4"

4" DIA. INLET PIPE

6"

3'-0" 3'-8"

LD

4"

3' 0" 3'-8"

4" EQUAL 6" EQUAL EQUAL

PLAN OF SOAKAWAY
SCALE: 3/8" = 1' 0"

6" 6"

EQUAL

4"

EQUAL L L + 1' 0"

4"

EQUAL

6" 6" 6" 6" 6" 6"


2 3

3/4 LD

4" CONCRETE BLOCK WALL 4"

W + 1' 0"

12"

12" x 18" MAN HOLE COVER

4" DIA. OUTLET PIPE TO SOAKAWAY / LEACHFIELD

1'-4"

4" DIA. INLET PIPE FROM WATER CLOSET ONLY

L "L"

1/3 L

6"

10" 6" 6"

18" X 18" CONCRETE COVER

ALL EXTERNAL WALLS ARE 6" CONCRETE BLOCK WALLS WITH ALL CORES FILLED SOLID WITH CONCRETE AND REINFORCED WITH #3 BARS @ 24" C/C
6" 5"

4"

6" 6"

PLAN OF SEPTIC TANK


SCALE: 1/2" = 1' 0"
4" CONCRETE SLAB REINFORCED WITH #3 BARS @ 10" C.C. BOTHWAYS 18" X 18" GRAVEL RANGING 3'-8" CONCRETE FROM 1 2" TO 6" DIA. 4" 4" WITH FINE ROCKS 3'-0" COVER 4" DIA. PLACED AT TOP INLET PIPE AND COARSE ROCKS AT BOTTOM EQUAL

DIMENSIONED SECTION THRU SEPTIC TANK


SCALE: 1/2" = 1' 0" TYPICAL RESIDENTIAL SEWAGE DISPOSAL SYSTEM 4" CONCRETE BLOCK WALL ALL CORES FILLED SOLID WITH CONCRETE AND REINFORCED WITH #3 BARS @ 24" C/C AS SHOWN 4" CONCRETE SLAB REINFORCED WITH #3 BARS 10" C/C BOTHWAYS

6" 6"

PLAN OF SEPTIC TANK


5'-2" 2' 0" min. to water table MASS CONCRETE BASE

EXISTING GROUND LEVEL

SCUM

4" DIA. OUTLET PIPE TO SOAKAWAY/LEACHFIELD

PROJECT TITLE:

CLIENT ADDRESS:

BAFFLE WALL FIRST BLOCK COURSE EMBEDDED IN CONCRETE BASE

REVIEWED BY:

WATER TABLE LEVEL

SECTION THRU SOAKAWAY


SCALE: 3/8" = 1' 0"

6" CONCRETE SLAB REINFORCED WITH # 3 BARS @ 8" C/C BOTHWAYS

P.E.S.
CLIENT NAME:

MIN. OF HEALTH
DRAWN BY:

SECTION THRU SEPTIC TANK


SCALE: 1/2" = 1' 0"

M.E.G.
DATE:

SOAKAWAY DETAILS

SEPTIC TANK DETAILS

SPECIFICATIONS 1. Inlet pipe must dip 12" below liquid level in tank. 2. Tank must be air and water tight. 3. Invert level of outlet pipe must be 2" minimum below top of baffle wall.

APRIL 2010
SCALE:

AS SHOWN
SHEET No.:

TOTAL No. OF SHEETS

SHEET TITLE:

C.B.A.

4" CONCRETE BLOCK WALL

SEPTIC TANK SIZING CHART

6" CONCRETE BLOCK WALL ALL CORES FILLED SOLID WITH CONCRETE AND REINFORCED WITH #3 BARS @ 24" C/C AS SHOWN

2" PLASTER ON BOTH FACES

LIQUID LEVEL 4" DIA. HOLE

2" PLASTER ON BOTH FACES

6" CONCRETE BLOCK WALL ALL CORES FILLED SOLID WITH CONCRETE AND REINFORCED WITH #3 BARS @ 24" C/C AS SHOWN

SEPTIC TANK AND SOAKAWAY DETAILS

4 " DIA. INLET PIPE FROM WATER CLOSET ONLY

12"X18" CONCRETE COVER

4'-10"