown, each intra-eNodeB interfrequency neighboring cell (also called basic cell) must have its cell intelligent shutdown enabled and the UL or DL PRB usage threshold set to 0. NO The local cell enters cell intelligent shutdown mode if its UL and DL loads are lower than the UL and DL PRB usage thresholds, respectively, and the total load of the local and basic cells is lower than the sum of the UL PRB usage threshold and offset as well as the sum of the DL PRB usage threshold and

NO

No

LOFD-001042 / TDLOFD-001042

Indicates the DL PRB usage offset for cell intelligent shutdown. For cell intelligent shutdown, each intra-eNodeB interfrequency neighboring cell (also called basic cell) must have its cell intelligent shutdown enabled and the UL or DL PRB usage threshold set to 0. The local cell enters NO cell intelligent shutdown mode if its UL and DL loads are lower than the UL and DL PRB usage thresholds, respectively, and the total load of the local and basic cells is lower than the sum of the UL PRB usage threshold and offset as well as the sum of the DL PRB usage threshold and offset. The local cell

NO

No

LOFD-001042 / TDLOFD-001042

Indicates the UL PRB usage threshold for cell intelligent shutdown. For cell intelligent shutdown, each intra-eNodeB interfrequency neighboring cell (also called basic cell) must have its cell intelligent shutdown enabled and the UL or DL PRB usage threshold set to 0. NO The local cell enters cell intelligent shutdown mode if its UL and DL loads are lower than the UL and DL PRB usage thresholds, respectively, and the total load of the local and basic cells is lower than the sum of the UL PRB usage threshold and offset as well as the sum of the DL PRB usage threshold and

NO

No

LOFD-001042 / TDLOFD-001042

Indicates the UL PRB usage offset for cell intelligent shutdown. For cell intelligent shutdown, each intra-eNodeB interfrequency neighboring cell (also called basic cell) must have its cell intelligent shutdown enabled and the UL or DL PRB usage threshold set to 0. The local cell enters NO cell intelligent shutdown mode if its UL and DL loads are lower than the UL and DL PRB usage thresholds, respectively, and the total load of the local and basic cells is lower than the sum of the UL PRB usage threshold and offset as well as the sum of the DL PRB usage threshold and offset. The local cell Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LOFD-001042 / TDLOFD-001042

YES

No

None

Indicates the interval between periodic measurement reports that are sent after a UL ICIC measurement event is triggered. For details, see 3GPP TS 36.331. In this version, this NO parameter still supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from later versions. Indicates the maximum number of cells to be included in each measurement report after a UL ICIC measurement event is triggered. For details, see 3GPP TS 36.331. In this version, this NO parameter still supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the number of periodic measurement reports after a UL ICIC measurement event is triggered. For details, see 3GPP TS 36.331. In this version, this parameter still NO supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the quantity to be included in the measurement report for a UL ICIC measurement event. The quantity can be RSRP or RSRQ. The measured RSRP values are stable, varying little with the load, and therefore there is little signal fluctuation. The measured RSRQ values vary with the NO load and are likely to reflect the signal quality of the cell in real time. If this parameter is set to BOTH, the actual quantity to be used is the same as the triggering quantity for the UL ICIC measurement event. For details, see 3GPP TS 36.331. In this version, this parameter still supports setting

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the quantity used in the evaluation of a UL ICIC measurement event. The quantity can be RSRP or RSRQ. The measured RSRP values are stable, varying little with the load, and therefore there is little signal fluctuation. The measured RSRQ values vary with the load and are likely NO to reflect the signal quality of the cell in real time. In this version, this parameter still supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the hysteresis for the UL ICIC measurement event. This parameter is used to decrease frequent triggering of event evaluations due to radio signal fluctuations. For details, see 3GPP TS 36.331. NO In this version, this parameter still supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the time-totrigger for the UL ICIC measurement event. When detecting that the signal quality in the serving cell and that in at least one neighboring cell meet the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only NO when the signal quality continuously meets the entering condition during the time-to-trigger. In this version, this parameter still supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from later versions.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the offset for the UL ICIC measurement event. If this parameter is set to a large value, the signal quality of the neighboring cell NO must be significantly better than that of the serving cell before a UL ICIC measurement event is triggered. For details, see 3GPP TS 36.331.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the UL scheduling policy, which determines the scheduling priority order in which UEs are arranged in UL. There are four UL scheduling strategies: MAX C/I, proportional fair (PF), round Robin (RR), and enhanced proportional fair (EPF). The MAX C/I policy schedules UEs in descending NO order of average signal to interference plus noise ratio (SINR). The PF policy schedules UEs in ascending order of ratio of the data rate to the SINR. The RR policy schedules each UE in sequence, and therefore each UE has an equal opportunity to be scheduled. The EPF policy

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the switch that is used to control whether to enable or disable UL adaptive HARQ. If this switch is set to ADAPTIVE_HARQ_ SW_OFF, UL data is retransmitted by non-adaptive synchronous HARQ. If this switch is set to ADAPTIVE_HARQ_ SW_ON, UL data is retransmitted by NO adaptive synchronous HARQ. If this switch is set to ADAPTIVE_HARQ_ SW_SEMION, adaptive HARQ is triggered when a UL grant is delivered to an HARQ process that is previously suspended due to reasons such as resource collision, activation of a measurement gap, and PDCCH Indicates the target IBLER of the SINR adjustment algorithm. A greater parameter value NO indicates a greater SINR adjustment value, and thus a higher-level MCS is used. Indicates the ratio of the maximum bandwidth resources that the uplink scheduler NO can allocate to preallocation users to the total system bandwidth.

NO

No

LBFD-002006 / TDLBFD-002006

NO

No

LBFD-001006 / TDLBFD-001006

NO

No

LOFD-00101502 / TDLOFD-00101502

Indicates the minimum interval between two preallocations. That is, the actual interval between two preNO allocations of one UE must be longer than or equal to the value of this parameter. Indicates the data amount preallocated to each user.

NO

No

LOFD-00101502 / TDLOFD-00101502

NO

NO

No

LOFD-00101502 / TDLOFD-00101502

Indicates whether frequency hopping (FH) is enabled or NO disabled and which FH type is used.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the percentage of free shared RBs on the PUSCH in scheduling based on free users and subscribers. The other RBs on the PUSCH are allocated to subscribers. When sufficient capacity is available, the percentage of RBs occupied by free NO users and that occupied by subscribers will reach the preset values. Changes in this parameter affect the percentage of RBs for free users and that for subscribers. The value of this parameter cannot be changed when the cell is active.

NO

No

LOFD-00101502 / TDLOFD-00101502 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the data length that the UL scheduler assigns to UEs that have sent scheduling requests. Within the NO data length, the UEs reports their buffer status and transmit certain data.

NO

No

LOFD-00101502 / TDLOFD-00101502

Indicates the threshold for the number of consecutive zeropayload packets received by the eNodeB. After receiving consecutive zeroNO payload packets of a number that is equal to the value of this parameter, the eNodeB performs implicit release of semi-persistent resources. Indicates the local identity of the cell. It uniquely identifies a YES cell within an eNodeB.

NO

No

LOFD-00101502 / TDLOFD-00101502

YES

No

LOFD-001074

Indicates the switch used to enable or disable inter-RAT cell shutdown. If this switch is turned on, regardless of the inter-RAT cell load, UEs in a lightly loaded E-UTRAN cell are handed over or redirected to neighboring GERAN or UTRAN NO cells. Then, the EUTRAN cell does not serve any UEs. In this situation, the carrier of this cell can be shut down to save energy. Currently, inter-RAT cell shutdown applies only to overlapping areas of the E-UTRAN and the UTRAN.

NO

No

LOFD-001074

Indicates the start time of inter-RAT cell shutdown. If the stop time is earlier than or the same as the start time, the stop time is assumed to be the time of the next day. If the switch for inter- NO RAT cell shutdown is turned on, interRAT cell shutdown can be performed during the period specified by the start time and stop time of inter-RAT cell shutdown.

NO

No

LOFD-001074

Indicates the stop time of inter-RAT cell shutdown. If the stop time is earlier than or the same as the start time, the stop time is assumed to be the time of the next day. If the switch for inter- NO RAT cell shutdown is turned on, interRAT cell shutdown can be performed during the period specified by the start time and stop time of inter-RAT cell shutdown.

NO

No

LOFD-001074

Indicates the threshold number of UEs served by the cell. Inter-RAT cell shutdown is performed if shutdown conditions are met and the number of UEs served by the cell is less than or equal to this threshold. The shutdown conditions include the inter-RAT cell NO shutdown switch, specified duration, and UL/DL physical resource block (PRB) thresholds. In this situation, the eNodeB automatically hands over or redirects the UEs in the EUTRAN cell to GERAN or UTRAN cells, and then shuts down the carrier of the EUTRAN cell.

NO

No

LOFD-001074

Indicates the threshold number of DL physical resource blocks (PRBs) in the cell. Inter-RAT cell shutdown is performed if shutdown conditions are met and the number of UL PRBs and DL PRBs in the cell are less than or equal to the corresponding PRB thresholds. The shutdown NO conditions include the setting of the inter-RAT cell shutdown switch, specified duration, and threshold of the number of UEs served by the cell. In this situation, the eNodeB automatically hands over or redirects the UEs in the EUTRAN cell to GERAN or UTRAN cells, and then shuts down the

NO

No

LOFD-001074

Indicates the threshold number of UL physical resource blocks (PRBs) in the cell. Inter-RAT cell shutdown is performed if shutdown conditions are met and the number of UL PRBs and DL PRBs in the cell are less than or equal to the corresponding PRB thresholds. The shutdown NO conditions include the setting of the inter-RAT cell shutdown switch, specified duration, and threshold of the number of UEs served by the cell. In this situation, the eNodeB automatically hands over or redirects the UEs in the EUTRAN cell to GERAN or UTRAN cells, and then shuts down the Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LOFD-001074

YES

No

None

RachAdjSwitch: Indicates the switch used to enable or disable random access channel (RACH) resource adjustment, which adaptively adjusts the RACH resources in the cell based on the access type and the number of accesses. If the switch is turned off, RACH resource adjustment is NO disabled. HoRaSwitch: Indicates the switch used to control the random access mode applied during handovers. If the switch is turned on, the eNodeB instructs UEs to use the noncontention-based random access mode during handovers. If the switch is turned off, the

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002010 / TDLBFD-002010

Indicates the switch used to enable or disable change in the cell-specific SRS subframe configuration (that is, the adjustment on the setting of the SrsSubframeCfg parameter). If the switch is turned on, the algorithm NO dynamically adjusts the SRS subframe configuration based on the usage of cell resources. If the switch is turned off, the algorithm uses the initial configuration and does not perform dynamic switching.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the switch used to enable or disable the PUCCH resource adjustment algorithm. If the switch is turned on, PUCCH resource adjustment is NO initiated when the PUCCH resources are insufficient or excessive. If the switch is turned off, PUCCH resource adjustment is disabled.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the switch that is used to enable and disable the Active Queue Management (AQM) algorithm. If this switch is set to ON, the AQM function is enabled to prevent or control congestion. The length of the PDCP NO packet queue is maintained at a relatively small value to help achieve an appropriate tradeoff between throughput and time latency. If this switch is set to OFF, the AQM function is disabled.

NO

No

LOFD-001027 / TDLOFD-001027

CqiAdjAlgoSwitch: Indicates the switch used to control whether to allow the eNodeB to adjust the UE-reported CQI on the basis of Initial Block Error Rate (IBLER). If this switch is turned on, the CQI adjustment algorithm is enabled. In the case, the eNodeB would adjust the UEreported CQI based NO on the IBLER. If this switch is turned off, the CQI adjustment algorithm is disabled. In this case, the eNodeB would not adjust the UE-reported CQI based on the IBLER. StepVarySwitch: Indicates the switch used to enable or disable the variablestep-based adjustment Indicates the switch used to enable or disable radio link NO failure (RLF) detection for UL links. Indicates the switch used to enable or NO disable dynamic voltage adjustment.

NO

No

LOFD-001002 / TDLOFD-001002 LOFD-00101501 / TDLOFD-00101501 LOFD-00101502 / TDLOFD-00101502

NO

No

None

NO

No

LOFD-001025

Indicates the switches used to enable or disable the admission and load control algorithms. DlSwitch: Indicates whether to enable or disable the satisfaction ratebased admission control algorithm in the downlink. If this switch is turned on, the algorithm is enabled. If this switch is turned off, NO the algorithm is disabled.The satisfaction rate of services with the QCI of 1 is calculated by using the same method as that for VoIP services. However, this method cannot be used to calculate the satisfaction rate of non-VoIP services. Therefore, if services with the QCI of 1 are all VoIP services, it is

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024 LOFD-00102901 / TDLOFD-00102901

Indicates the switches used to enable or disable load balancing algorithms. There are six load balancing switches, which are used to control the intrafrequency, intrafrequency idle, interfrequency, UTRAN, GERAN, and CDMA2000 load balancing algorithms, respectively. If one NO switch is set to ON, the corresponding algorithm is enabled to balance the loads between neighboring cells of the specified category. If IntraFreqMlbSwitch is set to ON, the intra-frequency load balancing is enabled and therefore IntraFreqIdleMlbSwi tch becomes valid.

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the switches used to enable or disable power control for PDSCH, PDCCH, and PHICH. PdschSpsPcSwitch: Indicates the switch for power control during semipersistent scheduling on the PDSCH. If the switch is turned off, power is allocated evenly during semipersistent NO scheduling on the PDSCH. If the switch is turned on, power control is applied during semipersistent scheduling on the PDSCH, ensuring communication quality (indicated by IBLER) of VoIP services in the QPSK modulation scheme. PhichInnerLoopPcS witch: Indicates the switch for PHICH

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016

Indicates the switches used to enable or disable power control for PUSCH and PUCCH. CloseLoopSpsSwitc h: If this switch is turned off, closedloop power control is not performed for PUSCH in semipersistent scheduling mode. If this switch is turned on, TPC commands are adjusted based NO on correctness of the initially received data packet to decrease the IBLER. InnerLoopPuschSwi tch: If this switch is turned off, innerloop power control is not performed for PUSCH in dynamic scheduling mode. If this switch is turned on, inner-loop power control is performed for PUSCH in dynamic BfSwitch: Indicates whether to enable or disable the beamforming algorithm. If the switch is turned on, UEs in the cell can be served by the beamforming algorithm. If the NO switch is turned off, UEs in the cell cannot be served by the beamforming algorithm. The beamforming algorithm is disabled by default. It must be enabled manually if required.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-002026 / TDLBFD-002026

NO

No

TDLOFD-001049 TDLOFD-001061 TDLOFD-009003

Indicates the switches related to DL scheduling in the cell. FreqSelSwitch: Indicates whether to enable or disable frequency selection and scheduling. If this switch is turned on, data is transmitted on the frequency band with good-quality channels. ServiceDiffSwitch: Indicates whether to NO enable or disable service differentiation. If this switch is turned on, service differentiation is available. If this switch is turned off, service differentiation is unavailable. SpsSchSwitch: Indicates whether to enable or disable semi-persistent scheduling during talk spurts of VoIP

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the switches related to uplink (UL) scheduling in the cell. The switches are used to enable or disable specific UL scheduling functions. SpsSchSwitch: Indicates whether to enable or disable semi-persistent scheduling during talk spurts of VoIP services. If this switch is turned on, NO semi-persistent scheduling is applied. If this switch is turned off, dynamic scheduling is applied. SinrAdjustSwitch: Indicates whether to adjust the measured SINR based on ACK/NACK messages in a UL HARQ process. PreAllocationSwitch : Indicates whether to enable or disable Indicates whether to enable or disable eRAN sharing for admission and scheduling. If this switch is turned on, NO operators share data channel resources according to the specified percentages.

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015 LOFD-001048 / TDLOFD-001048 LOFD-001016 / TDLOFD-001016 LOFD-001067

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002023 / TDLBFD-002023 LBFD-002025 / TDLBFD-002025

Indicates the switch related to the frequency-prioritybased interfrequency handover. FreqPriorIFHOSwitc h: Indicates the frequency-prioritybased interfrequency handover switch.Frequencypriority-based interfrequency handover is applicable when the eNodeB provides dual NO coverage and one frequency is preferred for carrying services. If this switch is set to On, the frequencypriority-based interfrequency handover will be triggered even when the serving cell provides a good signal quality. If this switch is set to Off, the frequencypriority-based interfrequency handover Indicates the switch used to enable or disable the multiuser beamforming algorithm. If this switch and the switch for the beamforming algorithm are both NO turned on, the multiuser beamforming algorithm is enabled. If this switch is turned off, the multiuser beamforming algorithm is disabled.

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the switch used to enable or disable distancebased handovers. If this switch is turned on, distance-based NO handovers are allowed. If this switch is turned off, distance-based handovers are prohibited. Indicates the switch for the access barring algorithm. If this parameter is set to ACBAR_SWITCH_ DYNAMIC, dynamic access barring is enabled. In this situation, the access probability factor and the average access barring duration for mobile-originated calls are dynamically NO adjusted based on the current cell load. If this parameter is set to ACBAR_SWITCH_ STATIC, static access barring is also enabled. In this situation, the access probability factor and the average access barring duration for mobile-originated calls are configured in the access barring information. Indicates the switch used to enable or NO disable the UL CoMP algorithm.

NO

No

LBFD-00201804 / TDLBFD-00201804 LOFD-001072 / TDLOFD-001072 LOFD-001073 / TDLOFD-001073

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002009 / TDLBFD-002009

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the switch used to enable or disable MRC/IRC adaptation. MRC is short for maximum NO ratio combining, and IRC is short for interference rejection combining. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

None

YES

No

None

Indicates the band division scheme used in downlink ICIC. The band division in the cell is adjusted according NO to the setting of this parameter so that the edge bands for neighboring cells do not overlap.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the offset of the DCI power relative to the reference signal NO power when the PDCCH channel carries dedicated control information. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-002016 / TDLBFD-002016

NO

No

LBFD-002016 / TDLBFD-002016

YES

No

LBFD-002016 / TDLBFD-002016

Indicates the PA value of cell center UEs when DL ICIC is enabled.

NO

NO

No

LBFD-002016 / TDLBFD-002016

Indicates the PA value of cell edge UEs when DL ICIC is enabled.

NO

NO

No

LBFD-002016 / TDLBFD-002016

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the power offset between the PHICH TX power and the RS power. NO This offset is used when PHICH power control is disabled. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-002016 / TDLBFD-002016

NO

No

LBFD-002016 / TDLBFD-002016

YES

No

None

Indicates the switch of the DL scheduling policy. According to the Max C/I scheduling policy, the UE with good-quality channels are scheduled and hence the spectral efficiency is very high. The QoS and fairness among users, however, cannot be ensured. The Max C/I scheduling policy NO can be used to verify the maximum capacity of the system. The RR scheduling policy is the fairest scheduling policy. When RR is adopted, the system capacity is the smallest. Therefore, RR is used only to verify the upper bound of the scheduling fairness in the system. In terms of the

NO

No

LBFD-002025 / TDLBFD-002025 LOFD-001015 / TDLOFD-001015

Indicates the percentage of free shared RBs on the PDSCH in scheduling based on pay-free users and pay users. The other RBs on the PDSCH are allocated to pay users. When sufficient capacity is available, the percentage of RBs occupied by payNO free users and that occupied by pay users will reach the preset values. Changes in this parameter affect the percentage of RBs for pay-free users and that for pay users. Modifying the value of this parameter for an active cell will lead to the re-setup of the cell.

NO

No

LOFD-00101502 / TDLOFD-00101502 LBFD-002023 / TDLBFD-002023 LBFD-002024 / TDLBFD-002024

Indicates the weight of the point-to-point (P2P) service, which is used in enhanced proportional fair (EPF) scheduling. The value of this parameter is used in calculating the priority of a UE during scheduling and therefore determines the amount of physical NO resources to be allocated to the UE that requests the P2P service. The P2P service priority has a positive correlation with the value of this parameter. This parameter is valid only when the service differentiation function is enabled.

NO

No

LOFD-001064/ TDLOFD-001064

Indicates the weight of the non-P2P service used in enhanced proportional fair (EPF) scheduling. The value of this parameter is used in calculating the priority of a UE during scheduling and therefore determines the amount of physical resources to be NO allocated to the UE that requests the non-P2P service. The priority of the non-P2P service has a positive correlation with the value of this parameter. This parameter is valid only when the service differentiation function is enabled.

NO

No

LOFD-001064/ TDLOFD-001064

Indicates the maximum number of layers (the rank) in the implementation of multiple-input multiple-output (MIMO) in DL scheduling.

NO

NO

No

LOFD-00101502 LBFD-002023 LBFD-002024

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the threshold for triggering intrafrequency load balancing. Intrafrequency load balancing is started if the cell load exceeds the sum of the threshold and the offset, and is stopped if the cell NO load falls below the threshold.The sum of this threshold and the load offset must be greater than the sum of the UL/DL PRB usage threshold and UL/DL PRB offset for cell intelligent shutdown. Indicates the threshold for triggering interfrequency load balancing. Load balancing between the cell and its interfrequency neighboring cell is triggered if the cell load exceeds the sum of this threshold and the NO offset, and is stopped if the cell load falls below this threshold.The sum of this threshold and the load offset must be greater than the sum of the UL/DL PRB usage threshold and UL/DL PRB offset for cell intelligent shutdown.

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001032 / TDLOFD-001032

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001032 / TDLOFD-001032

Indicates the threshold for triggering inter-RAT load balancing. Load balancing between the cell and its inter-RAT neighboring cell is triggered if the cell load exceeds the sum of this threshold and the offset, and is NO stopped if the cell load falls below this threshold.The sum of this threshold and the load offset must be greater than the sum of the UL/DL PRB usage threshold and UL/DL PRB offset for cell intelligent shutdown.

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the period of the inter-cell load exchange. This parameter is contained in the load exchange request message. If the source cell sends a load exchange request message containing a period, the target cell reports its load to the source cell at intervals based on the period. If the source cell sends NO such a message without a period, the target cell reports its load to the source cell at a default interval of 5s. In this version, the parameter still supports setting synchronization between the M2000 and the eNodeB, but is no longer used internally. Avoid using this parameter as it will be removed from Indicates the offset used in the evaluation of whether to trigger load balancing. To prevent load fluctuations from frequently triggering or stopping load balancing, an offset NO needs to be set. That is, a specific load balancing action is taken only if the cell load exceeds the sum of the corresponding load balancing threshold and this offset.

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

Indicates the threshold of load difference between two cells for load balancing. If the load difference between cells exceeds this threshold, the eNodeB determines that load imbalance occurs and therefore initiates NO load balancing between the cells. If the load difference between cells falls below this threshold, the eNodeB determines that load imbalance is resolved and therefore stops load balancing between the cells. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the CCE aggregation level for common signaling. NO

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001032 / TDLOFD-001032 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045

YES

No

None

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the CCE ratio adjustment switch for the PDCCH. If this switch is turned on, the resource allocation algorithm of the PDCCH dynamically adjusts the UL and DL CCE NO ratios within each transmission time interval (TTI) based on CCE usages in UL and DL. If this switch is turned off, the UL and DL CCE ratios are not dynamically adjusted.

NO

No

LBFD-001001 / TDLBFD-001001 TDLOFD-009004

Indicates the number of OFDM symbols initially occupied by the PDCCH. If the switch for dynamic adjustment to the number of OFDM symbols occupied by the PDCCH is turned off, this parameter indicates the number of OFDM symbols that are always occupied by the PDCCH. NO If the switch for dynamic adjustment to the number of OFDM symbols occupied by the PDCCH is turned on, the number of OFDM symbols occupied by the PDCCH is always 4 and 3 for the bandwidths of 1.4 MHz and 3 MHz, respectively, and therefore the parameter setting is invalid. For the Indicates the virtual CCE ratio for the PDCCH. Based on the observed impact of different virtual CCE ratios on NO PDCCH demodulation performance, the intra-frequency LTE networking can be optimized.

NO

No

LBFD-001001 / TDLBFD-001001

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the switch that is used to control whether to enable and disable dynamic adjustment NO on the number of OFDM symbols occupied by PDCCH.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the upper limit for the CCE usage within each TTI. Note that this parameter stops taking effect if the switch for NO dynamically adjusting the number of OFDM symbols on the PDCCH is turned on.

NO

No

LBFD-001001 / TDLBFD-001001 TDLOFD-009005

Indicates the switch used to enable or disable closed-loop adjustment to the PDCCH aggregation level. If this switch is turned on, PDCCH aggregation level is adjusted based on NO the block error rate (BLER) of the PDCCH. If this switch is turned off, PDCCH aggregation level is not adjusted based on the BLER of the PDCCH.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the threshold for the low load state of the SRI resources. The SRI resources enter the low load state if the PUCCH NO resource allocation algorithm detects that the number of admitted UEs is smaller than the value of this parameter.

NO

No

None

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LOFD-002010

Indicates the time when the cell notraffic detection starts. If the stop time is earlier than or the same as the start time, the end time is assumed to be a time of the next day. If the timer for reporting the no-traffic alarm is not set to 0, the eNodeB performs the cell no-traffic detection from the start time to the stop time. Indicates the time when the cell notraffic detection stops. If the stop time is earlier than or the same as the start time, the stop time is assumed to be a time of the next day. If the timer for reporting the no-traffic alarm is not set to 0, the eNodeB performs the cell no-traffic detection from the start time to the stop time.

NO

NO

No

LOFD-002010

NO

NO

No

LOFD-002010

Indicates the length of the timer for the cell no-traffic detection. If there is no traffic in the cell within the duration specified by this parameter, the eNodeB reports the no-access alarm and resets the cell. If this parameter is NO set to 0, the cell notraffic detection is not performed. If the timer for reporting the no-traffic alarm is set to a non-zero value, the eNodeB performs the cell notraffic detection from the start time to the stop time. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LOFD-002010

YES

No

None

Indicates the band division scheme used in uplink ICIC. The band division in the cell is changed according to the NO setting of this parameter so that the edge bands do not overlap between neighboring cells.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the index of a simulated load configuration. The value of this parameter corresponds to SimuLoadCfgIndex in a SimuLoad MO. That is, each index NO corresponds to a specific set of parameters that consistitute one of the multiple simulated load configurations stored in the eNodeB. Indicates the transmission mode adopted by a NO simulated load configuration. Indicates the number of RBs allocated by a simulated load configuration.

NO

No

None

NO

No

None

NO

NO

Yes

None

Indicates the number of RBs for NO commercial services in the cell. Indicates the power allocated by a NO simulated load configuration. Indicates the power for commercial NO services in the cell.

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the number of UEs allocated by a simulated load configuration.

NO

NO

Yes

None

Indicates the number of commercial service UEs, that is, the NO number of UEs that are actually served by the cell. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

Yes

None

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the modification period coefficient for the BCCH. BCCH modification period = Modification period coefficient x Default paging cycle, where the NO BCCH modification period and default paging cycle are measured in unit of radio frames, and the modification period coefficient is specified by this parameter.

NO

No

LBFD-002009

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the offset of the PCFICH transmit power NO relative to the reference signal power.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016

Indicates the offset of the PBCH transmit power NO relative to the reference signal power.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016

Indicates the offset of the transmit power for the cell synchronization NO signals relative to the reference signal power.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016

Indicates the offset of the transmit power for broadcast information on the NO PDSCH channel relative to the reference signal power. Indicates the offset of the transmit power for the paging information NO on the PDSCH channel relative to the reference signal power. Indicates the offset of the transmit power for the random access responses on the NO PDSCH channel relative to the reference signal power. Indicates the offset of the pilot power relative to the NO reference signal power. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016 LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002011 / TDLBFD-002011 LBFD-002016 / TDLBFD-002016 LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002010 / TDLBFD-002010 LBFD-002016 / TDLBFD-002016

NO

No

NO

No

NO

No

None

YES

No

None

Indicates the reference signal power of the cell. For details, see 3GPP TS 36.213.

NO

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016

Indicates the scaling factor index of the Energy Per Resource Element (EPRE) on the PDSCH. This scaling factor is NO determined by the value of this parameter and the antenna port. For details, see 3GPP TS 36.213.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009 LBFD-002016 / TDLBFD-002016

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the step by which the TX power for random access preambles is increased each time after a RACH access failure. If multiple attempts to access the PRACH fail, the UE increases the TX NO power for random access preambles by a step specified by this parameter each time after an access failure to ensure successful access. For details, see 3GPP TS 36.321.

YES

No

LBFD-001001 / TDLBFD-001001

NO

No

LBFD-001001

Indicates the target UE transmit power for the PRACH expected by the eNodeB when PRACH preamble format 0 is applied NO on condition that requirements for preamble detection performance are met. For details, see 3GPP TS 36.321.

NO

No

LBFD-001001

Indicates the threshold for determining the size of Msg3 when a UE selects a preamble from random NO access preamble group A during a random access procedure. For details, see 3GPP TS 36.321.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002002

Indicates the offset to the starting position of each NO PRACH in the frequency domain of the FDD cell.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates whether to configure the PRACH NO configuration index of the FDD cell.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the PRACH NO configuration index of the FDD cell.

NO

No

LBFD-001001 / TDLBFD-001001

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

LBFD-001001 / TDLBFD-001001

Indicates the index of the SRS subframe configuration for the cell. The value SCn, where n is variable, represents configuration n. For example, the value SC0 indicates subframe configuration 0, and the value SC1 indicates subframe configuration 1. If the cell operates in NO FDD mode, the value SC15 is reserved. If the cell operates in TDD mode, the values SC14 and SC15 are reserved. The reserved values cannot be used. For the relationship between the subframe configuration index and the cell-specific subframe cycle/offset, see 3GPP TS 36.211. In

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates whether the sounding reference signal (SRS) of a UE and the ACK/NACK or scheduling request (SR) on the PUCCH are allowed to use the same time resources for simultaneous transmission. If this parameter is set to BOOLEAN_FALSE, simultaneous transmission is not NO allowed. In this situation, the UE discards the SRS and only transmits the ACK/NACK or SR on the PUCCH. If this parameter is set to BOOLEAN_TRUE, simultaneous transmission is allowed. In this situation, the UE transmits truncated ACK/NACK or SR. For details, see 3GPP TS 36.211.

NO

No

LBFD-001001 LBFD-002003

Indicates whether a cell has available SRS resources. If this parameter is set to BOOLEAN_TRUE, the cell has available SRS resources for its UEs. If this parameter is set to BOOLEAN_FALSE, NO the cell has no SRS resources for its UEs. This parameter applies only to cells established on an LBBPd. If cells are established on an LBBPc, the cell has available SRS resources for its UEs by default.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates the TDD SRS configuration to be used. If this parameter is set to EXPERIENCE_FIR ST, the TDD SRS configuration that is designed to preferentially guarantee user experience (for example, beamforming performance) is used. If this NO parameter is set to ACCESS_FIRST, the TDD SRS configuration that is designed to preferentially guarantee the specifications (for example, accessed UEs and CAPs) is used. CAP is short for call attempt per second. This parameter is valid only in TDD mode.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates the cellspecific SRS bandwidth. For details, see 3GPP TS 36.211.

NO

NO

Yes

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the type of the PHICH duration. If this parameter is set to NORMAL, the number of OFDM symbols occupied by the PDCCH can be adaptively adjusted. If this parameter is set to EXTENDED for a cell with a 1.4 MHz bandwidth, the number of OFDM symbols occupied NO by the PDCCH can be 3 or 4. If this parameter is set to EXTENDED for a cell with another bandwidth, the number of OFDM symbols occupied by the PDCCH is 3. For the mapping between the type and the duration, see 3GPP TS 36.211.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates a coefficient that is used to calculate the resources used by the PHICH for the cell. It corresponds to the NO Ng parameter in the protocol. For details on the usage of the Ng parameter, see 3GPP TS 36.211.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the default paging period for the cell. It is also called the discontinuous reception (DRX) period. If the EPC specifies a DRX period for a UE, the UE compares this period with the value of this parameter and uses NO the smaller one as its DRX period. If the EPC does not specify a DRX period, the UE uses the value of this parameter, which is delivered in the system information, as its DRX period. For details, see 3GPP TS 36.304.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-002011 / TDLBFD-002011

Indicates the number of paging occasions (subframes or times of paging) NO contained in a paging cycle. For details, see 3GPP TS 36.304.

NO

No

LBFD-002009 / TDLBFD-002009 LBFD-002011 / TDLBFD-002011

Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS.

YES

No

None

Indicates the number of PUSCH sub-bands. For details, see 3GPP TS 36.211.

NO

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates the hopping mode of the PUSCH. For details, see 3GPP TS 36.211.

NO

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates the hopping offset of the PUSCH. For details, see 3GPP TS 36.211.

NO

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates whether group hopping of the PUSCH is enabled. For details, see 3GPP TS 36.211.

NO

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates the group assignment of the PUSCH. NO For details, see 3GPP TS 36.211.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates whether sequence hopping of the PUSCH is enabled. For details, see 3GPP TS 36.211.

NO

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates the cyclic shift of the PUSCH. NO For details, see 3GPP TS 36.211.

NO

No

LBFD-002003 / TDLBFD-002003 LBFD-002009 / TDLBFD-002009

Indicates whether 64QAM of the PUSCH is enabled. NO For details, see 3GPP TS 36.211. Indicates the local ID of the cell. It YES uniquely identifies a cell within a BS. Indicates the cyclic shift interval of the PUCCH. The cyclic shift interval of the PUCCH can be acquired based on the average delay spread of the cell, and the average delay spread is acquired based on the networking environment. The parameter value DS1_DELTA_SHIF T is not supported NO by the LBBPc. As a result, if the cell is established on an LBBPc but this parameter is set to DS1_DELTA_SHIF T, the value of this parameter will be automatically changed to DS2_DELTA_SHIF T when put into effect. For details, see 3GPP TS 36.211.

NO

No

LOFD-001006 / TDLOFD-001006

YES

No

LBFD-001001 / TDLBFD-001001

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates the number of resource indexes allocated to SRIs and semipersistent ACKs at NO the RRC layer for the FDD cell. If this parameter is set to 0, UEs may fail to access the cell.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates the number of RBs allocated to the CQIs at the RRC layer of FDD cell.

NO

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-002003 / TDLBFD-002003

Indicates the cell global ID of the external CDMA2000 cell. It uniquely identifies a CDMA2000 cell around the globe. For details, see the CellGlobalIdCDMA2 000 IE defined in section 6.3.4 of 3GPP TS 36.331. The cell global ID (CGI) of an external CDMA2000 HRPD cell is 128 bits or 32 hexadecimal digits YES in length. A 16 decimal-digit CGI is still synchronized between the M2000 and the eNodeB in the current version, but is incompatible with the protocol and will be removed from later versions. Therefore, avoid using 16 decimaldigit CGIs. In the new configuration of a 32 hexadecimaldigit CGI, if the 16 hexadecimal digits

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the mobile country code of the external CDMA2000 cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external CDMA2000 cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the cell global ID of the neighboring CDMA2000 HRPD cell. It uniquely identifies a CDMA2000 HRPD cell around the globe. For details, see the CellGlobalIdCDMA2 000 IE defined in section 6.3.4 of 3GPP TS 36.331. The cell global ID (CGI) of an external CDMA2000 HRPD YES cell is 128 bits or 32 hexadecimal digits in length. A 16 decimal-digit CGI is still synchronized between the M2000 and the eNodeB in the current version, but is incompatible with the protocol and will be removed from later versions. Therefore, avoid using 16 decimaldigit CGIs. In the new configuration of a 32 hexadecimal-

YES

No

LOFD-001021

Indicates whether handovers of UEs to the associated NO neighboring cell are prohibited.

NO

No

LOFD-001021 LOFD-002002

Indicates whether to permit or prohibit removal of the NO neighboring relationship by ANR.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the priority of the neighboring cell during blind handovers. Blind handover is a process in which the eNodeB instructs a UE to hand over to a specified neighboring cell without NO measurements. There are 32 priorities altogether. The priority has a positive correlation with the value of this parameter. Note that the value 0 indicates that blind handovers to the neighboring cell are prohibited. Indicates whether this neighboring cell is automatically NO discovered by the ANR algorithm.

NO

No

LBFD-002018 / TDLBFD-002018

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the name NO of the local cell.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the name of the neighboring NO CDMA2000 HRPD cell.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the neighboring CDMA2000 band class. Signals on a frequency within the band class can be YES obtained by UEs. For details, see the BandclassCDMA20 00 IE defined in 3GPP 36.331 6.3.4. Indicates the neighboring CDMA2000 frequency of the serving cell. For YES details, see the IE CDMA2000CarrierInfo in the 3GPP 36.331 6.3.4 protocol.

YES

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803 LOFD-002002

YES

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803 LOFD-002002

Indicates the frequency-specific offset of the local cell to the neighboring CDMA2000 cell on the frequency. A larger value of this parameter leads to NO a higher probability of triggering measurement reports. For details, see the QOffsetRangeInterR AT IE defined in 3GPP 36.331 6.3.4.

NO

No

LOFD-001021 LOFD-002002

Indicates whether to set the size of the CDMA2000 search window. If this NO parameter is set to NOT_CFG, the default size (8) is used.

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001021

Indicates the size of the CDMA2000 search window. UEs search for pilots for neighboring CDMA2000 cells within the time NO period specified by this parameter. For details, see the MeasObjectCDMA2 000 IE defined in 3GPP TS 36.331. Indicates the mobile country code of the external cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists of three digits. YES The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists of three digits. YES The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

NO

No

LBFD-001001 LOFD-001021

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the eNodeB identity of the external EUTRAN cell. It uniquely identifies an eNodeB within a PLMN. The 28-bit EUTRAN cell identity is comprised of the cell identity and the eNodeB identity YES (represented by the most significant 20 bits). The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413. Indicates the cell identity of the external E-UTRAN cell. It uniquely identifies a cell within an eNodeB. The 28-bit EUTRAN cell identity is comprised of the cell identity (represented by the YES least significant eight bits) and the eNodeB identity. The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413.

YES

No

LOFD-001036 LOFD-001037

YES

No

LOFD-001036 LOFD-001037

Indicates the mobile country code of the external E-UTRAN cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external E-UTRAN cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the identity of the external GERAN YES cell. It uniquely identifies a GERAN cell within a PLMN.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the LAC of the external YES GERAN cell.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the mobile country code of the external cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists of three digits. YES The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists of three digits. YES The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the mobile country code of the external GERAN cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external GERAN cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the ID of the external UTRAN cell. It uniquelly identifies a cell in a PLMN. The 28-bit ID of the external UTRAN cell consists of a 12-bit RNC ID (indicated by RncId) and a 16bit RNC cell ID YES (indicated by RncCellId). The formula for calculating the ID of the external UTRAN cell is as follows: External UTRAN cell ID = RNC ID x 65536 + RNC cell ID. Indicates the mobile country code of the external UTRAN cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external UTRAN cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the mobile country code of the external UTRAN cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates the mobile network code of the external UTRAN cell that is shared among multiple operators. A PLMN ID is comprised of an MCC and an MNC. YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the cell global ID of the external CDMA2000 cell. It uniquely identifies a CDMA2000 cell around the globe. For details, see the CellGlobalIdCDMA2 000 IE defined in section 6.3.4 of 3GPP TS 36.331. The cell global ID (CGI) of an external CDMA2000 HRPD cell is 128 bits or 32 hexadecimal digits YES in length. A 16 decimal-digit CGI is still synchronized between the M2000 and the eNodeB in the current version, but is incompatible with the protocol and will be removed from later versions. Therefore, avoid using 16 decimaldigit CGIs. In the new configuration of a 32 hexadecimaldigit CGI, if the 16 hexadecimal digits Indicates the band class on which the external CDMA2000 NO cell operates. For details, see 3GPP TS 36.331.

YES

No

LOFD-001021

YES

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803 LOFD-002002

Indicates the frequency on which the external CDMA2000 cell NO operates. For details, see 3GPP TS 36.331.

YES

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803 LOFD-002002

Indicates the scrambling code, which is used as the physical cell NO identifier of the external CDMA2000 cell. Indicates the type of the external CDMA2000 cell. By default, the cell is a CDMA2000 HRPD cell. Note that the cell global identity of a NO CDMA2000 1xRTT cell consists of 6 decimal digits, and that of a CDMA2000 HRPD cell consists of 16 decimal digits. Indicates the mobile country code of the external cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists of three digits. NO The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LBFD-001001 / TDLBFD-001001 LOFD-001021 LBFD-00201803 / TDLBFD-00201803

NO

No

LOFD-001021 LBFD-00201803

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the mobile network code of the external cell. A PLMN ID is comprised of an MCC and an MNC. The MCC consists of three digits. NO The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001036 / TDLOFD-001036 LOFD-001037 / TDLOFD-001037

Indicates the name of the external NO CDMA2000 cell.

NO

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803 LOFD-002002

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the cell global ID of the neighboring CDMA2000 1xRTT cell. It uniquely identifies a CDMA2000 1xRTT cell around the globe. For details, see the CellGlobalIdCDMA2 000 IE defined in section 6.3.4 of 3GPP TS 36.331. The cell global ID (CGI) of an external CDMA2000 1xRTT YES cell is 47 bits or 12 hexadecimal digits in length. A 12 hexadecimal-digit CGI is converted from a string of binary digits, from the left of which the BASEID occupies bits 1 to 16, the SID occupies bits 17 to 31, the NID occupies bits 32 to 47, and 0 always occupies bit 48. If the length of the BASEID, SID, and

YES

No

LOFD-001021

Indicates whether handovers of UEs to the associated NO neighboring cell are prohibited.

NO

No

LOFD-001021 LOFD-002002

Indicates whether to permit or prohibit removal of the NO neighboring relationship by ANR.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the priority of the neighboring cell during blind handovers. Blind handover is a process in which the eNodeB instructs a UE to hand over to a specified neighboring cell without NO measurements. There are 32 priorities altogether. The priority has a positive correlation with the value of this parameter. Note that the value 0 indicates that blind handovers to the neighboring cell are prohibited. Indicates whether this neighboring cell is automatically NO discovered by the ANR algorithm.

NO

No

LBFD-002018 / TDLBFD-002018

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the name NO of the local cell.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the name of the neighboring NO cell.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the neighboring CDMA2000 band class. Signals on a frequency within the band class can be YES obtained by UEs. For details, see the BandclassCDMA20 00 IE defined in 3GPP 36.331. Indicates the absolute priority of the CDMA2000 band class to be used during cell reselection. The value 0 indicates the lowest priority. Frequencies used for different RATs must be assigned different cell reselection priorities. The information is contained in SIB8. For details, see 3GPP TS 36.331.

YES

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803 LOFD-002002

NO

NO

No

LOFD-001021 LBFD-00201803 / TDLBFD-00201803

Indicates the minimum RX level required for a neighboring cell on a frequency in the CDMA2000 band class to become a candidate for reselection if the priority of the frequency is higher than that of the serving frequency. After measurements NO are started for neighboring cells on a frequency in the band class, the UE reselects to a neighboring cell only if the RX level of the cell is higher than the value specified by this parameter for a timeto-trigger. For details, see 3GPP TS 36.304 5.2.4.5.

NO

No

LBFD-00201803

Indicates the minimum RX level required for a neighboring cell on a frequency in the CDMA2000 band class to become a candidate for reselection if the priority of the frequency is lower than that of the serving frequency. After measurements are started for neighboring cells on NO a frequency in the band class, the UE reselects to a cell on the frequency only if the RX level of the serving cell is lower than a specified threshold and that of the cell is higher than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.304 5.2.4.5. Indicates the mobile country code of the external cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345.

NO

No

LBFD-00201803

YES

No

LOFD-001020 / TDLOFD-001020

Indicates the mobile network code of the external cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the cell ID of the external GERAN cell. It uniquely identifies a GERAN cell within the area specified YES by the location area identity (LAI). An LAI consists of the MCC, MNC, and LAC.

YES

No

LOFD-001020 / TDLOFD-001020

YES

No

LOFD-001020 / TDLOFD-001020

Indicates the LAC of the external GERAN cell. It YES uniquely identifies a location within a PLMN.

YES

No

LOFD-001020 / TDLOFD-001020

Indicates whether to set the routing area code (RAC) of the external GERAN cell. This parameter NO is required if the external GERAN cell supports packet switched (PS) services.

NO

No

LOFD-001020

Indicates the routing NO area code.

NO

No

LOFD-001020 / TDLOFD-001020

Indicates the GERAN band indicator. If the GERAN ARFCN is a value in the range of 512 to 810, the value of this parameter is used NO to indicate whether the GERAN frequency is in the 1800MHz band or the 1900MHz band. For details, see 3GPP TS 36.331.

YES

No

LOFD-001020 / TDLOFD-001020 LOFD-001023 / TDLOFD-001023 LOFD-001034 / TDLOFD-001034 LOFD-001046 / TDLOFD-001046 LOFD-001073 / TDLOFD-001073

Indicates the GERAN BCCH ARFCN. For details, NO see 3GPP TS 45.005.

YES

No

LOFD-001020

Indicates the network color code (NCC) of GERAN. It is operator-specific and identifies a network within the whole country. The base NO transceiver station identity code (BSIC) consists of the NCC and the base station color code (BCC). For details, see 3GPP TS 23.003.

YES

No

LOFD-001020

Indicates the base station color code (BCC) of the external GERAN cell. The base transceiver station NO identity code (BSIC) consists of the BCC and the network color code (NCC). For details, see 3GPP TS 23.003. Indicates whether the cell supports the dual transmission mode. If the cell supports the dual transmission mode, both CS and PS NO services can be handed over to the cell. Otherwise, only the CS service or the PS service can be handed over to the cell.

YES

No

LOFD-001020

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001046 / TDLOFD-001046

Indicates the name of the external NO GERAN cell.

NO

No

LOFD-001020 / TDLOFD-001020

Indicates whether the external GERAN cell supports single radio voice call continuity (SRVCC) for both CS and PS NO services. If this parameter is set to BOOLEAN_FALSE, the cell supports only SRVCC for CS services.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-001046 / TDLOFD-001046

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the mobile country code of the neighboring GERAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the mobile network code of the neighboring GERAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345.

YES

No

LOFD-001020 / TDLOFD-001020

YES

No

LOFD-001020 / TDLOFD-001020

Indicates the LAC of the GERAN neighboring cell. It YES uniquely identifies a location within a PLMN.

YES

No

LOFD-001020 / TDLOFD-001020

Indicates the cell ID of the GERAN neighboring cell. It uniquely identifies a GERAN cell within the area specified YES by the location area identity (LAI). An LAI consists of the MCC, MNC, and LAC. Indicates whether to permit or prohibit removal of the NO neighboring relationship by ANR. Indicates whether handovers of UEs to the neighboring cell are prohibited.

YES

No

LOFD-001020 / TDLOFD-001020

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

NO

NO

No

LOFD-002002

Indicates the priority of the neighboring cell during blind handovers. Blind handover is a process in which the eNodeB instructs a UE to hand over to a specified neighboring cell. NO There are 32 priorities altogether. The priority has a positive correlation with the value of this parameter. Note that the value 0 indicates that blind handovers to the neighboring cell are not allowed.

NO

No

LBFD-002018 / TDLBFD-002018

Indicates whether this neighboring cell is automatically NO discovered by the ANR algorithm.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the name NO of the local cell.

NO

No

LOFD-002001 LOFD-002002

Indicates the name of the GERAN NO neighboring cell.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the ID of the eNodeB, which uniquely identifies NO an eNodeB within a PLMN. Indicates the start time of the latest RIM procedure towards the neighboring GERAN cell.

NO

Yes

LOFD-001053 / TDLOFD-001053

NO

NO

Yes

LOFD-001053 / TDLOFD-001053

Indicates the time of the latest RIM request received by NO the neighboring GERAN cell.

NO

Yes

LOFD-001053 / TDLOFD-001053

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates a GERAN carrier frequency group. In the cell reselection procedure, the GERAN carrier frequencies are YES organized in groups and the cell reselection parameters are provided per group of GERAN carrier frequencies.

YES

No

LOFD-001020 / TDLOFD-001020 LOFD-002002

Indicates the standard that is supported by the current carrier frequency group.

NO

YES

No

LOFD-001020 / TDLOFD-001020

Indicates the first ARFCN value in the GERAN carrier NO frequency group. For details, see 3GPP TS 36.331.

YES

No

LOFD-001020 / TDLOFD-001020 LBFD-00201803 / TDLBFD-00201803

Indicates the GERAN band indicator. If the GERAN ARFCN is a value in the range of 512 to 810, the value of this parameter is used NO to indicate whether the GERAN frequency is in the 1800MHz band or the 1900MHz band. For details, see 3GPP TS 36.331. Indicates whether to set the reselection priority of the frequencies in the GERAN carrier frequency group. If the value of this NO parameter is not specified, the UE does not reselect to neighboring cells on the frequencies in the GERAN carrier frequency group.

YES

No

LOFD-001020

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the cell reselection priority of the GERAN carrier frequency group. It is contained in system information block type 7 (SIB7). The UE decides whether to reselect a neighboring cell on a frequency in the GERAN carrier frequency group based on the value of this parameter and the absolute NO priority of the serving cell. If the value of this parameter is larger than the absolute priority of the serving cell, the UE starts measurements on neighboring cells on the frequencies in the GERAN carrier frequency group; then if the signal quality of some neighboring cells meets the related Indicates whether to set the maximum power that the UE can apply to transmission on a frequency in the GERAN carrier NO frequency group. It is used in criteria S to calculate the compensated power. For details, see 3GPP TS 36.104.

NO

No

LBFD-00201803

NO

No

LBFD-00201803

Indicates the maximum power that the UE can apply to transmission on a frequency in the GERAN carrier frequency group. For details, see 3GPP TS 36.331.

NO

NO

No

LBFD-00201803

Indicates the RX level required for a neighboring cell on a frequency in the GERAN carrier frequency group to become a candidate for selection. It is included in criteria S and used in the evaluation for cell selection. During the evaluation for cell reselection, the UE performs the following calculation: Srxlev = NO Measured RSSI value of a neighboring cell on a frequency in the GERAN carrier frequency group Value of this parameter Compensated power. If Srxlev for a neighboring cell is better than a threshold for a timeto-trigger, reselection to the cell is started. For details, see 3GPP

NO

No

LBFD-00201803

Indicates the RX level required for a neighboring cell on a frequency in the GERAN carrier frequency group to become a candidate for reselection if the priority of the frequency is higher than that of the serving frequency. After measurements are started for NO neighboring cells on a frequency in the GERAN carrier frequency group, the UE reselects to a cell on the frequency only if the RX level of the cell is better than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.104.

NO

No

LBFD-00201803

Indicates the RX level required for a neighboring cell on a frequency in the GERAN carrier frequency group to become a candidate for reselection if the priority of the frequency is lower than that of the serving frequency. After measurements are started for neighboring cells on a frequency in the NO GERAN carrier frequency group, the UE reselects to a cell on the frequency only if the RX level of the serving cell is lower than a specified threshold and that of the cell is better than the value specified by this parameter for a timeto-trigger. For details, see 3GPP TS 36.104.

NO

No

LBFD-00201803

Indicates the frequency specific offset of the group of neighboring GERAN carrier frequencies. This parameter is used NO in the decision of the UE to send measurement reports for interRAT handovers. For details, see 3GPP TS 36.331.

NO

No

LOFD-001020 / TDLOFD-001020 LOFD-002002

Indicates whether a BCCH carrier with the specific NCC is permitted for NO monitoring. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the index of the BCCH carrier frequency group. It YES identifies a BCCH carrier frequency group.

YES

No

LBFD-002009 / TDLBFD-002009 LOFD-001020 / TDLOFD-001020

Indicates the GERAN BCCH ARFCN. For details, YES see 3GPP TS 45.005.

YES

No

LBFD-002009 LOFD-002002

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the starting physical cell ID of the intrafrequency YES blacklisted cell. For details, see 3GPP TS 36.331.

YES

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201801 / TDLBFD-00201801

Indicates the name of the intraNO frequency blacklisted cell.

NO

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201801 / TDLBFD-00201801

Indicates the physical cell ID range of the intrafrequency NO blacklisted cell. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201801 / TDLBFD-00201801

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the mobile country code of the E-UTRAN neighboring cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the mobile network code of the E-UTRAN neighboring cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345.

YES

No

LBFD-00201801 / TDLBFD-00201801

YES

No

LBFD-00201801 / TDLBFD-00201801

Indicates the eNodeB identity of the intra-frequency neighboring cell. It uniquely identifies an eNodeB within a PLMN. The 28-bit EUTRAN cell identity is comprised of the cell identity and the eNodeB identity YES (represented by the most significant 20 bits). The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413. Indicates the local identity of the intrafrequency neighboring cell. It uniquely identifies a cell within an eNodeB. The 28-bit E-UTRAN cell identity is comprised of the cell identity (represented by the YES least significant eight bits) and the eNodeB identity. The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413.

YES

No

LBFD-00201801 / TDLBFD-00201801

YES

No

LBFD-00201801 / TDLBFD-00201801

Indicates the cell individual offset for the intra-frequency neighboring cell, which is used in evaluation for handovers. It affects the probability of NO triggering intrafrequency measurement reports. A larger value of this parameter indicates a higher probability. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 / TDLBFD-00201801 LOFD-002005 / TDLOFD-002005

Indicates the offset for the intrafrequency neighboring cell, which is used in evaluation for cell reselections. A larger value of this NO parameter results in a lower probability of cell reselections. This parameter is contained in SIB4. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates whether handovers of UEs to the neighboring cell are prohibited.

NO

NO

No

LBFD-00201801 / TDLBFD-00201801 LOFD-002001 / TDLOFD-002001

Indicates whether to permit or prohibit removal of the NO neighboring relationship by ANR.

NO

No

LOFD-002001 / TDLOFD-002001

Indicates whether this neighboring cell is automatically NO discovered by the ANR algorithm.

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the name NO of the local cell.

NO

No

LBFD-00201801 LOFD-002001

Indicates the name of the intrafrequency neighboring EUTRAN cell. The name is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters: double NO quotation marks ("), commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

NO

No

LBFD-00201801 / TDLBFD-00201801 LOFD-002001 / TDLOFD-002001

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the DL EARFCN of the neighboring cell on the neighboring EUTRAN frequency. The DL EARFCN is calculated by using the following formula: DL carrier frequency (MHz) = Lowest frequency of the DL operating band + 0.1 x (DL EARFCN - Offset used to calculate the DL EARFCN). YES For example, if the DL EARFCN is 3100 in band 7 for a cell, the DL carrier frequency of the cell is calculated as 2620 + 0.1 x (3100 2750) = 2655 MHz. Band 1: DL EARFCN range: 0 to 599, lowest frequency of the DL operating band: 2110; Band 2: DL EARFCN range: 600 to 1199, lowest

YES

No

LBFD-001001 LBFD-00201803 LBFD-00201802

Indicates whether to set the UL EARFCN. If this parameter is set to NOT_CFG, the UL EARFCN is the DL NO EARFCN plus 18000 in FDD mode and is the same as the DL EARFCN in TDD mode. Indicates the UL EARFCN of the neighboring cell on the neighboring EUTRAN frequency. For an FDD cell, if no UL EARFCN is configured, the UL EARFCN equals the sum of the DL EARFCN and 18000. For a TDD cell, the UL EARFCN is calculated by using the following formula: NO UL carrier frequency (MHz) = Lowest frequency of the UL operating band + 0.1 x (UL EARFCN - Offset used to calculate the UL EARFCN). For example, if the UL EARFCN is 21100 in band 7 for a cell, the UL carrier frequency of the cell is calculated as 2500 + 0.1 x (21100 - 20750) = 2535 MHz.

NO

No

LBFD-001001 / TDLBFD-001001 LBFD-00201803 / TDLBFD-00201803 LBFD-00201802 / TDLBFD-00201802

NO

No

LBFD-001001 LBFD-00201803 LBFD-00201802

Indicates whether to set the reselection priority of the neighboring EUTRAN frequency. If the value of this NO parameter is not specified, the UE does not reselect to neighboring cells on the frequency. Indicates the cell reselection priority of the neighboring EUTRAN frequency. It is contained in system information block type 5 (SIB5). The UE decides whether to reselect a neighboring cell on the frequency based on the value of this parameter and the absolute priority of the serving cell. If the value of this NO parameter is larger than the absolute priority of the serving cell, the UE starts measurements on neighboring cells on the frequency; then if the signal quality of some neighboring cells meets the related conditions, the UE starts cell reselection. If the value of this parameter is less

NO

No

LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-00201803

Indicates the time threshold for interfrequency cell reselection. A UE initiates a reselection to the inter-frequency neighboring cell only after the signal quality in the cell is better than that in NO the serving cell for a period defined by this parameter and, in addition, after the UE camps on the serving cell for longer than 1s. This parameter is contained in SIB5. For details, see 3GPP TS 36.331. Indicates whether to set the speeddependent scaling parameters related to cell reselection. If this parameter is NO set to NOT_CFG, speed-dependent cell reselections are not supported by default. Indicates the scaling factor applied to the cell reselection duration for medium-mobility NO UEs. This parameter is delivered in SIB5. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the scaling factor applied to the cell reselection duration for high-mobility NO UEs. This parameter is delivered in SIB5. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the measurement bandwidth of the inter-frequency neighboring cell on the frequency. The setting of this parameter depends on the bandwidth configuration of the cell. In E-UTRAN, a cell bandwidth is NO also expressed in units of resource blocks (RBs). Cell bandwidths 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, and 20 MHz correspond to 6 RBs, 15 RBs, 25 RBs, 50 RBs, 75 RBs, and 100 RBs, respectively.

YES

No

LBFD-001001 LBFD-00201803 LBFD-00201802

Indicates the frequency offset of the neighboring cell on the frequency. It is delivered in system information block type 5 (SIB5). NO It is used in the evaluation for cell reselection and for the triggering and stopping of event A4.

NO

No

LBFD-001001 LBFD-00201803

Indicates the RX level required for a neighboring cell on the frequency to become a candidate for reselection if the priority of the frequency is higher than that of the serving frequency. After measurements are started for NO neighboring cells on the frequency, the UE reselects to a neighboring cell on the frequency only if the RX level of the cell is better than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803

Indicates the minimum RX level required for a neighboring cell on the frequency to become a candidate for reselection if the priority of the frequency is lower than or equal to that of the serving frequency. After measurements are started for neighboring cells on NO the frequency, the UE reselects to a neighboring cell on the frequency only if the RX level of the serving cell is lower than a specified threshold and that of the cell is higher than the value specified by this parameter for a timeto-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803

Indicates the RX level required for a neighboring cell on the frequency to become a suitable cell for selection. It is included in criteria S and used in the evaluation for cell selection. During the evaluation for cell reselection, the UE performs the following calculation: Srxlev = NO Measured RSRP value of a neighboring cell on the frequency Value of this parameter Compensated power. If Srxlev for a cell is better than a threshold for a time-to-trigger, reselection to the cell is started. For details, see 3GPP TS 36.304. Indicates whether to set the maximum power that the UE can apply to transmission on the neighboring EUTRAN frequency. If the value of this NO parameter is not specified, the maximum power is subject to the UE capability. For details, see 3GPP TS 36.101.

NO

No

LBFD-00201803

NO

No

LBFD-00201803

Indicates the maximum power that the UE can apply to transmission on the neighboring EUTRAN frequency. It is used in criteria S to calculate the NO compensated power. If the value of this parameter is not specified, the maximum power is subject to the UE capability. For details, see 3GPP TS 36.101. Indicates the configuration information about the intra-frequency neighboring cell of the serving cell. BitString00: Indicates that certain neighboring cells have the same MBSFN subframe. BitString01: Indicates that all neighboring cells have the same NO MBSFN subframe. BitString10: Indicates that all neighboring cells have mutually different MBSFN subframes. BitString11: Indicates that the serving TDD cells have neighboring cells of different ULDL configurations. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803

NO

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201802 / TDLBFD-00201802

Indicates whether all inter-frequency neighboring cells on this frequency are configured with at least two antenna ports. Set this parameter to TRUE if all interfrequency neighboring cells on NO this frequency are configured with at least two antenna ports. Set this parameter to FALSE if one inter-frequency neighboring cell on this frequency is configured with only one antenna port. Indicates the event to trigger coveragebased interfrequency handovers. This parameter can be set to EventA3, EventA4, or EventA5. If the neighboring EUTRAN frequency and the serving frequency are in the same frequency NO band, event A3 is recommended as it provides better handover performance in this situation. If the neighboring EUTRAN frequency and the serving frequency are in different frequency bands, event A4 or A5 is used.

NO

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201802 / TDLBFD-00201802

NO

No

LBFD-00201802

Indicates the RSRQbased minimum RX level required for a neighboring cell on the frequency to become a candidate for reselection if the RSRQ-based priority of the frequency is higher than that of the serving frequency. After measurements are started for neighboring cells on NO the neighboring EUTRAN frequency, the UE reselects to a neighboring cell on the frequency only if the RSRQbased RX level of the cell is higher than the value specified by this parameter for a timeto-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the RSRQbased minimum RX level required for a neighboring cell on the frequency to become a candidate for reselection if the RSRQ-based priority of the frequency is lower than that of the serving frequency. After measurements are started for neighboring cells on a frequency in the GERAN carrier NO frequency group, the UE reselects to a neighboring cell on the frequency only if the RSRQbased RX level of the serving cell is lower than a specified threshold and that of the cell is higher than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates whether to set the minimum NO required RX level.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the minimum RX level of an interfrequency neighboring cell, which is required for it to become a candidate for cell reselection. It determines the probability of NO triggering cell reselection to interfrequency neighboring cells on the frequency. The value of this parameter is contained in SIB5. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the DL EARFCN of the inter-frequency blacklisted cell. The DL EARFCN is calculated by using the following formula: DL carrier frequency (MHz) = Lowest frequency of the DL operating band + 0.1 x (DL EARFCN - Offset used to calculate the DL EARFCN). For example, if the YES DL EARFCN is 3100 in band 7 for a cell, the DL carrier frequency of the cell is calculated as 2620 + 0.1 x (3100 2750) = 2655 MHz. Band 1: DL EARFCN range: 0 to 599, lowest frequency of the DL operating band: 2110; Band 2: DL EARFCN range: 600 to 1199, lowest frequency of the DL

YES

No

LBFD-00201803 LBFD-00201802

Indicates the starting physical cell ID of the interfrequency YES blacklisted cell. For details, see 3GPP TS 36.331.

YES

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201802 / TDLBFD-00201802

Indicates the name of the interNO frequency blacklisted cell.

NO

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201802 / TDLBFD-00201802

Indicates the physical cell ID range of the interfrequency NO blacklisted cell. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803 LBFD-00201802 / TDLBFD-00201802

Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

YES

No

None

Indicates the mobile country code of the E-UTRAN neighboring cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the mobile network code of the E-UTRAN neighboring cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345.

YES

No

LBFD-00201802 / TDLBFD-00201802

YES

No

LBFD-00201802 / TDLBFD-00201802

Indicates the eNodeB identity of the inter-frequency neighboring cell. It uniquely identifies an eNodeB within a PLMN. The 28-bit EUTRAN cell identity is comprised of the cell identity and the eNodeB identity YES (represented by the most significant 20 bits). The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413. Indicates the local identity of the interfrequency neighboring cell. It uniquely identifies a cell within an eNodeB. The 28-bit E-UTRAN cell identity is comprised of the cell identity (represented by the YES least significant eight bits) and the eNodeB identity. The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413.

YES

No

LBFD-00201802 / TDLBFD-00201802

YES

No

LBFD-00201802

Indicates the cell individual offset for the inter-frequency neighboring cell, which is used in evaluation for handovers. It affects the probability of NO triggering interfrequency measurement reports. A larger value of this parameter indicates a higher probability. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201802 / TDLBFD-00201802 LOFD-002005 / TDLOFD-002005

Indicates the offset for the interfrequency neighboring cell, which is used in evaluation for cell reselections. A larger value of this NO parameter results in a lower probability of cell reselections. This parameter is contained in SIB5. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates whether handovers of UEs to the neighboring cell are prohibited.

NO

NO

No

LBFD-00201802 / TDLBFD-00201802 LOFD-002001 / TDLOFD-002001

Indicates whether to permit or prohibit removal of the NO neighboring relationship by ANR.

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the priority of the neighboring cell during blind handovers. Blind handover is a process in which the eNodeB instructs a UE to hand over to a specified neighboring cell without measurements. There are 32 priorities in total. NO The priority has a positive correlation with the value of this parameter. The value 0 indicates that blind handover is prohibited. Values 17 to 32 are designated for frequency-prioritybased handover, and values 1 to 16 are designated for other handover. Indicates whether this neighboring cell is automatically NO discovered by the ANR algorithm.

NO

No

LBFD-00201802 / TDLBFD-00201802 LBFD-00201803 / TDLBFD-00201803

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the name NO of the local cell.

NO

No

LBFD-00201802 LOFD-002001

Indicates the name of the interNO frequency neighboring cell.

NO

No

LBFD-00201802 / TDLBFD-00201802 LOFD-002001 / TDLOFD-002001

Indicates the mobile country code of the external E-UTRAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the mobile network code of the external E-UTRAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the eNodeB identity of the external EUTRAN cell. It uniquely identifies an eNodeB within a PLMN. The 28-bit EUTRAN cell identity is comprised of the cell identity and the eNodeB identity YES (represented by the most significant 20 bits). The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413.

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the cell identity of the external E-UTRAN cell. It uniquely identifies a cell within an eNodeB. The 28-bit EUTRAN cell identity is comprised of the cell identity (represented by the YES least significant eight bits) and the eNodeB identity. The cell global identity (CGI) of an E-UTRAN cell is comprised of the EUTRAN cell identity and the PLMN ID. For details, see 3GPP TS 36.413.

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the DL EARFCN of the external E-UTRAN cell. The DL EARFCN is calculated by using the following formula: DL carrier frequency (MHz) = Lowest frequency of the DL operating band + 0.1 x (DL EARFCN - Offset used to calculate the DL EARFCN). For example, if the NO DL EARFCN is 3100 in band 7 for a cell, the DL carrier frequency of the cell is calculated as 2620 + 0.1 x (3100 2750) = 2655 MHz. Band 1: DL EARFCN range: 0 to 599, lowest frequency of the DL operating band: 2110; Band 2: DL EARFCN range: 600 to 1199, lowest frequency of the DL Indicates whether to set the UL EARFCN for the external EUTRAN cell. If this parameter is set to NOT_CFG, the UL NO EARFCN is the DL EARFCN plus 18000 in FDD mode and is the same as the DL EARFCN in TDD mode.

YES

No

LBFD-00201801 LBFD-00201802

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the UL EARFCN of the external E-UTRAN cell. For an FDD cell, if no UL EARFCN is configured, the UL EARFCN equals the sum of the DL EARFCN and 18000. For a TDD cell, the UL EARFCN is calculated by using the following formula: UL carrier NO frequency (MHz) = Lowest frequency of the UL operating band + 0.1 x (UL EARFCN - Offset used to calculate the UL EARFCN). For example, if the UL EARFCN is 21100 in band 7 for a cell, the UL carrier frequency of the cell is calculated as 2500 + 0.1 x (21100 - 20750) = 2535 MHz. Band 1: UL Indicates the physical cell ID of the external EUTRAN cell. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201801 LBFD-00201802

NO

YES

No

LBFD-00201801 LBFD-00201802 LBFD-00201803

Indicates the tracking area code (TAC) of the external E-UTRAN cell. Two TAC values 0x0000(0) and 0xFFFE(65534) are reserved according to the NO protocol and will not be used in future versions. Therefore, do not use 0 or 65534 as a TAC value in TAC planning or configuration.

YES

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the name of the external ENO UTRAN cell.

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802

Indicates the cell identity of the local cell. It uniquely identifies a cell within an eNodeB.

YES

YES

No

LBFD-00201803 / TDLBFD-00201803

Indicates the index of the GERAN carrier frequency group. It uniquely YES identifies a GERAN carrier frequency group.

YES

No

LOFD-001019 / TDLOFD-001019

Indicates the mobile country code (MCC) of the operator that shares the neighboring GERAN carrier frequency group. A public land mobile network (PLMN) ID is comprised of an MCC and a mobile YES network code (MNC). The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LBFD-00201803 / TDLBFD-00201803

Indicates the mobile network code (MNC) of the operator that shares the neighboring GERAN carrier frequency group. A public land mobile network (PLMN) ID is comprised of a mobile country code YES (MCC) and an MNC. The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates whether to configure the cell reselection priority of the operator that NO shares the neighboring GERAN carrier frequency group.

YES

No

LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the cell reselection priority of the operator that shares the neighboring GERAN carrier frequency group. If the related SPID configuration is specified, set this priority to the one specified in the SPID configuration. If no related SPID configuration is specified but this parameter is set, NO the eNodeB delivers the cell reselection priorities of all PLMNs supported by a UE by using the IE idleModeMobilityCo ntrolInfo in an RRC Connection Release message to the UE. If no related SPID configuration is specified and this parameter is not set, a UE uses the cell reselection priority of the Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

NO

No

LBFD-00201803 / TDLBFD-00201803

YES

No

None

Indicates the mobile country code of the neighboring UTRAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the mobile network code of the neighboring UTRAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the UTRAN cell ID. It uniquely identifies a cell within a PLMN.The 28-bit ID of the UTRAN cell consists of a 12-bit RNC ID (indicated by RncId) and a 16bit RNC cell ID YES (indicated by RncCellId). The formula for calculating the ID of the external UTRAN cell is as follows: External UTRAN cell ID = RNC ID x 65536 + RNC cell ID.

YES

No

LOFD-001019 / TDLOFD-001019

YES

No

LOFD-001019 / TDLOFD-001019

YES

No

LOFD-001019 / TDLOFD-001019

Indicates whether to allow handover of UEs to the neighboring cell that NO is determined by the neighboring relation. Indicates whether to permit or prohibit removal of the NO neighboring relationship by ANR. Indicates the priority of the neighboring cell during blind handovers. Blind handover is a process in which the eNodeB instructs a UE to hand over to a specified neighboring cell. NO There are 32 priorities altogether. The priority has a positive correlation with the value of this parameter. Note that the value 0 indicates that blind handovers to the neighboring cell are not allowed. Indicates whether this neighboring cell is automatically NO discovered by the ANR algorithm.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-002002

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

NO

No

LBFD-002018 / TDLBFD-002018

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the name NO of the local cell.

NO

No

LOFD-001019

Indicates the name of the UTRAN NO neighboring cell.

NO

No

LOFD-001019 / TDLOFD-001019

Indicates the ID of the eNodeB, which uniquely identifies NO an eNodeB within a PLMN.

NO

Yes

LOFD-001052 / TDLOFD-001052

Indicates the RNC ID of the neighboring UTRAN cell. This RNC ID must be the same NO as the 12 bits on the left of the corresponding UTRAN cell ID. Indicates the latest updated time of the system information that the eNodeB NO receives from the neighboring UTRAN cell through the RIM procedure. Indicates the time of the latest RIM request received by NO the neighboring UTRAN cell.

NO

Yes

LOFD-001052 / TDLOFD-001052

NO

Yes

LOFD-001052 / TDLOFD-001052

NO

Yes

LOFD-001052 / TDLOFD-001052

Indicates the cell identity of the local cell. It uniquely identifies a cell within an eNodeB.

YES

YES

No

LBFD-00201803 / TDLBFD-00201803

Indicates the DL UARFCN of the neighboring cell operating on the UTRAN frequency. The UARFCN range in each FDD frequency band is shown as follows: Band 1: Normal UARFCNs: [10562-10838] Special UARFCNs: none Band 2: Normal UARFCNs: [9662-9938] YES Special UARFCNs: (412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687) Band 3: Normal UARFCNs: [1162-1513] Special UARFCNs: none Band 4: Normal UARFCNs: [1537-1738] Special UARFCNs: (1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087) Band 5: Indicates the mobile country code (MCC) of the neighboring UTRAN cell. A public land mobile network (PLMN) ID is comprised of an MCC and a mobile network code (MNC). YES The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345.

YES

No

LOFD-001019 / TDLOFD-001019

YES

No

LBFD-00201803 / TDLBFD-00201803

Indicates the mobile network code (MNC) of the neighboring UTRAN cell. A public land mobile network (PLMN) ID is comprised of a mobile country code (MCC) and an YES MNC. The MCC consists of three digits. The MNC consists of two to three digits. For example, if the MCC is 123 and the MNC is 45, then the PLMN ID is 12345. Indicates whether to configure the cell reselection priority of the operator that NO shares the neighboring UTRAN frequency.

YES

No

LBFD-00201803 / TDLBFD-00201803

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the cell reselection priority of the operator that shares the neighboring UTRAN frequency. If the related SPID configuration is specified, set this priority to the one specified in the SPID configuration. If no related SPID configuration is specified but this parameter is set, the eNodeB delivers NO the cell reselection priorities of all PLMNs supported by a UE by using the IE idleModeMobilityCo ntrolInfo in an RRC Connection Release message to the UE. If no related SPID configuration is specified and this parameter is not set, a UE uses the cell reselection priority of the neighboring UTRAN Indicates the cell ID of the local cell. It uniquely identifies a YES cell within an eNodeB.

NO

No

LBFD-00201803 / TDLBFD-00201803

YES

No

None

Indicates the DL UARFCN of the neighboring cell on the UTRAN frequency. The UARFCN range in each FDD frequency band is shown as follows: Band 1: Normal UARFCNs: [10562-10838] Special UARFCNs: none Band 2: Normal UARFCNs: [9662-9938] YES Special UARFCNs: (412,437,462,487,5 12,537,562,587,612 ,637,662,687) Band 3: Normal UARFCNs: [1162-1513] Special UARFCNs: none Band 4: Normal UARFCNs: [1537-1738] Special UARFCNs: (1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087) Band 5: Indicates the working mode supported by the NO UTRAN in the current UARFCN. Indicates the TDD/FDD mode of the inter-RAT UTRAN.

YES

No

LBFD-002009 LOFD-001019 LOFD-002002

NO

No

LOFD-001019 / TDLOFD-001019 LBFD-00201803 / TDLBFD-00201803

NO

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-002002

Indicates whether to set the UL UARFCN of the cell on the UTRAN frequency. If the value of this parameter is not specified, the default UL UARFCN is used. For an UTRAN FDD cell, the way to calculate the default UL UARFCN varies depending on whether the DL frequency is a normal or special NO one. The default UL UARFCN is calculated as follows if the DL frequency is a normal one: Band 1: UL UARFCN = DL UARFCN - 950; Band 2: UL UARFCN = DL UARFCN - 400; Band 3: UL UARFCN = DL UARFCN - 475; Band 4: UL

NO

No

LOFD-001019 LBFD-00201803

Indicates the UL UARFCN of the neighboring cell on the UTRAN frequency. The UARFCN range in each FDD frequency band is shown as follows: Band 1: Normal UARFCNs: [9612-9888] Special UARFCNs: none Band 2: Normal UARFCNs: [9262-9538] NO Special UARFCNs: (12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287) Band 3: Normal UARFCNs: [937-1288] Special UARFCNs: none Band 4: Normal UARFCNs: [1312-1513] Special UARFCNs: (1662, 1687, 1712, 1737, 1762, 1787, 1812, 1837, 1862) Band 5: Indicates whether to set the priority of a cell assigned with NO the UARFCN used in cell reselection to UTRAN.

NO

No

LOFD-001019 LBFD-00201803 LOFD-002002

NO

No

LBFD-00201803 / TDLBFD-00201803

The UE decides whether to reselect a neighboring cell on the UTRAN frequency based on the value of this parameter and the absolute priority of the serving cell. If the value of this parameter is larger than the absolute priority of the serving cell, the UE starts measurements on neighboring cells on NO the UTRAN frequency; then if the signal quality of some neighboring cells meets the related conditions, the UE starts cell reselection. If the value of this parameter is smaller than the absolute priority of the serving cell, the UE starts the measurements only when the signal quality of the Indicates the maximum power that the UE can apply to transmission on the UTRAN frequency. NO It is used in criteria S to calculate the compensated power. For details, see 3GPP TS 25.104.

NO

No

LBFD-00201803 LBFD-002009

NO

No

LBFD-00201803

Indicates the frequency offset of the cell on the UTRAN frequency. It determines the probability of NO triggering measurement reports for event B1. For details, see 3GPP TS 36.331.

NO

No

LOFD-001019 LOFD-002002

Indicates the minimum quality level required for a cell on the UTRAN frequency to become a candidate for reselection. This parameter is applied only to reselection to UTRAN FDD cells. NO A neighboring cell on the UTRAN frequency can become a candidate for reselection only when the signal quality of the cell is better than the value of this parameter.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the RX level required for a neighboring cell on the UTRAN frequency to become a candidate for selection. It is included in criteria S and used in the evaluation for cell selection. During the evaluation for cell reselection, the UE performs the following calculation: Srxlev = NO Measured RSRP value of a neighboring cell on the frequency Value of this parameter Compensated power. If Srxlev for a neighboring cell is better than a threshold for a timeto-trigger, reselection to the cell is started. For details, see 3GPP TS 25.304.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the minimum RX level required for a neighboring cell on the UTRAN frequency to become a candidate for reselection if the priority of the frequency is higher than that of the serving frequency. After measurements are started for NO neighboring cells on the UTRAN frequency, the UE reselects to a neighboring cell on the frequency only if the RX level of the cell is higher than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803

Indicates the minimum RX level required for a neighboring cell on the UTRAN frequency to become a candidate for reselection if the priority of the frequency is lower than that of the serving frequency. After measurements are started for neighboring cells on the UTRAN NO frequency, the UE reselects to a neighboring cell on the frequency only if the RX level of the serving cell is lower than a specified threshold and that of the cell is higher than the value specified by this parameter for a timeto-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803

Indicates the RSRQbased minimum RX level required for a neighboring cell on the frequency to become a candidate for reselection if the RSRQ-based priority of the frequency is higher than that of the serving frequency. After measurements are started for NO neighboring cells on the UTRAN frequency, the UE reselects to a neighboring cell on the frequency only if the RSRQ-based RX level of the cell is higher than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the RSRQbased minimum RX level required for a neighboring cell on the frequency to become a candidate for reselection if the RSRQ-based priority of the frequency is lower than that of the serving frequency. After measurements are started for neighboring cells on NO the frequency, the UE reselects to a cell on the frequency only if the RSRQ-based RX level of the serving cell is lower than a specified threshold and that of the cell is higher than the value specified by this parameter for a time-to-trigger. For details, see 3GPP TS 36.331.

NO

No

LBFD-00201803 / TDLBFD-00201803

Indicates the packet switched (PS) priority of the neighboring UTRAN frequency, that is, the priority for the neighboring UTRAN frequency to carry PS services. It is used in coveragebased handovers. When UtranFreqLayerMea sSwitch is turned on: If there are both high and low PSpriority UTRAN NO frequencies, the high PS-priority UTRAN frequencies are preferentially measured; if there are only low PSpriority UTRAN frequencies, these low PS-priority UTRAN frequencies are measured. If UtranFreqLayerBlin dSwitch is turned on, the target cell for a blind coveragebased handover is

NO

No

LOFD-001019 / TDLOFD-001019

Indicates the circuit switched (CS) priority of the neighboring UTRAN frequency, that is, the priority for the neighboring UTRAN frequency to carry CS services. It is used in blind handovers for CSFB to UTRAN. If UtranFreqLayerBlin dSwitch is turned on, the target cell NO for a blind handover is preferentially selected from the neighboring UTRAN cells on high CSpriority frequencies. If all neighboring UTRAN cells are on low CS-priority frequencies, the target cell is selected from all neighboring UTRAN cells. Indicates the mobile country code of the external UTRAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345.

NO

No

LOFD-001019 / TDLOFD-001019

YES

No

LOFD-001019 / TDLOFD-001019

Indicates the mobile network code of the external UTRAN cell. The PLMN consists of the MCC and the MNC. The MCC consists YES of three digits. The MNC consists of two to three digits. For example, MCC = 123, MNC = 45, PLMN = 12345. Indicates the ID of the external UTRAN cell. It uniquely identifies a UTRAN cell within a PLMN.The 28-bit ID of the external UTRAN cell consists of a 12-bit RNC ID (indicated by RncId) and a 16YES bit RNC cell ID (indicated by RncCellId). The formula for calculating the ID of the external UTRAN cell is as follows: External UTRAN cell ID = RNC ID x 65536 + RNC cell ID.

YES

No

LOFD-001019 / TDLOFD-001019

YES

No

LOFD-001019

Indicates the type of NO the UTRAN cell.

NO

No

LOFD-001019 / TDLOFD-001019

Indicates the DL UARFCN of the external UTRAN cell. The UARFCN range in each FDD frequency band is shown as follows: Band 1: Normal UARFCNs: [10562-10838] Special UARFCNs: none Band 2: Normal UARFCNs: [9662-9938] Special UARFCNs: (412,437,462,487,5 NO 12,537,562,587,612 ,637,662,687) Band 3: Normal UARFCNs: [1162-1513] Special UARFCNs: none Band 4: Normal UARFCNs: [1537-1738] Special UARFCNs: (1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087) Band 5: Normal UARFCNs: [4357-4458]

YES

No

LOFD-001019

Indicates whether to set the UL UARFCN for the external UTRAN cell. If the value of this parameter is not specified, the default DL UARFCN is used. For an UTRAN FDD cell, the way to calculate the default UL UARFCN varies depending on whether the DL frequency is a normal or special NO one. The default UL UARFCN is calculated as follows if the DL frequency is a normal one: Band 1: UL UARFCN = DL UARFCN - 950; Band 2: UL UARFCN = DL UARFCN - 400; Band 3: UL UARFCN = DL UARFCN - 475; Band 4: UL

NO

No

LOFD-001019

Indicates the UL UARFCN of the external UTRAN cell. The UARFCN range in each FDD frequency band is shown as follows: Band 1: Normal UARFCNs: [9612-9888] Special UARFCNs: none Band 2: Normal UARFCNs: [9262-9538] Special UARFCNs: (12, 37, 62, 87, 112, NO 137, 162, 187, 212, 237, 262, 287) Band 3: Normal UARFCNs: [937-1288] Special UARFCNs: none Band 4: Normal UARFCNs: [1312-1513] Special UARFCNs: (1662, 1687, 1712, 1737, 1762, 1787, 1812, 1837, 1862) Band 5: Normal UARFCNs: [4132-4233] Indicates the RNC ID of the external UTRAN cell. The most left 12 bits of NO external UTRAN cell ID must be set to the RNC ID of the external cell. Indicates whether to set the routing area code (RAC) of the external UTRAN cell. This parameter must be set to CFG NO if the external UTRAN cell supports packet switched (PS) services.

NO

No

LOFD-001019

YES

No

LOFD-001019

NO

No

LOFD-001019

Indicates the routing NO area code.

NO

No

LOFD-001019

Indicates the primary DL scrambles of the NO external UTRAN cell. For details, see 3GPP TS 25.331.

YES

No

LOFD-001019 / TDLOFD-001019

Indicates the LAC of the external UTRAN NO cell.

YES

No

LOFD-001019 / TDLOFD-001019 LOFD-001022 / TDLOFD-001022 LOFD-001033 / TDLOFD-001033 LOFD-001043 / TDLOFD-001043 LOFD-001072 / TDLOFD-001072

Indicates the name of the external NO UTRAN cell.

NO

No

LOFD-001019 / TDLOFD-001019

Indicates whether the external UTRAN cell supports single radio voice call continuity (SRVCC) for both CS and PS NO services. If this parameter is set to BOOLEAN_FALSE, the cell supports only SRVCC for CS services.

NO

No

LOFD-001019

Indicates the threshold above which a neighboring cell is added to a serving cell by ANR. The threshold is the percentage of the number of successful handovers to the total number of handovers from the serving cell to the NO neighboring cell. In this version, this parameter is no longer used internally although it supports setting synchronization between the M2000 and the eNodeB. Avoid using this parameter as it will be removed from later versions.

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the threshold for removing a neighbor relationship with a cell by ANR based on the handover success rate. The threshold is the percentage of the number of successful handovers to the total number of handovers from the local cell to the neighboring cell. NO For example, an external cell is configured as a neighboring cell for all cells under an eNodeB, and this neighboring cell permits automatic removal of the neighboring relationship by ANR. If the success rate of handovers from each cell under the eNodeB to this neighboring cell is lower than or Indicates the threshold for the total number of handovers to an intra-RAT neighboring cell, above which ANR NO begins to evaluate the removal of the neighboring relation in the case of a low handover success rate.

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the period during which the total number of handovers to an intra-RAT neighboring cell is measured by ANR NO to evaluate the removal of the neighboring relation in the case of a low handover success rate. Indicates the number of periodic measurement NO reports sent for fast ANR.

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the interval at which periodic NO measurement reports are sent for fast ANR.

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the fast ANR checking timer. When the timer is expired, the NO eNodeB automatically checks whether to disable fast ANR.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the reference signal received power (RSRP) threshold for intra-RAT fast ANR. If the signal quality in a neighboring ENO UTRAN cell reported by the UE is lower than the threshold, the cell is not automatically added as an external cell of the eNodeB. Indicates the maximum allowed number of UEs that perform intra-RAT measurements for fast ANR. After the number of UEs performing intraRAT measurements NO for fast ANR reaches the maximum number, intra-RAT measurements for fast ANR will not be performed on other UEs. Indicates the maximum allowed number of UEs that perform inter-RAT measurements for fast ANR. After the number of UEs performing interRAT measurements NO for fast ANR reaches the maximum number, inter-RAT measurements for fast ANR will not be performed on other UEs.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002002

Indicates the minimum required number of UEs that have performed measurements for NO fast ANR before intra-RAT fast ANR can be automatically disabled. Indicates the minimum required number of UEs that have performed measurements for NO fast ANR before inter-RAT fast ANR can be automatically disabled. Indicates the mode for optimizing neighboring relations. If this parameter is set to FREE, neighboring relations are optimized automatically by ANR. If this NO parameter is set to CONTROLLED, neighboring relations to be added or removed are reported to the M2000 and then subject to manual processing for optimization.

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002002

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the period during which the number of handovers are measured for neighboring relation removal from a neighbor relation table (NRT). In a measurement period for neighboring relation NO removal, when the total number of handovers from a cell exceeds the threshold for neighboring relation removal, the neighboring cells that are not detected by UEs are removed from the NRT. Indicates the number of handovers above which neighboring relations are to be removed from a neighbor relation table (NRT). In a measurement period for neighboring relation NO removal, when the total number of handovers from a cell exceeds the value of this parameter, the neighboring cells that are not detected by UEs are removed from the NRT.

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the switch used to enable or disable proactive PCI collision detection. Within a specified duration after this switch is turned on, the eNodeB delivers measurement configurations for NO proactive PCI collision detection to UEs that meet specific requirements. Then, the eNodeB starts the detection based on the measurement reports from the UEs. Indicates the start time of the active PCI collision detection. If the stop time is earlier than NO or the same as the start time, the stop time is assumed to be the time of the next day. Indicates the stop time of the active PCI collision detection. If the stop time is earlier than NO or the same as the start time, the stop time is assumed to be the time of the next day.

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002001 / TDLOFD-002001

NO

No

LOFD-002001 / TDLOFD-002001

Indicates the received signal code power (RSCP) threshold for fast ANR with UTRAN. If the signal quality in a neighboring UTRAN cell NO reported by the UE is lower than the threshold, the cell is not automatically added as an external cell of the eNodeB. Indicates the received signal strength indicator (RSSI) threshold for fast ANR with GERAN. If the signal quality in a neighboring NO GERAN cell reported by the UE is lower than the threshold, the cell is not automatically added as an external cell of the eNodeB. Indicates the pilot strength threshold for fast ANR with CDMA2000 1xRTT. If the signal quality in a neighboring CDMA2000 1xRTT NO cell reported by the UE is lower than the threshold, the cell is not automatically added as an external cell of the eNodeB.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the pilot strength threshold for fast ANR with CDMA2000 HRPD. If the signal quality in a neighboring CDMA2000 HRPD NO cell reported by the UE is lower than the threshold, the cell is not automatically added as an external cell of the eNodeB. Indicates the switch for the algorithm for periodically updating cell IDs. If this parameter is set to BOOLEAN_TRUE, cell IDs are periodically NO updated, inserted into the system information, and broadcast to the associated UEs once the time at which the algorithm begins to take effect is reached. Indicates the time at which the algorithm for periodically updating cell IDs begins to take effect. If the switch for the algorithm is turned on, cell IDs are periodically NO updated, inserted into the system information, and broadcast to the associated UEs once the time specified by this parameter is reached.

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

NO

No

LBFD-002009 / TDLBFD-002009

NO

No

LBFD-002009 / TDLBFD-002009

Indicates the period NO of updating cell IDs.

NO

No

LBFD-002009 / TDLBFD-002009

Indicates the collective switch used to enable or disable handover and CS fallback algorithms. Flash CS fallback to UTRAN: If the switch for CS fallback to UTRAN NO is turned off, this switch does not take effect; Flash CS fallback to GERAN: If the switch for CS fallback to GERAN is turned off, this switch does not take effect.

NO

No

LBFD-00201801 / TDLBFD-00201801 LBFD-00201802 / TDLBFD-00201802 LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023 LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035 LOFD-001043 / TDLOFD-001043 LOFD-001044 / TDLOFD-001044 LOFD-001046 / TDLOFD-001046 LBFD-00201805

Indicates the switches corresponding to the inputs based on which the eNodeB determines handover policies. Note that EutranVoipCapSwit ch will be removed NO in the later versions. In this version, the setting of this switch is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this switch.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021 LOFD-001022 / TDLOFD-001022 LOFD-001023 / TDLOFD-001023 LOFD-001033 / TDLOFD-001033 LOFD-001034 / TDLOFD-001034 LOFD-001035 LOFD-001043 / TDLOFD-001043 LOFD-001044 / TDLOFD-001044 LOFD-001045 / TDLOFD-001045 LOFD-001046 / TDLOFD-001046

Indicates the DL ICIC algorithm switch. There are four states. DlIcicSwitch_OFF_ ENUM:Indicates that DL ICIC is disabled. DlIcicDynamicSwitc h_ON_ENUM:Indic ates that dynamic DL ICIC is enabled. DlIcicStaticSwitch_ ON_ENUM:Indicate s that static DL ICIC NO is enabled. DlIcicReuse3Switch _ON_ENUM: This state will be removed in the later versions. In this version, the setting of this state is still synchronized between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this state.

NO

No

LBFD-00202201 / TDLBFD-00202201 LOFD-00101401 / TDLOFD-00101401

Indicates the ANR algorithm switch. Switches related to ANR are described as follows: IntraRatEventAnrS witch: If this switch is turned on, intraRAT event-triggered ANR is enabled to construct and optimize intra-RAT neighboring relations by triggering intra-RAT handover events. IntraRatFastAnrSwit NO ch: If this switch is turned on, intraRAT fast ANR is enabled to construct and optimize intraRAT neighboring relations by performing periodic intra-RAT measurements. IntraRatAnrAutoDel Switch: If both IntraRatEventAnrS witch and this switch are turned on and No Remove of an intra-RAT

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002

Indicates the switch used to enable or disable the redirection algorithm. GeranFlashRedirect Switch: If both this switch and the switch for redirection to GERAN are turned on, fast redirection NO to GERAN is enabled. UranFlashRedirectS witch: If both this switch and the switch for redirection to UTRAN are turned on, fast redirection to UTRAN is enabled.

NO

No

LOFD-001019 / TDLOFD-001019 LOFD-001020 / TDLOFD-001020 LOFD-001021

Indicates the switches for Mobility Robustness Optimization (MRO) algorithms. If the switch for a specific MRO algorithm is enabled, fewer handover failures will occur and the mobility robustness will be improved. If the switch is set to OFF, the corresponding MRO algorithm is disabled. NO IntraFreqMroSwitch: If this switch is turned on, the eNodeB can dynamically adjust the intra-frequency handover parameters to increase the intrafrequency handover success rate; if the switch is turned off, the adjustment is not performed. InterFreqMroSwitch: If this switch is turned on, the

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the switch for the TCP proxy enhancer (TPE) algorithm. The TPE algorithm increases the rates of TCP services by measures such as ACK copying, ACK splitting, and local ACK retransmission. If this switch is NO turned on, the TPE algorithm is enabled. In this situation, the algorithm is valid only for UEs that newly access or reaccess the network. If this switch is turned off, the TPE algorithm is disabled. This parameter will be removed in the later versions. In this version, the setting of this parameter is still synchronized NO between the M2000 and the eNodeB, but it is no longer used internally. Therefore, avoid using this parameter.

NO

No

LBFD-001001 / TDLBFD-001001 LOFD-001026 / TDLOFD-001028

NO

No

LOFD-00101402 / TDLOFD-00101402

Indicates the switch used to enable or disable UL ICIC in the frequency domain. If this switch is set to OFF, UL ICIC in the frequency domain is disabled in the eNodeB cells. If this switch is set to NO STATIC, static UL ICIC in the frequency domain is enabled in the eNodeB cells. If this switch is set to DYNAMIC, dynamic UL ICIC in the frequency domain is enabled in the eNodeB cells. Indicates the location services (LCS) switch. OtdoaSwitch: If the switch is turned on, observed time difference of arrivalNO based (OTDOAbased) positioning is enabled. If the switch is turned off, OTDOA-based positioning is disabled.

NO

No

LBFD-00202202 / TDLBFD-00202202 LOFD-00101402 / TDLOFD-00101402

NO

No

LOFD-001047 / TDLOFD-001047

Indicates the switch for UL flow control over the air interface. If this switch is turned on, the scheduling algorithm is instructed to limit the UL data rate of UEs upon UL transmission congestion. This method prevents UL congestion in the eNodeB, but affects fairness and differentiation for NO combined services. If this switch is turned off, the scheduling algorithm is not notified and therefore no rate restriction is applied to UL data from UEs in the case of UL congestion. In this case, UL congestion may occur in an eNodeB, but fairness and differentiation for

NO

No

None

Indicates the switch for reporting PCI collision alarms. If the switch is turned on, the PCI collision alarm is displayed on the local maintenance terminal (LMT) when a PCI collision among external cells or among NO neighboring cell occurs. If the switch is turned off, the PCI collision alarm is not displayed when such a PCI collision actually occurs. Note that in this situation, the PCI collision still persists. Indicates the switch used to enable or disable the eNodeBlevel energy conservation function. This function is achieved through the symbolbased power amplifier (PA) shutdown. Symbolbased PA shutdown is applicable in single-mode eNodeBs. If this NO function is enabled, the eNodeB shuts down power amplifiers (PAs) on the corresponding RF unit when it detects no signal transmitted on OFDM symbols in DL subframes. This reduces static power consumption and hence conserves energy for the eNodeB.

NO

No

LOFD-002007 / TDLOFD-002007

NO

No

LOFD-001070 / TDLOFD-001070

Indicates the collective switch for the RAN information management (RIM) function. UTRAN_RIM_SWIT CH: Indicates the switch used to enable or disable the RIM procedure that requests eventdriven multiple reports from UTRAN cells. If this switch is turned on, the eNodeB can send NO RANINFORMATIONREQUEST protocol data units (PDUs) to UTRAN cells to request multiple event-driven reports. If this switch is turned off, the eNodeB cannot send RANINFORMATIONREQUEST PDUs to UTRAN cells to request multiple event-driven

NO

No

LOFD-001052 / TDLOFD-001052 LOFD-001053 / TDLOFD-001053

Indicates the ANR algorithm switch in eRAN sharing mode. Related switches are described as follows: NBSLTEPLMNRou ndSwitch: If this switch is turned on, some neighboring eNodeBs provide cells that work in eRAN sharing mode and broadcast their PLMN lists in a round robin (RR) NO manner. In this situation, if IntraRatEventAnrS witch or IntraRatFastAnrSwit ch is turned on for the local eNodeB, the local eNodeB will ask the M2000 for the actual cell global identifier (CGI) and PLMN list for a cell broadcasting PLMNs in an RR manner after the UE reports the CGI of

NO

No

LOFD-002001 / TDLOFD-002001 LOFD-002002 / TDLOFD-002002

Indicates the switch used to enable or disable the UTRAN hierarchy-based measurement algorithm and the UTRAN hierarchybased blindhandover algorithm.If UtranFreqLayerMea sSwitch is turned on, the UTRAN hierarchy-based measurement algorithm takes effect for NO measurements related to coveragebased and CSFBtriggered handovers from the E-UTRAN to the UTRAN. If UtranFreqLayerBlin dSwitch is turned on, the UTRAN hierarchy-based blind-handover algorithm takes effect for coveragebased and CSFBtriggered handovers from the E-UTRAN Indicates the interval for detecting license alarms. During this interval, the eNodeB detects license control NO items and reports license alarms if the condition for generating license alarms is met.

NO

No

LBFD-002018 / TDLBFD-002018

NO

No

None

Indicates the threshold for generating license alarms. A license alarm is generated if the proportion of the actually used value to the allocated value of the license control item exceeds this threshold.

NO

NO

No

None

Indicates the interval for clearing license alarms. During this interval, the eNodeB detects license control NO items and clears license alarms if the condition for clearing license alarms is met. Indicates the threshold for clearing license alarms. A license alarm is cleared if the proportion of the NO actually used value to the allocated value of the license control item is below this threshold. Indicates the proportion of the UL licensed traffic to the total licensed traffic of the eNodeB. The total licensed traffic is NO the sum of UL and DL licensed traffic. If this parameter is set to 100, there is no DL licensed traffic, affecting service admission.

NO

No

None

NO

No

None

NO

No

LOFD-001036 / TDLOFD-001036

Indicates the mode of traffic sharing between the operators in eRAN sharing scenarios. If this parameter is set to SHARING, all the operators share the total traffic of the eNodeB without proportional limits. If this parameter is set NO to DEDICATE, all the operators share the total traffic of the eNodeB based on specific proportions. However, the vacant traffic of an operator can be used by other operators. Indicates the proportion of the traffic used by the first operator to the total licensed traffic of the eNodeB when all operators share traffic based on specific NO proportions in eRAN sharing scenarios and the eNodeB does not work in independent mode. This parameter cannot be set to 0 if the operator has been configured.

NO

No

LOFD-001036 / TDLOFD-001036

NO

No

LOFD-001036 / TDLOFD-001036

Indicates the proportion of the traffic used by the second operator to the total licensed traffic of the eNodeB when all operators share traffic based on specific proportions NO in eRAN sharing scenarios and the eNodeB does not work in independent mode. This parameter cannot be set to 0 if the operator has been configured. Indicates the proportion of the traffic used by the third operator to the total licensed traffic of the eNodeB when all operators share traffic based on specific NO proportions in eRAN sharing scenarios and the eNodeB does not work in independent mode. This parameter cannot be set to 0 if the operator has been configured.

NO

No

LOFD-001036 / TDLOFD-001036

NO

No

LOFD-001036 / TDLOFD-001036

Indicates the proportion of the traffic used by the fourth operator to the total licensed traffic of the eNodeB when all operators share traffic based on specific proportions NO in eRAN sharing scenarios and the eNodeB does not work in independent mode. This parameter cannot be set to 0 if the operator has been configured. Indicates the proportion of the traffic shared by the first operator to the total licensed traffic of the eNodeB when all operators NO share traffic based on specific proportions in eRAN sharing scenarios and the eNodeB does not work in independent mode. Indicates the proportion of the traffic shared by the second operator to the total licensed traffic of the eNodeB when all operators share NO traffic based on specific proportions in eRAN sharing scenarios and the eNodeB does not work in independent mode.

NO

No

LOFD-001036 / TDLOFD-001036

NO

No

LOFD-001036 / TDLOFD-001036

NO

No

LOFD-001036 / TDLOFD-001036

Indicates the proportion of the traffic shared by the third operator to the total licensed traffic of the eNodeB when all operators NO share traffic based on specific proportions in eRAN sharing scenarios and the eNodeB does not work in independent mode. Indicates the proportion of the traffic shared by the fourth operator to the total licensed traffic of the eNodeB when all operators share NO traffic based on specific proportions in eRAN sharing scenarios and the eNodeB does not work in independent mode. Indicates the period of measurement for MRO. During the period, the number of handovers is measured and abnormal scenarios (including premature NO handover, delayed handover, and pingpong handover) are identified. After the period elapses, the eNodeB makes a decision on parameter adjustment.

NO

No

LOFD-001036 / TDLOFD-001036

NO

No

LOFD-001036 / TDLOFD-001036

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the threshold for enabling MRO based on the handover success rate. MRO is applied and parameter NO adjustment is started only if the success rate of handovers from the local cell to a neighboring cell is below this threshold. Indicates the threshold of the number of handovers required for enabling MRO. MRO is applied and parameter adjustment is NO started only if the number of handovers from the local cell to a neighboring cell reaches this threshold. Indicates the time threshold for pingpong handover. If a UE is handed over back to the source cell after staying in the target cell for a period shorter than NO this threshold, the eNodeB decides that a ping-pong handover occurs based on the history information about this UE.

NO

No

LOFD-002005 / TDLOFD-002005

NO

No

LOFD-002005 / TDLOFD-002005

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the threshold for the percentage of intraRAT ping-pong handovers. If the percentage of intraRAT ping-pong handovers exceeds the threshold, parameter NO adjustment is performed to reduce the number of pingpong handovers. If the percentage is lower than the threshold, parameter adjustment is not performed. Indicates the threshold for identifying abnormal coverage of the serving cell. Weak coverage or no coverage in the overlapping area between cells leads to radio link failures or handover failures. Within a NO measurement period, if the number of such failures between the serving cell and a neighboring cell exceeds this threshold, the eNodeB does not tune MRO-related parameters of the neighboring cell.

NO

No

LOFD-002005 / TDLOFD-002005

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the reference signal received power (RSRP) threshold for a serving cell. The threshold is used to identify abnormal coverage in a serving cell. When a UE successfully reaccesses a network after a radio link failure (RLF) or handover failure, the UE submits an RLF NO report. In the report, if the RSRP value of the serving cell is less than the RSRP threshold for the serving cell and the RSRP value of a neighboring cell is less than the RSRP threshold for neighboring cells, abnormal coverage exists in the overlapping area between the serving cell and this neighboring cell. If

NO

No

LOFD-002005 / TDLOFD-002005

Indicates the reference signal received power (RSRP) threshold for neighboring cells, which is used to identify abnormal coverage between a serving cell and its neighboring cells. When a UE successfully reaccesses a network after a radio link failure (RLF) or handover failure, the UE NO submits an RLF report. In the report, if the RSRP value of the serving cell is less than the RSRP threshold for the serving cell and the RSRP value of a neighboring cell is less than the RSRP threshold for neighboring cells, abnormal coverage exists in the overlapping area between the serving cell and this Indicates the index of a simulated load configuration. One BS can store 10 YES simulated load configurations, which are identified by the indexes. Indicates the RB usage threshold of a simulated load configuration. If the RB usage of a cell NO is below this threshold, the simulated load scheduling is performed.

NO

No

LOFD-002005 / TDLOFD-002005

YES

No

None

NO

No

None

Indicates the power usage threshold of a simulated load configuration. If the power usage of a NO cell is below this threshold, the simulated load scheduling is performed. Indicates the reporting period for simulated load. The NO value 0 indicates that simulated load is not reported. Indicates the measurement period for simulated load. The value 0 NO indicates that simulated load is not measured. Indicates the switch that is used to control whether to enable and disable the frequencyselective scheduling in simulated load configuration. If the NO switch is set to ON, the frequencyselective scheduling is enabled. If the switch is set to OFF, the frequencydiversity scheduling is used. Indicates whether to enable or disable NO the TCP ACK control algorithm.

NO

No

None

NO

No

None

NO

No

None

NO

No

None

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the maximum downlink throughput for the NO TCP ACK control algorithm.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the timer length for the TCP ACK control algorithm. This timer can be used to control traffic of NO the ACKs to uplink TCP packets, therefore preventing traffic bursts in the downlink.

NO

No

LBFD-002008 / TDLBFD-002008

Indicates the time delay of the frame start time for all TDD E-UTRAN NO cells under the eNodeB to the time of the reference clock.

NO

No

None

Indicates the number of ports that NO enable TCP acceleration. Indicates port 1 to which TPE is to be applied. Indicates port 2 to which TPE is to be applied. Indicates port 3 to which TPE is to be applied. Indicates port 4 to which TPE is to be applied. NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

Indicates port 5 to which TPE is to be applied. Indicates port 6 to which TPE is to be applied. Indicates port 7 to which TPE is to be applied. Indicates port 8 to which TPE is to be applied. Indicates port 9 to which TPE is to be applied.

NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

NO

NO

No

LOFD-001026 / TDLOFD-001028

Indicates port 10 to which TPE is to be NO applied. Indicates port 11 to which TPE is to be NO applied. Indicates port 12 to which TPE is to be NO applied. Indicates port 13 to which TPE is to be NO applied. Indicates port 14 to which TPE is to be NO applied. Indicates port 15 to which TPE is to be NO applied. Indicates port 16 to which TPE is to be NO applied. Indicates port 17 to which TPE is to be NO applied.

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

Indicates port 18 to which TPE is to be NO applied. Indicates port 19 to which TPE is to be NO applied. Indicates port 20 to which TPE is to be NO applied.

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

NO

No

LOFD-001026 / TDLOFD-001028

Indicates the mapping identifier.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the type of the peer device, which can be an SNO GW or a neighboring eNodeB. Indicates whether to use one transmission resource group for all S-GWs or neighboring eNodeBs. If this parameter is set to YES, the eNodeB uses one transmission resource group for NO all S-GWs or all neighboring eNodeBs. If this parameter is set to NO, the eNodeB uses a unique transmission resource group for each S-GW or each neighboring eNodeB.

YES

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the peer device, which can be an SGW or neighboring eNodeB. If the peer device is an S-GW, this parameter must be set to the S-GW NO ID. If the peer device is a neighboring eNodeB, this parameter must be set to the neighboring eNodeB ID.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the target transmission resource group. Indicates the subrack number of the target transmission resource group.

NO

NO

No

LOFD-002004 / TDLOFD-002004

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the slot number of the target NO transmission resource group.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the bear type of the transmission resource group.

NO

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the target transmission resource group.

NO

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the type of sub-board on the board where a NO transmission resource group is established.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the number of the port where a transmission resource group is carried.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the type of port where a transmission NO resource group is carried.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the name of the SON security YES parameter group.

YES

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the ID of the IKE proposal.

NO

YES

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec NO proposal.

YES

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the application type of the SON security parameter group.

NO

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the IKE protocol version.

NO

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the exchange mode of IKEv1. There are two exchange modes: main mode and aggressive mode. In main mode, keys are exchanged separately from identity information. This protects identity information and hence enhances security. The aggressive NO mode does not protect identity information, but is useful in some network environments. If the IKE proposal uses the preshared key (PSK) authentication method, the fully qualified domain name (FQDN) is supported in main mode but not in aggressive mode. Indicates the preshared key. Both ends must use the NO same preshared key in negotiation.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

YES

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the dead NO peer detection (DPD) function.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the dead peer detection (DPD) idle time. If the local end does not receive encrypted packets for a time defined by this parameter, it sends a DPD message to perform NO dead peer detection. However, the exact time at which the eNodeB sends DPD messages varies depending on network environment. Indicates the interval at which the eNodeB sends DPD frames. However, the exact interval at NO which the eNodeB sends DPD frames varies depending on network environment. Indicates the maximum allowed number of DPD frame retransmissions after a dead peer detection (DPD) failure.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the perfect forward secrecy (PFS) value. In the second phase of IPSec negotiation, PFS enables the eNodeB to use a key that is not derived from the first-phase key, ensuring that the two keys are independent of each other. According to PFS, each key protects a unique set of data. NO The elements used to generate a key are not reusable, preventing the disclosure of a key from affecting security of other keys. If the parameter is set to PFS_GROUP1 or PFS_GROUP2 at the local eNodeB, the peer device must launch a PFS exchange when initiating IPSec negotiation. During Indicates the application mode of the IPSec SA lifetime. The value GLOBAL indicates that this lifetime applies to all IPSec SAs of the eNodeB, while the value NO LOCAL indicates that this lifetime applies only to the IPSec SAs generated using the IPSec proposal specified in the same MO.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the lifetime of an IPSec SA. An IPSec SA becomes invalid if its lifetime elapses. Before an IPSec SA becomes invalid, IKE establishes a new IPSec SA through negotiation. Before a new IPSec SA is established, the old IPSec SA is still used to ensure communication NO security. Once the negotiation is complete, the new IPSec SA is immediately used. IPSec SA negotiation takes some time. To prevent SA updates from affecting communication security, a lifetime longer than 900 seconds is recommended. Indicates the effective traffic of the IPSec policy specified in the same MO.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the ID of the operator.

NO

YES

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the ID of the IPv6 MME.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first signaling IPv6 address of the IPv6 MME, which is to be used as the first NO peer IPv6 address for an automatically set up IPv6 SCTP link on the S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 SCTP link that is set up using the first signaling IPv6 address of the IPv6 MME.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPv6 IKE peer that performs IPv6 IKE negotiation with NO the eNodeB when SIGIP1SECFLAG is set to ENABLE.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SIGIP1SECFLAG is set to ENABLE. This IPv6 IPSec NO proposal is required for IPv6 IPSec negotiation between the IPv6 MME and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second signaling IPv6 address of the IPv6 MME, which is to be used as the NO second peer IPv6 address for an automatically set up IPv6 SCTP link on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004 LBFD-002021 / TDLBFD-002021 LBFD-00202103 / TDLBFD-00202103

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 SCTP link that is set up using the second signaling IPv6 address of the IPv6 MME.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPv6 IKE peer that performs IPv6 IKE negotiation with NO the eNodeB when SIGIP2SECFLAG is set to ENABLE.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SIGIP2SECFLAG is set to ENABLE. This IPv6 IPSec NO proposal is required for IPv6 IPSec negotiation between the IPv6 MME and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local port number of the IPv6 MME, which is to be used as the peer port number NO for an automatically set up IPv6 SCTP link on the S1 interface. Indicates the description of the MME6. NO

YES

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004

Indicates the ID of the operator that owns the IPv6 MME.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the compliance protocol release of the MME. The value of this parameter must be the same as the actual compliance protocol release of the MME. The eNodeB sends S1 messages complying with the protocol release NO specified by this parameter. If the parameter value is different from the actual compliance protocol release of the MME, the way in which the MME handles these message is subject to the MME implementation.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the MME ID.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first signaling IP address of the MME, which is to be used as the NO first peer IP address for an automatically set up SCTP link on the S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the SCTP link that is set up using the first signaling IP address of the MME.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW between which and the eNodeB an IPSec tunnel can be automatically set up for the SCTP link NO using the first signaling IP address of the MME. The SeGW performs IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when FIRSTIPSECFLAG is set to ENABLE. NO This IPSec proposal is required for IPSec negotiation between the MME and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second signaling IP address of the MME, which is to be used as the second NO peer IP address for an automatically set up SCTP link on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the SCTP link that is set up using the second signaling IP address of the MME.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW between which and the eNodeB an IPSec tunnel can be automatically set up for the SCTP link NO using the second signaling IP address of the MME. The SeGW performs IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SECIPSECFLAG is set to ENABLE. NO This IPSec proposal is required for IPSec negotiation between the MME and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local port number of the MME, which is to be used as the peer NO port number for an automatically set up SCTP link on the S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the description of the MME.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that owns the MME.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the compliance protocol release of the MME. The value of this parameter must be the same as the actual compliance protocol release of the MME. The eNodeB sends S1 messages complying with the protocol release NO specified by this parameter. If the parameter value is different from the actual compliance protocol release of the MME, the way in which the MME handles these message is subject to the MME implementation. Indicates the cabinet number of the board where the NO S1 service IP address is located. Indicates the subrack number of the board where the NO S1 service IP address is located. Indicates the slot number of the board where the S1 NO service IP address is located.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the S1 service IP address.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the S1 service IP address of the eNodeB, which is to be used as the local IP NO address for an automatically set up IP path on an S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IP path that is set up using the S1 service IP address of the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local IP address used when IPSECFLAG is set to ENABLE. NO The eNodeB uses this IP address in IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the PING detection to check the connectivity of an automatically set up IP path.If the PING detection is disabled in the firewall located in the transport network or in the CN equipment, a NO detection failure is resulted, which will cause the reestablishment of the S1 interface and disrupt services in the cell. Therefore, this parameter must be set to DISABLE under such scenarios.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the S1 service IPv6 YES address.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO S1 service IP address is located. Indicates the subrack number of the board where the NO S1 service IPv6 address is located. Indicates the slot number of the board where the S1 NO service IPv6 address is located.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the S1 service IPv6 address of the eNodeB, which is to be used as the local NO IPv6 address for an automatically set up IPv6 path on an S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 path that is set up using the S1 service IPv6 address of the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local IPv6 address used when SERVIPSECFLAG is set to ENABLE. NO The eNodeB uses this IPv6 address in IPv6 IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the PING detection check the connectivity of an automatically set up IPv6 path.If the PING detection is disabled in the firewall located in the transport network or in the CN equipment, a NO detection failure is resulted, which will cause the reestablishment of the S1 interface and disrupt services in the cell. Therefore, this parameter must be set to DISABLE under such scenarios.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that NO owns the S1 service IPv6 address.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO S1 signaling IP address is located. Indicates the subrack number of the board where the NO S1 signaling IP address is located. Indicates the slot number of the board where the S1 NO signaling IP address is located. Indicates the ID of the S1 signaling IP address.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first S1 signaling IP address of the eNodeB, which is to be used as the first NO local IP address for an automatically set up SCTP link on an S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the SCTP link that is set up using the first S1 signaling IP address of the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the first local IP address used when LOCIPSECFLAG is set to ENABLE. The NO eNodeB uses this IP address in IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second S1 signaling IP address of the eNodeB, which is to be used as the NO second local IP address for an automatically set up SCTP link on an S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the SCTP link that is set up using the second S1 signaling IP address of the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second local IP address used when SECIPSECFLAG is set to ENABLE. The NO eNodeB uses this IP address in IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the SCTP port number of the eNodeB, which is to be used as the local NO SCTP port number for an automatically set up SCTP link on an S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the minimum value of the retransmission timeout (RTO). According to the SCTP protocol, if the calculated RTO is less than this NO parameter value, the round trip delay is set to this parameter value to reduce the probability of retransmission timeout. Indicates the maximum value of the retransmission timeout (RTO). According to the SCTP protocol, it is NO the upper limit for the doubling operation of the retransmission timeout timer. Indicates the initial value of the Retransmission TimeOut (RTO). It is used as the initial NO value when calculating the retransmission timeout in the SCTP protocol.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

For details about the RtoAlpha parameter, see RFC4960. Indicates the value of RtoAlpha. It is used as smooth factor of the round-trip delay calculation in the NO SCTP protocol. In a new estimation, (RtoAlpha/100) is taken from a new measurement, and 1-(RtoAlpha/100) is taken from the last estimation. For details about the RtoBeta parameter, see RFC4960. Indicates the value of RtoBeta. It is used as smooth factor of the round-trip delay calculation in the NO SCTP protocol. In a new estimation, (RtoAlpha/100) is taken from the offset gain, and 1(RtoBeta/100) is taken from the last estimation.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the heartbeat interval, corresponding to the HBINTER parameter specified in RFC4960. SCTP periodically transmits heartbeat messages to an idle destination address to detect the NO reachability. According to RFC4960, the actual interval at which heartbeat messages are transmitted equals the parameter value (HBINTER) plus the retransmission timeout (RTO). Indicates the maximum number of retransmissions on the SCTP link. If the number of retransmissions on the SCTP link NO reaches this parameter value, this SCTP link is considered broken and the eNodeB reports a link failure alarm. Indicates the maximum number of retransmissions over a path. When the number of retransmissions over a path exceeds the value of this parameter, the path NO is regarded as failed if no heartbeat acknowledgment is received. If multiple paths are used, path switching is automatically performed.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to calculate the checksum of each message to be transmitted. If this parameter is set to ENABLE, the eNodeB calculates the checksum. If the NO calculated checksum is different from that contained in the message, the local eNodeB does not transmit the message. Indicates whether to calculate the checksum of each received message. If this parameter is set to ENABLE, the eNodeB calculates the checksum. If the NO calculated checksum is different from that contained in the message, the local eNodeB discards the message. Indicates the type of the checksum NO calculation. Indicates whether to switch back to the primary path upon restoration of the NO automatically set up SCTP link on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the number of consecutive heartbeat messages that must be transmitted on the primary path before the eNodeB NO can switch back to the primary path. This parameter is valid only when SWITCHBACKFLA G is set to ENABLE. Indicates the time interval that one end of SCPT link has to wait before it can send an SACK message in response to data reception. A larger NO value of this parameter indicates a longer time interval between the reception of data and the sending of the corresponding SACK message.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that owns the S1 signaling IP address.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the S1 signaling IPv6 address.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO S1 signaling IPv6 address is located.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the slot number of the board where the S1 NO signaling IPv6 address is located. Indicates the slot number of the board where the S1 NO signaling IPv6 address is located.

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first S1 signaling IPv6 address of the eNodeB, which is to be used as the first NO local IPv6 address for an automatically set up IPv6 SCTP link on an S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 SCTP link that is set up using the first S1 signaling IPv6 address of the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the first local IPv6 address used when SIGIP1SECFLAG is set to ENABLE. The NO eNodeB uses this IPv6 address in IPv6 IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second S1 signaling IPv6 address of the eNodeB, which is to be used as the NO second local IPv6 address for an automatically set up IPv6 SCTP link on an S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004 LBFD-002021 / TDLBFD-002021 LBFD-00202103 / TDLBFD-00202103

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 SCTP link that is set up using the second S1 signaling IPv6 address of the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second local IPv6 address used when SIGIP2SECFLAG is set to ENABLE. The NO eNodeB uses this IPv6 address in IPv6 IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the SCTP port number of the eNodeB, which is to be used as the local SCTP port number NO for an automatically set up IPv6 SCTP link on an S1 interface. Indicates the minimum retransmission timeout (RTO) value of an IPv6 SCTP link. The time that a NO link connectivity check takes has a positive correlation with the value of this parameter. Indicates the maximum RTO value of an IPv6 SCTP link. The time that a link NO connectivity check takes has a positive correlation with the value of this parameter. Indicates the initial RTO value of an IPv6 SCTP link. The time that a link connectivity check NO takes has a positive correlation with the value of this parameter. Indicates the Alpha value for RTO for an IPv6 SCTP link. A larger value of this parameter NO indicates a lower sensitivity of the IPv6 SCTP link to the time delay. For details, see RFC4960.

YES

No

LOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the Beta value for RTO for an IPv6 SCTP link. A larger value of this parameter NO indicates a lower sensitivity of the IPv6 SCTP link to the time delay. For details, see RFC4960. Indicates the heartbeat interval of the IPv6 SCTP link. The status of an IPv6 SCTP link is checked by each end sending heartbeat messages to the other end. If one end receives one heartbeat acknowledgment, then it considers the IPv6 SCTP link as NO connected. However, if one end has transmitted heartbeat messages for a number greater than the MAXASSOCRETR value but has not received any heartbeat acknowledgments, then it considers the IPv6 SCTP link as broken.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the maximum number of retransmissions over an IPv6 SCTP link. If this IPv6 SCTP link has multiple paths, then this IPv6 SCTP link is also called an IPv6 SCTP association and this parameter indicates the maximum number of NO retransmissions over an IPv6 SCTP association. When the number of retransmissions on the association exceeds the value of this parameter, the eNodeB considers the IPv6 SCTP link as broken and reports a link failure alarm. Indicates the maximum number of retransmissions over a path. If the number of retransmissions over a path exceeds the value of this parameter but no NO response message is received, the eNodeB considers this path as unreachable, and switches to another path if multihoming is used.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to calculate the checksum of each message to be transmitted. If the calculated checksum of a message is different NO from the checksum contained in the message, the eNodeB considers this message to have bit errors and does not transmit the message. Indicates whether to check the NO checksum of each received message. Indicates the checksum calculation algorithm. NO

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to switch back to the primary path when the primary path is restored. When the primary path is unreachable, the eNodeB switches to NO the secondary path. This parameter is used to set whether the eNodeB switches back to the primary path when the primary path is restored.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the number of consecutive heartbeat response messages that must be detected over the primary path of an IPv6 SCTP link before the eNodeB can switch back to this primary path. NO After the primary path is restored and the number of consecutive heartbeat response messages reaches the value of this parameter, the eNodeB switches back to the primary path.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that owns the S1 signaling IPv6 address.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the service gateway (S-GW). A maximum of 128 SYES GWs can establish S1 user plane connections with each eNodeB.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first service IP address of the S-GW, which is to be used in NO automatic setup of an IP Path on the S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IP path that is set up using the first service IP address of the SGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP1IPSECFL AG is set to NO ENABLE. The SeGW performs IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SERVIP1IPSECFL AG is set to ENABLE. This NO IPSec proposal is required for IPSec negotiation between the S-GW and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second service IP address of the SGW, which is to be NO used in automatic setup of an IP Path on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IP path that is set up using the second service IP address of the SGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP2IPSECFL AG is set to NO ENABLE. The SeGW performs IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SERVIP2IPSECFL AG is set to ENABLE. This NO IPSec proposal is required for IPSec negotiation between the S-GW and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the third service IP address of the S-GW, which is to be used in NO automatic setup of an IP Path on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IP path that is set up using the third service IP address of the SGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP3IPSECFL AG is set to NO ENABLE. The SeGW performs IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SERVIP3IPSECFL AG is set to ENABLE. This NO IPSec proposal is required for IPSec negotiation between the S-GW and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the fourth service IP address of the S-GW, which is to be used in NO automatic setup of an IP Path on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IP path that is set up using the fourth service IP address of the SGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP4IPSECFL AG is set to NO ENABLE. The SeGW performs IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SERVIP4IPSECFL AG is set to ENABLE. This NO IPSec proposal is required for IPSec negotiation between the S-GW and the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the description of the SGW.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that owns the S-GW.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the IPv6 S-GW.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first service IPv6 address of the IPv6 S-GW, which is to NO be used in automatic setup of an IP path on the S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 path that is set up using the first service IPv6 address of the IPv6 S-GW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the security gateway (SeGW) of the serving gateway (S-GW), which performs IKE negotiation with the NO local eNodeB. This parameter is valid only when SERVIP1IPSECFL AG is set to ENABLE.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-003024 / TDLOFD-003024

Indicates the name of the IP security (IPsec) proposal, which is required for IPsec negotiation between the S-GW and the local NO eNodeB. This parameter is valid only when SERVIP1IPSECFL AG is set to ENABLE.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-003024 / TDLOFD-003024

Indicates the second service IPv6 address of the IPv6 S-GW, which is to NO be used in automatic setup of an IPv6 path on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 path that is set up using the second service IPv6 address of the IPv6 S-GW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP2IPSECFL AG is set to NO ENABLE. The SeGW performs IPv6 IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IP security (IPsec) proposal, which is required for IPsec negotiation between the S-GW and the local NO eNodeB. This parameter is valid only when SERVIP2IPSECFL AG is set to ENABLE.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-003024 / TDLOFD-003024

Indicates the third service IPv6 address of the IPv6 S-GW, which is to NO be used in automatic setup of an IPv6 path on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 path that is set up using the third service IPv6 address of the IPv6 S-GW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP3IPSECFL AG is set to NO ENABLE. The SeGW performs IPv6 IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IP security (IPsec) proposal, which is required for IPsec negotiation between the S-GW and the local NO eNodeB. This parameter is valid only when SERVIP3IPSECFL AG is set to ENABLE.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-003024 / TDLOFD-003024

Indicates the fourth service IPv6 address of the IPv6 S-GW, which is to NO be used in automatic setup of an IPv6 path on the S1 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the eNodeB and the SeGW to protect NO data transmission on the IPv6 path that is set up using the fourth service IPv6 address of the IPv6 S-GW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when SERVIP4IPSECFL AG is set to NO ENABLE. The SeGW performs IPv6 IKE negotiation with the eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IP security (IPsec) proposal, which is required for IPsec negotiation between the S-GW and the local NO eNodeB. This parameter is valid only when SERVIP4IPSECFL AG is set to ENABLE.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-003024 / TDLOFD-003024

Indicates the description of the SGW6. Indicates the ID of the operator that owns the IPv6 SGW, by which the eNodeB identifies this IPv6 S-GW.

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO X2 service IP address is located.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the subrack number of the board where the NO X2 service IP address is located. Indicates the slot number of the board where the X2 NO service IP address is located. Indicates the ID of the X2 service IP address.

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the X2 service IP address of the local eNodeB, which is to be used as the local IP NO address for an automatically set up IP path on an X2 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and a neighboring eNodeB to protect NO data transmission on the IP path that is set up using the X2 service IP address of the local eNodeB. Indicates whether to enable the local eNodeB to perform IPSec negotiation with the neighboring eNodeB through an SeGW when IPSECFLAG is set to ENABLE. If this parameter is set to DISABLE, the local NO eNodeB directly negotiates with the neighboring eNodeB. If this parameter is set to ENABLE, the local eNodeB negotiates with the neighboring eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local IP address used when IPSECFLAG is set to ENABLE. NO The local eNodeB uses this IP address in IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when IPSECFLAG and SEGWFLAG are both set to NO ENABLE. The SeGW performs IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the name of the IPSec proposal used when IPSECFLAG and SEGWFLAG are both set to ENABLE. This NO IPSec proposal is required for IPSec negotiation between the local eNodeB and a neighboring eNodeB through the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable Ping detection to check the connectivity of an automatically set up IP path. If the neighboring eNodeB or the NO firewall in the transport network is configured to block Ping packets, set this parameter to disable Ping detection. Otherwise, Ping detection fails.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO X2 signaling IP address is located. Indicates the subrack number of the board where the NO X2 signaling IP address is located.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the slot number of the board where the X2 NO signaling IP address is located. Indicates the ID of the X2 signaling IP address.

YES

No

LOFD-002004 / TDLOFD-002004

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first X2 signaling IP address of the local eNodeB, which is to be used as the first NO local IP address for an automatically set up SCTP link on an X2 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and a neighboring eNodeB to protect NO data transmission on the SCTP link that is set up using the first X2 signaling IP address of the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the local eNodeB to perform IPSec negotiation with the neighboring eNodeB through an SeGW when FIRSTIPSECFLAG is set to ENABLE. If this parameter is set to DISABLE, the NO local eNodeB directly negotiates with the neighboring eNodeB. If this parameter is set to ENABLE, the local eNodeB negotiates with the neighboring eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local IP address used when IPSECFLAG is set to ENABLE. NO The local eNodeB uses this IP address in IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the SeGW used when IPSECFLAG and SEGWFLAG are both set to NO ENABLE. This SeGW performs IKE negotiation with a neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when IPSECFLAG and SEGWFLAG are both set to ENABLE. This NO IPSec proposal is required for IPSec negotiation between the local eNodeB and a neighboring eNodeB through the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second X2 signaling IP address of the local eNodeB, which is to be used NO as the second local IP address for an automatically set up SCTP link on an X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and a neighboring eNodeB to protect NO data transmission on the SCTP link that is set up using the second X2 signaling IP address of the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the local eNodeB to perform IPSec negotiation with the neighboring eNodeB through an SeGW when SECIPSECFLAG is set to ENABLE. If this parameter is set to DISABLE, the NO local eNodeB directly negotiates with the neighboring eNodeB. If this parameter is set to ENABLE, the local eNodeB negotiates with the neighboring eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second local IP address used when SECIPSECFLAG is set to ENABLE. The NO local eNodeB uses this IP address in IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the name of the SeGW used when SECIPSECFLAG and SECSEGWFLAG NO are both set to ENABLE. The SeGW performs IKE negotiation with a neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SECIPSECFLAG and SECSEGWFLAG are both set to NO ENABLE. This IPSec proposal is required for IPSec negotiation between the local eNodeB and the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the SCTP port number of the eNodeB, which is to be used as the local SCTP port number for an automatically set up SCTP link on an X2 interface. If NO the X2SonLinkSetupTy pe parameter in the GlobalProcSwitch MO is set to X2_OVER_S1, this parameter must be set to 36422.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the minimum Retransmission Timeout (RTO) value for the SCTP link. A smaller value of this parameter indicates a shorter NO time required to check link connectivity. The time required to check link connectivity is twice the sum of the new RTO and heartbeat Indicates the maximum RTO value of an SCTP link. A larger value NO indicates a longer period required for checking link connectivity. Indicates the initial value of the Retransmission TimeOut (RTO). It is used as the initial NO value when calculating the retransmission timeout in the SCTP protocol. Indicates the value of RtoAlpha. It is used as smooth factor of the roundtrip delay calculation in the SCTP protocol. In a NO new estimation, (RtoAlpha/100) is taken from a new measurement, and 1-(RtoAlpha/100) is taken from the last estimation.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the value of RtoBeta. It is used as smooth factor of the roundtrip delay calculation in the SCTP protocol. In a NO new estimation, (RtoBeta/100) is taken from the offset gain, and 1(RtoBeta/100) is taken from the last estimation. Indicates the heartbeat interval, corresponding to the HBInter parameter specified in RFC4960. SCTP periodically transmits heartbeat messages to an idle destination address to detect the NO reachability. According to RFC4960, the actual interval at which heartbeat messages are transmitted equals the parameter value (HBInter) plus the retransmission timeout (RTO). Indicates the maximum number of retransmissions on the SCTP link. If the number of retransmissions on the SCTP link NO reaches this parameter value, the eNodeB breaks this SCTP link and reports a link failure alarm.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the maximum number of retransmissions over a path. When the number of retransmissions over a path exceeds the value of this parameter, the path NO is regarded as failed if no heartbeat acknowledgment is received. If multiple paths are used, path switchover is automatically performed. Indicates whether to calculate the checksum of each message to be transmitted. If this parameter is set to ENABLE, the local eNodeB calculates the NO checksum. If the calculated checksum is different from that contained in the message, the local eNodeB does not transmit the message. Indicates whether to calculate the checksum of each received message. If this parameter is set to ENABLE, the local eNodeB calculates the NO checksum. If the calculated checksum is different from that contained in the message, the local eNodeB discards the message.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the type of the checksum NO calculation. Indicates whether to switch back to the primary path of an automatically set up SCTP link when the primary path is NO restored. When the primary path of an SCTP link becomes unreachable, the secondary path takes over. Indicates the number of consecutive heartbeat messages that must be transmitted on the primary path before the eNodeB NO can switch back to the primary path. This parameter is valid only when the SWITCHBACKFLA G parameter is set to ENABLE. Indicates the time interval that one end of SCTP link has to wait before it can send an SACK message in response to the reception of certain data. A larger value NO of this parameter indicates a longer time interval between the reception of data and the sending of the corresponding SACK message.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the identifier of the X2eNodeB.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first signaling IP address of the neighboring eNodeB, which is to be used as the first NO peer IP address for an automatically set up SCTP link on the X2 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and the neighboring eNodeB to protect NO data transmission on the SCTP link that is set up using the first signaling IP address of the neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the neighboring eNodeB to perform IPSec negotiation with the local eNodeB through an SeGW when FIRSTIPSECFLAG is set to ENABLE. If this parameter is set to DISABLE, the NO neighboring eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring eNodeB negotiates with the local eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the first local IP address used when FIRSTIPSECFLAG is set to ENABLE. NO The neighboring eNodeB uses this IP address in IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second signaling IP address of the neighboring eNodeB, which is to be used as the NO second peer IP address for an automatically set up SCTP link on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and the neighboring eNodeB to protect NO data transmission on the SCTP link that is set up using the second signaling IP address of the neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether the neighboring eNodeB is enabled to perform IPSec negotiation with the local eNodeB through an SeGW when SECIPSECFLAG is set to ENABLE. If this parameter is set to DISABLE, the NO neighboring eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring eNodeB negotiates with the local eNodeB through an SeGW. Indicates the second local IP address used when SECIPSECFLAG is set to ENABLE. The NO neighboring eNodeB uses this IP address in IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the SCTP port number of the neighboring eNodeB, which is to be used as the peer SCTP port number for an automatically set up SCTP link on the X2 interface. If NO the X2SonLinkSetupTy pe parameter in the GlobalProcSwitch MO is set to X2_OVER_S1, this parameter must be set to 36422.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the first service IP address of the neighboring eNodeB, which is to NO be used in automatic setup of an IP path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and the neighboring eNodeB to protect NO data transmission on the IP path that is set up using the first service IP address of the neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether the neighboring eNodeB is enabled to perform IPSec negotiation with the local eNodeB through an SeGW when SERVIP1IPSECFL AG is set to ENABLE. If this parameter is set to NO DISABLE, the neighboring eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring eNodeB negotiates with the local eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the first local IP address used when SERVIP1IPSECFL AG is set to ENABLE. The NO neighboring eNodeB uses this IP address in IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second service IP address of the neighboring eNodeB, which is to NO be used in automatic setup of an IP path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and the neighboring eNodeB to protect NO data transmission on the IP path that is set up using the second service IP address of the neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether the neighboring eNodeB is enabled to perform IPSec negotiation with the local eNodeB through an SeGW when SERVIP2IPSECFL AG is set to ENABLE. If this parameter is set to NO DISABLE, the neighboring eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring eNodeB negotiates with the local eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second local IP address used when SERVIP2IPSECFL AG is set to ENABLE. The NO neighboring eNodeB uses this IP address in IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the third service IP address of the neighboring eNodeB, which is to NO be used in automatic setup of an IP path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and the neighboring eNodeB to protect NO data transmission on the IP path that is set up using the third service IP address of the neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether the neighboring eNodeB is enabled to perform IPSec negotiation with the local eNodeB through an SeGW when SERVIP3IPSECFL AG is set to ENABLE. If this parameter is set to NO DISABLE, the neighboring eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring eNodeB negotiates with the local eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the third local IP address used when SERVIP3IPSECFL AG is set to ENABLE. The NO neighboring eNodeB uses this IP address in IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the fourth service IP address of the neighboring eNodeB, which is to NO be used in automatic setup of an IP path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPSec tunnel between the local eNodeB and the neighboring eNodeB to protect NO data transmission on the IP path that is set up using the fourth service IP address of the neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether the neighboring eNodeB is enabled to perform IPSec negotiation with the local eNodeB through an SeGW when SERVIP4IPSECFL AG is set to ENABLE. If this parameter is set to NO DISABLE, the neighboring eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring eNodeB negotiates with the local eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the fourth local IP address used when SERVIP4IPSECFL AG is set to ENABLE. The NO neighboring eNodeB uses this IP address in IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the mobile country code (MCC) of the neighboring NO eNodeB. An MCC consists of three digits. Indicates the mobile network code (MNC) of the neighboring NO eNodeB. An MNC consists of two or three digits.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the neighboring eNodeB. Indicates the description of the X2eNodeB. Indicates the ID of the operator that owns the neighboring eNodeB.

NO

NO

No

LOFD-002004 / TDLOFD-002004

NO

NO

No

LOFD-002004 / TDLOFD-002004

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the compliance protocol release of the NO neighboring eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the X2 service IPv6 YES address.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO X2 service IPv6 address is located. Indicates the subrack number of the board where the NO X2 service IPv6 address is located. Indicates the slot number of the board where the X2 NO service IPv6 address is located.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the X2 service IPv6 address of the local eNodeB, which is to be used as the local NO IPv6 address for an automatically set up IPv6 path on an S1 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and a neighboring IPv6 NO eNodeB to protect data transmission on the IPv6 path that is set up using the X2 service IPv6 address of the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the local eNodeB to perform IPv6 IPSec negotiation with the neighboring IPv6 eNodeB through an SeGW when SERVIPSECFLAG is set to ENABLE. If this parameter is set NO to DISABLE, the local eNodeB directly negotiates with the neighboring IPv6 eNodeB. If this parameter is set to ENABLE, the local eNodeB negotiates with the neighboring IPv6 eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the local IPv6 address used when IPSECFLAG is set to ENABLE. The local eNodeB NO uses this IPv6 address in IPv6 IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPv6 IKE peer used when SERVIPSECFLAG and SERVIPSECGWFL NO AG are both set to ENABLE. The IPv6 IKE peer performs IPv6 IKE negotiation with the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPsec proposal used in IPsec negotiation between the local eNodeB and the security gateway NO (SeGW). This parameter is valid only when IPSECFLAG and SEGWFLAG are both set to ENABLE.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-003024 / TDLOFD-003024

Indicates whether to enable Ping detection to check the connectivity of an automatically set up IP path. If the neighboring eNodeB or the NO firewall in the transport network is configured to block Ping packets, set this parameter to disable Ping detection. Otherwise, Ping detection fails.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that NO owns the X2 service IPv6 address.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the X2 signaling IPv6 address.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the cabinet number of the board where the NO X2 signaling IPv6 address is located.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the subrack number of the board where the NO X2 signaling IPv6 address is located. Indicates the slot number of the board where the X2 NO signaling IPv6 address is located.

NO

No

LOFD-002004 / TDLOFD-002004

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first X2 signaling IPv6 address of the local eNodeB, which is to be used as the first NO local IPv6 address for an automatically set up IPv6 SCTP link on an X2 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and a neighboring IPv6 eNodeB to protect NO data transmission on the IPv6 SCTP link that is set up using the first X2 signaling IPv6 address of the local eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the local eNodeB to perform IPv6 IPSec negotiation with a neighboring IPv6 eNodeB through an SeGW when SIGIP1SECFLAG is set to ENABLE. If this parameter is set NO to DISABLE, the local eNodeB directly negotiates with the neighboring IPv6 eNodeB. If this parameter is set to ENABLE, the local eNodeB negotiates with the neighboring IPv6 eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the first local IPv6 address used when SIGIP1SECFLAG is set to ENABLE. The NO local eNodeB uses this IPv6 address in IPv6 IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPv6 IKE peer used when SIGIP1SECFLAG and SIGIP1SEGWFLAG NO are both set to ENABLE. This IPv6 IKE peer performs IPv6 IKE negotiation with a local IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SIGIP1SECFLAG and SIGIP1SEGWFLAG are both set to NO ENABLE. This IPv6 IPSec proposal is required for IPv6 IPSec negotiation between the local eNodeB and the IPv6 SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second X2 signaling IPv6 address of the local eNodeB, which is to be used NO as the second local IPv6 address for an automatically set up IPv6 SCTP link on an X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004 LBFD-002021 / TDLBFD-002021 LBFD-00202103 / TDLBFD-00202103

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and a neighboring IPv6 eNodeB to protect NO data transmission on the IPv6 SCTP link that is set up using the second X2 signaling IPv6 address of the local eNodeB. Indicates whether to enable the local eNodeB to perform IPv6 IPSec negotiation with a neighboring IPv6 eNodeB through an SeGW when SIGIP2SECFLAG is set to ENABLE. If this parameter is set NO to DISABLE, the local eNodeB directly negotiates with the neighboring IPv6 eNodeB. If this parameter is set to ENABLE, the local eNodeB negotiates with the neighboring IPv6 eNodeB through an SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second local IPv6 address used when SIGIP2SECFLAG is set to ENABLE. The NO local eNodeB uses this IPv6 address in IPv6 IKE negotiation with a peer device.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPv6 IKE peer used when SIGIP2SECFLAG and SIGIP2SEGWFLAG are both set to NO ENABLE. This IPv6 IKE peer performs IPv6 IKE negotiation with a neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec proposal used when SIGIP2SECFLAG and SIGIP2SEGWFLAG are both set to NO ENABLE. This IPv6 IPSec proposal is required for IPv6 IPSec negotiation between the local eNodeB and the IPv6 SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the SCTP port number of the local eNodeB, which is to be used as the local SCTP port number for an automatically set up IPv6 SCTP link on an X2 interface. If NO the X2SonLinkSetupTy pe parameter in the GLOBALPROCSWI TCH MO is set to X2_OVER_S1, this parameter must be set to 36422. Indicates the minimum retransmission timeout (RTO) value of an IPv6 SCTP link. The time that a NO link connectivity check takes has a positive correlation with the value of this parameter.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the maximum RTO value of an IPv6 SCTP link. The time that a link check NO takes has a positive correlation with the value of this parameter. Indicates the initial RTO value of an IPv6 SCTP link. The time that a link connectivity check NO takes has a positive correlation with the value of this parameter. Indicates the Alpha value for RTO for an IPv6 SCTP link. A larger value of this parameter NO indicates a lower sensitivity of the IPv6 SCTP link to the time delay. For details, see RFC4960. Indicates the Beta value for RTO for an IPv6 SCTP link. A larger value of this parameter NO indicates a lower sensitivity of the IPv6 SCTP link to the time delay. For details, see RFC4960.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the heartbeat interval of the IPv6 SCTP link. The status of an IPv6 SCTP link is checked by each end sending heartbeat messages to the other end. If one end receives one heartbeat acknowledgment, then it considers the IPv6 SCTP link as NO connected. However, if one end has transmitted heartbeat messages for a number equal to the MAXASSOCRETR value but has not received any heartbeat acknowledgments, then it considers the IPv6 SCTP link as broken.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the maximum number of retransmissions over an IPv6 SCTP link. If this IPv6 SCTP link has multiple paths, then this IPv6 SCTP link is also called an IPv6 SCTP association and this parameter indicates the maximum number of NO retransmissions over an IPv6 SCTP association. When the number of retransmissions on the association exceeds the value of this parameter, the eNodeB considers the IPv6 SCTP link as broken and reports a link failure alarm. Indicates the maximum number of retransmissions over a path. If the number of retransmissions over a path exceeds the value of this parameter but no response message NO is received, the eNodeB considers this path as unreachable. If the IPv6 SCTP link uses multihoming, that is, multiple paths, the eNodeB switches to another path.

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to calculate the checksum of each message to be transmitted. If the calculated checksum of a message is different NO from the checksum contained in the message, the eNodeB considers this message to have bit errors and does not transmit the message. Indicates whether to check the NO checksum of each received message. Indicates the checksum calculation algorithm. NO

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to switch back to the primary path when the primary path is restored. When the primary path is unreachable, the eNodeB switches to NO the secondary path. This parameter is used to set whether the eNodeB switches back to the primary path when the primary path is restored.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the number of consecutive heartbeat response messages that must be detected over the primary path of an IPv6 SCTP link before the eNodeB can switch back to this primary path. NO After the primary path is restored and the number of consecutive heartbeat response messages reaches the value of this parameter, the eNodeB switches back to the primary path.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the operator that owns the X2 signaling IPv6 address.

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the ID of the neighboring IPv6 eNodeB.

YES

YES

No

LOFD-002004 / TDLOFD-002004

Indicates the first signaling IPv6 address of the neighboring IPv6 eNodeB, which is to be used as the first NO peer IPv6 address for an automatically set up IPv6 SCTP link on the X2 interface.

YES

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and the neighboring IPv6 eNodeB. The IPv6 IPSec tunnel is NO used to protect data transmission on the IPv6 SCTP link that is set up using the first signaling IPv6 address of the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the neighboring IPv6 eNodeB to perform IPv6 IPSec negotiation with the local eNodeB through an SeGW when SIGIP1SECFLAG is set to ENABLE. If this parameter is set NO to DISABLE, the neighboring IPv6 eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring IPv6 eNodeB negotiates with the local eNodeB through an SeGW. Indicates the local IPv6 address used by the neighboring IPv6 eNodeB in IPv6 IKE negotiation with the local eNodeB. The value of this NO parameter is the same as the value of the SIGIKEIP1 parameter in the X2SigIP6 MO configured on the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second signaling IPv6 address of the neighboring IPv6 eNodeB, which is to be used as the NO second peer IPv6 address for an automatically set up IPv6 SCTP link on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004 LBFD-002021 / TDLBFD-002021 LBFD-00202103 / TDLBFD-00202103

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and the neighboring IPv6 eNodeB to protect NO data transmission on the SCTP link that is set up using the second signaling IPv6 address of the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates whether to enable the neighboring IPv6 eNodeB to perform IPv6 IPSec negotiation with the local eNodeB through an SeGW when SIGIP2SECFLAG is set to ENABLE. If this parameter is set NO to DISABLE, the neighboring IPv6 eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the neighboring IPv6 eNodeB negotiates with the local eNodeB through an SeGW. Indicates the local IPv6 address used by the neighboring IPv6 eNodeB in IPv6 IKE negotiation with the local eNodeB. The value of this NO parameter is the same as the value of the SIGIKEIP2 parameter in the X2SigIP6 MO configured on the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the SCTP port number of the neighboring IPv6 eNodeB, which is to be used as the peer SCTP port number for an automatically set up IPv6 SCTP link on the X2 NO interface. If the X2SonLinkSetupTy pe parameter in the GLOBALPROCSWI TCH MO is set to X2_OVER_S1, this parameter must be set to 36422.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the first service IPv6 address of the neighboring IPv6 eNodeB, which is to NO be used in automatic setup of an IPv6 path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and the neighboring IPv6 eNodeB to protect NO data transmission on the IPv6 path that is set up using the first service IPv6 address of the neighboring IPv6 eNodeB. Indicates whether to enable the peer eNodeB to perform IP security (IPsec) negotiation with the local eNodeB through a security gateway (SeGW). This parameter is valid only when SERVIP1IPSECFL AG is set to NO ENABLE. If this parameter is set to DISABLE, the peer eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the peer eNodeB negotiates with the local eNodeB through the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the local IPv6 address used by the neighboring IPv6 eNodeB in IPv6 IKE negotiation with the local eNodeB. The value of this NO parameter is the same as the value of the SERVIKEIP parameter in the X2ServIP6 MO configured on the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the second service IPv6 address of the neighboring IPv6 eNodeB, which is to NO be used in automatic setup of an IPv6 path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and the neighboring IPv6 eNodeB to protect NO data transmission on the IPv6 path that is set up using the second service IPv6 address of the neighboring IPv6 eNodeB. Indicates whether to enable the peer eNodeB to perform IP security (IPsec) negotiation with the local eNodeB through a security gateway (SeGW). This parameter is valid only when SERVIP2IPSECFL AG is set to NO ENABLE. If this parameter is set to DISABLE, the peer eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the peer eNodeB negotiates with the local eNodeB through the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the local IPv6 address used by the neighboring IPv6 eNodeB in IPv6 IKE negotiation with the local eNodeB. The value of this NO parameter is the same as the value of the SERVIKEIP parameter in the X2ServIP6 MO configured on the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the third service IPv6 address of the neighboring IPv6 eNodeB, which is to NO be used in automatic setup of an IPv6 path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and the neighboring IPv6 eNodeB to protect NO data transmission on the IPv6 path that is set up using the third service IPv6 address of the neighboring IPv6 eNodeB. Indicates whether to enable the peer eNodeB to perform IP security (IPsec) negotiation with the local eNodeB through a security gateway (SeGW). This parameter is valid only when SERVIP3IPSECFL AG is set to NO ENABLE. If this parameter is set to DISABLE, the peer eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the peer eNodeB negotiates with the local eNodeB through the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the local IPv6 address used by the neighboring IPv6 eNodeB in IPv6 IKE negotiation with the local eNodeB. The value of this NO parameter is the same as the value of the SERVIKEIP parameter in the X2ServIP6 MO configured on the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

Indicates the fourth service IPv6 address of the neighboring IPv6 eNodeB, which is to NO be used in automatic setup of an IPv6 path on the X2 interface.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates whether to enable automatic setup of an IPv6 IPSec tunnel between the local eNodeB and the neighboring IPv6 eNodeB to protect NO data transmission on the IPv6 path that is set up using the fourth service IPv6 address of the neighboring IPv6 eNodeB. Indicates whether to enable the peer eNodeB to perform IP security (IPsec) negotiation with the local eNodeB through a security gateway (SeGW). This parameter is valid only when SERVIP4IPSECFL AG is set to NO ENABLE. If this parameter is set to DISABLE, the peer eNodeB directly negotiates with the local eNodeB. If this parameter is set to ENABLE, the peer eNodeB negotiates with the local eNodeB through the SeGW.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the local IPv6 address used by the neighboring IPv6 eNodeB in IPv6 IKE negotiation with the local eNodeB. The value of this NO parameter is the same as the value of the SERVIKEIP parameter in the X2ServIP6 MO configured on the neighboring IPv6 eNodeB. Indicates the mobile country code (MCC) of the neighboring NO IPv6 eNodeB. An MCC consists of three digits. Indicates the mobile network code (MNC) of the neighboring IPv6 NO eNodeB. An MNC consists of two or three digits. Indicates the ID of the peer eNodeB. Indicates the description of X2eNodeB6. Indicates the ID of the operator that owns the neighboring IPv6 eNodeB, by which the local eNodeB identifies the neighboring IPv6 eNodeB.

NO

No

LOFD-002004 / TDLOFD-002004 LOFD-003009 / TDLOFD-003009

NO

No

LOFD-002004 / TDLOFD-002004

NO

No

LOFD-002004 / TDLOFD-002004

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004 LOFD-002004

NO

NO

No

NO

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the compliance protocol release of the NO neighboring eNodeB.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-002004 / TDLOFD-002004

Indicates the name YES of the CA.

YES

No

LOFD-003010 / TDLOFD-003010

Indicates the URL of the CA. The URL can be either an HTTP or HTTPS URL. The IP address in the URL NO must be a valid IP address. The default port number is 80 for HTTP or 443 for HTTPS. Indicates the signature algorithm for message of CMP. The signature algorithm can be NO Secure Hash Algorithm 1 (SHA1) or Hash Algorithm 256 (SHA256). Indicates the common name of the certificate request file, which can be the electronic serial NO number (ESN), media access control (MAC) address, or IP address of a board. Indicates the additional information about a certificate common name. The information will be added behind the value of the COMMNAME NO parameter to compose a complete common name for a certificate request file. The default value is .huawei.com.

YES

No

LOFD-003010 / TDLOFD-003010

NO

No

None

NO

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the country where a BS NO is located.

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the organization that owns a BS.

NO

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the organization unit that owns a BS.

NO

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the state or province where a NO BS is located.

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the location of a BS.

NO

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the usage for a key, including KEY_AGREEMENT (key negotiation), DATA_ENCIPHER MENT (data encryption), KEY_ENCIPHERM NO ENT (key encryption), and DIGITAL_SIGNATU RE (digital signature). This parameter can be set to one or multiple values. Indicates the signature algorithm for a certificate request file. The signature algorithm can be Secure NO Hash Algorithm 1 (SHA1), MessageDigest Algorithm 5 (MD5) or Hash Algorithm 256 (SHA256). Indicates the length of a key, which can NO be 1024 bits or 2048 bits.

NO

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the local name of a BS.

NO

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the local NO IP address of a BS.

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the file name of a device certificate. The file name cannot include any of the following characters: backslashes (\), YES slashes (/), colons (:), asterisks (*), question marks (?), double quotation marks ("), left angle brackets (<), right angle brackets (>), and bars (|).

YES

No

LOFD-003010 / TDLOFD-003010

Indicates the serial number of a device certificate. Indicates the common name of a device certificate. Indicates the issuer of a device certificate. Indicates the expiration date of a device certificate. Indicates the date when a device certificate begins to take effect. Indicates the application type of activated device certificate. There are two types: IKE and SSL.

NO

NO

Yes

LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

YES

YES

No

LOFD-003010 / TDLOFD-003010

Indicates the file name of an activated device certificate. The file name cannot include any of the following characters: backslashes (\), NO slashes (/), colons (:), asterisks (*), question marks (?), double quotation marks ("), left angle brackets (<), right angle brackets (>), and bars (|). Indicates the issuer of an activated NO device certificate. Indicates the common name of NO an activated device certificate. Indicates the serial number of an activated device certificate. NO

YES

No

LOFD-003010 / TDLOFD-003010

NO

Yes

LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010

NO

Yes

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the expiration date of NO an activated device certificate. Indicates the IKE name of the peer device, which is used in IKE negotiation with the local end to test an activated device certificate. This NO parameter is used only in the TST APPCERT command in the current version and will be removed in later versions. Indicates the date when an activated device certificate begins to take effect.

NO

Yes

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

NO

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the loading status of an NO activated device certificate. Indicates the certificate NO application type supported by a BS. Indicates the name of the crosscertificate. The file name cannot include any of the following characters: backslashes (\), YES slashes (/), colons (:), asterisks (*), question marks (?), double quotation marks ("), left angle brackets (<), right angle brackets (>), and bars (|). Indicates the serial number of the cross- NO certificate. Indicates the common name of NO the cross-certificate. Indicates the issuer of the crossNO certificate. Indicates the expiration date of NO the cross-certificate.

NO

Yes

LOFD-003010 / TDLOFD-003010

NO

Yes

LOFD-003010 / TDLOFD-003010

YES

No

LOFD-003010 / TDLOFD-003010

NO

Yes

LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010

NO

Yes

NO

Yes

NO

Yes

Indicates the loading status of the NO cross-certificate.

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the date when the crossNO certificate begins to take effect.

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the file name of the trusted certificate. The file name cannot include any of the following characters: backslashes (\), YES slashes (/), colons (:), asterisks (*), question marks (?), double quotation marks ("), left angle brackets (<), right angle brackets (>), and bars (|). Indicates the serial number of the trusted certificate. Indicates the common name of the trusted certificate. Indicates the issuer of the trusted certificate. Indicates the expiration date of the trusted certificate.

YES

No

LOFD-003010 / TDLOFD-003010

NO

NO

Yes

LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

Indicates the loading status of the NO trusted certificate.

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the date when the trusted NO certificate begins to take effect.

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the file name of a CRL. The file name cannot include any of the following characters: backslashes (\), slashes (/), colons YES (:), asterisks (*), question marks (?), double quotation marks ("), left angle brackets (<), right angle brackets (>), and bars (|).

YES

No

LOFD-003010 / TDLOFD-003010

Indicates the loading status of a CRL.

NO

NO

Yes

LOFD-003010 / TDLOFD-003010

Indicates the issuer NO of a CRL. Indicates the next update time of the NO CRL. Indicates the current update time NO of the CRL.

NO NO

Yes Yes

LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010 LOFD-003010 / TDLOFD-003010

NO

Yes

Indicates the IP address of an FTP server or LDAP server.

NO

YES

No

LOFD-003010 / TDLOFD-003010

Indicates the user name used to log in NO to an FTP server or LDAP server. Indicates the password used to log in to an FTP server or LDAP server.

NO

No

LOFD-003010 / TDLOFD-003010

NO

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the port number of an LDAP NO server.

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the file name of a CRL. The file name cannot include any of the following characters: backslashes (\), slashes (/), colons NO (:), asterisks (*), question marks (?), double quotation marks ("), left angle brackets (<), right angle brackets (>), and bars (|). Indicates whether to update the CRL at the next update time specified in the CRL that is obtained during the latest update. If this parameter is set to ENABLE, the BS automatically updates the CRL NO when the next update time specified in the CRL arrives. If this parameter is set to DISABLE, the BS automatically updates the CRL based on the configured updating period. Indicates the interval at which the BS automatically NO obtains the CRL from the FTP server or LDAP server. Indicates the ID of the task for periodically obtaining the CRL.

YES

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

YES

YES

No

LOFD-003010 / TDLOFD-003010

Indicates the method using which NO the BS periodically obtains a CRL.

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the name of a node found in NO an LDAP server.

NO

No

LOFD-003010 / TDLOFD-003010

Indicates whether a task of certificate NO validity checking is started. Indicates the interval between certificate validity checking tasks. NO

NO

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the threshold for reporting a certificate expiration alarm. If a BS detects that the interval between its current time and the NO expiration date of an activated device certificate is shorter than the threshold, a certificate expiration alarm is reported. Indicates the method for updating a certificate that has expired or is about to expire. There are two methods: proxy and CMP. If the proxy method is used, the BS uses NO the M2000 as the proxy to update the certificate from the Certificate Authority (CA). If the CMP method is used, the BS directly updates the certificate from the CA.

NO

No

LOFD-003010 / TDLOFD-003010

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the policy type. There are three policies to use CRLs. The value NOVERIFY indicates that the BS does not perform CRL-based certificate checks. The value ALARM indicates that the BS performs CRLbased certificate checks on the peer device and reports an alarm if the NO certificate is found in the CRL. The value DISCONNECT indicates that the BS performs CRLbased certificate checks on the peer device and cuts off the communication with the peer device and reports an alarm if the certificate is found in the CRL. Indicates the ID of the Access Control List (ACL) to which the access control rule belongs. ACL ID in the range from 3000 to 3999 identifies high-level rules based on the YES layer 3 and layer 4 information. ACL ID in the range from 4000 to 4999 identifies access control rules based on the MAC layer information. Indicates the brief description of the ACL.

NO

No

LOFD-003010 / TDLOFD-003010

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

NO

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the ID of the IPv6 Access Control List (ACL) to which the IPv6 access control rule belongs. Indicates the brief description of an IPv6 ACL.

YES

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401 LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401 LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401 LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

NO

YES

No

Indicates the ID of the Access Control List (ACL) to which YES the ACL rule belongs. Indicates the ID of the ACL rule. YES

YES

No

YES

No

Indicates the action taken on the data that matches the ACL rule. When the ACL to which the ACL rule belongs is referenced by a packet filter, the BS accepts or transmits the data that matches the rule if this parameter is set to PERMIT, and rejects the data if this parameter is set NO to DENY. When the ACL is referenced by an IPSec policy, the BS encrypts or decrypts the data that matches the rule if this parameter is set to PERMIT, and does not perform any encryption or decryption on the data if this parameter is set to DENY.

NO

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the protocol type of the NO data to which the ACL rule is applied. Indicates the source IP address of data to which the ACL rule is applied. To add an ACL rule NO that is applicable to data of all source IP addresses, set this parameter to 0.0.0.0. Indicates the wildcard of the source IP address. The wildcard is used to determine which bits can be neglected when IP NO address matching is being performed. Generally, it can be considered as the inverse of the corresponding subnet mask.

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates whether to check the source port number of each NO data stream before applying the ACL rule.

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the filtering condition for the source port. If this parameter is set to OP_LT, the ACL rule is applied to the data stream whose source port number is smaller than or equal to the configured port number. If this parameter is set to OP_GT, the ACL rule is applied to the data stream whose source port number NO is larger than or equal to the configured port number. If this parameter is set to OP_EQ, the ACL rule is applied to the data stream whose source port number is equal to the configured port number. If this parameter is set to OP_NEQ, the ACL rule is applied to the data stream whose source port number Indicates the source port number used when SMPT is set to YES. If SOP is set to OP_RANGE, this parameter indicates the NO smallest source port number. If SOP is not set to OP_RANGE, this parameter indicates a specific source port number.

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the source port number used when SMPT is set to YES. If SOP is set to OP_RANGE, this parameter NO indicates the largest source port number. This parameter is valid only when SOP is set to OP_RANGE. Indicates the destination IP address of data to which the ACL rule is applied. To add an ACL rule that is NO applicable to data of all destination IP addresses, set this parameter to 0.0.0.0. Indicates the wildcard of the destination IP address. The wildcard is used to determine which bits can be neglected when IP NO address matching is being performed. Generally, it can be considered as the inverse of the corresponding subnet mask. Indicates whether to check the destination port number of each NO data stream before applying the ACL rule.

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the filtering condition for the destination port. This parameter is valid only when DMPT is set to YES. If this parameter is set to OP_LT, the ACL rule is applied to the data stream whose destination port number is smaller than or equal to the configured port number. If this parameter is set to NO OP_GT, the ACL rule is applied to the data stream whose destination port number is larger than or equal to the configured port number. If this parameter is set to OP_EQ, the ACL rule is applied to the data stream whose destination port number is equal to the configured port number. If this parameter is set to Indicates the destination port number used when DMPT is set to YES. If DOP is set to OP_RANGE, this parameter indicates the smallest NO destination port number. If DOP is not set to OP_RANGE, this parameter indicates a specific destination port number.

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the destination port number used when DMPT is set to YES. If DOP is set to OP_RANGE, this parameter indicates NO the largest destination port number. This parameter is valid only when DOP is set to OP_RANGE. Indicates whether to check the DSCP of each data stream NO before applying the ACL rule. Indicates the Differentiated Services Code Point (DSCP).

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

NO

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401 LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

NO

YES

No

Indicates whether to match the fragment message. The ACL rules for matching fragment messages NO apply to only packet filtering and does not apply to the IPSec function.

NO

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the filter criteria for VLAN IDs. This parameter is valid only when ACLID ranges from 4000 to 4999. When this parameter is set to OP_EQ, only the VLAN ID specified NO by VLANID1 is a valid one. When this parameter is set to OP_RANGE, all the VLAN IDs within the range of VLANID1 to VLANID2 are valid ones. Indicates the ID of a VLAN to which service data belongs. When Source Port Operate is set to OP_EQ, this parameter specifies the ID of the NO matching VLAN. When Source Port Operate is set to OP_RANGE, this parameter specifies the minimum ID of the matching VLANs. Indicates the ID of a VLAN to which service data belongs. When Source Port Operate is set to OP_RANGE, this parameter specifies NO the maximum ID of the matching VLANs. This parameter is valid only when Source Port Operate is set to OP_RANGE.

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

YES

No

LOFD-003009 / TDLOFD-003009 LOFD-00301401 / TDLOFD-00301401

Indicates the ID of the IPv6 Access Control List (ACL) to which the IPv6 access control rule belongs. Indicates the ID of the IPv6 ACL rule.

