LISTA DE PARAMETROS DEL VARIADOR POWER FLEX 75 HP

Programming and Parameters


Basic Display Group
Parameter
b001 b002 b003 b004 b005 b006 b007 b008 b010 b011 b012 b013 b014 b015

Description
Output Freq Commanded Freq Output Current Output Voltage DC Bus Voltage Drive Status Fault 1 Code Process Display Output Power Elapsed MWh Elapsed Run Time Torque Current Drive Temp Elapsed kWh

Value
Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only

Programming and Parameters


Basic Program Group
Parameter
P031 P032 P033 P034 P035 P036 P037 P038 P039 P040 P041 P042 P043

Description
Motor NP Volts Motor NP Hertz Motor OL Current Minimum Freq Maximum Freq Start Source Stop Mode Speed Reference] Accel Time 1 Decel Time 1 Reset To Defalts Auto Mode Motor OL Ret

Value
440VAC 60 HZ 88 AMP 30.0 HZ 60.0 HZ 0 Keypad 5 Coast 3 Analog In 2 10.00 Secs 10.00 Secs 0 Ready/Idle 2 Auto/Manual
0 Disabled (Default)

Programming and Parameters


Terminal Block Group
Parameter T051 T052 T053 T054 T055 T056 T058 T059 T060 T061 T063 T064 T065 T066 T068 T069 T070 T071 T072 T073 T074 T075 T076 T077 T078 T079 T080 T081 T082 T083 T084 T085 T086 T087 T088 T089 Description Digital In1 Sel Digital In2 Sel Digital In3 Sel Digital In4 Sel Relay Out1 Sel Relay Out1 Level Relay 1 On Time Relay 1 Off Time Relay Out2 Sel Relay Out2 Level Relay 2 On Time Relay 2 Off Time Opto Out Sel Opto Out Level Opto Out Logic Analog In 1 Sel Analog In 1 Lo Analog In 1 Hi Analog In 1 Loss Analog In 2 Sel Analog In 2 Lo] Analog In 2 Hi Analog In 2 Loss Sleep-Wake Sel Sleep Level Sleep Time Wake Level Wake Time Analog Out1 Sel Analog Out1 High [Anlg Out1 Setpt Analog Out2 Sel Analog Out2 High Anlg Out2 Setpt Anlg Loss Delay Analog In Filter Value 2 Auto Mode 0 Not Used 0 Not Used 3 Local 2 MotorRunning 0.0 0.0 Secs 0.0 Secs 4 Motor Overld 0.0 0.0 Secs 0.0 Secs
1 At Frequency (Default)

0.0 0 N.A. 0-10V 0.0% 100.0%


0 Disabled (Default)

4-20 mA 0.0% 100.0%


0 Disabled (Default) 0 Disabled (Default)

10.0% 0.0 Secs 15.0% 0.0 Secs 15 OutCurr 4-20 100% 0.0% 15 OutCurr 4-20 100% 0.0% 0.0 Secs 0

Programming and Parameters


Communications Group
Parameter C101 C102 C103 C104 C105 C106 C107 C108 C109 Description Language Comm Format] Comm Data Rate Comm Node Addr Comm Loss Action Comm Loss Time Comm Write Mode Start Source 2 Speed Ref 2 Value 3 Espaol 0 RTU 8-N-1 3 9600 100 0 Fault 5.0 Secs 0 Save 5 Comm Port 5 Comm Port

Programming and Parameters


Advanced Program Group
Parameter
A141 A142 A143 A144 A145 A146 A147 A148 A149 A150 A151 A152 A153 A154 A155 A156 A157 A158 A159 A160 A163 A164 A165 A166 A167 A168 A169 A170 A171 A172 A173 A174 A175 A176 A177 A178 A179 A180

