Master Degree in 1 Year - MSc in Global Management, Project Management Online University of Salford

Ericsson Transmission Network


Discussions Publicits Postes Rechercher Plus...

igroufa, vous aimez ce que vous voyez ici ? Guideline about Traffic Node Ericsson.

Rejoindre ce groupe

Partager la discussion http://lnkd.in/scPNVy

Hello everyone, I'm working in O&M VF I need a guideline about TN. Does somebody know how to integrate a radio-link between two TN's and how to commision a TN. If somebody has some guide I would thank him a lot.
il y a 10 mois Suivre Victor

Dernires nouvelles Tamer Eskander,PMP a rejoint le groupe.

J'aime

Commenter

Suivre

Signaler

Plus

Envoyer un message

il y a 3 heures

19 commentaires Accder aux commentaires les plus rcents

Md. Tarequl Islam a ajout un commentaire dans le groupe sur Link goes down while Main Transmitter is turning off of link (1+1_HSB_SD). : Sorry...Link remains up but Far end contact goes invisible...
J'aime Commenter (1) il y a 6 heures

Suivre Mohmad Junaid

Mohmad Junaid Bhat 1) activate factory settings, if in case the MLTN is in installation mode. 2) configure Basic NE ( for IP/subnet/Gateway/Time ) & then DCN ( OSPF just in case ). 3) start FTP server and check if your MLTN is accessing you software dir via ftp server. 4) upgrade your MLTN baseline to latest version. 5) keep FTP server on and insert MMU into MLTN, wait till BR led stops blinking (which would confirm that software of MMU is now compatible with baseline. 6) connect Radio unit to MMU and wait again if BR starts blinking till its in OFF state. 7) configure radio link under radio links.( you ve to put Modulation scheme which should be same on both the sides, Tx Frequency, power, near end/far end hop IDs, no. of E1 and Channel spacing in case you have MMU2D of MMU2H). thats it, if you need any more clarifications feel free to contact me, I'll be glad if I prove to be of any help. regards/
il y a 10 mois J'aime Signaler comme inappropri

Md. Tarequl Islam participe la discussion : Link goes down while Main Transmitter is turning off of link (1+1_HSB_SD).
J'aime Commenter (1) il y a 7 heures

Voir toutes les nouvelles

Pubs des membres LinkedIn

Review low LTE throughput


Troubleshoot poor LTE performance in 3 easy steps. Free Analyzer w ebinar.

Cliquez pour voir qui a aim ce commentaire.

Mini MBA in London

NOSIRU TAIWO APANPA Thanks Man


il y a 10 mois J'aime Suivre NOSIRU TAIWO 1

Booth ADP program now accepting applications for October session. Apply now

Free Quant Fin Webinar


Paul Wilmott's CQF info sess. Learn practical Quant Fin. Online 5th Sept.

Mohmad Junaid Bhat welcome


il y a 10 mois J'aime Suivre Mohmad Junaid 1

Le choix de l'administrateur Ericsson Transmission Network is now an open group


Yani Hairuddin Tout voir

Statistiques du groupe Victor Monzon Thanks a lot Mohmad. I tried that, but I couldn't do it because I had problem with the management of the node. I didn't get the management and that why I couldn't cofigurate the TN.
il y a 10 mois J'aime Suivre Victor 1
Directeur Manager

DCOUVREZ LES STATISTIQUES


DE CE GROUPE

Jeune diplm

MEMBRES

Suivre Mohmad Junaid

Mohmad Junaid Bhat there is also another easy method of configuring MLTN: get backup file of any other similar MLTN , log in via internet explorer through default IP (USB Connect mode), download backup on the node, and activate, then go to clear reservation and remove all the absent units, then u r good to go
il y a 10 mois J'aime

3 759

Voir les statistiques du groupe

Victor Monzon Mohmad thank a lot, you're very great. In that case, you need to have a TN in management, isn't it? in my case, the TN is a new TN and I don't have it in the MiniLink, also the radiolink between the new one and the other TN doesn't exist.

www.linkedin.com/groups/Guideline-about-Traffic-Node-Ericsson-1108457.S.181213002

