GERAN

Commands
Base Station Controller


CML:BSC
A30808-X3247-M230-6-7619



2 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
Copyright (C) Siemens AG 2006
Issued by the Communications Group
Hofmannstrae 51
D-81359 Mnchen
Technical modifications possible.
Technical specifications and features are binding only insofar as
they are specifically and expressly agreed upon in a written contract.
Copyright (C) Siemens AG 2006
Issued by the Communications Group
Hofmannstrae 51
D-81359 Mnchen
Technical modifications possible.
Technical specifications and features are binding only insofar as
they are specifically and expressly agreed upon in a written contract.
f Important Notice on Product Safety
DANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system must
comply with the applicable safety standards.
Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components may
also have high operating temperatures.
Failure to observe and follow all installation and safety instructions can result in serious personal injury
or property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
LEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Alle an das System angeschlossenen
Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.
In diesen Anlagen stehen die Netzversorgungsleitungen unter gefhrlicher Spannung. Einige Komponenten
knnen auch eine hohe Betriebstemperatur aufweisen.
Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Krperverletzungen oder
Sachschden fhren.
Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten.
Caution:
This equipment has been tested and found to comply with EN 301489. Its class of conformity is defined in table
A30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accor-
dance with the relevant standards referenced in the manual Guide to Documentation, may cause harmful inter-
ference to radio communications.
For system installations it is strictly required to choose all installation sites according to national and local require-
ments concerning construction rules and static load capacities of buildings and roofs.
For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagnetic
field / force (EMF) limits. Otherwise harmful personal interference is possible.
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their own purposes
could violate the rights of their owners.


A30808-X3247-M230-6-7619

3
CML:BSC
Id:0900d805800cef81
Table of Contents
This document has 2207 pages.
Reason for Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1.1 Structure of the Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1.2 Structure of the Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1.3 Command Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
1.4 Graphical User Interface (GUI) Representation of the LMT Evolution . . . . 57
1.4.1 Start LMT Evolution Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1.4.2 LMT Evolution Windows for GET, CREATE, SET,...., Commands. . . . . . . 59
1.5 LMT BSC Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1.5.1 BSC Containment Tree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1.5.2 BTS Equipment and TRAU Containment Sub-Trees . . . . . . . . . . . . . . . . . 64
1.5.3 Alphabetical List of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
2 Objects and Commands in Alphabetical Order. . . . . . . . . . . . . . . . . . . . . 108
ADJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
CREATE ADJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
DELETE ADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
GET ADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
GET ADJC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
SET ADJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
CREATE ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
DELETE ADJC3G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
GET ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
GET ADJC3G BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
SET ADJC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
BRIDGE BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
GET BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
GET BSC ALARMSEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
GET BSC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
GET BSC CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
GET BSC FLAGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
GET BSC TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
GET BSC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
GETLOCKED BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
MEMDUMP BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
SET BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
GET BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
GET BSCE ALARMSEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
GET BSCE BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173


4 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
GET BSCE REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
GETACTIVEALARMS BSCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
PERFTEST BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
SET BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
STOPTEST BSCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
BSCESUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
GET BSCESUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
GET BSCESUDB BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
GET BSCESUDB STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
GETINFO BSCESUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
BSCESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
GET BSCESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
GET BSCESUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
GET BSCESUSW STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
GETINFO BSCESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
BSCETEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
GET BSCETEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
GET BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
GET BSCOSUDB BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
GETINFO BSCOSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
SAVEDB BSCOSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
SET BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
SETRUNNEW BSCOSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
GET BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
GET BSCOSUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
GETINFO BSCOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
SET BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
SETBACKNEW BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
SETRUNBACK BSCOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
SETRUNNEW BSCOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
CREATE BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
DELETE BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
GET BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
GET BTS ADM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
GET BTS AMRPARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
GET BTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
GET BTS CCCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
GET BTS CELLFREQDEFINITION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
GET BTS INTERF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
GET BTS OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
GET BTS SERVICE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
GET BTS TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281


A30808-X3247-M230-6-7619

5
CML:BSC
Id:0900d805800cef81
GET BTS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
GETINFO BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
GETRELATIONSHIP BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
GETSUBO BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
LOCK BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
MONITOR BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
SET BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
SHUTDOWN BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
UNLOCK BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
CREATE BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
DELETE BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
GET BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
GET BTSM BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
GET BTSM STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
GETINFO BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
GETRELATIONSHIP BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
GETSUBO BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
LOCK BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
SET BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
SHUTDOWN BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
UNLOCK BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
BTSMOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
GET BTSMOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
GET BTSMOSUSW BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
GETINFO BTSMOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
SETRUNBACK BTSMOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
CREATE CBCL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
DELETE CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
GET CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
GET CBCL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
GET CBCL X25INFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
GET CBCL STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
GETRELATIONSHIP CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
LOCK CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
UNLOCK CBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
CBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368
CREATE CBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368
DELETE CBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
GET CBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
GET CBTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
GETINFO CBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
SET CBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385


6 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
CFHSY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
CREATE CFHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
DELETE CFHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
GET CFHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
GET CFHSY BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
SET CFHSY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
CREATE CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
DELETE CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
GET CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
GET CHAN BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
GET CHAN STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
GETRELATIONSHIP CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
GETSUBO CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
LOCK CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
SET CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
SHUTDOWN CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
UNLOCK CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
CPCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419
CREATE CPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419
DELETE CPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
GET CPCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422
GET CPCU BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425
SET CPCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427
CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
GET CPEX STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
GETRELATIONSHIP CPEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431
GETSUBO CPEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431
GETTEST CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432
LOCK CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
PERFTEST CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
STOPTEST CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
UNLOCK CPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438
CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
GET CTRCO STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
GETINFO CTRCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440
LOCK CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
UNLOCK CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443
UPLALLCELLTR CTRCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444
UPLCELLTR CTRCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445
CTRSCHED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446
CREATE CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446
DELETE CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 447
GET CTRSCHED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
GET CTRSCHED BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450


A30808-X3247-M230-6-7619

7
CML:BSC
Id:0900d805800cef81
GET CTRSCHED STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
LOCK CTRSCHED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
SET CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452
UNLOCK CTRSCHED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 455
FORMAT DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 455
GET DISK STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456
GETRELATIONSHIP DISK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
GETSUBO DISK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
GETTEST DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
LOCK DISK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459
PERFTEST DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460
STOPTEST DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462
UNLOCK DISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
DK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465
GET DK40 STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465
GETRELATIONSHIP DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
GETSUBO DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
GETTEST DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467
LOCK DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
PERFTEST DK40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
STOPTEST DK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471
UNLOCK DK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473
ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474
CREATE ENVA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474
DELETE ENVA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
GET ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
GET ENVA BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 477
GET ENVA STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
LOCK ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
SET ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
UNLOCK ENVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
CREATE EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
DELETE EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483
GET EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484
GET EPWR STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484
GETSUBO EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 485
GETTEST EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486
LOCK EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 487
PERFTEST EPWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 488
STOPTEST EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
UNLOCK EPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 492
ES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493
GET ES STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493


8 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
GETINFO ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494
GETRELATIONSHIP ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 498
GETSUBO ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
GETTEST ES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
LOCK ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
PERFTEST ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
STOPTEST ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
UNLOCK ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505
FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507
GET FAN STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507
GETRELATIONSHIP FAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
GETSUBO FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 508
FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
CREATE FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510
DELETE FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512
GET FHSY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513
GET FHSY BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514
SET FHSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515
FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518
COPY FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518
CREATEDIR FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519
DELETE FILEHANDLER GENFILE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 520
DIR FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 521
FILECOM FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522
FILEDECOM FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523
MOVE FILEHANDLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523
REMOVEDIR FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525
UPLPRLOG FILEHANDLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 526
FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527
CREATE FRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527
DELETE FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529
GET FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 530
GET FRL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531
GET FRL STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 532
GETINFO FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533
GETRELATIONSHIP FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536
GETSUBO FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536
LOCK FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 537
SET FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 538
UNLOCK FRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540
GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
CREATE GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
DELETE GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
GET GBIPLNK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542
GET GBIPLNK STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543


A30808-X3247-M230-6-7619

9
CML:BSC
Id:0900d805800cef81
GETRELATIONSHIP GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544
GETSUBO GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545
LOCK GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 546
UNLOCK GBIPLNK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 546
HAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548
GET HAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548
GET HAND BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567
GET HAND DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 570
SET HAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 571
HDCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583
CREATE HDCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583
DELETE HDCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584
GET HDCTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 585
GET HDCTR BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 586
GET HDCTR STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 586
GETINFO HDCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 587
LOCK HDCTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589
SET HDCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 590
UNLOCK HDCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591
UPLHDCTR HDCTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 592
IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594
CREATE IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594
DELETE IPLI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595
GET IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 596
GET IPLI BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598
GET IPLI STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 598
GETINFO IPLI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599
GETRELATIONSHIP IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601
PING IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602
SET IPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603
IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
GET IXLT STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
GETINFO IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606
GETRELATIONSHIP IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 608
GETTEST IXLT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609
LOCK IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610
PERFTEST IXLT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611
STOPTEST IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 613
UNLOCK IXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614
LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
CREATE LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
DELETE LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617
GET LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 618
GET LICD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
GET LICD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621


10 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
GETINFO LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621
GETRELATIONSHIP LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 625
GETSUBO LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 626
GETTEST LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 626
LOCK LICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 628
PERFTEST LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 628
SET LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631
STOPTEST LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 632
UNLOCK LICD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633
LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635
CREATE LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635
DELETE LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 636
GET LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637
GET LICDS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638
GETRELATIONSHIP LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639
GETSUBO LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640
GETTEST LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640
LOCK LICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 642
PERFTEST LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 642
STOPTEST LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645
UNLOCK LICDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
LMT-INTERNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648
ECHO LMT-INTERNAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648
EXEC LMT-INTERNAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648
SET LMT-INTERNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649
LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651
CREATE LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651
DELETE LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652
GET LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 653
GET LPDLM BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 654
GET LPDLM STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 655
GETINFO LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 656
GETRELATIONSHIP LPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 658
GETSUBO LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 659
SET LPDLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 660
LPDLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 661
GET LPDLR STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 661
GETINFO LPDLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 662
GETRELATIONSHIP LPDLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664
GETSUBO LPDLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665
LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666
CREATE LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666
DELETE LPDLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667
GET LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 668
GET LPDLS BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 669


A30808-X3247-M230-6-7619

11
CML:BSC
Id:0900d805800cef81
GET LPDLS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670
GETINFO LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670
GETRELATIONSHIP LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
GETSUBO LPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674
SET LPDLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674
MEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 676
GET MEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 676
GET MEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 677
GET MEL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 678
SET MEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 678
MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 680
GET MEMT STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 680
GETRELATIONSHIP MEMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681
GETSUBO MEMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681
GETTEST MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 682
LOCK MEMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683
PERFTEST MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684
STOPTEST MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686
SWITCH MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
UNLOCK MEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690
GET MPCC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690
GETINFO MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691
GETRELATIONSHIP MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 693
GETSUBO MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694
GETTEST MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695
LOCK MPCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 696
PERFTEST MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 697
STOPTEST MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 699
SWITCH MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701
UNLOCK MPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701
NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703
GET NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703
GET NEYESUSW BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 704
GET NEYESUSW STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705
GETINFO NEYESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706
NEDOWNLOAD NEYESUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708
NEDOWNLOADABO NEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710
NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712
CREATE NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712
DELETE NSVC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713
GET NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714
GET NSVC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715
GET NSVC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716
GETINFO NSVC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716


12 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
GETRELATIONSHIP NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 718
GETSUBO NSVC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 719
LOCK NSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 720
UNLOCK NSVC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
NSVCIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723
GET NSVCIP STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723
GETRELATIONSHIP NSVCIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724
GETSUBO NSVCIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 725
NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726
CREATE NSVLIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726
DELETE NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727
GET NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 728
GET NSVLIP BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 729
GET NSVLIP STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 729
GETRELATIONSHIP NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730
GETSUBO NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731
LOCK NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732
SET NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733
UNLOCK NSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734
NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 736
FORCSYNC NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 736
GET NTW STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737
GETRELATIONSHIP NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737
GETSUBO NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738
GETSYNC NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
GETTEST NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 741
LOCK NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 742
PERFTEST NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 743
STOPTEST NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745
SWITCH NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746
UNLOCK NTW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747
UPDATETUNE NTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 748
NUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 751
CREATE NUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 751
DELETE NUC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753
GET NUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753
GET NUC BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754
GET NUC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 755
GETRELATIONSHIP NUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756
OMAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
CREATE OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 758
DELETE OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759
GET OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 760
GET OMAL BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 761
GET OMAL X25INFO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762


A30808-X3247-M230-6-7619

13
CML:BSC
Id:0900d805800cef81
GET OMAL STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762
GETRELATIONSHIP OMAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764
GETSUBO OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 765
SET OMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 765
OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 767
CREATE OPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 767
DELETE OPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 772
GET OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 773
GET OPC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 781
GET OPC MTL2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782
GET OPC MTL3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 783
GETINFO OPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784
SET OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 787
PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793
CREATE PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793
DELETE PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 795
GET PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 796
GET PCMA BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 799
GET PCMA PCM24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 799
GET PCMA PCM30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
GET PCMA STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801
GETINFO PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801
GETRELATIONSHIP PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803
GETSUBO PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804
LOCK PCMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805
SHUTDOWN PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806
UNLOCK PCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 807
PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 809
CREATE PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 809
DELETE PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 811
GET PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 812
GET PCMB BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 815
GET PCMB PCM24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 816
GET PCMB PCM30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 816
GET PCMB STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 817
GETINFO PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 818
GETREDSTAT PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 822
GETRELATIONSHIP PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 823
GETSUBO PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 824
LOCK PCMB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 825
SET PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 826
UNLOCK PCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 828
PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 830
CREATE PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 830
DELETE PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 832


14 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
GET PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 832
GET PCMG BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 835
GET PCMG PCM24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 835
GET PCMG PCM30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 836
GET PCMG STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 837
GETINFO PCMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 838
GETRELATIONSHIP PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 841
GETSUBO PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 842
LOCK PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 843
SET PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 844
UNLOCK PCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 845
PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 847
CREATE PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 847
DELETE PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 849
GET PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 850
GET PCMS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 852
GET PCMS PCM24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 853
GET PCMS PCM30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 854
GET PCMS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 854
GETINFO PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855
GETREDSTAT PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 859
GETRELATIONSHIP PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 860
GETSUBO PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 861
LOCK PCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 862
SET PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 863
UNLOCK PCMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 864
PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 866
CREATE PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 866
DELETE PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 869
GET PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 870
GET PCU BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874
GET PCU STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 876
GETINFO PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 877
GETRELATIONSHIP PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 884
GETSUBO PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 885
LOCK PCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 885
SET PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 887
UNLOCK PCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 890
PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 892
GET PPXL STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 892
GETINFO PPXL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 893
GETRELATIONSHIP PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 897
GETSUBO PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 898
GETTEST PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 899
LOCK PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900
PERFTEST PPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901


A30808-X3247-M230-6-7619

15
CML:BSC
Id:0900d805800cef81
STOPTEST PPXL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 903
UNLOCK PPXL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 905
PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907
GET PPXU STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907
GETINFO PPXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 908
GETRELATIONSHIP PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 911
GETSUBO PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 912
GETTEST PPXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 912
LOCK PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914
PERFTEST PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 915
STOPTEST PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 917
UNLOCK PPXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 918
PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 920
CREATE PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 920
DELETE PTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 934
GET PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 936
GET PTPPKF BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 951
GET PTPPKF STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 956
GETINFO PTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 957
GETRELATIONSHIP PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 961
GETSUBO PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 962
LOCK PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 963
SET PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 965
UNLOCK PTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 978
PWRC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 980
GET PWRC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 980
GET PWRC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 995
SET PWRC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 997
PWRD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1002
GET PWRD STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1002
GETRELATIONSHIP PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1003
GETSUBO PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1003
GETTEST PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1004
LOCK PWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1005
PERFTEST PWRD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1006
STOPTEST PWRD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1008
UNLOCK PWRD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1010
QSMONBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1011
CREATE QSMONBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1011
DELETE QSMONBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1012
GET QSMONBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1012
GET QSMONBSC BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1013
GET QSMONBSC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1014
GETCURRENTVALUE QSMONBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . 1015
LOCK QSMONBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1016


16 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
SET QSMONBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1017
UNLOCK QSMONBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1018
QSMONBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1019
CREATE QSMONBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1019
DELETE QSMONBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1020
GET QSMONBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1021
GET QSMONBTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1022
GET QSMONBTS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1023
GETCURRENTVALUE QSMONBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024
LOCK QSMONBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1025
SET QSMONBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1026
UNLOCK QSMONBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1027
QSMONBTSCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1029
GETINFO QSMONBTSCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1029
QSMONGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1031
CREATE QSMONGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1031
DELETE QSMONGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1032
GET QSMONGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1033
GET QSMONGPRS BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1034
GET QSMONGPRS STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1035
GETCURRENTVALUE QSMONGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . 1035
LOCK QSMONGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1036
SET QSMONGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1037
UNLOCK QSMONGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1038
QSMONGPRSCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040
GETINFO QSMONGPRSCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040
QSTHRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1042
CREATE QSTHRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1042
DELETE QSTHRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1043
GET QSTHRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1044
GET QSTHRS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1045
GETINFO QSTHRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1045
SET QSTHRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1048
REMINV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1050
ALIGN REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1050
DNLIDFD REMINV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1051
GET REMINV STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1052
LOCK REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1054
UNLOCK REMINV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1054
UPLCIDF REMINV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1055
UPLLIDF REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1057
RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1059
CREATE RFLOOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1059
DELETE RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1060


A30808-X3247-M230-6-7619

17
CML:BSC
Id:0900d805800cef81
GET RFLOOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1061
GET RFLOOP BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1062
GET RFLOOP STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1063
LOCK RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1064
SET RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1065
UNLOCK RFLOOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1066
UPLOADREQ RFLOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1067
RNSVLIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1069
CREATE RNSVLIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1069
DELETE RNSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1070
GET RNSVLIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1071
GET RNSVLIP BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1072
SET RNSVLIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1073
RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1075
CREATE RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1075
DELETE RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1076
GET RSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1077
GET RSUDB BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1079
GET RSUDB STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1080
SET RSUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1081
UPLDFILE RSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1082
RSUEXE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1084
CREATE RSUEXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1084
DELETE RSUEXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1086
GET RSUEXE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1087
GET RSUEXE BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1089
GET RSUEXE STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1089
RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1091
CREATE RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1091
DELETE RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1094
GET RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1095
GET RSUPCH BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1097
GET RSUPCH STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1098
LOADPATCH RSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1099
SET RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100
UNLOADPCH RSUPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1102
RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1104
CREATE RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1104
DELETE RSUSWLH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1106
GET RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1107
GET RSUSWLH BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1109
GET RSUSWLH STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1109
SET RSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1110
SCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1112
CREATE SCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1112


18 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
DELETE SCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1115
GET SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1116
GET SCA BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1128
GET SCA EICM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1129
GET SCA NMDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1129
GET SCA STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1130
LOCK SCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1131
SET SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1132
UNLOCK SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1133
UPLOADREQ SCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1134
SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1136
ADD SCANBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1136
CREATE SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1137
DELETE SCANBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1139
GET SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1140
GET SCANBSC BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1142
GET SCANBSC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1142
GETCURRENTVALUES SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1143
LOCK SCANBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1144
REMOVE SCANBSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1145
SET SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1146
UNLOCK SCANBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1148
SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1149
ADD SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1149
CREATE SCANBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150
DELETE SCANBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1152
GET SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1153
GET SCANBTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1155
GET SCANBTS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1156
GETCURRENTVALUES SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1157
LOCK SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1158
REMOVE SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1159
SET SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1160
UNLOCK SCANBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1162
SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1163
ADD SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1163
CREATE SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1164
DELETE SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1166
GET SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1167
GET SCANBTSE BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1169
GET SCANBTSE STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1170
LOCK SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1170
REMOVE SCANBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1171
SET SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1172
UNLOCK SCANBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1174


A30808-X3247-M230-6-7619

19
CML:BSC
Id:0900d805800cef81
SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1176
ADD SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1176
CREATE SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1177
DELETE SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1179
GET SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1180
GET SCANBTSIHO BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1182
GET SCANBTSIHO STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1183
GETCURRENTVALUES SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . 1184
LOCK SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1185
REMOVE SCANBTSIHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1186
SET SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1187
UNLOCK SCANBTSIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1189
SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1191
ADD SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1191
CREATE SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1192
DELETE SCANBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1194
GET SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1195
GET SCANBTSM BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1197
GET SCANBTSM STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1198
LOCK SCANBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1198
REMOVE SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1199
SET SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
UNLOCK SCANBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1202
SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1204
ADD SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1204
CREATE SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1205
DELETE SCANBTSOHOI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1207
GET SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1208
GET SCANBTSOHOI BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1210
GET SCANBTSOHOI STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1211
GETCURRENTVALUES SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . 1212
LOCK SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1213
REMOVE SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1214
SET SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1215
UNLOCK SCANBTSOHOI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1217
SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1219
ADD SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1219
CREATE SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1220
DELETE SCANBTSOHON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1222
GET SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1223
GET SCANBTSOHON BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1225
GET SCANBTSOHON STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1226
GETCURRENTVALUES SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . 1227
LOCK SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1228
REMOVE SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1229
SET SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1230


20 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
UNLOCK SCANBTSOHON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1232
SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1234
ADD SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1234
CREATE SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1235
DELETE SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1237
GET SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1238
GET SCANBTSOHOS BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1240
GET SCANBTSOHOS STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1241
GETCURRENTVALUES SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . 1242
LOCK SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1243
REMOVE SCANBTSOHOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1244
SET SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1245
UNLOCK SCANBTSOHOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1247
SCANCHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1248
ADD SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1248
CREATE SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1249
DELETE SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1251
GET SCANCHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1252
GET SCANCHAN BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1254
GET SCANCHAN STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1255
LOCK SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1255
REMOVE SCANCHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1256
SET SCANCHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1257
UNLOCK SCANCHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1259
SCANCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1261
GETINFO SCANCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1261
UPLMEAS SCANCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1263
SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1265
ADD SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1265
CREATE SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1266
DELETE SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1268
GET SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1269
GET SCANCTRX BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1271
GET SCANCTRX STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1272
LOCK SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1273
REMOVE SCANCTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1273
SET SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1274
UNLOCK SCANCTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1276
SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1278
ADD SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1278
CREATE SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1279
DELETE SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1281
GET SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1282
GET SCANFBTSM BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1284
GET SCANFBTSM STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1285


A30808-X3247-M230-6-7619

21
CML:BSC
Id:0900d805800cef81
GETCURRENTVALUES SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . 1286
LOCK SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1287
REMOVE SCANFBTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1288
SET SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1289
UNLOCK SCANFBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1291
SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1293
ADD SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1293
CREATE SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1294
DELETE SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1296
GET SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1297
GET SCANGPRS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1299
GET SCANGPRS STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1300
GETCURRENTVALUES SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . 1300
LOCK SCANGPRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1302
REMOVE SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1303
SET SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1304
UNLOCK SCANGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1306
SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1307
ADD SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1307
CREATE SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1308
DELETE SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1310
GET SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1311
GET SCANSS7L BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1313
GET SCANSS7L STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1314
GETCURRENTVALUES SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . 1315
LOCK SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1316
REMOVE SCANSS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1317
SET SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1318
UNLOCK SCANSS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1320
SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1321
ADD SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1321
CREATE SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1322
DELETE SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1324
GET SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1325
GET SCANTRX BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1327
GET SCANTRX STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1328
GETCURRENTVALUES SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1328
LOCK SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1330
REMOVE SCANTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1331
SET SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1332
UNLOCK SCANTRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1334
SOFTWARE-MANAGEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1335
DNLFILE SOFTWARE-MANAGEMENT. . . . . . . . . . . . . . . . . . . . . . . . . 1335
LOADMPCC SOFTWARE-MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . 1336
UPLBTSLOG SOFTWARE-MANAGEMENT . . . . . . . . . . . . . . . . . . . . . 1337


22 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
UPLBTSTDLOG SOFTWARE-MANAGEMENT . . . . . . . . . . . . . . . . . . . 1339
UPLFILE SOFTWARE-MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . 1340
UPLTRAULOG SOFTWARE-MANAGEMENT . . . . . . . . . . . . . . . . . . . . 1341
SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1344
CREATE SS7L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1344
DELETE SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1345
GET SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1346
GET SS7L BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1347
GET SS7L STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1348
GETRELATIONSHIP SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1349
GETSUBO SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1350
INHIBIT SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1351
LOCK SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1352
TESTLINK SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1353
UNINHIBIT SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1354
UNLOCK SS7L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1355
SS7S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1357
GET SS7S STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1357
GETSUBO SS7S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1358
SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1359
CREATE SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1359
DELETE SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1360
GET SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1361
GET SUBTSLB BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1362
GET SUBTSLB STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1363
GETRELATIONSHIP SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1364
LOCK SUBTSLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1365
SHUTDOWN SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1365
UNLOCK SUBTSLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1366
SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1368
CREATE SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1368
DELETE SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1369
GET SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1369
GET SYNC BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1371
GET SYNC STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1371
GETRELATIONSHIP SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1372
GETSUBO SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1373
LOCK SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1374
UNLOCK SYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1375
SYNCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1377
GETINFO SYNCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1377
SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1382
CREATE SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1382
DELETE SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1383
FREQMEAS SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1383


A30808-X3247-M230-6-7619

23
CML:BSC
Id:0900d805800cef81
GET SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1384
GET SYNE STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1385
LOCK SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1386
UNLOCK SYNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1387
SYSINIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1389
SYSINIT SYSINIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1389
TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1391
GET TDPC STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1391
GETINFO TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1392
GETRELATIONSHIP TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1394
GETSUBO TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1395
GETTEST TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1396
LOCK TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1397
PERFTEST TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1398
STOPTEST TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400
SWITCH TDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1402
UNLOCK TDPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1403
TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1404
CREATE TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1404
DELETE TGTBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1408
GET TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1409
GET TGTBTS BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1411
SET TGTBTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1412
TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1418
CREATE TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1418
DELETE TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1419
GET TGTFDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1420
GET TGTFDD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1421
SET TGTFDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1422
TGTPTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1424
CREATE TGTPTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1424
DELETE TGTPTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1425
GET TGTPTPPKF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1426
GET TGTPTPPKF BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1427
SET TGTPTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1428
TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1430
CREATE TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1430
DELETE TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1431
GET TGTTDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1432
GET TGTTDD BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1433
SET TGTTDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1434
TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1436
CREATE TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1436
DELETE TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1436


24 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
GET TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1437
GET TRACE BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1438
GET TRACE STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1439
GETINFO TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1440
LOCK TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1442
SHUTDOWN TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1443
UNLOCK TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1445
UPLALLIMSITR TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1445
UPLIMSITR TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1446
TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1448
CREATE TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1448
DELETE TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1450
GET TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1451
GET TRAU BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1454
GET TRAU TIMER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1455
GET TRAU STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1455
GETINFO TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1456
GETRELATIONSHIP TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1462
GETSUBO TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1463
LOCK TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1464
SET TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1465
SHUTDOWN TRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1467
UNLOCK TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1468
TRAUOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1470
GET TRAUOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1470
GET TRAUOSUSW BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1471
GETINFO TRAUOSUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1472
SETRUNBACK TRAUOSUSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1474
TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1476
CREATE TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1476
DELETE TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1480
GET TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1482
GET TRX BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1484
GET TRX STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1485
GETINFO TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1486
GETRELATIONSHIP TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1490
GETSUBO TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1491
LOCK TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1492
SET TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1493
SHUTDOWN TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1501
UNLOCK TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1503
TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1505
GET TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1505
GET TSLA BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1506
GET TSLA STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1507


A30808-X3247-M230-6-7619

25
CML:BSC
Id:0900d805800cef81
GETRELATIONSHIP TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1508
GETSUBO TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1509
LOCK TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1509
SET TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1510
SHUTDOWN TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1512
UNLOCK TSLA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1513
X25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1515
CREATE X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1515
DELETE X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1517
GET X25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1518
GET X25A BASICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1521
GET X25A STAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1522
GETINFO X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1524
GETRELATIONSHIP X25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1526
SET X25A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1527
X25D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1530
CREATE X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1530
DELETE X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531
GET X25D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1532
GET X25D BASICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1536
GET X25D STAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1537
GETINFO X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1538
GETRELATIONSHIP X25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1541
SET X25D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542
3 BTS and TRAU Objects and Commands . . . . . . . . . . . . . . . . . . . . . . . . 1544
3.1 BTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1544
3.2 BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1544
3.3 BTSEEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1544
3.4 BTSEXS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1545
3.5 TRAUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1545
3.6 BTS and TRAU Objects and Commands . . . . . . . . . . . . . . . . . . . . . . . . 1545
3.6.1 BTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1545
3.6.2 BTSEEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1549
3.6.3 BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1553
3.6.4 BTSEXS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1559
3.6.5 TRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1561
4 Parameters/Attributes in Alphabetical Order. . . . . . . . . . . . . . . . . . . . . . 1563
a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1564
ABISCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1564
ABISFRACTTHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1564
ABISHRACTTHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1565
ABISMONTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1565
ABISTRFHITHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1566
ABISTRFLTHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1566
ABORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1566


26 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
ABUTYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1567
ACBQPFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1567
ACBQPMAX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1567
ACCEPTGDEGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1568
ACCTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1568
ACEFLFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1569
ACFERMAX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1569
ACHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1569
ACLNKTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1570
ACMAXEFLDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1570
ACMINEFLDMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1571
ACPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1572
ACTN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1575
ADVCMPHOOAMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1576
AECST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1576
AISAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1576
ALACOUNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1577
ALARMT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1577
ALARMT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1577
ALARMT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1578
ALCST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1578
ALCTGTLEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1578
ALEVFULHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1579
ALLCRIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1580
ALPHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1580
ALRMSEVBTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1580
ALRMSEVBTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1581
ALRMSEVCBCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1581
ALRMSEVCPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1582
ALRMSEVDISK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1582
ALRMSEVDK40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1582
ALRMSEVEPWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1583
ALRMSEVES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1583
ALRMSEVFAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1584
ALRMSEVFRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1584
ALRMSEVIPLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1584
ALRMSEVIXLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1585
ALRMSEVLICD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1585
ALRMSEVLICDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1586
ALRMSEVLPDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1586
ALRMSEVLPDLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1586
ALRMSEVLPDLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1587
ALRMSEVMEMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1587
ALRMSEVMPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1588
ALRMSEVNSVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1588
ALRMSEVNTW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1588
ALRMSEVOMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1589


A30808-X3247-M230-6-7619

27
CML:BSC
Id:0900d805800cef81
ALRMSEVPCMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1589
ALRMSEVPCMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1590
ALRMSEVPCMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1590
ALRMSEVPCMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1590
ALRMSEVPCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1591
ALRMSEVPPXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1591
ALRMSEVPPXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1592
ALRMSEVPTPPKF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1592
ALRMSEVPWRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1592
ALRMSEVSYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1593
ALRMSEVSYNE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1593
ALRMSEVTDPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1594
ALRMSEVTRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1594
ALRMSEVTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1594
ALRMSEVX25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1595
ALRMSEVX25D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1595
ALTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1596
AMONTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1596
AMRACMRDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1596
AMRFRC1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1597
AMRFRC2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1598
AMRFRC3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1599
AMRFRC4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1599
AMRFRIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1600
AMRFRLLCOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1601
AMRFRLLPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1602
AMRFRTH12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1603
AMRFRTH23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1604
AMRFRTH34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1604
AMRHRC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1604
AMRHRC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1605
AMRHRC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1605
AMRHRC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1606
AMRHRIC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1606
AMRHRLLCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1607
AMRHRLLPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1608
AMRHRTH12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1609
AMRHRTH23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1610
AMRHRTH34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1610
AMRLKAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1610
ANTHOPMOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1611
ANTHOPP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1611
APLESSNBSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1612
APLESSNSMLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1612
ASCILLPRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1613
ASCIONECHMDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1613
ASCISER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1614