YES

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401 LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

YES

No

Indicates the action taken on the data that matches the IPv6 ACL rule. When the IPv6 ACL is referenced by an IPv6 IPSec policy, the BS encrypts or decrypts the data that matches the NO rule if this parameter is set to PERMIT, and does not perform any encryption or decryption on the data if this parameter is set to DENY. Indicates the protocol type of the data to which the NO IPv6 ACL rule is applied. Indicates the source IPv6 address of NO data to which the IPv6 ACL rule is applied. Indicates the prefix length of the source IPv6 address. The prefix length is used to determine which NO bits must be compared for matching when IPv6 address matching is being performed.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401 LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

Indicates whether to check the source port number of each NO data stream before applying the ACL rule. Indicates the filter criteria for the source port. If this parameter is set to OP_LT, the ACL rule is applied to the data stream whose source port number is smaller than or equal to the configured port number. If this parameter is set to OP_GT, the ACL rule is applied to the data stream whose source port number NO is larger than or equal to the configured port number. If this parameter is set to OP_EQ, the ACL rule is applied to the data stream whose source port number is equal to the configured port number. If this parameter is set to OP_NEQ, the ACL rule is applied to the data stream whose source port number Indicates the source port number used when SMPT is set to YES. If SOP is set to OP_RANGE, this parameter indicates the NO smallest source port number. If SOP is not set to OP_RANGE, this parameter indicates a specific source port number.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

Indicates the source port number used when SMPT is set to YES. If SOP is set to OP_RANGE, this parameter NO indicates the largest source port number. This parameter is valid only when SOP is set to OP_RANGE. Indicates the destination IPv6 address of data to NO which the IPv6 ACL rule is applied. Indicates the prefix length of the destination IPv6 address. The prefix length is used to determine which NO bits must be compared for matching when IPv6 address matching is being performed. Indicates whether to check the destination port number of each NO data stream before applying the ACL rule.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

Indicates the filter criteria for the destination port. This parameter is valid only when DMPT is set to YES. If this parameter is set to OP_LT, the ACL rule is applied to the data stream whose destination port number is smaller than or equal to the configured port number. If this parameter is set to NO OP_GT, the ACL rule is applied to the data stream whose destination port number is larger than or equal to the configured port number. If this parameter is set to OP_EQ, the ACL rule is applied to the data stream whose destination port number is equal to the configured port number. If this parameter is set to Indicates the destination port number used when DMPT is set to YES. If DOP is set to OP_RANGE, this parameter indicates the smallest NO destination port number. If DOP is not set to OP_RANGE, this parameter indicates a specific destination port number.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

Indicates the destination port number used when DMPT is set to YES. If DOP is set to OP_RANGE, this parameter indicates NO the largest destination port number. This parameter is valid only when DOP is set to OP_RANGE. Indicates whether to check the DSCP of each data stream NO before applying the IPv6 ACL rule. Indicates the DSCP that complies with NO an IPv6 ACL rule.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401 LBFD-003006 / TDLBFD-003006 LOFD-00301401 / TDLOFD-00301401

YES

No

Indicates the cabinet No. to which YES a BFD session belongs.

NO

No

LOFD-003007 / TDLOFD-003007

Indicates the subrack No. to which a BFD session belongs.

YES

NO

No

LOFD-003007 / TDLOFD-003007

Indicates the slot No. to which a BFD YES session belongs.

YES

No

LOFD-003007 / TDLOFD-003007

Indicates the ID of a BFD session. The session ID plus 1 is the local discriminator of the BFD session. The YES local discriminator must be consistent with the configuration at the peer side.

YES

No

LOFD-003007 / TDLOFD-003007

Indicates the source IP address of the BFD session. The source IP address of a BFD session must be a device IP address (for example, the IP address of an Ethernet port) of a specified board or a logical IP address (for example, the IP address of the NO loopback port), but cannot be set to the IP address of a remote maintenance channel or a negotiated IP address. Note that a BFD session cannot be configured as a single-hope session if its source IP address is a logical IP address.

YES

No

LOFD-003007 / TDLOFD-003007

Indicates the destination IP address of a BFD session. The destination IP address must be a valid IP address, and cannot be set to 0.0.0.0 or any existing IP addresses in the system. If Virtual NO Router Redundancy Protocol (VRRP) is used in the network, two BFD sessions must be configured with the destination IP addresses set to the active and standby physical IP addresses of the virtual router, respectively.

YES

No

LOFD-003007 / TDLOFD-003007

Indicates the hop type of the BFD session. The singlehop BFD session is used to perform point-to-point detection at the data link layer, and often used in layer 2 networking NO scenarios. The multihop BFD session is used to perform endto-end connectivity checks at the transport layer, and often used in layer 3 networking scenarios. Indicates the minimum interval at which the BFD NO session transmits control packets. Indicates the minimum interval at which the BFD NO session receives control packets. Indicates the detection multiplier of a BFD session.

YES

No

LOFD-003007 / TDLOFD-003007

NO

No

LOFD-003007 / TDLOFD-003007

NO

No

LOFD-003007 / TDLOFD-003007

NO

NO

No

LOFD-003007 / TDLOFD-003007

Indicates the type of the BFD session. If this parameter is set to MAINTENANCE, this BFD session is used only for continuity check (CC). If this parameter is set to RELIABILITY, the BFD session is NO used to trigger route interlock. Route interlock enables the standby route to take over once the active route becomes faulty, and therefore prevents service interruption caused by route failures. Indicates the Differentiated Services Code Point (DSCP). The priority has a positive correlation with the value of this parameter.

NO

No

LOFD-003007 / TDLOFD-003007

NO

NO

No

LOFD-003007 / TDLOFD-003007

Indicates whether to delete the historical statistics. If this parameter is set to YES, the historical statistics are NO deleted and a new round of statistics collecting starts upon completion of the query. Indicates the state of a BFD session. Indicates the effective detection mode through negotiation.

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

NO

Yes

LOFD-003007 / TDLOFD-003007

Indicates the effective minimum NO TX interval through negotiation. Indicates the effective minimum NO RX interval through negotiation. Indicates the detection time when NO the negotiation takes effect. Indicates the local discriminator of the BFD session. The value of this NO parameter is equal to the session number plus 1. Indicates the peer descriminator of a NO BFD session. Indicates the number of NO transmitted packets of a BFD session. Indicates the number of NO messages received by the BFD session. Indicates the up-todown number of a NO BFD session.

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

Yes

LOFD-003007 / TDLOFD-003007 LOFD-003007 / TDLOFD-003007

NO

Yes

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

Yes

LOFD-003007 / TDLOFD-003007

Indicates the diagnostic field of the BFD session, NO that is, the cause of the latest failure.

NO

Yes

LOFD-003007 / TDLOFD-003007

Indicates the interface index of a BFD session. For NO the BFD session in multi-hop mode, the interface index is 0. Indicates the protocol version of a NO BFD session.

NO

Yes

LOFD-003007 / TDLOFD-003007

NO

No

LOFD-003007 / TDLOFD-003007

Indicates the deployment position of a digital certificate. If this parameter is set to DEFAULT, the certificate is configured on the main control board. If this parameter is NO set to SPECIFIC, the certificate is configured on the board in the specified slot. If this parameter is set to NULL, no certificate is configured on the BS. Indicates the number of the cabinet where a board is located. Indicates the number of the subrack where a board is located. Indicates the number of the slot where a board is located.

NO

No

LOFD-003010 / TDLOFD-003010

NO

NO

No

LOFD-003010 / TDLOFD-003010

NO

NO

No

LOFD-003010 / TDLOFD-003010

NO

NO

No

LOFD-003010 / TDLOFD-003010

Indicates the name of the MD to which YES the RMEP belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the name of the MA to which YES the RMEP belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the RMEP YES ID. Indicates the IP address at the Ethernet port or Ethernet trunk corresponding to the RMEP. The IP address bound to the remote MEP cannot be the same as the existing local IP address or any IP address of an effective physical or loopback port. The bound IP address cannot be the same as the local IP YES address dynamically negotiated on the PPP/MLPPP link. When the IP address is bound, the existing IP address of the system may conflict with the IP address to be configured, run the LST/DSP (DEVIP, OMCH, PPPLNK, LOCALIP, MPGRP, or IPRT) command to query the IP Indicates the name of the MD to which YES the MA belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

YES

No

LOFD-00300402 / TDLOFD-00300402

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the name YES of the MA.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates cabinet number of the board NO to which the MA belongs. Indicates subrack number of the board NO to which the MA belongs. Indicates slot number of the board NO to which the MA belongs. Indicates whether the MA is NO associated with the VLAN. Indicates the ID of the VLAN with which the MA is associated.

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

No

LOFD-00300402 / TDLOFD-00300402

YES

No

LOFD-00300402 / TDLOFD-00300402

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

NO

No

LOFD-00300402 / TDLOFD-00300402

Indicates the priority of the VLAN with NO which the MA is associated. Indicates the interval at which the CFM MA transmits NO continuity check messages (CCMs). Indicates the number of local MEPs in an MA. Indicates the number of RMEPs in an MA. NO

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402

NO

NO

Yes

Indicates the list of local MEPs in an MA. Indicates the list of RMEPs in an MA.

NO NO

NO NO

Yes Yes

LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402

Indicates the name YES of the CFM MD.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the level of the CFM MD.

NO

NO

No

LOFD-00300402 / TDLOFD-00300402

Indicates the number of MAs in a NO CFMMD. Indicates the list of all MAs in a NO CFMMD. Indicates the name of the MD to which YES the MEP belongs.

NO

Yes

LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402

NO

Yes

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the name of the MA to which YES the MEP belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the MEP ID.

YES

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates cabinet number of the board NO to which the MEP belongs. Indicates subrack number of the board NO to which the MEP belongs. Indicates slot number of the board NO to which the MEP belongs.

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

No

LOFD-00300402 / TDLOFD-00300402

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the type of subboard on the NO board where the MEP is located.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the port type of MEP.

NO

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the port NO number of the MEP.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates whether to enable the NO continuity check (CC) of the CFM. Indicates the ID of a VLAN of the MA to NO which the MEP belongs. Indicates the ID of a VLAN of the MA to NO which the MEP belongs. Indicates the priority of a VLAN of the NO MA to which the MEP belongs. Indicates the number of transmitted NO Connectivity Check (CC) packets.

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

Indicates the number of received NO Connectivity Check (CC) packets. Indicates the number of transmitted loopback packets. Indicates the number of received loopback packets. Indicates the number of transmitted traced over packets. Indicates the number of received traced over packets. Indicates the number of transmitted packets CFM packets. NO

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

Indicates the number of NO transmitted packets CFM packets. Indicates the number of transmitted packets NO CFM packets discarded. Indicates the number of received NO packets CFM packets discarded.

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

Indicates the name of the MD to which YES the RMEP belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the name of the MA to which YES the RMEP belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

Indicates the RMEP YES ID. Indicates the MAC address of the RMEP. It must be a valid unicast address in the format of XXXXXXXX-XXXX. The MAC address of the RMEP can be obtained from the MAC address field NO carried in the CCM message. If the MAC address configured by the user is different from that carried in the CCM message, the MAC address carried in the MAC message prevails. Indicates the status NO of the RMEP. Indicates the actual MAC address of the RMEP. The format NO is XXXX-XXXXXXXX. Indicates the priority of a VLAN of the NO MA to which the RMEP belongs. Indicates the ID of a VLAN of the MA to NO which the RMEP belongs.

YES

No

LOFD-00300402 / TDLOFD-00300402

NO

No

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402 LOFD-00300402 / TDLOFD-00300402

NO

Yes

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

Indicates the number of received NO CCM packets from the RMEP. Indicates the number of the IP NO addresses bound to the RMEP. Indicates the list of the IP addresses NO bound to the RMEP. Indicates the type of the commissioning YES service.

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

NO

Yes

LOFD-00300402 / TDLOFD-00300402

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the number of the YES commissioning port.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the switch used to enable or disable the commissioning port to run commissioning services. This port is physically located at the local maintenance Ethernet port. If this parameter is set to DISABLE, the commissioning port cannot run commissioning NO services. If this parameter is set to ENABLE, the commissioning port can run commissioning services. In this situation, this commissioning port receives cyber attacks, therefore special caution must be exercised during the setting of this parameter. Indicates the cabinet number of YES the board where the port is located. Indicates the subrack number of YES the board where the port is located. Indicates the slot number of the board YES where the port is located.

YES

No

LOFD-003014 / TDLOFD-003014

NO

No

None

NO

No

None

YES

No

None

Indicates the type of sub-board on the YES board where a port is located.

YES

No

None

Indicates the port type.

YES

YES

No

None

Indicates the number of a port.

YES

YES

No

None

Indicates the IP address configured YES for the port.

YES

No

None

Indicates the subnet mask of the device IP address NO configured on the port.

YES

No

None

Indicates the interface index of the device IPv6 address.

YES

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the device YES IPv6 address.

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the length of the prefix of the NO device IPv6 address.

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the status of the device IPv6 NO address.

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates the time interval during which the device IPv6 address is in the valid state.

NO

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates the time interval during which the device IPv6 address is in the preferred state. Valid states are categorized into the preferred state and the deprecated state. In the preferred state, an address can be NO freely used; in the deprecated state, the connections previously established on this address are still usable, whereas any connection newly established on this address is not usable.

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates whether to enable the DHCP NO relay switch.

NO

No

None

Indicates the IP address of the DHCP server.

YES

YES

No

LBFD-00300102 / TDLBFD-00300102 LBFD-00300103 / TDLBFD-00300103 LOFD-002004 / TDLOFD-002004

Indicates whether to enable detection of automatic establishment of the NO remote maintenance channel.

NO

No

LOFD-002004 / TDLOFD-002004

Indicates the rule for prioritizing traffic to meet service requirements. If this parameter is set to IPPRECEDENCE, the protocol stack of NO the earlier version is adopted, which firstly converts types of service (TOSs) to DSCPs and then prioritizes traffic.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of signaling. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of the high-level OM data. The priority has a positive correlation with the value of this parameter. The highNO level OM data includes the packets related to remote maintenance channel switchover and DHCP relay.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of the low-level OM data, such as the data to be uploaded or downloaded. The priority has a positive correlation NO with the value of this parameter. The low-level OM data includes the packets related to File Transfer Protocol (FTP).

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the DSCP of the IP clock packet. If the clock that follows the Precision Time Protocol (PTP) is used, the DSCP of the PTP packets NO takes effect. If the clock that follows the Huawei proprietary protocol is used, the DSCP of the protocol packet takes effect.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 1. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 1.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 1. This threshold equals the NO ratio of the bandwidth occupied by the type-1 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 1. This threshold equals the ratio of the primaryport bandwidth occupied by the type-1 data to the NO secondary-port bandwidth occupied by the type-1 data. When this threshold is exceeded, the type-1 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 2. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 2.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 2. This threshold equals the NO ratio of the bandwidth occupied by the type-2 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 2. This threshold equals the ratio of the primaryport bandwidth occupied by the type-2 data to the NO secondary-port bandwidth occupied by the type-2 data. When this threshold is exceeded, the type-2 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 3. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 3.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 3. This threshold equals the NO ratio of the bandwidth occupied by the type-3 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 3. This threshold equals the ratio of the primaryport bandwidth occupied by the type-3 data to the NO secondary-port bandwidth occupied by the type-3 data. When this threshold is exceeded, the type-3 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 4. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 4.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 4. This threshold equals the NO ratio of the bandwidth occupied by the type-4 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 4. This threshold equals the ratio of the primaryport bandwidth occupied by the type-4 data to the NO secondary-port bandwidth occupied by the type-4 data. When this threshold is exceeded, the type-4 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 5. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 5.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 5. This threshold equals the NO ratio of the bandwidth occupied by the type-5 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 5. This threshold equals the ratio of the primaryport bandwidth occupied by the type-5 data to the NO secondary-port bandwidth occupied by the type-5 data. When this threshold is exceeded, the type-5 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 6. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 6.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 6. This threshold equals the NO ratio of the bandwidth occupied by the type-6 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 6. This threshold equals the ratio of the primaryport bandwidth occupied by the type-6 data to the NO secondary-port bandwidth occupied by the type-6 data. When this threshold is exceeded, the type-6 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 7. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 7.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 7. This threshold equals the NO ratio of the bandwidth occupied by the type-7 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 7. This threshold equals the ratio of the primaryport bandwidth occupied by the type-7 data to the NO secondary-port bandwidth occupied by the type-7 data. When this threshold is exceeded, the type-7 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 8. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 8.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 8. This threshold equals the NO ratio of the bandwidth occupied by the type-8 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 8. This threshold equals the ratio of the primaryport bandwidth occupied by the type-8 data to the NO secondary-port bandwidth occupied by the type-8 data. When this threshold is exceeded, the type-8 data is preferentially admitted through the port with a light load.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the priority of user data type 9. The priority has a NO positive correlation with the value of this parameter.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the type of primary transport NO resource for user data type 9.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the primary port load threshold of user data type 9. This threshold equals the NO ratio of the bandwidth occupied by the type-9 data to the total port bandwidth. Indicates the threshold of the primary-tosecondary port load ratio of user data type 9. This threshold equals the ratio of the primaryport bandwidth occupied by the type-9 data to the NO secondary-port bandwidth occupied by the type-9 data. When this threshold is exceeded, the type-9 data is preferentially admitted through the port with a light load. This parameter indicates whether to limit S1 interface downlink rate measured in bit per second (bps) in case of LBBP CPU overload. When S1 interface downlink traffic volume NO exceeds LBBP process ability, CPU in LBBP will overload and it will lead to degradation of air interface. This switch can be turned on to limit S1 interface downlink rate.

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

LBFD-00300201 / TDLBFD-00300201

NO

No

None

This parameter indicates whether to limit S1 interface downlink rate measured in packet per second (pps) in case of LBBP CPU overload. When S1 interface downlink traffic volume NO exceeds LBBP process ability, CPU in LBBP will overload and it will lead to degradation of air interface. This switch can be turned on to limit S1 interface downlink rate. Indicates the number of the cabinet that provides the port on YES which IEEE 802.1X authentication is configured. Indicates the number of the subrack that provides the port on YES which IEEE 802.1X authentication is configured. Indicates the number of the slot that provides the port on which IEEE YES 802.1X authentication is configured. Indicates the type of sub-board that provides the port on YES which IEEE 802.1X authentication is configured.

NO

No

None

NO

No

None

NO

No

None

YES

No

None

YES

No

None

Indicates the number of the port on which IEEE 802.1X authentication is configured.

YES

YES

No

LOFD-003015 / TDLOFD-003015

Indicates the IEEE 802.1X authentication method. Currently, only Extensible Authentication Protocol Transport NO Layer Security (EAPTLS), a unidirectional authentication method, is supported. Indicates the number of abnormal packets received NO during the 802.1X authentication. Indicates the number of IEEE 802.1X authentication failures.

NO

No

LOFD-003015 / TDLOFD-003015

NO

Yes

LOFD-003015 / TDLOFD-003015

NO

NO

Yes

LOFD-003015 / TDLOFD-003015

Indicates the cause of the latest IEEE 802.1X authentication failure or the latest unauthentication where the BS does not initiate the NO authentication. The value of this parameter is deleted after a successful IEEE 802.1X authentication.

NO

Yes

LOFD-003015 / TDLOFD-003015

Indicates the number of received Extensible NO Authentication Protocol (EAP) messages. Indicates the status of IEEE 802.1X authentication. Possible states are as follows: UNAUTHENTICAT ED(Unauthenticated ), AUTHENTICATING (Authenticating), NO AUTHENTIC_SUC CEED(Authenticate Succeed), AUTHENTIC_FAIL( Authenticate Fail), and DHCP_AUTHENTI CATING(DHCP Activation Authenticating). Indicates the number of transmitted Extensible Authentication Protocol (EAP) messages. Indicates the number of successful IEEE 802.1X authentications.

NO

Yes

LOFD-003015 / TDLOFD-003015

NO

Yes

LOFD-003015 / TDLOFD-003015

NO

NO

Yes

LOFD-003015 / TDLOFD-003015

NO

NO

Yes

LOFD-003015 / TDLOFD-003015

Indicates the priority of a DSCP. A larger value of this YES parameter indicates a higher priority. Indicates the priority of a VLAN. A larger value of this NO parameter indicates a higher priority. Indicates the number of the cabinet housing the YES board where an E1/T1 port is located.

YES

No

LBFD-00300201 / TDLBFD-00300201

YES

No

LBFD-003003 / TDLBFD-003003

NO

No

None

Indicates the number of the subrack housing the YES board where the E1/T1 port is located. Indicates the number of the slot housing the board where the E1/T1 port is located. Indicates the number of the E1/T1 port.

NO

No

None

YES

YES

No

None

YES

NO

No

None

Indicates the range of E1/T1 ports. Note that the E1T1 MO with this parameter NO set to ALLPORT is actually not created on the BS. Indicates the working mode of the E1/T1 port. This parameter must be NO set to the same value as that at the peer end.

NO

No

None

NO

No

None

Indicates the frame format used by the NO E1/T1 port.

YES

No

None

Indicates the line coding mode of an E1/T1 port.

NO

YES

No

None

Indicates the clock mode of the E1/T1 port. 1. If the BS extracts the line clock from the E1/T1 port, the clock mode of the E1/T1 port must be set to SLAVE. If the BS provides the line clock for the lowerlevel equipment through the E1/T1 port, the clock mode of the E1/T1 port must be set to MASTER. NO Otherwise, the line clock may fail to work properly. 2. When the E1/T1 port provides an 8K clock reference for the transmission interface board, the clock mode of the E1/T1 port must be set to SLAVE. 3. The clock modes of E1/T1 ports used by an inter-board MLPPP group cannot be all set to SLAVE.

NO

No

None

Indicates the link running status. The link running status is classified into OK, LOCAL_LOOP, REMOTE_LOOP, PAYLOAD_LOOP, NO SINGLE_CH_LOO P, PHYSICAL_LOOP, LOS, AIS, RA, LFA, LMFA, SLIP, BACKUP, and OTHERS.

NO

Yes

None

Indicates whether to perform the link test and the test type. The test types are NO classified into No Test, Offline Test, and Online Test. Indicates whether the E1/T1 port is used. Indicates the left loop time of the E1/T1 port.

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the type of sub-board on the board where the YES E1/T1 port is located.

YES

No

None

Indicates the in-use work mode of the NO E1/T1 port.

NO

Yes

None

Indicates the in-use frame format of the NO E1/T1 port.

NO

Yes

None

Indicates the in-use line coding mode of NO the E1/T1 port.

NO

Yes

None

Indicates the BER threshold.

NO

NO

No

None

Indicates the cabinet number of the board where the YES Ethernet port is located. Indicates the subrack number of the board where the YES Ethernet port is located. Indicates the slot number of the board YES where the Ethernet port is located.

NO

No

LOFD-00300401 / TDLOFD-00300401

NO

No

LOFD-00300401 / TDLOFD-00300401

YES

No

LOFD-00300401 / TDLOFD-00300401

Indicates the type of sub-board on the board where the YES Ethernet port is located.

YES

No

LOFD-00300401 / TDLOFD-00300401

Indicates the type of YES the Ethernet port.

YES

No

LOFD-00300401 / TDLOFD-00300401

Indicates the number of the Ethernet port.

YES

YES

No

LOFD-00300401 / TDLOFD-00300401

Indicates the work mode of the IEEE802.3ah Ethernet OAM. If this parameter is set to ACTIVE, the local end initiates the IEEE802.3ah Ethernet OAM negotiation. NO If this parameter is set to PASSIVE, the local end does not initiate the negotiation; instead, the local end waits for receiving negotiation packets from the peer end.

NO

No

LOFD-00300401 / TDLOFD-00300401

Indicates the internal at which a Protocol Data Unit (PDU) is transmitted for fault detection. A NO shorter interval indicates that Ethernet link faults can be detected more quickly. Indicates the size of the Protocol Data NO Unit (PDU). Indicates whether remote loopback can be enabled at the port where 3AH detection is activated. If remote loopback is enabled, the OAM 3AH loopback is allowed. For details, see the STR NO ETHOAMLOOPTST command. During the loopback, only 3AH packets rather than other types of packet can be transmitted. If remote loopback is disabled, the local end cannot initiate the loopback. Indicates whether to enable indication of NO link faults. Indicates the duration of the NO erroneous frame event.

NO

No

LOFD-00300401 / TDLOFD-00300401

NO

No

LOFD-00300401 / TDLOFD-00300401

NO

No

LOFD-00300401 / TDLOFD-00300401

NO

No

LOFD-00300401 / TDLOFD-00300401 LOFD-00300401 / TDLOFD-00300401

NO

No

Indicates the threshold for the erroneous frame event. If the number of erroneous frames within a second NO exceeds the threshold, an erroneous frame event occurs. This event is checked every other second. Indicates the duration of the Error Frame Seconds Summary Event. An error frame second NO refers to a second within which one or more error frames are detected. Indicates the threshold for the accumulated erroneous frame event. If the length of time that erroneous frames occupy within a sampling period specified through the ERRFRMSCDEVT PRD parameter exceeds the threshold, an accumulated erroneous frame event occurs.

NO

No

LOFD-00300401 / TDLOFD-00300401

NO

No

LOFD-00300401 / TDLOFD-00300401

NO

NO

No

LOFD-00300401 / TDLOFD-00300401

Indicates the Finite State Machine NO (FSM) status of an Ethernet OAM 3AH.

NO

Yes

LOFD-00300401 / TDLOFD-00300401

Indicates the number of discarded OAM PDUs on the RX channel. Indicates the number of received Event OAM PDUs. Indicates the number of received Fault OAM PDUs. Indicates the number of Info OAM PDUs received on a port.

NO

NO

Yes

LOFD-00300401 / TDLOFD-00300401 LOFD-00300401 / TDLOFD-00300401 LOFD-00300401 / TDLOFD-00300401 LOFD-00300401 / TDLOFD-00300401

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

Indicates the number of received NO Loopback Control OAM PDUs. Indicates the total number of received OAM PDUs, including the information OAM NO PDUs, event OAM PDUs, loopback OAM PDUs, and discarded OAM PDUs. Indicates the number of NO discarded OAM PDUs on the TX channel.

NO

Yes

LOFD-00300401 / TDLOFD-00300401

NO

Yes

LOFD-00300401 / TDLOFD-00300401

NO

Yes

LOFD-00300401 / TDLOFD-00300401

Indicates the number of transmitted Event OAM PDUs. The Event OAM PDUs are used to notify the peer end of a link event. Indicates the number of transmitted Fault OAM PDUs. The Fault OAM PDUs are used to notify the peer end of a link failure.

NO

NO

Yes

LOFD-00300401 / TDLOFD-00300401

NO

NO

Yes

LOFD-00300401 / TDLOFD-00300401

Indicates the number of transmitted Info OAM Protocol Data NO Units (PDUs). The Info OAM PDUs are used to finish the search process. Indicates the number of transmitted loopback OAM PDUs. The loopback OAM PDUs are used for remote loopback control.

NO

Yes

LOFD-00300401 / TDLOFD-00300401

NO

NO

Yes

LOFD-00300401 / TDLOFD-00300401

Indicates the total number of transmitted OAM PDUs, including the information OAM NO PDUs, event OAM PDUs, loopback OAM PDUs, and discarded OAM PDUs. Indicates the cabinet number of the board where the YES Ethernet port is located.

NO

Yes

LOFD-00300401 / TDLOFD-00300401

NO

No

None

Indicates the subrack number of the board where the YES Ethernet port is located.

NO

No

None

Indicates the slot number of the board YES where the Ethernet port is located.

YES

No

None

Indicates the type of sub-board on the board where the YES Ethernet port is located.

YES

No

None

Indicates the number of the Ethernet port.

YES

YES

No

None

Indicates whether an Ethernet port is an electrical port or optical port. When the system starts, the system binds an Ethernet port to an optical port NO preferentially if the default value of the port attribute is AUTO. If the BS does not support cascading, the port attribute is set to AUTO. Indicates the maximum transmission unit (MTU) for the Ethernet port. It specifies the maximum size of the IP packet (including the IP header) that can flow through the Ethernet port. A value equal to or larger than 576 is recommended, because broadcast packets, such as NO the DHCP packet, may experience reception or transmission failures if the MTU is smaller than 576. After the Ethernet port is added to an Ethernet trunk, this parameter stops taking effect and the actual MTU for the Ethernet port depends on the setting of the same parameter in the Ethernet trunk.

YES

No

None

NO

No

None

Indicates the speed mode of the Ethernet port. This parameter must be set to the same value as that of the peer port. GE electrical ports support 1000 Mbit/s only when working in auto-negotiation mode. If SPEED of NO a GE optical port is set to AUTO, the port works at 1000 Mbit/s in autonegotiation mode. If SPEED of a GE optical port is set to 1000M, the port works at 1000 Mbit/s in manual configuration mode.

NO

No

None

Indicates the duplex mode of the NO Ethernet port.

NO

No

None

Indicates whether to enable the proxy ARP function. If this function is enabled, the BS serves as an ARP proxy for the IP address of a loopback interface on the BS or a port IP address of a lower-level BS. If this function is disabled, an external device can access a loopback interface in the BS or a lower-level BS NO on the same subnet only by using a route. After the Ethernet port is added to an Ethernet trunk, this parameter stops taking effect and whether the proxy ARP function is enabled for the Ethernet port depends on the setting of the same parameter in the Ethernet trunk.

NO

No

None

Indicates whether to enable flow control on the Ethernet port. Flow control is implemented to prevent congestion. When flow control is enabled, the RX end repeatedly sends PAUSE frames to the TX end, instructing the NO TX end to lower the TX rate if congestion occurs on the RX end. Upon receiving PAUSE frames, the TX end stops sending data during a period of time to prevent congestion. For details, see IEEE 802.3ah. Indicates the generation threshold for the MAC Excessive Frame Error Rate alarm (ID: 25881). When the number NO of erroneous MAC frames exceeds this threshold, the MAC Excessive Frame Error Rate alarm is reported. Indicates the clearance threshold for the MAC Excessive Frame Error Rate alarm (ID: 25881). When the number of NO erroneous MAC frames falls below this threshold, the MAC Excessive Frame Error Rate alarm is cleared.

NO

No

None

NO

No

None

NO

No

None

Indicates the MAC address (six bytes) configured for the Ethernet port. The format is XXXXXXXX-XXXX.

NO

NO

Yes

None

Indicates the status NO of the Ethernet port.

NO

Yes

None

Indicates the loopback status of the Ethernet port.

NO

NO

Yes

None

Indicates whether the Ethernet port is in the steady state of the OAM 3AH NO loopback response. For details, see IEEE 802.3ah. Indicates whether the Ethernet OAM 3AH is enabled. Indicates the number of packets received at the Ethernet port. Indicates the number of bytes received at the Ethernet port. Indicates the number of CRC error packets received at the Ethernet port. NO

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the traffic received at the NO Ethernet port. Indicates the number of packets NO transmitted at the Ethernet port. Indicates the number of bytes NO transmitted at the Ethernet port. Indicates the traffic transmitted at the NO Ethernet port.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the number of IP addresses configured for the Ethernet port. Indicates the IP address and mask list configured for the Ethernet port.

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the negotiation mode NO configured on the Ethernet port. Indicates the actual negotiation mode of NO the Ethernet port. Indicates the speed mode of the Ethernet port. This parameter must be NO set to the same value as that of the peer port. Indicates the duplex mode of the Ethernet port. If an Ethernet electrical port is used, this parameter is valid NO when SPEED is not set to AUTO. If an Ethernet optical port is used, this parameter must be set to FULL. Indicates the negotiation mode of NO the NE connecting to the Ethernet port.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the speed mode of the NE NO connecting to the Ethernet port.

NO

Yes

None

Indicates the duplex mode of the NE NO connecting to the Ethernet port.

NO

Yes

None

Indicates the physical layer status NO of the Ethernet port. Indicates the cabinet number of the board where the YES Ethernet trunk is established. Indicates the number of the subrack housing the YES board where the Ethernet trunk is established. Indicates the number of the slot housing the board YES where the Ethernet trunk is established. Indicates the number of the Ethernet trunk.When the board is a UTRPc board, the value of this parameter YES ranges from 0 to 2. When the board is a board other than the UTRPc board, the value of this parameter ranges from 0 to 1.

NO

Yes

None

NO

No

LOFD-003008 / TDLOFD-003008

NO

No

LOFD-003008 / TDLOFD-003008

YES

No

LOFD-003008 / TDLOFD-003008

NO

No

LOFD-003008 / TDLOFD-003008

Indicates the type of Ethernet trunk. If this parameter is set to DISABLE, member ports of the Ethernet trunk must be manually configured. In this case, the configured member ports are considered as valid member ports of the Ethernet trunk. NO If this parameter is set to ENABLE, member ports of the Ethernet trunk must also be manually configured. In this case, the valid member ports of the Ethernet trunk are negotiated between the BS and the peer end according to LACP.

NO

No

LOFD-003008 / TDLOFD-003008

Indicates whether to enable the ARP proxy function on the Ethernet trunk. If this parameter is set to ENABLE, the BS performs the ARP proxy on the IP addresses of its loopback interfaces (or of the lowerlevel BS). If this parameter is set to NO DISABLE, the BS does not perform the ARP proxy on the IP addresses of its loopback interfaces (or of the lower-level BS). The external device on the same subnet needs to access the IP address through a configured route.

NO

No

LOFD-003008 / TDLOFD-003008

Indicates the type of subboard on the board where the YES Ethernet trunk is established.

YES

No

LOFD-003008 / TDLOFD-003008

Indicates the size of the Maximum Transmission Unit (MTU) in the Ethernet trunk. The recommended MTU value is above 576. NO If the value is smaller than 576, broadcast packets such as the DHCP packet fail to be received or transmitted.

NO

No

LOFD-003008 / TDLOFD-003008

Indicates the status of the Ethernet trunk. The state of the Ethernet trunk depends on the state of the member ports. If the state of NO the member ports of the existing Ethernet trunk is activated, the state of the Ethernet trunk is activated.

NO

Yes

LOFD-003008 / TDLOFD-003008

Indicates the MAC address of the Ethernet trunk. The format is XXXXXXXX-XXXX. The NO MAC address of an Ethernet port is that of the first Ethernet port added to the Ethernet trunk. Indicates the MAC address of the Ethernet trunk at the peer end. The format is XXXXXXXX-XXXX. If the Ethernet trunk type is set to ENABLE, this parameter NO specifies the MAC address of the peer end, which is negotiated between the BS and the peer end by using the LACP protocol. For details, see IEEE 802.3ad. Indicates the number of member NO ports in the Ethernet trunk. Indicates the number of the NO member port of the Ethernet trunk. Indicates the number of active NO member ports of the Ethernet trunk. Indicates the number of an active NO member port of the Ethernet trunk. Indicates the number of packets (including the NO discarded packets) received by the Ethernet trunk.

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

Indicates the number of bytes (including the discarded bytes) received by the Ethernet trunk. Indicates the number of discarded packets received by the Ethernet Indicates trunk. the

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

number of NO discarded bytes received by the Ethernet trunk. Indicates the number of packets (including the NO discarded packets) transmitted by the Ethernet trunk. Indicates the number of bytes (including the discarded bytes) transmitted by the Ethernet trunk. Indicates the number of discarded packets transmitted by the Ethernet trunk. Indicates the number of discarded bytes transmitted by the Ethernet trunk. Indicates the number of IP addresses configured for the Ethernet trunk. Indicates the IP address list of the Ethernet trunk.

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

Indicates the number of the cabinet housing the board where the YES member port of an Ethernet trunk is located.

NO

No

LOFD-003008 / TDLOFD-003008

Indicates the number of the subrack housing the board where the YES member port of an Ethernet trunk is located. Indicates the number of the slot housing the board where the member port of an Ethernet trunk is located. Indicates the number of the parent Ethernet trunk of the port.

NO

No

LOFD-003008 / TDLOFD-003008

YES

YES

No

LOFD-003008 / TDLOFD-003008

YES

NO

No

LOFD-003008 / TDLOFD-003008

Indicates the number of the member port in an Ethernet trunk.

YES

YES

No

LOFD-003008 / TDLOFD-003008

Indicates the priority of the member port in an Ethernet trunk. NO A smaller parameter value indicates a higher priority. Indicates whether the member port is the primary port of an Ethernet trunk. Each Ethernet trunk has one and only one primary port. NO The primary port must be the first port added to an Ethernet trunk and the last port removed from the Ethernet trunk.

NO

No

LOFD-003008 / TDLOFD-003008

YES

No

LOFD-003008 / TDLOFD-003008

Indicates the type of sub-board on the board where the YES member port of an Ethernet trunk is located.

YES

No

LOFD-003008 / TDLOFD-003008

Indicates the status of the member port NO in an Ethernet trunk. Indicates the MAC address of the member port when being added to an NO Ethernet trunk. The format of the MAC address is XXXXXXXX-XXXX. Indicates the period mode of transmitting the LACP Protocol Data Units (PDUs) at the local end. In long NO period mode, the time interval for periodically transmitting the LACP PDUs is large. Indicates the period mode of transmitting the NO LACP PDUs at the peer end. Indicates the number of received LACP PDUs on the NO member port of an Ethernet trunk.

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

NO

Yes

LOFD-003008 / TDLOFD-003008

Indicates the number of transmitted LACP PDUs on the member port of an Ethernet trunk.

NO

NO

Yes

LOFD-003008 / TDLOFD-003008

Indicates the number of the YES extension user data type. Indicates the ID of the transport parameter group related to the NO services corresponding to an extended QCI. Indicates the ID of the transport parameter group related to the service that YES corresponds to the extended QCI. It uniquely identifies a transport parameter group. Indicates the priority of the service data, which is identified by a DSCP value. The priority of the NO service data has a positive correlation with the DSCP value. Indicates the activity factor of the services NO corresponding to an extended QCI.

YES

No

None

YES

No

None

YES

No

None

YES

No

None

NO

No

None

Indicates the type of primary transport resource used to transmit the user date when hybrid transmission is adopted. HQ indicates that highquality transport resources are used, while LQ indicates that low-quality transport resources NO are used. When a new service requests admission and admission control is performed, one of the IP path routes with transport resources of the same quality is used as the primary transport path. Indicates the primary port load threshold of the user data in the hybrid transmission NO scenario. A larger value indicates that services are more likely to be admitted to the primary path. Indicates the primary-tosecondary port load ratio threshold of user data in the hybrid transmission NO scenario. A smaller value indicates that services are more likely to be admitted to the primary path.

YES

No

None

YES

No

None

YES

No

None

Indicates the type of the flood packet to YES be measured.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates whether to enable the protection against NO excessive flood packets.

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the threshold for starting the protection against excessive flood packets. If the DFDSW parameter is set to ENABLE, the system discards the extra packets when the RX rate of NO flood packets exceeds the threshold. It is recommended that the difference between Defend Threshold and Alarm Threshold is greater than 3% of Defend Threshold.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates whether to report an alarm when the local end NO receives excessive flood packets from the peer end.

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the threshold for the excessive flood packet alarm. If the ALMSW parameter is set to ENABLE, the system measures the RX rate of flood packets every 10 seconds. If the measured value exceeds the threshold, an excessive flood NO packet alarm is reported. The alarm is cleared if the RX rate of flood packets keeps below the threshold for five consecutive minutes. It is recommended that the difference between Defend Threshold and Alarm Threshold is greater than 3% of Defend Threshold. Indicates the number of packets discarded because the number of flood NO packets exceeds the specified threshold. Indicates the total number of received NO attack packets.

YES

No

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the switch used to control whether to allocate bandwidths to transmission resource groups on the physical port based on their scheduling weights. When RATECFGTYPE (the rate configuration type) is set to SINGLE_RATE, different values of this parameter lead NO to different bandwidth allocation methods as follows: (1) If this parameter is set to DISABLE and the sum of TX bandwidths of the associated resource groups exceeds the bandwidth of the physical port, each resource group is allocated a bandwidth that is directly proportional to its configured TX

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the rate configuration mode of transmission resource groups in the BS, which can be set to SINGLE_RATE or DUAL_RATE. The dual rate configuration refers to the hybrid of the peak information rate (PIR) and committed information rate (CIR). If this parameter is set to NO SINGLE_RATE, the transmission resource group performs traffic shaping based on its transmit bandwidth. If this parameter is set to DUAL_RATE, the transmission resource group performs traffic shaping based on PIR and the transmission admission algorithm ensures that the Indicates the interval between the time single-hop BFD detects that the state of the active route NO changes from DOWN to UP and the time the active route becomes available. Indicates the IKE local name.

NO

No

LOFD-003011 / TDLOFD-003011

NO

No

LOFD-003011 / TDLOFD-003011

NO

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the time interval for sending the keepalive packets. If the NO parameter is set to 0, keepalive packets are not sent. Indicates the timeout duration for waiting for the keepalive packets. NO If this parameter is set to 0, keepalive packets are not sent. Indicates the DSCP for IKE negotiation NO packets. Indicates the cabinet number of NO the IKE local board. Indicates the subrack number of NO the IKE local board. Indicates the slot number of the IKE NO local board.

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009 LOFD-003009 / TDLOFD-003009 LOFD-003009 / TDLOFD-003009 LOFD-003009 / TDLOFD-003009

NO

Yes

NO

Yes

NO

Yes

Indicates the name YES of the IKE peer.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the ID of the IKE proposal in NO use.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the IKE protocol version.

NO

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the IKE exchange mode. In main mode, keys are exchanged independently from identity authentications. This protects NO identity information and hence enhances security. The aggressive mode does not have identity authentication protection. Indicates the type of the identification payload that the local end transmits. The authentication NO can be performed based on IP or fully qualified domain name (FQDN). Indicates the IP address of the peer end. When the encapsulation mode of the IPSec proposal is the transmission mode, the IP address of NO the IKE peer must be the same as the destination IP address of the ACL rule. If they are different, encoded packets will fail to be decoded.

NO

No

LOFD-003009 / TDLOFD-003009

YES

No

LOFD-003009 / TDLOFD-003009

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the name NO of the peer end.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the preshared key. The two negotiation ends must be configured with the same authenticator. This parameter takes effect only when NO Authentication Method in the corresponding IKEPROPOSAL is set to PRE_SHARED_KE Y. Indicates whether to enable the dead NO peer detection (DPD) function. Indicates the DPD idle time. If the local end does not receive encrypted packets for a time defined by this parameter, it sends a DPD packet to NO perform dead peer detection. The interval for sending a DPD packet slightly varies in various network environments. Indicates the interval at which DPD detection frames are sent. The interval at which DPD detection frames NO are sent may slightly vary in various network environments such as network congestion, delay, and jitter. Indicates the number of retransmission NO attempts after a DPD detection fails.

YES

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the IP address of the local end, which is used in IKE negotiation. This IP address can be set to 0.0.0.0 or a configured interface IP address at the local end. If this parameter is set to 0.0.0.0, the BS automatically uses the interface IP address to negotiate with the peer. If multiple IP addresses are NO configured at the port, it is recommended that you specify one IP address for the negotiation. If the local BS uses the digital certificate and IP address for authentication in the negotiation, ensure that the IP address in the certificate is the same as the local IP address of the BS. Indicates the cabinet number of NO the IKE peer board. Indicates the subrack number of NO the IKE peer board. Indicates the slot number of the IKE NO peer board.

NO

No

LOFD-003009 / TDLOFD-003009

NO

Yes

LOFD-003009 / TDLOFD-003009 LOFD-003009 / TDLOFD-003009 LOFD-003009 / TDLOFD-003009

NO

Yes

NO

Yes

Indicates the name of the IPv6 IKE YES peer.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the ID of the security proposal used by an NO IPv6 IKE negotiation.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the protocol version of the IPv6 IKE.

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the IPv6 IKE negotiation mode. In main mode, keys are exchanged independently from identity authentications. This protects identity information and hence NO enhances security. The aggressive mode does not have identity authentication protection. This mode, however, meets the requirements in specific network environments. Indicates the type of the identification payload that the local end transmits in IPv6 networks. The authentication NO can be performed based on IPv6 address or fully qualified domain name (FQDN).

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the IPv6 address of the peer end. If the encapsulation mode of an IPSec proposal is set to TRANSPORT, the peer IPv6 address NO must be the same as the destination IPv6 address of the ACL rule. Otherwise, encrypted packets fail to be decrypted.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the peer name used by an IPv6 IKE negotiation.

NO

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the authenticator of the pre-shared key in IPv6 networks. The NO two negotiation ends must be configured with the same authenticator. Indicates whether to enable the Dead Peer Detection NO (DPD) function in IPv6 networks.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the IPv6 DPD idle time. If the local end does not receive encrypted packets for a period specified by this parameter, it sends NO a DPD packet to perform dead peer detection. Time required to transmit DPD packets varies with network conditions. Indicates the interval for sending the IPv6 DPD detection frame. The interval at which IPv6 DPD detection frames NO are sent may slightly vary in various network environments such as network congestion, delay, and jitter. Indicates the number of retransmissions NO after the IPv6 DPD detection fails.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the IPv6 address that is used by the local end in IPv6 IKE negotiation. This IP address can be set to either 0:0:0:0:0:0:0:0 or a device IPv6 address configured at the local end. If this parameter is set to 0:0:0:0:0:0:0:0, the BS NO automatically uses a local interface IP address to negotiate with the peer end. If multiple interface IPv6 addresses are configured for a port, it is recommended that this parameter be set to one of the IP addresses. Indicates the cabinet number of the IPv6 IKE peer board. Indicates the subrack number of the IPv6 IKE peer board.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024 LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024 LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

NO

Yes

Indicates the slot number of the IPv6 NO IKE peer board.

NO

Yes

Indicates the ID of the IKE proposal.

YES

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the encryption algorithm used in the IKE proposal. The Data Encryption Standard (DES) is an internationally used data encryption algorithm, which uses a 56-bit key. The 3DES is also an internationally used encryption algorithm, which NO uses a 168-bit key. The Advanced Encryption Standard (AES) is an advanced encryption algorithm, which provides three types of key of different lengths: 128, 192, and 256 bits. Thus, different protection levels are available. For details, see RFC2401.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the authentication algorithm used in the IKE proposal. The MessageDigest Algorithm 5 (MD5) uses a 128bit secret key, whereas the Secure Hash Algorithm 1 (SHA1) uses a 160bit secret key. The MD5 algorithm NO supports faster calculation but lower security than the SHA1 algorithm. For details, see RFC2409. The AESXCBC-MAC-96 algorithm is used only in IKEv2. For details about this algorithm, see RFC3566.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the authentication mode used in the IKE NO proposal. For details, see RFC2409.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the DiffieHellman (DH) group of the IKE proposal. The core technology used in an IKE proposal is the Diffie-Hellman (DH) exchange technology. The DH exchange technology is used NO to calculate private information based on public information. It is mathematically proven that decrypting the DH information is impractical due to calculation complexity.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the life cycle of an ISAKMP SA. ISAKMP refers to Internet Security Association and Key Management Protocol, and SA refers to security association. IKE negotiation requires a long time to calculate DiffieHellman (DH) keys. It is recommended that this parameter be set to greater than 10 minutes so NO that the update of the ISAKMP SA does not affect the secure communication. Before the SA life cycle elapses, local and peer ends will negotiate with each other to generate a new SA to replace the original one. The new SA is used upon completion of the negotiation, and the original SA is automatically Indicates the Pseudo-random Function (PRF) algorithm used in IKEv2. The PRF algorithm is used to generate the NO materials required for IKE authentication and encryption. For details about how to generate materials, see RFC4306. Indicates the cabinet number of the board that adopts the IKE security proposal.

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

NO

NO

Yes

LOFD-003009 / TDLOFD-003009

Indicates the subrack number of the board that adopts the IKE security proposal.

NO

NO

Yes

LOFD-003009 / TDLOFD-003009

Indicates the slot number of the board NO that adopts the IKE security proposal. Indicates the number of the cabinet housing the board where a YES transmission resource group is established. Indicates the number of the subrack that houses the board where a YES transmission resource group is established. Indicates the number of the slot corresponding to the board where a transmission resource group is established.

NO

Yes

LOFD-003009 / TDLOFD-003009

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

YES

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the ID of a transmission YES resource group.

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the destination IP YES address of passingby traffic.

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the subnet mask of the destination IP address of the YES service traffic bound to a transmission resource group.

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the bearer type of transmission YES resource group.

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the type of sub-board on the board where a YES transmission resource group is established.

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the type of port where a transmission YES resource group is carried.

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the number of the port where a transmission resource group is carried.

YES

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates whether to perform ARP spoofing checks. If this parameter is set to ENABLE, an alarm is reported when ARP spoofing NO attacks occur. If this parameter is set to DISABLE, no alarm is reported when ARP spoofing attacks occur.

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the ARP spoofing alarm threshold. When the ARP spoofing check switch is turned on, an ARP spoofing alarm is reported if the number of ARP update attempts reaches this threshold within one NO minute. Note that the number of ARP update attempts from trusted MAC addresses is not counted. This alarm is cleared if no ARP update attempt is made in one minute after the ARP spoofing alarm is reported. Indicates whether to enable APR learning strict. ARP learning strict is a function that enables a BS to learn the acknowledgement packets in response NO to only ARP request packets sent by itself. With ARP learning strict, the BS can reject most ARP request and acknowledge packet attacks.

NO

No

LOFD-003014 / TDLOFD-003014

NO

No

LOFD-003014 / TDLOFD-003014

Indicates whether to report an alarm when the number of invalid packets received by a BS exceeds the specified threshold. If this parameter is set to ENABLE, an alarm is reported when the number of invalid packets received by a BS exceeds the NO specified threshold. If this parameter is set to DISABLE, no alarm is reported when the number of invalid packets received by a BS exceeds the specified threshold. Invalid packets are those filtered according to the packet filter criteria. Indicates the threshold for the excessive flood packet alarm. When Invalid Packet Check Switch is set to ENABLE, the system measures the RX rate of invalid packets every 10 seconds. If the measured value NO exceeds this threshold, an excessive invalid packet alarm is reported. The alarm is cleared if the RX rate of invalid packets keeps below the threshold for 5 consecutive minutes.

NO

No

LOFD-003014 / TDLOFD-003014

NO

No

LOFD-003014 / TDLOFD-003014

Indicates whether to detect IPSec packet NO replay. Indicates the IPSec anti-replay alarm NO threshold.

NO

No

LOFD-003014 / TDLOFD-003014

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the type of NO physical port.

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the number of a port. Indicates the source MAC address of an invalid packet. Indicates the destination MAC address of an invalid packet. Indicates the VLAN ID of an invalid packet.

NO NO

NO NO

Yes Yes

LOFD-003014 / TDLOFD-003014 LOFD-003014 / TDLOFD-003014 LOFD-003014 / TDLOFD-003014 LOFD-003014 / TDLOFD-003014

NO

NO

Yes

NO

NO

Yes

Indicates the type of MAC-layer protocol used by an invalid packet. A BS interprets only the supported MACNO layer protocols and only displays the protocol numbers of other MAC-layer protocols. Indicates the source IP address of an NO invalid packet. Indicates the destination IP NO address of an invalid packet.

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014 LOFD-003014 / TDLOFD-003014

NO

Yes

Indicates the protocol used at the IP layer of an invalid packet. A BS interprets only the supported IP-layer NO protocols and only displays the protocol numbers of other IP-layer protocols. Indicates the source port number of an NO invalid packet. Indicates the destination port NO number of an invalid packet. Indicates at most the first 64 bytes of NO an invalid packet. Indicates the index of the IPv6 interface. YES

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014 LOFD-003014 / TDLOFD-003014 LOFD-003014 / TDLOFD-003014 LBFD-003006 / TDLBFD-003006

NO

Yes

NO

Yes

YES

No

Indicates the type of the IPv6 interface, NO which can be set to NORMAL or VLAN. Indicates the number of the cabinet housing the NO board where the IPv6 interface is located. Indicates the subrack number of the board where the NO IPv6 interface is located. Indicates the slot number of the board NO where the IPv6 interface is located. Indicates the type of sub-board on the board where the NO IPv6 interface is located.

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

YES

No

LBFD-003006 / TDLBFD-003006

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the port type of IPv6 interface.

NO

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the port number of the IPv6 NO interface.

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the ID of the VLAN-type IPv6 NO interface. Indicates the maximum NO transmission unit of the IPv6 interface. Indicates whether an IPv6 interface is NO already activated. Indicates the valid link-local address of NO an IPv6 interface. Indicates the number of valid global unicast addresses of an IPv6 interface.

YES

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006 LBFD-003006 / TDLBFD-003006 LBFD-003006 / TDLBFD-003006

NO

Yes

NO

Yes

NO

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates the list of valid global unicast NO addresses of an IPv6 interface. Indicates the number of valid NO multicast addresses of an IPv6 interface. Indicates the list of valid multicast addresses of an IPv6 interface. NO

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates whether to enable the IPv6 interface to detect NO address conflicts during neighbor discovery. Indicates the number of detection times during the NO neighbor discovery procedure of the IPv6 interface. Indicates the time for the IPv6 interface to start a NO neighbor discovery procedure. Indicates the interval between the time the IPv6 interface reinitiates neighbor discovery NO and the time neighbor discovery fails or the ND table entry becomes invalid. Indicates whether to enable the IPv6 interface to NO automatically generate a link local address. Indicates the stateless automatic configuration switch NO of the IPv6 interface. Indicates the ID of an IP path. YES

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

Yes

LBFD-003006 / TDLBFD-003006

YES

No

None

Indicates the cabinet number of NO the board where the IP path is located. Indicates the subrack number of NO the board where the IP path is located.

NO

No

None

NO

No

None

Indicates the slot number of the board NO where the IP path is located.

YES

No

None

Indicates the physical port type of NO the IP path.

YES

No

None

Indicates the number of the NO physical port of the IP path.

NO

No

None

Indicates the type of the IP path. QOS indicates that this IP path is used to carry the service with specified Quality of Service (QoS), that is, with a specified NO DSCP. ANY indicates that this IP Path can be used to carry services of any QoS and hence is used to carry the service without a specified DSCP.

NO

No

None

Indicates the differentiated services code point NO (DSCP) of the services carried on an IP path.

YES

No

None

Indicates the local IP address of an IP path. The value 0.0.0.0 indicates NO that the local IP address needs to be negotiated.

YES

No

None

Indicates the peer IP address of the IP NO path.

YES

No

None

Indicates the ID of the adjacent signaling point to which the IP path belongs. This parameter is valid only when the APPTYPE parameter is set to NO X2 and must be set to the ID of the associated X2 interface. Note that the SCTP link referenced by this X2 interface must be an IPv4 SCTP link.

YES

No

None

Indicates the type of transport resource for the IP path. The value HQ indicates high-quality transport resources, and the value LQ indicates low-quality NO transport resources. This parameter must be set in the hybridtransmission scenario. In other scenarios, the default value of this parameter is used. Indicates the application type of IP path.

NO

No

None

NO

YES

No

None

Indicates whether to enable the PING detection to check the IP path. The PING detection is used to check the connectivity of an IP path. If the PING detection is disabled in the firewall located in the transport network or in the NO CN equipment, a detection failure will be resulted, which will cause the reestablishment of the S1 interface and disrupt services in the cell. Therefore, this parameter must be set to DISABLE under such scenarios. Indicates the actual real-time traffic NO transmitted on the IP path. Indicates the actual real-time traffic NO received on the IP path.

NO

No

None

NO

Yes

None

NO

Yes

None

Indicates the actual non-real-time traffic NO transmitted on the IP path. Indicates the actual non-real-time traffic NO received on the IP path. Indicates the actual TX bandwidth reserved for the nonNO real-time service transmitted on the IP path. Indicates the actual RX bandwidth reserved for the nonNO real-time service received on the IP path. Indicates the check result for an IP path. If ping detection and GTP-U static detection are simultaneously NO enabled, the parameter value uses the result of the GTP-U static detection. Indicates the ID of the transmission resource group established on an IP path. Indicates the description about the peer of the IP path.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

YES

No

None

NO

NO

No

None

Indicates the type of sub-board on the NO board where the IP path is established.

YES

No

None

Indicates whether the IP path joins a transmission resource group. If this parameter is set to DISABLE, the IP NO path is established on the default transmission resource group on a specific physical port. Indicates the ID of an IPv6 path, which YES identifies a unique IPv6 path. Indicates whether the IPv6 path joins a transmission resource group.

NO

No

None

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

NO

No

Indicates the ID of the transmission resource group to NO which an IPv6 path is added. Indicates the index of the IPv6 interface NO used by an IPv6 path.

YES

No

YES

No

Indicates the type of IPv6 path. The value QOS indicates that the current IPv6 path only carries services of a fixed NO QoS. The value ANY indicates that the current IPv6 path can carry services of any QoS. Indicates the Differentiated Services Code Point (DSCP) of NO services allowed to be carried on an IPv6 path. Indicates the local IPv6 address of an IPv6 path. This IPv6 NO address must be a global unicast address.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the peer IPv6 address of an IPv6 path. This IPv6 NO address must be a global unicast address. Indicates the ID of the adjacent signaling point to which the IPv6 path belongs. This parameter is valid only when the APPTYPE parameter is set to NO X2 and must be set to the ID of the associated X2 interface. Note that the SCTP link referenced by this X2 interface must be an IPv6 SCTP link.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the application type of IP path.

NO

YES

No

None

Indicates whether to enable ping detection for an IPv6 path. Ping NO detection can be used to check the connectivity of an IPv6 path. Indicates the actual real-time services NO transmitted on an IPv6 path. Indicates the actual real-time services NO received on an IPv6 path. Indicates the actual non-real-time NO services transmitted on an IPv6 path. Indicates the actual non-real-time NO services received on an IPv6 path. Indicates the TX bandwidth reserved for non-real-time NO services on an IPv6 path. Indicates the RX bandwidth reserved for non-real-time NO services on an IPv6 path. Indicates the ping check result of the IPv6 path.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

Yes

NO

Yes

NO

Yes

NO

Yes

NO

Yes

NO

NO

Yes

Indicates the description about NO the peer of the IPv6 path.

NO

No

Indicates the source IP address of an IP path route. The source IP address YES must be the same as the configured device IP address.

YES

No

None

Indicates the destination IP address of an IP path route.

YES

YES

No

None

Indicates the type of transport resource carried on an IP path route. The value HQ indicates NO high-quality transport resources, and the value LQ indicates low-quality transport resources. Indicates the next hop IP address of an IP path route. The next hop IP address and the configured device NO IP address must be on the same network segment, but cannot be the same.

YES

No

None

YES

No

None

Indicates the ID of an IP PM session of YES an NE.

YES

No

LOFD-00301201 / TDLOFD-00301201

Indicates the local IP address of an IP PM session. This IP address excluding 0.0.0.0 must be NO configured at the Ethernet port, Ethernet trunk, or loopback interface.

YES

No

LOFD-00301201 / TDLOFD-00301201

Indicates the peer IP address of the IP PM session. This IP address must be a valid IP address of Class A, B, or C NO and different from any existing IP address of the local end. In addition, it cannot be set to 0.x.x.x or 127.x.x.x.

YES

No

LOFD-00301201 / TDLOFD-00301201

Indicates the Differentiated Services Code NO Point (DSCP) of an IP PM session.

YES

No

LOFD-00301201 / TDLOFD-00301201

Indicates that the activation direction of the IP PM session. For this parameter to be valid, the peer must also support the IP PM session. If this parameter is set to NO UP, the IP PM session initiated by the BS is activated. If this parameter is set to BIDIR, the IP PM sessions initiated by BS and the peer are activated. Indicates the roundtrip delay calculated by an IP PM session detection. The round-trip delay is the time that is NO consumed to transmit IP PM detection packets to and fro between the local and peer ends.

NO

No

LOFD-00301201 / TDLOFD-00301201

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the DL jitter calculated by an IP PM session detection.

NO

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the UL jitter calculated by an IP PM session detection.

NO

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the DL byte loss rate calculated by an IP NO PM session detection.

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the UL byte loss rate calculated by an IP NO PM session detection.

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the UL activation status of an IP PM session.

NO

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the DL activation status of an IP PM session.

NO

NO

Yes

LOFD-00301201 / TDLOFD-00301201

Indicates the type of IP PM session. A triplet consists of the local IP address, peer IP address, and NO protocol type; a quadbit consists of the local IP address, peer IP address, protocol type, and DSCP.

NO

No

LOFD-00301201 / TDLOFD-00301201

Indicates whether to bind the IP PM session to an IP path. If the IP PM session is bound to an IP path, the IP PM session uses the local and peer IP addresses of the IP path in data transmission. In addition, if TXBWASW or RXBWASW is set NO to ON and TCSW is set to ENABLE in the algorithm for the transmission resource group associated with the IP path, the system dynamically adjusts the TX or RX bandwidth of the transmission resource group based on the IP PM detection result.

NO

No

LOFD-00301201 / TDLOFD-00301201

Indicates the ID of the IP path to which NO an IP PM session is bound. Indicates whether the DSCP value of NO a DL IP PM session changes. Indicates the initial DSCP value of a DL NO IP PM session. Indicates the modified DSCP NO value of a DL IP PM session. Indicates the time when the DSCP NO value of a DL IP PM session changes. Indicates whether the DSCP value of an UL IP PM session changes. NO

YES

No

LOFD-00301201 / TDLOFD-00301201

NO

Yes

LOFD-00301201 / TDLOFD-00301201 LOFD-00301201 / TDLOFD-00301201 LOFD-00301201 / TDLOFD-00301201

NO

Yes

NO

Yes

NO

Yes

None

NO

Yes

None

Indicates the initial DSCP value of an UL IP PM session. Indicates the modified DSCP value of an UL IP PM session. Indicates the time when the DSCP value of an UL IP PM session changes. Indicates the version of the negotiated data, when the status of IP PM is UP.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the cabinet number of YES the board where the IP route is located. Indicates the subrack number of YES the board where the IP route is located. Indicates the slot number of the board YES where the IP route is located.

NO

No

None

NO

No

None

YES

No

None

Indicates the type of sub-board on the YES board where the IP route is established.

YES

No

None

Indicates the type of YES port.

NO

No

None

Indicates the port number.

YES

NO

No

None

Indicates the type of route. If this parameter is set to NEXTHOP, all the IP packets that meet the route direction are first forwarded to the specified next hop YES IP address. If this parameter is set to IF, all the IP packets that meet the route direction are first forwarded to the specified egress port.

YES

No

None

Indicates the destination IP address of the route.

YES

YES

No

None

Indicates the subnet mask for the destination IP YES address of the route.

YES

No

None

Indicates the IP address of the next YES hop.

NO

No

None

Indicates the priority of the routing table entry. A smaller NO parameter value indicates a higher priority.

NO

No

None

Indicates the type of the IP route. A static host route is a manually configured route with the subnet mask set to 255.255.255.255. A static gateway route is a manually configured route, in which the subnet mask is not set to 255.255.255.255 and the next hop IP address is on a different network segment from the NO egress port IP address. A dynamic host route is a dynamically generated route with the subnet mask set to 255.255.255.255. A dynamic gateway route is a dynamically generated route, in which the subnet mask is not set to 255.255.255.255 and the next hop IP address is on a Indicates the description about NO the destination of the route.

NO

Yes

None

NO

No

None

Indicates the type of NO the port.

NO

Yes

None

Indicates the port number.

NO

NO

Yes

None

Indicates the destination IPv6 YES address of the static IPv6 route.

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the prefix length of the destination IPv6 YES address of the static IPv6 route. Indicates the next hop type of static IPv6 route. If this parameter is set to NEXTHOP, all the IP packets meeting the route direction are first forwarded to the next hop IPv6 address, and then forwarded to other addresses.

YES

No

LBFD-003006 / TDLBFD-003006

YES

NO

No

LBFD-003006 / TDLBFD-003006

Indicates the type of next hop IPv6 YES address.

YES

No

LBFD-003006 / TDLBFD-003006

Indicates the next hop IPv6 address of YES the static IPv6 route. Indicates the index of the IPv6 interface YES to which a static IPv6 route belongs. Indicates the priority of a static IPv6 route. A smaller NO parameter value indicates a higher priority.

YES

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

Indicates the type of the static IPv6 route. A static host route is a manually configured route with a 128-bit prefix. A static gateway route is a manually configured route with a non-128-bit prefix, with the next hop IP address on a different network segment from the egress port IP address. A dynamic NO host route is a dynamically learned (not manually configured) route with a 128-bit prefix. A dynamic gateway route is a dynamically learned (not manually configured) route with a non-128-bit prefix, with the next hop IP address on a different segment from the egress port IP address. Indicates the description about NO the destination of a static IPv6 route. Indicates the cabinet number of the port to which the YES IPSec policy group is bound. Indicates the subrack number of the port to which the YES IPSec policy group is bound. Indicates the slot number of the port to which the IPSec policy group is bound.

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

YES

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the type of sub-board on the board with the port YES to which the IPSec policy group is bound.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the type of port to which the YES IPSec policy group is bound.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the number of the port to which the IPSec policy group is bound.

YES

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec policy NO group. Indicates the number of the port to which the IPv6 security policy group is bound.

YES

No

LOFD-003009 / TDLOFD-003009 LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

YES

YES

No

Indicates the name of the IPv6 security NO policy group. Indicates the ID of the IPSec tunnel pair. It uniquely identifies a pair of primary and secondary IPSec tunnels.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

YES

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the name of the primary IPSec policy group. The primary IPSec NO tunnel uses an IPSec policy in the primary IPSec policy group. Indicates the ID of the primary IPSec policy. The primary IPSec tunnel uses the primary IPSec NO policy, which is identified by this parameter and the MSPGN parameter together. Indicates the name of the secondary IPSec policy group. The secondary NO IPSec tunnel uses an IPSec policy in the secondary IPSec policy group. Indicates the ID of the secondary IPSec policy. The secondary IPSec tunnel uses the secondary IPSec policy, which is identified by this parameter and the SSPGN parameter together. Indicates the ID of the BFD session referenced by the primary IPSec tunnel.

YES

No

LOFD-003009 / TDLOFD-003009

YES

No

LOFD-003009 / TDLOFD-003009

YES

No

LOFD-003009 / TDLOFD-003009

NO

YES

No

LOFD-003009 / TDLOFD-003009

NO

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the ID of the BFD session referenced by the secondary IPSec tunnel.

NO

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the IPSec policy in use. If the primary IPSec tunnel is used, the IPSec policy in use is the primary IPSec NO policy. If the secondary IPSec policy is used, the IPSec policy in use is the secondary IPSec policy.

NO

Yes

LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec policy YES group.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the sequence No. of the IPSec policy group. YES The smaller the number, the higher the priority.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the ID of the access control list.

NO

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the name of the IPSec NO proposal.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the name of the IKE peer that NO is referenced by the IPSec policy.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the perfect forward secrecy (PFS) value. In the second phase of IPSec negotiation, PFS enables the BS to use a key that is not derived from the first-phase key, ensuring that the two keys are independent of each other. According to PFS, a key protects a unique set of data. The elements used NO to generate keys are not reusable. If a key is decrypted, other keys are still secure. If the IPSec policy is used to initiate IPSec negotiation, a PFS exchange is launched. If the PFS is assigned to the local end, then the PFS exchange is required when the negotiation is launched at the peer end. The DH

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the configuration mode of the IPSec SA life cycle. The value GLOBAL indicates that the life cycle applies to all IPSec SAs of the BS, and the value LOCAL indicates the life cycle applies only to the current IPSec NO SA. If this parameter is set to GLOBAL, the value of Lifetime Based On Time is permanently set to 3600, the value of Lifetime Based On Traffic is permanently set to 69120000.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the life cycle of an IPSec SA. An IPSec SA becomes invalid once its life cycle specified by this parameter elapses. Before the life cycle of an IPSec SA elapses, the IPSec policy is used in an attempt to establish a new IPSec SA through negotiation to ensure secure transmission; before the negotiation is NO complete, the original IPSec SA is still used. After the negotiation is complete, the new SA is immediately. IPSec SA negotiation takes a period. To prevent SA updating from affecting communication security, a life cycle longer than 900 seconds is recommended. Indicates the effective traffic under the IPSec policy. Indicates the cabinet number of the board that adopts the IPSec policy. Indicates the subrack number of the board that adopts the IPSec policy.

NO

No

LOFD-003009 / TDLOFD-003009

NO

NO

No

LOFD-003009 / TDLOFD-003009

NO

NO

Yes

LOFD-003009 / TDLOFD-003009

NO

NO

Yes

LOFD-003009 / TDLOFD-003009

Indicates the slot number of the board NO that adopts the IPSec policy.

NO

Yes

LOFD-003009 / TDLOFD-003009

Indicates the size of the IPSec packet anti-replay window. If the value of this parameter is set to 0, the IPSec packet anti-replay function is disabled. If the value of this parameter is set to 32, 64, 128, 256, 512, 1024, 2048 or 4096, the system checks whether the packets are NO duplicate in the window. A packet is discarded if it has a duplicate packet or its sequence number is smaller than any packet in the window. The window slides if the sequence number of the packet is larger than any packet that is received in the window.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the name of the IPv6 IPSec YES policy group.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the sequence number of the IPv6 IPSec policy. A larger YES value of this parameter indicates a lower priority.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the type of the ID of the access NO control list.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the ID of the IPv4 ACL.

NO

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the ID of the IPv6 ACL.

NO

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the name of the security NO proposal.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the name of the IPv6 IKE peer that is referenced NO by the IPv6 IPSec policy.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the perfect forward secrecy (PFS) value. In the second phase of IPSec negotiation, PFS enables the BS to use a key that is not derived from the first-phase key, ensuring that the two keys are independent of each other. According to PFS, a key protects a unique set of data. The elements used NO to generate keys are not reusable. If a key is compromised, other keys are still secure. If the IPSec policy is used to initiate IPSec negotiation, a PFS exchange is launched. If the PFS is assigned to the local end, then the PFS exchange is required when the negotiation is launched at the Indicates the configuration mode of the IPv6 IPSec SA life cycle. The value GLOBAL indicates that the life cycle applies to all IPSec SAs of the BS, and the value LOCAL indicates NO the life cycle applies only to the current IPSec SA. When this parameter is set to GLOBAL, Lifetime Based On Time is 3600s and Lifetime Based On Traffic is 69120000 KB.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the life cycle of an IPv6 IPSec SA. When the lifetime reaches a specified value, the IPv6 IPSec SA becomes invalid. Before the life cycle of an IPv6 IPSec SA elapses, the IPSec policy is used in an attempt to establish a new IPv6 IPSec SA through negotiation to ensure secure transmission; before NO the negotiation is complete, the original IPv6 IPSec SA is still used. After the negotiation is completed, the new SA is immediately used. IPv6 IPSec SA negotiation takes a period. To prevent SA updating from affecting communication security, a life cycle longer than 900 seconds is

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the effective traffic of the IPv6 IPSec policy.

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the cabinet number of the board that adopts the IPv6 IPsec policy. Indicates the subrack number of the board that adopts the IPv6 IPSec policy.

NO

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024 LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

NO

NO

Yes

Indicates the slot number of the board NO that adopts the IPv6 IPSec policy.

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003024 / TDLOFD-003024

Indicates the name of the IPSec YES proposal.

YES

No

LOFD-003009 / TDLOFD-003009

Indicates the encapsulation mode of an IPSec proposal, which can be set to TUNNEL or TRANSPORT. In TRANSPORT mode, only data is encrypted. In TUNNEL mode, the whole IP packet is protected, and a new IP header is added to the original IP packet. The source IP address and the NO destination IP address of the new IP header are the IP addresses of two ends of the security tunnel. Both the TRANSPORT mode and the TUNNEL mode are used for end-to-end IPSec protection. The TUNNEL mode, however, is also applied to the protection of a certain segment.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the security protocol used in an IPSec proposal. The value AH indicates the Authentication Header (AH) protocol specified in RFC2402. The value ESP indicates the Encapsulating NO Security Payload (ESP) protocol specified in RFC2406. The value AH_ESP indicates that the ESP protocol is preferentially used to protect packets, but not the AH protocol. Indicates the authentication algorithm used in the AH. The Message-Digest Algorithm 5 (MD5) algorithm uses a 128-bit secret key, whereas the Secure NO Hash Algorithm 1 (SHA1) uses a 160bit secret key. The MD5 algorithm features faster calculation but lower security than the SHA1 algorithm.

NO

No

LOFD-003009 / TDLOFD-003009

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the authentication algorithm used in the ESP.

NO

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the encryption algorithm NO used in the ESP.

NO

No

LOFD-003009 / TDLOFD-003009

Indicates the cabinet number of the board that adopts the IPSec proposal. Indicates the subrack number of the board that adopts the IPSec proposal.

NO

NO

Yes

LOFD-003009 / TDLOFD-003009

NO

NO

Yes

LOFD-003009 / TDLOFD-003009

Indicates the slot number of the board NO that adopts the IPSec proposal. Indicates whether to enable the local NO maintenance Ethernet port. Indicates the physical layer status of the local NO maintenance Ethernet port.

NO

Yes

LOFD-003009 / TDLOFD-003009

NO

Yes

None

NO

Yes

None

Indicates the number of discarded packets that are received at the local maintenance Ethernet port. Indicates the number of packets received at the local maintenance Ethernet port. Indicates the number of discarded packets that are transmitted at the local maintenance Ethernet port. Indicates the number of packets transmitted at the local maintenance Ethernet port.

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

NO

NO

Yes

None

Indicates the IP address for local maintenance. The value of this parameter must meet the following conditions: (1) It must be a valid IP address of Class A, B, or C, and cannot be set to 0.x.x.x or 127.x.x.x. (2) It must be different from the local IP address of any remote NO maintenance channel and from any device IP address. (3) It must be on different network segments from the IP address of any remote maintenance channel and from any device IP address. (4) It must be different from any IP address configured on other ports.

NO

No

None

Indicates the subnet mask of a local maintenance channel. This subnet mask must NO be a valid mask address and cannot be 0.0.0.0 or 255.255.255.255.

NO

No

None

Indicates the IPv6 address of the local maintenance channel. This IPv6 NO address must be a global unicast address or a linklocal address. Indicates the prefix length of the IPv6 address of a local NO maintenance channel.

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

Indicates the status of the IPv6 address of the local NO maintenance channel.

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates the time period during which the IPv6 address of the local NO maintenance channel is in valid state.

NO

Yes

LBFD-003006 / TDLBFD-003006

Indicates the time period during which the IPv6 address of the local maintenance channel is in preferred state. The valid state is categorized into the preferred state and the deprecated state. In preferred state, the address NO can be freely used. In deprecated state, the connections previously established through this address are still usable, whereas any connection newly established through this address is not usable. Indicates the cabinet number of YES the board where the port is located. Indicates the subrack number of YES the board where the port is located. Indicates the slot number of the board YES where the port is located.

NO

Yes

LBFD-003006 / TDLBFD-003006

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

NO

No

YES

No

Indicates the port type.

YES

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the port number.

YES

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the switch for limiting the line NO rate at the port.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the UL committed information rate after rate limitation is configured at a port.

NO

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the Committed Burst Size (CBS) after NO rate limitation is configured at a port.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the Excess Burst Size (EBS) after rate NO limitation is configured at a port.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the type of sub-board on the YES board where a port is located.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the DL committed information rate after rate limitation is configured at a NO port. This parameter computes the value of Physical Port Down Link Admission.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102

Indicates the number of the cabinet where the MLPPP group is located. Indicates the number of the subrack where the MLPPP group is located. Indicates the number of the slot where the MLPPP group is located.

YES

NO

No

LBFD-00300403 / TDLBFD-00300403

YES

NO

No

LBFD-00300403 / TDLBFD-00300403

YES

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of the MLPPP group.

YES

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates whether an MLPPP group supports the multiclass feature. If this parameter is set to ENABLE, the MLPPP group NO supports the Class of Service (CoS) feature and four or eight service types of different priorities. Indicates the authentication type of the MLPPP group.

NO

No

LBFD-00300403 / TDLBFD-00300403

NO

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the authentication user NO name of an MLPPP group.

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the authentication password.

NO

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the local IP address. If this parameter is set to 0.0.0.0, this IP address needs to be negotiated. If this parameter is not set NO to 0.0.0.0, it must be set to a valid IP address of class A, B, or C but must not be the reserved address 0.x.x.x or 127.x.x.x.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the subnet mask of the local IP address. If this NO parameter is set to 0.0.0.0, it needs to be negotiated.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the peer IP address. When the eNodeB is connected to a peer equipment, the peer IP address can be either user-specified NO or set to 0.0.0.0. If this parameter is set to 0.0.0.0, this IP address is obtained by means of negotiation. Indicates the MP/MC head option NO of the MLPPP.

NO

No

LBFD-00300403 / TDLBFD-00300403

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates whether to enable PPP multi- NO frame multiplexing.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the fragment size of an NO MLPPP group.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the maximum length of NO the PPP MUX subframe.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the maximum length of NO the PPP MUX frame.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the timeout duration of a PPP MUX combination. If the PPP MUX combination takes NO longer time than this parameter value, an alarm related to the PPP MUX combination timeout is reported.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of classes of service.

NO

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates whether to enable IP header NO compression.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the threshold above which the MLPPP NO packet loss alarm is generated. Indicates the threshold below which the MLPPP NO packet loss alarm is cleared.

NO

No

LBFD-00300403 / TDLBFD-00300403

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the status NO of an MLPPP group.

NO

Yes

LBFD-00300403 / TDLBFD-00300403

Indicates the status of the IPCP NO protocol.

NO

Yes

LBFD-00300403 / TDLBFD-00300403

Indicates the status NO of the PPP MUX.

NO

Yes

LBFD-00300403 / TDLBFD-00300403

Indicates the negotiation result of NO the local IP address. Indicates the negotiation result of NO the local IP mask. Indicates the negotiation result of NO the peer IP address.

NO

Yes

LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403

NO

Yes

NO

Yes

Indicates the negotiation result of NO the multi-class PPP. Indicates the negotiation result of NO the maximum RX unit. Indicates the negotiation result of NO the PPP MUX. Indicates the negotiation result of NO the address field and control field. Indicates the negotiation result of the protocol field compression. Indicates the negotiation result of the IPHC. Indicates the number of packets received. Indicates the number of packets sent. Indicates the RX traffic. Indicates the TX traffic. Indicates the number of IP addresses of an MLPPP group. Indicates the list of IP addresses of an MLPPP group. NO

NO

Yes

LBFD-00300403 / TDLBFD-00300403

NO

Yes

LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403

NO

Yes

NO

Yes

NO

Yes

LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403

NO

NO

Yes

NO

NO

Yes

NO NO NO

NO NO NO

Yes Yes Yes

NO

NO

Yes

NO

NO

Yes

Indicates the type of sub-board on the board where an YES MLPPP group is established.

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of bytes received. Indicates the number of discarded packets received. Indicates the number of bytes transmitted. Indicates the number of discarded packets transmitted. Indicates the number of the cabinet where the MLPPP sublink is located. Indicates the number of the subrack where the MLPPP sublink is located. Indicates the number of the slot where the MLPPP sublink is located. Indicates the number of the MLPPP sublink.

NO

NO

Yes

LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

YES

NO

No

LBFD-00300403 / TDLBFD-00300403

YES

NO

No

LBFD-00300403 / TDLBFD-00300403

YES

YES

No

LBFD-00300403 / TDLBFD-00300403

YES

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of the MLPPP group.

NO

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of the subrack housing the board where the NO E1/T1 port carrying the MLPPP sublink is located. Indicates the number of slot holding the board where the E1/T1 port carrying the MLPPP sublink is located.

NO

No

LBFD-00300403 / TDLBFD-00300403

NO

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of the NO E1/T1 port carrying the MLPPP sublink.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of the E1/T1 slot carrying the MLPPP sublink. Timeslot 0 cannot be configured. In E1 mode, timeslot 1 to NO 31 can be configured. In T1 mode, only timeslots 1 to 24 can be configured. Other timeslots are not used.

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the Maximum Receive Unit (MRU). The received packet whose length is greater than this parameter value is discarded.

NO

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates whether to enable protocol field NO compression.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates whether to enable the compression of the NO address field and control field.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the timeout duration of NO the MLPPP sublink negotiation.

NO

No

LBFD-00300403 / TDLBFD-00300403

Indicates the type of sub-board where an YES MLPPP sublink is established.

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the type of sub-board where an NO MLPPP group is established.

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the status of the MLPPP NO sublink.

NO

Yes

LBFD-00300403 / TDLBFD-00300403

Indicates the status of the Link Control NO Protocol (LCP) protocol.

NO

Yes

LBFD-00300403 / TDLBFD-00300403

Indicates the negotiation result of NO the maximum RX unit. Indicates the negotiation result of NO the protocol field compression. Indicates the negotiation result of the Address-AndNO Control-FieldCompression (ACFC).

NO

Yes

LBFD-00300403 / TDLBFD-00300403

NO

Yes

LBFD-00300403 / TDLBFD-00300403

NO

Yes

LBFD-00300403 / TDLBFD-00300403

Indicates the type of sub-board on the board where the NO E1/T1 port carrying the MLPPP sublink is located.

YES

No

LBFD-00300403 / TDLBFD-00300403

Indicates the number of packets received. Indicates the number of bytes received. Indicates the number of discarded packets received. Indicates the number of packets transmitted. Indicates the number of bytes transmitted. Indicates the number of discarded packets transmitted.

NO

NO

Yes

LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403 LBFD-00300403 / TDLBFD-00300403

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

Indicates the master/slave flag of the remote YES maintenance channel.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the local IP address of a remote maintenance channel.

NO

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the local subnet mask of a remote maintenance channel.

NO

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the peer IP address of the remote maintenance NO channel, that is, the IP address of the M2000.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the subnet mask of the peer IP address for the NO remote maintenance channel.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the cabinet number of the board where the NO remote maintenance channel is located.

NO

No

LBFD-004002 / TDLBFD-004002

Indicates the subrack number of the board where the NO remote maintenance channel is located. Indicates the slot number of the board where the remote NO maintenance channel is located. Indicates the bearer type of a remote NO maintenance channel. Indicates whether to add a route for the remote maintenance channel. If this parameter is set to YES, a route is automatically added for the remote maintenance channel according to the configurations. If this parameter is set to NO, operators must run the ADD IPRT command to NO manually add a route for the remote maintenance channel when the following conditions are met: The peer IP address and the device IP address are not on the same network segment and the network segment containing the device IP address does not cover that containing the peer IP address.

NO

No

LBFD-004002 / TDLBFD-004002

YES

No

LBFD-004002 / TDLBFD-004002

NO

No

LBFD-004002 / TDLBFD-004002

NO

No

LBFD-004002 / TDLBFD-004002

Indicates the destination IP address used in the routing table for a remote maintenance channel. This IP NO address is a Network ID, which is usually the address of the network where the M2000 is located.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the subnet mask of the destination IP address used in the routing table for a remote NO maintenance channel, that is, the destination network segment where the EMS is located.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the type of route in the routing table for a remote maintenance channel. If this parameter is NO set to NEXTHOP, the next hop IP address must be specified in the routing table.

NO

No

LBFD-004002 / TDLBFD-004002

Indicates the type of egress port used in the route for a NO remote maintenance channel.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the number of the egress port used in the route for a NO remote maintenance channel.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the priority of the route for the remote maintenance channel. The NO priority of the route has a negative correlation with the value of this parameter. Indicates the next hop IP address of the route added for NO a remote maintenance channel. Indicates the status of a remote NO maintenance channel. Indicates whether the remote maintenance channel is being used.

NO

No

LBFD-004002 / TDLBFD-004002

YES

No

LBFD-004002 / TDLBFD-004002

NO

Yes

LBFD-004002 / TDLBFD-004002

NO

NO

Yes

LBFD-004002 / TDLBFD-004002

Indicates the type of sub-board on the board where a remote NO maintenance channel is established.

YES

No

LBFD-004002 / TDLBFD-004002

Indicates the local IPv6 address of a remote maintenance channel. This address must be a global unicast address. Indicates the peer IPv6 address of a remote maintenance channel. This address must be a global unicast address.

YES

YES

No

LBFD-003006 / TDLBFD-003006 LBFD-004002 / TDLBFD-004002

NO

YES

No

LBFD-003006 / TDLBFD-003006 LBFD-004002 / TDLBFD-004002

Indicates the status of an IPv6 remote NO maintenance channel.

NO

Yes

LBFD-003006 / TDLBFD-003006 LBFD-004002 / TDLBFD-004002

Indicates the cabinet number of the board where the YES packet filtering is used.

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the subrack number of the board where the YES packet filtering is used.

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the slot number of the board YES where the packet filtering is used.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the type of YES the port.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the port number.

YES

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the ID of an advanced ACL. The value of this NO parameter ranges from 3000 to 3999. Indicates whether to permit or reject access of the data that does not match the ACL rule. If this parameter is set to PERMIT, data that does not match the NO ACL rule is allowed to pass. If this parameter is set to DENY, data that does not match the ACL rule is discarded.

YES

No

LOFD-003014 / TDLOFD-003014

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the type of sub-board on the YES board where packet filter is enabled.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the number of transmitted packets. NO This parameter is reserved for further extension. Indicates the number of received NO packets.

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the number of permitted packets on the TX channel. This NO parameter is reserved for further extension. Indicates the number of permitted NO packets on the RX channel. Indicates the number of rejected packets on the TX channel. This NO parameter is reserved for further extension. Indicates the number of rejected packets on the RX channel.

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the number of bytes contained in transmitted packets. NO This parameter is reserved for further extension. Indicates the number of bytes contained in received packets.

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the number of bytes contained in permitted packets NO on the TX channel. This parameter is reserved for further extension. Indicates the number of bytes contained in NO permitted packets on the RX channel.

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the number of bytes contained in rejected packets on NO the TX channel. This parameter is reserved for further extension. Indicates the number of bytes contained in NO rejected packets on the RX channel. Indicates the number of bytes contained in the packets that do not match the ACL rules for packet filtering. If MB is set to PERMIT, this parameter measures the number of bytes contained in the NO accessed packets. If MB is set to DENY, this parameter measures the number of bytes contained in the discarded packets. This parameter is valid only when CATALOG is set to PORT.

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

NO

Yes

LOFD-003014 / TDLOFD-003014

Indicates the number of the packets that do not match the ACL rules for packet filtering. If MB is set to PERMIT, this parameter measures the number of accessed NO packets. If MB is set to DENY, this parameter measures the number of discarded packets. This parameter is valid only when CATALOG is set to PORT. Indicates the ID of an ACL at layer 2. The value of this parameter ranges NO from 4000 to 4999. The BS filters packets based on only VLAN IDs. Indicates the packet filtering mode. The BS can filter packets based on NO the advanced ACL, layer-2 ACL, or both at the same time. Indicates the destination IP address in a ping filter entry. This address must be a valid IP address of class A, B, or C. It can also be a network segment address.

NO

Yes

LOFD-003014 / TDLOFD-003014

YES

No

LOFD-003014 / TDLOFD-003014

NO

No

LOFD-003014 / TDLOFD-003014

YES

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the subnet mask corresponding to the IP address in YES a ping filter entry. The subnet mask cannot be 0.0.0.0.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the PMTU detection mode: active or passive. When this parameter is set to ACTIVE, PMTU detection is periodically performed. When NO this parameter is set to PASSIVE, the PMTU is adjusted according to the ultra-large Internet Control Message Protocol (ICMP) messages received. Indicates the destination port number of the UDP packets for PMTU detection. Ports 65020, 65010, 65099, and 65100 NO are used for IP PM, FPMUX, and AACP, and therefore these ports should not be used for PMTU detection. Indicates the timeout duration of a single PMTU detection.

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LBFD-003006 / TDLBFD-003006

NO

NO

No

LBFD-003006 / TDLBFD-003006

Indicates the aging period of the PMTU NO table.

NO

No

LBFD-003006 / TDLBFD-003006

Indicates the default DSCP. If no DSCP is specified for a link, the default NO DSCP is used when a PMTU detection is performed on the link. Indicates the number of the cabinet that houses YES the board where port security is enabled. Indicates the number of the subrack that houses YES the board where port security is enabled. Indicates the number of the slot corresponding to the board where port security is enabled.

NO

No

LBFD-003006 / TDLBFD-003006

NO

No

LOFD-003014 / TDLOFD-003014

NO

No

LOFD-003014 / TDLOFD-003014

YES

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the type of sub-board on the YES board where port security is enabled.

YES

No

LOFD-003014 / TDLOFD-003014

Indicates the type of port on which port YES security is enabled.

NO

No

LOFD-003014 / TDLOFD-003014

Indicates the number of the port on which port security is configured.

YES

YES

No

LOFD-003014 / TDLOFD-003014

Indicates whether to disable services on a specified port to implement port security. If this parameter is set to NO DISABLE, running services on the port is prohibited, thereby guaranteeing the security of the port. Indicates the cabinet number of YES the board where the PPP link is located.

NO

No

LOFD-003014 / TDLOFD-003014

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the subrack number of YES the board where the PPP link is located. Indicates the slot number of the board YES where the PPP link is located.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

YES

No

Indicates the number of the PPP YES link.

YES

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the number of the ET/T1 port that carries the PPP link.

NO

YES

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the mode in which the local end of a PPP link authenticates the peer end. The authentication mode is classified into NONAUTH, PAP, and CHAP. In PAP mode, user names and passwords are transmitted explicitly on the network. If they are intercepted during transmission, a great threat to network security is NO caused. Thus, the PAP is applied only to the network environment with low security requirements. With three handshakes, the CHAP provides a more secure authentication. In CHAP mode, only user accounts rather than passwords are transmitted, enhancing security compared to the Indicates the authentication user NO name of the PPP link. Indicates the password for authenticating a PPP link.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

YES

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

YES

No

Indicates the number of the ET/T1 timeslot that carries the PPP link. Timeslot 0 is used for synchronization, and cannot be configured. In E1 NO mode, timeslots 1 to 31 can be configured. In T1 mode, only timeslots 1 to 24 can be configured. Other timeslots are not used.

YES

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the local IP address. If this parameter is set to NO 0.0.0.0, this parameter needs to be negotiated.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the subnet mask of the local IP address. If this NO parameter is set to 0.0.0.0, it needs to be negotiated.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the peer IP address. If the BS is connected to an upper-level node, this address is specified according to the NO upper-level node. If the BS is cascaded to a lower-level node, this address must be specified. This parameter can be set to 0.0.0.0.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates whether to enable the PPP multiframe multiplexing function. If this parameter is set to NO ENABLE, multiple PPP frames are multiplexed on the PPP link to reduce the bandwidth overhead.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the maximum length of the PPP NO Multiplexing (MUX) subframe.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the maximum length of NO the PPP MUX frame.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the timeout duration of the PPP MUX combination.

NO

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates whether to enable IP header NO compression.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the Maximum Receive Unit (MRU). If the size of a received NO packet is greater than the MRU value, the packet is discarded. Indicates whether to enable protocol field NO compression.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates whether to enable the compression of the NO address field and control field.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the timeout duration for NO the PPP link negotiation. Indicates the status NO of the PPP link.

NO

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

Yes

Indicates the status of the Link Control NO Protocol (LCP) protocol.

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the status of the IP Control NO Protocol (IPCP).

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the status NO of the PPP MUX.

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the local IP address negotiated with the peer end. Indicates the mask of the local IP address that is negotiated with the peer end. Indicates the peer IP address negotiated with the peer end.

NO

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

NO

Yes

NO

NO

Yes

Indicates the negotiation result of NO the IP header compression. Indicates the negotiation result of the compression NO switch of the address field and control field. Indicates the negotiation result of the compression NO switch of the protocol field. Indicates the negotiation result of NO the maximum RX unit.

NO

Yes

NO

Yes

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

Yes

Indicates the negotiation result of NO the PPP MUX. Indicates the number of packets received on the PPP link. Indicates the number of packets transmitted on the PPP link. Indicates the RX traffic of the PPP link. Indicates the TX traffic of the PPP link. Indicates the number of IP addresses of the PPP link.

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

Indicates the list of IP addresses of the NO PPP link. Indicates the PPP frame error rate threshold above NO which the related alarm is generated. Indicates the PPP frame error rate threshold below which the related alarm is cleared.

NO

Yes

NO

No

NO

NO

No

Indicates the type of sub-board on the YES board where a PPP link is located.

YES

No

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

Indicates the number of bytes received on the PPP link. Indicates the number of discarded packets received on the PPP link. Indicates the number of bytes transmitted on the PPP link. Indicates the number of discarded packets transmitted on the PPP link.

NO

NO

Yes

LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402 LBFD-003004 / TDLBFD-003004 LBFD-00300402 / TDLBFD-00300402

NO

NO

Yes

NO

NO

Yes

NO

NO

Yes

Indicates the lowest priority of queue 0. If the Differentiated Services Code Point (DSCP) value of a service packet NO is greater than or equal to this parameter value, the service packet is assigned to queue 0.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the lowest priority of queue 1. If the DSCP value of a service packet is smaller than the PRI0 value but NO greater than or equal to this parameter value, the service packet is assigned to queue 1.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the lowest priority of queue 2. If the DSCP value of a service packet is smaller than the PRI1 value but NO greater than or equal to this parameter value, the service packet is assigned to queue 2.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the lowest priority of queue 3. If the DSCP value of a service packet is smaller than the PRI2 value but NO greater than or equal to this parameter value, the service packet is assigned to queue 3.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the lowest priority of queue 4. If the DSCP value of a service packet is smaller than the PRI3 value but NO greater than or equal to this parameter value, the service packet is assigned to queue 4.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the lowest priority of queue 5. If the DSCP value of a service packet is smaller than the PRI4 value but NO greater than or equal to this parameter value, the service packet is assigned to queue 5.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the lowest priority of queue 6. If the DSCP value of a service packet is smaller than the PRI5 value but NO greater than or equal to this parameter value, the service packet is assigned to queue 6.

NO

No

LBFD-00300201 / TDLBFD-00300201

Indicates the number of the cabinet that houses the board where a YES transmission resource group is established. Indicates the number of the subrack that houses the board where a YES transmission resource group is established. Indicates the number of the slot corresponding to the board where a transmission resource group is established.

NO

No

LOFD-003011 / TDLOFD-003011

NO

No

LOFD-003011 / TDLOFD-003011

YES

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the bearer type of a YES transmission resource group.

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the type of sub-board on the board where a YES transmission resource group is established.

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the type of port where a transmission YES resource group is carried.

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the number of the port where a transmission resource group is carried.

YES

NO

No

LOFD-003011 / TDLOFD-003011

Indicates the ID of a transmission YES resource group.

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the rate unit of the TX bandwidth, RX bandwidth, TX CIR, NO RX CIR, TX PIR and RX PIR of the transmission resource group.

NO

No

LOFD-003011 / TDLOFD-003011

Indicates the maximum uplink bandwidth of a transmission resource group at the MAC layer when the transmission resource group is NO carried over IP. This parameter value is used as the uplink transport admission bandwidth and TX traffic shaping bandwidth.

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the RX bandwidth of a transmission resource group.

NO

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the TX committed burst size of a transmission resource group.

NO

NO

No

LOFD-003011 / TDLOFD-003011

Indicates the TX excessive burst size NO of a transmission resource group.

NO

No

LOFD-003011 / TDLOFD-003011

Indicates the index of the operator. This parameter is used to differentiate between operators. NO This parameter is reserved for future extension and does not take effect currently.

NO

No

LOFD-003011 / TDLOFD-003011

Indicates the scheduling weight of a transmission resource group. This parameter is used in calculating NO the bandwidth scheduled to a resource group, which helps achieve the user admission control.

NO

No

LOFD-003011 / TDLOFD-003011

Indicates the transmit CIR of the transmission resource group.

NO

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the receive CIR of the transmission resource group.

NO

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the transmit PIR of the transmission resource group.

NO

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the receive PIR of the transmission resource group.

NO

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the size of the peak burst transmitted from the NO transmission resource group.

YES

No

LOFD-003011 / TDLOFD-003011

Indicates the local real-time traffic that is transmitted in a transmission resource group. The local traffic includes NO only the local traffic stream exclusive of the passing-by data flow and non-traffic stream. Indicates the local real-time traffic that is received in a transmission resource group. The local traffic includes NO only the local traffic stream exclusive of the passing-by data flow and non-traffic stream.

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

Yes

LOFD-003011 / TDLOFD-003011

Indicates the local non-real-time traffic that is transmitted in a transmission resource group. The local traffic includes NO only the local traffic stream exclusive of the passing-by data flow and non-traffic stream. Indicates the local non-real-time traffic that is received in a transmission resource group. The local traffic includes NO only the local traffic stream exclusive of the passing-by data flow and non-traffic stream. Indicates the TX bandwidth reserved for non-real-time NO services in a transmission resource group. Indicates the RX bandwidth reserved for non-real-time NO services in a transmission resource group. Indicates the GBR service traffic that is transmitted by the NO transmission resource group. Indicates the GBR service traffic received by the transmission resource group.

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

NO

Yes

LOFD-003011 / TDLOFD-003011

Indicates the rate configuration mode NO of the transmission resource group. Indicates the uplink admission bandwidth of the NO transmission resource group.

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

Yes

LOFD-003011 / TDLOFD-003011

Indicates the downlink admission bandwidth of the NO transmission resource group. Indicates the UL Committed Information Rate (CIR) admission bandwidth for the transmission resource group. Indicates the CIR admission bandwidth of the transmission resource group in DL. Indicates the UL PIR admission bandwidth of the transmission resource group. Indicates the PIR admission bandwidth of the transmission resource group in DL.

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

NO

Yes

LOFD-003011 / TDLOFD-003011

Indicates the realtime traffic sent NO on a transmission resource group. Indicates the number of the cabinet that houses the board where a YES transmission resource group is established. Indicates the number of the subrack that houses the board where a YES transmission resource group is established.

NO

Yes

LOFD-003011 / TDLOFD-003011

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the number of the slot corresponding to the board where a transmission resource group is occupied.

YES

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the type of sub-board on the board where a YES transmission resource group is established.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the type of port on which a transmission YES resource group is carried.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the number of the port on which a transmission resource group is carried.

YES

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the ID of a transmission YES resource group.

YES

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates whether to enable traffic shaping for a transmission resource group. If this parameter is set to ON, traffic shaping is performed according to the TX bandwidth so that the transmit traffic would not exceed NO the capability of downstream routers, thus avoiding unnecessary packet loss and congestion. If this parameter is set to OFF, traffic shaping is not performed during data transmission.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates whether to enable the dynamic adjustment of the RX bandwidth of a transmission resource group. If this parameter is set to ON, the TX bandwidth is adjusted according to the network performance and dynamic bandwidth adjustment parameters (down speed PLR NO threshold and down speed delay threshold). The network performance is monitored through IP PM sessions, which can be enabled at the local end or at the peer end. If this parameter is set to OFF, the TX bandwidth is not adjusted.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates whether to enable the dynamic adjustment of the RX bandwidth of a transmission resource group. If this parameter is set to ON, the RX bandwidth is adjusted according to the network performance and dynamic bandwidth adjustment parameters (down speed PLR NO threshold and down speed delay threshold). The network performance is monitored through IP PM sessions, which can be enabled at the local end or at the peer end. If this parameter is set to OFF, the RX bandwidth is not adjusted.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the rate downsizing packet loss rate threshold for bandwidth adjustment. When RXBWASW or TXBWASW is set to ON, the estimated available transport bandwidth is reduced if the packet loss rate NO detected through IP Performance Monitoring (IP PM) is higher than this threshold. If the packet loss rate detected through IP PM is lower than this threshold, the estimated available transport bandwidth is increased.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the threshold for delay variation due to rate reduction. When RXBWASW or TXBWASW is set to ON, the estimated NO available transport bandwidth is reduced if the delay variation detected by an IP PM session is above this threshold.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the minimum TX bandwidth that adjustments can achieve. If the RATECFGTYPE (global rate configuration type) and TXBWASW (TX bandwidth adjustment switch) NO parameters are set to SINGLE_RATE and ON, respectively, the TX bandwidth obtained after each adjustment is equal to or larger than the value of this parameter. Indicates the minimum RX bandwidth that adjustments can achieve. If the RATECFGTYPE (global rate configuration type) and RXBWASW (RX bandwidth adjustment switch) NO parameters are set to SINGLE_RATE and ON, respectively, the RX bandwidth obtained after each adjustment is equal to or larger than the value of this parameter.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates whether to enable the backpressure algorithm of a transmission resource group. The BS monitors the data buffered in the queues of each transmission resource group, determines whether the transmission resource group is congested, and transmits the backpressure NO signals (number and congestion status of the transmission resource group) to each flow control service. If the number of data packets in the buffer of any backpressure queue exceeds 75% of the queue capacity, the BS regards this transmission resource group as

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates whether backpressure is performed on the OM FTP queue in a transmission resource group. If this parameter is set to ENABLE, the OM FTP queue participates the decision of the congestion status of the transmission resource group, and the OM low-level upload and download data NO preempts the bandwidth of nonreal-time services. If this parameter is set to DISABLE, the OM FTP queue does not participate the decision of the congestion status of the transmission resource group, and the OM low-level upload and download data does not preempt the bandwidth of nonreal-time services.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the number of Priority Queues (PQs) in a transmission resource group. The queues in a transmission resource group are classified into PQs and non-PQs. The scheduling priority of any PQ is higher than that of any nonPQ. There is no Priority Queues when this parameter value is 0.The NO queues numbered from 0 to the result after this parameter value minus 1 are PQs. PQ scheduling is used between PQs. A smaller PQ number indicates a higher scheduling priority. The queues numbered from this parameter value to 6 are non-PQs. Weight Round Robin (WPR) scheduling is used between non-PQs. Indicates the congestion time threshold of a transmission resource group. When TCSW is set to ENABLE, if the buffer time of nonreal-time service data in a transmission NO resource group exceeds the threshold, it indicates that the transmission resource group is congested and the backpressure signals are transmitted.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the congestion clear time threshold of a transmission resource group. When TCSW is set to ENABLE, if the buffer time of nonreal-time service data in a transmission NO resource group is below the threshold, it indicates that the transmission resource group is not congested and therefore the congestion clear signals are transmitted.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the TX bandwidth reserved for signaling or OM data. This parameter should be set to a value smaller than the TX bandwidth of a transmission NO resource group. The recommended reserved TX bandwidth is lower than or equal to 3% of the TX bandwidth of a transmission resource group.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the reserved RX bandwidth, which should be set to a value smaller than or equal to the RX bandwidth of a transmission resource group.

NO

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the number threshold of discarded packets. This parameter indicates the capability of the queue in a transmission resource group to buffer packets. A greater parameter value indicates a stronger capability. If this parameter is set to 0, the queue in a transmission resource group NO cannot buffer packets, and thus all the delayed packets on the TX channel are discarded. The number threshold of discarded packets determines the maximum amount of data that can be buffered in a transmission resource group. The congestion time threshold of a transmission

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301102 / TDLOFD-00301102 LOFD-00301103 / TDLOFD-00301103

Indicates the number of the SCTP link.

YES

YES

No

None

Indicates the cabinet number of the SCTP link. Indicates the subrack number of the SCTP link. Indicates the slot number of the SCTP link. Indicates the maximum stream number of the SCTP link.

NO

NO

No

None

NO

NO

No

None

NO

YES

No

None

NO

NO

No

None

Indicates the first local IP address of the SCTP link.

NO

YES

No

None

Indicates the second local IP address of the SCTP link.

NO

NO

No

None

Indicates the local port number of the SCTP link.

NO

YES

No

None

Indicates the first peer IP address of the SCTP link.

NO

YES

No

None

Indicates the second peer IP address of the SCTP link.

NO

NO

No

None

Indicates the peer port number of the SCTP link.

NO

YES

No

None

Indicates the minimum Retransmission Timeout (RTO) value for the SCTP link. A smaller value of this parameter indicates a shorter time required to check link connectivity. The NO time required to check link connectivity is twice the sum of the new RTO and heartbeat interval. The new RTO ranges from the minimum RTO value to maximum RTO value.

NO

No

None

Indicates the maximum RTO value of an SCTP link. A larger value indicates a longer period required for checking link connectivity.

NO

NO

No

None

Indicates the initial RTO value of an SCTP link. A larger value indicates a NO longer period required for checking link connectivity. Indicates the RTO alpha value of an SCTP link. This parameter computes the value of the Smoothed Round-Trip Time (SRTT) for a specific destination address; A larger value of this parameter indicates a higher importance to the last RTT measurement. For definitions of the alpha value, see NO RFC4960. RTO Calculation: The rules governing the computation of SRTT, RTTVAR, and RTO are as follows: 1) Until an RTT measurement has been made for a packet sent to the given destination transport address, set RTO to the protocol parameter 'RTO.Initial'. 2) When the first

NO

No

None

NO

No

None

Indicates the RTO beta value of an SCTP link. This parameter computes the value of the Smoothed Round-Trip Time (SRTT) for a specific destination address; A larger value of this parameter indicates a higher importance to the last RTT measurement. For definitions of the beta value, see NO RFC4960. RTO Calculation: The rules governing the computation of SRTT, RTTVAR, and RTO are as follows: 1) Until an RTT measurement has been made for a packet sent to the given destination transport address, set RTO to the protocol parameter 'RTO.Initial'. 2) When the first

NO

No

None

Indicates the heartbeat interval for an SCTP link. The heartbeat check is independently initiated by each end of an association and then confirmed by the peer end through the HB ACK packet. When no services are NO carried, a link disconnection is determined if the number of heartbeat check attempts reaches the maximum retransmission attempts on an association but the HB ACK packet is not received from the peer end. Indicates the maximum number of retransmissions for the SCTP association. When the number of retransmissions for NO the association exceeds the value of this parameter, the SCTP link is broken and a link failure alarm is reported.

NO

No

None

NO

No

None

Indicates the maximum number of retransmissions over a path. When the number of retransmissions over a path exceeds the value of this parameter, the path NO is regarded as failed if no heartbeat acknowledgment is received. If multiple paths are used, path switching is automatically performed. Indicates whether to calculate the checksum of the data to be sent. This parameter will be removed in later versions. In this version, the setting of this parameter is NO still synchronized between the M2000 and the BS, but it is always set to ENABLE internally. Therefore, avoid setting this parameter to DISABLE.

NO

No

None

NO

No

None

Indicates whether to check the checksum of the packet that is received. This parameter will be removed in later versions. In this version, the setting of this parameter is NO still synchronized between the M2000 and the BS, but it is always set to ENABLE internally. Therefore, avoid setting this parameter to DISABLE. Indicates the checksum algorithm.

NO

No

None

NO

NO

No

None

Indicates whether to switch back to the primary path when it is restored. The SCTP link switches to the secondary path when the primary path cannot be reached. If this parameter is set to ENABLE, the SCTP NO link switches to the primary path when the primary path is restored. If this parameter is set to DISABLE, the SCTP link does not switch to the primary path when the primary path is restored.

NO

No

None

Indicates the number of heartbeats to be detected before the transmission switches back to the primary path. After the primary path is NO restored, the transmission switches back to the primary path when the number of heartbeats detected reaches this value.

NO

No

None

Indicates the status NO of the SCTP link.

NO

Yes

None

Indicates the cause of the latest change that the operational state of the SCTP NO link transits from available to unavailable.

NO

Yes

None

Indicates the time of the latest change that the operational state of the SCTP NO link transits from available to unavailable.

NO

Yes

None

Indicates the number of outbound NO streams negotiated for the SCTP link. Indicates the number of inbound NO streams negotiated for the SCTP link. Indicates the working address flag of the SCTP link. Indicates whether the SCTP link is blocked or not. NO

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

No

None

Indicates the time interval that one end of an SCTP link has to wait before it can send an SACK message in response to the reception of data. A NO larger value of this parameter indicates a longer time interval between the reception of data and the sending of the corresponding SACK message. Indicates the peer description information of the SCTP link.

NO

No

None

NO

NO

No

None

Indicates the number of an IPv6 SCTP link.

YES

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the number of streams supported NO simultaneously by an IPv6 SCTP link.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the first local IPv6 address of an IPv6 SCTP link.

NO

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the second local IPv6 address of an IPv6 SCTP link.

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the local SCTP port number of the IPv6 SCTP link. This parameter must be set to the same value as that NO of the peer SCTP port number in the IPv6 SCTP link configured at the peer end.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the first peer IPv6 address of an IPv6 SCTP link.

NO

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the second peer IPv6 address of an IPv6 SCTP link.

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the peer SCTP port number of the IPv6 SCTP link. This parameter must be set to the same value as that NO of the local SCTP port number in the IPv6 SCTP link configured at the peer end.

YES

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the minimum Retransmission Timeout (RTO) value for the SCTP IPv6 link. A smaller NO value of this parameter indicates a shorter time required to check link connectivity. Indicates the maximum RTO value of an IPv6 SCTP link. A larger value indicates a NO longer period required for checking link connectivity. Indicates the initial RTO value of an IPv6 SCTP link. A larger value indicates a longer period required for checking link connectivity.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the RTO alpha value of an IPv6 SCTP link. A larger value NO indicates less sensitivity to the link delay. For details, see RFC4960. Indicates the RTO beta value of an IPv6 SCTP link. A larger value NO indicates less sensitivity to the link delay. For details, see RFC4960.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the heartbeat interval for an IPv6 SCTP link. The heartbeat check is independently initiated by each end of an association and then confirmed by the peer end through the HB ACK packet indicating normal NO link connection. If the number of heartbeat check attempts reaches the maximum retransmission attempts on an association but the HB ACK packet is not received from the peer end, a link disconnection is determined. Indicates the maximum number of association retransmissions on the IPv6 SCTP link. If the number of retransmissions NO exceeds the value of this parameter, the SCTP link is broken and a link failure alarm is reported.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the maximum number of retransmissions over a path of the IPv6 SCTP link. If no heartbeat response is received when the number of retransmissions over a path exceeds NO the value of this parameter, it indicates that the current path cannot be reached. If multiple paths are used on the IPv6 SCTP link, path switching is performed. Indicates the checksum arithmetic.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates whether to switch back to the primary path when the primary path is restored. The IPv6 SCTP link switches to the secondary path when the primary path cannot NO be reached. This parameter is used to set whether an IPv6 SCTP link switches back to the primary path when the primary path is restored.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the number of heartbeats that are detected before transmission smoothly switches back from the associated secondary path to the primary path. After the associated primary path is NO restored, transmission smoothly switches back from the secondary path to the primary path when the number of detected successive heartbeats reaches this parameter value.

NO

No

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the status of the IPv6 SCTP NO link.

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the cause of the latest change of the operational state of an IPv6 NO SCTP link from available to unavailable.

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

Indicates the last time when the operational state of an IPv6 SCTP link NO changes from available to unavailable. Indicates the number of TX streams negotiated NO for an IPv6 SCTP link. Indicates the number of RX streams negotiated NO for an IPv6 SCTP link. Indicates the working address flag of an IPv6 SCTP link. NO

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

Yes

LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017 LBFD-003006 / TDLBFD-003006 LOFD-003017 / TDLOFD-003017

NO

Yes

NO

Yes

Indicates whether the IPv6 SCTP link NO is blocked. Indicates the peer description information of an IPv6 SCTP link.

NO

No

NO

NO

No

Indicates the source or destination IP YES address used for mapping the VLAN.

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the subnet mask of the source or destination IP YES address used for mapping the VLAN.

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the VLAN NO ID in the VLAN tag.

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the switch that is used to control whether to NO apply UL admission control to a resource group.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to NO apply DL admission control to a resource group.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the activity factor of the service data with QoS Class Indicator (QCI) of 1. The activity factor must NO be set for the service with each QCI, because services of different QCIs experience different loads.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 2.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 3.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 4.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 5.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 6.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 7.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 8.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the activity factor of the service NO data of QCI 9.

NO

No

LOFD-00301101 / TDLOFD-00301101 LOFD-00301103 / TDLOFD-00301103 LOFD-003016 / TDLOFD-003016 LOFD-001032 / TDLOFD-001032

Indicates the UL admission threshold for handed-over services. A large value of this NO parameter will result in a high UL admission success rate of handed-over services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the DL admission threshold for handed-over services. A large value of this NO parameter will result in a high DL admission success rate of handed-over services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the UL admission threshold for new Gold-level services. A large value of this NO parameter will result in a high UL admission success rate of new Goldlevel services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the DL admission threshold for new Gold-level services. A large value of this NO parameter will result in a high DL admission success rate of new Goldlevel services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the UL admission threshold for new Silver-level services. A large value of this NO parameter will result in a high UL admission success rate of new Silverlevel services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the DL admission threshold for new Silver-level services. A large value of this NO parameter will result in a high DL admission success rate of new Silverlevel services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the UL admission threshold for new Copperlevel services. A large value of this NO parameter will results in a high UL admission success rate of new Copperlevel services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the DL admission threshold for new Copperlevel services. A large value of this NO parameter will result in a high DL admission success rate of new Copperlevel services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the uplink transport admission threshold for the Guaranteed the Bit Rate (GBR) service. A large value of this NO parameter will result in a high UL admission success rate of GBR services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the DL admission threshold for the guaranteed bit rate (GBR) service. A large value of this NO parameter will result in a high DL admission success rate of GBR services.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to enable the UL preemption algorithm. If this parameter is set to ON, the UL pre-emption algorithm is enabled. In this case, the service with a higher priority that requests admission may preempt the resources of admitted services with lower priorities NO when UL transmission bandwidth is insufficient. If this parameter is set to OFF, the UL preemption algorithm is disabled. In this case, services with higher priorities that request admission cannot pre-empt the resources of admitted services with lower priorities when UL transmission

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to enable the DL preemption algorithm. If this parameter is set to ON, the DL pre-emption algorithm is enabled. In this case, the service with a higher priority that requests admission can preempt the resources of admitted services with lower priorities NO when DL transmission bandwidth is insufficient. If this parameter is set to OFF, the DL preemption algorithm is disabled. In this case, services with higher priorities that request admission cannot pre-empt the resources of admitted services with lower priorities when DL transmission

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to enable UL overbooking admission control. It NO is used to determine the admission bandwidth of the resource group and facilitate admission control.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to enable DL overbooking admission control. It NO is used to determine the admission bandwidth of the resource group and facilitate admission control.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to apply UL admission control to a physical port. If this parameter is set to ON, UL admission NO control is applied to the physical port. If this parameter is set to OFF, UL admission control is not applied to the physical port.

NO

No

LOFD-00301101 / TDLOFD-00301101

Indicates the switch that is used to control whether to apply DL admission control to a physical port. If this parameter is set to ON, DL admission NO control is applied to the physical port. If this parameter is set to OFF, DL admission control is not applied to the physical port. Indicates the threshold for triggering the UL high load. If the ratio of the UL transport load to the UL transport bandwidth of the BS keeps above this threshold for a period of hysteresis, the UL transport NO load of the BS enters the high-load state. In UL highload state, the BS sends a UL S1 TNL Load Indicator, which is set to HighLoad, to each neighboring BS through the X2 interface.

NO

No

LOFD-00301101 / TDLOFD-00301101

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the threshold for triggering the DL high load. If the ratio of the DL transport load to the DL transport bandwidth of the BS keeps above this threshold for a period of hysteresis, the DL transport NO load of the BS enters the high-load state. In DL highload state, the BS sends a DL S1 TNL Load Indicator, which is set to HighLoad, to each neighboring BS through the X2 interface. Indicates the threshold for clearing the UL high load. If the ratio of the UL transport load to the UL transport bandwidth of the BS keeps below this threshold for a period of hysteresis, the UL NO transport load of the BS enters the medium-load state. In UL medium load state, the BS sends a UL S1 TNL Load Indicator, which is set to MediumLoad, to each neighboring BS through the X2 interface.

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the threshold for clearing the DL high load. If the ratio of the transport load to the transmission bandwidth in DL of the BS keeps below this threshold for a period of time, the DL transport load of NO the BS enters the medium-load state. In DL medium-load state, the BS sends a DL S1 TNL Load Indicator, which is set to MediumLoad, to each neighboring BS through the X2 interface. Indicates the threshold for triggering the UL medium load. If the ratio of the UL transport load to the UL transport bandwidth of the BS is above this threshold, the UL transport load of the NO BS enters the medium-load state. In UL medium-load state, the BS sends a UL S1 TNL Load Indicator, which is set to MediumLoad, to each neighboring BS through the X2 interface.

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the threshold for triggering the DL medium load. If the ratio of the DL transport load to the DL transport bandwidth of the BS is above this threshold, the DL transport load of the NO BS enters the medium-load state. In DL medium-load state, the BS sends a DL S1 TNL Load Indicator, which is set to MediumLoad, to each neighboring BS through the X2 interface. Indicates the threshold for clearing the UL medium load. If the ratio of the UL transport load to the UL transport bandwidth of the BS is below this threshold, the UL transport load of the NO BS enters the lowload state. In UL low-load state, the BS sends a UL S1 TNL Load Indicator, which is set to LowLoad, to each neighboring BS through the X2 interface.

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

LOFD-001032 / TDLOFD-001032

Indicates the threshold for clearing the DL medium load. If the ratio of the DL transport load to the DL transport bandwidth of the BS is below this threshold, the DL transport load of the NO BS enters the lowload state. In DL low-load state, the BS sends a DL S1 TNL Load Indicator, which is set to LowLoad, to each neighboring BS through the X2 interface. Indicates whether to enable the function of clearing faults on a transmission link. If this parameter is set to ENABLE, the system automatically detects a faulty transmission link. If NO the BS cannot be maintained due to a faulty link and services are disrupted for a certain period of time, automatic reset of the BS is performed to clear the faults.

NO

No

LOFD-001032 / TDLOFD-001032

NO

No

None

Indicates the UL Over Load Control (OLC) algorithm switch. In the case of enabled switch, the bandwidth of the services with low priority would be released to NO guarantee the QoS of the services of high priority when the TX bandwidth changes or during the overload caused by real-time services.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the switch for the DL OLC algorithm. If this parameter is set to ON, bandwidth of the services of a low priority is released to guarantee the QoS NO of the services of a high priority when transport bandwidth changes or overload occurs due to increased load of non-flow control services.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the threshold for triggering the UL OLC. When the UL bandwidth occupancy reaches NO the threshold, lowpriority services are removed to guarantee the quality of highpriority services.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the threshold for clearing the UL OLC. When the UL bandwidth NO occupancy is below this threshold, user services are no longer removed.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the number of released NO services during an OLC action period.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the threshold for triggering the DL OLC. When the DL bandwidth occupancy reaches NO the threshold, lowpriority services are removed to guarantee the quality of highpriority services.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the threshold for clearing the DL OLC. When the DL bandwidth NO occupancy is below this threshold, user services are no longer removed.

NO

No

LOFD-00301103 / TDLOFD-00301103

Indicates the mode of the ping filtering. When the whitelist is used, only the network segments or hosts specified NO by the ping filter can ping the NE. When the blacklist is used, the network segments or hosts. Indicates the number of packets discarded due to fragmentation failures on the transmitter.

NO

No

None

NO

NO

Yes

None

Indicates the number of received NO packets that have been encrypted. Indicates the number of packets that have been successfully decrypted at the receiver.

NO

Yes

None

NO

NO

Yes

None

Indicates the number of received packets that fail the NO ESP-based decryption.

NO

Yes

None

Indicates the number of received packets that fail the NO AH-based authentication. Indicates the number of received packets that should NO not have been encrypted. Indicates the total number of packets received by the decryption module of the receiver at the IP layer.

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the total number of packets that fail decryption NO at the IP layer of the receiver. Indicates the number of received NO IKE packets. Indicates the number of encrypted packets received by the IP NO layer of the receiver from invalid IP addresses. Indicates the total number of packets discarded at the IP NO layer of the receiver due to replay attacks. Indicates the total number of packets discarded at the IP NO layer of the receiver due to a lack of inbound SA. Indicates the total number of packets discarded because the IP layer of the NO receiver does not support the AH algorithm.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

Yes

None

Indicates the total number of packets discarded because the IP layer of the NO receiver does not support the ESP algorithm. Indicates the total number of plain packets received at NO the IP layer of the receiver. Indicates the number of packets received at the IP layer that comply with ACL rules and should have been encrypted.

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the number of transmitted packets NO that are successfully encrypted. Indicates the number of packets that fail to be encrypted at the transmitter.

NO

Yes

None

NO

NO

Yes

None

Indicates the total number of received NO packets. Indicates the number of packets that need to be encrypted at the transmitter.

NO

Yes

None

NO

NO

Yes

None

Indicates the number of packets discarded at the NO transmitter because the outbound SAs do not exist. Indicates the number of packets discarded because NO the transmitter does not support the AH algorithm.

NO

Yes

None

NO

Yes

None

Indicates the number of packets discarded because NO the transmitter does not support the ESP algorithm. Indicates the number of packets that fail the AHNO based authentication at the transmitter. Indicates the number of transmitted packets NO that fail ESP encryption. Indicates the number of packets discarded due to transmitting sequence number overflow.

NO

Yes

None

NO

Yes

None

NO

Yes

None

NO

NO

Yes

None

Indicates the number of packets that do not need to NO be encrypted at the transmitter. Indicates the number of transmitted IKE packets. Indicates the number of the source cabinet where the tunnel is configured. Indicates the number of the source subrack where the tunnel is configured. Indicates the number of the source slot where the tunnel is configured.

NO

Yes

None

NO

NO

Yes

None

YES

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

YES

NO

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

YES

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the index of the tunnel.

YES

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the number of the destination cabinet where the tunnel is located.

NO

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the number of the destination subrack NO where the tunnel is located. Indicates the number of the destination slot where the tunnel is located.

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

NO

YES

No

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the number of bytes received through the tunnel.

NO

NO

Yes

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the actual number of packets NO received through a tunnel.

NO

Yes

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the actual number of bytes NO sent through the tunnel.

NO

Yes

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the actual number of packets NO sent through the tunnel.

NO

Yes

MRFD-231501 LOFD-003002 / TDLOFD-003002

Indicates the VLAN group that the added VLAN mapping belongs to. Multiple VLAN groups are used in YES the scenario in which telecom operators share transport resources and use different VLAN policies. Indicates the traffic type. Traffic of different types is transmitted through different VLANs. High-priority OM data includes the data of NTP/SNTP, remote maintenance channel switchover, and TCP (excluding YES that related to FTP). Low-priority OM data includes the data of the File Transfer Protocol (FTP) service. Other data refers to the data except the user data, signaling, high-priority OM data, and lowpriority OM data.

YES

No

LBFD-003003 / TDLBFD-003003

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the DSCP YES priority of user data.

NO

No

LBFD-003003 / TDLBFD-003003

Indicates the VLAN ID that the service NO data belongs to. Indicates the VLAN priority. A greater parameter value NO denotes a higher priority.

YES

No

LBFD-003003 / TDLBFD-003003

NO

No

LBFD-003003 / TDLBFD-003003

Indicates the next hop IP address used for mapping the VLAN.

YES

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the subnet mask of the next hop IP address YES used for mapping the VLAN.

NO

No

LBFD-003003 / TDLBFD-003003

Indicates the VLAN mode. When this parameter is set to SINGLEVLAN, the configured VLAN ID and VLAN priority can be directly used to label the VLAN tag. If this parameter is set to VLANGROUP, the next hop IP addresses are mapped to the VLAN groups, and NO then mapped to the VLAN tags in the VLAN groups according to the DSCPs of the IP packets. In VLAN group mode, ensure that the VLAN groups have been configured by running the ADD VLANCLASS command. Otherwise, the configuration does not take effect.

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the VLAN NO ID in the VLAN tag.

YES

No

LBFD-003003 / TDLBFD-003003

Indicates the VLAN NO priority.

NO

No

LBFD-003003 / TDLBFD-003003

Indicates the VLAN NO group number.

YES

No

LBFD-003003 / TDLBFD-003003

Indicates whether to set the priority of a single VLAN. If a special VLAN mapping is not required, it is recommended that the parameter be set to DISABLE. In this case, the default VLAN mapping is used. The following describes the default mapping between DSCPs and priorities: NO If the DSCP is within the range from 0 to 7, the default priority is 0; If the DSCP is within the range from 8 to 15, the default priority is 1; If the DSCP is within the range from 16 to 23, the default priority is 2; If the DSCP is within the range from 24 to 31, the default priority is 3; If the DSCP is

NO

No

LBFD-003003 / TDLBFD-003003

Indicates the maximum wait time for an echo response. If no echo response is NO received during the period specified by this parameter, the timer has expired.

NO

No

None

Indicates the maximum number of timeouts of the echo response waiting timer. If no echo response is NO received after the number specified by this parameter is reached, the GTP-U path in use fails.

NO

No

None

Indicates the Differentiated Services Code Point (DSCP) of a GTP-U control packet.

NO

NO

No

None

Indicates whether to enable static detection in compliance with GPRS Tunneling Protocol for User Plane (GTP-U). If this parameter is set to ENABLE, the GTP-U static check NO is enabled. In this case, the ALM25886 IP Path Fault alarm is reported if a link bearing an IP path is faulty. If this parameter is set to DISABLE, the GTPU static check is disabled.

NO

No

None

Feature Name

Value Type

GUI Value Range

Enumeration Number/Bit

Unit

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Interval Type

0 N/A

None

Remote Electrical Tilt Control

Interval Type

60~254

N/A

None

Remote Electrical Tilt Control

Interval Type

0 N/A

None

Remote Electrical Tilt Control

Character String Type

0~128 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~15

N/A

degree

Remote Electrical Tilt Control

Interval Type

30,65,90,360

N/A

degree

Remote Electrical Tilt Control

Interval Type

33~64

N/A

None

Remote Electrical Tilt Control

Enumeration Type

INTELLIGENT, DISTRIBUTED

INTELLIGENT~1, DISTRIBUTED~2

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Enumeration Type

SINGLE, DUAL

SINGLE~1, DUAL~2 N/A

None

Interval Type

0~360

degree

Remote Electrical Tilt Control

Enumeration Type

FOURPORTS(Four Ports), FOURPORTS~0, EIGHTPORTS(Eigh EIGHTPORTS~1 t Ports)

None

Remote Electrical Tilt Control

Interval Type

0~100

N/A

0.01

Remote Electrical Tilt Control

Interval Type

-180~180

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~100

N/A

0.01

Remote Electrical Tilt Control

Interval Type

-180~180

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~100

N/A

0.01

Remote Electrical Tilt Control

Interval Type

-180~180

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~100

N/A

0.01

Remote Electrical Tilt Control

Interval Type

-180~180

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~100

N/A

0.01

Remote Electrical Tilt Control

Interval Type

-180~180

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~100

N/A

0.01

Remote Electrical Tilt Control

Interval Type

-180~180

N/A

degree

None

Interval Type

0~1048575

N/A

None

None

Character String Type

1~64 characters

N/A

None

None

Enumeration Type

DBS3900_LTE(DB S3900 LTE), BTS3900_LTE(BTS 3900 LTE), BTS3900A_LTE(BT S3900A LTE), BTS3900L_LTE(BT S3900L LTE), BTS3900AL_LTE(B TS3900AL LTE)

DBS3900_LTE~1, BTS3900_LTE~2, BTS3900A_LTE~3, None BTS3900L_LTE~4, BTS3900AL_LTE~5

Adaptive Power Consumption

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

Adaptive Power Consumption

Compound Type

22:00:00~5:00:00

N/A

None

Adaptive Power Consumption

Compound Type

23:00:00~6:00:00

N/A

None

None

Interval Type

180000000~180000 N/A 000

1e-6 degree

None

Interval Type

90000000~9000000 N/A 0

1e-6 degree

None

Character String Type

0~20 characters

N/A

None

None

Enumeration Type

Default, Normal, Demo, Protected, Emergency

Default~0, Normal~1, Demo~2, None Protected~3, Emergency~4

None

Enumeration Type

Poweroff(Power off), Normal

Poweroff~0, Normal~1

None

None

Character String Type

0~128 characters

N/A

None

None

Enumeration Type

DEG, SEC

DEG~0, SEC~1

None

None

Character String Type

0~16 characters

N/A

None

Character String Type

0~16 characters

N/A

None

Enumeration Type

CPRI, TDL_IR

CPRI~0, TDL_IR~1 None

None

Enumeration Type

Transmission_Pack et_Loss_Rate(Tran smission Packet Loss Rate), Transmission_Dela y(Transmission Delay), Transmission_Jitter( Transmission Jitter), Packet_Loss_Rate( Packet Loss Rate), Cell_RRC_Connect _Succ_Rate(Cell RRC Connect Succ Rate), Cell_ERAB_Setup_ Succ_Rate(Cell ERAB Setup Succ Rate), Cell_Call_Drop_Rat e(Cell Call Drop Rate), IntraFrequency_HO_Su cc_Rate(IntraFrequency HO Succ Rate), InterFrequency_HO_Su cc_Rate(Inter Frequency HO Succ Rate), LTECDMA_Handover_ Succ_Rate(LTECDMA Handover Succ Rate), LTE-

Transmission_Pack et_Loss_Rate~0, Transmission_Dela y~1, Transmission_Jitter ~2, Packet_Loss_Rate~ 3, Cell_RRC_Connect _Succ_Rate~4, Cell_ERAB_Setup_ Succ_Rate~5, Cell_Call_Drop_Rat None e~6, IntraFrequency_HO_Su cc_Rate~7, InterFrequency_HO_Su cc_Rate~8, LTECDMA_Handover_ Succ_Rate~9, LTEWCDMA_Handover _Succ_Rate~10, LTEGERAN_Handover _Succ_Rate~11

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Enumeration Type

15minutes(15minut es), 30minutes(30minut es), 60minutes(60minut es), 1day(1day 1440minutes)

15minutes~15, 30minutes~30, 60minutes~60, 1day~1440

min

None

Interval Type

0~23

N/A

None

Interval Type

1~3

N/A

None

None

Interval Type

0~17

N/A

None

None

Interval Type

180000000~180000 N/A 000

1e-6 degree

None

Interval Type

90000000~9000000 N/A 0

1e-6 degree

None

Enumeration Type

1T1R~0, 1T2R~1, 1T1R, 1T2R, 2T2R, 2T2R~3, 2T4R~4, 2T4R, 4T4R, 8T8R 4T4R~5, 8T8R~6

None

RRU Channel Cross Connection Under MIMO

Enumeration Type

NormalMIMO(Norm al MIMO), NormalMIMO~0, AIDMIMO(mutual- AIDMIMO~1 aid MIMO)

None

None

Enumeration Type

COMBTYPE_SING LE_RRU, COMBTYPE_TWO _RRU, COMBTYPE_THRE E_RRU, COMBTYPE_FOUR _RRU, COMBTYPE_FIVE_ RRU, COMBTYPE_SIX_ RRU, COMBTYPE_SEVE N_RRU, COMBTYPE_EIGH T_RRU

COMBTYPE_SING LE_RRU~0, COMBTYPE_TWO _RRU~1, COMBTYPE_THRE E_RRU~2, COMBTYPE_FOUR _RRU~3, None COMBTYPE_FIVE_ RRU~4, COMBTYPE_SIX_ RRU~5, COMBTYPE_SEVE N_RRU~6, COMBTYPE_EIGH T_RRU~7

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Character String Type

0~30 characters

N/A

None

None

Interval Type

-32767~32767

N/A

None

Interval Type

0~1800000

N/A

None

Interval Type

0~1800000

N/A

None

Interval Type

0~179

N/A

degree

None

Interval Type

0~990

N/A

None

Interval Type

0~100

N/A

None

Enumeration Type

DEG, SEC

DEG~0, SEC~1

None

None

Character String Type

0~16 characters

N/A

None

Character String Type

0~16 characters

N/A

None

Enumeration Type

FALSE, TRUE

FALSE~0, TRUE~1 None

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7, R1A~16, R1B~17, R2A~32, R2B~33, None R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113

None

Interval Type

0~500

N/A

0.1dBm

None

Enumeration Type

Normal, NoLicense

Normal~0, NoLicense~1

None

None

Character String Type

0~40 characters

N/A

0.1MHz

None

Character String Type

0~40 characters

N/A

0.1MHz

Remote Electrical Tilt Control

Enumeration Type

COMPATIBLE, HTTPS_ONLY, LOGIN_HTTPS_O NLY

COMPATIBLE~0, HTTPS_ONLY~1, LOGIN_HTTPS_O NLY~2

None

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Character String Type

0~2 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~36 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~49 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~62

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~254

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Enumeration Type

AISG1.1(AISG1.1), AISG2.0(AISG2.0), 3GPP(3GPP), UNKNOWN(NULL) 0~8

AISG1.1~1, AISG2.0~2, 3GPP~3, UNKNOWN~255 N/A

None

Interval Type

None

None

Character String Type

0~2 characters

N/A

None

None

Character String Type

0~36 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~19 characters

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Character String Type Character String Type

0~127 characters

N/A

None

0~19 characters

N/A

None

Remote Electrical Tilt Control

Enumeration Type

SINGLE_RET(SIN GLE_RET), SINGLE_RET~1, STMA(STMA), STMA~2, MULTI_RET(MULTI MULTI_RET~17 _RET) R0A(R0A), R0B(R0B), RET_PORT(RET_P ORT), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H), NULL(NULL)

None

None

Enumeration Type

R0A~0, R0B~1, RET_PORT~2, R0C~3, R0D~4, R0E~5, R0F~6, R0G~7, R0H~8, NULL~65535

None

Remote Electrical Tilt Control

Interval Type

0~62

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~254

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8

N/A

None

Remote Electrical Tilt Control

Enumeration Type

R0A(R0A), R0B(R0B), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H)

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7

None

Remote Electrical Tilt Control

Interval Type

0~1000

N/A

Remote Electrical Tilt Control

Interval Type

0~50

N/A

ns

Remote Electrical Tilt Control

Interval Type

0~50

N/A

ns

Remote Electrical Tilt Control

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

Remote Electrical Tilt Control

Enumeration Type

UER_SELF_DEFIN E(UER_SELF_DEF INE), TMA12DB_ONLY_ NON_AISG(TMA12 DB_ONLY_NON_AI SG), TMA24DB_ONLY_ NON_AISG(TMA24 DB_ONLY_NON_AI SG), RET_ONLY_COAXI AL(RET_ONLY_CO AXIAL), TMA12DB_AISG(T MA12DB_AISG), TMA24DB_AISG(T MA24DB_AISG)

UER_SELF_DEFIN E~0, TMA12DB_ONLY_ NON_AISG~1, TMA24DB_ONLY_ None NON_AISG~2, RET_ONLY_COAXI AL~3, TMA12DB_AISG~5, TMA24DB_AISG~6

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control Remote Electrical Tilt Control

Interval Type

0~3500 ON(ON), OFF(OFF), NULL(NULL)

N/A

mA

Enumeration Type

ON~0, OFF~1, None NULL~4294967295

Remote Electrical Tilt Control

Enumeration Type

SINGLE_RET(SIN GLE_RET), SINGLE_RET~1, MULTI_RET(MULTI MULTI_RET~17 _RET)

None

Remote Electrical Tilt Control

Enumeration Type

SINGLE(SINGLE), DUAL(DUAL)

SINGLE~1, DUAL~2

None

Remote Electrical Tilt Control

Enumeration Type

REGULAR(REGUL AR), REGULAR~1, DAISY_CHAIN(DAI DAISY_CHAIN~2 SY_CHAIN)

None

Remote Electrical Tilt Control

Interval Type

1~8

N/A

None

None

Enumeration Type

RET(RET), RET~0, VRET~1 VRET(Virtual RET)

None

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Character String Type

0~2 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~36 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~49 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~62

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~254

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Enumeration Type

AISG1.1(AISG1.1), AISG2.0(AISG2.0), 3GPP(3GPP), UNKNOWN(NULL) 0~8

AISG1.1~1, AISG2.0~2, 3GPP~3, UNKNOWN~255 N/A

None

Interval Type

None

None

Character String Type

0~2 characters

N/A

None

None

Character String Type

0~36 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~19 characters

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Character String Type Character String Type

0~127 characters

N/A

None

0~19 characters

N/A

None

Remote Electrical Tilt Control

Enumeration Type

SINGLE_RET(SIN GLE_RET), SINGLE_RET~1, STMA(STMA), STMA~2, MULTI_RET(MULTI MULTI_RET~17 _RET) R0A(R0A), R0B(R0B), RET_PORT(RET_P ORT), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H), NULL(NULL)

None

None

Enumeration Type

R0A~0, R0B~1, RET_PORT~2, R0C~3, R0D~4, R0E~5, R0F~6, R0G~7, R0H~8, NULL~65535

None

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Interval Type

1~8

N/A

None

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Character String Type

0~15 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~32 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Character String Type

0~6 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

-100~300

N/A

0.1degree

Remote Electrical Tilt Control

Character String Type

0~5 characters

N/A

None

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Character String Type

0~32 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~17 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

-1800~1800

N/A

0.1degree

Remote Electrical Tilt Control

Interval Type

-1800~1800

N/A

0.1degree

None

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL) UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL) UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL) UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295 UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295 UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295 UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295

None

Enumeration Type

None

Enumeration Type

None

Enumeration Type

None

Interval Type

0~359

N/A

degree

None

Interval Type

0~359

N/A

degree

None

Interval Type

0~359

N/A

degree

None

Interval Type

0~359

N/A

degree

None None None None Remote Electrical Tilt Control

Interval Type Interval Type Interval Type Interval Type

0~255 0~255 0~255 0~255

N/A N/A N/A N/A

0.1dBi 0.1dBi 0.1dBi 0.1dBi

Interval Type

0 N/A

None

Remote Electrical Tilt Control

Interval Type

60~254

N/A

None

Remote Electrical Tilt Control

Interval Type

0 N/A

None

Remote Electrical Tilt Control

Enumeration Type

RET_PORT(RET_P RET_PORT~2 ORT)

None

Remote Electrical Tilt Control

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

Remote Electrical Tilt Control

Enumeration Type

UER_SELF_DEFIN E(UER_SELF_DEF INE), RET_ONLY_MULTI CORE(RET_ONLY _MULTICORE)

UER_SELF_DEFIN E~0, None RET_ONLY_MULTI CORE~4

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control

Interval Type

0~3500

N/A

mA

Remote Electrical Tilt Control Remote Electrical Tilt Control

Interval Type

0~3500 ON(ON), OFF(OFF), NULL(NULL)

N/A

mA

Enumeration Type

ON~0, OFF~1, None NULL~4294967295

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Interval Type

1~8

N/A

None

Remote Electrical Tilt Control

Enumeration Type

AVAILABLE(AVAIL ABLE), AVAILABLE~0, UNAVAILABLE(UN UNAVAILABLE~1, AVAILABLE), BREAKLINK~2 BREAKLINK(BREA KLINK) -100~300 N/A

None

Remote Electrical Tilt Control None

Interval Type

0.1degree

Interval Type

0~17

N/A

None

Remote Electrical Tilt Control

Interval Type

0~62,255

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~255

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8,255

N/A

None

Remote Electrical Tilt Control

Enumeration Type

R0A(R0A), R0B(R0B), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H)

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7

None

Remote Electrical Tilt Control

Interval Type

0~62,255

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~255

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8,255

N/A

None

Remote Electrical Tilt Control

Enumeration Type

R0A(R0A), R0B(R0B), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H)

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7

None

Remote Electrical Tilt Control

Interval Type

-100~300

N/A

0.1degree

Remote Electrical Tilt Control

Interval Type

0~10

N/A

0.1degree

None

Character String Type

0~49 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

1~2

N/A

None

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Character String Type

0~2 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~36 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~49 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~62

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~254

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Enumeration Type

AISG1.1(AISG1.1), AISG2.0(AISG2.0), 3GPP(3GPP), UNKNOWN(NULL) 0~8

AISG1.1~1, AISG2.0~2, 3GPP~3, UNKNOWN~255 N/A

None

Interval Type

None

None

Character String Type

0~2 characters

N/A

None

None

Character String Type

0~36 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~19 characters

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control

Character String Type Character String Type

0~127 characters

N/A

None

0~19 characters

N/A

None

Remote Electrical Tilt Control

Enumeration Type

SINGLE_RET(SIN GLE_RET), SINGLE_RET~1, STMA(STMA), STMA~2, MULTI_RET(MULTI MULTI_RET~17 _RET) R0A(R0A), R0B(R0B), RET_PORT(RET_P ORT), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H), NULL(NULL)

None

None

Enumeration Type

R0A~0, R0B~1, RET_PORT~2, R0C~3, R0D~4, R0E~5, R0F~6, R0G~7, R0H~8, NULL~65535

None

Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Remote Electrical Tilt Control

Interval Type

1~2

N/A

None

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Character String Type

0~32 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~359

N/A

degree

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.1dBi

Remote Electrical Tilt Control

Character String Type

0~6 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

-100~300

N/A

0.1degree

Remote Electrical Tilt Control

Character String Type

0~5 characters

N/A

None

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, None BandVI~6, BandVII~7, BandVIII~8, BandIX~9, BandX~10

Remote Electrical Tilt Control

Character String Type

0~32 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~17 characters

N/A

None

Remote Electrical Tilt Control

Character String Type

0~15 characters

N/A

None

Remote Electrical Tilt Control

Interval Type

0~4294967295

N/A

0.25dB

Remote Electrical Tilt Control

Interval Type

0~4294967295 UNSUPPORT(UNS UPPORT), SUPPORT_BYPAS S(SUPPORT_BYP ASS), SUPPORT_VSWR( SUPPORT_VSWR) , VSWR/BYPASS(V SWR/BYPASS), NULL(NULL) 0~255 UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL) UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL) UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL)

N/A

0.25dB

None

Enumeration Type

UNSUPPORT~0, SUPPORT_BYPAS S~1, SUPPORT_VSWR None ~2, VSWR/BYPASS~3, NULL~4294967295

None

Interval Type

N/A

0.25dB

None

Enumeration Type

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295 UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295 UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295

None

Enumeration Type

None

Enumeration Type

None

Enumeration Type

UNUSED(UNUSED ), BandI(BandI), BandII(BandII), BandIII(BandIII), BandIV(BandIV), BandV(BandV), BandVI(BandVI), BandVII(BandVII), BandVIII(BandVIII), BandIX(BandIX), BandX(BandX), NULL(NULL)

UNUSED~0, BandI~1, BandII~2, BandIII~3, BandIV~4, BandV~5, BandVI~6, None BandVII~7, BandVIII~8, BandIX~9, BandX~10, NULL~4294967295

None

Interval Type

0~359

N/A

degree

None

Interval Type

0~359

N/A

degree

None

Interval Type

0~359

N/A

degree

None

Interval Type

0~359

N/A

degree

None None

Interval Type Interval Type

0~255 0~255

N/A N/A

0.1dBi 0.1dBi

None None

Interval Type Interval Type

0~255 0~255

N/A N/A

0.1dBi 0.1dBi

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

Remote Electrical Tilt Control Remote Electrical Tilt Control Remote Electrical Tilt Control Remote Electrical Tilt Control Remote Electrical Tilt Control

Interval Type

0~35

N/A

None

Interval Type

1~2

N/A

None

Interval Type

0~17

N/A

None

Interval Type

0~4294967295

N/A

0.25dB

Enumeration Type

NORMAL(NORMAL NORMAL~0, ), BYPASS~1, None BYPASS(BYPASS), NULL~4294967295 NULL(NULL)

Remote Electrical Tilt Control

Enumeration Type

AVAILABLE(AVAIL ABLE), AVAILABLE~0, UNAVAILABLE(UN UNAVAILABLE~1, AVAILABLE), BREAKLINK~2 BREAKLINK(BREA KLINK) R0A(R0A), R0B(R0B), R0C(R0C), R0D(R0D), R0E(R0E), R0F(R0F), R0G(R0G), R0H(R0H)

None

Remote Electrical Tilt Control

Enumeration Type

R0A~0, R0B~1, R0C~2, R0D~3, R0E~4, R0F~5, R0G~6, R0H~7

None

Remote Electrical Tilt Control

Interval Type

0~62,255

N/A

None

Remote Electrical Tilt Control

Interval Type

0~8,255

N/A

None

Remote Electrical Tilt Control

Interval Type

4~5,60~255

N/A

None

Remote Electrical Tilt Control

Interval Type

0~255

N/A

0.25dB

Remote Electrical Tilt Control

Enumeration Type

NORMAL(NORMAL NORMAL~0, ), BYPASS~1 BYPASS(BYPASS)

None

None

Interval Type

0~62

N/A

None

None

Interval Type

60~254

N/A

None

None

Interval Type

0 N/A

None

None

Enumeration Type

R0A(R0A), R0B(R0B), R1A(R1A), R1B(R1B), R2A(R2A), R2B(R2B), R3A(R3A), R3B(R3B), R4A(R4A), R4B(R4B), R5A(R5A), R5B(R5B), R6A(R6A), R6B(R6B), R7A(R7A), R7B(R7B), NULL(NULL) 60~254

R0A~0, R0B~1, R1A~16, R1B~17, R2A~32, R2B~33, R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113, NULL~255

None

None

Interval Type

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

60~254

N/A

None

None

Interval Type

0 N/A

None

None

Character String Type

0~64 characters

N/A

None

None

Interval Type

8 N/A

None

None

Interval Type

0~62

N/A

None

None

Enumeration Type

R0A(R0A), R0B(R0B), R1A(R1A), R1B(R1B), R2A(R2A), R2B(R2B), R3A(R3A), R3B(R3B), R4A(R4A), R4B(R4B), R5A(R5A), R5B(R5B), R6A(R6A), R6B(R6B), R7A(R7A), R7B(R7B), NULL(NULL)

R0A~0, R0B~1, R1A~16, R1B~17, R2A~32, R2B~33, R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113, NULL~255

None

None

Enumeration Type

R0A(R0A), R0B(R0B), R1A(R1A), R1B(R1B), R2A(R2A), R2B(R2B), R3A(R3A), R3B(R3B), R4A(R4A), R4B(R4B), R5A(R5A), R5B(R5B), R6A(R6A), R6B(R6B), R7A(R7A), R7B(R7B), NULL(NULL)

R0A~0, R0B~1, R1A~16, R1B~17, R2A~32, R2B~33, R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113, NULL~255

None

None

Character String Type

0~64 characters

N/A

None

None

Interval Type

60~254

N/A

None

None

Enumeration Type

NEGATIVE_45, POSITIVE_45, HORIZONTAL, VERTICAL, LEFT, RIGHT, POSITIVE_NEGATI VE_45

NEGATIVE_45~0, POSITIVE_45~1, HORIZONTAL~2, VERTICAL~3, None LEFT~4, RIGHT~5, POSITIVE_NEGATI VE_45~6

None

Interval Type

0 N/A

None

None

Interval Type

60~254

N/A

None

None

Interval Type

1~8

N/A

None

None

Enumeration Type

R0A(R0A), R0B(R0B), R1A(R1A), R1B(R1B), R2A(R2A), R2B(R2B), R3A(R3A), R3B(R3B), R4A(R4A), R4B(R4B), R5A(R5A), R5B(R5B), R6A(R6A), R6B(R6B), R7A(R7A), R7B(R7B), NULL(NULL) NEGATIVE_45, POSITIVE_45, HORIZONTAL, VERTICAL, LEFT, RIGHT, POSITIVE_NEGATI VE_45

R0A~0, R0B~1, R1A~16, R1B~17, R2A~32, R2B~33, R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113, NULL~255

None

None

Enumeration Type

NEGATIVE_45~0, POSITIVE_45~1, HORIZONTAL~2, VERTICAL~3, None LEFT~4, RIGHT~5, POSITIVE_NEGATI VE_45~6

None

Interval Type

-150~150,32767

N/A

0.1degree

None

Interval Type

-150~150,32767

N/A

0.1degree

None

Enumeration Type

R0A(R0A), R0B(R0B), R1A(R1A), R1B(R1B), R2A(R2A), R2B(R2B), R3A(R3A), R3B(R3B), R4A(R4A), R4B(R4B), R5A(R5A), R5B(R5B), R6A(R6A), R6B(R6B), R7A(R7A), R7B(R7B), NULL(NULL) NEGATIVE_45, POSITIVE_45, HORIZONTAL, VERTICAL, LEFT, RIGHT, POSITIVE_NEGATI VE_45 NEGATIVE_45, POSITIVE_45, HORIZONTAL, VERTICAL, LEFT, RIGHT, POSITIVE_NEGATI VE_45

R0A~0, R0B~1, R1A~16, R1B~17, R2A~32, R2B~33, R3A~48, R3B~49, R4A~64, R4B~65, R5A~80, R5B~81, R6A~96, R6B~97, R7A~112, R7B~113, NULL~255

None

None

Enumeration Type

NEGATIVE_45~0, POSITIVE_45~1, HORIZONTAL~2, VERTICAL~3, None LEFT~4, RIGHT~5, POSITIVE_NEGATI VE_45~6 NEGATIVE_45~0, POSITIVE_45~1, HORIZONTAL~2, VERTICAL~3, None LEFT~4, RIGHT~5, POSITIVE_NEGATI VE_45~6

None

Enumeration Type

None

Interval Type

0,1,2,4

N/A

None

None

Interval Type

0~255

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~4

N/A

None

None

Interval Type

0~4,8

N/A

None

None

Compound Type

2000-01-01 00:00:00~2038-12- N/A 31 23:59:59

None

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~65535

N/A

per mill

None

Interval Type

0~65535

N/A

per mill

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~65535

N/A

per mill

None

Interval Type

0~65535

N/A

per mill

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~65535

N/A

per mill

None

Interval Type

0~65535

N/A

per mill

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

None

Character String Type

0~31 characters

N/A

packet

None

Interval Type

0 N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

None

Enumeration Type

UNAVAILABLE(Un available), UNAVAILABLE~0, AVAILABLE(Availa AVAILABLE~1 ble)

None

None

Interval Type

1~4

N/A

None

None

Interval Type

0 N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~5

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

None

Enumeration Type

UNAVAILABLE(Un available), UNAVAILABLE~0, AVAILABLE(Availa AVAILABLE~1 ble)

None

None

Interval Type

1~4

N/A

None

None

Interval Type

0 N/A

None

None

Enumeration Type

UMTS(UMTS), GSM(GSM), UMTS~0, GSM~1, DEFAULT(DEFAUL DEFAULT~255 T)

None

None

Enumeration Type

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

None

Enumeration Type

UNAVAILABLE(Un available), UNAVAILABLE~0, AVAILABLE(Availa AVAILABLE~1 ble)

None

None

Interval Type

0~1

N/A

None

None

Enumeration Type

IN(Input), OUT(Output)

IN~0, OUT~1

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

TWISTEDTWISTED-PAIR~0, PAIR(Twisted-Pair), None COAXIAL~1 COAXIAL(Coaxial)

None

Interval Type

0~1000

N/A

None

Enumeration Type

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

None

Enumeration Type

UNAVAILABLE(Un available), UNAVAILABLE~0, AVAILABLE(Availa AVAILABLE~1 ble)

None

None

Interval Type

0~100000

N/A

ns

None

Interval Type

1~4

N/A

None

None

Interval Type

0~17

N/A

None

None

Interval Type

0~7

N/A

None

RGPS CLOCK TRANSMIT FROM RRU TO BBU THROUGH CPRI

Interval Type

0~1,60~254

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

USER_CONFIG(Us er Config), SEARCH_WITH_D URATION(Search with duration), SEARCH_WITH_P RECISION(Search with precision), AUTO_SEARCH(A uto Search)

USER_CONFIG~0, SEARCH_WITH_D URATION~1, None SEARCH_WITH_P RECISION~2, AUTO_SEARCH~3

None

Interval Type

180000000~180000 N/A 000

1e-6 degree

None

Interval Type

90000000~9000000 N/A 0

1e-6 degree

None

Interval Type

-1000~10000

N/A

None

Interval Type

0~89

N/A

degree

None

Interval Type

0~100000

N/A

ns

None

Interval Type

1~2880

N/A

min

None

Interval Type

1~100

N/A

None

Enumeration Type

TWISTEDTWISTED-PAIR~0, PAIR(Twisted-Pair), None COAXIAL~1 COAXIAL(Coaxial)

None

Interval Type

0~1000

N/A

None

Character String Type

1~63 characters

N/A

None

None

Enumeration Type

Lock(Yes), Unlock(No)

Lock~0, Unlock~1

None

None

Enumeration Type

Valid(Valid), Invalid(Invalid)

Valid~0, Invalid~1

None

None

Enumeration Type

Valid(Valid), Invalid(Invalid)

Valid~0, Invalid~1

None

None

Enumeration Type

NotFixed(Not NotFixed~0, Fixed), Fixed(Fixed) Fixed~1

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Valid(Valid), Invalid(Invalid)

Valid~0, Invalid~1

None

None

Interval Type

0~100

N/A

None

None

Enumeration Type

NOTEXIST(Inexiste nt), ANTENNASHORTE D(Antenna Shorted), ANTENNAOPENE D(Antenna Opened), SELF_CHECK_FAI LURE(Self-check Failure), COMEXCEPTION( COM Port Communication Fault), NORMAL(Normal), UNKNOWN(Unkno wn Exception), USCUINVALID(US CU Invalid), UNKNOWN_STAR _CARD(Unknown Star Card)

NOTEXIST~0, ANTENNASHORTE D~1, ANTENNAOPENE D~2, SELF_CHECK_FAI LURE~3, None COMEXCEPTION~ 4, NORMAL~5, UNKNOWN~6, USCUINVALID~7, UNKNOWN_STAR _CARD~8

None

Enumeration Type

M12M(M12M), UT(UT), RT(RT), JPS15L(JPS15L), K161(K161), GG16(GG16), JNS100(JNS100), RGPS(RGPS), CWAIN(CWAIN), RTSMT(RTSMT), UBLOX5(UBLOX5), BD7702(BD7702), NAVIOR(NAVIOR), PPSTOD(PPSTOD) , M1000(M1000), TRGPS(TRGPS), BD7702CMS(BD77 02CMS), OEM4(OEM4), UNKNOWN(Unkno wn)

M12M~0, UT~1, RT~2, JPS15L~3, K161~4, GG16~5, JNS100~6, RGPS~7, CWAIN~8, RTSMT~9, UBLOX5~10, None BD7702~11, NAVIOR~12, PPSTOD~13, M1000~14, TRGPS~15, BD7702CMS~16, OEM4~17, UNKNOWN~65535

None

Interval Type

0~100

N/A

None

None

Enumeration Type

GPS(GPS), GLONASS(GLONA SS), GPS/GLONASS(G PS/GLONASS with GPS Prioritized), COMPASS(COMP ASS), COMPASS/GPS(C OMPASS/GPS with COMPASS Prioritized), GPS/COMPASS(G PS/COMPASS with GPS Prioritized)

GPS~0, GLONASS~1, GPS/GLONASS~2, None COMPASS~3, COMPASS/GPS~4, GPS/COMPASS~5

None

Interval Type

0~100

N/A

None

None

Enumeration Type

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

None

Interval Type

1~4

N/A

None

None

Interval Type

0~1

N/A

None

IEEE1588 V2 Clock Synchronization Enumeration Type Clock over IP (Huawei proprietary)

HW_DEFINED(Hua Wei Defined HW_DEFINED~0, Protocol), PTP(PTP PTP~1 Protocol)

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

IEEE1588 V2 Clock Synchronization IP Address Type Clock over IP (Huawei proprietary)

Valid IP address

N/A

None

IEEE1588 V2 Clock Synchronization IP Address Type Clock over IP (Huawei proprietary)

Valid IP address

N/A

None

IEEE1588 V2 Clock Interval Type Synchronization

0~127

N/A

None

None

Enumeration Type

E2E(E2E), P2P(P2P)

E2E~0, P2P~1

None

None

Enumeration Type

OFF(OFF), ON(ON) OFF~0, ON~1

None

None

Interval Type

0~255

N/A

None

None

Interval Type

0~255

N/A

None

None

Interval Type

0~255

N/A

None

None

Interval Type

0~255

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Enumeration Type

NO(NO), YES(YES) NO~0, YES~1

None

None

Compound Type

14 characters

N/A

None

None

Enumeration Type

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

None

Enumeration Type

UNAVAILABLE(Un available), UNAVAILABLE~0, AVAILABLE(Availa AVAILABLE~1 ble)

None

IEEE1588 V2 Clock Enumeration Type Synchronization

UNICAST(Unicast), UNICAST~0, L2_MULTICAST(L2 None L2_MULTICAST~2 Multicast)

IEEE1588 V2 Clock Interval Type Synchronization

-100000~100000

N/A

ns

None

Enumeration Type

ONE_STEP(One Step), TWO_STEP(Two Step) 0~4094

ONE_STEP~0, TWO_STEP~1

None

None

Interval Type

N/A

None

None

Interval Type

2147483648~21474 N/A 83647

None

None

Interval Type

1~4

N/A

None

None

Enumeration Type

1/16(1/16), 1/8(1/8), 1/16~0, 1/8~1, 1/4(1/4), 1/2(1/2), 1/4~2, 1/2~3, 1.0~4, Hz 1.0(1.0), 2.0(2.0), 2.0~5, 4.0~6, 8.0~7 4.0(4.0), 8.0(8.0)

None

Enumeration Type

1/2(1/2), 1.0(1.0), 2.0(2.0), 4.0(4.0), 8.0(8.0), 16.0(16.0), 32.0(32.0), 64.0(64.0), 128.0(128.0)

1/2~0, 1.0~1, 2.0~2, 4.0~3, 8.0~4, Hz 16.0~5, 32.0~6, 64.0~7, 128.0~8

None

Interval Type

0~255

N/A

None

None

Enumeration Type

1588V2(1588V2), 1588V2~0, G.8265.1(G.8265.1) G.8265.1~1

None

None

Interval Type

60~1000

N/A

None

Enumeration Type

IPV4(IPv4), IPV6(IPv6)

IPV4~0, IPV6~1

None

None

IP Address Type

Valid IP address

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

0 N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~5

N/A

None

None

Enumeration Type

DISABLE(DISABLE DISABLE~0, ), ENABLE~1 ENABLE(ENABLE)

None

Synchronization with Ethernet(ITU-T Enumeration Type G.8261)

DEACTIVATED(De activated), DEACTIVATED~0, None ACTIVATED(Activat ACTIVATED~1 ed)

Synchronization with Ethernet(ITU-T Enumeration Type G.8261)

UNAVAILABLE(Un available), UNAVAILABLE~0, AVAILABLE(Availa AVAILABLE~1 ble)

None

None

Interval Type

1~4

N/A

None

None

Enumeration Type

AVAILABLE(Availa ble), UNAVAILABLE(Un available), UNSUPPORT(Unsu pport), PARTAVAILABLE( Partial Available)

AVAILABLE~0, UNAVAILABLE~1, UNSUPPORT~2, None PARTAVAILABLE~ 3

None

Enumeration Type

FORBID(Forbid), ALLOW(Allow), NA(N/A)

FORBID~0, ALLOW~1, NA~2

None

None

Interval Type

1~4

N/A

None

None

Enumeration Type

0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11), 12(12), 13(13), 14(14), 15(15), 16(16), 17(17), AUTO(AUTO)

0~0, 1~1, 2~2, 3~3, 4~4, 5~5, 6~6, 7~7, 8~8, 9~9, 10~10, 11~11, 12~12, None 13~13, 14~14, 15~15, 16~16, 17~17, AUTO~65535

None

Enumeration Type

GPS(GPS Clock), BITS(BITS Clock), IPCLK(IP Clock), SYNCETH(SyncEth Clock), LINECLK(Line Clock), TOD(TOD Clock), PEERCLK(Peer Clock), SYNCETH+IPCLK( SyncEth Clock+IP Clock), GPS+SYNCETH(G PS Clock+SyncEth Clock)

GPS~0, BITS~1, IPCLK~2, SYNCETH~3, LINECLK~4, TOD~5, None PEERCLK~6, SYNCETH+IPCLK~ 7, GPS+SYNCETH~8

Clock Source Switching Manually Enumeration Type or Automatically

AUTO(Auto), AUTO~0, MANUAL(Manual), MANUAL~1, FREE(Free) FREE~2

None

None

Enumeration Type

FREQ(FREQ), TIME(TIME)

FREQ~0, TIME~1

None

None

Enumeration Type

NORMAL(Normal), LOST(Lost), UNAVAILABLE(Un available), FREDVAT(Frequen cy Deviation), JITTER(Jitter), PHASEOUTSCOP E(Phaseoutscope), UNKNOWN(Unkno wn), DIFFSRC(Inconsist ent Clock References) FREERUNNING(Fr ee running), FASTTRACKING(F ast tracking), LOCKED(Locked), HOLDOVER(Holdo ver), UNKNOWN(Unkno wn) GPS(GPS Clock), BITS(BITS Clock), IPCLK(IP Clock), SYNCETH(SyncEth Clock), LINECLK(Line Clock), TOD(TOD Clock), PEERCLK(Peer Clock), SYNCETH+IPCLK( SyncEth Clock+IP Clock), GPS+SYNCETH(G PS Clock+SyncEth Clock)

NORMAL~0, LOST~1, UNAVAILABLE~2, FREDVAT~3, JITTER~4, None PHASEOUTSCOP E~5, UNKNOWN~6, DIFFSRC~7

None

Enumeration Type

FREERUNNING~0, FASTTRACKING~1 , LOCKED~2, None HOLDOVER~3, UNKNOWN~4

None

Enumeration Type

GPS~0, BITS~1, IPCLK~2, SYNCETH~3, LINECLK~4, TOD~5, None PEERCLK~6, SYNCETH+IPCLK~ 7, GPS+SYNCETH~8

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

QL-PRC(QL-PRC), QL-SSU-A(QL-SSUQL-PRC~2, QLA), QL-SSU-B(QLSSU-A~4, QL-SSUSSU-B), QLB~8, QL-EEC2~10, None EEC2(QL-EEC2), QL-EEC1~11, QLQL-EEC1(QLDNU~15 EEC1), QL-DNU(QLDNU)

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~5

N/A

None

None

Enumeration Type

LBBP(LBBP)

LBBP~12290

None

None

Enumeration Type

FDD(Frequency Division Duplex), TDD(Time Division Duplex), TDD_ENHANCE(S upport TDD BF), TDD_8T8R(TDD_8 T8R), TDD_TL(TDD_TL)

