Emitting electrode
collecting electrode
Weakest field
Weakest field
Strongest field
25 July 2013
PMI Revision 00
Control loop
Power line
T/R
mA kV
AVC Controller
EPIC III
ESP
- 25/07/2013 - P 2
SPARK RATE
RECOMMENDED :5-10 SPM Field strength is adjusted in such a way that limited sparks takes place. With some sparks/min. , we are able to create more strong field . The outage due to spark is offset by achieving more strong electric field with limited spark. However, if spark is too high then frequent collapse of field will reduce the efficiency and increase the erosion of emitting electrode.
Voltage in KV
SPARK
Time in msec
25 July 2013
PMI Revision 00
components
Automatic voltage control Step-up transformer High-voltage rectifier Sensing device
Corona Power
it depends on Uniformity of Gas velocity Fly Ash: Particle size & Resistivity Voltage Controls: Spark rate setting, Current & voltage limits Plate spacing, Collecting plate & discharge electrode design Frequency & intensity of Rapping
25 July 2013
PMI Revision 00
COMPONENTS OF ACP
ACP Rapping motors Ash level indicator Hopper heater Marshalling box cabinet Opacity monitor