28 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
ASCIULR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1614
ASEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1615
ASMONTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1615
ASSFAIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1616
ASSLAPD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1616
ASTRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1617
ASUBCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1617
ASUBISAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1617
ATIME<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1618
ATT<n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1618
AUTOREP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1619
b . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1620
BAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1620
BAND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1620
BANDOFHYS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1620
BARINSYSINF10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1621
BAUDRATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1621
BCCHFREQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1622
BCCHTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1622
BCGRTODIFFSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1623
BCGRWEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1623
BCKUPESU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1623
BEPAVGP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1623
BEPFIDLWEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1624
BEPFITODIFFSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1624
BER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1624
BHOFOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1625
BLERAVEDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1625
BLERAVEUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1626
BMONTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1627
BNDWIDTDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1627
BPAGCHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1628
BPRACHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1628
BSCDVMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1629
BSCOVLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1629
BSCT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1630
BSCT10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1630
BSCT11PUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631
BSCT11WPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631
BSCT13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1632
BSCT17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1632
BSCT18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1633
BSCT19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1633
BSCT20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1634
BSCT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1634
BSCT3121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1635
BSCT4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1635


A30808-X3247-M230-6-7619

29
CML:BSC
Id:0900d805800cef81
BSCT7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1636
BSCT8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1636
BSCTQHOPUB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1637
BSCTQHOWPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1637
BSIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1638
BSMONTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1638
BSPBBLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1639
BSSAPSSN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1639
BTSEFAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1640
BTSHSCSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1640
BTSOVLH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1641
BULKDCONF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1641
BURNOFFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1644
BVCBHIPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1644
BVCBLPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1645
BVCBMAPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1645
BVCBSPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1646
c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1648
C31H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1648
C32QUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1648
CACKTYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1648
CALLF<NN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1649
CBCLTYPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1649
CBCPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1650
CBQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1650
CCALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1651
CCALLF<nn> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1654
CCDIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1654
CCELL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1654
CCELL2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1655
CCHANTFACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1655
CELLBARR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1656
CELLGLID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1656
CELLRESH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1657
CELLTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1657
CFS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1657
CHPOOLTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1658
CHTYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1658
CICFM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1659
CID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1660
CITASUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1660
CLEAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1661
CLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1661
CLSETFAIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1661
CMOBALLOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1662
CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1665
CONCELL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1665


30 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
CONGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1665
CPCUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1666
CRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1666
CREALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1666
CRESELTRHINP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1667
CRESELTRHSOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1667
CRESOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1667
CRESPARI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1668
CRTSWDLLCOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1668
CRTSWDLLPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1669
CRTSWSPELLCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1670
CRTSWSPELLPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1671
CSCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1672
CSCH3CSCH4SUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1672
CUCONF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1673
d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1674
DANGEROUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1674
DBBKPPEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1674
DBVER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1674
DEFPOOLTYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1675
DELOPT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1677
DESTDIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1677
DESTPATHNAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1678
DGRSTRGY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1678
DGRSTRGYBCNT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1679
DIFFSERVSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1679
DIRNAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1680
DIRTCHASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1680
DISKCOPY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1681
DISTHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1681
DLAPDOVL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1681
DNLALLEXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1682
DNLBSSPFCRET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1682
DNLBSSPFCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1682
DPBGTHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1683
DRXTMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1683
DTEDCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1684
DTXDLFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1684
DTXDLHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1685
DTXUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1685
DUR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1686
e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1687
EAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1687
EADVCMPDCMHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1687
EADVCMPHOAMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1687
EADVCMPHOSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1688


A30808-X3247-M230-6-7619

31
CML:BSC
Id:0900d805800cef81
EANTHOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1688
EARCLM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1688
EAUTOREC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1689
EBCCHTRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1689
EBSPWCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1690
EBSPWRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1690
EBUSYCUM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1690
EC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1691
EDASUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1691
EDTMSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1692
EEDGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1692
EEICM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1692
EENHDTMSUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1693
EEOTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1693
EEXCDIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1693
EFCRESEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1694
EFRSUPP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1694
EFULHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1694
EGPLGPEIGHTTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1695
EGPLGPFIVETS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1695
EGPLGPFOURTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1695
EGPLGPONETS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1696
EGPLGPSEVENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1696
EGPLGPSIXTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1696
EGPLGPTHREETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1697
EGPLGPTWOTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1697
EGPRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1697
EGWSEIGHTTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1698
EGWSFIVETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1700
EGWSFOURTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1700
EGWSONETS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1701
EGWSSEVENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1702
EGWSSIXTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1703
EGWSTHREETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1703
EGWSTWOTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1704
EHDCTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1705
EHRACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1705
EHRACTAMR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1705
EICNF<NN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1706
EINTSITSYN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1706
EISDCCHHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1706
ELEVHOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1707
ELIMITCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1707
ELKADPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1707
ELLCOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1708
ELLPRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1709
EMANPRESCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1709


32 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
EMANPRESPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1710
EMCSFAMA1DL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1710
EMCSFAMAP1DL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1710
EMCSFAMB1DL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1711
EMCSFAMCDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1711
EMCSFAMGDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1712
EMFA1UNIR8PSK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1712
EMFAP1UNIR8PSK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1712
EMFB1UNIR8PSK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1713
EMFCUNIR8PSK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1713
EMFCUNIRGMSK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1713
EMFGUNIR8PSK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1714
EMFGUNIRGMSK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1714
EMSPWRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1715
EMT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1715
EMT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1715
ENANCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1716
ENAQUALEVHOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1716
ENCALSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1716
ENDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1717
ENFOIAHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1717
ENFORCHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1718
ENHSCSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1718
ENMDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1719
ENPERNOTDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1719
ENVANAME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1719
EPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1720
EPAT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1721
EPAT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1721
EPOOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1721
EPRE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1722
EPREHSCSD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1722
EPWCRLFW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1722
EQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1723
EQUPOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1723
ERRACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1724
ERRCORMTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1726
ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1726
ERUDGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1726
ESUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1727
ETFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1727
ETIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1728
ETXDIVTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1728
EUBCHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1729
EUHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1729
EUIMPHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1729
EUMSSNCRESEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730


A30808-X3247-M230-6-7619

33
CML:BSC
Id:0900d805800cef81
EUSCHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730
EUSCNCRESEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730
EUSDCHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1731
EVTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1731
EXCDIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1731
EXPSWV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1732
EXTCHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1733
EXTMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1733
f . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1734
FACCHQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1734
FALLBESU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1734
FCRATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1734
FCTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1735
FDDARFCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1735
FDDDIV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1736
FDDGQO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1736
FDDMURREP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1737
FDDQMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1737
FDDQMIO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1738
FDDQO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1739
FDDREPO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1739
FDDREPQTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1740
FDDREPTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1740
FDDREPTH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1741
FDDRSCPMI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1741
FDDSCRMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1742
FER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1743
FERSERTYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1744
FHAMRFRC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1744
FHAMRFRC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1745
FHAMRFRC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1746
FHAMRFRC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1746
FHAMRFRIC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1747
FHAMRFRTH12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1748
FHAMRFRTH23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1748
FHAMRFRTH34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1749
FHAMRHRC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1749
FHAMRHRC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
FHAMRHRC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
FHAMRHRC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1751
FHAMRHRIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1751
FHAMRHRTH12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1752
FHAMRHRTH23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1753
FHAMRHRTH34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1753
FHORLMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1754
FHSYID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1754
FILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1755


34 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
FILENAME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1756
FILETYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1756
FLAPDOVLTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1757
FLOWCTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1757
FPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1757
FRACTAMRTH1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1758
FRACTAMRTH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1758
FRACTTH1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1759
FRACTTH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1759
FRANOFFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1759
FRSTD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1760
FRTERM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1760
FULHOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1761
FULRXLVMOFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1761
g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1762
GAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1762
GASTRABISTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1762
GASTRTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1764
GATEWAY0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765
GATEWAY1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765
GBSNS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1766
GCELLRESH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1766
GDCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1767
GEXTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1767
GFDDMURREP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1767
GFDDQMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1768
GFDDQMIO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1768
GFDDREPQTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1769
GFDDRSCPMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1769
GHCSPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1770
GHCSTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1771
GLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1771
GLLCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1772
GLLPRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1772
GMANMSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1773
GMANPRESCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1774
GMANPRESPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1774
GMANRETS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775
GMICROCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775
GMSTXPMAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775
GNMULBAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1776
GPATH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1776
GPDPDTCHA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1777
GPENTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1777
GRANP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1778
GRESOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1779
GRXLAMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1780


A30808-X3247-M230-6-7619

35
CML:BSC
Id:0900d805800cef81
GS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1780
GSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1780
GTDDMURREP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1781
GTEMPOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1781
GTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1781
GTXINT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1782
GUARMABIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1782
GUMTSSRHPRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1783
h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1784
HANDROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1784
HANFAIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1784
HCICN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1784
HDCFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785
HDCFUPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785
HEADER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785
HIERC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1786
HIERF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1786
HOAVDIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1787
HOAVLEV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1787
HOAVPWRB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1788
HOAVQUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1788
HOCCDIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1789
HOLTHLVDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1789
HOLTHLVUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1789
HOLTHQAMRDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1790
HOLTHQAMRUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1790
HOLTHQUDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1791
HOLTHQUUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1791
HOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1791
HOMDOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1792
HOMDTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1792
HOMRGTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1792
HOMSOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1793
HOMSTAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1793
HOPMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1793
HOPP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1794
HORXLVDLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1794
HORXLVDLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795
HOSYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795
HOTDLINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1796
HOTHAMRCDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1796
HOTHAMRCUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1797
HOTHAMRDDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1797
HOTHAMRDUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1798
HOTHCMPLVDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1798
HOTHCMPLVUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1798
HOTHDCMLVDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1799


36 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
HOTHDCMLVUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1799
HOTHEFRCDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1799
HOTHEFRCUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
HOTHFRCDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
HOTHFRCUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
HOTHHRDDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1801
HOTHHRDUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1801
HOTMSRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1801
HOTMSRME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1802
HOTULINT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1802
HRACTAMRT1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1802
HRACTAMRT2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1803
HRACTT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1803
HRACTT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1803
HRDATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1804
HRDCMLIMTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1804
HRSPEECH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1804
HSCSDLLCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805
HSCSDLLPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805
HSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1806
i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1807
IDBSCESUDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1807
IDBSCESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1807
IDNEYESUSW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1808
IDRSUDB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1808
IDRSUEXE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1809
IDRSUPCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1811
IDRSUSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1811
IERCHOSDCCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1812
IMCSULNIR8PSK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1812
IMCSULNIRGMSK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1813
IMMASSFAIR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1813
IMSIATDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1814
IMSIFSIZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1814
INIBLER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1814
INICSCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815
INIMCSDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815
ININHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1816
INITLEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1817
INSTANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1817
INTAVEPR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1818
INTCLASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1818
INTCTMST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1819
INTERCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1819
INTINF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1820
INTRACH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1820
INTRTRFH1TODIFFSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1820


A30808-X3247-M230-6-7619

37
CML:BSC
Id:0900d805800cef81
INTRTRFH1WEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1821
INTRTRFH2TODIFFSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1821
INTRTRFH2WEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1821
INTRTRFH3TODIFFSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1822
INTRTRFH3WEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1822
IPADDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1822
IRACHOSDCCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1823
l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1824
L1CTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1824
L2PV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1826
L2WIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1826
L3PS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1826
L3PV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1827
L3WIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1827
LAPDOVLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1828
LAPDPOOL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1828
LAYERID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1828
LCBM<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1829
LCN2WC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1831
LCNIOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1831
LCNOOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1831
LCSMONTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1832
LCSNSSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1832
LEND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1833
LEVHOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1833
LEVONC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1833
LFID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1834
LINKTYPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1834
LISOFMONOBJS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1835
LKSET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1835
LLCDVOLTRSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1835
LOCIPEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1836
LOGTYPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1836
LOTERCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1836
LOTRACH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1837
LOWBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1837
LOWTLEVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1838
LOWTLEVU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1838
LOWTQUAD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1839
LOWTQUAMRDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1839
LOWTQUAMRUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1839
LOWTQUAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1840
LPDLMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1840
LPDLMSAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1840
LREDUNEQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1841
LSLOTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1841
LSULOTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1842


38 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
LSUPDTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1843
LWWPSPRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1844
m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1845
M2T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1845
M2T2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1845
M2T3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1845
M2T4E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1846
M2T4N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1846
M2T5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1846
M2T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1846
M2T7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1847
M3T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1847
M3T10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1847
M3T12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1848
M3T13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1848
M3T14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1848
M3T17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1849
M3T19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1849
M3T1TM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1849
M3T2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1850
M3T22OR20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1850
M3T23OR21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1850
M3T2TM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1851
M3T3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1851
M3T4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1851
M3T5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1852
MACONN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1852
MADGRLV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1852
MAFAILNCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1853
MAFIRACHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1853
MAIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1853
MAIRACHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1854
MASCLOGFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1854
MAXFAILHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1854
MAXLAPDMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1855
MAXNCELL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1855
MAXRETR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1855
MEAEXTBCCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1856
MEASET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1856
MEASLST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1856
MEASOBJLST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1862
MECNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1870
MEDAFUPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1870
MEDAFUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1870
MELID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1871
MICROCELL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1871
MINCCNT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1872


A30808-X3247-M230-6-7619

39
CML:BSC
Id:0900d805800cef81
MISTSTRSH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1872
MNTBMASK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1872
MOBALLOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1876
MODBSSPFCRET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1880
MODBSSPFCT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1880
MOEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1880
MONOBJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1881
MORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1881
MPCCCOPY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1882
MSBHIPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1882
MSBLPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1882
MSBMAPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1883
MSBSPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1884
MSCOVLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1885
MSCPERTFLAG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1885
MSCPOOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1886
MSCSPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1886
MSCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1887
MSRMAXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1887
MSTXPMAXCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1887
MSTXPMAXDCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1888
MSTXPMAXGSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1888
MSTXPMAXPCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1889
MSTXPMAXUMTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1889
MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1889
n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1891
N1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1891
N2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1891
N2WC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1891
N3101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1892
N3103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1892
N3105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1892
N391 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1893
N392 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1893
N393 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1893
NACCNTWCOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1894
NALLWACC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1894
NAVGI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1895
NBLKACGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1896
NBVCBR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1896
NBVCRR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1896
NBVCUR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1897
NCC1TH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1897
NCC1THADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900
NCDP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1902
NCDP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1904
NCELL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1905


40 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
NCGPENTIME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1905
NCGRESOFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1913
NCGTEMPOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1917
NCRARESH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1920
NCRESELFLAG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1922
NCSARA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1922
NCTRFPSCTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1922
NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1923
NECI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1923
NETWTYPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1923
NEWESU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1924
NFRAMEPG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1924
NIOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1925
NMDLATT<NN>. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1925
NMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1926
NMULBAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1926
NNSVCBLKR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1926
NNSVCRR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1927
NNSVCTSTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1927
NNSVCUBLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1927
NOBAKHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1928
NOCHBLKN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1928
NOCHFBLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1928
NOFREPHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1929
NOIREDA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1929
NOIREDST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1929
NOOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1930
NOTFACCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1930
NRACPBLUPDRET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1931
NRLCMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1931
NRPGRANT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1932
NSCONN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1932
NSEI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1933
NSLOTST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1934
NSVCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1934
NSVLI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1934
NTWCARD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1935
NTWCNDRXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1935
NTWCONCRESFAIR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1935
NTWCOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1936
NTWCREPPIDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1936
NTWCREPPTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1937
NTWEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1937
NTWIND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1950
NUA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1951
NY1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1951


A30808-X3247-M230-6-7619

41
CML:BSC
Id:0900d805800cef81
o . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1952
OBJLST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1952
OMCCPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1954
OMLAPDRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1954
OPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1955
OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1955
OVERWRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1955
OVLENTHR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1956
OVLSTTHR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1956
OWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1957
p . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1958
PAGCOORCLB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1958
PAGQOVLIND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1958
PATHNAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1958
PAVRLEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1959
PAVRQUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1959
PBGTHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1960
PCCCHLDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1960
PCMBSTXPRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1961
PCMCON<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1961
PCMECH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1965
PCML . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1966
PCMSN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1966
PCMSOBJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1967
PCMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1967
PCMTYPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1967
PCONINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1968
PCRLFTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1968
PCUID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1968
PCUPRCSLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1969
PENTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1969
PERM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1969
PERSTLVPRI<N>. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1970
PERWEEK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1970
PFCBBHIPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1972
PFCBBLPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1972
PFCBBMAPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1973
PFCBBMAPPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1974
PFCBRMAXU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1975
PFCBRPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1975
PFCFCSUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1976
PFCIBHIPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1977
PFCIBLPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1977
PFCIBMAPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1978
PFCIBMAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1979
PFCIRMAXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1980
PFCIRPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1980


42 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
PFCSBHIPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1981
PFCSBLPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1982
PFCSBMAPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1982
PFCSBMAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1983
PFCSRMAXU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1984
PFCSRPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1984
PFCSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1985
PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1986
PHYADDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1986
PKTMEASREPCNT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1987
PKTNDEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1987
PKTNINC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1988
PKTNMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1988
PL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1988
PLMNP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1989
PLNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1989
PNOFACCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1990
POOLTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1990
PORT<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1992
PPLNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1992
PREAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1993
PRIMARYIPADDR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1993
PRIORITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1993
PRIOSLOTN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1994
PROCTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1994
PROCTYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1995
PRPBCCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1995
PVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1995
PWRCONF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1996
PWREDSS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1996
PWRINCSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1996
PWROFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1997
PWROUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1997
PWRRED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1998
q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1999
QLPUB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1999
QLWPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1999
QSRHC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1999
QSRHCINI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
QSRHI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001
QSRHPRI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001
QUALLEVHOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2002
r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2004
R20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2004
R22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2004
R23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2004


A30808-X3247-M230-6-7619

43
CML:BSC
Id:0900d805800cef81
RAARET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2005
RACHBT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2005
RACHLAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2005
RACODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006
RACOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006
RADIOMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006
RADIOMR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2006
RAENV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2007
RARESH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2007
RAVEW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2008
RDGRDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2008
RDGRUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2009
RDLNKTBS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2009
RDLNKTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2010
RECCRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2010
RECINT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2010
RELCMD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2012
RELF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2012
RELOBJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2013
RELRSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2013
REMAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014
REPTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014
REQATTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014
RETRY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2016
RFRSINDP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2016
RHOLTQDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2016
RHOLTQUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2017
RMTIPEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2017
RNCID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2017
ROUIPADD<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2018
RUGRDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2018
RUGRUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2019
RUNESU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2019
RXLEVAMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2019
RXLEVHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2020
RXLEVMIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2020
RXLEVMINC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2020
RXLV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2021
RXLVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2021
RXQUALHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2022
s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2023
SALUNAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2023
SANTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2023
SANUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2023
SCHWEIPRI1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2024
SCHWEIPRI2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2024
SCHWEIPRI3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2024


44 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
SCHWEIPRI4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2025
SDCCHCONGTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2025
SDCCHDROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2025
SDCCHLOSR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2026
SECONDARYIPADDR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2026
SG10HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2026
SG10PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2027
SG11HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2029
SG11PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2029
SG12HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2031
SG12PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2031
SG13HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2033
SG13PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2033
SG14HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2035
SG14PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2035
SG1HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2037
SG1PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2037
SG2HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2039
SG2PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2039
SG3HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2041
SG3PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2041
SG4HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2043
SG4PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2043
SG5HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2045
SG5PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2045
SG6HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2047
SG6PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2047
SG7HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2049
SG7PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2049
SG8HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2051
SG8PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2051
SG9HOPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2053
SG9PCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2053
SHLAPDIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2055
SIMSCREL99. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2055
SISGSNREL99 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2055
SLAPDOVLTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2056
SLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2056
SLLPRM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2057
SMLCPERTFLAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2057
SMLCSPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2058
SMSCBUSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2058
SMSINFO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2059
SMSPFITODIFFSERV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2059
SNSADDRET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2059
SNSCHWEIRET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2060
SNSCONFRET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2060


A30808-X3247-M230-6-7619

45
CML:BSC
Id:0900d805800cef81
SNSDELRET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2060
SNSSIZERET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2061
SOURCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2061
SPEED145 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2061
SPENLAW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2062
SPFITODIFFSERV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2062
SPFIWEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2062
SRCDIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2063
SRCFILE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2063
SRCPATH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2064
SRCPATHNAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2064
SS7MTPTYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2064
START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2065
STGTTLLIINF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2066
STOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2066
STPIPEP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2067
STREAMSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2068
STREAMTODIFFSERV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2068
STREAMWEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2068
SUBBAND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2069
SUBNETMASK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2069
SUBNETMASK<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2069
SUPPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2070
SYNCHRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2070
SYSID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2071
SYSPACKSYSSUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2071
t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2073
T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2073
T10UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2073
T12UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2074
T13UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2074
T14UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2074
T17UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2075
T19UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2075
T1TMUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2075
T1UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2076
T1UNIT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2076
T2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2077
T20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2077
T200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2077
T21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2078
T22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2078
T22OR20UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2079
T23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2079
T23OR21UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2079
T26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2080
T28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2080


46 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
T2TMUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2080
T2UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2081
T2UNIT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2081
T3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2081
T3101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2082
T3105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2082
T3107. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2083
T3109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2084
T3111. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2084
T3122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2085
T3141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2085
T3168. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2085
T3169. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2086
T3172. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2086
T3191. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2086
T3192. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2087
T3193. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2087
T3195. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2087
T3197. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2088
T3212. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2088
T391. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2088
T3UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2089
T3UNIT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2089
T4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2089
T4EUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2090
T4NUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2090
T4UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2091
T5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2091
T5UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2091
T5UNIT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2092
T6UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2092
T7UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2092
TAADJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2093
TARGDIR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2093
TARGF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2094
TAVGT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2094
TAVGW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2094
TBFDROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2094
TBFLOSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2095
TBFREAFAIR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2095
TBNCU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2096
TCBCSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2096
TCCCHLDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2096
TCHDROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2097
TCHLOSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2097
TCONG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2097
TCONN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2098


A30808-X3247-M230-6-7619

47
CML:BSC
Id:0900d805800cef81
TCONNUNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2098
TCONOFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2098
TDDARFCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2099
TDDCPAR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2099
TDDDIV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2100
TDDGQO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2100
TDDMURREP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2101
TDDQO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2101
TDDREPO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2102
TDDREPTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2103
TDDSYNCCAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2103
TDPCPRCSLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2104
TDTMWIND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2104
TEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2105
TEMPCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2105
TEMPOFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2105
TEMPPDT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2106
TEXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2106
TEXTULTBF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2106
TF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2107
TF1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2107
TFAILNCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2107
TGRANT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2108
TGTCELL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2108
TGUARD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2108
TGUARDTCHSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2109
TGUARDUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2109
TH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2110
THLEVFULHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2110
THORQST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2110
THPROXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2111
THR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2111
THRS<N> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2112
THSULBAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2113
TIAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2113
TIARUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2113
TIAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2114
TIASUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2114
TIMADVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2115
TIMEDTBFREL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2116
TIMERFHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2116
TINHBAKHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2117
TINHFAIHO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2117
TINHRDGR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2117
TINHRUGR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2118
TINOIERCHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2118
TINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2118


48 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
TINTUNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2119
TNOCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2119
TNSVCBLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2119
TNSVCPTST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2120
TNSVCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2120
TNSVCTST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2121
TO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2121
TOPOREL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2122
TOTERM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2122
TPFCBUFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2122
TRACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2123
TRACECH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2123
TRACEMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2123
TRACEMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124
TRACERECTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124
TRACEREF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124
TRANSPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2125
TREL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2125
TRELUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2126
TRESEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2126
TRFCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2127
TRFHITH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2127
TRFHOE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2127
TRFHOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2128
TRFHORXLVMOFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2128
TRFHOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2128
TRFKPRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2129
TRFLTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2129
TRFMMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2130
TRFMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2130
TRFPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2130
TRFPSCTRLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2131
TRXAREA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2131
TRXFREQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2131
TRXFREQV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2136
TRXMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2137
TSBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2137
TSBSUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2137
TSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2138
TSLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2138
TSNPRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2138
TSULBAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2139
TSYNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2139
TSYNCDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2140
TSYNCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2140
TSYNCUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2140
TTRAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2141


A30808-X3247-M230-6-7619

49
CML:BSC
Id:0900d805800cef81
TUESP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2141
TUPLREP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2141
TWCUNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2142
TWCUSER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2142
TXDIVTSEXCPT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2142
TXDIVTSPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2143
TYPOFAMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2145
TYPOFETH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2145
TYPOFNSVCCONF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2146
TYPPROC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2146
u . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2147
UADJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2147
ULAB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2147
ULABSWLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2148
UMECNO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2148
UMTSSRHPRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2149
UPGRFREQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2149
UPTLEVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2150
UPTLEVU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2151
UPTQUAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2151
UPTQUAMRDL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2151
UPTQUAMRUL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2152
UPTQUAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2152
USECNO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2153
USECNONCRESEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2153
USFGRAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2154
USG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2154
USRSCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2155
USRSCPNCRESEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2155
v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2157
VER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2157
VGRULF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2157
VOLDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2158
VOLUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2158
VQEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2159
w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2160
WEID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2160
WEIS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2160
WMOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2160
WPSPREF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2161
WRTYP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2161
x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2162
X121ADDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2162


50 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
5 Appendix A: ME-Address Value List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2163
6 Appendix B: Special Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . 2166
6.1 Special Parameter Values - Group 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2168
6.2 Special Parameter Values - Group 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2186
6.3 Special Parameter Values - Group 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2188
6.4 Special Parameter Values - Group 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2190
6.5 Special Parameter Values - Group 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2193
6.6 Special Parameter Values - Group 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2198
6.7 Special Parameter Values - Group 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2200
6.8 Special Parameter Values - Group 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2206


A30808-X3247-M230-6-7619

51
CML:BSC
Id:0900d805800cef81
List of Figures
Figure 1 BSC BR8.0: Tree View in Online Mode . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 2 BSC BR8.0: Graphic View in Online Mode . . . . . . . . . . . . . . . . . . . . . . 58
Figure 3 BSC BR8.0 Tree View with List of Command . . . . . . . . . . . . . . . . . . . . 59
Figure 4 BSC BR8.0: CREATE... CPCU Command (example) . . . . . . . . . . . . . . 60
Figure 5 BSC BR8.0: SET... BSC Command (example) . . . . . . . . . . . . . . . . . . . 60
Figure 6 Command Viewer Window: CREATE... CPCU Command (example) . . 60
Figure 7 Command Viewer Window: SET... BSC Command (example) . . . . . . . 61
Figure 8 BSC containment tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 9 BSS Functional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 10 Open Interworking function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 11 Interworking panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 12 Close interworking function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 13 BTSE containment sub-tree (example in Training Script mode) . . . . . . 65
Figure 14 BTSEP containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 15 BTSEEM containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 16 BTSEXS containment sub-tree (example in Training Script mode) . . . . 68
Figure 17 TRAUE containment sub-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69


52 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cef81
List of Tables
Table 1 Frequency values for P-GSM 900. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2169
Table 2 Frequency values for E-GSM 900 (from 0 to 124) . . . . . . . . . . . . . . . 2171
Table 3 Frequency values for E-GSM 900 (from 975 to 1023) . . . . . . . . . . . . 2173
Table 4 Frequency values for DCS 1800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2173
Table 5 Frequency values for GSM-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2179
Table 6 Frequency values for PCS 1900. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2180
Table 7 Frequency values for GSM 850 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2184
Table 8 Values for received signal threshold. . . . . . . . . . . . . . . . . . . . . . . . . . 2187
Table 9 Relationship between Signal Quality and BER. . . . . . . . . . . . . . . . . . 2189
Table 10 Values for GSM and R-GSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2190
Table 11 Values for DCS 1800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2190
Table 12 Values for PCS 1900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2191
Table 13 Values for UMTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2192
Table 14 Circuit Pool Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2193
Table 15 Conversion of RXQUAL to C/I for settings related to AMR HO and PWRC
parameters.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2198
Table 16 Correspondence between service dependent and service independent at-
tributes (SGXHOPAR, X =1..2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2201
Table 17 Correspondence between service dependent and service independent at-
tributes (SGXHOPAR, X =3, 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2201
Table 18 Correspondence between service dependent and service independent at-
tributes (SGXHOPAR, X =5, 6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2202
Table 19 Correspondence between service dependent and service independent at-
tributes (SGXHOPAR, X = 7, 8, 9, 10) . . . . . . . . . . . . . . . . . . . . . . . . 2203
Table 20 Correspondence between service dependent and service independent at-
tributes (SGXHOPAR, X = 11, 12) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2203
Table 21 Correspondence between service dependent and service independent at-
tributes (SGXHOPAR, X = 13, 14) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2204
Table 22 Correspondence between service dependent and service independent at-
tributes (SGXPCPAR, X = 1..10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2204
Table 23 Correspondence between service dependent and service independent at-
tributes (SGXPCPAR, X = 11..14) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2205


A30808-X3247-M230-6-7619

53
CML:BSC Reason for Update
Id:0900d805800ca295
Reason for Update
Summary
Sixth Edition for Release BR 8.0
Details:
Issue History
Chapter/Section Reason for Update
All Minor changes on parameters and descriptions
Issue Date Summary
01 01/2005 First Edition for New Release BR 8.0
02 04/2005 Second Edition for Release BR 8.0
03 07/2005 Third Edition for Release BR 8.0
04 11/2005 Fourth Edition for Release BR 8.0
05 03/2006 Fifth Edition for Release BR 8.0
06 10/2006 Sixth Edition for Release BR 8.0


54 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ca295
Reason for Update


A30808-X3247-M230-6-7619

55
CML:BSC Introduction
Id:0900d805800c63b3
1 Introduction
In the CML:BSC document the commands are described in Alphabetical order of the
Managed Object. Described commands can be executed by the operator after connect-
ing the Local Maintenance Terminal (LMT Evoluition) to the BSC network element.
1.1 Structure of the Manual
There is the possibility to jump by clicking on the selected item (reference to the param-
eter description or to the GUI representation in chapter 2; reference to the commands in
chapter 3) to the requested information.
The manual is subdivided into four main parts:
a) Chapter 1 provides general informations about command structure and LMT Evolu-
tion operations.
b) Chapter 2 describes objects and commands, listed in alphabetical order.
c) Chapter 3 describes the parameters of the commands, listed in alphabetical order.
Additionally there is the information in which commands the parameter is used.
d) Appendix A describes the ME-Address Value List and Appendix B describes the
Special Parameters Values.
In the command representation (chapter 2) the parameters/attributes in brackets are
optional parameters.
1.2 Structure of the Commands
Both generic commands which can be obtained through selections from the LMT Evo-
lution tree and commands which are created by the operator using the CLI interface
must use the following syntax:
1. action object [3rd identifier]:NAME=object:n[/object:n],attribute=value[-value]
[,attribute=value];
2. action object :NAME=object:n[/object:n],attribute=value[&value] [,attribute=value];
3. action object [3rd identifier]:NAME=object:n[/object:n],REQATTL=attribute
[&attribute];
4. action object [3rd identifier]:NAME=object:n[/object:n];
g The syntax rules shown in example 2. are used only for GET commands.
where:
"action specifies the command that is being executed and that belongs to a list of func-
tions applicable to the BSC system (for example: "CREATE", "DELETE", "SET", etc).
object represents the hardware or logical identifier that must be submitted to the
command (for example: "ADJC", "BTS", "BTSM", etc).
[object] logical identifier that must be submitted to the commands (for example:
"NOSWL", "SWL").
!
CAUTION - Compatible Software Version:
In order to use the LMT correctly, the LMT Evolution software version and the others
network elements software version, such as BSC, should be aligned as described in the
Release Note.


