Project Name Revision Approved by LEASE 1ERO CHAP REF ESTIMATE FOR HOUR OF OPERATION CONDITIONS OUTDOOR (OA)

[F] ROOM (RM) [F] DIFFERENCE [F] HORA

DB 95.36 75 20.36 25 906.09

OUT VENTILATION

CFM VENTILATIO SWINGING REVOLVING DOORS OPENS DOORS INFILTRATION CRACK 6

EXH

CFM INFILTRAT CFM OUTDOOR AIR THRU APPARA ESHF ADP ESHF =

INDICATED ADP

TEMP. RISE DESHUM CFM = OUTLET TEMP. DIFF = 8

SUPPLY CFM = BYPASS CFM =

122.95 EFFECTIVE ROOM SENSIBLE HEAT(B 1,08 x TEMP RISE ROOM SENSIBLE HEAT(Btu/hr) 1,08 x DESHUM CFM SUPPLY AIR QUANTITY ROOM SENSIBLE HEAT(Btu/hr) 1,08 x OUTLET TEMP. DIFF SUPPLY CFM - DESHUM CFM

BYPASS CFM =

SUPPLY CFM - DESHUM CFM

RESU Troom TEDB 75 93.55 F + F CFMoa/CFMsupply

TADP TLDB

48 54.83

F + F

B.f

FROM PSYCH. CHART :

TEWD

NOTES

1. USE DRY-BULB (DB) TEMPERATURE DIFFERENCE FROM TOP OF ES 2. USE MOISTURE CONTENT (GR/LB) DIFFERENCE FROM TOP OF EST 3. NORMALLY. USE "CFM VENTILATION" FOR "CFM OUTDOOR AIR" WHEN INFILTRATION IS TO BE OFFSET, REFER TO PAGE 92 TO DE "CFM OUTDOOR AIR." 4. WHEN INFILTRATION IS NOT TO BE OFFSET, AND "CFM VENTILATION "CFM INFILTRATION," THEN THE EXCESS INFILTRAITON IS ACCOUNT * IF THIS DIFF TEMP IS TOO HIGH, DETERMINE SUPPLY CFM FOR DESIRED DIF AIR QUANTITY FORMLA.
#

WHEN BYPASSING MIXTURE OF OUTDOOR AND RETURN AIR, USE SUPPLY C RETURN AIR ONLY, USE DEHUMIFIED CFM.

COOLING L

GYM

TABLE REFERENCE LOCAL TIME SUN TIME PEAK LOAD 8 % RH 80 50 XXX OUTDOOR AIR PEOPLE X 30 SQ FT X 0.1 CFM VENTILATION 0 0 WB 0 0 XXX DP 0 0 XXX CFM/PERSON CFM/SQ FT = GR/LB 206 65.6 140.4 750 90.609 750

PEOPLE CFM/PEOPLE 0 DOOR CFM/DOOR 0 EXHAUST FAN FEET CFM/FEET 0 0 CFM INFILTRATION 0 CFM OUTDOOR AIR THRU APPARATUS 750 APPARATUS DEWPOINT EFFECTIVE ROOM SENSIBLE HEAT(Btu/hr) 0.170 EFFECTIVE ROOM TOTAL HEAT(Btu/hr) 48 F 48 F DEHUMIDFIED AIR QUANTITY X (Troom 0.15 75 F F EFFECTIVE ROOM SENSIBLE HEAT(Btu/hr) CFMDA 823 1,08 x TEMP RISE ROOM SENSIBLE HEAT(Btu/hr) 20 F 1,08 x DESHUM CFM SUPPLY AIR QUANTITY ROOM SENSIBLE HEAT(Btu/hr) CFMSUPPLY 823 1,08 x OUTLET TEMP. DIFF SUPPLY CFM - DESHUM CFM CFMBYPASS

SUPPLY CFM - DESHUM CFM

CFMBYPASS

RESULTING ENT & LVG CONDITIONS AT APPARATUS EDB 0.91 X (TOUTDOOR 95.36 F -

LDB 0.15 X (TEDB 93.55 F -

TLWD

NOTES

PROCEDIMIENTO DE

URE DIFFERENCE FROM TOP OF ESTIMATE FORM. B) DIFFERENCE FROM TOP OF ESTIMATE FORM. LATION" FOR "CFM OUTDOOR AIR" HOWEVER OFFSET, REFER TO PAGE 92 TO DETERMINE M OUTDOOR AIR." E OFFSET, AND "CFM VENTILATION IS LESS THAN XCESS INFILTRAITON IS ACCOUNTED FORHERE. MINE SUPPLY CFM FOR DESIRED DIFFERENCE BY SUPPLY QUANTITY FORMLA.

1. RELLENAR LAS CELDAS UNICAMENTE QUE

2. LA CELDA DEL DATO ES EN LA QUE SE TIE QUE TIENE EL 3. LLENE LOS ESPACIO CONFORME VAYA QUE TIENE EL COLOR ROJO PAR

R AND RETURN AIR, USE SUPPLY CFM WHEN BYPASSING ONLY, USE DEHUMIFIED CFM.