FDD~0, TDD~1, TDD_ENHANCE~3, None TDD_8T8R~4, TDD_TL~5

None

Enumeration Type

LOCKED(Locked), LOCKED~0, UNLOCKED(Unlock UNLOCKED~1 ed)

None

None

Interval Type

0~4294967295

N/A

None

Enumeration Type

IMMEDIATE(Immed IMMEDIATE~0, iate), DELAY(Delay) DELAY~2

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

16 N/A

None

None

Interval Type

2147483648~21474 N/A 83647

degree Celsius

None

Interval Type

0~100

N/A

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

15 N/A

None

None

Interval Type

0 N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~1

N/A

None

None

Enumeration Type

NO(NO), YES(YES) NO~0, YES~1

None

None

Interval Type

1~7

N/A

None

None

Bit Field Type

GSM(GSM), UMTS(UMTS), LTE(LTE)

GSM~0, UMTS~1, LTE~2

None

None

Bit Field Type

WS_DISABLE(Wat er-Immersed WS_DISABLE~0, Sensor Disabled), SS_DISABLE~1 SS_DISABLE(Smo g Sensor Disabled)

None

None

Enumeration Type

CONNECTED(Con CONNECTED~0, nected), DISCONNECTED~ None DISCONNECTED( 1 Disconnected) CONNECTED(Con CONNECTED~0, nected), DISCONNECTED~ None DISCONNECTED( 1 Disconnected) 0~4294967295 0~4294967295 N/A N/A None None

None

Enumeration Type

None None

Interval Type Interval Type

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~249 LBR0(NULL), LBR1(1.25), LBR2(2.5), LBR3(3.0), LBR4(4.9), LBR5(6.1), LBR6(9.8)

N/A

None

None

Enumeration Type

LBR0~0, LBR1~1, LBR2~2, LBR3~4, Gbit/s LBR4~8, LBR5~16, LBR6~32

None

Enumeration Type

NEGOTIATED(Neg otiated), NEGOTIATING(Ne gotiating), NOTREADY(Not ready), TIMEOUT(Timeout) , USERCONFIG(US ERCONFIG)

NEGOTIATED~0, NEGOTIATING~1, NOTREADY~2, TIMEOUT~3, USERCONFIG~5

None

None

Enumeration Type

LBR0(NULL), LBR1(1.25), LBR2(2.5), LBR3(3.0), LBR4(4.9), LBR5(6.1), LBR6(9.8)

LBR0~0, LBR1~1, LBR2~2, LBR3~4, Gbit/s LBR4~8, LBR5~16, LBR6~32

None

Enumeration Type

NEGOTIATED(Neg otiated), NEGOTIATING(Ne gotiating), NOTREADY(Not ready), TIMEOUT(Timeout) , USERCONFIG(US ERCONFIG)

NEGOTIATED~0, NEGOTIATING~1, NOTREADY~2, TIMEOUT~3, USERCONFIG~5

None

None None None

Interval Type Interval Type Interval Type

0~62 0~254 0~7

N/A N/A N/A

None None None

None

Enumeration Type

HEAD(Head), TAIL(Tail)

HEAD~4294967294 None , TAIL~4294967295

None

Enumeration Type

LBR0(NULL), LBR1(1.25), LBR2(2.5), LBR3(3.0), LBR4(4.9), LBR5(6.1), LBR6(9.8)

LBR0~0, LBR1~1, LBR2~2, LBR3~4, Gbit/s LBR4~8, LBR5~16, LBR6~32

None

Interval Type

0~62

N/A

None

None

Interval Type

0~1,4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~5

N/A

None

None

Enumeration Type

614M(614M), 1.25G(1.25G), 2.5G(2.5G), 4.9G(4.9G), 6.1G(6.1G), 9.8G(9.8G), UNKNOWN(UNKN OWN), NULL(NULL)

614M~0, 1.25G~1, 2.5G~2, 4.9G~3, 6.1G~4, 9.8G~5, UNKNOWN~254, NULL~255

bit/s

None

Enumeration Type

LOCKED(Locked), UNLOCKED(Unlock ed), SHUTINGDOWN(S hutingdown), INVALID(NULL)

LOCKED~0, UNLOCKED~1, None SHUTINGDOWN~2 , INVALID~4

None

Enumeration Type

INPOSITION(In Position), INPOSITION~0, NOTINPOSITION(N NOTINPOSITION~ None ot In Position), 1, INVALID~255 INVALID(NULL) Slave(Slave), Master(Master), NULL(NULL)

None

Enumeration Type

Slave~0, Master~1, None NULL~255

None

Enumeration Type

SFP_OPTICAL(SF P_OPTICAL), ESFP_OPTICAL(E SFP_OPTICAL), SFP_ELECTRIC(S FP_ELECTRIC), SCSI_ELECTRIC(S CSI_ELECTRIC), GE(GE), UNKNOWN(UNKN OWN), NULL(NULL) 0~4294967295

SFP_OPTICAL~0, ESFP_OPTICAL~1, SFP_ELECTRIC~2, SCSI_ELECTRIC~3 None , GE~4, UNKNOWN~254, NULL~255

None

Interval Type

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295 CPRI_MUX(CPRI MUX), NORMAL(Normal), UNKNOWN(Unkno wn), NULL(NULL) DC(DC), AC(AC)

N/A

None

None

Enumeration Type

CPRI_MUX~0, NORMAL~253, UNKNOWN~254, NULL~255

None

None

Enumeration Type

DC~0, AC~1

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

6~7 UMPT(UMPT), LMPT(LMPT)

N/A UMPT~1, LMPT~12289

None

None

Enumeration Type

None

None

Enumeration Type

Unknown(Unknown) Unknown~0, , NULL(NULL), NULL~1, Active~2, None Active(Active), Standby~3 Standby(Standby)

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

18~19

N/A

None

None None

Enumeration Type Enumeration Type

NULL(NULL) NULL(NULL)

NULL~4294967295 W NULL~4294967295 W

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

0~62

N/A

None

None

Interval Type

0~1,4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

INPOSITION(In Position), INPOSITION~0, NOTINPOSITION(N NOTINPOSITION~ None ot In Position), 1, INVALID~255 INVALID(NULL)

None

Enumeration Type

SFP(SFP), ESFP(ESFP), SFP_ELECTRIC(S FP_ELECTRIC), QSFP(QSFP), EQSFP(QSFP_ELE CTRIC), UNKNOWN(UNKN OWN)

SFP~0, ESFP~1, SFP_ELECTRIC~2, QSFP~3, None EQSFP~4, UNKNOWN~42949 67295

None

Character String Type

0~15 characters

N/A

None

None

Enumeration Type

SINGLEMODE(SIN GLEMODE), MULTIMODE(MUL TIMODE), UNKNOWN(UNKN OWN) 0~65535

SINGLEMODE~0, MULTIMODE~1, None UNKNOWN~42949 67295

None

Interval Type

N/A

nm

None

Interval Type

0~255

N/A

100Mbit/s

None

Interval Type

0~255

N/A

km

None

Interval Type

0~255

N/A

100m

None

Interval Type

0~255

N/A

10m

None

Interval Type

0~255

N/A

10m

None

Interval Type

-1280~1280

N/A

0.1 degree Celsius

None

Interval Type

0~65535

N/A

100microvolt

None

Interval Type

0~65535

N/A

2microampere

None

Interval Type

0~65535

N/A

0.1microwatt

None

Interval Type

0~65535

N/A

0.1microwatt

None

Interval Type

0~255

N/A

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~6

N/A

None

None

Enumeration Type

UIEB(UIEB), UTRPc(UTRPc)

UIEB~9, UTRPc~10 None

None

Enumeration Type

Unknown(Unknown) Unknown~0, , NULL(NULL), NULL~1, Active~2, None Active(Active), Standby~3 Standby(Standby) Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical) Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

Enumeration Type

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~7

N/A

None

None None

Interval Type Interval Type

0~1 0~7

N/A N/A

None None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

18~19

N/A

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~5

N/A

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Character String Type

0~64 characters

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Enumeration Type

NORMAL(NORMAL ), INSTALL(INSTALL) , EXPAND(EXPAND) , UPGRADE(UPGRA DE), TESTING(TESTIN G), ExpandStatus1(Exp andStatus1), ExpandStatus2(Exp andStatus2), ExpandStatus3(Exp andStatus3), ExpandStatus4(Exp andStatus4), ExpandStatus5(Exp andStatus5), ExpandStatus6(Exp andStatus6), ExpandStatus7(Exp andStatus7), ExpandStatus8(Exp andStatus8), ExpandStatus9(Exp andStatus9), ExpandStatus10(Ex pandStatus10)

NORMAL~0, INSTALL~1, EXPAND~2, UPGRADE~3, TESTING~4, ExpandStatus1~5, ExpandStatus2~6, ExpandStatus3~7, None ExpandStatus4~8, ExpandStatus5~9, ExpandStatus6~10, ExpandStatus7~11, ExpandStatus8~12, ExpandStatus9~13, ExpandStatus10~14

None

Compound Type

2000-0101T00:00:00+00:00 N/A ~2037-1231T23:59:59+00:00

None

None

Compound Type

2000-0101T00:00:00+00:00 N/A ~2037-1231T23:59:59+00:00

None

None

Character String Type

0~255 characters NORMAL(NORMAL ), INSTALL(INSTALL) , EXPAND(EXPAND) , UPGRADE(UPGRA DE), TESTING(TESTIN G), ExpandStatus1(Exp andStatus1), ExpandStatus2(Exp andStatus2), ExpandStatus3(Exp andStatus3), ExpandStatus4(Exp andStatus4), ExpandStatus5(Exp andStatus5), ExpandStatus6(Exp andStatus6), ExpandStatus7(Exp andStatus7), ExpandStatus8(Exp andStatus8), ExpandStatus9(Exp andStatus9), ExpandStatus10(Ex pandStatus10)

N/A

None

None

Enumeration Type

NORMAL~0, INSTALL~1, EXPAND~2, UPGRADE~3, TESTING~4, ExpandStatus1~5, ExpandStatus2~6, ExpandStatus3~7, None ExpandStatus4~8, ExpandStatus5~9, ExpandStatus6~10, ExpandStatus7~11, ExpandStatus8~12, ExpandStatus9~13, ExpandStatus10~14

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

390~480

N/A

0.1V

None

Interval Type

390~600

N/A

0.1V

None

Interval Type

0~62

N/A

None

None

Enumeration Type

APM30(APM30), TMC(TMC), BBC(BBC), PS4890(PS4890), OMB(OMB), RFC(RFC), BTS3900(BTS3900 ), BTS3900L(BTS390 0L), BTS3900AL(BTS39 00AL), VIRTUAL(Virtual Cabinet), TP48600A(TP4860 0A), ILC29(ILC29)

APM30~128, TMC~129, BBC~130, PS4890~133, OMB~134, RFC~135, BTS3900~136, BTS3900L~137, BTS3900AL~138, VIRTUAL~142, TP48600A~154, ILC29~155

None

None

Character String Type

0~79 characters

N/A

None

None

Character String Type

0~31 characters

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

0~254

N/A

None

None

Enumeration Type

BBU3900(BBU3900 Subrack), RFU(RFU Subrack), PMU(PMU Subrack), TCU(TCU Subrack), FMU(FMU Subrack), RRU(RRU Subrack), EMU(EMU Subrack), PICO(PICO Subrack), CCU(CCU Subrack), UNKNOW(Unknow Subrack)

BBU3900~128, RFU~129, PMU~130, TCU~131, FMU~132, RRU~134, EMU~137, PICO~147, CCU~148, UNKNOW~255

None

None

Character String Type

0~79 characters

N/A

None

None

Enumeration Type

AC220V(AC 220V), DC-48V(DC -48V), DC+28V(DC +28V), DC+24V(DC +24V), DC-48V-2(DC 48V), AC110V(AC 110V), RDC48V(RDC -48V), NDC-48V(NDC 48V)

AC220V~0, DC48V~1, DC+28V~2, DC+24V~3, DCNone 48V-2~4, AC110V~5, RDC48V~6, NDC-48V~7

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None

Character String Type Character String Type

0~31 characters

N/A

None

None

0~31 characters

N/A

None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

40~59

N/A

None

None

Interval Type

0 N/A

None

Environment Monitoring

Interval Type

0~62

N/A

None

Environment Monitoring

Interval Type

0~254

N/A

None

Environment Monitoring

Interval Type

0~7

N/A

None

Environment Monitoring

Interval Type

1~30

N/A

None

Environment Monitoring

Interval Type

-20~80

N/A

degree Celsius

Environment Monitoring

Interval Type

-20~80

N/A

degree Celsius

Environment Monitoring

Interval Type

0~100

N/A

Environment Monitoring

Interval Type

0~100

N/A

Environment Monitoring

Bit Field Type

48V_DISABLE(-48 Voltage Disabled), RES0(Reserved Sensor 0), RES1(Reserved Sensor 1), RES2(Reserved Sensor 2), TS_DISABLE(Temp erature Sensor Disabled), HS_DISABLE(Humi dity Sensor Disabled)

48V_DISABLE~0, RES0~1, RES1~2, RES2~3, TS_DISABLE~4, HS_DISABLE~5

None

Environment Monitoring

Bit Field Type

WS_DISABLE(Wat er -Immersed Sensor Disabled), SS_DISABLE(Smo g Sensor Disabled), IS_DISABLE(Infrare d Sensor Disabled), GS_DISABLE(Gatin g Sensor Disabled)

WS_DISABLE~0, SS_DISABLE~1, IS_DISABLE~2, GS_DISABLE~3

None

Environment Monitoring Environment Monitoring Environment Monitoring

Interval Type Interval Type Character String Type

2147483648~21474 N/A 83647 0~100 N/A

degree Celsius %

1~7 characters

N/A

None

Character String Type

1~7 characters

N/A

None

None

Character String Type

1~7 characters

N/A

None

None

Character String Type

1~7 characters

N/A

None

None

Character String Type

1~7 characters

N/A

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters

N/A

None

None

Enumeration Type

UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295 CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

11~12

N/A

None

None

Interval Type

0 N/A

None

Environment Monitoring

Interval Type

0~62

N/A

None

Environment Monitoring

Interval Type

0~254

N/A

None

Environment Monitoring

Interval Type

0~7

N/A

None

Environment Monitoring

Interval Type

1~30

N/A

None

None

Bit Field Type

WS_DISABLE(Wat er-Immersed WS_DISABLE~0, Sensor Disabled), SS_DISABLE~1 SS_DISABLE(Smo g Sensor Disabled)

None

Environment Monitoring

Interval Type

0~100

N/A

Environment Monitoring Environment Monitoring Environment Monitoring

Interval Type

-127~127

N/A

degree Celsius

Interval Type

-127~127

N/A

degree Celsius

Interval Type

0~4294967295

N/A

r/min

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

8,14

N/A

None

None

Interval Type

0~3

N/A

None

Environment Monitoring

Interval Type

0~62

N/A

None

Environment Monitoring

Interval Type

0~254

N/A

None

Environment Monitoring

Interval Type

0~7

N/A

None

Environment Monitoring

Interval Type

1~30

N/A

None

Environment Monitoring

Interval Type

-40~10

N/A

degree Celsius

Environment Monitoring

Interval Type

20~80

N/A

degree Celsius

None

Bit Field Type

WS_DISABLE(Wat er-Immersed WS_DISABLE~0, Sensor Disabled), SS_DISABLE~1 SS_DISABLE(Smo g Sensor Disabled)

None

None Environment Monitoring Environment Monitoring Environment Monitoring

Character String Type Interval Type

0~3 characters -127~127

N/A N/A

None degree Celsius

Interval Type

-127~127

N/A

degree Celsius

Interval Type

-127~127

N/A

degree Celsius

None

Interval Type

0~4294967295

N/A

r/min

None

Interval Type

0~4294967295

N/A

r/min

None

Interval Type

0~4294967295

N/A

None None

Interval Type Interval Type

0~4294967295 0~4294967295

N/A N/A

None None

None

Interval Type

0~4294967295

N/A

None

None

Character String Type Character String Type Character String Type

0~18 characters

N/A

None

None

0~32 characters

N/A

None

None

0~18 characters

N/A

None

None

Enumeration Type

dantherm(dantherm ), bw(b + w), huawei(huawei), airsys(air-sys), senguang(senguan g), viasystems(viasyste ms), rittal(rittal), emerson(emerson), APW(APW), hytems(hytems), hontech(hontech), agisson(agisson), pantair(pantair), Panasonic(Panason ic), Gore(Gore), Flex(Flex), Vapel(Vapel), AVC(AVC), JIAYI(JIAYI), Delta(Delta), EBM(EBM), Protechnic(Protech nic), Sanyo(Sanyo) Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

dantherm~0, bw~1, huawei~2, airsys~3, senguang~4, viasystems~5, rittal~6, emerson~7, APW~8, hytems~9, hontech~10, agisson~11, None pantair~12, Panasonic~13, Gore~14, Flex~15, Vapel~16, AVC~17, JIAYI~18, Delta~19, EBM~20, Protechnic~21, Sanyo~22

None

Enumeration Type

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters

N/A

None

None

Enumeration Type

UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295 CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

8,14

N/A

None

None

Interval Type

0~3

N/A

None

Environment Monitoring

Interval Type

-99~70

N/A

degree Celsius

Environment Monitoring

Interval Type

-99~70

N/A

degree Celsius

Environment Monitoring

Interval Type

-99~70

N/A

degree Celsius

Environment Monitoring

Interval Type

0~30

N/A

degree Celsius

Environment Monitoring

Interval Type

0~30

N/A

degree Celsius

Environment Monitoring

Interval Type

0~30

N/A

degree Celsius

Environment Monitoring

Interval Type

0~30

N/A

degree Celsius

None

Interval Type

0~62

N/A

None

None

Interval Type

7 N/A

None

None

Interval Type

0 N/A

None

Environment Monitoring

Interval Type

0~62

N/A

None

Environment Monitoring

Interval Type

0~254

N/A

None

Environment Monitoring

Interval Type

0~7

N/A

None

Environment Monitoring

Interval Type

1~30

N/A

None

Environment Monitoring

Enumeration Type

APM100(APM 100), APM200(APM 200), APM30(APM 30), EPS4890(EPS4890 ), EPS4815(EPS4815 ), SC48200(SC48200) , EPS48200(EPS482 00), TP48300A(TP4830 0A), ETP(ETP)

APM100~0, APM200~1, APM30~2, EPS4890~3, EPS4815~4, SC48200~5, EPS48200~7, TP48300A~8, ETP~10

None

Environment Monitoring

Interval Type

60~300

N/A

Environment Monitoring

Interval Type

60~300

N/A

Environment Monitoring

Interval Type

350~556

N/A

0.1V

Environment Monitoring

Interval Type

580~600

N/A

0.1V

Environment Monitoring

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Environment Monitoring

Interval Type

350~556

N/A

0.1V

Environment Monitoring

Interval Type

-20~20

N/A

degree Celsius

Environment Monitoring

Interval Type

35~80

N/A

degree Celsius

None

Interval Type

0~50

N/A

None

Interval Type

50~100

N/A

Environment Monitoring

Bit Field Type

BT1_DISABLE(Batt ery Temperature Sensor 1 Disabled), AH_DISABLE(Cabi net Humidity Sensor Disabled), AT1_DISABLE(Cab inet Temperature Sensor 1 Disabled), BT2_DISABLE(Batt ery Temperature Sensor 2 Disabled)

BT1_DISABLE~0, AH_DISABLE~1, AT1_DISABLE~2, BT2_DISABLE~3

None

Environment Monitoring

Bit Field Type

WS_DISABLE(Wat er-Immersed Sensor Disabled), WS_DISABLE~0, SS_DISABLE(Smo SS_DISABLE~1, g Sensor Disabled), GS_DISABLE~2 GS_DISABLE(Gatin g Sensor Disabled)

None

Environment Monitoring

Interval Type

2147483648~21474 N/A 83647

Environment Monitoring Environment Monitoring Environment Monitoring Environment Monitoring

Character String Type Character String Type Interval Type

1~7 characters 1~7 characters

N/A N/A

V A

2147483648~21474 N/A 83647 0~100 N/A

degree Celsius

Interval Type

Environment Monitoring

Enumeration Type

PowerOn(Power on), LowVoltagePowerO ff(Low voltage power off), MasterControlPowe rOff(Master control power off), HighTemperaturePo werOff(High temperature power off), LowTemperaturePo werOff(Low temperature power off)

PowerOn~0, LowVoltagePowerO ff~1, MasterControlPowe rOff~2, None HighTemperaturePo werOff~3, LowTemperaturePo werOff~4

Environment Monitoring

Enumeration Type

BoostCharging(Boo st-Charging), FloatCharging(FloatBoostCharging~0, Charging), FloatCharging~1, ForceBoostChargin ForceBoostChargin None g(ForceBoostg~2, Discharging~3, Charging), Sleeping~4 Discharging(Dischar ging), Sleeping(Sleeping)

Environment Monitoring

Character String Type

1~7 characters

N/A

Environment Monitoring

Enumeration Type

CurrentLimiting(Cur CurrentLimiting~0, rent limiting), NoCurrentLimiting~ None NoCurrentLimiting( 1 No current limiting)

Environment Monitoring

Enumeration Type

PowerOn(Power on), LowVoltagePowerO ff(Low voltage power off), MasterControlPowe rOff(Master control power off), ManualPowerOff(M anual power off), HighTemperaturePo werOff(High temperature power off)

PowerOn~0, LowVoltagePowerO ff~1, MasterControlPowe None rOff~2, ManualPowerOff~3, HighTemperaturePo werOff~4

Environment Monitoring

Interval Type

0~100

N/A

Environment Monitoring

Interval Type

2147483648~21474 N/A 83647 CHARGE(Charging) , CHARGE~0, DISCHARGE(Disch DISCHARGE~1, arging), REC~2, END~3 REC(Recording), END(Finished)

degree Celsius

None

Enumeration Type

None

None

Character String Type

1~7 characters

N/A

None

Character String Type

1~7 characters

N/A

None

Interval Type

2147483648~21474 N/A 83647

degree Celsius

None None

Interval Type Interval Type

0~4294967295 0~4294967295

N/A N/A

None None

None

Interval Type

0~4294967295

N/A

None

None

Character String Type Character String Type Character String Type

0~18 characters

N/A

None

None

0~32 characters

N/A

None

None

0~18 characters Huawei(Huawei Technologies Co.,Ltd.), Emerson(Emerson Network Power Co.,Ltd.), HoldluckZYT(ShenZhen Holdluck-ZYT Power Supply Technology Co.,LTD.), PowerOne(Power-One LimiTed), Kehua(Kehua Communication Power Co.,Ltd), DeltaElectronics(De lta Electronics Power(Dong guan) LTD.), EltekEnergy(Eltek Energy Technology(Dong Guan)Ltd.), Switchtec(Hangzho u Switchtec Power Systems Co.,LTD.), TycoElectronics(Tyc o Electronics (Shang hai) Co.,Ltd.), ARTESYN(Artesyn Technologies Co.,Ltd.), UNSUPPORTED(N ot Supported), SUPPORTED(Supp orted)

N/A

None

None

Enumeration Type

Huawei~0, Emerson~1, Holdluck-ZYT~2, Power-One~3, Kehua~4, DeltaElectronics~5, EltekEnergy~6, Switchtec~7, TycoElectronics~8, ARTESYN~9, None CHROMA~10, LuckyValley~11, ACBEL~12, Zippy~13, GuoyaoElectronics~ 14, DPC~15, GoldPower~16, SungrowPowerSup ply~17, Ecom~18

None

Enumeration Type

UNSUPPORTED~0 None , SUPPORTED~1

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1 SUCCEEDED(Succ eeded), BRDNOTREADY(T he board is unavailable), UNSUPPORTED(T he PSU intelligent shutdown is not supported by the board), BATNOTEXIST(Th e battery does not exist), INTERNALERR(Int ernal error)

None

None

Enumeration Type

SUCCEEDED~0, BRDNOTREADY~1 , None UNSUPPORTED~2 , BATNOTEXIST~3, INTERNALERR~4

None

Interval Type

0~65535

N/A

min

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

None

Enumeration Type

UNSUPPORTED(N ot Supported), UNSUPPORTED~0 None SUPPORTED(Supp , SUPPORTED~1 orted) DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Enumeration Type

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

7 N/A

None

None

Interval Type

0 N/A

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

1~1000

N/A

0.1kVA

None

Character String Type Character String Type Interval Type

1~7 characters

N/A

cm

None

1~7 characters

N/A

None

0~4294967295

N/A

None

Interval Type

0~62

N/A

None

None

Interval Type

7 N/A

None

None

Interval Type

0 N/A

None

None

Enumeration Type

INNER(Inner), OUTER(Outer)

INNER~0, OUTER~1

None

None

Interval Type

30~240

N/A

day

None

Interval Type

433~576

N/A

0.1V

None

Interval Type

5~5000

N/A

Ah

None

Interval Type

5~25

N/A

0.01

None

Interval Type

432~575

N/A

0.1V

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

40~70

N/A

degree Celsius

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

350~556

N/A

0.1V

None

Interval Type

0~500

N/A

mV/degree Celsius

None

Interval Type

-20~20

N/A

degree Celsius

None

Interval Type

35~80

N/A

degree Celsius

None

Interval Type

1~2

N/A

None

None

Enumeration Type

VRLA_BAT(VRLA VRLA_BAT~2, Battery), LI_BAT(LiLI_BAT~3 Ion Battery)

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Compound Type

2000-01-01~209912-31

N/A

None

None

Interval Type

5~5000

N/A

Ah

None

Interval Type

0~62

N/A

None

None

Interval Type

7 N/A

None

None

Interval Type

0 N/A

None

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

1~5000

N/A

0.01h

None

Interval Type

80~100

N/A

None

Interval Type

170~220

N/A

0.01V/cell

None

Interval Type

1~50

N/A

None

None

Interval Type

1~100

N/A

None

Interval Type

1~240

N/A

min

None

Interval Type

400~540

N/A

0.1V

None

Enumeration Type

NOAUTOTEST(No Auto Test), PERIOD(Period Auto Test), POWERCUT(Powe r Off Auto Test), PERIODPOWERC UT(Period and Power Off Auto Test)

NOAUTOTEST~0, PERIOD~1, POWERCUT~2, None PERIODPOWERC UT~3

None

Interval Type

30~240

N/A

day

None

Interval Type

1~60

N/A

day

None

Enumeration Type

STANDARD(Stand ard Test), SIMPLE(Simple Test), TIMER(Period Test), PWROFF(Power Cut Test), NONE(None Test)

STANDARD~0, SIMPLE~1, TIMER~2, PWROFF~3, NONE~4

None

None

Compound Type

2000-01-01 00:00:00~2038-12- N/A 31 23:59:59 BelowEndVol(Lower Than End Voltage), OverTime(Test Timeout), CurrRecover(Power Resume Stop Power Drop Auto Test), ManualEnd(Manual Stop Test), AlmEnd(Alarm Stop Test)

None

None

Enumeration Type

BelowEndVol~0, OverTime~1, CurrRecover~2, ManualEnd~3, AlmEnd~4

None

None

Enumeration Type

None(No result), Normal(Battery normal), None~0, Normal~1, None PreAlm(Battery pre- PreAlm~2, Alm~3 alarm), Alm(Battery alarm)

None

Interval Type

0~100

N/A

None

Character String Type

1~7 characters

N/A

None

Character String Type

1~7 characters

N/A

None

Character String Type

1~7 characters

N/A

None

Interval Type

0~4294967295

N/A

Ah

None

Interval Type

2147483648~21474 N/A 83647 0~62 N/A

degree Celsius

None

Interval Type

None

None

Interval Type

7 N/A

None

None

Interval Type

1~7

N/A

None

None

Enumeration Type

NORMAL(Normal), COMMUNICATEFA ILED(Communicatio n failed), SHUTDOWN(Shut down), FAULT(Fault), PROTECT(Fault), UNCONFIGURED( Unconfigured), ILLEGAL(Unconfigu red) 0~18 characters

NORMAL~0, COMMUNICATEFA ILED~1, SHUTDOWN~2, None FAULT~3, PROTECT~4, UNCONFIGURED~ 5, ILLEGAL~6

None

Character String Type

N/A

None

None

Enumeration Type

Huawei(Huawei Technologies Co.,Ltd.), Emerson(Emerson Network Power Co.,Ltd.), HoldluckZYT(ShenZhen Holdluck-ZYT Power Supply Technology Co.,LTD.), PowerOne(Power-One LimiTed), Kehua(Kehua Communication Power Co.,Ltd), DeltaElectronics(De lta Electronics Power(Dong guan) LTD.), EltekEnergy(Eltek Energy Technology(Dong Guan)Ltd.), Switchtec(Hangzho u Switchtec Power Systems Co.,LTD.), TycoElectronics(Tyc o Electronics (Shang hai) Co.,Ltd.), ARTESYN(Artesyn Technologies Co.,Ltd.), 0~4294967295

Huawei~0, Emerson~1, Holdluck-ZYT~2, Power-One~3, Kehua~4, DeltaElectronics~5, EltekEnergy~6, Switchtec~7, TycoElectronics~8, ARTESYN~9, None CHROMA~10, LuckyValley~11, ACBEL~12, Zippy~13, GuoyaoElectronics~ 14, DPC~15, GoldPower~16, SungrowPowerSup ply~17, Ecom~18

None

Interval Type

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Character String Type

0~18 characters

N/A

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

40~59

N/A

None

None

Interval Type

0 N/A

None

None

Interval Type

0~5

N/A

None

Environment Monitoring

Character String Type

0~50 characters

N/A

None

Environment Monitoring

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Interval Type

0~62

N/A

None

None

Interval Type

0~1,7~8,11~12,14~ N/A 15,40~254

None

None

Interval Type

0~3,18~19

N/A

None

None

Interval Type

0~35

N/A

None

Environment Monitoring

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Environment Monitoring

Interval Type

65033~65233

N/A

None

Environment Monitoring

Enumeration Type

BOOL(Digital Port), VALUE(Analog BOOL~0, VALUE~1 None Port)

Environment Monitoring

Enumeration Type

HIGH(High Voltage), LOW(Low HIGH~0, LOW~1 Voltage)

None

Environment Monitoring

Interval Type

-99999~999999

N/A

0.01

Environment Monitoring

Interval Type

-99999~999999

N/A

0.01

Environment Monitoring

Enumeration Type

VOLTAGE(Voltage Type), VOLTAGE~0, CURRENT(Current CURRENT~1 Type)

None

Environment Monitoring

Interval Type

-99999~999999

N/A

0.01

Environment Monitoring

Interval Type

-99999~999999

N/A

0.01

Environment Monitoring

Interval Type

0~999999

N/A

0.01V or 0.01mA

Environment Monitoring

Interval Type

0~999999

N/A

0.01V or 0.01mA

None

Enumeration Type

ALL(All Type), SSL(Only SSL)

ALL~0, SSL~1

None

None

Enumeration Type

NONE(Verify None), PEER(Verify NONE~0, PEER~1 None Peer Certificate)

None

Interval Type

0~62

N/A

None

None

Interval Type

60~254

N/A

None

None

Interval Type

0 N/A

None

None

Character String Type

0~31 characters

N/A

None

None

Enumeration Type

MAAU(MAAU)

MAAU~35

None

None

Enumeration Type

LOCKED(Locked), LOCKED~0, UNLOCKED(Unlock UNLOCKED~1 ed) Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical) Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP)

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

15~100

N/A

0.1

None

Interval Type

15~30

N/A

0.1

None

Interval Type

0~7

N/A

None

None

Interval Type

0~249

N/A

None

None

Enumeration Type

TRUNK(TRUNK)

TRUNK~0

None

None

Enumeration Type

TD_SCDMA(TD_S CDMA), LTE_TDD(LTE_TD D), TDS_TDL(TDS_TD L), LTE_FDD(LTE_FD D), WiMAX_LTE(WiMA X_LTE), CDMA_LTE(CDMA _LTE), GSM_LTE(GSM_L TE), UMTS_ONLY(UMT S_ONLY), UMTS_LTE(UMTS_ LTE)

TD_SCDMA~2, LTE_TDD~4, TDS_TDL~6, LTE_FDD~8, WiMAX_LTE~20, None CDMA_LTE~40, GSM_LTE~72, UMTS_ONLY~128, UMTS_LTE~136

None

Interval Type

0~8

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~500

N/A

0.1dBm

None

Interval Type

0~65535

N/A

0.1dB

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

0~6

N/A

None

None

Character String Type

0~24 characters LO_TD(LO_TD), TL(TL), LO(LO), WO(WO), WL(WL), C0(C0), CL(CL), CW(CW), CWL(CWL), GO(GO), GL(GL), GW(GW), GWL(GWL), GC(GC), GCL(GCL), GCW(GCW), GCWL(GCWL), UO(UO), UL(UL), UW(UW), UWL(UWL), UC(UC), UCL(UCL), UCW(UCW), UCWL(UCWL), GU(GU), UGL(UGL), UGW(UGW), UGWL(UGWL), UGC(UGC), UGCL(UGCL), UGCW(UGCW), UGCWL(UGCWL), NULL(Invalid) CONNECTHEAD(A ccess from chain head or ring head), CONNECTTAIL(Ac cess from ring tail), CONNECTBOTH(A ccess from both ends of the ring), SEPERATEBYBRE AK(Seperated by break points), LINKDOWN(Link down)

N/A

None

None

Enumeration Type

LO_TD~4, TL~6, LO~8, WO~16, WL~20, C0~32, CL~40, CW~48, CWL~56, GO~64, GL~72, GW~80, GWL~88, GC~96, GCL~104, GCW~112, GCWL~120, UO~128, UL~136, UW~144, None UWL~152, UC~160, UCL~168, UCW~176, UCWL~184, GU~192, UGL~200, UGW~208, UGWL~216, UGC~224, UGCL~232, UGCW~240, UGCWL~248, NULL~255

None

Enumeration Type

CONNECTHEAD~0 , CONNECTTAIL~1, CONNECTBOTH~2 None , SEPERATEBYBRE AK~3, LINKDOWN~4

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~4294967295

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

1~60

N/A

min

None

Enumeration Type

POW_IQ_MODE(P OW_IQ_MODE), POW_IQ_MODE~0 POW_MODE(POW , POW_MODE~1, None _MODE), IQ_MODE~2 IQ_MODE(IQ_MOD E)

None

Interval Type

9~18

N/A

None

Enumeration Type

HALFSECOND(HA LFSECOND), ONESECOND(ONE SECOND), TWOSECOND(TW OSECOND), THREESECOND(T HREESECOND), FOURSECOND(FO URSECOND), FIVESECOND(FIV ESECOND) 0~65535 0~31 characters SUCCESS(SUCCE SS), FAILURE(FAILURE ), UNKNOWTYPE(Un know Type)

HALFSECOND~5, ONESECOND~10, TWOSECOND~20, THREESECOND~3 None 0, FOURSECOND~40 , FIVESECOND~50

None None

Interval Type Character String Type

N/A N/A

None None

None

Enumeration Type

SUCCESS~0, FAILURE~1, None UNKNOWTYPE~25 5

None

Enumeration Type

USERDEFINE(USE RDEFINE), USERDEFINE~0, DEFAULT(DEFAUL DEFAULT~1 T) 0~1000000000 N/A

None

None

Interval Type

0.000000001

None

Enumeration Type

1.25G(1.25G), 2.5G(2.5G), 3.0G(3.0G), 4.9G(4.9G), 6.1G(6.1G), 9.8G(9.8G) 0~63 characters 0~63 characters

1.25G~1, 2.5G~2, 3.0G~4, 4.9G~8, 6.1G~16, 9.8G~32

bit/s

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

N/A N/A

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Enumeration Type

LOCKED(Locked), LOCKED~0, UNLOCKED(Unlock UNLOCKED~1 ed)

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

15~100

N/A

0.1

None

Interval Type

15~30

N/A

0.1

None

Interval Type

0~7

N/A

None

None

Interval Type

0~249

N/A

None

None

Enumeration Type

TRUNK(TRUNK)

TRUNK~0

None

None

Enumeration Type

TD_SCDMA(TD_S CDMA), LTE_TDD(LTE_TD D), TDS_TDL(TDS_TD L), LTE_FDD(LTE_FD D), WiMAX_LTE(WiMA X_LTE), CDMA_LTE(CDMA _LTE), GSM_LTE(GSM_L TE), UMTS_ONLY(UMT S_ONLY), UMTS_LTE(UMTS_ LTE)

TD_SCDMA~2, LTE_TDD~4, TDS_TDL~6, LTE_FDD~8, WiMAX_LTE~20, None CDMA_LTE~40, GSM_LTE~72, UMTS_ONLY~128, UMTS_LTE~136

None

Interval Type

0~8

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~500

N/A

0.1dBm

None

Interval Type

0~65535

N/A

0.1dB

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

0~6

N/A

None

None

Character String Type

0~24 characters LO_TD(LO_TD), TL(TL), LO(LO), WO(WO), WL(WL), C0(C0), CL(CL), CW(CW), CWL(CWL), GO(GO), GL(GL), GW(GW), GWL(GWL), GC(GC), GCL(GCL), GCW(GCW), GCWL(GCWL), UO(UO), UL(UL), UW(UW), UWL(UWL), UC(UC), UCL(UCL), UCW(UCW), UCWL(UCWL), GU(GU), UGL(UGL), UGW(UGW), UGWL(UGWL), UGC(UGC), UGCL(UGCL), UGCW(UGCW), UGCWL(UGCWL), NULL(Invalid) CONNECTHEAD(A ccess from chain head or ring head), CONNECTTAIL(Ac cess from ring tail), CONNECTBOTH(A ccess from both ends of the ring), SEPERATEBYBRE AK(Seperated by break points), LINKDOWN(Link down)

N/A

None

None

Enumeration Type

LO_TD~4, TL~6, LO~8, WO~16, WL~20, C0~32, CL~40, CW~48, CWL~56, GO~64, GL~72, GW~80, GWL~88, GC~96, GCL~104, GCW~112, GCWL~120, UO~128, UL~136, UW~144, None UWL~152, UC~160, UCL~168, UCW~176, UCWL~184, GU~192, UGL~200, UGW~208, UGWL~216, UGC~224, UGCL~232, UGCW~240, UGCWL~248, NULL~255

None

Enumeration Type

CONNECTHEAD~0 , CONNECTTAIL~1, CONNECTBOTH~2 None , SEPERATEBYBRE AK~3, LINKDOWN~4

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~4294967295

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

1~60

N/A

min

None

Enumeration Type

POW_IQ_MODE(P OW_IQ_MODE), POW_IQ_MODE~0 POW_MODE(POW , POW_MODE~1, None _MODE), IQ_MODE~2 IQ_MODE(IQ_MOD E)

None

Interval Type

9~18

N/A

None

Enumeration Type

HALFSECOND(HA LFSECOND), ONESECOND(ONE SECOND), TWOSECOND(TW OSECOND), THREESECOND(T HREESECOND), FOURSECOND(FO URSECOND), FIVESECOND(FIV ESECOND) 0~65535 0~31 characters SUCCESS(SUCCE SS), FAILURE(FAILURE ), UNKNOWTYPE(Un know Type)

HALFSECOND~5, ONESECOND~10, TWOSECOND~20, THREESECOND~3 None 0, FOURSECOND~40 , FIVESECOND~50

None None

Interval Type Character String Type

N/A N/A

None None

None

Enumeration Type

SUCCESS~0, FAILURE~1, None UNKNOWTYPE~25 5

None

Enumeration Type

USERDEFINE(USE RDEFINE), USERDEFINE~0, DEFAULT(DEFAUL DEFAULT~1 T) 0~1000000000 N/A

None

None

Interval Type

0.000000001

None

Enumeration Type

1.25G(1.25G), 2.5G(2.5G), 3.0G(3.0G), 4.9G(4.9G), 6.1G(6.1G), 9.8G(9.8G) Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

1.25G~1, 2.5G~2, 3.0G~4, 4.9G~8, 6.1G~16, 9.8G~32

bit/s

None

Enumeration Type

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters

N/A

None

None

Enumeration Type

UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295 CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP) 0~63 characters 0~63 characters

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4 N/A N/A

None

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

MRFU(MRFU), LRFU(LRFU)

MRFU~16, LRFU~12304

None

None

Enumeration Type

LOCKED(Locked), LOCKED~0, UNLOCKED(Unlock UNLOCKED~1 ed) Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical) Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP)

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

15~100

N/A

0.1

None

Interval Type

15~30

N/A

0.1

None

Interval Type

0~7

N/A

None

None

Interval Type

0~249

N/A

None

None

Enumeration Type

TRUNK(TRUNK)

TRUNK~0

None

None

Enumeration Type

TD_SCDMA(TD_S CDMA), LTE_TDD(LTE_TD D), TDS_TDL(TDS_TD L), LTE_FDD(LTE_FD D), WiMAX_LTE(WiMA X_LTE), CDMA_LTE(CDMA _LTE), GSM_LTE(GSM_L TE), UMTS_ONLY(UMT S_ONLY), UMTS_LTE(UMTS_ LTE)

TD_SCDMA~2, LTE_TDD~4, TDS_TDL~6, LTE_FDD~8, WiMAX_LTE~20, None CDMA_LTE~40, GSM_LTE~72, UMTS_ONLY~128, UMTS_LTE~136

None

Interval Type

0~8

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~500

N/A

0.1dBm

None

Interval Type

0~65535

N/A

0.1dB

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

0~6

N/A

None

None

Character String Type

0~24 characters LO_TD(LO_TD), TL(TL), LO(LO), WO(WO), WL(WL), C0(C0), CL(CL), CW(CW), CWL(CWL), GO(GO), GL(GL), GW(GW), GWL(GWL), GC(GC), GCL(GCL), GCW(GCW), GCWL(GCWL), UO(UO), UL(UL), UW(UW), UWL(UWL), UC(UC), UCL(UCL), UCW(UCW), UCWL(UCWL), GU(GU), UGL(UGL), UGW(UGW), UGWL(UGWL), UGC(UGC), UGCL(UGCL), UGCW(UGCW), UGCWL(UGCWL), NULL(Invalid) CONNECTHEAD(A ccess from chain head or ring head), CONNECTTAIL(Ac cess from ring tail), CONNECTBOTH(A ccess from both ends of the ring), SEPERATEBYBRE AK(Seperated by break points), LINKDOWN(Link down)

N/A

None

None

Enumeration Type

LO_TD~4, TL~6, LO~8, WO~16, WL~20, C0~32, CL~40, CW~48, CWL~56, GO~64, GL~72, GW~80, GWL~88, GC~96, GCL~104, GCW~112, GCWL~120, UO~128, UL~136, UW~144, None UWL~152, UC~160, UCL~168, UCW~176, UCWL~184, GU~192, UGL~200, UGW~208, UGWL~216, UGC~224, UGCL~232, UGCW~240, UGCWL~248, NULL~255

None

Enumeration Type

CONNECTHEAD~0 , CONNECTTAIL~1, CONNECTBOTH~2 None , SEPERATEBYBRE AK~3, LINKDOWN~4

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~4294967295

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

1~60

N/A

min

None

Enumeration Type

POW_IQ_MODE(P OW_IQ_MODE), POW_IQ_MODE~0 POW_MODE(POW , POW_MODE~1, None _MODE), IQ_MODE~2 IQ_MODE(IQ_MOD E)

None

Interval Type

9~18

N/A

None

Enumeration Type

HALFSECOND(HA LFSECOND), ONESECOND(ONE SECOND), TWOSECOND(TW OSECOND), THREESECOND(T HREESECOND), FOURSECOND(FO URSECOND), FIVESECOND(FIV ESECOND) 0~65535 0~31 characters SUCCESS(SUCCE SS), FAILURE(FAILURE ), UNKNOWTYPE(Un know Type)

HALFSECOND~5, ONESECOND~10, TWOSECOND~20, THREESECOND~3 None 0, FOURSECOND~40 , FIVESECOND~50

None None

Interval Type Character String Type

N/A N/A

None None

None

Enumeration Type

SUCCESS~0, FAILURE~1, None UNKNOWTYPE~25 5

None

Enumeration Type

USERDEFINE(USE RDEFINE), USERDEFINE~0, DEFAULT(DEFAUL DEFAULT~1 T) 0~1000000000 N/A

None

None

Interval Type

0.000000001

None

Enumeration Type

1.25G(1.25G), 2.5G(2.5G), 3.0G(3.0G), 4.9G(4.9G), 6.1G(6.1G), 9.8G(9.8G) 0~63 characters 0~63 characters

1.25G~1, 2.5G~2, 3.0G~4, 4.9G~8, 6.1G~16, 9.8G~32

bit/s

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

N/A N/A

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0 N/A

None

None

Interval Type

60~254

N/A

None

None

Interval Type

0 N/A

None

None

Character String Type

0~31 characters

N/A

None

None

Enumeration Type

MRRU(MRRU), PRRU(PRRU), LRRU(LRRU)

MRRU~15, PRRU~271, LRRU~12303

None

None None

Enumeration Type Interval Type

PIMOFFLINE(PIMO PIMOFFLINE~0 FFLINE) 120~300 N/A

None s

None

Interval Type

5~20

N/A

dB

None

Interval Type

0~1

N/A

None

None

Enumeration Type

IsInerefered(It is Interfered), IsInerefered~0, IsNotInterfered(It is IsNotInterfered~1 not interfered) 0~4294967295 0~4294967295 N/A N/A

None

None None

Interval Type Interval Type

dB dB

None

Interval Type

0~4294967295

N/A

dB

None

Enumeration Type

LOCKED(Locked), LOCKED~0, UNLOCKED(Unlock UNLOCKED~1 ed)

None

None

Enumeration Type

Alarm_0(Normal), Alarm_1(Warning), Alarm_2(Minor), Alarm_3(Minor), Alarm_4(Major), Alarm_5(Major), Alarm_6(Major), Alarm_7(Major), Alarm_8(Critical), Alarm_9(Critical), Alarm_10(Critical), Alarm_11(Critical), Alarm_12(Critical), Alarm_13(Critical), Alarm_14(Critical), Alarm_15(Critical)

Alarm_0~0, Alarm_1~1, Alarm_2~2, Alarm_3~3, Alarm_4~4, Alarm_5~5, Alarm_6~6, Alarm_7~7, Alarm_8~8, Alarm_9~9, Alarm_10~10, Alarm_11~11, Alarm_12~12, Alarm_13~13, Alarm_14~14, Alarm_15~15

None

None

Enumeration Type

Enabled(Enabled), Enabled~0, Disabled(Disabled) Disabled~1

None

None

Enumeration Type

Avail_0(Normal), Avail_1(Fault), Avail_20(In test), Avail_21(Fault, In test), Avail_500(Starting up), Avail_501(Starting up, Fault), Avail_504(Unconfig ured), Avail_508(Inconsist ent), Avail_509(Inconsist ent, Fault), Avail_520(Starting up,In test), Avail_521(Starting up, Fault, In test), Avail_524(Unconfig ured,In test), Avail_528(Inconsist ent,In test), Avail_529(Inconsist ent, Fault, In test), Avail_800(Communi cation lost), Avail_801(Fault, Communication lost), Avail_820(Communi cation lost, In test), Avail_821(Fault, Communication

Avail_0~0, Avail_1~1, Avail_20~32, Avail_21~33, Avail_500~1280, Avail_501~1281, Avail_504~1284, Avail_508~1288, Avail_509~1289, Avail_520~1312, Avail_521~1313, Avail_524~1316, Avail_528~1320, Avail_529~1321, Avail_800~2048, Avail_801~2049, Avail_820~2080, Avail_821~2081, Avail_c10~3088, Avail_c11~3089, Avail_c12~3090, Avail_c13~3091, Avail_c14~3092, Avail_c30~3120, Avail_c31~3121, Avail_c32~3122, Avail_c33~3123, Avail_c34~3124, Avail_d00~3328, Avail_d01~3329, Avail_d04~3332, Avail_d08~3336, Avail_d09~3337, Avail_d20~3360,

None

None

Character String Type

0~2047 characters

N/A

None

None None

Character String Type Character String Type

0~31 characters 0~31 characters

N/A N/A

None None

None

Character String Type

0~259 characters

N/A

None

None

Character String Type

0~11 characters

N/A

None

None

Character String Type Character String Type

0~23 characters

N/A

None

None

0~19 characters UMPT(UMPT), FAN(FAN), UPEU(UPEU), PMU(PMU), PSU(PSU), BAT(BAT), TCU(TCU), EMU(EMU), UTRP(UTRP), USCU(USCU), UEIU(UEIU), FMU(FMU), MRRU(MRRU), MRFU(MRFU), RHUB(RHUB), UBRI(UBRI), MRXU(MRXU), MTXU(MTXU), UCIU(UCIU), CCU(CCU), MAAU(MAAU), UNKNOWN(UNKN OWN), PRRU(PRRU), GRRU(GRRU), GRFU(GRFU), GATM(GATM), DRRU(DRRU), DRFU(DRFU), WRFU(WRFU), NGRU(NGRU), LMPT(LMPT), LBBP(LBBP), LRRU(LRRU), 0~4294967295 0~4294967295

N/A

None

None

Enumeration Type

UMPT~1, FAN~3, UPEU~4, PMU~5, PSU~6, BAT~7, TCU~8, EMU~10, UTRP~11, USCU~12, UEIU~13, FMU~14, MRRU~15, MRFU~16, RHUB~17, UBRI~20, MRXU~22, MTXU~23, UCIU~24, CCU~25, MAAU~35, UNKNOWN~254, None PRRU~271, GRRU~4111, GRFU~4112, GATM~4114, DRRU~4367, DRFU~4368, WRFU~8208, NGRU~8211, LMPT~12289, LBBP~12290, LRRU~12303, LRFU~12304, BRFU~16400, CRFU~20496, RRU~24591

None None

Interval Type Interval Type

N/A N/A

% None

None

Enumeration Type

CPU(CPU), DSP(DSP), SLAVE_CPU(Slave CPU), MDU_CPU(MDU_C PU), MRU_CPU(MRU_C PU)

CPU~1, DSP~2, SLAVE_CPU~3, MDU_CPU~4, MRU_CPU~5

None

None

Interval Type

None None

Interval Type Character String Type

2147483648~21474 N/A 83647 2147483648~21474 N/A 83647 0~255 characters N/A

degree Celsius

degree Celsius None

None

Enumeration Type

Master(Master), NDD(NDD), NCD(NCD), NDC(NDC), NEC(NEC), EUL(EUL), EDL(EDL), Slave(Slave)

Master~0, NDD~1, NCD~2, NDC~3, NEC~4, EUL~5, EDL~6, Slave~7

None

None

Enumeration Type

CABINET(CABINE T), SUBRACK(SUBRA CK), BOARD(BOARD), SUBBOARD(SUBB OARD), SFP(SFP)

CABINET~0, SUBRACK~1, BOARD~2, SUBBOARD~3, SFP~4

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

15~100

N/A

0.1

None

Interval Type

15~30

N/A

0.1

None

Interval Type

0~7

N/A

None

None

Interval Type

0~249

N/A

None

None

Enumeration Type

TRUNK(TRUNK)

TRUNK~0

None

None

Enumeration Type

TD_SCDMA(TD_S CDMA), LTE_TDD(LTE_TD D), TDS_TDL(TDS_TD L), LTE_FDD(LTE_FD D), WiMAX_LTE(WiMA X_LTE), CDMA_LTE(CDMA _LTE), GSM_LTE(GSM_L TE), UMTS_ONLY(UMT S_ONLY), UMTS_LTE(UMTS_ LTE)

TD_SCDMA~2, LTE_TDD~4, TDS_TDL~6, LTE_FDD~8, WiMAX_LTE~20, None CDMA_LTE~40, GSM_LTE~72, UMTS_ONLY~128, UMTS_LTE~136

None

Interval Type

0~8

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~500

N/A

0.1dBm

None

Interval Type

0~65535

N/A

0.1dB

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

-100~200

N/A

degree Celsius

None

Interval Type

0~6

N/A

None

None

Character String Type

0~24 characters LO_TD(LO_TD), TL(TL), LO(LO), WO(WO), WL(WL), C0(C0), CL(CL), CW(CW), CWL(CWL), GO(GO), GL(GL), GW(GW), GWL(GWL), GC(GC), GCL(GCL), GCW(GCW), GCWL(GCWL), UO(UO), UL(UL), UW(UW), UWL(UWL), UC(UC), UCL(UCL), UCW(UCW), UCWL(UCWL), GU(GU), UGL(UGL), UGW(UGW), UGWL(UGWL), UGC(UGC), UGCL(UGCL), UGCW(UGCW), UGCWL(UGCWL), NULL(Invalid) CONNECTHEAD(A ccess from chain head or ring head), CONNECTTAIL(Ac cess from ring tail), CONNECTBOTH(A ccess from both ends of the ring), SEPERATEBYBRE AK(Seperated by break points), LINKDOWN(Link down)

N/A

None

None

Enumeration Type

LO_TD~4, TL~6, LO~8, WO~16, WL~20, C0~32, CL~40, CW~48, CWL~56, GO~64, GL~72, GW~80, GWL~88, GC~96, GCL~104, GCW~112, GCWL~120, UO~128, UL~136, UW~144, None UWL~152, UC~160, UCL~168, UCW~176, UCWL~184, GU~192, UGL~200, UGW~208, UGWL~216, UGC~224, UGCL~232, UGCW~240, UGCWL~248, NULL~255

None

Enumeration Type

CONNECTHEAD~0 , CONNECTTAIL~1, CONNECTBOTH~2 None , SEPERATEBYBRE AK~3, LINKDOWN~4

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~4294967295

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

1~60

N/A

min

None

Enumeration Type

POW_IQ_MODE(P OW_IQ_MODE), POW_IQ_MODE~0 POW_MODE(POW , POW_MODE~1, None _MODE), IQ_MODE~2 IQ_MODE(IQ_MOD E)

None

Interval Type

9~18

N/A

None

Enumeration Type

HALFSECOND(HA LFSECOND), ONESECOND(ONE SECOND), TWOSECOND(TW OSECOND), THREESECOND(T HREESECOND), FOURSECOND(FO URSECOND), FIVESECOND(FIV ESECOND) 0~65535 0~31 characters SUCCESS(SUCCE SS), FAILURE(FAILURE ), UNKNOWTYPE(Un know Type)

HALFSECOND~5, ONESECOND~10, TWOSECOND~20, THREESECOND~3 None 0, FOURSECOND~40 , FIVESECOND~50

None None

Interval Type Character String Type

N/A N/A

None None

None

Enumeration Type

SUCCESS~0, FAILURE~1, None UNKNOWTYPE~25 5

None

Enumeration Type

USERDEFINE(USE RDEFINE), USERDEFINE~0, DEFAULT(DEFAUL DEFAULT~1 T) 0~1000000000 N/A

None

None

Interval Type

0.000000001

None

Enumeration Type

1.25G(1.25G), 2.5G(2.5G), 3.0G(3.0G), 4.9G(4.9G), 6.1G(6.1G), 9.8G(9.8G) 0~63 characters 0~63 characters

1.25G~1, 2.5G~2, 3.0G~4, 4.9G~8, 6.1G~16, 9.8G~32

bit/s

None None

Character String Type Character String Type Character String Type Character String Type Character String Type Enumeration Type

N/A N/A

None None

None

0~63 characters

N/A

None

None None

0~63 characters 1~39 characters Normal(Normal), Fault(Fault), Timeout(Timeout), NULL(NULL)

N/A N/A

None None

None

Normal~0, Fault~1, Timeout~2, None NULL~4294967295

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~249

N/A

None

None

Enumeration Type

CHAIN(CHAIN), RING(RING), LOADBALANCE(L OADBALANCE)

CHAIN~0, RING~1, None LOADBALANCE~2

None

Enumeration Type

COLD(COLD), HOT(HOT)

COLD~0, HOT~1

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~5

N/A

None

None

Interval Type

0~5

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~5

N/A

None

None

Interval Type

0~5

N/A

None

None

Interval Type

0~8,255

N/A

None

None

Interval Type

0~8,255

N/A

None

None

Enumeration Type

LOCALPORT(local port), LOCALPORT~0, PEERPORT(peer PEERPORT~1 port)

None

None

Enumeration Type

1.25G(1.25), 2.5G(2.5), 4.9G(4.9), 6.1G(6.1), 9.8G(9.8), AUTO(Auto)

1.25G~0, 2.5G~1, 4.9G~3, 6.1G~4, Gbit/s 9.8G~5, AUTO~255

None

Interval Type

0~3

N/A

None

None

Interval Type

0~3

N/A

None

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

0~44

N/A

0.5dB

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~62

N/A

None

None

Interval Type

4~5,60~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

100~2500

N/A

0.01

None

Enumeration Type

ON(ON), OFF(OFF) ON~0, OFF~1

None

None

Interval Type

-100~10

N/A

0.1dB

None

Interval Type

0~65535

N/A

0.2MHz

None

Interval Type

30~130

N/A

0.1dB

None None None

Interval Type Interval Type Interval Type

20~30 0~65535 0~65535

N/A N/A N/A

s None None

None

Character String Type

0~63 characters

N/A

None

None

Interval Type

0,500~65500

N/A

10mW

None

Interval Type

0,500~65500

N/A

10mW

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Interval Type

0~4294967295

N/A

0.1dBm

None

Interval Type

0,500~65500

N/A

10mW

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Interval Type

0~4294967295

N/A

0.1MHz

None

Character String Type

0~31 characters

N/A

MHz

None

Interval Type

0~65535

N/A

0.1MHz

None

Interval Type

0~65535

N/A

0.1MHz

None

Enumeration Type

Normal(Normal), Normal~0, Unknown(Unknown) Unknown~1, , Crossed(Crossed) Crossed~2 Valid IP address N/A

None

None

IP Address Type

None

None

Interval Type

1~525600

N/A

min

None

Interval Type

123~5999,6100~65 N/A 534

None

None

Enumeration Type

IPV4(IPv4), IPV6(IPv6)

IPV4~0, IPV6~1

None

None

IP Address Type

Valid IP address PLAIN(Plain), DES_S(DES_S), DES_N(DES_N), DES_A(DES_A), MD5(MD5)

N/A

None

None

Enumeration Type

PLAIN~0, DES_S~1, DES_N~2, DES_A~3, MD5~4

None

None

Password Type

1~16 characters

N/A

None

None

Interval Type

1~4294967295

N/A

None

None

Enumeration Type

Slaver(Slave), Master(Master)

Slaver~0, Master~1 None

None

Enumeration Type

GMT-1200(GMT12:00), GMT1100(GMT-11:00), GMT-1000(GMT10:00), GMT0930(GMT-09:30), GMT-0900(GMT09:00), GMT0800(GMT-08:00), GMT-0700(GMT07:00), GMT0600(GMT-06:00), GMT-0500(GMT05:00), GMT0430(GMT-04:30), GMT-0400(GMT04:00), GMT0330(GMT-03:30), GMT-0300(GMT03:00), GMT0200(GMT-02:00), GMT-0100(GMT01:00), GMT(GMT), GMT+0100(GMT+0 1:00), GMT+0200(GMT+0 2:00), GMT+0300(GMT+0 3:00), GMT+0330(GMT+0 3:30), GMT+0400(GMT+0 4:00), GMT+0430(GMT+0 NO(No), YES(Yes)

GMT-1200~0, GMT1100~4, GMT1000~8, GMT0930~10, GMT0900~12, GMT0800~16, GMT0700~20, GMT0600~24, GMT0500~28, GMT0430~30, GMT0400~32, GMT0330~34, GMT0300~36, GMT0200~40, GMT0100~44, GMT~48, GMT+0100~52, GMT+0200~56, None GMT+0300~60, GMT+0330~62, GMT+0400~64, GMT+0430~66, GMT+0500~68, GMT+0530~70, GMT+0545~71, GMT+0600~72, GMT+0630~74, GMT+0700~76, GMT+0800~80, GMT+0845~83, GMT+0900~84, GMT+0930~86, GMT+1000~88, GMT+1030~90, GMT+1100~92, NO~0, YES~1 None

None

Enumeration Type

None

Enumeration Type

DATE(Date mode), WEEK(Week DATE~0, WEEK~1, mode), None DATEWEEK~2 DATEWEEK(Date and week mode)

None

Enumeration Type

JAN(January), FEB(February), MAR(March), APR(April), MAY(May), JUN(June), JUL(July), AUG(August), SEP(September), OCT(October), NOV(November), DEC(December)

JAN~1, FEB~2, MAR~3, APR~4, MAY~5, JUN~6, JUL~7, AUG~8, SEP~9, OCT~10, NOV~11, DEC~12

None

None

Interval Type

1~31

N/A

None

None

Enumeration Type

LAST(Last), FIRST(First), SECOND(Second), THIRD(Third), FOURTH(Fourth) MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday), SUN(Sunday)

LAST~0, FIRST~1, SECOND~2, None THIRD~3, FOURTH~4

None

Enumeration Type

MON~1, TUE~2, WED~3, THU~4, FRI~5, SAT~6, SUN~7

None

None

Compound Type

00:00:00~23:59:59

N/A

None

None

Enumeration Type

DATE(Date mode), WEEK(Week DATE~0, WEEK~1, mode), None DATEWEEK~2 DATEWEEK(Date and week mode)

None

Enumeration Type

JAN(January), FEB(February), MAR(March), APR(April), MAY(May), JUN(June), JUL(July), AUG(August), SEP(September), OCT(October), NOV(November), DEC(December)

JAN~1, FEB~2, MAR~3, APR~4, MAY~5, JUN~6, JUL~7, AUG~8, SEP~9, OCT~10, NOV~11, DEC~12

None

None

Interval Type

1~31

N/A

None

None

Enumeration Type

LAST(Last), FIRST(First), SECOND(Second), THIRD(Third), FOURTH(Fourth) MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday), SUN(Sunday)

LAST~0, FIRST~1, SECOND~2, None THIRD~3, FOURTH~4

None

Enumeration Type

MON~1, TUE~2, WED~3, THU~4, FRI~5, SAT~6, SUN~7

None

None

Compound Type

00:00:00~23:59:59

N/A

None

None

Interval Type

-120~120

N/A

min

None

Interval Type

-720~840

N/A

min

None

Compound Type

2000-01-01~203312-31

N/A

None

None

Compound Type

00:00:00~23:59:59

N/A

None

None

Compound Type

None

N/A

None

None

Enumeration Type

NTP(NTP), GPS(GPS), NONE(None)

NTP~0, GPS~1, NONE~2

None

None

Character String Type

0~30 characters

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

21~65535

N/A

None

None

Interval Type

0~3

N/A

None

None

Interval Type

10~254

N/A

None

Service based interRAT handover to UTRAN Interval Type Service based interRAT handover to GERAN

0~9

N/A

None

Service Based InterInterval Type frequency Handover

0~9

N/A

None

None

Interval Type

0~3

N/A

None

None

Enumeration Type

QCI1(QCI 1), QCI2(QCI 2), QCI3(QCI 3), QCI4(QCI 4), QCI5(QCI 5), QCI6(QCI 6), QCI7(QCI 7), QCI8(QCI 8), QCI9(QCI 9)

QCI1~1, QCI2~2, QCI3~3, QCI4~4, QCI5~5, QCI6~6, QCI7~7, QCI8~8, QCI9~9

None

Service based interRAT handover to UTRAN Interval Type Service based interRAT handover to GERAN

0~9

N/A

None

Service Based InterInterval Type frequency Handover

0~9

N/A

None

None

Interval Type

0~3

N/A

None

CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT CS Fallback with LAI to UTRAN CS Fallback with LAI to GERAN Flash CS Fallback to UTRAN Flash CS Fallback Enumeration Type to GERAN PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000

UTRAN, GERAN, CDMA2000

UTRAN~0, GERAN~1, CDMA2000~2

None

UTRAN, GERAN, CDMA2000, NULL

UTRAN~0, GERAN~1, CDMA2000~2, NULL~3

None

CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 CS Fallback to UTRAN LoCation Services(LCS)

UTRAN, GERAN, CDMA2000, NULL

UTRAN~0, GERAN~1, CDMA2000~2, NULL~3

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

CS Fallback to GERAN LoCation Services(LCS)

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

CS Fallback to CDMA2000 1xRTT Enumeration Type LoCation Services(LCS)

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Interval Type

0~3

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000

Character String Type

3 characters

N/A

None

Character String Type

2~3 characters

N/A

None

Intra-LTE Load Balancing Inter-RAT Load Interval Type Sharing to UTRAN Inter-RAT Load Sharing to GERAN

0~255

N/A

None

Intra-LTE Load Balancing Inter-RAT Load Enumeration Type Sharing to UTRAN Inter-RAT Load Sharing to GERAN

LTE, UTRAN, GERAN

LTE~0, UTRAN~1, None GERAN~2

Intra-LTE Load Balancing Inter-RAT Load Interval Type Sharing to UTRAN Inter-RAT Load Sharing to GERAN

0~45589,64436~65 N/A 535

None

Inter-RAT Load Sharing to UTRAN Interval Type Inter-RAT Load Sharing to GERAN

0~7

N/A

None

Intra-LTE Load Balancing Inter-RAT Load Enumeration Type Sharing to UTRAN Inter-RAT Load Sharing to GERAN

GSM_dcs1800, GSM_pcs1900

GSM_dcs1800~0, GSM_pcs1900~1

None

Service Based InterInterval Type frequency Handover

0~3

N/A

None

Service Based InterInterval Type frequency Handover

0~9

N/A

None

Service Based InterEnumeration Type frequency Handover

NO_HO, PERMIT_HO

NO_HO~0, PERMIT_HO~1

None

Service Based InterInterval Type frequency Handover

0~45589,64436~65 N/A 535

None

Service based interRAT handover to UTRAN Interval Type Service based interRAT handover to GERAN

0~3

N/A

None

Service based interRAT handover to UTRAN Interval Type Service based interRAT handover to GERAN

0~9

N/A

None

Service based interRAT handover to UTRAN Enumeration Type Service based interRAT handover to GERAN

NO_HO, PERMIT_HO, MUST_HO

NO_HO~0, PERMIT_HO~1, MUST_HO~2

None

Intra-LTE Load Balancing Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN Interval Type Flexible User Steering Camp & Handover Based on SPID UL Pre-allocation Based on SPID

1~256

N/A

None

DRX

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

Intra-LTE Load Balancing Inter-RAT Load Enumeration Type Sharing to UTRAN Inter-RAT Load Sharing to GERAN Intra-LTE Load Balancing Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN Interval Type Flexible User Steering Camp & Handover Based on SPID UL Pre-allocation Based on SPID

NOT_CFG(NOT_C NOT_CFG~0, FG), CFG(CFG) CFG~1

None

0~255

N/A

None

UL Pre-allocation Based on SPID

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

Intra-LTE Load Balancing

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

Intra-LTE Load Balancing

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

Intra-LTE Load Balancing

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

Integrity Protection

Interval Type

0,10~600

N/A

Integrity Protection

Interval Type

0,128~4294967295 N/A

None

Integrity Protection

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Encryption: AES Encryption: SNOW Enumeration Type 3G

NULL(NULL Algorithm), Snow3G(SNOW 3G NULL~0, None Algorithm), Snow3G~1, AES~2 AES(AES Algorithm)

Encryption: AES Encryption: SNOW Enumeration Type 3G

NULL(NULL Algorithm), Snow3G(SNOW 3G NULL~0, None Algorithm), Snow3G~1, AES~2 AES(AES Algorithm)

Encryption: AES Encryption: SNOW Enumeration Type 3G

NULL(NULL Algorithm), Snow3G(SNOW 3G NULL~0, None Algorithm), Snow3G~1, AES~2 AES(AES Algorithm)

None

Interval Type

10~200

N/A

None

Interval Type

10~200

N/A

None

Interval Type

10~200

N/A

Integrity Protection

Enumeration Type

NULL(NULL Algorithm), Snow3G(SNOW 3G NULL~0, None Algorithm), Snow3G~1, AES~2 AES(AES Algorithm)

Integrity Protection

Enumeration Type

NULL(NULL Algorithm), Snow3G(SNOW 3G NULL~0, None Algorithm), Snow3G~1, AES~2 AES(AES Algorithm)

Integrity Protection

Enumeration Type

NULL(NULL Algorithm), Snow3G(SNOW 3G NULL~0, None Algorithm), Snow3G~1, AES~2 AES(AES Algorithm)

Mobility Management Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Mobility Management Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Enumeration Type

X2_OVER_M2000( X2SonLink is set up over M2000), X2_OVER_M2000~ None X2_OVER_S1(X2S 0, X2_OVER_S1~1 onLink is set up over S1)

Enhanced Scheduling

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

LCG_PROFILE_0, LCG_PROFILE_1

LCG_PROFILE_0~ 0, None LCG_PROFILE_1~ 1

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

OFF(Off), ON(On)

OFF~0, ON~1

None

RRC Connection Management

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

RObust Header Compression (ROHC)

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

RObust Header Compression (ROHC)

Enumeration Type

U_MODE(Unidirecti onal Mode), O_MODE(BiU_MODE~1, directional O_MODE~2, Optimistic Mode), R_MODE~3 R_MODE(BiDirectional Reliable Mode)

None

RObust Header Compression (ROHC)

Bit Field Type

Profile0x0001(Profil e0x0001), Profile0x0002(Profil e0x0002), Profile0x0003(Profil e0x0003), Profile0x0004(Profil e0x0004)

Profile0x0001~0, Profile0x0002~1, Profile0x0003~2, Profile0x0004~3

None

RRC Connection Management

Interval Type

1~16

N/A

Mobility Management Cell Selection and Re-selection

Enumeration Type

min5(5), min10(10), min20(20), min30(30), min60(60), min120(120), min180(180)

min5~0, min10~1, min20~2, min30~3, min60~4, min min120~5, min180~6

Mobility Management Cell Selection and Re-selection

Enumeration Type

ms50(50), ms100(100), ms150(150), ms200(200), ms500(500), ms1000(1000), ms2000(2000)

ms50~0, ms100~1, ms150~2, ms200~3, ms ms500~4, ms1000~5, ms2000~6

Mobility Management Cell Selection and Re-selection

Enumeration Type

ms100(100), ms200(200), ms500(500), ms1000(1000), ms2000(2000), ms4000(4000), ms8000(8000)

ms100~0, ms200~1, ms500~2, ms1000~3, ms2000~4, ms4000~5, ms8000~6

ms

Mobility Management Cell Selection and Re-selection

Enumeration Type

min5(5), min10(10), min20(20), min30(30), min60(60), min120(120), min180(180)

min5~0, min10~1, min20~2, min30~3, min60~4, min min120~5, min180~6

RRC Connection Management

Interval Type

0~3600

N/A

RRC Connection Management

Interval Type

0~3600

N/A

None

Interval Type

0~255

N/A

None

None

Enumeration Type

IPv4(IPv4 Address), IPv4~0, IPv6~1 IPv6(IPv6 Address)

None

None

IP Address Type

Valid IP address

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

0~17

N/A

None

Dynamic Downlink Power Allocation

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Dynamic Downlink Power Allocation

Enumeration Type

DB_6_P_A(-6 dB), DB_4DOT77_P_A(4.77 dB), DB_3_P_A(-3 dB), DB_1DOT77_P_A(1.77 dB), DB0_P_A(0 dB), DB1_P_A(1 dB), DB2_P_A(2 dB), DB3_P_A(3 dB)

DB_6_P_A~0, DB_4DOT77_P_A~ 1, DB_3_P_A~2, DB_1DOT77_P_A~ dB 3, DB0_P_A~4, DB1_P_A~5, DB2_P_A~6, DB3_P_A~7

None

Interval Type

0~17

N/A

None

DRX

Interval Type

0~999

N/A

per mill

DRX

Interval Type

1~1000

N/A

per mill

DRX

Interval Type

0~1999

N/A

per mill

DRX

Interval Type

1~2000

N/A

per mill

DRX

Interval Type

0~1999

N/A

per mill

DRX

Interval Type

1~2000

N/A

per mill

DRX

Interval Type

2~300

N/A

20ms

None

Interval Type

0~17

N/A

None

Uplink Power Control

Enumeration Type

UU_DISABLE(Disa ble), UU_DISABLE~0, UU_ENABLE(Enabl UU_ENABLE~1 e)

None

Uplink Power Control

Interval Type

-105,-90,-75,-60,45,-30,N/A 15,0,15,30,45,60,75 ,90,105,120

0.1dB

Uplink Power Control

Interval Type

-30,-20,10,0,10,20,30,40,50 N/A ,60,70,80,90,100,11 0,120

0.1dB

Uplink Power Control

Enumeration Type

UU_FC0_FILTER_ COEFF(UU_FC0_F ILTER_COEFF), UU_FC1_FILTER_ COEFF(UU_FC1_F ILTER_COEFF), UU_FC2_FILTER_ COEFF(UU_FC2_F ILTER_COEFF), UU_FC3_FILTER_ COEFF(UU_FC3_F ILTER_COEFF), UU_FC4_FILTER_ COEFF(UU_FC4_F ILTER_COEFF), UU_FC5_FILTER_ COEFF(UU_FC5_F ILTER_COEFF), UU_FC6_FILTER_ COEFF(UU_FC6_F ILTER_COEFF), UU_FC7_FILTER_ COEFF(UU_FC7_F ILTER_COEFF), UU_FC8_FILTER_ COEFF(UU_FC8_F ILTER_COEFF), UU_FC9_FILTER_ COEFF(UU_FC9_F ILTER_COEFF), UU_FC11_FILTER_ COEFF(UU_FC11_ FILTER_COEFF), UU_FC13_FILTER_

UU_FC0_FILTER_ COEFF~0, UU_FC1_FILTER_ COEFF~1, UU_FC2_FILTER_ COEFF~2, UU_FC3_FILTER_ COEFF~3, UU_FC4_FILTER_ COEFF~4, UU_FC5_FILTER_ COEFF~5, UU_FC6_FILTER_ COEFF~6, UU_FC7_FILTER_ None COEFF~7, UU_FC8_FILTER_ COEFF~8, UU_FC9_FILTER_ COEFF~9, UU_FC11_FILTER_ COEFF~10, UU_FC13_FILTER_ COEFF~11, UU_FC15_FILTER_ COEFF~12, UU_FC17_FILTER_ COEFF~13, UU_FC19_FILTER_ COEFF~14

None

Interval Type

0~17

N/A

None

Distance based Inter-RAT handover to UTRAN Distance based Inter-RAT handover Bit Field Type to GERAN Distance Based Inter-frequency Handover

EUTRAN~0, EUTRAN, GERAN, GERAN~1, UTRAN UTRAN~2

None

Distance Based Inter-frequency Handover Distance based Inter-RAT handover Interval Type to UTRAN Distance based Inter-RAT handover to GERAN

1~1000

N/A

100m

None

Interval Type

0~17

N/A

None

None

Interval Type

0~9

N/A

None

DRX

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

DRX

Enumeration Type

PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 subframes), PSF6(6 subframes), PSF8(8 subframes), PSF10(10 subframes), PSF20(20 subframes), PSF30(30 subframes), PSF40(40 subframes), PSF50(50 subframes), PSF60(60 subframes), PSF80(80 subframes), PSF100(100 subframes), PSF200(200 subframes)

PSF1~0, PSF2~1, PSF3~2, PSF4~3, PSF5~4, PSF6~5, PSF8~6, PSF10~7, PSF20~8, PSF30~9, subframe PSF40~10, PSF50~11, PSF60~12, PSF80~13, PSF100~14, PSF200~15

DRX

Enumeration Type

PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 subframes), PSF6(6 subframes), PSF8(8 subframes), PSF10(10 subframes), PSF20(20 subframes), PSF30(30 subframes), PSF40(40 subframes), PSF50(50 subframes), PSF60(60 subframes), PSF80(80 subframes), PSF100(100 subframes), PSF200(200 subframes), PSF300(300 subframes), PSF500(500 subframes), PSF750(750 subframes), PSF1280(1280 subframes), PSF1920(1920

PSF1~0, PSF2~1, PSF3~2, PSF4~3, PSF5~4, PSF6~5, PSF8~6, PSF10~7, PSF20~8, PSF30~9, PSF40~10, PSF50~11, PSF60~12, subframe PSF80~13, PSF100~14, PSF200~15, PSF300~16, PSF500~17, PSF750~18, PSF1280~19, PSF1920~20, PSF2560~21

DRX DL Asynchronous HARQ

Enumeration Type

sf1(1 subframe), sf2(2 subframes), sf4(4 subframes), sf6(6 subframes), sf8(8 subframes), sf16(16 subframes), sf24(24 subframes), sf33(33 subframes)

sf1~0, sf2~1, sf4~2, sf6~3, sf8~4, subframe sf16~5, sf24~6, sf33~7

DRX

Enumeration Type

SF10(10 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 subframes), SF64(64 subframes), SF80(80 subframes), SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes), SF1024(1024 subframes), SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes)

SF10~0, SF20~1, SF32~2, SF40~3, SF64~4, SF80~5, SF128~6, SF160~7, SF256~8, SF320~9, SF512~10, subframe SF640~11, SF1024~12, SF1280~13, SF2048~14, SF2560~15

DRX

Enumeration Type

UU_DISABLE(Disa ble), UU_DISABLE~0, UU_ENABLE(Enabl UU_ENABLE~1 e)

None

DRX

Enumeration Type

SF2(2 subframes), SF5(5 subframes), SF8(8 subframes), SF10(10 subframes), SF16(16 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 subframes), SF64(64 subframes), SF80(80 subframes), SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes)

SF2~0, SF5~1, SF8~2, SF10~3, SF16~4, SF20~5, SF32~6, SF40~7, SF64~8, SF80~9, SF128~10, SF160~11, SF256~12, SF320~13, SF512~14, SF640~15

subframe

DRX

Interval Type

1~16

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and Interval Type GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN

0~9

N/A

None

PS Inter-RAT Mobility between EUTRAN and GERAN SRVCC to GERAN PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000 PS Inter-RAT Mobility between EUTRAN and UTRAN SRVCC to UTRAN

0~30

N/A

0.5dB

SRVCC to GERAN SRVCC to UTRAN PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Enumeration Type Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

SRVCC to GERAN PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN

-141~-43

N/A

dBm

SRVCC to GERAN PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN

-40~-6

N/A

0.5dB

SRVCC to GERAN PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN

-141~-43

N/A

dBm

SRVCC to GERAN PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN

-40~-6

N/A

0.5dB

Mobility Management

Interval Type

0~15

N/A

dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~30

N/A

0.5dB

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

-63~0

N/A

0.5dB

PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

-63~0

N/A

0.5dB

Enhanced Scheduling Dynamic Scheduling

Interval Type

10~254

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

Coverage Based Inter-frequency Handover

Interval Type

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~9

N/A

None

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~9

N/A

None

Coverage Based Intra-frequency Handover

Interval Type

0~9

N/A

None

DRX

Interval Type

0~9

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

Enhanced Scheduling Dynamic Scheduling

Enumeration Type

QCI1(QCI 1), QCI2(QCI 2), QCI3(QCI 3), QCI4(QCI 4), QCI5(QCI 5), QCI6(QCI 6), QCI7(QCI 7), QCI8(QCI 8), QCI9(QCI 9)

QCI1~1, QCI2~2, QCI3~3, QCI4~4, QCI5~5, QCI6~6, QCI7~7, QCI8~8, QCI9~9

None

Coverage Based Inter-frequency Handover

Interval Type

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000 PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~9

N/A

None

0~9

N/A

None

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~9

N/A

None

Coverage Based Intra-frequency Handover

Interval Type

0~9

N/A

None

DRX

Interval Type

0~9

N/A

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

ms5(SRI 5ms), ms10(SRI 10ms), ms20(SRI 20ms), ms40(SRI 40ms), ms80(SRI 80ms)

ms5~0, ms10~1, ms20~2, ms40~3, ms80~4

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~9

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

0~30

N/A

0.5dB

PS Inter-RAT Mobility between EInterval Type UTRAN and CDMA2000

-63~0

N/A

0.5dB

PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

PS Inter-RAT Mobility between EUTRAN and Interval Type CDMA2000 Intra-LTE Load Balancing

-63~0

N/A

0.5dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EUTRAN and Interval Type GERAN SRVCC to GERAN

0~9

N/A

None

PS Inter-RAT Mobility between EUTRAN and GERAN Interval Type SRVCC to GERAN Service based interRAT handover to GERAN

0~30

N/A

0.5dB

PS Inter-RAT Mobility between EUTRAN and Interval Type GERAN SRVCC to GERAN

-110~-48

N/A

dBm

PS Inter-RAT Mobility between EUTRAN and GERAN Enumeration Type SRVCC to GERAN Service based interRAT handover to GERAN

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

PS Inter-RAT Mobility between EUTRAN and GERAN Intra-LTE Load Interval Type Balancing Service based interRAT handover to GERAN

-110~-48

N/A

dBm

3GPP R8 Specifications

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EUTRAN and Interval Type UTRAN SRVCC to UTRAN

0~9

N/A

None

PS Inter-RAT Mobility between EUTRAN and Interval Type UTRAN SRVCC to UTRAN

-48~0

N/A

0.5dB

PS Inter-RAT Mobility between EUTRAN and Interval Type UTRAN SRVCC to UTRAN

-120~-25

N/A

dBm

PS Inter-RAT Mobility between EUTRAN and UTRAN Interval Type SRVCC to UTRAN Service based interRAT handover to UTRAN

0~30

N/A

0.5dB

PS Inter-RAT Mobility between EUTRAN and UTRAN Enumeration Type SRVCC to UTRAN Service based interRAT handover to UTRAN

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

PS Inter-RAT Mobility between EUTRAN and UTRAN Intra-LTE Load Interval Type Balancing Service based interRAT handover to UTRAN

-48~0

N/A

0.5dB

PS Inter-RAT Mobility between EUTRAN and UTRAN Intra-LTE Load Interval Type Balancing Service based interRAT handover to UTRAN

-120~-25

N/A

dBm

3GPP R8 Specifications

Interval Type

0~17

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

0~9

N/A

None

Coverage Based Inter-frequency Handover

Interval Type

0~30

N/A

0.5dB

Coverage Based Inter-frequency Handover

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

Coverage Based Inter-frequency Handover

Interval Type

-141~-43

N/A

dBm

Coverage Based Inter-frequency Handover

Interval Type

-40~-6

N/A

0.5dB

Coverage Based Inter-frequency Handover

Interval Type

-141~-43

N/A

dBm

Coverage Based Inter-frequency Handover

Interval Type

-40~-6

N/A

0.5dB

Coverage Based Inter-frequency Handover

Interval Type

0~30

N/A

0.5dB

Coverage Based Inter-frequency Handover

Interval Type

-141~-43

N/A

dBm

Coverage Based Inter-frequency Handover

Interval Type

-40~-6

N/A

0.5dB

Coverage Based Inter-frequency Handover

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

Intra-LTE Load Balancing

Interval Type

-141~-43

N/A

dBm

Intra-LTE Load Balancing

Interval Type

-40~-6

N/A

0.5dB

None

Interval Type

-141~-43

N/A

dBm

None

Interval Type

-40~-6

N/A

0.5dB

Coverage Based Inter-frequency Handover

Interval Type

-30~30

N/A

0.5dB

Coverage Based Inter-frequency Handover

Interval Type

-141~-44

N/A

dBm

Coverage Based Inter-frequency Handover

Interval Type

-141~-44

N/A

dBm

None

Interval Type

-140~-43

N/A

dBm

None

Interval Type

-40~-6

N/A

0.5dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

0~9

N/A

None

Coverage Based Intra-frequency Handover Intra-LTE Load Balancing

Interval Type

0~30

N/A

0.5dB

Coverage Based Intra-frequency Handover

Interval Type

-30~30

N/A

0.5dB

Coverage Based Intra-frequency Handover

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

None

Character String Type

1~32 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Enumeration Type

CNOPERATOR_P RIMARY(Primary Operator), CNOPERATOR_SE CONDARY(Second ary Operator)

CNOPERATOR_P RIMARY~0, None CNOPERATOR_SE CONDARY~1

None

Character String Type

3 characters

N/A

None

None

Character String Type

2~3 characters

N/A

None

None

Interval Type

0~65535

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~65535

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~65535

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

Emergency Call

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Emergency Call

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Emergency Call

Interval Type

1~15

N/A

None

Emergency Call

Interval Type

1~15

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Enumeration Type

INDEPENDENT(Ind ependent Operator Mode), SHARED_FREQ(S hared Frequency Sharing Mode), SEPARATED_FRE Q(Separate Frequency Sharing Mode)

INDEPENDENT~0, SHARED_FREQ~1, None SEPARATED_FRE Q~2

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier License Management

Interval Type

1~100

N/A

None

Interval Type

1~300

N/A

None

Interval Type

1~300

N/A

S1-flex

Interval Type

0~15

N/A

None

S1-flex

Interval Type

0~79

N/A

None

S1-flex RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

3GPP R8 Specifications

Enumeration Type

Release_R8(Releas e 8), Release_R8~0, Release_R9(Releas Release_R9~1, e 9), Release_R10~2 Release_R10(Relea se 10)

None

None

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

None

Enumeration Type

None

Enumeration Type

Normal(Normal), Abnormal(Abnormal ) Normal(Normal), Abnormal(Abnormal ), Blocked(Blocked) FALSE(FALSE), TRUE(TRUE), NULL(NULL)

Normal~0, Abnormal~1 Normal~0, Abnormal~1, Blocked~2 FALSE~0, TRUE~1, NULL~2

None

None

S1-flex

Enumeration Type

None

None

Interval Type

0~3600

N/A

None

None

Character String Type

0~150 characters

N/A

None

S1-flex RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

0~224 characters

N/A

None

None

Character String Type

0~300 characters

N/A

None

None

Interval Type

0~255

N/A

None

None

Enumeration Type

Null(Null), LowerLinkFault(Low er Layer Link Fault), MmecImpact(Mmec Impact), SetupFail(Setup Failure), CfgErr(Configuratio n Error), LicRestrict(License Restriction), PlmnDiff(The PLMN of the operator owning the S1 interface is not supported by the MME), TacNotCfg(The TAC for the operator owning the S1 interface is not configured), Undefine(Undefine)

Null~0, LowerLinkFault~1, MmecImpact~2, SetupFail~3, CfgErr~4, LicRestrict~5, PlmnDiff~6, TacNotCfg~7, Undefine~255

None

None

Interval Type

0~15

N/A

None

None

Enumeration Type

DISABLE(disable), ENABLE(enable)

DISABLE~0, ENABLE~1

None

None

Character String Type

3 characters

N/A

None

None

Character String Type

2~3 characters

N/A

None

None

Interval Type

0~1048575

N/A

None

None

Enumeration Type

X2_BLACK_LIST_T YPE(), X2_WHITE_LIST_T YPE()

X2_BLACK_LIST_T YPE~0, None X2_WHITE_LIST_T YPE~1

Mobility Management Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

16~79

N/A

None

None

Interval Type

0~79

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~3

N/A

None

3GPP R8 Specifications

Enumeration Type

Release_R8(Releas e 8), Release_R8~0, Release_R9(Releas Release_R9~1, e 9), Release_R10~2 Release_R10(Relea se 10)

None

None

Enumeration Type

FORBID_AUTO_R MV(Forbid Auto Remove), PERMIT_AUTO_R MV(Permit Auto Remove)

FORBID_AUTO_R MV~0, None PERMIT_AUTO_R MV~1

None

Character String Type

0~50 characters

N/A

None

None

Character String Type

0~50 characters

N/A

None

None

Enumeration Type

Normal(Normal), Normal~0, Abnormal(Abnormal Abnormal~1 )

None

None

Enumeration Type

SCTP_LINK_FAUL T(SCTP Link Failure), SETUP_FAILURE_ OCCUR(Setup Failure), PEERIN_BLACK_LI ST(Peer eNodeB Blacklisted), STATE_NORMAL( NULL), SETUP_ONLY_ON E_LINK_ALLOWED (Only one interface allowed to be setup between two logical eNodeBs)

SCTP_LINK_FAUL T~0, SETUP_FAILURE_ OCCUR~1, PEERIN_BLACK_LI ST~2, None STATE_NORMAL~ 3, SETUP_ONLY_ON E_LINK_ALLOWED ~4

DRX

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

DRX

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

DRX

Enumeration Type

SF10(10 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 subframes), SF64(64 subframes), SF80(80 subframes), SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes), SF1024(1024 subframes), SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes)

SF10~0, SF20~1, SF32~2, SF40~3, SF64~4, SF80~5, SF128~6, SF160~7, SF256~8, SF320~9, SF512~10, subframe SF640~11, SF1024~12, SF1280~13, SF2048~14, SF2560~15

DRX

Enumeration Type

PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 subframes), PSF6(6 subframes), PSF8(8 subframes), PSF10(10 subframes), PSF20(20 subframes), PSF30(30 subframes), PSF40(40 subframes), PSF50(50 subframes), PSF60(60 subframes), PSF80(80 subframes), PSF100(100 subframes), PSF200(200 subframes)

PSF1~0, PSF2~1, PSF3~2, PSF4~3, PSF5~4, PSF6~5, PSF8~6, PSF10~7, PSF20~8, PSF30~9, subframe PSF40~10, PSF50~11, PSF60~12, PSF80~13, PSF100~14, PSF200~15

DRX

Enumeration Type

PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 subframes), PSF6(6 subframes), PSF8(8 subframes), PSF10(10 subframes), PSF20(20 subframes), PSF30(30 subframes), PSF40(40 subframes), PSF50(50 subframes), PSF60(60 subframes), PSF80(80 subframes), PSF100(100 subframes), PSF200(200 subframes), PSF300(300 subframes), PSF500(500 subframes), PSF750(750 subframes), PSF1280(1280 subframes), PSF1920(1920

PSF1~0, PSF2~1, PSF3~2, PSF4~3, PSF5~4, PSF6~5, PSF8~6, PSF10~7, PSF20~8, PSF30~9, PSF40~10, PSF50~11, PSF60~12, subframe PSF80~13, PSF100~14, PSF200~15, PSF300~16, PSF500~17, PSF750~18, PSF1280~19, PSF1920~20, PSF2560~21

DRX

Enumeration Type

UU_DISABLE(Disa ble), UU_DISABLE~0, UU_ENABLE(Enabl UU_ENABLE~1 e)

None

DRX

Enumeration Type

SF2(2 subframes), SF5(5 subframes), SF8(8 subframes), SF10(10 subframes), SF16(16 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 subframes), SF64(64 subframes), SF80(80 subframes), SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes)

SF2~0, SF5~1, SF8~2, SF10~3, SF16~4, SF20~5, SF32~6, SF40~7, SF64~8, SF80~9, SF128~10, SF160~11, SF256~12, SF320~13, SF512~14, SF640~15

subframe

DRX

Interval Type

1~16

N/A

None

DRX

Enumeration Type

SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes), SF1024(1024 subframes), SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes) SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes), SF1024(1024 subframes), SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes)

SF128~6, SF160~7, SF256~8, SF320~9, SF512~10, SF640~11, subframe SF1024~12, SF1280~13, SF2048~14, SF2560~15

DRX

Enumeration Type

SF128~6, SF160~7, SF256~8, SF320~9, SF512~10, SF640~11, subframe SF1024~12, SF1280~13, SF2048~14, SF2560~15

Enhanced Scheduling Dynamic Scheduling

Interval Type

10~254

N/A

None

Enhanced Scheduling Dynamic Scheduling

Enumeration Type

IMSSignalling(IMS Signalling), LowDelay(Low Delay), TCPorBuffStreamin g(TCP Based or Buffered Streaming)

IMSSignalling~5, LowDelay~7, None TCPorBuffStreamin g~9

Enhanced Scheduling Dynamic Scheduling

Interval Type

1~1000

N/A

0.001

Enhanced Scheduling Dynamic Scheduling

Interval Type

1~1000

N/A

0.001

Basic Scheduling Enhanced Scheduling

Enumeration Type

MinGbrRate_0_KB( 0KB/s), MinGbrRate_1_KB( 1KB/s), MinGbrRate_2_KB( 2KB/s), MinGbrRate_4KB(4 KB/s), MinGbrRate_8_KB( 8KB/s), MinGbrRate_16_KB (16KB/s), MinGbrRate_32_KB (32KB/s), MinGbrRate_64_KB (64KB/s), MinGbrRate_128_K B(128KB/s), MinGbrRate_256_K B(256KB/s), MinGbrRate_512_K B(512KB/s)

MinGbrRate_0_KB~ 0, MinGbrRate_1_KB~ 8000, MinGbrRate_2_KB~ 16000, MinGbrRate_4KB~3 2000, MinGbrRate_8_KB~ 64000, MinGbrRate_16_KB KB/s ~128000, MinGbrRate_32_KB ~256000, MinGbrRate_64_KB ~512000, MinGbrRate_128_K B~1024000, MinGbrRate_256_K B~2048000, MinGbrRate_512_K B~4096000

Basic Scheduling Enhanced Scheduling

Enumeration Type

MinGbrRate_0_KB( 0KB/s), MinGbrRate_1_KB( 1KB/s), MinGbrRate_2_KB( 2KB/s), MinGbrRate_4KB(4 KB/s), MinGbrRate_8_KB( 8KB/s), MinGbrRate_16_KB (16KB/s), MinGbrRate_32_KB (32KB/s), MinGbrRate_64_KB (64KB/s), MinGbrRate_128_K B(128KB/s), MinGbrRate_256_K B(256KB/s), MinGbrRate_512_K B(512KB/s)

MinGbrRate_0_KB~ 0, MinGbrRate_1_KB~ 8000, MinGbrRate_2_KB~ 16000, MinGbrRate_4KB~3 2000, MinGbrRate_8_KB~ 64000, MinGbrRate_16_KB KB/s ~128000, MinGbrRate_32_KB ~256000, MinGbrRate_64_KB ~512000, MinGbrRate_128_K B~1024000, MinGbrRate_256_K B~2048000, MinGbrRate_512_K B~4096000

Basic Scheduling Enhanced Scheduling

Interval Type

0~10

N/A

0.1

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN Service based interInterval Type RAT handover to UTRAN Inter-RAT Load Sharing to GERAN Inter-RAT Load Sharing to UTRAN Service based interRAT handover to GERAN CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT

0~39

N/A

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

PBR_0_KBps(0KB/ s), PBR_8_KBps(8KB/ s), PBR_16_KBps(16K B/s), PBR_32_KBps(32K B/s), PBR_64_KBps(64K B/s), PBR_128_KBps(12 8KB/s), PBR_256_KBps(25 6KB/s), PBR_INFINITY(Infin ity)

PBR_0_KBps~0, PBR_8_KBps~1, PBR_16_KBps~2, PBR_32_KBps~3, KB/s PBR_64_KBps~4, PBR_128_KBps~5, PBR_256_KBps~6, PBR_INFINITY~7

Basic Scheduling Enhanced Scheduling

Interval Type

9~16

N/A

None

Radio Bearer Management

Interval Type

0~39

N/A

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

PAID_USER(Paid User), PAID_USER~0, FREE_USER(Free FREE_USER~1 User)

None

Transport Overbooking Transport Differentiated Flow Control Transport Resource Overload Control Enumeration Type Transport Dynamic Flow Control Different Transport Paths based on QoS Grade Intra-LTE Load Balancing

FLOW_CTRL(Flow FLOW_CTRL~0, Control), NON_FLOW_CTRL None NON_FLOW_CTRL ~1 (Non Flow Control)

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN Intra-LTE Load Balancing Interval Type Service based interRAT handover to UTRAN Inter-RAT Load Sharing to GERAN Inter-RAT Load Sharing to UTRAN Service based interRAT handover to GERAN CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT

0~39

N/A

None

SRVCC to UTRAN PS Inter-RAT Mobility between E- Bit Field Type UTRAN and UTRAN

PS_HO, SRVCC, REDIRECTION

PS_HO~0, SRVCC~1, REDIRECTION~2

None

SRVCC to GERAN Bit Field Type

SRVCC

SRVCC~0

None

PS Inter-RAT Mobility between EBit Field Type UTRAN and GERAN

PS_HO~0, PS_HO, NACC_HO~1, NACC_HO, CCO_HO~2, CCO_HO, SRVCC, SRVCC~3, REDIRECTION REDIRECTION~4

None

PS Inter-RAT Mobility between EBit Field Type UTRAN and CDMA2000

SRVCC(CDMA1XR SRVCC~0 TTHoSwitch)

None

PS Inter-RAT Mobility between EBit Field Type UTRAN and CDMA2000

OPT_HO, NON_OPT_HO

OPT_HO~0, NON_OPT_HO~1

None

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN Intra-LTE Load Balancing Enumeration Type Service based interRAT handover to UTRAN Inter-RAT Load Sharing to GERAN Inter-RAT Load Sharing to UTRAN Service based interRAT handover to GERAN CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT

PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

PERMIT_FAST_AN PERMIT_FAST_AN R_MEAS_ENUM~0 R_MEAS_ENUM, , None FORBID_FAST_AN FORBID_FAST_AN R_MEAS_ENUM R_MEAS_ENUM~1

None

Interval Type

0~15

N/A

None

None

Interval Type

0~15

N/A

None

None

Interval Type

0~15

N/A

None

Radio Bearer Management

Interval Type

0~39

N/A

None

Radio Bearer Management

Enumeration Type

DiscardTimer_50(5 0 ms), DiscardTimer_100( 100 ms), DiscardTimer_150( 150 ms), DiscardTimer_300( 300 ms), DiscardTimer_500( 500 ms), DiscardTimer_750( 750 ms), DiscardTimer_1500 (1500 ms), DiscardTimer_Infinit y(infinity)

DiscardTimer_50~0 , DiscardTimer_100~ 1, DiscardTimer_150~ 2, DiscardTimer_300~ 3, ms DiscardTimer_500~ 4, DiscardTimer_750~ 5, DiscardTimer_1500 ~6, DiscardTimer_Infinit y~7

Radio Bearer Management

Enumeration Type

RlcMode_AM(Ackn owledge Mode), RlcMode_AM~1, RlcMode_UM(Un- RlcMode_UM~2 acknowledge Mode)

None

Radio Bearer Management

Enumeration Type

Maxretx_Threshold _t1(1), Maxretx_Threshold _t2(2), Maxretx_Threshold _t3(3), Maxretx_Threshold _t4(4), Maxretx_Threshold _t6(6), Maxretx_Threshold _t8(8), Maxretx_Threshold _t16(16), Maxretx_Threshold _t32(32)

Maxretx_Threshold _t1~0, Maxretx_Threshold _t2~1, Maxretx_Threshold _t3~2, Maxretx_Threshold _t4~3, None Maxretx_Threshold _t6~4, Maxretx_Threshold _t8~5, Maxretx_Threshold _t16~6, Maxretx_Threshold _t32~7

Radio Bearer Management

Enumeration Type

Maxretx_Threshold _t1(1), Maxretx_Threshold _t2(2), Maxretx_Threshold _t3(3), Maxretx_Threshold _t4(4), Maxretx_Threshold _t6(6), Maxretx_Threshold _t8(8), Maxretx_Threshold _t16(16), Maxretx_Threshold _t32(32)

Maxretx_Threshold _t1~0, Maxretx_Threshold _t2~1, Maxretx_Threshold _t3~2, Maxretx_Threshold _t4~3, None Maxretx_Threshold _t6~4, Maxretx_Threshold _t8~5, Maxretx_Threshold _t16~6, Maxretx_Threshold _t32~7

Radio Bearer Management

Enumeration Type

PollByte_kb25(25 kBytes), PollByte_kb50(50 kBytes), PollByte_kb75(75 kBytes), PollByte_kb100(100 kBytes), PollByte_kb125(125 kBytes), PollByte_kb250(250 kBytes), PollByte_kb375(375 kBytes), PollByte_kb500(500 kBytes), PollByte_kb750(750 kBytes), PollByte_kb1000(10 00 kBytes), PollByte_kb1250(12 50 kBytes), PollByte_kb1500(15 00 kBytes), PollByte_kb2000(20 00 kBytes), PollByte_kb3000(30 00 kBytes), PollByte_infinity(infi nite kBytes)

PollByte_kb25~0, PollByte_kb50~1, PollByte_kb75~2, PollByte_kb100~3, PollByte_kb125~4, PollByte_kb250~5, PollByte_kb375~6, PollByte_kb500~7, PollByte_kb750~8, PollByte_kb1000~9, byte PollByte_kb1250~1 0, PollByte_kb1500~1 1, PollByte_kb2000~1 2, PollByte_kb3000~1 3, PollByte_infinity~14

Radio Bearer Management

Enumeration Type

PollByte_kb25(25 kBytes), PollByte_kb50(50 kBytes), PollByte_kb75(75 kBytes), PollByte_kb100(100 kBytes), PollByte_kb125(125 kBytes), PollByte_kb250(250 kBytes), PollByte_kb375(375 kBytes), PollByte_kb500(500 kBytes), PollByte_kb750(750 kBytes), PollByte_kb1000(10 00 kBytes), PollByte_kb1250(12 50 kBytes), PollByte_kb1500(15 00 kBytes), PollByte_kb2000(20 00 kBytes), PollByte_kb3000(30 00 kBytes), PollByte_infinity(infi nite kBytes)

PollByte_kb25~0, PollByte_kb50~1, PollByte_kb75~2, PollByte_kb100~3, PollByte_kb125~4, PollByte_kb250~5, PollByte_kb375~6, PollByte_kb500~7, PollByte_kb750~8, PollByte_kb1000~9, byte PollByte_kb1250~1 0, PollByte_kb1500~1 1, PollByte_kb2000~1 2, PollByte_kb3000~1 3, PollByte_infinity~14

Radio Bearer Management

Enumeration Type

PollPdu_p4(4 PDUs), PollPdu_p8(8 PDUs), PollPdu_p16(16 PDUs), PollPdu_p32(32 PDUs), PollPdu_p64(64 PDUs), PollPdu_p128(128 PDUs), PollPdu_p256(256 PDUs), PollPdu_Infinity(infi nite PDUs)

PollPdu_p4~0, PollPdu_p8~1, PollPdu_p16~2, PollPdu_p32~3, PollPdu_p64~4, PollPdu_p128~5, PollPdu_p256~6, PollPdu_Infinity~7

None

Radio Bearer Management

Enumeration Type

PollPdu_p4(4 PDUs), PollPdu_p8(8 PDUs), PollPdu_p16(16 PDUs), PollPdu_p32(32 PDUs), PollPdu_p64(64 PDUs), PollPdu_p128(128 PDUs), PollPdu_p256(256 PDUs), PollPdu_Infinity(infi nite PDUs)

PollPdu_p4~0, PollPdu_p8~1, PollPdu_p16~2, PollPdu_p32~3, PollPdu_p64~4, PollPdu_p128~5, PollPdu_p256~6, PollPdu_Infinity~7

None

Radio Bearer Management

Enumeration Type

Tpollretrans_m5(5m s), Tpollretrans_m10(1 0ms), Tpollretrans_m15(1 5ms), Tpollretrans_m20(2 0ms), Tpollretrans_m25(2 5ms), Tpollretrans_m30(3 0ms), Tpollretrans_m35(3 5ms), Tpollretrans_m40(4 0ms), Tpollretrans_m45(4 5ms), Tpollretrans_m50(5 0ms), Tpollretrans_m55(5 5ms), Tpollretrans_m60(6 0ms), Tpollretrans_m65(6 5ms), Tpollretrans_m70(7 0ms), Tpollretrans_m75(7 5ms), Tpollretrans_m80(8 0ms), Tpollretrans_m85(8 5ms),

Tpollretrans_m5~0, Tpollretrans_m10~1 , Tpollretrans_m15~2 , Tpollretrans_m20~3 , Tpollretrans_m25~4 , Tpollretrans_m30~5 , Tpollretrans_m35~6 , Tpollretrans_m40~7 , Tpollretrans_m45~8 , ms Tpollretrans_m50~9 , Tpollretrans_m55~1 0, Tpollretrans_m60~1 1, Tpollretrans_m65~1 2, Tpollretrans_m70~1 3, Tpollretrans_m75~1 4, Tpollretrans_m80~1 5, Tpollretrans_m85~1 6, Tpollretrans_m90~1

Radio Bearer Management

Enumeration Type

Tpollretrans_m5(5m s), Tpollretrans_m10(1 0ms), Tpollretrans_m15(1 5ms), Tpollretrans_m20(2 0ms), Tpollretrans_m25(2 5ms), Tpollretrans_m30(3 0ms), Tpollretrans_m35(3 5ms), Tpollretrans_m40(4 0ms), Tpollretrans_m45(4 5ms), Tpollretrans_m50(5 0ms), Tpollretrans_m55(5 5ms), Tpollretrans_m60(6 0ms), Tpollretrans_m65(6 5ms), Tpollretrans_m70(7 0ms), Tpollretrans_m75(7 5ms), Tpollretrans_m80(8 0ms), Tpollretrans_m85(8 5ms),

Tpollretrans_m5~0, Tpollretrans_m10~1 , Tpollretrans_m15~2 , Tpollretrans_m20~3 , Tpollretrans_m25~4 , Tpollretrans_m30~5 , Tpollretrans_m35~6 , Tpollretrans_m40~7 , Tpollretrans_m45~8 , ms Tpollretrans_m50~9 , Tpollretrans_m55~1 0, Tpollretrans_m60~1 1, Tpollretrans_m65~1 2, Tpollretrans_m70~1 3, Tpollretrans_m75~1 4, Tpollretrans_m80~1 5, Tpollretrans_m85~1 6, Tpollretrans_m90~1

Radio Bearer Management

Enumeration Type

Tstatprohibit_m0(0 ms), Tstatprohibit_m5(5 ms), Tstatprohibit_m10(1 0ms), Tstatprohibit_m15(1 5ms), Tstatprohibit_m20(2 0ms), Tstatprohibit_m25(2 5ms), Tstatprohibit_m30(3 0ms), Tstatprohibit_m35(3 5ms), Tstatprohibit_m40(4 0ms), Tstatprohibit_m45(4 5ms), Tstatprohibit_m50(5 0ms), Tstatprohibit_m55(5 5ms), Tstatprohibit_m60(6 0ms), Tstatprohibit_m65(6 5ms), Tstatprohibit_m70(7 0ms), Tstatprohibit_m75(7 5ms), Tstatprohibit_m80(8 0ms),

Tstatprohibit_m0~0, Tstatprohibit_m5~1, Tstatprohibit_m10~ 2, Tstatprohibit_m15~ 3, Tstatprohibit_m20~ 4, Tstatprohibit_m25~ 5, Tstatprohibit_m30~ 6, Tstatprohibit_m35~ 7, Tstatprohibit_m40~ 8, Tstatprohibit_m45~ ms 9, Tstatprohibit_m50~ 10, Tstatprohibit_m55~ 11, Tstatprohibit_m60~ 12, Tstatprohibit_m65~ 13, Tstatprohibit_m70~ 14, Tstatprohibit_m75~ 15, Tstatprohibit_m80~ 16, Tstatprohibit_m85~ 17,

Radio Bearer Management

Enumeration Type

Tstatprohibit_m0(0 ms), Tstatprohibit_m5(5 ms), Tstatprohibit_m10(1 0ms), Tstatprohibit_m15(1 5ms), Tstatprohibit_m20(2 0ms), Tstatprohibit_m25(2 5ms), Tstatprohibit_m30(3 0ms), Tstatprohibit_m35(3 5ms), Tstatprohibit_m40(4 0ms), Tstatprohibit_m45(4 5ms), Tstatprohibit_m50(5 0ms), Tstatprohibit_m55(5 5ms), Tstatprohibit_m60(6 0ms), Tstatprohibit_m65(6 5ms), Tstatprohibit_m70(7 0ms), Tstatprohibit_m75(7 5ms), Tstatprohibit_m80(8 0ms),

Tstatprohibit_m0~0, Tstatprohibit_m5~1, Tstatprohibit_m10~ 2, Tstatprohibit_m15~ 3, Tstatprohibit_m20~ 4, Tstatprohibit_m25~ 5, Tstatprohibit_m30~ 6, Tstatprohibit_m35~ 7, Tstatprohibit_m40~ 8, Tstatprohibit_m45~ ms 9, Tstatprohibit_m50~ 10, Tstatprohibit_m55~ 11, Tstatprohibit_m60~ 12, Tstatprohibit_m65~ 13, Tstatprohibit_m70~ 14, Tstatprohibit_m75~ 15, Tstatprohibit_m80~ 16, Tstatprohibit_m85~ 17,

Radio Bearer Management

Enumeration Type

Treordering_m0(0m s), Treordering_m5(5m s), Treordering_m10(1 0ms), Treordering_m15(1 5ms), Treordering_m20(2 0ms), Treordering_m25(2 5ms), Treordering_m30(3 0ms), Treordering_m35(3 5ms), Treordering_m40(4 0ms), Treordering_m45(4 5ms), Treordering_m50(5 0ms), Treordering_m55(5 5ms), Treordering_m60(6 0ms), Treordering_m65(6 5ms), Treordering_m70(7 0ms), Treordering_m75(7 5ms), Treordering_m80(8 0ms),

Treordering_m0~0, Treordering_m5~1, Treordering_m10~2 , Treordering_m15~3 , Treordering_m20~4 , Treordering_m25~5 , Treordering_m30~6 , Treordering_m35~7 , Treordering_m40~8 , Treordering_m45~9 ms , Treordering_m50~1 0, Treordering_m55~1 1, Treordering_m60~1 2, Treordering_m65~1 3, Treordering_m70~1 4, Treordering_m75~1 5, Treordering_m80~1 6, Treordering_m85~1 7,

Radio Bearer Management

Enumeration Type

Treordering_m0(0m s), Treordering_m5(5m s), Treordering_m10(1 0ms), Treordering_m15(1 5ms), Treordering_m20(2 0ms), Treordering_m25(2 5ms), Treordering_m30(3 0ms), Treordering_m35(3 5ms), Treordering_m40(4 0ms), Treordering_m45(4 5ms), Treordering_m50(5 0ms), Treordering_m55(5 5ms), Treordering_m60(6 0ms), Treordering_m65(6 5ms), Treordering_m70(7 0ms), Treordering_m75(7 5ms), Treordering_m80(8 0ms),

Treordering_m0~0, Treordering_m5~1, Treordering_m10~2 , Treordering_m15~3 , Treordering_m20~4 , Treordering_m25~5 , Treordering_m30~6 , Treordering_m35~7 , Treordering_m40~8 , Treordering_m45~9 ms , Treordering_m50~1 0, Treordering_m55~1 1, Treordering_m60~1 2, Treordering_m65~1 3, Treordering_m70~1 4, Treordering_m75~1 5, Treordering_m80~1 6, Treordering_m85~1 7,

Radio Bearer Management

Enumeration Type

PdcpSnsize_7bits(7 bits), PdcpSnsize_12bits( 12 bits)

PdcpSnsize_7bits~ 0, bit PdcpSnsize_12bits ~1

Radio Bearer Management

Enumeration Type

RlcSnSize_size5(5b RlcSnSize_size5~0, its), RlcSnSize_size10~ bit RlcSnSize_size10(1 1 0bits)

Radio Bearer Management

Enumeration Type

RlcSnSize_size5(5b RlcSnSize_size5~0, its), RlcSnSize_size10~ bit RlcSnSize_size10(1 1 0bits)

Radio Bearer Management

Enumeration Type

Treordering_m0(0m s), Treordering_m5(5m s), Treordering_m10(1 0ms), Treordering_m15(1 5ms), Treordering_m20(2 0ms), Treordering_m25(2 5ms), Treordering_m30(3 0ms), Treordering_m35(3 5ms), Treordering_m40(4 0ms), Treordering_m45(4 5ms), Treordering_m50(5 0ms), Treordering_m55(5 5ms), Treordering_m60(6 0ms), Treordering_m65(6 5ms), Treordering_m70(7 0ms), Treordering_m75(7 5ms), Treordering_m80(8 0ms),

Treordering_m0~0, Treordering_m5~1, Treordering_m10~2 , Treordering_m15~3 , Treordering_m20~4 , Treordering_m25~5 , Treordering_m30~6 , Treordering_m35~7 , Treordering_m40~8 , Treordering_m45~9 ms , Treordering_m50~1 0, Treordering_m55~1 1, Treordering_m60~1 2, Treordering_m65~1 3, Treordering_m70~1 4, Treordering_m75~1 5, Treordering_m80~1 6, Treordering_m85~1 7,

Radio Bearer Management

Enumeration Type

Treordering_m0(0m s), Treordering_m5(5m s), Treordering_m10(1 0ms), Treordering_m15(1 5ms), Treordering_m20(2 0ms), Treordering_m25(2 5ms), Treordering_m30(3 0ms), Treordering_m35(3 5ms), Treordering_m40(4 0ms), Treordering_m45(4 5ms), Treordering_m50(5 0ms), Treordering_m55(5 5ms), Treordering_m60(6 0ms), Treordering_m65(6 5ms), Treordering_m70(7 0ms), Treordering_m75(7 5ms), Treordering_m80(8 0ms),

Treordering_m0~0, Treordering_m5~1, Treordering_m10~2 , Treordering_m15~3 , Treordering_m20~4 , Treordering_m25~5 , Treordering_m30~6 , Treordering_m35~7 , Treordering_m40~8 , Treordering_m45~9 ms , Treordering_m50~1 0, Treordering_m55~1 1, Treordering_m60~1 2, Treordering_m65~1 3, Treordering_m70~1 4, Treordering_m75~1 5, Treordering_m80~1 6, Treordering_m85~1 7,

Radio Bearer Management

Enumeration Type

FALSE(FALSE), TRUE(TRUE)

FALSE~0, TRUE~1 None

Enhanced Scheduling Dynamic Scheduling

Enumeration Type

QCI1(QCI 1), QCI2(QCI 2), QCI3(QCI 3), QCI4(QCI 4), QCI5(QCI 5), QCI6(QCI 6), QCI7(QCI 7), QCI8(QCI 8), QCI9(QCI 9)

QCI1~1, QCI2~2, QCI3~3, QCI4~4, QCI5~5, QCI6~6, QCI7~7, QCI8~8, QCI9~9

None

Enhanced Scheduling Dynamic Scheduling

Interval Type

1~1000

N/A

0.001

Enhanced Scheduling Dynamic Scheduling

Interval Type

1~1000

N/A

0.001

Basic Scheduling Enhanced Scheduling

Enumeration Type

MinGbrRate_0_KB( 0KB/s), MinGbrRate_1_KB( 1KB/s), MinGbrRate_2_KB( 2KB/s), MinGbrRate_4KB(4 KB/s), MinGbrRate_8_KB( 8KB/s), MinGbrRate_16_KB (16KB/s), MinGbrRate_32_KB (32KB/s), MinGbrRate_64_KB (64KB/s), MinGbrRate_128_K B(128KB/s), MinGbrRate_256_K B(256KB/s), MinGbrRate_512_K B(512KB/s)

MinGbrRate_0_KB~ 0, MinGbrRate_1_KB~ 8000, MinGbrRate_2_KB~ 16000, MinGbrRate_4KB~3 2000, MinGbrRate_8_KB~ 64000, MinGbrRate_16_KB KB/s ~128000, MinGbrRate_32_KB ~256000, MinGbrRate_64_KB ~512000, MinGbrRate_128_K B~1024000, MinGbrRate_256_K B~2048000, MinGbrRate_512_K B~4096000

Basic Scheduling Enhanced Scheduling

Enumeration Type

MinGbrRate_0_KB( 0KB/s), MinGbrRate_1_KB( 1KB/s), MinGbrRate_2_KB( 2KB/s), MinGbrRate_4KB(4 KB/s), MinGbrRate_8_KB( 8KB/s), MinGbrRate_16_KB (16KB/s), MinGbrRate_32_KB (32KB/s), MinGbrRate_64_KB (64KB/s), MinGbrRate_128_K B(128KB/s), MinGbrRate_256_K B(256KB/s), MinGbrRate_512_K B(512KB/s)

MinGbrRate_0_KB~ 0, MinGbrRate_1_KB~ 8000, MinGbrRate_2_KB~ 16000, MinGbrRate_4KB~3 2000, MinGbrRate_8_KB~ 64000, MinGbrRate_16_KB KB/s ~128000, MinGbrRate_32_KB ~256000, MinGbrRate_64_KB ~512000, MinGbrRate_128_K B~1024000, MinGbrRate_256_K B~2048000, MinGbrRate_512_K B~4096000

Basic Scheduling Enhanced Scheduling

Interval Type

0~10

N/A

0.1

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN Service based interInterval Type RAT handover to UTRAN Inter-RAT Load Sharing to GERAN Inter-RAT Load Sharing to UTRAN Service based interRAT handover to GERAN CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT Basic Scheduling Enhanced Scheduling

0~39

N/A

None

Interval Type

0~39

N/A

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

PBR_0_KBps(0KB/ s), PBR_8_KBps(8KB/ s), PBR_16_KBps(16K B/s), PBR_32_KBps(32K B/s), PBR_64_KBps(64K B/s), PBR_128_KBps(12 8KB/s), PBR_256_KBps(25 6KB/s), PBR_INFINITY(Infin ity)

PBR_0_KBps~0, PBR_8_KBps~1, PBR_16_KBps~2, PBR_32_KBps~3, KB/s PBR_64_KBps~4, PBR_128_KBps~5, PBR_256_KBps~6, PBR_INFINITY~7

Basic Scheduling Enhanced Scheduling

Interval Type

9~16

N/A

None

Transport Overbooking Transport Differentiated Flow Control Transport Resource Overload Control Enumeration Type Transport Dynamic Flow Control Different Transport Paths based on QoS Grade Intra-LTE Load Balancing

FLOW_CTRL(Flow FLOW_CTRL~0, Control), NON_FLOW_CTRL None NON_FLOW_CTRL ~1 (Non Flow Control)

Dynamic Scheduling

Enumeration Type

CLASS_0(CLASS_ 0), CLASS_0~0, CLASS_1(CLASS_ CLASS_1~1, 1), CLASS_2~2 CLASS_2(CLASS_ 2)

None

DRX DL 2x2 MIMO DL 4x2 MIMO BEAMFORMING AND MIMO ADAPTIVE SWITCH (Test Feature)

Enumeration Type

NO_ADAPTIVE(NO _ADAPTIVE), TxD_BF_ADAPTIV E(TxD_BF_ADAPTI VE), MIMO_BF_ADAPTI VE(MIMO_BF_ADA PTIVE)

NO_ADAPTIVE~0, TxD_BF_ADAPTIV E~1, None MIMO_BF_ADAPTI VE~2

DRX DL 2x2 MIMO DL 4x2 MIMO BEAMFORMING AND MIMO ADAPTIVE SWITCH (Test Feature)

Enumeration Type

TM2(TM2), TM3(TM3), TM7(TM7), TM8(TM8), TM4(TM4)

TM2~0, TM3~1, TM7~2, TM8~3, TM4~4

None

Basic Scheduling

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Basic Scheduling

Enumeration Type

ms2(2ms), ms5(5ms), ms10(10ms), ms20(20ms), ms32(32ms), ms40(40ms), ms64(64ms), ms80(80ms), ms128(128ms), ms160(160ms)

ms2~2, ms5~5, ms10~10, ms20~20, ms32~32, ms40~40, ms64~64, ms80~80, ms128~128, ms160~160

ms

DL 2x2 MIMO DL 4x2 MIMO

Enumeration Type

NO_ADAPTIVE(NO _ADAPTIVE), OL_ADAPTIVE(OL _ADAPTIVE), CL_ADAPTIVE(CL_ ADAPTIVE), OC_ADAPTIVE(OC _ADAPTIVE)

NO_ADAPTIVE~0, OL_ADAPTIVE~1, None CL_ADAPTIVE~2, OC_ADAPTIVE~3

DL 2x2 MIMO DL 4x2 MIMO

Enumeration Type

TM2(TM2), TM3(TM3), TM4(TM4), TM6(TM6)

TM2~0, TM3~1, TM4~2, TM6~3

None

Basic Scheduling

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Basic Scheduling

Enumeration Type

ms5(5ms), ms10(10ms), ms20(20ms), ms40(40ms)

ms5~1, ms10~2, ms20~3, ms40~4

ms

None

Enumeration Type

QCI1(QCI 1), QCI2(QCI 2), QCI3(QCI 3), QCI4(QCI 4), QCI5(QCI 5), QCI6(QCI 6), QCI7(QCI 7), QCI8(QCI 8), QCI9(QCI 9)

QCI1~1, QCI2~2, QCI3~3, QCI4~4, QCI5~5, QCI6~6, QCI7~7, QCI8~8, QCI9~9

None

None

Enumeration Type

None

Enumeration Type

TPeriodBSRTimer_ sf5(5 subframes), TPeriodBSRTimer_ sf10(10 subframes), TPeriodBSRTimer_ sf16(16 subframes), TPeriodBSRTimer_ sf20(20 subframes), TPeriodBSRTimer_ sf32(32 subframes), TPeriodBSRTimer_ sf40(40 subframes), TPeriodBSRTimer_ sf64(64 subframes), TPeriodBSRTimer_ sf80(80 subframes), TPeriodBSRTimer_ sf128(128 subframes), TPeriodBSRTimer_ sf160(160 subframes), TPeriodBSRTimer_ sf320(320 subframes), TPeriodBSRTimer_ sf640(640 subframes), TPeriodBSRTimer_ sf1280(1280 subframes), TPeriodBSRTimer_ sf2560(2560 subframes), sf320(sf320), sf640(sf640), sf1280(sf1280), sf2560(sf2560), sf5120(sf5120), sf10240(sf10240)

TPeriodBSRTimer_ sf5~0, TPeriodBSRTimer_ sf10~1, TPeriodBSRTimer_ sf16~2, TPeriodBSRTimer_ sf20~3, TPeriodBSRTimer_ sf32~4, TPeriodBSRTimer_ sf40~5, TPeriodBSRTimer_ sf64~6, TPeriodBSRTimer_ subframe sf80~7, TPeriodBSRTimer_ sf128~8, TPeriodBSRTimer_ sf160~9, TPeriodBSRTimer_ sf320~10, TPeriodBSRTimer_ sf640~11, TPeriodBSRTimer_ sf1280~12, TPeriodBSRTimer_ sf2560~13, TPeriodBSRTimer_i nfinity~14

sf320~0, sf640~1, sf1280~2, sf2560~3, sf5120~4, sf10240~5

subframe

Coverage Based Inter-frequency Handover PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between E- Enumeration Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN

GAP_PATTERN_T YPE_1, GAP_PATTERN_T YPE_2

GAP_PATTERN_T YPE_1~1, None GAP_PATTERN_T YPE_2~2

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Enumeration Type

FC0~0, FC1~1, FC2~2, FC3~3, FC0, FC1, FC2, FC4~4, FC5~5, FC3, FC4, FC5, FC6~6, FC7~7, FC6, FC7, FC8, FC8~8, FC9~9, None FC9, FC11, FC13, FC11~10, FC15, FC17, FC19 FC13~11, FC15~12, FC17~13, FC19~14

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Enumeration Type

FC0~0, FC1~1, FC2~2, FC3~3, FC0, FC1, FC2, FC4~4, FC5~5, FC3, FC4, FC5, FC6~6, FC7~7, FC6, FC7, FC8, FC8~8, FC9~9, None FC9, FC11, FC13, FC11~10, FC15, FC17, FC19 FC13~11, FC15~12, FC17~13, FC19~14

PS Inter-RAT Mobility between EUTRAN and GERAN Enumeration Type SRVCC to GERAN CS Fallback to GERAN

FC0~0, FC1~1, FC2~2, FC3~3, FC0, FC1, FC2, FC4~4, FC5~5, FC3, FC4, FC5, FC6~6, FC7~7, FC6, FC7, FC8, FC8~8, FC9~9, None FC9, FC11, FC13, FC11~10, FC15, FC17, FC19 FC13~11, FC15~12, FC17~13, FC19~14

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover SRVCC to GERAN PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN

NOT_CFG, CFG

NOT_CFG~0, CFG~1

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover PS Inter-RAT Mobility between EUTRAN and UTRAN Interval Type PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN

-141~-43

N/A

dBm

High Speed Mobility Ultra High Speed Enumeration Type Mobility

NOT_CFG, CFG

NOT_CFG~0, CFG~1

None

High Speed Mobility Ultra High Speed Enumeration Type Mobility

T_CRMAX_30S(30 s), T_CRMAX_60S(60 s), T_CRMAX_120S(1 20s), T_CRMAX_180S(1 80s), T_CRMAX_240S(2 40s)

T_CRMAX_30S~0, T_CRMAX_60S~1, T_CRMAX_120S~2 , s T_CRMAX_180S~3 , T_CRMAX_240S~4

High Speed Mobility Ultra High Speed Enumeration Type Mobility

T_CRMAXHYST_3 0S(30s), T_CRMAXHYST_6 0S(60s), T_CRMAXHYST_1 20S(120s), T_CRMAXHYST_1 80S(180s), T_CRMAXHYST_2 40S(240s)

T_CRMAXHYST_3 0S~0, T_CRMAXHYST_6 0S~1, T_CRMAXHYST_1 s 20S~2, T_CRMAXHYST_1 80S~3, T_CRMAXHYST_2 40S~4

High Speed Mobility Interval Type

1~16

N/A

None

High Speed Mobility Ultra High Speed Interval Type Mobility

1~16

N/A

None

High Speed Mobility Enumeration Type

TTT_SF_MEDIUM_ 0DOT25(0.25), TTT_SF_MEDIUM_ 0DOT50(0.5), TTT_SF_MEDIUM_ 0DOT75(0.75), TTT_SF_MEDIUM_ LDOT0(1)

TTT_SF_MEDIUM_ 0DOT25~0, TTT_SF_MEDIUM_ 0DOT50~1, None TTT_SF_MEDIUM_ 0DOT75~2, TTT_SF_MEDIUM_ LDOT0~3

High Speed Mobility Ultra High Speed Enumeration Type Mobility

TTT_SF_HIGH_0D OT25(0.25), TTT_SF_HIGH_0D OT50(0.5), TTT_SF_HIGH_0D OT75(0.75), TTT_SF_HIGH_LD OT0(1)

TTT_SF_HIGH_0D OT25~0, TTT_SF_HIGH_0D OT50~1, None TTT_SF_HIGH_0D OT75~2, TTT_SF_HIGH_LD OT0~3

PS Inter-RAT Mobility between EUTRAN and UTRAN Enumeration Type SRVCC to UTRAN CS Fallback to UTRAN

FC0~0, FC1~1, FC2~2, FC3~3, FC0, FC1, FC2, FC4~4, FC5~5, FC3, FC4, FC5, FC6~6, FC7~7, FC6, FC7, FC8, FC8~8, FC9~9, None FC9, FC11, FC13, FC11~10, FC15, FC17, FC19 FC13~11, FC15~12, FC17~13, FC19~14

PS Inter-RAT Mobility between EUTRAN and UTRAN Enumeration Type SRVCC to UTRAN CS Fallback to UTRAN

FC0~0, FC1~1, FC2~2, FC3~3, FC0, FC1, FC2, FC4~4, FC5~5, FC3, FC4, FC5, FC6~6, FC7~7, FC6, FC7, FC8, FC8~8, FC9~9, None FC9, FC11, FC13, FC11~10, FC15, FC17, FC19 FC13~11, FC15~12, FC17~13, FC19~14

PS Inter-RAT Handover between LTE and GERAN / PS Inter-RAT Mobility between EUTRAN and GERAN SRVCC to GERAN PS Inter-RAT Handover between LTE and Interval Type CDMA2000 PS Inter-RAT Handover between LTE and UMTS / PS Inter-RAT Mobility between EUTRAN and UTRAN SRVCC to UMTS / SRVCC to UTRAN

1~8

N/A

None

PS Inter-RAT Mobility between EUTRAN and GERAN SRVCC to GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 PS Inter-RAT Enumeration Type Mobility between EUTRAN and UTRAN SRVCC to UTRAN Service based interRAT handover to UTRAN Service based interRAT handover to GERAN

r1(1), r2(2), r4(4), r8(8), r16(16), r32(32), r64(64), Infinity(Infinity)

r1~0, r2~1, r4~2, r8~3, r16~4, r32~5, None r64~6, Infinity~7

PS Inter-RAT Mobility between EUTRAN and GERAN Enumeration Type SRVCC to GERAN Service based interRAT handover to GERAN

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

PS Inter-RAT Handover between LTE and UMTS / PS Inter-RAT Mobility between E- Enumeration Type UTRAN and UTRAN SRVCC to UMTS / SRVCC to UTRAN

UTRAN_RSCP, UTRAN_ECN0, UTRAN_BOTH

UTRAN_RSCP~0, UTRAN_ECN0~1, UTRAN_BOTH~2

None

PS Inter-RAT Mobility between EUTRAN and UTRAN Enumeration Type SRVCC to UTRAN Service based interRAT handover to UTRAN

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000

PILOT_STRENGTH PILOT_STRENGTH ~0, , PILOT_PN_PHASE None PILOT_PN_PHASE _AND_STRENGTH _AND_STRENGTH ~1

PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000

PILOT_STRENGTH

PILOT_STRENGTH None ~0

PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

PS Inter-RAT Mobility between EUTRAN and GERAN SRVCC to GERAN PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000 PS Inter-RAT Mobility between EUTRAN and UTRAN SRVCC to UTRAN

RSRP, RSRQ, BOTH

RSRP~0, RSRQ~1, None BOTH~2

PS Inter-RAT Mobility between EUTRAN and GERAN SRVCC to GERAN PS Inter-RAT Mobility between EEnumeration Type UTRAN and CDMA2000 PS Inter-RAT Mobility between EUTRAN and UTRAN SRVCC to UTRAN

EventB1(EventB1), EventB1~0, EventB2(EventB2) EventB2~1

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

1~8

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover Intra-LTE Load Balancing

Enumeration Type

r1(1), r2(2), r4(4), r8(8), r16(16), r32(32), r64(64), Infinity(Infinity)

r1~0, r2~1, r4~2, r8~3, r16~4, r32~5, None r64~6, Infinity~7

Coverage Based Intra-frequency Handover

Enumeration Type

RSRP, RSRQ

RSRP~0, RSRQ~1 None

Coverage Based Intra-frequency Handover

Enumeration Type

SAME_AS_TRIG_ QUAN(Same as Trig Quan), BOTH

SAME_AS_TRIG_ None QUAN~0, BOTH~1

Coverage Based Intra-frequency Handover Intra-LTE Load Balancing

Enumeration Type

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

Coverage Based Inter-frequency Handover Intra-LTE Load Balancing

Enumeration Type

SAME_AS_TRIG_ QUAN(Same as Trig Quan), BOTH

SAME_AS_TRIG_ None QUAN~0, BOTH~1

Coverage Based Inter-frequency Handover Intra-LTE Load Balancing

Enumeration Type

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

Coverage Based Inter-frequency Handover

Enumeration Type

RSRP, RSRQ, BOTH

RSRP~0, RSRQ~1, None BOTH~2

Coverage Based Inter-frequency Handover

Enumeration Type

RSRP, RSRQ, BOTH

RSRP~0, RSRQ~1, None BOTH~2

Coverage Based Inter-frequency Handover

Enumeration Type

RSRP, RSRQ, BOTH

RSRP~0, RSRQ~1, None BOTH~2

3GPP R8 Specifications

Interval Type

0~17

N/A

None

CS Fallback to UTRAN

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

CS Fall Back to GERAN

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

CS Fallback to Enumeration Type CDMA2000 1xRTT

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

CS Fallback to UTRAN

Interval Type

-120~-25

N/A

dBm

CS Fallback to UTRAN

Interval Type

-48~0

N/A

0.5dB

CS Fall Back to GERAN

Interval Type

-110~-48

N/A

dBm

CS Fallback to Interval Type CDMA2000 1xRTT

-63~0

N/A

0.5dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Emergency Call

Enumeration Type

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

P00(0%), P05(5%), P10(10%), P15(15%), P20(20%), P25(25%), P30(30%), P40(40%), P50(50%), P60(60%), P70(70%), P75(75%), P80(80%), P85(85%), P90(90%), P95(95%)

P00~0, P05~1, P10~2, P15~3, P20~4, P25~5, P30~6, P40~7, P50~8, P60~9, P70~10, P75~11, P80~12, P85~13, P90~14, P95~15

3GPP R8 Specifications Enumeration Type Broadcast of system information

ACCESS_BARRIN G_TIME_S4(4s), ACCESS_BARRIN G_TIME_S8(8s), ACCESS_BARRIN G_TIME_S16(16s), ACCESS_BARRIN G_TIME_S32(32s), ACCESS_BARRIN G_TIME_S64(64s), ACCESS_BARRIN G_TIME_S128(128 s), ACCESS_BARRIN G_TIME_S256(256 s), ACCESS_BARRIN G_TIME_S512(512 s)

ACCESS_BARRIN G_TIME_S4~0, ACCESS_BARRIN G_TIME_S8~1, ACCESS_BARRIN G_TIME_S16~2, ACCESS_BARRIN G_TIME_S32~3, s ACCESS_BARRIN G_TIME_S64~4, ACCESS_BARRIN G_TIME_S128~5, ACCESS_BARRIN G_TIME_S256~6, ACCESS_BARRIN G_TIME_S512~7

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

P00(0%), P05(5%), P10(10%), P15(15%), P20(20%), P25(25%), P30(30%), P40(40%), P50(50%), P60(60%), P70(70%), P75(75%), P80(80%), P85(85%), P90(90%), P95(95%)

P00~0, P05~1, P10~2, P15~3, P20~4, P25~5, P30~6, P40~7, P50~8, P60~9, P70~10, P75~11, P80~12, P85~13, P90~14, P95~15

3GPP R8 Specifications Enumeration Type Broadcast of system information

ACCESS_BARRIN G_TIME_S4(4s), ACCESS_BARRIN G_TIME_S8(8s), ACCESS_BARRIN G_TIME_S16(16s), ACCESS_BARRIN G_TIME_S32(32s), ACCESS_BARRIN G_TIME_S64(64s), ACCESS_BARRIN G_TIME_S128(128 s), ACCESS_BARRIN G_TIME_S256(256 s), ACCESS_BARRIN G_TIME_S512(512 s)

ACCESS_BARRIN G_TIME_S4~0, ACCESS_BARRIN G_TIME_S8~1, ACCESS_BARRIN G_TIME_S16~2, ACCESS_BARRIN G_TIME_S32~3, s ACCESS_BARRIN G_TIME_S64~4, ACCESS_BARRIN G_TIME_S128~5, ACCESS_BARRIN G_TIME_S256~6, ACCESS_BARRIN G_TIME_S512~7

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

CELL_BARRED(Ba CELL_BARRED~0, rred), CELL_NOT_BARR None CELL_NOT_BARR ED~1 ED(Not Barred)

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

CELL_RESERVED( Reserved), CELL_NOT_RESE RVED(Not Reserved)

CELL_RESERVED ~0, None CELL_NOT_RESE RVED~1

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

ALLOWED, NOT_ALLOWED

ALLOWED~0, None NOT_ALLOWED~1

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NORMAL_MODE(N ormal mode), NORMAL_MODE~0 None RR_MODE(Round , RR_MODE~1 Robin Mode)

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

1~720

N/A

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~65535

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

CELL_RESERVED _FOR_OP(Reserve d), CELL_NOT_RESE RVED_FOR_OP(N ot Reserved)

CELL_RESERVED _FOR_OP~0, None CELL_NOT_RESE RVED_FOR_OP~1

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

1~100

N/A

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

1~100

N/A

None

Interval Type

0~3

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

DB0_Q_HYST(0dB) , DB1_Q_HYST(1dB) , DB2_Q_HYST(2dB) , DB3_Q_HYST(3dB) , DB4_Q_HYST(4dB) , DB5_Q_HYST(5dB) , DB6_Q_HYST(6dB) , DB8_Q_HYST(8dB) , DB10_Q_HYST(10 dB), DB12_Q_HYST(12 dB), DB14_Q_HYST(14 dB), DB16_Q_HYST(16 dB), DB18_Q_HYST(18 dB), DB20_Q_HYST(20 dB), DB22_Q_HYST(22 dB), DB24_Q_HYST(24 dB)

DB0_Q_HYST~0, DB1_Q_HYST~1, DB2_Q_HYST~2, DB3_Q_HYST~3, DB4_Q_HYST~4, DB5_Q_HYST~5, DB6_Q_HYST~6, DB8_Q_HYST~7, DB10_Q_HYST~8, DB12_Q_HYST~9, DB14_Q_HYST~10 dB , DB16_Q_HYST~11 , DB18_Q_HYST~12 , DB20_Q_HYST~13 , DB22_Q_HYST~14 , DB24_Q_HYST~15

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

S30_T_EVALULATI ON(30s), S60_T_EVALULATI ON(60s), S120_T_EVALULA TION(120s), S180_T_EVALULA TION(180s), S240_T_EVALULA TION(240s)

S30_T_EVALULATI ON~0, S60_T_EVALULATI ON~1, S120_T_EVALULA s TION~2, S180_T_EVALULA TION~3, S240_T_EVALULA TION~4

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

S30_T_HYST_NOR MAL(30s), S60_T_HYST_NOR MAL(60s), S120_T_HYST_NO RMAL(120s), S180_T_HYST_NO RMAL(180s), S240_T_HYST_NO RMAL(240s)

S30_T_HYST_NOR MAL~0, S60_T_HYST_NOR MAL~1, S120_T_HYST_NO s RMAL~2, S180_T_HYST_NO RMAL~3, S240_T_HYST_NO RMAL~4

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

1~16

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

1~16

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

DB_6_Q_HYST_SF _MEDIUM(-6dB), DB_4_Q_HYST_SF _MEDIUM(-4dB), DB_2_Q_HYST_SF _MEDIUM(-2dB), DB0_Q_HYST_SF_ MEDIUM(0dB)

DB_6_Q_HYST_SF _MEDIUM~0, DB_4_Q_HYST_SF _MEDIUM~1, dB DB_2_Q_HYST_SF _MEDIUM~2, DB0_Q_HYST_SF_ MEDIUM~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

DB_6_Q_HYST_SF _HIGH(-6dB), DB_4_Q_HYST_SF _HIGH(-4dB), DB_2_Q_HYST_SF _HIGH(-2dB), DB0_Q_HYST_SF_ HIGH(0dB)

DB_6_Q_HYST_SF _HIGH~0, DB_4_Q_HYST_SF _HIGH~1, dB DB_2_Q_HYST_SF _HIGH~2, DB0_Q_HYST_SF_ HIGH~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~31

N/A

2dB

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~31

N/A

2dB

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Reselection

0~7

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

-70~-22

N/A

2dBm

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

-30~33

N/A

dBm

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~31

N/A

2dB

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

MBW6(1.4M), MBW15(3M), MBW25(5M), MBW50(10M), MBW75(15M), MBW100(20M)

MBW6~0, MBW15~1, MBW25~2, MBW50~3, MBW75~4, MBW100~5

MHz

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~7

N/A

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

BitString00(00), BitString01(01), BitString10(10), BitString11(11)

BitString00~0, BitString01~1, BitString10~2, BitString11~3

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Broadcast of system information Interval Type Cell Selection and Re-selection

0~31

N/A

dB

Broadcast of system information Interval Type Cell Selection and Re-selection

0~31

N/A

dB

Broadcast of system information Enumeration Type Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Broadcast of system information Interval Type Cell Selection and Re-selection

0~31

N/A

dB

Broadcast of system information Enumeration Type Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Broadcast of system information Interval Type Cell Selection and Re-selection

-34~-3

N/A

dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~15

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~255

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~255

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~255

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~7

N/A

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Reselection CS Fallback to CDMA2000 1xRTT

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

0~32767

N/A

None

3GPP R8 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

0~65535

N/A

None

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

0~127

N/A

None

3GPP R8 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

0~4095

N/A

None

3GPP R8 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

0~7

N/A

None

3GPP R8 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fallback to CDMA2000 1xRTT

0~7

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Character String system information Type Cell Selection and Re-selection

0~6 characters

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~7

N/A

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R9 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R9 Specifications Broadcast of Enumeration Type system information Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~63

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R9 Specifications Broadcast of system information Interval Type Cell Selection and Re-selection CS Fall Back to 1x RTT

0~7

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~7

N/A

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection Mobility Management

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection Mobility Management

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection Mobility Management

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~7

N/A

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection Mobility Management

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection Mobility Management

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications Broadcast of system information Enumeration Type Cell Selection and Re-selection Mobility Management

T_RESEL_SF_0DO T25(0.25), T_RESEL_SF_0DO T5(0.5), T_RESEL_SF_0DO T75(0.75), T_RESEL_SF_1DO T0(1.0)

T_RESEL_SF_0DO T25~0, T_RESEL_SF_0DO T5~1, None T_RESEL_SF_0DO T75~2, T_RESEL_SF_1DO T0~3

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

-70~-22

N/A

2dBm

3GPP R8 Specifications Broadcast of Interval Type system information Cell Selection and Re-selection

0~8

N/A

2dB

Broadcast of system information Interval Type Cell Selection and Re-selection

-34~-3

N/A

dB

Broadcast of system information Enumeration Type Cell Selection and Re-selection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Broadcast of system information Interval Type Cell Selection and Re-selection

1~8

N/A

dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Enumeration Type Broadcast of system information

RF8(8 radio frames), RF16(16 radio frames), RF32(32 radio frames), RF64(64 radio frames), RF128(128 radio frames), RF256(256 radio frames), RF512(512 radio frames)

RF8~0, RF16~1, RF32~2, RF64~3, None RF128~4, RF256~5, RF512~6

3GPP R8 Specifications Interval Type Broadcast of system information

1~300

N/A

3GPP R8 Specifications Enumeration Type Broadcast of system information

MERGE, DISCARD

MERGE~0, DISCARD~1

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

MERGE, DISCARD

MERGE~0, DISCARD~1

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

AL0(0), AL04(0.4), AL05(0.5), AL06(0.6), AL07(0.7), AL08(0.8), AL09(0.9), AL1(1)

AL0~0, AL04~1, AL05~2, AL06~3, AL07~4, AL08~5, AL09~6, AL1~7

None

3GPP R8 Specifications Broadcast of Interval Type system information Uplink Power Control

-127~-96

N/A

dBm

3GPP R8 Specifications Broadcast of Interval Type system information Uplink Power Control

-126~24

N/A

dBm

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

DELTAF_2(-2dB), DELTAF0(0dB), DELTAF2(2dB)

DELTAF_2~0, DELTAF0~1, DELTAF2~2

dB

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

DELTAF1(1dB), DELTAF3(3dB), DELTAF5(5dB)

DELTAF1~0, DELTAF3~1, DELTAF5~2

dB

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

DELTAF_2(-2dB), DELTAF0(0dB), DELTAF1(1dB), DELTAF2(2dB)

DELTAF_2~0, DELTAF0~1, DELTAF1~2, DELTAF2~3

dB

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

DELTAF_2(-2dB), DELTAF0(0dB), DELTAF2(2dB)

DELTAF_2~0, DELTAF0~1, DELTAF2~2

dB

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

DELTAF_2(-2dB), DELTAF0(0dB), DELTAF2(2dB)

DELTAF_2~0, DELTAF0~1, DELTAF2~2

dB

3GPP R8 Specifications Broadcast of Interval Type system information Uplink Power Control

-1~6

N/A

2dB

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

SF500(), SF750(), SF1280(), SF1920(), SF2560(), SF5120(), SF10240(), INFINITY()

SF500~0, SF750~1, SF1280~2, SF1920~3, SF2560~4, None SF5120~5, SF10240~6, INFINITY~7

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

MS100_T300(100m s), MS200_T300(200m s), MS300_T300(300m s), MS400_T300(400m s), MS600_T300(600m s), MS1000_T300(100 0ms), MS1500_T300(150 0ms), MS2000_T300(200 0ms)

MS100_T300~0, MS200_T300~1, MS300_T300~2, MS400_T300~3, MS600_T300~4, MS1000_T300~5, MS1500_T300~6, MS2000_T300~7

ms

3GPP R8 Specifications Enumeration Type Broadcast of system information

MS100_T301(100m s), MS200_T301(200m s), MS300_T301(300m s), MS400_T301(400m s), MS600_T301(600m s), MS1000_T301(100 0ms), MS1500_T301(150 0ms), MS2000_T301(200 0ms)

MS100_T301~0, MS200_T301~1, MS300_T301~2, MS400_T301~3, MS600_T301~4, MS1000_T301~5, MS1500_T301~6, MS2000_T301~7

ms

3GPP R8 Specifications Enumeration Type Broadcast of system information

MS0_T310(0ms), MS50_T310(50ms), MS100_T310(100m s), MS200_T310(200m s), MS500_T310(500m s), MS1000_T310(100 0ms), MS2000_T310(200 0ms)

MS0_T310~0, MS50_T310~1, MS100_T310~2, MS200_T310~3, MS500_T310~4, MS1000_T310~5, MS2000_T310~6

ms

3GPP R8 Specifications Enumeration Type Broadcast of system information

MS1000_T311(100 0ms), MS3000_T311(300 0ms), MS5000_T311(500 0ms), MS10000_T311(10 000ms), MS15000_T311(15 000ms), MS20000_T311(20 000ms), MS30000_T311(30 000ms)

MS1000_T311~0, MS3000_T311~1, MS5000_T311~2, MS10000_T311~3, ms MS15000_T311~4, MS20000_T311~5, MS30000_T311~6

3GPP R8 Specifications Enumeration Type Broadcast of system information 3GPP R8 Specifications Enumeration Type Broadcast of system information

n1(1), n2(2), n3(3), n4(4), n5(5), n6(6), n8(8), n10(10)

n1~0, n2~1, n3~2, n4~3, n5~4, n6~5, n8~6, n10~7

None

n1(1), n2(2), n3(3), n4(4), n6(6), n8(8), n10(10), n20(20)

n1~0, n2~1, n3~2, n4~3, n6~4, n8~5, n10~6, n20~7

None

None

Interval Type

0~17

N/A

None

None

Character String Type

1~99 characters

N/A

None

None

Interval Type

0~17

N/A

None

Broadcast of Enumeration Type system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Broadcast of system information CP length Enumeration Type Normal CP Extended CP

NORMAL_CP(Norm al), NORMAL_CP~0, None EXTENDED_CP(Ex EXTENDED_CP~1 tended)

CP length Normal CP Extended CP

Enumeration Type

NORMAL_CP(Norm al), NORMAL_CP~0, None EXTENDED_CP(Ex EXTENDED_CP~1 tended)

Broadcast of system information 3GPP R9 Interval Type Specifications 3GPP R10 Specifications

1~43,61~64

N/A

None

Broadcast of Enumeration Type system information

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Broadcast of system information 3GPP R9 Interval Type Specifications 3GPP R10 Specifications

18000~45589,6443 N/A 6~65535

None

Broadcast of system information 3GPP R9 Interval Type Specifications 3GPP R10 Specifications

0~45589,64436~65 N/A 535

None

Scalable Bandwidth Broadcast of Enumeration Type system information

CELL_BW_N6(1.4 M), CELL_BW_N15(3M ), CELL_BW_N25(5M ), CELL_BW_N50(10 M), CELL_BW_N75(15 M), CELL_BW_N100(2 0M)

CELL_BW_N6~0, CELL_BW_N15~1, CELL_BW_N25~2, None CELL_BW_N50~3, CELL_BW_N75~4, CELL_BW_N100~5

Scalable Bandwidth Broadcast of Enumeration Type system information

CELL_BW_N6(1.4 M), CELL_BW_N15(3M ), CELL_BW_N25(5M ), CELL_BW_N50(10 M), CELL_BW_N75(15 M), CELL_BW_N100(2 0M)

CELL_BW_N6~0, CELL_BW_N15~1, CELL_BW_N25~2, None CELL_BW_N50~3, CELL_BW_N75~4, CELL_BW_N100~5

Broadcast of Interval Type system information

0~255

N/A

None

Broadcast of Interval Type system information

0~503

N/A

None

Broadcast of Interval Type system information

1~32

N/A

None

None

Enumeration Type

CELL_DEACTIVE( Deactivated), CELL_DEACTIVE~ None CELL_ACTIVE(Acti 0, CELL_ACTIVE~1 ve) CELL_UNBLOCK(U nblock), CELL_HIGH_BLOC K(High block), CELL_MIDDLE_BL OCK(Middle block), CELL_LOW_BLOC K(Low block) CELL_UNBLOCK~ 0, CELL_HIGH_BLOC K~1, None CELL_MIDDLE_BL OCK~2, CELL_LOW_BLOC K~3

None

Enumeration Type

None

Interval Type

1~1440

N/A

min

Broadcast of Enumeration Type system information

CELL_FDD(FDD), CELL_TDD(TDD)

CELL_FDD~0, CELL_TDD~1

None

Broadcast of system information uplink-downlink subframe configuration Enumeration Type type1&2 uplink-downlink subframe configuration type 0/5

SA0(SA0), SA1(SA1), SA2(SA2), SA3(SA3), SA4(SA4), SA5(SA5), SA6(SA6)

SA0~0, SA1~1, SA2~2, SA3~3, SA4~4, SA5~5, SA6~6

None

Broadcast of system information uplink-downlink special subframe configuration type 7 uplink-downlink Enumeration Type special subframe configuration type 4 uplink-downlink special subframe configuration type 5

SSP0(SSP0), SSP1(SSP1), SSP2(SSP2), SSP3(SSP3), SSP4(SSP4), SSP5(SSP5), SSP6(SSP6), SSP7(SSP7), SSP8(SSP8)

SSP0~0, SSP1~1, SSP2~2, SSP3~3, SSP4~4, SSP5~5, SSP6~6, SSP7~7, SSP8~8

None

None

Enumeration Type

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

None

Enumeration Type

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Random Access Procedure

Interval Type

0~837

N/A

None

High Speed Mobility Ultra High Speed Enumeration Type Mobility

LOW_SPEED(Low speed cell flag), HIGH_SPEED(High speed cell flag), ULTRA_HIGH_SPE ED(Ultra high speed cell flag), EXTRA_HIGH_SPE ED(Extra high speed cell flag)

LOW_SPEED~0, HIGH_SPEED~1, ULTRA_HIGH_SPE None ED~2, EXTRA_HIGH_SPE ED~3

Random Access Procedure

Interval Type

0~4

N/A

None

Random Access Procedure

Interval Type

1~100000

N/A

Compact Bandwidth Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Compact Bandwidth Interval Type

48~50,96~100,146~ N/A 150,183~200

0.1MHz

Compact Bandwidth Interval Type

48~50,96~100,146~ N/A 150,183~200

0.1MHz

Broadcast of Enumeration Type system information

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Broadcast of Interval Type system information

0~16777215

N/A

None

3GPP R8 Specifications Broadcast of Enumeration Type system information Uplink Power Control

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Broadcast of Interval Type system information Uplink Power Control

-30~36

N/A

dBm

SFN

Enumeration Type

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True) SFN(SFN), CELL_COMBINATI ON(Cell Combination), TWO_RRU_COMBI NATION(TWO RRU Combination), DIGITAL_COMBIN ATION(Cell Digital Combination) NO_COMPRESSIO N(No Compression), NORMAL_COMPR ESSION(Normal Compression)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

SFN

Enumeration Type

SFN~0, CELL_COMBINATI ON~1, TWO_RRU_COMBI None NATION~2, DIGITAL_COMBIN ATION~3

None

Enumeration Type

NO_COMPRESSIO N~0, None NORMAL_COMPR ESSION~1

None

Enumeration Type

CELL_INST_UNIN STALL(Uninstall), CELL_INST_UEM_ CFGING(Inner software module configuring), CELL_INST_RRU_ CFGING(RRU configuring), CELL_INST_BBI_C FGING(BBI configuring), CELL_INST_RECF GING(Recfging), CELL_INST_DELE TING(Deleting), CELL_INST_NORM AL(Normal), CELL_INST_BARR ED(Barred), CELL_INST_ALLO CATING_RES(Alloc ating resource), CELL_INST_CRM_ CFGING(RRU configuring)

CELL_INST_UNIN STALL~0, CELL_INST_UEM_ CFGING~1, CELL_INST_RRU_ CFGING~2, CELL_INST_BBI_C FGING~3, CELL_INST_RECF GING~4, None CELL_INST_DELE TING~5, CELL_INST_NORM AL~6, CELL_INST_BARR ED~7, CELL_INST_ALLO CATING_RES~8, CELL_INST_CRM_ CFGING~9

None

Enumeration Type

NO_INFORMATIO N(No Information), CCEM_FAILURE(C onfiguration activation fail), CCEM_CELLALG_ ERR_CODE_NON_ BF_VERSION_CEL LACT_FAILED(Bea mforming switch prohibited for nonbeamforming cells in active mode), CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_BF_SW_ ON(The version of the Bbi with the cell does not support the BF algo), CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_MUBF_S W(The version of the Bbi with the cell does not support the MUBF algo), CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_VMIMO_ SW(The version of the Bbi with the cell does not support the UL VMIMO 0~32 characters

NO_INFORMATIO N~0, CCEM_FAILURE~1 , CCEM_CELLALG_ ERR_CODE_NON_ BF_VERSION_CEL LACT_FAILED~196 5424659, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_BF_SW_ ON~1965424662, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_MUBF_S W~1965424663, None CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_VMIMO_ SW~1965424664, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_INTRA_S UB_FRAM~196542 4665, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_EXTERN D_CP~1965424666 , CCEM_CH_PUSC H_HOPING_OFFS ET_INVALID_CFG~ N/A None

None

Character String Type

None

Enumeration Type

CELL_NO_OP(No Operation), CELL_SETUP_ACT (Act Cell), CELL_SETUP_UBL (UnBlock Cell), CELL_SETUP_HE ALCHK(Cell Healthy Check), CELL_SETUP_141( 141 Cell Setup), CELL_SETUP_UL WIDESCAN(UL Wide Freq Scan Cell Setup), CELL_DEL_BLK_L OW(Block Cell Low), CELL_DEL_BLK_M ID(Block Cell Mid), CELL_DEL_BLK_H IGH(Block Cell High), CELL_DEL_NOUS ER(Block Cell No User), CELL_DEL_DEA(D ea Cell), CELL_DEL_RMV(D elete Cell), CELl_DEL_HEALC HK(Cell Healthy Chk), CELL_DEL_UNHE 0~32 characters

CELL_NO_OP~0, CELL_SETUP_ACT ~1, CELL_SETUP_UBL ~2, CELL_SETUP_HE ALCHK~3, CELL_SETUP_141 ~4, CELL_SETUP_UL WIDESCAN~5, CELL_DEL_BLK_L OW~26, CELL_DEL_BLK_M ID~27, CELL_DEL_BLK_H IGH~28, None CELL_DEL_NOUS ER~29, CELL_DEL_DEA~3 0, CELL_DEL_RMV~3 1, CELl_DEL_HEALC HK~32, CELL_DEL_UNHE AL~33, CELL_DEL_SETUP _FAIL~34, CELL_DEL_141_D EL~35, CELL_DEL_ULWID ESCAN~36, CELL_DEL_CELLN N/A None

None

Character String Type

None

Enumeration Type

CELL_NO_OP(No Operation), CELL_SETUP_ACT (Act Cell), CELL_SETUP_UBL (UnBlock Cell), CELL_SETUP_HE ALCHK(Cell Healthy Check), CELL_SETUP_141( 141 Cell Setup), CELL_SETUP_UL WIDESCAN(UL Wide Freq Scan Cell Setup), CELL_DEL_BLK_L OW(Block Cell Low), CELL_DEL_BLK_M ID(Block Cell Mid), CELL_DEL_BLK_H IGH(Block Cell High), CELL_DEL_NOUS ER(Block Cell No User), CELL_DEL_DEA(D ea Cell), CELL_DEL_RMV(D elete Cell), CELl_DEL_HEALC HK(Cell Healthy Chk), CELL_DEL_UNHE

CELL_NO_OP~0, CELL_SETUP_ACT ~1, CELL_SETUP_UBL ~2, CELL_SETUP_HE ALCHK~3, CELL_SETUP_141 ~4, CELL_SETUP_UL WIDESCAN~5, CELL_DEL_BLK_L OW~26, CELL_DEL_BLK_M ID~27, CELL_DEL_BLK_H IGH~28, None CELL_DEL_NOUS ER~29, CELL_DEL_DEA~3 0, CELL_DEL_RMV~3 1, CELl_DEL_HEALC HK~32, CELL_DEL_UNHE AL~33, CELL_DEL_SETUP _FAIL~34, CELL_DEL_141_D EL~35, CELL_DEL_ULWID ESCAN~36, CELL_DEL_CELLN

None

Enumeration Type

CELL_PWRSAVE_ UNINSTALL(Uninst all), CELL_PWRSAVE_ RFSHD(RF Intelligent Shutdown Mode), CELL_PWRSAVE_ CELLSHD(Cell Intelligent Shutdown Mode), CELL_PWRSAVE_ LOWPWR_CELLU SEDPWRRDU(Low Power Consumption Mode-Cell Used Power Reduced), CELL_PWRSAVE_ LOWPWR_RSPW RRDU(Low Power Consumption ModeReference Signal Power Reduced), CELL_PWRSAVE_ LOWPWR_RFSHD (Low Power Consumption ModeRF Shutdown), CELL_PWRSAVE_ LOWPWR_CELLS HD(Low Power Consumption ModeCell Shutdown), AUTO_PWROFF_ BBI_SLOT_0(0), BBI_SLOT_1(1), BBI_SLOT_2(2), BBI_SLOT_3(3), BBI_SLOT_4(4), BBI_SLOT_5(5), BBI_SLOT_INVALI D(Invalid Slot Number)

CELL_PWRSAVE_ UNINSTALL~0, CELL_PWRSAVE_ RFSHD~1, CELL_PWRSAVE_ CELLSHD~2, CELL_PWRSAVE_ LOWPWR_CELLU SEDPWRRDU~3, CELL_PWRSAVE_ LOWPWR_RSPW RRDU~4, None CELL_PWRSAVE_ LOWPWR_RFSHD ~5, CELL_PWRSAVE_ LOWPWR_CELLS HD~6, AUTO_PWROFF_ ONTIME~7, CELL_PWRSAVE_I NTERRAT_CELLS HD~8

None

Enumeration Type

BBI_SLOT_0~0, BBI_SLOT_1~1, BBI_SLOT_2~2, BBI_SLOT_3~3, None BBI_SLOT_4~4, BBI_SLOT_5~5, BBI_SLOT_INVALI D~65535

None

Enumeration Type

BASIC_TYPE(Basic Type), TWO_RRU_COMBI NATION_TYPE(TW O RRU Combination Type), SFN_TYPE(SFN Type), BF_TYPE(BF Type), MIMO_HELP_TYP E(Mutual-Aid MIMO Type), CELL_COMBINATI ON_TYPE(Cell Combination Type), DIGITAL_COMBIN ATION_TYPE(Cell Digital Combination Type), INVALID_TYPE(Inv alid Type)

BASIC_TYPE~0, TWO_RRU_COMBI NATION_TYPE~2, SFN_TYPE~3, BF_TYPE~4, MIMO_HELP_TYP E~6, None CELL_COMBINATI ON_TYPE~14, DIGITAL_COMBIN ATION_TYPE~15, INVALID_TYPE~25 5

None

Interval Type

0~62

N/A

None

None

Interval Type

4~254

N/A

None

None

Interval Type

0~8

N/A

None

None

Enumeration Type

UNINSTALL(Uninst all), UNINSTALL~0, SYMBOL_SHUTDO SYMBOL_SHUTDO None WN(Symbol WN~1 shutdown)

None

Interval Type

0~65535

N/A

0.1dBm

None

Interval Type

0~17

N/A

None

Single Streaming Beamforming BEAMFORMING AND MIMO ADAPTIVE SWITCH (Test Feature)

Enumeration Type

SINGLE_LAYER_B SINGLE_LAYER_B F~0, F(), None DUAL_LAYER_BF~ DUAL_LAYER_BF() 1

None

Interval Type

0~17

N/A

None

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

ms

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Interval Type

1~8

N/A

None

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

r1(1), r2(2), r4(4), r8(8), r16(16), r32(32), r64(64), Infinity(Infinity)

r1~0, r2~1, r4~2, r8~3, r16~4, r32~5, None r64~6, Infinity~7

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

SAME_AS_TRIG_ QUAN(Same as Trig Quan), BOTH

SAME_AS_TRIG_ None QUAN~0, BOTH~1

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

RSRP, RSRQ

RSRP~0, RSRQ~1 None

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Interval Type

0~30

N/A

0.5dB

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

None

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Interval Type

-30~30

N/A

0.5dB

Low Power Interval Type Consumption Mode

0~17

N/A

None

Low Power Enumeration Type Consumption Mode

OFF(Off), ON(On)

OFF~0, ON~1

None

Low Power Enumeration Type Consumption Mode

OFF(Off), ON(On)

OFF~0, ON~1

None

Low Power Compound Type Consumption Mode

00:00:00~23:59:59

N/A

None

Low Power Compound Type Consumption Mode

00:00:00~23:59:59

N/A

None

Low Power Interval Type Consumption Mode

0~1440

N/A

min

Low Power Interval Type Consumption Mode

0~1440

N/A

min

Low Power Interval Type Consumption Mode

0~1440

N/A

min

Low Power Interval Type Consumption Mode

10~100

N/A

Low Power Interval Type Consumption Mode

-10~0

N/A

dB

Low Power Interval Type Consumption Mode

1~1440

N/A

min

None

Interval Type

0~17

N/A

None

Mobility Robust Enumeration Type Optimization(MRO)

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Mobility Robust Enumeration Type Optimization(MRO)

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Mobility Robust Enumeration Type Optimization(MRO)

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Interval Type Admission Control Congestion Control