56 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
"n" specifies the relative number (for example: BTS:n n=0,). The LMT Evolution CLI
allows * or & instead of a simple number for a object instance (for example: BTS:*
(all), BTS:0&2&3 (0,2,3) or BTS:0&&3 (0,1,2,3).
"attribute" is the acronym of the real attribute of an object (for example: BSIC=Base
Station Identity Code).
"value" represent the value of the attribute (or the values of its fields). It is possible to
input a value not just using the default data type (usually decimal) but also to input the
data e.g. as hex value or as binary value.
1.3 Command Layout
The first information given for each command is the phase, or phases, within which the
command can be entered. Then, subsequent selections are shown which are required
to get the command starting from the LMT Evolution Tree.
The command is specified with its syntax and it is followed by the individual fields used
to explain the functions of the command itself.
Command Tree:
The command tree shows the way to get the command and a hint to a GUI example in
chapter 1.
Applicability:
This field shows the working phases and the user profile which allow the execution of
the command. The user profile visibility level is associated with a user identification
"user_id" and password. Four user profiles visibility level are provided:
Each profile gives the user different access levels to the system features and the higher
is the level the higher is the number of operations which can be performed.
g For User_id and Password contact your local service organization.
Command Description:
This field explains the function of the command transmitted by the LMT Evolution to the
BSC (when and why it is used, for which operation task).
Long Names:
This part shows (for a overview) the abbreviations of the parameters/attributes used in
the command and its corresponding long names.
System Responses:
They are response messages sent as acknowledgment for completion of input
commands or they contain information requested by the user. The typical structure of
the response messages contains: the date and time, the command line, the system
response. The response messages can be either normal (successful) or error mes-
sages. In such a case they contain the reason for the failure.
0 ReadOnly
1 Command Access
2 ReadWrite
3 Super User


A30808-X3247-M230-6-7619

57
CML:BSC Introduction
Id:0900d805800c63b3
Short system messages such as: indication of system loading/downloading functions in
progress, are also reported as information to the LMT Evolution.
Application Guidelines:
These are warnings given when using this command or information related to the envi-
ronment in which the command is submitted.
Example of Command Execution:
This is an example on how to enter the command with its parameters and their relevant
values.
1.4 Graphical User Interface (GUI) Representation of the LMT
Evolution
1.4.1 Start LMT Evolution Window
LMT Evolution is the graphical user interface which performs the command interaction
with the Network Element. This enables the user to navigate the object containment
Tree View (see Figure 1) or Graphic View (see Figure 2) of the NE and to select a
specific command from a list of available ones.
From the graphical point of view, the LMT Evolution Main window provides an access
point to all the LMT functionalities and represents an overall monitoring mode as regards
the connection status information.
According to its dynamic and "adaptive" properties, the LMT Evolution Main window is
displayed taking into account the connection and operating parameters that may affect
the visualization of the resulting window functionalities.
The main parameters that influence the visualization of LMT Main Window are:
Working Context: indicates a mode in which the user is currently working with the
LMT Evolution.
Network Element configuration: family, type, phase, version, ect.
By using the LMT Evolution the user can:
acquire commands, action or scripts
send and receive messages containing commands or responses to/from the
network element
have script/commands translation services
store issued commands and retrieve responses coming from the NE.
!
CAUTION - Possible misalignments
The reported figures are only for reference and could be not aligned to the last version
of LMT Evolution product.


58 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
Figure 1 BSC BR8.0: Tree View in Online Mode
Figure 2 BSC BR8.0: Graphic View in Online Mode


A30808-X3247-M230-6-7619

59
CML:BSC Introduction
Id:0900d805800c63b3
1.4.2 LMT Evolution Windows for GET, CREATE, SET,...., Commands
The LMT Evolution is mainly used to build CREATE, SET, GET, LOCK, UNLOCK etc.
commands to be sent to the Network Element. Starting from the containment Tree View
or Graphic View, the user has to perform the following operations:
select the functional/equipment/software management object
select a command from the list of commands diplsyed by the pop up list box (see
Figure 3).
Figure 3 BSC BR8.0 Tree View with List of Command
The presence of ellipses (see FORMAT... DISK Command) following the name of the
command indicates that the command could require a further configuration of the
attributes before beeing submitted. In this case the Command Viewer window is opened
and the user can fill in the attribute cells as desired .
If no ellipses are present (see LOCK DISK Command), the command does not need any
further configuration and it is submitted to the network element without opening the
Command Viewer window.
In case of the presence of ellipses (see CREATE... CPCU Command in Figure 4 or
SET... BSC Command in Figure 5) the Command Viewer panel is displayed (see Figure
6 and Figure 7). The user has to perform the following operations:
select one or more parameters and chooses the appropriate values, the command
is executed after clicking on the Submit button.
If, during the translation phase, an error is found in the command string, the
command is not sent to the N.E. In this case reenter the command following the
instructions provided by the diagnostic message shown in the right middle pane.


60 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
Figure 4 BSC BR8.0: CREATE... CPCU Command (example)
Figure 5 BSC BR8.0: SET... BSC Command (example)
Figure 6 Command Viewer Window: CREATE... CPCU Command (example)


A30808-X3247-M230-6-7619

61
CML:BSC Introduction
Id:0900d805800c63b3
Figure 7 Command Viewer Window: SET... BSC Command (example)
For all procedures of module replacement the actions to be performed are similar. As
first action, the module must be locked, replaced, tested and finally unlocked. Some
modules have to be replaced without locking and for some others, has to be switched
from phase 3 to 2.


62 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
1.5 LMT BSC Commands
1.5.1 BSC Containment Tree
In the next Figure 8, the BSC containment tree is drawn as it is shown to the user in the
LMT layout.
Figure 8 BSC containment tree
MEL
MANAGED-ELEMENT
BSS-EQUPMENT
BSS-FUNCTONAL
SOFTWARE-MANAGEMENT
BSCE
REMNV
BSCETEST
DK40
EPWR
XLT
LCD
LCDS
MEMT
MPCC
NTW
PWRD
ENVA
PPXU
PPXL
TDPC
CPEX
FAN
DSK
ES
SEE NEXT FGURE
BSCESUDB
BSCESUSW
BSCOSUDB
BSCOSUSW
FLEHANDLER
NEYESUSW
RSUDB
RSUSWLH
SYSNT
RSUEXE
RSUPCH


A30808-X3247-M230-6-7619

63
CML:BSC Introduction
Id:0900d805800c63b3
Figure 9 BSS Functional
MANAGED-ELEMENT
BSS-FUNCTONAL
BSC
BTSM
FRL
GBPLNK
QSMONBSC
QSTHRS
QSMONBTSCO
QSMONGPRSCO
PCMA
PCMB
PCMG
PCMS
TRACE
CTRCO
OPC
SS7S
SS7L
OMAL
NSVC
NUC
PCU
CBCL
X25A
X25D
CPCU
TGTBTS
TGTTDD
HDCTR
PL
TRANSFCTRL
SCANBTSOHOS
SCANFBTSM
TGTFDD
TRAU
SCANBSC
SCANBTS
SCANBTSHO
SCANBTSM
SCANBTSOHO
SCANBTSOHON
SCANCHAN
SCANCO
SCANCTRX
SCANGPRS
SCANBTSE
SCANSS7L
SCANTRX
SYNE
SYNCO
SYNC
BTSMOSUSW
BTS
CBTS
LPDLM
CFHSY
ADJC
FHSY
HAND
PWRC
PTPPKF
TRX
SCA
RFLOOP
ADJC3G
QSMONBTS
QSMONGPRS
CHAN
LPDLR
TGTPTPPKF
TSLA
TSLB SUBTSLB
CTRSCHED
NSVCP
NSVLP
RNSVLP
LPDLS
TRAUOSUSW


64 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
1.5.2 BTS Equipment and TRAU Containment Sub-Trees
Using the Open Interworking function the operator can have access to the BTS equip-
ment and TRAU containment sub-trees to perform interworking commands (see Figure
10 and Figure 11).
Figure 10 Open Interworking function
Figure 11 Interworking panel
To return to the BSC containment tree the operator has to be choose the item of menu
Close Interworking (see Figure 12).
For the list of the commands related to each BTSE object refer to paragraph BTSE in
Chapter 3 (BTS and TRAU Objects and Commands) of this manual.


A30808-X3247-M230-6-7619

65
CML:BSC Introduction
Id:0900d805800c63b3
Figure 12 Close interworking function
The following containment sub-trees are provided:
BTSE
It is related to the following BTSE types: BS-20, BS-21E, BS-22, BS-60 and BS-61E.
Figure 13 BTSE containment sub-tree (example in Training Script mode)
BTSEP
It is related to the following BTSE types: BS-240, BS-240SR, BS-241, BS-241SR,
BS-240XL, BS-240XLSR, BS-40 and BS-41, BS40 II, BS82 II.


66 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
Figure 14 BTSEP containment sub-tree
BTSEEM
It is related to the BS-82 BTSE type.


A30808-X3247-M230-6-7619

67
CML:BSC Introduction
Id:0900d805800c63b3
Figure 15 BTSEEM containment sub-tree
BTSEXS
It is related to the BS-240XS BTSE type.


68 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
Figure 16 BTSEXS containment sub-tree (example in Training Script mode)
TRAUE
It is related to TRAU equipment.


A30808-X3247-M230-6-7619

69
CML:BSC Introduction
Id:0900d805800c63b3
Figure 17 TRAUE containment sub-tree


70 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
1.5.3 Alphabetical List of Commands
Managed Element Phase1 Phase2
ADJC
CREATE ADJC
DELETE ADJC
GET ADJC
GET ADJC BASICS
SET ADJC
Managed Element Phase1 Phase2
ADJC3G
CREATE ADJC3G
DELETE ADJC3G
GET ADJC3G
GET ADJC3G BASICS
SET ADJC3G
Managed Element Phase1 Phase2
BSC
BRIDGE BSC
GET BSC
GET BSC ALARMSEV
GET BSC BASICS
GET BSC CONTROL
GET BSC FLAGS
GET BSC TIMER
GET BSC STAT
GETLOCKED BSC
MEMDUMP BSC
SET BSC
Managed Element Phase1 Phase2


A30808-X3247-M230-6-7619

71
CML:BSC Introduction
Id:0900d805800c63b3
BSCE
GET BSCE
GET BSCE ALARMSEV
GET BSCE BASICS
GET BSCE REMINV
GETACTIVEALARMS
BSCE
PERFTEST BSCE
SET BSCE
STOPTEST BSCE
Managed Element Phase1 Phase2
BSCESUDB
GET BSCESUDB
GET BSCESUDB BASICS
GET BSCESUDB STAT
GETINFO BSCESUDB
Managed Element Phase1 Phase2
BSCESUSW
GET BSCESUSW
GET BSCESUSW BASICS
GET BSCESUSW STAT
GETINFO BSCESUSW
Managed Element Phase1 Phase2
BSCETEST
GET BSCETEST
Managed Element Phase1 Phase2
BSCOSUDB
GET BSCOSUDB
GET BSCOSUDB BASICS


72 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GETINFO BSCOSUDB
SAVEDB BSCOSUDB
SET BSCOSUDB
SETRUNNEW BSCOSUDB
Managed Element Phase1 Phase2
BSCOSUSW
GET BSCOSUSW
GET BSCOSUSW BASICS
GETINFO BSCOSUSW
SET BSCOSUSW
SETBACKNEW
BSCOSUSW
SETRUNBACK
BSCOSUSW
SETRUNNEW
BSCOSUSW
Managed Element Phase1 Phase2
BTS
CREATE BTS
DELETE BTS
GET BTS
GET BTS ADM
GET BTS AMRPARAME-
TERS
GET BTS BASICS
GET BTS CCCH
GET BTS CELLFREQDEFI-
NITION
GET BTS INTERF
GET BTS OPTIONS
GET BTS SERVICE
GET BTS TIMER
GET BTS STAT
GETINFO BTS


A30808-X3247-M230-6-7619

73
CML:BSC Introduction
Id:0900d805800c63b3
GETRELATIONSHIP BTS
GETSUBO BTS
LOCK BTS
MONITOR BTS
SET BTS
SHUTDOWN BTS
UNLOCK BTS
Managed Element Phase1 Phase2
BTSM
CREATE BTSM
DELETE BTSM
GET BTSM
GET BTSM BASICS
GET BTSM STAT
GETINFO BTSM
GETRELATIONSHIP BTSM
GETSUBO BTSM
LOCK BTSM
SET BTSM
SHUTDOWN BTSM
UNLOCK BTSM
Managed Element Phase1 Phase2
BTSMOSUSW
GET BTSMOSUSW
GET BTSMOSUSW
BASICS
GETINFO BTSMOSUSW
SETRUNBACK BTSMO-
SUSW
Managed Element Phase1 Phase2
CBCL


74 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
CREATE CBCL
DELETE CBCL
GET CBCL
GET CBCL BASICS
GET CBCL X25INFO
GET CBCL STAT
GETRELATIONSHIP CBCL
LOCK CBCL
UNLOCK CBCL
Managed Element Phase1 Phase2
CBTS
CREATE CBTS
DELETE CBTS
GET CBTS
GET CBTS BASICS
GETINFO CBTS
SET CBTS
Managed Element Phase1 Phase2
CFHSY
CREATE CFHSY
DELETE CFHSY
GET CFHSY
GET CFHSY BASICS
SET CFHSY
Managed Element Phase1 Phase2
CHAN
CREATE CHAN
DELETE CHAN
GET CHAN
GET CHAN BASICS


A30808-X3247-M230-6-7619

75
CML:BSC Introduction
Id:0900d805800c63b3
GET CHAN STAT
GETRELATIONSHIP
CHAN
GETSUBO CHAN
LOCK CHAN
SET CHAN
SHUTDOWN CHAN
UNLOCK CHAN
Managed Element Phase1 Phase2
CPCU
CREATE CPCU
DELETE CPCU
GET CPCU
GET CPCU BASICS
SET CPCU
Managed Element Phase1 Phase2
CPEX
GET CPEX STAT
GETRELATIONSHIP CPEX
GETSUBO CPEX
GETTEST CPEX
LOCK CPEX
PERFTEST CPEX
STOPTEST CPEX
UNLOCK CPEX
Managed Element Phase1 Phase2
CTRCO
GET CTRCO STAT
GETINFO CTRCO
LOCK CTRCO
UNLOCK CTRCO


76 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
UPLALLCELLTR CTRCO
UPLCELLTR CTRCO
Managed Element Phase1 Phase2
CTRSCHED
CREATE CTRSCHED
DELETE CTRSCHED
GET CTRSCHED
GET CTRSCHED BASICS
GET CTRSCHED STAT
LOCK CTRSCHED
SET CTRSCHED
UNLOCK CTRSCHED
Managed Element Phase1 Phase2
DISK
FORMAT DISK
GET DISK STAT
GETRELATIONSHIP DISK
GETSUBO DISK
GETTEST DISK
LOCK DISK
PERFTEST DISK
STOPTEST DISK
UNLOCK DISK
Managed Element Phase1 Phase2
DK40
GET DK40 STAT
GETRELATIONSHIP DK40
GETSUBO DK40
GETTEST DK40
LOCK DK40


A30808-X3247-M230-6-7619

77
CML:BSC Introduction
Id:0900d805800c63b3
PERFTEST DK40
STOPTEST DK40
UNLOCK DK40
Managed Element Phase1 Phase2
ENVA
CREATE ENVA
DELETE ENVA
GET ENVA
GET ENVA BASICS
GET ENVA STAT
LOCK ENVA
SET ENVA
UNLOCK ENVA
Managed Element Phase1 Phase2
EPWR
CREATE EPWR
DELETE EPWR
GET EPWR
GET EPWR STAT
GETSUBO EPWR
GETTEST EPWR
LOCK EPWR
PERFTEST EPWR
STOPTEST EPWR
UNLOCK EPWR
Managed Element Phase1 Phase2
ES
GET ES STAT
GETINFO ES
GETRELATIONSHIP ES


78 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GETSUBO ES
GETTEST ES
LOCK ES
PERFTEST ES
STOPTEST ES
UNLOCK ES
Managed Element Phase1 Phase2
FAN
GET FAN STAT
GETRELATIONSHIP FAN
GETSUBO FAN
Managed Element Phase1 Phase2
FHSY
CREATE FHSY
DELETE FHSY
GET FHSY
GET FHSY BASICS
SET FHSY
Managed Element Phase1 Phase2
FILEHANDLER
COPY FILEHANDLER
CREATEDIR FILEHAN-
DLER
DELETE FILEHANDLER
GENFILE
DIR FILEHANDLER
FILECOM FILEHANDLER
FILEDECOM FILEHAN-
DLER
MOVE FILEHANDLER


A30808-X3247-M230-6-7619

79
CML:BSC Introduction
Id:0900d805800c63b3
REMOVEDIR FILEHAN-
DLER
UPLPRLOG FILEHAN-
DLER
Managed Element Phase1 Phase2
FRL
CREATE FRL
DELETE FRL
GET FRL
GET FRL BASICS
GET FRL STAT
GETINFO FRL
GETRELATIONSHIP FRL
GETSUBO FRL
LOCK FRL
SET FRL
UNLOCK FRL
Managed Element Phase1 Phase2
GBIPLNK
CREATE GBIPLNK
DELETE GBIPLNK
GET GBIPLNK
GET GBIPLNK STAT
GETRELATIONSHIP
GBIPLNK
GETSUBO GBIPLNK
LOCK GBIPLNK
UNLOCK GBIPLNK
Managed Element Phase1 Phase2
HAND
GET HAND


80 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GET HAND BASICS
GET HAND DATA
SET HAND
Managed Element Phase1 Phase2
HDCTR
CREATE HDCTR
DELETE HDCTR
GET HDCTR
GET HDCTR BASICS
GET HDCTR STAT
GETINFO HDCTR
LOCK HDCTR
SET HDCTR
UNLOCK HDCTR
UPLHDCTR HDCTR
Managed Element Phase1 Phase2
IPLI
CREATE IPLI
DELETE IPLI
GET IPLI
GET IPLI BASICS
GET IPLI STAT
GETINFO IPLI
GETRELATIONSHIP IPLI
PING IPLI
SET IPLI
Managed Element Phase1 Phase2
IXLT
GET IXLT STAT
GETINFO IXLT


A30808-X3247-M230-6-7619

81
CML:BSC Introduction
Id:0900d805800c63b3
GETRELATIONSHIP IXLT
GETTEST IXLT
LOCK IXLT
PERFTEST IXLT
STOPTEST IXLT
UNLOCK IXLT
Managed Element Phase1 Phase2
LICD
CREATE LICD
DELETE LICD
GET LICD
GET LICD BASICS
GET LICD STAT
GETINFO LICD
GETRELATIONSHIP LICD
GETSUBO LICD
GETTEST LICD
LOCK LICD
PERFTEST LICD
SET LICD
STOPTEST LICD
UNLOCK LICD
Managed Element Phase1 Phase2
LICDS
CREATE LICDS
DELETE LICDS
GET LICDS
GET LICDS STAT
GETRELATIONSHIP
LICDS
GETSUBO LICDS
GETTEST LICDS
LOCK LICDS


82 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
PERFTEST LICDS
STOPTEST LICDS
UNLOCK LICDS
Managed Element Phase1 Phase2
LMT-INTERNAL g This object is not visible on the Graphical User Inter-
face but its commands are used in the DBAEM tool.
ECHO LMT-INTERNAL
EXEC LMT-INTERNAL
SET LMT-INTERNAL
Managed Element Phase1 Phase2
LPDLM
CREATE LPDLM
DELETE LPDLM
GET LPDLM
GET LPDLM BASICS
GET LPDLM STAT
GETINFO LPDLM
GETRELATIONSHIP
LPDLM
GETSUBO LPDLM
SET LPDLM
Managed Element Phase1 Phase2
LPDLR
GET LPDLR STAT
GETINFO LPDLR
GETRELATIONSHIP
LPDLR
GETSUBO LPDLR
Managed Element Phase1 Phase2


A30808-X3247-M230-6-7619

83
CML:BSC Introduction
Id:0900d805800c63b3
LPDLS
CREATE LPDLS
DELETE LPDLS
GET LPDLS
GET LPDLS BASICS
GET LPDLS STAT
GETINFO LPDLS
GETRELATIONSHIP
LPDLS
GETSUBO LPDLS
SET LPDLS
Managed Element Phase1 Phase2
MEL
GET MEL
GET MEL BASICS
SET MEL
Managed Element Phase1 Phase2
MEMT
GET MEMT STAT
GETRELATIONSHIP
MEMT
GETSUBO MEMT
GETTEST MEMT
LOCK MEMT
PERFTEST MEMT
STOPTEST MEMT
SWITCH MEMT
UNLOCK MEMT
Managed Element Phase1 Phase2
MPCC
GET MPCC STAT


84 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GETINFO MPCC
GETRELATIONSHIP
MPCC
GETSUBO MPCC
GETTEST MPCC
LOCK MPCC
PERFTEST MPCC
STOPTEST MPCC
SWITCH MPCC
UNLOCK MPCC
Managed Element Phase1 Phase2
NEYESUSW
GET NEYESUSW
GET NEYESUSW BASICS
GET NEYESUSW STAT
GETINFO NEYESUSW
NEDOWNLOAD
NEYESUSW
NEDOWNLOADABO
NEYESUSW
Managed Element Phase1 Phase2
NSVC
CREATE NSVC
DELETE NSVC
GET NSVC
GET NSVC BASICS
GET NSVC STAT
GETINFO NSVC
GETRELATIONSHIP NSVC
GETSUBO NSVC
LOCK NSVC
UNLOCK NSVC


A30808-X3247-M230-6-7619

85
CML:BSC Introduction
Id:0900d805800c63b3
Managed Element Phase1 Phase2
NSVCIP
GET NSVCIP STAT
GETRELATIONSHIP
NSVCIP
GETSUBO NSVCIP
Managed Element Phase1 Phase2
NSVLIP
CREATE NSVLIP
DELETE NSVLIP
GET NSVLIP
GET NSVLIP BASICS
GET NSVLIP STAT
GETRELATIONSHIP
NSVLIP
GETSUBO NSVLIP
LOCK NSVLIP
SET NSVLIP
UNLOCK NSVLIP
Managed Element Phase1 Phase2
NTW
FORCSYNC NTW
GET NTW STAT
GETRELATIONSHIP NTW
GETSUBO NTW
GETSYNC NTW
GETTEST NTW
LOCK NTW
PERFTEST NTW
STOPTEST NTW
SWITCH NTW
UNLOCK NTW


86 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
UPDATETUNE NTW
Managed Element Phase1 Phase2
NUC
CREATE NUC
DELETE NUC
GET NUC
GET NUC BASICS
GET NUC STAT
GETRELATIONSHIP NUC
Managed Element Phase1 Phase2
OMAL
CREATE OMAL
DELETE OMAL
GET OMAL
GET OMAL BASICS
GET OMAL X25INFO
GET OMAL STAT
GETRELATIONSHIP
OMAL
GETSUBO OMAL
SET OMAL
Managed Element Phase1 Phase2
OPC
CREATE OPC
DELETE OPC
GET OPC
GET OPC BASICS
GET OPC MTL2
GET OPC MTL3
GETINFO OPC
SET OPC


A30808-X3247-M230-6-7619

87
CML:BSC Introduction
Id:0900d805800c63b3
Managed Element Phase1 Phase2
PCMA
CREATE PCMA
DELETE PCMA
GET PCMA
GET PCMA BASICS
GET PCMA PCM24
GET PCMA PCM30
GET PCMA STAT
GETINFO PCMA
GETRELATIONSHIP
PCMA
GETSUBO PCMA
LOCK PCMA
SHUTDOWN PCMA
UNLOCK PCMA
Managed Element Phase1 Phase2
PCMB
CREATE PCMB
DELETE PCMB
GET PCMB
GET PCMB BASICS
GET PCMB PCM24
GET PCMB PCM30
GET PCMB STAT
GETINFO PCMB
GETREDSTAT PCMB
GETRELATIONSHIP
PCMB
GETSUBO PCMB
LOCK PCMB
SET PCMB
UNLOCK PCMB


88 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
Managed Element Phase1 Phase2
PCMG
CREATE PCMG
DELETE PCMG
GET PCMG
GET PCMG BASICS
GET PCMG PCM24
GET PCMG PCM30
GET PCMG STAT
GETINFO PCMG
GETRELATIONSHIP
PCMG
GETSUBO PCMG
LOCK PCMG
SET PCMG
UNLOCK PCMG
Managed Element Phase1 Phase2
PCMS
CREATE PCMS
DELETE PCMS
GET PCMS
GET PCMS BASICS
GET PCMS PCM24
GET PCMS PCM30
GET PCMS STAT
GETINFO PCMS
GETREDSTAT PCMS
GETRELATIONSHIP
PCMS
GETSUBO PCMS
LOCK PCMS
SET PCMS
UNLOCK PCMS


A30808-X3247-M230-6-7619

89
CML:BSC Introduction
Id:0900d805800c63b3
Managed Element Phase1 Phase2
PCU
CREATE PCU
DELETE PCU
GET PCU
GET PCU BASICS
GET PCU STAT
GETINFO PCU
GETRELATIONSHIP PCU
GETSUBO PCU
LOCK PCU
SET PCU
UNLOCK PCU
Managed Element Phase1 Phase2
PPXL
GET PPXL STAT
GETINFO PPXL
GETRELATIONSHIP PPXL
GETSUBO PPXL
GETTEST PPXL
LOCK PPXL
PERFTEST PPXL
STOPTEST PPXL
UNLOCK PPXL
Managed Element Phase1 Phase2
PPXU
GET PPXU STAT
GETINFO PPXU
GETRELATIONSHIP PPXU
GETSUBO PPXU
GETTEST PPXU


90 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
LOCK PPXU
PERFTEST PPXU
STOPTEST PPXU
UNLOCK PPXU
Managed Element Phase1 Phase2
PTPPKF
CREATE PTPPKF
DELETE PTPPKF
GET PTPPKF
GET PTPPKF BASICS
GET PTPPKF STAT
GETINFO PTPPKF
GETRELATIONSHIP
PTPPKF
GETSUBO PTPPKF
LOCK PTPPKF
SET PTPPKF
UNLOCK PTPPKF
Managed Element Phase1 Phase2
PWRC
GET PWRC
GET PWRC BASICS
SET PWRC
Managed Element Phase1 Phase2
PWRD
GET PWRD STAT
GETRELATIONSHIP
PWRD
GETSUBO PWRD
GETTEST PWRD
LOCK PWRD


A30808-X3247-M230-6-7619

91
CML:BSC Introduction
Id:0900d805800c63b3
PERFTEST PWRD
STOPTEST PWRD
UNLOCK PWRD
Managed Element Phase1 Phase2
QSMONBSC
CREATE QSMONBSC
DELETE QSMONBSC
GET QSMONBSC
GET QSMONBSC BASICS
GET QSMONBSC STAT
GETCURRENTVALUE
QSMONBSC
LOCK QSMONBSC
SET QSMONBSC
UNLOCK QSMONBSC
Managed Element Phase1 Phase2
QSMONBTS
CREATE QSMONBTS
DELETE QSMONBTS
GET QSMONBTS
GET QSMONBTS BASICS
GET QSMONBTS STAT
GETCURRENTVALUE
QSMONBTS
LOCK QSMONBTS
SET QSMONBTS
UNLOCK QSMONBTS
Managed Element Phase1 Phase2
QSMONBTSCO
GETINFO QSMONBTSCO


92 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
Managed Element Phase1 Phase2
QSMONGPRS
CREATE QSMONGPRS
DELETE QSMONGPRS
GET QSMONGPRS
GET QSMONGPRS
BASICS
GET QSMONGPRS STAT
GETCURRENTVALUE
QSMONGPRS
LOCK QSMONGPRS
SET QSMONGPRS
UNLOCK QSMONGPRS
Managed Element Phase1 Phase2
QSMONGPRSCO
GETINFO QSMONGPR-
SCO
Managed Element Phase1 Phase2
QSTHRS
CREATE QSTHRS
DELETE QSTHRS
GET QSTHRS
GET QSTHRS BASICS
GETINFO QSTHRS
SET QSTHRS
Managed Element Phase1 Phase2
REMINV
ALIGN REMINV
DNLIDFD REMINV
GET REMINV STAT


A30808-X3247-M230-6-7619

93
CML:BSC Introduction
Id:0900d805800c63b3
LOCK REMINV
UNLOCK REMINV
UPLCIDF REMINV
UPLLIDF REMINV
Managed Element Phase1 Phase2
RFLOOP
CREATE RFLOOP
DELETE RFLOOP
GET RFLOOP
GET RFLOOP BASICS
GET RFLOOP STAT
LOCK RFLOOP
SET RFLOOP
UNLOCK RFLOOP
UPLOADREQ RFLOOP
Managed Element Phase1 Phase2
RNSVLIP
CREATE RNSVLIP
DELETE RNSVLIP
GET RNSVLIP
GET RNSVLIP BASICS
SET RNSVLIP
Managed Element Phase1 Phase2
RSUDB
CREATE RSUDB
DELETE RSUDB
GET RSUDB
GET RSUDB BASICS
GET RSUDB STAT
SET RSUDB


94 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
UPLDFILE RSUDB
Managed Element Phase1 Phase2
RSUEXE
CREATE RSUEXE
DELETE RSUEXE
GET RSUEXE
GET RSUEXE BASICS
GET RSUEXE STAT
Managed Element Phase1 Phase2
RSUPCH
CREATE RSUPCH
DELETE RSUPCH
GET RSUPCH
GET RSUPCH BASICS
GET RSUPCH STAT
LOADPATCH RSUPCH
SET RSUPCH
UNLOADPCH RSUPCH
Managed Element Phase1 Phase2
RSUSWLH
CREATE RSUSWLH
DELETE RSUSWLH
GET RSUSWLH
GET RSUSWLH BASICS
GET RSUSWLH STAT
SET RSUSWLH
Managed Element Phase1 Phase2
SCA


A30808-X3247-M230-6-7619

95
CML:BSC Introduction
Id:0900d805800c63b3
CREATE SCA
DELETE SCA
GET SCA
GET SCA BASICS
GET SCA EICM
GET SCA NMDL
GET SCA STAT
LOCK SCA
SET SCA
UNLOCK SCA
UPLOADREQ SCA
Managed Element Phase1 Phase2
SCANBSC
ADD SCANBSC
CREATE SCANBSC
DELETE SCANBSC
GET SCANBSC
GET SCANBSC BASICS
GET SCANBSC STAT
GETCURRENTVALUES
SCANBSC
LOCK SCANBSC
REMOVE SCANBSC
SET SCANBSC
UNLOCK SCANBSC
Managed Element Phase1 Phase2
SCANBTS
ADD SCANBTS
CREATE SCANBTS
DELETE SCANBTS
GET SCANBTS
GET SCANBTS BASICS
GET SCANBTS STAT


96 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GETCURRENTVALUES
SCANBTS
LOCK SCANBTS
REMOVE SCANBTS
SET SCANBTS
UNLOCK SCANBTS
Managed Element Phase1 Phase2
SCANBTSE
ADD SCANBTSE
CREATE SCANBTSE
DELETE SCANBTSE
GET SCANBTSE
GET SCANBTSE BASICS
GET SCANBTSE STAT
LOCK SCANBTSE
REMOVE SCANBTSE
SET SCANBTSE
UNLOCK SCANBTSE
Managed Element Phase1 Phase2
SCANBTSIHO
ADD SCANBTSIHO
CREATE SCANBTSIHO
DELETE SCANBTSIHO
GET SCANBTSIHO
GET SCANBTSIHO
BASICS
GET SCANBTSIHO STAT
GETCURRENTVALUES
SCANBTSIHO
LOCK SCANBTSIHO
REMOVE SCANBTSIHO
SET SCANBTSIHO
UNLOCK SCANBTSIHO


A30808-X3247-M230-6-7619

97
CML:BSC Introduction
Id:0900d805800c63b3
Managed Element Phase1 Phase2
SCANBTSM
ADD SCANBTSM
CREATE SCANBTSM
DELETE SCANBTSM
GET SCANBTSM
GET SCANBTSM BASICS
GET SCANBTSM STAT
LOCK SCANBTSM
REMOVE SCANBTSM
SET SCANBTSM
UNLOCK SCANBTSM
Managed Element Phase1 Phase2
SCANBTSOHOI
ADD SCANBTSOHOI
CREATE SCANBTSOHOI
DELETE SCANBTSOHOI
GET SCANBTSOHOI
GET SCANBTSOHOI
BASICS
GET SCANBTSOHOI STAT
GETCURRENTVALUES
SCANBTSOHOI
LOCK SCANBTSOHOI
REMOVE SCANBTSOHOI
SET SCANBTSOHOI
UNLOCK SCANBTSOHOI
Managed Element Phase1 Phase2
SCANBTSOHON
ADD SCANBTSOHON
CREATE SCANBTSOHON
DELETE SCANBTSOHON


98 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GET SCANBTSOHON
GET SCANBTSOHON
BASICS
GET SCANBTSOHON
STAT
GETCURRENTVALUES
SCANBTSOHON
LOCK SCANBTSOHON
REMOVE SCANBTSOHON
SET SCANBTSOHON
UNLOCK SCANBTSOHON
Managed Element Phase1 Phase2
SCANBTSOHOS
ADD SCANBTSOHOS
CREATE SCANBTSOHOS
DELETE SCANBTSOHOS
GET SCANBTSOHOS
GET SCANBTSOHOS
BASICS
GET SCANBTSOHOS
STAT
GETCURRENTVALUES
SCANBTSOHOS
LOCK SCANBTSOHOS
REMOVE SCANBTSOHOS
SET SCANBTSOHOS
UNLOCK SCANBTSOHOS
Managed Element Phase1 Phase2
SCANCHAN
ADD SCANCHAN
CREATE SCANCHAN
DELETE SCANCHAN
GET SCANCHAN
GET SCANCHAN BASICS


