Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH Phase System Wire Wire Size 3 3 + GND 8 3 3 + GND 14 Amps 32 16 Breaker 40 20

Drain Requirements
FRONT
Flow Rate (@45PSI/3Bar) gal/min liter/min 30 113 Minimum Supply Line Size US Metric 1-1/4 DN 32 Max Operating Pressure US Metric 125 PSI 8 Bar Max Operating Pressure US Metric 100 PSI 6 Bar
Dynamic pressure kN/m2 lbs/ft2 74 3.5 Dynamic Frequency Hz 12.08
BY

Connection Size inches mm 4 102

Discharge Rate gal/min liters/min 150 560

Min Sewer Line inches mm 5 127

Water Requirements
Connection Size US Metric 1" DN 25 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1" DN 25 30-75 2-5 Minimum Supply Line Size US Metric 1" DN 19

Dynamic Load Specifications


Static floor load kN lbs 22.64 5089 Static pressure kN/m2 lbs/ft2 178 8.5 Total Dynamic Load kN lbs 9.4 2116