1/3

01/09/13
il y a 9 mois J'aime

Guideline about Traffic Node Ericsson. | LinkedIn

Suivre Victor

Mohmad Junaid Bhat you can login a new TN using default ip 10.0.0.1 ( USB Mode erb lan connection ) or 192.168.0.1 ( LAN Mode where laptop IP-192.168.0.2, m255.255.255.248 g-192.168.0.1 )
il y a 9 mois J'aime Suivre Mohmad Junaid

Mohmad Junaid Bhat and thx for the mention...... u r welcome though
il y a 9 mois J'aime Suivre Mohmad Junaid

Panshak Gomos Good one Mohmad.........ur support helped me too.Thnks


il y a 9 mois J'aime Suivre Panshak

Mohmad Junaid Bhat I'm glad to prove of any help to you


il y a 9 mois J'aime Suivre Mohmad Junaid

Panshak Gomos Hi Mohmad, can you help me out with the following problem: I need support for software downgrade for AMM 2P R21 won't accept MMU 2C, what software releases are best suited in case can't get MMU 2D or 2H and how to i set preferences to allow the downgrade??
Suivre Panshak il y a 9 mois J'aime 1

Mohmad Junaid Bhat use R16A30 ...... its most stable for contemporary MMUs like MMU2C/MMU2B/MMU2C4-34.... etc......
il y a 9 mois J'aime Suivre Mohmad Junaid 1

NOSIRU TAIWO APANPA For MMU 2D and MMU 2H I am using R22T18 you can try . I hope its suitable
il y a 9 mois J'aime Suivre NOSIRU TAIWO

Panshak Gomos Thanks Moh' & Taiwo.......great!!


il y a 9 mois J'aime Suivre Panshak

Hashir Mohmad Shah For MMU 2D and MMU 2H, you can use any baseline which is R20A34 above. I would recommend R22B14, using this baseline, your 2D or 2H will work both on -24V and -48V supply. If you are going to use R20A34 or R21A27, then you must provide -48VDC to MLTN. I hope it helps...
Suivre Hashir Mohmad il y a 9 mois J'aime 1

Mohmad Junaid Bhat hey hashir : how about R22G10 or R22T18, they also support -48V/+24V. its not -24V and the guy is actually asking for MMU2C compatibility.... he already has a higher baseline version
il y a 9 mois J'aime

Suivre Mohmad Junaid

Hashir Mohmad Shah hi Mr. junaid, firstly I was replying to the query "which baseline would be best suited for MMU 2H and MMU 2D," and secondly its -24V at the supply

www.linkedin.com/groups/Guideline-about-Traffic-Node-Ericsson-1108457.S.181213002

2/3

01/09/13
source not what we terminate at MLTN.
il y a 9 mois J'aime

Guideline about Traffic Node Ericsson. | LinkedIn

Suivre Hashir Mohmad

Mohmad Junaid Bhat yep thats right then....


il y a 9 mois J'aime Suivre Mohmad Junaid

Panshak Gomos Thanks Guys, been very supportive. My Link is up!!!!


il y a 9 mois J'aime Suivre Panshak

Cliquez pour voir qui a aim ce commentaire.

igroufa, vous aimez ce que vous voyez ici ?

Rejoindre ce groupe

Pubs des membres LinkedIn

MEF CECP Study Guide


Carrier Ethernet Professionals - Get the NEW MEF-CECP Study Guide!

EM Optical Transmitter
Make fiber optic products for the CATV,Telecommunications, FTTH

Assistance clientle Types de comptes

propos

Presse

Blog

Carrires

Publicit

Talent Solutions

Outils

Mobile

Dveloppeurs

diteurs de contenu

Langue

LinkedIn Corporation 2013 Envoyer feedback

Conditions gnrales d'utilisation de LinkedIn

Politique de confidentialit

Directives de la communaut

Politique relative aux cookies

Politique de copyright

www.linkedin.com/groups/Guideline-about-Traffic-Node-Ericsson-1108457.S.181213002

3/3

Das könnte Ihnen auch gefallen