A30808-X3247-M230-6-7619

99
CML:BSC Introduction
Id:0900d805800c63b3
GET SCANCHAN STAT
LOCK SCANCHAN
REMOVE SCANCHAN
SET SCANCHAN
UNLOCK SCANCHAN
Managed Element Phase1 Phase2
SCANCO
GETINFO SCANCO
UPLMEAS SCANCO
Managed Element Phase1 Phase2
SCANCTRX
ADD SCANCTRX
CREATE SCANCTRX
DELETE SCANCTRX
GET SCANCTRX
GET SCANCTRX BASICS
GET SCANCTRX STAT
LOCK SCANCTRX
REMOVE SCANCTRX
SET SCANCTRX
UNLOCK SCANCTRX
Managed Element Phase1 Phase2
SCANFBTSM
ADD SCANFBTSM
CREATE SCANFBTSM
DELETE SCANFBTSM
GET SCANFBTSM
GET SCANFBTSM BASICS
GETCURRENTVALUES
SCANFBTSM
LOCK SCANFBTSM


100 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
REMOVE SCANFBTSM
SET SCANFBTSM
UNLOCK SCANFBTSM
Managed Element Phase1 Phase2
SCANGPRS
ADD SCANGPRS
CREATE SCANGPRS
DELETE SCANGPRS
GET SCANGPRS
GET SCANGPRS BASICS
GET SCANGPRS STAT
GETCURRENTVALUES
SCANGPRS
LOCK SCANGPRS
REMOVE SCANGPRS
SET SCANGPRS
UNLOCK SCANGPRS
Managed Element Phase1 Phase2
SCANSS7L
ADD SCANSS7L
CREATE SCANSS7L
DELETE SCANSS7L
GET SCANSS7L
GET SCANSS7L BASICS
GET SCANSS7L STAT
GETCURRENTVALUES
SCANSS7L
LOCK SCANSS7L
REMOVE SCANSS7L
SET SCANSS7L
UNLOCK SCANSS7L


A30808-X3247-M230-6-7619

101
CML:BSC Introduction
Id:0900d805800c63b3
Managed Element Phase1 Phase2
SCANTRX
ADD SCANTRX
CREATE SCANTRX
DELETE SCANTRX
GET SCANTRX
GET SCANTRX BASICS
GET SCANTRX STAT
GETCURRENTVALUES
SCANTRX
LOCK SCANTRX
REMOVE SCANTRX
SET SCANTRX
UNLOCK SCANTRX
Managed Element Phase1 Phase2
SOFTWARE-MAN-
AGEMENT
DNLFILE SOFTWARE-
MANAGEMENT
LOADMPCC SOFTWARE-
MANAGEMENT
UPLBTSLOG SOFTWARE-
MANAGEMENT
UPLFILE SOFTWARE-
MANAGEMENT
UPLTRAULOG
SOFTWARE-MANAGE-
MENT
Managed Element Phase1 Phase2
SS7L
CREATE SS7L
DELETE SS7L


102 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GET SS7L
GET SS7L BASICS
GET SS7L STAT
GETRELATIONSHIP SS7L
GETSUBO SS7L
INHIBIT SS7L
LOCK SS7L
TESTLINK SS7L
UNINHIBIT SS7L
UNLOCK SS7L
Managed Element Phase1 Phase2
SS7S
GET SS7S STAT
GETSUBO SS7S
Managed Element Phase1 Phase2
SUBTSLB
CREATE SUBTSLB
DELETE SUBTSLB
GET SUBTSLB
GET SUBTSLB BASICS
GET SUBTSLB STAT
GETRELATIONSHIP
SUBTSLB
LOCK SUBTSLB
SHUTDOWN SUBTSLB
UNLOCK SUBTSLB
Managed Element Phase1 Phase2
SYNC
CREATE SYNC
DELETE SYNC
GET SYNC


A30808-X3247-M230-6-7619

103
CML:BSC Introduction
Id:0900d805800c63b3
GET SYNC BASICS
GET SYNC STAT
GETRELATIONSHIP SYNC
GETSUBO SYNC
LOCK SYNC
UNLOCK SYNC
Managed Element Phase1 Phase2
SYNCO
GETINFO SYNCO
Managed Element Phase1 Phase2
SYNE
CREATE SYNE
DELETE SYNE
FREQMEAS SYNE FREQMEAS SYNE
GET SYNE
GET SYNE STAT
LOCK SYNE
UNLOCK SYNE
Managed Element Phase1 Phase2
SYSINIT
SYSINIT SYSINIT
Managed Element Phase1 Phase2
TDPC
GET TDPC STAT
GETINFO TDPC
GETRELATIONSHIP TDPC
GETSUBO TDPC
GETTEST TDPC


104 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
LOCK TDPC
PERFTEST TDPC
STOPTEST TDPC
SWITCH TDPC
UNLOCK TDPC
Managed Element Phase1 Phase2
TGTBTS
CREATE TGTBTS
DELETE TGTBTS
GET TGTBTS
GET TGTBTS BASICS
SET TGTBTS
Managed Element Phase1 Phase2
TGTFDD
CREATE TGTFDD
DELETE TGTFDD
GET TGTFDD
GET TGTFDD BASICS
SET TGTFDD
Managed Element Phase1 Phase2
TGTPTPPKF
CREATE TGTPTPPKF
DELETE TGTPTPPKF
GET TGTPTPPKF
GET TGTPTPPKF BASICS
SET TGTPTPPKF
Managed Element Phase1 Phase2
TGTTDD


A30808-X3247-M230-6-7619

105
CML:BSC Introduction
Id:0900d805800c63b3
CREATE TGTTDD
DELETE TGTTDD
GET TGTTDD
GET TGTTDD BASICS
SET TGTTDD
Managed Element Phase1 Phase2
TRACE
CREATE TRACE
DELETE TRACE
GET TRACE
GET TRACE BASICS
GET TRACE STAT
GETINFO TRACE
LOCK TRACE
SHUTDOWN TRACE
UNLOCK TRACE
UPLALLIMSITR TRACE
UPLIMSITR TRACE
Managed Element
TRANSFCTRL No commands are foreseen for this object.
Managed Element Phase1 Phase2
TRAU
CREATE TRAU
DELETE TRAU
GET TRAU
GET TRAU BASICS
GET TRAU TIMER
GET TRAU STAT
GETINFO TRAU
GETRELATIONSHIP TRAU


106 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800c63b3
Introduction
GETSUBO TRAU
LOCK TRAU
SET TRAU
SHUTDOWN TRAU
UNLOCK TRAU
Managed Element Phase1 Phase2
TRAUOSUSW
GET TRAUOSUSW
GET TRAUOSUSW
BASICS
GETINFO TRAUOSUSW
SETRUNBACK TRAUO-
SUSW
Managed Element Phase1 Phase2
TRX
CREATE TRX
DELETE TRX
GET TRX
GET TRX BASICS
GET TRX STAT
GETINFO TRX
GETRELATIONSHIP TRX
GETSUBO TRX
LOCK TRX
SET TRX
SHUTDOWN TRX
UNLOCK TRX
Managed Element Phase1 Phase2
TSLA
GET TSLA
GET TSLA BASICS


A30808-X3247-M230-6-7619

107
CML:BSC Introduction
Id:0900d805800c63b3
GET TSLA STAT
GETRELATIONSHIP TSLA
GETSUBO TSLA
LOCK TSLA
SET TSLA
SHUTDOWN TSLA
UNLOCK TSLA
Managed Element
TSLB No commands are foreseen for this object.
Managed Element Phase1 Phase2
X25A
CREATE X25A
DELETE X25A
GET X25A
GET X25A BASICS
GET X25A STAT
GETINFO X25A
GETRELATIONSHIP X25A
SET X25A
Managed Element Phase1 Phase2
X25D
CREATE X25D
DELETE X25D
GET X25D
GET X25D BASICS
GET X25D STAT
GETINFO X25D
GETRELATIONSHIP X25D
SET X25D


108 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d8058007ce14
Objects and Commands in Alphabetical Order
2 Objects and Commands in Alphabetical
Order
In case of DBA Nack Responses, if no specific Additional Information can be provided
to the operator, the "addInfo" field of the response itself is filled using the format:
Module = 0x00xx, line = yyyy
This information is useful to BSC development to understand quickly why the nack
response occurred.


A30808-X3247-M230-6-7619

109
CML:BSC ADJC
Id:0900d805800d43dc
ADJC
The ADJC (Adjacent Cell) object represents one of the adjacent cells that are to be mon-
itored for handover purposes.
CREATE ADJC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC CREATE
ADJC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the specific parameters for the adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
RXLEVMIN rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
FHORLMO fHORxLevMinOffset
TIMERFHO timerFHO
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
LEVONC levelOffsetNCell
TINHBAKHO timerInhibitBackHo
TINHFAIHO timerInhibitFailHo
CREATE ADJC NAME=BTSM:0..199/BTS:0..23/ADJC:0..63 ,TGTCELL=
[,RXLEVMIN=] [,HOM=] [,HOMSOFF=] [,HOMDTIME=]
[,HOMDOFF=] [,MICROCELL=] [,FHORLMO=] [,TIMER-
FHO=] [,PLNC=] [,PPLNC=] [,LEVONC=] [,TINHBAKHO=]
[,TINHFAIHO=] [,GSUP=] [,GTEMPOFF=] [,GPENTIME=]
[,GRESOFF=] [,GHCSTH=] [,GHCSPC=] [,FULHOC=]
[,FULRXLVMOFF=] [,TRFHOM=] [,BHOFOT=] [,LEVHOM=]
[,QUALLEVHOM=] [,USG=] [,NCGRESOFF=] [,NCGTEM-
POFF=] [,NCGPENTIME=] [,NCC1THADJC=] [,TRFHORX-
LVMOFF=] [,BARINSYSINF10=];


110 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
GSUP gprsSupported
GTEMPOFF gprsTemporaryOffset
GPENTIME gprsPenaltyTime
GRESOFF gprsReselectOffset
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
FULHOC fastULHoCell
FULRXLVMOFF fastULRxLevMinOffset
TRFHOM trafficHandoverMargin
BHOFOT backHoForbiddenTimer
LEVHOM levelHOMargin
QUALLEVHOM qualLevelHoMargin
USG usage
NCGRESOFF ncGprsReselectOffset
NCGTEMPOFF ncGprsTemporaryOffset
NCGPENTIME ncGprsPenaltyTime
NCC1THADJC ncC1ThresholdAdjacent
TRFHORXLVMOFF trafficHoRxLevMinOffset
BARINSYSINF10 barredInSysInfo10
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTS object instance must be already equipped.
The TGTBTS object instance must be already equipped.
If GSUP is TRUE the relative PTPPKF object instance must be
already equipped both in the serving and target cell.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
MAX_ADJC_COMPL_BAND_EXCEEDED
The number of adjacent cells having their BCCHFREQ in the comple-
mentary band exceeds the allowed maximum number.
For more details, see Application Guideline n. 7.
LAST_ADJC_RESERVED_FOR_LOTRACH


A30808-X3247-M230-6-7619

111
CML:BSC ADJC
Id:0900d805800d43dc
When the intracell handovers are MSC controlled (attribute
LOTRACH of HAND object set at FALSE) one of the 32 allowed
active ADJCs is reserved by BSC for LOTRACH handling. So the
operator can configure only 31 active ADJC cells or 30 if at least one
ADJC3G has been created.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
UNSUCCESSFUL_INVALID_TARGET_CELL
The serving cell and the target cell must be different if the adjacent
cell is active, or if the adjacent cell is inactive and LOTRACH is set to
FALSE in the HAND object.
An ADJC with the same serving and target cell already exist.
UNSUCCESSFUL_INVALID_BCCF
The target cell and the serving cell must have different BCCH fre-
quencies when the target cell is different from the serving cell.
TOO_MANY_REFERENCES_TO_TARGET_CELL
The maximum number of adjacent cells for the target cell (96) has
been reached.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
In order to set the GSUP parameter at TRUE value, both the serving
and the target cells must have the relative PTPPKF already
equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the SCA object instance
related to the BTS is in LOCKED state.
See also the Application Guideline n. 5.
UNSUCCESSFUL_BCCF_OUT_OF_RANGE
The selected value for the BCCH frequency is out of range.
For more details, see the Application Guideline n. 6.
BCCH_AND_BSIC_BELONG_TO_ANOTHER_CELL
The ADJC has the same (BBCH, BSIC) pair of another ADJC of the
same BTS.
INCOMP_NESWLOAD_VS_MESSAGE
The following attributes must be set to <NULL> if the SW<60 and
must be set to a value different to <NULL> if SW>=60: LEVHOM,
FULHOC, FULHOM, BHOFOT, TRFHOM.
The FULHOC attribute cannot be set to a value different from NULL
if the superordinate BTSM has a SW<60.
The FULHOC attribute cannot be set to NULL if the superordinate
BTSM has a SW>=60


112 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
Application Guidelines:
1. No administrative state is associated with this object.
2. The attribute penalityPriorityNcell (PPLNC) must be set to a value not smaller than
the attributepriorityLayerNcell (PLNC).
3. The timer TIMERFHO is running on the adjacent cell serving the Directed Retry
signalling procedure: that is the timer is defined in ADJC A-B for Directed Retry from
A to B.
4. The attribute TINHFAIHO should be set at a value greater than the timer BSCT7
(see BSC object) and timer THORQST (see HAND object).
5. If the GSUP is FALSE the following attributes must not be specified: GTEMPOFF,
GPENTIME, GRESOFF, GHCSPC and GHCSTH.
The USG attribute can be set to INACTIVE only if the BTS SW
version is >= 8.0.
UNSUCCESSFUL_WRONG_ADJACENT_SPEC
The handover between GSMR and GSM900/DCS 1800 subnetwork
and viceversa is not allowed.
UNSUCCESSFUL_EXCEEDED_OBJECT_NBR
The maximum number of ADJC (ADJC + ADJC3G) in the system
must be lower or equal than 64 x MAX_NBR_BTSA.
If at least one ADJC3G is equipped the operator can configure up to
31 ADJC.
The maximum number of active ADJCs for BTS must be lower or
equal to 32.
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The maximum number of different frequencies of adjacent cells that
can be included in System Information 5 is:
- 30, if LOTRACH=FALSE in HAND object and one or more
ADJC3Gs are equipped;
- 31, if LOTRACH=FALSE in HAND object and no ADJC3Gs are
equipped;
- 31, if LOTRACH=TRUE in HAND object and one or more ADJC3Gs
are equipped.
-32, otherwise.


A30808-X3247-M230-6-7619

113
CML:BSC ADJC
Id:0900d805800d43dc
6. The BCCHFREQ attribute related to the serving cell SYSID attribute as follows.
They must belong either to the same frequency band or to the complementary bands
in the case of dual-band network (GSMDCS, GSMPCS, GSM850PCS).
In the following table, the allowed frequency ranges allowed as complementary
bands for the ADJC BCCHFREQ attribute depending on BSC NETWTYPE and
serving cell SYSID attribute:
NETWTYPE BTS SYSID Complementary Band
GSMR GSMR ---
GSMDCS BB900 DCS1800 (512-885)
EXT900 DCS1800 (512-885)
DCS1800 EXT900 (0-124, 301-424, 975-
1023)
GSMDCS bcch (0-124, 301-
424, 975-1023)
DCS1800 (512-885)
GSMDCS bcch (512-885) EXT900 (0-124, 301-424, 975-
1023)
GSMPCS BB900 PCS1900 (512-810)
EXT900 PCS1900 (512-810)
PCS1900 EXT900 (0-124, 301-424, 975-
1023)
GSM850PCS GSM850 PCS1900 (512-810)
PCS1900 GSM850 (128-251)
GSM850PCS bcch (128-
251)
PCS1900 (512-810)
GSM850PCS bcch (512-
810)
GSM850 (128-251)
GSM850DCS GSM850 DCS1800 (512-885)
GSM850DCS bcch (128-
251)
DCS1800 (512-885)
GSM850DCS bcch (512-
885)
GSM850 (128-251)
DCS1800 GSM850 (128-251)
GSMRAILPUB GSMR ---
EXT900 DCS1800 (512-885)
BB900 DCS1800 (512-885)
DCS1800 EXT900 (0-124, 301-424, 975-
1023)
GSMDCS bcch (0-124, 301-
424, 975-1023)
DCS1800 (512-885)


114 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
7. The maximum number of adjacent cells having their BCCHFREQ in the complemen-
tary band, with respect to the SYSID of the serving cell, depends on the delta
between the lowest and the highest frequency of the ADJCs belonging to this
subset, as shown in the following table:
8. When creating new ADJC objects it may happen that a TRX issues a failure event
report. This leads to a temporary situation where this TRX does not include the
affected cell in HANDOVER_CONDITION_INDICATION messages. This applies
only for the last cell for which the CREATE command was issued and the failure
event report was generated. The situation is cleared when BSC periodically re-trans-
mits the system informations to the TRX
9. If neighbour cells are created with the same frequency but different BSIC as inde-
cated in the example below:
ADJC-1: BCCHFREQ= 90, BSIC=3-3, USG=SI_2, RXLEVMIN =63, HOM=127 //*
only reselection expected
ADJC-2: BCCHFREQ= 90, BSIC=3-1, USG=SI_5 //* only HO expected
and the USG attribute is set different in a way that for one cell USG is set to SI_2
and for others set to SI_5 or SI_2_5 than for the ADJC with USG set to SI_2 the
RXLEVMIN has to be set to 63, the HOM has to be set to 127 to avoid handovers
towards this cell.
Example of Command Execution:
Create ADJC:NAME=BTSM:0/BTS:0/ADJC:0,TGTCELL=TGTBTS:3,RXLEVMIN=12,
HOM=69,HOMSOFF=0,HOMDTIME=0,HOMDOFF=0,MICROCELL=FALSE, FHOR-
LMO=0,TIMERFHO=4,PLNC=0,PPLNC=0,LEVONC=0,TINHBAKHO=30,
TINHFAIHO=7,GSUP=TRUE,GTEMPOFF=1,GPENTIME=0,GRESOFF=0,
GHCSTH=10,GHCSPC=3,FULHOC=TRUE,FULRXLVMOFF=67, TRFHOM=0,BHO-
FOT=1, LEVHOM=0,USG=SI_2_5, NCGRESOFF=DB00, NCGTEMPOFF=DB00,
NCGPENTIME=SEC000, NCC1THADJC=DB05, TRFHORXLVMOFF=30,
QUALLEVHOM=69, BARINSYSINF10=NO;
GSMDCS bcch (512-885) EXT900 (0-124, 301-424, 975-
1023)
Max Number of ADJC in
complementary Band
Delta
16 Any
17 Any, if frequency 0 is present
18 512
22 256
29 128
All 111 or frequency in BB900 band
NETWTYPE BTS SYSID Complementary Band


A30808-X3247-M230-6-7619

115
CML:BSC ADJC
Id:0900d805800d43dc
DELETE ADJC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC DELETE ADJC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete ADJC:NAME=BTSM:0/BTS:0/ADJC:0;
DELETE ADJC NAME=BTSM:0..199/BTS:0..23/ADJC:0..63;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the SCA object
instance related to the BTS is in LOCKED state.
UNSUCCESSFUL_FREQUENCY_UNDER_MEASURE
The frequency of the ADJC is under measure by the superor-
dinate SCA (NMDLATT<nn>).


116 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
GET ADJC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC GET ADJC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
RXLEVMIN rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
FHORLMO fHORxLevMinOffset
TIMERFHO timerFHO
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
LEVONC levelOffsetNCell
TINHBAKHO timerInhibitBackHo
TINHFAIHO timerInhibitFailHo
GSUP gprsSupported
GTEMPOFF gprsTemporaryOffset
GPENTIME gprsPenaltyTime
GRESOFF gprsReselectOffset
GET ADJC NAME=BTSM:0..199/BTS:0..23/ADJC:0..63 [,REQATTL=
TGTCELL ,RXLEVMIN ,HOM ,HOMSOFF ,HOMDTIME
,HOMDOFF ,MICROCELL ,FHORLMO ,TIMERFHO ,PLNC
,PPLNC ,LEVONC ,TINHBAKHO ,TINHFAIHO ,GSUP
,GTEMPOFF ,GPENTIME ,GRESOFF ,GHCSTH ,GHCSPC
,FULHOC ,FULRXLVMOFF ,TRFHOM ,BHOFOT ,LEVHOM
,QUALLEVHOM ,USG ,NCGRESOFF ,NCGTEMPOFF
,NCGPENTIME ,NCC1THADJC ,TRFHORXLVMOFF
,BARINSYSINF10];


A30808-X3247-M230-6-7619

117
CML:BSC ADJC
Id:0900d805800d43dc
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
FULHOC fastULHoCell
FULRXLVMOFF fastULRxLevMinOffset
TRFHOM trafficHandoverMargin
BHOFOT backHoForbiddenTimer
LEVHOM levelHOMargin
QUALLEVHOM qualLevelHoMargin
USG usage
NCGRESOFF ncGprsReselectOffset
NCGTEMPOFF ncGprsTemporaryOffset
NCGPENTIME ncGprsPenaltyTime
NCC1THADJC ncC1ThresholdAdjacent
TRFHORXLVMOFF trafficHoRxLevMinOffset
BARINSYSINF10 barredInSysInfo10
System Responses:
- Operation Completed
TGTCELL: targetCell
RXLEVMIN: rxLevMinCell
HOM: hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME: hoMarginDelayTime
HOMDOFF: hoMarginDynamicOffset
MICROCELL: microcell
FHORLMO: fHORxLevMinOffset
TIMERFHO: timerFHO
PLNC: priorityLayerNcel
PPLNC: penalityPriorityLayerNcell
LEVONC: levelOffsetNcell
TINHBAKHO: timerInhibitBackHO
TINHFAIHO: timerInhibitFailHO
GSUP gprsSupported
GTEMPOFF: gprsTemporaryOffset
GPENTIME: gprsPenaltyTime
GRESOFF: gprsReselectOffset
GHCSTH: gprsHierarchycalCellStructureThreshold
GHCSPC: gprsHierarchycalCellStructPriorityClass


118 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
GET ADJC BASICS
FULHOC: fastULHoCell
FULRXLVMOFF: fastULRxLevMinOffset
TRFHOM: trafficHandoverMargin
BHOFOT: backHoForbiddenTimer
LEVHOM: levelHOMargin
USG: usage
NCGRESOFF: ncGprsReselecOffset
NCGTEMPOFF: ncGprsTemporaryOffset
NCGPENTIME: NcGprsPenaltyTime
NCC1THADJC: NcC1ThresholdAdjacent
TRFHORXLVMOFF: trafficHoRxLevMinOffset
QUALLEVHOM: qualLevelHoMergin
BARINSYSINF10: barredInSysInfo10
TGTCELL: targetCell
RXLEVMIN: rxLevMinCell
HOM: hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME: hoMarginDelayTime
HOMDOFF: hoMarginDynamicOffset
MICROCELL: microcell
FHORLMO: fHORxLevMinOffset
TIMERFHO: timerFHO
PLNC: priorityLayerNcel
PPLNC: penalityPriorityLayerNcell
LEVONC: levelOffsetNcell
TINHBAKHO: timerInhibitBackHO
TINHFAIHO: timerInhibitFailHO
GSUP gprsSupported
GTEMPOFF: gprsTemporaryOffset
GPENTIME: gprsPenaltyTime
GRESOFF: gprsReselectOffset
GHCSTH: gprsHierarchycalCellStructureThreshold
GHCSPC: gprsHierarchycalCellStructPriorityClass
FULHOC: fastULHoCell


A30808-X3247-M230-6-7619

119
CML:BSC ADJC
Id:0900d805800d43dc
- Operation Failed
Application Guidelines:
None.
GET ADJC BASICS
None.
Example of Command Execution:
Get ADJC:NAME=BTSM:0/BTS:0/ADJC:0,REQATTL=TGTCELL&RXLEVMIN&
HOM&HOMSOFF&HOMDTIME&HOMDOFF&MICROCELL&FHORLMO& TIMER-
FHO&PLNC&PPLNC&LEVONC&TINHBAKHO&TINHFAIHO&GSUP&
GTEMPOFF&GPENTIME&GRESOFF&GHCSTH&GHCSPC&FULHOC&
FULRXLVMOFF& TRFHOM&BHOFOT&LEVHOM&USG&NCGRESOFF&
NCGTEMPOFF&NCGPENTIME&NCC1THADJC&TRFHORXLV-
MOFF&QUALLEVHOM&BARINSYSINF10;
GET ADJC BASICS
Get ADJC BASICS:NAME=BTSM:0/BTS:0/ADJC:0;
GET ADJC BASICS
FULRXLVMOFF: fastULRxLevMinOffset
TRFHOM: trafficHandoverMargin
BHOFOT: backHoForbiddenTimer
LEVHOM: levelHOMargin
USG: usage
NCGRESOFF: ncGprsReselecOffset
NCGTEMPOFF: ncGprsTemporaryOffset
NCGPENTIME: NcGprsPenaltyTime
NCC1THADJC: NcC1ThresholdAdjacent
TRFHORXLVMOFF: trafficHoRxLevMinOffset
QUALLEVHOM: qualLevelHoMargin
BARINSYSINF10: barredInSysInfo10
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET ADJC BASICS NAME=BTSM:0..199/BTS:0..23/ADJC:0..63;


120 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC GET ADJC
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
RXLEVMIN rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
FHORLMO fHORxLevMinOffset
TIMERFHO timerFHO
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
LEVONC levelOffsetNCell
TINHBAKHO timerInhibitBackHo
TINHFAIHO timerInhibitFailHo
GSUP gprsSupported
GTEMPOFF gprsTemporaryOffset
GPENTIME gprsPenaltyTime
GRESOFF gprsReselectOffset
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
FULHOC fastULHoCell
FULRXLVMOFF fastULRxLevMinOffset
TRFHOM trafficHandoverMargin
BHOFOT backHoForbiddenTimer
LEVHOM levelHOMargin
QUALLEVHOM qualLevelHoMargin
USG usage
NCGRESOFF ncGprsReselectOffset


A30808-X3247-M230-6-7619

121
CML:BSC ADJC
Id:0900d805800d43dc
NCGTEMPOFF ncGprsTemporaryOffset
NCGPENTIME ncGprsPenaltyTime
NCC1THADJC ncC1ThresholdAdjacent
TRFHORXLVMOFF trafficHoRxLevMinOffset
BARINSYSINF10 barredInSysInfo10
System Responses:
See GET ADJC
Application Guidelines:
See GET ADJC
Example of Command Execution:
See GET ADJC
SET ADJC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC SET ADJC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters for adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
RXLEVMIN rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
SET ADJC NAME=BTSM:0..199/BTS:0..23/ADJC:0..63 [,TGTCELL=]
[,RXLEVMIN=] [,HOM=] [,HOMSOFF=] [,HOMDTIME=]
[,HOMDOFF=] [,MICROCELL=] [,FHORLMO=] [,TIMER-
FHO=] [,PLNC=] [,PPLNC=] [,LEVONC=] [,TINHBAKHO=]
[,TINHFAIHO=] [,GSUP=] [,GTEMPOFF=] [,GPENTIME=]
[,GRESOFF=] [,GHCSTH=] [,GHCSPC=] [,FULHOC=]
[,FULRXLVMOFF=] [,TRFHOM=] [,BHOFOT=] [,LEVHOM=]
[,QUALLEVHOM=] [,USG=] [,NCGRESOFF=] [,NCGTEM-
POFF=] [,NCGPENTIME=] [,NCC1THADJC=] [,TRFHORX-
LVMOFF=] [,BARINSYSINF10=];


122 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
MICROCELL microcell
FHORLMO fHORxLevMinOffset
TIMERFHO timerFHO
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
LEVONC levelOffsetNCell
TINHBAKHO timerInhibitBackHo
TINHFAIHO timerInhibitFailHo
GSUP gprsSupported
GTEMPOFF gprsTemporaryOffset
GPENTIME gprsPenaltyTime
GRESOFF gprsReselectOffset
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
FULHOC fastULHoCell
FULRXLVMOFF fastULRxLevMinOffset
TRFHOM trafficHandoverMargin
BHOFOT backHoForbiddenTimer
LEVHOM levelHOMargin
QUALLEVHOM qualLevelHoMargin
USG usage
NCGRESOFF ncGprsReselectOffset
NCGTEMPOFF ncGprsTemporaryOffset
NCGPENTIME ncGprsPenaltyTime
NCC1THADJC ncC1ThresholdAdjacent
TRFHORXLVMOFF trafficHoRxLevMinOffset
BARINSYSINF10 barredInSysInfo10
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTS object instance must be already equipped.
The TGTBTS object instance must be already equipped.
If GSUP is TRUE the relative PTPPKF object instance must be
already equipped both in the serving and target cell.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

123
CML:BSC ADJC
Id:0900d805800d43dc
The object instance must be already equipped.
MAX_ADJC_COMPL_BAND_EXCEEDED
The number of the adjacent cells having their BCCHFREQ in the
complementary band exceed the allowed maximum number.
For more details, see Application Guidelines n. 8.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
UNSUCCESSFUL_INVALID_TARGET_CELL
The serving cell and the target cell must be different if the adjacent
cell is active, or if the adjacent cell is inactive and LOTRACH is set to
FALSE in the HAND object.
An ADJC with the same serving and target cell already exist.
UNSUCCESSFUL_INVALID_BCCF
The target and serving cell must have different BCCH frequencies
when the target cell is different from the serving cell.
TOO_MANY_REFERENCES_TO_TARGET_CELL
The maximum number of adjacent cells for the target cell (96) has
been reached.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
In order to set the GSUP parameter at TRUE value, both the serving
and the target cells must have the relative PTPPKF already
equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the SCA object instance
related to the BTS is in LOCKED state.
See also the Application Guideline n. 5.
UNSUCCESSFUL_BCCF_OUT_OF_RANGE
The selected value for the BCCH frequency is out of range. For more
details, see the Application Guideline n. 7.
BCCH_AND_BSIC_BELONG_TO_ANOTHER_CELL
The ADJC has the same (BBCH, BSIC) pair of another ADJC of the
same BTS.
INCOMP_NESWLOAD_VS_MESSAGE
The following attributes must be set to <NULL> if the SW<60 and
must be set to a value different to <NULL> if SW>=60: LEVHOM,
FULHOC, FULHOM, BHOFOT, TRFHOM.
The USG attribute can be set to inactive only if the BTS SW version
is >=8.0.


124 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
Application Guidelines:
1. No administrative state is associated with this object.
2. The attribute penalityPriorityNcell (PPLNC) must be set at a value not smaller than
the attributepriorityLayerNcell (PLNC).
3. The timer TIMERFHO is running on the adjacent cell serving the Directed Retry
signalling procedure: that is the timer is defined in ADJC A-B for Directed Retry from
A to B.
4. The attribute TINHFAIHO should be set at a value greater than the timer BSCT7
(see BSC object) and timer THORQST (see HAND object).
5. If the GSUP is FALSE the following attributes must not be specified: GTEMPOFF,
GPENTIME, GRESOFF, GHCSPC and GHCSTH.
6. If the related BTS is a GSM (DCS) cell, it is possible to create no more than 16 ADJC
MOs in the DCS (GSM) complementary band.
The FULHOC attribute cannot be set to a value different from NULL
if the superordinate BTSM has a SW<60.
The FULHOC attribute cannot be set to NULL if the superordinate
BTSM has a SW>=60
UNSUCCESSFUL_WRONG_ADJACENT_SPEC
The handover between GSMR and GSM900/DCS 1800 subnetwork
and viceversa is not allowed.
UNSUCCESSFUL_EXCEEDED_OBJECT_NBR
The maximum number of ADJC (ADJC + ADJC3G) in the system
must be lower or equal than 64 x MAX_NBR_BTSA.
If at least one ADJC3G is equipped the operator can configure up to
31 ADJC.
UNSUCCESSFUL_FREQUENCY_UNDER_MEASURE
The frequency of the ADJC is under measure by the superordinate
SCA (NMDLATT<nn>).
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The maximum number of different frequencies of adjacent cells that
can be included in System Information 5 is:
- 30, if LOTRACH=FALSE in HAND object and one or more
ADJC3Gs are equipped;
- 31, if LOTRACH=FALSE in HAND object and no ADJC3Gs are
equipped;
- 31, if LOTRACH=TRUE in HAND object and one or more ADJC3Gs
are equipped.
-32, otherwise.


