a complement to the RBS 2000 customer documentation library

Quick Reference Guide-QRG

Exchange of DXU

Action
CPU reset Fault Operational Local mode BS fault External alarm Local/remote

Approximately Result waiting time

1.

Press Local/remote button on the DXU. Save log files (see OMT-QRG) and fill in the Blue Tag.

1. Operational

CPU reset Fault Operational Local mode BS fault External alarm Local/remote

Local mode and BS fault have fixed lights.

IDB

OMT

2.

Read IDB (see OMT-QRG). Fill in Blue Tag.

1 min.
60 45 30 15

2. A progress window
displays when it is ready.

ON

9 DXU 2A

3.

ON

ON

Switch off the fuse for the DXU.

9 DXU 2A
ON

ON

4. Exchange the DXU.

Do NOT connect the Abis connector.

OFF

5.

Switch on the fuse for the new DXU.

Up to 5Min. 0 40 30 10 20

5. Make sure the DXU


is in Local mode, (Operational and Local Mode have fixed lights).

CPU reset Fault Operational Local mode BS fault External alarm Local/remote

IDB

OMT

6. Install the previously


saved IDB or configure a new one (See OMT-QRG)

LZT 123 4394 R3A

Action

Approximately Result waiting time

DXU

Note: If RBS SW is newer than R8_2, Do not press CPU reset and continue with step 7.
CPU reset Fault Operational Local mode

7. Press the CPU reset button

5 Min.

on the DXU and wait 5 min. 40 The DXU is communicating 30 with the TRUs.

10 20

7.

The new DXU is in Local Mode.

Fault Operational Local mode BS fault External alarm

TRU
CPU reset
TRU TXat CPU reset Fault Operational Local mode TX not enabled Test result Local/remote Test call

TX not enabled Test result Local/remote

8. Check that all the TRUs


If not, press the
are in remote mode. Local/remote button.

8. The TRUs are in Remote mode.

Local Mode is flashing and TX not enabled has a fixed light.

Fault Operational Local mode TX not enabled Test result Local/remote

RXA in

RXB in

TRU

9.

Connect the Abisconnector.

BS fault External alarm Local/remote

10. Press Local/remote

button on the DXU.

11.
WAIT!

Wait until Operational has a fixed light on all units. If the BSC needs to download new software, this can take up to 30 min.

30 Min. 0 40 30 10 20

11. Operational has a


fixed light on all units.

Fault Operational Local mode BS fault External alarm

LZT 123 4394 R3A

STOP
P004059C