COOLING LOAD CALCULATION SHEET

Prepared by Lacation Sheet N:

CHAP REF HORA LOCAL TIME SUN TIME

TADP 48

[F]

B.f 0.15 3&4 F) 3&7 6 5 48

0 0 0 0 CFM OA

adimensional

AIR QUANTITY - TADP

TUS Troom 75 F) 2&3 TADP 48 F) PROCEDIMIENTO DEL USO DE LA HOJA 1. RELLENAR LAS CELDAS UNICAMENTE QUE TIENEN LA SIGUIENTE FORMA: DATO 6 7 8 7 5 3&7 8 2. LA CELDA DEL DATO ES EN LA QUE SE TIENE QUE INTRODUCIR EL VALOR NUMERICO QUE TIENE EL COLOR AZUL 3. LLENE LOS ESPACIO CONFORME VAYA AVANZANDO Y LEA EL RESULTADO FINAL QUE TIENE EL COLOR ROJO PARA SABER LA CARGA DEL LOCAL 7 F

3&7

Prepared by Lacation Sheet N:

JOSE ALBERTO BALDES

TABLE REFERENCE ITEM AREA OR QUANTITY

SOLAR GAIN-GLASS (Btu/hr) GLASS GLASS GLASS GLASS SKYLIGHT 0 0 0 0 0 SQ FT X SQ FT X SQ FT X SQ FT X SQ FT X

SOLAR & TRANS. GAIN-WALLS & ROOF (Btu/hr) WALL WALL WALL WALL ROOF - SUN ROOF - SHADED 0 0 0 0 0 0 SQ FT X SQ FT X SQ FT X SQ FT X SQ FT X SQ FT X

TRANS. GAIN-EXCEPT WALLS & ROOF (Btu/hr) ALL GLASS PARTITION CEILING FLOOR INFILTRATION 0 426.74 0 0 0 SQ FT X SQ FT X SQ FT X SQ FT X CFM X

INTERNAL SENSIBLE HEAT (Btu/hr) PEOPLE POWER LIGHTS 25 430 1443 RATE METABOLIC WATTS WATTS

APPLIANCE ETC. ADDITIONAL HEAT GAIN

0 0

X X SUB TOTAL 1 ( Btu/hr)

STORE

SQ FT X SUB TOTAL 2 ( Btu/hr)

SAFETY FACTOR

10 ROOM SENSIBLE HEAT (Btu/hr)

SUPPLY DUCT "MAS" SUPPLY DUCT HEAT GAIN % 0 LEAK LOSS % 750 CFM X OUTDOOR AIR EFFECTIVE ROOM SENSIBLE HEAT(Btu/hr) LATENT HEAT (Btu/hr) OUTDOOR AIR PEOPLE STEAM APPLIANCE ETC. ADDITIONAL HEAT GAIN VAPOR TRANS. 750 25 0 0 0 0 CFM X RATE METABOLIC Lbs/hr X X SQ FT X SUB TOTAL 3 ( Btu/hr) SAFETY FACTOR 5 ROOM LATENT HEAT (Btu/hr) SUPPLY AIR DUCT LEAK LOSS 0 750 CFM X OUTDOOR AIR EFFECTIVE ROOM LATENT HEAT(Btu/hr) EFFECTIVE ROOM TOTAL HEAT(Btu/hr) OUTDOOR AIR HEAT (Btu/hr) SENSIBLE LATENT RETURN DUCT HEAT GAIN % HP 750 750 0 0 CFM X CFM X RETURN DUCT + LEAK GAIN % DEHUM. & %

PUMP %

+ PIPE LOSS % SUB TOTAL 4 ( Btu/hr)

GRAND TOTAL HEAT

JOSE ALBERTO BALDES

TABLE REFERENCE SUNGAIN OR TEMP. DIFF FACTOR 0 0 0 0 0 FACTOR 0 0 0 0 0 0 1,782 FACTOR 0 0.3077 0 0 1.08 14,516 325 1467.16 4923.516 BTU/hr BTU/hr BTU/hr

GLASS (Btu/hr) 0 0 0 0 0 BTU/hr X BTU/hr X BTU/hr X BTU/hr X BTU/hr X

-WALLS & ROOF (Btu/hr) 0 0 0 0 0 0 F X F X F X F X F X F X

WALLS & ROOF (Btu/hr) 13.57333333 13.57333333 13.57333333 13.57333333 13.57333333 BTU/hr X F X F X F X F X

BLE HEAT (Btu/hr)

Correction Factor of Appliance Correction Factor of Additional heat gain

0 0 16,298

L 1 ( Btu/hr) 0 X 0

L 2 ( Btu/hr) %

16,298

LE HEAT (Btu/hr) "MAS" 0 20.36 20,401 FAN H.P F X B.f X 0 0.15 1.08

17,928

EAT (Btu/hr) 140.4 GR/lbs X BTU/hr 525 BTU/hr 0 Correction Factor of Appliance Correction Factor of Additional heat gain 140.4 GR/lbs X 0.68

84,729

0 N/A 0 84,729

L 3 ( Btu/hr) %

T HEAT (Btu/hr) % GR/lbs X B.f X

88,965

140.4 99,706

TOTAL HEAT(Btu/hr)

0.15 0.68 120,108 11,084

R HEAT (Btu/hr) 20.36 140.4 0 0 F X B.f X F X B.f X 0.15 1.08 0.15 0.68

0 11,084

L 4 ( Btu/hr)

131,192 11

BTU/hr T.R

EAT