A30808-X3247-M230-6-7619

125
CML:BSC ADJC
Id:0900d805800d43dc
7. The BCCHFREQ attribute related to the serving cell SYSID attribute as follows.
They must belong either to the same frequency band or to the complementary bands
in the case of dual-band network (GSMDCS, GSMPCS, GSM850PCS).
In the following table, the allowed frequency ranges allowed as complementary
bands for the ADJC BCCHFREQ attribute depending on BSC NETWTYPE and
serving cell SYSID attribute:
8. The maximum number of adjacent cells having their BCCHFREQ in the complemen-
tary band with respect to the serving cell's SYSID depends on the delta between the
NETWTYPE BTS SYSID Complementary Band
GSMR GSMR ---
GSMDCS BB900 DCS1800 (512-885)
EXT900 DCS1800 (512-885)
DCS1800 EXT900 ( 0-124, 301-424, 975-
1023)
GSMDCS bcch (0-124, 301-
424, 975-1023)
DCS1800 (512-885)
GSMDCS bcch (512-885) EXT900 (0-124, 301-424, 975-
1023)
GSMPCS BB900 PCS1900 (512-810)
EXT900 PCS1900 (512-810)
PCS1900 EXT900 (0-124, 301-424, 975-
1023)
GSM850PCS GSM850 PCS1900 (512-810)
PCS1900 GSM850 (128-251)
GSM850PCS bcch (128-251) PCS1900 (512-810)
GSM850PCS bcch (512-810) GSM850 (128-251)
GSM850DCS GSM850 DCS1800 (512-885)
GSM850DCS bcch (128-251) DCS1800 (512-885)
GSM850DCS bcch (512-885) GSM850 (128-251)
DCS1800 GSM850 (128-251)
GSMRAILPUB GSMR ---
EXT900 DCS1800 (512-885)
BB900 DCS1800 (512-885)
DCS1800 EXT900 (0-124, 301-424, 975-
1023)
GSMDCS bcch (0-124, 301-
424, 975-1023)
DCS1800 (512-885)
GSMDCS bcch (512-885) EXT900 (0-124, 301-424, 975-
1023)


126 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d43dc
ADJC
lower and the highest frequency of the ADJC belonging to this subset, as shown in
the following table.
9. If neighbour cells are created with the same frequency but different BSIC as inde-
cated in the example below:
ADJC-1: BCCHFREQ= 90, BSIC=3-3, USG=SI_2, RXLEVMIN =63, HOM=127 //*
only reselection expected
ADJC-2: BCCHFREQ= 90, BSIC=3-1, USG=SI_5 //* only HO expected
and the USG attribute is set different in a way that for one cell USG is set to SI_2
and for others set to SI_5 or SI_2_5 than for the ADJC with USG set to SI_2 the
RXLEVMIN has to be set to 63, the HOM has to be set to 127 to avoid handovers
towards this cell.
Example of Command Execution:
Set ADJC:NAME=BTSM:0/BTS:0/ADJC:0,TGTCELL=BTS:3,RXLEVMIN=12,
HOM=69,HOMSOFF=0,HOMDTIME=0,HOMDOFF=0,MICROCELL=FALSE, FHOR-
LMO=0,TIMERFHO=4,PLNC=0,PPLNC=0,LEVONC=0,TINHBAKHO=30,
TINHFAIHO=7,GSUP=TRUE,GTEMPOFF=1,GPENTIME=0,GRESOFF=0,
GHCSTH=10,GHCSPC=3,FULHOC=TRUE,FULRXLVMOFF=67, TRFHOM=0,BHO-
FOT=1,LEVHOM=0,USG=SI_2_5, NCGRESOFF=DB00, NCGTEMPOFF=DB00,
NCGPENTIME=SEC000, NCC1THADJC=DB05,TRFHORXLVMOFF=30,
QUALLEVHOM=69, BARINSYSINF10=NO;
Max Number of ADJC in
Complementary Band
Delta
16 Any
17 Any, if frequency 0 is present
18 512
22 256
29 128
All 111 or frequency in BB900 band


A30808-X3247-M230-6-7619

127
CML:BSC ADJC3G
Id:0900d805800d41e4
ADJC3G
CREATE ADJC3G
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G CREATE
ADJC3G
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the specific parameters for adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
USRSCP umtsSuffRscp
USECNO umtsSuffEcNo
UMECNO umtsMinEcNo
UADJ umtsAdjust
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
RXLEVMINC rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
TINHFAIHO timerInhibitFailHo
USRSCPNCRESEL umtsSuffRscpNcResel
USECNONCRESEL umtsSuffEcNoNcResel
GMICROCU gprsMicrocellUmts
CREATE ADJC3G NAME=BTSM:0..199/BTS:0..23/ADJC3G:0..63 ,TGT-
CELL= [,USRSCP=] [,USECNO=] [,UMECNO=] [,UADJ=]
[,PLNC=] [,PPLNC=] [,RXLEVMINC=] [,HOM=] [,HOM-
SOFF=] [,HOMDTIME=] [,HOMDOFF=] [,MICROCELL=]
[,TINHFAIHO=] [,USRSCPNCRESEL=] [,USECNONCRE-
SEL=] [,GMICROCU=] [,TUESP=];


128 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41e4
ADJC3G
TUESP timerUeSpeed
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTS object instance must be already equipped.
The TGTFDD (or TGTTDD) object instance pointed by ADJC3G
instance must be already equipped.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_WRONG_ME_ID
The TGTCELL must be a TGTFDD or TGTTDD object.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
The maximum number of ADJC (ADJC + ADJC3G) for system must
be lower than or equal to 64 * (MAX_nbr_btse).
TOO_MANY_REFERENCES_TO_A_TARGET_CELL
The maximum number of adjacent cells (96) for the target cell has
been reached.
UNSUCCESSFUL_INVALID_ATTRIBUTES
For each BTS, it is allowed to create up to 64 ADJC3G instances
between FDD and TDD adjacent cells:
- FDD adjacent cells on up to 3 FDD frequencies, with a maximum of
32 cells per frequency;
- TDD adjacent cells on up to 3 TDD frequencies, with a maximum of
32 cells per frequency.
The NBLKACGR attribute (see BTS object) must be set at a value >
0 when one UTRAN neighbour cell has been configured.
A BTS cannot have two FDD ADJC3Gs with the same (FDDARFCN,
FDDSCRMC) pair.
A BTS cannot have two TDD ADJC3Gs with the same (TDDARFCN,
TDDCPAR) pair.
UNSUCCESSFUL_INVALID_TARGET_CELL
An ADJC3G with the same serving and target cell already exists.
LAST_ADJC_RESERVED_FOR_LOTRACH
In order to create an ADJC3G, the ADJC of the cell must be less than
32 or 31 if LOTRACH is FALSE.


A30808-X3247-M230-6-7619

129
CML:BSC ADJC3G
Id:0900d805800d41e4
Application Guidelines:
None.
Example of Command Execution:
Create ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0,TGTCELL=TGTFDD:6,
USRSCP=9,USECNO=5,UMECNO=44,UADJ=5,PLNC=3,PPLNC=3,
RXLEVMINC=33,HOM=111,HOMSOFF=112,HOMDTIME=89,HOMDOFF=56,
MICROCELL=TRUE,TINHFAIHO=5, USRSCPNCRESEL=8, USECNONCRESEL=19,
GMICROCU=FALSE, TUESP=4;
DELETE ADJC3G
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G DELETE
ADJC3G
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The maximum number of different frequencies of adjacent cells that
can be included in System Information 5 is:
- 30, if LOTRACH=FALSE in HAND object and one or more
ADJC3Gs are equipped;
- 31, if LOTRACH=FALSE in HAND object and no ADJC3Gs are
equipped;
- 31, if LOTRACH=TRUE in HAND object and one or more ADJC3Gs
are equipped.
-32, otherwise.
DELETE ADJC3G NAME=BTSM:0..199/BTS:0..23/ADJC3G:0..63;


130 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41e4
ADJC3G
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0;
GET ADJC3G
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G GET
ADJC3G
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
USRSCP umtsSuffRscp
USECNO umtsSuffEcNo
UMECNO umtsMinEcNo
UADJ umtsAdjust
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
RXLEVMINC rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET ADJC3G NAME=BTSM:0..199/BTS:0..23/ADJC3G:0..63
[,REQATTL= TGTCELL ,USRSCP ,USECNO ,UMECNO
,UADJ ,PLNC ,PPLNC ,RXLEVMINC ,HOM ,HOMSOFF
,HOMDTIME ,HOMDOFF ,MICROCELL ,TINHFAIHO ,USR-
SCPNCRESEL ,USECNONCRESEL ,GMICROCU
,TUESP];


A30808-X3247-M230-6-7619

131
CML:BSC ADJC3G
Id:0900d805800d41e4
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
TINHFAIHO timerInhibitFailHo
USRSCPNCRESEL umtsSuffRscpNcResel
USECNONCRESEL umtsSuffEcNoNcResel
GMICROCU gprsMicrocellUmts
TUESP timerUeSpeed
System Responses:
- Operation Completed
GET ADJC3G BASICS
TGTCELL: targetCell
USRSCP: umtsSuffRscp
USECNO: umtsSuffEcNo
UMECNO: umtsMinEcNo
UADJ: umtsAdijust
PLNC: priorityLayerNCell
PPLNC: penalityPriorityLayerNCell
RXLEVMINC: rxLevMinCell
HOM: hoMargin
HOMSOFF: hoMarginStaticOffset
HOMDTIME: hoMarginDelayTime
HOMDOFF: hoMarginDynamicOffset
MICROCELL: microcell
TINHFAIHO: timerInhibitFailHo
USRSCPNCRESEL: umtsSuffRscpNcResel
USECNONCRESEL: umtsSuffEcNoResel
GMICROCU: gprsMicrocellUmts
TUESP: timerUeSpeed
TGTCELL: targetCell
USRSCP: umtsSuffRscp
USECNO: umtsSuffEcNo
UMECNO: umtsMinEcNo
UADJ: umtsAdijust


132 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41e4
ADJC3G
- Operation Failed
Application Guidelines:
None.
GET ADJC3G BASICS
None.
Example of Command Execution:
Get ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0,REQATTL=TGTCELL&USRSCP&
USECNO&UMECNO&UADJ&PLNC&PPLNC&RXLEVMINC&HOM&HOMSOFF&
HOMDTIME&HOMDOFF&MICROCELL&TINHFAIHO&USRSCPNCRESEL&USEC-
NONCRESEL&GMICROCU&TUESP;
GET ADJC3G BASICS
Get ADJC3G BASICS:NAME=BTSM:0/BTS:0/ADJC3G:0;
GET ADJC3G BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G GET
ADJC3G BASICS
PLNC: priorityLayerNCell
PPLNC: penalityPriorityLayerNCell
RXLEVMINC: rxLevMinCell
HOM: hoMargin
HOMSOFF: hoMarginStaticOffset
HOMDTIME: hoMarginDelayTime
HOMDOFF: hoMarginDynamicOffset
MICROCELL: microcell
TINHFAIHO: timerInhibitFailHo
USRSCPNCRESEL: umtsSuffRscpNcResel
USECNONCRESEL: umtsSuffEcNoResel
GMICROCU: gprsMicrocellUmts
TUESP: timerUeSpeed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET ADJC3G BASICS NAME=BTSM:0..199/BTS:0..23/ADJC3G:0..63;


A30808-X3247-M230-6-7619

133
CML:BSC ADJC3G
Id:0900d805800d41e4
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
USRSCP umtsSuffRscp
USECNO umtsSuffEcNo
UMECNO umtsMinEcNo
UADJ umtsAdjust
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
RXLEVMINC rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
TINHFAIHO timerInhibitFailHo
USRSCPNCRESEL umtsSuffRscpNcResel
USECNONCRESEL umtsSuffEcNoNcResel
GMICROCU gprsMicrocellUmts
TUESP timerUeSpeed
System Responses:
See GET ADJC3G
Application Guidelines:
See GET ADJC3G
Example of Command Execution:
See GET ADJC3G


134 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41e4
ADJC3G
SET ADJC3G
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS ADJC3G SET
ADJC3G
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters for adjacent cells of a given cell.
Long Names:
NAME Addres of the managed object
TGTCELL targetCell
USRSCP umtsSuffRscp
USECNO umtsSuffEcNo
UMECNO umtsMinEcNo
UADJ umtsAdjust
PLNC priorityLayerNCell
PPLNC penaltyPriorityLayerNCell
RXLEVMINC rxLevMinCell
HOM hoMargin
HOMSOFF hoMarginStaticOffset
HOMDTIME hoMarginDelayTime
HOMDOFF hoMarginDynamicOffset
MICROCELL microcell
TINHFAIHO timerInhibitFailHo
USRSCPNCRESEL umtsSuffRscpNcResel
USECNONCRESEL umtsSuffEcNoNcResel
GMICROCU gprsMicrocellUmts
TUESP timerUeSpeed
System Responses:
- Operation Completed
Successful
SET ADJC3G NAME=BTSM:0..199/BTS:0..23/ADJC3G:0..63 [,TGT-
CELL=] [,USRSCP=] [,USECNO=] [,UMECNO=] [,UADJ=]
[,PLNC=] [,PPLNC=] [,RXLEVMINC=] [,HOM=] [,HOM-
SOFF=] [,HOMDTIME=] [,HOMDOFF=] [,MICROCELL=]
[,TINHFAIHO=] [,USRSCPNCRESEL=] [,USECNONCRE-
SEL=] [,GMICROCU=] [,TUESP=];


A30808-X3247-M230-6-7619

135
CML:BSC ADJC3G
Id:0900d805800d41e4
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set ADJC3G:NAME=BTSM:0/BTS:0/ADJC3G:0,TGTCELL=TGTFDD:6,USRSCP=9,
USECNO=5,UMECNO=44,UADJ=5,PLNC=3,PPLNC=3,RXLEVMINC=33,HOM=111,
HOMSOFF=112,HOMDTIME=89,HOMDOFF=56,MICROCELL=TRUE,TINH-
FAIHO=5, USRSCPNCRESEL=8, USECNONCRESEL=19, GMICROCU=FALSE,
TUESP=4;
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The TGTFDD (or TGTTDD) object instance pointed by ADJC3G
instance must be already equipped.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_TARGET_CELL
An ADJC3G with the same serving and target cell already exists.
UNSUCCESSFUL_INVALID_ATTRIBUTES
For each BTS, it is allowed to create up to 64 ADJC3G instances
divided into:
- FDD adjacent cells on up to 3 FDD frequencies, with a maximum of
32 cells per frequency;
- TDD adjacent cells on up to 3 TDD frequencies, with a maximum of
32 cells per frequency.
A BTS cannot have two FDD ADJC3Gs with the same (FDDARFCN,
FDDSCRMC) pair.
A BTS cannot have two TDD ADJC3Gs with the same (TDDARFCN,
TDDCPAR) pair.
TOO_MANY_REFERENCES_TO_A_TARGET_CELL
The maximum number of adjacent cells (96) for the target cell has
been reached.
UNSUCCESSFUL_WRONG_ME_ID
The TGTCELL must be a TGTFDD or TGTTDD object.


136 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
BSC
The BSC (Base Station Controller) object represents the controller of the BTS equip-
ments.
BRIDGE BSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC BRIDGE BSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command includes all information needed to address to BSC different configuration
command.
Long Names:
NAME Addres of the managed object
RELCMD relatedCommand
RELOBJ relatedObject
ATT1 attribute1
System Responses:
- Operation Completed
- Operation Failed
Application Guidelines:
None.
BRIDGE BSC NAME=BSC:0..0 ,RELCMD= ,RELOBJ= [,ATT<n>=];
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTE
One or more attributes have been incorrectly set.
UNSUCCESSFUL_INVALID_COMMAND
The object specified by the RELOBJ does not support the BRIDGE
functionality.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


A30808-X3247-M230-6-7619

137
CML:BSC BSC
Id:0900d805800d4401
Example of Command Execution:
Bridge BSC:NAME=BSC:0,RELCMD=SET, RELOBJ=BTSM:2/BTS:3,ATT1="string1"-
NULL(0), ATT2="string2"-i(255), ATT3="string3"-b(TRUE), ATT4="string4"-s(OK),
ATT5="string5"-p(BTSM:5/BTS:1);
GET BSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the global parameters, previously entered through the
SET BSC command, or the default values if the SET BSC command was not submitted.
GET BSC NAME=BSC:0..0 [,REQATTL= NETWTYPE ,T3122
,ERRACT ,ENCALSUP ,MAXNCELL ,MSCV ,OVLSTTHR
,OVLENTHR ,BSCOVLH ,BTSOVLH ,MSCOVLH ,EISDC-
CHHO ,ENFORCHO ,NTWCARD ,AMONTH ,ASMONTH
,SPENLAW ,PCMTYPE ,EFRSUPP ,CICFM ,EPOOL
,MSCPOOL ,HRSPEECH ,HRDATA ,SPEED145
,ENHSCSD ,ENFOIAHO ,HOSYNC ,ASUBISAT ,AISAT
,EPREHSCSD ,MAFIRACHO ,MADGRLV ,NOTFACCH
,MNTBMASK ,DLAPDOVL ,MEDAFUST ,HDCFUPE
,MEDAFUPE ,MASCLOGFS ,CFS ,IMSIFSIZ ,HDCFS
,ALRMSEVBTS ,ALRMSEVBTSM ,ALRMSEVCBCL
,ALRMSEVLPDLM ,ALRMSEVLPDLR ,ALRMSEVLPDLS
,ALRMSEVOMAL ,ALRMSEVPCMA ,ALRMSEVPCMB
,ALRMSEVPCMS ,ALRMSEVTRAU ,ALRMSEVTRX
,ALRMSEVPCU ,ALRMSEVFRL ,ALRMSEVNSVC ,ALRM-
SEVPTPPKF ,ALRMSEVPCMG ,BSCT1 ,BSCT3 ,BSCT4
,BSCT7 ,BSCT8 ,BSCT10 ,BSCT11PUB ,BSCT13 ,BSCT17
,BSCT18 ,BSCT19 ,BSCT20 ,BSCTQHOPUB ,BSCT3121
,TCBCSI ,TRACEMR ,TRACEMG ,TRFCT ,EPA ,CBCPH
,TGUARDTCHSD ,CITASUP ,LCSNSSC ,LCSMONTH
,SIMSCREL99 ,TRFPS ,NCRESELFLAG
,CSCH3CSCH4SUP ,ACCEPTGDEGR ,EUSDCHO ,ALRM-
SEVIPLI ,ESUP ,NECI ,ASCIONECHMDL ,SYSPACKSYS-
SUP ,EUSCNCRESEL ,MISTSTRSH ,CCHANTFACT
,BSCT11WPS ,BSCTQHOWPS ,TYPOFAMC ,TYPOFETH
,ROUIPADD<n> ,SUBNETMASK<n> ,NACCNTWCOR
,TRANSPM ,TDTMWIND ,MAXLAPDMN ,EENHDTMSUP
,T3197 ,PAGCOORCLB ,DGRSTRGYBCNT ,PAGQOV-
LIND];


138 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
Long Names:
NAME Addres of the managed object
NETWTYPE networkType
T3122 waitIndication
ERRACT errorAct
ENCALSUP encryptionAlgorSupport
MAXNCELL maxNCell
MSCV mscVersion
OVLSTTHR ovlStartThreshold
OVLENTHR ovlEndThreshold
BSCOVLH bscOvlHand
BTSOVLH btsOvlHand
MSCOVLH mscOvlHand
EISDCCHHO enableInterSdcchHo
ENFORCHO enforceHo
NTWCARD networkCard
AMONTH aintTchMonitorThresholds
ASMONTH aintSs7MonitorThresholds
SPENLAW speechEncodingLaw
PCMTYPE pcmType
EFRSUPP enhanceFullRateSupport
CICFM cicFormat
EPOOL enablePooling
MSCPOOL mscPooling
HRSPEECH halfRateSpeechSupported
HRDATA halfRateDataSupported
SPEED145 speedSupported_14_5
ENHSCSD enableHSCSD
ENFOIAHO enableForcedIntracellHo
HOSYNC handoverSynchronization
ASUBISAT asubInterfaceOnSatellited
AISAT aInterfaceIsSatellited
EPREHSCSD enablePreemptionHSCSD
MAFIRACHO maxForcedIntraCellHo
MADGRLV maxDowngradeLevel
NOTFACCH notificationOnFACCH
MNTBMASK maintenanceBitMask
DLAPDOVL downlinkLapdOverload
MEDAFUST measurementDataFileUploadStart


A30808-X3247-M230-6-7619

139
CML:BSC BSC
Id:0900d805800d4401
HDCFUPE historyOnDroppedCallsFileUploadPeriod
MEDAFUPE measurementDataFileUploadPeri
MASCLOGFS maxScannerLogFileSize
CFS ctrFileSize
IMSIFSIZ imsiFileSize
HDCFS historyDroppedCallFileSize
ALRMSEVBTS alarmSeverityBts
ALRMSEVBTSM alarmSeverityBtsm
ALRMSEVCBCL alarmSeverityCbcl
ALRMSEVLPDLM alarmSeverityLpdlm
ALRMSEVLPDLR alarmSeverityLpdlr
ALRMSEVLPDLS alarmSeverityLpdls
ALRMSEVOMAL alarmSeverityOmal
ALRMSEVPCMA alarmSeverityPcma
ALRMSEVPCMB alarmSeverityPcmb
ALRMSEVPCMS alarmSeverityPcms
ALRMSEVTRAU alarmSeverityTrau
ALRMSEVTRX alarmSeverityTrx
ALRMSEVPCU alarmSeverityPcu
ALRMSEVFRL alarmSeverityFrl
ALRMSEVNSVC alarmSeverityNsvc
ALRMSEVPTPPKF alarmSeverityPtppkf
ALRMSEVPCMG alarmSeverityPcmg
BSCT1 bscTimer1
BSCT3 bscTimer3
BSCT4 bscTimer4
BSCT7 bscTimer7
BSCT8 bscTimer8
BSCT10 bscTimer10
BSCT11PUB bscTimer11Public
BSCT13 bscTimer13
BSCT17 bscTimer17
BSCT18 bscTimer18
BSCT19 bscTimer19
BSCT20 bscTimer20
BSCTQHOPUB bscTimerQueueHoPublic
BSCT3121 bscTimer3121
TCBCSI timerForCBCServiceInterruption
TRACEMR traceMeasureReport


140 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
TRACEMG traceMeasureGranularity
TRFCT trafficControlTimer
EPA enablePairing
CBCPH CBCphase
TGUARDTCHSD timerGuardTchsd
CITASUP cellIdTimeAdvSupport
LCSNSSC lcsNssCentric
LCSMONTH lCSMonitorTresholds
SIMSCREL99 systemInfoMscRel99
TRFPS trafficPs
NCRESELFLAG ncReselectionFlag
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
ACCEPTGDEGR acceptableGPRSDegradation
EUSDCHO enableUmtsSdcchHo
ALRMSEVIPLI alarmSeverityIpli
ESUP edgeSupport
NECI newEstablishCauseIndication
ASCIONECHMDL asciOneChannelModel
SYSPACKSYSSUP sysInfoPacketSysInfoSupport
EUSCNCRESEL enableUmtsSuffCovNcResel
MISTSTRSH missingTSThreshold
CCHANTFACT cellChangeNotificationActive
BSCT11WPS bscTimer11WPS
BSCTQHOWPS bscTimerQueueHoWPS
TYPOFAMC typeOfAlarmModuleCard
TYPOFETH typeOfEthernet
ROUIPADD<n> routerIPAddress<n>
SUBNETMASK<n> subNetMask<n>
NACCNTWCOR nACCNetworkControlOrder
TRANSPM transparentPerformanceMeasurements
TDTMWIND timerDTMWaitIndicator
MAXLAPDMN maxlapdmNumber
EENHDTMSUP enabledEnhancedDTMSupport
T3197 t3197
PAGCOORCLB pagingCoordinationClassB
DGRSTRGYBCNT downgradeStrategyForBusyCounting
PAGQOVLIND pagingQueueOverflowIndication


A30808-X3247-M230-6-7619

141
CML:BSC BSC
Id:0900d805800d4401
System Responses:
- Operation Completed
NAME: name
NETWTYPE: networkType
T3122: waitIndication
ERRACT: errorAct
ENCALSUP: encalg1
encalg2
encalg3
encalg4
encalg5
encalg6
encalg7
encalg8
encalg9
encalg10
BSCTYP: bscType (read only parameter)
MAXNCELL: maxNCel
MSCV: mscVersion
OVLSTTHR: ovlStartThreshold
OVLENTHR: ovlEndThreshold
BSCOVLH: bscOvlHand
BTSOVLH: btsOvlHand
MSCOVLH: mscOvlHand
EISDCCHHO: enableInterSdcchHo
ENFORCHO: enforceHo
NTWCARD: networkCard
AMONTH: aintTchMonitorThresholds
ASMONTH: aintSs7MonitorThresholds
SPENLAW: speechEncodingLaw
PCMTYPE: pcmType
EFRSUPP: enhancedFullRateSupport
CICFM: cicFormat
EPOOL: enablePooling
MSCPOOL: mscPooling
HRSPEECH: halfRateSpeechSupported


142 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
HRDATA: halfRateDataSupported
SPEED145: speedSupported_14_5
ENHSCSD: enableHSCSD
ENFOIAHO: enableForcedIntraCellHo
HOSYNC: handoverSynchronization
ASUBISAT: sbsAsubInterfacelsSatellited
AISAT: sbsAInterfacelsSatellited
EPREHSCSD: enablePreemptionHSCSD
MAFIRACHO: maxForcedIntraCellHO
MADGRLV: maxDowngradeLevel
NOTFACCH: notificationOnFACCH
MNTBMASK: maintenanceBitMask
DLAPDOVL: dowlinkLapdOverload
MEDAFUST: measurementDataFileUploadStart
MEDAFUPE: measurementDataFileUploadPeri
MASCLOGFS: MaxScannerLogFileSize
IMSIFSIZ: imsiFileSize
CFS: ctrFileSize
ALRMSEVBTS: alarmSeverityBts
ALRMSEVBTSM: alarmSeverityBtsm
ALRMSEVCBCL: alarmSeverityCbcl
ALRMSEVLPDLM: alarmSeverityLpdlm
ALRMSEVLPDLR: alarmSeverityLpdlr
ALRMSEVLPDLS: alarmSeverityLpdls
ALRMSEVOMAL: alarmSeverityOmal
ALRMSEVPCMA: alarmSeverityPcma
ALRMSEVPCMB: alarmSeverityPcmb
ALRMSEVPCMS: alarmSeverityPcms
ALRMSEVTRAU: alarmSeverityTrau
ALRMSEVTRX: alarmSeverityTrx
ALRMSEVPCU: alarmSeverityPcu
ALRMSEVFRL: alarmSeverityFrl
ALRMSEVNSVC: alarmSeverityNsvc
ALRMSEVPTPPKF: alarmSeverityPtppkf
ALRMSEVPCMG: alarmSeverityPcmg
BSCT1: bscTimer1


A30808-X3247-M230-6-7619

143
CML:BSC BSC
Id:0900d805800d4401
BSCT3: bscTimer3
BSCT4: bscTimer4
BSCT7: bscTimer7
BSCT8: bscTimer8
BSCT10: bscTimer10
BSCT11WPS: bscTimer11WPS
BSCT11PUB: bscTimerPub-
lic
BSCT13: bscTimer13
BSCT17: bscTimer17
BSCT18: bscTimer18
BSCT19: bscTimer19
BSCT20: bscTimer20
BSCTQHOWPS: bscTimerQueueHoWPS
BSCTQHOPUB: bscTimerQueueHoPublic
BSCT3121 bscTimer3121
TCBCSI: timerForCBCServiceInterruption
TRACEMR: traceMeasureReport
TRACEMG: traceMeasureGranularity
TRFCT: trafficControlTimer
EPA: enablePairing:
CBCPH: CBCphase
TGUARDTCHSD: timerGuardTchsd
CITASUP: cellIdTimeAdvSupport
LCSNSSC: lcsNssCentric
LCSMONTH: lCSMonitorTresholds
SIMSCREL99: systemInfoMscRel99
TRFPS trafficPs
NCRESELFLAG ncReselectionFlag
CSCH3CSCH4SUP: codingScheme3CodingScheme4Support
ACCEPTGDEGR: acceptableGPRSDegradation
EUSDCHO: enableUmtsSdcchHo
ALRMSEVIPLI: alarmSeverityIpli
ESUP: edgeSupport
NECI newEstablishCauseIndication
ASCIONECHMDL asciOneChannelModel
CCHANTFACT: cellChangeNotificationActive


144 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
GET BSC ALARMSEV
SYSPACKSYSSUP: SIPSISupport
HDCFS: historyOnDroppedCallsFileSize
HDCFUPE: historyOnDroppedCallsFileUploadPeriod
EUSCNCRESEL enableUmtsSuffCovNcResel
MISTSTRSH: missingTSThreshold
NACCNTWCOR: nACCNetworkControlOrder
TYPOFAMC: typeOfAlarmModuleCard
TYPOFETH: typeOfEthernet
ROUIPADD0: routerIPAddress0
ROUIPADD1: routerIPAddress1
SUBNETMASK0: SubnetMask0
SUBNETMASK1: SubnetMask1
TRANSPM: transparentPerformanceMeasurement
MAXLAPDMN: maxlapdmNumber
DGRSTRGYBCNT: downgradeStrategyForBusyCounting
TDTMWIND: timerDTMWaitIndicator
EENHDTMSUP: enabledEnhancedDTMSupport
T3197: t3197
PAGCOORCLB: pagingCoordinationClassB
NAME: name
ALRMSEVBTS: alarmSeverityBts
ALRMSEVBTSM: alarmSeverityBtsm
ALRMSEVCBCL: alarmSeverityCbcl
ALRMSEVLPDLM: alarmSeverityLpdlm
ALRMSEVLPDLR: alarmSeverityLpdlr
ALRMSEVLPDLS: alarmSeverityLpdls
ALRMSEVOMAL: alarmSeverityOmal
ALRMSEVPCMA: alarmSeverityPcma
ALRMSEVPCMB: alarmSeverityPcmb
ALRMSEVPCMS: alarmSeverityPcms
ALRMSEVTRAU: alarmSeverityTrau
ALRMSEVTRX: alarmSeverityTrx
ALRMSEVPCU: alarmSeverityPcu
ALRMSEVFRL: alarmSeverityFrl


A30808-X3247-M230-6-7619

145
CML:BSC BSC
Id:0900d805800d4401
GET BSC BASICS
ALRMSEVNSVC: alarmSeverityNsvc
ALRMSEVPTPPKF: alarmSeverityPtppkf
ALRMSEVPCMG: alarmSeverityPcmg
ALRMSEVIPLI: alarmSeverityIpli
NAME: name
NETWTYPE: networkType
T3122: waitIndication
ERRACT: errorAct
ENCALSUP: encalg1
encalg2
encalg3
encalg4
encalg5
encalg6
encalg7
encalg8
encalg9
encalg10
BSCTYP: bscType (read only parameter)
MAXNCELL: maxNCel
MSCV: mscVersion
OVLSTTHR: ovlStartThreshold
OVLENTHR: ovlEndThreshold
NTWCARD: networkCard
AMONTH: aintTchMonitorThresholds
ASMONTH: aintSs7MonitorThresholds
SPENLAW: speechEncodingLaw
PCMTYPE: pcmType
CICFM: cicFormat
HOSYNC: handoverSynchronization
MAFIRACHO: maxForcedIntraCellHO
MADGRLV: maxDowngradeLevel
NOTFACCH: notificationOnFACCH
MNTBMASK: maintenanceBitMask


146 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
GET BSC CONTROL
GET BSC TIMER
TRACEMG: traceMeasureGranularity
TRFCT: trafficControlTimer
CBCPH: CBCphase
TGUARDTCHSD: timer-
GuardTchsd
LCSMONTH: lCSMonitorTresholds
ACCEPTGDEGR: acceptableGPRSDegradation
MISTSTRSH: missingTSThreshold
NACCNTWCOR: nACCNetworkControlOrder
TYPOFAMC: typeOfAlarmModuleCard
TYPOFETH: typeOfEthernet
ROUIPADD0: routerIPAddress0
ROUIPADD1: routerIPAddress1
SUBNETMASK0: SubnetMask0
SUBNETMASK1: SubnetMask1
TDTMWIND: timerDTMWaitIndicator
MAXLAPDMN: maxLapdmNumber
TCBCSI: timerforCBCServiceInterruption
NAME: name
MEDAFUST: measurementDataFileUploadStart
MEDAFUPE: measurementDataFileUploadPeri
MASCLOGFS: MaxScannerLogFileSize
IMSIFSIZ: imsiFileSize
CFS: ctrFileSize
HDCFS: historyOnDroppedCallsFileSize
HDCFUPE: historyOnDroppedCallsFileUploadPeriod
NAME: name
BSCT1: bscTimer1
BSCT3: bscTimer3
BSCT4: bscTimer4
BSCT7: bscTimer7


A30808-X3247-M230-6-7619

147
CML:BSC BSC
Id:0900d805800d4401
GET BSC FLAGS
BSCT8: bscTimer8
BSCT10: bscTimer10
BSCT11WPS: bscTimer11WPS
BSCT11PUB: bscTimer11Public
BSCT13: bscTimer13
BSCT17: bscTimer17
BSCT18: bscTimer18
BSCT19: bscTimer19
BSCT20: bscTimer20
BSCTQHOPUB: bscTimerQueueHoPublic
BSCT3121 bscTimer3121
BSCTQHOWPS: bscTimerQueueHoWPS
T3197: t3197
NAME: name
BSCOVLH: bscOvlHand
BTSOV
LH:
btsovlHand
MSCOV
LH:
mscOvlHand
EISDC-
CHHO:
enableInterSd-
cchHo
ENFOR-
CHO:
enforceHo
EFRSUPP: enhancedFull-
RateSupport
EPOOL: enablePooling
MSCPOOL: mscPooling
HRSPEECH: hal-
fRateSpeech-
Supported
HRDATA: halfRateData-
Supported
SPEED145: speedSupport
ed_14_5
ENHSCSD: enableHSCSD