1~15

N/A

None

3GPP R8 Specifications Interval Type Admission Control Congestion Control

1~15

N/A

None

3GPP R8 Specifications Admission Control

Interval Type

10~99

N/A

3GPP R8 Specifications Admission Control

Interval Type

10~99

N/A

3GPP R8 Specifications Admission Control

Interval Type

10~99

N/A

3GPP R8 Specifications Admission Control

Interval Type

10~99

N/A

3GPP R8 Specifications Admission Control

Interval Type

0~90

N/A

3GPP R8 Specifications Admission Control

Interval Type

0~90

N/A

3GPP R8 Specifications Admission Control

Interval Type

0~90

N/A

3GPP R8 Specifications Interval Type Congestion Control

0~99

N/A

3GPP R8 Specifications Interval Type Congestion Control

0~99

N/A

3GPP R8 Specifications Interval Type Congestion Control

0~99

N/A

3GPP R8 Specifications Interval Type Congestion Control

0~99

N/A

3GPP R8 Specifications Interval Type Congestion Control

1~100

N/A

3GPP R8 Specifications Interval Type Congestion Control

1~100

N/A

3GPP R8 Specifications Interval Type Congestion Control

1~100

N/A

3GPP R8 Specifications Admission Control

Interval Type

0~100

N/A

3GPP R8 Specifications Admission Control

Interval Type

0~100

N/A

3GPP R8 Specifications Interval Type Congestion Control

1~15

N/A

None

3GPP R8 Specifications Interval Type Congestion Control

0~50

N/A

3GPP R8 Specifications Radio/transport Resource Preemption

Interval Type

1~15

N/A

None

3GPP R8 Specifications Interval Type Admission Control Congestion Control

10~100

N/A

3GPP R8 Specifications Interval Type Admission Control Congestion Control

10~100

N/A

3GPP R8 Specifications Interval Type Admission Control Congestion Control

10~100

N/A

3GPP R8 Specifications Interval Type Admission Control Congestion Control

10~100

N/A

3GPP R8 Specifications Admission Control

Interval Type

0~9000

N/A

None

RF Channel Interval Type Intelligent Shutdown

0~17

N/A

None

RF Channel Enumeration Type Intelligent Shutdown

OFF(Off), ON(On)

OFF~0, ON~1

None

RF Channel Compound Type Intelligent Shutdown

00:00:00~23:59:59

N/A

None

RF Channel Compound Type Intelligent Shutdown

00:00:00~23:59:59

N/A

None

RF Channel Interval Type Intelligent Shutdown

0~7

N/A

dB

None

Interval Type

0~17

N/A

None

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Interval Type

0~2

N/A

None

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Intelligent PowerOff of Carriers in Interval Type the Same Coverage

0~17

N/A

None

Intelligent PowerOff of Carriers in Enumeration Type the Same Coverage

OFF(Off), ON(On)

OFF~0, ON~1

None

Intelligent PowerOff of Carriers in Compound Type the Same Coverage

00:00:00~23:59:59

N/A

None

Intelligent PowerOff of Carriers in Compound Type the Same Coverage

00:00:00~23:59:59

N/A

None

Intelligent PowerOff of Carriers in Interval Type the Same Coverage

0~100

N/A

Intelligent PowerOff of Carriers in Interval Type the Same Coverage

0~100

N/A

Intelligent PowerOff of Carriers in Interval Type the Same Coverage

0~100

N/A

Intelligent PowerOff of Carriers in Interval Type the Same Coverage

0~100

N/A

None

Interval Type

0~17

N/A

None

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

ms

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Interval Type

1~8

N/A

None

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

r1(1), r2(2), r4(4), r8(8), r16(16), r32(32), r64(64), Infinity(Infinity)

r1~0, r2~1, r4~2, r8~3, r16~4, r32~5, None r64~6, Infinity~7

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

SAME_AS_TRIG_ QUAN(Same as Trig Quan), BOTH

SAME_AS_TRIG_ None QUAN~0, BOTH~1

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

RSRP, RSRQ

RSRP~0, RSRQ~1 None

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Interval Type

0~30

N/A

0.5dB

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

0ms~0, 40ms~1, 64ms~2, 80ms~3, 100ms~4, 128ms~5, 160ms~6, 256ms~7, 320ms~8, 480ms~9, 512ms~10, 640ms~11, 1024ms~12, 1280ms~13, 2560ms~14, 5120ms~15

ms

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Interval Type

-30~30

N/A

0.5dB

None

Interval Type

0~17

N/A

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

ULSCH_STRATEG Y_EPF(EPF), ULSCH_STRATEG Y_MAX_CI(MAX_CI ), ULSCH_STRATEG Y_PF(PF), ULSCH_STRATEG Y_RR(RR)

ULSCH_STRATEG Y_EPF~0, ULSCH_STRATEG Y_MAX_CI~1, None ULSCH_STRATEG Y_PF~2, ULSCH_STRATEG Y_RR~3

UL Synchronous HARQ

Enumeration Type

ADAPTIVE_HARQ_ SW_ON(On), ADAPTIVE_HARQ_ SW_OFF(Off), ADAPTIVE_HARQ_ SW_SEMI_ON(Se miOn)

ADAPTIVE_HARQ_ SW_ON~0, ADAPTIVE_HARQ_ None SW_OFF~1, ADAPTIVE_HARQ_ SW_SEMI_ON~2

AMC

Interval Type

1~99

N/A

0.01

Dynamic Scheduling

Interval Type

0~100

N/A

Dynamic Scheduling

Interval Type

1~40

N/A

ms

Dynamic Scheduling

Interval Type

45~1500

N/A

byte

Basic Scheduling Enhanced Scheduling

Enumeration Type

HOPPING_OFF(Ho pping off), HOPPING_TYPE1( Hopping Type 1), HOPPING_TYPE2( Hopping Type 2), HOPPING_TYPE2_ RANDOM(Hopping Type 2 Random)

HOPPING_OFF~0, HOPPING_TYPE1~ 1, HOPPING_TYPE2~ None 2, HOPPING_TYPE2_ RANDOM~3

Dynamic Scheduling Interval Type Admission Control Congestion Control

0~100

N/A

Dynamic Scheduling

Interval Type

16~15000

N/A

bit

Dynamic Scheduling

Interval Type

2~3

N/A

None

Intelligent PowerOff of Carriers in Interval Type the Same Coverage of UMTS Network

0~17

N/A

None

Intelligent PowerOff of Carriers in Enumeration Type the Same Coverage of UMTS Network

OFF(Off), ON(On)

OFF~0, ON~1

None

Intelligent PowerOff of Carriers in Compound Type the Same Coverage of UMTS Network

00:00:00~23:59:59

N/A

None

Intelligent PowerOff of Carriers in Compound Type the Same Coverage of UMTS Network

00:00:00~23:59:59

N/A

None

Intelligent PowerOff of Carriers in Interval Type the Same Coverage of UMTS Network

0~5000

N/A

None

Intelligent PowerOff of Carriers in Interval Type the Same Coverage of UMTS Network

0~100

N/A

Intelligent PowerOff of Carriers in Interval Type the Same Coverage of UMTS Network

0~100

N/A

None

Interval Type

0~17

N/A

None

3GPP R8 Specifications Random Access Procedure

Bit Field Type

RachAdjSwitch(Rac hAdjSwitch), HoRaSwitch(HoRa Switch), UnsyncRaSwitch(U nsyncRaSwitch), MaksIdxSwitch(Mak sIdxSwitch), BackOffSwitch(Bac kOffSwitch)

RachAdjSwitch~0, HoRaSwitch~1, UnsyncRaSwitch~2, None MaksIdxSwitch~3, BackOffSwitch~4

3GPP R8 Specifications

Bit Field Type

SrsSubframeRecfS SrsSubframeRecfS witch(SrsSubframe None witch~0 RecfSwitch)

3GPP R8 Specifications

Bit Field Type

PucchSwitch(Pucch PucchSwitch~0 Switch)

None

Active Queue Bit Field Type Management(AQM)

AqmAlgoSwitch

AqmAlgoSwitch~0

None

UL 2x2 MU-MIMO CQI Adjustment Dynamic Scheduling

Bit Field Type

CqiAdjAlgoSwitch, StepVarySwitch

CqiAdjAlgoSwitch~ 0, None StepVarySwitch~1

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Adaptive Power Consumption

Bit Field Type

DynAdjVoltSwitch(D ynamic Adjust DynAdjVoltSwitch~0 None Voltage Switch)

3GPP R8 Specifications Admission Control Congestion Control Bit Field Type Radio/transport Resource Preemption

DlSwitch(dlCacSwit ch), UlSwitch(ulCacSwit ch), DlPredictSwitch(dlC acPredictSwitch), UlPredictSwitch(ulC acPredictSwitch), GbrUsageSwitch(G brUsedPRbCheckS witch), DlLdcSwitch(dlLdcS witch), UlLdcSwitch(ulLdcS witch), RelDrbSwitch(LdcD rbRelSwitch), PreemptionSwitch( PreemptionSwitch)

DlSwitch~0, UlSwitch~1, DlPredictSwitch~2, UlPredictSwitch~3, GbrUsageSwitch~4, None DlLdcSwitch~5, UlLdcSwitch~6, RelDrbSwitch~7, PreemptionSwitch~ 8

3GPP R8 Specifications Intra-LTE Load Balancing Bit Field Type Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN

IntraFreqMlbSwitch( IntraFreqMlbSwitch) , InterFreqMlbSwitch( InterFreqMlbSwitch) , UtranMlbSwitch(Utr anMlbSwitch), GeranMlbSwitch(Ge ranMlbSwitch), CdmaMlbSwitch(Cd maMlbSwitch), IntraFreqIdleMlbSwi tch(IntraFreqIdleMlb Switch)

IntraFreqMlbSwitch ~0, InterFreqMlbSwitch ~1, UtranMlbSwitch~2, None GeranMlbSwitch~3, CdmaMlbSwitch~4, IntraFreqIdleMlbSwi tch~5

Physical Channel Management Broadcast of Bit Field Type system information Dynamic Downlink Power Allocation

PdschSpsPcSwitch PdschSpsPcSwitch, ~0, PhichInnerLoopPcS PhichInnerLoopPcS None witch, witch~1, PdcchPcSwitch PdcchPcSwitch~2

Broadcast of system information Bit Field Type Uplink Power Control

CloseLoopSpsSwitc h, InnerLoopPuschSwi tch, PhSinrTarUpdateS witch, InnerLoopPucchSwi tch, OiSinrTarUpdateSw itch, PowerSavingSwitch

CloseLoopSpsSwitc h~0, InnerLoopPuschSwi tch~1, PhSinrTarUpdateS witch~2, None InnerLoopPucchSwi tch~3, OiSinrTarUpdateSw itch~4, PowerSavingSwitch ~5

Single Streaming Beamforming Dual streaming Beamforming BEAMFORMING AND MIMO ADAPTIVE SWITCH (Test Feature)

Bit Field Type

BfSwitch

BfSwitch~0

None

Basic Scheduling Enhanced Scheduling

Bit Field Type

FreqSelSwitch(Freq SelSwitch), ServiceDiffSwitch(S erviceDiffSwitch), SpsSchSwitch(Sps SchSwitch), MBSFNShutDownS witch(MBSFNShutD ownSwitch)

FreqSelSwitch~0, ServiceDiffSwitch~1 , SpsSchSwitch~2, None MBSFNShutDownS witch~3

Basic Scheduling Enhanced Scheduling TTI Bundling VoIP Semipersistent Scheduling / VoIP Semi-persistent Scheduling 800M Selfinterference Cancellation

Bit Field Type

SpsSchSwitch(Sps SchSwitch), SinrAdjustSwitch(Si nrAdjustSwitch), PreAllocationSwitch (PreAllocationSwitc h), UlVmimoSwitch(UlV mimoSwitch), TtiBundlingSwitch(T tiBundlingSwitch), ImIcSwitch(ImIcSwit ch)

SpsSchSwitch~0, SinrAdjustSwitch~1, PreAllocationSwitch ~2, None UlVmimoSwitch~3, TtiBundlingSwitch~ 4, ImIcSwitch~5

3GPP R8 Specifications Admission Control Basic Scheduling

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Intra-LTE Load Balancing

Bit Field Type

FreqPriorIFHOSwitc h(FreqPriorIFHOSw itch), FreqPriorIFBlindHO Switch(FreqPriorIFB lindHOSwitch)

FreqPriorIFHOSwitc h~0, None FreqPriorIFBlindHO Switch~1

3GPP R8 Specifications

Bit Field Type

MuBfSwitch(MuBfS MuBfSwitch~0 witch)

None

Distance Based Inter-frequency Handover Distance based Inter-RAT handover Enumeration Type to UTRAN Distance based Inter-RAT handover to GERAN

OFF(Off), ON(On)

OFF~0, ON~1

None

3GPP R8 Specifications Enumeration Type Broadcast of system information

ACBAR_SWITCH_ DYNAMIC(dynamic configuration), ACBAR_SWITCH_ STATIC(static configuration), ACBAR_SWITCH_ DISABLE(Disable)

ACBAR_SWITCH_ DYNAMIC~0, ACBAR_SWITCH_ None STATIC~1, ACBAR_SWITCH_ DISABLE~2

3GPP R8 Specifications

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

0~17

N/A

None

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

MODE1(DL band division scheme No.1), MODE2(DL band division scheme No.2), MODE3(DL band division scheme No.3), INVALID(Invalid DL band division scheme)

MODE1~0, MODE2~1, MODE3~2, INVALID~255

None

Dynamic Downlink Power Allocation

Interval Type

0~17

N/A

None

Dynamic Downlink Power Allocation

Interval Type

-150~150

N/A

0.1dB

Dynamic Downlink Power Allocation

Interval Type

0~17

N/A

None

Dynamic Downlink Power Allocation

Enumeration Type

PA_NEG6(-6dB), PA_NEG4DOT77(4.77dB), PA_NEG3(- PA_NEG6~0, 3dB), PA_NEG4DOT77~1 PA_NEG1DOT77(- , PA_NEG3~2, dB 1.77dB), PA_NEG1DOT77~3 PA_0(0dB), , PA_0~4, PA_1~5, PA_1(1dB), PA_2~6, PA_3~7 PA_2(2dB), PA_3(3dB) PA_NEG6(-6dB), PA_NEG4DOT77(4.77dB), PA_NEG3(- PA_NEG6~0, 3dB), PA_NEG4DOT77~1 PA_NEG1DOT77(- , PA_NEG3~2, dB 1.77dB), PA_NEG1DOT77~3 PA_0(0dB), , PA_0~4, PA_1~5, PA_1(1dB), PA_2~6, PA_3~7 PA_2(2dB), PA_3(3dB)

Dynamic Downlink Power Allocation

Enumeration Type

Dynamic Downlink Power Allocation

Interval Type

0~17

N/A

None

Dynamic Downlink Power Allocation

Interval Type

-150~150

N/A

0.1dBm

None

Interval Type

0~17

N/A

None

Basic Scheduling Enhanced Scheduling

Enumeration Type

DLSCH_PRI_TYPE _EPF(EPF), DLSCH_PRI_TYPE _PF(PF), DLSCH_PRI_TYPE _MAX_CI(MAX C/I), DLSCH_PRI_TYPE _RR(RR)

DLSCH_PRI_TYPE _EPF~0, DLSCH_PRI_TYPE _PF~1, None DLSCH_PRI_TYPE _MAX_CI~2, DLSCH_PRI_TYPE _RR~3

Dynamic Scheduling Interval Type Admission Control Congestion Control

0~100

N/A

P2P Throttling

Interval Type

0~100

N/A

0.01

P2P Throttling

Interval Type

0~100

N/A

0.01

Dynamic Scheduling Enumeration Type Admission Control Congestion Control

SW_MAX_SM_RA NK_1(), SW_MAX_SM_RA NK_2(), SW_MAX_SM_RA NK_4()

SW_MAX_SM_RA NK_1~0, SW_MAX_SM_RA NK_2~1, SW_MAX_SM_RA NK_4~2

None

None

Interval Type

0~17

N/A

None

3GPP R8 Specifications Intra-LTE Load Balancing

Interval Type

1~100

N/A

3GPP R8 Specifications Intra-LTE Load Balancing

Interval Type

1~100

N/A

3GPP R8 Specifications Inter-RAT Load Interval Type Sharing to UTRAN Inter-RAT Load Sharing to GERAN

1~100

N/A

3GPP R8 Specifications Intra-LTE Load Balancing Enumeration Type Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN

LOAD_EXCHANGE _PERIOD_1S(1s), LOAD_EXCHANGE _PERIOD_2S(2s), LOAD_EXCHANGE _PERIOD_5S(5s), LOAD_EXCHANGE _PERIOD_10S(10s)

LOAD_EXCHANGE _PERIOD_1S~0, LOAD_EXCHANGE _PERIOD_2S~1, s LOAD_EXCHANGE _PERIOD_5S~2, LOAD_EXCHANGE _PERIOD_10S~3

3GPP R8 Specifications Intra-LTE Load Balancing Interval Type Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN

0~50

N/A

3GPP R8 Specifications Intra-LTE Load Balancing Interval Type Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN

1~50

N/A

None

Interval Type

0~17

N/A

None

3GPP R8 Specifications

Enumeration Type

CONGREG_LV4, CONGREG_LV8

CONGREG_LV4~2, None CONGREG_LV8~3

3GPP R8 Specifications ADAPATIVE CCE AGGREGATION

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

3GPP R8 Specifications

Interval Type

1~4

N/A

None

3GPP R8 Specifications

Interval Type

0~100

N/A

3GPP R8 Specifications

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

3GPP R8 Specifications REDUCE Interval Type SCHEDULE USER IN EACH TTI

1~100

N/A

3GPP R8 Specifications

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Interval Type

0~17

N/A

None

None

Interval Type

0~50

N/A

None

Sleeping Cell Detection

Interval Type

0~17

N/A

None

Sleeping Cell Detection

Compound Type

00:00:00~23:59:59

N/A

None

Sleeping Cell Detection

Compound Type

00:00:00~23:59:59

N/A

None

Sleeping Cell Detection

Interval Type

0~72

N/A

None

Interval Type

0~17

N/A

None

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

MODE1(UL band division scheme No.1), MODE2(UL band division scheme No.2), MODE3(UL band division scheme No.3), INVALID(Invalid UL band division scheme)

MODE1~1, MODE2~2, MODE3~3, INVALID~255

None

None

Interval Type

0~17

N/A

None

None

Interval Type

0~9

N/A

None

None

Enumeration Type

TM1(TM1), TM2(TM2), TM7(TM7), TM8(TM8)

TM1~0, TM2~1, TM7~6, TM8~7

None

None

Interval Type

0~100

N/A

None

None

Interval Type

0~100

N/A

None

None

Interval Type

0~10000

N/A

0.01mW

None

Interval Type

0~10000

N/A

0.01mW

None

Interval Type

0~1200

N/A

None

None

Interval Type

0~1200

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

Broadcast of Enumeration Type system information

MOD_PERIOD_CO EFF_N2(2), MOD_PERIOD_CO EFF_N4(4), MOD_PERIOD_CO EFF_N8(8), MOD_PERIOD_CO EFF_N16(16)

MOD_PERIOD_CO EFF_N2~0, MOD_PERIOD_CO EFF_N4~1, None MOD_PERIOD_CO EFF_N8~2, MOD_PERIOD_CO EFF_N16~3

None

Interval Type

0~17

N/A

None

Physical Channel Management Broadcast of Interval Type system information Dynamic Downlink Power Allocation

-3175~3175

N/A

0.005dB

Physical Channel Management Broadcast of Interval Type system information Dynamic Downlink Power Allocation

-3175~3175

N/A

0.005dB

Physical Channel Management Broadcast of Interval Type system information Dynamic Downlink Power Allocation

-3175~3175

N/A

0.005dB

Physical Channel Management Broadcast of Interval Type system information Dynamic Downlink Power Allocation

-3175~3175

N/A

0.005dB

Physical Channel Management Broadcast of system information Interval Type Paging Dynamic Downlink Power Allocation Physical Channel Management Broadcast of system information Interval Type Random Access Procedure Dynamic Downlink Power Allocation

-3175~3175

N/A

0.005dB

-3175~3175

N/A

0.005dB

None

Interval Type

-3175~3175

N/A

0.005dB

None

Interval Type

0~17

N/A

None

Physical Channel Management Broadcast of Interval Type system information Dynamic Downlink Power Allocation

-600~500

N/A

0.1dBm

Physical Channel Management Broadcast of Interval Type system information Dynamic Downlink Power Allocation

0~3

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications

Enumeration Type

DB0_PWR_RAMPI NG_STEP(0dB), DB2_PWR_RAMPI NG_STEP(2dB), DB4_PWR_RAMPI NG_STEP(4dB), DB6_PWR_RAMPI NG_STEP(6dB)

DB0_PWR_RAMPI NG_STEP~0, DB2_PWR_RAMPI NG_STEP~1, dB DB4_PWR_RAMPI NG_STEP~2, DB6_PWR_RAMPI NG_STEP~3

3GPP R8 Specifications

Enumeration Type

DBM_120(120dBm), DBM_118(118dBm), DBM_116(116dBm), DBM_120~0, DBM_114(DBM_118~1, 114dBm), DBM_116~2, DBM_112(DBM_114~3, 112dBm), DBM_112~4, DBM_110(DBM_110~5, 110dBm), DBM_108~6, DBM_108(DBM_106~7, 108dBm), DBM_104~8, DBM_106(DBM_102~9, 106dBm), DBM_100~10, DBM_104(DBM_98~11, 104dBm), DBM_96~12, DBM_102(DBM_94~13, 102dBm), DBM_92~14, DBM_100(DBM_90~15 100dBm), DBM_98(98dBm), DBM_96(96dBm), DBM_94(94dBm), DBM_92(92dBm), DBM_90(90dBm)

dBm

3GPP R8 Specifications Transport Channel Management

Enumeration Type

B56_MSG_SIZE_G ROUPA(56bits), B144_MSG_SIZE_ GROUPA(144bits), B208_MSG_SIZE_ GROUPA(208bits), B256_MSG_SIZE_ GROUPA(256bits)

B56_MSG_SIZE_G ROUPA~0, B144_MSG_SIZE_ GROUPA~1, bit B208_MSG_SIZE_ GROUPA~2, B256_MSG_SIZE_ GROUPA~3

3GPP R8 Specifications

Interval Type

0~94

N/A

None

3GPP R8 Specifications

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications

Interval Type

0~63

N/A

None

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Physical Channel Management

Enumeration Type

SC0(0), SC1(1), SC2(2), SC3(3), SC4(4), SC5(5), SC6(6), SC7(7), SC8(8), SC9(9), SC10(10), SC11(11), SC12(12), SC13(13), SC14(14)

SC0~0, SC1~1, SC2~2, SC3~3, SC4~4, SC5~5, SC6~6, SC7~7, SC8~8, SC9~9, None SC10~10, SC11~11, SC12~12, SC13~13, SC14~14

3GPP R8 Specifications Physical Channel Management

Enumeration Type

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Physical Channel Management

Enumeration Type

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications Physical Channel Management

Enumeration Type

ACCESS_FIRST(A ccess First), ACCESS_FIRST~0, EXPERIENCE_FIR EXPERIENCE_FIR None ST(Experience ST~1 First)

3GPP R8 Specifications Physical Channel Management

Enumeration Type

BW0(BW0), BW1(BW1), BW2(BW2), BW3(BW3), BW4(BW4), BW5(BW5), BW6(BW6), BW7(BW7)

BW0~0, BW1~1, BW2~2, BW3~3, BW4~4, BW5~5, BW6~6, BW7~7

None

None

Interval Type

0~17

N/A

None

Physical Channel Management Enumeration Type Broadcast of system information

NORMAL, EXTENDED

NORMAL~0, EXTENDED~1

None

Physical Channel Management Enumeration Type Broadcast of system information

ONE_SIXTH, HALF, ONE, TWO

ONE_SIXTH~0, HALF~1, ONE~2, TWO~3

None

None

Interval Type

0~17

N/A

None

Broadcast of system information Enumeration Type Paging

rf32(32 radio frames), rf64(64 radio frames), rf128(128 radio frames), rf256(256 radio frames)

rf32~0, rf64~1, rf128~2, rf256~3

None

Broadcast of system information Enumeration Type Paging

FOURT, TWOT, ONET, HALFT, QUARTERT, ONE_EIGHTT, ONE_SIXTEENTHT , ONE_THIRTY_SEC ONDT

FOURT~0, TWOT~1, ONET~2, HALFT~3, QUARTERT~4, ONE_EIGHTT~5, None ONE_SIXTEENTHT ~6, ONE_THIRTY_SEC ONDT~7

None

Interval Type

0~17

N/A

None

Physical Channel Management Interval Type Broadcast of system information

1~4

N/A

None

Physical Channel Management Enumeration Type Broadcast of system information

INTER_SUB_FRA ME(Inter), INTRA_AND_INTE R_SUB_FRAME(Int er And Intra)

INTER_SUB_FRA ME~0, None INTRA_AND_INTE R_SUB_FRAME~1

Physical Channel Management Interval Type Broadcast of system information

0~98

N/A

RB

Physical Channel Management Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Physical Channel Management Interval Type Broadcast of system information

0~29

N/A

None

Physical Channel Management Enumeration Type Broadcast of system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Physical Channel Management Interval Type Broadcast of system information

0~7

N/A

None

UL 64QAM

Enumeration Type

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

3GPP R8 Specifications

Interval Type

0~17

N/A

None

3GPP R8 Specifications Physical Channel Management

Enumeration Type

DS1_DELTA_SHIF T(ds1), DS2_DELTA_SHIF T(ds2), DS3_DELTA_SHIF T(ds3)

DS1_DELTA_SHIF T~0, DS2_DELTA_SHIF None T~1, DS3_DELTA_SHIF T~2

3GPP R8 Specifications Physical Channel Management

Interval Type

0~100

N/A

None

3GPP R8 Specifications Physical Channel Management

Interval Type

0~20

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

6~32 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type CDMA2000

6~32 characters

N/A

None

PS Inter-RAT Mobility between EUTRAN and Enumeration Type CDMA2000 Inter-RAT ANR

PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

PERMIT_RMV_EN UM(Permit ANR Remove), FORBID_RMV_EN UM(Forbid ANR Remove)

PERMIT_RMV_EN UM~0, None FORBID_RMV_EN UM~1

Mobility Management

Interval Type

0~32

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Automatic Neighbour Relation Character String (ANR) Type Inter-RAT ANR

0~99 characters

N/A

None

Automatic Neighbour Relation Character String (ANR) Type Inter-RAT ANR

0~99 characters

N/A

None

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EUTRAN and CDMA2000 Cell Selection and Enumeration Type Reselection / Cell Selection and Reselection Inter-RAT ANR

bc0~0, bc1~1, bc2~2, bc3~3, bc0, bc1, bc2, bc3, bc4~4, bc5~5, bc4, bc5, bc6, bc7, bc6~6, bc7~7, bc8, bc9, bc10, bc8~8, bc9~9, None bc11, bc12, bc13, bc10~10, bc11~11, bc14, bc15, bc16, bc12~12, bc13~13, bc17 bc14~14, bc15~15, bc16~16, bc17~17

PS Inter-RAT Mobility between EUTRAN and CDMA2000 Cell Selection and Interval Type Reselection / Cell Selection and Reselection Inter-RAT ANR

0~2047

N/A

None

PS Inter-RAT Mobility between EUTRAN and Interval Type CDMA2000 Inter-RAT ANR

-15~15

N/A

dB

3GPP R8 Specifications PS Inter-RAT Enumeration Type Mobility between EUTRAN and CDMA2000

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications PS Inter-RAT Interval Type Mobility between EUTRAN and CDMA2000

0~15

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~1048575

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~255

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~65535

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

1~65533,65535

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Interval Type

0~268435455

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type CDMA2000

6~32 characters

N/A

None

PS Inter-RAT Mobility between EUTRAN and CDMA2000 Cell Selection and Enumeration Type Reselection / Cell Selection and Reselection Inter-RAT ANR PS Inter-RAT Mobility between EUTRAN and CDMA2000 Cell Selection and Interval Type Reselection / Cell Selection and Reselection Inter-RAT ANR

bc0~0, bc1~1, bc2~2, bc3~3, bc0, bc1, bc2, bc3, bc4~4, bc5~5, bc4, bc5, bc6, bc7, bc6~6, bc7~7, bc8, bc9, bc10, bc8~8, bc9~9, None bc11, bc12, bc13, bc10~10, bc11~11, bc14, bc15, bc16, bc12~12, bc13~13, bc17 bc14~14, bc15~15, bc16~16, bc17~17

0~2047

N/A

None

3GPP R8 Specifications PS Inter-RAT Mobility between EUTRAN and Interval Type CDMA2000 Cell Selection and Reselection / Cell Selection and Reselection

0~511

N/A

None

PS Inter-RAT Mobility between EUTRAN and Enumeration Type CDMA2000 Cell Selection and Reselection

CDMA2000_HRPD( CDMA2000_HRPD) , CDMA2000_1XRTT (CDMA2000_1XRT T)

CDMA2000_HRPD ~0, None CDMA2000_1XRTT ~1

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

3 characters

N/A

None

RAN Sharing with Common Carrier RAN Sharing with Dedicated Carrier

Character String Type

2~3 characters

N/A

None

PS Inter-RAT Mobility between EUTRAN and CDMA2000 Character String Cell Selection and Type Reselection / Cell Selection and Reselection Inter-RAT ANR

0~99 characters

N/A

None

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type CDMA2000

6~32 characters

N/A

None

PS Inter-RAT Mobility between EUTRAN and Enumeration Type CDMA2000 Inter-RAT ANR

PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

PERMIT_RMV_EN UM(Permit ANR Remove), FORBID_RMV_EN UM(Forbid ANR Remove)

PERMIT_RMV_EN UM~0, None FORBID_RMV_EN UM~1

Mobility Management

Interval Type

0~32

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Automatic Neighbour Relation Character String (ANR) Type Inter-RAT ANR

0~99 characters

N/A

None

Automatic Neighbour Relation Character String (ANR) Type Inter-RAT ANR

0~99 characters

N/A

None

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EUTRAN and CDMA2000 Cell Selection and Enumeration Type Reselection / Cell Selection and Reselection Inter-RAT ANR

bc0~0, bc1~1, bc2~2, bc3~3, bc0, bc1, bc2, bc3, bc4~4, bc5~5, bc4, bc5, bc6, bc7, bc6~6, bc7~7, bc8, bc9, bc10, bc8~8, bc9~9, None bc11, bc12, bc13, bc10~10, bc11~11, bc14, bc15, bc16, bc12~12, bc13~13, bc17 bc14~14, bc15~15, bc16~16, bc17~17

PS Inter-RAT Mobility between EUTRAN and CDMA2000 Interval Type Cell Selection and Reselection / Cell Selection and Reselection

0~7

N/A

None

Cell Selection and Reselection

Interval Type

0~63

N/A

dB

Cell Selection and Reselection

Interval Type

0~63

N/A

dB

PS Inter-RAT Mobility between E- Character String UTRAN and Type GERAN

3 characters

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type GERAN

2~3 characters

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~65535

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

1~65533,65535

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and GERAN

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~255

N/A

None

PS Inter-RAT Mobility between EUTRAN and GERAN SRVCC to GERAN CS Fallback to GERAN Enumeration Type Service based interRAT handover to GERAN Distance based inter-RAT handover to GERAN

GSM_dcs1800, GSM_pcs1900

GSM_dcs1800~0, GSM_pcs1900~1

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~1023

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~7

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~7

N/A

None

PS Inter-RAT Mobility between EUTRAN and GERAN Enumeration Type Service based interRAT handover to GERAN

DTM_AVAILABLE~ DTM_AVAILABLE, 0, DTM_NOT_AVAILA None DTM_NOT_AVAILA BLE BLE~1

PS Inter-RAT Mobility between E- Character String UTRAN and Type GERAN

0~99 characters

N/A

None

PS Inter-RAT Mobility between EUTRAN and GERAN Enumeration Type Service based interRAT handover to GERAN

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type GERAN

3 characters

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type GERAN

2~3 characters

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

1~65533,65535

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and GERAN

0~65535

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

PERMIT_RMV_EN UM(Permit ANR Remove), FORBID_RMV_EN UM(Forbid ANR Remove) PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_RMV_EN UM~0, None FORBID_RMV_EN UM~1

Inter-RAT ANR

Enumeration Type

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Mobility Management

Interval Type

0~32

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Automatic Neighbour Relation Character String (ANR) Type Inter-RAT ANR

0~99 characters

N/A

None

Automatic Neighbour Relation Character String (ANR) Type Inter-RAT ANR

0~99 characters

N/A

None

Flash CS Fallback to GERAN

Interval Type

0~1048575

N/A

None

Flash CS Fallback to GERAN

Character String Type

0~32 characters

N/A

None

Flash CS Fallback to GERAN

Character String Type

0~32 characters

N/A

None

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EUTRAN and Interval Type GERAN Inter-RAT ANR

0~31

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and GERAN

GSM, GPRS, EDGE

GSM~0, GPRS~1, EDGE~2

None

PS Inter-RAT Mobility between EUTRAN and GERAN Interval Type Cell Selection and Reselection / Cell Selection and Reselection

0~1023

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and GERAN

GSM_dcs1800, GSM_pcs1900

GSM_dcs1800~0, GSM_pcs1900~1

None

Cell Selection and Reselection / Cell Selection and Reselection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Reselection

Interval Type

0~7

N/A

None

Cell Selection and Reselection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Reselection

Interval Type

0~39

N/A

dBm

Cell Selection and Reselection

Interval Type

0~45

N/A

2dBm

Cell Selection and Reselection

Interval Type

0~31

N/A

2dB

Cell Selection and Reselection

Interval Type

0~31

N/A

2dB

PS Inter-RAT Mobility between EUTRAN and Interval Type GERAN Inter-RAT ANR

-15~15

N/A

dB

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~255

N/A

None

None

Interval Type

0~17

N/A

None

Broadcast of system information PS Inter-RAT Interval Type Mobility between EUTRAN and GERAN

0~31

N/A

None

Broadcast of system information Interval Type Inter-RAT ANR

0~1023

N/A

None

None

Interval Type

0~17

N/A

None

Cell Selection and Re-selection Coverage Based Intra-frequency Handover

Interval Type

0~503

N/A

None

Cell Selection and Re-selection Coverage Based Intra-frequency Handover

Character String Type

0~99 characters

N/A

None

Cell Selection and Re-selection Coverage Based Intra-frequency Handover

Enumeration Type

n1(n1), n4(n4), n8(n8), n12(n12), n16(n16), n24(n24), n32(n32), n48(n48), n64(n64), n84(n84), n96(n96), n128(n128), n168(n168), n252(n252), n504(n504)

n1~0, n4~1, n8~2, n12~3, n16~4, n24~5, n32~6, n48~7, n64~8, None n84~9, n96~10, n128~11, n168~12, n252~13, n504~14

None

Interval Type

0~17

N/A

None

Coverage Based Intra-frequency Handover

Character String Type

3 characters

N/A

None

Coverage Based Intra-frequency Handover

Character String Type

2~3 characters

N/A

None

Coverage Based Intra-frequency Handover

Interval Type

0~1048575

N/A

None

Coverage Based Intra-frequency Handover

Interval Type

0~255

N/A

None

Coverage Based Intra-frequency Handover Enumeration Type Mobility Robust Optimization (MRO)

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Cell Selection and Re-selection

Enumeration Type

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Coverage Based Intra-frequency Handover Enumeration Type Automatic Neighbour Relation (ANR)

PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Automatic Neighbour Relation Enumeration Type (ANR)

PERMIT_RMV_EN UM(Permit ANR Remove), FORBID_RMV_EN UM(Forbid ANR Remove)

PERMIT_RMV_EN UM~0, None FORBID_RMV_EN UM~1

Automatic Neighbour Relation Enumeration Type (ANR)

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Coverage Based Intra-frequency Handover Character String Automatic Type Neighbour Relation (ANR)

0~99 characters

N/A

None

Coverage Based Intra-frequency Handover Character String Automatic Type Neighbour Relation (ANR)

0~99 characters

N/A

None

None

Interval Type

0~17

N/A

None

3GPP R8 Specifications Cell Selection and Reselection Coverage Based Inter-frequency Handover

Interval Type

0~45589,64436~65 N/A 535

None

3GPP R8 Specifications Cell Selection and Re-selection Coverage Based Inter-frequency Handover

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

3GPP R8 Specifications Cell Selection and Reselection Coverage Based Inter-frequency Handover

Interval Type

18000~45589,6443 N/A 6~65535

None

Cell Selection and Re-selection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Reselection

Interval Type

0~7

N/A

None

Cell Selection and Re-selection

Interval Type

0~7

N/A

Cell Selection and Re-selection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Re-selection

Enumeration Type

0DOT25_ENUM(0.2 5), 0DOT5_ENUM(0.5) , 0DOT75_ENUM(0.7 5), 1DOT0_ENUM(1.0)

0DOT25_ENUM~0, 0DOT5_ENUM~1, None 0DOT75_ENUM~2, 1DOT0_ENUM~3

Cell Selection and Re-selection

Enumeration Type

0DOT25_ENUM(0.2 5), 0DOT5_ENUM(0.5) , 0DOT75_ENUM(0.7 5), 1DOT0_ENUM(1.0)

0DOT25_ENUM~0, 0DOT5_ENUM~1, None 0DOT75_ENUM~2, 1DOT0_ENUM~3

3GPP R8 Specifications Cell Selection and Re-selection Coverage Based Inter-frequency Handover

Enumeration Type

MBW6(1.4M), MBW15(3M), MBW25(5M), MBW50(10M), MBW75(15M), MBW100(20M)

MBW6~0, MBW15~1, MBW25~2, MBW50~3, MBW75~4, MBW100~5

MHz

3GPP R8 Specifications Cell Selection and Re-selection

Enumeration Type

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Cell Selection and Re-selection

Interval Type

0~31

N/A

2dB

Cell Selection and Re-selection

Interval Type

0~31

N/A

2dB

Cell Selection and Re-selection

Interval Type

-70~-22

N/A

2dBm

Cell Selection and Re-selection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Re-selection

Interval Type

-30~33

N/A

dBm

Cell Selection and Re-selection Coverage Based Inter-frequency Handover

Enumeration Type

BitString00(00), BitString01(01), BitString10(10), BitString11(11)

BitString00~0, BitString01~1, BitString10~2, BitString11~3

None

Cell Selection and Reselection Coverage Based Inter-frequency Handover

Enumeration Type

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Coverage Based Inter-frequency Handover

Enumeration Type

EventA3(EventA3), EventA3~0, EventA4(EventA4), EventA4~1, EventA5(EventA5) EventA5~2

None

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~31

N/A

dB

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~31

N/A

dB

Cell Selection and Reselection / Cell Selection and Reselection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Re-selection

Interval Type

-34~-3

N/A

dB

None

Interval Type

0~17

N/A

None

Cell Selection and Reselection Coverage Based Inter-frequency Handover

Interval Type

0~45589,64436~65 N/A 535

None

Cell Selection and Re-selection Coverage Based Inter-frequency Handover

Interval Type

0~503

N/A

None

Cell Selection and Re-selection Coverage Based Inter-frequency Handover

Character String Type

0~99 characters

N/A

None

Cell Selection and Re-selection Coverage Based Inter-frequency Handover

Enumeration Type

n1(n1), n4(n4), n8(n8), n12(n12), n16(n16), n24(n24), n32(n32), n48(n48), n64(n64), n84(n84), n96(n96), n128(n128), n168(n168), n252(n252), n504(n504)

n1~0, n4~1, n8~2, n12~3, n16~4, n24~5, n32~6, n48~7, n64~8, None n84~9, n96~10, n128~11, n168~12, n252~13, n504~14

None

Interval Type

0~17

N/A

None

Coverage Based Inter-frequency Handover

Character String Type

3 characters

N/A

None

Coverage Based Inter-frequency Handover

Character String Type

2~3 characters

N/A

None

Coverage Based Inter-frequency Handover

Interval Type

0~1048575

N/A

None

Coverage Based Inter-frequency Handover

Interval Type

0~255

N/A

None

Coverage Based Inter-frequency Handover Enumeration Type Mobility Robust Optimization (MRO)

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Cell Selection and Re-selection

Enumeration Type

dB-24(-24dB), dB22(-22dB), dB-20(20dB), dB-18(18dB), dB-16(16dB), dB-14(14dB), dB-12(12dB), dB-10(10dB), dB-8(-8dB), dB-6(-6dB), dB-5(5dB), dB-4(-4dB), dB-3(-3dB), dB-2(2dB), dB-1(-1dB), dB0(0dB), dB1(1dB), dB2(2dB), dB3(3dB), dB4(4dB), dB5(5dB), dB6(6dB), dB8(8dB), dB10(10dB), dB12(12dB), dB14(14dB), dB16(16dB), dB18(18dB), dB20(20dB), dB22(22dB), dB24(24dB)

dB-24~0, dB-22~1, dB-20~2, dB-18~3, dB-16~4, dB-14~5, dB-12~6, dB-10~7, dB-8~8, dB-6~9, dB5~10, dB-4~11, dB3~12, dB-2~13, dB1~14, dB0~15, dB dB1~16, dB2~17, dB3~18, dB4~19, dB5~20, dB6~21, dB8~22, dB10~23, dB12~24, dB14~25, dB16~26, dB18~27, dB20~28, dB22~29, dB24~30

Coverage Based Inter-frequency Handover Enumeration Type Automatic Neighbour Relation (ANR)

PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Automatic Neighbour Relation Enumeration Type (ANR)

PERMIT_RMV_EN UM(Permit ANR Remove), FORBID_RMV_EN UM(Forbid ANR Remove)

PERMIT_RMV_EN UM~0, None FORBID_RMV_EN UM~1

Coverage Based Inter-frequency Handover Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~32

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR)

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Coverage Based Inter-frequency Handover Character String Automatic Type Neighbour Relation (ANR)

0~99 characters

N/A

None

Coverage Based Inter-frequency Handover Character String Automatic Type Neighbour Relation (ANR)

0~99 characters

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Character String Type

3 characters

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Character String Type

2~3 characters

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

0~1048575

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

0~255

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

0~45589,64436~65 N/A 535

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

18000~45589,6443 N/A 6~65535

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover Cell Selection and Reselection

Interval Type

0~503

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Interval Type

0~65535

N/A

None

Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover

Character String Type

0~99 characters

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~31

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Character String Type

3 characters

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Character String Type

2~3 characters

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~7

N/A

None

None

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

3 characters

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

2~3 characters

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~268435455

N/A

None

PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN Inter-RAT ANR

PERMIT_HO_ENU M(Permit Ho), FORBID_HO_ENU M(Forbid Ho)

PERMIT_HO_ENU M~0, None FORBID_HO_ENU M~1

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

PERMIT_RMV_EN UM(Permit ANR Remove), FORBID_RMV_EN UM(Forbid ANR Remove)

PERMIT_RMV_EN UM~0, None FORBID_RMV_EN UM~1

Mobility Management

Interval Type

0~32

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR) Inter-RAT ANR

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

0~99 characters

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

0~99 characters

N/A

None

Flash CS Fallback to UTRAN

Interval Type

0~1048575

N/A

None

Flash CS Fallback to UTRAN

Interval Type

0~4095

N/A

None

Flash CS Fallback to UTRAN

Character String Type

0~32 characters

N/A

None

Flash CS Fallback to UTRAN

Character String Type

0~32 characters

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~17

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~16383

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Character String Type

3 characters

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Character String Type

2~3 characters

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~7

N/A

None

None

Interval Type

0~17

N/A

None

Broadcast of System Information PS Inter-RAT Mobility between E- Interval Type UTRAN and UTRAN Inter-RAT ANR

0~16383

N/A

None

PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN Cell Selection and Reselection PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN Inter-RAT ANR

R99, HSDPA, HSUPA, HSPA

R99~0, HSDPA~1, HSUPA~2, None HSPA~3

UTRAN_FDD, UTRAN_TDD

UTRAN_FDD~0, UTRAN_TDD~1

None

PS Inter-RAT Mobility between EUTRAN and Enumeration Type UTRAN Cell Selection and Reselection

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

PS Inter-RAT Mobility between EUTRAN and UTRAN Interval Type Cell Selection and Reselection Inter-RAT ANR

0~16383

N/A

None

Cell Selection and Reselection / Cell Selection and Reselection

Enumeration Type

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

Cell Selection and Reselection Interval Type Broadcast of system information

0~7

N/A

None

Cell Selection and Reselection

Interval Type

-50~33

N/A

dBm

PS Inter-RAT Mobility between EUTRAN and Interval Type UTRAN Inter-RAT ANR

-15~15

N/A

dB

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

-24~0

N/A

dB

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

-60~-13

N/A

2dBm

Cell Selection and Reselection

Interval Type

0~31

N/A

2dB

Cell Selection and Reselection

Interval Type

0~31

N/A

2dB

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~31

N/A

dB

Cell Selection and Reselection / Cell Selection and Reselection

Interval Type

0~31

N/A

dB

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

LOW_PRIORITY(L ow Priority), LOW_PRIORITY~1, None HIGH_PRIORITY(H HIGH_PRIORITY~2 igh Priority)

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

LOW_PRIORITY(L ow Priority), LOW_PRIORITY~1, None HIGH_PRIORITY(H HIGH_PRIORITY~2 igh Priority)

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

3 characters

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

2~3 characters

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~268435455

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

UTRAN_FDD, UTRAN_TDD

UTRAN_FDD~0, UTRAN_TDD~1

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~16383

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~16383

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~4095

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

NOT_CFG(Not configure), CFG(Configure)

NOT_CFG~0, CFG~1

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~255

N/A

None

PS Inter-RAT Mobility between EInterval Type UTRAN and UTRAN

0~511

N/A

None

PS Inter-RAT Mobility between EUTRAN and UTRAN SRVCC to UTRAN CS Fallback to UTRAN Interval Type Service based interRAT handover to UTRAN Distance based inter-RAT handover to UTRAN

1~65533,65535

N/A

None

PS Inter-RAT Mobility between E- Character String UTRAN and Type UTRAN

0~99 characters

N/A

None

PS Inter-RAT Mobility between EEnumeration Type UTRAN and UTRAN

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Automatic Neighbour Relation Interval Type (ANR)

0~100

N/A

Automatic Neighbour Relation Interval Type (ANR)

0~100

N/A

Automatic Neighbour Relation Interval Type (ANR)

1~10000

N/A

None

Automatic Neighbour Relation Interval Type (ANR)

1~10080

N/A

min

Automatic Neighbour Relation Enumeration Type (ANR)

r1(1), r2(2), r4(4), r8(8), r16(16), r32(32), r64(64), Infinity(Infinity)

r1~0, r2~1, r4~2, r8~3, r16~4, r32~5, None r64~6, Infinity~7

Automatic Neighbour Relation Enumeration Type (ANR)

120ms~0, 240ms~1, 480ms~2, 120ms, 240ms, 640ms~3, 480ms, 640ms, 1024ms~4, 1024ms, 2048ms, 2048ms~5, 5120ms, 10240ms, 5120ms~6, 1min, 6min, 12min, 10240ms~7, 30min, 60min 1min~8, 6min~9, 12min~10, 30min~11, 60min~12

None

Automatic Neighbour Relation Interval Type (ANR) Inter-RAT ANR

1~10080

N/A

min

Automatic Neighbour Relation Interval Type (ANR) Inter-RAT ANR

-130~-70

N/A

dBm

Automatic Neighbour Relation Interval Type (ANR)

1~200

N/A

None

Inter-RAT ANR

Interval Type

1~200

N/A

None

Automatic Neighbour Relation Interval Type (ANR)

1~10000

N/A

None

Inter-RAT ANR

Interval Type

1~10000

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR)

FREE(FREE), FREE~0, CONTROLLED(CO CONTROLLED~1 NTROLLED)

None

Automatic Neighbour Relation Interval Type (ANR)

1~50400

N/A

min

Automatic Neighbour Relation Interval Type (ANR)

1~10000

N/A

None

Automatic Neighbour Relation Enumeration Type (ANR)

OFF(Off), ON(On)

OFF~0, ON~1

None

Automatic Neighbour Relation Compound Type (ANR)

00:00:00~23:59:59

N/A

None

Automatic Neighbour Relation Compound Type (ANR)

00:00:00~23:59:59

N/A

None

Automatic Neighbour Relation Interval Type (ANR) Inter-RAT ANR

-120~-25

N/A

dBm

Automatic Neighbour Relation Interval Type (ANR) Inter-RAT ANR

-110~-48

N/A

dBm

Automatic Neighbour Relation Interval Type (ANR) Inter-RAT ANR

-63~0

N/A

0.5dB

Automatic Neighbour Relation Interval Type (ANR) Inter-RAT ANR

-63~0

N/A

0.5dB

Broadcast of Enumeration Type system information

BOOLEAN_FALSE( False), BOOLEAN_TRUE( True)

BOOLEAN_FALSE ~0, None BOOLEAN_TRUE~ 1

Broadcast of Compound Type system information

2000-0101T00:00:00.00000:00~2099-1231T23:59:59.00000:00

N/A

None

Broadcast of Interval Type system information Coverage Based Intra-frequency Handover Coverage Based Inter-frequency Handover PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and Bit Field Type CDMA2000 SRVCC to UTRAN SRVCC to GERAN CS Fallback to UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT Service based interRAT handover to UTRAN Inter-RAT Load Sharing to UTRAN Service based interRAT handover to GERAN

1~365 IntraFreqCoverHoS witch(IntraFreqCove rHoSwitch), InterFreqCoverHoS witch(InterFreqCove rHoSwitch), UtranCsfbSwitch(Ut ranCsfbSwitch), GeranCsfbSwitch(G eranCsfbSwitch), Cdma1xRttCsfbSwit ch(Cdma20001xRtt CsfbSwitch), UtranServiceHoSwit ch(UtranServiceHo Switch), GeranServiceHoSwi tch(GeranServiceH oSwitch), CdmaHrpdServiceH oSwitch(Cdma2000 HrpdServiceHoSwit ch), Cdma1xRttService HoSwitch(Cdma200 01xRttServiceHoSw itch), UlQualityInterRATH oSwitch(UlQualityInt erRATHoSwitch), InterPlmnHoSwitch( InterPlmnHoSwitch) , UtranFlashCsfbSwit

N/A

day

IntraFreqCoverHoS witch~0, InterFreqCoverHoS witch~1, UtranCsfbSwitch~2, GeranCsfbSwitch~3 , Cdma1xRttCsfbSwit ch~4, UtranServiceHoSwit ch~5, GeranServiceHoSwi tch~6, CdmaHrpdServiceH oSwitch~7, None Cdma1xRttService HoSwitch~8, UlQualityInterRATH oSwitch~9, InterPlmnHoSwitch ~10, UtranFlashCsfbSwit ch~11, GeranFlashCsfbSwi tch~12, ServiceBasedInterF reqHoSwitch~13, UlQualityInterFreqH oSwitch~14

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EUTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000 SRVCC to UTRAN SRVCC to GERAN CS Fallback to Bit Field Type UTRAN CS Fallback to GERAN CS Fallback to CDMA2000 1xRTT Service based interRAT handover to UTRAN Inter-RAT Load Sharing to UTRAN Inter-RAT Load Sharing to GERAN Service based interRAT handover to GERAN

EutranVoipCapSwit ch(EutranVoipCapS witch), UtranVoipCapSwitc h(UtranVoipCapSwi tch), GeranVoipCapSwitc h(GeranVoipCapSw itch), Cdma1xRttVoipCap Switch(Cdma1xRttV oipCapSwitch), UtranPsHoSwitch(U tranPsHoSwitch), GeranPsHoSwitch( GeranPsHoSwitch), CdmaHrpdNonOtpi misedHoSwitch(Cd maHrpdNonOtpimis edHoSwitch), CdmaHrpdOptimise dHoSwitch(CdmaHr pdOptimisedHoSwit ch), GeranNaccSwitch( GeranNaccSwitch), GeranCcoSwitch(G eranCcoSwitch), UtranSrvccSwitch(U tranSrvccSwitch), GeranSrvccSwitch( GeranSrvccSwitch), Cdma1xRttSrvccSw itch(Cdma1xRttSrvc

EutranVoipCapSwit ch~0, UtranVoipCapSwitc h~1, GeranVoipCapSwitc h~2, Cdma1xRttVoipCap Switch~3, UtranPsHoSwitch~4 , GeranPsHoSwitch~ 5, CdmaHrpdNonOtpi misedHoSwitch~6, CdmaHrpdOptimise dHoSwitch~7, GeranNaccSwitch~ None 8, GeranCcoSwitch~9, UtranSrvccSwitch~ 10, GeranSrvccSwitch~ 11, Cdma1xRttSrvccSw itch~12, UtranRedirectSwitc h~13, GeranRedirectSwitc h~14, CdmaHrpdRedirect Switch~15, Cdma1xRttRedirect Switch~16, BlindHoSwitch~17

Downlink Static Inter-Cell Interference Coordination Downlink Dynamic Inter-Cell Interference Coordination

Enumeration Type

DlIcicSwitch_OFF_ ENUM, DlIcicDynamicSwitc h_ON_ENUM, DlIcicStaticSwitch_ ON_ENUM, DlIcicReuse3Switch _ON_ENUM

DlIcicSwitch_OFF_ ENUM~0, DlIcicDynamicSwitc h_ON_ENUM~1, None DlIcicStaticSwitch_ ON_ENUM~2, DlIcicReuse3Switch _ON_ENUM~3

Automatic Neighbour Relation Bit Field Type (ANR) Inter-RAT ANR

IntraRatEventAnrS witch, IntraRatFastAnrSwit ch, IntraRatAnrAutoDel Switch, UtranEventAnrSwitc h, GeranEventAnrSwit ch, UtranFastAnrSwitch , GeranFastAnrSwitc h, CdmaFastAnrSwitc h, UtranAutoNrtDelete Switch, GeranAutoNrtDelet eSwitch, CdmaAutoNrtDelete Switch, ExtendIntraRatAnrS witch

IntraRatEventAnrS witch~0, IntraRatFastAnrSwit ch~1, IntraRatAnrAutoDel Switch~2, UtranEventAnrSwitc h~3, GeranEventAnrSwit ch~4, UtranFastAnrSwitch ~5, None GeranFastAnrSwitc h~6, CdmaFastAnrSwitc h~7, UtranAutoNrtDelete Switch~8, GeranAutoNrtDelet eSwitch~9, CdmaAutoNrtDelete Switch~10, ExtendIntraRatAnrS witch~11

PS Inter-RAT Mobility between EUTRAN and UTRAN PS Inter-RAT Mobility between EBit Field Type UTRAN and GERAN PS Inter-RAT Mobility between EUTRAN and CDMA2000

LoadBasedSwitch, GeranFlashRedirect Switch, UranFlashRedirectS witch

LoadBasedSwitch~ 0, GeranFlashRedirect None Switch~1, UranFlashRedirectS witch~2

Mobility Robust Bit Field Type Optimization (MRO)

IntraFreqMroSwitch( IntraFreqMroAlgoS witch), InterFreqMroSwitch( InterFreqMroAlgoS witch), UtranMroSwitch, GeranMroSwitch

IntraFreqMroSwitch ~0, InterFreqMroSwitch None ~1, UtranMroSwitch~2, GeranMroSwitch~3

3GPP R8 Specifications TCP Proxy Enhancer (TPE)

Bit Field Type

TpeAlgoSwitch

TpeAlgoSwitch~0

None

Uplink Dynamic Inter-Cell Interference Coordination

Bit Field Type

UlIcicIntraSwitch(Up link Intra-eNB ICIC UlIcicIntraSwitch~0 None switch)

Uplink Static InterCell Interference Coordination Uplink Dynamic Inter-Cell Interference Coordination

Enumeration Type

OFF(Off), STATIC(Static), OFF~0, STATIC~1, None DYNAMIC(Dynamic DYNAMIC~2 )

LoCation Services(LCS)

Bit Field Type

OtdoaSwitch(OTDO OtdoaSwitch~0 A switch)

None

None

Bit Field Type

UlUuFlowCtrlSwitch UlUuFlowCtrlSwitch (UU flow control None ~0 switch)

PCI Collision Detection & SelfOptimization

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Symbol Power Saving

Bit Field Type

SymbolShutdownS SymbolShutdownS witch(Symbol None witch~0 shutdown switch)

Flash CS Fallback to UTRAN Flash CS Fallback to GERAN

Bit Field Type

UTRAN_RIM_SWIT CH(UTRAN RIM Switch), GERAN_RIM_SWI TCH(GERAN RIM Switch)

UTRAN_RIM_SWIT CH~0, None GERAN_RIM_SWI TCH~1

Automatic Neighbour Relation Bit Field Type (ANR) Inter-RAT ANR

NBSLTEPLMNRou ndSwitch(NBSLTEP LMNRoundSwitch), NBSLTERANSharin gSwitch(NBSLTER ANSharingSwitch)

NBSLTEPLMNRou ndSwitch~0, None NBSLTERANSharin gSwitch~1

Mobility Management

Bit Field Type

UtranFreqLayerMea sSwitch(UtranFreqL ayerMeasSwitch), UtranFreqLayerBlin dSwitch(UtranFreqL ayerBlindSwitch)

UtranFreqLayerMea sSwitch~0, None UtranFreqLayerBlin dSwitch~1

None

Interval Type

1~65535

N/A

min

None

Interval Type

50~100

N/A

None

Interval Type

1~65535

N/A

min

None

Interval Type

49~99

N/A

RAN Sharing with Common Carrier

Interval Type

1~100

N/A

RAN Sharing with Common Carrier

Enumeration Type

SHARING(Sharing), SHARING~0, DEDICATE(Dedicat DEDICATE~1 e)

None

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

RAN Sharing with Common Carrier

Interval Type

0~100

N/A

Mobility Robust Interval Type Optimization(MRO)

1~70000

N/A

min

Mobility Robust Interval Type Optimization(MRO)

0~100

N/A

Mobility Robust Interval Type Optimization(MRO)

0~10000

N/A

None

Mobility Robust Interval Type Optimization(MRO)

1~60

N/A

Mobility Robust Interval Type Optimization(MRO)

0~100

N/A

Mobility Robust Interval Type Optimization(MRO)

0~100

N/A

Mobility Robust Interval Type Optimization(MRO)

-140~-44

N/A

dBm

Mobility Robust Interval Type Optimization(MRO)

-140~-44

N/A

dBm

None

Interval Type

0~9

N/A

None

None

Interval Type

0~100

N/A

None

Interval Type

0~100

N/A

None

Interval Type

0~50000

N/A

ms

None

Interval Type

0~50000

N/A

ms

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Radio Bearer Management

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Radio Bearer Management

Interval Type

0~4294967295

N/A

bit/s

Radio Bearer Management

Interval Type

1~255

N/A

ms

None

Interval Type

0~261120,275943~ N/A 307200

Ts

TCP Proxy Enhancer(TPE)

Interval Type

0~20

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

TCP Proxy Enhancer(TPE)

Interval Type

0~65535

N/A

None

Self-configuration

Interval Type

0~195

N/A

None

Self-configuration

Enumeration Type

SGW, X2eNodeB

SGW~0, X2eNodeB~1

None

Self-configuration

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

Self-configuration

Interval Type

0~127

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Enumeration Type

IP(IP)

IP~1

None

Self-configuration

Interval Type

0~15

N/A

None

Self-configuration

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

Self-configuration

Interval Type

0~15

N/A

None

Self-configuration

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), TUNNEL(Tunnel)

PPP~6, MPGRP~8, ETH~9, None ETHTRK~10, TUNNEL~15

Self-configuration Ipsec

Character String Type

1~15 characters

N/A

None

Self-configuration Ipsec

Interval Type

1~99

N/A

None

Self-configuration Ipsec

Character String Type

1~15 characters

N/A

None

Self-configuration Ipsec

Enumeration Type

X2(X2), S1(S1)

X2~0, S1~1

None

Self-configuration Ipsec

Enumeration Type

IKE_V1(IKE V1), IKE_V2(IKE V2)

IKE_V1~1, IKE_V2~2

None

Self-configuration Ipsec

Enumeration Type

MAIN(Main Mode), MAIN~2, AGGRESSIVE(Agg AGGRESSIVE~4 ressive Mode)

None

Self-configuration Ipsec

Password Type

0~127 characters

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, PERIODIC(Periodic PERIODIC~2 )

None

Self-configuration Ipsec

Interval Type

10~3600

N/A

Self-configuration Ipsec

Interval Type

3~30

N/A

Self-configuration Ipsec

Interval Type

3~10

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), PFS_GROUP1(768bit Diffie-Hellman DISABLE~0, Group), PFS_GROUP1~1, PFS_GROUP2(102 PFS_GROUP2~2 4-bit Diffie-Hellman Group)

None

Self-configuration Ipsec

Enumeration Type

GLOBAL(Global Configuration), LOCAL(Local Configuration)

GLOBAL~0, LOCAL~1

None

Self-configuration Ipsec

Interval Type

30~604800

N/A

Self-configuration Ipsec

Interval Type

0,1843200~429496 N/A 7295

KB

Self-configuration Ipsec

Interval Type

0~3

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration Reliability IP Address Type SCTP Multi-homing

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

Character String Type

0~20 characters

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

Release_R8(Releas e 8), Release_R8~0, Release_R9(Releas Release_R9~1, e 9), Release_R10~2 Release_R10(Relea se 10)

None

Self-configuration

Interval Type

0~15

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

Character String Type

0~20 characters

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Enumeration Type

Release_R8(Releas e 8), Release_R8~0, Release_R9(Releas Release_R9~1, e 9), Release_R10~2 Release_R10(Relea se 10)

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

Interval Type

10~59999

N/A

ms

Self-configuration

Interval Type

11~60000

N/A

ms

Self-configuration

Interval Type

10~59999

N/A

ms

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

2~254

N/A

None

Self-configuration

Interval Type

1~253

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

ALDER32(ALDER3 ALDER32~0, 2), CRC32(CRC32) CRC32~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

1~254

N/A

None

Self-configuration

Interval Type

10~500

N/A

ms

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration Reliability IP Address Type SCTP Multi-homing

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

2~254

N/A

None

Self-configuration

Interval Type

1~253

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

ALDER32(ALDER3 ALDER32~0, 2), CRC32(CRC32) CRC32~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

1~254

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Interval Type

0~127

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

Character String Type

0~20 characters

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack Self-configuration IPsec for IPv6

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration IPsec for IPv6

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration IPsec for IPv6

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration IPsec for IPv6

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration IPsec for IPv6

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration

Character String Type

0~20 characters

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration Ipsec

Character String Type

0~15 characters

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

Interval Type

10~59999

N/A

ms

Self-configuration

Interval Type

11~60000

N/A

ms

Self-configuration

Interval Type

10~59999

N/A

ms

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

2~254

N/A

None

Self-configuration

Interval Type

1~253

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

ALDER32(ALDER3 ALDER32~0, 2), CRC32(CRC32) CRC32~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

1~254

N/A

None

Self-configuration

Interval Type

10~500

N/A

ms

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Interval Type

16~79

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration Ipsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Character String Type

0~0,3~3 characters N/A

None

Self-configuration

Character String Type

0~0,2~3 characters N/A

None

Self-configuration

Interval Type

0~1048575

N/A

None

Self-configuration

Character String Type

0~20 characters

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Enumeration Type

Release_R8(Releas e 8), Release_R8~0, Release_R9(Releas Release_R9~1, e 9), Release_R10~2 Release_R10(Relea se 10)

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration IPsec for IPv6

Character String Type

0~15 characters

N/A

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

Interval Type

0~1

N/A

None

Self-configuration

Interval Type

0~7

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration Reliability IP Address Type SCTP Multi-homing

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration IPsec

Character String Type

0~15 characters

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1~99

N/A

None

Self-configuration

Interval Type

1000~60000

N/A

ms

Self-configuration

Interval Type

2~254

N/A

None

Self-configuration

Interval Type

1~253

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Enumeration Type

ALDER32(ALDER3 ALDER32~0, 2), CRC32(CRC32) CRC32~1

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration

Interval Type

1~254

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

Self-configuration

Character String Type

1~15 characters

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration Reliability IP Address Type SCTP Multi-homing

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Interval Type

1024~65535

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Self-configuration IPsec

IP Address Type

Valid IP address

N/A

None

Self-configuration

Character String Type

0~0,3~3 characters N/A

None

Self-configuration

Character String Type

0~0,2~3 characters N/A

None

IPv4/IPv6 Dual Stack Self-configuration

Interval Type

0~1048575

N/A

None

Self-configuration

Character String Type

0~20 characters

N/A

None

Self-configuration

Interval Type

0~3

N/A

None

IPv4/IPv6 Dual Stack Self-configuration

Enumeration Type

Release_R8(Releas e 8), Release_R8~0, Release_R9(Releas Release_R9~1, e 9), Release_R10~2 Release_R10(Relea se 10)

None

Public Key Infrastructure(PKI)

Character String Type

1~127 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

1~128 characters

N/A

None

None

Enumeration Type

SHA1(SHA1), SHA256(SHA256)

SHA1~0, SHA256~2

None

Public Key Infrastructure(PKI)

Enumeration Type

ESN(ESN), MAC(MAC), IP(IP)

ESN~0, MAC~1, IP~2

None

Public Key Infrastructure(PKI)

Character String Type

0~32 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~0,2~2 characters N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~64 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~64 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Bit Field Type

DATA_ENCIPHER MENT(DATA_ENCI PHERMENT), DIGITAL_SIGNATU RE(DIGITAL_SIGN ATURE), KEY_AGREEMENT (KEY_AGREEMEN T), KEY_ENCIPHERM ENT(KEY_ENCIPH ERMENT)

DATA_ENCIPHER MENT~0, DIGITAL_SIGNATU RE~1, None KEY_AGREEMENT ~2, KEY_ENCIPHERM ENT~3

Public Key Infrastructure(PKI)

Enumeration Type

SHA1(SHA1), MD5(MD5), SHA256(SHA256)

SHA1~0, MD5~1, SHA256~2

None

Public Key Infrastructure(PKI)

Enumeration Type

KEYSIZE1024(KEY SIZE1024), KEYSIZE1024~0, KEYSIZE2048(KEY KEYSIZE2048~1 SIZE2048)

None

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

IP Address Type

Valid IP address

N/A

None

Public Key Infrastructure(PKI)

Character String Type

1~64 characters

N/A

None

Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI)

Character String Type Character String Type Character String Type Character String Type Character String Type

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

IKE(IKE), SSL(SSL) IKE~0, SSL~1

None

Public Key Infrastructure(PKI)

Character String Type

1~64 characters

N/A

None

Public Key Infrastructure(PKI) Public Key Infrastructure(PKI)

Character String Type Character String Type

0~128 characters

N/A

None

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~15 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

NORMALLY(NORM ALLY), NORMALLY~0, ABNORMALITY(AB ABNORMALITY~1, None NORMALITY), FILENOTEXIST~2 FILENOTEXIST(Fil e not exist)

Public Key Infrastructure(PKI)

Enumeration Type

IKE(IKE), SSL(SSL) IKE~0, SSL~1

None

Public Key Infrastructure(PKI)

Character String Type

1~64 characters

N/A

None

Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI)

Character String Type Character String Type Character String Type Character String Type

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

NORMALLY(NORM ALLY), NORMALLY~0, ABNORMALITY(AB ABNORMALITY~1, None NORMALITY), FILENOTEXIST~2 FILENOTEXIST(Fil e not exist)

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

1~64 characters

N/A

None

Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI)

Character String Type Character String Type Character String Type Character String Type

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

NORMALLY(NORM ALLY), NORMALLY~0, ABNORMALITY(AB ABNORMALITY~1, None NORMALITY), FILENOTEXIST~2 FILENOTEXIST(Fil e not exist)

Public Key Infrastructure(PKI)

Character String Type

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

Character String Type

1~64 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

NORMAL(Normal), CERTLOSS(Certific ate Loss), CERTDAMAGE(Ce rtificate Damage), UNKNOWFORMAT (Unknow File Format), FAILED(Other failed Reason) 0~128 characters 0~128 characters

NORMAL~0, CERTLOSS~1, CERTDAMAGE~2, None UNKNOWFORMAT ~3, FAILED~4

Public Key Infrastructure(PKI) Public Key Infrastructure(PKI) Public Key Infrastructure(PKI)

Character String Type Character String Type Character String Type

N/A N/A

None None

0~128 characters

N/A

None

Public Key Infrastructure(PKI)

IP Address Type

Valid IP address

N/A

None

Public Key Infrastructure(PKI)

Character String Type

0~255 characters

N/A

None

Public Key Infrastructure(PKI)

Password Type

0~255 characters

N/A

None

Public Key Infrastructure(PKI)

Interval Type

0~65535

N/A

None

Public Key Infrastructure(PKI)

Character String Type

1~64 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Public Key Infrastructure(PKI)

Interval Type

8~240

N/A

Public Key Infrastructure(PKI)

Interval Type

0~3

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

FTP(FTP), LDAP(LDAP)

FTP~0, LDAP~1

None

Public Key Infrastructure(PKI)

Character String Type

0~255 characters

N/A

None

Public Key Infrastructure(PKI)

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Public Key Infrastructure(PKI)

Interval Type

1~15

N/A

day

Public Key Infrastructure(PKI)

Interval Type

7~180

N/A

day

Public Key Infrastructure(PKI)

Enumeration Type

PROXY(PROXY), CMP(CMP)

PROXY~0, CMP~1 None

Public Key Infrastructure(PKI)

Enumeration Type

NOVERIFY(No Verifying), ALARM(Send an NOVERIFY~0, Alarm If Verifying ALARM~1, CRL Failed), DISCONNECT~2 DISCONNECT(Disc onnect If Verifying CRL Failed)

None

IPsec Access Control List Interval Type (ACL)

3000~4999

N/A

None

IPsec Character String Access Control List Type (ACL)

0~127 characters

N/A

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL) IPv4/IPv6 Dual Stack Character String Access Control List Type (ACL) IPsec Access Control List Interval Type (ACL) IPsec Access Control List Interval Type (ACL)

3000~3999

N/A

None

0~127 characters

N/A

None

3000~4999

N/A

None

1~65535

N/A

None

IPsec Access Control List Enumeration Type (ACL)

DENY(Deny), PERMIT(Permit)

DENY~0, PERMIT~1

None

IPsec Access Control List Enumeration Type (ACL)

IP(IP), ICMP(ICMP), TCP(TCP), UDP(UDP), SCTP(SCTP)

IP~0, ICMP~1, TCP~6, UDP~17, SCTP~132

None

IPsec Access Control List IP Address Type (ACL)

Valid IP address

N/A

None

IPsec Wildcard Mask Access Control List Type (ACL)

Valid wildcard of the N/A IP address

None

IPsec Access Control List Enumeration Type (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

IPsec Access Control List Enumeration Type (ACL)

OP_LT(Less or Equal), OP_GT(Greater or Equal), OP_EQ(Equivalent) , OP_NEQ(Not Equivalent), OP_RANGE(Range )

OP_LT~1, OP_GT~2, OP_EQ~3, OP_NEQ~4, OP_RANGE~5

None

IPsec Access Control List Interval Type (ACL)

0~65535

N/A

None

IPsec Access Control List Interval Type (ACL)

0~65535

N/A

None

IPsec Access Control List IP Address Type (ACL)

Valid IP address

N/A

None

IPsec Wildcard Mask Access Control List Type (ACL)

Valid wildcard of the N/A IP address

None

IPsec Access Control List Enumeration Type (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

IPsec Access Control List Enumeration Type (ACL)

OP_LT(Less or Equal), OP_GT(Greater or Equal), OP_EQ(Equivalent) , OP_NEQ(Not Equivalent), OP_RANGE(Range )

OP_LT~1, OP_GT~2, OP_EQ~3, OP_NEQ~4, OP_RANGE~5

None

IPsec Access Control List Interval Type (ACL)

0~65535

N/A

None

IPsec Access Control List Interval Type (ACL)

0~65535

N/A

None

IPsec Access Control List Enumeration Type (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

IPsec Access Control List Interval Type (ACL)

0~63

N/A

None

IPsec Access Control List Enumeration Type (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

IPsec Access Control List Enumeration Type (ACL)

OP_EQ(Equivalent) , OP_EQ~0, OP_RANGE(Range OP_RANGE~1 )

None

IPsec Access Control List Interval Type (ACL)

1~4094

N/A

None

IPsec Access Control List Interval Type (ACL)

1~4094

N/A

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL) IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

3000~3999

N/A

None

1~65535

N/A

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL)

DENY(Deny), PERMIT(Permit)

DENY~0, PERMIT~1

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL) IPv4/IPv6 Dual Stack IP Address Type Access Control List (ACL)

IP6(IPv6), TCP(TCP), UDP(UDP), ICMP6(ICMP6), SCTP(SCTP) Valid IP address

IP6~0, TCP~6, UDP~17, ICMP6~58, SCTP~132

None

N/A

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

0~128

N/A

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL)

OP_LT(Less or Equal), OP_GT(Greater or Equal), OP_EQ(Equivalent) , OP_NEQ(Not Equivalent), OP_RANGE(Range )

OP_LT~1, OP_GT~2, OP_EQ~3, OP_NEQ~4, OP_RANGE~5

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

0~65535

N/A

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

0~65535

N/A

None

IPv4/IPv6 Dual Stack IP Address Type Access Control List (ACL)

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

0~128

N/A

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL)

OP_LT(Less or Equal), OP_GT(Greater or Equal), OP_EQ(Equivalent) , OP_NEQ(Not Equivalent), OP_RANGE(Range )

OP_LT~1, OP_GT~2, OP_EQ~3, OP_NEQ~4, OP_RANGE~5

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

0~65535

N/A

None

IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

0~65535

N/A

None

IPv4/IPv6 Dual Stack Enumeration Type Access Control List (ACL) IPv4/IPv6 Dual Stack Interval Type Access Control List (ACL)

NO(No), YES(Yes)

NO~0, YES~1

None

0~63

N/A

None

Bidirectional Forwarding Detection

Interval Type

0~7

N/A

None

Bidirectional Forwarding Detection

Interval Type

0~1

N/A

None

Bidirectional Forwarding Detection

Interval Type

0~7

N/A

None

Bidirectional Forwarding Detection

Interval Type

0~95

N/A

None

Bidirectional Forwarding Detection

IP Address Type

Valid IP address

N/A

None

Bidirectional Forwarding Detection

IP Address Type

Valid IP address

N/A

None

Bidirectional Forwarding Detection

Enumeration Type

SINGLE_HOP(Singl e Hop), SINGLE_HOP~0, MULTI_HOP(Multipl MULTI_HOP~1 e Hops)

None

Bidirectional Forwarding Detection

Interval Type

10~1000

N/A

ms

Bidirectional Forwarding Detection

Interval Type

10~1000

N/A

ms

Bidirectional Forwarding Detection

Interval Type

3~10

N/A

None

Bidirectional Forwarding Detection

Enumeration Type

MAINTENANCE(M aintenance), MAINTENANCE~0, None RELIABILITY(Relia RELIABILITY~1 bility)

Bidirectional Forwarding Detection

Interval Type

0~63

N/A

None

Bidirectional Forwarding Detection

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

Bidirectional Forwarding Detection Bidirectional Forwarding Detection

Enumeration Type

ADMINDOWN(Adm ADMINDOWN~0, in Down), DOWN~1, INIT~2, DOWN(Down), UP~3 INIT(Init), UP(Up) DEMAND_MODE(D emand Mode), ASYNCHRONOUS _MODE(Asynchron ous Mode)

None

Enumeration Type

DEMAND_MODE~ 1, None ASYNCHRONOUS _MODE~2

Bidirectional Forwarding Detection Bidirectional Forwarding Detection Bidirectional Forwarding Detection

Interval Type

10~1000

N/A

ms

Interval Type

10~1000

N/A

ms

Interval Type

0~4294967295

N/A

ms

Bidirectional Forwarding Detection

Interval Type

0~4294967295

N/A

None

Bidirectional Forwarding Detection Bidirectional Forwarding Detection Bidirectional Forwarding Detection Bidirectional Forwarding Detection

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

None

Bidirectional Forwarding Detection

Enumeration Type

NO_DIAGNOSTIC( No Diagnostic), CTRL_DECT_TIME _EXPIRED(Control Detection Time Expired), ECHO_FUNC_FAIL ED(Echo Function Failed), NEIGHBOR_SIG_S ESSION_DOWN(N eighbor Signaled Session Down), FORDWARDING_P LANE_RESET(For warding Plane Reset), PATH_DOWN(Path Down), CONCATENATED_ PATH_DOWN(Con catenated Path Down), ADMIN_DOWN(Ad ministratively Down), REVERSE_CONCA TENTATED_PATH _DOWN(Reverse Concatenated Path Down), PEER_ADMIN_DO WN(Peer Administratively

NO_DIAGNOSTIC~ 0, CTRL_DECT_TIME _EXPIRED~1, ECHO_FUNC_FAIL ED~2, NEIGHBOR_SIG_S ESSION_DOWN~3, FORDWARDING_P LANE_RESET~4, None PATH_DOWN~5, CONCATENATED_ PATH_DOWN~6, ADMIN_DOWN~7, REVERSE_CONCA TENTATED_PATH _DOWN~8, PEER_ADMIN_DO WN~9

Bidirectional Forwarding Detection

Interval Type

0~15

N/A

None

Bidirectional Forwarding Detection

Enumeration Type

DRAFT4(DRAFT4), DRAFT4~0, STANDARD(STAN STANDARD~1 DARD)

None

Public Key Infrastructure(PKI)

Enumeration Type

DEFAULT(Default), DEFAULT~0, SPECIFIC(Specific) SPECIFIC~1

None

Public Key Infrastructure(PKI)

Interval Type

0~7

N/A

None

Public Key Infrastructure(PKI)

Interval Type

0~1

N/A

None

Public Key Infrastructure(PKI)

Interval Type

0~7

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

1~8191

N/A

None

Ethernet OAM(IEEE IP Address Type 802.1ag)

Valid IP address

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~1

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.1ag)

NO(No), YES(Yes)

NO~0, YES~1

None

Ethernet OAM(IEEE Interval Type 802.1ag)

1~4094

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.1ag)

10ms(10ms), 100ms(100ms), 1s(1s), 10s(10s), 1min(1min), 10min(10min) 0~32

10ms~2, 100ms~3, 1s~4, 10s~5, None 1min~6, 10min~7

Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag)

N/A

None

0~64

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295 0~4294967295

N/A N/A

None None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

None

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

1~8191

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~1

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.1ag)

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

Ethernet OAM(IEEE Enumeration Type 802.1ag)

ETH(Ethernet Port), ETHTRK(Ethernet ETH~3, ETHTRK~4 None Trunk)

Ethernet OAM(IEEE Interval Type 802.1ag)

0~5

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.1ag)

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Ethernet OAM(IEEE Enumeration Type 802.1ag)

NO(No), YES(Yes)

NO~0, YES~1

None

Ethernet OAM(IEEE Interval Type 802.1ag)

1~4094

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~7

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag) Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

0~4294967295

N/A

None

0~4294967295

N/A

None

0~4294967295

N/A

None

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Character String 802.1ag) Type

1~43 characters

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

1~8191

N/A

None

Ethernet OAM(IEEE Compound Type 802.1ag)

14 characters

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.1ag) Ethernet OAM(IEEE Compound Type 802.1ag)

NORMAL(Normal), NORMAL~1, FAULT(Fault) FAULT~2 14 characters N/A

None

None

Ethernet OAM(IEEE Enumeration Type 802.1ag)

NO(No), YES(Yes)

NO~0, YES~1

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.1ag)

0~4

N/A

None

Ethernet OAM(IEEE IP Address Type 802.1ag)

Valid IP address

N/A

None

Integrated Firewall

Enumeration Type

TCP(TCP Protocol), TCP~6, UDP~17 UDP(UDP Protocol)

None

Integrated Firewall

Enumeration Type

22(22), 23(23), 67(67), 68(68), 80(80), 319(319), 320(320), 443(443), 500(500), 1110(1110), 1120(1120), 2700(2700), 3784(3784), 4443(4443), 4500(4500), 4784(4784), 6000(6000), 6001(6001), 6006(6006), 6007(6007), 17185(17185), 30023(30023), 33003(33003), 45300(45300)

22~22, 23~23, 67~67, 68~68, 80~80, 319~319, 320~320, 443~443, 500~500, 1110~1110, 1120~1120, 2700~2700, 3784~3784, 4443~4443, None 4500~4500, 4784~4784, 6000~6000, 6001~6001, 6006~6006, 6007~6007, 17185~17185, 30023~30023, 33003~33003, 45300~45300

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None ETH_COVERBOAR D~5

None

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), LOOPINT(Loopbac k Interface)

PPP~0, MPGRP~2, ETH~3, None ETHTRK~4, LOOPINT~6

None

Interval Type

0~15

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Subnet Mask Type

Valid Mask address N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~65535

N/A

None

IPv4/IPv6 Dual Stack

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~128

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

IP6_DAD_OK(Valid ), IP6_DAD_TENTATI VE(Tentative), IP6_DAD_DUPLIC ATED(Duplicate), IP6_DAD_UNKNO W(Unknown)

IP6_DAD_OK~1, IP6_DAD_TENTATI VE~2, IP6_DAD_DUPLIC None ATED~4, IP6_DAD_UNKNO W~8

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Chain Topology Tree Topology Self-configuration

IP Address Type

Valid IP address

N/A

None

Self-configuration

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

DiffServ QoS Support

Enumeration Type

IPPRECEDENCE(I IPPRECEDENCE~ P Precedence), None 0, DSCP~1 DSCP(DSCP)

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

DiffServ QoS Support

Interval Type

0~100

N/A

DiffServ QoS Support

Interval Type

0~1000

N/A

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

Access Control based on 802.1x

Interval Type

0~5

N/A

None

Access Control based on 802.1x

Enumeration Type

EAP-TLS(EAP-TLS EAP-TLS~13 authentic method)

None

Access Control based on 802.1x

Interval Type

0~4294967295

N/A

None

Access Control based on 802.1x

Interval Type

0~4294967295

N/A

None

Access Control based on 802.1x

Enumeration Type

NULL(NULL), LIC_OFF(License Off), NOTIFY_FAIL(Notifi cation Authentication Failed), NO_CERT(Certifica te Not Exist), PORT_DOWN(Tran sport Not Activated)

NULL~0, LIC_OFF~1, NOTIFY_FAIL~2, NO_CERT~3, PORT_DOWN~6

None

Access Control based on 802.1x

Interval Type

0~4294967295

N/A

None

Access Control based on 802.1x

Enumeration Type

UNAUTHENTICAT ED(Unauthenticated ), AUTHENTICATING (Authenticating), AUTHENTIC_SUC CEED(Authenticate Succeed), AUTHENTIC_FAIL( Authenticate Fail), DHCP_AUTHENTI CATING(DHCP Activation Authenticating)

UNAUTHENTICAT ED~0, AUTHENTICATING ~1, AUTHENTIC_SUC None CEED~2, AUTHENTIC_FAIL~ 3, DHCP_AUTHENTI CATING~4

Access Control based on 802.1x

Interval Type

0~4294967295

N/A

None

Access Control based on 802.1x

Interval Type

0~4294967295

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

VLAN Support (IEEE 802.1p/q)

Interval Type

0~7

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~7,255

N/A

None

None

Enumeration Type

ALLPORT(All Ports), ALLPORT~0, SINGLEPORT(Sing SINGLEPORT~1 le Port)

None

None

Enumeration Type

E1_UNBA(E1 Unbalance), E1_BA(E1 Balance), T1(T1)

E1_UNBA~0, E1_BA~1, T1~2

None

None

Enumeration Type

E1_DOUBLE_FRA ME(E1 Double Frames), E1_CRC4_MULTI_ FRAME(E1 CRC4 Multiple Frames), T1_SUPER_FRAM E(T1 Super Frames), T1_EXTENDED_S UPER_FRAME(T1 Extended Super Frames)

E1_DOUBLE_FRA ME~0, E1_CRC4_MULTI_ FRAME~1, None T1_SUPER_FRAM E~2, T1_EXTENDED_S UPER_FRAME~3

None

Enumeration Type

HDB3(E1 HDB3 Code), AMI(E1/T1 AMI Code), B8ZS(T1 B8ZS Code)

HDB3~0, AMI~1, B8ZS~2

None

None

Enumeration Type

MASTER(Master Mode), SLAVE(Slave Mode)

MASTER~0, SLAVE~1

None

None

Enumeration Type

OK(Available), LOCAL_LOOP(Loc al Loop), REMOTE_LOOP(R emote Loop), PAYLOAD_LOOP( Payload Loop), SINGLE_CH_LOO P(Single Channel Loop), LOS(Loss of Signal), AIS(Alarm Indication Signal), LFA(Loss of Frame Alignment), RA(Remote Alarm Indication), LMFA(Loss of Multiframe Alignment), SLIP(Slip), OTHERS(Other Fault), BACKUP(Backup), PHYSICAL_LOOP( Physical Loop) EXECUTELINKTES TFlAG_0(No Test), EXECUTELINKTES TFlAG_1(Offline Test), EXECUTELINKTES TFlAG_2(Online Test) NO(No), YES(Yes)

OK~0, LOCAL_LOOP~1, REMOTE_LOOP~2 , PAYLOAD_LOOP~ 3, SINGLE_CH_LOO P~4, LOS~5, None AIS~6, LFA~7, RA~8, LMFA~9, SLIP~10, OTHERS~11, BACKUP~12, PHYSICAL_LOOP~ 13

None

Enumeration Type

EXECUTELINKTES TFlAG_0~0, EXECUTELINKTES None TFlAG_1~1, EXECUTELINKTES TFlAG_2~2

None

Enumeration Type

NO~0, YES~1

None

None

Interval Type

0~720

N/A

min

None

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0, e Board), E1_COVERBOARD None E1_COVERBOARD ~3 (E1 Cover Board)

None

Enumeration Type

E1_UNBA(E1 Unbalance), E1_BA(E1 Balance), T1(T1), UNKNOWN(Unkno wn) E1_DOUBLE_FRA ME(E1 Double Frames), E1_CRC4_MULTI_ FRAME(E1 CRC4 Multiple Frames), T1_SUPER_FRAM E(T1 Super Frames), T1_EXTENDED_S UPER_FRAME(T1 Extended Super Frames), E1_MODIFY_CRC4 _MULTIFRAME(Mo dify CRC4 Multiple Frames), UNKNOWN(Unkno wn) HDB3(E1 HDB3 Code), AMI(E1/T1 AMI Code), B8ZS(T1 B8ZS Code), UNKNOWN(Unkno wn) 1E-3(1E-3), 1E4(1E-4), 1E-5(1E5), 1E-6(1E-6)

E1_UNBA~0, E1_BA~1, T1~2, None UNKNOWN~42949 67294

None

Enumeration Type

E1_DOUBLE_FRA ME~0, E1_CRC4_MULTI_ FRAME~1, T1_SUPER_FRAM E~2, None T1_EXTENDED_S UPER_FRAME~3, E1_MODIFY_CRC4 _MULTIFRAME~4, UNKNOWN~42949 67294

None

Enumeration Type

HDB3~0, AMI~1, B8ZS~2, None UNKNOWN~42949 67294

None

Enumeration Type

1E-3~3, 1E-4~4, 1ENone 5~5, 1E-6~6

Ethernet OAM(IEEE Interval Type 802.3ah)

0~7

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~1

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~7

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.3ah)

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

Ethernet OAM(IEEE Enumeration Type 802.3ah)

ETH(Ethernet Port) ETH~3

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~5

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.3ah)

PASSIVE(Passive Mode), ACTIVE(Active Mode)

PASSIVE~0, ACTIVE~1

None

Ethernet OAM(IEEE Interval Type 802.3ah)

10,20,50,100,200,5 N/A 00,1000

ms

Ethernet OAM(IEEE Interval Type 802.3ah)

64~1518

N/A

byte

Ethernet OAM(IEEE Enumeration Type 802.3ah)

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Ethernet OAM(IEEE Enumeration Type 802.3ah) Ethernet OAM(IEEE Interval Type 802.3ah)

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

1~60

N/A

Ethernet OAM(IEEE Interval Type 802.3ah)

1~65535

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

10~900

N/A

Ethernet OAM(IEEE Interval Type 802.3ah)

1~900

N/A

None

Ethernet OAM(IEEE Enumeration Type 802.3ah)

OAM3AH_SESSIO N_IDLE(Idle Phase), OAM3AH_SESSIO N_DISCOVER(Disc over Phase), OAM3AH_SESSIO N_DETECT(Detect Phase), OAM3AH_SESSIO N_LB_LOCAL(Loop back Response Phase), OAM3AH_SESSIO N_LB_REMOTE(Lo opback Start Phase) 0~4294967295

OAM3AH_SESSIO N_IDLE~0, OAM3AH_SESSIO N_DISCOVER~1, OAM3AH_SESSIO None N_DETECT~2, OAM3AH_SESSIO N_LB_LOCAL~3, OAM3AH_SESSIO N_LB_REMOTE~4

Ethernet OAM(IEEE Interval Type 802.3ah) Ethernet OAM(IEEE Interval Type 802.3ah) Ethernet OAM(IEEE Interval Type 802.3ah) Ethernet OAM(IEEE Interval Type 802.3ah)

N/A

None

0~4294967295

N/A

None

0~4294967295

N/A

None

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

Ethernet OAM(IEEE Interval Type 802.3ah)

0~4294967295

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

None

Interval Type

0~5

N/A

None

None

Enumeration Type

COPPER(Copper), FIBER(Fiber), COPPER~0, None AUTO(Automatic FIBER~1, AUTO~2 Detection)

None

Interval Type

46~1800

N/A

byte

None

Enumeration Type

10M(10M), 100M(100M), 1000M(1000M), AUTO(Automatic Negotiation)

10M~0, 100M~1, None 1000M~2, AUTO~3

None

Enumeration Type

FULL(Full Duplex), AUTO(Automatic Negotiation)

FULL~1, AUTO~2

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Enumeration Type

CLOSE(Close), OPEN(Open)

CLOSE~0, OPEN~1

None

None

Interval Type

0~100

N/A

per mill

None

Interval Type

0~100

N/A

per mill

None

Compound Type

14 characters

N/A

None

None

Enumeration Type

UP(Up), DOWN(Down) NOLOOP(No Loop), REMOTE(Remote Loopback), LOCAL(Local Loopback), UNKNOWN(Unkno wn)

UP~0, DOWN~1

None

None

Enumeration Type

NOLOOP~0, REMOTE~1, LOCAL~2, UNKNOWN~3

None

None

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

byte

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

byte/s

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

byte

None

Interval Type

0~10

N/A

byte/s

None

Interval Type

0~4294967295

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Enumeration Type

FORCE(Force), AUTO(Automatic Negotiation) FORCE(Force), AUTO(Automatic Negotiation) 10M(10M), 100M(100M), 1000M(1000M), AUTO(Automatic Negotiation)

FORCE~0, AUTO~1 FORCE~0, AUTO~1

None

None

Enumeration Type

None

None

Enumeration Type

10M~0, 100M~1, None 1000M~2, AUTO~3

None

Enumeration Type

HALF(Half Duplex), FULL(Full Duplex), HALF~0, FULL~1, AUTO(Automatic AUTO~2 Negotiation)

None

None

Enumeration Type

FORCE(Force), AUTO(Automatic FORCE~0, Negotiation), AUTO~1, UNKNOWN(Unkno UNKNOWN~2 wn)

None

None

Enumeration Type

10M(10M), 100M(100M), 1000M(1000M), 10M~0, 100M~1, AUTO(Automatic 1000M~2, AUTO~3, None Negotiation), UNKNOWN~4 UNKNOWN(Unkno wn) HALF(Half Duplex), FULL(Full Duplex), HALF~0, FULL~1, AUTO(Automatic AUTO~2, Negotiation), UNKNOWN~3 UNKNOWN(Unkno wn)

None

Enumeration Type

None

None

Enumeration Type

UP(Up), DOWN(Down)

UP~0, DOWN~1

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~7

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~1

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~7

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~2

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

DISABLE(Disable LACP), ENABLE(Enable LACP)

DISABLE~0, ENABLE~1

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

46~1800

N/A

byte

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

UP(Up), DOWN(Down)

UP~0, DOWN~1

None

Ethernet Link Aggregation(IEEE 802.3ad)

Compound Type

14 characters

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Compound Type

14 characters

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad) Ethernet Link Aggregation(IEEE 802.3ad) Ethernet Link Aggregation(IEEE 802.3ad) Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~2

N/A

None

Character String Type

0~7 characters

N/A

None

Interval Type

0~2

N/A

None

Character String Type

0~7 characters

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

packet

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

byte

Ethernet Link Aggregation(IEEE 802.3ad) Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

packet

Interval Type

0~4294967295

N/A

byte

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

packet

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

byte

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

packet

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

byte

Ethernet Link Aggregation(IEEE 802.3ad) Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

None

IP Address Type

Valid IP address

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~7

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~1

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~7

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~2

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~5

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~255

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

UP(Up), DOWN(Down)

UP~0, DOWN~1

None

Ethernet Link Aggregation(IEEE 802.3ad)

Compound Type

14 characters

N/A

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

SHORT(Short Timeout), LONG(Long Timeout), NULL(NULL)

SHORT~0, LONG~1, NULL~255

None

Ethernet Link Aggregation(IEEE 802.3ad)

Enumeration Type

SHORT(Short Timeout), LONG(Long Timeout), NULL(NULL)

SHORT~0, LONG~1, NULL~255

None

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

packet

Ethernet Link Aggregation(IEEE 802.3ad)

Interval Type

0~4294967295

N/A

packet

None

Interval Type

10~254

N/A

None

None

Interval Type

0~39

N/A

None

None

Interval Type

0~39

N/A

None

None

Interval Type

0~63

N/A

None

None

Interval Type

0~100

N/A

None

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

None

Interval Type

0~100

N/A

None

Interval Type

0~1000

N/A

Integrated Firewall

Enumeration Type

ARP(ARP), ICMP(ICMP), TCP(TCP), SYN(SYN), UDP(UDP)

ARP~0, ICMP~1, TCP~2, SYN~3, UDP~4

None

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Integrated Firewall

Interval Type

1~4096

N/A

packet/s

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Integrated Firewall

Interval Type

1~4096

N/A

packet/s

Integrated Firewall

Interval Type

0~4294967295

N/A

None

Integrated Firewall

Interval Type

0~4294967295

N/A

None

Transport Overbooking

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Enhanced Transmission QoS Management

Enumeration Type

SINGLE_RATE(Sin gle Rate), SINGLE_RATE~0, DUAL_RATE(Dual DUAL_RATE~1 Rate)

None

Enhanced Transmission QoS Management

Interval Type

0~1200

N/A

IPsec

Character String Type

0~31 characters

N/A

None

IPsec

Interval Type

0,20~28800

N/A

IPsec

Interval Type

0,60~28800

N/A

IPsec

Interval Type

0~63

N/A

None

IPsec

Interval Type

0~7

N/A

None

IPsec

Interval Type

0~1

N/A

None

IPsec

Interval Type

0~7

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Interval Type

1~99

N/A

None

IPsec

Enumeration Type

IKE_V1(IKE V1), IKE_V2(IKE V2)

IKE_V1~1, IKE_V2~2

None

IPsec

Enumeration Type

MAIN(Main Mode), MAIN~2, AGGRESSIVE(Agg AGGRESSIVE~4 ressive Mode)

None

IPsec

Enumeration Type

IP(IP Identify), FQDN(Name Identify)

IP~1, FQDN~2

None

IPsec

IP Address Type

Valid IP address

N/A

None

IPsec

Character String Type

0~31 characters

N/A

None

IPsec

Password Type

0~127 characters

N/A

None

IPsec

Enumeration Type

DISABLE(Disable), DISABLE~0, PERIODIC(Periodic PERIODIC~2 )

None

IPsec

Interval Type

10~3600

N/A

IPsec

Interval Type

3~30

N/A

IPsec

Interval Type

3~10

N/A

None

IPsec

IP Address Type

Valid IP address

N/A

None

IPsec

Interval Type

0~7

N/A

None

IPsec

Interval Type

0~1

N/A

None

IPsec

Interval Type

0~7

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Character String Type

1~15 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

1~99

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

IKE_V1(IKE V1), IKE_V2(IKE V2)

IKE_V1~1, IKE_V2~2

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

MAIN(Main Mode), MAIN~2, AGGRESSIVE(Agg AGGRESSIVE~4 ressive Mode)

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

FQDN(Name Identify), IPV6(IPv6 FQDN~2, IPV6~5 Identify)

None

IPv4/IPv6 Dual Stack IPsec for IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Character String Type

0~31 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Password Type

0~127 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

DISABLE(Disable), DISABLE~0, PERIODIC(Periodic PERIODIC~2 )

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

10~3600

N/A

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

3~30

N/A

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

3~10

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6 IPv4/IPv6 Dual Stack IPsec for IPv6 IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

0~7

N/A

None

Interval Type

0~1

N/A

None

Interval Type

0~7

N/A

None

IPsec

Interval Type

1~99

N/A

None

IPsec

Enumeration Type

DES(DES), 3DES(3DES), AES128(AES128), AES192(AES192), AES256(AES256)

DES~2, 3DES~3, AES128~11, AES192~12, AES256~13

None

IPsec

Enumeration Type

MD5(MD5), SHA1(SHA1), MD5~4, SHA1~5, AES_XCBC_96(AE AES_XCBC_96~6 S_XCBC_96)

None

IPsec

Enumeration Type

PRE_SHARED_KE Y(Pre-shared Key), PRE_SHARED_KE IKE_RSA_SIG(RSA Y~8, None Digital Certificate IKE_RSA_SIG~9 Signature)

IPsec

Enumeration Type

DH_GROUP1(768bit Diffie-Hellman Group), DH_GROUP2(1024bit Diffie-Hellman DH_GROUP1~6, Group), DH_GROUP2~7, None DH_GROUP14(204 DH_GROUP14~14, 8-bit Diffie-Hellman DH_GROUP15~15 Group), DH_GROUP15(307 2-bit Diffie-Hellman Group)

IPsec

Interval Type

60~604800

N/A

IPsec

Enumeration Type

HMAC_MD5(HMAC _MD5), HMAC_MD5~14, HMAC_SHA1(HMA HMAC_SHA1~15, None C_SHA1), AES128_XCBC~18 AES128_XCBC(AE S128_XCBC)

IPsec

Interval Type

0~7

N/A

None

IPsec

Interval Type

0~1

N/A

None

IPsec

Interval Type

0~7

N/A

None

IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission

0~7

N/A

None

IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission

0~1

N/A

None

IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission

0~7

N/A

None

0~15

N/A

None

IP-Based Multimode CoTransmission on BS IP Address Type side(eNodeB) 2G/3G and LTE Cotransmission

Valid IP address

N/A

None

IP-Based Multimode CoTransmission on BS Subnet Mask Type side(eNodeB) 2G/3G and LTE Cotransmission

Valid Mask address N/A

None

IP-Based Multimode CoTransmission on BS Enumeration Type side(eNodeB) 2G/3G and LTE Cotransmission

IP(IP)

IP~1

None

IP-Based Multimode CoTransmission on BS Enumeration Type side(eNodeB) 2G/3G and LTE Cotransmission

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

IP-Based Multimode CoTransmission on BS Enumeration Type side(eNodeB) 2G/3G and LTE Cotransmission

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), TUNNEL(Tunnel)

PPP~0, MPGRP~2, ETH~3, None ETHTRK~4, TUNNEL~8

IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission

0~15

N/A

None

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Integrated Firewall

Interval Type

10~1000

N/A

None

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Integrated Firewall

Interval Type

20~200000

N/A

packet/s

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Integrated Firewall

Interval Type

1~100000

N/A

packet/s

Integrated Firewall

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), LOOPINT(Loopbac k Interface) 0~15 14 characters

PPP~0, MPGRP~2, ETH~3, None ETHTRK~4, LOOPINT~6

Integrated Firewall Integrated Firewall

Interval Type Compound Type

N/A N/A

None None

Integrated Firewall

Compound Type

14 characters

N/A

None

Integrated Firewall

Interval Type

0~4294967295

N/A

None

Integrated Firewall

Enumeration Type

IPV4(IPv4), ARP(ARP), RARP(RARP), IPV6(IPv6), 802_1X(802.1X), LLDP(LLDP), 1588V2(1588V2), CFM(CFM), LACP(LACP), 3AH(3AH)

IPV4~2048, ARP~2054, RARP~2101, IPV6~34525, 802_1X~34958, LLDP~35020, 1588V2~35063, CFM~35074, LACP~8915201, 3AH~8915203

None

Integrated Firewall

IP Address Type

Valid IP address

N/A

None

Integrated Firewall

IP Address Type

Valid IP address

N/A

None

Integrated Firewall

Enumeration Type

ICMP(ICMP), TCP(TCP), UDP(UDP), SCTP(SCTP)

ICMP~1, TCP~6, UDP~17, SCTP~132

None

Integrated Firewall

Interval Type

0~4294967295

N/A

None

Integrated Firewall

Interval Type

0~4294967295

N/A

None

Integrated Firewall

Character String Type

0~200 characters

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~65535

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

NORMAL(Normal), NORMAL~0, VLAN(Vlan) VLAN~1

None

IPv4/IPv6 Dual Stack

Interval Type

0~7

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

0~1

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

6~7

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0 e Board)

None

IPv4/IPv6 Dual Stack

Enumeration Type

ETH(Ethernet Port), TRUNK(Ethernet ETH~3, TRUNK~4, Trunk), None LOOPIF~6 LOOPIF(Loopback Interface)

IPv4/IPv6 Dual Stack

Interval Type

0~5

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~4094

N/A

None

IPv4/IPv6 Dual Stack IPv4/IPv6 Dual Stack IPv4/IPv6 Dual Stack

Interval Type

1280~1800

N/A

byte

Enumeration Type

UP(UP), DOWN(Down) Valid IP address

UP~1, DOWN~2

None

IP Address Type

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

0~8

N/A

None

IPv4/IPv6 Dual Stack

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

0~8

N/A

None

IPv4/IPv6 Dual Stack

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

ms

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

ms

IPv4/IPv6 Dual Stack

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

0~65535

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), TUNNEL(Tunnel)

PPP~0, MPGRP~2, ETH~3, None ETHTRK~4, TUNNEL~8

None

Interval Type

0~15

N/A

None

None

Enumeration Type

QOS(QOS), ANY(ANY)

QOS~0, ANY~1

None

None

Interval Type

0~63

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

0~79

N/A

None

None

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

None

Enumeration Type

S1(S1), X2(X2)

S1~0, X2~1

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

0~4294967294

N/A

Kbit/s

None

Interval Type

0~4294967294

N/A

Kbit/s

None

Interval Type

0~4294967294

N/A

Kbit/s

None

Interval Type

0~4294967294

N/A

Kbit/s

None

Interval Type

0~4294967295

N/A

Kbit/s

None

Interval Type

0~4294967295

N/A

Kbit/s

None

Enumeration Type

NORMAL(Normal), FAULT(Fault), CHECK_DISABLE D(IP Path Check Disabled)

NORMAL~0, FAULT~1, CHECK_DISABLE D~2

None

None

Interval Type

0~15

N/A

None

None

Character String Type

0~47 characters

N/A

None

None

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

0~65535

N/A

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Interval Type

0~15

N/A

None

Interval Type

1~65535

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Enumeration Type

QOS(QOS), ANY(ANY)

QOS~0, ANY~1

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

0~63

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

0~79

N/A

None

None

Enumeration Type

S1(S1), X2(X2)

S1~0, X2~1

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

0~4294967295

N/A

Kbit/s

Interval Type

0~4294967295

N/A

Kbit/s

Interval Type

0~4294967295

N/A

Kbit/s

Interval Type

0~4294967295

N/A

Kbit/s

Interval Type

0~4294967295

N/A

Kbit/s

Interval Type

0~4294967295

N/A

Kbit/s

Enumeration Type

NORMAL(Normal), FAULT(Fault), CHECK_DISABLE D(IP Path Check Disabled) 0~47 characters

NORMAL~0, FAULT~1, CHECK_DISABLE D~2

None

Character String Type

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Enumeration Type

HQ(High Quality), LQ(Low Quality)

HQ~0, LQ~1

None

None

IP Address Type

Valid IP address

N/A

None

IP Performance Monitoring

Interval Type

0~65535

N/A

None

IP Performance Monitoring

IP Address Type

Valid IP address

N/A

None

IP Performance Monitoring

IP Address Type

Valid IP address

N/A

None

IP Performance Monitoring

Interval Type

0~63

N/A

None

IP Performance Monitoring

Enumeration Type

UP(Uplink), BIDIR(Bidirection)

UP~1, BIDIR~2

None

IP Performance Monitoring

Interval Type

0~10000

N/A

ms

IP Performance Monitoring

Interval Type

-10000~10000

N/A

ms

IP Performance Monitoring

Interval Type

-10000~10000

N/A

ms

IP Performance Monitoring

Interval Type

0~1000

N/A

per mill

IP Performance Monitoring

Interval Type

0~1000

N/A

per mill

IP Performance Monitoring

Enumeration Type

IDLE(IDLE), ACTING(ACTING), PMUP(IP PM UP), DEACTING(DEACT ING), UNKNOWN(NULL) IDLE(IDLE), ACTING(ACTING), PMUP(IP PM UP), DEACTING(DEACT ING), UNKNOWN(NULL)

IDLE~0, ACTING~1, PMUP~2, DEACTING~3, UNKNOWN~255 IDLE~0, ACTING~1, PMUP~2, DEACTING~3, UNKNOWN~255

None

IP Performance Monitoring

Enumeration Type

None

IP Performance Monitoring

Enumeration Type

FOUR_TUPLE(FO UR_TUPLE), FOUR_TUPLE~0, THREE_TUPLE(TH THREE_TUPLE~2 REE_TUPLE)

None

IP Performance Monitoring

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

IP Performance Monitoring

Interval Type

0~65535

N/A

None

IP Performance Monitoring IP Performance Monitoring IP Performance Monitoring

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

Interval Type

0~4294967295

N/A

None

Interval Type

0~4294967295

N/A

None

None

Compound Type

None

N/A

None

None

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Compound Type

None

N/A

None

None

Enumeration Type

IPPMVER_V1(Versi on 1.0), IPPMVER_V1~1, IPPMVER_V2(Versi IPPMVER_V2~2 on 2.0)

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

None

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), TUNNEL(Tunnel)

PPP~0, MPGRP~2, None TUNNEL~8

None

Interval Type

0~15

N/A

None

None

Enumeration Type

NEXTHOP(Next Hop), IF(Exit Interface)

NEXTHOP~0, IF~1 None

None

IP Address Type

Valid IP address

N/A

None

None

Subnet Mask Type

Valid Mask address N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

1~255

N/A

None

None

Enumeration Type

STATICHOST(Stati c Host Route), STATICGATEWAY( Static Gateway Route), HOST(Dynamic Host Route), GATEWAY(Dynami c Gateway Route)

STATICHOST~1, STATICGATEWAY None ~2, HOST~3, GATEWAY~4

None

Character String Type

0~47 characters

N/A

None

None

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), LOOPINT(Loopbac k Interface), VI(Virtual Interface), TUNNEL(Tunnel) 0~32

PPP~0, MPGRP~2, ETH~3, ETHTRK~4, None LOOPINT~6, VI~7, TUNNEL~8

None

Interval Type

N/A

None

IPv4/IPv6 Dual Stack

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

0~128

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

NEXTHOP(Next Hop)

NEXTHOP~0

None

IPv4/IPv6 Dual Stack

Enumeration Type

IPADDR6_TYPE_G LOBAL_UNICAST( Global Unicast Address), IPADDR6_TYPE_LI NK_LOCAL(Link Local Address)

IPADDR6_TYPE_G LOBAL_UNICAST~ 0, None IPADDR6_TYPE_LI NK_LOCAL~2

IPv4/IPv6 Dual Stack

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~65535

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~255

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

STATICHOST(Stati c Host Route), STATICGATEWAY( Static Gateway Route), HOST(Dynamic Host Route), GATEWAY(Dynami c Gateway Route)

STATICHOST~1, STATICGATEWAY None ~2, HOST~3, GATEWAY~4

IPv4/IPv6 Dual Stack

Character String Type

0~47 characters

N/A

None

IPsec

Interval Type

0~7

N/A

None

IPsec

Interval Type

0~1

N/A

None

Ipsec

Interval Type

0~7

N/A

None

IPsec

Enumeration Type

BASE_BOARD(Bas e Board), BASE_BOARD~0, ETH_COVERBOAR ETH_COVERBOAR None D(Ethernet Cover D~5 Board)

IPsec

Enumeration Type

ETH(Ethernet Port), ETHTRK(Ethernet ETH~3, ETHTRK~4 None Trunk)

IPsec

Interval Type

0~5

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

1~65535

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Character String Type

1~15 characters

N/A

None

IPsec

Interval Type

0~49

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Interval Type

1~10000

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Interval Type

1~10000

N/A

None

IPsec

Interval Type

0~95

N/A

None

IPsec

Interval Type

0~95

N/A

None

IPsec

Enumeration Type

MASTER(Master IPSec Policy), SLAVE(Slave IPSec Policy)

MASTER~0, SLAVE~1

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Interval Type

1~10000

N/A

None

IPsec

Interval Type

3000~3999

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Enumeration Type

DISABLE(Disable), PFS_GROUP1(768bit Diffie-Hellman DISABLE~0, Group), PFS_GROUP1~1, PFS_GROUP2(102 PFS_GROUP2~2 4-bit Diffie-Hellman Group)

None

IPsec

Enumeration Type

GLOBAL(Global Configuration), LOCAL(Local Configuration)

GLOBAL~0, LOCAL~1

None

IPsec

Interval Type

30~604800

N/A

IPsec

Interval Type

0,1843200~429496 N/A 7295

KB

IPsec

Interval Type

0~7

N/A

None

IPsec

Interval Type

0~1

N/A

None

IPsec

Interval Type

0~7

N/A

None

IPsec

Enumeration Type

WND_DISABLE(0), WND_32(32), WND_64(64), WND_128(128), WND_256(256), WND_512(512), WND_1024(1024), WND_2048(2048), WND_4096(4096)

WND_DISABLE~0, WND_32~1, WND_64~2, WND_128~128, WND_256~256, None WND_512~512, WND_1024~1024, WND_2048~2048, WND_4096~4096

IPv4/IPv6 Dual Stack IPsec for IPv6

Character String Type

1~15 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

1~10000

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

IPV4(IPv4), IPV6(IPv6)

IPV4~4, IPV6~6

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

3000~3999

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

3000~3999

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Character String Type

1~15 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Character String Type

1~15 characters

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

DISABLE(Disable), PFS_GROUP1(768bit Diffie-Hellman DISABLE~0, Group), PFS_GROUP1~1, PFS_GROUP2(102 PFS_GROUP2~2 4-bit Diffie-Hellman Group)

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Enumeration Type

GLOBAL(Global Configuration), LOCAL(Local Configuration)

GLOBAL~0, LOCAL~1

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

30~604800

N/A

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

0,1843200~429496 N/A 7295

KB

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

0~7

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

0~1

N/A

None

IPv4/IPv6 Dual Stack IPsec for IPv6

Interval Type

0~7

N/A

None

IPsec

Character String Type

1~15 characters

N/A

None

IPsec

Enumeration Type

TUNNEL(Tunnel), TUNNEL~0, TRANSPORT(Tran TRANSPORT~1 sport)

None

IPsec

Enumeration Type

AH(AH Protocol), ESP(ESP Protocol), AH~0, ESP~1, AH_ESP(AH/ESP AH_ESP~2 Protocol)

None

IPsec

Enumeration Type

MD5(MD5), SHA1(SHA1), AESMD5~1, SHA1~2, XCBC-MACAES-XCBC-MAC96(AES-XCBC96~5, SHA256~12 MAC-96), SHA256(SHA256)

None

IPsec

Enumeration Type

NULL(NULL), MD5(MD5), SHA1(SHA1), AESXCBC-MAC96(AES-XCBCMAC-96), SHA256(SHA256)

NULL~0, MD5~1, SHA1~2, AESXCBC-MAC-96~5, SHA256~12

None

IPsec

Enumeration Type

NULL(NULL), DES(DES), 3DES(3DES), AES128(AES128), AES192(AES192), AES256(AES256)

NULL~0, DES~1, 3DES~2, AES128~6, AES192~7, AES256~8

None

IPsec

Interval Type

0~7

N/A

None

IPsec

Interval Type

0~1

N/A

None

IPsec

Interval Type

0~7

N/A

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Enumeration Type

UP(Up), DOWN(Down)

UP~0, DOWN~1

None

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

packet

None

Interval Type

0~4294967295

N/A

packet

None

IP Address Type

Valid IP address

N/A

None

None

Subnet Mask Type

Valid Mask address N/A

None

IPv4/IPv6 Dual Stack

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

1~128

N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

IP6_DAD_OK(Valid ), IP6_DAD_TENTATI VE(Tentative), IP6_DAD_DUPLIC ATED(Duplicate), IP6_DAD_UNKNO W(Unknown)

IP6_DAD_OK~1, IP6_DAD_TENTATI VE~2, IP6_DAD_DUPLIC None ATED~4, IP6_DAD_UNKNO W~8

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

IPv4/IPv6 Dual Stack

Interval Type

0~4294967295

N/A

Transport Overbooking Transport Differentiated Flow Control Transport Overbooking Transport Differentiated Flow Control Transport Overbooking Transport Differentiated Flow Control

Interval Type

0~7

N/A

None

Interval Type

0~1

N/A

None

Interval Type

0~7

N/A

None

Transport Overbooking Transport Differentiated Flow Control

Enumeration Type

MPGRP(Multi-link PPP Group), MPGRP~2, ETH~3, ETH(Ethernet Port), ETHTRK~4, None ETHTRK(Ethernet TUNNEL~8 Trunk), TUNNEL(Tunnel)

Transport Overbooking Transport Differentiated Flow Control

Interval Type

0~5

N/A

None

Transport Overbooking Transport Differentiated Flow Control

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Transport Overbooking Transport Differentiated Flow Control

Interval Type

32~1000000

N/A

Kbit/s

Transport Overbooking Transport Differentiated Flow Control

Interval Type

32~1000000

N/A

Kbit

Transport Overbooking Transport Differentiated Flow Control

Interval Type

0~1000000

N/A

Kbit

Transport Overbooking Transport Differentiated Flow Control

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

Transport Overbooking Transport Differentiated Flow Control

Interval Type

32~1000000

N/A

Kbit/s

ML-PPP/MC-PPP

Interval Type

0~7

N/A

None

ML-PPP/MC-PPP

Interval Type

0~1

N/A

None

ML-PPP/MC-PPP

Interval Type

0~7

N/A

None

ML-PPP/MC-PPP

Interval Type

0~3

N/A

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Enumeration Type

NONAUTH(No Authentication), PAP(PAP Authentication), CHAP(CHAP Authentication)

NONAUTH~0, PAP~1, CHAP~2

None

ML-PPP/MC-PPP

Character String Type

1~67 characters

N/A

None

ML-PPP/MC-PPP

Password Type

1~19 characters

N/A

None

ML-PPP/MC-PPP

IP Address Type

Valid IP address

N/A

None

ML-PPP/MC-PPP

Subnet Mask Type

Valid Mask address N/A

None

ML-PPP/MC-PPP

IP Address Type

Valid IP address

N/A

None

ML-PPP/MC-PPP

Enumeration Type

LONG(Long), SHORT(Short)

LONG~0, SHORT~1

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Interval Type

128~1500

N/A

byte

ML-PPP/MC-PPP

Interval Type

1~512

N/A

byte

ML-PPP/MC-PPP

Interval Type

3~1500

N/A

byte

ML-PPP/MC-PPP

Interval Type

1~1000

N/A

ms

ML-PPP/MC-PPP

Interval Type

4,8

N/A

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Interval Type

0~1000

N/A

per mill

ML-PPP/MC-PPP

Interval Type

0~1000

N/A

per mill

ML-PPP/MC-PPP

Enumeration Type

UP(Up), DOWN(Down) INITIAL(INITIAL), STARTING(STARTI NG), CLOSED(CLOSED) , STOPPED(STOPP ED), CLOSING(CLOSIN G), STOPPING(STOPP ING), REQSENT(REQSE NT), ACKRCVD(ACKRC VD), ACKSENT(ACKSE NT), OPENED(OPENED ) INITIAL(INITIAL), STARTING(STARTI NG), CLOSED(CLOSED) , STOPPED(STOPP ED), CLOSING(CLOSIN G), STOPPING(STOPP ING), REQSENT(REQSE NT), ACKRCVD(ACKRC VD), ACKSENT(ACKSE NT), OPENED(OPENED )

UP~1, DOWN~2

None

ML-PPP/MC-PPP

Enumeration Type

INITIAL~1, STARTING~2, CLOSED~3, STOPPED~4, CLOSING~5, STOPPING~6, REQSENT~7, ACKRCVD~8, ACKSENT~9, OPENED~10

None

ML-PPP/MC-PPP

Enumeration Type

INITIAL~1, STARTING~2, CLOSED~3, STOPPED~4, CLOSING~5, STOPPING~6, REQSENT~7, ACKRCVD~8, ACKSENT~9, OPENED~10

None

ML-PPP/MC-PPP

IP Address Type

Valid IP address

N/A

None

ML-PPP/MC-PPP

IP Address Type

Valid IP address

N/A

None

ML-PPP/MC-PPP

IP Address Type

Valid IP address

N/A

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Interval Type

128~1500

N/A

byte

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1 DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Enumeration Type

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1 DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1 0~4294967295 N/A

None

ML-PPP/MC-PPP

Enumeration Type

None

ML-PPP/MC-PPP

Interval Type

packet

ML-PPP/MC-PPP ML-PPP/MC-PPP ML-PPP/MC-PPP

Interval Type Interval Type Interval Type

0~4294967295 0~4294967295 0~4294967295

N/A N/A N/A

packet byte/s byte/s

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

None

ML-PPP/MC-PPP

IP Address Type

Valid IP address

N/A

None

ML-PPP/MC-PPP

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0, e Board), E1_COVERBOARD None E1_COVERBOARD ~3 (E1 Cover Board)

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

byte

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

packet

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

byte

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

packet

ML-PPP/MC-PPP

Interval Type

0~7

N/A

None

ML-PPP/MC-PPP

Interval Type

0~1

N/A

None

ML-PPP/MC-PPP

Interval Type

0~7

N/A

None

ML-PPP/MC-PPP

Interval Type

0~15

N/A

None

ML-PPP/MC-PPP

Interval Type

0~3

N/A

None

ML-PPP/MC-PPP

Interval Type

0~1

N/A

None

ML-PPP/MC-PPP

Interval Type

0~7

N/A

None

ML-PPP/MC-PPP

Interval Type

0~7

N/A

None

ML-PPP/MC-PPP

Bit Field Type

TS1(Time Slot 1), TS2(Time Slot 2), TS3(Time Slot 3), TS4(Time Slot 4), TS5(Time Slot 5), TS6(Time Slot 6), TS7(Time Slot 7), TS8(Time Slot 8), TS9(Time Slot 9), TS10(Time Slot10), TS11(Time Slot11), TS12(Time Slot12), TS13(Time Slot13), TS14(Time Slot14), TS15(Time Slot15), TS16(Time Slot16), TS17(Time Slot17), TS18(Time Slot18), TS19(Time Slot19), TS20(Time Slot20), TS21(Time Slot21), TS22(Time Slot22), TS23(Time Slot23), TS24(Time Slot24), TS25(Time Slot25), TS26(Time Slot26), TS27(Time Slot27), TS28(Time Slot28), TS29(Time Slot29), TS30(Time Slot30), TS31(Time Slot31)

TS1~0, TS2~1, TS3~2, TS4~3, TS5~4, TS6~5, TS7~6, TS8~7, TS9~8, TS10~9, TS11~10, TS12~11, TS13~12, TS14~13, TS15~14, TS16~15, None TS17~16, TS18~17, TS19~18, TS20~19, TS21~20, TS22~21, TS23~22, TS24~23, TS25~24, TS26~25, TS27~26, TS28~27, TS29~28, TS30~29, TS31~30

ML-PPP/MC-PPP

Interval Type

128~1500

N/A

byte

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Interval Type

1~65535

N/A

ms

ML-PPP/MC-PPP

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0, e Board), E1_COVERBOARD None E1_COVERBOARD ~3 (E1 Cover Board)

ML-PPP/MC-PPP

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0, e Board), E1_COVERBOARD None E1_COVERBOARD ~3 (E1 Cover Board)

ML-PPP/MC-PPP

Enumeration Type

UP(Up), DOWN(Down) INITIAL(INITIAL), STARTING(STARTI NG), CLOSED(CLOSED) , STOPPED(STOPP ED), CLOSING(CLOSIN G), STOPPING(STOPP ING), REQSENT(REQSE NT), ACKRCVD(ACKRC VD), ACKSENT(ACKSE NT), OPENED(OPENED )

UP~1, DOWN~2

None

ML-PPP/MC-PPP

Enumeration Type

INITIAL~1, STARTING~2, CLOSED~3, STOPPED~4, CLOSING~5, STOPPING~6, REQSENT~7, ACKRCVD~8, ACKSENT~9, OPENED~10

None

ML-PPP/MC-PPP

Interval Type

128~1500

N/A

byte

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

ML-PPP/MC-PPP

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0, e Board), E1_COVERBOARD None E1_COVERBOARD ~3 (E1 Cover Board)

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

packet

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

byte

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

packet

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

packet

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

byte

ML-PPP/MC-PPP

Interval Type

0~4294967295

N/A

packet

Centralized M2000 Management

Enumeration Type

MASTER(Master), SLAVE(Slave)

MASTER~0, SLAVE~1

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

Interval Type

0~7

N/A

None

Centralized M2000 Management

Interval Type

0~1

N/A

None

Centralized M2000 Management

Interval Type

0~7

N/A

None

Centralized M2000 Management

Enumeration Type

IPV4(IPV4)

IPV4~1

None

Centralized M2000 Management

Enumeration Type

NO(No), YES(Yes)

NO~0, YES~1

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

Enumeration Type

NEXTHOP(Next Hop), IF(Exit Interface)

NEXTHOP~0, IF~1 None

Centralized M2000 Management

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), TUNNEL(Tunnel)

PPP~0, MPGRP~2, None TUNNEL~8

Centralized M2000 Management

Interval Type

0~14

N/A

None

Centralized M2000 Management

Interval Type

1~255

N/A

None

Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

Centralized M2000 Management

Enumeration Type

NORMAL(Normal), ABNORMAL(Abnor NORMAL~0, mal), ABNORMAL~1, UNKNOWN(Unkno UNKNOWN~2 wn)

None

Centralized M2000 Management

Enumeration Type

INUSE(In Use), UNUSED(Unused)

INUSE~0, UNUSED~1

None

Centralized M2000 Management

Enumeration Type

BASE_BOARD(Bas e Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, BACK_BOARD~4, None ETH_COVERBOAR D~5

IPv4/IPv6 Dual Stack Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack Centralized M2000 Management

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack Centralized M2000 Management

Enumeration Type

NORMAL(Normal), ABNORMAL(Abnor NORMAL~0, mal), ABNORMAL~1, UNKNOWN(Unkno UNKNOWN~2 wn)

None

Integrated Firewall

Interval Type

0~7

N/A

None

Integrated Firewall

Interval Type

0~1

N/A

None

Integrated Firewall

Interval Type

0~7

N/A

None

Integrated Firewall

Enumeration Type

ETH(Ethernet Port), ETH~3, ETHTRK(Ethernet ETHTRK~4, Trunk), TUNNEL~8 TUNNEL(Tunnel)

None

Integrated Firewall

Interval Type

0~14

N/A

None

Integrated Firewall

Interval Type

3000~3999

N/A

None

Integrated Firewall

Enumeration Type

PERMIT(Permit), DENY(Deny)

PERMIT~0, DENY~1

None

Integrated Firewall

Enumeration Type

BASE_BOARD(Bas e Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, BACK_BOARD~4, None ETH_COVERBOAR D~5

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

byte

Integrated Firewall

Interval Type

0~4294967295

N/A

packet

Integrated Firewall

Interval Type

4000~4999

N/A

None

Integrated Firewall

Enumeration Type

ADV_ACL(Only Advanced ACL), L2_ACL(Only Layer ADV_ACL~0, 2 ACL), L2_ACL~1, ADV_AND_L2(Adv ADV_AND_L2~2 anced ACL and Layer 2 ACL)

None

Integrated Firewall

IP Address Type

Valid IP address

N/A

None

Integrated Firewall

Subnet Mask Type

Valid Mask address N/A

None

IPv4/IPv6 Dual Stack

Enumeration Type

PASSIVE(Passive Mode), ACTIVE(Active Mode)

PASSIVE~0, ACTIVE~1

None

IPv4/IPv6 Dual Stack

Interval Type

49152~65535

N/A

None

IPv4/IPv6 Dual Stack

Interval Type

500~5000

N/A

ms

IPv4/IPv6 Dual Stack

Interval Type

5~60,65535

N/A

min

IPv4/IPv6 Dual Stack

Interval Type

0~63

N/A

None

Integrated Firewall

Interval Type

0~7

N/A

None

Integrated Firewall

Interval Type

0~1

N/A

None

Integrated Firewall

Interval Type

0~7

N/A

None

Integrated Firewall

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

Integrated Firewall

Enumeration Type

ETH(Ethernet Port), ETH~0, E1T1~1 E1T1(E1/T1 Port)

None

Integrated Firewall

Interval Type

0~7

N/A

None

Integrated Firewall

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

0~7

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

0~1

N/A

None

Interval Type

0~7

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

0~15

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

0~7

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

NONAUTH(No Authentication), PAP(PAP Authentication), CHAP(CHAP Authentication)

NONAUTH~0, PAP~1, CHAP~2

None

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

Character String Type

1~67 characters

N/A

None

Password Type

1~19 characters

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

Bit Field Type

TS1(Time Slot 1), TS2(Time Slot 2), TS3(Time Slot 3), TS4(Time Slot 4), TS5(Time Slot 5), TS6(Time Slot 6), TS7(Time Slot 7), TS8(Time Slot 8), TS9(Time Slot 9), TS10(Time Slot10), TS11(Time Slot11), TS12(Time Slot12), TS13(Time Slot13), TS14(Time Slot14), TS15(Time Slot15), TS16(Time Slot16), TS17(Time Slot17), TS18(Time Slot18), TS19(Time Slot19), TS20(Time Slot20), TS21(Time Slot21), TS22(Time Slot22), TS23(Time Slot23), TS24(Time Slot24), TS25(Time Slot25), TS26(Time Slot26), TS27(Time Slot27), TS28(Time Slot28), TS29(Time Slot29), TS30(Time Slot30), TS31(Time Slot31)

TS1~0, TS2~1, TS3~2, TS4~3, TS5~4, TS6~5, TS7~6, TS8~7, TS9~8, TS10~9, TS11~10, TS12~11, TS13~12, TS14~13, TS15~14, TS16~15, None TS17~16, TS18~17, TS19~18, TS20~19, TS21~20, TS22~21, TS23~22, TS24~23, TS25~24, TS26~25, TS27~26, TS28~27, TS29~28, TS30~29, TS31~30

Compression & Multiplexing over E1/T1 PPP MUX

IP Address Type

Valid IP address

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

Subnet Mask Type

Valid Mask address N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

IP Address Type

Valid IP address

N/A

None

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

1~512

N/A

byte

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

3~1500

N/A

byte

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

1~1000

N/A

ms

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

128~1500

N/A

byte

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

1~65535

N/A

ms

Enumeration Type

UP(Up), DOWN(Down) INITIAL(INITIAL), STARTING(STARTI NG), CLOSED(CLOSED) , STOPPED(STOPP ED), CLOSING(CLOSIN G), STOPPING(STOPP ING), REQSENT(REQSE NT), ACKRCVD(ACKRC VD), ACKSENT(ACKSE NT), OPENED(OPENED ) INITIAL(INITIAL), STARTING(STARTI NG), CLOSED(CLOSED) , STOPPED(STOPP ED), CLOSING(CLOSIN G), STOPPING(STOPP ING), REQSENT(REQSE NT), ACKRCVD(ACKRC VD), ACKSENT(ACKSE NT), OPENED(OPENED )

UP~1, DOWN~2

None

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

INITIAL~1, STARTING~2, CLOSED~3, STOPPED~4, CLOSING~5, STOPPING~6, REQSENT~7, ACKRCVD~8, ACKSENT~9, OPENED~10

None

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

INITIAL~1, STARTING~2, CLOSED~3, STOPPED~4, CLOSING~5, STOPPING~6, REQSENT~7, ACKRCVD~8, ACKSENT~9, OPENED~10

None

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

INITIAL(INITIAL), STARTING(STARTI NG), CLOSED(CLOSED) , STOPPED(STOPP ED), CLOSING(CLOSIN G), STOPPING(STOPP ING), REQSENT(REQSE NT), ACKRCVD(ACKRC VD), ACKSENT(ACKSE NT), OPENED(OPENED )

INITIAL~1, STARTING~2, CLOSED~3, STOPPED~4, CLOSING~5, STOPPING~6, REQSENT~7, ACKRCVD~8, ACKSENT~9, OPENED~10

None

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

IP Address Type

Valid IP address

N/A

None

IP Address Type

Valid IP address

N/A

None

IP Address Type

Valid IP address

N/A

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Interval Type

128~1500

N/A

byte

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Interval Type

0~4294967295

N/A

packet

Interval Type

0~4294967295

N/A

packet

Interval Type

0~4294967295

N/A

byte/s

Interval Type

0~4294967295

N/A

byte/s

Interval Type

0~4294967295

N/A

None

IP Address Type

Valid IP address

N/A

None

Interval Type

1~1000

N/A

per mill

Interval Type

1~1000

N/A

per mill

Compression & Multiplexing over E1/T1 PPP MUX

Enumeration Type

BASE_BOARD(Bas BASE_BOARD~0, e Board), E1_COVERBOARD None E1_COVERBOARD ~3 (E1 Cover Board)

Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX Compression & Multiplexing over E1/T1 PPP MUX

Interval Type

0~4294967295

N/A

byte

Interval Type

0~4294967295

N/A

packet

Interval Type

0~4294967295

N/A

byte

Interval Type

0~4294967295

N/A

packet

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

DiffServ QoS Support

Interval Type

0~63

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~7

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~1

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~7

N/A

None

Enhanced Transmission QoS Management

Enumeration Type

IP(IP)

IP~1

None

Enhanced Transmission QoS Management

Enumeration Type

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

Enhanced Transmission QoS Management

Enumeration Type

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), TUNNEL(Tunnel)

PPP~6, MPGRP~8, ETH~9, None ETHTRK~10, TUNNEL~15

Enhanced Transmission QoS Management

Interval Type

0~15

N/A

None

Enhanced Transmission QoS Management

Enumeration Type

0~0, 1~1, 2~2, 3~3, 4~4, 5~5, 6~6, 7~7, 0, 1, 2, 3, 4, 5, 6, 7, 8~8, 9~9, 10~10, 8, 9, 10, 11, 12, 13, 11~11, 12~12, 14, 15, None 13~13, 14~14, DEFAULTPORT(De 15~15, fault Port) DEFAULTPORT~1 27

Enhanced Transmission QoS Management

Enumeration Type

KBPS(Kbit/s)

KBPS~0

None

Enhanced Transmission QoS Management

Interval Type

32~1000000

N/A

None

Enhanced Transmission QoS Management

Interval Type

32~1000000

N/A

None

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

Kbit

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

Kbit

Enhanced Transmission QoS Management

Interval Type

0~3

N/A

None

Enhanced Transmission QoS Management

Interval Type

1~100

N/A

None

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

None

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

None

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

None

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

None

Enhanced Transmission QoS Management

Interval Type

64~1000000

N/A

Kbit

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management Enhanced Transmission QoS Management Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enumeration Type

SINGLE_RATE(Sin gle Rate), SINGLE_RATE~0, DUAL_RATE(Dual DUAL_RATE~1 Rate)

None

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

None

Enhanced Transmission QoS Management

Interval Type

0~4294967295

N/A

byte/s

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~7

N/A

None

0~1

N/A

None

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~7

N/A

None

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

BASE_BOARD(Bas e Board), E1_COVERBOARD (E1 Cover Board), BACK_BOARD(Bac k Board), ETH_COVERBOAR D(Ethernet Cover Board)

BASE_BOARD~0, E1_COVERBOARD ~3, None BACK_BOARD~4, ETH_COVERBOAR D~5

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

PPP(PPP Link), MPGRP(Multi-link PPP Group), ETH(Ethernet Port), ETHTRK(Ethernet Trunk), TUNNEL(Tunnel)

PPP~6, MPGRP~8, ETH~9, None ETHTRK~10, TUNNEL~15

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~15

N/A

None

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

0~0, 1~1, 2~2, 3~3, 4~4, 5~5, 6~6, 7~7, 0, 1, 2, 3, 4, 5, 6, 7, 8~8, 9~9, 10~10, 8, 9, 10, 11, 12, 13, 11~11, 12~12, 14, 15, None 13~13, 14~14, DEFAULTPORT(De 15~15, fault Port) DEFAULTPORT~1 27

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~1000

N/A

per mill

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~10000

N/A

ms

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

64~1000000

N/A

Kbit/s

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

64~1000000

N/A

Kbit/s

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Transport Overbooking Transport Differentiated Flow Enumeration Type Control Transport Resource Overload Control

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~6

N/A

None

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~500

N/A

ms

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~500

N/A

ms

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~1000000

N/A

Kbit/s

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~1000000

N/A

Kbit/s

Transport Overbooking Transport Differentiated Flow Interval Type Control Transport Resource Overload Control

0~8192

N/A

packet

None

Interval Type

0~79

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

0~1

N/A

None

None

Interval Type

0~7

N/A

None

None

Interval Type

1~34

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

1024~65535

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

IP Address Type

Valid IP address

N/A

None

None

Interval Type

1024~65535

N/A

None

None

Interval Type

10~59999

N/A

ms

None

Interval Type

11~60000

N/A

ms

None

Interval Type

10~59999

N/A

ms

None

Interval Type

1~99

N/A

None

None

Interval Type

1~99

N/A

None

None

Interval Type

1000~60000

N/A

ms

None

Interval Type

2~254

N/A

None

None

Interval Type

1~253

N/A

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Enumeration Type

ALDER32(ALDER3 ALDER32~0, 2), CRC32(CRC32) CRC32~1

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

1~254

N/A

None

None

Enumeration Type

SCTP_STAT_DOW N(Down), SCTP_STAT_CON GESTION(Congesti on), SCTP_STAT_UP(U p) SCTP_TRANSFER _CAUSE_START(S tart), SCTP_TRANSFER _CAUSE_LINKDO WN(Link Down), SCTP_TRANSFER _CAUSE_PORTDI SABLED(Port Disabled), SCTP_TRANSFER _CAUSE_INIT(Initia l), SCTP_TRANSFER _CAUSE_UNKNO WERROR(Unknow n Error), SCTP_TRANSFER _CAUSE_NORMAL (Normal), SCTP_TRANSFER _CAUSE_USERDE LETE(User Delete)

SCTP_STAT_DOW N~0, SCTP_STAT_CON None GESTION~1, SCTP_STAT_UP~2

None

Enumeration Type

SCTP_TRANSFER _CAUSE_START~ 0, SCTP_TRANSFER _CAUSE_LINKDO WN~1, SCTP_TRANSFER _CAUSE_PORTDI SABLED~2, SCTP_TRANSFER None _CAUSE_INIT~3, SCTP_TRANSFER _CAUSE_UNKNO WERROR~4, SCTP_TRANSFER _CAUSE_NORMAL ~5, SCTP_TRANSFER _CAUSE_USERDE LETE~6

None

Compound Type

None

N/A

None

None

Interval Type

0~34

N/A

None

None

Interval Type

0~34

N/A

None

None

Enumeration Type

ACTIVE(Active Path), ACTIVE~0, STANDBY(Standby STANDBY~1 Path) UNBLOCK(Unblock UNBLOCK~0, ), BLOCK(Block) BLOCK~1

None

None

Enumeration Type

None

None

Interval Type

10~500

N/A

ms

None

Character String Type

0~47 characters

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

0~79

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1~34

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1024~65535

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

IP Address Type

Valid IP address

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1024~65535

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1000~60000

N/A

ms

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1000~60000

N/A

ms

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1000~60000

N/A

ms

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1~99

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1~99

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1000~60000

N/A

ms

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

2~254

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1~253

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Enumeration Type

ALDER32(ALDER3 ALDER32~0, 2), CRC32(CRC32) CRC32~1

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

1~254

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Enumeration Type

SCTP_STAT_DOW N(Down), SCTP_STAT_CON GESTION(Congesti on), SCTP_STAT_UP(U p) SCTP_TRANSFER _CAUSE_START(S tart), SCTP_TRANSFER _CAUSE_LINKDO WN(Link Down), SCTP_TRANSFER _CAUSE_PORTDI SABLED(Port Disabled), SCTP_TRANSFER _CAUSE_INIT(Initia l), SCTP_TRANSFER _CAUSE_UNKNO WERROR(Unknow n Error), SCTP_TRANSFER _CAUSE_NORMAL (Normal), SCTP_TRANSFER _CAUSE_USERDE LETE(User Delete)

SCTP_STAT_DOW N~0, SCTP_STAT_CON None GESTION~1, SCTP_STAT_UP~2

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Enumeration Type

SCTP_TRANSFER _CAUSE_START~ 0, SCTP_TRANSFER _CAUSE_LINKDO WN~1, SCTP_TRANSFER _CAUSE_PORTDI SABLED~2, SCTP_TRANSFER None _CAUSE_INIT~3, SCTP_TRANSFER _CAUSE_UNKNO WERROR~4, SCTP_TRANSFER _CAUSE_NORMAL ~5, SCTP_TRANSFER _CAUSE_USERDE LETE~6

IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Compound Type

None

N/A

None

IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6 IPv4/IPv6 Dual Stack S1 and X2 over IPv6

Interval Type

0~34

N/A

None

Interval Type

0~34

N/A

None

Enumeration Type

ACTIVE(Active Path), ACTIVE~0, STANDBY(Standby STANDBY~1 Path) UNBLOCK(Unblock UNBLOCK~0, ), BLOCK(Block) BLOCK~1

None

Enumeration Type

None

Character String Type

0~47 characters

N/A

None

VLAN Support (IEEE 802.1p/q)

IP Address Type

Valid IP address

N/A

None

VLAN Support (IEEE 802.1p/q)

Subnet Mask Type

Valid Mask address N/A

None

VLAN Support (IEEE 802.1p/q)

Interval Type

1~4094

N/A

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking Transport Resource Overload Control Different Transport Interval Type Paths based on QoS Grade Intra-LTE Load Balancing

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Interval Type

0~100

N/A

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Overbooking

Enumeration Type

OFF(Off), ON(On)

OFF~0, ON~1

None

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

Intra-LTE Load Balancing

Interval Type

0~100

N/A

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Transport Resource Enumeration Type Overload Control

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Resource Enumeration Type Overload Control

OFF(Off), ON(On)

OFF~0, ON~1

None

Transport Resource Interval Type Overload Control

0~100

N/A

Transport Resource Interval Type Overload Control

0~100

N/A

Transport Resource Interval Type Overload Control

0~100

N/A

None

Transport Resource Interval Type Overload Control

0~100

N/A

Transport Resource Interval Type Overload Control

0~100

N/A

None

Enumeration Type

WHITELIST(Whiteli st), WHITELIST~1, BLACKLIST(Blackli BLACKLIST~2 st)

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

None

Interval Type

0~4294967295

N/A

None

IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission

0~7

N/A

None

0~1

N/A

None

0~7

N/A

None

IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission IP-Based Multimode CoTransmission on BS Interval Type side(eNodeB) 2G/3G and LTE Cotransmission

0~14

N/A

None

0~7

N/A

None

0~1

N/A

None

0~7

N/A

None

0~4294967295

N/A

byte

0~4294967295

N/A

packet

0~4294967295

N/A

byte

0~4294967295

N/A

packet

VLAN Support (IEEE 802.1p/q)

Interval Type

0~3

N/A

None

VLAN Support (IEEE 802.1p/q)

Enumeration Type

USERDATA(User Data), SIG(Signaling Data), OTHER(Other Data), OM_HIGH(High Level Maintenance Data), OM_LOW(Low Level Maintenance Data)

USERDATA~0, SIG~1, OTHER~3, OM_HIGH~4, OM_LOW~5

None

VLAN Support (IEEE 802.1p/q)

Interval Type

0~63

N/A

None

VLAN Support (IEEE 802.1p/q)

Interval Type

1~4094

N/A

None

VLAN Support (IEEE 802.1p/q)

Interval Type

0~7

N/A

None

VLAN Support (IEEE 802.1p/q)

IP Address Type

Valid IP address

N/A

None

VLAN Support (IEEE 802.1p/q)

Subnet Mask Type

Valid Mask address N/A

None

VLAN Support (IEEE 802.1p/q)

Enumeration Type

SINGLEVLAN(Singl e VLAN), SINGLEVLAN~0, VLANGROUP(VLA VLANGROUP~1 N Group)

None

VLAN Support (IEEE 802.1p/q)

Interval Type

1~4094

N/A

None

VLAN Support (IEEE 802.1p/q)

Interval Type

0~7

N/A

None

VLAN Support (IEEE 802.1p/q)

Interval Type

0~3

N/A

None

VLAN Support (IEEE 802.1p/q)

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

None

Interval Type

5000~60000

N/A

ms

None

Interval Type

3~6

N/A

None

None

Interval Type

0~63

N/A

None

None

Enumeration Type

DISABLE(Disable), DISABLE~0, ENABLE(Enable) ENABLE~1

None

Actual Value Range

Default Value

Recommended Value

Initial Value Setting Source

Impact

0~35

None

None

Equipment Planning BFANT

00

Equipment Planning BFANT

60~254

None

None

Equipment Planning BFANT

00

None

Equipment Planning BFANT

0~128 characters

NULL

None

Equipment Planning BFANT

0~15

None

Equipment Planning BFANT

30,65,90,360

30

None

Default/Recommen BFANT ded Value

33~64

33

None

Default/Recommen BFANT ded Value

INTELLIGENT, DISTRIBUTED

INTELLIGENT

None

N/A

BFANT

SINGLE, DUAL

None

None

N/A

BFANT

0~360

None

None

N/A

BFANT

FOURPORTS, EIGHTPORTS

FOURPORTS(Four None Ports)

N/A

BFANT

0~1, step:0.01

None

None

N/A

BFANT

-180~180

None

None

N/A

BFANT

0~1, step:0.01

None

None

N/A

BFANT

-180~180

None

None

N/A

BFANT

0~1, step:0.01

None

None

N/A

BFANT

-180~180

None

None

N/A

BFANT

0~1, step:0.01

None

None

N/A

BFANT

-180~180

None

None

N/A

BFANT

0~1, step:0.01

None

None

N/A

BFANT

-180~180

None

None

N/A

BFANT

0~1, step:0.01

None

None

N/A

BFANT

-180~180

None

None

N/A

BFANT

0~1048575

None

Radio Planning (Internal planning)

eNodeB

1~64 characters

DBS3900 LTE

None

Radio Planning (Internal planning)

eNodeB

DBS3900_LTE, BTS3900_LTE, BTS3900A_LTE, BTS3900L_LTE, BTS3900AL_LTE

DBS3900_LTE(DB None S3900 LTE)

Equipment Planning eNodeB

ON, OFF

OFF(OFF)

None

Engineering Design eNodeB

22:00:00~5:00:00

00:00:00

None

Engineering Design eNodeB

23:00:00~6:00:00

06:00:00

None

Engineering Design eNodeB

-180~180, step:1e-6 0

None

Radio Planning (Internal planning)

eNodeB

-90~90, step:1e-6

None

Radio Planning (Internal planning)

eNodeB

0~20 characters

None

None

N/A

eNodeB

Default, Normal, Demo, Protected, Emergency

None

None

N/A

eNodeB

Poweroff, Normal

None

None

N/A

eNodeB

0~128 characters

NULL

None

Radio Planning (Internal planning)

eNodeB

DEG, SEC

DEG

None

Equipment Planning eNodeB

0~16 characters

0:0:0

None

Radio Planning (Internal planning)

eNodeB

0~16 characters

0:0:0

None

Radio Planning (Internal planning)

eNodeB

CPRI, TDL_IR

CPRI

None

Equipment Planning eNodeB

Transmission_Pack et_Loss_Rate, Transmission_Dela y, Transmission_Jitter, Packet_Loss_Rate, Cell_RRC_Connect _Succ_Rate, Cell_ERAB_Setup_ Succ_Rate, Cell_Call_Drop_Rat None e, IntraFrequency_HO_Su cc_Rate, InterFrequency_HO_Su cc_Rate, LTECDMA_Handover_ Succ_Rate, LTEWCDMA_Handover _Succ_Rate, LTEGERAN_Handover _Succ_Rate

None

Equipment Planning KPIALARM

ON, OFF

None

OFF

Default/Recommen KPIALARM ded Value

0~4294967295

None

If the KPITYPE parameter is set to Transmission_Pack et_Loss_Rate or Cell_Call_Drop_Rat e, the recommended threshold is 10. If the KPITYPE parameter is set to Transmission_Dela y, the recommended threshold is 300. If the KPITYPE parameter is set to Transmission_Jitter, Default/Recommen KPIALARM the recommended ded Value threshold is 100. If the KPITYPE parameter is set to Packet_Loss_Rate, the recommended threshold is 5. If the KPITYPE parameter is set to Cell_RRC_Connect _Succ_Rate or Cell_ERAB_Setup_ Succ_Rate, the recommended threshold is 90. If the KPITYPE parameter is set to

0~4294967295

None

If the KPITYPE parameter is set to Transmission_Pack et_Loss_Rate or Cell_Call_Drop_Rat e, the recommended threshold is 5. If the KPITYPE parameter is set to Transmission_Dela y, the recommended threshold is 200. If the KPITYPE parameter is set to Transmission_Jitter, Default/Recommen KPIALARM the recommended ded Value threshold is 50. If the KPITYPE parameter is set to Packet_Loss_Rate, the recommended threshold is 1. If the KPITYPE parameter is set to Cell_RRC_Connect _Succ_Rate or Cell_ERAB_Setup_ Succ_Rate, the recommended threshold is 95. If the KPITYPE parameter is set to

0~4294967295

100

If the KPITYPE parameter is set to Transmission_Pack et_Loss_Rate, Transmission_Dela y, Transmission_Jitter, or Packet_Loss_Rate, the recommended value of this parameter is 360. If the KPITYPE parameter is set to Cell_RRC_Connect _Succ_Rate, Default/Recommen Cell_ERAB_Setup_ KPIALARM ded Value Succ_Rate, Cell_Call_Drop_Rat e, IntraFrequency_HO_Su cc_Rate, InterFrequency_HO_Su cc_Rate, LTECDMA_Handover_ Succ_Rate, LTEWCDMA_Handover _Succ_Rate, or LTEGERAN_Handover _Succ_Rate, the recommended value of this parameter is 100.

15minutes, 30minutes, 60minutes, 1day

60minutes(60minut 60minutes es)

Default/Recommen KPIALARM ded Value

0~23

None

Default/Recommen KPIALARM ded Value

1~3

Default/Recommen KPIALARM ded Value

0~17

None

None

Equipment Planning Sector

-180~180, step:1e-6 None

None

Radio Planning (Internal planning)

Sector

-90~90, step:1e-6

None

None

Radio Planning (Internal planning)

Sector

1T1R, 1T2R, 2T2R, None 2T4R, 4T4R, 8T8R

None

Radio Planning (Internal planning)

Sector

NormalMIMO, AIDMIMO

NormalMIMO(Norm None al MIMO)

Radio Planning (Internal planning)

Sector

COMBTYPE_SING LE_RRU, COMBTYPE_TWO _RRU, COMBTYPE_THRE E_RRU, COMBTYPE_FOUR _RRU, COMBTYPE_SING None COMBTYPE_FIVE_ LE_RRU RRU, COMBTYPE_SIX_ RRU, COMBTYPE_SEVE N_RRU, COMBTYPE_EIGH T_RRU

Radio Planning (Internal planning)

Sector

0~62

None

None

Equipment Planning Sector

4~5,60~254

None

None

Equipment Planning Sector

0~8

None

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

None

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

N/A

Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~30 characters

NULL

None

Equipment Planning Sector

-32767~32767

None

None

Radio Planning (Internal planning)

Sector

0~1800000

None

Radio Planning (Internal planning)

Sector

0~1800000

None

Radio Planning (Internal planning)

Sector

0~179

None

Radio Planning (Internal planning)

Sector

0~990

None

Radio Planning (Internal planning)

Sector

0~100

None

Radio Planning (Internal planning)

Sector

DEG, SEC

DEG

None

Radio Planning (Internal planning)

Sector

0~16 characters

0:0:0

None

Radio Planning (Internal planning)

Sector

0~16 characters

0:0:0

None

Radio Planning (Internal planning)

Sector

FALSE, TRUE

FALSE

None

Radio Planning (Internal planning)

Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~62

None

Equipment Planning Sector

4~5,60~254

60

None

Equipment Planning Sector

0~8

None

Equipment Planning Sector

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B

R0A

None

Equipment Planning Sector

0~50, step:0.1

None

None

N/A

Sector

Normal, NoLicense None

None

N/A

Sector

0~40 characters

None

None

N/A

Sector

0~40 characters

None

None

N/A

Sector

COMPATIBLE, HTTPS_ONLY, LOGIN_HTTPS_O NLY

HTTPS_ONLY

None

Equipment Planning

WEBLOGINPOLIC Y

0~35

None

None

Equipment Planning ALD

0~2 characters

None

None

N/A

ALD

0~36 characters

None

None

N/A

ALD

0~49 characters

NULL

None

Equipment Planning ALD

0~62

None

Equipment Planning ALD

4~5,60~254

None

None

Equipment Planning ALD

0~8

None

None

Equipment Planning ALD

AISG1.1, AISG2.0, None 3GPP, UNKNOWN

None

N/A

ALD

0~8

None

None

N/A

ALD

0~2 characters

NULL

None

Equipment Planning ALD

0~36 characters

NULL

None

Equipment Planning ALD

0~19 characters

None

None

N/A

ALD

0~127 characters

None

None

N/A

ALD

0~19 characters

None

None

N/A

ALD

SINGLE_RET, None STMA, MULTI_RET

None

N/A

ALD

R0A, R0B, RET_PORT, R0C, R0D, R0E, R0F, R0G, R0H, NULL

None

None

N/A

ALD

0~62

None

Equipment Planning AntennaPort

4~5,60~254

None

None

Equipment Planning AntennaPort

0~8

None

None

Equipment Planning AntennaPort

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H

None

None

Equipment Planning AntennaPort

0~1000

None

Equipment Planning AntennaPort

0~50

None

Equipment Planning AntennaPort

0~50

None

Equipment Planning AntennaPort

ON, OFF

OFF(OFF)

None

Engineering Design AntennaPort

UER_SELF_DEFIN E, TMA12DB_ONLY_ NON_AISG, UER_SELF_DEFIN TMA24DB_ONLY_ E(UER_SELF_DEF None NON_AISG, INE) RET_ONLY_COAXI AL, TMA12DB_AISG, TMA24DB_AISG

Engineering Design AntennaPort

0~3500

40

None

Engineering Design AntennaPort

0~3500

60

None

Engineering Design AntennaPort

0~3500

185

None

Engineering Design AntennaPort

0~3500

155

None

Engineering Design AntennaPort

0~3500

None

None

N/A

AntennaPort

ON, OFF, NULL

None

None

N/A

AntennaPort

SINGLE_RET, MULTI_RET

None

None

Equipment Planning RET

SINGLE, DUAL

None

None

Equipment Planning RET

REGULAR, DAISY_CHAIN

None

None

Equipment Planning RET

1~8

None

Equipment Planning RET

RET, VRET

None

None

N/A

RET

0~35

None

None

Equipment Planning RET

0~2 characters

None

None

N/A

RET

0~36 characters

None

None

N/A

RET

0~49 characters

NULL

None

Equipment Planning RET

0~62

None

Equipment Planning RET

4~5,60~254

None

None

Equipment Planning RET

0~8

None

None

Equipment Planning RET

AISG1.1, AISG2.0, None 3GPP, UNKNOWN

None

N/A

RET

0~8

None

None

N/A

RET

0~2 characters

NULL

None

Equipment Planning RET

0~36 characters

NULL

None

Equipment Planning RET

0~19 characters

None

None

N/A

RET

0~127 characters

None

None

N/A

RET

0~19 characters

None

None

N/A

RET

SINGLE_RET, None STMA, MULTI_RET

None

N/A

RET

R0A, R0B, RET_PORT, R0C, R0D, R0E, R0F, R0G, R0H, NULL

None

None

N/A

RET

0~35

None

None

Equipment Planning RetDeviceData

1~8

None

None

Equipment Planning RetDeviceData

0~359

None

Radio Planning (Internal planning)

RetDeviceData

0~15 characters

NULL

None

Equipment Planning RetDeviceData

0~32 characters

NULL

None

Equipment Planning RetDeviceData

0~359

None

Default/Recommen RetDeviceData ded Value

0~359

None

Default/Recommen RetDeviceData ded Value

0~359

None

Default/Recommen RetDeviceData ded Value

0~359

None

Default/Recommen RetDeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen RetDeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen RetDeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen RetDeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen RetDeviceData ded Value

0~6 characters

NULL

None

Equipment Planning RetDeviceData

-10~30, step:0.1

None

Radio Planning (Internal planning)

RetDeviceData

0~5 characters

NULL

None

Equipment Planning RetDeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen RetDeviceData ded Value

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen RetDeviceData ded Value

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen RetDeviceData ded Value

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen RetDeviceData ded Value

0~32 characters

NULL

None

Equipment Planning RetDeviceData

0~17 characters

NULL

None

Equipment Planning RetDeviceData

-180~180, step:0.1

None

None

N/A

RetDeviceData

-180~180, step:0.1

None

None

N/A

RetDeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

RetDeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

RetDeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

RetDeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

RetDeviceData

0~359

None

None

N/A

RetDeviceData

0~359

None

None

N/A

RetDeviceData

0~359

None

None

N/A

RetDeviceData

0~359

None

None

N/A

RetDeviceData

0~25.5, step:0.1 0~25.5, step:0.1 0~25.5, step:0.1 0~25.5, step:0.1

None None None None

None None None None

N/A N/A N/A N/A

RetDeviceData RetDeviceData RetDeviceData RetDeviceData

0 None

None

Equipment Planning RetPort

60~254

None

None

Equipment Planning RetPort

0 None

None

Equipment Planning RetPort

RET_PORT

None

None

Equipment Planning RetPort

ON, OFF

OFF(OFF)

None

Equipment Planning RetPort

UER_SELF_DEFIN UER_SELF_DEFIN E, E(UER_SELF_DEF None RET_ONLY_MULTI INE) CORE

Default/Recommen RetPort ded Value

0~3500

40

None

Default/Recommen RetPort ded Value

0~3500

60

None

Default/Recommen RetPort ded Value

0~3500

185

None

Default/Recommen RetPort ded Value

0~3500

155

None

Default/Recommen RetPort ded Value

0~3500

None

None

N/A

RetPort

ON, OFF, NULL

None

None

N/A

RetPort

0~35

None

None

Equipment Planning RETSubunit

1~8

None

None

Equipment Planning RETSubunit

AVAILABLE, UNAVAILABLE, BREAKLINK

None

None

N/A

RETSubunit

-10~30, step:0.1

None

None

N/A

RETSubunit

0~17

None

None

N/A

RETSubunit

0~62,255

255

None

Equipment Planning RETSubunit

4~5,60~255

255

None

Equipment Planning RETSubunit

0~8,255

255

None

Equipment Planning RETSubunit

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H

R0A(R0A)

None

Equipment Planning RETSubunit

0~62,255

255

None

Equipment Planning RETSubunit

4~5,60~255

255

None

Equipment Planning RETSubunit

0~8,255

255

None

Equipment Planning RETSubunit

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H

R0B(R0B)

None

Equipment Planning RETSubunit

-10~30, step:0.1

None

Radio Planning (Internal planning)

RETSubunit

0~1, step:0.1

None

Default/Recommen RETSubunit ded Value

0~49 characters

NULL

None

Engineering Design RETSubunit

1~2

None

None

Equipment Planning TMA

0~35

None

None

Equipment Planning TMA

0~2 characters

None

None

N/A

TMA

0~36 characters

None

None

N/A

TMA

0~49 characters

NULL

None

Equipment Planning TMA

0~62

None

Equipment Planning TMA

4~5,60~254

None

None

Equipment Planning TMA

0~8

None

None

Equipment Planning TMA

AISG1.1, AISG2.0, None 3GPP, UNKNOWN

None

N/A

TMA

0~8

None

None

N/A

TMA

0~2 characters

NULL

None

Equipment Planning TMA

0~36 characters

NULL

None

Equipment Planning TMA

0~19 characters

None

None

N/A

TMA

0~127 characters

None

None

N/A

TMA

0~19 characters

None

None

N/A

TMA

SINGLE_RET, None STMA, MULTI_RET

None

N/A

TMA

R0A, R0B, RET_PORT, R0C, R0D, R0E, R0F, R0G, R0H, NULL

None

None

N/A

TMA

0~35

None

None

Equipment Planning TMADeviceData

1~2

None

None

Equipment Planning TMADeviceData

0~359

None

Default/Recommen TMADeviceData ded Value

0~32 characters

NULL

None

Equipment Planning TMADeviceData

0~359

None

Default/Recommen TMADeviceData ded Value

0~359

None

Default/Recommen TMADeviceData ded Value

0~359

None

Default/Recommen TMADeviceData ded Value

0~359

None

Default/Recommen TMADeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen TMADeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen TMADeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen TMADeviceData ded Value

0~25.5, step:0.1

None

Default/Recommen TMADeviceData ded Value

0~6 characters

NULL

None

Equipment Planning TMADeviceData

-10~30, step:0.1

None

Default/Recommen TMADeviceData ded Value

0~5 characters

NULL

None

Equipment Planning TMADeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen TMADeviceData ded Value

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen TMADeviceData ded Value

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen TMADeviceData ded Value

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX

UNUSED(UNUSED None )

Default/Recommen TMADeviceData ded Value

0~32 characters

NULL

None

Equipment Planning TMADeviceData

0~17 characters

NULL

None

Equipment Planning TMADeviceData

0~15 characters

NULL

None

Equipment Planning TMADeviceData

0~1073741823.75, step:0.25

None

None

N/A

TMADeviceData

0~1073741823.75, step:0.25

None

None

N/A

TMADeviceData

UNSUPPORT, SUPPORT_BYPAS S, None SUPPORT_VSWR, VSWR/BYPASS, NULL

None

N/A

TMADeviceData

0~63.75, step:0.25

None

None

N/A

TMADeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

TMADeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

TMADeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

TMADeviceData

UNUSED, BandI, BandII, BandIII, BandIV, BandV, BandVI, BandVII, BandVIII, BandIX, BandX, NULL

None

None

N/A

TMADeviceData

0~359

None

None

N/A

TMADeviceData

0~359

None

None

N/A

TMADeviceData

0~359

None

None

N/A

TMADeviceData

0~359

None

None

N/A

TMADeviceData

0~25.5, step:0.1 0~25.5, step:0.1

None None

None None

N/A N/A

TMADeviceData TMADeviceData

0~25.5, step:0.1 0~25.5, step:0.1

None None

None None

N/A N/A

TMADeviceData TMADeviceData

0~65535

None

N/A

TMADeviceData

0~65535

None

N/A

TMADeviceData

0~65535

None

N/A

TMADeviceData

0~65535

None

N/A

TMADeviceData

0~35

None

None

Equipment Planning TMASubunit

1~2

None

None

Equipment Planning TMASubunit

0~17 0~1073741823.75, step:0.25 NORMAL, BYPASS, NULL

None

None

N/A

TMASubunit

None

None

N/A

TMASubunit

None

None

N/A

TMASubunit

AVAILABLE, UNAVAILABLE, BREAKLINK

None

None

N/A

TMASubunit

R0A, R0B, R0C, R0D, R0E, R0F, R0G, R0H

R0A(R0A)

None

Equipment Planning TMASubunit

0~62,255

255

None

Equipment Planning TMASubunit

0~8,255

255

None

Equipment Planning TMASubunit

4~5,60~255

255

None

Equipment Planning TMASubunit

0~63.75, step:0.25

255

None

Radio Planning (Internal planning)

TMASubunit

NORMAL, BYPASS

NORMAL(NORMAL None )

Default/Recommen TMASubunit ded Value

0~62

None

None

Equipment Planning VAntennaPort

60~254

None

None

Equipment Planning VAntennaPort

0 None

None

Equipment Planning VAntennaPort

R0A, R0B, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B, NULL

None

None

Equipment Planning VAntennaPort

60~254

None

None

Equipment Planning VRET

0~62

None

None

Equipment Planning VRET

60~254

None

None

Equipment Planning VRET

0 None

None

Equipment Planning VRET

0~64 characters

None

None

Equipment Planning VRET

88

None

Equipment Planning VRET

0~62

None

None

Equipment Planning VRETSubunit

R0A, R0B, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B, NULL

NULL(NULL)

None

Engineering Design VRETSubunit

R0A, R0B, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B, NULL

NULL(NULL)

None

Engineering Design VRETSubunit

0~64 characters

None

None

Equipment Planning VRETSubunit

60~254

None

None

Equipment Planning VRETSubunit

NEGATIVE_45, POSITIVE_45, HORIZONTAL, POSITIVE_NEGATI VERTICAL, LEFT, None VE_45 RIGHT, POSITIVE_NEGATI VE_45

Equipment Planning VRETSubunit

0 None

None

Equipment Planning VRETSubunit

60~254

None

None

Equipment Planning VRETSubunit

1~8

None

None

Equipment Planning VRETSubunit

R0A, R0B, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B, NULL

NULL(NULL)

None

Engineering Design VRETSubunit

NEGATIVE_45, POSITIVE_45, HORIZONTAL, POSITIVE_NEGATI VERTICAL, LEFT, None VE_45 RIGHT, POSITIVE_NEGATI VE_45

Equipment Planning VRETSubunit

-15~15,3276.7, step:0.1

32767

None

Engineering Design VRETSubunit

-15~15,3276.7, step:0.1

32767

None

Engineering Design VRETSubunit

R0A, R0B, R1A, R1B, R2A, R2B, R3A, R3B, R4A, R4B, R5A, R5B, R6A, R6B, R7A, R7B, NULL

NULL(NULL)

None

Engineering Design VRETSubunit

NEGATIVE_45, POSITIVE_45, HORIZONTAL, POSITIVE_NEGATI VERTICAL, LEFT, None VE_45 RIGHT, POSITIVE_NEGATI VE_45 NEGATIVE_45, POSITIVE_45, HORIZONTAL, POSITIVE_NEGATI VERTICAL, LEFT, None VE_45 RIGHT, POSITIVE_NEGATI VE_45

Equipment Planning VRETSubunit

Equipment Planning VRETSubunit

0,1,2,4

None

Equipment Planning VRETSubunit

0~255

None

None

Equipment Planning CTRLLNK

0~7

None

None

Equipment Planning CTRLLNK

0~1

None

None

Equipment Planning CTRLLNK

0~7

None

None

Equipment Planning CTRLLNK

0~7

None

None

Equipment Planning CTRLLNK

0~1

None

None

Equipment Planning CTRLLNK

0~7

None

None

Equipment Planning CTRLLNK

0~4

None

None

Equipment Planning CTRLLNK

0~4,8

None

None

N/A

CTRLLNK

2000-01-01 00:00:00~2038-12- None 31 23:59:59

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~65535

None

None

N/A

CTRLLNK

0~65535

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~65535

None

None

N/A

CTRLLNK

0~65535

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~65535

None

None

N/A

CTRLLNK

0~65535

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~4294967295

None

None

N/A

CTRLLNK

0~31 characters

None

None

N/A

CTRLLNK

00

Default/Recommen BITS ded Value

0~7

Default/Recommen BITS ded Value

0~1

Default/Recommen BITS ded Value

0~7

Default/Recommen BITS ded Value

DEACTIVATED, ACTIVATED

None

None

N/A

BITS

UNAVAILABLE, AVAILABLE

None

None

N/A

BITS

1~4

Default/Recommen BITS ded Value

00

Default/Recommen LineClk ded Value

0~7

Default/Recommen LineClk ded Value

0~1

Default/Recommen LineClk ded Value

0~5

Default/Recommen LineClk ded Value

0~7

Equipment Planning LineClk

DEACTIVATED, ACTIVATED

None

None

N/A

LineClk

UNAVAILABLE, AVAILABLE

None

None

N/A

LineClk

1~4

Default/Recommen LineClk ded Value

00

Default/Recommen PeerClk ded Value

UMTS, GSM, DEFAULT

DEFAULT(DEFAUL None T)

Default/Recommen PeerClk ded Value

DEACTIVATED, ACTIVATED

None

None

N/A

PeerClk

UNAVAILABLE, AVAILABLE

None

None

N/A

PeerClk

0~1

Equipment Planning TOD

IN, OUT

IN(Input)

IN(Input)

Default/Recommen TOD ded Value

0~7

Default/Recommen TOD ded Value

0~1

Default/Recommen TOD ded Value

0~7

None

Default/Recommen TOD ded Value

TWISTED-PAIR, COAXIAL

TWISTEDNone PAIR(Twisted-Pair)

Equipment Planning TOD

0~1000

None

Equipment Planning TOD

DEACTIVATED, ACTIVATED

None

None

N/A

TOD

UNAVAILABLE, AVAILABLE

None

None

N/A

TOD

0~100000

None

N/A

TOD

1~4

Default/Recommen TOD ded Value

0~17

Equipment Planning GPS

0~7

Default/Recommen GPS ded Value

0~1,60~254

Default/Recommen GPS ded Value

0~7

None

Default/Recommen GPS ded Value

USER_CONFIG, SEARCH_WITH_D URATION, AUTO_SEARCH(A None SEARCH_WITH_P uto Search) RECISION, AUTO_SEARCH

Default/Recommen GPS ded Value

-180~180, step:1e-6 0

None

Equipment Planning GPS

-90~90, step:1e-6

None

Equipment Planning GPS

-1000~10000

None

Equipment Planning GPS

0~89

None

Equipment Planning GPS

0~100000

None

N/A

GPS

1~2880

None

Default/Recommen GPS ded Value

1~100

None

Default/Recommen GPS ded Value

TWISTED-PAIR, COAXIAL

COAXIAL(Coaxial)

None

Equipment Planning GPS

0~1000

None

Equipment Planning GPS

1~63 characters

None

None

N/A

GPS

Lock, Unlock

None

None

N/A

GPS

Valid, Invalid

None

None

N/A

GPS

Valid, Invalid

None

None

N/A

GPS

NotFixed, Fixed

None

None

N/A

GPS

Enabled, Disabled

None

None

N/A

GPS

Valid, Invalid

None

None

N/A

GPS

0~100

None

None

N/A

GPS

NOTEXIST, ANTENNASHORTE D, ANTENNAOPENE D, SELF_CHECK_FAI LURE, None COMEXCEPTION, NORMAL, UNKNOWN, USCUINVALID, UNKNOWN_STAR _CARD

None

N/A

GPS

M12M, UT, RT, JPS15L, K161, GG16, JNS100, RGPS, CWAIN, RTSMT, UBLOX5, None BD7702, NAVIOR, PPSTOD, M1000, TRGPS, BD7702CMS, OEM4, UNKNOWN

None

N/A

GPS

0~100

None

None

N/A

GPS

GPS, GLONASS, GPS/GLONASS, COMPASS, COMPASS/GPS, GPS/COMPASS

GPS(GPS)

GPS(GPS)

Equipment Planning GPS

0~100

None

None

N/A

GPS

DEACTIVATED, ACTIVATED

None

None

N/A

GPS

1~4

Default/Recommen GPS ded Value

0~1

Equipment Planning IPCLKLNK

HW_DEFINED, PTP

PTP(PTP Protocol) PTP(PTP)

Equipment Planning IPCLKLNK

0~7

Equipment Planning IPCLKLNK

0~1

Equipment Planning IPCLKLNK

0~7

None

Equipment Planning IPCLKLNK

Valid IP address

0.0.0.0

None

Equipment Planning IPCLKLNK

Valid IP address

0.0.0.0

None

Equipment Planning IPCLKLNK

0~127

Equipment Planning IPCLKLNK

E2E, P2P

E2E(E2E)

E2E(E2E)

Default/Recommen IPCLKLNK ded Value

OFF, ON

ON(ON)

ON

Default/Recommen IPCLKLNK ded Value

0~255

Default/Recommen IPCLKLNK ded Value

0~255

13

13

Default/Recommen IPCLKLNK ded Value

0~255

Default/Recommen IPCLKLNK ded Value

0~255

14

14

Default/Recommen IPCLKLNK ded Value

0~4294967295

None

None

N/A

IPCLKLNK

NO, YES

NO(NO)

NO(NO)

Default/Recommen IPCLKLNK ded Value

14 characters

0000-0000-0000

None

Default/Recommen IPCLKLNK ded Value

DEACTIVATED, ACTIVATED

None

None

N/A

IPCLKLNK

UNAVAILABLE, AVAILABLE

None

None

N/A

IPCLKLNK

UNICAST, L2_MULTICAST

UNICAST(Unicast) UNICAST(Unicast)

Default/Recommen IPCLKLNK ded Value

-100000~100000

Default/Recommen IPCLKLNK ded Value

ONE_STEP, TWO_STEP

None

None

N/A

IPCLKLNK

0~4094

None

None

N/A

IPCLKLNK

2147483648~21474 None 83647

None

N/A

IPCLKLNK

1~4

Default/Recommen IPCLKLNK ded Value

1/16, 1/8, 1/4, 1/2, 1.0, 2.0, 4.0, 8.0

1/2(1/2)

None

Default/Recommen IPCLKLNK ded Value

1/2, 1.0, 2.0, 4.0, 8.0, 16.0, 32.0, 64.0, 128.0

16.0(16.0)

None

Default/Recommen IPCLKLNK ded Value

0~255

255

None

Default/Recommen IPCLKLNK ded Value

1588V2, G.8265.1

1588V2(1588V2)

None

Default/Recommen IPCLKLNK ded Value

60~1000

300

None

Default/Recommen IPCLKLNK ded Value

IPV4, IPV6

IPV4(IPv4)

None

Default/Recommen IPCLKLNK ded Value

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

IPCLKLNK

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

IPCLKLNK

00

Default/Recommen SyncEth ded Value

0~7

Default/Recommen SyncEth ded Value

0~1

Default/Recommen SyncEth ded Value

0~7

None

Default/Recommen SyncEth ded Value

0~5

Equipment Planning SyncEth

DISABLE, ENABLE

DISABLE(DISABLE None )

Equipment Planning SyncEth

DEACTIVATED, ACTIVATED

None

None

N/A

SyncEth

UNAVAILABLE, AVAILABLE

None

None

N/A

SyncEth

1~4

Default/Recommen SyncEth ded Value

AVAILABLE, UNAVAILABLE, UNSUPPORT, PARTAVAILABLE

None

None

N/A

Tasm

FORBID, ALLOW, NA

None

None

N/A

Tasm

1~4

None

None

N/A

Tasm

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 0(0) 14, 15, 16, 17, AUTO

None

Equipment Planning Tasm

GPS, BITS, IPCLK, SYNCETH, LINECLK, TOD, GPS(GPS Clock) PEERCLK, SYNCETH+IPCLK, GPS+SYNCETH

GPS(GPS Clock)

Equipment Planning Tasm

AUTO, MANUAL, FREE

AUTO(Auto)

AUTO(Auto)

Default/Recommen Tasm ded Value

FREQ, TIME

FREQ(FREQ)

None

Default/Recommen Tasm ded Value

NORMAL, LOST, UNAVAILABLE, FREDVAT, JITTER, None PHASEOUTSCOP E, UNKNOWN, DIFFSRC

None

N/A

Tasm

FREERUNNING, FASTTRACKING, LOCKED, HOLDOVER, UNKNOWN

None

None

N/A

Tasm

GPS, BITS, IPCLK, SYNCETH, LINECLK, TOD, None PEERCLK, SYNCETH+IPCLK, GPS+SYNCETH

None

N/A

Tasm

0~7

None

N/A

Tasm

0~1

None

N/A

Tasm

0~7

None

None

N/A

Tasm

QL-PRC, QL-SSUA, QL-SSU-B, QL- QL-SSU-B(QL-SSUNone EEC2, QL-EEC1, B) QL-DNU

Default/Recommen Tasm ded Value

0~7

None

Equipment Planning BBP

0~1

None

Equipment Planning BBP

0~5

None

None

Equipment Planning BBP

LBBP

LBBP(LBBP)

LBBP(LBBP)

Equipment Planning BBP

FDD, TDD, TDD_ENHANCE, TDD_8T8R, TDD_TL

FDD(Frequency Division Duplex)

FDD(Frequency Division Duplex)

Radio Planning (Internal planning)

BBP

LOCKED, UNLOCKED

UNLOCKED(Unlock UNLOCKED(Unlock Engineering Design BBP ed) ed)

0~4294967295

Engineering Design BBP

IMMEDIATE, DELAY

IMMEDIATE(Immed IMMEDIATE(Immed Engineering Design BBP iate) iate)

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

BBP

Enabled, Disabled

None

None

N/A

BBP

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

BBP

0~2047 characters

None

None

N/A

BBP

0~31 characters 0~31 characters

None None

None None

N/A N/A

BBP BBP

0~259 characters

None

None

N/A

BBP

0~11 characters

None

None

N/A

BBP

0~23 characters

None

None

N/A

BBP

0~19 characters

None

None

N/A

BBP

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

BBP

0~4294967295 0~4294967295

None None

None None

N/A N/A

BBP BBP

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

BBP

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

BBP

None None

N/A N/A

BBP BBP

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

BBP

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

BBP

0~63 characters 0~63 characters

None None

None None

N/A N/A

BBP BBP

0~63 characters

None

None

N/A

BBP

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

BBP BBP

None

None

N/A

BBP

0~65535

None

None

N/A

BBP

0~65535

None

None

N/A

BBP

0~7

None

Equipment Planning BbuFan

0~1

None

Equipment Planning BbuFan

16 None

None

Equipment Planning BbuFan

2147483648~21474 None 83647

None

N/A

BbuFan

0~100

None

None

N/A

BbuFan

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

BbuFan

Enabled, Disabled

None

None

N/A

BbuFan

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

BbuFan

0~2047 characters

None

None

N/A

BbuFan

0~31 characters 0~31 characters

None None

None None

N/A N/A

BbuFan BbuFan

0~259 characters

None

None

N/A

BbuFan

0~11 characters

None

None

N/A

BbuFan

0~23 characters

None

None

N/A

BbuFan

0~19 characters

None

None

N/A

BbuFan

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

BbuFan

0~4294967295 0~4294967295

None None

None None

N/A N/A

BbuFan BbuFan

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

BbuFan

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

BbuFan

None None

N/A N/A

BbuFan BbuFan

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

BbuFan

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

BbuFan

0~63 characters 0~63 characters

None None

None None

N/A N/A

BbuFan BbuFan

0~63 characters

None

None

N/A

BbuFan

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

BbuFan BbuFan

None

None

N/A

BbuFan

0~65535

None

None

N/A

BbuFan

0~65535

None

None

N/A

BbuFan

0~62

None

None

Equipment Planning CCU

15 15

15

Radio Planning (Internal planning)

CCU

00

Radio Planning (Internal planning)

CCU

0~62

None

Equipment Planning CCU

0~1

None

Equipment Planning CCU

0~1

Equipment Planning CCU

NO, YES

YES(YES)

Based on the Equipment Planning CCU physical connection

1~7

None

None

Equipment Planning CCU

GSM, UMTS, LTE

GSM:NO, Based on the Equipment Planning CCU UMTS:NO, LTE:NO physical connection

WS_DISABLE, SS_DISABLE

Water-Immersed Sensor Disabled:ON, Smog Sensor Disabled:ON

It is recommended that WaterImmersed Sensor Disabled be set to ON, Smog Sensor Disabled be set to ON.