Description
Purge Frequency Internal Freq] Preset Freq 0 Preset Freq 1 Preset Freq 2 Preset Freq 3 Accel Time 2 Decel Time 2] S Curve % PID Trim Hi PID Trim Lo PID Ref Sel PID Feedback Sel PID Prop Gain PID Integ Time PID Diff Rate PID Setpoint PID Deadband PID Preload Process Factor Auto Rstrt Tries Auto Rstrt Delay Start At PowerUp Reverse Disable Flying Start En PWM Frequency PWM Mode Boost Select Start Boost Break Voltage Break Frequency Maximum Voltage] Slip Hertz @ FLA DC Brake Time DC Brake Level] DC Brk Time@Strt Current Limit 1 Current Limit 2

Value
5.0 Hz 60.00 Hz 0.0 Hz 5.0 Hz 10.0 Hz 20.0 Hz 30.00 Secs 30.00 Secs 20% 60.0 Hz 0.0 Hz 2 Analog In 1 0 Analog In 1 1.00 2.0 Secs 0.00 (1/Secs) 0.0% 0.0% 0.0 Hz 30.0 0 1.0 Secs 0 Disabled 0 Rev Enabled 0 Disabled 4.0 kHz 0 Space Vector 4 45.0, VT 2.5% 25.0% 15.0 Hz 470VAC 2.0 Hz 0.0 Secs 7.1A x 0.05 0.0 Secs 156.2A 1.1 156.2A 1.1

A181 A182 A183 A184 A185 A186 A187 A188 A189 A190 A191 A192 A193 A194 A195 A196 A197 A198 A199 A200 A201 A202

Motor OL Select Drive OL Mode SW Current Trip] Load Loss Level] Load Loss Time Stall Fault Time Bus Reg Mode Skip Frequency 1 Skip Freq Band 1 Skip Frequency 2 Skip Freq Band 2 Skip Freq Band 3 Skip Freq Band 3 Compensation Reset Meters Testpoint Sel Fault Clear Program Lock] Motor NP Poles Motor NP FLA PID Invert Error MOP Reset Sel

0 No Derate Both-PWM 1st 0.0 Amp 0.0 Amp 0 Secs 0 60 Seconds 1 Enabled 0 Hz 0.0 Hz 0 Hz 0.0 Hz 0 Hz 0.0 Hz 1 Electrical 0 Ready/Idle O400 0 Ready/Idle 0 Unlocked 4 poles 88 Amp 0 Not Inverted 1 Save MOP Ref

Programming and Parameters


Advanced Display Group
Parameter
d301 d302 d303 d304 d305 d306 d307 d308 d309 d310 d311 d312 d313 d314 d315 d316 d317 d318 d319 d320 d321 d322 d323 d324 d325 d326 d327 d328 d329 d330 d331 d332 d333 d334 d335 d336 d337 d338

Value

Description
Control Source Contrl In Status Comm Status PID Setpnt Disp1 Analog In 1 Analog In 2 Fault 1 Code Fault 2 Code Fault 3 Code Fault 1 Time-hr Fault 1 Time-min Fault 2 Time-hr Fault 2 Time-min Fault 3 Time-hr Fault 3 Time-min Elapsed Time-hr Elapsed Time-min Output Powr Fctr Testpoint Data Control SW Ver Drive Type Output Speed Output RPM Fault Frequency Fault Current Fault Bus Volts Status @ Fault PID Fdbk Display DC Bus Ripple V Fault 4 Code Fault 5 Code Fault 6 Code Fault 7 Code Fault 8 Code Fault 9 Code Fault 10 Code Fault 4 Time-hr Fault 4 Time-min Read Only Read Only Read Only 0.0% 0.0% 0.0% Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only 0.0% Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only

d339 d340 d341 d342 d343 d344 d345 d346 d347 d348 d349 d350

Fault 5 Time-hr Fault 5 Time-min Fault 6 Time-hr [Fault 6 Time-min Fault 7 Time-hr Fault 7 Time-min Fault 8 Time-hr Fault 8 Time-min Fault 9 Time-hr Fault 9 Time-min Fault10 Time-hr Fault10 Time-min

Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only