Beruflich Dokumente
Kultur Dokumente
GRID
SAM
GSE
Summary
Page 3 Page 6
Page 10 Page 17 Page 23
GSE
GTW
I/Os
System is
SBUS TBUS LBUS
L1-01-DS Agile System Presentation - Rev G - P 3
Supervision
Maintenance
Summary
Page 3 Page 6
Page 10 Page 17 Page 23
GSE
Visible
DS Agile Operator Interface DS Agile System Management Tool MiCOM C264 Computer MiCOM Ethernet Switches DS Agile GTW (Gateway)
Hidden
DS Agile Agency (Station BUS) DS Agile System Configuration Editor
Tools
DS Agile Equipment Simulator
GSE
NXMU
ES - DS Agile Equipment Simulator CMT - DS Agile Computer Maintenance Tool (for C264)
GSE
Summary
Page 3 Page 6
Page 10 Page 17 Page 23
GSE
1
3xModbus RS485
2 3
IEC-60870-5-101
RS232 Regional center
11HKL
ION7330
13HKL
ION7330
21HKL
12HKL
ION7330
14HKL
ION7330
22HKL
ION7330
WAGO Vesuvius
WAGO Etna
23HKL
ION7330
WAGO Ketelhuis
GSE
OI Server
OI Server
MiCOM C264 Redundancy Internal Synchrocheck Auto Recloser IED Management Advanced automation
L1-01-DS Agile System Presentation - Rev G - P 12
Proxy
Switches
IEC61850.8-1 Station Bus
BCUs
Prot.
BCU
Prot.
SACU WACU
Wired I/O
FO
NMU
Conventional VT&CT NCiT
DMU/ CMU
AMU
Primary Devices
GSE
GSE
WAN Router
Cyber Security
SCADA Gateways
GPS/IEEE1588
C264
P847
P14D Agile
MS3000 CMU
C264
P645
C264
P546
Metering IEC61850
Digital process bus XMU820 MU Agile XMU MU Agile NXMU Circuit Breakers w/mounted COSI-CT COSI-CT
Circuit Breakers
Voltage Transformers
Current Transformers
Circuit Breakers
Voltage Transformers
Current Transformers
COSI-VT
GSE
Summary
Page 3 Page 6
Page 10 Page 17 Page 23
GSE
SBUS
Station BUS (federate all system devices) Except DS Agile SCE for configuration
GSE
Client/Server
Standard/Open N Clients M Servers Optimized traffic Fast Communication
GSE
MiCOM C264
SBUS IED
GSE
Client/Server CLIENT Receive Reports (RP) Send Controls Receive Control Acknowledgements
GSE
Two clients can be selected separately to receive the buffered reports when the connection is back: an OI to display the corresponding events, and trigger alarms if the need arises a GTW to avoid a discrepancy between OI and SCADA
GSE
Summary
Page 3 Page 6
Page 10 Page 17 Page 23
GSE
DS Agile OI, DS Agile SMT MiCOM C264, MiCOM Switches, DS Agile Gateway SBUS Agency, DS Agile SCE, DS Agile ES DS Agile Architectures Distributed Computer Stand alone RTU
Networks SBUS TBUS LBUS Station BUS Tele control BUS Legacy BUS Client/Server protocol (61850) T101, T104, DNP3 ModBus, T103
GSE
Synthesis
BAY INCOMER
MiCOM C264
I/O
IED
TBUS
SCADA
BAY FEEDER 1
BAY FEEDER 2
SITE / SUBSTATION
GSE
www.alstom.com
GRID
GSE
SAM