Equipment Planning CCU

CONNECTED, DISCONNECTED

None

None

N/A

CCU

CONNECTED, DISCONNECTED

None

None

N/A

CCU

0~4294967295 0~4294967295

None None

None None

N/A N/A

CCU CCU

0~4294967295

None

None

N/A

CCU

0~249

None

Default/Recommen CPRILBR ded Value

LBR0, LBR1, LBR2, LBR3, LBR4, LBR5, None LBR6

None

N/A

CPRILBR

NEGOTIATED, NEGOTIATING, NOTREADY, TIMEOUT, USERCONFIG

None

None

N/A

CPRILBR

LBR0, LBR1, LBR2, LBR3, LBR4, LBR5, None LBR6

None

N/A

CPRILBR

NEGOTIATED, NEGOTIATING, NOTREADY, TIMEOUT, USERCONFIG

None

None

N/A

CPRILBR

0~62 0~254 0~7

None None None

None None None

N/A N/A N/A

CPRILBR CPRILBR CPRILBR

HEAD, TAIL

None

None

N/A

CPRILBR

LBR0, LBR1, LBR2, LBR3, LBR4, LBR5, None LBR6

None

N/A

CPRILBR

0~62

None

Equipment Planning CpriPort

0~1,4~5,60~254

None

Equipment Planning CpriPort

0~8

None

None

Equipment Planning CpriPort

0~5

None

None

Equipment Planning CpriPort

614M, 1.25G, 2.5G, 4.9G, 6.1G, 9.8G, None UNKNOWN, NULL

None

N/A

CpriPort

LOCKED, UNLOCKED, SHUTINGDOWN, INVALID

None

None

N/A

CpriPort

INPOSITION, NOTINPOSITION, INVALID

None

None

N/A

CpriPort

Slave, Master, NULL

None

None

N/A

CpriPort

SFP_OPTICAL, ESFP_OPTICAL, SFP_ELECTRIC, SCSI_ELECTRIC, GE, UNKNOWN, NULL

None

None

N/A

CpriPort

0~4294967295

None

None

N/A

CpriPort

0~4294967295

None

None

N/A

CpriPort

0~4294967295

None

None

N/A

CpriPort

0~4294967295

None

None

N/A

CpriPort

0~4294967295

None

None

N/A

CpriPort

CPRI_MUX, NORMAL, None UNKNOWN, NULL

None

N/A

CpriPort

DC, AC

DC(DC)

None

Equipment Planning ENERGYCON

0~7

None

Equipment Planning MPT

0~1

None

Equipment Planning MPT

6~7

None

None

Equipment Planning MPT

UMPT, LMPT

None

None

Equipment Planning MPT

Unknown, NULL, Active, Standby

None

None

N/A

MPT

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

MPT

Enabled, Disabled

None

None

N/A

MPT

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

MPT

0~2047 characters

None

None

N/A

MPT

0~31 characters 0~31 characters

None None

None None

N/A N/A

MPT MPT

0~259 characters

None

None

N/A

MPT

0~11 characters

None

None

N/A

MPT

0~23 characters

None

None

N/A

MPT

0~19 characters

None

None

N/A

MPT

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

MPT

0~4294967295 0~4294967295

None None

None None

N/A N/A

MPT MPT

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

MPT

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

MPT

None None

N/A N/A

MPT MPT

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

MPT

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

MPT

0~63 characters 0~63 characters

None None

None None

N/A N/A

MPT MPT

0~63 characters

None

None

N/A

MPT

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

MPT MPT

None

None

N/A

MPT

0~65535

None

None

N/A

MPT

0~65535

None

None

N/A

MPT

0~7

None

Equipment Planning PEU

0~1

None

Equipment Planning PEU

18~19

None

None

Equipment Planning PEU

NULL NULL

None None

None None

N/A N/A

PEU PEU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

PEU

Enabled, Disabled

None

None

N/A

PEU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

PEU

0~2047 characters

None

None

N/A

PEU

0~31 characters 0~31 characters

None None

None None

N/A N/A

PEU PEU

0~259 characters

None

None

N/A

PEU

0~11 characters

None

None

N/A

PEU

0~23 characters

None

None

N/A

PEU

0~19 characters

None

None

N/A

PEU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

PEU

0~4294967295 0~4294967295

None None

None None

N/A N/A

PEU PEU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

PEU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

PEU

None None

N/A N/A

PEU PEU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

PEU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

PEU

0~63 characters 0~63 characters

None None

None None

N/A N/A

PEU PEU

0~63 characters

None

None

N/A

PEU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

PEU PEU

None

None

N/A

PEU

0~65535

None

None

N/A

PEU

0~65535

None

None

N/A

PEU

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Engineering Design PSUIS

0~62

None

None

Equipment Planning SFP

0~1,4~5,60~254

None

None

Equipment Planning SFP

0~8

None

None

Equipment Planning SFP

0~8

None

None

Equipment Planning SFP

INPOSITION, NOTINPOSITION, INVALID

None

None

N/A

SFP

SFP, ESFP, SFP_ELECTRIC, QSFP, EQSFP, UNKNOWN

None

None

N/A

SFP

0~15 characters

None

None

N/A

SFP

SINGLEMODE, MULTIMODE, UNKNOWN

None

None

N/A

SFP

0~65535

None

None

N/A

SFP

0~25500, step:100

None

None

N/A

SFP

0~255

None

None

N/A

SFP

0~25500, step:100

None

None

N/A

SFP

0~2550, step:10

None

None

N/A

SFP

0~2550, step:10

None

None

N/A

SFP

-128~128, step:0.1

None

None

N/A

SFP

0~6553500, step:100

None

None

N/A

SFP

0~131070, step:2

None

None

N/A

SFP

0~6553.5, step:0.1

None

None

N/A

SFP

0~6553.5, step:0.1

None

None

N/A

SFP

0~255

None

None

N/A

SFP

0~7

None

Equipment Planning TRP

0~1

None

Equipment Planning TRP

0~6

None

None

Equipment Planning TRP

UIEB, UTRPc

None

None

Equipment Planning TRP

Unknown, NULL, Active, Standby

None

None

N/A

TRP

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

TRP

Enabled, Disabled

None

None

N/A

TRP

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

TRP

0~2047 characters

None

None

N/A

TRP

0~31 characters 0~31 characters

None None

None None

N/A N/A

TRP TRP

0~259 characters

None

None

N/A

TRP

0~11 characters

None

None

N/A

TRP

0~23 characters

None

None

N/A

TRP

0~19 characters

None

None

N/A

TRP

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

TRP

0~4294967295 0~4294967295

None None

None None

N/A N/A

TRP TRP

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

TRP

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

TRP

None None

N/A N/A

TRP TRP

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

TRP

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

TRP

0~63 characters 0~63 characters

None None

None None

N/A N/A

TRP TRP

0~63 characters

None

None

N/A

TRP

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

TRP TRP

None

None

N/A

TRP

0~65535

None

None

N/A

TRP

0~65535

None

None

N/A

TRP

0~7

None

None

Equipment Planning UCIU

0~1 0~7

None None

None None

Equipment Planning UCIU Equipment Planning UCIU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

UCIU

Enabled, Disabled

None

None

N/A

UCIU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

UCIU

0~2047 characters

None

None

N/A

UCIU

0~31 characters 0~31 characters

None None

None None

N/A N/A

UCIU UCIU

0~259 characters

None

None

N/A

UCIU

0~11 characters

None

None

N/A

UCIU

0~23 characters

None

None

N/A

UCIU

0~19 characters

None

None

N/A

UCIU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

UCIU

0~4294967295 0~4294967295

None None

None None

N/A N/A

UCIU UCIU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

UCIU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

UCIU

None None

N/A N/A

UCIU UCIU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

UCIU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

UCIU

0~63 characters 0~63 characters

None None

None None

N/A N/A

UCIU UCIU

0~63 characters

None

None

N/A

UCIU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

UCIU UCIU

None

None

N/A

UCIU

0~65535

None

None

N/A

UCIU

0~65535

None

None

N/A

UCIU

0~7

None

Equipment Planning UEIU

0~1

None

Equipment Planning UEIU

18~19

None

None

Equipment Planning UEIU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

UEIU

Enabled, Disabled

None

None

N/A

UEIU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

UEIU

0~2047 characters

None

None

N/A

UEIU

0~31 characters 0~31 characters

None None

None None

N/A N/A

UEIU UEIU

0~259 characters

None

None

N/A

UEIU

0~11 characters

None

None

N/A

UEIU

0~23 characters

None

None

N/A

UEIU

0~19 characters

None

None

N/A

UEIU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

UEIU

0~4294967295 0~4294967295

None None

None None

N/A N/A

UEIU UEIU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

UEIU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

UEIU

None None

N/A N/A

UEIU UEIU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

UEIU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

UEIU

0~63 characters 0~63 characters

None None

None None

N/A N/A

UEIU UEIU

0~63 characters

None

None

N/A

UEIU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

UEIU UEIU

None

None

N/A

UEIU

0~65535

None

None

N/A

UEIU

0~65535

None

None

N/A

UEIU

0~7

None

Equipment Planning USCU

0~1

None

Equipment Planning USCU

0~5

None

None

Equipment Planning USCU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

USCU

Enabled, Disabled

None

None

N/A

USCU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

USCU

0~2047 characters

None

None

N/A

USCU

0~31 characters 0~31 characters

None None

None None

N/A N/A

USCU USCU

0~259 characters

None

None

N/A

USCU

0~11 characters

None

None

N/A

USCU

0~23 characters

None

None

N/A

USCU

0~19 characters

None

None

N/A

USCU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

USCU

0~4294967295 0~4294967295

None None

None None

N/A N/A

USCU USCU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

USCU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

USCU

None None

N/A N/A

USCU USCU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

USCU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

USCU

0~63 characters 0~63 characters

None None

None None

N/A N/A

USCU USCU

0~63 characters

None

None

N/A

USCU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

USCU USCU

None

None

N/A

USCU

0~65535

None

None

N/A

USCU

0~65535

None

None

N/A

USCU

0~64 characters

NULL

None

Equipment Planning Equipment

ON, OFF

OFF(OFF)

None

Engineering Design Equipment

ON, OFF

OFF(OFF)

None

Engineering Design Equipment

NORMAL, INSTALL, EXPAND, UPGRADE, TESTING, ExpandStatus1, ExpandStatus2, ExpandStatus3, ExpandStatus4, ExpandStatus5, ExpandStatus6, ExpandStatus7, ExpandStatus8, ExpandStatus9, ExpandStatus10

NORMAL(NORMAL None )

Engineering Design Equipment

2000-0101T00:00:00+00:00 2000-01None ~2037-1201T00:00:00+00:00 31T23:59:59+00:00

Engineering Design Equipment

2000-0101T00:00:00+00:00 2037-12None ~2037-1231T23:59:59+00:00 31T23:59:59+00:00

Engineering Design Equipment

0~255 characters

None

None

Engineering Design Equipment

NORMAL, INSTALL, EXPAND, UPGRADE, TESTING, ExpandStatus1, ExpandStatus2, ExpandStatus3, ExpandStatus4, ExpandStatus5, ExpandStatus6, ExpandStatus7, ExpandStatus8, ExpandStatus9, ExpandStatus10

None

None

N/A

Equipment

DISABLE, ENABLE DISABLE(Disable)

None

Equipment Planning Equipment

39.0~48.0, step:0.1 450

None

Equipment Planning Equipment

39.0~60.0, step:0.1 455

None

Equipment Planning Equipment

0~62

None

None

Equipment Planning Cabinet

APM30, TMC, BBC, PS4890, OMB, RFC, BTS3900, VIRTUAL(Virtual BTS3900L, Cabinet) BTS3900AL, VIRTUAL, TP48600A, ILC29

None

Equipment Planning Cabinet

0~79 characters

NULL

None

Equipment Planning Cabinet

0~31 characters

None

None

N/A

Cabinet

0~62

None

None

Equipment Planning Subrack

0~254

None

None

Equipment Planning Subrack

BBU3900, RFU, PMU, TCU, FMU, RRU, EMU, PICO, CCU, UNKNOW

None

None

Equipment Planning Subrack

0~79 characters

NULL

None

Engineering Design Subrack

AC220V, DC-48V, DC+28V, DC+24V, DC-48V-2, AC110V, None RDC-48V, NDC48V

None

N/A

Subrack

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

RU

Enabled, Disabled

None

None

N/A

RU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

RU

0~2047 characters

None

None

N/A

RU

0~31 characters

None

None

N/A

RU

0~31 characters

None

None

N/A

RU

0~259 characters

None

None

N/A

RU

0~11 characters

None

None

N/A

RU

0~23 characters

None

None

N/A

RU

0~19 characters

None

None

N/A

RU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

RU

0~4294967295 0~4294967295

None None

None None

N/A N/A

RU RU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

RU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

RU

None None

N/A N/A

RU RU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

RU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

RU

0~63 characters 0~63 characters

None None

None None

N/A N/A

RU RU

0~63 characters

None

None

N/A

RU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

RU RU

None

None

N/A

RU

0~65535

None

None

N/A

RU

0~65535

None

None

N/A

RU

0~62

Default/Recommen EMU ded Value

40~59

40

40

Default/Recommen EMU ded Value

00

Default/Recommen EMU ded Value

0~62

Default/Recommen EMU ded Value

0~254

Default/Recommen EMU ded Value

0~7

None

When the EMU is connected to the MON1 port on the UPEU, set this parameter to 1. When the EMU is connected to the MON0 port on the UPEU, set this Default/Recommen EMU parameter to 0. ded Value When the EMU is connected to the RRU, set this parameter to 0.When the EMU is connected to the CCU, set this parameter to 0~7.

1~30

Default/Recommen EMU ded Value

-20~80

Default/Recommen EMU ded Value

-20~80

50

50

Default/Recommen EMU ded Value

0~100

10

10

Default/Recommen EMU ded Value

0~100

80

80

Default/Recommen EMU ded Value

48V_DISABLE, RES0, RES1, RES2, TS_DISABLE, HS_DISABLE

It is recommended that -48 Voltage -48 Voltage Disabled be set to Disabled:OFF, OFF, Reserved Reserved Sensor Sensor 0 be set to 0:ON, Reserved ON, Reserved Sensor 1:ON, Sensor 1 be set to Reserved Sensor ON, Reserved Equipment Planning EMU 2:ON, Temperature Sensor 2 be set to Sensor ON, Temperature Disabled:OFF, Sensor Disabled be Humidity Sensor set to OFF, and Disabled:OFF Humidity Sensor Disabled be set to OFF. It is recommended that WaterImmersed Sensor Disabled be set to OFF, Smog Sensor Disabled be set to Equipment Planning EMU OFF, Infrared Sensor Disabled be set to ON, and Gating Sensor Disabled be set to OFF. None None N/A N/A EMU EMU

WS_DISABLE, SS_DISABLE, IS_DISABLE, GS_DISABLE

Water -Immersed Sensor Disabled:OFF, Smog Sensor Disabled:OFF, Infrared Sensor Disabled:ON, Gating Sensor Disabled:OFF

2147483648~21474 None 83647 0~100 None

0.0~100.0

None

None

N/A

EMU

-999.99~9999.99

None

None

N/A

EMU

-999.99~9999.99

None

None

N/A

EMU

-999.99~9999.99

None

None

N/A

EMU

-999.99~9999.99

None

None

N/A

EMU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

EMU

Enabled, Disabled

None

None

N/A

EMU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

EMU

0~2047 characters

None

None

N/A

EMU

0~31 characters 0~31 characters

None None

None None

N/A N/A

EMU EMU

0~259 characters

None

None

N/A

EMU

0~11 characters

None

None

N/A

EMU

0~23 characters

None

None

N/A

EMU

0~19 characters

None

None

N/A

EMU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

EMU

0~4294967295 0~4294967295

None None

None None

N/A N/A

EMU EMU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

EMU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

EMU

None None

N/A N/A

EMU EMU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

EMU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

EMU

0~63 characters 0~63 characters

None None

None None

N/A N/A

EMU EMU

0~63 characters

None

None

N/A

EMU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

EMU EMU

None

None

N/A

EMU

0~65535

None

None

N/A

EMU

0~65535

None

None

N/A

EMU

0~62

Default/Recommen FMU ded Value

11~12

11

11

Default/Recommen FMU ded Value

00

Default/Recommen FMU ded Value

0~62

Default/Recommen FMU ded Value

0~254

Default/Recommen FMU ded Value

0~7

None

When the FMU is connected to the MON1 port on the UPEU, set this parameter to 1. When the FMU is connected to the MON0 port on the UPEU, set this parameter to 0. When the FMU is connected to the RRU, set this parameter to 0. When the FMU is connected to the CCU, set this parameter to a value within the range of 0 to 7.

Default/Recommen FMU ded Value

1~30

14

The FMUs of a maximum of two levels can be connected to a bus. The communication address of the FMU Default/Recommen that is directly FMU ded Value connected to the BBU is set to 14. The communication address of the lowerlevel FMU is set to 15.

WS_DISABLE, SS_DISABLE

Water-Immersed Sensor Disabled:ON, Smog Sensor Disabled:ON

Water-Immersed Sensor Default/Recommen Disabled:ON, Smog FMU ded Value Sensor Disabled:ON

0~100

None

None

N/A

FMU

-127~127

None

None

N/A

FMU

-127~127

None

None

N/A

FMU

0~4294967295

None

None

N/A

FMU

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Engineering Design FMU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

FMU

Enabled, Disabled

None

None

N/A

FMU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

FMU

0~2047 characters

None

None

N/A

FMU

0~31 characters 0~31 characters

None None

None None

N/A N/A

FMU FMU

0~259 characters

None

None

N/A

FMU

0~11 characters

None

None

N/A

FMU

0~23 characters

None

None

N/A

FMU

0~19 characters

None

None

N/A

FMU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

FMU

0~4294967295 0~4294967295

None None

None None

N/A N/A

FMU FMU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

FMU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

FMU

None None

N/A N/A

FMU FMU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

FMU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

FMU

0~63 characters 0~63 characters

None None

None None

N/A N/A

FMU FMU

0~63 characters

None

None

N/A

FMU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

FMU FMU

None

None

N/A

FMU

0~65535

None

None

N/A

FMU

0~65535

None

None

N/A

FMU

0~62

Default/Recommen TCU ded Value

8,14

Default/Recommen TCU ded Value

0~3

Default/Recommen TCU ded Value

0~62

Default/Recommen TCU ded Value

0~254

Default/Recommen TCU ded Value

0~7

None

When the TCU is connected to the MON1 port on the UPEU, set this parameter to 1. When the TCU is connected to the MON0 port on the UPEU, set this parameter to 0. When the TCU is connected to the RRU, set this parameter to 0. When the TCU is connected to the CCU, set this parameter to a value within the range of 0 to 7.

Default/Recommen TCU ded Value

1~30

If the manager unit of the TCU is a CCU, no matter the TCU is configured in a BBC or not, it is recommended that the communication address of the TCU used for heat dissipation be set to 6 or 7 and that of the TCU used for heating be set to 28 or 29. If the manager unit of the TCU is a BBU and the TCU Default/Recommen TCU is not configured in ded Value a BBC, it is recommended that the communication address of the TCU used for heat dissipation be set to 6 or 7 and that of the TCU used for heating be set to 28 or 29. For the TCU configured in a BBC, if the communication address of the PMU connected to the BBC is 3, the

-40~10

-20

-20

Default/Recommen TCU ded Value

20~80

68

For the TCU in the BBC, the recommended value is 50. For the Default/Recommen TCU TCU in another ded Value cabinet, the recommended value is 68.

WS_DISABLE, SS_DISABLE

Water-Immersed Sensor Disabled:ON, Smog Sensor Disabled:ON

Water-Immersed Sensor Default/Recommen Disabled:ON, Smog TCU ded Value Sensor Disabled:ON

0~3 characters -127~127

None None

None None

N/A N/A

TCU TCU

-127~127

None

None

N/A

TCU

-127~127

None

None

N/A

TCU

0~4294967295

None

None

N/A

TCU

0~4294967295

None

None

N/A

TCU

0~4294967295

None

None

N/A

TCU

0~4294967295 0~4294967295

None None

None None

N/A N/A

TCU TCU

0~4294967295

None

None

N/A

TCU

0~18 characters

None

None

N/A

TCU

0~32 characters

None

None

N/A

TCU

0~18 characters

None

None

N/A

TCU

dantherm, bw, huawei, air-sys, senguang, viasystems, rittal, emerson, APW, hytems, hontech, agisson, pantair, Panasonic, Gore, Flex, Vapel, AVC, JIAYI, Delta, EBM, Protechnic, Sanyo

None

None

N/A

TCU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

TCU

Enabled, Disabled

None

None

N/A

TCU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

TCU

0~2047 characters

None

None

N/A

TCU

0~31 characters 0~31 characters

None None

None None

N/A N/A

TCU TCU

0~259 characters

None

None

N/A

TCU

0~11 characters

None

None

N/A

TCU

0~23 characters

None

None

N/A

TCU

0~19 characters

None

None

N/A

TCU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

TCU

0~4294967295 0~4294967295

None None

None None

N/A N/A

TCU TCU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

TCU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

TCU

None None

N/A N/A

TCU TCU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

TCU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

TCU

0~63 characters 0~63 characters

None None

None None

N/A N/A

TCU TCU

0~63 characters

None

None

N/A

TCU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

TCU TCU

None

None

N/A

TCU

0~65535

None

None

N/A

TCU

0~65535

None

None

N/A

TCU

0~62

Default/Recommen HtCDPa ded Value

8,14

Default/Recommen HtCDPa ded Value

0~3

Default/Recommen HtCDPa ded Value

-99~70

Default/Recommen HtCDPa ded Value

-99~70

40

40

Default/Recommen HtCDPa ded Value

-99~70

45

45

Default/Recommen HtCDPa ded Value

0~30

Default/Recommen HtCDPa ded Value

0~30

Default/Recommen HtCDPa ded Value

0~30

16

16

Default/Recommen HtCDPa ded Value

0~30

13

13

Default/Recommen HtCDPa ded Value

0~62

Default/Recommen PMU ded Value

77

Default/Recommen PMU ded Value

00

Default/Recommen PMU ded Value

0~62

Default/Recommen PMU ded Value

0~254

Default/Recommen PMU ded Value

0~7

None

When the PMU is connected to the MON1 port on the UPEU, set this parameter to 1. When the PMU is connected to the MON0 port on the UPEU, set this parameter to 0. When the PMU is connected to the RRU, set this parameter to 0. When the PMU is connected to the CCU, set this parameter to a value within the range of 0 to 7.

Default/Recommen PMU ded Value

1~30

Default/Recommen PMU ded Value

APM100, APM200, APM30, EPS4890, EPS4815, APM30(APM 30) SC48200, EPS48200, TP48300A, ETP

APM30(APM 30)

Equipment Planning PMU

60~300

180

180

Default/Recommen PMU ded Value

60~300

280

280

Default/Recommen PMU ded Value

35.0~55.6, step:0.1 450

The recommended value of this parameter for the SC48200 PMU is 470. The Default/Recommen PMU recommended ded Value value of this parameter for other types of PMU is 450.

58.0~60.0, step:0.1 580

The recommended value of this parameter for the SC48200 PMU is 585. The Default/Recommen PMU recommended ded Value value of this parameter for other types of PMU is 580.

DISABLE, ENABLE DISABLE(Disable)

The recommended value of this parameter for the SC48200 PMU is ENABLE(Enable). Default/Recommen PMU The recommended ded Value value of this parameter for other types of PMU is DISABLE(Disable).

35.0~55.6, step:0.1 440

The recommended value of this parameter for the SC48200 PMU is 465. The Default/Recommen PMU recommended ded Value value of this parameter for other types of PMU is 440.

-20~20

Default/Recommen PMU ded Value

35~80

50

50

Default/Recommen PMU ded Value

0~50

10

10

Default/Recommen PMU ded Value

50~100

80

80

Default/Recommen PMU ded Value

BT1_DISABLE, AH_DISABLE, AT1_DISABLE, BT2_DISABLE

Battery Temperature Sensor 1 Disabled:OFF, Cabinet Humidity Sensor Disabled:ON, Cabinet Temperature Sensor 1 Disabled:ON, Battery Temperature Sensor 2 Disabled:ON

It is recommended that Battery Temperature Sensor 1 Disabled be set to OFF for PMUs in the APM30, PS4890, and SC48200 and ON for other PMUs, Cabinet Humidity Sensor Disabled be Default/Recommen set to ON, Cabinet PMU ded Value Temperature Sensor 1 Disabled be set to OFF for PMUs in the APM100 and APM200 and ON for other PMUs, and Battery Temperature Sensor 2 Disabled be set to ON.

WS_DISABLE, SS_DISABLE, GS_DISABLE

It is recommended that WaterImmersed Sensor Water-Immersed Disabled be set to Sensor ON, Smog Sensor Disabled:ON, Smog Disabled be set to Default/Recommen Sensor ON, and Gating PMU ded Value Disabled:ON, Sensor Disabled be Gating Sensor set to OFF for Disabled:OFF PMUs in the APM30, APM100, and APM200 and ON for other PMUs.

2147483648~21474 None 83647

None

N/A

PMU

-100.0~100.0 -150.0~150.0

None None

None None

N/A N/A

PMU PMU

2147483648~21474 None 83647 0~100 None

None

N/A

PMU

None

N/A

PMU

PowerOn, LowVoltagePowerO ff, MasterControlPowe rOff, None HighTemperaturePo werOff, LowTemperaturePo werOff

None

N/A

PMU

BoostCharging, FloatCharging, ForceBoostChargin None g, Discharging, Sleeping

None

N/A

PMU

-150.0~150.0

None

None

N/A

PMU

CurrentLimiting, NoCurrentLimiting

None

None

N/A

PMU

PowerOn, LowVoltagePowerO ff, MasterControlPowe None rOff, ManualPowerOff, HighTemperaturePo werOff

None

N/A

PMU

0~100

None

None

N/A

PMU

2147483648~21474 None 83647 CHARGE, DISCHARGE, REC, None END

None

N/A

PMU

None

N/A

PMU

-150.0~150.0

None

None

N/A

PMU

-150.0~150.0

None

None

N/A

PMU

2147483648~21474 None 83647

None

N/A

PMU

0~4294967295 0~4294967295

None None

None None

N/A N/A

PMU PMU

0~4294967295

None

None

N/A

PMU

0~18 characters

None

None

N/A

PMU

0~32 characters

None

None

N/A

PMU

0~18 characters

None

None

N/A

PMU

Huawei, Emerson, Holdluck-ZYT, Power-One, Kehua, DeltaElectronics, EltekEnergy, Switchtec, TycoElectronics, ARTESYN, None CHROMA, LuckyValley, ACBEL, Zippy, GuoyaoElectronics, DPC, GoldPower, SungrowPowerSup ply, Ecom

None

N/A

PMU

UNSUPPORTED, SUPPORTED

None

None

N/A

PMU

DISABLE, ENABLE None

None

N/A

PMU

SUCCEEDED, BRDNOTREADY, UNSUPPORTED, BATNOTEXIST, INTERNALERR

None

None

N/A

PMU

0~65535

None

None

N/A

PMU

0~4294967295

None

None

N/A

PMU

0~4294967295

None

None

N/A

PMU

UNSUPPORTED, SUPPORTED

None

None

N/A

PMU

DISABLE, ENABLE None

None

N/A

PMU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

PMU

Enabled, Disabled

None

None

N/A

PMU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

PMU

0~2047 characters

None

None

N/A

PMU

0~31 characters 0~31 characters

None None

None None

N/A N/A

PMU PMU

0~259 characters

None

None

N/A

PMU

0~11 characters

None

None

N/A

PMU

0~23 characters

None

None

N/A

PMU

0~19 characters

None

None

N/A

PMU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

PMU

0~4294967295 0~4294967295

None None

None None

N/A N/A

PMU PMU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

PMU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

PMU

None None

N/A N/A

PMU PMU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

PMU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

PMU

0~63 characters 0~63 characters

None None

None None

N/A N/A

PMU PMU

0~63 characters

None

None

N/A

PMU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

PMU PMU

None

None

N/A

PMU

0~65535

None

None

N/A

PMU

0~65535

None

None

N/A

PMU

0~62

Default/Recommen DieselGen ded Value

77

Default/Recommen DieselGen ded Value

00

Default/Recommen DieselGen ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen DieselGen ded Value

0.1~100.0, step:0.1 125

125

Default/Recommen DieselGen ded Value

1~7 characters

None

None

N/A

DieselGen

-150.0~150.0

None

None

N/A

DieselGen

0~4294967295

None

None

N/A

DieselGen

0~62

Default/Recommen Battery ded Value

77

Default/Recommen Battery ded Value

00

Default/Recommen Battery ded Value

INNER, OUTER

INNER(Inner)

The battery installation type of the SC48200 PMU is OUTER. The battery installation type of other types of PMU should be set based on the actual situation.

Equipment Planning Battery

30~240

60

60

Default/Recommen Battery ded Value

43.3~57.6, step:0.1 565

565

Default/Recommen Battery ded Value

5~5000

36

Based on the PMU type: The recommended value for the APM30 is 30. The recommended value for the APM100 is 100. The recommended value for the Engineering Design Battery APM200 is 200. The recommended value for the PS4890 is 30. The recommended value for the EPS4815 is 65. The recommended value for the SC48200 is 1000.

0.05~0.25, step:0.01

15

15

Default/Recommen Battery ded Value

43.2~57.5, step:0.1 535

535

Default/Recommen Battery ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen Battery ded Value

40~70

53

The recommended value of this parameter for the SC48200 PMU is Default/Recommen 60. The Battery ded Value recommended value of this parameter for other types of PMU is 53.

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen Battery ded Value

35.0~55.6, step:0.1 430

The recommended value of this parameter for the SC48200 PMU is 460. The Default/Recommen Battery recommended ded Value value of this parameter for other types of PMU is 430.

0~500

80

80

Default/Recommen Battery ded Value

-20~20

-19

-19

Default/Recommen Battery ded Value

35~80

50

50

Default/Recommen Battery ded Value

1~2

Engineering Design Battery

VRLA_BAT, LI_BAT

VRLA_BAT(VRLA Battery)

VRLA_BAT(VRLA Battery)

Engineering Design Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

0~4294967295

None

None

N/A

Battery

2000-01-01~209912-31

None

None

N/A

Battery

5~5000

36

Based on the PMU type: The recommended value for the APM30 is 30. The recommended value for the APM100 is 100. The recommended value for the Engineering Design Battery APM200 is 200. The recommended value for the PS4890 is 30. The recommended value for the EPS4815 is 65. The recommended value for the SC48200 is 1000.

0~62

Default/Recommen BatCTPa ded Value

77

Default/Recommen BatCTPa ded Value

00

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

1200

1200

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

600

600

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

300

300

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

150

150

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

100

100

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

70

70

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

50

50

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

40

40

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

30

30

Default/Recommen BatCTPa ded Value

0.01~50.00, step:0.01

25

25

Default/Recommen BatCTPa ded Value

80~100

80

80

Default/Recommen BatCTPa ded Value

1.70~2.20, step:0.01

190

190

Default/Recommen BatCTPa ded Value

1~50

24

24

Default/Recommen BatCTPa ded Value

1~100

10

10

Default/Recommen BatCTPa ded Value

1~240

60

60

Default/Recommen BatCTPa ded Value

40.0~54.0, step:0.1 450

450

Default/Recommen BatCTPa ded Value

NOAUTOTEST, PERIOD, POWERCUT(Powe POWERCUT(Powe Default/Recommen POWERCUT, BatCTPa r Off Auto Test) r Off Auto Test) ded Value PERIODPOWERC UT

30~240

120

120

Default/Recommen BatCTPa ded Value

1~60

14

14

Default/Recommen BatCTPa ded Value

STANDARD, SIMPLE, TIMER, PWROFF, NONE

None

None

N/A

BatCTPa

2000-01-01 00:00:00~2038-12- None 31 23:59:59

None

N/A

BatCTPa

BelowEndVol, OverTime, CurrRecover, ManualEnd, AlmEnd

None

None

N/A

BatCTPa

None, Normal, PreAlm, Alm

None

None

N/A

BatCTPa

0~100

None

None

N/A

BatCTPa

1~7 characters

None

None

N/A

BatCTPa

-100.00~100.00

None

None

N/A

BatCTPa

-150.0~150.0

None

None

N/A

BatCTPa

0~4294967295

None

None

N/A

BatCTPa

2147483648~21474 None 83647 0~62 0

None

N/A

BatCTPa

Default/Recommen PSU ded Value

77

Default/Recommen PSU ded Value

1~7

None

Default/Recommen PSU ded Value

NORMAL, COMMUNICATEFA ILED, SHUTDOWN, None FAULT, PROTECT, UNCONFIGURED, ILLEGAL

None

N/A

PSU

0~18 characters

None

None

N/A

PSU

Huawei, Emerson, Holdluck-ZYT, Power-One, Kehua, DeltaElectronics, EltekEnergy, Switchtec, TycoElectronics, ARTESYN, None CHROMA, LuckyValley, ACBEL, Zippy, GuoyaoElectronics, DPC, GoldPower, SungrowPowerSup ply, Ecom

None

N/A

PSU

0~4294967295

None

None

N/A

PSU

0~4294967295

None

None

N/A

PSU

0~18 characters

None

None

N/A

PSU

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

PSU

Enabled, Disabled

None

None

N/A

PSU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

PSU

0~2047 characters

None

None

N/A

PSU

0~31 characters 0~31 characters

None None

None None

N/A N/A

PSU PSU

0~259 characters

None

None

N/A

PSU

0~11 characters

None

None

N/A

PSU

0~23 characters

None

None

N/A

PSU

0~19 characters

None

None

N/A

PSU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

PSU

0~4294967295 0~4294967295

None None

None None

N/A N/A

PSU PSU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

PSU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

PSU

None None

N/A N/A

PSU PSU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

PSU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

PSU

0~63 characters 0~63 characters

None None

None None

N/A N/A

PSU PSU

0~63 characters

None

None

N/A

PSU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

PSU PSU

None

None

N/A

PSU

0~65535

None

None

N/A

PSU

0~65535

None

None

N/A

PSU

0~62

Engineering Design OutPort

40~59

40

40

Engineering Design OutPort

00

Engineering Design OutPort

0~5

None

None

Engineering Design OutPort

0~50 characters

NULL

None

Engineering Design OutPort

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design OutPort

0~62

None

None

Engineering Design AlmPort

0~1,7~8,11~12,14~ None 15,40~254

None

Engineering Design AlmPort

0~3,18~19

None

None

Engineering Design AlmPort

0~35

None

None

Engineering Design AlmPort

OFF, ON

OFF(Off)

OFF(Off)

Equipment Planning AlmPort

65033~65233

65033

65033

Equipment Planning AlmPort

BOOL, VALUE

BOOL(Digital Port)

BOOL(Digital Port)

Equipment Planning AlmPort

HIGH, LOW

LOW(Low Voltage) LOW(Low Voltage) Equipment Planning AlmPort

-999.99~9999.99, step:0.01

9900

9900

Equipment Planning AlmPort

-999.99~9999.99, step:0.01

100

100

Equipment Planning AlmPort

VOLTAGE, CURRENT

VOLTAGE(Voltage VOLTAGE(Voltage Equipment Planning AlmPort Type) Type)

-999.99~9999.99, step:0.01

10000

10000

Equipment Planning AlmPort

-999.99~9999.99, step:0.01

Equipment Planning AlmPort

0~9999.99, step:0.01

100

100

Equipment Planning AlmPort

0~9999.99, step:0.01

Equipment Planning AlmPort

ALL, SSL

ALL(All Type)

None

Default/Recommen SSL ded Value

NONE, PEER

PEER(Verify Peer Certificate)

None

Default/Recommen SSL ded Value

0~62

None

None

Equipment Planning AAU

60~254

None

None

Equipment Planning AAU

0 None

None

Equipment Planning AAU

0~31 characters

NULL

None

Equipment Planning AAU

MAAU

None

None

Equipment Planning AAU

LOCKED, UNLOCKED

UNLOCKED(Unlock UNLOCKED(Unlock Engineering Design AAU ed) ed)

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

AAU

Enabled, Disabled

None

None

N/A

AAU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

AAU

0~2047 characters

None

None

N/A

AAU

0~31 characters 0~31 characters

None None

None None

N/A N/A

AAU AAU

0~259 characters

None

None

N/A

AAU

0~11 characters

None

None

N/A

AAU

0~23 characters

None

None

N/A

AAU

0~19 characters

None

None

N/A

AAU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

AAU

0~4294967295 0~4294967295

None None

None None

N/A N/A

AAU AAU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

AAU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

AAU

None None

N/A N/A

AAU AAU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

AAU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

AAU

ON, OFF

ON(ON)

ON

Engineering Design AAU

1.5~10, step:0.1

30

None

Engineering Design AAU

1.5~3, step:0.1

20

None

Engineering Design AAU

0~7

None

None

Equipment Planning AAU

0~249

None

None

Equipment Planning AAU

TRUNK

TRUNK(TRUNK)

TRUNK

Equipment Planning AAU

TD_SCDMA, LTE_TDD, TDS_TDL, LTE_FDD, WiMAX_LTE, CDMA_LTE, GSM_LTE, UMTS_ONLY, UMTS_LTE

None

None

Equipment Planning AAU

0~8

None

None

Equipment Planning AAU

0~8

None

None

Equipment Planning AAU

0~4294967295

None

None

N/A

AAU

0~4294967295

None

None

N/A

AAU

0~429496729.5, step:0.1

None

None

N/A

AAU

0~429496729.5, step:0.1

None

None

N/A

AAU

0~429496729.5, step:0.1

None

None

N/A

AAU

0~429496729.5, step:0.1

None

None

N/A

AAU

0~50, step:0.1

None

None

N/A

AAU

0~6553.5, step:0.1

None

None

N/A

AAU

0~31

None

None

N/A

AAU

-100~200

None

None

N/A

AAU

-100~200

None

None

N/A

AAU

0~6

None

None

N/A

AAU

0~24 characters

None

None

N/A

AAU

LO_TD, TL, LO, WO, WL, C0, CL, CW, CWL, GO, GL, GW, GWL, GC, GCL, GCW, GCWL, UO, UL, UW, UWL, None UC, UCL, UCW, UCWL, GU, UGL, UGW, UGWL, UGC, UGCL, UGCW, UGCWL, NULL

None

N/A

AAU

CONNECTHEAD, CONNECTTAIL, CONNECTBOTH, None SEPERATEBYBRE AK, LINKDOWN

None

N/A

AAU

0~429496729.5, step:0.1

None

None

N/A

AAU

0~429496729.5, step:0.1

None

None

N/A

AAU

0~31

None

None

N/A

AAU

0~4294967295

None

None

N/A

AAU

ON, OFF

OFF(OFF)

ON(ON)

N/A

AAU

1~60

N/A

AAU

POW_IQ_MODE, POW_MODE, IQ_MODE

POW_IQ_MODE(P None OW_IQ_MODE)

N/A

AAU

9~18

None

None

N/A

AAU

HALFSECOND, ONESECOND, TWOSECOND, THREESECOND, FOURSECOND, FIVESECOND

HALFSECOND(HA None LFSECOND)

N/A

AAU

0~65535 0~31 characters

None NULL

None None

N/A N/A

AAU AAU

SUCCESS, FAILURE, UNKNOWTYPE

SUCCESS(SUCCE None SS)

N/A

AAU

USERDEFINE, DEFAULT

DEFAULT(DEFAUL None T)

N/A

AAU

0~1000000000

None

None

N/A

AAU

1.25G, 2.5G, 3.0G, None 4.9G, 6.1G, 9.8G

None

N/A

AAU

0~63 characters 0~63 characters

None None

None None

N/A N/A

AAU AAU

0~63 characters

None

None

N/A

AAU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

AAU AAU

None

None

N/A

AAU

0~65535

None

None

N/A

AAU

0~65535

None

None

N/A

AAU

LOCKED, UNLOCKED

UNLOCKED(Unlock UNLOCKED(Unlock Engineering Design RE ed) ed)

ON, OFF

ON(ON)

ON

Engineering Design RE

1.5~10, step:0.1

30

None

Engineering Design RE

1.5~3, step:0.1

20

None

Engineering Design RE

0~7

None

None

Equipment Planning RE

0~249

None

None

Equipment Planning RE

TRUNK

TRUNK(TRUNK)

TRUNK

Equipment Planning RE

TD_SCDMA, LTE_TDD, TDS_TDL, LTE_FDD, WiMAX_LTE, CDMA_LTE, GSM_LTE, UMTS_ONLY, UMTS_LTE

None

None

Equipment Planning RE

0~8

None

None

Equipment Planning RE

0~8

None

None

Equipment Planning RE

0~4294967295

None

None

N/A

RE

0~4294967295

None

None

N/A

RE

0~429496729.5, step:0.1

None

None

N/A

RE

0~429496729.5, step:0.1

None

None

N/A

RE

0~429496729.5, step:0.1

None

None

N/A

RE

0~429496729.5, step:0.1

None

None

N/A

RE

0~50, step:0.1

None

None

N/A

RE

0~6553.5, step:0.1

None

None

N/A

RE

0~31

None

None

N/A

RE

-100~200

None

None

N/A

RE

-100~200

None

None

N/A

RE

0~6

None

None

N/A

RE

0~24 characters

None

None

N/A

RE

LO_TD, TL, LO, WO, WL, C0, CL, CW, CWL, GO, GL, GW, GWL, GC, GCL, GCW, GCWL, UO, UL, UW, UWL, None UC, UCL, UCW, UCWL, GU, UGL, UGW, UGWL, UGC, UGCL, UGCW, UGCWL, NULL

None

N/A

RE

CONNECTHEAD, CONNECTTAIL, CONNECTBOTH, None SEPERATEBYBRE AK, LINKDOWN

None

N/A

RE

0~429496729.5, step:0.1

None

None

N/A

RE

0~429496729.5, step:0.1

None

None

N/A

RE

0~31

None

None

N/A

RE

0~4294967295

None

None

N/A

RE

ON, OFF

OFF(OFF)

ON(ON)

N/A

RE

1~60

N/A

RE

POW_IQ_MODE, POW_MODE, IQ_MODE

POW_IQ_MODE(P None OW_IQ_MODE)

N/A

RE

9~18

None

None

N/A

RE

HALFSECOND, ONESECOND, TWOSECOND, THREESECOND, FOURSECOND, FIVESECOND

HALFSECOND(HA None LFSECOND)

N/A

RE

0~65535 0~31 characters

None NULL

None None

N/A N/A

RE RE

SUCCESS, FAILURE, UNKNOWTYPE

SUCCESS(SUCCE None SS)

N/A

RE

USERDEFINE, DEFAULT

DEFAULT(DEFAUL None T)

N/A

RE

0~1000000000

None

None

N/A

RE

1.25G, 2.5G, 3.0G, None 4.9G, 6.1G, 9.8G

None

N/A

RE

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

RE

Enabled, Disabled

None

None

N/A

RE

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

RE

0~2047 characters

None

None

N/A

RE

0~31 characters 0~31 characters

None None

None None

N/A N/A

RE RE

0~259 characters

None

None

N/A

RE

0~11 characters

None

None

N/A

RE

0~23 characters

None

None

N/A

RE

0~19 characters

None

None

N/A

RE

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

RE

0~4294967295 0~4294967295

None None

None None

N/A N/A

RE RE

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

RE

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

RE

None None

N/A N/A

RE RE

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

RE

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

RE

0~63 characters 0~63 characters

None None

None None

N/A N/A

RE RE

0~63 characters

None

None

N/A

RE

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

RE RE

None

None

N/A

RE

0~65535

None

None

N/A

RE

0~65535

None

None

N/A

RE

0~62

None

Engineering Design RFU

4~5

None

None

Engineering Design RFU

0~8

None

None

Engineering Design RFU

MRFU, LRFU

None

None

Engineering Design RFU

LOCKED, UNLOCKED

UNLOCKED(Unlock UNLOCKED(Unlock Engineering Design RFU ed) ed)

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

RFU

Enabled, Disabled

None

None

N/A

RFU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

RFU

0~2047 characters

None

None

N/A

RFU

0~31 characters 0~31 characters

None None

None None

N/A N/A

RFU RFU

0~259 characters

None

None

N/A

RFU

0~11 characters

None

None

N/A

RFU

0~23 characters

None

None

N/A

RFU

0~19 characters

None

None

N/A

RFU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

RFU

0~4294967295 0~4294967295

None None

None None

N/A N/A

RFU RFU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

RFU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

RFU

None None

N/A N/A

RFU RFU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

RFU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

RFU

ON, OFF

ON(ON)

ON

Engineering Design RFU

1.5~10, step:0.1

30

None

Engineering Design RFU

1.5~3, step:0.1

20

None

Engineering Design RFU

0~7

None

None

Equipment Planning RFU

0~249

None

None

Equipment Planning RFU

TRUNK

TRUNK(TRUNK)

TRUNK

Equipment Planning RFU

TD_SCDMA, LTE_TDD, TDS_TDL, LTE_FDD, WiMAX_LTE, CDMA_LTE, GSM_LTE, UMTS_ONLY, UMTS_LTE

None

None

Equipment Planning RFU

0~8

None

None

Equipment Planning RFU

0~8

None

None

Equipment Planning RFU

0~4294967295

None

None

N/A

RFU

0~4294967295

None

None

N/A

RFU

0~429496729.5, step:0.1

None

None

N/A

RFU

0~429496729.5, step:0.1

None

None

N/A

RFU

0~429496729.5, step:0.1

None

None

N/A

RFU

0~429496729.5, step:0.1

None

None

N/A

RFU

0~50, step:0.1

None

None

N/A

RFU

0~6553.5, step:0.1

None

None

N/A

RFU

0~31

None

None

N/A

RFU

-100~200

None

None

N/A

RFU

-100~200

None

None

N/A

RFU

0~6

None

None

N/A

RFU

0~24 characters

None

None

N/A

RFU

LO_TD, TL, LO, WO, WL, C0, CL, CW, CWL, GO, GL, GW, GWL, GC, GCL, GCW, GCWL, UO, UL, UW, UWL, None UC, UCL, UCW, UCWL, GU, UGL, UGW, UGWL, UGC, UGCL, UGCW, UGCWL, NULL

None

N/A

RFU

CONNECTHEAD, CONNECTTAIL, CONNECTBOTH, None SEPERATEBYBRE AK, LINKDOWN

None

N/A

RFU

0~429496729.5, step:0.1

None

None

N/A

RFU

0~429496729.5, step:0.1

None

None

N/A

RFU

0~31

None

None

N/A

RFU

0~4294967295

None

None

N/A

RFU

ON, OFF

OFF(OFF)

ON(ON)

N/A

RFU

1~60

N/A

RFU

POW_IQ_MODE, POW_MODE, IQ_MODE

POW_IQ_MODE(P None OW_IQ_MODE)

N/A

RFU

9~18

None

None

N/A

RFU

HALFSECOND, ONESECOND, TWOSECOND, THREESECOND, FOURSECOND, FIVESECOND

HALFSECOND(HA None LFSECOND)

N/A

RFU

0~65535 0~31 characters

None NULL

None None

N/A N/A

RFU RFU

SUCCESS, FAILURE, UNKNOWTYPE

SUCCESS(SUCCE None SS)

N/A

RFU

USERDEFINE, DEFAULT

DEFAULT(DEFAUL None T)

N/A

RFU

0~1000000000

None

None

N/A

RFU

1.25G, 2.5G, 3.0G, None 4.9G, 6.1G, 9.8G

None

N/A

RFU

0~63 characters 0~63 characters

None None

None None

N/A N/A

RFU RFU

0~63 characters

None

None

N/A

RFU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

RFU RFU

None

None

N/A

RFU

0~65535

None

None

N/A

RFU

0~65535

None

None

N/A

RFU

00

None

Engineering Design RRU

60~254

None

None

Engineering Design RRU

00

None

Engineering Design RRU

0~31 characters

NULL

None

Engineering Design RRU

MRRU, PRRU, LRRU

None

None

Engineering Design RRU

PIMOFFLINE 120~300

None None

None None

N/A N/A

RRU RRU

5~20

None

None

N/A

RRU

0~1

None

None

N/A

RRU

IsInerefered, IsNotInterfered 0~4294967295 0~4294967295

None

None

N/A

RRU

None None

None None

N/A N/A

RRU RRU

0~4294967295

None

None

N/A

RRU

LOCKED, UNLOCKED

UNLOCKED(Unlock UNLOCKED(Unlock Engineering Design RRU ed) ed)

Alarm_0, Alarm_1, Alarm_2, Alarm_3, Alarm_4, Alarm_5, Alarm_6, Alarm_7, Alarm_8, Alarm_9, Alarm_10, Alarm_11, Alarm_12, Alarm_13, Alarm_14, Alarm_15

None

None

N/A

RRU

Enabled, Disabled

None

None

N/A

RRU

Avail_0, Avail_1, Avail_20, Avail_21, Avail_500, Avail_501, Avail_504, Avail_508, Avail_509, Avail_520, Avail_521, Avail_524, Avail_528, Avail_529, Avail_800, Avail_801, Avail_820, Avail_821, Avail_c10, None Avail_c11, Avail_c12, Avail_c13, Avail_c14, Avail_c30, Avail_c31, Avail_c32, Avail_c33, Avail_c34, Avail_d00, Avail_d01, Avail_d04, Avail_d08, Avail_d09, Avail_d20, Avail_d21, Avail_d24,

None

N/A

RRU

0~2047 characters

None

None

N/A

RRU

0~31 characters 0~31 characters

None None

None None

N/A N/A

RRU RRU

0~259 characters

None

None

N/A

RRU

0~11 characters

None

None

N/A

RRU

0~23 characters

None

None

N/A

RRU

0~19 characters

None

None

N/A

RRU

UMPT, FAN, UPEU, PMU, PSU, BAT, TCU, EMU, UTRP, USCU, UEIU, FMU, MRRU, MRFU, RHUB, UBRI, MRXU, MTXU, UCIU, CCU, MAAU, None UNKNOWN, PRRU, GRRU, GRFU, GATM, DRRU, DRFU, WRFU, NGRU, LMPT, LBBP, LRRU, LRFU, BRFU, CRFU, RRU

None

N/A

RRU

0~4294967295 0~4294967295

None None

None None

N/A N/A

RRU RRU

CPU, DSP, SLAVE_CPU, MDU_CPU, MRU_CPU

None

None

N/A

RRU

2147483648~21474 None 83647 2147483648~21474 None 83647 0~255 characters None

None

N/A

RRU

None None

N/A N/A

RRU RRU

Master, NDD, NCD, NDC, NEC, EUL, None EDL, Slave

None

N/A

RRU

CABINET, SUBRACK, BOARD, SUBBOARD, SFP

None

None

N/A

RRU

ON, OFF

ON(ON)

ON

Engineering Design RRU

1.5~10, step:0.1

30

None

Engineering Design RRU

1.5~3, step:0.1

20

None

Engineering Design RRU

0~7

None

None

Equipment Planning RRU

0~249

None

None

Equipment Planning RRU

TRUNK

TRUNK(TRUNK)

TRUNK

Equipment Planning RRU

TD_SCDMA, LTE_TDD, TDS_TDL, LTE_FDD, WiMAX_LTE, CDMA_LTE, GSM_LTE, UMTS_ONLY, UMTS_LTE

None

None

Equipment Planning RRU

0~8

None

None

Equipment Planning RRU

0~8

None

None

Equipment Planning RRU

0~4294967295

None

None

N/A

RRU

0~4294967295

None

None

N/A

RRU

0~429496729.5, step:0.1

None

None

N/A

RRU

0~429496729.5, step:0.1

None

None

N/A

RRU

0~429496729.5, step:0.1

None

None

N/A

RRU

0~429496729.5, step:0.1

None

None

N/A

RRU

0~50, step:0.1

None

None

N/A

RRU

0~6553.5, step:0.1

None

None

N/A

RRU

0~31

None

None

N/A

RRU

-100~200

None

None

N/A

RRU

-100~200

None

None

N/A

RRU

0~6

None

None

N/A

RRU

0~24 characters

None

None

N/A

RRU

LO_TD, TL, LO, WO, WL, C0, CL, CW, CWL, GO, GL, GW, GWL, GC, GCL, GCW, GCWL, UO, UL, UW, UWL, None UC, UCL, UCW, UCWL, GU, UGL, UGW, UGWL, UGC, UGCL, UGCW, UGCWL, NULL

None

N/A

RRU

CONNECTHEAD, CONNECTTAIL, CONNECTBOTH, None SEPERATEBYBRE AK, LINKDOWN

None

N/A

RRU

0~429496729.5, step:0.1

None

None

N/A

RRU

0~429496729.5, step:0.1

None

None

N/A

RRU

0~31

None

None

N/A

RRU

0~4294967295

None

None

N/A

RRU

ON, OFF

OFF(OFF)

ON(ON)

N/A

RRU

1~60

N/A

RRU

POW_IQ_MODE, POW_MODE, IQ_MODE

POW_IQ_MODE(P None OW_IQ_MODE)

N/A

RRU

9~18

None

None

N/A

RRU

HALFSECOND, ONESECOND, TWOSECOND, THREESECOND, FOURSECOND, FIVESECOND

HALFSECOND(HA None LFSECOND)

N/A

RRU

0~65535 0~31 characters

None NULL

None None

N/A N/A

RRU RRU

SUCCESS, FAILURE, UNKNOWTYPE

SUCCESS(SUCCE None SS)

N/A

RRU

USERDEFINE, DEFAULT

DEFAULT(DEFAUL None T)

N/A

RRU

0~1000000000

None

None

N/A

RRU

1.25G, 2.5G, 3.0G, None 4.9G, 6.1G, 9.8G

None

N/A

RRU

0~63 characters 0~63 characters

None None

None None

N/A N/A

RRU RRU

0~63 characters

None

None

N/A

RRU

0~63 characters 1~39 characters Normal, Fault, Timeout, NULL

None None

None None

N/A N/A

RRU RRU

None

None

N/A

RRU

0~65535

None

None

N/A

RRU

0~65535

None

None

N/A

RRU

0~249

None

None

Engineering Design RRUCHAIN

CHAIN, RING, LOADBALANCE

None

None

Engineering Design RRUCHAIN

COLD, HOT

COLD(COLD)

None

Engineering Design RRUCHAIN

0~7

None

Engineering Design RRUCHAIN

0~1

None

Engineering Design RRUCHAIN

0~5

None

None

Engineering Design RRUCHAIN

0~5

None

None

Engineering Design RRUCHAIN

0~7

None

Engineering Design RRUCHAIN

0~1

None

Engineering Design RRUCHAIN

0~5

None

None

Engineering Design RRUCHAIN

0~5

None

None

Engineering Design RRUCHAIN

0~8,255

255

None

Equipment Planning RRUCHAIN

0~8,255

255

None

Equipment Planning RRUCHAIN

LOCALPORT, PEERPORT

LOCALPORT(local None port)

Engineering Design RRUCHAIN

1.25G, 2.5G, 4.9G, AUTO(Auto) 6.1G, 9.8G, AUTO

None

Engineering Design RRUCHAIN

0~3

None

None

N/A

RRUCHAIN

0~3

None

None

N/A

RRUCHAIN

0~62

None

Engineering Design RxBranch

4~5,60~254

None

None

Engineering Design RxBranch

0~8

None

Engineering Design RxBranch

0~7

None

None

Engineering Design RxBranch

ON, OFF

ON(ON)

ON(ON)

Engineering Design RxBranch

0~22, step:0.5

None

Engineering Design RxBranch

ON, OFF

None

None

N/A

RxBranch

0~429496729.5, step:0.1

None

None

N/A

RxBranch

0~429496729.5, step:0.1

None

None

N/A

RxBranch

0~31

None

None

N/A

RxBranch

0~429496729.5, step:0.1

None

None

N/A

RxBranch

0~429496729.5, step:0.1

None

None

N/A

RxBranch

0~31

None

None

N/A

RxBranch

0~62

None

None

Engineering Design TxBranch

4~5,60~254

None

None

Engineering Design TxBranch

0~8

None

None

Engineering Design TxBranch

0~7

None

None

Engineering Design TxBranch

ON, OFF

ON(ON)

ON(ON)

Engineering Design TxBranch

1~25, step:0.01

None

None

N/A

TxBranch

ON, OFF

None

None

N/A

TxBranch

-10~1, step:0.1

None

N/A

TxBranch

0~13107, step:0.2

None

None

N/A

TxBranch

3~13, step:0.1

None

None

N/A

TxBranch

20~30 0~65535 0~65535

None None None

None None None

N/A N/A N/A

TxBranch TxBranch TxBranch

0~63 characters

None

None

N/A

TxBranch

0,5000~655000, step:10

None

None

N/A

TxBranch

0,5000~655000, step:10

None

None

N/A

TxBranch

0~429496729.5, step:0.1

None

None

N/A

TxBranch

0~429496729.5, step:0.1

None

None

N/A

TxBranch

0,5000~655000, step:10

None

None

N/A

TxBranch

0~429496729.5, step:0.1

None

None

N/A

TxBranch

0~429496729.5, step:0.1

None

None

N/A

TxBranch

0~31

None

None

N/A

TxBranch

0~429496729.5, step:0.1

None

None

N/A

TxBranch

0~429496729.5, step:0.1

None

None

N/A

TxBranch

0~31

None

None

N/A

TxBranch

0~6553.5, step:0.1

None

None

N/A

TxBranch

0~6553.5, step:0.1 Normal, Unknown, Crossed

None

None

N/A

TxBranch

None

None

N/A

TxBranch

Valid IP address

0.0.0.0

None

Equipment Planning NtpCp

1~525600

None

6 hours

Equipment Planning NtpCp

123~5999,6100~65 123 534

None

Equipment Planning NtpCp

IPV4, IPV6

IPV4(IPv4)

None

Default/Recommen NtpCp ded Value

Valid IP address

0:0:0:0:0:0:0:0

None

Equipment Planning NtpCp

PLAIN, DES_S, DES_N, DES_A, MD5

PLAIN(Plain)

None

Equipment Planning NtpCp

1~16 characters

None

None

Equipment Planning NtpCp

1~4294967295

None

None

Equipment Planning NtpCp

Slaver, Master

Slaver(Slave)

None

Engineering Design NtpCp

GMT-1200, GMT1100, GMT-1000, GMT-0930, GMT0900, GMT-0800, GMT-0700, GMT0600, GMT-0500, GMT-0430, GMT0400, GMT-0330, GMT-0300, GMT0200, GMT-0100, GMT, GMT+0100, GMT+0200, GMT+0300, GMT+0330, GMT+0400, GMT+0430, GMT+0500, GMT+0530, GMT+0545, GMT+0600, GMT+0630, GMT+0700, GMT+0800, GMT+0845, GMT+0900, GMT+0930, GMT+1000, GMT+1030, GMT+1100, GMT+1130, GMT+1200, GMT+1245, GMT+1300, GMT+1400, NO, YES

GMT+0800(GMT+0 None 8:00)

Equipment Planning TZ

NO(No)

None

Equipment Planning TZ

DATE, WEEK, DATEWEEK

DATE(Date mode)

None

Equipment Planning TZ

JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC

JAN(January)

None

Equipment Planning TZ

1~31

None

Equipment Planning TZ

LAST, FIRST, SECOND, THIRD, FOURTH

FIRST(First)

None

Equipment Planning TZ

MON, TUE, WED, THU, FRI, SAT, SUN

MON(Monday)

None

Equipment Planning TZ

00:00:00~23:59:59

00:00:00

None

Equipment Planning TZ

DATE, WEEK, DATEWEEK

DATE(Date mode)

None

Equipment Planning TZ

JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC

JAN(January)

None

Equipment Planning TZ

1~31

None

Equipment Planning TZ

LAST, FIRST, SECOND, THIRD, FOURTH

FIRST(First)

None

Equipment Planning TZ

MON, TUE, WED, THU, FRI, SAT, SUN

MON(Monday)

None

Equipment Planning TZ

00:00:00~23:59:59

00:00:00

None

Equipment Planning TZ

-120~120

None

Equipment Planning TZ

-720~840

None

Engineering Design TZ

2000-01-01~203312-31

None

None

N/A

OmuCurTime

00:00:00~23:59:59

None

None

N/A

OmuCurTime

None

None

None

N/A

OmuCurTime

NTP, GPS, NONE

NTP(NTP)

None

Equipment Planning TimeSrc

0~30 characters

None

None

N/A

TimeSrc

Valid IP address

127.0.0.1

None

Default/Recommen FTPCLTPORT ded Value

21~65535

21

None

Default/Recommen FTPCLTPORT ded Value

0~3

None

None

Radio Planning (Internal planning)

CnOperatorExtende dQci

10~254

None

None

Engineering Design

CnOperatorExtende dQci

0~9

None

Engineering Design

CnOperatorExtende dQci

0~9

None

Engineering Design

CnOperatorExtende dQci

0~3

None

None

Radio Planning (Internal planning)

CnOperatorStandar dQci

QCI1, QCI2, QCI3, QCI4, QCI5, QCI6, None QCI7, QCI8, QCI9

None

Engineering Design

CnOperatorStandar dQci

0~9

None

Engineering Design

CnOperatorStandar dQci

0~9

None

Engineering Design

CnOperatorStandar dQci

0~3

None

None

Engineering Design

CSFallBackBlindHo Cfg

UTRAN, GERAN, CDMA2000

UTRAN

UTRAN

Default/Recommen CSFallBackBlindHo ded Value Cfg

UTRAN, GERAN, CDMA2000, NULL

GERAN

GERAN

Default/Recommen CSFallBackBlindHo ded Value Cfg

UTRAN, GERAN, CDMA2000, NULL

CDMA2000

CDMA2000

Default/Recommen CSFallBackBlindHo ded Value Cfg

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CSFallBackBlindHo ded Value Cfg

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CSFallBackBlindHo ded Value Cfg

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CSFallBackBlindHo ded Value Cfg

0~3

None

None

Radio Planning (Internal planning)

InterPlmnHoList

000~999

None

None

Radio Planning (Negotiation with the peer)

InterPlmnHoList

00~99,000~999

None

None

Radio Planning (Negotiation with the peer)

InterPlmnHoList

0~255

None

None

Engineering Design

RatFreqPriorityGrou p

LTE, UTRAN, GERAN

None

None

Default/Recommen RatFreqPriorityGrou ded Value p

0~45589,64436~65 None 535

None

Radio Planning (Internal planning)

RatFreqPriorityGrou p

0~7

None

Radio Planning (Internal planning)

RatFreqPriorityGrou p

GSM_dcs1800, GSM_pcs1900

GSM_dcs1800

None

Engineering Design

RatFreqPriorityGrou p

0~3

None

None

Radio Planning (Internal planning)

ServiceIfHoCfgGrou p

0~9

None

None

Engineering Design

ServiceIfHoCfgGrou p

NO_HO, PERMIT_HO

NO_HO

None

Default/Recommen ServiceIfHoCfgGrou ded Value p

0~45589,64436~65 0 535

None

Radio Planning (Internal planning)

ServiceIfHoCfgGrou p

0~3

None

None

Radio Planning (Internal planning)

ServiceIrHoCfgGro up

0~9

None

None

Engineering Design

ServiceIrHoCfgGro up

NO_HO, PERMIT_HO, MUST_HO

NO_HO

None

Default/Recommen ServiceIrHoCfgGro ded Value up

1~256

None

None

Engineering Design SpidCfg

FALSE, TRUE

FALSE(FALSE)

None

Default/Recommen SpidCfg ded Value

NOT_CFG, CFG

NOT_CFG(NOT_C None FG)

Radio Planning (Internal planning)

SpidCfg

0~255

None

Radio Planning (Internal planning)

SpidCfg

FALSE, TRUE

TRUE(TRUE)

None

Default/Recommen SpidCfg ded Value

FALSE, TRUE

TRUE(TRUE)

None

Default/Recommen SpidCfg ded Value

FALSE, TRUE

TRUE(TRUE)

None

Default/Recommen SpidCfg ded Value

FALSE, TRUE

FALSE(FALSE)

None

Default/Recommen SpidCfg ded Value

0,10~600

Default/Recommen CounterCheckPara ded Value

0,128~4294967295 0

Default/Recommen CounterCheckPara ded Value

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design CounterCheckPara

NULL, Snow3G, AES

AES(AES Algorithm)

NULL(NULL Algorithm)

Engineering Design ENodeBCipherCap

NULL, Snow3G, AES

Snow3G(SNOW 3G AES(AES Algorithm) Algorithm)

Engineering Design ENodeBCipherCap

NULL, Snow3G, AES

NULL(NULL Algorithm)

Snow3G(SNOW 3G Engineering Design ENodeBCipherCap Algorithm)

10~200

20

20

Default/Recommen ENodeBConnState ded Value Timer

10~200

20

20

Default/Recommen ENodeBConnState ded Value Timer

10~200

35

35

Default/Recommen ENodeBConnState ded Value Timer

NULL, Snow3G, AES

AES(AES Algorithm)

AES(AES Algorithm)

Engineering Design

ENodeBIntegrityCa p

NULL, Snow3G, AES

Snow3G(SNOW 3G Snow3G(Snow 3G Algorithm) Algorithm)

Engineering Design

ENodeBIntegrityCa p

NULL, Snow3G, AES

NULL(NULL Algorithm)

NULL(NULL Algorithm)

Engineering Design

ENodeBIntegrityCa p

OFF, ON

ON(On)

ON(On)

Engineering Design GlobalProcSwitch

X2_OVER_M2000( X2_OVER_M2000( X2_OVER_M2000, X2SonLink is set up X2SonLink is set up Engineering Design GlobalProcSwitch X2_OVER_S1 over M2000) over M2000)

OFF, ON

ON(On)

ON(On)

Engineering Design GlobalProcSwitch

LCG_PROFILE_0, LCG_PROFILE_1

LCG_PROFILE_0

LCG_PROFILE_0

Engineering Design GlobalProcSwitch

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design GlobalProcSwitch

OFF, ON

ON(On)

ON(On)

Engineering Design GlobalProcSwitch

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design GlobalProcSwitch

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design PdcpRohcPara

U_MODE, O_MODE, R_MODE

U_MODE(Unidirecti U_MODE(Unidirecti Engineering Design PdcpRohcPara onal Mode) onal Mode)

Profile0x0001, Profile0x0002, Profile0x0003, Profile0x0004

Profile0x0001:on, Profile0x0002:on, Profile0x0003:on, Profile0x0004:on

Profile0x0001: on; Profile0x0002: on; Profile0x0003: on; Profile0x0004: on

Engineering Design PdcpRohcPara

1~16

Default/Recommen RrcConnStateTimer ded Value

min5, min10, min20, min30, min60, min10(10) min120, min180

min10(10)

Default/Recommen RrcConnStateTimer ded Value

ms50, ms100, ms150, ms200, ms500, ms1000, ms2000

ms500(500)

ms500(500)

Default/Recommen RrcConnStateTimer ded Value

ms100, ms200, ms500, ms1000, ms2000, ms4000, ms8000

ms8000(8000)

ms8000(8000)

Default/Recommen RrcConnStateTimer ded Value

min5, min10, min20, min30, min60, min120(120) min120, min180

min120(120)

Default/Recommen RrcConnStateTimer ded Value

0~3600

20

20

Default/Recommen RrcConnStateTimer ded Value

0~3600

180

180

Default/Recommen RrcConnStateTimer ded Value

0~255

None

None

N/A

TceIpMapping

IPv4, IPv6

IPv4(IPv4 Address) None

N/A

TceIpMapping

Valid IP address

0.0.0.0

None

N/A

TceIpMapping

Valid IP address

0:0:0:0:0:0:0:0

None

N/A

TceIpMapping

0~17

None

None

Radio Planning (Internal planning)

CellDlpcPdschPa

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CellDlpcPdschPa ded Value

DB_6_P_A, DB_4DOT77_P_A, DB_3_P_A, DB_1DOT77_P_A, DB_3_P_A(-3 dB) DB0_P_A, DB1_P_A, DB2_P_A, DB3_P_A

Dual-antenna or four-antenna: DB_3_P_A(-3 dB) Single-antenna: DB0_P_A(0 dB)

Default/Recommen CellDlpcPdschPa ded Value

0~17

None

None

Radio Planning (Internal planning)

CellDrxPara

0~999

300

300

Default/Recommen CellDrxPara ded Value

1~1000

800

800

Default/Recommen CellDrxPara ded Value

0~1999

300

300

Default/Recommen CellDrxPara ded Value

1~2000

800

800

Default/Recommen CellDrxPara ded Value

0~1999

300

300

Default/Recommen CellDrxPara ded Value

1~2000

800

800

Default/Recommen CellDrxPara ded Value

40~6000, step:20

30

30

Default/Recommen CellDrxPara ded Value

0~17

None

None

Radio Planning (Internal planning)

CellUlpcDedic

UU_DISABLE, UU_ENABLE

UU_DISABLE(Disa UU_DISABLE(Disa Default/Recommen CellUlpcDedic ble) ble) ded Value

-10.5~12, step:1.5

-30

-30

Default/Recommen CellUlpcDedic ded Value

-3~12

-30

-30

Default/Recommen CellUlpcDedic ded Value

UU_FC0_FILTER_ COEFF, UU_FC1_FILTER_ COEFF, UU_FC2_FILTER_ COEFF, UU_FC3_FILTER_ COEFF, UU_FC4_FILTER_ COEFF, UU_FC5_FILTER_ COEFF, UU_FC6_FILTER_ COEFF, UU_FC6_FILTER_ UU_FC6_FILTER_ UU_FC7_FILTER_ Default/Recommen COEFF(UU_FC6_F COEFF(UU_FC6_F CellUlpcDedic COEFF, ded Value ILTER_COEFF) ILTER_COEFF) UU_FC8_FILTER_ COEFF, UU_FC9_FILTER_ COEFF, UU_FC11_FILTER_ COEFF, UU_FC13_FILTER_ COEFF, UU_FC15_FILTER_ COEFF, UU_FC17_FILTER_ COEFF, UU_FC19_FILTER_ COEFF

0~17

None

None

Engineering Design DistBasedHO

EUTRAN:On, EUTRAN, GERAN, GERAN:Off, UTRAN UTRAN:Off

EUTRAN:On, GERAN:Off, UTRAN:Off

Engineering Design DistBasedHO

100~100000

10

10

Engineering Design DistBasedHO

0~17

None

None

Radio Planning (Internal planning)

DrxParaGroup

0~9

None

None

Engineering Design DrxParaGroup

OFF, ON

OFF(Off)

QCI 1: ON(On) QCI 2: OFF(Off) QCI 3: OFF(Off) QCI 4: ON(On) QCI 5: OFF(Off) QCI 6: ON(On) QCI 7: OFF(Off) QCI 8: ON(On) QCI 9: ON(On)

Engineering Design DrxParaGroup

QCI 1-FDD: PSF10(10 subframes) QCI 1-TDDConfiguration 0: PSF4(4 subframes) QCI 1-TDDConfiguration 1: PSF6(6 subframes) QCI 1-TDDConfiguration 2: PSF8(8 subframes) QCI 1-TDDConfiguration 3: PSF1, PSF2, PSF3, PSF6(6 subframes) PSF4, PSF5, PSF6, QCI 1-TDDPSF8, PSF10, Configuration 4: PSF20, PSF30, PSF2(2 subframes) Engineering Design DrxParaGroup PSF8(8 subframes) PSF40, PSF50, QCI 1-TDDPSF60, PSF80, Configuration 5: PSF100, PSF200 PSF8(8 subframes) QCI 1-TDDConfiguration 6: PSF5(5 subframes) QCI 4-FDD: PSF2(2 subframes) QCI 4-TDDConfiguration 0: PSF2(2 subframes) QCI 4-TDDConfiguration 1: PSF2(2 subframes) QCI 4-TDDConfiguration 2:

PSF1, PSF2, PSF3, PSF4, PSF5, PSF6, PSF8, PSF10, PSF20, PSF30, PSF40, PSF50, PSF60, PSF80, PSF100, PSF200, PSF300, PSF500, PSF750, PSF1280, PSF1920, PSF2560

QCI 1-FDD: PSF3(3 subframes) QCI 1-TDDConfiguration 0: PSF3(3 subframes) QCI 1-TDDConfiguration 1: PSF3(3 subframes) QCI 1-TDDConfiguration 2: PSF5(5 subframes) QCI 1-TDDConfiguration 3: PSF6(6 subframes) QCI 1-TDDConfiguration 4: PSF8(8 subframes) PSF3(3 subframes) Engineering Design DrxParaGroup QCI 1-TDDConfiguration 5: PSF10(10 subframes) QCI 1-TDDConfiguration 6: PSF3(3 subframes) QCI 4-FDD: PSF4(4 subframes) QCI 4-TDDConfiguration 0: PSF4(4 subframes) QCI 4-TDDConfiguration 1: PSF4(4 subframes) QCI 4-TDDConfiguration 2:

sf1, sf2, sf4, sf6, sf8(8 subframes) sf8, sf16, sf24, sf33

QCI 1: sf8(8 subframes) QCI 4: sf8(8 subframes) QCI 6: sf8(8 subframes) QCI 8: sf8(8 subframes) QCI 9: sf8(8 subframes)

Engineering Design DrxParaGroup

SF10, SF20, SF32, SF40, SF64, SF80, SF128, SF160, SF40(40 SF256, SF320, subframes) SF512, SF640, SF1024, SF1280, SF2048, SF2560

QCI 1: SF20(20 subframes) QCI 4: SF20(20 subframes) QCI 6: SF40(40 subframes) QCI 8: SF40(40 subframes) QCI 9: SF40(40 subframes)

Engineering Design DrxParaGroup

UU_DISABLE, UU_ENABLE

QCI 1: UU_DISABLE(Disa ble) QCI 4: UU_ENABLE(Enabl e) QCI 6: UU_ENABLE(Enabl UU_ENABLE(Enabl Engineering Design DrxParaGroup e) e) QCI 8: UU_ENABLE(Enabl e) QCI 9: UU_ENABLE(Enabl e)

SF2, SF5, SF8, SF10, SF16, SF20, SF32, SF40, SF64, SF80, SF128, SF5(5 subframes) SF160, SF256, SF320, SF512, SF640

QCI 4: SF5(5 subframes) QCI 6: SF5(5 subframes) QCI 8: SF5(5 subframes) QCI 9: SF5(5 subframes)

Engineering Design DrxParaGroup

1~16

QCI 4: 2 QCI 6: 8 QCI 8: 8 QCI 9: 8

Engineering Design DrxParaGroup

0~17

None

None

Engineering Design

InterRatHoCommGr oup

0~9

None

None

Engineering Design

InterRatHoCommGr oup

0~15, step:0.5

None

Default/Recommen InterRatHoCommGr ded Value oup

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

None

Default/Recommen InterRatHoCommGr ded Value oup

-141~-43

-111

None

Default/Recommen InterRatHoCommGr ded Value oup

-20~-3, step:0.5

-20

None

Default/Recommen InterRatHoCommGr ded Value oup

-141~-43

-115

None

Default/Recommen InterRatHoCommGr ded Value oup

-20~-3, step:0.5

-24

None

Default/Recommen InterRatHoCommGr ded Value oup

0~15

None

Default/Recommen InterRatHoCommGr ded Value oup

0~17

None

None

Engineering Design

InterRatHoCdma1x RttGroup

0~9

None

None

Engineering Design

InterRatHoCdma1x RttGroup

0~15, step:0.5

Default/Recommen InterRatHoCdma1x ded Value RttGroup

-31.5~0, step:0.5

-28

-28

Default/Recommen InterRatHoCdma1x ded Value RttGroup

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

640ms

Default/Recommen InterRatHoCdma1x ded Value RttGroup

-31.5~0, step:0.5

-24

-24

Default/Recommen InterRatHoCdma1x ded Value RttGroup

10~254

None

None

Engineering Design CellExtendedQci

0~17

None

None

Engineering Design CellExtendedQci

0~9

None

Default/Recommen CellExtendedQci ded Value

0~9

None

Default/Recommen CellExtendedQci ded Value

0~9

None

Default/Recommen CellExtendedQci ded Value

0~9

None

Default/Recommen CellExtendedQci ded Value

0~9

None

Default/Recommen CellExtendedQci ded Value

0~9

None

Default/Recommen CellExtendedQci ded Value

0~9

None

Engineering Design CellExtendedQci

0~9

None

Engineering Design CellExtendedQci

0~17

None

None

Radio Planning (Internal planning)

CellStandardQci

QCI1, QCI2, QCI3, QCI4, QCI5, QCI6, None QCI7, QCI8, QCI9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

0~9

None

Engineering Design CellStandardQci

ms5, ms10, ms20, ms40, ms80

ms10(SRI 10ms)

ms10(SRI 10ms)

Engineering Design CellStandardQci

0~17

None

None

Engineering Design

InterRatHoCdmaHr pdGroup

0~9

None

None

Engineering Design

InterRatHoCdmaHr pdGroup

0~15, step:0.5

Default/Recommen InterRatHoCdmaHr ded Value pdGroup

-31.5~0, step:0.5

-14

-14

Default/Recommen InterRatHoCdmaHr ded Value pdGroup

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

640ms

Default/Recommen InterRatHoCdmaHr ded Value pdGroup

-31.5~0, step:0.5

-10

-10

Default/Recommen InterRatHoCdmaHr ded Value pdGroup

0~17

None

None

Engineering Design

InterRatHoGeranGr oup

0~9

None

None

Engineering Design

InterRatHoGeranGr oup

0~15, step:0.5

None

Default/Recommen InterRatHoGeranGr ded Value oup

-110~-48

-100

None

Default/Recommen InterRatHoGeranGr ded Value oup

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

640ms

Default/Recommen InterRatHoGeranGr ded Value oup

-110~-48

-98

None

Default/Recommen InterRatHoGeranGr ded Value oup

0~17

None

None

Engineering Design

InterRatHoUtranGro up

0~9

None

None

Engineering Design

InterRatHoUtranGro up

-24~0, step:0.5

-20

None

Default/Recommen InterRatHoUtranGro ded Value up

-120~-25

-103

None

Default/Recommen InterRatHoUtranGro ded Value up

0~15, step:0.5

None

Default/Recommen InterRatHoUtranGro ded Value up

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

None

Default/Recommen InterRatHoUtranGro ded Value up

-24~0, step:0.5

-18

None

Default/Recommen InterRatHoUtranGro ded Value up

-120~-25

-101

None

Default/Recommen InterRatHoUtranGro ded Value up

0~17

None

None

Engineering Design InterFreqHoGroup

0~9

None

None

Engineering Design InterFreqHoGroup

0~15, step:0.5

Default/Recommen InterFreqHoGroup ded Value

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

None

Default/Recommen InterFreqHoGroup ded Value

-141~-43

-105

None

Default/Recommen InterFreqHoGroup ded Value

-20~-3, step:0.5

-20

None

Default/Recommen InterFreqHoGroup ded Value

-141~-43

-109

None

Default/Recommen InterFreqHoGroup ded Value

-20~-3, step:0.5

-24

None

Default/Recommen InterFreqHoGroup ded Value

0~15, step:0.5

Default/Recommen InterFreqHoGroup ded Value

-141~-43

-105

None

Default/Recommen InterFreqHoGroup ded Value

-20~-3, step:0.5

-20

None

Default/Recommen InterFreqHoGroup ded Value

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

None

Default/Recommen InterFreqHoGroup ded Value

-141~-43

-103

-103

Default/Recommen InterFreqHoGroup ded Value

-20~-3, step:0.5

-18

-18

Default/Recommen InterFreqHoGroup ded Value

-141~-43

-85

-85

Default/Recommen InterFreqHoGroup ded Value

-20~-3, step:0.5

-16

-16

Default/Recommen InterFreqHoGroup ded Value

-15~15, step:0.5

Default/Recommen InterFreqHoGroup ded Value

-141~-44

-95

-95

Default/Recommen InterFreqHoGroup ded Value

-141~-44

-99

-99

Default/Recommen InterFreqHoGroup ded Value

-140~-43

-87

-87

Default/Recommen InterFreqHoGroup ded Value

-20~-3, step:0.5

-20

-20

Default/Recommen InterFreqHoGroup ded Value

0~17

None

None

Engineering Design IntraFreqHoGroup

0~9

None

None

Engineering Design IntraFreqHoGroup

0~15, step:0.5

Default/Recommen IntraFreqHoGroup ded Value

-15~15, step:0.5

Default/Recommen IntraFreqHoGroup ded Value

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

320ms

320ms

Default/Recommen IntraFreqHoGroup ded Value

0~3

None

None

Radio Planning (Internal planning)

CnOperator

1~32 characters

None

None

N/A

CnOperator

CNOPERATOR_P RIMARY, None CNOPERATOR_SE CONDARY

None

Radio Planning (Internal planning)

CnOperator

000~999

None

None

Radio Planning (Internal planning)

CnOperator

00~99,000~999

None

None

Radio Planning (Internal planning)

CnOperator

0~65535

None

None

Radio Planning (Internal planning)

CnOperatorIpPath

0~3

None

None

Radio Planning (Internal planning)

CnOperatorIpPath

0~65535

None

None

Radio Planning (Internal planning)

CnOperatorTa

0~3

None

None

Radio Planning (Internal planning)

CnOperatorTa

0~65535

None

None

Radio Planning (Internal planning)

CnOperatorTa

0~3

None

None

Radio Planning (Internal planning)

Emc

OFF, ON

OFF(Off)

None

Engineering Design Emc

OFF, ON

OFF(Off)

None

Engineering Design Emc

1~15

Engineering Design Emc

1~15

Engineering Design Emc

INDEPENDENT, INDEPENDENT(Ind SHARED_FREQ, ependent Operator None SEPARATED_FRE Mode) Q

Radio Planning (Internal planning)

ENodeBSharingMo de

0~3

None

None

Radio Planning (Internal planning)

LicenseSharingPoli cy

1~100

None

None

Engineering Design

LicenseSharingPoli cy

1~300

None

Engineering Design S1ReestTimer

1~300

300

None

Engineering Design S1ReestTimer

0~15

None

None

Radio Planning (Internal planning)

S1Interface

0~79

None

None

Radio Planning (Internal planning)

S1Interface

0~3

None

None

Radio Planning (Internal planning)

S1Interface

Release_R8, Release_R9, Release_R10

Release_R8(Releas None e 8)

Radio Planning (Negotiation with the peer)

S1Interface

FALSE, TRUE

FALSE(FALSE)

None

N/A

S1Interface

Normal, Abnormal Normal, Abnormal, Blocked FALSE, TRUE, NULL

None

None

N/A

S1Interface

None

None

N/A

S1Interface

None

None

N/A

S1Interface

0~3600

None

None

N/A

S1Interface

0~150 characters

None

None

N/A

S1Interface

0~224 characters

None

None

N/A

S1Interface

0~300 characters

None

None

N/A

S1Interface

0~255

None

None

N/A

S1Interface

Null, LowerLinkFault, MmecImpact, SetupFail, CfgErr, LicRestrict, PlmnDiff, TacNotCfg, Undefine

None

None

N/A

S1Interface

0~15

None

None

Radio Planning (Internal planning)

MmeFeatureCfg

DISABLE, ENABLE DISABLE(disable)

None

Engineering Design MmeFeatureCfg

000~999

None

None

Engineering Design X2BlackWhiteList

00~99,000~999

None

None

Engineering Design X2BlackWhiteList

0~1048575

None

None

Engineering Design X2BlackWhiteList

X2_BLACK_LIST_T YPE, X2_BLACK_LIST_T None X2_WHITE_LIST_T YPE YPE

Radio Planning (Internal planning)

X2BlackWhiteList

16~79

None

None

Radio Planning (Internal planning)

X2Interface

0~79

None

None

Radio Planning (Internal planning)

X2Interface

0~3

None

None

Radio Planning (Internal planning)

X2Interface

Release_R8, Release_R9, Release_R10

Release_R10(Relea None se 10)

Radio Planning (Internal planning)

X2Interface

FORBID_AUTO_R FORBID_AUTO_R FORBID_AUTO_R MV, Radio Planning MV(Forbid Auto MV(Forbid Auto PERMIT_AUTO_R (Internal planning) Remove) Remove) MV

X2Interface

0~50 characters

None

None

N/A

X2Interface

0~50 characters

None

None

N/A

X2Interface

Normal, Abnormal

None

None

N/A

X2Interface

SCTP_LINK_FAUL T, SETUP_FAILURE_ OCCUR, PEERIN_BLACK_LI None ST, STATE_NORMAL, SETUP_ONLY_ON E_LINK_ALLOWED

None

N/A

X2Interface

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design Drx

OFF, ON

ON(On)

ON(On)

Default/Recommen Drx ded Value

SF10, SF20, SF32, SF40, SF64, SF80, SF128, SF160, SF10(10 SF256, SF320, subframes) SF512, SF640, SF1024, SF1280, SF2048, SF2560

SF10(10 subframes)

Default/Recommen Drx ded Value

PSF1, PSF2, PSF3, PSF4, PSF5, PSF6, PSF8, PSF10, Default/Recommen PSF20, PSF30, PSF4(4 subframes) PSF4(4 subframes) Drx ded Value PSF40, PSF50, PSF60, PSF80, PSF100, PSF200

PSF1, PSF2, PSF3, PSF4, PSF5, PSF6, PSF8, PSF10, PSF20, PSF30, PSF40, PSF50, PSF60, PSF80, PSF100, PSF200, PSF300, PSF500, PSF750, PSF1280, PSF1920, PSF2560

PSF5(5 subframes) for FDD PSF3(3 subframes) for TDD in subframe configuration 0 PSF3(3 subframes) for TDD in subframe configuration 1 PSF4(4 subframes) for TDD in subframe configuration 2 PSF3(3 subframes) Default/Recommen PSF5(5 subframes) Drx for TDD in ded Value subframe configuration 3 PSF4(4 subframes) for TDD in subframe configuration 4 PSF4(4 subframes) for TDD in subframe configuration 5 PSF3(3 subframes) for TDD in subframe configuration 6

UU_DISABLE, UU_ENABLE

UU_DISABLE(Disa UU_DISABLE(Disa Default/Recommen Drx ble) ble) ded Value

SF2, SF5, SF8, SF10, SF16, SF20, SF32, SF40, SF64, SF10(10 SF80, SF128, subframes) SF160, SF256, SF320, SF512, SF640

SF10(10 subframes)

Default/Recommen Drx ded Value

1~16

Default/Recommen Drx ded Value

SF128, SF160, SF256, SF320, SF512, SF640, SF1024, SF1280, SF2048, SF2560

SF320(320 subframes)

SF320(320 subframes)

Default/Recommen Drx ded Value

SF128, SF160, SF256, SF320, SF512, SF640, SF1024, SF1280, SF2048, SF2560

SF1280(1280 subframes)

SF1280(1280 subframes)

Default/Recommen Drx ded Value

10~254

None

None

Engineering Design ExtendedQci

IMS signaling: IMSSignalling(IMS Signalling) Low-delay service: IMSSignalling, LowDelay(Low TCPorBuffStreamin LowDelay, Delay) g(TCP Based or Engineering Design ExtendedQci TCPorBuffStreamin TCP service or nonBuffered Streaming) g real-time streaming service: TCPorBuffStreamin g(TCP Based or Buffered Streaming)

0.001~1, step:0.001 700

IMS signaling: 1000 Low-delay service: 900 Engineering Design ExtendedQci TCP service or nonreal-time streaming service: 700 IMS signaling: 1000 Low-delay service: 900 Engineering Design ExtendedQci TCP service or nonreal-time streaming service: 700

0.001~1, step:0.001 700

MinGbrRate_0_KB, MinGbrRate_1_KB, MinGbrRate_2_KB, MinGbrRate_4KB, MinGbrRate_8_KB, MinGbrRate_16_KB , MinGbrRate_32_KB MinGbrRate_1_KB( MinGbrRate_1_KB( , Engineering Design ExtendedQci 1KB/s) 1KB/s) MinGbrRate_64_KB , MinGbrRate_128_K B, MinGbrRate_256_K B, MinGbrRate_512_K B

MinGbrRate_0_KB, MinGbrRate_1_KB, MinGbrRate_2_KB, MinGbrRate_4KB, MinGbrRate_8_KB, MinGbrRate_16_KB , MinGbrRate_32_KB MinGbrRate_1_KB( MinGbrRate_1_KB( , Engineering Design ExtendedQci 1KB/s) 1KB/s) MinGbrRate_64_KB , MinGbrRate_128_K B, MinGbrRate_256_K B, MinGbrRate_512_K B

0~1, step:0.1

10

10

Engineering Design ExtendedQci

0~39

None

Engineering Design ExtendedQci

PBR_0_KBps, PBR_8_KBps, PBR_16_KBps, PBR_32_KBps, PBR_64_KBps, PBR_128_KBps, PBR_256_KBps, PBR_INFINITY

PBR_8_KBps(8KB/ PBR_8_KBps(8KB/ Engineering Design ExtendedQci s) s)

9~16

11

11

Engineering Design ExtendedQci

0~39

None

Engineering Design ExtendedQci

PAID_USER, FREE_USER

PAID_USER(Paid User)

PAID_USER(Paid User)

Engineering Design ExtendedQci

FLOW_CTRL, FLOW_CTRL(Flow None NON_FLOW_CTRL Control)

Engineering Design ExtendedQci

0~39

None

None

Engineering Design

InterRatPolicyCfgGr oup

PS_HO, SRVCC, REDIRECTION

PS_HO:On, SRVCC:Off, None REDIRECTION:Off

Default/Recommen InterRatPolicyCfgGr ded Value oup

SRVCC

SRVCC:On

None

Default/Recommen InterRatPolicyCfgGr ded Value oup

PS_HO:On, PS_HO, NACC_HO:Off, NACC_HO, CCO_HO:Off, None CCO_HO, SRVCC, SRVCC:Off, REDIRECTION REDIRECTION:Off

Default/Recommen InterRatPolicyCfgGr ded Value oup

SRVCC

CDMA1XRTTHoSwi None tch:On

Default/Recommen InterRatPolicyCfgGr ded Value oup

OPT_HO, NON_OPT_HO

OPT_HO:On, None NON_OPT_HO:Off

Default/Recommen InterRatPolicyCfgGr ded Value oup

PERMIT_HO_ENU M, PERMIT_HO_ENU None FORBID_HO_ENU M(Permit Ho) M

Default/Recommen InterRatPolicyCfgGr ded Value oup

PERMIT_FAST_AN R_MEAS_ENUM, PERMIT_FAST_AN None FORBID_FAST_AN R_MEAS_ENUM R_MEAS_ENUM

Default/Recommen InterRatPolicyCfgGr ded Value oup

0~15

12

None

Default/Recommen PuschParam ded Value

0~15

None

Default/Recommen PuschParam ded Value

0~15

None

Default/Recommen PuschParam ded Value

0~39

None

None

Engineering Design RlcPdcpParaGroup

DiscardTimer_50, DiscardTimer_100, DiscardTimer_150, DiscardTimer_300, DiscardTimer_1500 DiscardTimer_500, None (1500 ms) DiscardTimer_750, DiscardTimer_1500, DiscardTimer_Infinit y

Default/Recommen RlcPdcpParaGroup ded Value

RlcMode_AM, RlcMode_UM

RlcMode_AM(Ackn None owledge Mode)

Default/Recommen RlcPdcpParaGroup ded Value

Maxretx_Threshold _t1, Maxretx_Threshold _t2, Maxretx_Threshold _t3, Maxretx_Threshold _t4, Maxretx_Threshold None Maxretx_Threshold _t8(8) _t6, Maxretx_Threshold _t8, Maxretx_Threshold _t16, Maxretx_Threshold _t32

Default/Recommen RlcPdcpParaGroup ded Value

Maxretx_Threshold _t1, Maxretx_Threshold _t2, Maxretx_Threshold _t3, Maxretx_Threshold _t4, Maxretx_Threshold None Maxretx_Threshold _t8(8) _t6, Maxretx_Threshold _t8, Maxretx_Threshold _t16, Maxretx_Threshold _t32

Default/Recommen RlcPdcpParaGroup ded Value

PollByte_kb25, PollByte_kb50, PollByte_kb75, PollByte_kb100, PollByte_kb125, PollByte_kb250, PollByte_kb375, PollByte_kb500, PollByte_kb750, PollByte_kb1000, PollByte_kb1250, PollByte_kb1500, PollByte_kb2000, PollByte_kb3000, PollByte_infinity

PollByte_kb25(25 kBytes)

None

Default/Recommen RlcPdcpParaGroup ded Value

PollByte_kb25, PollByte_kb50, PollByte_kb75, PollByte_kb100, PollByte_kb125, PollByte_kb250, PollByte_kb375, PollByte_kb500, PollByte_kb750, PollByte_kb1000, PollByte_kb1250, PollByte_kb1500, PollByte_kb2000, PollByte_kb3000, PollByte_infinity

PollByte_kb25(25 kBytes)

None

Default/Recommen RlcPdcpParaGroup ded Value

PollPdu_p4, PollPdu_p8, PollPdu_p16, PollPdu_p32, PollPdu_p64, PollPdu_p128, PollPdu_p256, PollPdu_Infinity

PollPdu_p32(32 PDUs)

None

Default/Recommen RlcPdcpParaGroup ded Value

PollPdu_p4, PollPdu_p8, PollPdu_p16, PollPdu_p32, PollPdu_p64, PollPdu_p128, PollPdu_p256, PollPdu_Infinity

PollPdu_p32(32 PDUs)

None

Default/Recommen RlcPdcpParaGroup ded Value

Tpollretrans_m5, Tpollretrans_m10, Tpollretrans_m15, Tpollretrans_m20, Tpollretrans_m25, Tpollretrans_m30, Tpollretrans_m35, Tpollretrans_m40, Tpollretrans_m45, Tpollretrans_m50, Tpollretrans_m55, Tpollretrans_m60, Tpollretrans_m65, Tpollretrans_m70, Tpollretrans_m75, Tpollretrans_m80, Tpollretrans_m85, Tpollretrans_m40(4 None Tpollretrans_m90, 0ms) Tpollretrans_m95, Tpollretrans_m100, Tpollretrans_m105, Tpollretrans_m110, Tpollretrans_m115, Tpollretrans_m120, Tpollretrans_m125, Tpollretrans_m130, Tpollretrans_m135, Tpollretrans_m140, Tpollretrans_m145, Tpollretrans_m150, Tpollretrans_m155, Tpollretrans_m160, Tpollretrans_m165, Tpollretrans_m170,

Default/Recommen RlcPdcpParaGroup ded Value

Tpollretrans_m5, Tpollretrans_m10, Tpollretrans_m15, Tpollretrans_m20, Tpollretrans_m25, Tpollretrans_m30, Tpollretrans_m35, Tpollretrans_m40, Tpollretrans_m45, Tpollretrans_m50, Tpollretrans_m55, Tpollretrans_m60, Tpollretrans_m65, Tpollretrans_m70, Tpollretrans_m75, Tpollretrans_m80, Tpollretrans_m85, Tpollretrans_m50(5 None Tpollretrans_m90, 0ms) Tpollretrans_m95, Tpollretrans_m100, Tpollretrans_m105, Tpollretrans_m110, Tpollretrans_m115, Tpollretrans_m120, Tpollretrans_m125, Tpollretrans_m130, Tpollretrans_m135, Tpollretrans_m140, Tpollretrans_m145, Tpollretrans_m150, Tpollretrans_m155, Tpollretrans_m160, Tpollretrans_m165, Tpollretrans_m170,

Default/Recommen RlcPdcpParaGroup ded Value

Tstatprohibit_m0, Tstatprohibit_m5, Tstatprohibit_m10, Tstatprohibit_m15, Tstatprohibit_m20, Tstatprohibit_m25, Tstatprohibit_m30, Tstatprohibit_m35, Tstatprohibit_m40, Tstatprohibit_m45, Tstatprohibit_m50, Tstatprohibit_m55, Tstatprohibit_m60, Tstatprohibit_m65, Tstatprohibit_m70, Tstatprohibit_m75, Tstatprohibit_m80, Tstatprohibit_m50(5 None Tstatprohibit_m85, 0ms) Tstatprohibit_m90, Tstatprohibit_m95, Tstatprohibit_m100, Tstatprohibit_m105, Tstatprohibit_m110, Tstatprohibit_m115, Tstatprohibit_m120, Tstatprohibit_m125, Tstatprohibit_m130, Tstatprohibit_m135, Tstatprohibit_m140, Tstatprohibit_m145, Tstatprohibit_m150, Tstatprohibit_m155, Tstatprohibit_m160, Tstatprohibit_m165,

Default/Recommen RlcPdcpParaGroup ded Value

Tstatprohibit_m0, Tstatprohibit_m5, Tstatprohibit_m10, Tstatprohibit_m15, Tstatprohibit_m20, Tstatprohibit_m25, Tstatprohibit_m30, Tstatprohibit_m35, Tstatprohibit_m40, Tstatprohibit_m45, Tstatprohibit_m50, Tstatprohibit_m55, Tstatprohibit_m60, Tstatprohibit_m65, Tstatprohibit_m70, Tstatprohibit_m75, Tstatprohibit_m80, Tstatprohibit_m40(4 None Tstatprohibit_m85, 0ms) Tstatprohibit_m90, Tstatprohibit_m95, Tstatprohibit_m100, Tstatprohibit_m105, Tstatprohibit_m110, Tstatprohibit_m115, Tstatprohibit_m120, Tstatprohibit_m125, Tstatprohibit_m130, Tstatprohibit_m135, Tstatprohibit_m140, Tstatprohibit_m145, Tstatprohibit_m150, Tstatprohibit_m155, Tstatprohibit_m160, Tstatprohibit_m165,

Default/Recommen RlcPdcpParaGroup ded Value

Treordering_m0, Treordering_m5, Treordering_m10, Treordering_m15, Treordering_m20, Treordering_m25, Treordering_m30, Treordering_m35, Treordering_m40, Treordering_m45, Treordering_m50, Treordering_m55, Treordering_m60, Treordering_m65, Treordering_m70, Treordering_m50(5 Treordering_m75, None 0ms) Treordering_m80, Treordering_m85, Treordering_m90, Treordering_m95, Treordering_m100, Treordering_m110, Treordering_m120, Treordering_m130, Treordering_m140, Treordering_m150, Treordering_m160, Treordering_m170, Treordering_m180, Treordering_m190, Treordering_m200

Default/Recommen RlcPdcpParaGroup ded Value

Treordering_m0, Treordering_m5, Treordering_m10, Treordering_m15, Treordering_m20, Treordering_m25, Treordering_m30, Treordering_m35, Treordering_m40, Treordering_m45, Treordering_m50, Treordering_m55, Treordering_m60, Treordering_m65, Treordering_m70, Treordering_m40(4 Treordering_m75, None 0ms) Treordering_m80, Treordering_m85, Treordering_m90, Treordering_m95, Treordering_m100, Treordering_m110, Treordering_m120, Treordering_m130, Treordering_m140, Treordering_m150, Treordering_m160, Treordering_m170, Treordering_m180, Treordering_m190, Treordering_m200

Default/Recommen RlcPdcpParaGroup ded Value

PdcpSnsize_7bits, PdcpSnsize_12bits( None PdcpSnsize_12bits 12 bits)

Default/Recommen RlcPdcpParaGroup ded Value

RlcSnSize_size5, RlcSnSize_size10

RlcSnSize_size10(1 None 0bits)

Default/Recommen RlcPdcpParaGroup ded Value

RlcSnSize_size5, RlcSnSize_size10

RlcSnSize_size10(1 None 0bits)

Default/Recommen RlcPdcpParaGroup ded Value

Treordering_m0, Treordering_m5, Treordering_m10, Treordering_m15, Treordering_m20, Treordering_m25, Treordering_m30, Treordering_m35, Treordering_m40, Treordering_m45, Treordering_m50, Treordering_m55, Treordering_m60, Treordering_m65, Treordering_m70, Treordering_m50(5 Treordering_m75, None 0ms) Treordering_m80, Treordering_m85, Treordering_m90, Treordering_m95, Treordering_m100, Treordering_m110, Treordering_m120, Treordering_m130, Treordering_m140, Treordering_m150, Treordering_m160, Treordering_m170, Treordering_m180, Treordering_m190, Treordering_m200

Default/Recommen RlcPdcpParaGroup ded Value

Treordering_m0, Treordering_m5, Treordering_m10, Treordering_m15, Treordering_m20, Treordering_m25, Treordering_m30, Treordering_m35, Treordering_m40, Treordering_m45, Treordering_m50, Treordering_m55, Treordering_m60, Treordering_m65, Treordering_m70, Treordering_m50(5 Treordering_m75, None 0ms) Treordering_m80, Treordering_m85, Treordering_m90, Treordering_m95, Treordering_m100, Treordering_m110, Treordering_m120, Treordering_m130, Treordering_m140, Treordering_m150, Treordering_m160, Treordering_m170, Treordering_m180, Treordering_m190, Treordering_m200

Default/Recommen RlcPdcpParaGroup ded Value

FALSE, TRUE

TRUE(TRUE)

TRUE(TRUE)

Default/Recommen RlcPdcpParaGroup ded Value

QCI1, QCI2, QCI3, QCI4, QCI5, QCI6, None QCI7, QCI8, QCI9

None

Engineering Design StandardQci

0.001~1, step:0.001 700

QCI6: 1000 QCI7: 900 QCI8: 800 QCI9: 700

Engineering Design StandardQci

0.001~1, step:0.001 700

QCI6: 1000 QCI7: 900 QCI8: 800 QCI9: 700

Engineering Design StandardQci

MinGbrRate_0_KB, MinGbrRate_1_KB, MinGbrRate_2_KB, MinGbrRate_4KB, MinGbrRate_8_KB, MinGbrRate_16_KB , MinGbrRate_32_KB MinGbrRate_1_KB( MinGbrRate_1_KB( , Engineering Design StandardQci 1KB/s) 1KB/s) MinGbrRate_64_KB , MinGbrRate_128_K B, MinGbrRate_256_K B, MinGbrRate_512_K B

MinGbrRate_0_KB, MinGbrRate_1_KB, MinGbrRate_2_KB, MinGbrRate_4KB, MinGbrRate_8_KB, MinGbrRate_16_KB , MinGbrRate_32_KB MinGbrRate_1_KB( MinGbrRate_1_KB( , Engineering Design StandardQci 1KB/s) 1KB/s) MinGbrRate_64_KB , MinGbrRate_128_K B, MinGbrRate_256_K B, MinGbrRate_512_K B

0~1, step:0.1

10

10

Engineering Design StandardQci

0~39

None

Engineering Design StandardQci

0~39

None

Engineering Design StandardQci

PBR_0_KBps, PBR_8_KBps, PBR_16_KBps, PBR_32_KBps, PBR_64_KBps, PBR_128_KBps, PBR_256_KBps, PBR_INFINITY

PBR_8_KBps(8KB/ PBR_8_KBps(8KB/ Engineering Design StandardQci s) s)

9~16

11

QCI 6: 9 QCI 7: 10 QCI 8: 11 QCI 9: 12

Engineering Design StandardQci

FLOW_CTRL, FLOW_CTRL(Flow None NON_FLOW_CTRL Control)

Engineering Design StandardQci

CLASS_0, CLASS_1, CLASS_2

CLASS_1(CLASS_ CLASS_1(CLASS_ Default/Recommen AlgoDefaultPara 1) 1) ded Value

NO_ADAPTIVE, TxD_BF_ADAPTIV MIMO_BF_ADAPTI MIMO_BF_ADAPTI BfMimoAdaptivePar E, VE(MIMO_BF_ADA VE(MIMO_BF_ADA Engineering Design aCfg MIMO_BF_ADAPTI PTIVE) PTIVE) VE

TM2, TM3, TM7, TM8, TM4

TM3(TM3)

TM3(TM3)

Engineering Design

BfMimoAdaptivePar aCfg

OFF, ON

ON(On)

ON(On)

Engineering Design CqiAdaptiveCfg

ms2, ms5, ms10, ms20, ms32, ms40, ms40(40ms) ms64, ms80, ms128, ms160

ms40(40ms)

Engineering Design CqiAdaptiveCfg

NO_ADAPTIVE, OL_ADAPTIVE, CL_ADAPTIVE, OC_ADAPTIVE

OL_ADAPTIVE(OL OL_ADAPTIVE(OL MimoAdaptivePara Engineering Design _ADAPTIVE) _ADAPTIVE) Cfg

TM2, TM3, TM4, TM6

TM3(TM3)

TM3(TM3)

Engineering Design

MimoAdaptivePara Cfg

OFF, ON

ON(On)

ON(On)

Engineering Design SrsAdaptiveCfg

ms5, ms10, ms20, ms40

ms40(40ms)

ms40(40ms)

Engineering Design SrsAdaptiveCfg

QCI1, QCI2, QCI3, QCI4, QCI5, QCI6, None QCI7, QCI8, QCI9

None

Engineering Design TypDrbBsr

TPeriodBSRTimer_ sf5, TPeriodBSRTimer_ sf10, TPeriodBSRTimer_ sf16, TPeriodBSRTimer_ sf20, TPeriodBSRTimer_ sf32, TPeriodBSRTimer_ sf40, TPeriodBSRTimer_ sf64, TPeriodBSRTimer_ TPeriodBSRTimer_ None sf80, sf10(10 subframes) TPeriodBSRTimer_ sf128, TPeriodBSRTimer_ sf160, TPeriodBSRTimer_ sf320, TPeriodBSRTimer_ sf640, TPeriodBSRTimer_ sf1280, TPeriodBSRTimer_ sf2560, TPeriodBSRTimer_i nfinity

Default/Recommen TypDrbBsr ded Value

sf320, sf640, sf1280, sf2560, sf5120, sf10240

sf320(sf320)

None

Default/Recommen TypDrbBsr ded Value

GAP_PATTERN_T YPE_1, GAP_PATTERN_T GAP_PATTERN_T Default/Recommen HoMeasComm GAP_PATTERN_T YPE_1 YPE_1 ded Value YPE_2

FC0, FC1, FC2, FC3, FC4, FC5, FC6, FC7, FC8, FC6 FC9, FC11, FC13, FC15, FC17, FC19

FC6

Default/Recommen HoMeasComm ded Value

FC0, FC1, FC2, FC3, FC4, FC5, FC6, FC7, FC8, FC6 FC9, FC11, FC13, FC15, FC17, FC19

FC6

Default/Recommen HoMeasComm ded Value

FC0, FC1, FC2, FC3, FC4, FC5, FC6, FC7, FC8, FC6 FC9, FC11, FC13, FC15, FC17, FC19

FC6

Default/Recommen HoMeasComm ded Value

NOT_CFG, CFG

NOT_CFG

NOT_CFG

Default/Recommen HoMeasComm ded Value

-141~-43

-44

-44

Default/Recommen HoMeasComm ded Value

NOT_CFG, CFG

NOT_CFG

NOT_CFG

Default/Recommen HoMeasComm ded Value

T_CRMAX_30S, T_CRMAX_60S, T_CRMAX_120S, T_CRMAX_180S, T_CRMAX_240S

T_CRMAX_60S(60 T_CRMAX_60S(60 Default/Recommen HoMeasComm s) s) ded Value

T_CRMAXHYST_3 0S, T_CRMAXHYST_6 0S, T_CRMAXHYST_1 T_CRMAXHYST_6 T_CRMAXHYST_6 Default/Recommen HoMeasComm 20S, 0S(60s) 0S(60s) ded Value T_CRMAXHYST_1 80S, T_CRMAXHYST_2 40S

1~16

Default/Recommen HoMeasComm ded Value

1~16

Default/Recommen HoMeasComm ded Value

TTT_SF_MEDIUM_ 0DOT25, TTT_SF_MEDIUM_ 0DOT50, TTT_SF_MEDIUM_ TTT_SF_MEDIUM_ Default/Recommen HoMeasComm TTT_SF_MEDIUM_ LDOT0(1) LDOT0(1) ded Value 0DOT75, TTT_SF_MEDIUM_ LDOT0

TTT_SF_HIGH_0D OT25, TTT_SF_HIGH_0D OT50, TTT_SF_HIGH_0D TTT_SF_HIGH_0D Default/Recommen HoMeasComm TTT_SF_HIGH_0D OT75(0.75) OT75(0.75) ded Value OT75, TTT_SF_HIGH_LD OT0

FC0, FC1, FC2, FC3, FC4, FC5, FC6, FC7, FC8, FC6 FC9, FC11, FC13, FC15, FC17, FC19

FC6

Default/Recommen HoMeasComm ded Value

FC0, FC1, FC2, FC3, FC4, FC5, FC6, FC7, FC8, FC6 FC9, FC11, FC13, FC15, FC17, FC19

FC6

Default/Recommen HoMeasComm ded Value

1~8

Default/Recommen InterRatHoComm ded Value

r1, r2, r4, r8, r16, r32, r64, Infinity

Infinity(Infinity)

infinity(Infinity)

Default/Recommen InterRatHoComm ded Value

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 480ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

480ms

Default/Recommen InterRatHoComm ded Value

UTRAN_RSCP, UTRAN_ECN0, UTRAN_BOTH

UTRAN_RSCP

UTRAN_RSCP

Default/Recommen InterRatHoComm ded Value

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 480ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

480ms

Default/Recommen InterRatHoComm ded Value

PILOT_STRENGTH , Default/Recommen PILOT_STRENGTH PILOT_STRENGTH InterRatHoComm PILOT_PN_PHASE ded Value _AND_STRENGTH

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 480ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

480ms

Default/Recommen InterRatHoComm ded Value

PILOT_STRENGTH PILOT_STRENGTH PILOT_STRENGTH

Default/Recommen InterRatHoComm ded Value

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 480ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

480ms

Engineering Design InterRatHoComm

RSRP, RSRQ, BOTH

RSRP

RSRP

Default/Recommen InterRatHoComm ded Value

EventB1, EventB2

EventB1(EventB1)

EventB1(EventB1)

Default/Recommen InterRatHoComm ded Value

1~8

Default/Recommen IntraRatHoComm ded Value

r1, r2, r4, r8, r16, r32, r64, Infinity

Infinity(Infinity)

infinity(Infinity)

Default/Recommen IntraRatHoComm ded Value

RSRP, RSRQ

RSRP

RSRP

Default/Recommen IntraRatHoComm ded Value

SAME_AS_TRIG_ QUAN, BOTH

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

Default/Recommen IntraRatHoComm ded Value

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 240ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

240ms

Default/Recommen IntraRatHoComm ded Value

SAME_AS_TRIG_ QUAN, BOTH

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

Default/Recommen IntraRatHoComm ded Value

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 240ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

240ms

Default/Recommen IntraRatHoComm ded Value

RSRP, RSRQ, BOTH

RSRP

RSRP

Default/Recommen IntraRatHoComm ded Value

RSRP, RSRQ, BOTH

RSRP

RSRP

Default/Recommen IntraRatHoComm ded Value

RSRP, RSRQ, BOTH

RSRP

RSRP

Default/Recommen IntraRatHoComm ded Value

0~17

None

None

Radio Planning (Internal planning)

CSFallBackHo

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

40ms

40ms

Radio Planning (Internal planning)

CSFallBackHo

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

40ms

40ms

Radio Planning (Internal planning)

CSFallBackHo

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

40ms

40ms

Radio Planning (Internal planning)

CSFallBackHo

-120~-25

-106

-106

Radio Planning (Internal planning)

CSFallBackHo

-24~0, step:0.5

-13

-13

Radio Planning (Internal planning)

CSFallBackHo

-110~-48

-103

-103

Radio Planning (Internal planning)

CSFallBackHo

-31.5~0, step:0.5

-34

-34

Default/Recommen CSFallBackHo ded Value

0~17

None

None

Radio Planning (Internal planning)

CellAcBar

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellAcBar

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Engineering Design CellAcBar BOOLEAN_TRUE False) False)

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellAcBar

P00, P05, P10, P15, P20, P25, P30, P40, P50, P95(95%) P60, P70, P75, P80, P85, P90, P95

P95(95%)

Default/Recommen CellAcBar ded Value

ACCESS_BARRIN G_TIME_S4, ACCESS_BARRIN G_TIME_S8, ACCESS_BARRIN G_TIME_S16, ACCESS_BARRIN G_TIME_S32, ACCESS_BARRIN ACCESS_BARRIN Default/Recommen CellAcBar ACCESS_BARRIN G_TIME_S4(4s) G_TIME_S4(4s) ded Value G_TIME_S64, ACCESS_BARRIN G_TIME_S128, ACCESS_BARRIN G_TIME_S256, ACCESS_BARRIN G_TIME_S512

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellAcBar

P00, P05, P10, P15, P20, P25, P30, P40, P50, P95(95%) P60, P70, P75, P80, P85, P90, P95

P95(95%)

Default/Recommen CellAcBar ded Value

ACCESS_BARRIN G_TIME_S4, ACCESS_BARRIN G_TIME_S8, ACCESS_BARRIN G_TIME_S16, ACCESS_BARRIN G_TIME_S32, ACCESS_BARRIN ACCESS_BARRIN Default/Recommen CellAcBar ACCESS_BARRIN G_TIME_S4(4s) G_TIME_S4(4s) ded Value G_TIME_S64, ACCESS_BARRIN G_TIME_S128, ACCESS_BARRIN G_TIME_S256, ACCESS_BARRIN G_TIME_S512

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen CellAcBar BOOLEAN_TRUE False) False) ded Value

0~17

None

None

Radio Planning (Internal planning)

CellAccess

CELL_BARRED, CELL_NOT_BARR CELL_NOT_BARR Default/Recommen CELL_NOT_BARR CellAccess ED(Not Barred) ED(Not Barred) ded Value ED

CELL_RESERVED, CELL_NOT_RESE CELL_NOT_RESE Default/Recommen CELL_NOT_RESE RVED(Not RVED(Not CellAccess ded Value RVED Reserved) Reserved)

ALLOWED, NOT_ALLOWED

ALLOWED

ALLOWED

Default/Recommen CellAccess ded Value

NORMAL_MODE, RR_MODE

NORMAL_MODE(N NORMAL_MODE(N Default/Recommen CellAccess ormal mode) ormal mode) ded Value

1~720

Default/Recommen CellAccess ded Value

0~17

None

None

Radio Planning (Internal planning)

CellOp

0~65535

None

None

Radio Planning (Internal planning)

CellOp

CELL_RESERVED CELL_NOT_RESE CELL_NOT_RESE _FOR_OP, Default/Recommen RVED_FOR_OP(N RVED_FOR_OP(N CellOp CELL_NOT_RESE ded Value ot Reserved) ot Reserved) RVED_FOR_OP

1~100

25

25

Default/Recommen CellOp ded Value

1~100

25

25

Default/Recommen CellOp ded Value

0~3

None

None

N/A

CellOp

0~17

None

None

Radio Planning (Internal planning)

CellResel

DB0_Q_HYST, DB1_Q_HYST, DB2_Q_HYST, DB3_Q_HYST, DB4_Q_HYST, DB5_Q_HYST, DB6_Q_HYST, DB8_Q_HYST, DB10_Q_HYST, DB12_Q_HYST, DB14_Q_HYST, DB16_Q_HYST, DB18_Q_HYST, DB20_Q_HYST, DB22_Q_HYST, DB24_Q_HYST

DB4_Q_HYST(4dB) DB4_Q_HYST(4dB)

Default/Recommen CellResel ded Value

NOT_CFG, CFG

CFG(Configure)

CFG(Configure)

Engineering Design CellResel

S30_T_EVALULATI ON, S60_T_EVALULATI ON, S120_T_EVALULA S60_T_EVALULATI S60_T_EVALULATI Default/Recommen CellResel TION, ON(60s) ON(60s) ded Value S180_T_EVALULA TION, S240_T_EVALULA TION

S30_T_HYST_NOR MAL, S60_T_HYST_NOR MAL, S120_T_HYST_NO S30_T_HYST_NOR S30_T_HYST_NOR Default/Recommen CellResel RMAL, MAL(30s) MAL(30s) ded Value S180_T_HYST_NO RMAL, S240_T_HYST_NO RMAL

1~16

Default/Recommen CellResel ded Value

1~16

Default/Recommen CellResel ded Value

DB_6_Q_HYST_SF _MEDIUM, DB_4_Q_HYST_SF _MEDIUM, DB0_Q_HYST_SF_ DB0_Q_HYST_SF_ Default/Recommen CellResel DB_2_Q_HYST_SF MEDIUM(0dB) MEDIUM(0dB) ded Value _MEDIUM, DB0_Q_HYST_SF_ MEDIUM

DB_6_Q_HYST_SF _HIGH, DB_4_Q_HYST_SF _HIGH, DB0_Q_HYST_SF_ DB0_Q_HYST_SF_ Default/Recommen CellResel DB_2_Q_HYST_SF HIGH(0dB) HIGH(0dB) ded Value _HIGH, DB0_Q_HYST_SF_ HIGH

NOT_CFG, CFG

CFG(Configure)

CFG(Configure)

Engineering Design CellResel

0~62, step:2

10

10

Default/Recommen CellResel ded Value

0~62, step:2

10

10

Default/Recommen CellResel ded Value

0~7

Default/Recommen CellResel ded Value

-140~-44, step:2

-64

-64

Default/Recommen CellResel ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellResel

-30~33

23

23

Default/Recommen CellResel ded Value

NOT_CFG, CFG

CFG(Configure)

CFG(Configure)

Engineering Design CellResel

0~62, step:2

29

29

Default/Recommen CellResel ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellResel

MBW6, MBW15, MBW25, MBW50, MBW75, MBW100

MBW6(1.4M)

DL bandwidth of the Radio Planning serving cell (Internal planning)

CellResel

0~7

Default/Recommen CellResel ded Value

NOT_CFG, CFG

CFG(Configure)

CFG(Configure)

Engineering Design CellResel

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_1DO T_RESEL_SF_1DO Default/Recommen CellResel T_RESEL_SF_0DO T0(1.0) T0(1.0) ded Value T75, T_RESEL_SF_1DO T0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_0DO T_RESEL_SF_0DO Default/Recommen CellResel T_RESEL_SF_0DO T75(0.75) T75(0.75) ded Value T75, T_RESEL_SF_1DO T0

BitString00, BitString01, BitString10, BitString11

BitString01(01)

BitString01(01)

Default/Recommen CellResel ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Engineering Design CellResel BOOLEAN_TRUE False) False)

0~31

Default/Recommen CellResel ded Value

0~31

Default/Recommen CellResel ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellResel

0~31

Default/Recommen CellResel ded Value

NOT_CFG, CFG

CFG(Configure)

CFG(Configure)

Engineering Design CellResel

-34~-3

-18

-18

Default/Recommen CellResel ded Value

0~17

None

None

Radio Planning (Internal planning)

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

BOOLEAN_FALSE, BOOLEAN_TRUE( BOOLEAN_TRUE( CellReselCdma200 Engineering Design BOOLEAN_TRUE True) True) 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~15

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

0~255

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~255

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~255

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_0DO T_RESEL_SF_0DO Default/Recommen CellReselCdma200 T_RESEL_SF_0DO T75(0.75) T75(0.75) ded Value 0 T75, T_RESEL_SF_1DO T0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_1DO T_RESEL_SF_1DO Default/Recommen CellReselCdma200 T_RESEL_SF_0DO T0(1.0) T0(1.0) ded Value 0 T75, T_RESEL_SF_1DO T0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~32767

Engineering Design

CellReselCdma200 0

0~65535

Engineering Design

CellReselCdma200 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Engineering Design BOOLEAN_TRUE False) False) 0

0~127

Engineering Design

CellReselCdma200 0

0~4095

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~6 characters

NULL

None

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_1DO T_RESEL_SF_1DO Default/Recommen CellReselCdma200 T_RESEL_SF_0DO T0(1.0) T0(1.0) ded Value 0 T75, T_RESEL_SF_1DO T0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_0DO T_RESEL_SF_0DO Default/Recommen CellReselCdma200 T_RESEL_SF_0DO T75(0.75) T75(0.75) ded Value 0 T75, T_RESEL_SF_1DO T0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design

CellReselCdma200 0

0~63

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~7

Engineering Design

CellReselCdma200 0

0~17

None

None

Radio Planning (Internal planning)

CellReselGeran

0~7

Default/Recommen CellReselGeran ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellReselGeran

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_1DO T_RESEL_SF_1DO Default/Recommen CellReselGeran T_RESEL_SF_0DO T0(1.0) T0(1.0) ded Value T75, T_RESEL_SF_1DO T0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_0DO T_RESEL_SF_0DO Default/Recommen CellReselGeran T_RESEL_SF_0DO T75(0.75) T75(0.75) ded Value T75, T_RESEL_SF_1DO T0

0~17

None

None

Radio Planning (Internal planning)

CellReselUtran

0~7

Default/Recommen CellReselUtran ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design CellReselUtran

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_1DO T_RESEL_SF_1DO Default/Recommen CellReselUtran T_RESEL_SF_0DO T0(1.0) T0(1.0) ded Value T75, T_RESEL_SF_1DO T0

T_RESEL_SF_0DO T25, T_RESEL_SF_0DO T5, T_RESEL_SF_0DO T_RESEL_SF_0DO Default/Recommen CellReselUtran T_RESEL_SF_0DO T75(0.75) T75(0.75) ded Value T75, T_RESEL_SF_1DO T0

0~17

None

None

Radio Planning (Internal planning)

CellSel

-140~-44, step:2

-64

-64

Default/Recommen CellSel ded Value

0~16, step:2

Default/Recommen CellSel ded Value

-34~-3

-18

-18

Default/Recommen CellSel ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen CellSel ded Value

1~8

None

Engineering Design CellSel

0~17

None

None

Radio Planning (Internal planning)

CellSiMap

BOOLEAN_FALSE, BOOLEAN_TRUE( BOOLEAN_TRUE( Engineering Design CellSiMap BOOLEAN_TRUE True) True)

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF16(16 radio frames)

RF16(16 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF16(16 radio frames)

RF16(16 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF32(32 radio frames)

RF32(32 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF32(32 radio frames)

RF32(32 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF64(64 radio frames)

RF64(64 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF64(64 radio frames)

RF64(64 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF64(64 radio frames)

RF64(64 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF16(16 radio frames)

RF16(16 radio frames)

Default/Recommen CellSiMap ded Value

RF8, RF16, RF32, RF64, RF128, RF256, RF512

RF32(32 radio frames)

RF32(32 radio frames)

Default/Recommen CellSiMap ded Value

1~300

Default/Recommen CellSiMap ded Value

MERGE, DISCARD DISCARD

DISCARD

Default/Recommen CellSiMap ded Value

MERGE, DISCARD DISCARD

DISCARD

Default/Recommen CellSiMap ded Value

0~17

None

None

Radio Planning (Internal planning)

CellUlpcComm

AL0, AL04, AL05, AL06, AL07, AL08, AL07(0.7) AL09, AL1

AL07(0.7)

Default/Recommen CellUlpcComm ded Value

-127~-96

-105

-105

Default/Recommen CellUlpcComm ded Value

-126~24

-67

-67

Default/Recommen CellUlpcComm ded Value

DELTAF_2, DELTAF0, DELTAF2

DELTAF0(0dB)

DELTAF0(0dB)

Default/Recommen CellUlpcComm ded Value

DELTAF1, DELTAF3, DELTAF5

DELTAF3(3dB)

DELTAF3(3dB)

Default/Recommen CellUlpcComm ded Value

DELTAF_2, DELTAF0, DELTAF1, DELTAF2

DELTAF1(1dB)

DELTAF1(1dB)

Default/Recommen CellUlpcComm ded Value

DELTAF_2, DELTAF0, DELTAF2

DELTAF2(2dB)

DELTAF2(2dB)

Default/Recommen CellUlpcComm ded Value

DELTAF_2, DELTAF0, DELTAF2

DELTAF2(2dB)

DELTAF2(2dB)

Default/Recommen CellUlpcComm ded Value

-2~12, step:2

Default/Recommen CellUlpcComm ded Value

0~17

None

None

N/A

TimeAlignmentTime r

SF500, SF750, SF1280, SF1920, SF1920 SF2560, SF5120, SF10240, INFINITY

If the long DRX cycle length is required to be greater than or N/A equal to 80 ms, it is recommended that this parameter be set to SF2560.

TimeAlignmentTime r

0~17

None

None

Radio Planning (Internal planning)

UeTimerConst

MS100_T300, MS200_T300, MS300_T300, MS400_T300, MS600_T300, MS1000_T300, MS1500_T300, MS2000_T300

MS200_T300(200m MS200_T300(200m Default/Recommen UeTimerConst s) s) ded Value

MS100_T301, MS200_T301, MS300_T301, MS400_T301, MS600_T301, MS1000_T301, MS1500_T301, MS2000_T301

MS200_T301(200m MS200_T301(200m Default/Recommen UeTimerConst s) s) ded Value

MS0_T310, MS50_T310, MS100_T310, MS200_T310, MS500_T310, MS1000_T310, MS2000_T310

MS1000_T310(100 MS1000_T310(100 Default/Recommen UeTimerConst 0ms) 0ms) ded Value

MS1000_T311, MS3000_T311, MS5000_T311, MS10000_T311, MS15000_T311, MS20000_T311, MS30000_T311

MS10000_T311(10 MS10000_T311(10 Default/Recommen UeTimerConst 000ms) 000ms) ded Value

n1, n2, n3, n4, n5, n6, n8, n10

n1(1)

n1(1)

Default/Recommen UeTimerConst ded Value

n1, n2, n3, n4, n6, n8, n10, n20

n10(10)

n10(10)

Default/Recommen UeTimerConst ded Value

0~17

None

None

Radio Planning (Internal planning)

Cell

1~99 characters

None

None

Radio Planning (Internal planning)

Cell

0~17

None

None

Radio Planning (Internal planning)

Cell

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Engineering Design Cell BOOLEAN_TRUE False) False)

NORMAL_CP, EXTENDED_CP

NORMAL_CP(Norm NORMAL_CP(Norm Radio Planning al) al) (Internal planning)

Cell

NORMAL_CP, EXTENDED_CP

NORMAL_CP(Norm NORMAL_CP(Norm Radio Planning al) al) (Internal planning)

Cell

1~43,61~64

None

None

Radio Planning (Internal planning)

Cell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen Cell ded Value

18000~45589,6443 18000 6~65535

None

Radio Planning (Internal planning)

Cell

0~45589,64436~65 None 535

None

Radio Planning (Internal planning)

Cell

CELL_BW_N6, CELL_BW_N15, CELL_BW_N25, CELL_BW_N50, CELL_BW_N75, CELL_BW_N100

None

None

Radio Planning (Internal planning)

Cell

CELL_BW_N6, CELL_BW_N15, CELL_BW_N25, CELL_BW_N50, CELL_BW_N75, CELL_BW_N100

None

None

Radio Planning (Internal planning)

Cell

0~255

None

None

Radio Planning (Internal planning)

Cell

0~503

None

None

Radio Planning (Internal planning)

Cell

1~32

Default/Recommen Cell ded Value

CELL_DEACTIVE, CELL_ACTIVE

CELL_DEACTIVE( CELL_DEACTIVE( Default/Recommen Cell Deactivated) Deactivated) ded Value

CELL_UNBLOCK, CELL_HIGH_BLOC K, CELL_UNBLOCK(U CELL_UNBLOCK(U CELL_MIDDLE_BL Engineering Design Cell nblock) nblock) OCK, CELL_LOW_BLOC K

1~1440

60

60

Default/Recommen Cell ded Value

CELL_FDD, CELL_TDD

None

None

Radio Planning (Internal planning)

Cell

SA0, SA1, SA2, SA3, SA4, SA5, SA6

SA0(SA0)

None

Radio Planning (Internal planning)

Cell

SSP0, SSP1, SSP2, SSP3, SSP0(SSP0) SSP4, SSP5, SSP6, SSP7, SSP8

None

Radio Planning (Internal planning)

Cell

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB0(0dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB0(0dB)

Engineering Design Cell

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB0(0dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB0(0dB)

Engineering Design Cell

0~837

None

Logical root sequences for each cell must be configured based on the network plan. The tool for configuring ZadoffChu (ZC) root sequences is recommended. During manual configuration, the following rules apply: 1. If two neighboring cells use the same or overlapping time- Radio Planning frequency (Internal planning) resources for the physical random access channel (PRACH), they must have different values of this parameter. 2. If a cell uses a preamble format less than 4 and provides coverage for a highway or an ultra-high-speed railway, this parameter must be set by referring to

Cell

LOW_SPEED, HIGH_SPEED, ULTRA_HIGH_SPE LOW_SPEED(Low LOW_SPEED(Low Engineering Design Cell ED, speed cell flag) speed cell flag) EXTRA_HIGH_SPE ED

0~4

Cell radius <= 1400 m:Preamble formats 0 to 3 are applicable to an FDD cell, preamble formats 0 to 4 are applicable to a TDD cell; 1400 m < Cell radius <= 14,500 m:Preamble formats 0 to 3 are applicable; 14,500 m < Cell Default/Recommen Cell radius <= 29,500 ded Value m:Preamble formats 1 to 3 are applicable; 29,500 m < Cell radius <= 77,300 m:Preamble formats 1 and 3 are applicable; 77,300 m < Cell radius <= 100,000 m:Preamble format 3 is applicable.

1~100000

10000

10000

Radio Planning (Internal planning)

Cell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Radio Planning (Internal planning)

Cell

4.8~5.0,9.6~10.0,14 .6~15.0,18.3~20.0, 98 step:0.1

98

Radio Planning (Internal planning)

Cell

4.8~5.0,9.6~10.0,14 .6~15.0,18.3~20.0, 98 step:0.1

98

Radio Planning (Internal planning)

Cell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen Cell ded Value

0~16777215

None

Radio Planning (Internal planning)

Cell

NOT_CFG, CFG

NOT_CFG(Not configure)

None

N/A

Cell

-30~36

23

23

N/A

Cell

BOOLEAN_FALSE, BOOLEAN_FALSE( None BOOLEAN_TRUE False)

Radio Planning (Internal planning)

Cell

SFN, CELL_COMBINATI ON, TWO_RRU_COMBI SFN(SFN) NATION, DIGITAL_COMBIN ATION

None

Radio Planning (Internal planning)

Cell

NO_COMPRESSIO N, NO_COMPRESSIO None NORMAL_COMPR N(No Compression) ESSION

Radio Planning (Internal planning)

Cell

CELL_INST_UNIN STALL, CELL_INST_UEM_ CFGING, CELL_INST_RRU_ CFGING, CELL_INST_BBI_C FGING, CELL_INST_RECF GING, None CELL_INST_DELE TING, CELL_INST_NORM AL, CELL_INST_BARR ED, CELL_INST_ALLO CATING_RES, CELL_INST_CRM_ CFGING

None

N/A

Cell

NO_INFORMATIO N, CCEM_FAILURE, CCEM_CELLALG_ ERR_CODE_NON_ BF_VERSION_CEL LACT_FAILED, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_BF_SW_ ON, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_MUBF_S W, CCEM_CELLALG_ ERR_CODE_NO_S None UPPORT_VMIMO_ SW, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_INTRA_S UB_FRAM, CCEM_CELLALG_ ERR_CODE_NO_S UPPORT_EXTERN D_CP, CCEM_CH_PUSC H_HOPING_OFFS ET_INVALID_CFG, CCEM_CH_PUCC H_PRACH_INTER SECTION_ERROR, CCEM_CH_PUCC 0~32 characters None

None

N/A

Cell

None

N/A

Cell

CELL_NO_OP, CELL_SETUP_ACT , CELL_SETUP_UBL , CELL_SETUP_HE ALCHK, CELL_SETUP_141, CELL_SETUP_UL WIDESCAN, CELL_DEL_BLK_L OW, CELL_DEL_BLK_M ID, CELL_DEL_BLK_H IGH, None CELL_DEL_NOUS ER, CELL_DEL_DEA, CELL_DEL_RMV, CELl_DEL_HEALC HK, CELL_DEL_UNHE AL, CELL_DEL_SETUP _FAIL, CELL_DEL_141_D EL, CELL_DEL_ULWID ESCAN, CELL_DEL_CELLN OACCESSALM

None

N/A

Cell

0~32 characters

None

None

N/A

Cell

CELL_NO_OP, CELL_SETUP_ACT , CELL_SETUP_UBL , CELL_SETUP_HE ALCHK, CELL_SETUP_141, CELL_SETUP_UL WIDESCAN, CELL_DEL_BLK_L OW, CELL_DEL_BLK_M ID, CELL_DEL_BLK_H IGH, None CELL_DEL_NOUS ER, CELL_DEL_DEA, CELL_DEL_RMV, CELl_DEL_HEALC HK, CELL_DEL_UNHE AL, CELL_DEL_SETUP _FAIL, CELL_DEL_141_D EL, CELL_DEL_ULWID ESCAN, CELL_DEL_CELLN OACCESSALM

None

N/A

Cell

CELL_PWRSAVE_ UNINSTALL, CELL_PWRSAVE_ RFSHD, CELL_PWRSAVE_ CELLSHD, CELL_PWRSAVE_ LOWPWR_CELLU SEDPWRRDU, CELL_PWRSAVE_ LOWPWR_RSPW None RRDU, CELL_PWRSAVE_ LOWPWR_RFSHD, CELL_PWRSAVE_ LOWPWR_CELLS HD, AUTO_PWROFF_ ONTIME, CELL_PWRSAVE_I NTERRAT_CELLS HD

None

N/A

Cell

BBI_SLOT_0, BBI_SLOT_1, BBI_SLOT_2, BBI_SLOT_3, None BBI_SLOT_4, BBI_SLOT_5, BBI_SLOT_INVALI D

None

N/A

Cell

BASIC_TYPE, TWO_RRU_COMBI NATION_TYPE, SFN_TYPE, BF_TYPE, MIMO_HELP_TYP None E, CELL_COMBINATI ON_TYPE, DIGITAL_COMBIN ATION_TYPE, INVALID_TYPE

None

N/A

Cell

0~62

None

None

N/A

Cell

4~254

None

None

N/A

Cell

0~8

None

None

N/A

Cell

UNINSTALL, SYMBOL_SHUTDO None WN

None

N/A

Cell

0~65535

None

None

N/A

Cell

0~17

None

None

Radio Planning (Internal planning)

CellBf

SINGLE_LAYER_B SINGLE_LAYER_B F, None F DUAL_LAYER_BF

Engineering Design CellBf

0~17

None

None

Radio Planning (Internal planning)

CellDLIcicMcPara

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 5120ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

5120ms

Default/Recommen CellDLIcicMcPara ded Value

1~8

Default/Recommen CellDLIcicMcPara ded Value

r1, r2, r4, r8, r16, r32, r64, Infinity

Infinity(Infinity)

Infinity(Infinity)

Default/Recommen CellDLIcicMcPara ded Value

SAME_AS_TRIG_ QUAN, BOTH

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

Default/Recommen CellDLIcicMcPara ded Value

RSRP, RSRQ

RSRP

RSRP

Default/Recommen CellDLIcicMcPara ded Value

0~15, step:0.5

Default/Recommen CellDLIcicMcPara ded Value

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

640ms

Default/Recommen CellDLIcicMcPara ded Value

-15~15, step:0.5

-13

-13

Default/Recommen CellDLIcicMcPara ded Value

0~17

None

None

Radio Planning (Internal planning)

CellLowPower

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design CellLowPower

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CellLowPower ded Value

00:00:00~23:59:59

00:00:00

00:00:00

Default/Recommen CellLowPower ded Value

00:00:00~23:59:59

06:00:00

06:00:00

Default/Recommen CellLowPower ded Value

0~1440

120

120

Default/Recommen CellLowPower ded Value

0~1440

120

120

Default/Recommen CellLowPower ded Value

0~1440

120

120

Default/Recommen CellLowPower ded Value

10~100

50

50

Default/Recommen CellLowPower ded Value

-10~0

-1

-1

Default/Recommen CellLowPower ded Value

1~1440

Default/Recommen CellLowPower ded Value

0~17

None

None

Radio Planning (Internal planning)

CellMro

NOT_CFG, CFG

NOT_CFG(Not configure)

None

Engineering Design CellMro

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB24(24dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

None

Engineering Design CellMro

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB-24(-24dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

None

Engineering Design CellMro

0~17

None

None

Radio Planning (Internal planning)

CellRacThd

1~15

Engineering Design CellRacThd

1~15

10

10

Engineering Design CellRacThd

10~99

90

90

Engineering Design CellRacThd

10~99

90

90

Engineering Design CellRacThd

10~99

90

90

Engineering Design CellRacThd

10~99

90

90

Engineering Design CellRacThd

0~90

Engineering Design CellRacThd

0~90

Engineering Design CellRacThd

0~90

Engineering Design CellRacThd

0~99

65

65

Engineering Design CellRacThd

0~99

65

65

Engineering Design CellRacThd

0~99

65

65

Engineering Design CellRacThd

0~99

65

65

Engineering Design CellRacThd

1~100

90

90

Engineering Design CellRacThd

1~100

90

90

Engineering Design CellRacThd

1~100

90

90

Engineering Design CellRacThd

0~100

95

95

Engineering Design CellRacThd

0~100

90

90

Engineering Design CellRacThd

1~15

10

10

Engineering Design CellRacThd

0~50

20

20

Engineering Design CellRacThd

1~15

Engineering Design CellRacThd

10~100

95

95

Engineering Design CellRacThd

10~100

95

95

Engineering Design CellRacThd

10~100

90

90

Engineering Design CellRacThd

10~100

90

90

Engineering Design CellRacThd

0~9000

3000

Set the parameter based on actual service requirements. The recommended values are described as follows: FDD: For a cell with a 1.4 MHz bandwidth, a value in the range of 0 to 560 is recommended; For a cell with a 3 MHz bandwidth, a value in the range Engineering Design CellRacThd of 0 to 1800 is recommended; For a cell with a 5 MHz bandwidth, a value in the range of 0 to 3000 is recommended; For a cell with a 10 MHz bandwidth, a value in the range of 0 to 3000 is recommended; For a cell with a 15 MHz bandwidth, a value in the range of 0 to 6000 is recommended;

0~17

None

None

Radio Planning (Internal planning)

CellRfShutdown

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design CellRfShutdown

00:00:00~23:59:59

00:00:00

00:00:00

Default/Recommen CellRfShutdown ded Value

00:00:00~23:59:59

06:00:00

06:00:00

Default/Recommen CellRfShutdown ded Value

0~7

Engineering Design CellRfShutdown

0~17

None

None

Radio Planning (Internal planning)

CellRicAlgo

OFF, ON

OFF(Off)

The value OFF is recommended if there is no remote interference to the cell. The value ON is recommended if there is remote interference to the cell.

Engineering Design CellRicAlgo

0~2

The value 0 is recommended if there is no remote interference to the cell. The value 1 is recommended if there is remote interference to the cell.

Engineering Design CellRicAlgo

OFF, ON

OFF(Off)

NOT_MUTE(NOT_ Radio Planning MUTE) (Internal planning)

CellRicAlgo

0~17

None

None

Radio Planning (Internal planning)

CellShutdown

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design CellShutdown

00:00:00~23:59:59

00:00:00

00:00:00

Default/Recommen CellShutdown ded Value

00:00:00~23:59:59

06:00:00

06:00:00

Default/Recommen CellShutdown ded Value

0~100

20

20

Default/Recommen CellShutdown ded Value

0~100

20

20

Default/Recommen CellShutdown ded Value

0~100

20

20

Default/Recommen CellShutdown ded Value

0~100

20

20

Default/Recommen CellShutdown ded Value

0~17

None

None

Radio Planning (Internal planning)

CellULIcicMcPara

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 5120ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

5120ms

Default/Recommen CellULIcicMcPara ded Value

1~8

Default/Recommen CellULIcicMcPara ded Value

r1, r2, r4, r8, r16, r32, r64, Infinity

Infinity(Infinity)

Infinity(Infinity)

Default/Recommen CellULIcicMcPara ded Value

SAME_AS_TRIG_ QUAN, BOTH

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

SAME_AS_TRIG_ QUAN(Same as Trig Quan)

Default/Recommen CellULIcicMcPara ded Value

RSRP, RSRQ

RSRP

RSRP

Default/Recommen CellULIcicMcPara ded Value

0~15, step:0.5

Default/Recommen CellULIcicMcPara ded Value

0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

640ms

640ms

Default/Recommen CellULIcicMcPara ded Value

-15~15, step:0.5

-10

-10

Default/Recommen CellULIcicMcPara ded Value

0~17

None

None

Radio Planning (Internal planning)

CellUlschAlgo

Scenario A: The EPF policy is recommended on live networks. Scenario B: The MAX C/I policy is recommended when the operator or Huawei desires to verify the system performance in maximum capacities. ULSCH_STRATEG Scenario C: The PF Y_EPF, policy is ULSCH_STRATEG recommended when Y_MAX_CI, ULSCH_STRATEG Default/Recommen the operator or CellUlschAlgo ULSCH_STRATEG Y_EPF(EPF) ded Value Huawei desires to Y_PF, verify the system ULSCH_STRATEG performance in Y_RR scenarios where the capacity, coverage, and fairness reach a tradeoff. Scenario D: The RR policy is recommended when the operator or Huawei desires to verify that each UE has an equal opportunity to be scheduled.

ADAPTIVE_HARQ_ SW_ON, ADAPTIVE_HARQ_ ADAPTIVE_HARQ_ ADAPTIVE_HARQ_ SW_SEMI_ON(Se SW_SEMI_ON(Se Engineering Design CellUlschAlgo SW_OFF, miOn) miOn) ADAPTIVE_HARQ_ SW_SEMI_ON

0.01~0.99, step:0.01

10

10

Default/Recommen CellUlschAlgo ded Value

0~100

50

50

Default/Recommen CellUlschAlgo ded Value

1~40

Default/Recommen CellUlschAlgo ded Value

45~1500

80

80

Default/Recommen CellUlschAlgo ded Value

HOPPING_OFF, HOPPING_TYPE1, HOPPING_OFF(Ho HOPPING_OFF(Ho Default/Recommen HOPPING_TYPE2, CellUlschAlgo pping off) pping off) ded Value HOPPING_TYPE2_ RANDOM

0~100

Default/Recommen CellUlschAlgo ded Value

16~15000

600

600

Default/Recommen CellUlschAlgo ded Value

2~3

Scenario A: The recommended value is 3 if the cell serves a large number of cell center users Default/Recommen CellUlschAlgo (CCUs). ded Value Scenario B: The recommended value is 2 in commercial networks.

0~17

None

None

Radio Planning (Internal planning)

InterRatCellShutdo wn

OFF, ON

OFF(Off)

None

Engineering Design

InterRatCellShutdo wn

00:00:00~23:59:59

03:00:00

None

Default/Recommen InterRatCellShutdo ded Value wn

00:00:00~23:59:59

05:00:00

None

Default/Recommen InterRatCellShutdo ded Value wn

0~5000

20

None

Default/Recommen InterRatCellShutdo ded Value wn

0~100

10

None

Default/Recommen InterRatCellShutdo ded Value wn

0~100

10

None

Default/Recommen InterRatCellShutdo ded Value wn

0~17

None

None

Radio Planning (Internal planning)

CellAlgoSwitch

RachAdjSwitch, HoRaSwitch, UnsyncRaSwitch, MaksIdxSwitch, BackOffSwitch

RachAdjSwitch:Off, HoRaSwitch:On, UnsyncRaSwitch:O n, MaksIdxSwitch:Off, BackOffSwitch:Off

RachAdjSwitch:Off HoRaSwitch:On UnsyncRaSwitch:O Engineering Design CellAlgoSwitch n MaksIdxSwitch:Off BackOffSwitch:Off

SrsSubframeRecfS SrsSubframeRecfS SrsSubframeRecfS Engineering Design CellAlgoSwitch witch witch:On witch:On

PucchSwitch

PucchSwitch:On

In ultra-high-speed scenarios, the recommended value of PucchSwitch is Engineering Design CellAlgoSwitch OFF. In other scenarios, the recommended value of PucchSwitch is ON.

