Vessel B:
- From UCS 66, for curve B, Impact testing is required - Ref UG 20 (f), material is PNo. 1 Group 1, Thk <= 1 and MDMT > - 20F - Impact testing is exempted
Vessel C:
- From UCS-66, for curve A, Impact tecting is required - Ref UG 20 ( f ) since thk > 0.5 - Impact testing is required
Vessel D:
- From UCS 66, for curve C Impact testing is required ( transition temp from table= -3 deg.F) - Since MDMT < - 20 F, Impact testing is not exempt per UG 20 (f) - But since PWHT is carried out as service requirement ( and not code requirement, Since thk < 1.25.), UG-68 (c) is applicable. Exemption temp = -3 30 = - 33F - Impact testing not required