This alarm is reported when the difference between the RTWP of the main RX channel and the RTWP of the diversity RX channel exceeds 10 dB.
Possible Causes
The setting of attenuation on the RX channel of the RF unit is incorrect. External interferences exist on the main or diversity antenna of the RF unit. The feeder connected to the RF unit is faulty..
Handling Procedure
1- Check the parameter settings of the RF unit >>>>>>"check with BO" 2- Reconnect the jumper to the antenna port of the RF unit on site>>>>>>>>"FM task"
3- Power off the RF unit on site and then power it on>>>>>>>>"FM task" 4- Escalate to RF team to start the frequency scanning test. >>>>>>>>"RF team"