AqmAlgoSwitch

AqmAlgoSwitch:Off AqmAlgoSwitch:Off Engineering Design CellAlgoSwitch

CqiAdjAlgoSwitch, StepVarySwitch

CqiAdjAlgoSwitch:O CqiAdjAlgoSwitch:O n, n Engineering Design CellAlgoSwitch StepVarySwitch:Off StepVarySwitch:Off

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design CellAlgoSwitch

DynAdjVoltSwitch

Dynamic Adjust Voltage Switch:Off

Dynamic Adjust Voltage Switch:Off

Engineering Design CellAlgoSwitch

dlCacSwitch:Off, ulCacSwitch:Off, dlCacPredictSwitch: DlSwitch, UlSwitch, Off, DlPredictSwitch, ulCacPredictSwitch: UlPredictSwitch, Off, GbrUsageSwitch, GbrUsedPRbCheck DlLdcSwitch, Switch:Off, UlLdcSwitch, dlLdcSwitch:Off, RelDrbSwitch, ulLdcSwitch:Off, PreemptionSwitch LdcDrbRelSwitch:Of f, PreemptionSwitch: Off

DlSwitch:Off UlSwitch:Off DlPredictSwitch:Off UlPredictSwitch:Off GbrUsageSwitch:Of f Engineering Design CellAlgoSwitch DlLdcSwitch:Off UlLdcSwitch:Off RelDrbSwitch:Off PreemptionSwitch: Off

IntraFreqMlbSwitch: Off, IntraFreqMlbSwitch, InterFreqMlbSwitch: InterFreqMlbSwitch, Off, UtranMlbSwitch, UtranMlbSwitch:Off, GeranMlbSwitch, GeranMlbSwitch:Off CdmaMlbSwitch, , IntraFreqIdleMlbSwi CdmaMlbSwitch:Off tch , IntraFreqIdleMlbSwi tch:Off

It is recommended that IntraFreqMlbSwitch and IntraFreqIdleMlbSwi tch be set to OFF, when the cell load is light in an early stage of network deployment (that is, the average cell load is lower than 50%) and there is no obvious imbalance in the cell loads (that is, the load difference Engineering Design CellAlgoSwitch between cells is lower than the related threshold). It is recommended that IntraFreqMlbSwitch and IntraFreqIdleMlbSwi tch be set to ON when the cell load is heavy (that is, the average load in the cell exceeds IntraFreqMlbThd) and there is an imbalance in the cell loads (that is,

PdschSpsPcSwitch: PdschSpsPcSwitch, Off, PhichInnerLoopPcS PhichInnerLoopPcS witch, witch:Off, PdcchPcSwitch PdcchPcSwitch:On

PdschSpsPcSwitch: Off PhichInnerLoopPcS Engineering Design CellAlgoSwitch witch:Off PdcchPcSwitch:On

CloseLoopSpsSwitc h, InnerLoopPuschSwi tch, PhSinrTarUpdateS witch, InnerLoopPucchSwi tch, OiSinrTarUpdateSw itch, PowerSavingSwitch

CloseLoopSpsSwitc h:Off, InnerLoopPuschSwi tch:On, PhSinrTarUpdateS witch:Off, InnerLoopPucchSwi tch:On, OiSinrTarUpdateSw itch:Off, PowerSavingSwitch :Off

CloseLoopSpsSwitc h:Off InnerLoopPuschSwi tch:On PhSinrTarUpdateS witch:Off Engineering Design CellAlgoSwitch InnerLoopPucchSwi tch:On OiSinrTarUpdateSw itch:Off PowerSavingSwitch :Off

BfSwitch

BfSwitch:Off

BfSwitch:Off

Engineering Design CellAlgoSwitch

FreqSelSwitch, ServiceDiffSwitch, SpsSchSwitch, MBSFNShutDownS witch

FreqSelSwitch:Off, ServiceDiffSwitch:O ff, SpsSchSwitch:Off, MBSFNShutDownS witch:Off

FreqSelSwitch:Off ServiceDiffSwitch:O ff Engineering Design CellAlgoSwitch SpsSchSwitch:Off MBSFNShutDownS witch:Off

SpsSchSwitch:Off, SpsSchSwitch, SinrAdjustSwitch:O SinrAdjustSwitch, n, PreAllocationSwitch PreAllocationSwitch , UlVmimoSwitch, :On, TtiBundlingSwitch, UlVmimoSwitch:Off, ImIcSwitch TtiBundlingSwitch:O ff, ImIcSwitch:Off

SpsSchSwitch:Off SinrAdjustSwitch:O n PreAllocationSwitch :On Engineering Design CellAlgoSwitch UlVmimoSwitch:Off TtiBundlingSwitch:O ff ImIcSwitch:Off

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CellAlgoSwitch ded Value

FreqPriorIFHOSwitc h, FreqPriorIFBlindHO Switch

FreqPriorIFHOSwitc h:Off, FreqPriorIFBlindHO Switch:On

FreqPriorIFHOSwitc h:Off Default/Recommen CellAlgoSwitch FreqPriorIFBlindHO ded Value Switch:On

MuBfSwitch

MuBfSwitch:Off

MuBfSwitch:Off

Default/Recommen CellAlgoSwitch ded Value

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen CellAlgoSwitch ded Value

ACBAR_SWITCH_ DYNAMIC, ACBAR_SWITCH_ ACBAR_SWITCH_ ACBAR_SWITCH_ STATIC(static STATIC(static Engineering Design CellAlgoSwitch STATIC, configuration) configuration) ACBAR_SWITCH_ DISABLE

DISABLE, ENABLE DISABLE(Disable)

None

Engineering Design CellAlgoSwitch

DISABLE, ENABLE ENABLE(Enable)

None

Engineering Design CellAlgoSwitch

0~17

None

None

Radio Planning (Internal planning)

CellDlIcic

MODE1, MODE2, MODE3, INVALID

If this parameter is not set to INVALID(Invalid DL band division scheme), it is recommended that this parameter be set to a different value from those of neighboring cells. If INVALID(Invalid DL it is impossible for band division neighboring cells to Engineering Design CellDlIcic scheme) use mutually different band modes, it is recommended that this parameter be set to the same value as that of a neighboring cell that has the weakest interference with the current cell. Radio Planning (Internal planning)

0~17

None

None

CellDlpcPdcch

-15~15, step:0.1

-30

-30

Default/Recommen CellDlpcPdcch ded Value

0~17

None

None

Radio Planning (Internal planning)

CellDlpcPdsch

PA_NEG6, PA_NEG4DOT77, PA_NEG3, PA_NEG6(-6dB) PA_NEG1DOT77, PA_0, PA_1, PA_2, PA_3

PA_NEG6(-6dB)

Default/Recommen CellDlpcPdsch ded Value

PA_NEG6, PA_NEG4DOT77, PA_NEG3, PA_NEG1DOT77(- PA_NEG1DOT77(- Default/Recommen CellDlpcPdsch PA_NEG1DOT77, 1.77dB) 1.77dB) ded Value PA_0, PA_1, PA_2, PA_3

0~17

None

None

Radio Planning (Internal planning)

CellDlpcPhich

-15~15, step:0.1

Default/Recommen CellDlpcPhich ded Value

0~17

None

None

Radio Planning (Internal planning)

CellDlschAlgo

DLSCH_PRI_TYPE _EPF, DLSCH_PRI_TYPE _PF, DLSCH_PRI_TYPE DLSCH_PRI_TYPE Engineering Design CellDlschAlgo DLSCH_PRI_TYPE _EPF(EPF) _EPF(EPF) _MAX_CI, DLSCH_PRI_TYPE _RR

0~100

Engineering Design CellDlschAlgo

0~1, step:0.01

Engineering Design CellDlschAlgo

0~1, step:0.01

10

10

Engineering Design CellDlschAlgo

SW_MAX_SM_RA NK_1, SW_MAX_SM_RA NK_2, SW_MAX_SM_RA NK_4

SW_MAX_SM_RA NK_2

None

Engineering Design CellDlschAlgo

0~17

None

None

Radio Planning (Internal planning)

CellMLB

1~100

60

60

Engineering Design CellMLB

1~100

60

60

Engineering Design CellMLB

1~100

75

75

Engineering Design CellMLB

LOAD_EXCHANGE _PERIOD_1S, LOAD_EXCHANGE _PERIOD_2S, LOAD_EXCHANGE LOAD_EXCHANGE Default/Recommen CellMLB LOAD_EXCHANGE _PERIOD_5S(5s) _PERIOD_5S(5s) ded Value _PERIOD_5S, LOAD_EXCHANGE _PERIOD_10S

0~50

Default/Recommen CellMLB ded Value

1~50

15

15

Default/Recommen CellMLB ded Value

0~17

None

None

Radio Planning (Internal planning)

CellPdcchAlgo

CONGREG_LV4, CONGREG_LV8

CONGREG_LV4

CONGREG_LV4

Engineering Design CellPdcchAlgo

OFF, ON

ON(On)

ON(On)

Engineering Design CellPdcchAlgo

1~4

If the switch for dynamic adjustment to the number of OFDM symbols occupied by the PDCCH is turned on, set this parameter to 1. If the switch for dynamic adjustment to the number of OFDM symbols occupied by the PDCCH is turned off, set this parameter to 4 for the bandwidth of 1.4 Engineering Design CellPdcchAlgo MHz and to 3 for other bandwidths. In addition, if this switch is turned off for a smallbandwidth cell, PDCCH resources may be insufficient due to the smaller number of occupied OFDM symbols, and accordingly UEs cannot access the cell. In this scenario, set this parameter to 3 for the bandwidth of 1.4

0~100

Engineering Design CellPdcchAlgo

OFF, ON

ON(On)

In non-ultra-highspeed scenarios where the eNodeB operates in FDD mode, the Engineering Design CellPdcchAlgo recommended value is ON. In other scenarios, the recommended value is OFF.

1~100

100

There is also a lower limit for the CCE usage within each TTI. If the value of this parameter is relatively small, the PDCCH has insufficient CCE resources, which will affect the access success rate of cell edge UEs (CEUs), handover success rate, CCE assignment success rate for DL Engineering Design CellPdcchAlgo scheduling, and especially that for UL scheduling. Therefore, at least 24 available CCEs are required within each TTI. The lower limits for the CCE usage within each TTI are described as follows for cells with different configurations: (1) If the cell bandwidth and the number of PDCCH symbols are 10

OFF, ON

ON(On)

ON(On)

Engineering Design CellPdcchAlgo

0~17

None

None

Radio Planning (Internal planning)

CellPucchAlgo

0~50

10

In FDD mode, the recommended value is 0 for bandwidths of 1.4 MHz and 3 MHz, 10 for bandwidths of 5 MHz and 10 MHz, and 20 for bandwidths of 15 MHz and 20 MHz. In TDD mode with the SubframeAssignme nt parameter set to SA0 or SA1, the recommended value is 0 for Default/Recommen CellPucchAlgo bandwidths of 1.4 ded Value MHz and 3 MHz, and 5 for bandwidths of 5 MHz, 10 MHz, 15 MHz, and 20 MHz. In TDD mode with the SubframeAssignme nt parameter set to SA2 or SA5, the recommended value is 0 for all bandwidths. If a competition test on the access delay or handover delay is

0~17

None

None

Radio Planning (Internal planning)

CellNoAccessAlmP ara

00:00:00~23:59:59

00:00:00

00:00:00

Default/Recommen CellNoAccessAlmP ded Value ara

00:00:00~23:59:59

00:00:00

00:00:00

Default/Recommen CellNoAccessAlmP ded Value ara

0~72

Default/Recommen CellNoAccessAlmP ded Value ara

0~17

None

None

Radio Planning (Internal planning)

CellUlIcic

MODE1, MODE2, MODE3, INVALID

If this parameter is not set to INVALID(Invalid UL band division scheme), it is recommended that this parameter be set to a different value from those of neighboring cells. If INVALID(Invalid UL it is impossible for band division neighboring cells to Engineering Design CellUlIcic scheme) use mutually different band modes, it is recommended that this parameter be set to the same value as that of a neighboring cell that has the weakest interference with the current cell.

0~17

None

None

Radio Planning (Internal planning)

CellSimuLoad

0~9

Default/Recommen CellSimuLoad ded Value

TM1, TM2, TM7, TM8

TM2(TM2)

TM2(TM2)

Default/Recommen CellSimuLoad ded Value

0~100

None

None

N/A

CellSimuLoad

0~100

None

None

N/A

CellSimuLoad

0~100, step:0.01

None

None

N/A

CellSimuLoad

0~100, step:0.01

None

None

N/A

CellSimuLoad

0~1200

None

None

N/A

CellSimuLoad

0~1200

None

None

N/A

CellSimuLoad

0~17

None

None

Radio Planning (Internal planning)

BcchCfg

MOD_PERIOD_CO EFF_N2, MOD_PERIOD_CO EFF_N4, MOD_PERIOD_CO MOD_PERIOD_CO Default/Recommen BcchCfg MOD_PERIOD_CO EFF_N2(2) EFF_N4(4) ded Value EFF_N8, MOD_PERIOD_CO EFF_N16

0~17

None

None

Radio Planning (Internal planning)

CellChPwrCfg

-15.875~15.875, step:0.005

-600

The recommended value is 0 for TDD cells with bandwidths of 10 Default/Recommen MHz, 15 MHz, and CellChPwrCfg ded Value 20 MHz, and -600 for TDD cells with other bandwidths and all FDD cells.

-15.875~15.875, step:0.005

-600

-600 in normal scenarios and peak rate tests, or 0 in Default/Recommen CellChPwrCfg the tests on the ded Value maximum cell radius.

-15.875~15.875, step:0.005

Default/Recommen CellChPwrCfg ded Value

-15.875~15.875, step:0.005

-600

-600 in normal scenarios and peak rate tests, or 0 in Default/Recommen CellChPwrCfg the tests on the ded Value maximum cell radius.

-15.875~15.875, step:0.005

Default/Recommen CellChPwrCfg ded Value

-15.875~15.875, step:0.005

Default/Recommen CellChPwrCfg ded Value

-15.875~15.875, step:0.005

Default/Recommen CellChPwrCfg ded Value

0~17

None

None

Radio Planning (Internal planning)

PDSCHCfg

-60~50, step:0.1

182

None

Default/Recommen PDSCHCfg ded Value

0~3

Single-antenna: 0; double-antenna: 1

Default/Recommen PDSCHCfg ded Value

0~17

None

None

Radio Planning (Internal planning)

RACHCfg

DB0_PWR_RAMPI NG_STEP, DB2_PWR_RAMPI NG_STEP, DB2_PWR_RAMPI DB2_PWR_RAMPI Default/Recommen RACHCfg DB4_PWR_RAMPI NG_STEP(2dB) NG_STEP(2dB) ded Value NG_STEP, DB6_PWR_RAMPI NG_STEP

DBM_120, DBM_118, DBM_116, DBM_114, DBM_112, DBM_110, DBM_108, DBM_104(DBM_106, 104dBm) DBM_104, DBM_102, DBM_100, DBM_98, DBM_96, DBM_94, DBM_92, DBM_90

DBM_104(104dBm)

Default/Recommen RACHCfg ded Value

B56_MSG_SIZE_G ROUPA, B144_MSG_SIZE_ GROUPA, B56_MSG_SIZE_G B56_MSG_SIZE_G Default/Recommen RACHCfg B208_MSG_SIZE_ ROUPA(56bits) ROUPA(56bits) ded Value GROUPA, B256_MSG_SIZE_ GROUPA

0~94

None

Engineering Design RACHCfg

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen RACHCfg ded Value

0~63

For FDD cells established on an LBBPd: If preamble format 0 is used, this parameter can be set to 15 or a value in the range of 0 to 8. If preamble format 1 is used, this parameter can be set to 31 or a value in the range of 16 to 24. If preamble format 2 is used, this Engineering Design RACHCfg parameter can be set to 47 or a value in the range of 32 to 37. If preamble format 3 is used, this parameter can be set to 63 or a value in the range of 48 to 53. For FDD cells established on an LBBPc: If a cell is configured with the speed flag of LOW_SPEED, None Radio Planning (Internal planning) SRSCfg

0~17

None

SC0, SC1, SC2, SC3, SC4, SC5, SC6, SC7, SC8, SC3(3) SC9, SC10, SC11, SC12, SC13, SC14

The value SC3(3) is recommended for FDD cells. Engineering Design SRSCfg The value SC0(0) is recommended for TDD cells.

BOOLEAN_FALSE, BOOLEAN_TRUE( BOOLEAN_TRUE( Default/Recommen SRSCfg BOOLEAN_TRUE True) True) ded Value

It is recommended that this parameter be set to BOOLEAN_TRUE( True) if any of the following conditions is met: (1) The MimoAdaptiveSwitc BOOLEAN_FALSE, BOOLEAN_TRUE( h parameter is set Default/Recommen SRSCfg BOOLEAN_TRUE True) to OC_ADAPTIVE; ded Value (2) UlVmimoSwitch under the UlSchSwitch parameter is turned on; (3) The WM parameter in the BBP MO is set to TDD_ENHANCE.

ACCESS_FIRST, ACCESS_FIRST(A ACCESS_FIRST(A EXPERIENCE_FIR Engineering Design SRSCfg ccess First) ccess First) ST

BW0, BW1, BW2, BW3, BW4, BW5, BW6, BW7

None

None

N/A

SRSCfg

0~17

None

None

Radio Planning (Internal planning)

PHICHCfg

NORMAL, EXTENDED

NORMAL

NORMAL

Default/Recommen PHICHCfg ded Value

ONE_SIXTH, HALF, ONE, TWO

ONE

ONE

Default/Recommen PHICHCfg ded Value

0~17

None

None

Radio Planning (Internal planning)

PCCHCfg

rf32, rf64, rf128, rf256

rf128(128 radio frames)

rf128(128 radio frames)

Default/Recommen PCCHCfg ded Value

FOURT, TWOT, ONET, HALFT, QUARTERT, ONE_EIGHTT, ONET ONE_SIXTEENTHT , ONE_THIRTY_SEC ONDT

ONET

Default/Recommen PCCHCfg ded Value

0~17

None

None

Radio Planning (Internal planning)

PUSCHCfg

1~4

If UlHoppingType and HoppingMode are set to HOPPING_TYPE2 and INTER_SUB_FRA ME, respectively, the recommended value of this parameter is 4. If UlHoppingType and HoppingMode are set to HOPPING_TYPE2 and INTRA_AND_INTE R_SUB_FRAME, Default/Recommen PUSCHCfg respectively, the ded Value recommended value of this parameter is 1. If UlHoppingType and HoppingMode are set to HOPPING_TYPE2_ RANDOM and INTER_SUB_FRA ME, respectively, the recommended value of this parameter is 4. If UlHoppingType and HoppingMode are set to INTER_SUB_FRA ME(Inter) Default/Recommen PUSCHCfg ded Value

INTER_SUB_FRA ME, INTER_SUB_FRA INTRA_AND_INTE ME(Inter) R_SUB_FRAME

0~98

22

In FDD cells with the normal CP length, if DeltaShift is set to DS1_DELTA_SHIF T, the recommended values of this parameter are 2, 4, 7, 10, 11, and 11, corresponding to cell bandwidths in ascending order; if DeltaShift is set to DS2_DELTA_SHIF T, the recommended Default/Recommen PUSCHCfg values of this ded Value parameter are 2, 4, 8, 12, 13, and 14, corresponding to cell bandwidths in ascending order; if DeltaShift is set to DS3_DELTA_SHIF T, the recommended values of this parameter are 2, 6, 9, 16, 17, and 19, corresponding to cell bandwidths in ascending order. In FDD cells with

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Engineering Design PUSCHCfg BOOLEAN_TRUE False) False)

0~29

Engineering Design PUSCHCfg

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Engineering Design PUSCHCfg BOOLEAN_TRUE False) False)

0~7

Default/Recommen PUSCHCfg ded Value

No recommended value. The value BOOLEAN_FALSE, BOOLEAN_TRUE( should be set based Engineering Design PUSCHCfg BOOLEAN_TRUE True) on the 64QAM capability of the UE. 0~17 None None Radio Planning (Internal planning) PUCCHCfg

Set this parameter to DS2_DELTA_SHIF T for a cell configured with the LBBPc and the normal cyclic prefix (CP). Set this parameter to DS3_DELTA_SHIF T for a cell DS1_DELTA_SHIF configured with the T, LBBPc and the DS2_DELTA_SHIF DS1_DELTA_SHIF Default/Recommen extended CP. PUCCHCfg T, T(ds1) ded Value Set this parameter DS3_DELTA_SHIF to T DS1_DELTA_SHIF T for a cell configured with the LBBPd and the normal CP. Set this parameter to DS3_DELTA_SHIF T for a cell configured with the LBBPd and the extended CP.

0~100

Engineering Design PUCCHCfg

0~20

Engineering Design PUCCHCfg

6~32 characters

None

None

Radio Planning (Internal planning)

Cdma2000External CellPlmn

000~999

None

None

Radio Planning (Internal planning)

Cdma2000External CellPlmn

00~99,000~999

None

None

Radio Planning (Internal planning)

Cdma2000External CellPlmn

0~17

None

None

Radio Planning (Internal planning)

Cdma2000HrpdNce ll

6~32 characters

None

None

Radio Planning (Internal planning)

Cdma2000HrpdNce ll

PERMIT_HO_ENU M, PERMIT_HO_ENU PERMIT_HO_ENU Radio Planning FORBID_HO_ENU M(Permit Ho) M(Permit Ho) (Internal planning) M

Cdma2000HrpdNce ll

PERMIT_RMV_EN PERMIT_RMV_EN PERMIT_RMV_EN UM, Radio Planning UM(Permit ANR UM(Permit ANR FORBID_RMV_EN (Internal planning) Remove) Remove) UM

Cdma2000HrpdNce ll

0~32

Engineering Design

Cdma2000HrpdNce ll

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Cdma2000HrpdNce Engineering Design BOOLEAN_TRUE False) False) ll

0~99 characters

NULL

None

Engineering Design

Cdma2000HrpdNce ll

0~99 characters

NULL

None

Engineering Design

Cdma2000HrpdNce ll

0~17

None

None

Radio Planning (Internal planning)

Cdma2000Nfreq

bc0, bc1, bc2, bc3, bc4, bc5, bc6, bc7, bc8, bc9, bc10, None bc11, bc12, bc13, bc14, bc15, bc16, bc17

None

Radio Planning (Internal planning)

Cdma2000Nfreq

0~2047

None

None

Radio Planning (Internal planning)

Cdma2000Nfreq

-15~15

Engineering Design Cdma2000Nfreq

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design Cdma2000Nfreq

0~15

None

Engineering Design Cdma2000Nfreq

000~999

None

None

Radio Planning (Internal planning)

EutranExternalCellP lmn

00~99,000~999

None

None

Radio Planning (Internal planning)

EutranExternalCellP lmn

0~1048575

None

None

Radio Planning (Internal planning)

EutranExternalCellP lmn

0~255

None

None

Radio Planning (Internal planning)

EutranExternalCellP lmn

000~999

None

None

Radio Planning (Internal planning)

EutranExternalCellP lmn

00~99,000~999

None

None

Radio Planning (Internal planning)

EutranExternalCellP lmn

0~65535

None

None

Radio Planning (Internal planning)

GeranExternalCellP lmn

1~65533,65535

None

None

Radio Planning (Internal planning)

GeranExternalCellP lmn

000~999

None

None

Radio Planning (Internal planning)

GeranExternalCellP lmn

00~99,000~999

None

None

Radio Planning (Internal planning)

GeranExternalCellP lmn

000~999

None

None

Radio Planning (Internal planning)

GeranExternalCellP lmn

00~99,000~999

None

None

Radio Planning (Internal planning)

GeranExternalCellP lmn

0~268435455

None

None

Radio Planning (Internal planning)

UtranExternalCellPl mn

000~999

None

None

Radio Planning (Internal planning)

UtranExternalCellPl mn

00~99,000~999

None

None

Radio Planning (Internal planning)

UtranExternalCellPl mn

000~999

None

None

Radio Planning (Internal planning)

UtranExternalCellPl mn

00~99,000~999

None

None

Radio Planning (Internal planning)

UtranExternalCellPl mn

6~32 characters

None

None

Radio Planning (Internal planning)

Cdma2000External Cell

bc0, bc1, bc2, bc3, bc4, bc5, bc6, bc7, bc8, bc9, bc10, None bc11, bc12, bc13, bc14, bc15, bc16, bc17

None

Radio Planning (Internal planning)

Cdma2000External Cell

0~2047

None

None

Radio Planning (Internal planning)

Cdma2000External Cell

0~511

None

None

Radio Planning (Internal planning)

Cdma2000External Cell

CDMA2000_HRPD, CDMA2000_HRPD( CDMA2000_HRPD( Radio Planning CDMA2000_1XRTT CDMA2000_HRPD) CDMA2000_HRPD) (Internal planning)

Cdma2000External Cell

000~999

None

None

Radio Planning (Internal planning)

Cdma2000External Cell

00~99,000~999

None

None

Radio Planning (Internal planning)

Cdma2000External Cell

0~99 characters

NULL

None

Engineering Design

Cdma2000External Cell

0~17

None

None

Radio Planning (Internal planning)

Cdma20001XRTTN cell

6~32 characters

None

None

Radio Planning (Internal planning)

Cdma20001XRTTN cell

PERMIT_HO_ENU M, PERMIT_HO_ENU PERMIT_HO_ENU Radio Planning FORBID_HO_ENU M(Permit Ho) M(Permit Ho) (Internal planning) M

Cdma20001XRTTN cell

PERMIT_RMV_EN PERMIT_RMV_EN PERMIT_RMV_EN UM, Radio Planning UM(Permit ANR UM(Permit ANR FORBID_RMV_EN (Internal planning) Remove) Remove) UM

Cdma20001XRTTN cell

0~32

Engineering Design

Cdma20001XRTTN cell

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Cdma20001XRTTN Engineering Design BOOLEAN_TRUE False) False) cell

0~99 characters

NULL

None

Engineering Design

Cdma20001XRTTN cell

0~99 characters

NULL

None

Engineering Design

Cdma20001XRTTN cell

0~17

None

None

Radio Planning (Internal planning)

Cdma2000BandCla ss

bc0, bc1, bc2, bc3, bc4, bc5, bc6, bc7, bc8, bc9, bc10, None bc11, bc12, bc13, bc14, bc15, bc16, bc17

None

Radio Planning (Internal planning)

Cdma2000BandCla ss

0~7

Radio Planning (Internal planning)

Cdma2000BandCla ss

0~63

22

22

Radio Planning (Internal planning)

Cdma2000BandCla ss

0~63

22

22

Radio Planning (Internal planning)

Cdma2000BandCla ss

000~999

None

None

Radio Planning (Internal planning)

GeranExternalCell

00~99,000~999

None

None

Radio Planning (Internal planning)

GeranExternalCell

0~65535

None

None

Radio Planning (Internal planning)

GeranExternalCell

1~65533,65535

None

None

Radio Planning (Internal planning)

GeranExternalCell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen GeranExternalCell ded Value

0~255

None

Radio Planning (Internal planning)

GeranExternalCell

GSM_dcs1800, GSM_pcs1900

None

None

Radio Planning (Internal planning)

GeranExternalCell

0~1023

None

None

Radio Planning (Internal planning)

GeranExternalCell

0~7

None

None

Radio Planning (Internal planning)

GeranExternalCell

0~7

None

None

Radio Planning (Internal planning)

GeranExternalCell

DTM_AVAILABLE, DTM_NOT_AVAILA DTM_NOT_AVAILA Radio Planning DTM_NOT_AVAILA BLE BLE (Internal planning) BLE

GeranExternalCell

0~99 characters

NULL

None

Engineering Design GeranExternalCell

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Radio Planning BOOLEAN_TRUE False) False) (Internal planning)

GeranExternalCell

0~17

None

None

Radio Planning (Internal planning)

GeranNcell

000~999

None

None

Radio Planning (Internal planning)

GeranNcell

00~99,000~999

None

None

Radio Planning (Internal planning)

GeranNcell

1~65533,65535

None

None

Radio Planning (Internal planning)

GeranNcell

0~65535

None

None

Radio Planning (Internal planning)

GeranNcell

PERMIT_RMV_EN PERMIT_RMV_EN PERMIT_RMV_EN UM, UM(Permit ANR UM(Permit ANR Engineering Design GeranNcell FORBID_RMV_EN Remove) Remove) UM

PERMIT_HO_ENU M, PERMIT_HO_ENU PERMIT_HO_ENU Engineering Design GeranNcell FORBID_HO_ENU M(Permit Ho) M(Permit Ho) M

0~32

Engineering Design GeranNcell

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen GeranNcell BOOLEAN_TRUE False) False) ded Value

0~99 characters

NULL

None

Engineering Design GeranNcell

0~99 characters

NULL

None

Engineering Design GeranNcell

0~1048575

None

None

N/A

GeranNcell

0~32 characters

None

None

N/A

GeranNcell

0~32 characters

None

None

N/A

GeranNcell

0~17

None

None

Radio Planning (Internal planning)

GeranNfreqGroup

0~31

None

None

Radio Planning (Internal planning)

GeranNfreqGroup

GSM, GPRS, EDGE

None

None

Radio Planning (Internal planning)

GeranNfreqGroup

0~1023

None

None

Radio Planning (Internal planning)

GeranNfreqGroup

GSM_dcs1800, GSM_pcs1900

None

None

Radio Planning (Internal planning)

GeranNfreqGroup

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design GeranNfreqGroup

0~7

Engineering Design GeranNfreqGroup

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen GeranNfreqGroup ded Value

0~39

None

Engineering Design GeranNfreqGroup

-115~-25, step:2

Default/Recommen GeranNfreqGroup ded Value

0~62, step:2

Default/Recommen GeranNfreqGroup ded Value

0~62, step:2

Default/Recommen GeranNfreqGroup ded Value

-15~15

Default/Recommen GeranNfreqGroup ded Value

0~255

255

255

Default/Recommen GeranNfreqGroup ded Value

0~17

None

None

Radio Planning (Internal planning)

GeranNfreqGroupAr fcn

0~31

None

None

Radio Planning (Internal planning)

GeranNfreqGroupAr fcn

0~1023

None

None

Radio Planning (Internal planning)

GeranNfreqGroupAr fcn

0~17

None

None

Engineering Design IntraFreqBlkCell

0~503

None

None

Engineering Design IntraFreqBlkCell

0~99 characters

NULL

None

Engineering Design IntraFreqBlkCell

n1, n4, n8, n12, n16, n24, n32, n48, n64, n84, n96, n1(n1) n128, n168, n252, n504

None

Engineering Design IntraFreqBlkCell

0~17

None

None

Radio Planning (Internal planning)

EutranIntraFreqNCe ll

000~999

None

None

Radio Planning (Internal planning)

EutranIntraFreqNCe ll

00~99,000~999

None

None

Radio Planning (Internal planning)

EutranIntraFreqNCe ll

0~1048575

None

None

Radio Planning (Internal planning)

EutranIntraFreqNCe ll

0~255

None

None

Radio Planning (Internal planning)

EutranIntraFreqNCe ll

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB0(0dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB0(0dB)

Default/Recommen EutranIntraFreqNCe ded Value ll

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB0(0dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB0(0dB)

Default/Recommen EutranIntraFreqNCe ded Value ll

PERMIT_HO_ENU M, PERMIT_HO_ENU PERMIT_HO_ENU Radio Planning FORBID_HO_ENU M(Permit Ho) M(Permit Ho) (Internal planning) M

EutranIntraFreqNCe ll

PERMIT_RMV_EN PERMIT_RMV_EN PERMIT_RMV_EN UM, Radio Planning UM(Permit ANR UM(Permit ANR FORBID_RMV_EN (Internal planning) Remove) Remove) UM

EutranIntraFreqNCe ll

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen EutranIntraFreqNCe BOOLEAN_TRUE False) False) ded Value ll

0~99 characters

NULL

None

Engineering Design

EutranIntraFreqNCe ll

0~99 characters

NULL

None

Engineering Design

EutranIntraFreqNCe ll

0~17

None

None

Radio Planning (Internal planning)

EutranInterNFreq

0~45589,64436~65 None 535

None

Radio Planning (Internal planning)

EutranInterNFreq

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen EutranInterNFreq ded Value

18000~45589,6443 18000 6~65535

None

Radio Planning (Internal planning)

EutranInterNFreq

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen EutranInterNFreq ded Value

0~7

Radio Planning (Internal planning)

EutranInterNFreq

0~7

Default/Recommen EutranInterNFreq ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen EutranInterNFreq ded Value

0DOT25_ENUM, 0DOT5_ENUM, 0DOT75_ENUM, 1DOT0_ENUM

0DOT25_ENUM(0.2 None 5)

Engineering Design EutranInterNFreq

0DOT25_ENUM, 0DOT5_ENUM, 0DOT75_ENUM, 1DOT0_ENUM

0DOT25_ENUM(0.2 None 5)

Engineering Design EutranInterNFreq

MBW6, MBW15, MBW25, MBW50, MBW75, MBW100

None

None

Engineering Design EutranInterNFreq

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB1(1dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB1(1dB)

Default/Recommen EutranInterNFreq ded Value

0~62, step:2

11

11

Default/Recommen EutranInterNFreq ded Value

0~62, step:2

11

11

Default/Recommen EutranInterNFreq ded Value

-140~-44, step:2

-64

-64

Default/Recommen EutranInterNFreq ded Value

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen EutranInterNFreq ded Value

-30~33

23

23

Default/Recommen EutranInterNFreq ded Value

BitString00, BitString01, BitString10, BitString11

BitString01(01)

BitString01(01)

Default/Recommen EutranInterNFreq ded Value

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen EutranInterNFreq BOOLEAN_TRUE False) False) ded Value

EventA3, EventA4, EventA4(EventA4) EventA5

If the neighboring EUTRAN frequency and the serving frequency are in the same frequency band, the value EventA3 is recommended. Engineering Design EutranInterNFreq If the neighboring EUTRAN frequency and the serving frequency are in different frequency bands, the value EventA4 is recommended.

0~31

Radio Planning (Internal planning)

EutranInterNFreq

0~31

Radio Planning (Internal planning)

EutranInterNFreq

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Engineering Design EutranInterNFreq

-34~-3

-18

-18

Radio Planning (Internal planning)

EutranInterNFreq

0~17

None

None

Engineering Design InterFreqBlkCell

0~45589,64436~65 None 535

None

Engineering Design InterFreqBlkCell

0~503

None

None

Engineering Design InterFreqBlkCell

0~99 characters

NULL

None

Engineering Design InterFreqBlkCell

n1, n4, n8, n12, n16, n24, n32, n48, n64, n84, n96, n1(n1) n128, n168, n252, n504

None

Engineering Design InterFreqBlkCell

0~17

None

None

Radio Planning (Internal planning)

EutranInterFreqNCe ll

000~999

None

None

Radio Planning (Internal planning)

EutranInterFreqNCe ll

00~99,000~999

None

None

Radio Planning (Internal planning)

EutranInterFreqNCe ll

0~1048575

None

None

Radio Planning (Internal planning)

EutranInterFreqNCe ll

0~255

None

None

Radio Planning (Internal planning)

EutranInterFreqNCe ll

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB0(0dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB0(0dB)

Default/Recommen EutranInterFreqNCe ded Value ll

dB-24, dB-22, dB20, dB-18, dB-16, dB-14, dB-12, dB10, dB-8, dB-6, dB5, dB-4, dB-3, dB-2, dB-1, dB0, dB1, dB0(0dB) dB2, dB3, dB4, dB5, dB6, dB8, dB10, dB12, dB14, dB16, dB18, dB20, dB22, dB24

dB0(0dB)

Default/Recommen EutranInterFreqNCe ded Value ll

PERMIT_HO_ENU M, PERMIT_HO_ENU PERMIT_HO_ENU Radio Planning FORBID_HO_ENU M(Permit Ho) M(Permit Ho) (Internal planning) M

EutranInterFreqNCe ll

PERMIT_RMV_EN PERMIT_RMV_EN PERMIT_RMV_EN UM, Radio Planning UM(Permit ANR UM(Permit ANR FORBID_RMV_EN (Internal planning) Remove) Remove) UM

EutranInterFreqNCe ll

0~32

Radio Planning (Internal planning)

EutranInterFreqNCe ll

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen EutranInterFreqNCe BOOLEAN_TRUE False) False) ded Value ll

0~99 characters

NULL

None

Engineering Design

EutranInterFreqNCe ll

0~99 characters

NULL

None

Engineering Design

EutranInterFreqNCe ll

000~999

None

None

Radio Planning (Internal planning)

EutranExternalCell

00~99,000~999

None

None

Radio Planning (Internal planning)

EutranExternalCell

0~1048575

None

None

Radio Planning (Internal planning)

EutranExternalCell

0~255

None

None

Radio Planning (Internal planning)

EutranExternalCell

0~45589,64436~65 None 535

None

Radio Planning (Internal planning)

EutranExternalCell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen EutranExternalCell ded Value

18000~45589,6443 18000 6~65535

None

Radio Planning (Internal planning)

EutranExternalCell

0~503

None

None

Radio Planning (Internal planning)

EutranExternalCell

0~65535

None

None

Radio Planning (Internal planning)

EutranExternalCell

0~99 characters

NULL

None

Engineering Design EutranExternalCell

0~17

None

None

Radio Planning (Internal planning)

GeranRanShare

0~31

None

None

Radio Planning (Internal planning)

GeranRanShare

000~999

None

None

Radio Planning (Internal planning)

GeranRanShare

00~99,000~999

None

None

Radio Planning (Internal planning)

GeranRanShare

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Radio Planning (Internal planning)

GeranRanShare

0~7

Radio Planning (Internal planning)

GeranRanShare

0~17

None

None

Radio Planning (Internal planning)

UtranNCell

000~999

None

None

Radio Planning (Internal planning)

UtranNCell

00~99,000~999

None

None

Radio Planning (Internal planning)

UtranNCell

0~268435455

None

None

Radio Planning (Internal planning)

UtranNCell

PERMIT_HO_ENU M, PERMIT_HO_ENU PERMIT_HO_ENU Radio Planning FORBID_HO_ENU M(Permit Ho) M(Permit Ho) (Internal planning) M

UtranNCell

PERMIT_RMV_EN PERMIT_RMV_EN PERMIT_RMV_EN UM, Radio Planning UM(Permit ANR UM(Permit ANR FORBID_RMV_EN (Internal planning) Remove) Remove) UM

UtranNCell

0~32

Radio Planning (Internal planning)

UtranNCell

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen UtranNCell BOOLEAN_TRUE False) False) ded Value

0~99 characters

NULL

None

Engineering Design UtranNCell

0~99 characters

NULL

None

Engineering Design UtranNCell

0~1048575

None

None

N/A

UtranNCell

0~4095

None

None

N/A

UtranNCell

0~32 characters

None

None

N/A

UtranNCell

0~32 characters

None

None

N/A

UtranNCell

0~17

None

None

Radio Planning (Internal planning)

UtranRanShare

0~16383

None

None

Radio Planning (Internal planning)

UtranRanShare

000~999

None

None

Radio Planning (Internal planning)

UtranRanShare

00~99,000~999

None

None

Radio Planning (Internal planning)

UtranRanShare

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Radio Planning (Internal planning)

UtranRanShare

0~7

Radio Planning (Internal planning)

UtranRanShare

0~17

None

None

Radio Planning (Internal planning)

UtranNFreq

0~16383

None

None

Radio Planning (Internal planning)

UtranNFreq

R99, HSDPA, HSUPA, HSPA

HSUPA

HSUPA

Engineering Design UtranNFreq

UTRAN_FDD, UTRAN_TDD

UTRAN_FDD

UTRAN_FDD

Radio Planning (Internal planning)

UtranNFreq

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen UtranNFreq ded Value

0~16383

None

Radio Planning (Internal planning)

UtranNFreq

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen UtranNFreq ded Value

0~7

Radio Planning (Internal planning)

UtranNFreq

-50~33

33

33

Default/Recommen UtranNFreq ded Value

-15~15

Default/Recommen UtranNFreq ded Value

-24~0

-22

-22

Default/Recommen UtranNFreq ded Value

-119~-25, step:2

-58

-58

Default/Recommen UtranNFreq ded Value

0~62, step:2

Default/Recommen UtranNFreq ded Value

0~62, step:2

Default/Recommen UtranNFreq ded Value

0~31

Default/Recommen UtranNFreq ded Value

0~31

Default/Recommen UtranNFreq ded Value

LOW_PRIORITY, HIGH_PRIORITY

HIGH_PRIORITY(H HIGH_PRIORITY(H Engineering Design UtranNFreq igh Priority) igh Priority)

LOW_PRIORITY, HIGH_PRIORITY

HIGH_PRIORITY(H HIGH_PRIORITY(H Engineering Design UtranNFreq igh Priority) igh Priority)

000~999

None

None

Radio Planning (Internal planning)

UtranExternalCell

00~99,000~999

None

None

Radio Planning (Internal planning)

UtranExternalCell

0~268435455

None

None

Radio Planning (Internal planning)

UtranExternalCell

UTRAN_FDD, UTRAN_TDD

UTRAN_FDD

UTRAN_FDD

Engineering Design UtranExternalCell

0~16383

None

None

Radio Planning (Internal planning)

UtranExternalCell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen UtranExternalCell ded Value

0~16383

None

Radio Planning (Internal planning)

UtranExternalCell

0~4095

None

None

Radio Planning (Internal planning)

UtranExternalCell

NOT_CFG, CFG

NOT_CFG(Not configure)

NOT_CFG(Not configure)

Default/Recommen UtranExternalCell ded Value

0~255

None

Radio Planning (Internal planning)

UtranExternalCell

0~511

None

None

Radio Planning (Internal planning)

UtranExternalCell

1~65533,65535

None

None

Radio Planning (Internal planning)

UtranExternalCell

0~99 characters

NULL

None

Engineering Design UtranExternalCell

BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Default/Recommen UtranExternalCell BOOLEAN_TRUE False) False) ded Value

0~100

80

80

Engineering Design ANR

0~100

Engineering Design ANR

1~10000

200

200

Engineering Design ANR

1~10080

1440

1440

Engineering Design ANR

r1, r2, r4, r8, r16, r32, r64, Infinity

r64(64)

r64(64)

Engineering Design ANR

120ms, 240ms, 480ms, 640ms, 1024ms, 2048ms, 5120ms 5120ms, 10240ms, 1min, 6min, 12min, 30min, 60min

5120ms

Engineering Design ANR

1~10080

60

60

Engineering Design ANR

-130~-70

-102

-102

Engineering Design ANR

1~200

Engineering Design ANR

1~200

Engineering Design ANR

1~10000

20

20

Engineering Design ANR

1~10000

20

20

Engineering Design ANR

FREE, CONTROLLED

FREE(FREE)

FREE

Engineering Design ANR

1~50400

10080

10080

Engineering Design ANR

1~10000

200

200

Engineering Design ANR

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design ANR

00:00:00~23:59:59

14:00:00

14:00:00

Default/Recommen ANR ded Value

00:00:00~23:59:59

15:00:00

15:00:00

Default/Recommen ANR ded Value

-120~-25

-106

-106

Engineering Design ANR

-110~-48

-103

-103

Engineering Design ANR

-31.5~0, step:0.5

-30

-30

Engineering Design ANR

-31.5~0, step:0.5

-16

-16

Engineering Design ANR

BOOLEAN_FALSE, BOOLEAN_FALSE( None BOOLEAN_TRUE False)

Engineering Design CellIdPrdUpt

2000-0101T00:00:00.00000:00~2099-1231T23:59:59.00000:00

2000-0101T00:00:00.00000:00

None

Engineering Design CellIdPrdUpt

1~365

None

Engineering Design CellIdPrdUpt

IntraFreqCoverHoS witch, InterFreqCoverHoS witch, UtranCsfbSwitch, GeranCsfbSwitch, Cdma1xRttCsfbSwit ch, UtranServiceHoSwit ch, GeranServiceHoSwi tch, CdmaHrpdServiceH oSwitch, Cdma1xRttService HoSwitch, UlQualityInterRATH oSwitch, InterPlmnHoSwitch, UtranFlashCsfbSwit ch, GeranFlashCsfbSwi tch, ServiceBasedInterF reqHoSwitch, UlQualityInterFreqH oSwitch

IntraFreqCoverHoS witch:On, InterFreqCoverHoS witch:On, UtranCsfbSwitch:Of f, GeranCsfbSwitch:O ff, Cdma20001xRttCsf bSwitch:Off, UtranServiceHoSwit ch:Off, GeranServiceHoSwi tch:Off, Cdma2000HrpdSer viceHoSwitch:Off, Cdma20001xRttSer viceHoSwitch:Off, UlQualityInterRATH oSwitch:Off, InterPlmnHoSwitch: Off, UtranFlashCsfbSwit ch:Off, GeranFlashCsfbSwi tch:Off, ServiceBasedInterF reqHoSwitch:Off, UlQualityInterFreqH oSwitch:Off

IntraFreqCoverHoS witch:On InterFreqCoverHoS witch:On UtranCsfbSwitch:Of f GeranCsfbSwitch:O ff Cdma1xRttCsfbSwit ch:Off UtranServiceHoSwit ch:Off GeranServiceHoSwi tch:Off Cdma2000HrpdSer Engineering Design ENodeBAlgoSwitch viceHoSwitch:Off Cdma20001xRttSer viceHoSwitch:Off UlQualityInterRATH oSwitch:Off InterPlmnHoSwitch: Off UtranFlashCsfbSwit ch:Off GeranFlashCsfbSwi tch:Off ServiceBasedInterF reqHoSwitch:Off UlQualityInterFreqH oSwitch:Off

EutranVoipCapSwit ch, UtranVoipCapSwitc h, GeranVoipCapSwitc h, Cdma1xRttVoipCap Switch, UtranPsHoSwitch, GeranPsHoSwitch, CdmaHrpdNonOtpi misedHoSwitch, CdmaHrpdOptimise dHoSwitch, GeranNaccSwitch, GeranCcoSwitch, UtranSrvccSwitch, GeranSrvccSwitch, Cdma1xRttSrvccSw itch, UtranRedirectSwitc h, GeranRedirectSwitc h, CdmaHrpdRedirect Switch, Cdma1xRttRedirect Switch, BlindHoSwitch

EutranVoipCapSwit ch:On, UtranVoipCapSwitc h:Off, GeranVoipCapSwitc h:Off, Cdma1xRttVoipCap Switch:Off, UtranPsHoSwitch:O ff, GeranPsHoSwitch: Off, CdmaHrpdNonOtpi misedHoSwitch:Off, CdmaHrpdOptimise dHoSwitch:Off, GeranNaccSwitch: Off, GeranCcoSwitch:Of f, UtranSrvccSwitch:O ff, GeranSrvccSwitch: Off, Cdma1xRttSrvccSw itch:Off, UtranRedirectSwitc h:Off, GeranRedirectSwitc h:Off, CdmaHrpdRedirect Switch:Off, Cdma1xRttRedirect Switch:Off,

EutranVoipCapSwit ch:On UtranVoipCapSwitc h:Off GeranVoipCapSwitc h:Off Cdma1xRttVoipCap Switch:Off UtranPsHoSwitch:O ff GeranPsHoSwitch: Off CdmaHrpdNonOtpi misedHoSwitch:Off CdmaHrpdOptimise dHoSwitch:Off GeranNaccSwitch: Engineering Design ENodeBAlgoSwitch Off GeranCcoSwitch:Of f UtranSrvccSwitch:O ff GeranSrvccSwitch: Off Cdma1xRttSrvccSw itch:Off UtranRedirectSwitc h:Off GeranRedirectSwitc h:Off CdmaHrpdRedirect Switch:Off Cdma1xRttRedirect Switch:Off

DlIcicSwitch_OFF_ ENUM, DlIcicDynamicSwitc h_ON_ENUM, DlIcicSwitch_OFF_ DlIcicSwitch_OFF_ Engineering Design ENodeBAlgoSwitch DlIcicStaticSwitch_ ENUM ENUM ON_ENUM, DlIcicReuse3Switch _ON_ENUM

IntraRatEventAnrS witch, IntraRatFastAnrSwit ch, IntraRatAnrAutoDel Switch, UtranEventAnrSwitc h, GeranEventAnrSwit ch, UtranFastAnrSwitch , GeranFastAnrSwitc h, CdmaFastAnrSwitc h, UtranAutoNrtDelete Switch, GeranAutoNrtDelet eSwitch, CdmaAutoNrtDelete Switch, ExtendIntraRatAnrS witch

IntraRatEventAnrS witch:Off, IntraRatFastAnrSwit ch:Off, IntraRatAnrAutoDel Switch:On, UtranEventAnrSwitc h:Off, GeranEventAnrSwit ch:Off, UtranFastAnrSwitch :Off, GeranFastAnrSwitc h:Off, CdmaFastAnrSwitc h:Off, UtranAutoNrtDelete Switch:On, GeranAutoNrtDelet eSwitch:On, CdmaAutoNrtDelete Switch:On, ExtendIntraRatAnrS witch:Off

IntraRatEventAnrS witch: Off IntraRatFastAnrSwit ch: Off IntraRatAnrAutoDel Switch: On UtranEventAnrSwitc h: Off GeranEventAnrSwit ch: Off UtranFastAnrSwitch : Off Engineering Design ENodeBAlgoSwitch GeranFastAnrSwitc h: Off CdmaFastAnrSwitc h: Off UtranAutoNrtDelete Switch: On GeranAutoNrtDelet eSwitch: On CdmaAutoNrtDelete Switch: On ExtendIntraRatAnrS witch:Off

LoadBasedSwitch, GeranFlashRedirect Switch, UranFlashRedirectS witch

LoadBasedSwitch: Off, GeranFlashRedirect Switch:Off, UranFlashRedirectS witch:Off

LoadBasedSwitch: Off GeranFlashRedirect Engineering Design ENodeBAlgoSwitch Switch:Off UranFlashRedirectS witch:Off

IntraFreqMroAlgoS witch:Off, IntraFreqMroSwitch, InterFreqMroAlgoS InterFreqMroSwitch, witch:Off, UtranMroSwitch, UtranMroSwitch:Off, GeranMroSwitch GeranMroSwitch:Of f

IntraFreqMroAlgoS witch:Off InterFreqMroAlgoS witch:Off Engineering Design ENodeBAlgoSwitch UtranMroSwitch:Off GeranMroSwitch:Of f

TpeAlgoSwitch

TpeAlgoSwitch:Off

TpeAlgoSwitch:Off

Engineering Design ENodeBAlgoSwitch

UlIcicIntraSwitch

Uplink Intra-eNB ICIC switch:Off

Uplink Intra-eNB ICIC switch:Off

Engineering Design ENodeBAlgoSwitch

OFF, STATIC, DYNAMIC

OFF(Off)

OFF(Off)

Engineering Design ENodeBAlgoSwitch

OtdoaSwitch

OTDOA switch:Off

OTDOA switch:Off

Default/Recommen ENodeBAlgoSwitch ded Value

UlUuFlowCtrlSwitch

UU flow control switch:Off

UU flow control switch:Off

Engineering Design ENodeBAlgoSwitch

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen ENodeBAlgoSwitch ded Value

SymbolShutdownS Symbol shutdown witch switch:Off

Symbol shutdown switch: Off

Engineering Design ENodeBAlgoSwitch

UTRAN_RIM_SWIT UTRAN RIM CH, Switch:Off, GERAN GERAN_RIM_SWI RIM Switch:Off TCH

UTRAN RIM Switch:Off GERAN RIM Switch:Off

Engineering Design ENodeBAlgoSwitch

NBSLTEPLMNRou ndSwitch, NBSLTERANSharin gSwitch

NBSLTEPLMNRou ndSwitch:Off, NBSLTERANSharin gSwitch:Off

NBSLTEPLMNRou ndSwitch:Off Engineering Design ENodeBAlgoSwitch NBSLTERANSharin gSwitch:Off

UtranFreqLayerMea sSwitch, UtranFreqLayerBlin dSwitch

UtranFreqLayerMea sSwitch:Off, UtranFreqLayerBlin dSwitch:Off

UtranFreqLayerMea sSwitch:Off Engineering Design ENodeBAlgoSwitch UtranFreqLayerBlin dSwitch:Off

1~65535

Default/Recommen LICENSEALMTHD ded Value

50~100

100

100

Default/Recommen LICENSEALMTHD ded Value

1~65535

Default/Recommen LICENSEALMTHD ded Value

49~99

90

90

Default/Recommen LICENSEALMTHD ded Value

1~100

25

25

Engineering Design LicRatio

SHARING, DEDICATE

SHARING(Sharing) SHARING(Sharing) Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

0~100

Engineering Design LicRatio

1~70000

1440

1440

Default/Recommen MRO ded Value

0~100

99

99

Default/Recommen MRO ded Value

0~10000

1000

1000

Default/Recommen MRO ded Value

1~60

Default/Recommen MRO ded Value

0~100

Default/Recommen MRO ded Value

0~100

60

60

Default/Recommen MRO ded Value

-140~-44

-116

-116

Default/Recommen MRO ded Value

-140~-44

-116

-116

Default/Recommen MRO ded Value

0~9

None

None

Engineering Design SimuLoad

0~100

50

50

Default/Recommen SimuLoad ded Value

0~100

50

50

Default/Recommen SimuLoad ded Value

0~50000

500

500

Default/Recommen SimuLoad ded Value

0~50000

5000

5000

Default/Recommen SimuLoad ded Value

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen SimuLoad ded Value

OFF, ON

OFF(Off)

Engineering Design TcpAckCtrlAlgo

0~4294967295

Engineering Design TcpAckCtrlAlgo

1~255

Engineering Design TcpAckCtrlAlgo

0~261120,275943~ 0 307200

Default/Recommen TddFrameOffset ded Value

0~20

Engineering Design TpeAlgo

0~65535

20

20

Engineering Design TpeAlgo

0~65535

80

80

Engineering Design TpeAlgo

0~65535

8080

8080

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~65535

Engineering Design TpeAlgo

0~195

None

None

Transport Planning(Internal planning)

NODETORSCGRP

SGW, X2eNodeB

None

None

Transport Planning(Internal planning)

NODETORSCGRP

NO, YES

None

None

Transport Planning(Internal planning)

NODETORSCGRP

0~127

This parameter must be set to the ID of an S-GW or neighboring eNodeB. If the peer device is an S-GW, set this parameter Transport to a value in the Planning(Internal range of 0 to 127. If planning) the peer device is a neighboring eNodeB, set this parameter to a value in the range of 16 to 79.

NODETORSCGRP

0~7

Default/Recommen NODETORSCGRP ded Value

0~1

Default/Recommen NODETORSCGRP ded Value

0~7

None

None

Default/Recommen NODETORSCGRP ded Value

IP

None

None

Transport Planning(Internal planning)

NODETORSCGRP

0~15

None

None

Transport Planning(Internal planning)

NODETORSCGRP

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

NODETORSCGRP

0~15

Transport Planning(Internal planning)

NODETORSCGRP

PPP, MPGRP, ETH, ETHTRK, TUNNEL

None

None

Transport Planning(Internal planning)

NODETORSCGRP

1~15 characters

None

None

Transport Planning(Internal planning)

SonSecPara

1~99

None

None

Transport Planning(Internal planning)

SonSecPara

1~15 characters

None

None

Transport Planning(Internal planning)

SonSecPara

X2, S1

X2(X2)

None

Transport Planning(Internal planning)

SonSecPara

IKE_V1, IKE_V2

IKE_V2(IKE V2)

IKE_V2(IKE V2)

Transport Planning(Internal planning)

SonSecPara

MAIN, AGGRESSIVE

MAIN(Main Mode)

MAIN(Main Mode)

Transport Planning(Internal planning)

SonSecPara

0~127 characters

None

None

Transport Planning(Internal planning)

SonSecPara

DISABLE, PERIODIC

PERIODIC(Periodic PERIODIC )

Transport Planning(Internal planning)

SonSecPara

10~3600

10

None

Default/Recommen SonSecPara ded Value

3~30

None

Default/Recommen SonSecPara ded Value

3~10

None

Default/Recommen SonSecPara ded Value

DISABLE, PFS_GROUP1, PFS_GROUP2

DISABLE(Disable)

DISABLE

Transport Planning(Internal planning)

SonSecPara

GLOBAL, LOCAL

LOCAL(Local Configuration)

None

Transport Planning(Internal planning)

SonSecPara

30~604800

3600

3600

Default/Recommen SonSecPara ded Value

0,1843200~429496 69120000 7295

None

Default/Recommen SonSecPara ded Value

0~3

None

None

Transport Planning(Internal planning)

SonSecPara

1~15 characters

None

None

Transport Planning(Internal planning)

MME6

Valid IP address

None

None

Transport Planning(Negotiatio MME6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPSec tunnel has Transport already been Planning(Negotiatio MME6 configured to n with the peer) protect the SCTP link set up using the first signaling IPv6 address of the IPv6 MME.

0~15 characters

NULL

None

Transport Planning(Negotiatio MME6 n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio MME6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

This parameter is Transport not required if Planning(Negotiatio MME6 SCTP multi-homing n with the peer) is not supported.

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel that is Transport set up by using the Planning(Negotiatio MME6 second signaling n with the peer) IPv6 address of the IPv6 MME has been configured between the eNodeB and the IPv6 MME.

0~15 characters

NULL

None

Transport Planning(Negotiatio MME6 n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio MME6 n with the peer)

1024~65535

None

None

Transport Planning(Negotiatio MME6 n with the peer)

0~20 characters

NULL

None

Transport Planning(Internal planning)

MME6

0~3

None

Transport Planning(Negotiatio MME6 n with the peer)

Release_R8, Release_R9, Release_R10

Release_R8(Releas None e 8)

Transport Planning(Negotiatio MME6 n with the peer)

0~15

None

None

Transport Planning(Internal planning)

MME

Valid IP address

None

None

Transport Planning(Negotiatio MME n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio MME configured to n with the peer) protect the SCTP link set up using the first signaling IP address of the MME.

0~15 characters

NULL

None

Transport Planning(Negotiatio MME n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio MME n with the peer)

Valid IP address

0.0.0.0

This parameter is required only if SCTP multihoming is supported.

Transport Planning(Negotiatio MME n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio MME configured to n with the peer) protect the SCTP link set up using the first signaling IP address of the MME.

0~15 characters

NULL

None

Transport Planning(Negotiatio MME n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio MME n with the peer)

1024~65535

None

None

Transport Planning(Negotiatio MME n with the peer)

0~20 characters

NULL

None

Transport Planning(Internal planning)

MME

0~3

None

Transport Planning(Negotiatio MME n with the peer)

Release_R8, Release_R9, Release_R10

Release_R8(Releas None e 8)

Transport Planning(Negotiatio MME n with the peer)

0~7

Default/Recommen S1ServIP ded Value

0~1

Default/Recommen S1ServIP ded Value

0~7

None

Default/Recommen S1ServIP ded Value

1~15 characters

None

None

Transport Planning(Internal planning)

S1ServIP

Valid IP address

None

None

Transport Planning(Internal planning)

S1ServIP

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec Transport or an IPSec tunnel Planning(Internal has already been planning) configured to protect the IP path set up using this S1 service IP address.

S1ServIP

Valid IP address

0.0.0.0

None

Transport Planning(Internal planning)

S1ServIP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

S1ServIP

0~3

None

Transport Planning(Internal planning)

S1ServIP

1~15 characters

None

None

Transport Planning(Internal planning)

S1ServIP6

0~7

Default/Recommen S1ServIP6 ded Value

0~1

Default/Recommen S1ServIP6 ded Value

0~7

None

Default/Recommen S1ServIP6 ded Value

Valid IP address

None

None

Transport Planning(Internal planning)

S1ServIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPSec or an IPv6 Transport IPSec tunnel has Planning(Internal already been planning) configured to protect the IPv6 path set up using this S1 service IPv6 address.

S1ServIP6

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

S1ServIP6

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

S1ServIP6

0~3

None

Transport Planning(Internal planning)

S1ServIP6

0~7

Default/Recommen S1SigIP ded Value

0~1

Default/Recommen S1SigIP ded Value

0~7

None

Default/Recommen S1SigIP ded Value

1~15 characters

None

None

Transport Planning(Internal planning)

S1SigIP

Valid IP address

None

None

Transport Planning(Internal planning)

S1SigIP

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Internal configured to planning) protect the SCTP link set up using the second S1 signaling IP address of the eNodeB.

S1SigIP

Valid IP address

0.0.0.0

None

Transport Planning(Internal planning)

S1SigIP

Valid IP address

0.0.0.0

The value 0.0.0.0 is Transport recommended if Planning(Internal SCTP multihoming planning) is not supported.

S1SigIP

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Internal configured to planning) protect the SCTP link set up using the second S1 signaling IP address of the eNodeB.

S1SigIP

Valid IP address

0.0.0.0

None

Transport Planning(Internal planning)

S1SigIP

1024~65535

None

None

Transport Planning(Internal planning)

S1SigIP

10~59999

1000

1000

Default/Recommen S1SigIP ded Value

11~60000

3000

3000

Default/Recommen S1SigIP ded Value

10~59999

1000

1000

Default/Recommen S1SigIP ded Value

1~99

12

12

Default/Recommen S1SigIP ded Value

1~99

25

25

Default/Recommen S1SigIP ded Value

1000~60000

5000

5000

Default/Recommen S1SigIP ded Value

2~254

10

10

Default/Recommen S1SigIP ded Value

1~253

Default/Recommen S1SigIP ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen S1SigIP ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen S1SigIP ded Value

ALDER32, CRC32

CRC32(CRC32)

CRC32(CRC32)

Default/Recommen S1SigIP ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen S1SigIP ded Value

1~254

10

10

Default/Recommen S1SigIP ded Value

10~500

200

200

Default/Recommen S1SigIP ded Value

0~3

None

Transport Planning(Internal planning)

S1SigIP

1~15 characters

None

None

Transport Planning(Internal planning)

S1SigIP6

0~7

Default/Recommen S1SigIP6 ded Value

0~1

Default/Recommen S1SigIP6 ded Value

0~7

None

Default/Recommen S1SigIP6 ded Value

Valid IP address

None

None

Transport Planning(Internal planning)

S1SigIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel has Transport already been Planning(Internal configured to planning) protect the IPv6 SCTP link set up using the first S1 signaling IPv6 address of the eNodeB.

S1SigIP6

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

S1SigIP6

Valid IP address

0:0:0:0:0:0:0:0

This parameter is Transport not required if Planning(Internal SCTP multi-homing planning) is not supported.

S1SigIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel has Transport already been Planning(Internal configured to planning) protect the IPv6 SCTP link set up using the second S1 signaling IPv6 address of the eNodeB.

S1SigIP6

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

S1SigIP6

1024~65535

None

None

Transport Planning(Internal planning)

S1SigIP6

1000~60000

1000

1000

Default/Recommen S1SigIP6 ded Value

1000~60000

3000

3000

Default/Recommen S1SigIP6 ded Value

1000~60000

1000

1000

Default/Recommen S1SigIP6 ded Value

1~99

12

12

Default/Recommen S1SigIP6 ded Value

1~99

25

25

Default/Recommen S1SigIP6 ded Value

1000~60000

5000

5000

Default/Recommen S1SigIP6 ded Value

2~254

10

10

Default/Recommen S1SigIP6 ded Value

1~253

Default/Recommen S1SigIP6 ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen S1SigIP6 ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen S1SigIP6 ded Value

ALDER32, CRC32

CRC32(CRC32)

CRC32(CRC32)

Default/Recommen S1SigIP6 ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen S1SigIP6 ded Value

1~254

10

10

Default/Recommen S1SigIP6 ded Value

0~3

None

Transport Planning(Internal planning)

S1SigIP6

0~127

None

None

Transport Planning(Internal planning)

SGW

Valid IP address

None

None

Transport Planning(Negotiatio SGW n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio SGW configured to n with the peer) protect the IP path set up using the first service IP address of the S-GW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio SGW n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio SGW configured to n with the peer) protect the IP path set up using the second service IP address of the SGW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio SGW n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio SGW configured to n with the peer) protect the IP path set up using the third service IP address of the SGW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio SGW n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio SGW configured to n with the peer) protect the IP path set up using the fourth service IP address of the SGW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW n with the peer)

0~20 characters

NULL

None

Transport Planning(Internal planning)

SGW

0~3

None

Transport Planning(Negotiatio SGW n with the peer)

1~15 characters

None

None

Transport Planning(Internal planning)

SGW6

Valid IP address

None

None

Transport Planning(Negotiatio SGW6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel has Transport already been Planning(Negotiatio SGW6 configured to n with the peer) protect the IPv6 path set up using the first service IPv6 address of the S-GW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio SGW6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel has Transport already been Planning(Negotiatio SGW6 configured to n with the peer) protect the IPv6 path set up using the second service IPv6 address of the IPv6 S-GW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio SGW6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel has Transport already been Planning(Negotiatio SGW6 configured to n with the peer) protect the IPv6 path set up using the third service IPv6 address of the IPv6 S-GW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio SGW6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPsec or an IPv6 IPsec tunnel has Transport already been Planning(Negotiatio SGW6 configured to n with the peer) protect the IPv6 path set up using the fourth service IPv6 address of the IPv6 S-GW.

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

0~15 characters

NULL

None

Transport Planning(Negotiatio SGW6 n with the peer)

0~20 characters

NULL

None

Transport Planning(Internal planning)

SGW6

0~3

None

Transport Planning(Negotiatio SGW6 n with the peer)

0~7

Default/Recommen X2ServIP ded Value

0~1

Default/Recommen X2ServIP ded Value

0~7

None

Default/Recommen X2ServIP ded Value

1~15 characters

None

None

Transport Planning(Internal planning)

X2ServIP

Valid IP address

None

None

Transport Planning(Internal planning)

X2ServIP

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Internal configured to planning) protect the SCTP link set up using the X2 service IP address of the local eNodeB.

X2ServIP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

X2ServIP

Valid IP address

0.0.0.0

0.0.0.0

Transport Planning(Internal planning)

X2ServIP

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2ServIP

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2ServIP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

X2ServIP

0~3

None

Transport Planning(Internal planning)

X2ServIP

0~7

Default/Recommen X2SigIP ded Value

0~1

Default/Recommen X2SigIP ded Value

0~7

None

Default/Recommen X2SigIP ded Value

1~15 characters

None

None

Transport Planning(Internal planning)

X2SigIP

Valid IP address

None

None

Transport Planning(Internal planning)

X2SigIP

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Internal configured to planning) protect the SCTP link set up using the first X2 signaling IP address of the local eNodeB.

X2SigIP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

X2SigIP

Valid IP address

0.0.0.0

0.0.0.0

Transport Planning(Internal planning)

X2SigIP

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP

Valid IP address

0.0.0.0

The value 0.0.0.0 is Transport recommended if Planning(Internal SCTP multihoming planning) is not supported.

X2SigIP

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Internal configured to planning) protect the SCTP link set up using the second X2 signaling IP address of the local eNodeB.

X2SigIP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

X2SigIP

Valid IP address

0.0.0.0

None

Transport Planning(Internal planning)

X2SigIP

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP

1024~65535

36422

36422

Default/Recommen X2SigIP ded Value

10~59999

1000

1000

Default/Recommen X2SigIP ded Value

11~60000

3000

3000

Default/Recommen X2SigIP ded Value

10~59999

1000

1000

Default/Recommen X2SigIP ded Value

1~99

12

12

Default/Recommen X2SigIP ded Value

1~99

25

25

Default/Recommen X2SigIP ded Value

1000~60000

5000

5000

Default/Recommen X2SigIP ded Value

2~254

10

10

Default/Recommen X2SigIP ded Value

1~253

Default/Recommen X2SigIP ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen X2SigIP ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen X2SigIP ded Value

ALDER32, CRC32

CRC32(CRC32)

CRC32(CRC32)

Default/Recommen X2SigIP ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen X2SigIP ded Value

1~254

10

10

Default/Recommen X2SigIP ded Value

10~500

200

200

Default/Recommen X2SigIP ded Value

0~3

None

Transport Planning(Internal planning)

X2SigIP

16~79

None

None

Transport Planning(Internal planning)

X2eNodeB

Valid IP address

None

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel has already been Transport configured to Planning(Negotiatio X2eNodeB protect the SCTP n with the peer) link set up using the first signaling IP address of the neighboring eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

This parameter is required only if SCTP multihoming is supported.

Transport Planning(Negotiatio X2eNodeB n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel has already been Transport configured to Planning(Negotiatio X2eNodeB protect the SCTP n with the peer) link set up using the second signaling IP address of the neighboring eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

1024~65535

36422

36422

Default/Recommen X2eNodeB ded Value

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel Transport has already been Planning(Negotiatio X2eNodeB configured to n with the peer) protect the IP path set up using the first service IP address of the neighboring eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel has already been Transport configured to Planning(Negotiatio X2eNodeB protect the IP path n with the peer) set up using the second service IP address of the neighboring eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel has already been Transport configured to Planning(Negotiatio X2eNodeB protect the IP path n with the peer) set up using the third service IP address of the neighboring eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

Transport Same as the default Planning(Negotiatio X2eNodeB value n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPSec or an IPSec tunnel has already been Transport configured to Planning(Negotiatio X2eNodeB protect the IP path n with the peer) set up using the fourth service IP address of the neighboring eNodeB.

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

Valid IP address

0.0.0.0

Transport Same as the default Planning(Negotiatio X2eNodeB value n with the peer)

000~999

460

This parameter is set as required.

Transport Planning(Negotiatio X2eNodeB n with the peer)

00~99,000~999

20

This parameter is set as required.

Transport Planning(Negotiatio X2eNodeB n with the peer)

0~1048575

Set this parameter to the ID of the neighboring eNodeB. None

Transport Planning(Negotiatio X2eNodeB n with the peer) Transport Planning(Internal planning)

0~20 characters

NULL

X2eNodeB

0~3

None

Transport Planning(Negotiatio X2eNodeB n with the peer)

Release_R8, Release_R9, Release_R10

Release_R10(Relea None se 10)

Transport Planning(Negotiatio X2eNodeB n with the peer)

1~15 characters

None

None

Transport Planning(Internal planning)

X2ServIP6

0~7

Default/Recommen X2ServIP6 ded Value

0~1

Default/Recommen X2ServIP6 ded Value

0~7

None

Default/Recommen X2ServIP6 ded Value

Valid IP address

None

None

Transport Planning(Internal planning)

X2ServIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPSec or an IPv6 IPSec tunnel has Transport already been Planning(Internal configured to planning) protect the IPv6 path set up using the X2 service IPv6 address of the local eNodeB.

X2ServIP6

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

X2ServIP6

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

X2ServIP6

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2ServIP6

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2ServIP6

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

X2ServIP6

0~3

None

Transport Planning(Internal planning)

X2ServIP6

1~15 characters

None

None

Transport Planning(Internal planning)

X2SigIP6

0~7

Default/Recommen X2SigIP6 ded Value

0~1

Default/Recommen X2SigIP6 ded Value

0~7

None

None

Default/Recommen X2SigIP6 ded Value

Valid IP address

None

None

Transport Planning(Internal planning)

X2SigIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec Transport tunnel has already Planning(Internal been configured to planning) protect the SCTP link set up using the first X2 signaling IPv6 address of the local eNodeB.

X2SigIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec tunnel has already Transport been configured to Planning(Internal protect the IPv6 planning) SCTP link set up using the first X2 signaling IPv6 address of the local eNodeB.

X2SigIP6

Valid IP address

0:0:0:0:0:0:0:0

0.0.0.0

Transport Planning(Internal planning)

X2SigIP6

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP6

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP6

Valid IP address

0:0:0:0:0:0:0:0

This parameter is required only if SCTP multihoming is supported.

Transport Planning(Internal planning)

X2SigIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec Transport tunnel has already Planning(Internal been configured to planning) protect the SCTP link set up using the second X2 signaling IPv6 address of the local eNodeB.

X2SigIP6

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec tunnel has already Transport been configured to Planning(Internal protect the IPv6 planning) SCTP link set up using the second X2 signaling IPv6 address of the local eNodeB.

X2SigIP6

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Internal planning)

X2SigIP6

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP6

0~15 characters

NULL

None

Transport Planning(Internal planning)

X2SigIP6

1024~65535

36422

36422

Default/Recommen X2SigIP6 ded Value

1000~60000

1000

1000

Default/Recommen X2SigIP6 ded Value

1000~60000

3000

3000

Default/Recommen X2SigIP6 ded Value

1000~60000

1000

1000

Default/Recommen X2SigIP6 ded Value

1~99

12

12

Default/Recommen X2SigIP6 ded Value

1~99

25

25

Default/Recommen X2SigIP6 ded Value

1000~60000

5000

5000

Default/Recommen X2SigIP6 ded Value

2~254

10

10

Default/Recommen X2SigIP6 ded Value

1~253

Default/Recommen X2SigIP6 ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen X2SigIP6 ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen X2SigIP6 ded Value

ALDER32, CRC32

CRC32(CRC32)

CRC32(CRC32)

Default/Recommen X2SigIP6 ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen X2SigIP6 ded Value

1~254

10

10

Default/Recommen X2SigIP6 ded Value

0~3

None

Transport Planning(Internal planning)

X2SigIP6

1~15 characters

None

None

Transport Planning(Internal planning)

X2eNodeB6

Valid IP address

None

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec tunnel has already Transport been configured to Planning(Negotiatio X2eNodeB6 protect the SCTP n with the peer) link set up using the first signaling IPv6 address of the neighboring IPv6 eNodeB.

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec tunnel has already Transport been configured to Planning(Negotiatio X2eNodeB6 protect the SCTP n with the peer) link set up using the first signaling IPv6 address of the neighboring IPv6 eNodeB.

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

This parameter is required only if SCTP multihoming is supported.

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec tunnel has already Transport been configured to Planning(Negotiatio X2eNodeB6 protect the SCTP n with the peer) link set up using the second signaling IPv6 address of the neighboring IPv6 eNodeB.

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if IPv6 IPSec is not used in the network or an IPv6 IPSec tunnel has already Transport been configured to Planning(Negotiatio X2eNodeB6 protect the SCTP n with the peer) link set up using the second signaling IPv6 address of the neighboring IPv6 eNodeB.

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

1024~65535

36422

36422

Default/Recommen X2eNodeB6 ded Value

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPSec or an IPv6 IPSec tunnel has Transport already been Planning(Negotiatio X2eNodeB6 configured to n with the peer) protect the IPv6 path set up using the first service IPv6 address of the neighboring IPv6 eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPSec or an IPv6 IPSec tunnel has Transport already been Planning(Negotiatio X2eNodeB6 configured to n with the peer) protect the IPv6 path set up using the second service IPv6 address of the neighboring IPv6 eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPSec or an IPv6 IPSec tunnel has Transport already been Planning(Negotiatio X2eNodeB6 configured to n with the peer) protect the IPv6 path set up using the third service IPv6 address of the neighboring IPv6 eNodeB.

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

Transport Same as the default Planning(Negotiatio X2eNodeB6 value n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

DISABLE, ENABLE DISABLE(Disable)

The value DISABLE is recommended if the network does not support IPv6 IPSec or an IPv6 IPSec tunnel has Transport already been Planning(Negotiatio X2eNodeB6 configured to n with the peer) protect the IPv6 path set up using the fourth service IPv6 address of the neighboring IPv6 eNodeB.

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

Transport Same as the default Planning(Negotiatio X2eNodeB6 value n with the peer)

000~999

460

This parameter is set as required.

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

00~99,000~999

20

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

0~1048575

Set this parameter Transport to the ID of the peer Planning(Negotiatio X2eNodeB6 eNodeB. n with the peer) Transport Planning(Internal planning)

0~20 characters

NULL

None

X2eNodeB6

0~3

None

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

Release_R8, Release_R9, Release_R10

Release_R10(Relea None se 10)

Transport Planning(Negotiatio X2eNodeB6 n with the peer)

1~127 characters

None

None

Transport Planning(Internal planning)

CA

1~128 characters

None

None

Transport Planning(Internal planning)

CA

SHA1, SHA256

SHA1(SHA1)

SHA1(SHA1)

Transport Planning(Internal planning)

CA

ESN, MAC, IP

ESN(ESN)

ESN(ESN)

Transport Planning(Internal planning)

CERTREQ

0~32 characters

NULL

None

Transport Planning(Internal planning)

CERTREQ

0~0,2~2 characters NULL

None

Transport Planning(Internal planning)

CERTREQ

0~64 characters

NULL

None

Transport Planning(Internal planning)

CERTREQ

0~64 characters

NULL

None

Transport Planning(Internal planning)

CERTREQ

0~128 characters

NULL

None

Transport Planning(Internal planning)

CERTREQ

0~128 characters

NULL

None

Transport Planning(Internal planning)

CERTREQ

DATA_ENCIPHER MENT, DIGITAL_SIGNATU RE, KEY_AGREEMENT , KEY_ENCIPHERM ENT

DATA_ENCIPHER MENT:1, DIGITAL_SIGNATU RE:1, KEY_AGREEMENT :1, KEY_ENCIPHERM ENT:1

DATA_ENCIPHER MENT:1, DIGITAL_SIGNATU Transport RE:1, Planning(Internal KEY_AGREEMENT planning) :1, KEY_ENCIPHERM ENT:1

CERTREQ

SHA1, MD5, SHA256

SHA1(SHA1)

SHA1(SHA1)

Transport Planning(Internal planning)

CERTREQ

KEYSIZE1024, KEYSIZE2048

Transport KEYSIZE2048(KEY KEYSIZE2048(KEY Planning(Internal SIZE2048) SIZE2048) planning)

CERTREQ

0~128 characters

NULL

None

Transport Planning(Internal planning)

CERTREQ

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio CERTREQ n with the peer)

1~64 characters

None

None

Transport Planning(Internal planning)

CERTMK

0~128 characters

None

None

N/A

CERTMK

0~128 characters

None

None

N/A

CERTMK

0~128 characters

None

None

N/A

CERTMK

0~128 characters

None

None

N/A

CERTMK

0~128 characters

None

None

N/A

CERTMK

IKE, SSL

None

None

Transport Planning(Internal planning)

APPCERT

1~64 characters

None

None

Transport Planning(Internal planning)

APPCERT

0~128 characters

None

None

N/A

APPCERT

0~128 characters

None

None

N/A

APPCERT

0~128 characters

None

None

N/A

APPCERT

0~128 characters

None

None

N/A

APPCERT

0~15 characters

NULL

None

Transport Planning(Internal planning)

APPCERT

0~128 characters

None

None

N/A

APPCERT

NORMALLY, ABNORMALITY, FILENOTEXIST

None

None

N/A

APPCERT

IKE, SSL

None

None

N/A

APPCERT

1~64 characters

None

None

Transport Planning(Internal planning)

CROSSCERT

0~128 characters

None

None

N/A

CROSSCERT

0~128 characters

None

None

N/A

CROSSCERT

0~128 characters

None

None

N/A

CROSSCERT

0~128 characters

None

None

N/A

CROSSCERT

NORMALLY, ABNORMALITY, FILENOTEXIST

None

None

N/A

CROSSCERT

0~128 characters

None

None

N/A

CROSSCERT

1~64 characters

None

None

Transport Planning(Internal planning)

TRUSTCERT

0~128 characters

None

None

N/A

TRUSTCERT

0~128 characters

None

None

N/A

TRUSTCERT

0~128 characters

None

None

N/A

TRUSTCERT

0~128 characters

None

None

N/A

TRUSTCERT

NORMALLY, ABNORMALITY, FILENOTEXIST

None

None

N/A

TRUSTCERT

0~128 characters

None

None

N/A

TRUSTCERT

1~64 characters

None

None

Transport Planning(Internal planning)

CRL

NORMAL, CERTLOSS, CERTDAMAGE, None UNKNOWFORMAT , FAILED

None

N/A

CRL

0~128 characters 0~128 characters

None None

None None

N/A N/A

CRL CRL

0~128 characters

None

None

N/A

CRL

Valid IP address

None

None

Transport Planning(Internal planning)

CRLTSK

0~255 characters

NULL

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

CRLTSK

0~255 characters

NULL

None

CRLTSK

0~65535

389

389

Transport Planning(Internal planning)

CRLTSK

1~64 characters

None

None

Transport Planning(Internal planning)

CRLTSK

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

CRLTSK

8~240

24

24

Transport Planning(Internal planning)

CRLTSK

0~3

None

None

Transport Planning(Internal planning)

CRLTSK

FTP, LDAP

FTP(FTP)

FTP(FTP)

Transport Planning(Internal planning)

CRLTSK

0~255 characters

NULL

None

Transport Planning(Internal planning)

CRLTSK

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Transport Planning(Internal planning)

CERTCHKTSK

1~15

Default/Recommen CERTCHKTSK ded Value

7~180

30

30

Default/Recommen CERTCHKTSK ded Value

PROXY, CMP

PROXY(PROXY)

PROXY(PROXY)

Transport Planning(Internal planning)

CERTCHKTSK

NOVERIFY, ALARM, DISCONNECT

NOVERIFY(No Verifying)

NOVERIFY(No Verifying)

Transport Planning(Internal planning)

CRLPOLICY

3000~4999

None

None

Transport Planning(Internal planning)

ACL

0~127 characters

None

None

Transport Planning(Internal planning)

ACL

3000~3999

None

None

Transport Planning(Internal planning)

ACL6

0~127 characters

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning) Transport Planning(Internal planning)

ACL6

3000~4999

None

None

ACLRULE

1~65535

None

None

ACLRULE

DENY, PERMIT

PERMIT(Permit)

PERMIT(Permit)

Transport Planning(Internal planning)

ACLRULE

IP, ICMP, TCP, UDP, SCTP

None

None

Transport Planning(Internal planning)

ACLRULE

Valid IP address

None

None

Transport Planning(Negotiatio ACLRULE n with the peer)

Valid wildcard of the None IP address

None

Transport Planning(Negotiatio ACLRULE n with the peer)

NO, YES

None

None

Transport Planning(Negotiatio ACLRULE n with the peer)

OP_LT, OP_GT, OP_EQ, OP_NEQ, None OP_RANGE

None

Transport Planning(Internal planning)

ACLRULE

0~65535

None

None

Transport Planning(Internal planning)

ACLRULE

0~65535

None

None

Transport Planning(Internal planning)

ACLRULE

Valid IP address

None

None

Transport Planning(Negotiatio ACLRULE n with the peer)

Valid wildcard of the None IP address

None

Transport Planning(Negotiatio ACLRULE n with the peer)

NO, YES

None

None

Transport Planning(Negotiatio ACLRULE n with the peer)

OP_LT, OP_GT, OP_EQ, OP_NEQ, None OP_RANGE

None

Transport Planning(Internal planning)

ACLRULE

0~65535

None

None

Transport Planning(Internal planning)

ACLRULE

0~65535

None

None

Transport Planning(Internal planning)

ACLRULE

NO, YES

NO(No)

NO(No)

Transport Planning(Negotiatio ACLRULE n with the peer)

0~63

None

None

Transport Planning(Internal planning)

ACLRULE

NO, YES

NO(No)

NO(No)

Transport Planning(Negotiatio ACLRULE n with the peer)

OP_EQ, OP_RANGE

None

None

Transport Planning(Internal planning)

ACLRULE

1~4094

None

None

Transport Planning(Internal planning)

ACLRULE

1~4094

None

None

Transport Planning(Internal planning)

ACLRULE

3000~3999

None

None

Transport Planning(Internal planning)

ACLRULE6

1~65535

None

None

Transport Planning(Internal planning)

ACLRULE6

DENY, PERMIT

PERMIT(Permit)

PERMIT(Permit)

Transport Planning(Internal planning)

ACLRULE6

IP6, TCP, UDP, ICMP6, SCTP

None

None

Transport Planning(Internal planning)

ACLRULE6

Valid IP address

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

0~128

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

NO, YES

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

OP_LT, OP_GT, OP_EQ, OP_NEQ, None OP_RANGE

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

0~65535

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

0~65535

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

0~128

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

NO, YES

None

None

Transport Planning(Negotiatio ACLRULE6 n with the peer)

OP_LT, OP_GT, OP_EQ, OP_NEQ, None OP_RANGE

None

Transport Planning(Internal planning)

ACLRULE6

0~65535

None

None

Transport Planning(Internal planning)

ACLRULE6

0~65535

None

None

Transport Planning(Internal planning)

ACLRULE6

NO, YES

NO(No)

NO(No)

Transport Planning(Negotiatio ACLRULE6 n with the peer)

0~63

None

None

Transport Planning(Internal planning)

ACLRULE6

0~7

Default/Recommen BFDSESSION ded Value

0~1

Default/Recommen BFDSESSION ded Value

0~7

None

None

Transport Planning(Internal planning)

BFDSESSION

0~95

None

None

Transport Planning(Internal planning)

BFDSESSION

Valid IP address

None

None

Transport Planning(Negotiatio BFDSESSION n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio BFDSESSION n with the peer)

SINGLE_HOP, MULTI_HOP

None

None

Transport Planning(Internal planning)

BFDSESSION

10~1000

100

100

Default/Recommen BFDSESSION ded Value

10~1000

100

100

Default/Recommen BFDSESSION ded Value

3~10

Default/Recommen BFDSESSION ded Value

MAINTENANCE, RELIABILITY

RELIABILITY(Relia RELIABILITY(Relia Default/Recommen BFDSESSION bility) bility) ded Value

0~63

48

48

Default/Recommen BFDSESSION ded Value

NO, YES

NO(No)

NO(No)

N/A

BFDSESSION

ADMINDOWN, DOWN, INIT, UP

None

None

N/A

BFDSESSION

DEMAND_MODE, ASYNCHRONOUS None _MODE

None

N/A

BFDSESSION

10~1000

None

None

N/A

BFDSESSION

10~1000

None

None

N/A

BFDSESSION

0~4294967295

None

None

N/A

BFDSESSION

0~4294967295

None

None

N/A

BFDSESSION

0~4294967295

None

None

N/A

BFDSESSION

0~4294967295

None

None

N/A

BFDSESSION

0~4294967295

None

None

N/A

BFDSESSION

0~4294967295

None

None

N/A

BFDSESSION

NO_DIAGNOSTIC, CTRL_DECT_TIME _EXPIRED, ECHO_FUNC_FAIL ED, NEIGHBOR_SIG_S ESSION_DOWN, FORDWARDING_P LANE_RESET, None PATH_DOWN, CONCATENATED_ PATH_DOWN, ADMIN_DOWN, REVERSE_CONCA TENTATED_PATH _DOWN, PEER_ADMIN_DO WN

None

N/A

BFDSESSION

0~15

None

None

N/A

BFDSESSION

DRAFT4, STANDARD

Transport DRAFT4(DRAFT4) DRAFT4(DRAFT4) Planning(Internal planning)

BFDSESSION

DEFAULT, SPECIFIC

DEFAULT(Default) None

Default/Recommen CERTDEPLOY ded Value

0~7

None

Default/Recommen CERTDEPLOY ded Value

0~1

None

Default/Recommen CERTDEPLOY ded Value

0~7

None

Default/Recommen CERTDEPLOY ded Value

1~43 characters

None

Digits 0 to 9 and letters a to z and A to Z are recommended.

Transport Planning(Internal planning)

CFMBNDIP

1~43 characters

None

Digits 0 to 9 and letters a to z and A to Z are recommended.

Transport Planning(Internal planning)

CFMBNDIP

1~8191

None

None

Transport Planning(Negotiatio CFMBNDIP n with the peer)

Valid IP address

None

None

Transport Planning(Internal planning)

CFMBNDIP

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MDNAME value of a CFM MA.

CFMMA

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MANAME value of a CFM MA.

CFMMA

0~7

Default/Recommen CFMMA ded Value

0~1

Default/Recommen CFMMA ded Value Transport Planning(Internal planning) Transport Planning(Internal planning) Transport Planning(Internal planning)

0~7

None

None

CFMMA

NO, YES

YES(Yes)

YES(Yes)

CFMMA

1~4094

None

CFMMA

0~7

Transport Planning(Internal planning)

CFMMA

10ms, 100ms, 1s, 10s, 1min, 10min

1s(1s)

1s(1s)

Default/Recommen CFMMA ded Value

0~32

None

None

N/A

CFMMA

0~64

None

None

N/A

CFMMA

0~4294967295 0~4294967295

None None

None None

N/A N/A

CFMMA CFMMA

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MDNAME value of a CFM MD.

CFMMD

0~7

Default/Recommen CFMMD ded Value

0~4294967295

None

None

N/A

CFMMD

None

None

None

N/A

CFMMD

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MDNAME value of a CFM MEP.

CFMMEP

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MANAME value of a CFM MEP.

CFMMEP

1~8191

None

None

Transport Planning(Internal planning)

CFMMEP

0~7

Default/Recommen CFMMEP ded Value

0~1

Default/Recommen CFMMEP ded Value Transport Planning(Internal planning)

0~7

None

None

CFMMEP

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

CFMMEP

ETH, ETHTRK

None

None

Transport Planning(Internal planning)

CFMMEP

0~5

None

None

Transport Planning(Internal planning)

CFMMEP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

CFMMEP

NO, YES

YES(Yes)

YES(Yes)

N/A

CFMMEP

1~4094

None

None

N/A

CFMMEP

0~7

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

0~4294967295

None

None

N/A

CFMMEP

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MDNAME value of a CFM RMEP.

CFMRMEP

1~43 characters

None

Digits 0 to 9 and letters a to z and A Transport to Z are Planning(Internal recommended for planning) the MANAME value of a CFM RMEP.

CFMRMEP

1~8191

None

None

Transport Planning(Negotiatio CFMRMEP n with the peer)

14 characters

0000-0000-0000

None

Transport Planning(Internal planning)

CFMRMEP

NORMAL, FAULT

None

None

N/A

CFMRMEP

14 characters

None

None

N/A

CFMRMEP

NO, YES

NO(No)

NO(No)

N/A

CFMRMEP

0~4294967295

None

None

N/A

CFMRMEP

0~4294967295

None

None

N/A

CFMRMEP

0~4

None

None

N/A

CFMRMEP

Valid IP address

None

None

N/A

CFMRMEP

TCP, UDP

None

None

Transport Planning(Internal planning)

DBGSVR

22, 23, 67, 68, 80, 319, 320, 443, 500, 1110, 1120, 2700, 3784, 4443, 4500, None 4784, 6000, 6001, 6006, 6007, 17185, 30023, 33003, 45300

None

Transport Planning(Internal planning)

DBGSVR

DISABLE, ENABLE None

None

Transport Planning(Internal planning)

DBGSVR

0~7

Default/Recommen DEVIP ded Value

0~1

Default/Recommen DEVIP ded Value Transport Planning(Internal planning)

0~7

None

None

DEVIP

BASE_BOARD, E1_COVERBOARD , None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

DEVIP

PPP, MPGRP, ETH, ETHTRK, LOOPINT

None

None

Transport Planning(Internal planning)

DEVIP

0~15

None

None

Transport Planning(Internal planning)

DEVIP

Valid IP address

None

None

Transport Planning(Internal planning)

DEVIP

Valid Mask address None

None

Transport Planning(Internal planning)

DEVIP

1~65535

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

DEVIP6

Valid IP address

None

None

DEVIP6

1~128

None

None

Transport Planning(Internal planning)

DEVIP6

IP6_DAD_OK, IP6_DAD_TENTATI VE, IP6_DAD_DUPLIC None ATED, IP6_DAD_UNKNO W

None

N/A

DEVIP6

0~4294967295

None

None

N/A

DEVIP6

0~4294967295

None

None

N/A

DEVIP6

DISABLE, ENABLE DISABLE(Disable)

Transport ENABLE(ENABLE) Planning(Internal planning)

DHCPRELAYSWIT CH

Valid IP address

None

None

Transport Planning(Internal planning)

DHCPSVRIP

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Transport Planning(Negotiatio DHCPSW n with the peer)

IPPRECEDENCE, DSCP

DSCP(DSCP)

DSCP(DSCP)

Default/Recommen DIFPRI ded Value

0~63

46

46

Default/Recommen DIFPRI ded Value

0~63

46

46

Default/Recommen DIFPRI ded Value

0~63

14

14

Default/Recommen DIFPRI ded Value

0~63

46

46

Default/Recommen DIFPRI ded Value

0~63

46

46

Default/Recommen DIFPRI ded Value

HQ, LQ

HQ(High Quality)

HQ(High Quality)

Default/Recommen DIFPRI ded Value

0~100

100

100

Default/Recommen DIFPRI ded Value

0~1000

Default/Recommen DIFPRI ded Value

0~63

26

26

Default/Recommen DIFPRI ded Value

HQ, LQ

HQ(High Quality)

HQ(High Quality)

Default/Recommen DIFPRI ded Value

0~100

100

100

Default/Recommen DIFPRI ded Value

0~1000

Default/Recommen DIFPRI ded Value

0~63

34

34

Default/Recommen DIFPRI ded Value

HQ, LQ

HQ(High Quality)

HQ(High Quality)

Default/Recommen DIFPRI ded Value

0~100

100

100

Default/Recommen DIFPRI ded Value

0~1000

Default/Recommen DIFPRI ded Value

0~63

26

26

Default/Recommen DIFPRI ded Value

HQ, LQ

HQ(High Quality)

HQ(High Quality)

Default/Recommen DIFPRI ded Value

0~100

100

100

Default/Recommen DIFPRI ded Value

0~1000

Default/Recommen DIFPRI ded Value

0~63

46

46

Default/Recommen DIFPRI ded Value

HQ, LQ

HQ(High Quality)

HQ(High Quality)

Default/Recommen DIFPRI ded Value

0~100

100

100

Default/Recommen DIFPRI ded Value

0~1000

Default/Recommen DIFPRI ded Value

0~63

18

18

Default/Recommen DIFPRI ded Value

HQ, LQ

LQ(Low Quality)

LQ(Low Quality)

Default/Recommen DIFPRI ded Value

0~100

30

30

Default/Recommen DIFPRI ded Value

0~1000

100

100

Default/Recommen DIFPRI ded Value

0~63

18

18

Default/Recommen DIFPRI ded Value

HQ, LQ

LQ(Low Quality)

LQ(Low Quality)

Default/Recommen DIFPRI ded Value

0~100

30

30

Default/Recommen DIFPRI ded Value

0~1000

100

100

Default/Recommen DIFPRI ded Value

0~63

10

10

Default/Recommen DIFPRI ded Value

HQ, LQ

LQ(Low Quality)

LQ(Low Quality)

Default/Recommen DIFPRI ded Value

0~100

30

30

Default/Recommen DIFPRI ded Value

0~1000

100

100

Default/Recommen DIFPRI ded Value

0~63

Default/Recommen DIFPRI ded Value

HQ, LQ

LQ(Low Quality)

LQ(Low Quality)

Default/Recommen DIFPRI ded Value

0~100

30

30

Default/Recommen DIFPRI ded Value

0~1000

100

100

Default/Recommen DIFPRI ded Value

OFF, ON

ON(On)

ON(On)

Engineering Design DLITFCALG

OFF, ON

ON(On)

ON(On)

Engineering Design DLITFCALG

0~7

None

Default/Recommen DOT1X ded Value

0~1

None

Default/Recommen DOT1X ded Value

0~7

None

None

Transport Planning(Internal planning)

DOT1X

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

DOT1X

0~5

None

None

Transport Planning(Internal planning)

DOT1X

EAP-TLS

Transport EAP-TLS(EAP-TLS EAP-TLS(EAP-TLS Planning(Internal authentic method) authentic method) planning)

DOT1X

0~4294967295

None

None

N/A

DOT1X

0~4294967295

None

None

N/A

DOT1X

NULL, LIC_OFF, NOTIFY_FAIL, NO_CERT, PORT_DOWN

None

None

N/A

DOT1X

0~4294967295

None

None

N/A

DOT1X

UNAUTHENTICAT ED, AUTHENTICATING , AUTHENTIC_SUC None CEED, AUTHENTIC_FAIL, DHCP_AUTHENTI CATING

None

N/A

DOT1X

0~4294967295

None

None

N/A

DOT1X

0~4294967295

None

None

N/A

DOT1X

0~63

None

Transport Planning(Internal planning)

DSCPMAP

0~7

None

Transport Planning(Internal planning)

DSCPMAP

0~7

Default/Recommen E1T1 ded Value

0~1

Default/Recommen E1T1 ded Value

0~7

None

None

Transport Planning(Internal planning)

E1T1

0~7,255

255

None

Transport Planning(Internal planning)

E1T1

ALLPORT, SINGLEPORT

Transport ALLPORT(All Ports) ALLPORT(All Ports) Planning(Internal planning)

E1T1

E1_UNBA, E1_BA, E1_UNBA(E1 T1 Unbalance)

E1_UNBA(E1 Unbalance)

Transport Planning(Internal planning)

E1T1

E1_DOUBLE_FRA ME, E1_CRC4_MULTI_ FRAME, None T1_SUPER_FRAM E, T1_EXTENDED_S UPER_FRAME

E1_CRC4_MULTI_ Transport FRAME(E1 CRC4 Planning(Internal Multiple Frames) planning)

E1T1

HDB3, AMI, B8ZS

None

If an E1/T1 port is carried over IP, the Transport AMI line coding Planning(Internal mode is not planning) recommended.

E1T1

MASTER, SLAVE

SLAVE(Slave Mode)

SLAVE(Slave Mode)

Default/Recommen E1T1 ded Value

OK, LOCAL_LOOP, REMOTE_LOOP, PAYLOAD_LOOP, SINGLE_CH_LOO P, LOS, AIS, LFA, None RA, LMFA, SLIP, OTHERS, BACKUP, PHYSICAL_LOOP

None

N/A

E1T1

EXECUTELINKTES TFlAG_0, EXECUTELINKTES None TFlAG_1, EXECUTELINKTES TFlAG_2

None

N/A

E1T1

NO, YES

None

None

N/A

E1T1

0~720

None

None

N/A

E1T1

BASE_BOARD, None E1_COVERBOARD

None

Transport Planning(Internal planning)

E1T1

E1_UNBA, E1_BA, None T1, UNKNOWN

None

N/A

E1T1

E1_DOUBLE_FRA ME, E1_CRC4_MULTI_ FRAME, T1_SUPER_FRAM E, None T1_EXTENDED_S UPER_FRAME, E1_MODIFY_CRC4 _MULTIFRAME, UNKNOWN

None

N/A

E1T1

HDB3, AMI, B8ZS, UNKNOWN

None

None

N/A

E1T1

1E-3, 1E-4, 1E-5, 1E-6

1E-5(1E-5)

1E-5(1E-5)

Default/Recommen E1T1BER ded Value

0~7

Default/Recommen ETHOAM3AH ded Value

0~1

Default/Recommen ETHOAM3AH ded Value

0~7

None

None

Transport Planning(Internal planning)

ETHOAM3AH

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

ETHOAM3AH

ETH

None

None

Transport Planning(Internal planning)

ETHOAM3AH

0~5

None

None

Transport Planning(Internal planning)

ETHOAM3AH

PASSIVE, ACTIVE

ACTIVE(Active Mode)

ACTIVE(Active Mode)

Default/Recommen ETHOAM3AH ded Value

10,20,50,100,200,5 1000 00,1000

1000

Default/Recommen ETHOAM3AH ded Value

64~1518

128

128

Default/Recommen ETHOAM3AH ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen ETHOAM3AH ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen ETHOAM3AH ded Value Default/Recommen ETHOAM3AH ded Value

1~60

1~65535

Default/Recommen ETHOAM3AH ded Value

10~900

60

60

Default/Recommen ETHOAM3AH ded Value

1~900

Default/Recommen ETHOAM3AH ded Value

OAM3AH_SESSIO N_IDLE, OAM3AH_SESSIO N_DISCOVER, OAM3AH_SESSIO None N_DETECT, OAM3AH_SESSIO N_LB_LOCAL, OAM3AH_SESSIO N_LB_REMOTE

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~4294967295

None

None

N/A

ETHOAM3AH

0~7

Default/Recommen ETHPORT ded Value

0~1

Default/Recommen ETHPORT ded Value

0~7

None

None

Transport Planning(Internal planning)

ETHPORT

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

ETHPORT

0~5

None

None

Transport Planning(Internal planning)

ETHPORT

COPPER, FIBER, AUTO

None

If an optical fiber is used for transmission, set this parameter to Transport FIBER. Planning(Internal If an electrical cable planning) is used for transmission, set this parameter to COPPER.

ETHPORT

46~1800

1500

1500

Default/Recommen ETHPORT ded Value

10M, 100M, 1000M, AUTO(Automatic AUTO Negotiation)

AUTO(Automatic Negotiation)

Default/Recommen ETHPORT ded Value

FULL, AUTO

FULL(Full Duplex)

AUTO(Automatic Negotiation)

Default/Recommen ETHPORT ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen ETHPORT ded Value

CLOSE, OPEN

OPEN(Open)

OPEN(Open)

Default/Recommen ETHPORT ded Value

0~100

10

10

Default/Recommen ETHPORT ded Value

0~100

Default/Recommen ETHPORT ded Value

14 characters

None

None

N/A

ETHPORT

UP, DOWN

None

None

N/A

ETHPORT

NOLOOP, REMOTE, LOCAL, None UNKNOWN

None

N/A

ETHPORT

NO, YES

None

None

N/A

ETHPORT

DISABLE, ENABLE None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

0~10

None

None

N/A

ETHPORT

0~4294967295

None

None

N/A

ETHPORT

Valid IP address

None

None

N/A

ETHPORT

FORCE, AUTO

None

None

N/A

ETHPORT

FORCE, AUTO

None

None

N/A

ETHPORT

10M, 100M, 1000M, None AUTO

None

N/A

ETHPORT

HALF, FULL, AUTO None

None

N/A

ETHPORT

FORCE, AUTO, UNKNOWN

None

None

N/A

ETHPORT

10M, 100M, 1000M, None AUTO, UNKNOWN

None

N/A

ETHPORT

HALF, FULL, None AUTO, UNKNOWN

None

N/A

ETHPORT

UP, DOWN

None

None

N/A

ETHPORT

0~7

Default/Recommen ETHTRK ded Value

0~1

Default/Recommen ETHTRK ded Value

0~7

None

None

Transport Planning(Internal planning)

ETHTRK

0~2

Default/Recommen ETHTRK ded Value

DISABLE, ENABLE

ENABLE(Enable LACP)

ENABLE(Enable LACP)

Default/Recommen ETHTRK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen ETHTRK ded Value

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

ETHTRK

46~1800

1500

1500

Default/Recommen ETHTRK ded Value

UP, DOWN

None

None

N/A

ETHTRK

14 characters

None

None

N/A

ETHTRK

14 characters

None

None

N/A

ETHTRK

0~2

None

None

N/A

ETHTRK

0~7 characters

None

None

N/A

ETHTRK

0~2

None

None

N/A

ETHTRK

0~7 characters

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

0~4294967295

None

None

N/A

ETHTRK

Valid IP address

None

None

N/A

ETHTRK

0~7

Default/Recommen ETHTRKLNK ded Value

0~1

Default/Recommen ETHTRKLNK ded Value

0~7

None

None

Transport Planning(Internal planning)

ETHTRKLNK

0~2

Transport Planning(Internal planning)

ETHTRKLNK

0~5

None

None

Transport Planning(Internal planning)

ETHTRKLNK

0~255

255

255

Default/Recommen ETHTRKLNK ded Value

NO, YES

None

None

Transport Planning(Internal planning)

ETHTRKLNK

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

ETHTRKLNK

UP, DOWN

None

None

N/A

ETHTRKLNK

14 characters

None

None

N/A

ETHTRKLNK

SHORT, LONG, NULL

None

None

N/A

ETHTRKLNK

SHORT, LONG, NULL

None

None

N/A

ETHTRKLNK

0~4294967295

None

None

N/A

ETHTRKLNK

0~4294967295

None

None

N/A

ETHTRKLNK

10~254

None

None

Transport Planning(Internal planning)

EXTUDT

0~39

None

None

Transport Planning(Internal planning)

EXTUDT

0~39

None

None

Transport Planning(Internal planning)

EXTUDTPARAGRP

0~63

None

None

Transport Planning(Internal planning)

EXTUDTPARAGRP

0~100

None

Transport Planning(Internal planning)

EXTUDTPARAGRP

HQ, LQ

None

None

Transport Planning(Internal planning)

EXTUDTPARAGRP

0~100

None

None

Transport Planning(Internal planning)

EXTUDTPARAGRP

0~1000

None

None

Transport Planning(Internal planning)

EXTUDTPARAGRP

ARP, ICMP, TCP, SYN, UDP

None

None

Transport Planning(Internal planning)

FLOODDEFEND

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Internal planning)

FLOODDEFEND

1~4096

None

If FLDTYPE is set to ARP or SYN, the recommended value is 64. If FLDTYPE is set to Transport ICMP, the Planning(Internal recommended planning) value is 128. If FLDTYPE is set to TCP or UDP, the recommended value is 2048.

FLOODDEFEND

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Internal planning)

FLOODDEFEND

1~4096

None

If FLDTYPE is set to ARP or SYN, the recommended value is 32. If FLDTYPE is set to Transport ICMP, the Planning(Internal recommended planning) value is 64. If FLDTYPE is set to TCP or UDP, the recommended value is 1024.

FLOODDEFEND

0~4294967295

None

None

N/A

FLOODDEFEND

0~4294967295

None

None

N/A

FLOODDEFEND

DISABLE, ENABLE DISABLE(Disable)

None

Engineering Design GTRANSPARA

SINGLE_RATE, DUAL_RATE

SINGLE_RATE(Sin None gle Rate)

Engineering Design GTRANSPARA

0~1200

30

None

Engineering Design GTRANSPARA

0~31 characters

NULL

None

Transport Planning(Negotiatio IKECFG n with the peer)

0,20~28800

Default/Recommen IKECFG ded Value

0,60~28800

Default/Recommen IKECFG ded Value

0~63

48

None

Transport Planning(Internal planning) N/A

IKECFG

0~7

None

IKECFG

0~1

None

None

N/A

IKECFG

0~7

None

None

N/A

IKECFG

1~15 characters

None

None

Transport Planning(Internal planning)

IKEPEER

1~99

None

None

Transport Planning(Internal planning)

IKEPEER

IKE_V1, IKE_V2

IKE_V2(IKE V2)

IKE_V2(IKE_V2)

Transport Planning(Internal planning)

IKEPEER

MAIN, AGGRESSIVE

MAIN(Main Mode)

MAIN(Main Mode)

Transport Planning(Internal planning)

IKEPEER

IP, FQDN

None

None

Transport Planning(Internal planning)

IKEPEER

Valid IP address

None

None

Transport Planning(Negotiatio IKEPEER n with the peer)

0~31 characters

None

None

Transport Planning(Internal planning)

IKEPEER

0~127 characters

None

None

Transport Planning(Internal planning)

IKEPEER

DISABLE, PERIODIC

Transport PERIODIC(Periodic PERIODIC(Periodic Planning(Internal ) ) planning)

IKEPEER

10~3600

10

10

Default/Recommen IKEPEER ded Value

3~30

Default/Recommen IKEPEER ded Value

3~10

Default/Recommen IKEPEER ded Value

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio IKEPEER n with the peer)

0~7

None

N/A

IKEPEER

0~1

None

N/A

IKEPEER

0~7

None

N/A

IKEPEER

1~15 characters

None

None

Transport Planning(Internal planning)

IKEPEER6

1~99

None

None

Transport Planning(Internal planning)

IKEPEER6

IKE_V1, IKE_V2

IKE_V2(IKE V2)

IKE_V2(IKE V2)

Transport Planning(Internal planning)

IKEPEER6

MAIN, AGGRESSIVE

MAIN(Main Mode)

MAIN(Main Mode)

Transport Planning(Negotiatio IKEPEER6 n with the peer)

FQDN, IPV6

None

None

Transport Planning(Internal planning)

IKEPEER6

Valid IP address

None

None

Transport Planning(Negotiatio IKEPEER6 n with the peer)

0~31 characters

None

None

Transport Planning(Internal planning)

IKEPEER6

0~127 characters

None

None

Transport Planning(Internal planning)

IKEPEER6

DISABLE, PERIODIC

Transport PERIODIC(Periodic PERIODIC(Periodic Planning(Internal ) ) planning)

IKEPEER6

10~3600

10

10

Default/Recommen IKEPEER6 ded Value

3~30

Default/Recommen IKEPEER6 ded Value

3~10

Default/Recommen IKEPEER6 ded Value

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio IKEPEER6 n with the peer)

0~7

None

N/A

IKEPEER6

0~1

None

N/A

IKEPEER6

0~7

None

N/A

IKEPEER6

1~99

None

None

Transport Planning(Internal planning)

IKEPROPOSAL

DES, 3DES, AES128, AES192, AES256

AES128(AES128)

AES128(AES128)

Transport Planning(Internal planning)

IKEPROPOSAL

MD5, SHA1, AES_XCBC_96

SHA1(SHA1)

SHA1(SHA1)

Transport Planning(Internal planning)

IKEPROPOSAL

Transport PRE_SHARED_KE PRE_SHARED_KE PRE_SHARED_KE Planning(Internal Y, IKE_RSA_SIG Y(Pre-shared Key) Y(Pre-shared Key) planning)

IKEPROPOSAL

DH_GROUP1, DH_GROUP2, DH_GROUP14, DH_GROUP15

DH_GROUP2(1024- DH_GROUP2(1024- Transport bit Diffie-Hellman bit Diffie-Hellman Planning(Internal Group) Group) planning)

IKEPROPOSAL

60~604800

86400

86400

Default/Recommen IKEPROPOSAL ded Value

HMAC_MD5, HMAC_SHA1, AES128_XCBC

HMAC_SHA1(HMA HMAC_SHA1(HMA Default/Recommen IKEPROPOSAL C_SHA1) C_SHA1) ded Value

0~7

None

N/A

IKEPROPOSAL

0~1

None

N/A

IKEPROPOSAL

0~7

None

N/A

IKEPROPOSAL

0~7

Default/Recommen IP2RSCGRP ded Value

0~1

Default/Recommen IP2RSCGRP ded Value

0~7

None

None

Transport Planning(Internal planning)

IP2RSCGRP

0~15

Transport Planning(Internal planning)

IP2RSCGRP

Valid IP address

None

None

Transport Planning(Negotiatio IP2RSCGRP n with the peer)

Valid Mask address None

None

Transport Planning(Internal planning)

IP2RSCGRP

IP

IP(IP)

None

Transport Planning(Internal planning)

IP2RSCGRP

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

IP2RSCGRP

PPP, MPGRP, ETH, ETHTRK, TUNNEL

None

None

Transport Planning(Internal planning)

IP2RSCGRP

0~15

Transport Planning(Internal planning)

IP2RSCGRP

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Internal planning)

IPGUARD

10~1000

120

None

Default/Recommen IPGUARD ded Value

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Internal planning)

IPGUARD

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Internal planning)

IPGUARD

20~200000

2000

None

Default/Recommen IPGUARD ded Value

DISABLE, ENABLE DISABLE(Disable)

None

Transport Planning(Internal planning)

IPGUARD

1~100000

100

None

Default/Recommen IPGUARD ded Value

PPP, MPGRP, ETH, ETHTRK, LOOPINT

None

None

N/A

IPGUARD

0~15 14 characters

None None

None None

N/A N/A

IPGUARD IPGUARD

14 characters

None

None

N/A

IPGUARD

0~4294967295

None

None

N/A

IPGUARD

IPV4, ARP, RARP, IPV6, 802_1X, None LLDP, 1588V2, CFM, LACP, 3AH

None

N/A

IPGUARD

Valid IP address

None

None

N/A

IPGUARD

Valid IP address

None

None

N/A

IPGUARD

ICMP, TCP, UDP, SCTP

None

None

N/A

IPGUARD

0~4294967295

None

None

N/A

IPGUARD

0~4294967295

None

None

N/A

IPGUARD

0~200 characters

None

None

N/A Transport Planning(Internal planning) Transport Planning(Internal planning)

IPGUARD

1~65535

None

None

IPITF6

NORMAL, VLAN

NORMAL(Normal)

NORMAL(Normal)

IPITF6

0~7

Default/Recommen IPITF6 ded Value

0~1

Default/Recommen IPITF6 ded Value

6~7

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

IPITF6

BASE_BOARD

None

None

IPITF6

ETH, TRUNK, LOOPIF

None

None

Transport Planning(Internal planning)

IPITF6

0~5

None

None

Transport Planning(Internal planning)

IPITF6

1~4094

None

None

Transport Planning(Internal planning)

IPITF6

1280~1800

1500

None

Default/Recommen IPITF6 ded Value

UP, DOWN

None

None

N/A

IPITF6

Valid IP address

None

None

N/A

IPITF6

0~8

None

None

N/A

IPITF6

Valid IP address

None

None

N/A

IPITF6

0~8

None

None

N/A

IPITF6

Valid IP address

None

None

N/A

IPITF6

DISABLE, ENABLE None

None

N/A

IPITF6

0~4294967295

None

None

N/A

IPITF6

0~4294967295

None

None

N/A

IPITF6

0~4294967295

None

None

N/A

IPITF6

DISABLE, ENABLE None

None

N/A

IPITF6

DISABLE, ENABLE None

None

N/A

IPITF6

0~65535

None

None

Transport Planning(Internal planning)

IPPATH

0~7

Default/Recommen IPPATH ded Value

0~1

Default/Recommen IPPATH ded Value

0~7

None

None

Transport Planning(Internal planning)

IPPATH

PPP, MPGRP, ETH, ETHTRK, TUNNEL

None

None

Transport Planning(Internal planning)

IPPATH

0~15

Transport Planning(Internal planning)

IPPATH

QOS, ANY

ANY(ANY)

It is recommended that IP Path be set to QOS in a Multiple Spanning Tree Protocol (MSTP) Default/Recommen IPPATH network. In other ded Value scenarios, it is recommended that this parameter is set to ANY.

0~63

None

None

Transport Planning(Internal planning)

IPPATH

Valid IP address

None

None

Transport Planning(Negotiatio IPPATH n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio IPPATH n with the peer)

0~79

None

If the IP path belongs to the S1 interface, this parameter is set 0. If the IP path belongs to the X2 interface, this parameter is set from 16 to 79.

Transport Planning(Internal planning)

IPPATH

HQ, LQ

HQ(High Quality)

HQ(High Quality)

Default/Recommen IPPATH ded Value

S1, X2

None

S1(S1)

Transport Planning(Internal planning)

IPPATH

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen IPPATH ded Value

0~4294967294

None

None

N/A

IPPATH

0~4294967294

None

None

N/A

IPPATH

0~4294967294

None

None

N/A

IPPATH

0~4294967294

None

None

N/A

IPPATH

0~4294967295

None

None

N/A

IPPATH

0~4294967295

None

None

N/A

IPPATH

NORMAL, FAULT, CHECK_DISABLE D

None

None

N/A

IPPATH

0~15

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

IPPATH

0~47 characters

NULL

None

IPPATH

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

IPPATH

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen IPPATH ded Value

0~65535

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning) Transport Planning(Internal planning) Transport Planning(Internal planning)

IPPATH6

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

IPPATH6

0~15

None

IPPATH6

1~65535

None

None

IPPATH6

QOS, ANY

None

None

Transport Planning(Internal planning)

IPPATH6

0~63

None

None

Transport Planning(Internal planning)

IPPATH6

Valid IP address

None

None

Transport Planning(Negotiatio IPPATH6 n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio IPPATH6 n with the peer)

0~79

None

If the IPv6 path belongs to the S1 interface, this parameter is set 0. If the IPv6 path belongs to the X2 interface, this parameter is set from 16 to 79.

Transport Planning(Internal planning)

IPPATH6

S1, X2

None

None

Transport Planning(Internal planning)

IPPATH6

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

IPPATH6

0~4294967295

None

None

N/A

IPPATH6

0~4294967295

None

None

N/A

IPPATH6

0~4294967295

None

None

N/A

IPPATH6

0~4294967295

None

None

N/A

IPPATH6

0~4294967295

None

None

N/A

IPPATH6

0~4294967295

None

None

N/A

IPPATH6

NORMAL, FAULT, CHECK_DISABLE D

None

None

N/A

IPPATH6

0~47 characters

NULL

None

Transport Planning(Internal planning)

IPPATH6

Valid IP address

None

None

Transport Planning(Negotiatio IPPATHRT n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio IPPATHRT n with the peer)

HQ, LQ

None

None

Transport Planning(Internal planning)

IPPATHRT

Valid IP address

None

None

Transport Planning(Internal planning)

IPPATHRT

0~65535

None

None

Transport Planning(Internal planning)

IPPMSESSION

Valid IP address

None

None

Transport Planning(Negotiatio IPPMSESSION n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio IPPMSESSION n with the peer)

0~63

None

None

Transport Planning(Internal planning)

IPPMSESSION

UP, BIDIR

UP(Uplink)

UP(Uplink)

Transport Planning(Internal planning)

IPPMSESSION

0~10000

None

None

N/A

IPPMSESSION

-10000~10000

None

None

N/A

IPPMSESSION

-10000~10000

None

None

N/A

IPPMSESSION

0~1000

None

None

N/A

IPPMSESSION

0~1000

None

None

N/A

IPPMSESSION

IDLE, ACTING, PMUP, DEACTING, None UNKNOWN

None

N/A

IPPMSESSION

IDLE, ACTING, PMUP, DEACTING, None UNKNOWN

None

N/A

IPPMSESSION

FOUR_TUPLE, THREE_TUPLE

FOUR_TUPLE(FO UR_TUPLE)

FOUR_TUPLE(FO UR_TUPLE)

Default/Recommen IPPMSESSION ded Value

NO, YES

NO(No)

NO(No)

Default/Recommen IPPMSESSION ded Value

0~65535

None

None

Transport Planning(Internal planning)

IPPMSESSION

NO, YES

None

None

N/A

IPPMSESSION

0~4294967295

None

None

N/A

IPPMSESSION

0~4294967295

None

None

N/A

IPPMSESSION

None

None

None

N/A

IPPMSESSION

NO, YES

None

None

N/A

IPPMSESSION

0~4294967295

None

None

N/A

IPPMSESSION

0~4294967295

None

None

N/A

IPPMSESSION

None

None

None

N/A

IPPMSESSION

IPPMVER_V1, IPPMVER_V2

None

None

N/A

IPPMSESSION

0~7

Default/Recommen IPRT ded Value

0~1

Default/Recommen IPRT ded Value

0~7

None

None

Transport Planning(Internal planning)

IPRT

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

IPRT

PPP, MPGRP, TUNNEL

PPP(PPP Link)

None

Transport Planning(Internal planning)

IPRT

0~15

Transport Planning(Internal planning)

IPRT

NEXTHOP, IF

None

None

Transport Planning(Internal planning)

IPRT

Valid IP address

None

None

Transport Planning(Negotiatio IPRT n with the peer)

Valid Mask address None

None

Transport Planning(Internal planning)

IPRT

Valid IP address

None

Transport Planning(Internal planning)

IPRT

1~255

60

60

Transport Planning(Internal planning)

IPRT

STATICHOST, STATICGATEWAY, None HOST, GATEWAY

None

N/A

IPRT

0~47 characters

NULL

None

Transport Planning(Internal planning)

IPRT

PPP, MPGRP, ETH, ETHTRK, LOOPINT, VI, TUNNEL

None

None

N/A

IPRT

0~32

None

None

N/A

IPRT

Valid IP address

None

None

Transport Planning(Negotiatio IPRT6 n with the peer)

0~128

None

None

Transport Planning(Internal planning)

IPRT6

NEXTHOP

NEXTHOP(Next Hop)

NEXTHOP(Next Hop)

Transport Planning(Internal planning)

IPRT6

IPADDR6_TYPE_G LOBAL_UNICAST, None IPADDR6_TYPE_LI NK_LOCAL

None

Transport Planning(Internal planning)

IPRT6

Valid IP address

None

None

Transport Planning(Internal planning)

IPRT6

1~65535

None

Transport Planning(Internal planning)

IPRT6

1~255

60

60

Transport Planning(Internal planning)

IPRT6

STATICHOST, STATICGATEWAY, None HOST, GATEWAY

None

N/A

IPRT6

0~47 characters

NULL

None

Transport Planning(Internal planning)

IPRT6

0~7

Default/Recommen IPSECBIND ded Value

0~1

Default/Recommen IPSECBIND ded Value

0~7

None

None

Transport Planning(Internal planning)

IPSECBIND

BASE_BOARD, ETH_COVERBOAR None D

None

Transport Planning(Internal planning)

IPSECBIND

ETH, ETHTRK

None

None

Transport Planning(Internal planning)

IPSECBIND

0~5

None

None

Transport Planning(Internal planning)

IPSECBIND

1~15 characters

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

IPSECBIND

1~65535

None

None

IPSECBIND6

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECBIND6

0~49

None

None

Transport Planning(Internal planning)

IPSECDTNL

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECDTNL

1~10000

None

None

Transport Planning(Internal planning)

IPSECDTNL

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECDTNL

1~10000

None

None

Transport Planning(Internal planning)

IPSECDTNL

0~95

None

None

Transport Planning(Internal planning)

IPSECDTNL

0~95

None

None

Transport Planning(Internal planning)

IPSECDTNL

MASTER, SLAVE

None

None

N/A

IPSECDTNL

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPOLICY

1~10000

None

None

Transport Planning(Internal planning)

IPSECPOLICY

3000~3999

None

None

Transport Planning(Internal planning)

IPSECPOLICY

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPOLICY

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPOLICY

DISABLE, PFS_GROUP1, PFS_GROUP2

DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

IPSECPOLICY

GLOBAL, LOCAL

LOCAL(Local Configuration)

LOCAL(Local Configuration)

Transport Planning(Internal planning)

IPSECPOLICY

30~604800

3600

3600

Default/Recommen IPSECPOLICY ded Value

0,1843200~429496 69120000 7295

69120000

Default/Recommen IPSECPOLICY ded Value

0~7

None

N/A

IPSECPOLICY

0~1

None

N/A

IPSECPOLICY

0~7

None

N/A

IPSECPOLICY

WND_DISABLE, WND_32, WND_64, WND_128, WND_256, WND_512, WND_1024, WND_2048, WND_4096

WND_DISABLE(0) None

Default/Recommen IPSECPOLICY ded Value

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

1~10000

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

IPV4, IPV6

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

3000~3999

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

3000~3999

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPOLICY6

DISABLE, PFS_GROUP1, PFS_GROUP2

DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

IPSECPOLICY6

GLOBAL, LOCAL

LOCAL(Local Configuration)

LOCAL(Local Configuration)

Transport Planning(Internal planning)

IPSECPOLICY6

30~604800

3600

3600

Default/Recommen IPSECPOLICY6 ded Value

0,1843200~429496 69120000 7295

69120000

Default/Recommen IPSECPOLICY6 ded Value

0~7

None

N/A

IPSECPOLICY6

0~1

None

N/A

IPSECPOLICY6

0~7

None

N/A

IPSECPOLICY6

1~15 characters

None

None

Transport Planning(Internal planning)

IPSECPROPOSAL

TUNNEL, TRANSPORT

TUNNEL(Tunnel)

TUNNEL(Tunnel)

Default/Recommen IPSECPROPOSAL ded Value

Transport AH, ESP, AH_ESP ESP(ESP Protocol) ESP(ESP Protocol) Planning(Internal planning)

IPSECPROPOSAL

MD5, SHA1, AESXCBC-MAC-96, SHA256

SHA1(SHA1)

SHA1(SHA1)

Transport Planning(Internal planning)

IPSECPROPOSAL

NULL, MD5, SHA1, AES-XCBC-MAC- SHA1(SHA1) 96, SHA256

SHA1(SHA1)

Transport Planning(Internal planning)

IPSECPROPOSAL

NULL, DES, 3DES, AES128, AES192, AES128(AES128) AES256

AES128(AES128)

Transport Planning(Internal planning)

IPSECPROPOSAL

0~7

None

N/A

IPSECPROPOSAL

0~1

None

N/A

IPSECPROPOSAL

0~7

None

N/A

IPSECPROPOSAL

DISABLE, ENABLE None

None

N/A

LOCALETHPORT

UP, DOWN

None

None

N/A

LOCALETHPORT

0~4294967295

None

None

N/A

LOCALETHPORT

0~4294967295

None

None

N/A

LOCALETHPORT

0~4294967295

None

None

N/A

LOCALETHPORT

0~4294967295

None

None

N/A

LOCALETHPORT

Valid IP address

192.168.0.49

Planned IP address Transport for local Planning(Internal maintenance on a planning) board

LOCALIP

Valid Mask address 255.255.255.0

Planned subnet Transport mask of the local Planning(Internal maintenance planning) channel on a board

LOCALIP

Valid IP address

FE80:0:0:0:2315:E6 None 2F:526:4623

Transport Planning(Internal planning)

LOCALIP6

1~128

64

None

Transport Planning(Internal planning)

LOCALIP6

IP6_DAD_OK, IP6_DAD_TENTATI VE, IP6_DAD_DUPLIC None ATED, IP6_DAD_UNKNO W

None

N/A

LOCALIP6

0~4294967295

None

None

N/A

LOCALIP6

0~4294967295

None

None

N/A

LOCALIP6

0~7

Default/Recommen LR ded Value

0~1

Default/Recommen LR ded Value

0~7

None

None

Transport Planning(Internal planning)

LR

MPGRP, ETH, None ETHTRK, TUNNEL

None

Transport Planning(Internal planning)

LR

0~5

None

None

Transport Planning(Internal planning)

LR

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Transport Planning(Internal planning)

LR

32~1000000

None

None

Transport Planning(Internal planning)

LR

32~1000000

None

None

Transport Planning(Internal planning)

LR

0~1000000

None

None

Transport Planning(Internal planning)

LR

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

LR

32~1000000

None

The recommended value for this parameter is 31744 if PT is set to Transport MPGRP. Planning(Internal The recommended planning) value is 540000 if PT is set to ETH or ETHTRK.

LR

0~7

Default/Recommen MPGRP ded Value

0~1

Default/Recommen MPGRP ded Value

0~7

None

None

Transport Planning(Internal planning)

MPGRP

0~3

None

None

Transport Planning(Internal planning)

MPGRP

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen MPGRP ded Value

NONAUTH, PAP, CHAP

PAP(PAP Authentication)

PAP(PAP Authentication)

Default/Recommen MPGRP ded Value

1~67 characters

None

None

Transport Planning(Internal planning)

MPGRP

1~19 characters

None

None

Transport Planning(Internal planning)

MPGRP

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio MPGRP n with the peer)

Valid Mask address 0.0.0.0

None

Transport Planning(Negotiatio MPGRP n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio MPGRP n with the peer)

LONG, SHORT

LONG(Long)

LONG(Long)

Default/Recommen MPGRP ded Value

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen MPGRP ded Value

128~1500

256

256

Default/Recommen MPGRP ded Value

1~512

192

192

Default/Recommen MPGRP ded Value

3~1500

1500

1500

Default/Recommen MPGRP ded Value

1~1000

10

10

Default/Recommen MPGRP ded Value

4,8

None

Default/Recommen MPGRP ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen MPGRP ded Value

0~1000

100

100

Default/Recommen MPGRP ded Value

0~1000

50

50

Default/Recommen MPGRP ded Value

UP, DOWN

None

None

N/A

MPGRP

INITIAL, STARTING, CLOSED, STOPPED, CLOSING, STOPPING, REQSENT, ACKRCVD, ACKSENT, OPENED

None

None

N/A

MPGRP

INITIAL, STARTING, CLOSED, STOPPED, CLOSING, STOPPING, REQSENT, ACKRCVD, ACKSENT, OPENED

None

None

N/A

MPGRP

Valid IP address

None

None

N/A

MPGRP

Valid IP address

None

None

N/A

MPGRP

Valid IP address

None

None

N/A

MPGRP

DISABLE, ENABLE None

None

N/A

MPGRP

128~1500

None

None

N/A

MPGRP

DISABLE, ENABLE None

None

N/A

MPGRP

DISABLE, ENABLE None

None

N/A

MPGRP

DISABLE, ENABLE None

None

N/A

MPGRP

DISABLE, ENABLE None

None

N/A

MPGRP

0~4294967295

None

None

N/A

MPGRP

0~4294967295 0~4294967295 0~4294967295

None None None

None None None

N/A N/A N/A

MPGRP MPGRP MPGRP

0~4294967295

None

None

N/A

MPGRP

Valid IP address

None

None

N/A

MPGRP

BASE_BOARD, None E1_COVERBOARD

None

Transport Planning(Internal planning)

MPGRP

0~4294967295

None

None

N/A

MPGRP

0~4294967295

None

None

N/A

MPGRP

0~4294967295

None

None

N/A

MPGRP

0~4294967295

None

None

N/A

MPGRP

0~7

Default/Recommen MPLNK ded Value

0~1

Default/Recommen MPLNK ded Value

0~7

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

MPLNK

0~15

MPLNK

0~3

Default/Recommen MPLNK ded Value

0~1

Default/Recommen MPLNK ded Value

0~7

None

None

Transport Planning(Internal planning)

MPLNK

0~7

Default/Recommen MPLNK ded Value

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

Transport Planning(Internal planning)

MPLNK

128~1500

1500

1500

Default/Recommen MPLNK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen MPLNK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen MPLNK ded Value

1~65535

3000

3000

Default/Recommen MPLNK ded Value

BASE_BOARD, None E1_COVERBOARD

None

Transport Planning(Internal planning)

MPLNK

BASE_BOARD, None E1_COVERBOARD

If SBT is set to BASE_BOARD or BACK_BOARD, you are advised to set MPGRPSBT to BASE_BOARD. Default/Recommen If SBT is set to MPLNK ded Value E1_COVERBOARD , you are advised to set to MPGRPSBT to E1_COVERBOARD . None N/A MPLNK

UP, DOWN

None

INITIAL, STARTING, CLOSED, STOPPED, CLOSING, STOPPING, REQSENT, ACKRCVD, ACKSENT, OPENED

None

None

N/A

MPLNK

128~1500

None

None

N/A

MPLNK

DISABLE, ENABLE None

None

N/A

MPLNK

DISABLE, ENABLE None

None

N/A

MPLNK

BASE_BOARD, None E1_COVERBOARD

None

Transport Planning(Internal planning)

MPLNK

0~4294967295

None

None

N/A

MPLNK

0~4294967295

None

None

N/A

MPLNK

0~4294967295

None

None

N/A

MPLNK

0~4294967295

None

None

N/A

MPLNK

0~4294967295

None

None

N/A

MPLNK

0~4294967295

None

None

N/A

MPLNK

MASTER, SLAVE

None

None

Transport Planning(Internal planning)

OMCH

Valid IP address

None

None

Transport Planning(Negotiatio OMCH n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio OMCH n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio OMCH n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio OMCH n with the peer)

0~7

Default/Recommen OMCH ded Value

0~1

Default/Recommen OMCH ded Value

0~7

None

None

Transport Planning(Internal planning) Transport Planning(Internal planning)

OMCH

IPV4

IPV4(IPV4)

None

OMCH

NO, YES

NO(No)

NO(No)

Transport Planning(Internal planning)

OMCH

Valid IP address

None

None

Transport Planning(Negotiatio OMCH n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio OMCH n with the peer)

NEXTHOP, IF

NEXTHOP(Next Hop)

None

Transport Planning(Internal planning)

OMCH

PPP, MPGRP, TUNNEL

None

None

Transport Planning(Internal planning)

OMCH

0~14

None

None

Transport Planning(Internal planning)

OMCH

1~255

60

60

Transport Planning(Internal planning)

OMCH

Valid IP address

None

None

Transport Planning(Internal planning)

OMCH

NORMAL, ABNORMAL, UNKNOWN

None

None

N/A

OMCH

INUSE, UNUSED

None

None

N/A

OMCH

BASE_BOARD, BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

OMCH

Valid IP address

None

None

Transport Planning(Negotiatio OMCH6 n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio OMCH6 n with the peer)

NORMAL, ABNORMAL, UNKNOWN

None

None

N/A

OMCH6

0~7

Default/Recommen PACKETFILTER ded Value

0~1

Default/Recommen PACKETFILTER ded Value

0~7

None

None

Transport Planning(Internal planning)

PACKETFILTER

ETH, ETHTRK, TUNNEL

None

None

Transport Planning(Internal planning)

PACKETFILTER

0~14

None

None

Transport Planning(Internal planning)

PACKETFILTER

3000~3999

None

None

Transport Planning(Internal planning)

PACKETFILTER

PERMIT, DENY

PERMIT(Permit)

PERMIT(Permit)

Default/Recommen PACKETFILTER ded Value

BASE_BOARD, BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

0~4294967295

None

None

N/A

PACKETFILTER

4000~4999

None

None

Transport Planning(Internal planning)

PACKETFILTER

ADV_ACL, L2_ACL, ADV_AND_L2

ADV_ACL(Only Advanced ACL)

None

Transport Planning(Internal planning)

PACKETFILTER

Valid IP address

None

None

Transport Planning(Internal planning)

PINGFILTER

Valid Mask address None

None

Transport Planning(Internal planning)

PINGFILTER

PASSIVE, ACTIVE

PASSIVE(Passive Mode)

PASSIVE(Passive Mode)

Default/Recommen PMTUCFG ded Value

49152~65535

52889

52889

Default/Recommen PMTUCFG ded Value

500~5000

5000

5000

Default/Recommen PMTUCFG ded Value

5~60,65535

65535

65535

Default/Recommen PMTUCFG ded Value

0~63

63

63

Default/Recommen PMTUCFG ded Value

0~7

Default/Recommen PORTSECURITY ded Value

0~1

Default/Recommen PORTSECURITY ded Value

0~7

None

None

Transport Planning(Internal planning)

PORTSECURITY

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

PORTSECURITY

ETH, E1T1

Transport ETH(Ethernet Port) ETH(Ethernet Port) Planning(Internal planning)

PORTSECURITY

0~7

None

None

Transport Planning(Internal planning)

PORTSECURITY

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Transport Planning(Internal planning)

PORTSECURITY

0~7

Default/Recommen PPPLNK ded Value

0~1

Default/Recommen PPPLNK ded Value

0~7

None

None

Transport Planning(Internal planning)

PPPLNK

0~15

None

None

Transport Planning(Internal planning)

PPPLNK

0~7

None

None

Transport Planning(Internal planning)

PPPLNK

NONAUTH, PAP, CHAP

PAP(PAP Authentication)

PAP(PAP Authentication)

Default/Recommen PPPLNK ded Value

1~67 characters

None

None

Transport Planning(Internal planning)

PPPLNK

1~19 characters

None

None

Transport Planning(Internal planning)

PPPLNK

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, None TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

None

Transport Planning(Internal planning)

PPPLNK

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio PPPLNK n with the peer)

Valid Mask address 0.0.0.0

None

Transport Planning(Negotiatio PPPLNK n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio PPPLNK n with the peer)

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Default/Recommen PPPLNK ded Value

1~512

192

192

Default/Recommen PPPLNK ded Value

3~1500

1500

1500

Default/Recommen PPPLNK ded Value

1~1000

10

10

Default/Recommen PPPLNK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen PPPLNK ded Value

128~1500

1500

1500

Default/Recommen PPPLNK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen PPPLNK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen PPPLNK ded Value

1~65535

3000

3000

Default/Recommen PPPLNK ded Value

UP, DOWN

None

None

N/A

PPPLNK

INITIAL, STARTING, CLOSED, STOPPED, CLOSING, STOPPING, REQSENT, ACKRCVD, ACKSENT, OPENED

None

None

N/A

PPPLNK

INITIAL, STARTING, CLOSED, STOPPED, CLOSING, STOPPING, REQSENT, ACKRCVD, ACKSENT, OPENED

None

None

N/A

PPPLNK

INITIAL, STARTING, CLOSED, STOPPED, CLOSING, STOPPING, REQSENT, ACKRCVD, ACKSENT, OPENED

None

None

N/A

PPPLNK

Valid IP address

None

None

N/A

PPPLNK

Valid IP address

None

None

N/A

PPPLNK

Valid IP address

None

None

N/A

PPPLNK

DISABLE, ENABLE None

None

N/A

PPPLNK

DISABLE, ENABLE None

None

N/A

PPPLNK

DISABLE, ENABLE None

None

N/A

PPPLNK

128~1500

None

None

N/A

PPPLNK

DISABLE, ENABLE None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

Valid IP address

None

None

N/A

PPPLNK

1~1000

10

10

Default/Recommen PPPLNK ded Value

1~1000

Default/Recommen PPPLNK ded Value

BASE_BOARD, None E1_COVERBOARD

None

Transport Planning(Internal planning)

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~4294967295

None

None

N/A

PPPLNK

0~63

46

46

Default/Recommen PRI2QUE ded Value

0~63

34

34

Default/Recommen PRI2QUE ded Value

0~63

26

26

Default/Recommen PRI2QUE ded Value

0~63

18

18

Default/Recommen PRI2QUE ded Value

0~63

10

10

Default/Recommen PRI2QUE ded Value

0~63

Default/Recommen PRI2QUE ded Value

0~63

Default/Recommen PRI2QUE ded Value

0~7

Default/Recommen RSCGRP ded Value

0~1

Default/Recommen RSCGRP ded Value

0~7

None

None

Transport Planning(Internal planning)

RSCGRP

IP

None

None

Transport Planning(Internal planning)

RSCGRP

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

RSCGRP

PPP, MPGRP, ETH, ETHTRK, TUNNEL

None

None

Transport Planning(Internal planning)

RSCGRP

0~15

Transport Planning(Internal planning)

RSCGRP

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, None 14, 15, DEFAULTPORT

None

Transport Planning(Internal planning)

RSCGRP

KBPS

KBPS(Kbit/s)

None

Transport Planning(Internal planning)

RSCGRP

32~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

32~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

64~1000000

64

The recommended Transport value is twice the Planning(Internal TX bandwidth. planning)

RSCGRP

64~1000000

64

The recommended Transport value is twice the Planning(Internal TX bandwidth. planning)

RSCGRP

0~3

Transport Planning(Internal planning)

RSCGRP

1~100

100

100

Default/Recommen RSCGRP ded Value

64~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

64~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

64~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

64~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

64~1000000

None

None

Transport Planning(Internal planning)

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

SINGLE_RATE, DUAL_RATE

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

None

N/A

RSCGRP

0~4294967295

None

N/A

RSCGRP

0~7

Default/Recommen RSCGRPALG ded Value

0~1

Default/Recommen RSCGRPALG ded Value

0~7

None

None

Transport Planning(Internal planning)

RSCGRPALG

BASE_BOARD, E1_COVERBOARD , BACK_BOARD, None ETH_COVERBOAR D

None

Transport Planning(Internal planning)

RSCGRPALG

PPP, MPGRP, ETH, ETHTRK, TUNNEL

None

None

Transport Planning(Internal planning)

RSCGRPALG

0~15

Transport Planning(Internal planning)

RSCGRPALG

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, None 14, 15, DEFAULTPORT

None

Transport Planning(Internal planning)

RSCGRPALG

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design RSCGRPALG

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design RSCGRPALG

OFF, ON

OFF(Off)

OFF(Off)

Engineering Design RSCGRPALG

0~1000

30

30

Engineering Design RSCGRPALG

0~10000

50

50

Engineering Design RSCGRPALG

64~1000000

1024

1024

Engineering Design RSCGRPALG

64~1000000

1024

1024

Engineering Design RSCGRPALG

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Engineering Design RSCGRPALG

DISABLE, ENABLE DISABLE(Disable)

DISABLE(Disable)

Engineering Design RSCGRPALG

0~6

Engineering Design RSCGRPALG

0~500

50

50

Engineering Design RSCGRPALG

0~500

25

25

Engineering Design RSCGRPALG

0~1000000

Engineering Design RSCGRPALG

0~1000000

Engineering Design RSCGRPALG

0~8192

1000

1000

Engineering Design RSCGRPALG

0~79

None

None

Transport Planning(Internal planning)

SCTPLNK

0~7

Default/Recommen SCTPLNK ded Value Default/Recommen SCTPLNK ded Value Transport Planning(Internal planning) SCTPLNK

0~1

0~7

None

None

1~34

17

17

Default/Recommen SCTPLNK ded Value

Valid IP address

None

None

Transport Planning(Negotiatio SCTPLNK n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio SCTPLNK n with the peer)

1024~65535

None

None

Transport Planning(Negotiatio SCTPLNK n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio SCTPLNK n with the peer)

Valid IP address

0.0.0.0

None

Transport Planning(Negotiatio SCTPLNK n with the peer)

1024~65535

None

None

Transport Planning(Negotiatio SCTPLNK n with the peer)

10~59999

1000

1000

Default/Recommen SCTPLNK ded Value

11~60000

3000

3000

Default/Recommen SCTPLNK ded Value

10~59999

1000

1000

Default/Recommen SCTPLNK ded Value

1~99

12

12

Default/Recommen SCTPLNK ded Value

1~99

25

25

Default/Recommen SCTPLNK ded Value

1000~60000

5000

5000

Default/Recommen SCTPLNK ded Value

2~254

10

10

Default/Recommen SCTPLNK ded Value

1~253

Default/Recommen SCTPLNK ded Value

DISABLE, ENABLE DISABLE(Disable)

None

Default/Recommen SCTPLNK ded Value

DISABLE, ENABLE DISABLE(Disable)

None

Default/Recommen SCTPLNK ded Value

ALDER32, CRC32

CRC32(CRC32)

None

Default/Recommen SCTPLNK ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen SCTPLNK ded Value

1~254

10

10

Default/Recommen SCTPLNK ded Value

SCTP_STAT_DOW N, SCTP_STAT_CON None GESTION, SCTP_STAT_UP

None

N/A

SCTPLNK

SCTP_TRANSFER _CAUSE_START, SCTP_TRANSFER _CAUSE_LINKDO WN, SCTP_TRANSFER _CAUSE_PORTDI SABLED, SCTP_TRANSFER _CAUSE_INIT, None SCTP_TRANSFER _CAUSE_UNKNO WERROR, SCTP_TRANSFER _CAUSE_NORMAL , SCTP_TRANSFER _CAUSE_USERDE LETE

None

N/A

SCTPLNK

None

None

None

N/A

SCTPLNK

0~34

None

None

N/A

SCTPLNK

0~34

None

None

N/A

SCTPLNK

ACTIVE, STANDBY None

None

N/A

SCTPLNK

UNBLOCK, BLOCK

UNBLOCK(Unblock UNBLOCK(Unblock Default/Recommen SCTPLNK ) ) ded Value

10~500

200

200

Default/Recommen SCTPLNK ded Value

0~47 characters

NULL

None

Default/Recommen SCTPLNK ded Value

0~79

None

None

Transport Planning(Internal planning)

SCTPLNK6

1~34

17

17

Default/Recommen SCTPLNK6 ded Value

Valid IP address

None

None

Transport Planning(Negotiatio SCTPLNK6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio SCTPLNK6 n with the peer)

1024~65535

None

None

Transport Planning(Negotiatio SCTPLNK6 n with the peer)

Valid IP address

None

None

Transport Planning(Negotiatio SCTPLNK6 n with the peer)

Valid IP address

0:0:0:0:0:0:0:0

None

Transport Planning(Negotiatio SCTPLNK6 n with the peer)

1024~65535

None

None

Transport Planning(Negotiatio SCTPLNK6 n with the peer)

1000~60000

1000

1000

Default/Recommen SCTPLNK6 ded Value

1000~60000

3000

3000

Default/Recommen SCTPLNK6 ded Value

1000~60000

1000

1000

Default/Recommen SCTPLNK6 ded Value

1~99

12

12

Default/Recommen SCTPLNK6 ded Value

1~99

25

25

Default/Recommen SCTPLNK6 ded Value

1000~60000

5000

5000

Default/Recommen SCTPLNK6 ded Value

2~254

10

10

Default/Recommen SCTPLNK6 ded Value

1~253

Default/Recommen SCTPLNK6 ded Value

ALDER32, CRC32

CRC32(CRC32)

None

Default/Recommen SCTPLNK6 ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Default/Recommen SCTPLNK6 ded Value

1~254

10

10

Default/Recommen SCTPLNK6 ded Value

SCTP_STAT_DOW N, SCTP_STAT_CON None GESTION, SCTP_STAT_UP

None

N/A

SCTPLNK6

SCTP_TRANSFER _CAUSE_START, SCTP_TRANSFER _CAUSE_LINKDO WN, SCTP_TRANSFER _CAUSE_PORTDI SABLED, SCTP_TRANSFER _CAUSE_INIT, None SCTP_TRANSFER _CAUSE_UNKNO WERROR, SCTP_TRANSFER _CAUSE_NORMAL , SCTP_TRANSFER _CAUSE_USERDE LETE

None

N/A

SCTPLNK6

None

None

None

N/A

SCTPLNK6

0~34

None

None

N/A

SCTPLNK6

0~34

None

None

N/A

SCTPLNK6

ACTIVE, STANDBY None

None

N/A

SCTPLNK6

UNBLOCK, BLOCK

UNBLOCK(Unblock UNBLOCK(Unblock Default/Recommen SCTPLNK6 ) ) ded Value Transport Planning(Internal planning)

0~47 characters

NULL

None

SCTPLNK6

Valid IP address

None

None

Transport Planning(Internal planning)

SUBNETVLAN

Valid Mask address None

255.255.255.255

Transport Planning(Internal planning)

SUBNETVLAN

1~4094

None

None

Transport Planning(Internal planning)

SUBNETVLAN

OFF, ON

ON(On)

ON(On)

Default/Recommen TACALG ded Value

OFF, ON

ON(On)

ON(On)

Default/Recommen TACALG ded Value

0~100

100

100

Default/Recommen TACALG ded Value

0~100

100

100

Default/Recommen TACALG ded Value

0~100

100

100

Default/Recommen TACALG ded Value

0~100

100

100

Default/Recommen TACALG ded Value

0~100

Default/Recommen TACALG ded Value

0~100

Default/Recommen TACALG ded Value

0~100

Default/Recommen TACALG ded Value

0~100

Default/Recommen TACALG ded Value

0~100

Default/Recommen TACALG ded Value

0~100

90

90

Default/Recommen TACALG ded Value

0~100

90

90

Default/Recommen TACALG ded Value

0~100

85

85

Default/Recommen TACALG ded Value

0~100

85

85

Default/Recommen TACALG ded Value

0~100

85

85

Default/Recommen TACALG ded Value

0~100

85

85

Default/Recommen TACALG ded Value

0~100

85

85

Default/Recommen TACALG ded Value

0~100

85

85

Default/Recommen TACALG ded Value

0~100

100

100

Default/Recommen TACALG ded Value

0~100

100

100

Default/Recommen TACALG ded Value

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen TACALG ded Value

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen TACALG ded Value

OFF, ON

ON(On)

ON(On)

Default/Recommen TACALG ded Value

OFF, ON

ON(On)

ON(On)

Default/Recommen TACALG ded Value

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen TACALG ded Value

OFF, ON

OFF(Off)

OFF(Off)

Default/Recommen TACALG ded Value

0~100

70

70

Default/Recommen TLDRALG ded Value

0~100

70

70

Default/Recommen TLDRALG ded Value

0~100

65

65

Default/Recommen TLDRALG ded Value

0~100

65

65

Default/Recommen TLDRALG ded Value

0~100

50

50

Default/Recommen TLDRALG ded Value

0~100

50

50

Default/Recommen TLDRALG ded Value

0~100

45

45

Default/Recommen TLDRALG ded Value

0~100

45

45

Default/Recommen TLDRALG ded Value

DISABLE, ENABLE ENABLE(Enable)

ENABLE(Enable)

Transport Planning(Internal planning)

TLFRSWITCH

OFF, ON

ON(On)

ON(On)

Default/Recommen TOLCALG ded Value

OFF, ON

ON(On)

ON(On)

Default/Recommen TOLCALG ded Value

0~100

95

95

Default/Recommen TOLCALG ded Value

0~100

90

90

Default/Recommen TOLCALG ded Value

0~100

Default/Recommen TOLCALG ded Value

0~100

95

95

Default/Recommen TOLCALG ded Value

0~100

90

90

Default/Recommen TOLCALG ded Value

WHITELIST, BLACKLIST

Transport WHITELIST(Whiteli WHITELIST(Whiteli Planning(Internal st) st) planning)

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~4294967295

None

None

N/A

TRANSPORT

0~7

None

Transport Planning(Internal planning)

TUNNEL

0~1

None

Transport Planning(Internal planning)

TUNNEL

0~7

None

None

Transport Planning(Internal planning)

TUNNEL

0~14

None

None

Transport Planning(Internal planning)

TUNNEL

0~7

None

None

Transport Planning(Internal planning)

TUNNEL

0~1

None

None

Transport Planning(Internal planning)

TUNNEL

0~7

None

None

Transport Planning(Internal planning)

TUNNEL

0~4294967295

None

None

N/A

TUNNEL

0~4294967295

None

None

N/A

TUNNEL

0~4294967295

None

None

N/A

TUNNEL

0~4294967295

None

None

N/A

TUNNEL

0~3

None

None

Transport Planning(Internal planning)

VLANCLASS

USERDATA, SIG, OTHER, OM_HIGH, OM_LOW

None

None

Transport Planning(Internal planning)

VLANCLASS

0~63

It is recommended that the value of this parameter be Transport consistent with the Planning(Internal implementation of planning) the differentiated service. Transport Planning(Internal planning)

VLANCLASS

1~4094

None

None

VLANCLASS

0~7

Transport Planning(Internal planning)

VLANCLASS

Valid IP address

None

None

Transport Planning(Internal planning)

VLANMAP

Valid Mask address 255.255.255.255

None

Transport Planning(Internal planning)

VLANMAP

SINGLEVLAN, VLANGROUP

None

None

Transport Planning(Internal planning)

VLANMAP

1~4094

None

None

Transport Planning(Internal planning)

VLANMAP

0~7

Transport Planning(Internal planning)

VLANMAP

0~3

None

None

Transport Planning(Internal planning)

VLANMAP

DISABLE, ENABLE ENABLE(Enable)

DISABLE(Disable)

Transport Planning(Internal planning)

VLANMAP

5000~60000

5000

5000

Default/Recommen GTPU ded Value

3~6

Default/Recommen GTPU ded Value

0~63

63

63

Default/Recommen GTPU ded Value

DISABLE, ENABLE DISABLE(Disable)

None

Default/Recommen GTPU ded Value

Parameter Relationship

Access

Service Interrupted After Modification

Interruption Scope

Interruption Duration (min)

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

The parameter is used only when the PROTOCOL Read & Write parameter is set to TDL_IR. None Read Only

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If some cells of an eNodeB are neighboring cells of each other, the neighbor relationships with these cells must be removed manually Read & Write before the configuration of the eNodeB is modified. The eNodeB must be reset after the modification so that the parameter can take effect.

Yes

eNodeB

<3

The value of NAME is a string of characters. The string cannot be null characters or contain any of the following characters: question marks (?), colons (:), right angle brackets (>), left angle brackets (<), stars (*), slashes (/), Read & Write backslashes (\), pipes (|), double quotation marks ("), commas (,), semicolons (;), equal signs (=), single quotation marks ('), three plus signs (+++), two or more continuous blanks, and two or more continuous percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

eNodeB

<3

None

Read & Write

Yes

eNodeB

When the automatic power control switch is turned on, the services of a cell are interrupted from the automatic poweroff time to the next automatic power-on time.

1. PowerOffTime must range from 22:00:00 to 05:00:00 of the next day. Read & Write 2. PowerOnTime must be an hour later than PowerOffTime. 1. PowerOnTime must be an hour later than PowerOffTime. Read & Write 2. PowerOnTime must range from 23:00:00 to 06:00:00 of the next day.

Yes

eNodeB

When the automatic power control switch is turned on, the services of a cell are interrupted from the automatic poweroff time to the next automatic power-on time.

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when GCDF is set to DEG.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when GCDF is set to DEG.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

LONGITUDE and LATITUDE are valid only when this parameter is set to DEG. LONGITUDESECF Read & Write ORMAT and LONGITUDESECF ORMAT are valid only when this parameter is set to SEC. 1. This parameter must be specified if GCDF is set to SEC. 2. If GCDF is set to SEC, this parameter must be specified in the format of dd:mm:ss.ssss. dd indicates the degree ranging from -90 to Read & Write +90, mm indicates the minute ranging from 0 to 59, and ss.ssss indicates the second ranging from 0 to 59.9999. The value range of this parameter is from -90:00:00.0000 to +90:00:00.0000.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

1. This parameter must be specified if GCDF is set to SEC. 2. If GCDF is set to SEC, this parameter must be specified in the format of ddd:mm:ss.ssss. ddd indicates the degree ranging from Read & Write -180 to +180, mm indicates the minute ranging from 0 to 59, and ss.ssss indicates the second ranging from 0 to 59.9999. The value range of this parameter is from 180:00:00.0000 to +180:00:00.0000.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

eNodeB

<3

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

1. The value range of FLTTHRESHOLD depends on the value of KPITYPE. If KPITYPE is set to Transmission_Pack et_Loss_Rate, the threshold is set to a value in the range of 0 to 1000. If KPITYPE is set to Transmission_Dela y, the threshold is set to a value in the range of 0 ms to 5000 ms. Read & Write If KPITYPE is set to Transmission_Jitter, the threshold is set to a value in the range of 0 ms to 1000 ms. If KPITYPE is set to Packet_Loss_Rate, the threshold is set to a value in the range of 0 to 1000. If KPITYPE is set to Cell_RRC_Connect _Succ_Rate, the threshold is set to a value in the range

No (And no impact on the UE in idle mode)

N/A

N/A

1. FLTTHRESHOLD must be greater than RESTHRESHOLD if KPITYPE is set to Transmission_Pack et_Loss_Rate, Transmission_Dela y, Transmission_Jitter, Packet_Loss_Rate, or Cell_Call_Drop_Rat e. 2. FLTTHRESHOLD Read & Write must be less than RESTHRESHOLD if KPITYPE is set to Cell_RRC_Connect _Succ_Rate, Cell_ERAB_Setup_ Succ_Rate, IntraFrequency_HO_Su cc_Rate, InterFrequency_HO_Su cc_Rate, LTECDMA_Handover_ Succ_Rate, LTEWCDMA_Handover _Succ_Rate, or LTEGERAN_Handover _Succ_Rate.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cells

None

Read & Write

Yes

Cells

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read & Write

Yes

Cells

<1

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When CTRLCN in the ALD MO is set to 0, the value range of CTRLSRN is 4 to 5, or 60 to Read & Write 254. When the value range of CTRLCN in the ALD MO is 1 to 62, CTRLSRN is set to 4 or 5.

No (And no impact on the UE in idle mode)

N/A

N/A

When CTRLSRN in the ALD MO is set to 4 or 5, the value of CTRLSN ranges from 0 to 8 if TYPE in the Cabinet MO where the ALD MO is located is set to BTS3900AL. The Read & Write value of CTRLSN ranges from 0 to 5 if TYPE is not set to BTS3900AL. When the value of CTRLSRN in the ALD MO ranges from 60 to 254, CTRLSN is set to 0.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the RET MO, when SCENARIO is not set to REGULAR, Read & Write VENDORCODE and SERIALNO must be specified. In the RET MO, when SCENARIO is not set to REGULAR, Read & Write VENDORCODE and SERIALNO must be specified. None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When CN in the AntennaPort MO is set to 0, the value range of SRN is 4 to 5 or 60 to 254. When the value of Read Only CN in the AntennaPort MO ranges from 1 to 62, the value of SRN is set to 4 or 5. When SRN in the AntennaPort MO is set to 4 or 5, the value of SN ranges from 0 to 8 if TYPE of the Cabinet MO where the AntennaPort MO is located is set to Read Only BTS3900AL. The value of CTRLSN ranges from 0 to 5 if TYPE is not set to BTS3900AL. When the value of SRN in the AntennaPort MO ranges from 60 to 254, SN is set 0.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the same RRU MO, PWRSWITCH in the RetPort MO and PWRSWITCH Read & Write in the AntennaPort cannot be set to ON at the same time.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an AntennaPort MO, if PWRSWITCH is set to ON, the value of Read & Write UOTHD must be smaller than UCTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

In an AntennaPort MO, if PWRSWITCH is set to ON, the value of UOTHD must be smaller than UCTHD. Read & Write In an AntennaPort MO, if PWRSWITCH is set to ON, the value of UCTHD must be smaller than OCTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

In an AntennaPort MO, if PWRSWITCH is set to ON, the value of Read & Write OCTHD must be smaller than OOTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

In an AntennaPort MO, if PWRSWITCH is set to ON, the value of OCTHD must be smaller than OOTHD. Read & Write In an AntennaPort MO, if PWRSWITCH is set to ON, the value of UCTHD must be smaller than OCTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When POLARTYPE and RETTYPE in a RET are set to SINGLE and SINGLE_RET, respectively, only Read & Write one of CONNCN1 and CONNCN2 in the RETSubunit MO needs to be configured. The SCENARIO should be configured on the basis of actual physical connection and meet the following conditions: 1. When SCENARIO is set to REGULAR, one Read & Write RRU can control one RET; 2. When SCENARIO is set to DAISY_CHAIN or SECTOR_SPLITTI NG or 2G_EXTENSION, one RRU can control more than one RET.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) N/A

N/A

N/A

None

Read Only

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When CTRLCN in the ALD MO is set to 0, the value range of CTRLSRN is 4 to 5, or 60 to Read & Write 254. When the value range of CTRLCN in the ALD MO is 1 to 62, CTRLSRN is set to 4 or 5.

No (And no impact on the UE in idle mode)

N/A

N/A

When CTRLSRN in the ALD MO is set to 4 or 5, the value of CTRLSN ranges from 0 to 8 if TYPE in the Cabinet MO where the ALD MO is located is set to BTS3900AL. The Read & Write value of CTRLSN ranges from 0 to 5 if TYPE is not set to BTS3900AL. When the value of CTRLSRN in the ALD MO ranges from 60 to 254, CTRLSN is set to 0.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the RET MO, when SCENARIO is not set to REGULAR, Read & Write VENDORCODE and SERIALNO must be specified. In the RET MO, when SCENARIO is not set to REGULAR, Read & Write VENDORCODE and SERIALNO must be specified. None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetDeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to UNUSED. When BAND3 is not set to Read & Write UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to UNUSED, BAND3 must be greater than BAND2. When

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetDeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to UNUSED. When BAND3 is not set to Read & Write UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to UNUSED, BAND3 must be greater than BAND2. When

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetDeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to UNUSED. When BAND3 is not set to Read & Write UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to UNUSED, BAND3 must be greater than BAND2. When

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetDeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to UNUSED. When BAND3 is not set to Read & Write UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a RetDeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to UNUSED, BAND3 must be greater than BAND2. When

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None None None

Read Only Read Only Read Only Read Only

N/A N/A N/A N/A

N/A N/A N/A N/A

N/A N/A N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the same RRU MO, PWRSWITCH in the RetPort MO and PWRSWITCH Read & Write in the AntennaPort cannot be set to ON at the same time.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetPort MO, if PWRSWITCH is set to ON, the value of Read & Write UOTHD must be smaller than UCTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetPort MO, if PWRSWITCH is set to ON, the value of UOTHD must be smaller than UCTHD. Read & Write In a RetPort MO, if PWRSWITCH is set to ON, the value of UCTHD must be smaller than OCTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetPort MO, if PWRSWITCH is set to ON, the value of Read & Write OCTHD must be smaller than the value of OOTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

In a RetPort MO, if PWRSWITCH is set to ON, the value of OCTHD must be smaller than the value of OOTHD. Read & Write In a RetPort MO, if PWRSWITCH is set to ON, the value of UCTHD must be smaller than OCTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

Only one RETSubunit MO can be configured on an AntennaPort MO. When CONNCN1 in a RETSubunit MO is set to a value other than 255, CONNSRN1 and CONNSN1 must all be set to a value other than 255. Similarly, when CONNCN2 in a RETSubunit MO is set to a value other Read & Write than 255, CONNSRN2 and CONNSN2 must all be set to a value other than 255. In a RETSubunit MO, the combination of CONNCN1, CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and

No (And no impact on the UE in idle mode)

N/A

N/A

Only one RETSubunit MO can be configured on an AntennaPort MO. When CONNCN1 in a RETSubunit MO is set to a value other than 255, CONNSRN1 and CONNSN1 must all be set to a value other than 255. Similarly, when CONNCN2 in a RETSubunit MO is set to a value other Read & Write than 255, CONNSRN2 and CONNSN2 must all be set to a value other than 255. In a RETSubunit MO, the combination of CONNCN1, CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and

No (And no impact on the UE in idle mode)

N/A

N/A

Only one RETSubunit MO can be configured on an AntennaPort MO. When CONNCN1 in a RETSubunit MO is set to a value other than 255, CONNSRN1 and CONNSN1 must all be set to a value other than 255. Similarly, when CONNCN2 in a RETSubunit MO is set to a value other Read & Write than 255, CONNSRN2 and CONNSN2 must all be set to a value other than 255. In a RETSubunit MO, the combination of CONNCN1, CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and Only one RETSubunit MO can be configured on an AntennaPort MO. In a RETSubunit MO, the combination of CONNCN1, Read & Write CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and CONNPN2.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

Only one RETSubunit MO can be configured on an AntennaPort MO. When CONNCN1 in a RETSubunit MO is set to a value other than 255, CONNSRN1 and CONNSN1 must all be set to a value other than 255. Similarly, when CONNCN2 in a RETSubunit MO is set to a value other Read & Write than 255, CONNSRN2 and CONNSN2 must all be set to a value other than 255. In a RETSubunit MO, the combination of CONNCN1, CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and

No (And no impact on the UE in idle mode)

N/A

N/A

Only one RETSubunit MO can be configured on an AntennaPort MO. When CONNCN1 in a RETSubunit MO is set to a value other than 255, CONNSRN1 and CONNSN1 must all be set to a value other than 255. Similarly, when CONNCN2 in a RETSubunit MO is set to a value other Read & Write than 255, CONNSRN2 and CONNSN2 must all be set to a value other than 255. In a RETSubunit MO, the combination of CONNCN1, CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and

No (And no impact on the UE in idle mode)

N/A

N/A

Only one RETSubunit MO can be configured on an AntennaPort MO. When CONNCN1 in a RETSubunit MO is set to a value other than 255, CONNSRN1 and CONNSN1 must all be set to a value other than 255. Similarly, when CONNCN2 in a RETSubunit MO is set to a value other Read & Write than 255, CONNSRN2 and CONNSN2 must all be set to a value other than 255. In a RETSubunit MO, the combination of CONNCN1, CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and Only one RETSubunit MO can be configured on an AntennaPort MO. In a RETSubunit MO, the combination of CONNCN1, Read & Write CONNSRN1, CONNSN1, and CONNPN1 cannot be the same as the combination of CONNCN2, CONNSRN2, CONNSN2, and CONNPN2.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

The value of SUBNAME must be Read & Write unique in RETSubunit MOs. None Read & Write

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When CTRLCN in the ALD MO is set to 0, the value range of CTRLSRN is 4 to 5, or 60 to Read & Write 254. When the value range of CTRLCN in the ALD MO is 1 to 62, CTRLSRN is set to 4 or 5.

No (And no impact on the UE in idle mode)

N/A

N/A

When CTRLSRN in the ALD MO is set to 4 or 5, the value of CTRLSN ranges from 0 to 8 if TYPE in the Cabinet MO where the ALD MO is located is set to BTS3900AL. The Read & Write value of CTRLSN ranges from 0 to 5 if TYPE is not set to BTS3900AL. When the value of CTRLSRN in the ALD MO ranges from 60 to 254, CTRLSN is set to 0.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the RET MO, when SCENARIO is not set to REGULAR, Read & Write VENDORCODE and SERIALNO must be specified. In the RET MO, when SCENARIO is not set to REGULAR, Read & Write VENDORCODE and SERIALNO must be specified. None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a TMADeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to Read & Write UNUSED. When BAND3 is not set to UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to

No (And no impact on the UE in idle mode)

N/A

N/A

In a TMADeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to Read & Write UNUSED. When BAND3 is not set to UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to

No (And no impact on the UE in idle mode)

N/A

N/A

In a TMADeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to Read & Write UNUSED. When BAND3 is not set to UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to

No (And no impact on the UE in idle mode)

N/A

N/A

In a TMADeviceData MO, if BAND1 is not set to UNUSED, BAND1 cannot be the same as BAND2, BAND3, or BAND4. The same rule applies to BAND2, BAND3, and BAND4. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND3 cannot be set to Read & Write UNUSED. When BAND3 is not set to UNUSED, BAND2 cannot be set to UNUSED. When BAND2 is not set to UNUSED, BAND1 cannot be set to UNUSED. In a TMADeviceData MO, when BAND4 is not set to UNUSED, BAND4 must be greater than BAND3. When BAND3 is not set to

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The four frequency bands supported by Read Only the TMA must differ from each other.

N/A

N/A

N/A

The four frequency bands supported by Read Only the TMA must differ from each other.