148 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
- Operation Failed
Application Guidelines:
None.
GET BSC ALARMSEV
None.
ENFOIAHO: enableForced-
IntracellHo
ASUBISAT: asubInterfaceOnSatellited
AISAT: aInterfaceIs-
Satellited
EPREHSCSD: enablePreemptionHSCSD
DLAPDOVL: downlinkLapdOverload
TRACEMR: traceMeasureReport
EPA: enablePairing
CITASUP: cellIdTimeAdvSupport
LCSNSSC: lcsNssCentric
SIMSCREL99: systemInfoMscRel99
TRFPS: trafficPs
NCRESELFLAG: ncReselectionFlag
CSCH3CSCH4SUP
:
codingScheme3CodingScheme4Support
EUSDCHO: enableUmtsSdcchHo
ESUP: edgeSupport
NECI: newEstablishCauseIndication
ASCIONECHMDL: asciOneChannelindication
SYSPACKSYS-
SUP:
sysInfoPacketSysInfoSupport
EUSCNCRESEL: enableUmtssuffCovNcResel
CCHANTFACT: cellChangedNotificationActive
TRANSPM: transparentPerformanceMeasurements
EENHDTMSUP: enabledEnhancedDTMSupport
PAGCOORCLB: pagingCoordinationClassB
DGRSTRGYBCNT: downgradeStrategyForBusyCounting
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

149
CML:BSC BSC
Id:0900d805800d4401
GET BSC BASICS
None.
GET BSC CONTROL
None.
GET BSC TIMER
None.
Example of Command Execution:
Get BSC:NAME=BSC:0,REQATTL=NETWTYPE&T3122&ERRACT&ENCALSUP&
BSCTYP&MAXNCELL&MSCV&OVLSTTHR&OVLENTHR&BSCOVLH& BTS-
OVLH&MSCOVLH&EISDCCHHO&ENFORCHO&NTWCARD&AMONTH&
ASMONTH&SPENLAW&PCMTYPE&EFRSUPP&CICFM&EPOOL&MSCPOOL&
HRSPEECH&HRDATA&SPEED145&ENHSCSD&ENFOIAHO&HOSYNC&
ASUBENCAP&ASUBISAT&AISAT&EPREHSCSD&MAFIRACHO& MADGRLV&NOT-
FACCH&MNTBMASK&DLAPDOVL&MEDAFUST&MEDAFUPE& MAS-
CLOGFS&IMSIFSIZ&CFS&ALRMSEVBTS&ALRMSEVBTSM&
ALRMSEVCBCL&ALRMSEVLPDLM&ALRMSEVLPDLR&ALRMSEVLPDLS&
ALRMSEVOMAL&ALRMSEVPCMA&ALRMSEVPCMB&ALRMSEVPCMS&
ALRMSEVTRAU&ALRMSEVTRX&ALRMSEVPCU&ALRMSEVFRL&
ALRMSEVNSVC&ALRMSEVPTPPKF&ALRMSEVPCMG&BSCT1&BSCT3&
BSCT4&BSCT7&BSCT8&BSCT10&
BSCT11WPS&BSCT11PUB&BSCT13&BSCT17&BSCT18&BSCT19&BSCT20&BSCT
QHO-
PUB&BSCTQHOWPS&BSCT3121&TCBCSI&TRACEMR&TRACEMG&TRFCT&EPA
&CBCPH&TGUARDTCHSD&CITASUP&LCSNSSC&LCS-
MONTH&SIMSCREL99&TRFPS&NCRESELFLAG&CSCH3CSCH4SUP&ACCEPT-
GDEGR&EUSDCHO&
ALRMSEVIPLI&ESUP&NECI&ASCIONECHMDL&EHRACTAMR&CCHANT-
FACT&SYSPACKSYSSUP&HDCFS&HDCFUPE&EUSCNCRESEL&MIST-
STRSH&HOSYNC&NACCNTWCOR&TYPOFAMC&TYPOFETH&ROUIPADD0&ROUI
PADD1&SUBNETMASK0&SUBNETMASK1&TRANSPM&MAXLAPDMN&DGRSTR-
GYBCNT;
GET BSC ALARMSEV
Get BSC ALARMSEV:NAME=BSC:0;
GET BSC BASICS
Get BSC BASICS:NAME=BSC:0;
GET BSC CONTROL


150 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
Get BSC CONTROL:NAME=BSC:0;
GET BSC TIMER
Get BSC TIMER:NAME=BSC:0;
GET BSC FLAGS
Get BSC FLAGS:NAME=BSC:0;
GET BSC ALARMSEV
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC ALARMSEV
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the global parameters, previously entered through the
SET BSC command, or the default values if the SET BSC command was not submitted.
Long Names:
NAME Addres of the managed object
ALRMSEVBTS alarmSeverityBts
ALRMSEVBTSM alarmSeverityBtsm
ALRMSEVCBCL alarmSeverityCbcl
ALRMSEVLPDLM alarmSeverityLpdlm
ALRMSEVLPDLR alarmSeverityLpdlr
ALRMSEVLPDLS alarmSeverityLpdls
ALRMSEVOMAL alarmSeverityOmal
ALRMSEVPCMA alarmSeverityPcma
ALRMSEVPCMB alarmSeverityPcmb
ALRMSEVPCMS alarmSeverityPcms
ALRMSEVTRAU alarmSeverityTrau
ALRMSEVTRX alarmSeverityTrx
ALRMSEVPCU alarmSeverityPcu
ALRMSEVFRL alarmSeverityFrl
ALRMSEVNSVC alarmSeverityNsvc
ALRMSEVPTPPKF alarmSeverityPtppkf
ALRMSEVPCMG alarmSeverityPcmg
GET BSC ALARMSEV NAME=BSC:0..0;


A30808-X3247-M230-6-7619

151
CML:BSC BSC
Id:0900d805800d4401
ALRMSEVIPLI alarmSeverityIpli
System Responses:
See GET BSC
Application Guidelines:
See GET BSC
Example of Command Execution:
See GET BSC
GET BSC BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the global parameters, previously entered through the
SET BSC command, or the default values if the SET BSC command was not submitted.
Long Names:
NAME Addres of the managed object
NETWTYPE networkType
T3122 waitIndication
ERRACT errorAct
ENCALSUP encryptionAlgorSupport
MAXNCELL maxNCell
MSCV mscVersion
OVLSTTHR ovlStartThreshold
OVLENTHR ovlEndThreshold
NTWCARD networkCard
AMONTH aintTchMonitorThresholds
ASMONTH aintSs7MonitorThresholds
SPENLAW speechEncodingLaw
PCMTYPE pcmType
CICFM cicFormat
HOSYNC handoverSynchronization
MAFIRACHO maxForcedIntraCellHo
GET BSC BASICS NAME=BSC:0..0;


152 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
MADGRLV maxDowngradeLevel
NOTFACCH notificationOnFACCH
MNTBMASK maintenanceBitMask
TCBCSI timerForCBCServiceInterruption
TRACEMG traceMeasureGranularity
TRFCT trafficControlTimer
CBCPH CBCphase
TGUARDTCHSD timerGuardTchsd
LCSMONTH lCSMonitorTresholds
ACCEPTGDEGR acceptableGPRSDegradation
MISTSTRSH missingTSThreshold
TYPOFAMC typeOfAlarmModuleCard
TYPOFETH typeOfEthernet
ROUIPADD<n> routerIPAddress<n>
SUBNETMASK<n> subNetMask<n>
NACCNTWCOR nACCNetworkControlOrder
TDTMWIND timerDTMWaitIndicator
MAXLAPDMN maxlapdmNumber
PAGQOVLIND pagingQueueOverflowIndication
System Responses:
See GET BSC
Application Guidelines:
See GET BSC
Example of Command Execution:
See GET BSC
GET BSC CONTROL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC CONTROL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the global parameters, previously entered through the
SET BSC command, or the default values if the SET BSC command was not submitted.
GET BSC CONTROL NAME=BSC:0..0;


A30808-X3247-M230-6-7619

153
CML:BSC BSC
Id:0900d805800d4401
Long Names:
NAME Addres of the managed object
MEDAFUST measurementDataFileUploadStart
HDCFUPE historyOnDroppedCallsFileUploadPeriod
MEDAFUPE measurementDataFileUploadPeri
MASCLOGFS maxScannerLogFileSize
CFS ctrFileSize
IMSIFSIZ imsiFileSize
HDCFS historyDroppedCallFileSize
System Responses:
See GET BSC
Application Guidelines:
See GET BSC
Example of Command Execution:
See GET BSC
GET BSC FLAGS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC FLAGS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the global parameters, previously entered through the
SET BSC command, or the default values if the SET BSC command was not submitted.
Long Names:
NAME Addres of the managed object
BSCOVLH bscOvlHand
BTSOVLH btsOvlHand
MSCOVLH mscOvlHand
EISDCCHHO enableInterSdcchHo
ENFORCHO enforceHo
EFRSUPP enhanceFullRateSupport
EPOOL enablePooling
MSCPOOL mscPooling
GET BSC FLAGS NAME=BSC:0..0;


154 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
HRSPEECH halfRateSpeechSupported
HRDATA halfRateDataSupported
SPEED145 speedSupported_14_5
ENHSCSD enableHSCSD
ENFOIAHO enableForcedIntracellHo
ASUBISAT asubInterfaceOnSatellited
AISAT aInterfaceIsSatellited
EPREHSCSD enablePreemptionHSCSD
DLAPDOVL downlinkLapdOverload
TRACEMR traceMeasureReport
EPA enablePairing
CITASUP cellIdTimeAdvSupport
LCSNSSC lcsNssCentric
SIMSCREL99 systemInfoMscRel99
TRFPS trafficPs
NCRESELFLAG ncReselectionFlag
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
EUSDCHO enableUmtsSdcchHo
ESUP edgeSupport
NECI newEstablishCauseIndication
ASCIONECHMDL asciOneChannelModel
SYSPACKSYSSUP sysInfoPacketSysInfoSupport
EUSCNCRESEL enableUmtsSuffCovNcResel
CCHANTFACT cellChangeNotificationActive
TRANSPM transparentPerformanceMeasurements
EENHDTMSUP enabledEnhancedDTMSupport
PAGCOORCLB pagingCoordinationClassB
DGRSTRGYBCNT downgradeStrategyForBusyCounting
System Responses:
See GET BSC
Application Guidelines:
See GET BSC
Example of Command Execution:
See GET BSC
GET BSC TIMER
GET BSC TIMER NAME=BSC:0..0;


A30808-X3247-M230-6-7619

155
CML:BSC BSC
Id:0900d805800d4401
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC TIMER
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the global parameters, previously entered through the
SET BSC command, or the default values if the SET BSC command was not submitted.
Long Names:
NAME Addres of the managed object
BSCT1 bscTimer1
BSCT3 bscTimer3
BSCT4 bscTimer4
BSCT7 bscTimer7
BSCT8 bscTimer8
BSCT10 bscTimer10
BSCT11PUB bscTimer11Public
BSCT13 bscTimer13
BSCT17 bscTimer17
BSCT18 bscTimer18
BSCT19 bscTimer19
BSCT20 bscTimer20
BSCTQHOPUB bscTimerQueueHoPublic
BSCT3121 bscTimer3121
BSCT11WPS bscTimer11WPS
BSCTQHOWPS bscTimerQueueHoWPS
T3197 t3197
System Responses:
See GET BSC
Application Guidelines:
See GET BSC
Example of Command Execution:
See GET BSC
GET BSC STAT
GET BSC STAT NAME=BSC:0..0;


156 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GET BSC STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the alarm status (ALS) of the BSC object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get BSC STAT:NAME=BSC:0;
GETLOCKED BSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC GETLOCKED BSC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the list of BSC locked objects.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETLOCKED BSC NAME=BSC:0..0;
Get Locked Object List Response BSC:
name = BSC:0


A30808-X3247-M230-6-7619

157
CML:BSC BSC
Id:0900d805800d4401
- Operation Failed
None.
Application Guidelines:
The system response is organized to have up to 10 MEID of locked objects in a
message.
Example of Command Execution:
Getlocked BSC:NAME=BSC:0;
MEMDUMP BSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC MEMDUMP BSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command allows the operator to get ''on line" information about contents of memory
locations. Proper check will be executed to grant that the access to the specified
address is executable according the specified format without cause damage to the
system (not all addressable areas are in fact accessible in every format).
Long Names:
NAME Addres of the managed object
TYPPROC typeProcessor
PHYADDR physicalAddress
ACCTYP accessType
LEND lengthData
System Responses:
- Operation Completed
lockedObjectList
ObjPath
...
ObjPath
MEMDUMP BSC NAME=BSC:0..0 ,TYPPROC= ,PHYADDR= ,ACCTYP=
,LEND=;
Message: PROCESSOR MAINTENANCE--> LMT LOCAL
MON. JAN. 01 1990 00:16:12


158 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
*** RESPONSE ***
MEMORY DUMP DATA
name = BSC:0
Type Processor: MPCC_ACT
Physical Address: HD00000
Alarm state: H0
dumpData =
H00 H01 H02 H03 H04 H05 H06 H07 H08
H09 H0A H0B H0C H0D H0E H0F H10 H11
H12 H13 H14 H15 H16 H17 H18 H19 H1A
H1B H1C H1D H1E H1F H20 H21 H22 H23
or in case of WORD access the format must be:
Message: PROCESSOR MAINTENANCE --> LMT LOCAL
MON. JAN. 01 1990 00:16:12
*** RESPONSE ***
MEMORY DUMP DATA
name = BSC:0
Type Processor: MPCC_ACT
Physical Address: HD00000
Alarm state: H0
dumpData =
H0100 H0302 H0504 H0706 H0908 H0b0a H0d0c H0f0e
H1110 H1312 H1514 H1716 H1918 H1b1a H1d1c H1f1e
2120 2322
or in case of DWORD access the format must be:
Message: PROCESSOR MAINTENANCE --> LMT LOCAL
MON. JAN. 01 1990 00:16:12
*** RESPONSE ***
MEMORY DUMP DATA
name = BSC:0
Type Processor: MPCC_ACT
Physical Address: HD00000
Alarm state: H0
dumpData =


A30808-X3247-M230-6-7619

159
CML:BSC BSC
Id:0900d805800d4401
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Memdump BSC:NAME=BSC:0,TYPPROC=MPCC_ACT,PHYADDR=D00000,
ACCTYP=BYTE,LEND=36;
H03020100 H07060504 H0b0a0908 H0f0e0d0c
H13121110 H17161514 H1b1a1918 H1f1e1d1c
PROCESSOR OUT OF SERVICE
The command is not performed because issued against an out of
service processor.
INVALID HARDWARE REGION
The command is not performed because issued against an invalid
hardware region (i.e. hardware not implemented).
INAVLID HARDWARE ACCESS MODE
The command is not performed because issued against an invalid
hardware region but with the wrong access type.


160 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
SET BSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BSC SET BSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the global parameters for BSC.
Long Names:
NAME Addres of the managed object
NETWTYPE networkType
SET BSC NAME=BSC:0..0 [,NETWTYPE=] [,T3122=] [,ERRACT=]
[,ENCALSUP=] [,MAXNCELL=] [,MSCV=] [,OVLSTTHR=]
[,OVLENTHR=] [,BSCOVLH=] [,BTSOVLH=] [,MSCOVLH=]
[,EISDCCHHO=] [,ENFORCHO=] [,NTWCARD=]
[,AMONTH=] [,ASMONTH=] [,SPENLAW=] [,PCMTYPE=]
[,EFRSUPP=] [,CICFM=] [,EPOOL=] [,MSCPOOL=]
[,HRSPEECH=] [,SPEED145=] [,ENHSCSD=] [,ENFOI-
AHO=] [,HOSYNC=] [,ASUBISAT=] [,AISAT=] [,EPREH-
SCSD=] [,MAFIRACHO=] [,MADGRLV=] [,NOTFACCH=]
[,MNTBMASK=] [,DLAPDOVL=] [,MEDAFUST=] [,HDC-
FUPE=] [,MEDAFUPE=] [,MASCLOGFS=] [,CFS=] [,IMSIF-
SIZ=] [,HDCFS=] [,ALRMSEVBTS=] [,ALRMSEVBTSM=]
[,ALRMSEVCBCL=] [,ALRMSEVLPDLM=] [,ALRMSEVLP-
DLR=] [,ALRMSEVLPDLS=] [,ALRMSEVOMAL=] [,ALRM-
SEVPCMA=] [,ALRMSEVPCMB=] [,ALRMSEVPCMS=]
[,ALRMSEVTRAU=] [,ALRMSEVTRX=] [,ALRMSEVPCU=]
[,ALRMSEVFRL=] [,ALRMSEVNSVC=] [,ALRMSEVPTP-
PKF=] [,ALRMSEVPCMG=] [,BSCT1=] [,BSCT3=]
[,BSCT4=] [,BSCT7=] [,BSCT8=] [,BSCT10=]
[,BSCT11PUB=] [,BSCT13=] [,BSCT17=] [,BSCT18=]
[,BSCT19=] [,BSCT20=] [,BSCTQHOPUB=] [,BSCT3121=]
[,TCBCSI=] [,TRACEMR=] [,TRACEMG=] [,TRFCT=]
[,EPA=] [,CBCPH=] [,TGUARDTCHSD=] [,CITASUP=]
[,LCSNSSC=] [,LCSMONTH=] [,SIMSCREL99=] [,TRFPS=]
[,NCRESELFLAG=] [,CSCH3CSCH4SUP=] [,ACCEPT-
GDEGR=] [,EUSDCHO=] [,ALRMSEVIPLI=] [,ESUP=]
[,NECI=] [,ASCIONECHMDL=] [,SYSPACKSYSSUP=]
[,EUSCNCRESEL=] [,MISTSTRSH=] [,CCHANTFACT=]
[,BSCT11WPS=] [,BSCTQHOWPS=] [,TYPOFAMC=]
[,TYPOFETH=] [,ROUIPADD<n>=] [,SUBNETMASK<n>=]
[,NACCNTWCOR=] [,TRANSPM=] [,TDTMWIND=] [,MAX-
LAPDMN=] [,EENHDTMSUP=] [,T3197=] [,PAGCOOR-
CLB=] [,DGRSTRGYBCNT=] [,PAGQOVLIND=];


A30808-X3247-M230-6-7619

161
CML:BSC BSC
Id:0900d805800d4401
T3122 waitIndication
ERRACT errorAct
ENCALSUP encryptionAlgorSupport
MAXNCELL maxNCell
MSCV mscVersion
OVLSTTHR ovlStartThreshold
OVLENTHR ovlEndThreshold
BSCOVLH bscOvlHand
BTSOVLH btsOvlHand
MSCOVLH mscOvlHand
EISDCCHHO enableInterSdcchHo
ENFORCHO enforceHo
NTWCARD networkCard
AMONTH aintTchMonitorThresholds
ASMONTH aintSs7MonitorThresholds
SPENLAW speechEncodingLaw
PCMTYPE pcmType
EFRSUPP enhanceFullRateSupport
CICFM cicFormat
EPOOL enablePooling
MSCPOOL mscPooling
HRSPEECH halfRateSpeechSupported
SPEED145 speedSupported_14_5
ENHSCSD enableHSCSD
ENFOIAHO enableForcedIntracellHo
HOSYNC handoverSynchronization
ASUBISAT asubInterfaceOnSatellited
AISAT aInterfaceIsSatellited
EPREHSCSD enablePreemptionHSCSD
MAFIRACHO maxForcedIntraCellHo
MADGRLV maxDowngradeLevel
NOTFACCH notificationOnFACCH
MNTBMASK maintenanceBitMask
DLAPDOVL downlinkLapdOverload
MEDAFUST measurementDataFileUploadStart
HDCFUPE historyOnDroppedCallsFileUploadPeriod
MEDAFUPE measurementDataFileUploadPeri
MASCLOGFS maxScannerLogFileSize
CFS ctrFileSize


162 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
IMSIFSIZ imsiFileSize
HDCFS historyDroppedCallFileSize
ALRMSEVBTS alarmSeverityBts
ALRMSEVBTSM alarmSeverityBtsm
ALRMSEVCBCL alarmSeverityCbcl
ALRMSEVLPDLM alarmSeverityLpdlm
ALRMSEVLPDLR alarmSeverityLpdlr
ALRMSEVLPDLS alarmSeverityLpdls
ALRMSEVOMAL alarmSeverityOmal
ALRMSEVPCMA alarmSeverityPcma
ALRMSEVPCMB alarmSeverityPcmb
ALRMSEVPCMS alarmSeverityPcms
ALRMSEVTRAU alarmSeverityTrau
ALRMSEVTRX alarmSeverityTrx
ALRMSEVPCU alarmSeverityPcu
ALRMSEVFRL alarmSeverityFrl
ALRMSEVNSVC alarmSeverityNsvc
ALRMSEVPTPPKF alarmSeverityPtppkf
ALRMSEVPCMG alarmSeverityPcmg
BSCT1 bscTimer1
BSCT3 bscTimer3
BSCT4 bscTimer4
BSCT7 bscTimer7
BSCT8 bscTimer8
BSCT10 bscTimer10
BSCT11PUB bscTimer11Public
BSCT13 bscTimer13
BSCT17 bscTimer17
BSCT18 bscTimer18
BSCT19 bscTimer19
BSCT20 bscTimer20
BSCTQHOPUB bscTimerQueueHoPublic
BSCT3121 bscTimer3121
TCBCSI timerForCBCServiceInterruption
TRACEMR traceMeasureReport
TRACEMG traceMeasureGranularity
TRFCT trafficControlTimer
EPA enablePairing
CBCPH CBCphase


A30808-X3247-M230-6-7619

163
CML:BSC BSC
Id:0900d805800d4401
TGUARDTCHSD timerGuardTchsd
CITASUP cellIdTimeAdvSupport
LCSNSSC lcsNssCentric
LCSMONTH lCSMonitorTresholds
SIMSCREL99 systemInfoMscRel99
TRFPS trafficPs
NCRESELFLAG ncReselectionFlag
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
ACCEPTGDEGR acceptableGPRSDegradation
EUSDCHO enableUmtsSdcchHo
ALRMSEVIPLI alarmSeverityIpli
ESUP edgeSupport
NECI newEstablishCauseIndication
ASCIONECHMDL asciOneChannelModel
SYSPACKSYSSUP sysInfoPacketSysInfoSupport
EUSCNCRESEL enableUmtsSuffCovNcResel
MISTSTRSH missingTSThreshold
CCHANTFACT cellChangeNotificationActive
BSCT11WPS bscTimer11WPS
BSCTQHOWPS bscTimerQueueHoWPS
TYPOFAMC typeOfAlarmModuleCard
TYPOFETH typeOfEthernet
ROUIPADD<n> routerIPAddress<n>
SUBNETMASK<n> subNetMask<n>
NACCNTWCOR nACCNetworkControlOrder
TRANSPM transparentPerformanceMeasurements
TDTMWIND timerDTMWaitIndicator
MAXLAPDMN maxlapdmNumber
EENHDTMSUP enabledEnhancedDTMSupport
T3197 t3197
PAGCOORCLB pagingCoordinationClassB
DGRSTRGYBCNT downgradeStrategyForBusyCounting
PAGQOVLIND pagingQueueOverflowIndication
System Responses:
- Operation Completed
Successful
- Operation Failed


164 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
NACK CAUSES:
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 5, n. 8, n. 11, n. 14, n.
15, n. 16, n. 18, n. 19, n. 20, n. 21, n. 29, n. 30, n.31.
If BTS objects are equipped and have DGRSTRGY attribute set to
HSCSD_FIRST_DOWNGRADE or
DOWNGRADE_HSCSD_ONLY, the attribute MADGRLV cannot
be set to 0.
The attribute HOSYNC can be set to SYNC only if all cells belong-
ing to the same site must have the same BURNOFFS value.
The NETWTYPE must be compatible with the frequencies belong
to CBTSs equipped.
The NETWTYPE isn't compatible with SUBBAND of CFHSY's.
If the NTWCARD is set to NTWSNAP_STLP the TYPOFAMC
attribute cannot be set to DK40.
If the NTWCARD is set to NTWSNAP the TYPOFAMC attribute
cannot be set to CPEX.
The value of ROUIPADDx and SUBNETMASKx must be valid IP
address.
The related attributes ROUIPADDx and SUBNETMASKx must be
set both to NULL or both to a value different from NULL.
Each items of the ENCALSUP parameter must be set to a value
different from the another one.
SUBORDINATE_EQUIPPED
Make reference to Application Guidelines n. 4, n. 6, n. 9, n. 10.
The value of TYPOFAMC cannot be set to a value different from
ESAM if any GBIPLNK is already equipped.
UNSUCCESSFUL_INVALID_STATUS
Make reference to Application Guidelines n. 7, n. 22, n. 27.
In order to set the TYPOFETH all PCU over IP must be locked.
In order to set TYPOFAMC from DK40 to ES, the DK40 object
must be locked.
In order to set TYPOFAMC from ES to DK40, the CPEX and ES
objects must be locked.
In order to set TYPOFAMC from ES to CPEX, the ES objects must
be locked.
UNSUCCESSFUL_IN_TEST
The attribute NTWCARD can not be modified if a
diagnostic test is in progress on one of the NTW copies.
UNSUCCESSFUL_VAR_OUT_OF_RANGE


A30808-X3247-M230-6-7619

165
CML:BSC BSC
Id:0900d805800d4401
Application Guidelines:
1. The attributes NETWTYPE, NTWCARD and PCMTYPE can be set only if there are
no subordinated object instances.
2. The BSC object is automatically created with default values when the BSS is
powered up.
3. The BSC object cannot be deleted; the parameter values can only be changed.
4. The networktype can be set only if there are no bts equipped.
5. OVLSTTHR must be greater than OVLENTHR or equal.
6. The attribute NTWCARD can be set only if there are no LICD and LICDS equipped.
For the attributes AMONTH and ASMONTH the following relation
must be satisfied:
minorVal < majorVal < criticalVal.
TRACE_OBJECT_UNLOCKED
The imsiFileSize attribute can set only when the TRACE object is
not equipped or, if equipped, in LOCKED status.
INVALID_COMMAND
The NTWCARD cannot be changed from NTWSNAP to
NTWSNAP_STLP or vice versa.
UNSUCCESSFUL_CSCH3CSCH4_SUPPORTED
The CSCH3CSCH4SUP attribute cannot be set at FALSE if at
least one PTPPKF has CSCH3CSCH4SUP set at TRUE.
UNSUCCESSFUL_WRONG_NTWTYPE
The attribute ESUP can be set at TRUE only if the attribute
NTWCARD is set at NTWSNAP.
The attribute NTWCARD can not be set at a value different from
NTWSNAP if attribute ESUP is set at TRUE.
UNSUCCESSFUL_EDGE_TRX_PRESENT
The attribute ESUP can be set at FALSE only if there are no
subordinated TRX objects with TRXMD set at EDGE.
INCOMP_NESWLOAD_VS_MESSAGE
The attribute EUSDCHO must be set at FALSE if the Software
Version running on the subordinate BTSM object belongs to
BR6.0 release (see EXPSWV parameter description).
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The NTWCARD attribute can be changed from NTWSNAP to
NTWSN16 only if no PPXT and PCUTD are equipped.
UNSUCCESSFUL_CODING_SCHEME_NOT_SUPPORTED
Bit 25 of MNTBMASK cannot be set to 1 because some PTPPKF
has been configured wih INICSCH attribute set to a value greater
than CS2.


166 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
7. The attribute NTWCARD can be modified only if both the NTW copies are in locked
state.
8. Regarding the attributes AMONTH and ASMONTH, the flags minorena, majorena,
criticalena and the relative thresholds attributes, note that:
if the flags are set at ENABLE the threshold values cannot be skipped;
if the flags are set at DISABLE the threshold values must be skipped;
if the flags are skipped also the threshold values must be skipped.
9. The attribute SPENLAW can be set only if there are no instances of TRAU objects
equipped on BSC.
10. The attribute PCMTYPE can be set only if there are no instances of LICD and LICDS
equipped.
11. The attribute PCMTYPE can only be set at PCM24 if the attribute NETWTYPE has
a value of GSMPCS, GSM850PCS or GSM850DCS.
12. When the forced handover is enabled (ENFORCHO attribute) the following
attributes are relevant:
13. The timer TIMERFHO (see ADJC object) is running on the adjacent cell serving the
Directed Retry signalling procedure: that is timer is defined in ADJC A-B for Directed
Retry procedure from A to B. This timer also prevents the back handovers for power
budget to the origin cell A, until it expires.
14. The value NOTSTRUCT for the CICFM attribute is allowed only if the PCMTYPE is
set to PCM24.
15. The attribute ENHSCSD can be set at TRUE only if EPOOL attribute is set at TRUE.
16. The attribute ENHSCSD can be set at FALSE only if HSCSD service is not activated
at BTS side , for each BTS (BTSHSCSD attribute of each BTS is set at FALSE).
17. The attribute EPOOL can only be used to change the pooling state: i.e. EPOOL can
be set at TRUE only when its current value is FALSE and it can be reset to FALSE
only when its current value is TRUE. In particular it is not possible to use this
attribute to change the pool type of all the equipped TSLAs.
18. The pooling can be disabled only if every equipped TSLA has single-slot pool_type.
19. In order to enable the Half Rate service the HRSPEECH attribute must be set at
TRUE.
20. The attribute SPEED145 cannot be set at FALSE if some subordinate BTS has the
attribute BTSSUPP145 set at TRUE.
21. The attributes AISAT and ASUBISAT can be modified only if both the NTW copies
are in locked state.
22. The following relationships must be satisfied between the value of the BSC7 timer
and the values of the THORQST timer (HAND object) and the MSC-internal
T_HO_REQ_REJ timer:
T_HO_REQ_REJ (MSC) < BSCT7 < THORQST (HAND).
23. To optimize the time consumption of the BSSMAP reset procedure make sure that:
fHORxLevMinOffset ADJC:FHORLMO
timerFHO ADJC:TIMERFHO


A30808-X3247-M230-6-7619

167
CML:BSC BSC
Id:0900d805800d4401
BSCT16 at MSC side > BSCT13 at BSC side, and
BSCT4 at BSC side > BSCT2 at MSC side.
To avoid inconsistencies of the trunk status at MSC and BSC side please make sure
that T16 at MSC side does not expire before the blocking procedure at the A-inter-
face (initiated by BSC) has been completed. In case of BSCT16 expiry MSC repeats
the reset message and all information about previously blocked circuits at the BSC
is lost at msc side. The time consumption of the blocking procedure depends on the
amount of PCM lines connecting BSC and MSC.
Recommended value for BSCT16: 35s.
24. For supervision of receipt of assignment complete or handover complete the SBS
only uses timer BSCT10 resp. BSCT8 (GSM Rec. 08.08). Within GSM Rec. 04.08
timer T3107 is specified for supervision of receipt of handover complete resp.
assignment complete. In addition two timers with the same task are specified for
BSSMAP, namely BSCT8 and BSCT10. To easier the handling of these timers only
two of them are used within SBS. There is no lack in supervision of above named
messages due to this implementation, neither for internal nor for external handover
procedures.
25. If EPRE parameter (see BTS object) is set at TRUE value, the timer BSCT7 must
be set at a value between 6 and 254.
26. The attributes TRACEMG and TRACEMR can be modified only if the TRACE and
the CTRCO objects are in "Locked" state.
27. All AMR TRAUs and all S2 and S3 TRAUs must be in LOCKED state in order to set
EPOOL at FALSE.
28. The default value of the attribute NTWCARD is NTWSNAP.
29. The attribute NCRESELFLAG cannot be set to DISABLE if the attribute TRFPS is
TRUE;
30. The attribute TRFPS cannot be set to TRUE if the attribute NCRESELFLAG is set
to DISABLE.
31. The MSCVER attribute can be set to PHASE1, PHASE2 or PHASE2CC only if no
BTSTD is equipped.
32. Regarding the MNTBMASK parameter, the following considerations can be done:
every command "SET BSC:MNTBMASK=BITx" resets the maintenance bit
mask to its default value und just changes that bit which is included in the
command. In other words, if BITy was set before, the command SET BSC:MNT-
BMASK=BITx; resets BITy to '0' and sets BITx to '1'. This means that, if some of
the bits are already set, and another one is to be set in addition, it is required to
re-enter the command with ALL required bits set;
all bits can be reset to their original values using the setting MNTB-
MASK=<NULL> or MNTBMASK=<DEFAULT>;
to set several bits at the same time, they must be linked with a 'pipe' (Example:
MNTBMASK=BIT8|BIT9).
Example of Command Execution:
Set BSC:NAME=BSC:0,NETWTYPE=GSMDCS,T3122=10, ERRACT=CRITICAL-
MAJOR-MAJOR-MINOR-WARNING,ENCALSUP=NOENCR&GSMV1,MAXN-
CELL=1,MSCV=PHASE1,OVLSTTHR=7000,


