Sie sind auf Seite 1von 1

SEISMIC DESIGN BASE SHEAR

Occupancy Category = (Table 1604.5) II. Other Structures

How to Enter Data

07/08/13 Developed by Forum Engineers

(Sections 1615 to 1617 of The 2003 International Building Code & Section 9.5.5 of The ASCE 7-02)

Seismic Importance Factor, I E = 1.00 Wind Importance Factor, I W = 1.00 Seismic Use Group = I Stiff soil profile = D = = = = = 0.959 D 0.488 D D g g

Site Class = D (Table 1615.1.1) from ICC provided CD: S MS = 143.8 (MCE Spectral Response Acceleration @ 0.2-second Period) from ICC provided CD: S M1 = 73.2 (MCE Spectral Response Acceleration @ 1-second Period)

g% 2/3 times SMS = S DS 4 Seismic Design Category per SDS g% 2/3 times SM1 = S D1 4 Seismic Design Category per SD1 Seismic Design Category per SDS & SD1

(Table 9.5.5.3.1) Coefficient, Cu = 1.40 Basic Resisting System = Lateral Resisting Elements = BmLih wo Bearing Wall System Light frame walls with wood or steel sheathing Response Modification Coefficient System Overstrength Factor Deflection Amplification Factor Numerical Coefficient, Ct Numerical Coefficient, x = = = = = 6 1/2 3 4 0.02 0.75
.. .. ..

R o Cd

Structure Height, h n (ft) = Structure Height Limit (ft) =

26 65

Approximate Fundamental Period, Ta = 0.23 Period per Substantiated Analysis, T 0.32

Second(s) Second(s)

Formula (9.5.5.2.1-1) Formula (9.5.5.2.1-2) Formula (9.5.5.2.1-3)

= = =

S DS / ( R / I ) W S D1 / T / ( R / I ) W 0.044 S DS I W

= 0.147 = 0.326 = 0.042 = 0.147 = 0.105

W W W W W (Eh) (Eh/1.4)

(9.5.5.2.1-1) need not exceed (9.5.5.2.1-2) and shall not be less than (9.5.5.2.1-3) TOTAL DESIGN BASE SHEAR Section 1605.3.2 TOTAL DESIGN BASE SHEAR

Copyright 1994~2004 Forum Engineers. All rights reserved.