N/A

N/A

N/A

The four frequency bands supported by Read Only the TMA must differ from each other.

N/A

N/A

N/A

The four frequency bands supported by Read Only the TMA must differ from each other.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

If RXMINFB or RXMAXFB in the TMADeviceData Read Only MO is set, RXMINFB must be smaller than RXMAXFB. If TXMINFB or TXMAXFB in the TMADeviceData MO is set, TXMINFB must be smaller than TXMAXFB. If TXMINFB or TXMAXFB in the TMADeviceData MO is set, TXMINFB must be smaller than TXMAXFB.

N/A

N/A

N/A

Read Only

N/A

N/A

N/A

Read Only

N/A

N/A

N/A

If RXMINFB or RXMAXFB in the TMADeviceData Read Only MO is set, RXMINFB must be smaller than RXMAXFB. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a TMASubunit MO, a unique combination of CONNCN, CONNSRN, CONNSN, and CONNPN is necessary. In a TMASubunit MO, a unique combination of CONNCN, CONNSRN, CONNSN, and CONNPN is necessary. In a TMASubunit MO, a unique combination of CONNCN, CONNSRN, CONNSN, and CONNPN is necessary. In a TMASubunit MO, a unique combination of CONNCN, CONNSRN, CONNSN, and CONNPN is necessary.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The following parameters cannot be set to the same value: DEVICENAME in the RET MO, DEVICENAME in the TMA MO,and DEVICENAME in the VRET MO.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

If CONNPN1,CONNP N2,CONNPN3 and CONNPN4 in a VRETSubunit MO are not set to NULL, Read & Write they must be different. Only one VRETSubunit MO can be connected to a VAntennaPort MO.

No (And no impact on the UE in idle mode)

N/A

N/A

If CONNPN1,CONNP N2,CONNPN3 and CONNPN4 in a VRETSubunit MO are not set to NULL, Read & Write they must be different. Only one VRETSubunit MO can be connected to a VAntennaPort MO.

No (And no impact on the UE in idle mode)

N/A

N/A

The value of SUBNAME must be unique in Read & Write VRETSubunit MOs.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If CONNPN1,CONNP N2,CONNPN3 and CONNPN4 in a VRETSubunit MO are not set to NULL, Read & Write they must be different. Only one VRETSubunit MO can be connected to a VAntennaPort MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If CONNPN1,CONNP N2,CONNPN3 and CONNPN4 in a VRETSubunit MO are not set to NULL, Read & Write they must be different. Only one VRETSubunit MO can be connected to a VAntennaPort MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If MODE and CLKSRC in the Tasm MO are set to MANUAL and TOD, respectively, TYPE of the corresponding TOD Read Only MO must be set to IN. In a TOD MO, when SN is set to 6 or 7, TYPE cannot be set to OUT.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When two TOD MOs have the value 6 or 7 for SN, SN in one TOD MO must be set to 6 and SN in the other TOD MO must be set to 7. When SN in two TOD MOs both are greater than or equal to 0 and smaller than or Read Only equal to 5, the values of SN in the two MOs must be the same. The values of SN in two TOD MOs must both be greater than or equal to 0 and smaller than or equal to 5, or greater than or equal to 6 and smaller than or equal to 7.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When a GPS MO is configured on a BBU subrack, GN Read Only must be set to 0 or 1.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

When ICPT in the IPCLKLNK MO is set to HW_DEFINED, PT in a DEVIP MO corresponding to the IPCLKLNK MO cannot be set to LOOPINT. If two IPCLKLNK MOs have been configured, the two MOs must have the same ICPT value. When two IPCLKLNK MOs are configured, the Read Only values of MACMODE are both set to YES and the values of CLKMAC must be different in the two MOs when the following conditions are met: 1. The values of ICPT are both set to PTP; 2. The values of CNM are both set to L2_MULTICAST. When two IPCLKLNK MOs are configured, the

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the IPCLKLNK MO, CIP is valid only when CNM is not set to L2_MULTICAST and IPMODE is set to IPV4. When two IPCLKLNK MOs are configured, the values of CIP in the two MOs must be the same when the following conditions are met: 1. ICPT is set to PTP and CNM is not set to Read Only L2_MULTICAST in the two MOs; 2. IPMODE is set to IPV4 in the two MOs. In the IPCLKLNK MO, if CNM is not set to L2_MULTICAST and IPMODE is set to IPV4, CIP cannot be set to 0.0.0.0, 255.255.255.255, 127.x.x.x, or 0.x.x.x, and should be one of CLASS A, CLASS B, CLASS

N/A

N/A

N/A

In the IPCLKLNK MO, SIP is valid only when CNM is not set to L2_MULTICAST and IPMODE is set to IPV4. In an IPCLKLNK MO, SIP cannot be set to 0.0.0.0, 255.255.255.255, 127.x.x.x, or 0.x.x.x, and should be one of CLASS A, CLASS B, CLASS C, when the following conditions Read Only are met: 1. CNM is not set to L2_MULTICAST; 2. IPMODE is set to IPV4. When two IPCLKLNK MOs are configured on the same board, the values of SIP in the two MOs must be different when the following conditions are met: 1. ICPT is set to PTP and CNM is not set to L2_MULTICAST

N/A

N/A

N/A

The DM is valid only when ICPT in the Read Only IPCLKLNK MO is set to PTP.

N/A

N/A

N/A

When ICPT in the IPCLKLNK MO is set to HW_DEFINED, CMPST and DELAYTYPE in the IPCLKLNK MO Read & Write cannot be configured. The DELAYTYPE is valid only when ICPT in the IPCLKLNK MO is set to PTP.

No (And no impact on the UE in idle mode)

N/A

N/A

When CLASSIDENTIFY in the IPCLKLNK MO is set to OFF, the BMC algorithm is disabled, and the settings of CLASS0, CLASS1, CLASS2, and CLASS3 do not take effect. When CLASSIDENTIFY in the IPCLKLNK MO Read & Write is set to ON, the BMC algorithm is enabled. If there are multiple clock servers at different clock quality levels, the server that meets the customer's requirements to the most extent is selected in descending order of priority.

No (And no impact on the UE in idle mode)

N/A

N/A

When CLASSIDENTIFY in the IPCLKLNK MO is set to OFF, the BMC algorithm is disabled, and the setting of CLASS0 does not take effect. When CLASSIDENTIFY in the IPCLKLNK MO is set to ON, the BMC algorithm is enabled. If there are multiple clock servers at different Read & Write clock quality levels, the server that meets the customer's requirements to the most extent is selected in descending order of priority. The values of any two parameters among CLASS0, CLASS1, CLASS2, and CLASS3 in an IPCLKLNK must be different.

No (And no impact on the UE in idle mode)

N/A

N/A

When CLASSIDENTIFY in the IPCLKLNK MO is set to OFF, the BMC algorithm is disabled, and the setting of CLASS1 does not take effect. When CLASSIDENTIFY in the IPCLKLNK MO is set to ON, the BMC algorithm is enabled. If there are multiple clock servers at different Read & Write clock quality levels, the server that meets the customer's requirements to the most extent is selected in descending order of priority. The values of any two parameters among CLASS0, CLASS1, CLASS2, and CLASS3 in an IPCLKLNK must be different.

No (And no impact on the UE in idle mode)

N/A

N/A

When CLASSIDENTIFY in the IPCLKLNK MO is set to OFF, the BMC algorithm is disabled, and the setting of CLASS2 does not take effect. When CLASSIDENTIFY in the IPCLKLNK MO is set to ON, the BMC algorithm is enabled. If there are multiple clock servers at different Read & Write clock quality levels, the server that meets the customer's requirements to the most extent is selected in descending order of priority. The values of any two parameters among CLASS0, CLASS1, CLASS2, and CLASS3 in an IPCLKLNK must be different.

No (And no impact on the UE in idle mode)

N/A

N/A

When CLASSIDENTIFY in the IPCLKLNK MO is set to OFF, the BMC algorithm is disabled, and the setting of CLASS3 does not take effect. When CLASSIDENTIFY in the IPCLKLNK MO is set to ON, the BMC algorithm is enabled. If there are multiple clock servers at different Read & Write clock quality levels, the server that meets the customer's requirements to the most extent is selected in descending order of priority. The values of any two parameters among CLASS0, CLASS1, CLASS2, and CLASS3 in an IPCLKLNK must be different.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the IPCLKLNK MO, the MACMODE is valid only when ICPT is Read & Write set to PTP and CNM is set to L2_MULTICAST. In the IPCLKLNK MO, the CLKMAC is valid only when ICPT is set to PTP, Read & Write CNM is set to L2_MULTICAST, and MACMODE is set to YES.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The CNM is valid only when ICPT in Read Only the IPCLKLNK MO is set to PTP. When ICPT in the IPCLKLNK MO is set to HW_DEFINED, CMPST and DELAYTYPE in the Read & Write IPCLKLNK MO cannot be configured. The CMPST is valid only when ICPT in the IPCLKLNK MO is set to PTP.

N/A

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When two IPCLKLNK MOs are configured, the values of PRI must Read & Write be the same if the values of ICPT are both set to PTP in the two MOs.

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPCLKLNK MO, ANNFREQ is valid only when CNM is set to UNICAST and PROFILETYPE is set to G.8265.1.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPCLKLNK MO, SYNCFREQ is valid only when Read & Write CNM is set to UNICAST and PROFILETYPE is set to G.8265.1.

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPCLKLNK MO, MASTERPRIO is valid only when Read & Write CNM is set to UNICAST and PROFILETYPE is set to G.8265.1.

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPCLKLNK MO, PROFILETYPE is valid only when CNM is set to UNICAST. If PROFILETYPE in the IPCLKLNK MO is set to G.8265.1, CLKSYNCMODE in the Tasm MO must be set to FREQ. When two IPCLKLNK MOs are configured, the values of NEGDURATION in Read & Write the two MOs must be the same when the following conditions are met: 1. The values of ICPT are both set to PTP; 2. The values of CNM are both set to UNICAST; 3. The values of PROFILETYPE are both set to G.8265.1. When two IPCLKLNK MOs are configured, the values of

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPCLKLNK MO, NEGDURATION is valid only when CNM is set to UNICAST and PROFILETYPE is set to G.8265.1. When two IPCLKLNK MOs are configured, the values of NEGDURATION in the two MOs must be the same when the following conditions are met: Read & Write 1. The values of ICPT are both set to PTP; 2. The values of CNM are both set to UNICAST; 3. The values of PROFILETYPE are both set to G.8265.1. When two IPCLKLNK MOs are configured, the values of PROFILETYPE in the two MOs must be the same when the following If two IPCLKLNK MOs are configured, the two MOs must have the same IPMODE value. Read Only If IPMODE in the IPCLKLNK MO is set to IPV6, CLKSYNCMODE in the Tasm MO must be set to FREQ.

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

In the IPCLKLNK MO, CIPV6 is valid only when CNM is not set to L2_MULTICAST and IPMODE is set to IPV6. In the IPCLKLNK MO, SIPV6 and CIPV6 must be set to different values when ICPT is set to PTP and CNM is not set to L2_MULTICAST and IPMODE is set Read Only to IPV6. When two IPCLKLNK MOs are configured, the values of CIPV6 in the two MOs must be the same when the following conditions are met: 1. ICPT is set to PTP and CNM is not set to L2_MULTICAST in the two MOs; 2. IPMODE is set to IPV6 in the two MOs.

N/A

N/A

N/A

In the IPCLKLNK MO, SIPV6 is valid only when CNM is not set to L2_MULTICAST and IPMODE is set to IPV6. When two IPCLKLNK MOs are configured on the same board, the values of SIPV6 in Read Only the two MOs must be different when the following conditions are met: 1. ICPT is set to PTP and CNM is not set to L2_MULTICAST; 2. IPMODE is set to IPV6 in the two MOs.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When a MPT MO is configured in the slot corresponding Read Only to the SN in the SyncEth MO, PN is set to 0 or 1.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The SRCNO is valid only when the clock source specified by the CLKSRC in the Tasm MO supports Read & Write more than one clock link and the value of MODE is set to MANUAL.

No (And no impact on the UE in idle mode)

N/A

N/A

The CLKSRC is valid only when MODE in the Tasm MO is set to MANUAL. If MODE and CLKSRC in the Read & Write Tasm MO are set to MANUAL and TOD, respectively, TYPE of the corresponding TOD MO must be set to IN.

No (And no impact on the UE in idle mode)

N/A

N/A

When MODE is set to MANUAL and CLKSRC is set to SYNCETH+IPCLK or GPS+SYNCETH, the value of MODE can be changed to AUTO only in the following methods: 1. Change the value of MODE from MANUAL to FREE, and then to AUTO; 2. Change the value Read & Write of CLKSRC to other values, and then change the value of MODE to AUTO. If MODE and CLKSRC in the Tasm MO are set to MANUAL and TOD, respectively, TYPE of the corresponding TOD MO must be set to IN.

No (And no impact on the UE in idle mode)

N/A

N/A

If PROFILETYPE in the IPCLKLNK MO is set to G.8265.1, CLKSYNCMODE in the Tasm MO must be set to FREQ. Read & Write If IPMODE in the IPCLKLNK MO is set to IPV6, CLKSYNCMODE in the Tasm MO must be set to FREQ.

Yes

Cells

Services of the cells recover after the reference clock is locked again.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

BS

Services are interrupted until the reference clock is qualified.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When AT in the RRUCHAIN MO is set to PEERPORT, the board specified by HSN must have not been configured. When AT in the RRUCHAIN MO is set to PEERPORT, Read Only if HSN equal to 2, the BBP with the value of SN equal to 3 must have been configured; if HSN equal to 3, the BBP with the value of SN equal to 2 must have been configured. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, WM in the BBP MO corresponding to HCN, HSRN, and Read & Write HSN must be the same as the WM in the BBP MO corresponding to TCN, TSRN, and TSN.

Yes

The services carried on the baseband processing board and the services Less than 1 minute carried on RF modules connected to the baseband processing board

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

The operated board Less than 2 minutes

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

MPN in the CCU MOs under the Read & Write same manager unit must be the same.

N/A

N/A

None

Read & Write

N/A

N/A

CCN in the CCU MOs under the Read & Write same manager unit must be unique. In the CCU MO, CS is valid only when Read & Write DCF is set to YES.

N/A

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None None

Read Only Read Only Read Only

N/A N/A N/A

N/A N/A N/A

N/A N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

CN, SRN and SN in the CpriPort must meet the following conditions: 1. when CN is set to 0, SRN must be set to 0~1, 4~5 or 60~254; 2. when CN is set to 1~7, SRN must be set to 0~1, 4~5; 3. when CN is set to 8~62, SRN must be set to 4~5; 4. when SRN is set to 0~1, SN must be set to Read Only 0~7; 5. when SRN is set to 4~5 and TYPE in the Cabinet is equal to BTS3900AL, SN must be set to 0~8; 6. when SRN is set to 4~5 and TYPE in the Cabinet is not equal to BTS3900AL, SN must be set to 0~5; 7. when SRN is set to 60~254, SN must be set to 0.

N/A

N/A

N/A

CN, SRN and SN in the CpriPort must meet the following conditions: 1. when CN is set to 0, SRN must be set to 0~1, 4~5 or 60~254; 2. when CN is set to 1~7, SRN must be set to 0~1, 4~5; 3. when CN is set to 8~62, SRN must be set to 4~5; 4. when SRN is set to 0~1, SN must be set to Read Only 0~7; 5. when SRN is set to 4~5 and TYPE in the Cabinet is equal to BTS3900AL, SN must be set to 0~8; 6. when SRN is set to 4~5 and TYPE in the Cabinet is not equal to BTS3900AL, SN must be set to 0~5; 7. when SRN is set to 60~254, SN must be set to 0.

N/A

N/A

N/A

CN, SRN and SN in the CpriPort must meet the following conditions: 1. when CN is set to 0, SRN must be set to 0~1, 4~5 or 60~254; 2. when CN is set to 1~7, SRN must be set to 0~1, 4~5; 3. when CN is set to 8~62, SRN must be set to 4~5; 4. when SRN is set to 0~1, SN must be set to Read Only 0~7; 5. when SRN is set to 4~5 and TYPE in the Cabinet is equal to BTS3900AL, SN must be set to 0~8; 6. when SRN is set to 4~5 and TYPE in the Cabinet is not equal to BTS3900AL, SN must be set to 0~5; 7. when SRN is set to 60~254, SN must be set to 0.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

ET in the Equipment MO must be later than ST.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

ET in the Equipment MO must be later than ST.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the Equipment MO, the value of DVAH must be Read & Write smaller than or equal to the value of DVAL minus 5.

No (And no impact on the UE in idle mode)

N/A

N/A

In the Equipment MO, the value of DVAH must be Read & Write smaller than or equal to the value of DVAL minus 5.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

TYPE in the Subrack MO can be set to PMU only when TYPE in the Cabinet MO is set to one of the following values: APM30, PS4890, OMB, BTS3900, VIRTUAL, TP48600A, and BTS3900AL. TYPE in the Subrack MO can be set to TCU only when TYPE in the Cabinet MO is set Read & Write to one of the following values: APM30, OMB, TMC, BBC, VIRTUAL, TP48600A, and BTS3900AL. TYPE in the Subrack MO can be set to FMU only when TYPE in the Cabinet MO is set to one of the following values: RFC, BTS3900, BTS3900L, VIRTUAL,

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

When the value of CN ranges from 0 to 7 and SRN is set to 0 or 1, TYPE in the Subrack MO can be set to BBU3900. When the value of CN ranges from 0 to 62 and SRN is set Read Only to 4 or 5, TYPE in the Subrack MO must be set to RFU. In a Subrack MO, when TYPE is set to BBU3900, the value of CN must be smaller than or equal to 7. SRN in the BBU subrack MO must be set to 0 when TYPE in the Cabinet MO is set to OMB. In a Subrack MO, when TYPE is set to BBU3900, SRN must be set to 0 or 1. In a Subrack MO, when TYPE is set to RFU, SRN must be set to 4 or 5. In a Subrack MO, Read Only when TYPE is set to TCU, SRN must be set to 8 or 14. In a Subrack MO, when TYPE is set to FMU, SRN must be set to 11 or 12. In a Subrack MO, when TYPE is set to EMU, the value of SRN must range from 40 to 59. In a Subrack MO, when TYPE is set to PMU, SRN must be set to 7.

N/A

N/A

N/A

N/A

N/A

N/A

TYPE in the Subrack MO can be set to PMU only when TYPE in the Cabinet MO is set to one of the following values: APM30, PS4890, OMB, BTS3900, VIRTUAL, TP48600A, and BTS3900AL. TYPE in the Subrack MO can be set to TCU only when TYPE in the Cabinet MO is set Read Only to one of the following values: APM30, OMB, TMC, BBC, VIRTUAL, TP48600A, and BTS3900AL. TYPE in the Subrack MO can be set to FMU only when TYPE in the Cabinet MO is set to one of the following values: RFC, BTS3900, BTS3900L, VIRTUAL,

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

The manager unit of an EMU MO must be one of the following: 1. A Subrack MO with the value of SRN smaller than or Read & Write equal to 1; 2. A RRU MO with the value of SRN ranging from 60 to 254; 3. A CCU MO with SRN set to 15. In an EMU MO, when MSRN is set to 15, the value of MPN must be smaller than or equal to 7. When the value of MSRN is greater than or Read & Write equal to 60, the value of MPN must be equal to 0. When the value of MSRN is smaller than or equal to 1, the value of MPN must be smaller than or equal to 1.

N/A

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an EMU MO, the value of TUTHD minus the value of Read & Write TLTHD must be greater than or equal to 3.

No (And no impact on the UE in idle mode)

N/A

N/A

In an EMU MO, the value of TUTHD minus the value of Read & Write TLTHD must be greater than or equal to 3.

No (And no impact on the UE in idle mode)

N/A

N/A

In an EMU MO, the value of HUTHD minus the value of Read & Write HLTHD must be greater than or equal to 5. In an EMU MO, the value of HUTHD minus the value of Read & Write HLTHD must be greater than or equal to 5.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

The manager unit of a FMU MO must be one of the following: 1. A Subrack MO with the value of SRN smaller than or Read & Write equal to 1; 2. A RRU MO with the value of SRN ranging from 60 to 254; 3. A CCU MO with SRN set to 15.

N/A

N/A

N/A

In a FMU MO, when MSRN is set to 15, the value of MPN must be smaller than or equal to 7. When the value of MSRN is greater than or equal to 60, Read & Write the value of MPN must be equal to 0. When the value of MSRN is smaller than or equal to 1, the value of MPN must be smaller than or equal to 1.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

SRN in a TCU MO can be set to 14 only when TYPE in Read Only the Cabinet MO where the TCU MO is located is set to VIRTUAL.

N/A

N/A

N/A

SN in the TCU MO must be set to 0 when TYPE in a Cabinet MO where the TCU MO is located is set to VIRTUAL, APM30, TMC, or OMB. SN in the TCU MO Read Only must be set to a value smaller than 3 when TYPE in a Cabinet MO where the TCU MO is located is set to BBC or BTS3900AL.

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

The manager unit of a TCU MO must be one of the following: 1. A Subrack MO with the value of SRN smaller than or Read & Write equal to 1; 2. A RRU MO with the value of SRN ranging from 60 to 254; 3. A CCU MO with SRN set to 15.

N/A

N/A

N/A

In a TCU MO, when MSRN is set to 15, the value of MPN must be smaller than or equal to 7. When the value of MSRN is greater than or equal to 60, Read & Write the value of MPN must be equal to 0. When the value of MSRN is smaller than or equal to 1, the value of MPN must be smaller than or equal to 1.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the HtCDPa MO, the value of HTCP Read & Write must be greater than LTCP. In the HtCDPa MO, the value of HTCP Read & Write must be greater than LTCP.

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

The manager unit of a PMU MO must be one of the following: 1. A Subrack MO with the value of SRN smaller than or Read & Write equal to 1; 2. A RRU MO with the value of SRN ranging from 60 to 254; 3. A CCU MO with SRN set to 15.

N/A

N/A

N/A

In a PMU MO, when MSRN is set to 15, the value of MPN must be smaller than or equal to 7. When the value of MSRN is greater than or equal to 60, Read & Write the value of MPN must be equal to 0. When the value of MSRN is smaller than or equal to 1, the value of MPN must be smaller than or equal to 1.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

DCVLTHD in the PMU MO must be greater than 430 under the following conditions: 1. PTYPE in the PMU MO is set to a value other than SC48200; 2. The PMU MO does not have a lower-level Battery MO; 3. LSDF is set to DISABLE. LSDV in the PMU MO must be greater than 430 under the Read Only following conditions: 1. PTYPE in the PMU MO is set to a value other than SC48200; 2. The PMU MO does not have a lower-level Battery MO; 3. LSDF is set to ENABLE. In the PMU MO, DCVLTHD must be smaller than 515 when PTYPE is set to a value other than SC48200 and there is no lowerIn a PMU MO, when PTYPE is not set to SC48200, the value Read & Write of ACVLTHD must be smaller than ACVUTHD.

N/A

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In a PMU MO, when PTYPE is not set to SC48200, the value Read & Write of ACVLTHD must be smaller than ACVUTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

DCVLTHD in the PMU MO must be greater than 430 under the following conditions: 1. PTYPE in the PMU MO is set to a value other than SC48200; 2. The PMU MO does not have a lower-level Battery MO; 3. LSDF is set to DISABLE. In the PMU MO, DCVLTHD must be smaller than 515 Read & Write when PTYPE is set to a value other than SC48200 and there is no lowerlevel Battery MO. In a PMU MO, when PTYPE is set to a value other than SC48200, FCV in the Battery MO corresponding to the PMU MO must be greater than DCVLTHD in the PMU MO plus 20. SDV in the Battery MO corresponding

No (And no impact on the UE in idle mode)

N/A

N/A

In a PMU MO, when PTYPE is set to SC48200, BCV in the Battery MO corresponding to the PMU MO must be smaller than or equal to DCVUTHD in the PMU MO minus 15. In a PMU MO, when PTYPE is set to a value other than SC48200, BCV in the Battery MO corresponding to the PMU MO must Read & Write be smaller than DCVUTHD in the PMU MO minus 10. In a PMU MO, when PTYPE is set to SC48200, the value of DCVLTHD must be greater than or equal to 460 and smaller than or equal to 500, and the value of DCVUTHD must be greater than or equal to 580 and smaller than or equal to 600.

No (And no impact on the UE in idle mode)

N/A

N/A

In the PMU MO, when PTYPE is set to SC48200, LSDF is set to ENABLE by default. When PTYPE is set to a value other than SC48200, LSDF is set to DISABLE by default. DCVLTHD in the PMU MO must be greater than 430 under the following conditions: 1. PTYPE in the PMU MO is set to a value Read & Write other than SC48200; 2. The PMU MO does not have a lower-level Battery MO; 3. LSDF is set to DISABLE. LSDV in the PMU MO must be greater than 430 under the following conditions: 1. PTYPE in the PMU MO is set to a value other than SC48200; 2. The PMU MO does not have a lower-level

No (And no impact on the UE in idle mode)

N/A

N/A

The LSDV is valid only when LSDF in the PMU MO is set to ENABLE. LSDV in the PMU MO must be greater than 430 under the following conditions: 1. PTYPE in the PMU MO is set to a value other than SC48200; 2. The PMU MO does not have a lower-level Battery MO; 3. LSDF is set to ENABLE. Read & Write LSDV in the PMU MO must be greater than or equal to SDV in the Battery MO plus 5 under the following conditions: 1. PTYPE in the PMU MO is set to SC48200; 2. LSDF in the PMU MO is set to ENABLE; 3. LVSDF in the Battery MO corresponding to the PMU MO is also set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a PMU MO, AHLTHD must be smaller than AHUTHD.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a PMU MO, AHLTHD must be smaller than AHUTHD.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If PTYPE in the upper-level PMU MO of the Battery MO is set to a value other than SC48200, INSTALLTYPE in the Battery MO must be set to INNER or OUTER. Read & Write If PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200, INSTALLTYPE in the Battery MO must be set to OUTER.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a PMU MO, when PTYPE is set to SC48200, BCV in the Battery MO corresponding to the PMU MO must be smaller than or equal to DCVUTHD in the PMU MO minus 15. In a PMU MO, when PTYPE is set to a value other than SC48200, BCV in the Battery MO corresponding to the PMU MO must Read & Write be smaller than DCVUTHD in the PMU MO minus 10. If PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200, BCV in the Battery MO must be greater than or equal to 542 and smaller than or equal to 575. If PTYPE in the upper-level PMU MO of the Battery MO is set to

No (And no impact on the UE in idle mode)

N/A

N/A

If PTYPE in the upper-level PMU MO of the Battery MO is set to a value other than SC48200, and BN in the Battery MO is 1, BC1 in the Battery MO must be greater than or equal to 5 and smaller than or equal to 5000; If PTYPE in the upperlevel PMU MO of the Battery MO is set to a value other Read & Write than SC48200, and BN in the Battery MO is 2, BC1 and BC2 in the Battery MO must be greater than or equal to 5 and smaller than or equal to 5000. If PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200, and BN in the Battery MO is 1, BC1 in the Battery MO must be greater than or

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the PMU MO, when PTYPE is set to SC48200, the actual value range of FCV is from 52 to 56.3. When PTYPE is set to a value other than SC48200, the actual value range of FCV is from 43.2 to 57.5. In a PMU MO, when PTYPE is set to a value other than SC48200, FCV in the Battery MO Read & Write corresponding to the PMU MO must be greater than DCVLTHD in the PMU MO plus 20. If PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200, FCV in the Battery MO must be greater than or equal to 520 and smaller than or equal to 563. If PTYPE in the upper-level PMU When PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200 and HTSDF in the Battery MO is set Read & Write to ENABLE, SDT in the Battery MO must be greater than or equal to 45 and smaller than or equal to 70.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In the PMU MO, when PTYPE is set to SC48200, the actual value range of SDT is from 45 to 70. When PTYPE is set to a value other than SC48200, the actual value range of SDT is from 40 to 70. The SDT is valid only when HTSDF in the Battery MO is set to ENABLE. SDT in the Battery MO must be greater Read & Write than TUTHD. If PTYPE in the upper-level PMU MO of the Battery MO is set to a value other than SC48200, SDT in the Battery MO must be greater than or equal to 40 and smaller than or equal to 70. When PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200 and

No (And no impact on the UE in idle mode)

N/A

N/A

LSDV in the PMU MO must be greater than or equal to SDV in the Battery MO plus 5 under the following conditions: 1. PTYPE in the PMU MO is set to SC48200; 2. LSDF in the PMU MO is set to ENABLE; 3. LVSDF in the Battery MO corresponding to the PMU MO is also set to ENABLE. Read & Write SDV in the Battery MO corresponding to the PMU MO must be smaller than DCVLTHD in the PMU under the following conditions: 1. LSDF in the PMU MO is set to DISABLE; 2. LVSDF in the Battery MO corresponding to the PMU MO is set to ENABLE; 3. PTYPE in the PMU MO is set to a value

No (And no impact on the UE in idle mode)

N/A

N/A

The SDV is valid only when LVSDF in the Battery MO is set to ENABLE. LSDV in the PMU MO must be greater than or equal to SDV in the Battery MO plus 5 under the following conditions: 1. PTYPE in the PMU MO is set to SC48200; 2. LSDF in the PMU MO is set to ENABLE; 3. LVSDF in the Read & Write Battery MO corresponding to the PMU MO is also set to ENABLE. SDV in the Battery MO corresponding to the PMU MO must be smaller than DCVLTHD in the PMU under the following conditions: 1. LSDF in the PMU MO is set to DISABLE; 2. LVSDF in the Battery MO corresponding to If PTYPE in the upper-level PMU MO of the Battery MO is set to a value other than SC48200, TCC in the Battery MO must be smaller than or equal to 500. Read & Write If PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200, TCC in the Battery MO must be smaller than or equal to 100.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

TUTHD in the Battery MO must be greater than TLTHD,and be smaller than SDT. If PTYPE in the upper-level PMU MO of the Battery MO is set to a value other than SC48200, TUTHD in the Battery MO must be greater than or equal to 35 and smaller than or equal to 80. If PTYPE in the Read & Write upper-level PMU MO of the Battery MO is set to SC48200, TUTHD in the Battery MO must be greater than or equal to 35 and smaller than or equal to 60. When PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200 and HTSDF in the Battery MO is set to ENABLE, SDT The BN is valid only when BTYPE in the Battery MO is set Read & Write to LI_BAT. In TP48300A type PMU, Battery BN must be 1. None Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If PTYPE in the upper-level PMU MO of the Battery MO is set to a value other than SC48200, and BN in the Battery MO is 1, BC1 in the Battery MO must be greater than or equal to 5 and smaller than or equal to 5000; If PTYPE in the upperlevel PMU MO of the Battery MO is set to a value other Read & Write than SC48200, and BN in the Battery MO is 2, BC1 and BC2 in the Battery MO must be greater than or equal to 5 and smaller than or equal to 5000. If PTYPE in the upper-level PMU MO of the Battery MO is set to SC48200, and BN in the Battery MO is 1, BC1 in the Battery MO must be greater than or

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a BatCTPa MO, when ATMODE is set to PERIOD or PERIODPOWERC Read & Write UT, the value of TDSTM must be greater than the value of DDSTM.

No (And no impact on the UE in idle mode)

N/A

N/A

In a BatCTPa MO, when ATMODE is set to PERIOD or PERIODPOWERC Read & Write UT, the value of TDSTM must be greater than the value of DDSTM.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If PTYPE in the PMU MO is set to EPS4815, SN in the lower-level PSU MO must be set to 1 or 2. If PTYPE in the PMU MO is set to EPS48200, SN in the lower-level PSU MO must be greater than or equal to 1 and smaller than or equal to 4. If PTYPE in the PMU MO is set to TP48300A, SN in Read Only the lower-level PSU MO must be greater than or equal to 1 and smaller than or equal to 6. If PTYPE in the PMU MO is set to ETP, SN in the lower-level PSU MO must be greater than or equal to 1 and smaller than or equal to 7. If PTYPE in the PMU MO is not set to any of the following values, SN

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the AlmPort MO, PT must be set to BOOL when all the following conditions are met: 1. The device corresponding to the AlmPort MO is an EMU MO, and the value of SRN in this EMU MO ranges from 40 to 59; 2. The value of PN ranges from 0 to 31; 3. SW is set to ON.In the AlmPort MO, PT must be set Read Only to BOOL when all the following conditions are met: 1. The device corresponding to the AlmPort MO is not an EMU MO; 2. SW is set to ON. In the AlmPort MO, PT must be set to VALUE when all the following conditions are met: 1. The device corresponding to the AlmPort MO is an EMU MO, and

N/A

N/A

N/A

The AVOL is valid only when PT in the Read & Write AlmPort MO is set to BOOL.

No (And no impact on the UE in idle mode)

N/A

N/A

The UL is valid only when PT in the AlmPort MO is set to VALUE. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of UL must be Read & Write greater than the value of LL. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of SMUL must be greater than or equal to the value of UL.

No (And no impact on the UE in idle mode)

N/A

N/A

The LL is valid only when PT in the AlmPort MO is set to VALUE. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of UL must be Read & Write greater than the value of LL. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of SMLL must be smaller than or equal to the value of LL.

No (And no impact on the UE in idle mode)

N/A

N/A

In the AlmPort MO, the ST is valid only Read & Write when PT is set to VALUE.

No (And no impact on the UE in idle mode)

N/A

N/A

The SMUL is valid only when PT in the AlmPort MO is set to VALUE. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of SMUL must be greater Read & Write than the value of SMLL. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of SMUL must be greater than or equal to the value of UL. The SMLL is valid only when PT in the AlmPort MO is set to VALUE. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of SMUL must be greater Read & Write than the value of SMLL. In the AlmPort MO, when the values of SW and PT are set to ON and VALUE, respectively, the value of SMLL must be smaller than or equal to the value of LL.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

The SOUL is valid only when PT in the AlmPort MO is set to VALUE. In the AlmPort MO, when the values of SW and PT are set Read & Write to ON and VALUE, respectively, the value of SOUL must be greater than the value of SOLL. The SOLL is valid only when PT in the AlmPort MO is set to VALUE. In the AlmPort MO, when the values of SW and PT are set Read & Write to ON and VALUE, respectively, the value of SOUL must be greater than the value of SOLL. None Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

Each AAU MO must have a unique combination of CN, Read Only SRN, and SN among all MOs as follows: RRU, AAU. Each AAU MO must have a unique combination of CN, Read Only SRN, and SN among all MOs as follows: RRU, AAU. Each AAU MO must have a unique combination of CN, Read Only SRN, and SN among all MOs as follows: RRU, AAU.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

Yes

The cells carried on Till unblocking is the RRU or RFU is performed. unavailable.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When TT in the RRUCHAIN MO where the RRU MO or RFU MO is located is set to RING, one of the following conditions must be met: 1. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are not set to the same value and neither of them is set to 255, PS in the RRU MO or PS in the RFU MO must Read Only be greater than or equal to BRKPOS1 and be smaller than or equal to BRKPOS2; 2. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are set to the same value other than 255, PS in the RRU MO or PS in the RFU MO must be the same as BRKPOS1. When TT in the RRUCHAIN MO None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

Yes

Cell

<1

None

Read & Write

Yes

Cell

<1

None

Read & Write

Yes

Until the execution Services carried by of the MOD RRU the RRU or RFU command is successful

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

The cells carried on Till unblocking is the RRU or RFU is performed. unavailable.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When TT in the RRUCHAIN MO where the RRU MO or RFU MO is located is set to RING, one of the following conditions must be met: 1. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are not set to the same value and neither of them is set to 255, PS in the RRU MO or PS in the RFU MO must Read Only be greater than or equal to BRKPOS1 and be smaller than or equal to BRKPOS2; 2. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are set to the same value other than 255, PS in the RRU MO or PS in the RFU MO must be the same as BRKPOS1. When TT in the RRUCHAIN MO None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

Yes

Cell

<1

None

Read & Write

Yes

Cell

<1

None

Read & Write

Yes

Until the execution Services carried by of the MOD RRU the RRU or RFU command is successful

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When the value of SN in the RFU MO is greater than 5, TYPE in the corresponding Cabinet MO must be set to BTS3900AL.

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

The cells carried on the RRU are <1 unavailable.

None

Read & Write

Yes

The cells carried on Till unblocking is the RRU or RFU is performed. unavailable.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When TT in the RRUCHAIN MO where the RRU MO or RFU MO is located is set to RING, one of the following conditions must be met: 1. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are not set to the same value and neither of them is set to 255, PS in the RRU MO or PS in the RFU MO must Read Only be greater than or equal to BRKPOS1 and be smaller than or equal to BRKPOS2; 2. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are set to the same value other than 255, PS in the RRU MO or PS in the RFU MO must be the same as BRKPOS1. When TT in the RRUCHAIN MO None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

Yes

Cell

<1

None

Read & Write

Yes

Cell

<1

None

Read & Write

Yes

Until the execution Services carried by of the MOD RRU the RRU or RFU command is successful

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

Each RRU MO must have a unique combination of CN, Read Only SRN, and SN among all RRU MOs. Each RRU MO must have a unique combination of CN, Read Only SRN, and SN among all RRU MOs. Each RRU MO must have a unique combination of CN, Read Only SRN, and SN among all RRU MOs.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The RRU MO needs to be reset after the RT of this RRU MO is changed. In the RRU MO, RT must be set to Read & Write MRRU or LRRU when RS is set to LTE_TDD. In the RRU MO, RT must be set to MRRU when RS is set to WiMAX_LTE. None None Read Only Read Only

Yes

The cells carried on the RRU are <1 unavailable.

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

The cells carried on Till unblocking is the RRU or RFU is performed. unavailable.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When TT in the RRUCHAIN MO where the RRU MO or RFU MO is located is set to RING, one of the following conditions must be met: 1. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are not set to the same value and neither of them is set to 255, PS in the RRU MO or PS in the RFU MO must Read Only be greater than or equal to BRKPOS1 and be smaller than or equal to BRKPOS2; 2. When BRKPOS1 and BRKPOS2 in the RRUCHAIN MO are set to the same value other than 255, PS in the RRU MO or PS in the RFU MO must be the same as BRKPOS1. When TT in the RRUCHAIN MO None Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

Yes

Cell

<1

None

Read & Write

Yes

Cell

<1

None

Read & Write

Yes

Until the execution Services carried by of the MOD RRU the RRU or RFU command is successful

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

All MOs must be removed from the RRUCHAIN MO before the values of TT and BM in the RRUCHAIN MO are changed. In the RRUCHAIN MO, when TT is set to RING and this value needs to be changed, BRKPOS2 must be the same as the total number of MOs configured on the trunk of the Read & Write RRU chain or ring. In the RRUCHAIN MO, when TT is changed, BRKPOS1 must be set to 0. In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, WM in the BBP MO corresponding to HCN, HSRN, and HSN must be the same as the WM in the BBP MO corresponding to

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

When TT in the RRUCHAIN MO is set to CHAIN, BM must be set to COLD. When TT in Read & Write the RRUCHAIN MO is set to RING, BM can be set to COLD or HOT.

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the following conditions: 1. When TT in the RRUCHAIN MO is set to RING or Read & Write LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of TCN, TSRN, TSN, and TPN must be available; 3. When

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the following conditions: 1. When TT in the RRUCHAIN MO is set to RING or Read & Write LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of TCN, TSRN, TSN, and TPN must be available; 3. When

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the following conditions: 1. When TT in the RRUCHAIN MO is set to RING or Read & Write LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of TCN, TSRN, TSN, and TPN must be available; 3. When

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the following conditions: 1. When TT in the RRUCHAIN MO is set to RING or Read & Write LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of TCN, TSRN, TSN, and TPN must be available; 3. When

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

When TT in the RRUCHAIN MO is set to RING, TCN is valid. In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the Read & Write following conditions: 1. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

When TT in the RRUCHAIN MO is set to RING, TSRN is valid. In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the Read & Write following conditions: 1. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

When TT in the RRUCHAIN MO is set to RING, TSN is valid. In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the Read & Write following conditions: 1. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

When TT in the RRUCHAIN MO is set to RING, TPN is valid. In the RRUCHAIN MO, when TT is set to RING or LOADBALANCE, the combination of HCN, HSRN, HSN, and HPN cannot be the same as the combination of TCN, TSRN, TSN, and TPN. A RRUCHAIN MO must meet the Read & Write following conditions: 1. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the combination of HCN, HSRN, HSN, and HPN must be available; 2. When TT in the RRUCHAIN MO is set to RING or LOADBALANCE, the CpriPort MO specified by the

Yes

The cells carried by the RRUs on the RRU chain/ring are unavailable.

After the command takes effect, the cells carried by the RRUs on the RRU chain/ring become available.

In the RRUCHAIN MO, when TT is not set to CHAIN and BRKPOS1 is not set to 255, BRKPOS2 cannot be set to 255. In the RRUCHAIN MO, when TT is not set to CHAIN and BRKPOS1 is set to 255, BRKPOS2 must be set to 255. In the RRUCHAIN MO, when TT is not set to CHAIN, BRKPOS1 must be Read & Write smaller than or equal to BRKPOS2. If BRKPOS1 or BRKPOS2 in the RRUCHAIN MO is not set to 255, the values of BRKPOS1 and BRKPOS2 must be smaller than or equal to the total number of RRU and RFU MOs on the trunk of the RRU chain or ring. In a RRUCHAIN MO, when AT is set

Yes

The cells carried by the RRUs behind the breakpoint on the RRU chain become unavailable. The cells carried by the RRUs between breakpoints 1 and 2 on the RRU ring become unavailable.

The cells carried by the RRUs on the RRU chain/ring become available after the breakpoints are removed.

In the RRUCHAIN MO, when TT is set to CHAIN, BRKPOS2 must be set to 255. In the RRUCHAIN MO, when TT is not set to CHAIN and BRKPOS1 is not set to 255, BRKPOS2 cannot be set to 255. In the RRUCHAIN MO, when TT is not set to CHAIN and BRKPOS1 is set to 255, BRKPOS2 Read & Write must be set to 255. In the RRUCHAIN MO, when TT is not set to CHAIN, BRKPOS1 must be smaller than or equal to BRKPOS2. If BRKPOS1 or BRKPOS2 in the RRUCHAIN MO is not set to 255, the values of BRKPOS1 and BRKPOS2 must be smaller than or equal to the total number of RRU and

Yes

The cells carried by the RRUs between the breakpoints 1 and 2 on the RRU ring are unavailable.

The cells carried by the RRUs on the RRU chain/ring become available after the breakpoints are removed.

In a RRUCHAIN MO, when AT is set to PEERPORT, TT must be set to CHAIN. In the RRUCHAIN MO, HSN must be set to 2 or 3 if AT is set to PEERPORT. When AT in the RRUCHAIN is set to PEERPORT, the RS in the RRU on this RRUCHAIN must be set to LTE_FDD or UMTS_ONLY, or Read & Write UMTS_LTE, and the RT in the RRU on this RRUCHAIN must be set to MRRU or PRRU. In a RRUCHAIN MO, when AT is set to PEERPORT, CR must be set to AUTO. When AT in the RRUCHAIN MO is set to PEERPORT, the board specified by HSN must have not been configured.

N/A

N/A

N/A

None

Read & Write

Yes

Services are restored Cells carried on the immediately after RRU chain. the RRU finishes negotiating this rate with the BBU.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

CN,SRN and SN in the RxBranch must meet the following conditions: 1.when CN is set to 0, SRN must be set to 4~5 or 60~254; 2.when CN is set to 1~62, Read Only SRN must be set to 4~5; 3.when SRN is set to 4~5, SN must be set to 0~8; 4.when SRN is set to 60~254, SN must be set to 0.

N/A

N/A

N/A

CN,SRN and SN in the RxBranch must meet the following conditions: 1.when CN is set to 0, SRN must be set to 4~5 or 60~254; 2.when CN is set to 1~62, Read Only SRN must be set to 4~5; 3.when SRN is set to 4~5, SN must be set to 0~8; 4.when SRN is set to 60~254, SN must be set to 0. CN,SRN and SN in the RxBranch must meet the following conditions: 1.when CN is set to 0, SRN must be set to 4~5 or 60~254; 2.when CN is set to 1~62, Read Only SRN must be set to 4~5; 3.when SRN is set to 4~5, SN must be set to 0~8; 4.when SRN is set to 60~254, SN must be set to 0. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

Yes

Services on the channel are affected.

When the logical switch of RX channel is ON

When the TMA MO is not used, ATTEN in the RxBranch MO is set to 0. When the 12dB TMA MO is used, the value of ATTEN Read & Write ranges from 4 dB to 11 dB. When the 24dB TMA MO is used, the value of ATTEN ranges from 11 dB to 22 dB.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

CN, SRN and SN in the TxBranch must meet the following conditions: 1.when CN is set to 0, SRN must be set to 4~5 or 60~254; 2.when CN is set to 1~62, Read Only SRN must be set to 4~5; 3.when SRN is set to 4~5, SN must be set to 0~8; 4.when SRN is set to 60~254, SN must be set to 0. CN, SRN and SN in the TxBranch must meet the following conditions: 1.when CN is set to 0, SRN must be set to 4~5 or 60~254; 2.when CN is set to 1~62, Read Only SRN must be set to 4~5; 3.when SRN is set to 4~5, SN must be set to 0~8; 4.when SRN is set to 60~254, SN must be set to 0.

N/A

N/A

N/A

N/A

N/A

N/A

CN, SRN and SN in the TxBranch must meet the following conditions: 1.when CN is set to 0, SRN must be set to 4~5 or 60~254; 2.when CN is set to 1~62, Read Only SRN must be set to 4~5; 3.when SRN is set to 4~5, SN must be set to 0~8; 4.when SRN is set to 60~254, SN must be set to 0.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Services carried on the specified TX Less than 2 minutes channel

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None None

Read Only Read Only Read Only

N/A N/A N/A

N/A N/A N/A

N/A N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when Read Only MODE in the NtpCp MO is IPV4.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when Read Only MODE in the NtpCp MO is IPV6.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when AUTHMODE is set Read & Write to a value other than PLAIN.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO is set to YES.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When DST in the TZ MO is set to YES, SMONTH should not be equal to EMONTH. Read & Write This parameter is valid only when DST in the TZ MO is set to YES and SM is DATEWEEK, DATE, or WEEK. When DST in the TZ MO is set to YES and SM is DATEWEEK, SDAY plus 6 should not be beyond the end of the month specified by SMONTH. When DST in the TZ MO is set to Read & Write YES and SM is DATE, if SMONTH is FEB, then SDAY should not be greater than 28. This parameter is valid only when DST in the TZ MO is set to YES and SM is DATEWEEK or DATE.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO is set to YES and SM is WEEK.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO Read & Write is set to YES and SM is DATEWEEK or WEEK.

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO is set to YES.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO is set to YES.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO is set to YES and EM is DATEWEEK, DATE, or WEEK. Read & Write When DST in the TZ MO is set to YES, SMONTH and EMONTH are not allowed to be identical.

No (And no impact on the UE in idle mode)

N/A

N/A

When DST in the TZ MO is set to YES and EM is DATEWEEK, EDAY plus 6 should not be beyond the end of the month specified by EMONTH. This parameter is valid only when Read & Write DST in the TZ MO is set to YES and EM is DATEWEEK or DATE. When DST in the TZ MO is set to YES and EM is DATE, if EMONTH is FEB, then EDAY should not be greater than 28. This parameter is valid only when DST in the TZ MO Read & Write is set to YES and EM is WEEK. This parameter is valid only when DST in the TZ MO Read & Write is set to YES and EM is DATEWEEK or WEEK. This parameter is valid only when DST in the TZ MO is set to YES.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when DST in the TZ MO is set to YES.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when ZONET in the TZ MO is set to CUSTOM.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the FTPCLTPORT MO, Read Only SERVERIP cannot be set to 255.x.x.x.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the ENodeBIntegrityC ap MO, the PrimaryIntegrityAl go, SecondIntegrityAl Read & Write go, and ThirdIntegrityAlgo parameters must be set to different values.

No (And no impact on the UE in idle mode)

N/A

N/A

In the ENodeBIntegrityC ap MO, the PrimaryIntegrityAl go, SecondIntegrityAl Read & Write go, and ThirdIntegrityAlgo parameters must be set to different values.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a CellDrxPara MO, the value of TddEnterDrxThdUl Read & Write must be smaller than that of TddExitDrxThdUl.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a CellDrxPara MO, the value of TddEnterDrxThdDl Read & Write must be smaller than that of TddExitDrxThdDl.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If the threshold specified through this parameter is higher than the associated threshold for the coverage-based inter-RAT handover and the coveragebased handover is enabled, the Read & Write coverage-based handover takes precedence over both the load- and service-based handovers. In this case, the load- and service-based handovers would not occur.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

1. The value of InterFreqHoA2ThdR srp must be smaller than that of InterFreqHoA1ThdR srp. 2. In an Read & Write InterFreqHoGroup MO, the value of InterFreqHoA1Thd Rsrp must be larger than or equal to InterFreqHoA2Thd Rsrp.

No (And no impact on the UE in idle mode)

N/A

N/A

1. The value of InterFreqHoA2ThdR srq must be smaller than that of InterFreqHoA1ThdR srq. 2. In an Read & Write InterFreqHoGroup MO, the value of InterFreqHoA1Thd Rsrq must be larger than or equal to InterFreqHoA2Thd Rsrq.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

eNodeB

None

Read & Write

Yes

eNodeB

None

Read & Write

Yes

eNodeB

None

Read Only

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

eNodeB

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (After an S1 interface is blocked, UEs in idle mode N/A cannot access the network.) N/A N/A

N/A

None

Read Only

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

eNodeB

0.1

None

Read & Write

Yes

eNodeB

0.1

None

Read & Write

Yes

eNodeB

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If this parameter is set to REDIRECTION for a bearer with a QCI Read & Write of 1, call drop occurs during a redirection.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only for QCIs 6 Read & Write to 9.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when the beamforming Read & Write algorithm is enabled.

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when BfMimoAdaptiveSwi Read & Write tch is set to NO_ADAPTIVE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when the beamforming Read & Write algorithm is disabled.

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when MimoAdaptiveSwitc Read & Write h is set to NO_ADAPTIVE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

If this parameter is set to CFG, the AcBarringForEmerg ency, AcBarringForMoDat aCfgInd, and AcBarringForMoSig CfgInd parameters must be set. If this parameter is Read & Write set to NOT_CFG, the AcBarringForEmerg ency, AcBarringForMoDat aCfgInd, and AcBarringForMoSig CfgInd parameters do not need to be set.

No (For the UE in idle mode, this parameter is used with other parameters related to cell access barring to control the UE accesses.)

N/A

N/A

AcBarringForEmerg ency is optional, depending on the Read & Write setting of AcBarringInfoCfgIn d.

No (For the UE in idle mode, if it is BOOLEAN_TRUE, the emergency calls initiated by the UEs N/A of access categories 0 to 9 or UEs without IMSI are rejected.)

N/A

AcBarringForMoDat aCfgInd is optional, depending on the Read & Write setting of AcBarringInfoCfgIn d.

No (The access request of the mobile-originated call initiated by a UE in idle mode is accepted or rejected according to the corresponding barring status.)

N/A

N/A

AcBarringFactorFor Call is optional, depending on the Read & Write setting of AcBarringForMoDat aCfgInd.

No (For the UE in idle mode, the source call accesses are allowed only when N/A the random number generated by the UE is smaller than the access probability factor.)

N/A

AcBarTimeForCall is optional, depending on the Read & Write setting of AcBarringForMoDat aCfgInd.

No (And no impact on the UE in idle mode)

N/A

N/A

AC11BarforCall is optional, depending on the setting of Read & Write AcBarringForMoDat aCfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, N/A UEs of access class 11 are not allowed to initiate calls.)

N/A

AC12BarforCall is optional, depending on the setting of Read & Write AcBarringForMoDat aCfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, the mobileN/A originated calls initiated by UEs of access class 12 are not allowed.)

N/A

AC13BarforCall is optional, depending on the setting of Read & Write AcBarringForMoDat aCfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, the mobileN/A originated calls initiated by UEs of access class 13 are not allowed.)

N/A

AC14BarforCall is optional, depending on the setting of Read & Write AcBarringForMoDat aCfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, the mobileN/A originated calls initiated by UEs of access class 14 are not allowed.)

N/A

AC15BarforCall is optional, depending on the setting of Read & Write AcBarringForMoDat aCfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, the mobileN/A originated calls initiated by UEs of access class 15 are not allowed.)

N/A

1. If AcBarringForMoSig CfgInd is set to CFG, the following parameters need to be set: AcBarringFactorFor Sig, AcBarTimeForSig, AC11BarforSig, AC12BarforSig, AC13BarforSig, AC14BarforSig, and AC15BarforSig. If AcBarringForMoSig CfgInd is set to Read & Write CFG, the following parameters do not need to be set: AcBarringFactorFor Sig, AcBarTimeForSig, AC11BarforSig, AC12BarforSig, AC13BarforSig, AC14BarforSig, and AC15BarforSig. 2. AcBarringForMoSig CfgInd is optional, depending on the setting of AcBarringInfoCfgIn

No (The access request of the signaling initiated by a UE in idle mode is accepted or N/A rejected according to the corresponding barring status.)

N/A

AcBarringFactorFor Sig is optional, depending on the Read & Write setting of AcBarringForMoSig CfgInd.

No (The signaling initiated by a UE in idle mode is granted access only when the random number N/A generated by the UE is smaller than the access probability factor.)

N/A

AcBarTimeForSig is optional, depending on the setting of Read & Write AcBarringForMoSig CfgInd.

No (And no impact on the UE in idle mode)

N/A

N/A

AC11BarForSig is optional, depending on the setting of Read & Write AcBarringForMoSig CfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, N/A the signaling access initiated by UEs of access class 11 are not allowed.)

N/A

AC12BarForSig is optional, depending on the setting of Read & Write AcBarringForMoSig CfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, N/A the signaling access initiated by UEs of access class 12 are not allowed.)

N/A

AC13BarForSig is optional, depending on the setting of Read & Write AcBarringForMoSig CfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, N/A the signaling access initiated by UEs of access class 13 are not allowed.)

N/A

AC14BarForSig is optional, depending on the setting of Read & Write AcBarringForMoSig CfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, N/A the signaling access initiated by UEs of access class 14 are not allowed.)

N/A

AC15BarForSig is optional, depending on the setting of Read & Write AcBarringForMoSig CfgInd.

No (For the UE in idle mode, if this parameter is set to BOOLEAN_TRUE, N/A the signaling access initiated by UEs of access class 15 are not allowed.)

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (Modifications on this parameter will affect the cell on N/A which the UE in idle mode camps.)

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (Modifications on this parameter will affect the cell on N/A which the UE in idle mode camps.)

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SpeedDepReselCfg Ind is set to CFG, the following parameters must be set: TEvaluation, THystNormal, NCellChangeMediu m, NCellChangeHigh, QHystSfMedium and QHystSfHigh. If Read & Write SpeedDepReselCfg Ind is set to NOT_CFG, the following parameters do not need to be set: TEvaluation, THystNormal, NCellChangeMediu m, NCellChangeHigh, QHystSfMedium and QHystSfHigh.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedDepReselCfg Ind. If SpeedDepReselCfg Ind is set to CFG, Read & Write TEvaluation must be set. If SpeedDepReselCfg Ind is set to NOT_CFG, TEvaluation does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedDepReselCfg Ind. If SpeedDepReselCfg Ind is set to CFG, Read & Write THystNormal must be set. If SpeedDepReselCfg Ind is set to NOT_CFG, THystNormal does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedDepReselCfg Ind. If SpeedDepReselCfg Ind is set to CFG, QHystSfMedium Read & Write must be set. If SpeedDepReselCfg Ind is set to NOT_CFG, QHystSfMedium does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedDepReselCfg Ind. If SpeedDepReselCfg Ind is set to CFG, Read & Write QHystSfHigh must be set. If SpeedDepReselCfg Ind is set to NOT_CFG, QHystSfHigh does not need to be set. If SNonIntraSearchCf gInd is set to CFG, SNonIntraSearch must be set. If Read & Write SNonIntraSearchCf gInd is set to NOT_CFG, SNonIntraSearch does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SNonIntraSearchCf gInd. If SNonIntraSearchCf gInd is set to CFG, SNonIntraSearch Read & Write needs to be set. If SNonIntraSearchCf gInd is set to NOT_CFG, SNonIntraSearch does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If PMaxCfgInd is set to CFG, PMax must be set. If PMaxCfgInd is set Read & Write to NOT_CFG, PMax does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of PMaxCfgInd. If PMaxCfgInd is set to CFG, PMax must Read & Write be set. If PMaxCfgInd is set to NOT_CFG, PMax does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SIntraSearchCfgInd is set to CFG, SIntraSearch must be set. Read & Write If SIntraSearchCfgInd is set to NOT_CFG, SIntraSearch does not need to be set. This parameter is optional, depending on the setting of SIntraSearchCfgInd . If SIntraSearchCfgInd is set to CFG, Read & Write SIntraSearch needs to be set. If SIntraSearchCfgInd is set to NOT_CFG, SIntraSearch does not need to be set. If MeasBandWidthCfg Ind is set to CFG, MeasBandWidth must be set. If Read & Write MeasBandWidthCfg Ind is set to NOT_CFG, MeasBandWidth does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of MeasBandWidthCfg Ind. If MeasBandWidthCfg Ind is set to CFG, MeasBandWidth Read & Write must be set. If MeasBandWidthCfg Ind is set to NOT_CFG, MeasBandWidth does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SpeedStateSfCfgIn d is set to CFG, the following parameters must be set: TReselEutranSfMe dium and TReselEutranSfHig h. If Read & Write SpeedStateSfCfgIn d is set to NOT_CFG, the following parameters do not need to be set: TReselEutranSfMe dium and TReselEutranSfHig h. This parameter is optional, depending on the setting of SpeedStateSfCfgIn d. If SpeedStateSfCfgIn d is set to CFG, TReselEutranSfMe Read & Write dium must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselEutranSfMe dium does not need to be set. This parameter is optional, depending on the setting of the SpeedStateSfCfgIn d parameter. If SpeedStateSfCfgIn d is set to CFG, TReselEutranSfHig Read & Write h must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselEutranSfHig h does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If ThrshServLowQCfg Ind is set to CFG, this parameter must be set. If Read & Write ThrshServLowQCfg Ind is set to NOT_CFG, this parameter does not need to be set

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of ThrshServLowQCfg Ind. If ThrshServLowQCfg Ind is set to CFG, Read & Write this parameter must be set. If ThrshServLowQCfg Ind is set to NOT_CFG, this parameter does not need to be set If QQualMinCfgInd is set to CFG, this parameter must be set. Read & Write If QQualMinCfgInd is set to NOT_CFG, this parameter does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of QQualMinCfgInd. If QQualMinCfgInd is set to CFG, this Read & Write parameter must be set. If QQualMinCfgInd is set to NOT_CFG, this parameter does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read Only

N/A

N/A

N/A

If SysTimeCfgInd is set to CFG, CdmaEutraSyn must be set. If SysTimeCfgInd is Read & Write set to NOT_CFG, CdmaEutraSyn does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SysTimeCfgInd. If SysTimeCfgInd is set to CFG, CdmaEutraSyn Read & Write must be set. If SysTimeCfgInd is set to NOT_CFG, CdmaEutraSyn does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SearchWndSizeCfg Ind is set to CFG, SearchWndSize must be set. If Read & Write SearchWndSizeCfg Ind is set to NOT_CFG, SearchWndSize does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SearchWndSizeCfg Ind. If SearchWndSizeCfg Ind is set to CFG, SearchWndSize Read & Write must be set. If SearchWndSizeCfg Ind is set to NOT_CFG, SearchWndSize does not need to be set. If HrpdParamCfgInd is set to CFG, the following parameters must be set: HrpdPreRegistAllow ed, HrpdSecondPreReg istZoneId0Ind, and HrpdCellReselectPa ramCfgInd. Read & Write If HrpdParamCfgInd is set to NOT_CFG, the following parameters do not need to be set: HrpdPreRegistAllow ed, HrpdSecondPreReg istZoneId0Ind, and HrpdCellReselectPa ramCfgInd.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. This parameter is optional, depending on the setting of HrpdParamCfgInd. If HrpdParamCfgInd is set to CFG, HrpdCellReselectPa ramCfgInd must be set. If HrpdParamCfgInd is set to NOT_CFG, HrpdCellReselectPa ramCfgInd does not need to be set. 2 If HrpdCellReselectPa ramCfgInd is set to Read & Write CFG, the following parameters must be set: TreselectionHrpd and SpeedStateSfCfgIn d. If HrpdCellReselectPa ramCfgInd is set to NOT_CFG, the following parameters do not need to be set: TreselectionHrpd and SpeedStateSfCfgIn

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. If HrpdPreRegistAllow ed is set to BOOLEAN_TRUE, HrpdPreRegistZone Id must be set. If HrpdPreRegistAllow ed is set to BOOLEAN_FALSE, HrpdPreRegistZone Id does not need to be set. Read & Write 2. This parameter is optional, depending on the setting of HrpdParamCfgInd. If HrpdParamCfgInd is set to CFG, HrpdPreRegistAllow ed must be set. If HrpdParamCfgInd is set to NOT_CFG, HrpdPreRegistAllow ed does not need to be set. This parameter is optional, depending on the setting of HrpdPreRegistAllow ed. If HrpdPreRegistAllow ed is set to BOOLEAN_TRUE, Read & Write HrpdPreRegistZone Id must be set. If HrpdPreRegistAllow ed is set to BOOLEAN_FALSE, HrpdPreRegistZone Id does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. This parameter is optional, depending on the setting of HrpdParamCfgInd. If HrpdParamCfgInd is set to CFG, HprdSecondPreReg istZoneId0Ind must be set. If HrpdParamCfgInd is set to NOT_CFG, HprdSecondPreReg istZoneId0Ind does not need to be set. 2. If HrpdSecondPreReg istZoneId0Ind is set Read & Write to CFG, the following parameters must be set: HrpSecondPreRegi stZoneId0 and HrpdSecondPreReg istZoneId1Ind. If HrpdSecondPreReg istZoneId0Ind is set to NOT_CFG, the following parameters do not need to be set: HrpdSecondPreReg istZoneId0 and 1. This parameter is optional, depending on the setting of HprdSecondPreReg istZoneId0Ind. If HprdSecondPreReg istZoneId0Ind is set to CFG, HprdSecondPreReg Read & Write istZoneId0 must be set. If HprdSecondPreReg istZoneId0Ind is set to NOT_CFG, HprdSecondPreReg istZoneId0 does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. This parameter is optional, depending on the setting of HrpdSecondPreReg istZoneId0Ind. If HrpdSecondPreReg istZoneId0Ind is set to CFG, HrpdSecondPreReg istZoneId1Ind must be set. If HrpdSecondPreReg istZoneId0Ind is set to NOT_CFG, HrpdSecondPreReg Read & Write istZoneId1Ind does not need to be set. 2. If HrpdSecondPreReg istZoneId1Ind is set to CFG, HrpdSecondPreReg istZoneId1 must be set. If HrpdSecondPreReg istZoneId1Ind is set to NOT_CFG, HrpdSecondPreReg istZoneId1 does not need to be set. This parameter is optional, depending on the setting of HprdSecondPreReg istZoneId1Ind. If HprdSecondPreReg istZoneId1Ind is set to CFG, HprdSecondPreReg Read & Write istZoneId1 must be set. If HprdSecondPreReg istZoneId1Ind is set to NOT_CFG, HprdSecondPreReg istZoneId1 does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of HrpdCellReselectPa ramCfgInd. If HrpdCellReselectPa ramCfgInd is set to CFG, Read & Write TreselectionHrpd must be set. If HrpdCellReselectPa ramCfgInd is set to NOT_CFG, TreselectionHrpd does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. This parameter is optional, depending on the setting of HrpdCellReselectPa ramCfgInd. If HrpdCellReselectPa ramCfgInd is set to CFG, SpeedStateSfCfgIn d must be set. If HrpdCellReselectPa ramCfgInd is set to NOT_CFG, SpeedStateSfCfgIn d does not need to Read & Write be set. 2 If SpeedStateSfCfgIn d is set to CFG, the following parameters must be set: TReselCdmaHrpdSf Medium and TReselCdmaHrpdSf High. If SpeedStateSfCfgIn d is set to NOT_CFG, the following parameters do not

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedStateSfCfgIn d. If SpeedStateSfCfgIn d is set to CFG, TReselCdmaHprdSf Read & Write High must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselCdmaHprdSf High does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedStateSfCfgIn d. If SpeedStateSfCfgIn d is set to CFG, TReselCdmaHrpdSf Read & Write Medium must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselCdmaHrpdSf Medium does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If Cdma1XrttCfgInd is set to CFG, the following parameters must be set: Cdma1XrttCsfbReg CfgInd, Cdma1XrttLongCod eStateCfgInd, and Cdma1XrttCellRese lCfgInd. Read & Write If Cdma1XrttCfgInd is set to NOT_CFG, the following parameters do not need to be set: Cdma1XrttCsfbReg CfgInd, Cdma1XrttLongCod eStateCfgInd, and Cdma1XrttCellRese lCfgInd.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. If Cdma1XrttCsfbReg CfgInd is set to CFG, the following parameters need to be set: Cdma1XrttCsfbReg Sid, Cdma1XrttCsfbReg Nid, Cdma1XrttCsfbReg MultiSidInd, Cdma1XrttCsfbReg MultiNidInd, Cdma1XrttCsfbReg HomeRegInd, Cdma1XrttCsfbReg Read & Write ForeignSidRegInd, Cdma1XrttCsfbReg ForeignNidRegInd, Cdma1XrttCsfbReg ParamRegInd, Cdma1XrttCsfbReg PowerUpRegInd, Cdma1XrttCsfbReg RegPeriod, Cdma1XrttCsfbReg RegZone, Cdma1XrttCsfbReg TotalZone, Cdma1XrttCsfbReg ZoneTimer, Cdma1XrttCsfbPwr DownRegInd, and This parameter is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write Cdma1XrttCsfbReg Sid must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg Sid does not need to be set.

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write Cdma1XrttCsfbReg Nid must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg Nid does not need to be set. Cdma1XrttCsfbReg MultiSidInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write Cdma1XrttCsfbReg MultiSidInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg MultiSidInd does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

Cdma1XrttCsfbReg MultiNidInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write Cdma1XrttCsfbReg MultiNidInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg MultiNidInd does not need to be set. Cdma1XrttCsfbReg HomeRegInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write Cdma1XrttCsfbReg HomeRegInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg HomeRegInd does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

Cdma1XrttCsfbReg FrgnSidRegInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write FrgnSidRegInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg FrgnSidRegInd does not need to be set. Cdma1XrttCsfbReg FrgnNidRegInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write FrgnNidRegInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg FrgnNidRegInd does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

Cdma1XrttCsfbReg ParamRegInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write Cdma1XrttCsfbReg ParamRegInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg ParamRegInd does not need to be set. Cdma1XrttCsfbReg PowerUpRegInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write PowerUpRegInd must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg PowerUpRegInd does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write RegPeriod must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg RegPeriod does not need to be set. This parameter is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write RegZone must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg RegZone does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write TotalZone must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg TotalZone does not need to be set. This parameter is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Cdma1XrttCsfbReg Read & Write ZoneTimer must be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, Cdma1XrttCsfbReg ZoneTimer does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. If Cdma1XrttLongCod eStateCfgInd is set to CFG, Cdma1XrttLongCod eState must be set. If Cdma1XrttLongCod eStateCfgInd is set to NOT_CFG, Cdma1XrttLongCod eState does not need to be set. 2. Cdma1XrttLongCod Read & Write eStateCfgInd is optional, depending on the setting of Cdma1XrttCfgInd. If Cdma1XrttCfgInd is set to CFG, Cdma1XrttLongCod eStateCfgInd must be set. If Cdma1XrttCfgInd is set to NOT_CFG, Cdma1XrttLongCod eStateCfgInd does not need to be set. This parameter is optional, depending on the setting of Cdma1XrttLongCod eStateCfgInd. If Cdma1XrttLongCod eStateCfgInd is set to CFG, Read & Write Cdma1XrttLongCod eState must be set. If Cdma1XrttLongCod eStateCfgInd is set to NOT_CFG, Cdma1XrttLongCod eState does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. Cdma1XrttCellRese lCfgInd is optional, depending on the setting of Cdma1XrttCfgInd. If Cdma1XrttCfgInd is set to CFG, Cdma1XrttCellRese lCfgInd must be set. If Cdma1XrttCfgInd is set to NOT_CFG, Cdma1XrttCellRese lCfgInd does not need to be set. 2. If Cdma1XrttCellRese Read & Write lCfgInd is set to CFG, the following parameters must be set: Cdma1XrttTreselect ion and Cdma1XrttSpeedSt ateCfgInd. If Cdma1XrttCellRese lCfgInd is set to NOT_CFG, the following parameters do not need to be set: Cdma1XrttTreselect ion and This parameter is optional, depending on the setting of Cdma1XrttCellRese lCfgInd. If Cdma1XrttCellRese lCfgInd is set to CFG, Read & Write Cdma1XrttTreselect ion must be set. If Cdma1XrttCellRese lCfgInd is set to NOT_CFG, Cdma1XrttTreselect ion does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

1. Cdma1XrttSpeedSt ateCfgInd is optional, depending on the setting of Cdma1XrttCellRese lCfgInd. If Cdma1XrttCellRese lCfgInd is set to CFG, Cdma1XrttSpeedSt ateCfgInd must be set. If Cdma1XrttCellRese lCfgInd is set to Read & Write NOT_CFG, Cdma1XrttSpeedSt ateCfgInd does not need to be set. 2. If Cdma1XrttSpeedSt ateCfgInd is set to CFG, the following parameters must be set: Cdma1XrttSfMediu m and Cdma1XrttSfHigh. If Cdma1XrttSpeedSt ateCfgInd is set to NOT_CFG, the This parameter is optional, depending on the setting of Cdma1XrttSpeedSt ateCfgInd. If Cdma1XrttSpeedSt ateCfgInd is set to CFG, Read & Write Cdma1XrttSfMediu m must be set. If Cdma1XrttSpeedSt ateCfgInd is set to NOT_CFG, Cdma1XrttSfMediu m does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional. Whether to set this parameter is determined by the parameter Cdma1XrttSpeedSt ateCfgInd. When Cdma1XrttSpeedSt ateCfgInd is set to Read & Write CFG, Cdma1XrttSfHigh needs to be set. When Cdma1XrttSpeedSt ateCfgInd is set to NOT_CFG, Cdma1XrttSfHigh does not need to be set. CsfbRegPwrDownR egCfgInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, Read & Write CsfbRegPwrDownR egCfgInd needs to be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, CsfbRegPwrDownR egCfgInd does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

1. CsfbAcBarCfgInd is optional, depending on the setting of Cdma1XrttCsfbReg CfgInd. If Cdma1XrttCsfbReg CfgInd is set to CFG, CsfbAcBarCfgInd needs to be set. If Cdma1XrttCsfbReg CfgInd is set to NOT_CFG, CsfbAcBarCfgInd Read & Write does not need to be set. 2. If CsfbAcBarCfgInd is set to CFG, the following parameters need to be set: CsfbAcBar0to9, CsfbAcBar10, CsfbAcBar11, CsfbAcBar12, CsfbAcBar13, CsfbAcBar14, CsfbAcBar15, CsfbAcBarMsg, CsfbAcBarReg, and CsfbAcBar0to9 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, CsfbAcBar0to9 Read & Write needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar0to9 does not need to be set.

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

CsfbAcBar10 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, Read & Write CsfbAcBar10 needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar10 does not need to be set. CsfbAcBar11 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, Read & Write CsfbAcBar11 needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar11 does not need to be set. CsfbAcBar12 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, Read & Write CsfbAcBar12 needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar12 does not need to be set. CsfbAcBar13 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, Read & Write CsfbAcBar13 needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar13 does not need to be set.

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

CsfbAcBar14 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, Read & Write CsfbAcBar14 needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar14 does not need to be set. CsfbAcBar15 is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, Read & Write CsfbAcBar15 needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBar15 does not need to be set. CsfbAcBarMsg is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, CsfbAcBarMsg Read & Write needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBarMsg does not need to be set. CsfbAcBarReg is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, CsfbAcBarReg Read & Write needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBarReg does not need to be set.

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

CsfbAcBarEmg is optional, depending on the setting of CsfbAcBarCfgInd. If CsfbAcBarCfgInd is set to CFG, CsfbAcBarEmg Read & Write needs to be set. If CsfbAcBarCfgInd is set to NOT_CFG, CsfbAcBarEmg does not need to be set.

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SpeedStateSfCfgIn d is set to CFG, the following parameters must be set: TReselGeranSfMed ium and TReselGeranSfHigh . Read & Write If SpeedStateSfCfgIn d is set to NOT_CFG, the following parameters do not need to be set: TReselGeranSfMed ium and TReselGeranSfHigh

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedStateSfCfgIn d. If SpeedStateSfCfgIn d is set to CFG, TReselGeranSfMed Read & Write ium must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselGeranSfMed ium does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of SpeedStateSfCfgIn d. If SpeedStateSfCfgIn d is set to CFG, TReselGeranSfHigh Read & Write must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselGeranSfHigh does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SpeedStateSfCfgIn d is set to CFG, the following parameters must be set: TReselUtranSfMedi um and TReselUtranSfHigh. If Read & Write SpeedStateSfCfgIn d is set to NOT_CFG, the following parameters do not need to be set: TReselUtranSfMedi um and TReselUtranSfHigh.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of the SpeedStateSfCfgIn d parameter. If SpeedStateSfCfgIn d is set to CFG, TReselUtranSfMedi Read & Write um must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselUtranSfMedi um does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of the SpeedStateSfCfgIn d parameter. If SpeedStateSfCfgIn d is set to CFG, TReselUtranSfHigh Read & Write must be set. If SpeedStateSfCfgIn d is set to NOT_CFG, TReselUtranSfHigh does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell N/A selection of the UE in idle mode.)

N/A

If QQualMinOffsetCfg Ind is set to CFG, this parameter must be set. If Read & Write QQualMinOffsetCfg Ind is set to NOT_CFG, this parameter does not need to be set.

No (Modifications on this parameter would affect cell N/A selection of the UE in idle mode.)

N/A

This parameter is optional, depending on the setting of QQualMinOffsetCfg Ind. If QQualMinOffsetCfg Ind is set to CFG, Read & Write this parameter must be set. If QQualMinOffsetCfg Ind is set to NOT_CFG, this parameter does not need to be set.

No (Modifications on this parameter would affect cell N/A selection of the UE in idle mode.)

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the Cell MO, the value of CellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three plus signs (+++), two or more consecutive spaces, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

1. If UlEarfcnCfgInd is set to CFG, UlEarfcn must be set; If UlEarfcnCfgInd is set to NOT_CFG, UlEarfcn does not need to be set. 2. In the Cell MO, if Read & Write FddTddInd is set to CELL_TDD and UlEarfcnCfgInd is set to CFG, DlEarfcn and UlEarfcn must be set to the same value.

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

Until the cell is activated

None

Read & Write

Yes

Cell

Until the cell is unblocked

This parameter needs to be specified only when Read & Write the middle priority block is performed

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

If EmergencyAreaIdCf gInd is set to CFG, EmergencyAreaId must be set. If Read & Write EmergencyAreaIdCf gInd is set to NOT_CFG, EmergencyAreaId does not need to be set. EmergencyAreaId is optional, depending on the setting of EmergencyAreaIdCf gInd. If EmergencyAreaIdCf gInd is set to CFG, EmergencyAreaId Read & Write must be set. If EmergencyAreaIdCf gInd is set to NOT_CFG, EmergencyAreaId does not need to be set. If UePowerMaxCfgInd is set to CFG, UePowerMax must be set. Read & Write If UePowerMaxCfgInd is set to NOT_CFG, UePowerMax does not need to be set.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

This parameter is optional, depending on the setting of the UePowerMaxCfgInd parameter. If UePowerMaxCfgInd is set to CFG, Read & Write UePowerMax must be set. If UePowerMaxCfgInd is set to NOT_CFG, UePowerMax does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

If the CioAdjLimitCfgInd parameter is set to CFG, the CioAdjLowerLimit and CioAdjUpperLimit parameters need to be set. Read & Write If the CioAdjLimitCfgInd parameter is set to NOT_CFG, the CioAdjLowerLimit and CioAdjUpperLimit parameters do not need to be set.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

PresenceAntennaP ort1 must be set as Read & Write required.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

1. Let A be the value of UlBandWidth in the Cell MO, B the even number that HoppingOffset in the PUSCHCFG MO is rounded up to, and C the difference between A and B. If UlHoppingType in the CellUlschAlgo MO is set to HOPPING_TYPE1, C must be greater than UlBandWidth Read & Write in the Cell MO modulo 2. If UlHoppingType in the CellUlschAlgo MO is set to HOPPING_TYPE2 or HOPPING_TYPE2_ RANDOM, C modulo Nsb in the PUSCHCfg MO must be greater than 0. 2. If the switch for uplink ICIC in the frequency domain is turned on,

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If PrachConfigIndexCf gInd in the RACHCfg MO is set to NOT_CFG and RachAdjSwitch is turned on, the Read & Write RACH resources in the cell can be adaptively adjusted based on the access type and the number of access attempts.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter must be properly set so that two conditions are met: (1) The PRACH RBs are strictly confined in the cell bandwidth; (2) The Read & Write PRACH RBs and PUCCH RBs do not overlap. This parameter is valid only if PucchAlgoSwitch in the CellAlgoSwitch MO is turned off.

Yes

Cell

0.1

If RachAdjSwitch in the CellAlgoSwitch MO is turned on and this parameter Read & Write is set to CFG, this parameter takes precedence over RachAdjSwitch.

Yes

Cell

0.1

The setting of this parameter takes effect only if PrachConfigIndexCf gInd is set to CFG. Read & Write Otherwise, the parameter setting does not take effect.

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

Let A be the value of UlBandWidth in the Cell MO, B the even number that HoppingOffset in the PUSCHCFG MO is rounded up to, and C the difference between A and B. If UlHoppingType in the CellUlschAlgo MO is set to HOPPING_TYPE1, C must be greater Read & Write than UlBandWidth in the Cell MO modulo 2. If UlHoppingType in the CellUlschAlgo MO is set to HOPPING_TYPE2 or HOPPING_TYPE2_ RANDOM, C modulo Nsb in the PUSCHCfg MO must be greater than 0.

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

Let A be the value of UlBandWidth in the Cell MO, B the even number that HoppingOffset in the PUSCHCFG MO is rounded up to, and C the difference between A and B. If UlHoppingType in the CellUlschAlgo MO is set to HOPPING_TYPE1, C must be greater Read & Write than UlBandWidth in the Cell MO modulo 2. If UlHoppingType in the CellUlschAlgo MO is set to HOPPING_TYPE2 or HOPPING_TYPE2_ RANDOM, C modulo Nsb in the PUSCHCfg MO must be greater than 0.

Yes

Cell

0.1

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

Cell

0.1

This parameter can be set only if PucchAlgoSwitch in the CellAlgoSwitch MO is turned off. Read & Write Otherwise, the parameter setting does not take effect.

Yes

Cell

0.1

This parameter can be set only if PucchAlgoSwitch in the CellAlgoSwitch MO is turned off. Read & Write Otherwise, the parameter setting does not take effect.

Yes

Cell

0.1

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

LOFD-001021: PS Inter-RAT Mobility between LTE and CDMA2000

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the Cdma2000HrpdNc ell MO, the value of LocalCellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%). In the Cdma2000HrpdNc ell MO, the value of NeighbourCellNam e is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If SearchWindowSize CfgInd is set to Read & Write CFG, SearchWindowSize must be set.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the Cdma2000External Cell MO, the value of CellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the Cdma20001XRTTN cell MO, the value of LocalCellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%). In the Cdma20001XRTTN cell MO, the value of NeighbourCellNam e is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double Read & Write quotation marks ("), commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The greater the parameter, the greater the possibility for the UE to camp in this cell. The smaller the Read & Write parameter is, the smaller the possibility for the UE to camp in this cell.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When RacCfgInd is set to CFG, Rac must be set. When RacCfgInd is Read & Write set to NOT_CFG, Rac does not need to be set.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the GeranExternalCell MO, the value of CellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the GeranNcell MO, the value of LocalCellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%). In the GeranNcell MO, the value of NeighbourCellNam e is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If CellReselPriorityCfg Ind is set to CFG, Read & Write CellReselPriority must be set.

No (And no impact on the UE in idle mode)

N/A

N/A

If PmaxGeranCfgInd is set to CFG, PmaxGeran must be set. Read & Write If PmaxGeranCfgInd is set to NOT_CFG, PmaxGeran does not need to be set.

No (And no impact on the UE in idle mode)

N/A

N/A

If PmaxGeranCfgInd is set to CFG, PmaxGeran must be set. Read & Write If PmaxGeranCfgInd is set to NOT_CFG, PmaxGeran does not need to be set.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter cannot be the same as the physical cell Read Only identity of the serving cell.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The smaller the value of this parameter, the less probable that the UE camps on the neighboring cell during reselection. Read & Write The larger the value of this parameter, the more probable that the UE camps on the neighboring cell.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the EutranIntraFreqNC ell MO, the value of LocalCellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

In the EutranIntraFreqNC ell MO, the value of NeighbourCellNam e is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters: double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If CellReselPriorityCfg Ind is set to CFG, Read & Write CellReselPriority must be set.

No (Modifications on this parameter will affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SpeedDependSPCf gInd is set to CFG, Read & Write TReselEutranSfMe dium must be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If SpeedDependSPCf gInd is set to CFG, Read & Write TReselEutranSfHig h must be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

N/A

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

A larger value of this parameter leads to a lower probability of a cell meeting criteria S and becoming a suitable cell for cell selection. A smaller value of this Read & Write parameter leads to a higher probability. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If PmaxCfgInd is set to CFG, Pmax must Read & Write be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

If QqualMinCfgInd is set to CFG, this parameter must be set. Read & Write If QqualMinCfgInd is set to NOT_CFG, this parameter does not need to be set.

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read & Write

No (Modifications on this parameter would affect cell reselection of the UE in idle mode.)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

The smaller the value of this parameter, the less probable that the UE camps on the neighboring cell during reselection. Read & Write The larger the value of this parameter, the more probable that the UE camps on the neighboring cell.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the EutranInterFreqNC ell MO, the value of LocalCellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%). In the EutranInterFreqNC ell MO, the value of NeighbourCellNam e is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the EutranExternalCell MO, the value of CellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is optional, depending on the setting of Read & Write CellReselPriorityCfg Ind.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the UtranNCell MO, the value of LocalCellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%). In the UtranNCell MO, the value of NeighbourCellNam e is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is optional, depending on the setting of Read & Write CellReselPriorityCfg Ind.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

1. If UtranUlArfcnCfgInd is set to CFG, UtranUlArfcn must be set. Read & Write 2. The DL UARFCN and UL UARFCN must be in the same frequency band.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If CellReselPriorityCfg Ind is set to CFG, Read & Write CellReselPriority must be set.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Qqualmin must be set if UtranFddTddType is set to UTRAN_FDD.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

ThreshXHighQ must be set if UtranFddTddType is set to UTRAN_FDD.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

ThreshXLowQ must be set if UtranFddTddType Read & Write is set to UTRAN_FDD.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When UtranUlArfcnCfgInd is set to CFG, UtranUlArfcn must be set. If Read & Write UtranUlArfcnCfgInd is set to NOT_CFG, UtranUlArfcn does not need to be configured.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If RacCfgInd is set to CFG, this parameter must be set.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the UtranExternalCell MO, the value of CellName is a string of a maximum of 99 characters. The string cannot be all null characters or contain any of the following characters:double quotation marks ("), Read & Write commas (,), semicolons (;), equal signs (=), single quotation marks ('), three consecutive plus signs (+++), two or more consecutive blanks, and two or more consecutive percentage signs (%).

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Cells configured with punctured RBs and non-standard bandwidths support only static ICIC. If Read & Write adaptive DL ICIC is enabled, static and dynamic DL ICIC do not take effect.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If adaptive UL ICIC is enabled, static and dynamic UL Read & Write ICIC do not take effect.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

RTHD in the LICENSEALMTHD MO must be smaller Read & Write than or equal to OTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

RTHD in the LICENSEALMTHD MO must be smaller Read & Write than or equal to OTHD.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The total traffic proportions of all operations cannot exceed 100%.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The total traffic proportions of all operations cannot exceed 100%.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The total traffic proportions of all operations cannot exceed 100%.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The total traffic proportions of all operations cannot exceed 100%.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The value of this parameter cannot Read & Write exceed that of Operator1TrfRatio.

No (And no impact on the UE in idle mode)

N/A

N/A

The value of this parameter cannot Read & Write exceed that of Operator2TrfRatio.

No (And no impact on the UE in idle mode)

N/A

N/A

The value of this parameter cannot Read & Write exceed that of Operator3TrfRatio.

No (And no impact on the UE in idle mode)

N/A

N/A

The value of this parameter cannot Read & Write exceed that of Operator4TrfRatio.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

Cell

0.1

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

OBJTORSCGROU PID in an NODETORSCGRP MO must be Read Only different from that in any other NODETORSCGRP MO.

N/A

N/A

N/A

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In a NODETORSCGRP MO, ENDPOINTID is valid only when ISALLMATCH is set to NO. In a NODETORSCGRP MO, if S1X2FLAG is set to SGW, ENDPOINTID must Read & Write be set to a value in the range of 0 to 127. In a NODETORSCGRP MO, if S1X2FLAG is set to X2eNodeB, ENDPOINTID must be set to a value in the range of 16 to 79.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

SONSECPARANA ME in an SonSecPara MO Read Only must be different from that in any other SonSecPara MO.

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

In an SonSecPara MO, this parameter is valid only when Read & Write IKEVERSION is set to IKE_V1.

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

In an SonSecPara MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

In an SonSecPara MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

None

Read & Write

N/A

N/A

N/A

In an SonSecPara MO, this parameter is valid only when Read & Write LTCFG is set to LOCAL.

N/A

N/A

N/A

In an SonSecPara MO, this parameter is valid only when Read & Write LTCFG is set to LOCAL. CNOPERATORID in an SonSecPara MO must be the same as CnOperatorId in a configured CnOperator MO.

N/A

N/A

N/A

Read & Write

N/A

N/A

N/A

MMEID in an MME6 MO must be different from that in Read Only any other MME6 MO.

N/A

N/A

N/A

FIRSTSIGIP in an MME MO must be different from IP in any DEVIP MO, and cannot be set to 0.0.0.0. FIRSTSIGIP in each MME MO must be different Read & Write from FIRSTSIGIP or SECSIGIP in any other MME MO. FIRSTSIGIP in each MME MO must be different from FIRSTSIGIP or SECSIGIP in any X2eNodeB MO.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

FIRSTIKEPEERNM and FIRSTIPSECPROP NM are valid only when FIRSTIPSECFLAG is set to ENABLE. If Read & Write FIRSTIPSECFLAG in the MME MO is set to ENABLE, FIRSTIKEPEERNM must be the same as PEERNAME in a configured IKEPEER MO.

Yes

NE

Less than 1 minute

FIRSTIKEPEERNM and FIRSTIPSECPROP NM are valid only when the FIRSTIPSECFLAG parameter is set to ENABLE. If FIRSTIPSECFLAG Read & Write in the MME MO is set to ENABLE, FIRSTIPSECPROP NM must be the same as PROPNAME in a configured IPSECPROPOSAL MO. SECSIGIP in an MME MO is valid if it is not set to 0.0.0.0. This enables the MME to set up an SCTP link based on SCTP multi-homing with the local eNodeB. If SECSIGIP in an MME MO is set to a valid value, it must be different from IP in any DEVIP MO configured on the local eNodeB. If SECSIGIP in an Read & Write MME MO is set to a valid value, it must be different from FIRSTSIGIP in the same MO. If SECSIGIP in an MME MO is set to a valid value, it must be different from FIRSTSIGIP or SECSIGIP in any configured MME MO. If SECSIGIP in an MME MO is set to a valid value, it must be different from

Yes

NE

Less than 1 minute

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

SECIKEPEERNM and SECIPSECPROPN M are valid only when SECIKEPEERNM is set to ENABLE. If SECIPSECFLAG Read & Write in the MME MO is set to ENABLE, SECIKEPEERNM must be the same as PEERNAME in a configured IKEPEER MO. SECIKEPEERNM and SECIPSECPROPN M are valid only when the SECIKEPEERNM parameter is set to ENABLE. If SECIPSECFLAG Read & Write in the MME MO is set to ENABLE, SECIPSECPROPN M must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than 1 minute

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

CNOPERATORID in an MME MO must be the same Read & Write as CnOperatorId in a configured CnOperator MO.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than one minute

MMEID in an MME MO must be Read Only different from that in any other MME MO.

N/A

N/A

N/A

FIRSTSIGIP in an MME MO must be different from IP in any configured DEVIP MO, and cannot be set to 0.0.0.0. FIRSTSIGIP in an MME MO must be different from FIRSTSIGIP and SECSIGIP in any other MME MO. FIRSTSIGIP in an MME MO must be different from FIRSTSIGIP and SECSIGIP in any X2eNodeB MO.

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an MME MO, FIRSTIPSECPROP NM and FIRSTIKEPEERNM are valid only when FIRSTIPSECFLAG is set to ENABLE. If FIRSTIPSECFLAG Read & Write in an MME MO is set to ENABLE, FIRSTIKEPEERNM in this MO must be the same as PEERNAME in a configured IKEPEER MO.

Yes

NE

Less than one minute

In an MME MO, FIRSTIPSECPROP NM and FIRSTIKEPEERNM are valid only when FIRSTIPSECFLAG is set to ENABLE. If FIRSTIPSECFLAG Read & Write in an MME MO is set to ENABLE, FIRSTIPSECPROP NM in this MO must be the same as PROPNAME in a configured IPSECPROPOSAL MO. If SECSIGIP in an MME MO is valid, that is, it is not set to 0.0.0.0, an SCTP link between the eNodeB and the MME can be set up using SCTP multihoming. If SECSIGIP in an MME MO is valid, it must be different from IP in any configured DEVIP MO. If SECSIGIP in an Read & Write MME MO is valid, it must be different from FIRSTSIGIP in the same MO. If SECSIGIP in an MME MO is valid, it must be different from FIRSTSIGIP or SECSIGIP in any other MME MO. If SECSIGIP in an MME MO is valid, it must be different from FIRSTSIGIP or SECSIGIP in any X2eNodeB MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an MME MO, SECIPSECPROPN M and SECIKEPEERNM are valid only when SECIPSECFLAG is set to ENABLE. If SECIPSECFLAG Read & Write in an MME MO is set to ENABLE, SECIKEPEERNM in this MO must be the same as PEERNAME in a configured IKEPEER MO. In an MME MO, SECIPSECPROPN M and SECIKEPEERNM are valid only when SECIPSECFLAG is set to ENABLE. If SECIPSECFLAG Read & Write in an MME MO is set to ENABLE, SECIPSECPROPN M in this MO must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

CNOPERATORID in an MME MO must be the same Read & Write as CnOperatorId in a configured CnOperator MO.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

S1SERVIPID in an S1ServIP MO must Read Only be different from that in any other S1ServIP MO. S1SERVIP in any S1ServIP MO cannot be set to 0.0.0.0. S1SERVIP in an S1ServIP MO must be the same as IP in a configured DEVIP MO. CN, SRN, and SN in an S1ServIP MO must be the same as those, respectively, in the DEVIP MO associated with the S1SERVIP Read & Write parameter. If S1SERVIP in an S1ServIP MO is on a different network segment from SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an SGW MO and this service IP address in the SGW MO is set to a valid IP address (that is, not 0.0.0.0), a route to SERVIP1, SERVIP2,

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

Yes

NE

Less than one minute

In an S1ServIP MO, this parameter is valid only when IPSECFLAG is set to ENABLE. If IKEIP in an S1ServIP MO is valid, it must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If IKEIP in an S1ServIP MO is valid, CN, SRN, and SN in the same MO must be the same Read & Write as those, respectively, in the DEVIP MO associated with this IKEIP. If IKEIP in an S1ServIP MO is valid and PT in the DEVIP MO associated with the S1SERVIP parameter is not set to LOOPINT, PN in the DEVIP MO associated with IKEIP must be the same as PN in the

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

CNOPERATORID in an S1ServIP MO must be the same Read & Write as CnOperatorId in a configured CnOperator MO. S1ServIP6ID in an S1ServIP6 MO must be different from that in any other S1ServIP6 MO.

Yes

eNodeB

Less than 1 minute

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

S1SERVIP in the S1ServIP MO cannot be set to 0.0.0.0. S1SERVIP in an S1ServIP MO must be the same asIP in a configured DEVIP MO. CN, SRN, and SN in an S1ServIP MO must be the same as those in the DEVIP MO associated with S1SERVIP. If SERVIP1, Read & Write SERVIP2, SERVIP3, or SERVIP4 in an SGW MO is set to a valid IP address (not 0.0.0.0) on a different network segment from S1SERVIP in an S1ServIP MO, a route to SERVIP1, SERVIP2, SERVIP3, or SERVIP4 must have been configured.

Yes

BS

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

This parameter is valid only when IPSECFLAG in the S1ServIP MO is set to ENABLE. This parameter, if valid, cannot be set to 0.0.0.0. It must be the same as IP in a DEVIP MO configured on the local eNodeB, which has PT set to ETH or ETHTRK. If this parameter is valid, CN, SRN, and SN in the S1ServIP Read & Write MO must be the same as those in the DEVIP MO associated with this parameter. If this parameter is valid and PT in the DEVIP MO associated with S1SERVIP is not set to LOOPINT, PN in the DEVIP MO associated with this parameter must be set to the same value as that in the S1ServIP MO.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

The CNOPERATORID parameter in the X2eNodeB MO must be set to the same value as the CnOperatorId parameter in an existing CnOperator MO.

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

S1SIGIPID in an S1SigIP MO must be different from that in any other S1SigIP MO.

Read Only

N/A

N/A

N/A

LOCIP in an S1SigIP MO cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO. CN, SRN, and SN Read & Write in an S1SigIP MO must be the same as those, respectively, in the DEVIP MO associated with LOCIP.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an S1SigIP MO, this parameter is valid only when LOCIPSECFLAG is set to ENABLE. If IKEIP in an S1SigIP MO is valid, it must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If IKEIP in an S1SigIP MO is valid, CN, SRN, and SN in the same MO must be the same Read & Write as those, respectively, in the DEVIP MO associated with this IKEIP. If IKEIP in an S1SigIP MO is valid and PT in the DEVIP MO associated with LOCIP is not set to LOOPINT, PN in the DEVIP MO associated with this IKEIP must be the same as PN in the DEVIP MO In an S1SigIP MO, SECLOCIP must be different from LOCIP. SECLOCIP in an S1SigIP MO must be the same as IP in a configured DEVIP MO. Read & Write CN, SRN, and SN in an S1SigIP MO must be the same as those, respectively, in the DEVIP MO associated with SECLOCIP in the S1SigIP MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an S1SigIP MO, this parameter is valid only when SECLOCIPSECFL AG is set to ENABLE. If SECLOCIKEIP in an S1SigIP MO is valid, must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If SECLOCIKEIP in an S1SigIP MO is valid, CN, SRN, and SN in the same MO Read & Write must be the same as those, respectively, in the DEVIP MO associated with this SECLOCIKEIP. If SECLOCIKEIP in an S1SigIP MO is valid and PT in the DEVIP MO associated with SECLOCIP is not set to LOOPINT, PN in the DEVIP MO associated with this SECLOCIKEIP must be the same

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

The value of the MAXASSOCRETR parameter must be greater than that of Read & Write the MAXPATHRETR parameter.

Yes

NE

Less than one minute

MaxPathRetr must be less than MaxAssocRetr.

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an S1SigIP MO, this parameter is valid only when Read & Write SWITCHBACKFLA G is set to ENABLE.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

CNOPERATORID in an S1SigIP MO must be the same as CnOperatorId in a configured Read & Write CnOperator MO. CNOPERATORID in each S1SigIP MO must have a unique value. S1SIGIP6ID in an S1SigIP6 MO must Read Only be different from that in any other S1SigIP6 MO.

Yes

eNodeB

Less than 1 minute

N/A

N/A

N/A

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

This parameter in an S1SigIP MO cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO. Read & Write CN, SRN, and SN in an S1SigIP MO must be the same as those in the DEVIP MO associated with LOCIP.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than 1 minute

This parameter is valid only when LOCIPSECFLAG in the S1SigIP MO is set to ENABLE. This parameter, if valid, cannot be set to 0.0.0.0. It must be the same as IP in a DEVIP MO configured on the local eNodeB. PT in the DEVIP MO must be set to ETH or ETHTRK. If this parameter is valid, CN, SRN, and Read & Write SN in the S1SigIP MO must be the same as those in the DEVIP MO associated with this parameter. If this parameter is valid and PT in the DEVIP MO associated with LOCIP is not set to LOOPINT, PN in the DEVIP MO associated with IKEIP must be the same as that in the DEVIP associated In an S1SigIP MO, SECLOCIP must be different from LOCIP. SECLOCIP in an S1SigIP MO must be the same as IP in a configured Read & Write DEVIP MO. CN, SRN, and SN in an S1SigIP MO must be the same as those in the DEVIP MO associated with SECLOCIP.

Yes

NE

Less than 1 minute

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

This parameter is valid only when SECIPSECFLAG in the S1SigIP MO is set to ENABLE. This parameter, if not set to 0.0.0.0, must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If this parameter is valid, CN, SRN, and SN in the S1SigIP MO must be the same as those in Read & Write the DEVIP MO associated with this parameter. If this parameter is valid and PT in the DEVIP MO associated with SECLOCIP is not set to LOOPINT, PN in the DEVIP MO associated with SECLOCIKEIP must be the same as that in the DEVIP associated with SECLOCIP.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

MaxAssocRetr must be greater than Read & Write MaxPathRetr.

Yes

NE

Less than 1 minute

MaxPathRetr must be less than MaxAssocRetr.

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

This parameter is valid only when SWITCHBACKFLA Read & Write G in the S1SigIP MO is set to ENABLE.

Yes

NE

Less than 1 minute

The CNOPERATORID parameter in the X2eNodeB MO must be set to the same value as the CnOperatorId parameter in an existing CnOperator MO.

Read & Write

Yes

NE

Less than one minute

SGWID in an SGW MO must be Read Only different from that in any other SGW MO.

N/A

N/A

N/A

SERVIP1 in an SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. In an SGW MO, SERVIP1 must be different from SERVIP2, Read & Write SERVIP3, and SERVIP4. SERVIP1 in an SGW MO must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any other SGW MO.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an SGW MO, SERVIP1IKEPPER NM and SERVIP1IPSECPR OPNM are valid only when SERVIP1IPSECFL AG is set to ENABLE. Read & Write If SERVIP1IPSECFL AG in an SGW MO is set to ENABLE, SERVIP1IKEPPER NM in this MO must be the same as PEERNAME in a configured IKEPEER MO.

Yes

NE

Less than one minute

In an SGW MO, SERVIP1IKEPPER NM and SERVIP1IPSECPR OPNM are valid only when SERVIP1IPSECFL AG is set to ENABLE. If Read & Write SERVIP1IPSECFL AG in an SGW MO is set to ENABLE, SERVIP1IPSECPR OPNM in this MO must be the same as PROPNAME in a configured IPSECPROPOSAL MO. SERVIP2 in an SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. In an SGW MO, SERVIP2 must be different from SERVIP1, Read & Write SERVIP3, and SERVIP4. SERVIP2 in an SGW MO must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any other SGW MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an SGW MO, SERVIP2IKEPPER NM and SERVIP2IPSECPR OPNM are valid only when SERVIP2IPSECFL AG is set to ENABLE. Read & Write If SERVIP2IPSECFL AG in an SGW MO is set to ENABLE, SERVIP2IKEPPER NM in this MO must be the same as PEERNAME in a configured IKEPEER MO. In an SGW MO, SERVIP2IKEPPER NM and SERVIP2IPSECPR OPNM are valid only when SERVIP2IPSECFL AG is set to ENABLE. If Read & Write SERVIP2IPSECFL AG in an SGW MO is set to ENABLE, SERVIP2IPSECPR OPNM in this MO must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

SERVIP3 in an SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. In an SGW MO, SERVIP3 must be different from SERVIP1, Read & Write SERVIP2, and SERVIP4. SERVIP3 in an SGW MO must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any other SGW MO.

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an MME MO, SERVIP3IKEPPER NM and SERVIP3IPSECPR OPNM are valid only when SERVIP3IPSECFL AG is set to ENABLE. Read & Write If SERVIP3IPSECFL AG in an SGW MO is set to ENABLE, SERVIP3IKEPPER NM in this MO must be the same as PEERNAME in a configured IKEPEER MO.

Yes

NE

Less than one minute

In an SGW MO, SERVIP3IKEPPER NM and SERVIP3IPSECPR OPNM are valid only when SERVIP3IPSECFL AG is set to ENABLE. If Read & Write SERVIP3IPSECFL AG in an SGW MO is set to ENABLE, SERVIP3IPSECPR OPNM in this MO must be the same as PROPNAME in a configured IPSECPROPOSAL MO. SERVIP4 in an SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. In an SGW MO, SERVIP4 must be different from SERVIP1, Read & Write SERVIP2, and SERVIP3. SERVIP4 in an SGW MO must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any other SGW MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

In an SGW MO, SERVIP4IKEPPER NM and SERVIP4IPSECPR OPNM are valid only when SERVIP4IPSECFL AG is set to ENABLE. Read & Write If SERVIP4IPSECFL AG in an SGW MO is set to ENABLE, SERVIP4IKEPPER NM in this MO must be the same as PEERNAME in a configured IKEPEER MO. In an SGW MO, SERVIP4IKEPPER NM and SERVIP4IPSECPR OPNM are valid only when SERVIP4IPSECFL AG is set to ENABLE. If Read & Write SERVIP4IPSECFL AG in an SGW MO is set to ENABLE, SERVIP4IPSECPR OPNM in this MO must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

CNOPERATORID in an SGW MO must be the same Read & Write as CnOperatorId in a configured CnOperator MO.

Yes

NE

Less than one minute

SGWID in an SGW6 MO must be different from that in Read Only any other SGW6 MO. SERVIP1 in the SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. SERVIP1 must be set to a different value from those of SERVIP2, SERVIP3, and Read & Write SERVIP4 in the same SGW MO. SERVIP1 must be set to a different value from those of SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any configured SGW MO.

N/A

N/A

N/A

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

SERVIP1IKEPPER NM and SERVIP1IPSECPR OPNM are valid only when SERVIP1IPSECFL AG is set to ENABLE. If Read & Write SERVIP1IPSECFL AG in the SGW MO is set to ENABLE, SERVIP1IKEPPER NM must be the same as PEERNAME in a configured IKEPEER MO. SERVIP1IKEPPER NM and SERVIP1IPSECPR OPNM are valid only when SERVIP1IPSECFL AG is set to ENABLE. If SERVIP1IPSECFL Read & Write AG in the SGW MO is set to ENABLE, SERVIP1IPSECPR OPNM must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than one minute

Yes

NE

Less than one minute

SERVIP2 in the SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. SERVIP2 must be set to a different value from those of SERVIP1, SERVIP3, and Read & Write SERVIP4 in the same SGW MO. SERVIP1 must be set to a different value from those of SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any configured SGW MO.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

SERVIP2IKEPPER NM and SERVIP2IPSECPR OPNM are valid only when SERVIP2IPSECFL AG is set to ENABLE. If Read & Write SERVIP2IPSECFL AG in the SGW MO is set to ENABLE, SERVIP2IKEPPER NM must be the same as PEERNAME in a configured IKEPEER MO. SERVIP2IKEPPER NM and SERVIP2IPSECPR OPNM are valid only when SERVIP2IPSECFL AG is set to ENABLE. If SERVIP2IPSECFL Read & Write AG in the SGW MO is set to ENABLE, SERVIP2IPSECPR OPNM must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than 1 minute

Yes

NE

Less than one minute

SERVIP3 in the SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. SERVIP3 must be set to a different value from those of SERVIP1, SERVIP2, and Read & Write SERVIP4 in the same SGW MO. SERVIP3 must be set to a different value from those of SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any configured SGW MO.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

SERVIP3IKEPPER NM and SERVIP3IPSECPR OPNM are valid only when SERVIP3IPSECFL AG is set to ENABLE. If Read & Write SERVIP3IPSECFL AG in the SGW MO is set to ENABLE, SERVIP3IKEPPER NM must be the same as PEERNAME in a configured IKEPEER MO. SERVIP3IKEPPER NM and SERVIP3IPSECPR OPNM are valid only when SERVIP3IPSECFL AG is set to ENABLE. If SERVIP3IPSECFL Read & Write AG in the SGW MO is set to ENABLE, SERVIP3IPSECPR OPNM must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than 1 minute

Yes

NE

Less than one minute

SERVIP4 in the SGW MO cannot be set to 0.0.0.0, and must be different from IP in any configured DEVIP MO. SERVIP4 must be set to a different value from those of SERVIP1, SERVIP2, and Read & Write SERVIP3 in the same SGW MO. SERVIP4 must be set to a different value from those of SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any configured SGW MO.

Yes

NE

Less than 1 minute

None

Read & Write

Yes

NE

Less than 1 minute

SERVIP4IKEPPER NM and SERVIP4IPSECPR OPNM are valid only when SERVIP4IPSECFL AG is set to ENABLE. If Read & Write SERVIP4IKEPPER NM in the SGW MO is set to ENABLE, SERVIP4IKEPPER NM must be the same as PEERNAME in a configured IKEPEER MO. SERVIP4IKEPPER NM and SERVIP4IPSECPR OPNM are valid only when SERVIP4IPSECFL AG is set to ENABLE. If SERVIP4IKEPPER Read & Write NM in the SGW MO is set to ENABLE, SERVIP4IPSECPR OPNM must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

Yes

NE

Less than 1 minute

Yes

NE

Less than one minute

None

Read & Write

Yes

NE

Less than one minute

CNOPERATORID in an SGW MO must be the same Read & Write as CnOperatorId in a configured CnOperator MO.

Yes

NE

Less than 1 minute

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

X2SERVIPID in an X2ServIP MO must Read Only be different from that in any other X2ServIP MO. X2SERVIP in any X2ServIP MO cannot be set to 0.0.0.0. CN, SRN, and SN in an X2ServIP MO must be the same as those, respectively, in the DEVIP MO associated with X2SERVIP. X2SERVIP in an X2ServIP MO must be the same as IP in a configured DEVIP MO. Read & Write If X2SERVIP in an X2ServIP MO is on a different network segment from SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO and this service IP address in the X2eNodeB MO is set to a valid IP address (that is, not 0.0.0.0), a route to SERVIP1, SERVIP2,

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2ServIP MO, this parameter is valid only when Read & Write IPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2ServIP MO, this parameter is valid only when IPSECFLAG is set to ENABLE. If IKEIP in an X2ServIP MO is valid, it cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If IKEIP in an X2ServIP MO is valid, CN, SRN, and Read & Write SN in the same MO must be the same as those, respectively, in the DEVIP MO associated with this IKEIP. If IKEIP in an X2ServIP MO is valid and PT in the DEVIP MO associated with the S1SERVIP parameter is not set to LOOPINT, PN in the DEVIP MO associated with In an X2ServIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to Read & Write ENABLE. IKEPEERNM, if valid, must be the same as PEERNAME in a configured IKEPEER MO.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2ServIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to ENABLE. Read & Write If this parameter in an X2ServIP MO is valid, it must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

CNOPERATORID in an X2ServIP MO must be the same Read & Write as CnOperatorId in a configured CnOperator MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

X2SIGIPID in an X2SigIP MO must be different from that in any other X2SigIP MO.

Read Only

N/A

N/A

N/A

LOCIP in an X2SigIP MO cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO. CN, SRN, and SN Read & Write in an X2SigIP MO must be the same as those, respectively, in the DEVIP MO associated with LOCIP.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when Read & Write IPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when IPSECFLAG is set to ENABLE. If IKEIP in an X2SigIP MO is valid, it cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If IKEIP in an X2SigIP MO is valid, CN, SRN, and Read & Write SN in the same MO must be the same as those, respectively, in the DEVIP MO associated with this IKEIP. If IKEIP in an X2SigIP MO is valid and PT in the DEVIP MO associated with LOCIP is not set to LOOPINT, PN in the DEVIP MO associated with this IKEIP must be the

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to Read & Write ENABLE. IKEPEERNM, if valid, must be the same as PEERNAME in a configured IKEPEER MO. In an X2SigIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to ENABLE. Read & Write If this parameter in an X2SigIP MO is valid, it must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

If SECLOCIP in an X2SigIP MO is valid, that is, it is not set to 0.0.0.0, an SCTP link between the neighboring eNodeB and the local eNodeB can be set up using SCTP multihoming. This parameter, if valid, must be the same as IP in a Read & Write configured DEVIP MO. If SECLOCIP in an X2SigIP MO is valid, CN, SRN, and SN in the same MO must be the same as those, respectively, in the DEVIP MO associated with this SECLOCIP.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when Read & Write SECIPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when SECLOCIPSECFL AG is set to ENABLE. If SECLOCIKEIP in an X2SigIP MO is valid, it cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If SECLOCIKEIP in an X2SigIP MO is Read & Write valid, CN, SRN, and SN in the same MO must be the same as those, respectively, in the DEVIP MO associated with this IKEIP. If SECLOCIKEIP in an X2SigIP MO is valid and PT in the DEVIP MO associated with SECLOCIP is not set to LOOPINT, PN in the DEVIP MO associated with

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, SECIKEPEERNM and SECIPSECPROPN M are valid only when SECIPSECFLAG and Read & Write SECSEGWFLAG are both set to ENABLE. SECIKEPEERNM, if valid, must be the same as PEERNAME in a configured IKEPEER MO. In an X2SigIP MO, SECIKEPEERNM and SECIPSECPROPN M are valid only when SECIPSECFLAG and SECSEGWFLAG Read & Write are both set to ENABLE. If this parameter in an X2SigIP MO is valid, it must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, RTOMAX must be Read & Write greater than RTOMIN.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

MaxAssocRetr must be greater than Read & Write MaxPathRetr.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, MaxPathRetr must Read & Write be smaller than MaxAssocRetr.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

SWITCHBACKHBN UM is valid only when Read & Write SWITCHBACKFLA G is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

SWITCHBACKHBN UM is valid only when Read & Write SWITCHBACKFLA G is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

CNOPERATORID in an X2SigIP MO must be the same as CnOperatorId in a configured Read & Write CnOperator MO. CNOPERATORID in each X2SigIP MO must have a unique value. X2ENODEBID in an X2eNodeB MO must be different Read Only from that in any other X2eNodeB MO. FIRSTSIGIP in an X2eNodeB MO cannot be set to 0.0.0.0 and must be a valid IP address that is different from IP in any configured DEVIP MO. FIRSTSIGIP in an X2eNodeB MO must be different Read & Write from FIRSTSIGIP and SECSIGIP in any other X2eNodeB MO. FIRSTSIGIP in an X2eNodeB MO must be different from FIRSTSIGIP and SECSIGIP in any configured MME MO.

Yes

eNodeB

Less than 1 minute

N/A

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write FIRSTSEGWFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, FIRSTIKEIP is valid only when FIRSTIPSECFLAG is set to ENABLE and FIRSTSEGWFLAG Read & Write is set to DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 or IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

If SECSIGIP in an X2eNodeB MO is valid, that is, it is not set to 0.0.0.0, an SCTP link between the neighboring eNodeB and the local eNodeB can be set up using SCTP multihoming. If SECLOCIP in an X2eNodeB MO is valid, it must be different from IP in any configured DEVIP MO. In an X2eNodeB Read & Write MO, SECSIGIP, if valid, must be different from FIRSTSIGIP. In an X2eNodeB MO, SECLOCIP, if valid, must be different from FIRSTSIGIP or SECSIGIP. If SECLOCIP in an X2eNodeB MO is valid, it must be different from FIRSTSIGIP or SECSIGIP in any configured MME

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SECIPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SECIPSECFLAG is set to ENABLE and SECSEGWFLAG is Read & Write set to DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 or IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4 is valid if it is not 0.0.0.0. In this situation, it must be set to a valid IP address. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from SERVIP1, SERVIP2,

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP1IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP1IPSECFL AG is set to ENABLE and SERVIP1SEGWFL Read & Write AG is set to DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 and must be different from IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4 is valid if it is not 0.0.0.0. In this situation, it must be set to a valid IP address. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from SERVIP1, SERVIP2,

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP2IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP2IPSECFL AG is set to ENABLE and SERVIP2SEGWFL Read & Write AG is set to DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 and must be different from IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4 is valid if it is not 0.0.0.0. In this situation, it must be set to a valid IP address. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from SERVIP1, SERVIP2,

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP3IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP3IPSECFL AG is set to ENABLE and SERVIP3SEGWFL AG is set to Read & Write DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 and must be set to an IP address different from IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4 is valid if it is not 0.0.0.0. In this situation, it must be set to a valid IP address. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. If SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO is valid, it must be different from SERVIP1, SERVIP2,

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP4IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP4IPSECFL AG is set to ENABLE and SERVIP4SEGWFL AG is set to Read & Write DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 and must be set to an IP address different from IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None CNOPERATORID in an X2eNodeB MO must be the same as CnOperatorId in a configured CnOperator MO.

Read & Write

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

X2ServIP6ID in an X2ServIP6 MO must be different from that in any other X2ServIP6 MO.

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

X2SERVIP in an X2ServIP MO cannot be set to 0.0.0.0. X2SERVIP in an X2ServIP MO must be the same as IP in a configured DEVIP MO. CN, SRN, and SN Read & Write in an X2ServIP MO must be the same as those respectively in the DEVIP MO associated with X2SERVIP in the same X2ServIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write IPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2ServIP MO, this parameter is valid only when IPSECFLAG is set to ENABLE. This parameter, if not set to 0.0.0.0, must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If this parameter is valid, CN, SRN, and SN in the X2SigIP MO must be the same as those in Read & Write the DEVIP MO associated with this parameter. If this parameter is valid and PT in the DEVIP MO associated with X2SERVIP is not set to LOOPINT, PN in the DEVIP MO associated with IKEIP must be the same as PN in the S1ServIP MO associated with LOCIP. In an X2ServIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to Read & Write ENABLE. IKEPEERNM, if valid, must be the same as PEERNAME in a configured IKEPEER MO.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2ServIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to ENABLE. Read & Write This parameter in an X2ServIP MO, if valid, must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

The CNOPERATORID parameter in the X2eNodeB MO must be set to the same value as the CnOperatorId parameter in an existing CnOperator MO.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

X2SIGIP6ID in an X2SigIP6 MO must Read Only be different from that in any other X2SigIP6 MO.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter in an X2SigIP MO cannot be set to 0.0.0.0 and must be the same as IP in a configured DEVIP MO. Read & Write CN, SRN, and SN in the X2SigIP MO must be the same as those in the DEVIP MO associated with LOCIP.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when Read & Write IPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when LOCIPSECFLAG is set to ENABLE. This parameter, if not set to 0.0.0.0, must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If this parameter is valid, CN, SRN, and SN in the X2SigIP MO must be the Read & Write same as those in the DEVIP MO associated with this parameter. If this parameter is valid and PT in the DEVIP MO associated with LOCIP is not set to LOOPINT, PN in the DEVIP MO associated with IKEIP must be the same as PN in the DEVIP associated with LOCIP. In an X2SigIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to Read & Write ENABLE. IKEPEERNM, if valid, must be the same as PEERNAME in a configured IKEPEER.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, IKEPEERNM and IPSECPROPNM are valid only when IPSECFLAG and SEGWFLAG are both set to ENABLE. Read & Write This parameter in an X2SigIP MO, if valid, must be the same as PROPNAME in a configured IPSECPROPOSAL MO. This parameter in the X2SigIP MO is valid if it is not set to 0.0.0.0. This enables the local eNodeB to set up an SCTP link based on SCTP multihoming with the peer eNodeB. This parameter, if valid, must be the same as IP in a Read & Write configured DEVIP MO. If SECLOCIP in an X2SigIP MO is valid, CN, SRN, and SN in the X2SigIP MO must be the same as those in the DEVIP MO associated with SECLOCIP, respectively.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when Read & Write SECIPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, this parameter is valid only when SECIPSECFLAG is set to ENABLE. This parameter, if not set to 0.0.0.0, must be the same as IP in a configured DEVIP MO with PT set to ETH or ETHTRK. If this parameter is valid, CN, SRN, and SN in the X2SigIP MO must be the same as those in Read & Write the DEVIP MO associated with this parameter. If this parameter is valid and PT in the DEVIP MO associated with SECLOCIP is not set to LOOPINT, PN in the DEVIP MO associated with SECLOCIKEIP must be the same as PN in the DEVIP associated with SECLOCIP. In an X2SigIP MO, SECIKEPEERNM and SECIPSECPROPN M are valid only when SECIPSECFLAG and Read & Write SECSEGWFLAG are both set to ENABLE. SECIKEPEERNM, if valid, must be the same as PEERNAME in a configured IKEPEER MO.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2SigIP MO, SECIKEPEERNM and SECIPSECPROPN M are valid only when SECIPSECFLAG and SECSEGWFLAG Read & Write are both set to ENABLE. This parameter in an X2SigIP MO, if valid, must be the same as PROPNAME in a configured IPSECPROPOSAL MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the X2SigIP MO, the value of the RtoMax parameter Read & Write must be larger than that of the RtoMin parameter.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

MaxAssocRetr must be greater than Read & Write MaxPathRetr.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

SWITCHBACKHBN UM is valid only when Read & Write SWITCHBACKFLA G is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

The CNOPERATORID parameter in the X2eNodeB MO must be set to the same value as the CnOperatorId parameter in an existing CnOperator MO.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

X2ENODEBID in an X2eNodeB6 MO must be different Read Only from that in any other X2eNodeB6 MO.

N/A

N/A

N/A

FIRSTSIGIP in an X2eNodeB MO must be a valid IP address (not 0.0.0.0) different from IP in any configured DEVIP MO. FIRSTSIGIP in an X2eNodeB MO must be different Read & Write from FIRSTSIGIP or SECSIGIP in any other X2eNodeB MOs. FIRSTSIGIP in an X2eNodeB MO must be different from FIRSTSIGIP or SECSIGIP in any MME MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB6 MO, this parameter is valid only when Read & Write FIRSTSEGWFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, FIRSTIKEIP is valid only when FIRSTIPSECFLAG is set to ENABLE and FIRSTSEGWFLAG Read & Write is set to DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 or IP in any configured DEVIP MOs.

No (And no impact on the UE in idle mode)

N/A

N/A

SECSIGIP in an X2eNodeB MO is valid if it is not set to 0.0.0.0. This enables the peer eNodeB to set up an SCTP link based on SCTP multihoming with the local eNodeB. SECSIGIP must be different from IP in any configured DEVIP MO if SECLOCIP in the same X2eNodeB MO is valid. Read & Write SECSIGIP, if valid, must be different from FIRSTSIGIP in the same X2eNodeB MO. In an X2eNodeB MO, a valid SECLOCIP must be different from FIRSTSIGIP or SECSIGIP. SECSIGIP in an X2eNodeB MO must be different from FIRSTSIGIP or SECSIGIP in any MME MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB6 MO, this parameter is valid only when Read & Write SECIPSECFLAG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In the X2eNodeB MO, this parameter is valid when SECIPSECFLAG is set to ENABLE and SECSEGWFLAG is Read & Write set to DISABLE. This parameter, if valid, cannot be set to 0.0.0.0 or IP in any configured DEVIP MOs.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if not set to 0.0.0.0, must be a valid IP address. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if valid, must be different from IP in any configured DEVIP MO. In an X2eNodeB Read & Write MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO, if valid, must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP1IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP1IPSECFL AG is set to ENABLE and SERVIP1SEGWFL Read & Write AG is set to DISABLE. This parameter must be a valid IP address different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if not set to 0.0.0.0, must be a valid IP address. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if valid, must be different from IP in any configured DEVIP MO. In an X2eNodeB Read & Write MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO, if valid, must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP2IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP2IPSECFL AG is set to ENABLE and SERVIP2SEGWFL AG is set to Read & Write DISABLE. This parameter must be set to a valid IP address (not 0.0.0.0) different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if not set to 0.0.0.0, must be a valid IP address. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if valid, must be different from IP in any configured DEVIP MO. In an X2eNodeB Read & Write MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO, if valid, must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP3IPSECFL AG is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP3IPSECFL AG is set to ENABLE and SERVIP3SEGWFL AG is set to Read & Write DISABLE. This parameter must be set to a valid IP address (not 0.0.0.0) different from IP in any configured DEVIP MO. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if not set to 0.0.0.0, must be a valid IP address. In an X2eNodeB MO, SERVIP1, SERVIP2, SERVIP3, or SERVIP4, if valid, must be different from IP in any configured DEVIP MO. In an X2eNodeB Read & Write MO, SERVIP1, SERVIP2, SERVIP3, and SERVIP4, if valid, must be different from each other. SERVIP1, SERVIP2, SERVIP3, or SERVIP4 in an X2eNodeB MO, if valid, must be different from SERVIP1, SERVIP2, SERVIP3, and SERVIP4 in any

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when Read & Write SERVIP4IKEPPER NM is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

In an X2eNodeB MO, this parameter is valid only when SERVIP4IKEPPER NM is set to ENABLE and SERVIP4SEGWFL AG is set to Read & Write DISABLE. This parameter must be set to a valid IP address (not 0.0.0.0) different from IP in any configured DEVIP MO.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

CNOPERATORID in an X2eNodeB6 MO must be the same as CnOperatorId in a configured CnOperator MO.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

URL in a CA MO must begin with http or https, the IP address must be a Read & Write valid IP address, and the port number must range from 1 to 65535.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

USERADDINFO in a CERTREQ MO must contain only printable ASCII Read & Write characters (the ASCII value within the range of 32 to 127).

No (And no impact on the UE in idle mode)

N/A

N/A

COUNTRY in a CERTREQ MO must contain only the following printable ASCII characters: A~Z a~z Read & Write ' ( ) + , - . / 0~9 : = ?. The string length of COUNTRY in a CERTREQ MO must be 0 or 2. ORG in a CERTREQ MO must contain only printable ASCII characters (the ASCII value within the range of 32 to 127). ORGUNIT in a CERTREQ MO must contain only printable ASCII characters (the ASCII value within the range of 32 to 127).

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

STATEPROVINCE NAME in a CERTREQ MO must contain only Read & Write printable ASCII characters (the ASCII value within the range of 32 to 127). LOCALITY in a CERTREQ MO must contain only printable ASCII characters (the ASCII value within the range of 32 to 127).

No (And no impact on the UE in idle mode)

N/A

N/A

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

LOCALNAME in a CERTREQ MO must contain only printable ASCII characters (the ASCII value within the range of 32 to 127).

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

LOCALIP in a CERTREQ MO must be a valid IP address of class A, B, or C. In addition, Read & Write it cannot be set to the reserved IP addresses 127.x.x.x or 0.x.x.x but can be set to 0.0.0.0.

No (And no impact on the UE in idle mode)

N/A

N/A

The CERTMK MO with APPCERT set to appcert.pem defines a certificate configured on a BS before delivery. There is only one such MO on a BS and this MO cannot be added or removed. APPCERT in a Read Only CERTMK MO can contain only ASCII characters. The name must not contain spaces or the following characters: \ / : * ? " < > |. APPCERT in a CERTMK MO is case insensitive. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

On a BS, there is only one activated device certificate for Read Only each application type.

N/A

N/A

N/A

APPCERT in an APPCERT MO can contain only ASCII characters. The Read & Write name must not contain spaces or the following characters: \ / : * ? " < > |.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

CERTNAME in a CROSSCERT MO can contain only ASCII characters. The name must not contain spaces or Read Only the following characters: \ / : * ? " < > |. CERTNAME in a CROSSCERT MO is case insensitive.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

On a BS, there is only one TRUSTCERT MO with CERTNAME set to caroot.pem. CERTNAME in a TRUSTCERT MO can contain only Read Only ASCII characters. The name must not contain spaces or the following characters: \ / : * ? " < > |. CERTNAME in a TRUSTCERT MO is case insensitive. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

CERTNAME in a CRL MO can contain only ASCII characters. The name must not contain spaces or Read Only the following characters: \ / : * ? " < > |. CERTNAME in a CRL MO is case insensitive.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

IP in a CRLTSK MO must be set to a valid IP address of class A, B, or C. In Read Only addition, It cannot be set to 127.x.x.x or 0.x.x.x (including 0.0.0.0).

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when CRLGETMETHOD Read Only in the same CRLTSK MO is set to LDAP. Each CRLTSK MO must have a unique FILENAME and FILENAME in a CRLTSK MO is case insensitive. FILENAME in a Read Only CRLTSK MO can contain only ASCII characters. The name must not contain spaces or the following characters: \ / : * ? " < > |.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when CRLGETMETHOD Read Only in the same CRLTSK MO is set to LDAP. None Read & Write

N/A

N/A

N/A

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

In a CERTCHKTSK MO, PERIOD must Read & Write be smaller than ALMRNG.

N/A

N/A

In a CERTCHKTSK MO, PERIOD must Read & Write be smaller than ALMRNG.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when ACLID in the ACLRULE MO is within the range of 3000 to 3999.

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

In an ACLRULE MO, MFRG and SMPT must not be both set to YES. Read Only In the ACLRULE MO, this parameter is valid only when PT is set to TCP, UDP, or SCTP.

N/A

N/A

N/A

In the ACLRULE MO, this parameter is valid only when Read Only SMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE MO, if SOP is set to OP_RANGE, SPT1 must be smaller than or equal to Read Only SPT2. In the ACLRULE MO, this parameter is valid only when SMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE MO, if SOP is set to OP_RANGE, SPT1 must be smaller than or equal to SPT2. Read Only In the ACLRULE MO, this parameter is valid only when SMPT is set to YES and SOP is set to OP_RANGE.

N/A

N/A

N/A

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

In an ACLRULE MO, MFRG and DMPT must not be both set to YES. Read Only In the ACLRULE MO, this parameter is valid only when PT is set to TCP, UDP, or SCTP.

N/A

N/A

N/A

In the ACLRULE MO, this parameter is valid only when Read Only DMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE MO, if DOP is set to OP_RANGE, DPT1 must be smaller than or equal to Read Only DPT2. In the ACLRULE MO, this parameter is valid only when DMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE MO, if DOP is set to OP_RANGE, DPT1 must be smaller than or equal to Read Only DPT2. In the ACLRULE MO, this parameter is valid only when DOP is set to OP_RANGE.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the ACLRULE MO, this parameter is valid only when Read Only MDSCP is set to YES. In an ACLRULE MO, MFRG and SMPT must not be both set to YES. In an ACLRULE MO, MFRG and DMPT must not be Read Only both set to YES. In the ACLRULE MO, this parameter is valid only when PT is set to a valid value.

N/A

N/A

N/A

N/A

N/A

N/A

This parameter is valid only when ACLID in the ACLRULE MO is within the range of 4000 to 4999.

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

If ACLID ranges from 4000 to 4999 and VLANIDOP is set to OP_RANGE, Read & Write VLANID1 must be smaller than VLANID2.

Yes

BS

Services are interrupted until the parameter is correctly set.

If ACLID ranges from 4000 to 4999 and VLANIDOP is set to OP_RANGE, Read & Write VLANID1 must be smaller than VLANID2.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

In an ACLRULE6 MO, this parameter is valid when PT is Read Only set to TCP, UDP, or SCTP.

N/A

N/A

N/A

In an ACLRULE6 MO, this parameter is valid when PT is Read Only set to TCP, UDP, or SCTP and SMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE6 MO, if SOP is set to OP_RANGE, SPT1 must be smaller than SPT2. Read Only In an ACLRULE6 MO, this parameter is valid when PT is set to TCP, UDP, or SCTP and SMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE6 MO, if SOP is set to OP_RANGE, SPT1 must be smaller than SPT2. In an ACLRULE6 Read Only MO, this parameter is valid when PT is set to TCP, UDP, or SCTP, SMPT is set to YES, and SOP is set to OP_RANGE.

N/A

N/A

N/A

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

In an ACLRULE6 MO, this parameter is valid when PT is Read Only set to TCP, UDP, or SCTP.

N/A

N/A

N/A

In an ACLRULE6 MO, this parameter is valid when PT is Read Only set to TCP, UDP, or SCTP and DMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE6 MO, if DOP is set to OP_RANGE, DPT1 must be smaller than DPT2, respectively. Read Only In an ACLRULE6 MO, this parameter is valid when PT is set to TCP, UDP, or SCTP and DMPT is set to YES.

N/A

N/A

N/A

In an ACLRULE6 MO, if DOP is set to OP_RANGE, DPT1 must be smaller than DPT2, respectively. Read Only In an ACLRULE6 MO, this parameter is valid when PT is set to TCP, UDP, or SCTP, DMPT is set to YES, and DOP is set to OP_RANGE.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an ACLRULE6 MO, this parameter is valid when Read Only MDSCP is set to YES.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

SRCIP in a BFDSESSION MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to Read & Write 0.x.x.x or 127.x.x.x (including 0.0.0.0). SRCIP must be different from DSTIP in a BFDSESSION MO.

Yes

BS

Less than 1 minute

DSTIP in a BFDSESSION MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to Read & Write 0.x.x.x or 127.x.x.x (including 0.0.0.0). SRCIP must be different from DSTIP in a BFDSESSION MO.

Yes

BS

Less than 1 minute

In the BFDSESSION MO, if SRCIP is set to a Read & Write logical IP address, HT cannot be set to SINGLE_HOP.

Yes

BS

Less than 1 minute

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

N/A

N/A

In the CFMBNDIP MO, the total length of MANAME and Read Only MDNAME cannot exceed 44 bytes. MANAME in a CFMBNDIP MO can contain only ASCII characters. The name cannot be null characters or contain the following Read Only characters: ', ", !, ?, <, >, and \. In the CFMBNDIP MO, the total length of MANAME and MDNAME cannot exceed 44 bytes.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the CFMMA MO, the total length of MANAME and Read Only MDNAME cannot exceed 44 bytes.

N/A

N/A

N/A

MANAME in a CFMMA MO can contain only ASCII characters. The name cannot be null characters or contain the following Read Only characters: ', ", !, ?, <, >, and \. In the CFMMA MO, the total length of MANAME and MDNAME cannot exceed 44 bytes. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the CFMMA MO, this parameter is valid only when Read Only BNDVLAN is set to YES. In the CFMMA MO, this parameter is valid only when Read & Write BNDVLAN is set to YES.

N/A

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

MDNAME in a CFMMD MO can contain only ASCII characters. The name cannot be null Read Only characters or contain the following characters: ', ", !, ?, <, >, and \.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the CFMMEP MO, the total length of MANAME and Read Only MDNAME cannot exceed 44 bytes. In the CFMMEP MO, the total length of MANAME and MDNAME cannot exceed 44 bytes. MANAME in a CFMMEP MO can contain only ASCII Read Only characters. The name cannot be null characters or contain the following characters: ', ", !, ?, <, >, and \.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a CFMMEP MO, this parameter must be set to ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In a CFMMEP MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

In the CFMMEP MO, if PT is set to ETH and SBT is set to ETH_COVERBOAR D, the value range of this parameter is from 0 to 5. In the CFMMEP MO, if PT is set to ETH and SBT is set to BASE_BOARD, this parameter can be set to 0 or 1. Read Only In the CFMMEP MO, if PT is set to ETHTRK and SBT is set to BASE_BOARD, this parameter can be set to 0 or 1. In the CFMMEP MO, if PT is set to ETHTRK and SBT is set to ETH_COVERBOAR D, the value range of this parameter is from 0 to 2.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the CFMRMEP MO, the total length of MANAME and Read Only MDNAME cannot exceed 44 bytes.

N/A

N/A

N/A

MANAME in a CFMRMEP MO can contain only ASCII characters. The name cannot be null characters or contain the following Read Only characters: ', ", !, ?, <, >, and \. In the CFMRMEP MO, the total length of MANAME and MDNAME cannot exceed 44 bytes. RMEPID in the CFMRMEP MO Read Only must be unique in the CFM MA.

N/A

N/A

N/A

N/A

N/A

N/A

MAC in the CFMRMEP MO is expressed in the format of XXXXXXXX-XXXX. It cannot be set to the broadcast MAC address (FFFFFFFF-FFFF). It also Read Only cannot be set to a multicast MAC address, which is typically 0100-5EXXXXXX or one MAC address in the range of 80XXXXXX-XXXX to FFXX-XXXX-XXXX.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a DBGSVR MO, if SERVICETYPE is set to TCP, this parameter can be set to any of the following values: 22, 23, 80, 443, 1110, 1120, 2700, 4443, 6000, 6001, 6006, 6007 and 30023. Read Only In a DBGSVR MO, if SERVICETYPE is set to UDP, this parameter can be set to any of the following values: 67, 68, 319, 320, 500, 3784, 4500, 4784, 17185, 33003, and 45300.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a DEVIP MO, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D if SN is set to a value within the Read Only range of 0 to 5. In a DEVIP MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7. In a DEVIP MO, this parameter can be set to PPP, MPGRP, ETH, ETHTRK, or LOOPINT if SBT is set to BASE_BOARD. In a DEVIP MO, this parameter can be set to ETH, ETHTRK, or Read Only LOOPINT if SBT is set to ETH_COVERBOAR D. In a DEVIP MO, this parameter can be set to PPP, MPGRP, or LOOPINT if SBT is set to E1_COVERBOARD .

N/A

N/A

N/A

N/A

N/A

N/A

In a DEVIP MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD and PT is set to ETH. In a DEVIP MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD and PT is set to ETHTRK. In a DEVIP MO, this parameter can be set to 0 or 15 if PT is set to PPP. Read Only In a DEVIP MO, this parameter can be set to 0 or 3 if PT is set to MPGRP. In a DEVIP MO, this parameter can be set to a value within the range of 0 to 5 if SBT is set to ETH_COVERBOAR D and PT is set to ETH. In a DEVIP MO, this parameter can be set to a value within the range of 0 to 2 if SBT is set to IP in the DEVIP MO must be set to a valid IP address of Class A, B, or C. In addition, it cannot be 127.x.x.x or 0.x.x.x. In the logical Read Only operation result of IP and MASK in a DEVIP MO, neither the network ID nor host ID can be all 0s or 1s after being converted into a binary value.

N/A

N/A

N/A

N/A

N/A

N/A

In a DEVIP MO, if PT is not set to LOOPINT, MASK cannot be set to all 1s. In the binary value into which MASK in the DEVIP MO is converted, 0 is not allowed to precede Read & Write 1. In the logical operation result of IP and MASK in a DEVIP MO, neither the network ID nor host ID can be all 0s or 1s after being converted into a binary value.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a DEVIP6 MO, if IPV6 is set to the local address of a Read Only link, PFXLEN must be greater than or equal to 10.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

DHCPSVRIP in a DHCPSVRIP MO must be a valid IP address of class A, Read Only B, or C. In addition, it cannot be 0.x.x.x or 127.x.x.x.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, the value range of this parameter is from 0 to 63 if PRIRULE is set to DSCP. In the DIFPRI MO, the value range of this parameter is from 0 to 7 if PRIRULE is set to IPPRECEDENCE.

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

In a DIFPRI MO, OMLOWPRI must be smaller than or equal to OMHIGHPRI. In the DIFPRI MO, if PRIRULE is set to DSCP, the value Read & Write range of this parameter is from 0 to 63. In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

In a DIFPRI MO, OMLOWPRI must be smaller than or equal to OMHIGHPRI. In the DIFPRI MO, if PRIRULE is set to DSCP, the value Read & Write range of this parameter is from 0 to 63. In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the DIFPRI MO, if PRIRULE is set to DSCP, the value range of this parameter is from 0 to 63. Read & Write In the DIFPRI MO, if PRIRULE is set to IPPRECEDENCE, the value range of this parameter is from 0 to 7.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the DOT1X MO, if SBT is set to BASE_BOARD, this parameter can be set to 0 or 1. In the DOT1X MO, Read Only if SBT is set to ETH_COVERBOAR D, the value range of this parameter is from 0 to 5.

N/A

N/A

N/A

In a DOT1X MO, AM must be set to EAP-TLS if ACT is set to ACTIVE.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the E1T1 MO, this parameter is valid only when PS Read Only is set to SINGLEPORT.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the E1T1 MO, this parameter is Read & Write valid only when PS is set to ALLPORT.

Yes

BS

Less than 1 minute

In an E1T1 MO, if PS is set to ALLPORT and WORKMODE is set to E1_UNBA or E1_BA, FRAME can be set to E1_DOUBLE_FRA ME or E1_CRC4_MULTI_ FRAME. In an E1T1 MO, if PS and WORKMODE are set to ALLPORT and T1, respectively, Read & Write FRAME can be set to T1_SUPER_FRAM E or T1_EXTENDED_S UPER_FRAME. If WORKMODE in an all-port E1T1 MO is set to E1_UNBA or E1_BA, FRAME can be set to E1_DOUBLE_FRA ME or E1_CRC4_MULTI_ FRAME in each single-port E1T1 MO. If

Yes

BS

Less than 1 minute

In an E1T1 MO, if PS is set to ALLPORT and WORKMODE is set to E1_UNBA or E1_BA, LNCODE can be set to AMI or HDB3. In an E1T1 MO, if PS and WORKMODE are set to ALLPORT and T1, respectively, LNCODE can be set to AMI or B8ZS. If WORKMODE in Read & Write an all-port E1T1 MO is set to E1_UNBA or E1_BA, LNCODE can be set to AMI or HDB3 in each single-port E1T1 MO. If WORKMODE in an all-port E1T1 MO is set to T1, LNCODE can be set to AMI or B8ZS in each singleport E1T1 MO. If no all-port E1T1 MO is configured, the default value of WORKMODE in

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

When adding an E1T1 MO, this parameter can be set to E1_COVERBOARD if SN is set to a value within the Read Only range of 0 to 5. When adding an E1T1 MO, this parameter can be set to BASE_BOARD if SN is set to 6 or 7.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an ETHOAM3AH MO, this parameter must be set to ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In an ETHOAM3AH MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the ETHOAM3AH MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD. In the Read Only ETHOAM3AH MO, this parameter can be set to a value within the range of 0 to 5 if SBT is set to ETH_COVERBOAR D.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an ETHOAM3AH MO, ERRFRMSCDEVT PRD must be Read Only greater than or equal to ERRFRMSCDEVTT HD.

N/A

N/A

N/A

In an ETHOAM3AH MO, ERRFRMSCDEVT PRD must be Read Only greater than or equal to ERRFRMSCDEVTT HD.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the ETHPORT MO, if SN is within the range from 0 to 5, this parameter must be set to ETH_COVERBOAR D. Read Only In the ETHPORT MO, if SN is set to 6 or 7, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D. In the ETHPORT MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD. In the ETHPORT MO, this parameter Read Only can be set to a value within the range of 0 to 5 if SBT is set to ETH_COVERBOAR D.

N/A

N/A

N/A

N/A

N/A

N/A

In the ETHPORT MO, if SBT is set to BASE_BOARD, this parameter can be set to COPPER, FIBER or AUTO. Read & Write In the ETHPORT MO, if SBT is set to ETH_COVERBOAR D, this parameter can be set to COPPER or FIBER.

Yes

BS

Less than 10 minutes

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

In the ETHPORT MO, if SBT and PA are set to ETH_COVERBOAR D and COPPER, respectively, this parameter can be set to 10M, 100M, 1000M, or AUTO. In the ETHPORT MO, if SBT and PA are set to ETH_COVERBOAR D and FIBER, respectively, this parameter can be set to 100M, Read & Write 1000M, or AUTO. In the ETHPORT MO, if SBT and PA are set to BASE_BOARD and COPPER, respectively, this parameter can be set to 10M, 100M, or AUTO. In the ETHPORT MO, if SBT and PA are set to BASE_BOARD and FIBER, respectively, this parameter can be In the ETHPORT MO, if SPEED is set to AUTO, this parameter must be AUTO. Read & Write In the ETHPORT MO, if SPEED is set to 10M, 100M, or 1000M, this parameter must be FULL.

Yes

All the services carried on the port

Less than 1 minute

Yes

All the services carried on the port

Less than 1 minute

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an ETHPORT MO, FERAT must be greater than or equal to FERDT.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an ETHPORT MO, FERAT must be greater than or equal to FERDT.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

All services over the member ports of the Less than 1 minute Ethernet trunk

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an ETHTRK MO, this parameter must be set to ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In an ETHTRK MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7.

N/A

N/A

N/A

None

Read & Write

Yes

All services carried on the members of Less than 1 minute the Ethernet trunk

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an ETHTRKLNK MO, this parameter can be set to a value within the range of 0 to 5 if SBT is set to ETH_COVERBOAR Read Only D. In an ETHTRKLNK MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an ETHTRKLNK MO, this parameter must be set to ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In an ETHTRKLNK MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the FLOODDEFEND MO, this parameter is valid only when DFDSW is set to ENABLE. In the FLOODDEFEND MO, if FLDTYPE is set to ARP, DFDTHD ranges from 1 to 512. Read & Write In the FLOODDEFEND MO, if FLDTYPE is set to ICMP or SYN, DFDTHD ranges from 1 to 1024. In the FLOODDEFEND MO, if FLDTYPE is set to TCP or UDP, DFDTHD ranges from 1 to 4096.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the FLOODDEFEND MO, this parameter is valid only when ALMSW is set to ENABLE. In the FLOODDEFEND MO, if FLDTYPE is set to ARP, ALMTHD ranges from 1 to 512. Read & Write In the FLOODDEFEND MO, if FLDTYPE is set to ICMP or SYN, ALMTHD ranges from 1 to 1024. In the FLOODDEFEND MO, if FLDTYPE is set to TCP or UDP, ALMTHD ranges from 1 to 4096.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

BS

Services are interrupted until the parameter is correctly set. N/A

None

Read Only

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

PEERNAME in an IKEPEER MO is case insensitive. The value of Read Only PEERNAME in an IKEPEER MO must be comprised of ASCII characters. None Read & Write

N/A

N/A

N/A

Yes

BS

Less than 1 minute

If AUTHALG in an IKEPROPOSAL MO is set to AES_XCBC_96, IKEVERSION in the Read & Write associated IKEPEER MO cannot be set to IKE_V1.

Yes

BS

Less than 1 minute

In the IKEPEER MO, this parameter is valid only when Read & Write IKEVERSION is set to IKE_V1.

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

REMOTEIP in an IKEPEER MO must be a valid IP address of class A, Read & Write B, or C. In addition, it cannot be set to 0.x.x.x or 127.x.x.x.

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

In the IKEPEER MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

Yes

BS

Less than 1 minute

In the IKEPEER MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

Yes

BS

Less than 1 minute

In the IKEPEER MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None PEERNAME in an IKEPEER6 MO is case insensitive. PEERNAME in an IKEPEER6 MO must contain only ASCII characters.

Read Only

N/A

N/A

N/A

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If AUTHALG in an IKEPROPOSAL MO is set to AES_XCBC_96, IKEVERSION in the Read & Write associated IKEPEER6 MO cannot be set to IKE_V1.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IKEPEER6 MO, this parameter is valid only when Read & Write IKEVERSION is set to IKE_V1.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an IKEPEER6 MO, REMOTEIP must be set to a global unicast address.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an IKEPEER6 MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IKEPEER6 MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IKEPEER6 MO, this parameter is valid only when Read & Write DPD is set to PERIODIC.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IKEPEER6 MO, LOCALIP must Read & Write be set to a global unicast address.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

If AUTHALG in an IKEPROPOSAL MO is set to AES_XCBC_96, IKEVERSION in the associated IKEPEER MO cannot be set to IKE_V1. Read & Write If AUTHALG in an IKEPROPOSAL MO is set to AES_XCBC_96, IKEVERSION in the associated IKEPEER6 MO cannot be set to IKE_V1.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

DSTIP in an IP2RSCGRP MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to 0.x.x.x or 127.x.x.x. In an IP2RSCGRP Read Only MO, the logic AND result of DSTIP and DSTMASK must be the same as DSTIP. That is, DSTIP must be set to a network IP address.

N/A

N/A

N/A

In an IP2RSCGRP MO, the logic AND result of DSTIP and DSTMASK must be the same as DSTIP. That is, DSTIP must be set to a network IP address. Read Only In the binary value into which DSTMASK in an IP2RSCGRP MO is converted, 0 cannot precede 1, but the value can be 255.255.255.255.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IP2RSCGRP MO, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In an IP2RSCGRP MO, this parameter can be set to BASE_BOARD, BACK_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7.

N/A

N/A

N/A

In an IP2RSCGRP MO, this parameter can be set to PPP or MPGRP if SBT is set to E1_COVERBOARD . In an IP2RSCGRP MO, this parameter can be set to ETH or ETHTRK if SBT is set to ETH_COVERBOAR D. Read Only In an IP2RSCGRP MO, this parameter can be set to PPP, MPGRP, ETH, or ETHTRK if SBT is set to BASE_BOARD. In an IP2RSCGRP MO, this parameter must be set to TUNNEL if SBT is set to BACK_BOARD.

N/A

N/A

N/A

In an IP2RSCGRP MO, this parameter can be set to a value within the range of 0 to 15 if PT is set to PPP. In an IP2RSCGRP MO, this parameter can be set to a value within the range of 0 to 3 if PT is set to MPGRP. In an IP2RSCGRP MO, this parameter can be set to a value within the range of 0 to 5 if Read Only SBT is set to ETH_COVERBOAR D and PT is set to ETH. In an IP2RSCGRP MO, this parameter can be set to a value within the range of 0 to 2 if SBT is set to ETH_COVERBOAR D and PT is set to ETHTRK. In an IP2RSCGRP MO, this parameter can be set to 0 or 1 if SBT is set to

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when ARPSPOOFCHKS Read & Write W is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when INVALIDPKTCHKS Read & Write W is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

This parameter is valid only when IPSECREPLAYCH Read & Write KSW is set to ENABLE.

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None

Read Only Read Only

N/A N/A

N/A N/A

N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

If PT in an IPITF6 MO is set to LOOPIF, the Read Only ITFTYPE cannot be set to VLAN.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the IPITF6 MO, if SN is set to 6 or 7, this parameter can Read Only be set to BASE_BOARD.

N/A

N/A

N/A

If PT in an IPITF6 MO is set to LOOPIF, the Read Only ITFTYPE cannot be set to VLAN. In the IPITF6 MO, this parameter can be set to 0 or 1 if PT is set to ETH or TRUNK and SBT is set to BASE_BOARD. In the IPITF6 MO, Read Only this parameter can be set to a value within the range of 0 to 2 if PT is set to LOOPIF and SBT is set to BASE_BOARD. In the IPITF6 MO, this parameter is valid only when ITFTYPE is set to VLAN. None

N/A

N/A

N/A

N/A

N/A

N/A

Read Only

N/A

N/A

N/A

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

In an IPPATH MO, if LOCALIP is set to 0.0.0.0, PT must be set to PPP or MPGRP. In an IPPATH MO, this parameter can be set to PPP, MPGRP, ETH, or ETHTRK if SBT is set to BASE_BOARD. In an IPPATH MO, this parameter can be set to PPP or Read & Write MPGRP if SBT is set to E1_COVERBOARD . In an IPPATH MO, this parameter can be set to ETH or ETHTRK if SBT is set to ETH_COVERBOAR D. In an IPPATH MO, this parameter must be set to TUNNEL if SBT is set to BACK_BOARD.

Yes

BS

Less than 1 minute

In an IPPATH MO, this parameter can be set to a value within the range of 0 to 15 if PT is set to PPP. In an IPPATH MO, this parameter can be set to a value within the range of 0 to 3 if PT is set to MPGRP. In an IPPATH MO, this parameter can be set to a value within the range of 0 to 5 if SBT is set to Read & Write ETH_COVERBOAR D and PT is set to ETH. In an IPPATH MO, this parameter can be set to a value within the range of 0 to 2 if SBT is set to ETH_COVERBOAR D and PT is set to ETHTRK. In an IPPATH MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD and PT is set to ETH or

Yes

BS

Less than 1 minute

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPPATH MO, this parameter is valid only when Read & Write PATHTYPE is set to QOS. LOCALIP in an IPPATH MO must be an IP address of class A, B, or C. In addition, it cannot be set to 127.x.x.x or 0.x.x.x (including 0.0.0.0). In an IPPATH MO, Read & Write LOCALIP must be different from PEERIP. In an IPPATH MO, if LOCALIP is set to 0.0.0.0, PT must be set to PPP or MPGRP. PEERIP in an IPPATH MO must be an IP address of class A, B, or C. In addition, it cannot be set to 127.x.x.x Read & Write or 0.x.x.x. In an IPPATH MO, LOCALIP must be different from PEERIP.

Yes

BS

Services are interrupted until the parameter is correctly set.

Yes

BS

Less than 1 minute

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

Interface S1 and services in the cell

Service are interrupted until the path check is disabled.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the IPPATH MO, this parameter is valid only when Read & Write JNRSCGRP is set to ENABLE. None Read & Write

Yes

BS

Less than 1 minute

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPPATH MO, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D if SN is set to a value within the Read & Write range of 0 to 5. In an IPPATH MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7.

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IPPATH6 MO, LOCALIP6 must be set to a global unicast address. Read Only In an IPPATH6 MO, LOCALIP6 and PEERIP6 cannot be the same. In an IPPATH6 MO, PEERIP6 must be set to a global unicast address. Read Only In an IPPATH6 MO, LOCALIP6 and PEERIP6 cannot be the same.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

SRCIP in an IPPATHRT MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to Read Only 0.x.x.x or 127.x.x.x. In an IPPATHRT MO, SRCIP must be different from DSTIP. DSTIP in an IPPATHRT MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to Read Only 0.x.x.x or 127.x.x.x. In an IPPATHRT MO, SRCIP must be different from DSTIP.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

NEXTHOPIP in an IPPATHRT MO must be a valid IP address of class A, Read Only B, or C. In addition, it cannot be set to 0.x.x.x or 127.x.x.x.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IPPMSESSION MO, if BINDPATH is set to NO, LOCALIP must be a valid IP address of class A, B, or C. In addition, it cannot be set to 0.x.x.x or Read Only 127.x.x.x. In an IPPMSESSION MO, if BINDPATH is set to NO, LOCALIP must be different from PEERIP. In an IPPMSESSION MO, if BINDPATH is set to NO, PEERIP must be a valid IP address of class A, B, or C. In addition, it cannot be set to 0.x.x.x or Read Only 127.x.x.x (including 0.0.0.0). In an IPPMSESSION MO, if BINDPATH is set to NO, LOCALIP must be different from PEERIP. In the IPPMSESSION MO, this parameter Read Only is valid only when BINDPATH is set to NO.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when IppmUpActState in Read Only an IPPMSESSION MO is set to PMUP.

N/A

N/A

N/A

This parameter is valid only when IppmDownActStat Read Only e in an IPPMSESSION MO is set to PMUP. This parameter is valid only when IppmDownActStat Read Only e in an IPPMSESSION MO is set to PMUP. This parameter is valid only when IppmDownActStat Read Only e in an IPPMSESSION MO is set to PMUP.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

This parameter is valid only when IppmUpActState in Read Only an IPPMSESSION MO is set to PMUP.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the IPPMSESSION MO, this parameter Read Only is valid only when BINDPATH is set to YES. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IPRT MO, this parameter can be set to BACK_BOARD, E1_COVERBOARD , or ETH_COVERBOAR D if SN is set to a value within the Read Only range of 0 to 5. In an IPRT MO, this parameter can be set to BASE_BOARD, BACK_BOARD, or ETH_COVERBOAR D if SN is set to 6 or 7.

N/A

N/A

N/A

In an IPRT MO, this parameter can be set to PPP or MPGRP if SBT is set to BASE_BOARD or E1_COVERBOARD and RTTYPE is set Read Only to IF. In an IPRT MO, this parameter must be set to TUNNEL if SBT is set to BACK_BOARD and RTTYPE is set to IF. In an IPRT MO, this parameter can be set to a value within the range of 0 to 15 if RTTYPE is set to IF and IFT is set to PPP. In an IPRT MO, this parameter can be set to a value within the range of 0 to 3 if Read Only RTTYPE is set to IF and IFT is set to MPGRP. In an IPRT MO, this parameter can be set to a value within the range of 0 to 14 if RTTYPE is set to IF and IFT is set to TUNNEL.

N/A

N/A

N/A

N/A

N/A

N/A

In an IPRT MO, this parameter must be set to NEXTHOP if SBT is set to ETH_COVERBOAR D. In an IPRT MO, this parameter must be set to IF if SBT is set to E1_COVERBOARD Read Only . In an IPRT MO, this parameter can be set to NEXTHOP or IF if SBT is set to BASE_BOARD. In an IPRT MO, this parameter must be set to If if SBT is set to BACK_BOARD. DSTIP in an IPRT MO must be a valid IP address of class A, B, or C. It can be set to 0.0.0.0, but cannot be set to 0.x.x.x or 127.x.x.x. If one of DSTMASK and DSTIP in an IPRT MO is set to Read Only 0.0.0.0, the other must be set to 0.0.0.0, too. The result of DSTIP AND DSTMASK in an IPRT MO must be equal to DSTIP. That is, DSTIP must be set to a network IP address.

N/A

N/A

N/A

N/A

N/A

N/A

In the binary value converted from DSTMASK in an IPRT MO, 0 is not allowed to precede 1. DSTMASK can be set to 0.0.0.0 or 255.255.255.255. If one of DSTMASK and DSTIP in an IPRT MO is set to Read Only 0.0.0.0, the other must be set to 0.0.0.0, too. The result of DSTIP AND DSTMASK in an IPRT MO must be equal to DSTIP. That is, DSTIP must be set to a network IP address. NEXTHOP in an IPRT MO must be a valid IP address of Class A, B, or C. In addition, it cannot be set to 127.x.x.x, 0.x.x.x, or Read Only 255.255.255.255. In the IPRT MO, this parameter is valid only when RTTYPE is set to NEXTHOP.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read & Write

Yes

BS

Less than 1 minute

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IPRT6 MO, DSTIP must be set to 0 or a global unicast address. In an IPRT6 MO, Read Only DSTIP and PFXLEN must be both 0 or a value other than 0. In an IPRT6 MO, DSTIP and PFXLEN must be both 0 or a value other than 0.

N/A

N/A

N/A

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IPRT6 MO, NEXTHOPIP must Read Only match NEXTHOPIP6TYPE .

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

BS

Less than 1 minute

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the IPSECBIND MO, if SN is within the range from 0 to 5, this parameter must be set to ETH_COVERBOAR D. Read Only In the IPSECBIND MO, if SN is set to 6 or 7, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D. In the IPSECBIND MO, this parameter is valid only when Read Only SBT is set to BASE_BOARD. In an IPSECBIND MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD and PT is set to ETH or ETHTRK. In an IPSECBIND MO, this parameter can be set to a value within the range of 0 to 5 if Read Only SBT is set to ETH_COVERBOAR D and PT is set to ETH. In an IPSECBIND MO, this parameter can be set to a value within the range of 0 to 2 if SBT is set to ETH_COVERBOAR D and PT is set to ETHTRK. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an IPSECDTNL MO, the combination of MSPGN and Read & Write MSPSN must be different from that of SSPGN and SSPSN. In an IPSECDTNL MO, the combination of MSPGN and Read & Write MSPSN must be different from that of SSPGN and SSPSN. In an IPSECDTNL MO, the combination of MSPGN and Read & Write MSPSN must be different from that of SSPGN and SSPSN.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPSECDTNL MO, the combination of MSPGN and Read & Write MSPSN must be different from that of SSPGN and SSPSN.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

SPGN in an IPSECPOLICY MO Read Only is case insensitive.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read Only

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

In the IPSECPOLICY MO, this parameter is Read & Write valid only when LTCFG is set to LOCAL.

Yes

BS

Less than 1 minute

In the IPSECPOLICY MO, this parameter is Read & Write valid only when LTCFG is set to LOCAL.

Yes

BS

Less than 1 minute

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

SPGN in an IPSECPOLICY6 MO is case insensitive.

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPSECPOLICY6 MO, this parameter Read & Write is valid only when ACLTYPE is set to IPV4.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPSECPOLICY6 MO, this parameter Read & Write is valid only when ACLTYPE is set to IPV6.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPSECPOLICY6 MO, this parameter Read & Write is valid only when LTCFG is set to LOCAL.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPSECPOLICY6 MO, this parameter Read & Write is valid only when LTCFG is set to LOCAL.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

PROPNAME in an IPSECPROPOSAL Read Only MO is case insensitive.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPSECPROPOSAL MO, TRANMODE is set to ESP or AH_ESP, Read & Write ESPAUTHALG and ESPENCALG cannot be both set to NULL.

No (And no impact on the UE in idle mode)

N/A

N/A

In the IPSECPROPOSAL MO, this parameter Read & Write is valid only when TRANMODE is set to AH or AH_ESP.

No (And no impact on the UE in idle mode)

N/A

N/A

In an IPSECPROPOSAL MO, if TRANMODE is set to ESP or AH_ESP, ESPAUTHALG and ESPENCALG cannot be both set Read & Write to NULL. In the IPSECPROPOSAL MO, this parameter is valid only when TRANMODE is set to ESP or AH_ESP. In an IPSECPROPOSAL MO, if TRANMODE is set to ESP or AH_ESP, ESPAUTHALG and ESPENCALG cannot be both set Read & Write to NULL. In the IPSECPROPOSAL MO, this parameter is valid only when TRANMODE is set to ESP or AH_ESP.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

IP in the LOCALIP MO must be set to a valid IP address of Class A, B, or C. In addition, it cannot be 127.x.x.x or 0.x.x.x. Read & Write In a LOCALIP MO, neither the network ID nor the host ID can be all 0s or 1s in the logical operation result of IP and MASK.

No (And no impact on the UE in idle mode)

N/A

N/A

In the binary value converted from MASK in the LOCALIP MO, 0 is not allowed to precede 1. MASK cannot be 0.0.0.0 or Read & Write 255.255.255.255. In a LOCALIP MO, neither the network ID nor the host ID can be all 0s or 1s in the logical operation result of IP and MASK.

No (And no impact on the UE in idle mode)

N/A

N/A

In a LOCALIP6 MO, IP6 must be a link-local address whose prefix is Read & Write greater than or equal to 10, or be a global unicast address. In a LOCALIP6 MO, if IP6 is set to the local address of Read & Write a link, PFXLEN must be greater than or equal to 10.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the LR MO, if SBT is set to E1_COVERBOARD , this parameter must be set to MPGRP. In the LR MO, if SBT is set to ETH_COVERBOAR D, this parameter can be set to ETH or ETHTRK. Read Only In the LR MO, if SBT is set to BASE_BOARD, this parameter can be set to MPGRP, ETH or ETHTRK. In the LR MO, if SBT is set to BACK_BOARD, this parameter must be set to TUNNEL.

N/A

N/A

N/A

In the LR MO, this parameter can be set to a value within the range of 0 to 3 if PT is set to MPGRP. In an LR MO, this parameter can be set to a value within the range of 0 to 14 if PT is set to TUNNEL. In the LR MO, this parameter can be set to a value within the range of 0 to 5 if PT is set to ETH Read Only and SBT is set to ETH_COVERBOAR D. In the LR MO, this parameter can be set to a value within the range of 0 to 2 if PT is set to ETHTRK and SBT is set to ETH_COVERBOAR D. In the LR MO, this parameter can be set to 0 or 1 if PT is set to ETH or ETHTRK and SBT

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the LR MO, this parameter can be set to a value within the range of 32 to 31744 if PT is set to MPGRP. In the LR MO, this parameter can be set to a value within the range of 32 to 360000 if PT is set to TUNNEL. In the LR MO, this parameter can be set to a value within Read & Write the range of 32 to 1000000 if PT is set to ETH or ETHTRK and SBT is set to ETH_COVERBOAR D. In the LR MO, this parameter can be set to a value within the range of 32 to 360000 if PT is set to ETH or ETHTRK and SBT is set to BASE_BOARD.

No (And no impact on the UE in idle mode)

N/A

N/A

In the LR MO, this parameter can be set to a value within the range of 32 to 155000 if PT is set to MPGRP. In the LR MO, this parameter can be set to a value within the range of 32 to 300000 if PT is set to TUNNEL. In the LR MO, this parameter can be set to a value within Read & Write the range of 32 to 1000000 if PT is set to ETH or ETHTRK and SBT is set to ETH_COVERBOAR D. In the LR MO, this parameter can be set to a value within the range of 32 to 300000 if PT is set to ETH or ETHTRK and SBT is set to BASE_BOARD.

No (And no impact on the UE in idle mode)

N/A

N/A

In the LR MO, this parameter can be set to a value within the range of 0 to 155000 if PT is set to MPGRP. In the LR MO, this parameter can be set to a value within the range of 0 to 300000 if PT is set to TUNNEL. In the LR MO, this parameter can be set to a value within Read & Write the range of 0 to 1000000 if PT is set to ETH or ETHTRK and SBT is set to ETH_COVERBOAR D. In the LR MO, this parameter can be set to a value within the range of 0 to 300000 if PT is set to ETH or ETHTRK and SBT is set to BASE_BOARD. In an LR MO, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In an LR MO, this parameter can be set to BASE_BOARD, BACK_BOARD, or ETH_COVERBOAR D if SN is set to 6 or 7.