168 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4401
BSC
OVLENTHR=7000,BSCOVLH=FALSE,BTSOVLH=FALSE,MSCOVLH=FALSE, EISD-
CCHHO=ENABLE,ENFORCHO=ENABLE,NTW-
CARD=NTWSN16,AMONTH=ENABLE-35-ENABLE-65-ENABLE-
95,ASMONTH=ENABLE35ENABLE65ENABLE95,SPENLAW=A_LAW,PCM-
TYPE=PCM30,EFRSUPP=FALSE,CICFM=GSM,
EPOOL=TRUE,MSCPOOL=TRUE,HRSPEECH=TRUE,SPEED145=TRUE,ENH-
SCSD=TRUE,ENFOIAHO=TRUE, HOSYNC=NONSYNC,ASUBI-
SAT=FALSE,AISAT=FALSE,
MAFIRACHO=3,MADGRLV=2,NOTFACCH=ALWAYS,DLAP-
DOVL=TRUE,MEDAFUST=1-30, MEDAFUPE=UPPE_0H,MASCLOGFS=4, IMSIF-
SIZ=15, CFS=3,ALRMSEVBTS=MAJOR,ALRMSEVTRX=CRITICAL,BSCT1=SEC5-
10,BSCT3=SEC5-30,BSCT4=HALFSEC-18,BSCT7=SEC5-31,BSCT8=HALFSEC-
25,BSCT10=SEC5-30,BSCT11WPS=HLFSEC-38, BSCT11PUB=HLFSEC-
38,BSCT13=HALFSEC-50,BSCT17=SEC5-70,BSCT18=SEC5-40,BSCT19=SEC5-
60,BSCT20=SEC5-12,BSCTQHOPUB=SEC5-80, BSCTQHOWPS=SEC5-80,
BSCT3121=HLFSEC10,TCB-
SCI=100,TRACEMR=TRUE,TRACEMG=5,TRFCT=30,EPA=TRUE,CBCPH=PH1_CB
C,TGUARDTCHSD=SEC0,CITASUP=TRUE,LCSNSSC=TRUE,LCSMONTH=1-1-
1,SIMSCREL99=FALSE, TRFPS= FALSE, NCRESELFLAG=DISABLE,
CSCH3CSCH4SUP=FALSE, ACCEPGDEGR=PER20, EUSDCHO=FALSE,ALRM-
SEVIPLI=MAJOR, ESUP=TRUE,NECI=TRUE, ASCIONECHMDL=TRUE, EHRAC-
TAMR=TRUE,CCHANFACT=FALSE, SYSPACKSYSSUP=FALSE, HDCFS=1,
HDCFUPE=0, EUSCNCRESEL=FALSE, MISTSTRSH=3, NACCNTWCOR=nc0,
TRANSPM=FALSE,MAXLAPDMN=5,DGRSTRGYBCNT=DISABLED,TDTM-
WIND=5,T3197=4,EENHDTMSUP=DISABLED,PAGCOORCLB=DIS-
ABLED,PAGQOVLIND=0;
The following is an example of the command necessary to configure a network having
an MSC not supporting new A-Interface IES (Current Channel, Speech Version used
and chosen), as in Latin America.
Set BSC:NAME=BSC:0, NETWTYPE=GSMPCS,...,
MAXNCELL=maxNCell,MSCV=PHASE2;
while the following is an example of the set of commands necessary to configure a
network having an MSC supporting new A-Interface IES (as in USA):
Set BSC:NAME=BSC:0,NETWTYPE=GSMPCS,...,MAXNCELL=maxNCell,
MSCV=PHASE2CCEFR;


A30808-X3247-M230-6-7619

169
CML:BSC BSCE
Id:0900d805800d5341
BSCE
The BSCE object represents the BSC equipment.
GET BSCE
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE GET BSCE
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
of the BSCE object related to:
alarm severity of the associated BSCE hardware objects;
remote inventory (SALUNAME and EQUPOS).
Long Names:
NAME Addres of the managed object
ALRMSEVDISK alarmSeverityDisk
ALRMSEVDK40 alarmSeverityDk40
ALRMSEVEPWR alarmSeverityEpwr
ALRMSEVIXLT alarmSeverityIxlt
ALRMSEVLICD alarmSeverityLicd
ALRMSEVLICDS alarmSeverityLicds
ALRMSEVMEMT alarmSeverityMemt
ALRMSEVMPCC alarmSeverityMpcc
ALRMSEVNTW alarmSeverityNtw
ALRMSEVPWRD alarmSeverityPwrd
ALRMSEVSYNC alarmSeveritySync
ALRMSEVSYNE alarmSeveritySyne
ALRMSEVTDPC alarmSeverityTdpc
ALRMSEVX25A alarmSeverityX25a
GET BSCE NAME=BSCE:0..0 [,REQATTL= ALRMSEVDISK
,ALRMSEVDK40 ,ALRMSEVEPWR ,ALRMSEVIXLT
,ALRMSEVLICD ,ALRMSEVLICDS ,ALRMSEVMEMT
,ALRMSEVMPCC ,ALRMSEVNTW ,ALRMSEVPWRD
,ALRMSEVSYNC ,ALRMSEVSYNE ,ALRMSEVTDPC
,ALRMSEVX25A ,ALRMSEVX25D ,ALRMSEVPPXL
,ALRMSEVPPXU,ALRMSEVCPEX ,ALRMSEVFAN ,ALRM-
SEVES ,SALUNAME ,EQUPOS ,EAUTOREC];


170 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5341
BSCE
ALRMSEVX25D alarmSeverityX25d
ALRMSEVPPXL alarmSeverityPpxl
ALRMSEVPPXU alarmSeverityPpxu
ALRMSEVCPEX alarmSeverityCPEX
ALRMSEVFAN alarmSeverityFAN
ALRMSEVES alarmSeverityES
SALUNAME salesUniqueName
EQUPOS equipmentPosition
EAUTOREC enableAutoRecovery
System Responses:
- Operation Completed
NAME name
ALRMSEVDISK: alarmSeverityDisk
ALRMSEVDK40: alarmSeverityDk40
ALRMSEVEPWR: alarmSeverityEpwr
ALRMSEVES: alarmSeverityES
ALRMSEVIXLT: alarmSeverityIxlt
ALRMSEVLICD: alarmSeverityLicd
ALRMSEVLICDS: alarmSeverityLicds
ALRMSEVMEMT: alarmSeverityMemt
ALRMSEVMPCC: alarmSeverityMpcc
ALRMSEVNTW: alarmSeverityNtw
ALRMSEVPWRD: alarmSeverityPwrd
ALRMSEVSYNC: alarmSeveritySync
ALRMSEVSYNE: alarmSeveritySyne
ALRMSEVTDPC: alarmSeverityTdpc
ALRMSEVX25A: alarmSeverityX25a
ALRMSEVX25D: alarmSeverityX25d
ALRMSEVPPXL: alarmSeverityPpxl
ALRMSEVPPXU: alarmSeverityPpxu
ALRMSEVCPEX: alarmSeverityCPEX
ALRMSEVFAN: alarmSeverityFAN
SALUNAME: salesUniqueName
EQUPOS: equipmentPosition
EAUTOREC: enableAutoRecovery


A30808-X3247-M230-6-7619

171
CML:BSC BSCE
Id:0900d805800d5341
GET BSCE ALARMSEV
GET BSCE REMINV
- Operation Failed
NACK CAUSES:
NAME name
ALRMSEVDISK: alarmSeverityDisk
ALRMSEVDK40: alarmSeverityDk40
ALRMSEVEPWR: alarmSeverityEpwr
ALRMSEVIXLT: alarmSeverityIxlt
ALRMSEVLICD: alarmSeverityLicd
ALRMSEVLICDS: alarmSeverityLicds
ALRMSEVMEMT: alarmSeverityMemt
ALRMSEVMPCC: alarmSeverityMpcc
ALRMSEVNTW: alarmSeverityNtw
ALRMSEVPWRD: alarmSeverityPwrd
ALRMSEVSYNC: alarmSeveritySync
ALRMSEVSYNE: alarmSeveritySyne
ALRMSEVTDPC: alarmSeverityTdpc
ALRMSEVX25A: alarmSeverityX25a
ALRMSEVX25D: alarmSeverityX25d
ALRMSEVPPXL: alarmSeverityPpxl
ALRMSEVPPXU: alarmSeverityPpxu
ALRMSEVCPEX: alarmSeverityCPEX
ALRMSEVFAN: alarmSeverityFAN
SALUNAME: salesUniqueName
EQUPOS: equipmentPosition
NAME name
SALUNAME salesUniqueName
EQUPOS equipmentPosition
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already created.
UNSUCCESSFUL_FILE_SYSTEM_ERROR
A file system error occurs during the DK40 access.


172 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5341
BSCE
Application Guidelines:
None.
GET BSCE ALARMSEV
None.
GET BSCE REMINV
None.
Example of Command Execution:
Get BSCE:NAME=BSCE:0,REQATTL=ALRMSEVDISK&ALRMSEVDK40&
ALRMSEVEPWR&ALRMSEVES&ALRMSEVIXLT&ALRMSEVLICD&ALRMSEV-
LICDS&ALRMSEVMEMT&ALRMSEVMPCC&ALRMSEVNTW&ALRMSEVP-
WRD&ALRMSEVSYNC&ALRMSEVSYNE&ALRMSEVTDPC& ALRMSEVX25A&
ALRMSEVX25D& ALRMSEVPPXL&ALRMSEVPPXU&ALRMSEVCPEX&ALRMSEV-
FAN&SALUNAME&EQUPOS&EAUTOREC;
GET BSCE ALARMSEV
Get BSCE ALARMSEV:NAME=BSCE:0;
GET BSCE REMINV
Get BSCE REMINV:NAME=BSCE:0;
GET BSCE ALARMSEV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE GET BSCE ALARMSEV
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
of the BSCE object related to:
alarm severity of the associated BSCE hardware objects;
remote inventory (SALUNAME and EQUPOS).
FILE_CORRUPTED
The file on DK40 is corrupted: delete it.
GET BSCE ALARMSEV NAME=BSCE:0..0;


A30808-X3247-M230-6-7619

173
CML:BSC BSCE
Id:0900d805800d5341
Long Names:
NAME Addres of the managed object
ALRMSEVDISK alarmSeverityDisk
ALRMSEVDK40 alarmSeverityDk40
ALRMSEVEPWR alarmSeverityEpwr
ALRMSEVIXLT alarmSeverityIxlt
ALRMSEVLICD alarmSeverityLicd
ALRMSEVLICDS alarmSeverityLicds
ALRMSEVMEMT alarmSeverityMemt
ALRMSEVMPCC alarmSeverityMpcc
ALRMSEVNTW alarmSeverityNtw
ALRMSEVPWRD alarmSeverityPwrd
ALRMSEVSYNC alarmSeveritySync
ALRMSEVSYNE alarmSeveritySyne
ALRMSEVTDPC alarmSeverityTdpc
ALRMSEVX25A alarmSeverityX25a
ALRMSEVX25D alarmSeverityX25d
ALRMSEVPPXL alarmSeverityPpxl
ALRMSEVPPXU alarmSeverityPpxu
ALRMSEVCPEX alarmSeverityCPEX
ALRMSEVFAN alarmSeverityFAN
ALRMSEVES alarmSeverityES
System Responses:
See GET BSCE
Application Guidelines:
See GET BSCE
Example of Command Execution:
See GET BSCE
GET BSCE BASICS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE GET BSCE BASICS
Applicability:
Phase 2.
Visibility level: 0.
GET BSCE BASICS NAME=BSCE:0..0;


174 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5341
BSCE
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
of the BSCE object related to:
alarm severity of the associated BSCE hardware objects;
remote inventory (SALUNAME and EQUPOS).
Long Names:
NAME Addres of the managed object
EAUTOREC enableAutoRecovery
System Responses:
See GET BSCE
Application Guidelines:
See GET BSCE
Example of Command Execution:
See GET BSCE
GET BSCE REMINV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE GET BSCE REMINV
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
of the BSCE object related to:
alarm severity of the associated BSCE hardware objects;
remote inventory (SALUNAME and EQUPOS).
Long Names:
NAME Addres of the managed object
SALUNAME salesUniqueName
EQUPOS equipmentPosition
System Responses:
See GET BSCE
Application Guidelines:
See GET BSCE
GET BSCE REMINV NAME=BSCE:0..0;


A30808-X3247-M230-6-7619

175
CML:BSC BSCE
Id:0900d805800d5341
Example of Command Execution:
See GET BSCE
GETACTIVEALARMS BSCE
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE GETACTIVEALARMS BSCE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the list of the active alarms, selected by means of the
event type parameters.
Long Names:
NAME Addres of the managed object
EVTYP eventType
System Responses:
- Operation Completed
The output of the command can be composed by one or more packages with a
maximum number of three mnemonics of objects enqueued in the specified alarm event
list; at the end a message is displayed notifying the end of the alarm event list.
- Operation Failed
None.
Application Guidelines:
1. Hardware objects which are in disabled-not-inizialized state (e.g. during cross copy)
are not reported in the active alarm list.
2. The active alarm list of the TRAU retrieved from LMT-BSC (GETACTIVEALARMS
TRAUE) and/or by RC will contain only the equipment managed objects (BSMS,
TPWR, TRAC) whereas when it is retrieved directly from LMT-TRAU it will contain
also the functional managed objects (PCMS, PCMT, TRANSCODER).
Example of Command Execution:
Getactivealarms BSCE:NAME=BSCE:0,EVTYP=COMMUNICATION_
FAILURE_EVENT;
GETACTIVEALARMS
BSCE
NAME=BSCE:0..0 [,EVTYP=];


176 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5341
BSCE
PERFTEST BSCE
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PERFTEST BSCE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to start an asynchronous test in the BSC system; different
categories of test can be addressed.
The operator can request to perform several diagnostics on different hardware units and
the diagnostic must be able to manage all the requests. The maximum number of
diagnostics that can run in parallel are 8, moreover they can be executed only if
compatible with the ones in progress.
If the requested diagnostic is incompatible or 8 different diagnostics are already running,
a queuing procedure is implemented and it will be executed when possible. Otherwise
it is activated at once. The incompatible diagnosis are indicated in the following table.
Long Names:
NAME Addres of the managed object
PERFTEST BSCE NAME=BSCE:0..0 ,MORT=;
Object Incompatible with
MPCC MPCC TDPC MEMT
DK40 DK40
TDPC TDPC MPCC MEMT
MEMT MEMT MPCC TDPC
NTW NTW PPXU PPXL
IXLT IXLT
LICD LICD LICDS
LICDS LICDS LICD
PWRD PWRD EPWR
EPWR EPWR PWRD
DISK DISK MPCC
PPXU PPXU PPXL NTW
PPXL PPXL PPXU NTW
CPEX CPEX ES
ES ES CPEX


A30808-X3247-M230-6-7619

177
CML:BSC BSCE
Id:0900d805800d5341
MORT MOT
System Responses:
- Operation Completed
PERFTEST BSCE:NAME=BSCE:0, MORT=PPXU:1
testObject=BSCETEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = BSCETEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase. phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)


178 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5341
BSCE
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive; for the EPWR and PWRD objects the administra-
tive state can be "Unlocked" (diagnostic not intrusive).
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
3. If a test request for a PPXX (PPXL or PPXU) object fails because an other load is in
progress, the object is not reloaded automatically; the command must be repeated
in order to reload the card.
Example of Command Execution:
Perftest BSCE:NAME=BSCE:0,MORT=PPXU:0;
SET BSCE
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE SET BSCE
MOTS_NOT_LOCKED
The selected object is not in "Locked" administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
SET BSCE NAME=BSCE:0..0 [,ALRMSEVDISK=] [,ALRMSEVDK40=]
[,ALRMSEVEPWR=] [,ALRMSEVIXLT=] [,ALRMSEVLICD=]
[,ALRMSEVLICDS=] [,ALRMSEVMEMT=] [,ALRM-
SEVMPCC=] [,ALRMSEVNTW=] [,ALRMSEVPWRD=]
[,ALRMSEVSYNC=] [,ALRMSEVSYNE=] [,ALRMSEVT-
DPC=] [,ALRMSEVX25A=] [,ALRMSEVX25D=] [,ALRM-
SEVPPXL=] [,ALRMSEVPPXU=] [,ALRMSEVCPEX=]
[,ALRMSEVFAN=] [,ALRMSEVES=] [,SALUNAME=] [,EQU-
POS=] [,EAUTOREC=];


A30808-X3247-M230-6-7619

179
CML:BSC BSCE
Id:0900d805800d5341
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to set the following BSCE parameters:
the alarms severity associated to hardware objects;
the attributes needed to control the data related to BSCE remote inventory.
These remote inventory information are not saved into DBA file but saved into BSC-
DATA.RI file in REM_INV_DIR directory. When the file is not present the attributes
assume their default values.
Long Names:
NAME Addres of the managed object
ALRMSEVDISK alarmSeverityDisk
ALRMSEVDK40 alarmSeverityDk40
ALRMSEVEPWR alarmSeverityEpwr
ALRMSEVIXLT alarmSeverityIxlt
ALRMSEVLICD alarmSeverityLicd
ALRMSEVLICDS alarmSeverityLicds
ALRMSEVMEMT alarmSeverityMemt
ALRMSEVMPCC alarmSeverityMpcc
ALRMSEVNTW alarmSeverityNtw
ALRMSEVPWRD alarmSeverityPwrd
ALRMSEVSYNC alarmSeveritySync
ALRMSEVSYNE alarmSeveritySyne
ALRMSEVTDPC alarmSeverityTdpc
ALRMSEVX25A alarmSeverityX25a
ALRMSEVX25D alarmSeverityX25d
ALRMSEVPPXL alarmSeverityPpxl
ALRMSEVPPXU alarmSeverityPpxu
ALRMSEVCPEX alarmSeverityCPEX
ALRMSEVFAN alarmSeverityFAN
ALRMSEVES alarmSeverityES
SALUNAME salesUniqueName
EQUPOS equipmentPosition
EAUTOREC enableAutoRecovery
System Responses:
- Operation Completed
Successful


180 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5341
BSCE
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set BSCE:NAME=BSCE:0,ALRMSEVLICD=CRITICAL,
ALRMSEVX25A=MINOR,SALUNAME="AD042S7449F", EQUPOS="010101", EAU-
TOREC=DISABLED;
STOPTEST BSCE
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE STOPTEST BSCE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that executes the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
MORT MOT
TO testObject
System Responses:
- Operation Completed
UNSUCCESSFUL_FILE_SYSTEM_ERROR
A file system error occurs during the DK40 access.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The salesUniqueName parameter must be 11 characters long and
the equipmentPosition parameter must be 6 characters long.
STOPTEST BSCE NAME=BSCE:0..0 [,MORT=] ,TO=;
STOPTEST DISK:NAME=DISK:0;
testObject=BSCETEST:<n>


A30808-X3247-M230-6-7619

181
CML:BSC BSCE
Id:0900d805800d5341
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest BSCE:NAME=BSCE:0,MORT=PPXX:0,TO=BSCETEST:5;
Result BSCETEST:
name = BSCETEST:<n>
testOutcome = inconclusive
mOts = DISK:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; the list
is not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


182 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41ed
BSCESUDB
BSCESUDB
The BSCESUDB (BSC Executable Software Unit DB) object represents a logical con-
tainer roughly corresponding to a directory containing Data Base files, identified by Data
Base Replaceable Software Units.
The addressing scheme is applicable (20 instances for this object are allowed); the
object is automatically created at the corresponding RSUDB (Replaceable Software
Unit Data Base) creation, only attribute values can be changed.
All related commands consist of two fields but only one can be used (NAME or USER
LABEL DB).
GET BSCESUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GET
BSCESUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
IDBSCESUDB Addres of the managed object
IDBSCESUDB identifierBSCESUDB
ULAB userLabel
RELRSU relatedRSU
DBVER dbVersion
System Responses:
- Operation Completed
GET BSCESUDB BASICS
GET BSCESUDB IDBSCESUDB= [,REQATTL= ULAB ,RELRSU ,DBVER];
ULAB: userLabel
RELRSU: relatedRSU
DBVER: dbVersion
ULAB: userLabel


A30808-X3247-M230-6-7619

183
CML:BSC BSCESUDB
Id:0900d805800d41ed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET BSCESUDB BASICS
None.
Example of Command Execution:
Get BSCESUDB:NAME=BSCESUDB:0,REQATTL=ULAB&RELRSU&DBVER;
Get BSCESUDB:IDBSCESUDB="userLabel",
REQATTL=ULAB&RELRSU&DBVER;
GET BSCESUDB BASICS
Get BSCESUDB BASICS:NAME=BSCESUDB:0;
Get BSCESUDB BASICS:IDBSCESUDB="userLabel";
GET BSCESUDB BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GET
BSCESUDB BASICS
RELRSU: relatedRSU
DBVER: dbVersion
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
The command is rejected due to an internal subsystem abort.
GET BSCESUDB
BASICS
;


184 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41ed
BSCESUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
IDBSCESUDB Addres of the managed object
ULAB userLabel
RELRSU relatedRSU
DBVER dbVersion
System Responses:
See GET BSCESUDB
Application Guidelines:
See GET BSCESUDB
Example of Command Execution:
See GET BSCESUDB
GET BSCESUDB STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GET
BSCESUDB STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
BSCESUDB object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
GET BSCESUDB STAT IDBSCESUDB=;


A30808-X3247-M230-6-7619

185
CML:BSC BSCESUDB
Id:0900d805800d41ed
Long Names:
IDBSCESUDB Addres of the managed object
IDBSCESUDB identifierBSCESUDB
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get BSCESUDB STAT:NAME=BSCESUDB:0;
Get BSCESUDB STAT:IDBSCESUDB="userLabel";
GETINFO BSCESUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUDB GETINFO
BSCESUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information about a single DB instance:
1. For the RSUDB object related to the BSCESUDB:
RSUDB instance identifier,
User label,
Version,
Related files,
Operational state;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.
GETINFO BSCESUDB IDBSCESUDB=;


186 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41ed
BSCESUDB
2. Information about the role of the BSCESUDB in the BSCOSUDB.
Long Names:
IDBSCESUDB Addres of the managed object
IDBSCESUDB identifierBSCESUDB
System Responses:
- Operation Completed
GETINFO BSCESUDB ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT BSCESUDB:
NAME = BSCESUDB:1
RUNNING ESUDB INSTANCE: 0
USER LABEL: EFESTOBR61_OLD_09
VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995
RELATED FILES: DBFILE_OLD.DBA
OPERATIONAL STATE: ENABLED
USED AS: RUNNINGESU
END OF REPORT
NOTE: the DB VERSION may be unavailable; in this case the default value to display is
... ...
VERSION: NOT_AVAILABLE 00:00:00 01/01/1970
- Operation Failed
GETINFO BSCESUDB NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack BSCESUDB:
name = BSCESUDB:1
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.


A30808-X3247-M230-6-7619

187
CML:BSC BSCESUDB
Id:0900d805800d41ed
Application Guidelines:
The attribute "relatedFiles" displays only the file name without the complete BSC disk
storage path.
Example of Command Execution:
Getinfo BSCESUDB:NAME=BSCESUDB:0;
Getinfo BSCESUDB:IDBSCESUDB="userLabel";
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


188 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d67aa
BSCESUSW
BSCESUSW
The BSCESUSW (BSC Executable Software Unit SW) object represents a logical "con-
tainer" corresponding to a directory containing the software load header files,
identified by Software Load Header Replaceable Software Units.
The addressing scheme is applicable (20 instances for this object is allowed); the object
is automatically created at the corresponding RSUSWLH (Raplaceable Software Unit
SW Load Header) creation, only attribute values can be changed.
All related commands consist of two fields but only one can be used (NAME or USER
LABEL SWLH).
GET BSCESUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GET
BSCESUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
IDBSCESUSW Addres of the managed object
IDBSCESUSW identifierBSCESUSW
ULAB userLabel
VER version
RELRSU relatedRSU
System Responses:
- Operation Completed
GET BSCESUSW BASICS
GET BSCESUSW IDBSCESUSW= [,REQATTL= ULAB ,VER ,RELRSU];
ULAB: userLabel
VER: version
RELRSU: relatedRSU
ULAB: userLabel


A30808-X3247-M230-6-7619

189
CML:BSC BSCESUSW
Id:0900d805800d67aa
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET BSCESUSW BASICS
None.
Example of Command Execution:
Get BSCESUSW:NAME=BSCESUSW:0,REQATTL=ULAB&VER&RELRSU;
Get BSCESUSW:IDBSCESUSW="userLabel",REQATTL=ULAB&VER&RELRSU;
GET BSCESUSW BASICS
Get BSCESUSW BASICS:NAME=BSCESUSW:0;
Get BSCESUSW BASICS:IDBSCESUSW="userLabel";
GET BSCESUSW BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GET
BSCESUSW BASICS
Applicability:
Phase 2.
VER: version
RELRSU: relatedRSU
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal system abort has occurred.
GET BSCESUSW
BASICS
;


190 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d67aa
BSCESUSW
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
IDBSCESUSW Addres of the managed object
ULAB userLabel
VER version
RELRSU relatedRSU
System Responses:
See GET BSCESUSW
Application Guidelines:
See GET BSCESUSW
Example of Command Execution:
See GET BSCESUSW
GET BSCESUSW STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GET
BSCESUSW STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
BSCESUSW object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
IDBSCESUSW Addres of the managed object
IDBSCESUSW identifierBSCESUSW
GET BSCESUSW STAT IDBSCESUSW=;


A30808-X3247-M230-6-7619

191
CML:BSC BSCESUSW
Id:0900d805800d67aa
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get BSCESUSW STAT:NAME=BSCESUSW:0;
Get BSCESUSW STAT:IDBSCESUSW="userLabel";
GETINFO BSCESUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCESUSW GETINFO
BSCESUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information about a SW version:
1. Information about the RSUSWLH object related to the BSCESUSW:
RSUSWLH Instance identifier,
User label associated,
Version number,
Related files,
Operational state;
2. For each executable file RSUEXE present in the SW load header:
RSUEXE instance identifier,
Processor type,
Version number,
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.
GETINFO BSCESUSW IDBSCESUSW=;


192 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d67aa
BSCESUSW
Related files,
Operational state;
3. For each patch file RSUPCH present (if any):
RSUPCH instance identifier,
Processor type,
User label associated,
Permanent attribute,
Related files,
Operational state,
Availability status;
4. Information about the use of the BSCESUSW (i.e. running, backup, etc.).
( I ) If the LMT is connected in remote mode, it is not possible to execute this command.
Long Names:
IDBSCESUSW Addres of the managed object
IDBSCESUSW identifierBSCESUSW
System Responses:
- Operation Completed
GETINFO BSCESUSW ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT:
NAME = BSCESUSW:1
SBS RSUSWLH INSTANCE: 0
USER LABEL: 02-06-01-01-00-40_01-08-31
VERSION: 02-06-01-01-00-40_01-08-31
RELATED FILES: HB010400.SWL
OPERATIONAL STATE: ENABLED

SBS RSUEXE INSTANCE: 0-1
SBS PROCTYPE: TDPC
VERSION: 02-06-01-01-21-00_01-08-31
RELATED FILES: T12100.ABS
OPERATIONAL STATE: ENABLED

... ...


A30808-X3247-M230-6-7619

193
CML:BSC BSCESUSW
Id:0900d805800d67aa
SBS RSUEXE INSTANCE: 0-7
SBS PROCTYPE: IXLT
VERSION: 02-06-01-01-21-00_01-08-31
RELATED FILES: X12100.ABS
OPERATIONAL STATE: ENABLED

SBS RSUPCH INSTANCE: 0-3-0
SBS PROCTYPE: MPCC
USER LABEL: MEB00
SBS PERMANENT: TRUE
RELATED FILES: M2610000.PCH
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: OFF_DUTY

SBS RSUPCH INSTANCE: 0-1-1
SBS PROCTYPE: TDPC
USER LABEL: TEB00
SBS PERMANENT: TRUE
RELATED FILES: T2610000.PCH
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: OFF_DUTY

... ...
SBS RSUPCH INSTANCE: 0-3-1
SBS PROCTYPE: MPCC
USER LABEL: MEB16
SBS PERMANENT: TRUE
RELATED FILES: M2610001.PCH
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: OFF_DUTY

USED AS: NOT USED

END OF REPORT
- Operation Failed
GETINFO BSCESUSW NACK:
BSC_CONTROLLER -> LMT_LOCAL


194 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d67aa
BSCESUSW
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack BSCESUSW:
name = BSCESUSW:1
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
1. The attribute "relatedFiles" displays only the file name without the complete BSC
disk storage path.
2. For each RSUPCH with PCH extension the related RSUPCH with BAK extension (if
any) is showed immediately after.
Example of Command Execution:
Getinfo BSCESUSW:NAME=BSCESUSW:0;
Getinfo BSCESUSW:IDBSCESUSW="userLabel";
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

195
CML:BSC BSCETEST
Id:0900d805800d41f3
BSCETEST
The BSCETEST locates a test object in the BSS system; this object is created when an
activation of a diagnostic occurs.
GET BSCETEST
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCETEST GET BSCETEST
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start an
asynchronous test and is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GET BSCETEST NAME=BSCETEST:0..255;
GET BSCETEST:NAME=BSCETEST:<n>;
name = BSCETEST:<n>
mOts = EPWR:0
bscetestState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
bscetestOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
bscetestMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.


