Sie sind auf Seite 1von 4

TOTAL STATION

SOKKIA Total Station Parts


1. Tripod Stand
2. Base Plate
3. Three Leveling Screws
4. Two Arms (Left & Right)
5. Vertical Circle
6. Foxing Screws
Station Centering Foxing Left & Right
Foxing Up
7. Two Bubble Tubes
8. Telescope
9. Eye Piece
10. Object Glass Or Objective
11. Optical Sight Finder Or Collimator
12.Eye Piece for Centering
13.Data out Cable Pin Fixed
14.Marks Of Instruments Height
15.Compass Taker
16.Battery
17.Battery Pocket
18.Foxing Screws Locks
Horizontal calculation of Instruments
Vertical Calculation of Telescope
19.Instrument Handle
20.Display Screen Or Liquid Crystal Display
21.Key Board Numerical / Alphabets Letters
22.Four Arrow Keys Up , Down , Left , Right,
23.Enter Key
24.Four Function Keys F1 , F2 , F3 , F4,
25.Escape Key
26.Bs Key Mean (Back Sight)
27. SFT Key Mean (Shift)
28.FUNC Key Mean ( Function)
Technical Terms and Abbreviation
ZA= Line of Sight / Collimation Axis
Telescope Axis= Line from the Recital to the Center of the Object.

SA= Standing Axis


Vertical Rotation Axis of the Telescope

KA= Tilting Axis


Horizontal Rotation Axis of the Telescope

V= Vertical Angle
VK= Vertical Circle

With Coded Circular Division for Reading V-Angle

Hr= Reflector high above Earth / Ground


H1= Instrument Height above Ground

H2= Horizontal Distance


HK= Horizontal Circle

With the Circular Division for Reading the Hz-Angle

EO= Station Co-Ordinates (Easting)


No= Station Co-Ordinates (Northing)
HO= Station Height

E= Easting of Target Point


N= Northing of Target Point
H= Height of Target Point
Operating the Instruments
Focus
Symbols
Fixed Keys
Alphanumeric Keys
Navigation Keys
Function Keys
Soft Key Bar

Fixed Keys

Page
Menu
User
FNC
Esc
Enter
Trigger Keys
The Measurement Trigger has three Settings (ALL, DIST, OFF)

Soft Keys

ALL DIST REC ENTER ENH


LIST FIND EDM IR/RL PREWIE
NEXT OK

Applications
Surveying
Stake Out
Tie Distance
Area & Volume
Free Station
Reference Line / Arc
Remote Height
Construction
Down Loading
Press F4 for Configuration Open Units (Enter)

Temp
Press
Angle
Distance
Feet Esc

COMMUNICATION (Enter)

Bound Rate = 9600


Data Bit =9
Priority = Even
Stop Bit = 1 Bit Esc Esc

F3 Menu Job

Job Selection All Files Open Select Your Files Open Esc

COMMUNICATION Out Put (Enter)


All Files Open Select You’re Files (Enter)

ProLink Software Use for Total Station


Open Prolink and Go to Options Units Settings
Go to File
Send / Receive File Open
Download / Upload

Das könnte Ihnen auch gefallen