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

In the LR MO, this parameter can be set to a value within the range of 32 to 31744 if PT is set to MPGRP. In the LR MO, this parameter can be set to a value within the range of 32 to 540000 if PT is set to TUNNEL. In the LR MO, this parameter can be set to a value within Read & Write the range of 32 to 1000000 if PT is set to ETH or ETHTRK and SBT is set to ETH_COVERBOAR D. In the LR MO, this parameter can be set to a value within the range of 32 to 540000 if PT is set to ETH or ETHTRK and SBT is set to BASE_BOARD.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the MPGRP MO, this parameter can be set to a value Read Only within the range of 0 to 3 if SBT is set to BASE_BOARD.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the MPGRP MO, this parameter is valid only when Read Only AUTH is set to PAP or CHAP. In the MPGRP MO, this parameter is valid only when Read Only AUTH is set to PAP or CHAP.

N/A

N/A

N/A

N/A

N/A

N/A

LOCALIP in an MPGRP MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to the reserved IP addresses 0.x.x.x or 127.x.x.x but can be set to 0.0.0.0. In the MPGRP MO, IPMASK cannot be all 0s if LOCALIP is not all 0s. In an MPGRP MO, Read Only neither the network ID nor the host ID can be all 0s or 1s in the logical operation result of LOCALIP and IPMASK. In an MPGRP MO, LOCALIP must be different from PEERIP. In the MPGRP MO, IPMASK must be all 0s if LOCALIP is all 0s.

N/A

N/A

N/A

IPMASK in the MPGRP MO must be valid, that is, 0 is not allowed to precede 1. In addition, it can be set to 0.0.0.0 or 255.255.255.255. In the MPGRP MO, IPMASK cannot be all 0s if LOCALIP is not all 0s. In an MPGRP MO, neither the network Read Only ID nor the host ID can be all 0s or 1s in the logical operation result of LOCALIP and IPMASK. In an MPGRP MO, LOCALIP must be different from PEERIP. In the MPGRP MO, IPMASK must be all 0s if LOCALIP is all 0s.

N/A

N/A

N/A

PEERIP in an MPGRP MO must be a valid IP address of class A, B, or C. In addition, Read Only it cannot be set to the reserved IP addresses 0.x.x.x or 127.x.x.x but can be set to 0.0.0.0.

N/A

N/A

N/A

In the MPGRP MO, this parameter is valid only when Read Only MCPPP is set to ENABLE.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the MPGRP MO, MAXMFLEN must be larger than MAXSFLEN and the minimum Read Only difference is 2. In the MPGRP MO, this parameter is valid only when MUXCP is set to ENABLE.

N/A

N/A

N/A

In the MPGRP MO, MAXMFLEN must be larger than MAXSFLEN and the minimum Read Only difference is 2. In the MPGRP MO, this parameter is valid only when MUXCP is set to ENABLE.

N/A

N/A

N/A

In the MPGRP MO, this parameter is valid only when Read Only MUXCP is set to ENABLE.

N/A

N/A

N/A

In the MPGRP MO, if MCPPP is set to ENABLE and MHO is set to LONG, this parameter can be set to 4 or 8. Read Only In the MPGRP MO, if MCPPP is set to ENABLE and MHO is set to SHORT, this parameter must be set to 4.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the MPGRP MO, MPDAAT must be Read Only greater than or equal to MPDADT. In the MPGRP MO, MPDAAT must be Read Only greater than or equal to MPDADT.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None None None

Read Only Read Only Read Only

N/A N/A N/A

N/A N/A N/A

N/A N/A N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the MPGRP MO, if the value of SN is within the range from 0 to 5, this parameter must be set to E1_COVERBOARD Read Only . In the MPGRP MO, if SN is set to 6 or 7, this parameter must be set to BASE_BOARD.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an MPLNK MO, SRN must be the Read Only same as E1T1SRN.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the MPLNK MO, this parameter is valid only when SN Read Only and SBT are both set to valid values. In the MPLNK MO, this parameter is valid only when SN Read Only and SBT are both set to valid values.

N/A

N/A

N/A

N/A

N/A

N/A

In an MPLNK MO, Read Only SRN must be the same as E1T1SRN.

N/A

N/A

N/A

In the MPLNK MO, this parameter is valid only when SN Read Only and SBT are both set to valid values.

N/A

N/A

N/A

In the MPLNK MO, this parameter is valid only when SN, Read Only SBT, E1T1SN, and E1T1SBT are all set to valid values.

N/A

N/A

N/A

The value range of TSN in an MPLNK MO varies with the setting of WORKMODE: (1) If WORKMODE in the associated E1T1 MO is set to Read Only E1_UNBA or E1_BA, the value range is from TS1 to TS31; (2) If WORKMODE in the associated E1T1 MO is set to T1, the value range is from TS1 to TS24.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an MPLNK MO, if E1T1SN is the same as SN, E1T1SBT must be the same as SBT. In the MPLNK MO, this parameter must be set to E1_COVERBOARD Read Only if the value of SN is within the range of 0 to 5. In the MPLNK MO, this parameter must be set to BASE_BOARD if the value of SN is 6 or 7.

N/A

N/A

N/A

In the MPLNK MO, this parameter is valid only when SN Read Only and SBT are both set to valid values.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an MPLNK MO, if E1T1SN is the same as SN, E1T1SBT must be the same as SBT. In the MPLNK MO, Read Only this parameter is valid only when SN, SBT, E1T1SN are all set to valid values. None Read Only

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

IP in the OMCH MO must be a valid IP address of Class A, B, or C, and cannot be set to 127.X.X.X or 0.X.X.X. In an OMCH MO, if MASK is set to a value other than 255.255.255.255, neither the network ID nor the host ID can be all 0s or all 1s in the logical operation result of Read & Write IP and MASK. In an OMCH MO, IP must be different from PEERIP. In an OMCH MO, NEXTHOP must be different from IP. In an OMCH MO, if BEAR and BRT are set to IPV4 and YES, respectively, DSTIP must be different from IP. MASK in an OMCH MO must be set to a valid mask (0 is not allowed to precede 1). In an OMCH MO, this parameter can be set to 255.255.255.255 when BEAR is set to IPV4. Read & Write In an OMCH MO, if MASK is set to a value other than 255.255.255.255, neither the network ID nor the host ID can be all 0s or all 1s in the logical operation result of IP and MASK.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

PEERIP in the OMCH MO must be a valid IP address of Class A, B, or C, and cannot be set to 127.X.X.X or 0.X.X.X. In an OMCH MO, if PEERMASK is not set to 255.255.255.255, Read & Write neither the network ID nor the host ID can be all 0s or all 1s in the logical operation result of PEERIP and PEERMASK. In an OMCH MO, IP must be different from PEERIP. PEERMASK in an OMCH MO must be set to a valid mask (0 is not allowed to precede 1). In an OMCH MO, this parameter can be set to 255.255.255.255 when BEAR is set to IPV4. Read & Write In an OMCH MO, if PEERMASK is not set to 255.255.255.255, neither the network ID nor the host ID can be all 0s or all 1s in the logical operation result of PEERIP and PEERMASK.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

In the OMCH MO, this parameter is valid only when BEAR is set to Read & Write IPV4, and SN and SBT are set to valid values.

No (And no impact on the UE in idle mode)

N/A

N/A

In an OMCH MO, if BRT is set to YES, DSTIP must be a valid IP address of class A, B, or C. In addition, it cannot be set to the reserved IP addresses 127.x.x.x or 0.x.x.x but can be set to 0.0.0.0. In an OMCH MO, if BRT is set to YES and one of DSTIP and DSTMASK is set to 0.0.0.0, the other must be set to Read & Write 0.0.0.0. In an OMCH MO, if BRT is set to YES, the logical AND operation result between DSTIP and DSTMASK in the OMCH MO must be equal to DSTIP. That is, DSTIP in the OMCH MO must be set to a network IP address. In an OMCH MO, if BEAR and BRT are set to IPV4 and YES, respectively,

No (And no impact on the UE in idle mode)

N/A

N/A

In the OMCH MO, this parameter is valid only when Read & Write BEAR is set to IPV4 and BRT is set to YES.

No (And no impact on the UE in idle mode)

N/A

N/A

In an OMCH MO, this parameter must be set to NEXTHOP if SBT and BRT are set to ETH_COVERBOAR D and YES, respectively. In an OMCH MO, this parameter can be set to NEXTHOP Read & Write or IF if SBT and BRT are set to BASE_BOAR and YES, respectively. In an OMCH MO, this parameter must be set to IF if SBT and BRT are set to BACK_BOAR and YES, respectively. In an OMCH MO, this parameter can be set to PPP or MPGRP if SBT is set to BASE_BOARD, BRT is set to YES, and RT is set to IF. Read & Write In an OMCH MO, this parameter must be set to TUNNEL if SBT is set to BACK_BOARD, BRT is set to YES, and RT is set to IF.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In an OMCH MO, this parameter can be set to a value within the range of 0 to 15 if IFT is set to PPP. In an OMCH MO, this parameter can be set to a value Read & Write within the range of 0 to 3 if IFT is set to MPGRP. In an OMCH MO, this parameter can be set to a value within the range of 0 to 14 if IFT is set to TUNNEL.

No (And no impact on the UE in idle mode)

N/A

N/A

In the OMCH MO, this parameter is valid only when BRT is set to YES.

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an OMCH MO, NEXTHOP must be different from IP. In the OMCH MO, Read & Write this parameter is valid only when RT is set to NEXTHOP.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an OMCH MO, this parameter must be set to ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read & Write In an OMCH MO, this parameter can be set to BASE_BOARD, BACK_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7. In an OMCH6 MO, LOCALIP6 must be set to a global unicast address. Read Only In the OMCH6 MO, LOCALIP6 cannot be the same as PEERIP6. In an OMCH6 MO, PEERIP6 must be set to a global unicast address. Read & Write In the OMCH6 MO, LOCALIP6 cannot be the same as PEERIP6.

No (And no impact on the UE in idle mode)

N/A

N/A

N/A

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a PACKETFILTER MO, this parameter can be set to any value within the range of 0 to 5 if SBT is set to ETH_COVERBOAR D and PT is set to ETH. In a PACKETFILTER MO, this parameter can be set to any value within the range of 0 to 2 if SBT is set to Read Only ETH_COVERBOAR D and PT is set to ETHTRK. In a PACKETFILTER MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD and PT is set to ETH or ETHTRK. In a PACKETFILTER MO, this parameter can be set to any value within the range of 0 to 14 if

N/A

N/A

N/A

This parameter is valid only when FM Read Only is set to ADV_ACL or ADV_AND_L2.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a PACKETFILTER MO, this parameter must be set to ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. In a Read Only PACKETFILTER MO, this parameter can be set to BASE_BOARD, ETH_COVERBOAR D, or BACK_BOARD if SN is set to 6 or 7.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

This parameter is valid only when FM Read Only is set to L2_ACL or ADV_AND_L2.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

IP in a PINGFILTER MO must be a valid IP address of class A, Read Only B, or C. In addition, it cannot be set to 0.x.x.x or 127.x.x.x.

N/A

N/A

N/A

In the binary value into which MASK in a PINGFILTER MO is converted, 0 cannot precede 1. Read Only In addition, MASK can be 255.255.255.255, but cannot be 0.0.0.0.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode) No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a PORTSECURITY MO, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D if SN is set to a value within the Read Only range of 0 to 5. In a PORTSECURITY MO, this parameter can be set to BASE_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7.

N/A

N/A

N/A

In a PORTSECURITY MO, this parameter can be set to ETH or E1T1 if SBT is set to BASE_BOARD. In a PORTSECURITY MO, this parameter must be set to E1T1 Read Only if SBT is set to E1_COVERBOARD . In a PORTSECURITY MO, this parameter must be set to ETH if SBT is set to ETH_COVERBOAR D.

N/A

N/A

N/A

In the PORTSECURITY MO, this parameter can be set to 0 or 1 if SBT is set to BASE_BOARD and PT is set to ETH. In the PORTSECURITY MO, this parameter can be set to a value within the range of 0 to 3 if SBT is set to BASE_BOARD and PT is set to E1T1. In the Read Only PORTSECURITY MO, this parameter can be set to a value within the range of 0 to 7 if SBT is set to E1_COVERBOARD and PT is set to E1T1. In the PORTSECURITY MO, this parameter can be set to a value within the range of 0 to 5 if SBT is set to ETH_COVERBOAR

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the PPPLNK MO, this parameter is valid only when SN Read Only and SBT are both set to valid values. In the PPPLNK MO, this parameter is valid only when SN Read Only and SBT are both set to valid values.

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the PPPLNK MO, this parameter is valid only when Read Only AUTH is set to PAP or CHAP. In the PPPLNK MO, this parameter is valid only when Read Only AUTH is set to PAP or CHAP.

N/A

N/A

N/A

N/A

N/A

N/A

The value range of TSN in a PPPLNK MO varies with the setting of WORKMODE: (1) If WORKMODE in the associated E1T1 MO is set to Read Only E1_UNBA or E1_BA, the value range is from TS1 to TS31; (2) If WORKMODE in the associated E1T1 MO is set to T1, the value range is from TS1 to TS24.

N/A

N/A

N/A

LOCALIP in a PPPLNK MO must be a valid IP address of class A, B, or C. In addition, it cannot be set to the reserved IP addresses 0.x.x.x or 127.x.x.x but can be set to 0.0.0.0. In the PPPLNK MO, IPMASK cannot be set to 0.0.0.0 if LOCALIP is not set to 0.0.0.0. In the PPPLNK MO, IPMASK must be Read Only set to 0.0.0.0 if LOCALIP is set to 0.0.0.0. In the logical operation result of LOCALIP and IPMASK in a PPPLNK MO, neither the network ID nor host ID can be all 0s or 1s after being converted into a binary value. In a PPPLNK MO, LOCALIP must be different from PEERIP.

N/A

N/A

N/A

IPMASK in the PPPLNK MO must be valid, that is, 0 is not allowed to precede 1. In addition, it can be set to 0.0.0.0 or 255.255.255.255. In the PPPLNK MO, IPMASK cannot be set to 0.0.0.0 if LOCALIP is not set to 0.0.0.0. In the PPPLNK MO, IPMASK must be set to 0.0.0.0 if Read Only LOCALIP is set to 0.0.0.0. In the logical operation result of LOCALIP and IPMASK in a PPPLNK MO, neither the network ID nor host ID can be all 0s or 1s after being converted into a binary value. In a PPPLNK MO, LOCALIP must be different from PEERIP.

N/A

N/A

N/A

PEERIP in a PPPLNK MO must be a valid IP address of class A, B, or C. In addition, Read Only it can be set to 0.0.0.0, but cannot be set to the reserved IP addresses 0.x.x.x or 127.x.x.x.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the PPPLNK MO, MAXMFLEN must be larger than MAXSFLEN and the minimum Read Only difference is 2. In the PPPLNK MO, this parameter is valid only when MUXCP is set to ENABLE.

N/A

N/A

N/A

In the PPPLNK MO, MAXMFLEN must be larger than MAXSFLEN and the minimum difference is 2. In the PPPLNK MO, MRU must be Read Only greater than or equal to MAXMFLEN. In the PPPLNK MO, this parameter is valid only when MUXCP is set to ENABLE.

N/A

N/A

N/A

In the PPPLNK MO, this parameter is valid only when Read Only MUXCP is set to ENABLE.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the PPPLNK MO, MRU must be Read Only greater than or equal to MAXMFLEN.

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the PPPLNK MO, FFDPHOLD must Read Only be smaller than FFAPHOLD. In the PPPLNK MO, FFDPHOLD must Read Only be smaller than FFAPHOLD. In the PPPLINK MO, this parameter must be set to E1_COVERBOARD if the value of SN is within the range of 0 Read Only to 5. In the PPPLINK MO, this parameter must be set to BASE_BOARD if SN is set to 6 or 7.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In a PRI2QUE MO, PRI0 must be Read & Write greater than or equal to PRI1.

No (And no impact on the UE in idle mode)

N/A

N/A

In a PRI2QUE MO, PRI0 must be greater than or equal to PRI1. Read & Write In a PRI2QUE MO, PRI1 must be greater than or equal to PRI2.

No (And no impact on the UE in idle mode)

N/A

N/A

In a PRI2QUE MO, PRI1 must be greater than or equal to PRI2. Read & Write In a PRI2QUE MO, PRI2 must be greater than or equal to PRI3.

No (And no impact on the UE in idle mode)

N/A

N/A

In a PRI2QUE MO, PRI2 must be greater than or equal to PRI3. Read & Write In a PRI2QUE MO, PRI3 must be greater than or equal to PRI4.

No (And no impact on the UE in idle mode)

N/A

N/A

In a PRI2QUE MO, PRI3 must be greater than or equal to PRI4. Read & Write In a PRI2QUE MO, PRI4 must be greater than or equal to PRI5.

No (And no impact on the UE in idle mode)

N/A

N/A

In a PRI2QUE MO, PRI4 must be greater than or equal to PRI5. Read & Write In a PRI2QUE MO, PRI5 must be greater than or equal to PRI6.

No (And no impact on the UE in idle mode)

N/A

N/A

In a PRI2QUE MO, PRI5 must be Read & Write greater than or equal to PRI6.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In an RSCGRP MO, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D if SN is set to a value within the range of 0 to 5. Read Only In an RSCGRP MO, this parameter can be set to BASE_BOARD, BACK_BOARD or ETH_COVERBOAR D if SN is set to 6 or 7. In an RSCGRP MO, this parameter can be set to PPP, MPGRP, ETH, or ETHTRK if SBT is set to BASE_BOARD. In an RSCGRP MO, this parameter can be set to TUNNEL if SBT is set to BACK_BOARD. In an RSCGRP MO, Read Only this parameter can be set to PPP or MPGRP if SBT is set to E1_COVERBOARD . In an RSCGRP MO, this parameter can be set to ETH or ETHTRK if SBT is set to ETH_COVERBOAR D.

N/A

N/A

N/A

N/A

N/A

N/A

In an RSCGRP MO, this parameter can be set to a value within the range of 0 to 3 if PT is set to MPGRP. In an RSCGRP MO, this parameter can be set to a value within the range of 0 to 15 if PT is set to PPP. In an RSCGRP MO, this parameter can be set to a value within the range of 0 to 5 if SBT is set to Read Only ETH_COVERBOAR D and PT is set to ETH. In an RSCGRP MO, this parameter can be set to a value within the range of 0 to 2 if SBT is set to ETH_COVERBOAR D and PT is set to ETHTRK. In an RSCGRP MO, this parameter can be set to a value within the range of 0 to 1 if SBT is set to BASE_BOARD and

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the RSCGRP MO, this parameter must be set to Read & Write KBPS if BEAR is set to IP.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, TXCBS must be greater than or equal to TXBW. In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 1000000 if PT is set to TUNNEL. In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 1000000 if PT is set to ETH or ETHTRK. Read & Write In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 150000 if SBT is set to E1_COVERBOARD and PT is set to PPP or MPGRP. In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 1984 if SBT is set to BASE_BOARD and PT is set to PPP.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 1000000 if PT is set to TUNNEL. In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 1000000 if PT is set to ETH or ETHTRK. In an RSCGRP MO, this parameter can be set to any value within the range of Read & Write 32 to 540000 if SBT is set to E1_COVERBOARD and PT is set to PPP or MPGRP. In an RSCGRP MO, this parameter can be set to any value within the range of 32 to 1984 if SBT is set to BASE_BOARD and PT is set to PPP. In an RSCGRP MO, this parameter can be set to any value within the range of

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, TXCBS must be greater than or equal to TXBW. In an RSCGRP MO, TXCBS must be greater than or equal to TXCIR. In an RSCGRP MO, TXPBS must be greater than or equal to TXCBS. In an RSCGRP MO, this parameter can be set to any value within the range of 64 to 1000000 if PT Read & Write is set to TUNNEL. In an RSCGRP MO, this parameter can be set to any value within the range of 64 to 1000000 if PT is set to ETH or ETHTRK. In an RSCGRP MO, this parameter can be set to any value within the range of 64 to 200000 if SBT is set to E1_COVERBOARD and PT is set to PPP or MPGRP.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, this parameter can be set to any value within the range of 64 to 1000000 if PT is set to TUNNEL. In an RSCGRP MO, this parameter can be set to any value within the range of 64 to 1000000 if PT is set to ETH or ETHTRK. In an RSCGRP MO, this parameter can be set to any value within the range of Read & Write 64 to 450000 if SBT is set to E1_COVERBOARD and PT is set to PPP or MPGRP. In an RSCGRP MO, this parameter can be set to any value within the range of 64 to 3968 if SBT is set to BASE_BOARD and PT is set to PPP. In an RSCGRP MO, this parameter can be set to any value within the range of

No (And no impact on the UE in idle mode)

N/A

N/A

In the RSCGRP MO, this parameter Read Only is valid only when BEAR is set to IP.

N/A

N/A

N/A

In the RSCGRP MO, this parameter Read & Write is valid only when BEAR is set to IP.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, TXCBS must be greater than or equal to TXCIR. Read & Write In an RSCGRP MO, TXPIR must be greater than or equal to TXCIR.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, RXPIR must be Read & Write greater than or equal to RXCIR.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, TXPBS must be greater than or equal to TXPIR. Read & Write In an RSCGRP MO, TXPIR must be greater than or equal to TXCIR.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, RXPIR must be Read & Write greater than or equal to RXCIR.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRP MO, TXPBS must be greater than or equal to TXPIR. Read & Write In an RSCGRP MO, TXPBS must be greater than or equal to TXCBS.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the RSCGRPALG MO, if SN is within the range from 0 to 5, this parameter can be set to E1_COVERBOARD or ETH_COVERBOAR D. Read Only In the RSCGRPALG MO, if SN is set to 6 or 7, this parameter can be set to BASE_BOARD, BACK_BOARD, or ETH_COVERBOAR D.

N/A

N/A

N/A

In the RSCGRPALG MO, if SBT is set to BASE_BOARD, this parameter can be set to PPP, MPGRP, ETH, or ETHTRK. In the RSCGRPALG MO, if SBT is set to BACK_BOARD, this parameter can be set to TUNNEL. Read Only In the RSCGRPALG MO, if SBT is set to E1_COVERBOARD , this parameter can be set to PPP or MPGRP. In the RSCGRPALG MO, if SBT is set to ETH_COVERBOAR D, this parameter can be set to ETH or ETHTRK.

N/A

N/A

N/A

In the RSCGRPALG MO, if PT is set to PPP, the value range of this parameter is from 0 to 15. In the RSCGRPALG MO, if PT is set to MPGRP, the value range of this parameter is from 0 to 3. In the RSCGRPALG MO, if SBT is set to BASE_BOARD and Read Only PT is set to ETH, this parameter can be set to 0 or 1. In the RSCGRPALG MO, if SBT is set to ETH_COVERBOAR D and PT is set to ETH, the value range of this parameter is from 0 to 5. In the RSCGRPALG MO, if SBT is set to BASE_BOARD and PT is set to

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRPALG MO, CCTTH must Read & Write be smaller than CTTH.

No (And no impact on the UE in idle mode)

N/A

N/A

In an RSCGRPALG MO, CCTTH must Read & Write be smaller than CTTH.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

N/A

N/A

The LOCIP parameter in the SCTPLNK MO must be a valid IP address of Class A, B, or C. In addition, it cannot be set to 127.x.x.x or 0.x.x.x. In an SCTPLNK MO, LOCIP, SECLOCIP, PEERIP, and Read & Write SECPEERIP must be mutually different with the IP address of 0.0.0.0 being excluded. That is, SECLOCIP and SECPEERIP can be both set to 0.0.0.0, while neither LOCIP nor PEERIP can be set to 0.0.0.0.

Yes

BS

Less than 1 minute

SECLOCIP in the SCTPLNK MO must be a valid IP address of Class A, B, or C. In addition, it cannot be set to 127.x.x.x or 0.x.x.x, but can be set to 0.0.0.0. In an SCTPLNK MO, LOCIP, SECLOCIP, Read & Write PEERIP, and SECPEERIP must be mutually different with the IP address of 0.0.0.0 being excluded. That is, SECLOCIP and SECPEERIP can be both set to 0.0.0.0, while neither LOCIP nor PEERIP can be set to 0.0.0.0. None Read & Write

Yes

BS

Less than 1 minute

Yes

BS

Less than 1 minute

PEERIP in the SCTPLNK MO must be a valid IP address of Class A, B, or C. In addition, it cannot be set to 127.x.x.x or 0.x.x.x. In an SCTPLNK MO, LOCIP, SECLOCIP, PEERIP, and SECPEERIP must Read & Write be mutually different with the IP address of 0.0.0.0 being excluded. That is, SECLOCIP and SECPEERIP can be both set to 0.0.0.0, while neither LOCIP nor PEERIP can be set to 0.0.0.0.

Yes

BS

Less than 1 minute

SECPEERIP in the SCTPLNK MO must be a valid IP address of Class A, B, or C. In addition, it cannot be set to 127.x.x.x or 0.x.x.x, but can be set to 0.0.0.0. In an SCTPLNK MO, LOCIP, SECLOCIP, Read & Write PEERIP, and SECPEERIP must be mutually different with the IP address of 0.0.0.0 being excluded. That is, SECLOCIP and SECPEERIP can be both set to 0.0.0.0, while neither LOCIP nor PEERIP can be set to 0.0.0.0. None Read & Write

Yes

BS

Less than 1 minute

Yes

BS

Less than 1 minute

In an SCTPLNK MO, RTOINIT must be greater than or Read & Write equal to RTOMIN and smaller than RTOMAX.

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK MO, RTOINIT must be greater than or Read & Write equal to RTOMIN and smaller than RTOMAX.

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK MO, RTOINIT must be greater than or Read & Write equal to RTOMIN and smaller than RTOMAX.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK MO, MAXASSOCRETR Read & Write must be larger than MAXPATHRETR.

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK MO, MAXASSOCRETR Read & Write must be larger than MAXPATHRETR.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In the SCTPLNK MO, this parameter is valid only when Read & Write AUTOSWITCH is set to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK6 MO, LOCIP, SECLOCIP, PEERIP, and SECPEERIP must be mutually different with the IP address Read & Write of 0 being excluded. That is, SECLOCIP and SECPEERIP can be both set to 0, while neither LOCIP nor PEERIP can be set to 0. In an SCTPLNK6 MO, LOCIP, SECLOCIP, PEERIP, and SECPEERIP must be mutually different with the IP address Read & Write of 0 being excluded. That is, SECLOCIP and SECPEERIP can be both set to 0, while neither LOCIP nor PEERIP can be set to 0.

Yes

BS

Less than 1 minute

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

In an SCTPLNK6 MO, LOCIP, SECLOCIP, PEERIP, and SECPEERIP must be mutually different with the IP address of 0 being excluded. That is, SECLOCIP Read & Write and SECPEERIP can be both set to 0, while neither LOCIP nor PEERIP can be set to 0. In an SCTPLNK6 MO, PEERIP must be set to a global unicast address. In an SCTPLNK6 MO, LOCIP, SECLOCIP, PEERIP, and SECPEERIP must be mutually different with the IP address of 0 being excluded. That is, SECLOCIP Read & Write and SECPEERIP can be both set to 0, while neither LOCIP nor PEERIP can be set to 0. In an SCTPLNK6 MO, SECPEERIP must be set to a global unicast address.

Yes

BS

Less than 1 minute

Yes

BS

Less than 1 minute

None

Read & Write

Yes

BS

Less than 1 minute

In an SCTPLNK6 MO, RTOINIT must be greater than or Read & Write equal to RTOMIN and smaller than RTOMAX.

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK6 MO, RTOINIT must be greater than or Read & Write equal to RTOMIN and smaller than RTOMAX.

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK6 MO, RTOINIT must be greater than or Read & Write equal to RTOMIN and smaller than RTOMAX.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK6 MO, MAXASSOCRETR Read & Write must be larger than MAXPATHRETR.

No (And no impact on the UE in idle mode)

N/A

N/A

In an SCTPLNK6 MO, MAXASSOCRETR Read & Write must be larger than MAXPATHRETR.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

IP in the SUBNETVLAN MO must be a valid IP address of class A, Read Only B, or C. In addition, It cannot be set to 127.x.x.x or 0.x.x.x.

N/A

N/A

N/A

MASK in the SUBNETVLAN MO Read Only must be all 1s.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMULHOCACTH must be greater Read & Write than or equal to TRMULGOLDCAC TH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMDLHOCACTH must be greater Read & Write than or equal to TRMDLGOLDCAC TH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMULHOCACTH must be greater than or equal to TRMULGOLDCAC TH. Read & Write In a TACALG MO, TRMULGOLDCAC TH must be greater than or equal to TRMULSILVERCA CTH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMDLHOCACTH must be greater than or equal to TRMDLGOLDCAC TH. Read & Write In a TACALG MO, TRMDLGOLDCAC TH must be greater than or equal to TRMDLSILVERCA CTH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMULGOLDCAC TH must be greater than or equal to TRMULSILVERCA CTH. In a TACALG MO, Read & Write TRMULSILVERCA CTH must be greater than or equal to TRMULBRONZEC ACTH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMDLGOLDCAC TH must be greater than or equal to TRMDLSILVERCA CTH. In a TACALG MO, Read & Write TRMDLSILVERCA CTH must be greater than or equal to TRMDLBRONZEC ACTH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMULSILVERCA CTH must be Read & Write greater than or equal to TRMULBRONZEC ACTH.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TACALG MO, TRMDLSILVERCA CTH must be Read & Write greater than or equal to TRMDLBRONZEC ACTH.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMULLDRTRGT H must be greater Read & Write than TRMULLDRCLRTH .

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMDLLDRTRGT H must be greater Read & Write than TRMDLLDRCLRTH .

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMULLDRTRGT H must be greater than TRMULLDRCLRTH . Read & Write In a TLDRALG MO, TRMULLDRCLRTH must be greater than TRMULMLDTRGT H.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMDLLDRTRGT H must be greater than TRMDLLDRCLRTH . Read & Write In a TLDRALG MO, TRMDLLDRCLRTH must be greater than TRMDLMLDTRGT H.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMULLDRCLRTH must be greater than TRMULMLDTRGT H. Read & Write In a TLDRALG MO, TRMULMLDTRGT H must be greater than TRMULMLDCLRT H.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMDLLDRCLRTH must be greater than TRMDLMLDTRGT H. Read & Write In a TLDRALG MO, TRMDLMLDTRGT H must be greater than TRMDLMLDCLRT H.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMULMLDTRGT H must be greater Read & Write than TRMULMLDCLRT H.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TLDRALG MO, TRMDLMLDTRGT H must be greater Read & Write than TRMDLMLDCLRT H.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

When TRMULOLCSWITC H in the TOLCALG MO is set to ON, the QoS of highpriority services can be ensured in the case of transport overload in the uplink. When Read & Write TRMULOLCSWITC H in the TOLCALG MO is set to OFF, the QoS of highpriority services cannot be ensured in the case of transport overload in the uplink.

No (And no impact on the UE in idle mode)

N/A

N/A

If TRMDLOLCSWITC H in the TOLCALG MO is set to ON, the qualities of highpriority services are ensured. If TRMDLOLCSWITC Read & Write H in the TOLCALG MO is set to OFF, the qualities of highpriority services may deteriorate in the case of transport overload in the downlink.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TOLCALG MO, TRMULOLCTRIGT H must be greater than TRMULOLCRELTH . Read & Write In the TOLCALG MO, TRMULOLCTRIGT H is valid only when TRMULOLCSWITC H is set to ON.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TOLCALG MO, TRMULOLCTRIGT H must be greater than TRMULOLCRELTH Read & Write . In the TOLCALG MO, this parameter is valid only when TRMULOLCSWITC H is set to ON.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a TOLCALG MO, TRMDLOLCTRIGT H must be greater than TRMDLOLCRELTH Read & Write . In the TOLCALG MO, this parameter is valid only when TRMDLOLCSWITC H is set to ON.

No (And no impact on the UE in idle mode)

N/A

N/A

In a TOLCALG MO, TRMDLOLCTRIGT H must be greater than TRMDLOLCRELTH . Read & Write In the TOLCALG MO, TRMDLOLCRELTH is valid only when TRMDLOLCSWITC H is set to ON.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

Each TUNNEL MO must have a unique combination of Read Only SCN, DCN, SSRN, DSRN, SSN, and DSN. Each TUNNEL MO must have a unique combination of Read Only SCN, DCN, SSRN, DSRN, SSN, and DSN. Each TUNNEL MO must have a unique combination of Read Only SCN, DCN, SSRN, DSRN, SSN, and DSN.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

Each TUNNEL MO must have a unique combination of Read & Write SCN, DCN, SSRN, DSRN, SSN, and DSN. Each TUNNEL MO must have a unique combination of Read & Write SCN, DCN, SSRN, DSRN, SSN, and DSN. Each TUNNEL MO must have a unique combination of Read & Write SCN, DCN, SSRN, DSRN, SSN, and DSN.

Yes

BS

Services are interrupted until the parameter is correctly set.

Yes

BS

Services are interrupted until the parameter is correctly set.

Yes

BS

Services are interrupted until the parameter is correctly set.

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

None

Read Only

N/A

N/A

N/A

In the VLANCLASS MO, this parameter is valid only when Read Only TRAFFIC is set to USERDATA.

N/A

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

In a VLANMAP MO, NEXTHOPIP must be a valid IP address of class A, Read Only B, or C. In addition, it cannot be set to 0.x.x.x or 127.x.x.x. In the binary value into which MASK in a VLANMAP MO is converted, 0 cannot precede 1. In addition, MASK can be 255.255.255.255, Read Only but cannot be 0.0.0.0. In a VLANMAP MO, the logical AND result of NEXTHOPIP and MASK cannot be 0.

N/A

N/A

N/A

N/A

N/A

N/A

This parameter must be set to a valid value when Read & Write the VLANMAP MO is being modified.

No (And no impact on the UE in idle mode)

N/A

N/A

In the VLANMAP MO, this parameter is valid only when Read & Write VLANMODE is set to SINGLEVLAN. In the VLANMAP MO, this parameter is valid only when VLANMODE is set to SINGLEVLAN. This parameter is valid when the Read & Write VLANMAP MO is being modified and SETPRIO is changed from DISABLE to ENABLE.

No (And no impact on the UE in idle mode)

N/A

N/A

No (And no impact on the UE in idle mode)

N/A

N/A

In the VLANMAP MO, this parameter is valid only when VLANMODE is set to VLANGROUP. This parameter is valid when the Read & Write VLANMAP MO is being modified and VLANMODE is changed from SINGLEVLAN to VLANGROUP.

No (And no impact on the UE in idle mode)

N/A

N/A

In the VLANMAP MO, this parameter is valid only when Read & Write VLANMODE is set to SINGLEVLAN.

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

None

Read & Write

No (And no impact on the UE in idle mode)

N/A

N/A

Caution

Validation of Modification

Impact on Radio Network Performance

Introduced in Version...

Attribute

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. N/A None

V100R004C00

Equipment

None

V100R001C00

Equipment

None

V100R001C00

Equipment

None

V100R004C00

Equipment

None

V100R004C00

Equipment

None

V100R001C00

Equipment

None

V100R001C00

Equipment

None

V100R001C00

Equipment

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

The BS should be reset to validate the None parameter modification.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The BS should be reset to validate the None parameter modification.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The BS should be reset to validate the None parameter modification.

V100R005C00

Equipment

None

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Equipment

None

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Equipment

None

None

V100R001C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Equipment

None

None

V100R001C00

Equipment

None

None

V100R001C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

None

V100R004C00

Equipment

None

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

None

V100R004C00

Equipment

None

None

V100R004C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R004C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset. The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

None

V100R005C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None None None

N/A N/A N/A N/A

None None None None

V100R003C00 V100R003C00 V100R003C00 V100R003C00

Equipment Equipment Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

This parameter must be consistent with the network plan. Otherwise, the call drop rate The parameter increases and the modification has no access success rate V100R003C00 impact on the decreases for users equipment. at the coverage edge, and the interference on neighboring cells increases. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

This parameter must be consistent with the network The parameter plan. Otherwise, the modification has no call drop rate V100R003C00 impact on the increases and the equipment. access success rate decreases for users at the coverage edge.

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

N/A

V100R004C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R004C00

Equipment

None

V100R004C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R004C00

Equipment

None

V100R004C00

Equipment

None

V100R004C00

Equipment

None

V100R004C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R004C00

Equipment

None

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

The modification of priorities will affect the selection order if the clock source is selected automatically by the system.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

The modification of priorities will affect the selection order when the clock source is selected automatically by the system.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R001C01

Equipment

Only the TOD clock of input type can N/A serve as a clock source.

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

The clock accuracy is affected if there is an excessively large difference (about 20 m) between the value of this parameter and the actual feeder length.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

The modification of priorities will affect the selection order when the clock source is selected automatically by the system.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no impact on the equipment.

This parameter must be consistent with the network V100R001C01 plan. Otherwise, the location precision decreases.

Equipment

None

The parameter modification has no impact on the equipment.

This parameter must be consistent with the network V100R001C01 plan. Otherwise, the location precision decreases.

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

N/A

The feeder delay should be calculated according to the actual length of the feeder. Typically, 3.8 ns delay is generated when data passes one meter feeder. For an LTE TDD cell whose radius is less V100R001C01 than 3 km, the delay must be less then 3 us; for an LTE TDD cell whose radius is greater than 3 km, the delay must be less than 5 us. Otherwise, the service performance is affected. V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

Equipment

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

The clock accuracy is affected if there is an excessively large difference (no less than 20 m) between the value of this parameter and the actual feeder length.

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

When the clock source is selected automatically by the system, the modification of priorities will affect the selection order.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

The parameter should be consistent with N/A configuration of the server domain.

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

N/A

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

The modification of priorities will affect the selection order when the clock source is selected automatically by the system.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

The modification of priorities will affect the selection order when the clock source is selected automatically by the system.

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

N/A

None

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C01

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R001C01

Equipment

N/A

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification takes effect after the None board is automatically reset.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None None None

N/A N/A N/A

None None None

V100R002C00 V100R002C00 V100R002C00

Equipment Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A N/A

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

The start time should be earlier than the end time. If the start time is not specified, the default start time, namely 2000-01-01 00:00:00, is used.

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

The end time should be later than the start time. If the end time is not specified, the default end time, namely 2037-12-31 23:59:59, is used.

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

If the manager is not specified, the EMU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the manager is not specified, the EMU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the actual connection is inconsistent with the configuration, the EMU cannot be maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

The communication address of the EMU is usually 2. If it is not 2, set it according to the physical DIP switch settings.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None None

N/A N/A

None None

V100R001C00 V100R001C00

Equipment Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

If the manager is not specified, the FMU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the manager is not specified, the FMU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

The communication address of the FMU is usually 14. If it is not 14, set it according to the settings of physical DIP switch. Otherwise, the communication with the FMU fails.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

The FMU cannot be operated or maintained if no manager is specified.

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

If the manager is not specified, the TCU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the manager is not specified, the TCU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the actual connection is inconsistent with the data configuration, the TCU cannot be maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

The communication address of the TCU is usually 7. If it is not 7, set it according to the physical DIP switch settings.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R001C00

Equipment Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

If the manager is not specified, the PMU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the manager is not specified, the PMU cannot be operated or maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

If the actual connection is inconsistent with the data configuration, the PMU cannot be maintained.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

The communication address must be consistent with the DIP switch settings on the PMU. Otherwise, the communication fails.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R001C00 V100R001C00

Equipment Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

The INSTALLTYPE of the SC48200 PMU is set to OUTER only. Do not modify it.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

The battery of the SC48200 PMU is not related to this parameter. Do not modify it.

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

V100R001C00

Equipment

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

N/A

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

N/A

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

V100R001C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Equipment

N/A N/A

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A N/A

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R001C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None

N/A N/A

None None

V100R003C00 V100R003C00

Equipment Equipment

None

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None None

N/A N/A

None None

V100R002C00 V100R002C00

Equipment Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

If this parameter is modified, the cells carried by the RRUs behind the breakpoint on the RRU chain become unavailable. The cells carried by the RRUs between breakpoints 1 and 2 on the RRU ring become unavailable.

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R005C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None None None

N/A N/A N/A

None None None

V100R003C00 V100R003C00 V100R003C00

Equipment Equipment Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R005C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment. N/A None

V100R001C00

Equipment

None

V100R002C00

Equipment

None

N/A

None

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R002C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

N/A

None

V100R001C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R001C00

Equipment

N/A

N/A

None

V100R003C00

Equipment

None

N/A

None

V100R003C00

Equipment

None

The parameter modification has no None impact on the equipment.

V100R003C00

Equipment

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R004C00

Radio

None

N/A

None

V100R004C00

Radio

None

N/A

None

V100R004C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

The absolute priorities of frequencies in one system used for cell reselection must be all higher than or lower than the priorities of frequencies in another system. Overlaps between priority ranges are not allowed. It is recommended that priority values be reserved for various systems to prevent overlaps between priority ranges for the systems.

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

None

A bearer of QCI 5 carries IMS signaling that is generally transmitted together with service data. It is recommended that the ServiceIfHoCfgGrou p MO has the same configuration for QCI 5 and the QCI of the coThe parameter transmitted service modification has no data. V100R005C00 impact on the It is also equipment. recommended that QCIs of default bearers be configured to prohibit handovers. If QCIs of default bearers are configured to allow handovers, the UE is immediately handed over to the target frequency after accessing the network.

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

If the values of CounterCheckTimer and CounterCheckCoun tNum are too small, the counter check procedures are performed too frequently, which The parameter wastes radio modification has no interface resources. V100R001C01 impact on the If the values are too equipment. large, the counter check procedure fails to be initiated during a long time, which results in the failure to check the HFN on the UE side and that on the eNodeB side. If the values of CounterCheckTimer and CounterCheckCoun tNum are too small, the counter check procedures are performed too frequently, which The parameter wastes radio modification has no interface resources. V100R001C01 impact on the If the values are too equipment. large, the counter check procedure fails to be initiated during a long time, which causes the failure to check the HFN on the UE side and that on the eNodeB side.

Radio

None

Radio

None

If this switch is set to ON, a DRB is released when the counter check detects an The parameter unexpected result in modification has no the DRB. If this V100R001C01 impact on the switch is set to equipment. OFF, a DRB is not released even if the counter check detects an unexpected result in the DRB.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The setting of this parameter has an impact on how long the eNodeB will wait for a response message from the MME. If this parameter is set to an extremely small value, the eNodeB waits for a period shorter than the transmission time required by a The parameter response message modification has no from the MME. If V100R005C00 impact on the this parameter is set equipment. to an extremely large value, the eNodeB continues waiting for a response message from the MME when it cannot receive the response message due to a fault. As a result, resources are wasted. To prevent this problem, you are advised to retain the default value.

Radio

None

The setting of this parameter has an impact on how long the eNodeB will wait for a response message over the X2 interface from a peer eNodeB. If this parameter is set to an extremely small value, the eNodeB waits for a period shorter than the transmission time required by a The parameter response message modification has no from the peer V100R005C00 impact on the eNodeB. If this equipment. parameter is set to an extremely large value, the eNodeB continues waiting for a response message from the peer eNodeB when it cannot receive the response message due to a fault. As a result, resources are wasted. To prevent this problem, you are advised to retain the default value.

Radio

None

The setting of this parameter has an impact on how long the eNodeB will wait for a response message from a UE. If this parameter is set to an extremely small value, the eNodeB waits for a period shorter than the transmission time required by a The parameter response message modification has no from the UE. If this V100R005C00 impact on the parameter is set to equipment. an extremely large value, the eNodeB continues waiting for a response message from the UE when it cannot receive the response message due to a fault. As a result, resources are wasted. To prevent this problem, you are advised to retain the default value.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no none impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no none impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no impact on the equipment.

If SRI adaptation is enabled, the SRI V100R003C00 load in a cell is increased.

Radio

None

If this parameter is set to LCG_PROFILE_1, non-GBR services are classified into high- and lowThe parameter priority non-GBR modification has no services. QoS of V100R003C00 impact on the high-priority nonequipment. GBR services is better ensured, but there is a risk of failure to maintain QoS of low-priority non-GBR services.

Radio

None

The parameter modification has no none impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no none impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no none impact on the equipment.

V100R005C00

Radio

None

ROHC helps reduce header overhead. The parameter The reduction is modification has no especially V100R003C00 impact on the significant for equipment. services with small data packets, such as VoIP services.

Radio

None

Packet transmission The parameter reliability and the modification has no network link V100R001C01 impact on the overhead are equipment. affected.

Radio

None

The parameter The support for modification has no different protocols is V100R001C01 impact on the affected. equipment.

Radio

None

If this parameter is set to a small value, the eNodeB rejects access of the UE again for the same The parameter reason. If this modification has no parameter is set to V100R001C00 impact on the a large value, the equipment. UE cannot access the network for a long period of time, which affects user experience.

Radio

None

After T320 expires, the dedicated priorities indicated in the RRCConnectionRel ease message become invalid, and the absolute priorities indicated in the system information take effect. As the absolute priorities in the system The parameter information are modification has no optional, frequency V100R002C00 impact on the prioritization can be equipment. better guaranteed during cell reselection if the dedicated priorities are used. If the value of this parameter is too large, cell reselection parameters cannot be updated in time at the UE when priority values change.

Radio

None

If the UE does not complete an intraRAT handover before this timer The parameter expires, the UE modification has no reverts back to the impact on the associated equipment. configuration and initiates an RRC connection reestablishment procedure.

V100R001C00

Radio

None

If the UE does not complete an interRAT handover to GERAN before this The parameter timer expires, the modification has no UE reverts back to V100R001C00 impact on the the associated equipment. configuration and initiates an RRC connection reestablishment procedure.

Radio

None

After T320 expires, the dedicated priorities indicated in the RRCConnectionRel ease message become invalid, and the absolute priorities indicated in the system information take effect. As the absolute priorities in the system The parameter information are modification has no optional, frequency V100R002C00 impact on the prioritization can be equipment. better guaranteed during cell reselection if the dedicated priorities are used. If the value of this parameter is too large, cell reselection parameters cannot be updated in time at the UE when priority values change.

Radio

None

When the UE inactivity timer is turned off, the UE remains connected to the network even if it is in idle mode for a long period of time. When the timer is turned on, the radio resources for the UE are released if it is in The parameter idle mode for a modification has no duration exceeding V100R001C00 impact on the the length of this equipment. timer. If this parameter is set to a small value, the eNodeB releases the connection of a UE before the UE successfully accesses the network. To prevent this problem, you are advised to retain the default value.

Radio

None

If this parameter is set to a large value, a UE cannot enter an out-ofsynchronization state in a timely manner. As a result, the UE unnecessarily occupies PUCCH and SRS resources and the UE power consumption The parameter increases. If this modification has no parameter is set to V100R005C00 impact on the a small value, there equipment. is a probability that the UE enters an out-ofsynchronization state when it should not. As a result, the number of random access times for maintaining uplink synchronization increases and more resources for random access are used.

Radio

None

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R002C00

Radio

None

If this switch is on, The parameter the PA is adjusted. modification has no If this switch is off, impact on the the PA is not equipment. adjusted.

V100R002C00

Radio

None

If the RS power is fixed, setting this parameter to a large value increases the power and MCS of all users in the cell, but results in power The parameter limitation. The modification has no power limitation V100R002C00 impact on the reduces the UE equipment. throughput. Setting this parameter to a small value decreases the power and MCS and reduces the cell throughput.

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

none

V100R001C01

Radio

None

When Ks is equal to 0, the transmit power can be adjusted according to only closed-loop TPC commands. When Ks is equal to 1.25, the transmit The parameter power can be modification has no adjusted by means V100R001C01 impact on the of selecting different equipment. MCSs during scheduling. This helps the UE to quickly adapt to changes in channel conditions and increases the cell throughput.

Radio

None

If the value of this parameter is too small, the transmit power of the SRS is too low, so that the uplink timing requirement is not met and the SINR of data channels cannot be measured accurately. Thus, The parameter the network modification has no performance V100R001C01 impact on the deteriorates. If the equipment. value of this parameter is too large, the transmit power of the SRS is excessively high, which increases the interference to other channels and neighboring cells and thus reduces the throughput of the entire network.

Radio

None

If the value of this parameter is too small, the transmit power of the SRS is too low, so that the uplink timing requirement is not met and the SINR of data channels cannot be measured accurately. Thus, The parameter the network modification has no performance V100R001C01 impact on the deteriorates. If the equipment. value of this parameter is too large, the transmit power of the SRS is excessively high, which increases the interference to other channels and neighboring cells and thus reduces the throughput of the entire network.

Radio

None

A greater value of this parameter indicates a smaller impact of the previous RSRP value on the filtered value and a greater impact of the RSRP value measured this The parameter time on the filtered modification has no value. A smaller V100R001C01 impact on the value of this equipment. parameter indicates a greater impact of the previous RSRP value on the filtered value and a smaller impact of the RSRP value measured this time on the filtered value.

Radio

None

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

An appropriate value of this parameter effectively reduces the probability of cross-cell handovers and The parameter therefore increases modification has no the handover V100R005C00 impact on the success rate. A equipment. smaller value of this parameter results in a higher probability of distance-based handovers. A larger value of this parameter results in the opposite effect.

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

DRX introduces extra delay to scheduling. Therefore, if a UE with a service whose QCI is mapped to a high requirement for the delay is allowed to enter the DRX The parameter state, the QoS modification has no satisfaction rate V100R003C00 impact on the decreases because equipment. of the increase in the delay of the service. If a UE with a service whose QCI is mapped to a low requirement for the delay is not allowed to enter the DRX state, it is not power-saving for the UE.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

If this parameter is set to a small value, the UE enters Sleep Time before receiving the retransmitted data, resulting in failures to correctly receive The parameter the retransmitted modification has no data. If this V100R003C00 impact on the parameter is set to equipment. a large value, the UE keeps waiting even when retransmitted data is lost. That is, the UE stays active, which is not powersaving.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The entering condition of event A1 is as follows: Ms - Hys > Thresh. The triggering condition of event A2 is as follows: Ms + Hys < Thresh. Ms is the measurement value of the serving cell, The parameter Hys is the modification has no hysteresis for event V100R003C00 impact on the A1 or A2 contained equipment. in the measurement configuration, and Thresh is the threshold for the particular event. A larger value of Hys results in a lower probability of triggering event A1 or A2.

Radio

None

The time-to-trigger helps reduce the number of interRAT measurements and prevent unnecessary interRAT The parameter measurements. The modification has no larger the value of V100R003C00 impact on the this parameter, the equipment. smaller the average number of interRAT measurements, and the higher the probability of call drops.

Radio

None

The entering condition of event A1 is as follows: Ms - Hys > Thresh. A larger value of Thresh results in a The parameter lower probability of modification has no triggering event A1 V100R003C00 impact on the and therefore a equipment. lower probability of stopping inter-RAT measurements. A smaller value of Thresh leads to a higher probability.

Radio

None

None

None

The entering condition of event A1 is as follows: Ms - Hys > Thresh. Thresh is the threshold for this event. A larger The parameter value of Thresh modification has no results in a lower V100R003C00 impact on the probability of equipment. triggering event A1 and therefore a lower probability of stopping inter-RAT measurements. A smaller value of Thresh leads to a higher probability. The entering condition of event A2 is as follows: Ms + Hys < Thresh. Thresh is the threshold for this event. A larger The parameter value of Thresh modification has no results in a higher V100R003C00 impact on the probability of equipment. triggering event A2 and therefore a higher probability of starting inter-RAT measurements. A smaller value of Thresh leads to a lower probability. The entering condition of event A2 is as follows: Ms + Hys < Thresh. Thresh is the threshold for this event. A larger The parameter value of Thresh modification has no results in a higher V100R003C00 impact on the probability of equipment. triggering event A2 and therefore a higher probability of starting inter-RAT measurements. A smaller value of Thresh leads to a lower probability.

Radio

Radio

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Mn is the measurement value of the neighboring cell. Ofn is the frequency-specific offset of the neighboring cell. Thresh is the threshold for event B1. Hys is the The parameter hysteresis for event modification has no B1. V100R003C00 impact on the A larger value of equipment. Hys results in a lower probability of triggering event B1 and hence causes a lower probability of handover. A large value may affect user experience. A smaller value of Hys leads to a higher probability of triggering event B1. A small value may cause handover decision errors and ping-pong

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the CDMA2000 1xRTT equipment. cell, and a smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the CDMA2000 1xRTT equipment. cell, and a smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the CDMA2000 1xRTT equipment. cell, and a smaller value leads to a higher probability.

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

A larger value of this parameter results in a longer average SRI period for UEs in a cell and a larger capacity of SRI users in the The parameter cell, but it also lead modification has no to a longer average V100R003C00 impact on the delay of uplink equipment. scheduling for UEs in the cell. A smaller value of this parameter results in a smaller capacity of SRI users in a cell.

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Mn is the measurement value of the neighboring cell. Ofn is the frequency-specific offset of the neighboring cell. Thresh is the threshold for this event. Hys is the The parameter hysteresis for this modification has no event, which is used V100R003C00 impact on the to prevent frequent equipment. triggering of event evaluation caused by radio signal fluctuation or fading. A larger value of Hys results in a lower probability of triggering event B1 and hence causes a lower probability of handover. A large value may affect user experience. A smaller value of Hys leads to a higher probability of

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the impact on the CDMA2000 HRPD equipment. cell, and a smaller value leads to a higher probability.

V100R003C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the impact on the CDMA2000 HRPD equipment. cell, and a smaller value leads to a higher probability.

V100R003C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the impact on the CDMA2000 HRPD equipment. cell, and a smaller value leads to a higher probability.

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Mn is the measurement value of the neighboring cell. Ofn is the frequency-specific offset of the neighboring cell. Thresh is the threshold for event B1. Hys is the The parameter hysteresis for event modification has no B1. V100R003C00 impact on the A larger value of equipment. Hys results in a lower probability of triggering event B1 and therefore a lower probability of handover. A large value may affect user experience. A smaller value of Hys leads to a higher probability of triggering event B1. A small value may cause handover decision errors and ping-pong

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the GERAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the GERAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the GERAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R003C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the UTRAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the UTRAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Mn is the measurement value of the neighboring cell. Ofn is the frequency-specific offset of the neighboring cell. Thresh is the threshold for event B1. Hys is the The parameter hysteresis for event modification has no B1. V100R003C00 impact on the A larger value of equipment. Hys results in a lower probability of triggering event B1 and therefore a lower probability of handover. A large value may affect user experience. A smaller value of Hys leads to a higher probability of triggering event B1. A small value may cause handover decision errors and ping-pong

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the UTRAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the UTRAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R003C00 impact on the UTRAN cell, and a equipment. smaller value leads to a higher probability.

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The triggering condition of event A1 is as follows: Ms - Hys > Thresh. The triggering condition of event A2 is as follows: Ms + Hys < Thresh. Ms is the measurement value The parameter of the serving cell, modification has no Hys is the V100R003C00 impact on the hysteresis for event equipment. A1 or A2 contained in the measurement configuration, and Thresh is the threshold for the particular event. A larger value of Hys results in a lower probability of triggering event A1 or A2.

Radio

None

The time-to-trigger helps reduce the number of interfrequency measurements and prevent unnecessary interThe parameter frequency modification has no measurements. The V100R003C00 impact on the larger the value of equipment. this parameter, the smaller the average number of interfrequency measurements, and the higher the probability of call drops.

Radio

None

The entering condition of event A1 is as follows: Ms - Hys > Thresh. Thresh is the threshold for the event. A larger value of Thresh The parameter results in a lower modification has no probability of V100R003C00 impact on the triggering event A1 equipment. and hence causes a lower probability of stopping interfrequency measurements. A smaller value of Thresh leads to a higher probability.

Radio

None

The entering condition of event A1 is as follows: Ms - Hys > Thresh. Thresh is the threshold for the event. A larger value of Thresh The parameter results in a lower modification has no probability of V100R003C00 impact on the triggering event A1 equipment. and hence causes a lower probability of stopping interfrequency measurements. A smaller value of Thresh leads to a higher probability. The entering condition of event A2 is as follows: Ms + Hys < Thresh. Thresh is the threshold for the event. A smaller value of Thresh The parameter results in a lower modification has no probability of V100R003C00 impact on the triggering event A2 equipment. and hence causes a lower probability of starting interfrequency measurements. A larger value of Thresh leads to a higher probability.

Radio

None

Radio

None

The entering condition of event A2 is as follows: Ms + Hys < Thresh. Thresh is the threshold for the event. A smaller value of Thresh The parameter results in a lower modification has no probability of V100R003C00 impact on the triggering event A2 equipment. and hence causes a lower probability of starting interfrequency measurements. A larger value of Thresh leads to a higher probability. A larger value of this parameter results in a lower probability of triggering event A4 and hence causes a lower probability of handover. A large The parameter value may affect modification has no user experience. A V100R003C00 impact on the smaller value of this equipment. parameter leads to a higher probability of triggering event A4. A small value may cause handover decision errors and pingpong handovers.

Radio

None

Radio

None

A larger value of this parameter results in a lower probability of triggering event A4 and hence causes a lower probability of handover. A large The parameter value may affect modification has no user experience. A V100R003C00 impact on the smaller value of this equipment. parameter leads to a higher probability of triggering event A4. A small value may cause handover decision errors and pingpong handovers. A larger value of this parameter results in a lower probability of triggering event A4 and hence causes a lower probability of handover. A large The parameter value may affect modification has no user experience. A V100R003C00 impact on the smaller value of this equipment. parameter leads to a higher probability of triggering event A4. A small value may cause handover decision errors and pingpong handovers.

Radio

None

Radio

None

A larger value of this parameter results in a lower probability of handover to an interThe parameter frequency cell, a modification has no smaller average V100R003C00 impact on the number of equipment. handovers, and a higher call drop rate. A smaller value of this parameter leads to the opposite effect.

Radio

None

A larger value of this parameter results in a lower probability of triggering event A4 and hence causes a lower probability of handover. A large The parameter value may affect modification has no user experience. A V100R003C00 impact on the smaller value of this equipment. parameter leads to a higher probability of triggering event A4. A small value may cause handover decision errors and pingpong handovers.

Radio

None

A larger value of this parameter results in a lower probability of triggering event A4 and hence causes a lower probability of handover. A large The parameter value may affect modification has no user experience. A V100R003C00 impact on the smaller value of this equipment. parameter leads to a higher probability of triggering event A4. A small value may cause handover decision errors and pingpong handovers.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

A larger value of this parameter results in a lower probability of triggering event A3 and therefore a The parameter lower probability of modification has no handover. A smaller V100R003C00 impact on the value of this equipment. parameter leads to a higher probability of triggering event A3 and therefore a higher probability of handover.

Radio

None

The entering condition of event A1 is as follows: Ms - Hys > Thresh. Thresh is the threshold for the event. A large value The parameter of Thresh results in modification has no a low probability of V100R003C00 impact on the triggering event A1 equipment. and hence causes a low probability of stopping interfrequency measurements. A small value of Thresh leads to a high probability. The entering condition of event A2 is as follows: Ms + Hys < Thresh. Thresh is the threshold for the event. A small value The parameter of Thresh results in modification has no a low probability of V100R003C00 impact on the triggering event A2 equipment. and hence causes a low probability of starting interfrequency measurements. A large value of Thresh leads to a high probability.

Radio

None

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

A larger value of this parameter results in a lower probability of triggering event A3 and hence causes a lower probability of handover. A large The parameter value may affect modification has no user experience. A V100R003C00 impact on the smaller value of this equipment. parameter leads to a higher probability of triggering event A3. A small value may cause handover decision errors and pingpong handovers.

Radio

None

A positive value of this parameter results in a relatively low probability of triggering event A3 and therefore a relatively low The parameter probability of modification has no handover. A V100R003C00 impact on the negative value of equipment. this parameter leads to a relatively high probability of triggering event A3 and therefore a relatively high probability of handover.

Radio

None

This parameter helps reduce the average number of handovers and the number of unexpected handovers, and The parameter hence prevents modification has no unnecessary V100R003C00 impact on the handovers. A larger equipment. value of this parameter results in a smaller average number of handovers, but it also leads to a higher risk of call drops.

Radio

None

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The BS should be reset to validate the None parameter modification.

V100R002C00

Radio

None

The BS should be reset to validate the None parameter modification.

V100R003C00

Radio

None

The BS should be reset to validate the None parameter modification.

V100R003C00

Radio

None

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The BS should be reset to validate the None parameter modification.

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

The link should be reestablished after the parameter modification.

None

V100R005C00

Radio

None

The link should be reestablished after the parameter modification.

None

V100R002C00

Radio

None

The link should be reestablished after the parameter modification.

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R004C00

Radio

None

N/A

None

V100R004C00

Radio

None

N/A

None

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

N/A

None

V100R001C00

Radio

None

The link should be reestablished after the parameter modification. The link should be reestablished after the parameter modification. The link should be reestablished after the parameter modification.

None

V100R005C00

Radio

None

None

V100R002C00

Radio

None

None

V100R003C00

Radio

None

This parameter has an impact on The parameter automatic removal modification has no of the X2 interface V100R001C01 impact on the in a situation where equipment. the peer eNodeB is removed.

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R004C00

Radio

None

If this parameter is set to ON, the UE may enter the DRX The parameter state, saving UE modification has no power. If this V100R001C01 impact on the parameter is set to equipment. OFF, the UE consumes relatively much power. The parameter modification has no impact on the equipment. This parameter has little impact on the radio network V100R001C01 performance. Short DRX cycles reduce the traffic delay.

Radio

None

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R002C00

Radio

None

IMS signaling and low-delay services are prioritized during scheduling but consume many resources to ensure The parameter their QoS. modification has no Therefore, it is V100R002C00 impact on the recommended that equipment. this parameter not be set to IMSSignalling or LowDelay for TCP services and nonreal-time streaming services. This parameter has an impact on the The parameter throughput and the modification has no QoS differentiation V100R001C00 impact on the service. Its value is equipment. subject to the operator's policy. This parameter has an impact on the The parameter throughput and the modification has no QoS differentiation V100R001C00 impact on the service. Its value is equipment. subject to the operator's policy.

Radio

None

Radio

None

Radio

None

If this parameter is set to a large value, the Min_GBR (minimum guaranteed bit rate) of high-priority nonGBR services can be guaranteed but the Min_GBR of lowpriority non-GBR The parameter services cannot be modification has no guaranteed when V100R002C00 impact on the resources are equipment. insufficient. If this parameter is set to a small value, there is an impact on the response time of non-GBR services when resources are insufficient and there are higherpriority services. If this parameter is set to a large value, the Min_GBR (minimum guaranteed bit rate) of high-priority nonGBR services can be guaranteed but the Min_GBR of lowpriority non-GBR The parameter services cannot be modification has no guaranteed when V100R002C00 impact on the resources are equipment. insufficient. If this parameter is set to a small value, there is an impact on the response time of non-GBR services when resources are insufficient and there are higherpriority services.

Radio

None

Radio

None

This parameter affects the preallocation probability of its The parameter corresponding type modification has no of service and V100R002C00 impact on the therefore affects the equipment. service delay. The delay has a negative correlation with the preallocation weight.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

If this parameter is set to PBR_0_KBps, there is a risk that the corresponding services will never be scheduled. If this The parameter parameter is set to modification has no PBR_INFINITY and V100R003C00 impact on the the corresponding equipment. traffic volume is high, there is a risk that the services with QCIs indicating lower priorities than this QCI will never be scheduled.

Radio

None

Services with The parameter relatively high modification has no priorities are impact on the scheduled equipment. preferentially.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R003C00

Radio

None

If this parameter is set to The parameter REDIRECTION for modification has no a bearer with a QCI V100R003C00 impact on the of 1, call drop equipment. occurs during a redirection.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

If this parameter is set to The parameter REDIRECTION for modification has no a bearer with a QCI V100R003C00 impact on the of 1, call drop equipment. occurs during a redirection.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R003C00

Radio

None

A large value of this parameter results in a long delay of services and a failure to meet the The parameter QCI requirement. A modification has no small value of this V100R003C00 impact on the parameter leads to equipment. a severe case of PDCP data discarding and therefore low throughput.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

A larger value of this parameter leads to a higher interference resistance capability, but a larger number of retransmissions results in a longer delay and lower throughput. Set this parameter to a small value for services with a high requirement for the The parameter delay and to a large modification has no value for services V100R003C00 impact on the with a low equipment. requirement for the delay. RRC connection reestablishment has a great impact on Acknowledged Mode (AM) services, such as packet-losssensitive and delayinsensitive TCP services, because packets in the buffer are discarded upon the reestablishment.

Radio

None

A larger value of this parameter leads to a higher interference resistance capability, but a larger number of retransmissions results in a longer delay and lower throughput. Set this parameter to a small value for services with a high requirement for the The parameter delay and to a large modification has no value for services V100R003C00 impact on the with a low equipment. requirement for the delay. RRC connection reestablishment has a great impact on Acknowledged Mode (AM) services, such as packet-losssensitive and delayinsensitive TCP services, because packets in the buffer are discarded upon the reestablishment.

Radio

None

To prevent buffer overflow caused by an excessively long queue, the transmitter sends status reports based on the data volume of The parameter transmitted PDUs. modification has no A small value of this V100R003C00 impact on the parameter results in equipment. a low frequency of sending polling PDUs. A large value leads to high buffer occupancy and a slow speed of send window movement.

Radio

None

To prevent buffer overflow caused by an excessively long queue, the transmitter sends status reports based on the data volume of The parameter transmitted PDUs. modification has no A small value of this V100R003C00 impact on the parameter results in equipment. a low frequency of sending polling PDUs. A large value leads to high buffer occupancy and a slow speed of send window movement.

Radio

None

To prevent the send window from changing to 0, the transmitter initiates status reporting based on the number of PDUs. A small value (smaller than or equal to PollPdu_p16) of this parameter results in a high frequency of sending polling PDUs, a short The parameter round-trip time for modification has no RLC packets, and a V100R003C00 impact on the high speed of send equipment. window movement. If the send window is not 0, however, a small value does not increase the transmission speed; instead, it leads to an excessive number of status reports. A large value of this parameter results in a low speed of send window movement.

Radio

None

To prevent the send window from changing to 0, the transmitter initiates status reporting based on the number of PDUs. A small value (smaller than or equal to PollPdu_p16) of this parameter results in a high frequency of sending polling PDUs, a short The parameter round-trip time for modification has no RLC packets, and a V100R003C00 impact on the high speed of send equipment. window movement. If the send window is not 0, however, a small value does not increase the transmission speed; instead, it leads to an excessive number of status reports. A large value of this parameter results in a low speed of send window movement.

Radio

None

If this parameter is set to a small value, too many polling PDUs are sent. In addition, the number of ARQ retransmissions reaches its The parameter maximum due to modification has no consecutive PDU V100R003C00 impact on the retransmissions, equipment. and therefore the RRC connection is re-established. If this parameter is set to a large value, status reports cannot be sent in time.

Radio

None

If this parameter is set to a small value, too many polling PDUs are sent. In addition, the number of ARQ retransmissions reaches its The parameter maximum due to modification has no consecutive PDU V100R003C00 impact on the retransmissions, equipment. and therefore the RRC connection is re-established. If this parameter is set to a large value, status reports cannot be sent in time.

Radio

None

This parameter has an impact on status reporting in AM. A low frequency of status reporting leads to a low frequency of status report scheduling but a high probability that the send window changes to 0 at the transmitter, thereby reducing the transmission rate. A The parameter high frequency of modification has no status reporting V100R003C00 impact on the leads to a high equipment. probability of timely acknowledgment to data in the send window and therefore a high probability of rate guarantee. However, a high frequency of status reporting results in a high probability of status report scheduling and repeated transmissions, thereby wasting

Radio

None

This parameter has an impact on status reporting in AM. A low frequency of status reporting leads to a low frequency of status report scheduling but a high probability that the send window changes to 0 at the transmitter, thereby reducing the transmission rate. A The parameter high frequency of modification has no status reporting V100R003C00 impact on the leads to a high equipment. probability of timely acknowledgment to data in the send window and therefore a high probability of rate guarantee. However, a high frequency of status reporting results in a high probability of status report scheduling and repeated transmissions, thereby wasting

Radio

None

A small value of this parameter results in useless HARQ retransmissions from the transmitter and repeated status reports from the receiver, thereby wasting resources. A large value of this The parameter parameter leads to modification has no a long delay for the V100R003C00 impact on the receiver to equipment. determine an out-oforder packet transmission failure and therefore a long delay for sending status reports, thereby delaying services and reducing the throughput.

Radio

None

A small value of this parameter results in useless HARQ retransmissions from the transmitter and repeated status reports from the receiver, thereby wasting resources. A large value of this The parameter parameter leads to modification has no a long delay for the V100R003C00 impact on the receiver to equipment. determine an out-oforder packet transmission failure and therefore a long delay for sending status reports, thereby delaying services and reducing the throughput.

Radio

None

The PDCP sequence number size must be large enough to prevent Hyper Frame Number (HFN) The parameter mismatch caused modification has no by loss of a large V100R003C00 impact on the number of packets. equipment. However, a longer PDCP sequence number results in more PDCP header overhead and lower payload throughput.

Radio

None

The sequence number size specified by this parameter must be large enough to The parameter prevent sequence modification has no number ambiguity impact on the caused by HARQ equipment. retransmissions. However, a large size results in a heavy RLC header load. The sequence number size specified by this parameter must be large enough to The parameter prevent sequence modification has no number ambiguity impact on the caused by HARQ equipment. retransmissions. However, a large size results in a heavy RLC header load.

V100R003C00

Radio

None

V100R003C00

Radio

None

A small value of this parameter results in useless HARQ retransmissions from the transmitter and a large number of lost packets. A The parameter large value of this modification has no parameter leads to V100R003C00 impact on the a long delay for the equipment. receiver to determine an out-oforder packet transmission failure, thereby delaying services and reducing the throughput.

Radio

None

A small value of this parameter results in useless HARQ retransmissions from the transmitter and a large number of lost packets. A The parameter large value of this modification has no parameter leads to V100R003C00 impact on the a long delay for the equipment. receiver to determine an out-oforder packet transmission failure, thereby delaying services and reducing the throughput.

Radio

None

If this parameter is set to FALSE, the target eNodeB will transmit all data The parameter forwarded by the modification has no source eNodeB. V100R003C00 impact on the Part of the data may equipment. already be transmitted to UEs, thereby wasting resources on the air interface.

Radio

None

N/A

None

V100R003C00

Radio

None

This parameter has an impact on the The parameter throughput and the modification has no QoS differentiation V100R003C00 impact on the service. Its value is equipment. subject to the operator's policy. This parameter has an impact on the The parameter throughput and the modification has no QoS differentiation V100R003C00 impact on the service. Its value is equipment. subject to the operator's policy.

Radio

None

Radio

None

If this parameter is set to a large value, the Min_GBR (minimum guaranteed bit rate) of high-priority nonGBR services can be guaranteed but the Min_GBR of lowpriority non-GBR The parameter services cannot be modification has no guaranteed when V100R003C00 impact on the resources are equipment. insufficient. If this parameter is set to a small value, there is an impact on the response time of non-GBR services when resources are insufficient and there are higherpriority services. If this parameter is set to a large value, the Min_GBR (minimum guaranteed bit rate) of high-priority nonGBR services can be guaranteed but the Min_GBR of lowpriority non-GBR The parameter services cannot be modification has no guaranteed when V100R003C00 impact on the resources are equipment. insufficient. If this parameter is set to a small value, there is an impact on the response time of non-GBR services when resources are insufficient and there are higherpriority services.

Radio

None

Radio

None

This parameter affects the preallocation probability of its The parameter corresponding type modification has no of service and V100R003C00 impact on the therefore affects the equipment. service delay. The delay has a negative correlation with the preallocation weight.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

If this parameter is set to PBR_0_KBps, there is a risk that the corresponding services will never be scheduled. If this The parameter parameter is set to modification has no PBR_INFINITY and V100R003C00 impact on the the corresponding equipment. traffic volume is high, there is a risk that the services with QCIs indicating lower priorities than this QCI will never be scheduled.

Radio

None

Services with The parameter relatively high modification has no priorities are impact on the preferentially equipment. scheduled.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

This parameter and other associated factors have an impact on the CQI reporting mode and The parameter reporting modification has no parameters, and V100R003C00 impact on the therefore affect the equipment. feedback overhead in the uplink and throughput or coverage in the downlink.

Radio

None

The setting of this parameter determines the transmission modes The parameter that apply to UEs modification has no served by a multiV100R003C00 impact on the antenna eNodeB equipment. and therefore affects performance such as the throughput and coverage.

Radio

None

The setting of this parameter determines the transmission modes The parameter that apply to UEs modification has no served by a multiV100R003C00 impact on the antenna eNodeB equipment. and therefore affects performance such as the throughput and coverage.

Radio

None

The setting of this parameter determines the The parameter configuration of the modification has no CQI reporting V100R005C00 impact on the period, affecting the equipment. UE throughput and number of UEs supported by a cell.

Radio

None

When CqiPeriodAdaptive is set to OFF, the setting of this parameter determines the CQI The parameter period. A smaller modification has no value of this V100R005C00 impact on the parameter results in equipment. high UE throughput but fewer UEs that can participate in CQI reporting. A larger value of this parameter results in the opposite effect.

Radio

None

The setting of this parameter determines the transmission modes The parameter that apply to UEs modification has no served by a multiV100R001C01 impact on the antenna eNodeB equipment. and therefore affects performance such as the throughput and coverage.

Radio

None

The setting of this parameter determines the transmission modes The parameter that apply to UEs modification has no served by a multiV100R003C00 impact on the antenna eNodeB equipment. and therefore affects performance such as the throughput and coverage.

Radio

None

This parameter affects the configuration of The parameter SRS periods for modification has no UEs and therefore V100R005C00 impact on the affects the UE equipment. throughput and number of UEs supported by a cell. When SrsPeriodAdaptive is set to OFF, the setting of this parameter determines the SRS The parameter period. A smaller modification has no value of this V100R005C00 impact on the parameter results in equipment. fewer UEs that can participate in SRS reporting. A larger value of this parameter results in the opposite effect.

Radio

None

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A decrease in the value of this parameter indicates a decrease in the number of candidate cells for each handover. In The parameter this case, the modification has no success rate of the V100R001C00 impact on the handover triggered equipment. by each measurement report is decreased, but the required amount of radio interface resource is reduced.

Radio

None

When the value is increased, the number of reports increases and the handover success The parameter rate rises. An modification has no excessively large V100R001C00 impact on the number of reports, equipment. however, results in excessive signaling and hence causes a waste of radio interface resources.

Radio

None

A smaller value of this parameter results in a larger number of reports and greater consumption of radio interface resources. A larger value of this The parameter parameter leads to modification has no a longer delay of V100R001C00 impact on the handover retries equipment. and hence a lower handover success rate. In the early stage of LTE deployment, this parameter should be set to a small value to ensure timely handovers.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a larger number of reports, greater consumption of radio interface The parameter resources and a modification has no higher handover impact on the success rate. A equipment. larger value of this parameter leads to a longer delay of handover retries and thus a lower handover success rate.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a larger number of reports and greater consumption of radio interface resources. A larger value of this The parameter parameter leads to modification has no a longer delay of V100R001C00 impact on the handover retries equipment. and hence a lower handover success rate. In the early stage of LTE deployment, this parameter should be set to a small value to ensure timely handovers.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a larger number of reports and greater consumption of radio interface resources. A larger value of this The parameter parameter leads to modification has no a longer delay of V100R001C00 impact on the handover retries equipment. and hence a lower handover success rate. In the early stage of LTE deployment, this parameter should be set to a small value to ensure timely handovers.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

A decrease in the value of this parameter indicates a decrease in the number of candidate cells for each handover. In The parameter this case, the modification has no success rate of the V100R001C00 impact on the handover triggered equipment. by each measurement report is decreased, but the required amount of radio interface resource is reduced.

Radio

None

When the value is increased, the number of reports increases and the handover success The parameter rate rises. An modification has no excessively large V100R001C00 impact on the number of reports, equipment. however, results in excessive signaling and hence causes a waste of radio interface resources.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a larger number of reports, greater consumption of radio interface The parameter resources and a modification has no higher handover impact on the success rate. A equipment. larger value of this parameter leads to a longer delay of handover retries and therefore a lower handover success rate.

V100R001C00

Radio

None

If this parameter is set to BOTH, both measured RSRP and RSRQ values are reported. In this situation, a handover is triggered only when both the measured values meet the corresponding conditions, The parameter preventing modification has no unnecessary V100R001C00 impact on the handovers. equipment. If this parameter is set to SAME_AS_TRIG_ QUAN, the measurement quantity included in the measurement report for event A4 is the same as the quantity used in the evaluation for the related event A2.

Radio

None

A smaller value of this parameter results in a larger number of reports, greater consumption of radio interface The parameter resources and a modification has no higher handover impact on the success rate. A equipment. larger value of this parameter leads to a longer delay of handover retries and thus a lower handover success rate.

V100R001C00

Radio

None

If this parameter is set to BOTH, the eNodeB sends UEs two measurement configurations for events A1 and A2: one based on RSRP, and the The parameter other based on modification has no RSRQ. When the V100R001C00 impact on the triggering condition equipment. specified by either configuration for event A1 or A2 is fulfilled, the corresponding event is reported and inter-frequency measurements are stopped or started.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R002C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the impact on the UTRAN cell, and a equipment. smaller value results in a higher probability.

V100R002C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R002C00 impact on the GERAN cell, and a equipment. smaller value results in a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to impact on the CDMA2000, and a equipment. smaller value results in a higher probability.

V100R002C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to impact on the UTRAN, and a equipment. smaller value results in a higher probability.

V100R002C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to impact on the UTRAN, and a equipment. smaller value results in a higher probability.

V100R001C00

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to the V100R002C00 impact on the GERAN cell, and a equipment. smaller value results in a higher probability.

Radio

None

A larger value of this parameter results in a lower The parameter probability of modification has no handover to impact on the CDMA2000, and a equipment. smaller value results in a higher probability.

V100R002C00

Radio

None

N/A

None

V100R001C00

Radio

None

If AcBarringForMoDat aCfgInd or AcBarringForMoSig CfgInd in SIB2 is set to CFG, the UE draws a random number 'rand' that is uniformly distributed in the range [0,1). If rand is smaller than the value of AcBarringFactorFor Call or AcBarringFactorFor The parameter Sig, the UE modification has no considers access to V100R001C01 impact on the the cell as allowed. equipment. That is, the RRC connection can be set up for the mobile-originated call or signaling. If AcBarringFactorFor Call or AcBarringFactorFor Sig is set to a large value, the probability of allowing access to the cell is high, which may lead to a high cell load. If AcBarringFactorFor

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

If AcBarringForMoDat aCfgInd in SIB2 is set to CFG, the UE draws a random number 'rand' that is uniformly distributed in the range [0,1). If rand is smaller than the value of this parameter, the UE considers access to the cell as allowed. That is, an RRC connection can be The parameter set up for the modification has no mobile-originated V100R001C00 impact on the call. If this equipment. parameter is set to a large value, the probability of allowing access to the cell is high, which may lead to a high cell load. If this parameter is set to a small value, the probability of allowing access to the cell is low, in which situation UEs may fail to access the cell even when the cell load is

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

If AcBarringForMoDat aCfgInd or AcBarringForMoSig CfgInd in SIB2 is set to CFG, the UE draws a random number 'rand' that is uniformly distributed in the range [0,1). If rand is smaller than the value of this parameter, the UE considers access to the cell as allowed. The parameter That is, the RRC modification has no connection can be V100R001C00 impact on the set up for the equipment. signaling. If this parameter is set to a large value, the probability of allowing access to the cell is high, which may lead to a high cell load. If this parameter is set to a small value, the probability of allowing access to the cell is low, in which situation UEs may fail to access the cell even when

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R001C00

Radio

None

With other cell reselection parameters unchanged, a larger value of this parameter indicates a lower probability of reselection to an The parameter intra-frequency or modification has no same-priority V100R001C00 impact on the neighboring cell, equipment. leading to an increased service drop rate. A smaller value of this parameter indicates a higher probability, leading to a larger number of pingpong cell reselections.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A larger value of this parameter leads to a lower probability of the UE entering the highThe parameter mobility or mediummodification has no mobility state and a V100R001C00 impact on the smaller impact of equipment. the mobility status on cell reselection. A smaller value of this parameter leads to the opposite effect.

Radio

None

A larger value of this parameter leads to a lower probability of the UE entering the normal The parameter mobility state, a modification has no lower probability of V100R001C00 impact on the adjustment of equipment. reselection-related parameters, and a smaller impact of UE speed variation on cell reselection.

Radio

None

A larger value of this parameter indicates a lower probability of a UE entering the medium mobility state. In this case, The parameter the reselectionmodification has no related parameters V100R001C00 impact on the are not adjusted equipment. and cell reselections are more difficult to trigger. A smaller value of this parameter leads to the opposite effect.

Radio

None

A larger value of this parameter indicates a lower probability of a UE entering the high mobility state. In The parameter this case, modification has no reselection-related V100R001C00 impact on the parameters are not equipment. adjusted and cell reselections are more difficult to trigger. A smaller value of this parameter leads to the opposite effect.

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no hysteresis for cell V100R001C00 impact on the reselection, that is, equipment. results in a higher probability of cell reselection. A larger value leads to a smaller impact.

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no hysteresis for cell V100R001C00 impact on the reselection, that is, equipment. results in a higher probability of cell reselection. A larger value leads to a smaller impact.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a higher probability modification has no of triggering interV100R001C00 impact on the frequency or interequipment. RAT measurements, and a smaller value indicates a lower probability.

Radio

None

A smaller value of this parameter The parameter indicates a lower modification has no frequency of the V100R001C00 impact on the reselection to a low equipment. priority interfrequency/inter-RAT cell.

Radio

None

A larger value of this parameter indicates a higher probability of a UE The parameter camping on the modification has no cells assigned with V100R001C00 impact on the the same frequency equipment. as the serving one, and a smaller value indicates a lower probability.

Radio

None

The greater the parameter, the more difficult for the cell to meet the S criterion, the more difficult for the cell to become Suitable Cell. The difficulty level of the cell selection is increased. The The parameter smaller the modification has no parameter, the V100R001C00 impact on the easier for the cell to equipment. meet the S criterion, the easier for the cell to become Suitable Cell. The difficulty level of the cell selection is decreased. The selected cell should provide the signal quality for the basic services.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

With other conditions unchanged, a larger value of this The parameter parameter indicates modification has no a higher probability V100R001C00 impact on the of triggering intraequipment. frequency measurements, and a smaller value indicates a lower probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

When this value is increased, the selection of the intraThe parameter frequency cell modification has no becomes more V100R001C00 impact on the difficult. When the equipment. value is decreased, the selection becomes easier.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no cell reselection V100R001C00 impact on the duration within Eequipment. UTRAN, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

A smaller value of this parameter results in a greater impact of the UE mobility state on the The parameter actual value of the modification has no timer for cell V100R001C00 impact on the reselection within Eequipment. UTRAN, that is, results in a higher probability of cell reselection. A larger value leads to a smaller impact.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

With other conditions unchanged, a larger value of this The parameter parameter indicates modification has no a higher probability V100R004C00 impact on the of triggering intraequipment. frequency measurements, and a smaller value indicates a lower probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a higher probability modification has no of triggering interV100R004C00 impact on the frequency or interequipment. RAT measurements, and a smaller value indicates a lower probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

With other conditions unchanged, a smaller value of this parameter leads to The parameter a lower probability modification has no of reselection to an V100R004C00 impact on the inter-frequency or equipment. inter-RAT cell on lower-priority frequencies, and a larger value of this parameter leads to a higher probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

With other conditions unchanged, a smaller parameter value for a cell leads to lower probabilities of the cell meeting criteria S and becoming a The parameter suitable cell for modification has no selection, and a V100R004C00 impact on the larger parameter equipment. value for a cell leads to higher probabilities. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

When other conditions remain unchanged, an increase in the value of this The parameter parameter results in modification has no a decrease in the V100R001C00 impact on the probability of equipment. reselection to the neighboring cell, and a decrease in the value results in an increase in the probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no duration of cell V100R001C00 impact on the reselection to equipment. CDMA2000 HRPD, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no duration of cell V100R001C00 impact on the reselection to equipment. CDMA2000 HRPD, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no duration of cell V100R001C00 impact on the reselection to equipment. GERAN, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no duration of cell V100R001C00 impact on the reselection to equipment. GERAN, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

N/A

None

V100R001C00

Radio

None

When other conditions remain unchanged, an increase in the value of this The parameter parameter results in modification has no a decrease in the V100R001C00 impact on the probability of equipment. reselection to the neighboring cell, and a decrease in the value results in an increase in the probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no duration of cell V100R001C00 impact on the reselection to equipment. UTRAN, that is, a shorter duration. A larger value leads to a smaller impact.

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no duration of cell V100R001C00 impact on the reselection to equipment. UTRAN, that is, a shorter duration. A larger value leads to a smaller impact.

Radio

None

N/A

None

V100R001C00

Radio

None

A larger value of this parameter leads to a lower probability of the cell meeting criteria S and becoming a suitable cell for cell The parameter selection. A smaller modification has no value of this V100R001C00 impact on the parameter results in equipment. a higher probability. Set this parameter properly so that the selected cells can provide signals that meet the quality requirement of basic services.

Radio

None

A larger value of this parameter leads to a higher probability of the The parameter cell meeting criteria modification has no S and becoming a V100R001C00 impact on the suitable cell for cell equipment. selection. A smaller value of this parameter results in a lower probability.

Radio

None

A larger parameter value for a cell leads to lower probabilities of the cell meeting criteria S and becoming a suitable cell for cell selection. A smaller value of this parameter leads to The parameter higher probabilities. modification has no Set this parameter V100R004C00 impact on the properly so that the equipment. selected cell can provide signals that meet the quality requirement of basic services. If the value of this parameter is not specified, the default value (negative infinity) is used.

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

A larger value of this parameter leads to higher probabilities of the cell meeting criteria S and becoming a suitable cell for cell selection. A smaller The parameter value of this modification has no parameter results in V100R004C00 impact on the lower probabilities. equipment. If this parameter is not set, that is, the value of this parameter is not sent to the UE over the air interface, the UE retains the default value (0).

Radio

None

N/A

None

V100R001C01

Radio

None

If this parameter is set to BOOLEAN_FALSE and air interface resources are insufficient in smallbandwidth scenarios, data volume to be scheduled for SI messages cannot be increased in each TTI by The parameter adjusting the code modification has no rate. If this V100R002C00 impact on the parameter is set to equipment. BOOLEAN_TRUE, data volume to be scheduled for SI messages can be increased in each TTI by adjusting the code rate to increase the number of retransmissions while ensuring the cell coverage performance. A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect.

Radio

None

Radio

None

None

None

A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect. A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect. A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect.

Radio

Radio

Radio

None

None

None

A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect. A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect. A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R001C01 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect.

Radio

Radio

Radio

None

None

A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R004C00 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect. A larger value of this parameter results in a smaller number of transmissions in a unit of time and a smaller amount of The parameter occupied system modification has no V100R004C00 resources, but it impact on the may also lead to a equipment. longer delay in UE's acquisition of the system information. A smaller value of this parameter leads to an opposite effect. The parameter modification has no None impact on the equipment.

Radio

Radio

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None The setting of the PassLossCoeff parameter affects that of the P0NominalPUSCH parameter. If PassLossCoeff is set to a small value, it is recommended that P0NominalPUSCH be set to a large value to achieve higher sector throughput. If PassLossCoeff is set to a large value, it is recommended that P0NominalPUSCH be set to a small value to ensure higher data rates for cell edge users (CEUs). For example, if PassLossCoeff is set to 0, it is recommended that P0NominalPUSCH be set to a large value such as -10; if PassLossCoeff is set to 1, it is

N/A

None

V100R001C00

Radio

To guarantee the throughput of the serving cell, set this The parameter parameter to a large modification has no value. To guarantee V100R001C00 impact on the the total throughput equipment. of the network, set this parameter to a small value.

Radio

None

A larger value of this parameter leads to higher throughput in the cell but lower total throughput in the entire network. A The parameter smaller value of this modification has no parameter leads to V100R001C00 impact on the lower throughput in equipment. the cell and also lower interference to neighboring cells, which thereby results in higher total throughput in the entire network.

Radio

The setting of the P0NominalPUSCH parameter affects that of the PassLossCoeff parameter. If P0NominalPUSCH is set to a large value, it is recommended that PassLossCoeff be set to a small value to achieve higher sector throughput. If P0NominalPUSCH is set to a small value, it is recommended that PassLossCoeff be set to a large value to ensure higher data rates for cell edge users (CEUs).

When P0NominalPUSCH is set to an excessively high value, the cell throughput is increased, but the throughput of the The parameter entire network is modification has no decreased. When V100R001C00 impact on the P0NominalPUSCH equipment. is set to an excessively low value, the cell throughput is decreased. The throughput of the entire network, however, is increased.

Radio

None

The PUCCH transmit power is The parameter set based on this modification has no parameter for the V100R001C00 impact on the specific PUCCH equipment. format to guarantee the PUCCH performance.

Radio

None

The PUCCH transmit power is The parameter set based on this modification has no parameter for the V100R001C00 impact on the specific PUCCH equipment. format to guarantee the PUCCH performance. The PUCCH transmit power is The parameter set based on this modification has no parameter for the V100R001C00 impact on the specific PUCCH equipment. format to guarantee the PUCCH performance. The PUCCH transmit power is The parameter set based on this modification has no parameter for the V100R001C00 impact on the specific PUCCH equipment. format to guarantee the PUCCH performance. The PUCCH transmit power is The parameter set based on this modification has no parameter for the V100R001C00 impact on the specific PUCCH equipment. format to guarantee the PUCCH performance.

Radio

None

Radio

None

Radio

None

Radio

None

A relatively small value of this parameter may result in inadequate transmit power for message 3, leading to a reduced transmit power for the data channel and lower The parameter throughput of the modification has no cell. A relatively V100R001C00 impact on the large value of this equipment. parameter may result in excessive transmit power for message 3, leading to stronger interference to neighboring cells and lower throughput of the network.

Radio

None

N/A

None

V100R001C00

Radio

None

A smaller value of this parameter leads to a shorter period that nonuplink-time-aligned UEs transmit sounding reference signals (SRSs) and therefore fewer The parameter SRSs available for modification has no uplink-time-aligned V100R001C00 impact on the UEs. A larger value equipment. of this parameter hampers timely alignment for users with high-speed services and therefore may cause them to become non-uplinktime-aligned.

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R002C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification takes effect after the cell is automatically reset.

Modifications on this parameter affect the orthogonality of the V100R001C00 preamble sequences for the cell and its neighboring cells.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C01

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

This parameter must be set The parameter properly to ensure modification has no that changes in V100R001C00 impact on the radio interference equipment. do not affect UE services in this cell.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Radio

None

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R004C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

N/A

None

V100R003C00

Radio

None

A larger value of this parameter leads to less measurement The parameter reports, which will modification has no affect the prompt V100R003C00 impact on the update of UE equipment. locations and the average throughput of cell edge users (CEUs). A larger value of this parameter leads to higher estimation accuracy The parameter of interference from modification has no neighboring cells, V100R003C00 impact on the better service equipment. quality and larger average throughput of cell edge UEs (CEUs).

Radio

None

Radio

None

A larger value of this parameter leads to greater power consumption of the UE, but improves the throughput of cell edge users (CEUs) more effectively in dynamic ICIC mode. A smaller value of this parameter leads to less power The parameter consumption of the modification has no UE, but affects the V100R003C00 impact on the timely tracing of equipment. neighboring cells for CEUs. In this situation, the interferenceinducing neighboring cell cannot be correctly determined, which may affect the throughput gain for CEUs and even decrease the throughput for them in dynamic ICIC mode.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

A larger value of this parameter leads to a lower probability of both The parameter triggering a DL ICIC modification has no measurement event V100R003C00 impact on the and stopping the equipment. event. A smaller value of this parameter leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower probability of The parameter meeting the modification has no entering or leaving V100R003C00 impact on the condition of the DL equipment. ICIC measurement event. A smaller value leads to a higher probability.

Radio

None

A larger value of this parameter leads to a lower probability of triggering a DL ICIC measurement event and accordingly a smaller number of UEs that report related measurements. As a result, service quality is not guaranteed for CEUs, leading to The parameter drops in CEU modification has no throughput and cell V100R003C00 impact on the capacity. equipment. A smaller value of this parameter results in a higher probability of triggering a DL ICIC measurement event and accordingly a larger number of UEs that report related measurements. As a result, more UEs occupy the edge frequency band and the average CEU throughput drops. N/A None V100R002C00

Radio

None

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no impact on the equipment.

A larger value of this parameter indicates a wider CIO adjustment range for the serving cell.

V100R004C00

Radio

None

The parameter modification has no impact on the equipment.

A smaller value of this parameter indicates a wider CIO adjustment range for the serving cell.

V100R004C00

Radio

None

N/A

None

V100R001C01

Radio

None

A larger value of this parameter results in a larger number of Goldlevel services and hence higher usage The parameter of system resources modification has no by Gold-level V100R001C01 impact on the services. If this equipment. parameter is set to a small value, however, there is no impact on the radio network performance.

Radio

None

A larger value of this parameter leads to a larger number of Silverlevel services and hence more system The parameter resources occupied modification has no by Gold- and Silver- V100R001C01 impact on the level services. If this equipment. parameter is set to a small value, however, there is no impact on the radio network performance.

Radio

None

If the value of this parameter is too small, the admission threshold is too low for the handed-over service with QCI of 1. In this case, the QoS of the existing The parameter services cannot be modification has no guaranteed. V100R001C01 impact on the If the value of this equipment. parameter is too large, the admission threshold is too high for the handed-over service with QCI of 1. In this case, the admission success rate is low for services with QCI of 1.

Radio

None

If the value of this parameter is too small, the admission threshold is too low for the handed-over service with QCI of 2. In this case, the QoS of the existing The parameter services cannot be modification has no guaranteed. V100R001C01 impact on the If the value of this equipment. parameter is too large, the admission threshold is too high for the handed-over service with QCI of 2. In this case, the admission success rate is low for services with QCI of 2. If the value of this parameter is too small, the admission threshold is too low for the handed-over service with QCI of 3. In this case, the QoS of the existing The parameter services cannot be modification has no guaranteed. V100R001C01 impact on the If the value of this equipment. parameter is too large, the admission threshold is too high for the handed-over service with QCI of 3. In this case, the admission success rate is low for services with QCI of 3.

Radio

None

Radio

None

If the value of this parameter is too small, the admission threshold is too low for the handed-over service with QCI of 4. In this case, the QoS of the existing The parameter services cannot be modification has no guaranteed. V100R001C01 impact on the If the value of this equipment. parameter is too large, the admission threshold is too high for the handed-over service with QCI of 4. In this case, the admission success rate is low for services with QCI of 4.

Radio

None

If the value of this parameter is too small, the admission threshold is too low for new Gold-level services of all QCIs. In this case, the Gold-level services occupy too many system resources, and Silver- and Bronzelevel services The parameter cannot be admitted. modification has no This affects the V100R001C01 impact on the access success equipment. rates of the Silveror Bronze-level services of all QCIs. If the value of this parameter is too large, the admission threshold is too high for new Gold-level services. In this case, the access success rate is low for Gold-level services.

Radio

None

If the value of this parameter is too small, the admission threshold is too low for new Silver-level services of all QCIs. In this case, the Gold- and Silver-level services occupy too many system resources, and Bronze-level The parameter services cannot be modification has no admitted. This V100R001C01 impact on the affects the access equipment. success rates of the Bronze-level services of all QCIs. If the value of this parameter is too large, the admission threshold is too high for new Silver-level services. In this case, the access success rate is low for Silver-level services.

Radio

None

A smaller value of the parameter leads to a lower admission threshold for new Bronzelevel services of all QCIs. This may cause excessive service admission and hence affect The parameter the QoS of the modification has no admitted services. V100R001C01 impact on the A larger value of the equipment. parameter results in a higher admission threshold for new Bronze-level services of all QCIs, which may decrease the access success rate of Bronze-level services.

Radio

None

A larger value of this parameter leads to a higher probability of system congestion. In this situation, the system resource usage and the access success rate are low. A smaller value of this parameter leads to a lower probability of generating The parameter congestion modification has no indications and V100R001C01 impact on the therefore a higher equipment. access success rate. If the value is small, an excessive number of users may be admitted, but the load control actions are not taken in time to relieve the congestion. In this situation, the overall QoS satisfaction rate of the existing services decreases and the call drop rate increases.

Radio

None

A larger value of this parameter results in a higher probability of system congestion. If the value is large, the system resource usage and the access success rate are low. A smaller value of this parameter results in a lower probability of generating The parameter congestion modification has no indications and V100R001C01 impact on the hence a higher equipment. access success rate. If the value is small, an excessive number of users might be admitted, but the load control actions are not taken in time to relieve the congestion. In this case, the overall QoS satisfaction rate of the existing services drops and the call drop rate rises.

Radio

None

A larger value of this parameter leads to a higher probability of system congestion. In this case, the system resource utilization and the access success rate are low. A smaller value of this parameter leads to a lower probability of generating The parameter congestion modification has no indications and V100R001C01 impact on the hence a higher equipment. access success rate. If the value is small, an excessive number of users might be admitted, but the load control actions are not taken in time to relieve the congestion. In this case, the overall QoS satisfaction rate of the existing services drops and the call drop rate rises.

Radio

None

A larger value of this parameter indicates a higher probability of system congestion. If the value is large, the system resource usage and the access success rate are low. A smaller value of this parameter leads to a lower probability of generating The parameter congestion modification has no indications and V100R001C01 impact on the hence a higher equipment. access success rate. If the value is small, an excessive number of users might be admitted, but the load control actions are not taken in time to relieve the congestion. In this case, the overall QoS satisfaction rate of the existing services drops and the call drop rate rises.

Radio

None

A smaller value of the parameter results in higher efficiency of load control, but may cause a greater fluctuation in the QoS satisfaction rate of Gold-level GBR services. The parameter A larger value of the modification has no parameter causes a V100R002C00 impact on the smaller impact on equipment. the QoS satisfaction rate of Gold-level services and hence lower efficiency of load control. In this case, both the probability of leaving the congested state and the access success rate are lower.

Radio

None

A smaller value of this parameter results in higher efficiency of load control, but it also leads to a greater fluctuation in the QoS satisfaction rate of Silver-level GBR services. The parameter A larger value of modification has no this parameter V100R002C00 impact on the leads to a smaller equipment. impact on the QoS satisfaction rate of Silver-level services and lower efficiency of load control. In this case, the probability of leaving the congested state and the access success rate are lower.

Radio

None

A smaller value of this parameter results in higher efficiency of load control, but may cause a greater fluctuation in the QoS satisfaction rate of Bronze-level GBR services. A larger value of The parameter this parameter modification has no causes a smaller V100R002C00 impact on the impact on the QoS equipment. satisfaction rate of Bronze-level services, but results in lower efficiency of load control. In this case, both the probability of leaving the congested state and the access success rate are lower.

Radio

None

A smaller value of this parameter results in a smaller quantity of resources allowed to be occupied by GBR services and a lower admission success rate of GBR services, The parameter thereby causing a modification has no higher probability of V100R001C01 impact on the resource waste. equipment. A larger value of this parameter leads to a larger quantity of resources allowed to be occupied by GBR services and a smaller quantity of resources reserved for non-GBR services.

Radio

None

A smaller value of this parameter results in a lower probability of switching from a high-usage indication to a lowusage indication about GBR services. As a result, the The parameter probability of GBR modification has no service admission impact on the failure is higher. equipment. A larger value of this parameter results in a higher probability of pingpong effect in terms of switching between the highusage indication and the low-usage indication about GBR services.

V100R001C01

Radio

None

A larger value of this parameter indicates a smaller number of services that can be released by the system and results in a lower probability of congestion relief. A smaller value of this parameter indicates a larger number of services that can be The parameter released by the modification has no system and results V100R001C01 impact on the in a higher equipment. probability of congestion relief and a higher call drop rate. The priority of the Gold-level, Silverlevel, and Bronzelevel services should be considered for the setting of the ARP threshold. If the value of this parameter is too small, even Goldlevel services may

Radio

None

A larger value of this parameter leads to a lower probability of congestion relief. In the case of congestion, services are released as a load The parameter control action, and modification has no therefore the call V100R001C01 impact on the drop rate is equipment. increased. A smaller value of this parameter results in a higher probability of congestion relief, but it may lead to frequent switching between overload and overload relief.

Radio

None

A larger value of this parameter results in fewer types of preemptible service and a lower access success rate of high-priority users by means of preemption. Therefore, the highThe parameter priority users have modification has no worse experience. V100R002C00 impact on the A smaller value of equipment. this parameter results in more types of preemptible service and a higher access success rate of high-priority users by means of preemption. In this case, the call drop rate is higher.

Radio

None

A larger value of this parameter leads to a lower probability of generating the high usage indication of UL RBs, which may cause excessive admission, but the protection over resource allocation is performed after the admission decision. In addition, when the The parameter value of the modification has no parameter is too V100R001C01 impact on the large, load control equipment. actions are taken more slowly. A smaller value of this parameter leads to a higher probability of generating the high usage indication of UL RBs, but the satisfaction rates are compared further to make admission decisions. Therefore, the parameter has no

Radio

None

A larger value of this parameter leads to a lower probability of generating the high usage indication of DL RBs, which may cause excessive admission, but the protection for resource allocation is performed after the admission decision. In addition, when the The parameter value of the modification has no parameter is too V100R001C01 impact on the large, load control equipment. actions are taken more slowly. A smaller value of this parameter leads to a higher probability of generating the high usage indication of DL RBs but the satisfaction rates are compared further for admission decision. Therefore, this parameter has no obvious impact on

Radio

None

A larger value of this parameter leads to a higher probability of generating the low usage indication of UL RBs, which may cause excessive admission, but the protection for resource allocation is performed after the admission decision. Therefore, this parameter does The parameter not affect the the modification has no overall QoS V100R001C01 impact on the satisfaction rate equipment. much. A smaller value of this parameter leads to a lower probability of generating the low usage indication of UL resources resource blocks and hence a lower admission success rate, but the protection for resource allocation is performed after the admission

Radio

None

A larger value of this parameter leads to a higher probability of generating the low usage indication of DL RBs, which may cause excessive admission, but the protection for resource allocation is performed after the admission decision. Therefore, this parameter has The parameter no obvious impact modification has no on the overall QoS V100R001C01 impact on the satisfaction rate. equipment. A smaller value of this parameter leads to a lower probability of generating the low usage indication of UL resources resource blocks and hence a lower admission success rate, but the protection for resource allocation is performed after the admission decision. Therefore,

Radio

None

A smaller value of this parameter results in fewer nonThe parameter GBR services that modification has no can be admitted; a V100R001C01 impact on the larger value of this equipment. parameter results in more non-GBR services that can be admitted.

Radio

None

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Radio

None

The parameter modification takes effect after the cell is automatically reset. N/A

None

V100R005C00

Radio

None

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

N/A

None

V100R003C00

Radio

None

A larger value of this parameter leads to less measurement The parameter reports, which will modification has no affect the prompt V100R003C00 impact on the update of UE equipment. locations and the average throughput of cell edge users (CEUs).

Radio

None

A larger value of this parameter leads to higher estimation accuracy The parameter of interference from modification has no neighboring cells, V100R003C00 impact on the better service equipment. quality and larger average throughput of cell edge UEs (CEUs).

Radio

None

A larger value of this parameter leads to greater power consumption of the UE, but improves the throughput of cell edge users (CEUs) more effectively in dynamic ICIC mode. A smaller value of this parameter leads to less power The parameter consumption of the modification has no UE, but affects the V100R003C00 impact on the timely tracing of equipment. neighboring cells for CEUs. In this situation, the interferenceinducing neighboring cell cannot be correctly determined, which may affect the throughput gain for CEUs and even decrease the throughput for them in dynamic ICIC mode.

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

A larger value of this parameter leads to a lower probability of both The parameter triggering a UL ICIC modification has no measurement event V100R003C00 impact on the and stopping the equipment. event. A smaller value of this parameter leads to a higher probability.

Radio

None

A larger value of this parameter results in a lower probability of The parameter meeting the modification has no entering or leaving V100R003C00 impact on the condition of the UL equipment. ICIC measurement event. A smaller value leads to a higher probability.

Radio

None

A large value of this parameter leads to a low probability of triggering a UL ICIC measurement event and hence a small number of UEs that report the related measurements. As a result, the service qualities provided for CEUs may not be guaranteed, leading to drops in The parameter CEU throughput modification has no and cell capacity. V100R003C00 impact on the A small value of this equipment. parameter results in a high probability of triggering a UL ICIC measurement event and hence a large number of UEs that report the related measurements. As a result, more UEs may occupy the edge frequency band and the throughput of each CEU may drop.

Radio

None

N/A

None

V100R002C00

Radio

None

If this parameter is set to ULSCH_STRATEG Y_EPF, the QoS is guaranteed, and the coverage, capacity, and fairness are considered. If this parameter is set to ULSCH_STRATEG Y_MAX_CI, the system capacity is maximized, but the coverage, fairness, and QoS are not The parameter guaranteed. If this modification has no parameter is set to V100R002C00 impact on the ULSCH_STRATEG equipment. Y_PF, a tradeoff among the coverage, capacity, and fairness is reached, but the QoS is not guaranteed. If this parameter is set to ULSCH_STRATEG Y_RR, the eNodeB guarantees that each UE has an equal opportunity to be scheduled in UL, but the capacity, coverage and QoS

Radio

None

Setting this parameter to ADAPTIVE_HARQ_ SW_ON helps reduce resource consumption due to retransmission, The parameter increase the cell modification has no throughput, and V100R002C00 impact on the prevent equipment. retransmission conflicts. This, on the other hand, will increase signaling overhead and therefore consume more PDCCH resources.

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R002C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

A larger value of this parameter leads to a shorter service delay. An excessively large value of this parameter, however, decreases the transmission efficiency. A smaller The parameter value of this modification has no parameter leads to V100R004C00 impact on the a longer service equipment. delay. Note that when the user data volume is smaller than the value of this parameter, setting this parameter to a smaller value will increase the transmission efficiency.

Radio

None

An excessively large value of this parameter may lead The parameter to a waste of modification has no resources due to a V100R004C00 impact on the delayed implicit equipment. release of semipersistent resources.

Radio

None

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R001C00

Radio

None

RachAdjSwitch: If this switch is turned on, based on the number of accessed UEs, the algorithm can improve the utilization of dedicated preambles while ensuring that the probability is less than or equal to 1% that a UE with the random access procedure triggered The parameter by handover (case modification has no 3) or arrival of V100R001C00 impact on the downlink data (case equipment. 4) is not allocated with a dedicated preamble. In addition, the algorithm can also improve the PRACH utilization while ensuring that the probability is less than or equal to 1% that multiple UEs initiate random access procedures triggered by initial access (case 1), failed radio link

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

If the switch is turned on, the PUCCH resources are increased or decreased adaptively based on the load on the PUCCH. This achieves better utilization of PUCCH resources and reduces UL control signaling overhead. When V100R001C00 the PUCCH resources are decreased, however, a few users may need to reconfigure the CQI resources, which consumes certain DL resources. If the switch is turned off, the UL control signaling overhead is relatively large.

Radio

None

When a PDCP packet queue is congested, the automatic packet discarding mechanism is The parameter started if modification has no AqmAlgoSwitch is V100R001C00 impact on the set to ON. This equipment. reduces the delay of interactive services, but it slightly increases the time used to download large-sized files.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

DlSwitch: If this switch is set to OFF, the admission evaluation based on the satisfaction rate is not performed for new or handed-over services in the downlink. In this case, there is a relatively high probability of overload in the downlink. The parameter If this switch is set modification has no to ON, the V100R001C01 impact on the admission equipment. evaluation based on the satisfaction rate is performed for new and handedover services in the downlink. UlSwitch: If this switch is set to OFF, the admission evaluation based on the satisfaction rate is not performed for new or handed-over services in the uplink. In this case,

Radio

None

If the intrafrequency load balancing switch is set to OFF, the intrafrequency MLB function is disabled. In this case, intrafrequency load imbalances cannot be handled. Therefore, the probability of overload is relatively high, and the access success The parameter rate and the total modification has no throughput are V100R002C00 impact on the relatively low. If this equipment. switch is set to ON, the intra-frequency MLB function is enabled. Then, in the case that the load in the cell is heavy and there is an imbalance in the load between cells, the probability of overload in the system is relatively low, and the access success rate and the total throughput are relatively high.

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

If FreqPriorIFHOSwitc h is set to On, the frequency-prioritybased interfrequency handover is enabled. It increases the number of handovers, but improves the data rate of the UE. To speed up handover, you are advised to set both The parameter FreqPriorIFHOSwitc modification has no h and V100R003C00 impact on the FreqPriorIFBlindHO equipment. Switch to On. In addition, to ensure handover success rate, strictly set the triggering conditions of the frequencypriority-based interfrequency handover; for example, set the threshold related to event A1 to a large value. The purpose is to decrease the number of UEs that will be handed over

Radio

None

If the switch is turned on, the downlink average throughput in a The parameter heavily loaded cell modification has no is relatively high. V100R004C00 impact on the Turn off this switch equipment. if a cell is lightly loaded or multi-user pairing is not desired.

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

If this parameter is set to ACBAR_SWITCH_ DYNAMIC, the access probability factor and the average access The parameter barring duration for modification has no mobile-originated V100R005C00 impact on the calls are equipment. dynamically adjusted based on the current cell load. In this way, the probabilities of UEs accessing the cell can be controlled to relieve the cell load.

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

If this parameter is used, the eNodeB performs differentiation control between the P2P service and the non-P2P service that are carried by the non-GBR bearer. In this case, The parameter when traffic is modification has no heavy in a cell, the V100R001C00 impact on the data rate of the P2P equipment. service on the air interface can be effectively controlled on the basis of the userdefined priority, thereby preventing the P2P service from severely impacting on other services in the cell.

Radio

None

A larger value of this parameter indicates a larger amount of resources allocated to non-P2P services. A smaller value of this parameter indicates a smaller The parameter amount. modification has no Adjustment of the V100R001C00 impact on the parameter value will equipment. affect the throughput in a cell. Whether the throughput will increase or decrease depends on the distribution of UEs that request non-P2P services in the cell.

Radio

None

Indicates the maximum number of layers (the rank) in the implementation of The parameter multiple-input modification has no multiple-output impact on the (MIMO) in DL equipment. scheduling. The value of this parameter has a significant impact on the throughput under MIMO.

V100R004C00

Radio

None

N/A

None

V100R002C00

Radio

None

The value of this parameter has an obvious impact on the use of the MLB algorithm. A large value of this parameter may lead to the situation The parameter where the optimum modification has no balancing among V100R002C00 impact on the the cell load is not equipment. reached when overload occurs. A small value of this parameter, however, may lead to excessive handovers and signaling exchanges.

Radio

None

The value of this parameter has an obvious impact on the use of the MLB algorithm. A large value of this parameter may lead to the situation The parameter where the optimum modification has no balancing among V100R002C00 impact on the the cell load is not equipment. reached when overload occurs. A small value of this parameter, however, may lead to excessive handovers and signaling exchanges.

Radio

None

The value of this parameter has an obvious impact on the use of the interRAT MLB algorithm. A large value of this parameter may lead to the situation where the optimum balancing among The parameter the cell load is not modification has no reached when V100R002C00 impact on the overload occurs. A equipment. small value, however, may cause excessive inter-RAT handovers. This may deteriorate the system performance since the inter-RAT handover has a low success rate.

Radio

None

A small value of this parameter may cause frequent load updates and induce The parameter excessive signaling modification has no overhead. A large V100R002C00 impact on the value of this equipment. parameter may hinder the cell from timely obtaining the load status in neighboring cells.

Radio

None

A large value of this parameter may cause difficulties in timely triggering the load balancing when the cell load is unbalanced, or cause difficulties in The parameter timely stopping the modification has no load balancing V100R002C00 impact on the when the cell load is equipment. balanced. A small value of this parameter, however, may result in the frequent triggering or stopping of the load balancing algorithm.

Radio

None

If this parameter is set to a large value, load balancing may The parameter not be initiated or modification has no stopped in time. If V100R003C00 impact on the this parameter is set equipment. to a small value, load balancing may be initiated and stopped frequently.

Radio

None

N/A

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The value of this parameter determines whether to perform dynamic adjustment of the UL-to-DL CCE ratio on the PDCCH. The parameter Changing the value modification has no of this parameter V100R003C00 impact on the affects the number equipment. of available UL and DL CCEs. This further affects the number of scheduled users and the UL and DL throughput.

Radio

None

The parameter modification has no impact on the equipment.

Changing the value of this parameter V100R003C00 affects the DL throughput.

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The setting of the switch determines whether to perform dynamic adjustment of the number of OFDM symbols occupied by PDCCH. If this switch is turned off, PDCCH occupies the fixed number of The parameter OFDM symbols in modification has no each TTI. If this V100R003C00 impact on the switch is turned on, equipment. the number of OFDM symbols occupied by PDCCH is dynamically adjusted based on the number of UEs to be scheduled in each TTI, maximizing the system capacity.

Radio

None

If an upper limit is applied to the CCE usage within each TTI, the number of The parameter scheduled users modification has no drops, affecting the V100R004C00 impact on the UL and DL equipment. throughout and even the service quality and the maximum number of UEs in the cell.

Radio

None

The setting of the switch determines whether to adjust the PDCCH aggregation level based on the BLER of the PDCCH. After this switch is turned on, the BLER of the PDCCH can converge to the target BLER value. If the BLER is far below the target The parameter value before the modification has no switch is turned on, V100R005C00 impact on the the number of equipment. control channel elements (CCEs) for each UE can be reduced to improve cell capacity after the switch is turned on. If the BLER is far above the target value before the switch is turned on, the BLER can converge to the target value to improve the cell coverage after the switch is turned on. N/A None V100R001C00

Radio

None

Radio

None

A larger value of this parameter leads to less The parameter available SRI modification has no resources. impact on the A smaller value of equipment. this parameter leads to more available SRI resources.

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C01

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

If the length of the default paging cycle is fixed, a larger value of this parameter results in a longer modification period and a larger number of times that UEs are required to read system information V100R001C00 change notifications, which leads to higher reliability of acquiring such notifications. A longer modification period, however, results in a longer delay in the system information change.

Radio

None

N/A

None

V100R001C00

Radio

None

None

The setting of this parameter affects the coverage of the PCFICH channel. A larger value of this parameter leads to a better coverage performance, but induces stronger radio interference to The parameter neighboring cells. modification has no This causes a V100R001C00 impact on the waste of power and equipment. reduces available power for the PHICH and PDCCH channels. A smaller value of this parameter, however, may lead to insufficient coverage and coverage holes. The setting of this parameter affects the coverage area of the PBCH channel. A larger value of this parameter results in better coverage The parameter performance, but it modification has no induces stronger V100R001C00 impact on the interference to equipment. neighboring cells and may cause a waste of power. A smaller value of this parameter, however, may lead to insufficient coverage and coverage holes.

Radio

Radio

None

The setting of this parameter affects the coverage performance of the SCH channel. A larger value of this parameter results in better coverage The parameter performance, but it modification has no induces stronger V100R001C00 impact on the interference to equipment. neighboring cells and may cause a waste of power. A smaller value of this parameter, however, may lead to insufficient coverage and coverage holes.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

1) Coverage: If the value of ReferenceSignalPw r is too large, crosscoverage occurs. This causes interference to other cells. If the value of ReferenceSignalPw r is too small, coverage holes appear. 2) Interference: The setting of ReferenceSignalPw The parameter r varies with the modification has no interference from V100R001C00 impact on the neighboring cells. A equipment. large interference margin is required where the interference is strong. 3) Channel estimation: A larger value of ReferenceSignalPw r leads to higher channel estimation accuracy, a lower demodulation threshold, and higher receiver sensitivity, but it A larger value of Pb results in a larger increase in ReferenceSignalPw r, better channel estimation performance, and The parameter better PDSCH modification has no demodulation V100R001C00 impact on the performance. equipment. Meanwhile, it also leads to lower transmit power of the PDSCH (type B) and therefore increases the data rate of cell edge users (CEUs).

Radio

None

Radio

None

N/A

None

V100R001C00

Radio

None

A larger value of this parameter leads to higher throughput in the cell but lower total throughput in the entire network. A The parameter smaller value of this modification has no parameter leads to V100R001C00 impact on the lower throughput in equipment. the cell and also lower interference to neighboring cells, which thereby results in higher total throughput in the entire network.

Radio

None

A larger value of this parameter leads to higher throughput in the cell but lower total throughput in the entire network. A The parameter smaller value of this modification has no parameter leads to V100R001C00 impact on the lower throughput in equipment. the cell and also lower interference to neighboring cells, which thereby results in higher total throughput in the entire network.

Radio

None

The value of this The parameter parameter has a modification has no negative correlation V100R005C00 impact on the with the cell equipment. coverage.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

The modification to this parameter will affect the interference between the PRACH of the current cell and the PUSCH of a neighboring cell or between the PUSCH of the V100R005C00 current cell and the PRACH of a neighboring cell. The modification to this parameter will affect the maximum number of consecutive RBs that can be scheduled on the PUSCH.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R005C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

The starting position in the time domain and appearance period of the PRACH can be specified based on the setting of this parameter. A smaller PRACH interval can reduce the probability of V100R005C00 preamble collision during contentionbased random access, and reduce the average access delay. A larger PRACH interval, however, can lower the UL resource utilization of the PRACH.

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

If this parameter is set to BOOLEAN_TRUE, the beamforming performance is ensured, DL openloop and closedloop adaptive MIMO is supported, and UE pairing performance for MUMIMO is ensured, but the UL peak throughput decreases. If this parameter is V100R005C00 set to BOOLEAN_FALSE, the UL peak throughput increases, but the beamforming performance cannot be ensured, DL open-loop and closed-loop adaptive MIMO is not supported, and UE pairing performance for MUMIMO cannot be ensured.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

If this parameter is set to ACCESS_FIRST, the number of UEs in TDD cells can reach the upper limit, but the performance of features that rely on SRS resources cannot be ensured. V100R005C00 If this parameter is set to EXPERIENCE_FIR ST, the UL throughput of TDD cells can reach the upper limit and the optimal beamforming performance can be achieved.

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

A large value of this parameter indicates a large amount of occupied control channel resources and a small constraint on the uplink scheduling. A V100R001C00 small value of this parameter indicates a small amount of occupied control channel resources and a great constraint on the uplink scheduling.

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

The values of this parameter and the NB parameter determine the number of paging occasions, that is, the number of paging groups. A larger value of this parameter leads to a longer delay in paging a UE but helps reduce the power consumption of the UE. A smaller V100R001C00 value of this parameter leads to a shorter delay in paging a UE but causes more power consumption of the UE. If the EPC specifies a DRX period for a UE, the UE uses the smaller value between the period and the parameter value as its DRX period. For a certain paging load, a larger value of this parameter indicates a larger paging capacity during a specific V100R001C00 period, and a smaller value of this parameter indicates a smaller paging capacity during a specific period.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

As a supplement to planning of base sequence groups for UL RS generation, group hopping simplifies the planning and randomizes UL RS correlation interference. Though the current group hopping can significantly reduce the probability of collisions that neighboring cells use the same base V100R001C00 sequence group in a TTI, it cannot completely prevent such collisions. a) When the number of cells is smaller than 30, the reuse of base sequence groups does not occur. In this case, group hopping is not required. Therefore, it is recommended that group hopping be disabled. b) When the

Radio

None

When GroupAssignPUSC H of all cells under one eNodeB is set to 0, the UL RSs on the PUSCHs are generated on the basis of different base sequence groups. In this case, each cell can use any Cyclic Shift (CS) value during the generation of the UL RS. The The parameter more the available modification has no CS values, the V100R001C00 impact on the more the V-MIMO equipment. users that can be matched. When GroupAssignPUSC H of cells under one eNodeB is set to different values, the UL RSs on the PUSCHs can be generated on the basis of the same base sequence. Thus, the orthogonality of UL RSs between neighboring cells

Radio

None

The parameter modification takes effect after the cell is automatically reset.

When group hopping is not performed, sequence hopping can be supported. After base sequences are divided into groups, the base sequences within each group have great correlations (the base sequences are almost regarded as identical). The correlations between a base V100R001C00 sequence in group A and the base sequences in group B are similar to those between any other base sequence in group A and the base sequences in group B. Thus, sequence hopping is equivalent to the use of an identical base sequence in each TTI, which does not result in an obvious difference

Radio

None

When all cells under one eNodeB use the same base sequence group to generate UL RSs on PUSCHs, different CyclicShift values need to be set for these cells The parameter so that the cells use modification has no different cyclic shifts V100R001C00 impact on the during semiequipment. persistent scheduling. When the cells under one eNodeB use different base sequence groups to generate UL RSs on PUSCHs, set CyclicShift to 0.

Radio

None

The parameter modification takes effect after the cell is automatically reset. N/A

None

V100R001C00

Radio

None

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R001C00

Radio

None

The parameter modification takes effect after the cell is automatically reset.

If this parameter is set to a large value, the cell can serve more UEs at the expense of increased UL signaling overhead. V100R005C00 If this parameter is set to a small value, the cell can serve fewer UEs, and this also reduces the UL signaling overhead.

Radio

None

The parameter modification takes effect after the cell is automatically reset.

If this parameter is set to a large value, the cell can serve more UEs supporting periodic CQI reporting, however, this also increases the UL signaling overhead. V100R005C00 If this parameter is set to a small value, the cell serves less UEs supporting periodic CQI reporting, and this also reduces the UL signaling overhead.

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Where, Mn is the measurement value of neighboring cells. Ofn is the frequencyspecific offset of the neighboring cell, Thresh is the threshold for this event, and Hys refers to the The parameter hysteresis for this modification has no event. V100R001C00 impact on the The smaller the equipment. value of Ofn is, the harder event B1 is triggered, and the more slowly the handover is implemented. This affects the user experience. The bigger the value of Ofn is, the easier event B1 is triggered. This also easily causes error decisions and pingpong handovers.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R002C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R003C00

Radio

None

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

A larger value of this parameter indicates a higher The parameter probability of a UE modification has no camping on the V100R001C00 impact on the cells assigned with equipment. the band class, and a smaller value indicates a lower probability.

Radio

None

A larger value of this parameter leads to a lower probability of a UE The parameter camping on a cell modification has no on a frequency in V100R001C00 impact on the the higher-priority equipment. CDMA2000 band class, and a smaller value indicates a higher probability.

Radio

None

A larger value of this parameter leads to a lower probability of a UE The parameter camping on a cell modification has no on a frequency in V100R001C00 impact on the the lower-priority equipment. band class, and a smaller value leads to a higher probability.

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A larger value of this parameter indicates a higher probability of a UE The parameter camping on the cell modification has no on a frequency in V100R001C00 impact on the the GERAN carrier equipment. frequency group, and a smaller value indicates a lower probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A larger value of this parameter leads to a lower probability of a neighboring cell on a frequency in the GERAN carrier frequency group becoming a suitable The parameter cell for cell modification has no selection. A smaller V100R001C00 impact on the value of this equipment. parameter leads to a high probability. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

Radio

None

When other conditions unchanged, a larger value of this parameter leads to a lower probability The parameter of reselection to a modification has no neighboring cell on V100R001C00 impact on the a frequency in the equipment. higher-priority carrier frequency group, and a smaller value of this parameter leads to a higher probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to a lower probability The parameter of reselection to a modification has no neighboring cell on V100R001C00 impact on the a frequency in the equipment. lower-priority carrier frequency group, and a smaller value of this parameter leads to a higher probability.

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Where, Mn is the measurement value of neighboring cells. Ofn is the frequencyspecific offset of the neighboring cell, Thresh is the threshold for event B1, and Hys is the The parameter hysteresis for event modification has no B1. V100R001C00 impact on the The smaller the equipment. value of Ofn is, the harder event B1 is triggered, and the more slowly the handover is implemented. This affects the user experience. The bigger the value of Ofn is, the easier event B1 is triggered. This also easily causes error decision and pingpong handover.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

A larger value of this parameter leads to a higher The parameter probability of modification has no triggering event A3 V100R001C00 impact on the and handover. A equipment. smaller value of this parameter leads to a lower probability.

Radio

None

Increasing the value of this parameter causes the cell edge to move towards the The parameter neighboring cell, modification has no which leads to a V100R001C00 impact on the lower probability of equipment. cell reselection to the neighboring cell. Decreasing the value of this parameter leads to an opposite effect.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A larger value of this parameter leads to a higher probability of starting The parameter measurements on modification has no cells on the V100R001C00 impact on the neighboring Eequipment. UTRAN frequency and also a higher probability of reselection to a cell on the frequency.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no cell reselection V100R001C00 impact on the duration within Eequipment. UTRAN, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

A smaller value of this parameter results in a greater impact of the UE The parameter mobility state on the modification has no cell reselection V100R001C00 impact on the duration within Eequipment. UTRAN, that is, results in a shorter duration. A larger value leads to a smaller impact.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A larger value of this parameter The parameter leads to a lower modification has no probability of V100R001C00 impact on the reselection to a equipment. neighboring cell on the frequency.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to the V100R001C00 impact on the cell on the higherequipment. priority frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R001C00 impact on the neighboring cell on equipment. the lower-priority EUTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

A larger value of this parameter leads to a lower probability of a neighboring cell on the frequency meeting criteria S and becoming a The parameter suitable cell for modification has no selection. A smaller V100R001C00 impact on the value of this equipment. parameter leads to a higher probability. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

Setting this parameter to EventA3 improves the performance of handovers to intraband interfrequency The parameter neighboring cells in modification has no terms of timeliness V100R003C00 impact on the and interference. equipment. Setting this parameter to EventA4 reduces the number of interband interfrequency handovers.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R004C00 impact on the neighboring cell on equipment. the higher-priority EUTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R004C00 impact on the neighboring cell on equipment. the lower-priority EUTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

A larger value of this parameter leads to a lower probability of the cell meeting criterion S and becoming a suitable cell selected by a The parameter UE. A smaller value modification has no of this parameter V100R004C00 impact on the leads to a higher equipment. probability. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

A larger value of this parameter results in lower probabilities of The parameter triggering event A4 modification has no and therefore V100R001C00 impact on the performing equipment. handovers. A smaller value of this parameter results in an opposite effect.

Radio

None

Increasing the value of this parameter causes the cell edge to move towards the The parameter neighboring cell, modification has no which leads to a V100R001C00 impact on the lower probability of equipment. cell reselection to the neighboring cell. Decreasing the value of this parameter leads to an opposite effect.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

N/A

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

None

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

N/A

N/A

None

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

A larger value of this parameter leads to a higher probability of starting The parameter measurements on modification has no neighboring cells on V100R001C00 impact on the the UTRAN equipment. frequency and also a higher probability of reselection to a neighboring cell on the frequency.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The entering condition of event B1 is as follows: Mn + Ofn - Hys > Thresh. Where, Mn is the measurement value of neighboring cells, Ofn is the frequency-specific offset of the neighboring cell. Thresh is the threshold for event B1. Hys is the hysteresis for event The parameter B1. modification has no A smaller value of V100R001C00 impact on the Ofn results in a equipment. lower probability of triggering an event B1. This may delay the handover and affect the user experience. A larger value of Ofn leads to a higher probability of triggering an event B1, which may cause handover decision errors and ping-pong handovers. A larger value of this parameter leads to a lower probability of the UTRAN FDD cell to meet criterion S and become a suitable cell selected by a The parameter UE. A smaller value modification has no of this parameter V100R001C00 impact on the results in a higher equipment. probability. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

Radio

None

Radio

None

A larger value of this parameter leads to a lower probability of the UTRAN cell to meet criterion S and become a suitable cell selected by a The parameter UE. A smaller value modification has no of this parameter V100R001C00 impact on the results in a higher equipment. probability. Set this parameter properly so that the selected cell can provide signals that meet the quality requirement of basic services.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R001C00 impact on the neighboring cell on equipment. the higher-priority UTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R001C00 impact on the neighboring cell on equipment. the lower-priority UTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R004C00 impact on the neighboring cell on equipment. the higher-priority UTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

With other conditions unchanged, a larger value of this parameter leads to The parameter a lower probability modification has no of reselection to a V100R004C00 impact on the neighboring cell on equipment. the higher-priority UTRAN frequency, and a smaller value of this parameter leads to a higher probability.

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

N/A

N/A

None

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The TPE algorithm, if enabled, increases the rate of TCP services; if disabled, has no impact on the network. If the TPE algorithm is enabled, the source The parameter eNodeB of a modification has no handover will V100R002C00 impact on the transmit the TCP equipment. packets stored in the TPE buffer to the target eNodeB so that the server does not need to transmit the same set of packets to the target eNodeB, increasing the rate of TCP services.

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification takes effect after the cell is automatically reset.

None

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R003C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R004C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R005C00

Radio

None

N/A

None

V100R001C01

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C00

Radio

None

The parameter modification has no None impact on the equipment.

V100R001C01

Radio

None

The parameter modification has no impact on the equipment.

This switch can be turned on to prevent traffic bursts in the V100R005C00 downlink, which is caused by ACKs to uplink TCP packets.

Radio

None

If the parameter value is smaller than the data rate over the air interface, the The parameter downlink throughput modification has no will decrease. If the V100R005C00 impact on the parameter value is equipment. much greater than the data rate over the air interface, the TCP ACK control algorithm cannot take effect. A smaller value of this parameter results in better The parameter performance for the modification has no TCP ACK control V100R005C00 impact on the algorithm, and a equipment. larger value of this parameter leads to a heavier system load.

Radio

None

Radio

None

The parameter modification takes effect after the cell is automatically reset.

In a scenario where the TDD E-UTRAN coexists with another TDD network such as WiMAX, TDSCDMA, or PHS and the spectrums of the two networks are close to each other, strong interference may be resulted if uplink and downlink timeslots between V100R003C00 the two networks are not synchronized. This parameter is used to adjust the frame start time for all TDD E-UTRAN cells in order to ensure that the uplink and downlink timeslots of the TDD E-UTRAN cells are consistent with those of the other network.

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R002C00

Radio

None

V100R002C00

Radio

None

V100R002C00

Radio

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

None

V100R001C01

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The eNodeB cannot access the network if this parameter is set to DISABLE and The parameter no IPSec tunnel has modification has no been set up V100R001C01 impact on the between the equipment. eNodeB and the SeGW for the SGW in an IPSecprotected network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPSec is applied to a network with this parameter set V100R005C00 to DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

None

V100R001C01

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The eNodeB cannot access the network if this parameter is set to DISABLE and The parameter no IPSec tunnel has modification has no been set up V100R001C01 impact on the between the equipment. eNodeB and the SeGW for the MME in an IPSecprotected network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The eNodeB cannot access the network if this parameter is set to DISABLE and The parameter no IPSec tunnel has modification has no been set up V100R001C01 impact on the between the equipment. eNodeB and the SeGW for the MME in an IPSecprotected network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R002C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPsec is applicable but this parameter is set to V100R005C00 DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The eNodeB cannot access the network if this parameter is set to DISABLE and The parameter no IPSec tunnel has modification has no been set up V100R001C01 impact on the between the local equipment. eNodeB and the neighboring eNodeB in an IPSecprotected network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The eNodeB cannot access the network if this parameter is set to DISABLE and The parameter no IPSec tunnel has modification has no been set up V100R001C01 impact on the between the local equipment. eNodeB and the neighboring eNodeB in an IPSecprotected network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

If IPSec is applied to the transport The parameter network and this modification has no parameter is set to V100R001C01 impact on the DISABLE, the equipment. eNodeB cannot access the transport network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no impact on the equipment.

If IPv6 IPSec is used in the network but this parameter V100R005C00 is set to DISABLE, the eNodeB cannot access the network.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and a neighboring V100R005C00 impact on the IPv6 eNodeB, but equipment. this parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and the IPv6 V100R005C00 impact on the SeGW, but this equipment. parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and a neighboring V100R005C00 impact on the IPv6 eNodeB, but equipment. this parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and the IPv6 V100R005C00 impact on the SeGW, but this equipment. parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and the neighboring V100R005C00 impact on the IPv6 eNodeB, but equipment. this parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and the IPv6 V100R005C00 impact on the SeGW, but this equipment. parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and the neighboring V100R005C00 impact on the IPv6 eNodeB, but equipment. this parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

If IPv6 IPSec is used in the network, no IPv6 IPSec tunnel has been configured between The parameter the local eNodeB modification has no and the IPv6 V100R005C00 impact on the SeGW, but this equipment. parameter is set to DISABLE, then handovers cannot be performed over the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network The parameter but this parameter modification has no is set to DISABLE, V100R005C00 impact on the user service traffic equipment. cannot be forwarded through the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network The parameter but this parameter modification has no is set to DISABLE, V100R005C00 impact on the user service traffic equipment. cannot be forwarded through the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network The parameter but this parameter modification has no is set to DISABLE, V100R005C00 impact on the user service traffic equipment. cannot be forwarded through the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If IPv6 IPSec is used in the network The parameter but this parameter modification has no is set to DISABLE, V100R005C00 impact on the user service traffic equipment. cannot be forwarded through the X2 interface.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A N/A

N/A N/A

None None

V100R001C01 V100R001C01

Transport Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

V100R001C01

Transport

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

V100R005C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

The MANAME value of each CFM N/A MA must be unique in a CFM MD.

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment. N/A None

V100R001C01

Transport

None

V100R001C01

Transport

N/A

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A N/A

N/A N/A

None None

V100R001C01 V100R001C01

Transport Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

When the DHCP relay switch is enabled, the BS The parameter automatically modification has no forwards the DHCP V100R001C00 impact on the requests from the equipment. lower-level BS, which increases the load of data processing.

Transport

N/A

N/A

None

V100R001C00

Transport

None

If this parameter is set to DISABLE, a The parameter faulty remote modification has no maintenance impact on the channel cannot equipment. automatically restore itself.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no impact on the equipment.

A smaller parameter value indicates a lower transmission V100R001C00 priority of signaling data and affects the QoS.

Transport

None

A smaller parameter value indicates a The parameter lower transmission modification has no priority of high-level V100R001C00 impact on the OM service data equipment. and affects the QoS.

Transport

None

This parameter value must be different from the priorities of other The parameter services, so that lowmodification has no level OM service V100R001C00 impact on the data (such as equipment. upload and download data) is allocated the minimal bandwidth through scheduling.

Transport

None

A smaller parameter value indicates a The parameter lower transmission modification has no priority of the V100R001C01 impact on the Precision Time equipment. Protocol (PTP) packets and affects the QoS.

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 1 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 2 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 3 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 4 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 5 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 6 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 7 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 8 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

A smaller parameter value indicates a lower transmission The parameter priority of the modification has no service packet V100R001C00 impact on the whose QoS Class equipment. Indicator (QCI) is 9 and affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

If this parameter is set to OFF, the throughput on the air interface will The parameter drop due to modification has no overload of the V100R003C00 impact on the central processing equipment. unit (CPU) when the DL traffic on the S1 interface exceeds the capability of the LBBP.

Transport

None

If this parameter is set to OFF, the throughput on the air interface will The parameter drop due to modification has no overload of the V100R003C00 impact on the central processing equipment. unit (CPU) when the DL traffic on the S1 interface exceeds the capability of the LBBP.

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R004C00

Transport

N/A

N/A

None

V100R004C00

Transport

N/A

N/A

None

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

An excessive large parameter value leads to packet loss or excessivelyfragmented data packets on the transport network, resulting in a long delay and The parameter deteriorated modification has no performance. An V100R001C00 impact on the excessive small equipment. parameter value leads to reduced available payloads for transmission, resulting in decreased transport bandwidth efficiency and deteriorated performance.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R004C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

None

An excessive large parameter value leads to packet loss or excessivelyfragmented data packets on the transport network, resulting in a long delay and The parameter deteriorated modification has no performance. An V100R001C01 impact on the excessive small equipment. parameter value leads to decreased available payloads for transmission, resulting in ineffective use of the transport network bandwidth and deteriorated performance.

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

Modifications to this parameter affect the The parameter admission of new modification has no services and the V100R003C00 impact on the quality of admitted equipment. services carried on resource groups.

Transport

None

Modifications to this parameter affect the The parameter admission of new modification has no services and the V100R003C00 impact on the quality of admitted equipment. services carried on resource groups.

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment. N/A None

V100R003C00

Transport

N/A

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The setting of this parameter must be consistent with that at the peer NE. Modifications on this parameter are not allowed.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

This parameter must be set to the same value as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

This parameter value must be the same as the peer IP address. Modifications on this parameter value are not allowed.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The REMOTENAME value of the IKE peer is case insensitive and cannot contain any non-ASCII characters. The local end and peer end must have the same setting of this parameter.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

The setting of this parameter must be consistent with that at the peer NE. Modifications on this parameter are not allowed.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

This parameter must be the same as the peer IP address. Modifications on this parameter are not allowed.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

The REMOTENAME value of the IKE peer is case insensitive and cannot contain any non-ASCII characters. The local end and peer end must have the same setting of this parameter.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A N/A

N/A N/A

None None

V100R001C00 V100R005C00

Transport Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C01

Transport

If this parameter is set to DISABLE, the connectivity of an IP path cannot be checked.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

If this parameter is set to DISABLE, the continuity of the IPv6 path cannot be checked.

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

When this parameter is set to BIDIR, the IP PM session resource at the peer end is occupied. During the current session, N/A another IP PM session with the same DSCP that is established on the same IP path cannot be activated at the peer end.

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R004C00

Transport

N/A

N/A

None

V100R004C00

Transport

The SPGN value is case insensitive. When the SPGN value is referenced, however, the name of the policy group N/A must be exactly the same as the configured one. Otherwise, the related operation fails.

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

V100R001C01

Transport

N/A

N/A

None

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

The SPGN value is case insensitive. When the SPGN value is referenced, however, the name of the policy group N/A must be the same as the configured one. Otherwise, the related operation fails.

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

The referenced value of this parameter must be exactly the same as N/A the configured name. Otherwise, the related operation fails.

None

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

The value of this parameter must be the same as that at the peer NE.

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

If this parameter is set to ENABLE, the rate of a physical port is restricted. If this parameter is set to DISABLE, the rate of a physical port is not restricted.Rate The parameter restriction of modification has no physical ports is V100R001C00 impact on the necessary if the equipment. bandwidth of a transport network is limited. The transport network may incur congestion or packet loss when its bandwidth is limited and rate restriction is disabled.

Transport

None

If this parameter value is greater than the available transport bandwidth, the transport network may be congested, affecting the QoS. The parameter If this parameter modification has no value is smaller V100R001C00 impact on the than the available equipment. transport bandwidth, the transport network may incur a waste of bandwidth, affecting the number of admitted services and throughput.

Transport

None

A smaller parameter value indicates a lower tolerance for data burst, which results in packet The parameter loss. modification has no A larger parameter V100R001C00 impact on the value indicates equipment. higher consumption of system resources, which results in a waste of resources.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

Enabling the Pointto-Point Protocol (PPP) multiplexing function leads to V100R001C00 higher bandwidth usage and a longer delay for data transmission. None V100R001C00

Transport

N/A

N/A

Transport

N/A

N/A

A smaller parameter value indicates a smaller number of frames available for multiplexing, resulting in a lower multiplexing ratio. A larger parameter V100R001C00 value indicates a larger number of frames available for multiplexing but a lower multiplexing ratio, resulting in inadequate multiplexing. A larger parameter value indicates a larger number of multiplexed frames and a higher multiplexing efficiency, resulting in a longer delay caused by V100R001C00 multiplexing. A smaller parameter value indicates a smaller number of multiplexed frames, resulting in a shorter delay caused by multiplexing.

Transport

N/A

N/A

Transport

N/A

N/A

A smaller parameter value indicates a smaller number of multiplexed frames and lower bandwidth usage, resulting in a short delay. A larger parameter value indicates a V100R001C00 large number of multiplexed frames if the maximum multiplexed frame length is not considered. In this case, the bandwidth usage is higher, resulting in a longer delay.

Transport

N/A

N/A

None.

V100R001C00

Transport

N/A

N/A

After this parameter is set to ENABLE, the IP header compression is enabled, which improves bandwidth V100R001C00 usage, increases data processing loads, and decreases the throughput.

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A N/A N/A

N/A N/A N/A

None None None

V100R001C00 V100R001C00 V100R001C00

Transport Transport Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

A smaller parameter value indicates smaller received V100R001C00 data units and more data fragments, affecting the QoS.

Transport

N/A

N/A

After the Protocol Field Compression (PFC) function is enabled, the bandwidth usage is V100R001C00 improved, which results in higher system loads and a longer delay. After the Address and Control Field Compression (ACFC) function is enabled, the V100R001C00 bandwidth usage is improved, which results in higher system loads and a longer delay.

Transport

N/A

N/A

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

N/A

None

V100R003C00

Transport

None

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

The password must not contain the following N/A characters: <, >, !, ?, and :.

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

Enabling the Pointto-Point Protocol (PPP) multiplexing function leads to V100R001C00 higher bandwidth usage and a longer delay for data transmission.

Transport

N/A

N/A

A smaller parameter value indicates a smaller number of frames available for multiplexing, resulting in a lower multiplexing ratio. A larger parameter value indicates a V100R001C00 larger number of frames available for multiplexing but a lower multiplexing ratio, resulting in a low impact of the multiplexing algorithm. A larger parameter value indicates a larger number of multiplexed frames and a higher multiplexing efficiency, resulting in a longer delay caused by V100R001C00 multiplexing. A smaller parameter value indicates a smaller number of multiplexed frames, resulting in a shorter delay caused by multiplexing.

Transport

N/A

N/A

Transport

N/A

N/A

A smaller parameter value indicates a smaller number of multiplexed frames and lower bandwidth usage, resulting in a short delay. A larger parameter value indicates a V100R001C00 large number of multiplexed frames if the maximum multiplexed frame length is not considered. In this case, the bandwidth usage is higher, resulting in a longer delay. After this parameter is set to ENABLE, the IP header compression is performed, resulting V100R001C00 in higher bandwidth usage and line quality requirements. A smaller parameter value indicates smaller received V100R001C00 data units and more data fragments, affecting the QoS.

Transport

N/A

N/A

Transport

N/A

N/A

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

After the Address and Control Field Compression (ACFC) function is enabled, the V100R001C00 bandwidth usage is improved, which results in higher system loads and a longer delay.

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

None

A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services. A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services.

Transport

Transport

None

None

A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services. A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services.

Transport

Transport

None

None

A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services. A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services.

Transport

Transport

None

A lower priority of the real-time service queue leads to the preemption of nonreal-time services by excessive realtime-services. A higher priority of The parameter real-time service modification has no queue leads to V100R001C00 impact on the degrading of realequipment. time services to the non-real-time service queue, resulting in the preemption of realtime services by non-real-time services.

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

If this parameter value is greater than the available transport bandwidth, the transport network may be congested, affecting the QoS. The parameter If this parameter modification has no value is smaller V100R003C00 impact on the than the available equipment. transport bandwidth, the transport network may incur a waste of bandwidth, affecting the number of admitted services and throughput.

Transport

None

If this parameter value is greater than the available transport bandwidth, the transport network may be congested, affecting the QoS. The parameter If this parameter modification has no value is smaller V100R003C00 impact on the than the available equipment. transport bandwidth, the transport network may incur a waste of bandwidth, affecting the number of admitted services and throughput.

Transport

None

A smaller parameter value indicates a lower tolerance for data burst, which results in packet The parameter loss. modification has no A larger parameter V100R003C00 impact on the value indicates equipment. higher consumption of system resources, which results in a waste of resources.

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

If this parameter value is greater than the guaranteed transport bandwidth for uplink, packet loss is easy to occur on non-flow-control services, affecting the QoS of these services. The parameter If this parameter modification has no value is smaller V100R003C00 impact on the than the guaranteed equipment. transport bandwidth for uplink, bandwidth waste may occur on the transport network, affecting the number of admitted non-flow-control services and the BS throughput in the uplink.

Transport

None

If this parameter value is greater than the guaranteed transport bandwidth for downlink, packet loss is easy to occur on non-flow-control services, affecting the QoS of these services. The parameter If this parameter modification has no value is smaller V100R003C00 impact on the than the guaranteed equipment. transport bandwidth for downlink, bandwidth waste may occur on the transport network, affecting the number of admitted non-flow-control services and the BS throughput in the uplink. If this parameter value is greater than the maximum transport bandwidth for uplink, packet loss is easy to occur on the transport network, affecting the QoS of services. The parameter If this parameter modification has no value is smaller V100R003C00 impact on the than the maximum equipment. transport bandwidth for uplink, bandwidth waste may occur on the transport network, affecting the number of admitted services and the BS throughput in the uplink.

Transport

None

Transport

None

If this parameter value is greater than the maximum transport bandwidth for downlink, packet loss is easy to occur on the transport network, affecting the QoS of services. The parameter If this parameter modification has no value is smaller V100R003C00 impact on the than the maximum equipment. transport bandwidth for downlink, bandwidth waste may occur on the transport network, affecting the number of admitted services and the BS throughput in the uplink.

Transport

None

A larger parameter The parameter value indicates a modification has no greater amount of impact on the permitted burst equipment. data.

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

N/A

N/A

None

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

If this parameter is set to ON, packet loss can be reduced by adjusting the TX bandwidth of the The parameter transport network. modification has no If this parameter is V100R001C00 impact on the set to OFF, the equipment. bandwidth and TX rate is not adjusted due to packet loss on the transport network.

Transport

None

If this parameter is set to ON, packet loss is reduced by adjusting the RX bandwidth of the The parameter transport network. modification has no If this parameter is V100R001C00 impact on the set to OFF, the equipment. bandwidth and RX rate is not adjusted due to packet loss on the transport network.

Transport

None

A smaller parameter value indicates a higher probability of detecting congestion on the transport network and being affected by packet loss due to transport network The parameter errors, which leads modification has no to a mistaken rate V100R001C00 impact on the decrease. equipment. A larger parameter value indicates a lower probability of detecting congestion on the transport network and being affected by packet loss due to transport network errors.

Transport

None

A smaller parameter value indicates a higher probability of detecting congestion on the transport network and being affected by delay jitter when the transport network is not congested, which The parameter may lead to a modification has no mistaken rate V100R001C00 impact on the decrease. equipment. A larger parameter value indicates a lower probability of detecting congestion on the transport network and being affected by delay jitter when the transport network is not congested.

Transport

None

The minimum TX bandwidth that the adjustment can achieve has a positive correlation with the value of this parameter. That is, if this parameter The parameter is set to a smaller modification has no value, the minimum V100R001C00 impact on the TX bandwidth that equipment. the adjustment can achieve is smaller; if this parameter is set to a larger value, the minimum TX bandwidth that the adjustment can achieve is larger.

Transport

None

The minimum RX bandwidth that the adjustment can achieve has a positive correlation with the value of this parameter. That is, if this parameter The parameter is set to a smaller modification has no value, the minimum V100R001C00 impact on the RX bandwidth that equipment. the adjustment can achieve is smaller; if this parameter is set to a larger value, the minimum RX bandwidth that the adjustment can achieve is larger.

Transport

None

If this parameter is set to ENABLE, the transport resource group will not be congested, guaranteeing the fairness and differentiation of The parameter non-real-time modification has no services. V100R001C00 impact on the If this parameter is equipment. set to DISABLE, the transport resource group may be congested, affecting the fairness and differentiation of non-real-time services.

Transport

None

If this parameter is set to ENABLE, the OM FTP services may preempt the The parameter bandwidth of nonmodification has no real-time services. V100R001C00 impact on the If this parameter is equipment. set to DISABLE, only a low bandwidth is guaranteed for OM FTP services.

Transport

None

All real-time services belong to the Priority Queuing The parameter (PQ) queue. modification has no Otherwise, the high V100R001C00 impact on the priority of equipment. transmitting realtime services is not guaranteed.

Transport

None

A smaller parameter value indicates a higher probability of the TX rate change of the transport The parameter resource group but modification has no a shorter delay. V100R001C00 impact on the A larger parameter equipment. value indicates a lower probability of the TX rate change of the transport resource group but a longer delay.

Transport

None

A smaller parameter value indicates a better differentiation effect for bandwidth allocation of nonreal-time services. This, however, leads to a higher probability of emptying the buffer of the transport resource group and affects the The parameter bandwidth usage. modification has no A larger parameter V100R001C00 impact on the value indicates a equipment. worse differentiation effect for bandwidth allocation of nonreal-time services. This, however, leads to a lower probability of emptying the buffer of the transport resource group and is unlikely to affect the bandwidth usage. If this parameter is set to an excessively great value, some UL bandwidths are wasted and the system capacity The parameter decreases. modification has no If this parameter is V100R001C01 impact on the set to an equipment. excessively small value, the actrual transmission load will exceed the UL available bandwidth, affecting the quality of admitted services.

Transport

None

Transport

None

If this parameter is set to an excessively great value, some DL bandwidths are wasted and the system capacity The parameter decreases. modification has no If this parameter is V100R001C01 impact on the set to an equipment. excessively small value, the actrual transmission load will exceed the DL available bandwidth, affecting the quality of admitted services.

Transport

None

A greater value indicates a larger The parameter capability of the modification has no queue in a impact on the transmission equipment. resource group to buffer packets.

V100R001C01

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

N/A

N/A

None

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

If this parameter is set to ON, admission decision for handover services or new services depends on uplink transport resources. This prevents excessive service admission and ensures the quality of admitted The parameter services. modification has no If this parameter is V100R001C00 impact on the set to OFF, equipment. admission decision for handover services or new services does not depend on uplink transport resources. Therefore, the QoS of ongoing services cannot be ensured if excessive services are admitted. If this parameter is set to ON, admission decision for handover services or new services depends on downlink transport resources. This prevents excessive service admission and ensures the quality The parameter of admitted modification has no services. V100R001C00 impact on the If this parameter is equipment. set to OFF, admission decision for handover services or new services does not depend on downlink transport resources. Therefore, the QoS of ongoing services cannot be ensured if excessive services are admitted.

Transport

None

Transport

None

A smaller parameter value indicates a larger number of admitted services and a lower probability of ensuring sufficient The parameter bandwidth for modification has no ongoing services. V100R001C00 impact on the A larger parameter equipment. value indicates a smaller number of admitted services and a higher probability of ensuring sufficient bandwidth for ongoing services. A smaller parameter value indicates a larger number of admitted services and a lower probability of ensuring sufficient The parameter bandwidth for modification has no ongoing services. V100R001C00 impact on the A larger parameter equipment. value indicates a smaller number of admitted services and a higher probability of ensuring sufficient bandwidth for ongoing services.

Transport

None

Transport

None

A smaller parameter value indicates a larger number of admitted services and a lower probability of ensuring sufficient The parameter bandwidth for modification has no ongoing services. V100R001C00 impact on the A larger parameter equipment. value indicates a smaller number of admitted services and a higher probability of ensuring sufficient bandwidth for ongoing services. A smaller parameter value indicates a larger number of admitted services and a lower probability of ensuring sufficient The parameter bandwidth for modification has no ongoing services. V100R001C00 impact on the A larger parameter equipment. value indicates a smaller number of admitted services and a higher probability of ensuring sufficient bandwidth for ongoing services.

Transport

None

Transport

None

A smaller value indicates a larger number of admitted services but a smaller probability of ensuring the sufficient bandwidth The parameter for ongoing modification has no services. V100R001C00 impact on the A larger value equipment. indicates a smaller number of admitted services but a greater probability of ensuring the sufficient bandwidth for ongoing services. A less parameter value indicates that more services can be admitted. The possibility that bandwidth for services is not The parameter ensured, however, modification has no becomes great. V100R001C00 impact on the A greater parameter equipment. value indicates that fewer services can be admitted. The possibility that bandwidth for services is not ensured, however, becomes less.

Transport

None

Transport

None

A less parameter value indicates that more services can be admitted. The possibility that bandwidth for services is not The parameter ensured, however, modification has no becomes great. V100R001C00 impact on the A greater parameter equipment. value indicates that fewer services can be admitted. The possibility that bandwidth for services is not ensured, however, becomes less. A less parameter value indicates that more services can be admitted. The possibility that bandwidth for services is not The parameter ensured, however, modification has no becomes great. V100R001C00 impact on the A greater parameter equipment. value indicates that fewer services can be admitted. The possibility that bandwidth for services is not ensured, however, becomes less.

Transport

None

Transport

None

A less parameter value indicates that more services can be admitted. The possibility that bandwidth for services is not The parameter ensured, however, modification has no becomes great. V100R001C00 impact on the A greater parameter equipment. value indicates that fewer services can be admitted. The possibility that bandwidth for services is not ensured, however, becomes less. A larger value indicates a higher admission success rate of handover services but a greater probability of overloaded transport due to the actual traffic The parameter fluctuation of realmodification has no time services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of handover services but a smaller probability of overloaded transport due to the traffic fluctuation of real-time services.

Transport

None

Transport

None

A larger value indicates a higher admission success rate of handover services but a greater probability of overloaded transport due to the actual traffic The parameter fluctuation of realmodification has no time services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of handover services but a smaller probability of overloaded transport due to the traffic fluctuation of real-time services. A larger value indicates a higher admission success rate of gold-level new services but a smaller UL bandwidth reserved for handover services and less effect of The parameter differentiating modification has no admitted services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of gold-level new services but a greater UL bandwidth reserved for handover services and more effect of differentiating admitted services.

Transport

None

Transport

None

A larger value indicates a higher admission success rate of gold-level new services but a smaller DL bandwidth reserved for handover services and less effect of The parameter differentiating modification has no admitted services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of gold-level new services but a greater DL bandwidth reserved for handover services and more effect of differentiating admitted services. A larger value indicates a higher admission success rate of silver-level new services but a smaller UL bandwidth reserved for gold-level new services and less effect of The parameter differentiating modification has no admitted services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of silver-level new services but a greater UL bandwidth reserved for gold-level new services and more effect of differentiating admitted services.

Transport

None

Transport

None

A larger value indicates a higher admission success rate of silver-level new services but a smaller DL bandwidth reserved for gold-level new services and less effect of The parameter differentiating modification has no admitted services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of silver-level new services but a greater DL bandwidth reserved for gold-level new services and more effect of differentiating admitted services. A larger value indicates a higher admission success rate of bronze-level new services but a smaller UL bandwidth reserved for silver-level new services and less effect of The parameter differentiating modification has no admitted services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of bronze-level new services but a greater UL bandwidth reserved for silver-level new services and more effect of differentiating admitted services.

Transport

None

Transport

None

A larger value indicates a higher admission success rate of bronze-level new services but a smaller DL bandwidth reserved for silver-level new services and less effect of The parameter differentiating modification has no admitted services. V100R002C00 impact on the A smaller value equipment. indicates a lower admission success rate of bronze-level new services but a greater DL bandwidth reserved for silver-level new services and more effect of differentiating admitted services. A greater value of this parameter indicates a greater UL admission bandwidth for GBR services and a higher admission success rate of GBR services but a smaller UL bandwidth reserved The parameter for non-GBR modification has no services. V100R002C00 impact on the A smaller value of equipment. this parameter indicates a smaller UL admission bandwidth for GBR services and a lower admission success rate of GBR services but a greater UL bandwidth reserved for non-GBR services.

Transport

None

Transport

None

A greater value of this parameter indicates a greater DL admission bandwidth for GBR services and a higher admission success rate of GBR services but a smaller DL bandwidth reserved The parameter for non-GBR modification has no services. V100R002C00 impact on the A smaller value of equipment. this parameter indicates a smaller DL admission bandwidth for GBR services and a lower admission success rate of GBR services but a greater DL bandwidth reserved for non-GBR services.

Transport

None

If the UL transport bandwidth is insufficient and this parameter is set to ON, the admission success rate of highpriority services may rise, but the call drop rate of lowpriority services The parameter may also increase. modification has no If the UL transport V100R002C00 impact on the bandwidth is equipment. insufficient and this parameter is set to OFF, the call drop rate of low-priority services is not affected, but the admission success rate of high-priority services is not guaranteed.

Transport

None

If this parameter is set to ON when the DL transport bandwidth is insufficient, the admission success rate of high-priority services increases. The service drop rate of low-priority services, however, The parameter also increases. modification has no If this parameter is V100R002C00 impact on the set to OFF when the equipment. DL transport bandwidth is insufficient, the admission success rate of high-priority services might not increase. The service drop rate of low-priority services, however, is not affected.

Transport

None

If this parameter is set to ON, the sum of uplink admission bandwidths of all logical ports carried on a physical port is allowed to be greater than the uplink bandwidth of the physical port. In this case, however, there is a risk of excessive admitted services if PORTULCACSW is The parameter set to ON. modification has no If this parameter is V100R003C00 impact on the set to OFF, the sum equipment. of uplink admission bandwidths of all logical ports carried on a physical port is not allowed to be greater than the uplink bandwidth of the physical port. In this case, there is no risk of excessive admitted services regardless of whether PORTULCACSW is set to ON.

Transport

None

If this parameter is set to ON, the sum of downlink admission bandwidths of all logical ports carried on a physical port is allowed to be greater than the downlink bandwidth of the physical port. In this case, however, there is a risk of excessive admitted services if The parameter PORTDLCACSW is modification has no set to ON. V100R003C00 impact on the If this parameter is equipment. set to OFF, the sum of downlink admission bandwidths of all logical ports carried on a physical port is not allowed to be greater than the downlink bandwidth of the physical port. In this case, there is no risk of excessive admitted services regardless of whether PORTDLCACSW is

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

If this parameter is set to ON, the quality of highpriority services is guaranteed when the transport network is The parameter overloaded with modification has no uplink services. impact on the If this parameter is equipment. set to OFF, the quality of highpriority services is guaranteed when the transport network is overloaded with uplink services.

V100R001C00

Transport

None

If this parameter is set to ON, the quality of highpriority services is guaranteed when the transport network is overload The parameter with downlink modification has no services. V100R001C00 impact on the If this parameter is equipment. set to OFF, the quality of highpriority services is not guaranteed when the transport network is overloaded with downlink services.

Transport

None

A larger parameter value indicates a lower probability of triggering the UL transport overload algorithm, ensuring the bandwidth of high-priority services, and The parameter releasing lowmodification has no priority services. V100R001C00 impact on the A smaller parameter equipment. value indicates a higher probability of triggering the UL transport overload algorithm, ensuring the bandwidth of high-priority services, and releasing lowpriority services. A larger parameter value indicates a smaller number of services released by OLC and a higher probability of The parameter OLC ping-pong modification has no operations. V100R001C00 impact on the A smaller parameter equipment. value indicates a larger number of services released by OLC and a lower probability of OLC ping-pong operations.

Transport

None

Transport

None

A smaller parameter value indicates a longer time to clear the overload state and a lower probability of The parameter releasing services modification has no excessively. V100R001C00 impact on the A larger parameter equipment. value indicates a shorter time to clear the overload state and a higher probability of releasing services excessively. A larger parameter value indicates a lower probability of triggering the DL transport overload algorithm, ensuring the bandwidth of high-priority services, and The parameter releasing lowmodification has no priority services. V100R001C00 impact on the A smaller parameter equipment. value indicates a higher probability of triggering the DL transport overload algorithm, ensuring the bandwidth of high-priority services, and releasing lowpriority services.

Transport

None

Transport

None

A larger parameter value indicates a smaller number of services released by OLC and a higher probability of The parameter OLC ping-pong modification has no operations. V100R001C00 impact on the A smaller parameter equipment. value indicates a larger number of services released by OLC and a lower probability of OLC ping-pong operations.

Transport

None

The parameter modification has no None impact on the equipment.

V100R002C00

Transport

N/A

N/A

None

V100R004C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R005C00

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C01

Transport

N/A

N/A

None

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment. The parameter modification has no impact on the equipment.

V100R001C00

Transport

None

A smaller parameter value indicates a lower priority of the V100R001C00 data transmission in layer 2 and affects the QoS.

Transport

N/A

N/A

None

V100R001C00

Transport

N/A

N/A

None

V100R001C01

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

A smaller parameter The parameter value indicates a modification has no lower priority of data V100R001C00 impact on the transmission and equipment. affects the QoS.

Transport

None

The parameter modification has no None impact on the equipment.

V100R001C00

Transport

None

The parameter modification has no None impact on the equipment.

V100R003C00

Transport

None

A larger value of this parameter makes ECHO frame timeout less vulnerable to network delay, but it leads to a longer time required to detect disconnection and The parameter therefore a higher modification has no probability of longV100R001C01 impact on the time packet loss. A equipment. smaller value of this parameter results in a higher probability of detecting network status, but it leads to higher sensitivity to packet loss and delay and therefore a higher probability of incorrect decisions. A larger value of this parameter makes ECHO frame timeout less vulnerable to network delay, but it leads to a longer time required to detect disconnection and The parameter therefore a higher modification has no probability of longV100R001C01 impact on the time packet loss. A equipment. smaller value of this parameter results in a higher probability of detecting network status, but it leads to higher sensitivity to packet loss and delay and therefore a higher probability of incorrect decisions.

Transport

None

Transport

None

A larger value of this parameter makes ECHO frame timeout less vulnerable to network delay, but it leads to a longer time required to detect disconnection and The parameter therefore a higher modification has no probability of longV100R001C01 impact on the time packet loss. A equipment. smaller value of this parameter results in a higher probability of detecting network status, but it leads to higher sensitivity to packet loss and delay and therefore a higher probability of incorrect decisions.

Transport

None

The parameter modification has no None impact on the equipment.