196 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41f3
BSCETEST
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get BSCETEST:NAME=BSCETEST:0,MOT=DK40:0;
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


A30808-X3247-M230-6-7619

197
CML:BSC BSCOSUDB
Id:0900d805800d41f7
BSCOSUDB
The BSCOSUDB (BSC Operational Software Unit DB) object is related to the Data Base
present on the BSC disk. Its attributes respectively identify the running, backup, new,
fallback Data Base and Data Base backup pending information.
The addressing scheme is not applicable (only 1 instance for this object is allowed); the
object is automatically created and only the attribute values can be changed.
GET BSCOSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB GET
BSCOSUDB
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
NEWESU newESU
FALLBESU fallbackESU
DBBKPPEN dbBackupPending
System Responses:
- Operation Completed
GET BSCOSUDB NAME=BSCOSUDB:0..0 [,REQATTL= RUNESU ,BCK-
UPESU ,NEWESU ,FALLBESU ,DBBKPPEN];
RUNESU: runningESU
BCKUPESU: backupESU
NEWESU: newESU
FALLBESU: fallbackESU
DBACKPEND: dbBackupPending


198 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41f7
BSCOSUDB
GET BSCOSUDB BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET BSCOSUDB BASICS
None.
Example of Command Execution:
Get BSCOSUDB:NAME=BSCOSUDB:0,REQATTL=RUNESU&BCKUPESU&
NEWESU&FALLBESU&DBACKPEND;
GET BSCOSUDB BASICS
Get BSCOSUDB BASICS:NAME=BSCOSUDB:0;
GET BSCOSUDB BASICS
RUNESU: runningESU
BCKUPESU: backupESU
NEWESU: newESU
FALLBESU: fallbackESU
DBACKPEND: dbBackupPending
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
GET BSCOSUDB
BASICS
NAME=BSCOSUDB:0..0;


A30808-X3247-M230-6-7619

199
CML:BSC BSCOSUDB
Id:0900d805800d41f7
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB GET
BSCOSUDB BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
NEWESU newESU
FALLBESU fallbackESU
DBBKPPEN dbBackupPending
System Responses:
See GET BSCOSUDB
Application Guidelines:
See GET BSCOSUDB
Example of Command Execution:
See GET BSCOSUDB
GETINFO BSCOSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB GETINFO
BSCOSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information related to the BSCESUDB
set as 'runningESU', 'backupESU', newESU' and 'fallbackESU':
GETINFO BSCOSUDB NAME=BSCOSUDB:0..0;


200 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41f7
BSCOSUDB
1. For each running ESU present in the system:
BSCESUDB instance identifier,
User label associated,
Version number,
Operational state;
2. For each backup ESU present in the system:
BSCESUDB instance identifier,
User label associated,
Version number,
Operational state;
3. For each new ESU present in the system:
BSCESUDB instance identifier,
User label associated,
Version number,
Operational state;
4. For each fallback ESU present in the system:
BSCESUDB instance identifier,
User label associated,
Version number,
Operational state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO BSCOSUDB ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT BSCOSUDB:
NAME = BSCOSUDB:1
RUNNING ESUDB INSTANCE: 0
USER LABEL: EFESTOBR61_OLD_09
VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995
OPERATIONAL STATE: ENABLED

BACKUP ESUDB INSTANCE: 0
USER LABEL: EFESTOBR61_OLD_09


A30808-X3247-M230-6-7619

201
CML:BSC BSCOSUDB
Id:0900d805800d41f7
VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995
OPERATIONAL STATE: ENABLED

FALLBACK ESUDB INSTANCE: 0
USER LABEL: EFESTOBR61_OLD_09
VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995
OPERATIONAL STATE: ENABLED

NEW ESUDB INSTANCE: 0
USER LABEL: EFESTOBR61_OLD_09
VERSION: SBS-M-262-1-09-01 17:18:27 01/01/1995
OPERATIONAL STATE: ENABLED

END OF REPORT
NOTE: the VERSION fields in ESU descriptions may be unavailable; in this case the
default value to display is the following
... ...
VERSION: NOT_AVAILABLE 00:00:00 01/01/1970
- Operation Failed
GETINFO BSCOSUDB NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack BSCOSUDB:
name = BSCOSUDB:1
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


202 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41f7
BSCOSUDB
Application Guidelines:
None.
Example of Command Execution:
Getinfo BSCOSUDB:NAME=BSCOSUDB:1;
SAVEDB BSCOSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB SAVEDB
BSCOSUDB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command triggers save BSC Data Base operational sequence.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
The system must be in normal exercise (no other operation is in progress).
Example of Command Execution:
Savedb BSCOSUDB:NAME=BSCOSUDB:0;
SET BSCOSUDB
SAVEDB BSCOSUDB NAME=BSCOSUDB:0..0;
CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS
The system is not in normal exercise (another command is in
progress).
SET BSCOSUDB NAME=BSCOSUDB:0..0 ,IDBSCESUDB= ,ACTN=;


A30808-X3247-M230-6-7619

203
CML:BSC BSCOSUDB
Id:0900d805800d41f7
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB SET
BSCOSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs an assignment of a Database instance to one of the following
attributes:
backupESU OSUDB attribute (BCKUPESU), i.e. the selected software load
becomes the "backup" software load, or
fallbackESU OSUDB attribute (FALLBESU), i.e. the selected software load
becomes the "fallback" software load, or
newESU OSUDB attribute (NEWESU), i.e. the selected software load becomes the
"new" software load.
When runningESU OSUDB attribute (RUNESU) is selected, this command performs a
Load Database from newESU OSUDB attribute when the object address "bscosudbn"
corresponds to the object address contained into newESU OSUDB attribute only.
Note that the above-mentioned object address is different from the address of the
BSCOSUDB object, which can assume the 0 value only (see below).
In the other cases a Nack to this command is given.
That is:
the command:
SET BSCOSUDB NAME="bscosudbn" ACTN=RUNNING_ESU
(where "bscosudbn" is the object address contained into newESU) corresponds to the
command: SETRUNNEW BSCOSUDB (see the related command description and nack
causes)
This command consists of two fields but only one can be used (NAME or USER LABEL
DB).
Long Names:
NAME Addres of the managed object
IDBSCESUDB identifierBSCESUDB
ACTN action
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
CMD_NOT_ALLOWED_IN_CURRENT_PHASE
The system is not in normal exercise.


204 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41f7
BSCOSUDB
Application Guidelines:
1. The system must be in normal exercise (no other operation is in progress).
2. The OperationalState attribute of the MEID passed by the command must be
ENABLED.
3. The Data Base version has to be compatible with the software to load.
4. The OperationalState of the BSCOSUDB newESU attribute must be ENABLED.
5. If the backupESU software is not NULL, the generic Data Base instance entered
must be compatible with it.
Example of Command Execution:
Set BSCOSUDB:NAME=BSCOSUDB:0,
IDBSCESUDB=BSCESUDB:0,ACTN=FALLBACK_ESU;
Set BSCOSUDB:NAME=BSCOSUDB:0,
IDBSCESUDB="userLabel",ACTN=FALLBACK_ESU;
SETRUNNEW BSCOSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUDB SETRUN-
NEW BSCOSUDB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command loads the Data Base marked as "new", i.e. the Data Base that was
marked as "new" becomes the "running" one.
Long Names:
NAME Addres of the managed object
RELATED_OBJECTS_DISABLED
The ESUDB MEID object passed by the command is DISABLED.
INCOMPATIBLE_DBA_VERSION
The Data Base is not compatible with the corresponding backupESU
SW (or newESU SW, or fallbackESU SW).
NO_ADMITTED_OPERATION
The MEID object passed is not a valid one for the specific command.
SETRUNNEW
BSCOSUDB
NAME=BSCOSUDB:0..0;


A30808-X3247-M230-6-7619

205
CML:BSC BSCOSUDB
Id:0900d805800d41f7
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The system must be in normal exercise (no other operation is in progress).
2. The OperationalState of the BSCOSUDB newESU attribute must be ENABLED.
3. The Database version has to be compatible with the software to load.
4. In the above mentioned case the system automatically reloads the Data Base
marked as "backup"; if also this operation fails the system automatically performs a
Bring Up. If the system does not manage to load the Data Base marked as "backup",
it loads the Data Base with default values.
Since default value of NTWCARD parameter is NTWSN16, before loading a Data
Base with NTWCARD = NTWSNAP the operator has to perform one of the two fol-
lowing actions (otherwise the Nack Cause is displayed again):
Set NTWCARD at NTWSNAP value (by means of SET BSC command), then
load the Data Base again (by means of SETRUNNEW BSCOSUDB command);
Set the Data Base to be loaded as "backup" (by means of SET BSCOSUDB
command) and then perform a Full Bring Up.
CMD_NOT_ALLOWED_IN_CURRENT_PHASE
The system is not in normal exercise.
NO_ADMITTED_OPERATION
The MEID object passed is not a valid one for the specific command.
The backupESU SW is null.
The backupESU DB is null.
The runningESU and backupESU of BSCOSUDB are not equal.
An ESU can be set as running only if it is already the newESU.
The specific ESU DB is not compatible with the rack type.
The specified BSCESUDB is not compatible with the NTW type indi-
cated in NTWCARD parameter of BSC object. For further details see
Application Guideline n. 4.
RELATED_OBJECTS_DISABLED
The ESUDB MEID object passed by the command is DISABLED.
The ESUDB MEID object contained in backupESU is DISABLED.
INCOMPATIBLE_DBA_VERSION
The Data Base is not compatible with the corresponding newESU
SW.


206 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41f7
BSCOSUDB
Example of Command Execution:
Setrunnew BSCOSUDB:NAME=BSCOSUDB:0;


A30808-X3247-M230-6-7619

207
CML:BSC BSCOSUSW
Id:0900d805800d41fa
BSCOSUSW
The BSCOSUSW (BSC Operational Software Unit SW) object is related to the software
loads present on the BSC disk. Its attributes respectively identify the running, backup,
new and fallback software load; an additional attribute is used to identify the current
loading phase.
The addressing scheme is not applicable (only 1 instance for this object is allowed); the
object is automatically created and only the attribute values can be changed.
GET BSCOSUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW GET
BSCOSUSW
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
NEWESU newESU
FALLBESU fallbackESU
PH phase
System Responses:
- Operation Completed
GET BSCOSUSW NAME=BSCOSUSW:0..0 [,REQATTL= RUNESU ,BCK-
UPESU ,NEWESU ,FALLBESU ,PH];
RUNESU: runningESU
BCKUPESU: backupESU
NEWESU: newESU
FALLBESU: fallbackESU
PH: phase


208 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
GET BSCOSUSW BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET BSCOSUSW BASICS
None.
Example of Command Execution:
Get BSCOSUSW:NAME=BSCOSUSW:0,
REQATTL=RUNESU&BCKUPESU&NEWESU&FALLBESU&PH;
GET BSCOSUSW BASICS
Get BSCOSUSW BASICS:NAME=BSCOSUSW:0;
RUNESU: runningESU
BCKUPESU backupESU
NEWESU: newESU
FALLBESU: fallbackESU
PH: phase
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.


A30808-X3247-M230-6-7619

209
CML:BSC BSCOSUSW
Id:0900d805800d41fa
GET BSCOSUSW BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW GET
BSCOSUSW BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
NEWESU newESU
FALLBESU fallbackESU
PH phase
System Responses:
See GET BSCOSUSW
Application Guidelines:
See GET BSCOSUSW
Example of Command Execution:
See GET BSCOSUSW
GETINFO BSCOSUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW GETINFO
BSCOSUSW
Applicability:
Phase 2.
Visibility level: 2.
GET BSCOSUSW
BASICS
NAME=BSCOSUSW:0..0;
GETINFO BSCOSUSW NAME=BSCOSUSW:0..0;


210 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
Command Description:
This command is used to retrieve the following information about the BSCESUSW cor-
responding to 'runningESU' or 'backupESU' or 'newESU' or 'fallbackESU' attribute:
1. For each running ESU present in the system:
BSCESUSW instance identifier,
User label associated,
Version number,
Operational state;
2. For each backup ESU present in the system:
BSCESUSW instance identifier,
User label associated,
Version number,
Operational state;
3. For each new ESU present in the system:
BSCESUSW instance identifier,
User label associated,
Version number,
Operational state;
4. For each fallback ESU present in the system:
BSCESUSW instance identifier,
User label associated,
Version number,
Operational state;
5. Information about the load usage state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO BSCOSUSW ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT BSCOSUSW:
NAME = BSCOSUSW:1
RUNNING ESU INSTANCE: 0
USER LABEL: 62BSCHB010024
VERSION: 02-06-02-01-00-24_01-12-19
OPERATIONAL STATE: ENABLED


A30808-X3247-M230-6-7619

211
CML:BSC BSCOSUSW
Id:0900d805800d41fa

BACKUP ESU INSTANCE: 0
USER LABEL: 62BSCHB010024
VERSION: 02-06-02-01-00-24_01-12-19
OPERATIONAL STATE: ENABLED

FALLBACKUP ESU INSTANCE: 0
USER LABEL: 26207LOAD19
VERSION: 02-06-02-01-00-19_01-11-19
OPERATIONAL STATE: ENABLED

NEW ESU INSTANCE: 0
USER LABEL: 26207LOAD19
VERSION: 02-06-02-01-00-19_01-11-19
OPERATIONAL STATE: ENABLED

LOAD USAGE STATE: IDLE
END OF REPORT
- Operation Failed
GETINFO BSCOSUSW NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack BSCOSUSW:
name = BSCOSUSW:1
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE


212 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
Application Guidelines:
None.
Example of Command Execution:
Getinfo BSCOSUSW:NAME=BSCOSUSW:1;
SET BSCOSUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SET
BSCOSUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs an assignment of a generic software load to:
backupESU BSCOSUSW attribute (BACKUPESU), or
fallbackESU BSCOSUSW attribute (FALLBESU), or
newESU BSCOSUSW attribute (NEWESU) .
When runningESU BSCOSUSW attribute (RUNESU) is selected, this command per-
forms:
a Change Version when the object address "bscosuswn" corresponds to the object
address contained into newESU BSCOSUSW attribute and the system is in normal
exercise.
a Load System (Bring Up) when the object address "bscosuswn" corresponds to the
object address contained into backupESU BSCOSUSW attribute and the system is
in normal exercise (BSCOSUSW LoadUsageState attribute set at IDLE).
a Rollback when the object address "bscosuswn" corresponds to the object address
contained into backupESU BSCOSUSW attribute and the system is during a
Change Version (BSCOSUSW LoadUsageState attribute set at LoadNewESUsw or
waitForAcceptNewESUsw).
Note that the above-mentioned object address is different from the address of the
BSCOSUSW object, which can assume the 0 value only (see below).
In all the other cases a Nack to this command is given.
That is:
the command:
SET BSCOSUSW NAME="bscosuswn" ACTN=RUNNING_ESU
(where "bscosuswn" is the object address contained into backupESU)
If there are 10 Getinfo commands already in progress.
SET BSCOSUSW NAME=BSCOSUSW:0..0 ,IDBSCESUSW= ,ACTN=;


A30808-X3247-M230-6-7619

213
CML:BSC BSCOSUSW
Id:0900d805800d41fa
corresponds to the command:
SETRUNBACK BSCOSUSW
(see the related command description and nack causes)
Whereas:
the command:
SET BSCOSUSW NAME="bscosuswn" ACTN=RUNNING_ESU
(where "bscosuswn" is the object address contained into newESU)
corresponds to the command:
SETRUNNEW BSCOSUSW
(see the related command description and nack causes)
This command consists of two fields but only one can be used (NAME or USER LABEL
SWLH).
Long Names:
NAME Addres of the managed object
IDBSCESUSW identifierBSCESUSW
ACTN action
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The system must be in normal exercise (no other operation is in progress).
2. If a generic software download is performed, in BACKUP directory, and it is not com-
patible with the corresponding Data Base of BSCOSUDB backupESU attribute, the
attribute is set at NULL and an error message is displayed.
For a generic software load to newESU or fallbackESU attribute, the nack causes are:
CMD_NOT_ALLOWED_IN_CURRENT_PHASE
The BSCOSUSW LoadUsageState attribute is not IDLE.
NO_ADMITTED_OPERATION
The MEID object passed is not a valid one for the specific command.
RELATED_OBJECTS_DISABLED
The ESUSW MEID object passed by the command is DISABLED.
INCONSISTENT_STATE_NCK
An error during a Firmware function call happened.
DISK_CROSSCOPY_IN_PROGRESS
A disk crosscopy operation is in progress.


214 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
3. If a generic software download is performed, in NEW directory, and it is not
compatible with the corresponding Data Base of BSCOSUDB newESU attribute, the
attribute is set at NULL and an error message is displayed.
4. If a generic software download is performed, in FALLBACK directory, and it is not
compatible with the corresponding Data Base of BSCOSUDB fallbackESU attribute,
the attribute is set at NULL and an error message is displayed.
5. The system must be able to make actual the SW assignment also in the specific
Firmware partition (SYS_BACKUP).
Example of Command Execution:
Set BSCOSUSW:NAME=BSCOSUSW:0,
IDBSCESUSW=BSCESUSW:0,ACTN=FALLBACK_ESU;
Set BSCOSUSW:NAME=BSCOSUSW:0,
IDBSCESUSW="userLabel",ACTN=FALLBACK_ESU;
SETBACKNEW BSCOSUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SETBACK-
NEW BSCOSUSW
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command performs an "end of change version" procedure or it is used to set
generic software load at BSCOSUSW backupESU attribute.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
SETBACKNEW
BSCOSUSW
NAME=BSCOSUSW:0..0;
UNSUCCESSFUL_COMMAND_REJECTED
An error during a function call happened.
DISK_CROSSCOPY_IN_PROGRESS
A disk crosscopy operation is in progress.


A30808-X3247-M230-6-7619

215
CML:BSC BSCOSUSW
Id:0900d805800d41fa
Application Guidelines:
If the system is in a "end of change version" phase, the command is performed when:
the LoadUsageState of the BSCOSUSW attribute is equal to
WAIT_FOR_ACCEPT_NEW_ESUSW;
the OperationalState of BSCOSUSW newESU attribute is ENABLED.
no crosscopy disks operation is in progress;
if also MPCC was involved in Change Version, then BSCOSUDB newESU attribute
must have OperationalState attribute ENABLED.
Example of Command Execution:
Setbacknew BSCOSUSW:NAME=BSCOSUSW:0;
SETRUNBACK BSCOSUSW
CMD_NOT_ALLOWED_IN_CURRENT_PHASE
The BSCOSUSW loadUsageState attribute is not
waitForAcceptNewESUsw (for End of Change Version command
only).
The BSCOSUSW loadUsageState attribute is not IDLE (for the Set
generic SW load to backupESU command only).
NO_ADMITTED_OPERATION
The MEID object passed is not a valid one for the specific command.
The Change Version procedure was started from Radio Commander
but the OMAL is still down (for End of Change Version only).
The newESU SW is null (for End of Change Version only).
The newESU DB is null (for End of Change Version with BU only).
RELATED_OBJECTS_DISABLED
newESU SW is DISABLED (for End of Change Version command
only).
newESU DB is DISABLED (for End of Change Version command
only).
The object ESUSW MEID passed by the command is DISABLED (for
the Set generic SW load to backupESU command only).
INCONSISTENT_STATE_NCK
An error during a Firmware function call happened (for the Set generic
SW load to backupESU command only)
SETRUNBACK
BSCOSUSW
NAME=BSCOSUSW:0..0;


216 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SETRUN-
BACK BSCOSUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs a "bring-up" or "roll-back" procedure.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the command is used to perform a Bring Up procedure the OperationalState of the
BSCOSUSW backup ESU attribute must be ENABLED and the number of MPCC
CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS
Bring Up in progress.
UNSUCCESSFUL_COMMAND_REJECTED
An error during a function call happened.
NO_ADMITTED_OPERATION
The MEID object passed is not a valid one for the specific command.
MPCC and OB disk providing service copy numbers are not aligned.
T_REQUEST_ALREADY_IN_PROGRESS
A rollback command is already in progress.
INCONSISTENT_STATE_NCK
Mismatch between command and phase.
RELATED_OBJECTS_DISABLED
backupESU SW is DISABLED.
CMD_NOT_ALLOWED_IN_CURRENT_PHASE
The BSCOSUSW loadUsageState attribute is neither
LoadNewESUsw nor waitForAcceptNewESUsw (for rollback
command only).


A30808-X3247-M230-6-7619

217
CML:BSC BSCOSUSW
Id:0900d805800d41fa
copy providing service must be equal to the number of the On-board disk copy pro-
viding service.
2. If the LoadUsageState attribute value is equal to:
IDLE, this command performs a Bring Up (Load System);
LOAD_NEW_ESU_SW or WAIT_FOR_ACCEPT_NEW_ESU_SW, this
command performs a Rollback procedure. In the former case the Rollback
command is immediately executed, in the latter case al the loading operations
in progress are aborted and the requested Rollback command is scheduled. If
also MPCC was involved in the specific Change Version, then the number of
MPCC copy providing service must be equal to the number of the On-board disk
copy providing service;
other value, this command is rejected because there a mismatch beetwen the
command and LoadUsageState attribute.
Example of Command Execution:
Setrunback BSCOSUSW:NAME=BSCOSUSW:0;
SETRUNNEW BSCOSUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT BSCOSUSW SETRUN-
NEW BSCOSUSW
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command triggers a Change Version procedure.
The Change Version procedure allows the user to load a new software release.
If the MPCC software has to be changed, a Bring Up will start.
If the TDPC software has to be changed, both TDPC processor copies will be loaded
with the new software, losing the traffic service for about 2 minutes: at the end of the
command one copy is enabled with the new software and crosscopy operation from the
TDPC active to the standby one is in progress.
If the IXLT software has to be changed:
if both the IXLTs are enabled, only the card not providing service is loaded with the
new software, and the service is lost only for the switching time between the two pro-
cessor copies. At the end of the command the copy with the new software is provid-
ing service, the other copy is disabled with the old software and it is
automatically loaded when the SETBACKNEW BSCOSUSW command is entered
if one of the IXLTs is not enabled, the command is not executed.
SETRUNNEW
BSCOSUSW
NAME=BSCOSUSW:0..0;


218 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
If the PPXL software has to be changed:
if both PPXLs are enabled, only the copy provided by the Device Handler is loaded
with the new software, and the service is lost only for the switching time between the
two processor copies. At the end of the command the copy with the new software is
enabled, the other copy is disabled with the old software and it is automatically
loaded when the SETRUNNEW BSCOSUSW command is entered
if one of the PPXLs is not enabled, the command is not executed.
If the PPXU software has to be changed:
if at least two PPXUs are enabled, half of the copies are loaded with the new soft-
ware, and the service is lost only for the switching time between the two processor
groups (the one with old software and the one with new software). At the end of the
command all equipped PPXUs are loaded with the new software and enabled, the
other processor group is disabled with the old software and it is automatically loaded
when the SETBACKNEW BSCOSUSW command is entered.
if only one PPXU is enabled, the command is not executed.
The procedure does not involve software change for the SNAP card.
The command works only if the system is in normal exercise.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS
Another operation is already in progress.
UNSUCCESSFUL_COMMAND_REJECTED
An error during a function call happened.
NO_ADMITTED_OPERATION
The MEID object passed is not a valid one for the specific command.
The runningESU SW and the backupESU SW are not aligned.
MPCC and OB Disk providing service copy numbers are not aligned
(for Change Version with BU only).
No object instance is linked to new ESU attribute (for Change Version
with BU only).
An ESU can be set as running only if it is already the backupESU or
newESU.
The backupESU SW is null.
The specific newESU DB is not compatible with the Network type (for
Change Version with BU only).


A30808-X3247-M230-6-7619

219
CML:BSC BSCOSUSW
Id:0900d805800d41fa
Application Guidelines:
1. The system must be in normal exercise (no other operation is in progress).
2. The following state conditions must be satisfied:
Load UsageState BSCOSUSW attribute must be IDLE;
OperationalState BSCOSUSW backupESU must be ENABLED;
OperationalState BSCOSUSW newESU must be ENABLED;
the BSCOSUSW backupESU and BSCOSUSW runningESU attributes must be
equal.
3. If also the MPCC processor is involved in Change Version procedure then:
the BSCOSUDB newESU must be present and its OperationalState attribute
must be ENABLED;
the number of MPCC providing service copy must be equal to the number of the
On-Board disk providing service copy;
T_REQUEST_ALREADY_IN_PROGRESS
A Change Version command is already in progress.
INCONSISTENT_STATE_NCK
Mismatch between command and phase.
The set of MPCC/TDPC/PPXL/PPXU running patches are not equal
to that one of permanent patches.
The RSUEXE for the processor PPXL or PPXU contained in the new
ESU is DISABLED or missing.
CMD_NOT_ALLOWED_IN_CURRENT_PHASE
The BSCOSUSW loadUsageState attribute is not IDLE.
RELATED_OBJECTS_DISABLED
backupESU SW is DISABLED.
newESU SW is DISABLED.
newESU DB is DISABLED.
DISK_CROSSCOPY_IN_PROGRESS
A disk crosscopy operation is in progress.
NO_MINIMAL_CARD_REDUNDANCY
IXLT processor is not in duplex.
no IXLT processor providing service.
no MPCC processor providing service.
no TDPC processor providing service.
PPXL processor is not in duplex.
PPXU processor is not in duplex.
no PPXL processor providing service.
no PPXU processor providing service.


220 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d41fa
BSCOSUSW
at least one copy for each processor type must be providing service.
4. If the IXLT, PPXL, and PPXU processors are involved in Change Version procedure
then they must be in duplex mode, all cards must be in UNLOCKED-ENABLED state
and at least one copy must be providing service.
5. The OperationalState attribute of all the RSUEXE objects related to the peripheral
processor type foreseen in that BSC HW configuration and contained in the ESUSW
must be ENABLED. This check is performed on peripheral processor type having at
least one copy equipped only.
6. If the MEID object passed to the command by LMT system is equal to that one of
backup BSCOSUSW, this command performs a Bring-Up procedure instead of a
Change Version procedure.
7. The processors involved in Change Version operation are:
those ones whose Software Version (SVR) is changed from backupESU to new
ESU;
those ones whose set of permanent patches related to backupESU is different
from set of permanent patches related to newESU.
If no processor is involved in change version (according to the conditions just
listed) or change version regards not eqiopped optional peripheral processors
only (i.e.: PPXU), then the change version is anyway accepted like an adminis-
trative chenge version operation (i.e.: a change version operation in which no
processor loading is made).
Example of Command Execution:
Setrunnew BSCOSUSW:NAME=BSCOSUSW:0;


A30808-X3247-M230-6-7619

221
CML:BSC BTS
Id:0900d805800d4446
BTS
The BTS object locates a cell connected to BSC. It logically represents all the
information related to the cell and to its configuration.
CREATE BTS
CREATE BTS NAME=BTSM:0..199/BTS:0..23 ,CELLGLID= ,BSIC=
[,PLMNP=] [,CELLRESH=] [,MSTXPMAXGSM=] [,MSTXP-
MAXDCS=] [,MSTXPMAXPCS=] [,RXLEVAMI=]
[,RDLNKTO=] [,RACHBT=] [,RACHLAS=] [,TCCCHLDI=]
[,PCCCHLDI=] [,FACCHQ=] ,CELLTYP= ,SYSID= ,BCCH-
FREQ= [,CALLF<nn>=] [,CCALL=] [,CRESPARI=]
[,CRESOFF=] [,TEMPOFF=] [,PENTIME=] [,CBQ=] [,NMUL-
BAC=] [,CONCELL=] [,BTSHSCSD=] [,MAXRETR=]
[,NSLOTST=] [,NY1=] [,NBLKACGR=] [,NFRAMEPG=]
[,MSTXPMAXCH=] [,PWROFS=] [,ASCISER=] [,NOCHF-
BLK=] [,NOCHBLKN=] [,INTCLASS=] [,INTAVEPR=]
[,RFRSINDP=] [,CELLBARR=] [,CREALL=] [,NALLWACC=]
[,EC=] [,SMSCBUSE=] [,DTXDLFR=] [,DTXDLHR=]
[,DTXUL=] [,IMSIATDT=] [,HOPP=] [,T3212=] [,PWROUT=]
[,DIRTCHASS=] [,BMONTH=] [,BSMONTH=] [,EARCLM=]
[,HOPMODE=] [,EXCDIST=] [,EEXCDIST=] [,EQ=]
[,QLPUB=] [,EPRE=] [,T200=] [,T3101=] [,T3105=] [,T3109=]
[,T3111=] [,TSYNC=] [,TSYNCUL=] [,TSYNCDL=]
[,TSYNCR=] [,TTRAU=] [,ENANCD=] [,NCDP1=] [,NCDP2=]
[,TGRANT=] [,NRPGRANT=] [,VGRULF=] [,TNOCH=]
[,EHRACT=] [,HRACTT1=] [,HRACTT2=] [,SDCCHCON-
GTH=] [,ASCIULR=] [,TUPLREP=] [,EEOTD=]
[,AMRFRC1=] [,AMRFRTH12=] [,AMRFRC2=]
[,AMRFRTH23=] [,AMRFRC3=] [,AMRFRTH34=]
[,AMRFRC4=] [,AMRHRC1=] [,AMRHRTH12=]
[,AMRHRC2=] [,AMRHRTH23=] [,AMRHRC3=]
[,AMRHRTH34=] [,AMRHRC4=] [,AMRFRIC=]
[,AMRHRIC=] [,AMRLKAT=] [,FHAMRFRC1=]
[,FHAMRFRTH12=] [,FHAMRFRC2=] [,FHAMRFRTH23=]
[,FHAMRFRC3=] [,FHAMRFRTH34=] [,FHAMRFRC4=]
[,FHAMRHRC1=] [,FHAMRHRTH12=] [,FHAMRHRC2=]
[,FHAMRHRTH23=] [,FHAMRHRC3=] [,FHAMRHRTH34=]
[,FHAMRHRC4=] [,FHAMRFRIC=] [,FHAMRHRIC=]
[,QSRHI=] [,FDDQMI=] [,FDDQO=] [,QSRHCINI=]
[,FDDREPQTY=] [,FDDMURREP=] [,UMTSSRHPRI=]
[,EANTHOP=] [,ANTHOPMOD=] [,ANTHOPP=] [,GUARM-
ABIS=] [,QSRHC=] [,TDDQO=] [,TDDMURREP=] [,REP-
TYP=] [,ETXDIVTS=] [,TXDIVTSEXCPT=] [,TXDIVTSPAR=]
[,TAADJ=] [,LCBM<n>=] [,EHRACTAMR=]


222 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS CREATE BTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of a cell specifying global parameters necessary
for the creation. The attributes within this object describe the basic properties of a BTS
which are not related to the Common Control Channels.
All the other parameters will assume their default values if no other command is submit-
ted. Moreover, this command implicitly creates the PWRC and HAND Managed Objects.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
PLMNP plmnPermitted
CELLRESH cellReselectHysteresis
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
RXLEVAMI rxLevAccessMin
RDLNKTO radioLinkTimeout
RACHBT rachBusyThreshold
RACHLAS rachLoadAveragingSlots
TCCCHLDI thresholdCcchLoadIndication
CREATE BTS [,HRACTAMRT1=] [,HRACTAMRT2=] [,FRACTTH1=]
[,FRACTTH2=] [,FRACTAMRTH1=] [,FRACTAMRTH2=]
[,EPAT1=] [,EPAT2=] [,ENDMA=] [,EAC=] [,ACFERMAX=]
[,ACBQPMAX=] [,ACPER=] [,ACLNKTYP=] [,ACBQPFF=]
[,ACEFLFF=] [,ACMINEFLDMA=] [,ACMAXEFLDMA=]
[,FRANOFFS=] [,BURNOFFS=] [,ENPERNOTDE=] [,PNO-
FACCH=] [,EHDCTR=] [,MEAEXTBCCH=] [,SLLPRM=]
[,CRTSWSPELLPRM=] [,AMRFRLLPRM=] [,AMRHRLL-
PRM=] [,CRTSWDLLPRM=] [,HSCSDLLPRM=] [,GLL-
PRM=] [,ELLPRM=] [,ASCILLPRM=]
[,CRTSWSPELLCOM=] [,AMRFRLLCOM=] [,AMRHR-
LLCOM=] [,CRTSWDLLCOM=] [,HSCSDLLCOM=]
[,GLLCOM=] [,ELLCOM=] [,DGRSTRGY=] [,LWWPSPRI=]
[,WPSPREF=] [,QLWPS=] [,GEXTS=] [,CSCE=]
[,CUCONF=] [,EFCRESEL=] [,FDDRSCPMI=] [,FDDQ-
MIO=] [,FDDREPTH=] [,FDDREPO=] [,TDDREPTH=]
[,TDDREPO=] [,FDDREPTH2=];


A30808-X3247-M230-6-7619

223
CML:BSC BTS
Id:0900d805800d4446
PCCCHLDI periodCcchLoadIndication
FACCHQ facchQual
CELLTYP cellType
SYSID systemIndicator
BCCHFREQ bcchFrequency
CALLF<nn> cellAllocationF<nn>
CCALL commonCellAllocation
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
NMULBAC nMultibandcell
CONCELL concentricCell
BTSHSCSD btsHSCSD
MAXRETR maxNumberRetransmission
NSLOTST numberOfSlotSpreadTrans
NY1 ny1
NBLKACGR noOfBlocksForAccessGrant
NFRAMEPG noOfMultiFramesBetweenPaging
MSTXPMAXCH msTxPwrMaxCcch
PWROFS powerOffset
ASCISER advancedSpeechCallItemsService
NOCHFBLK notificationChannelFirstBlock
NOCHBLKN notificationChannelBlockNumber
INTCLASS enableInterferenceClass
INTAVEPR interferenceAveragingProcess
RFRSINDP rfResourceIndicationPeriod
CELLBARR cellBarred
CREALL callReestablishmentAllowed
NALLWACC notAllowedAccessClasses
EC emergencyCall
SMSCBUSE smsCBUsed
DTXDLFR dTxDownLinkFullRate
DTXDLHR dTxDownLinkHalfRate
DTXUL dTxUplink
IMSIATDT allowImsiAttachDetach
HOPP enableHopping
T3212 btsTimer3212


224 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
PWROUT powerOutputThresholds
DIRTCHASS directTchAssignment
BMONTH bintChanMonitorThresholds
BSMONTH bintSignChanMonitorThresholds
EARCLM enableEarlyClassmark
HOPMODE hoppingMode
EXCDIST excessiveDistance
EEXCDIST enableExcessiveDistance
EQ enableQueuing
QLPUB queuingLengthPublic
EPRE enablePreemption
T200 t200
T3101 btsTimer3101
T3105 btsTimer3105
T3109 btsTimer3109
T3111 btsTimer3111
TSYNC tSync
TSYNCUL tSynchronizationUplink
TSYNCDL tSynchronizationDownlink
TSYNCR tSynchronizationR
TTRAU tTrau
ENANCD enableNoCallDetection
NCDP1 noCallDetectionPeriod1
NCDP2 noCallDetectionPeriod2
TGRANT timerGrant
NRPGRANT numberRepetitionGrant
VGRULF voiceGroupUplinkFree
TNOCH timerNotificationChannel
EHRACT enableHrActivation
HRACTT1 hRActivationThreshold1
HRACTT2 hRActivationThreshold2
SDCCHCONGTH sdcchCongestionThreshold
ASCIULR asciUplinkReply
TUPLREP timerUplinkReply
EEOTD enableEOTD
AMRFRC1 aMRFullRateCodec1
AMRFRTH12 aMRFullRateThresholds12
AMRFRC2 aMRFullRateCodec2
AMRFRTH23 aMRFullRateThresholds23


A30808-X3247-M230-6-7619

225
CML:BSC BTS
Id:0900d805800d4446
AMRFRC3 aMRFullRateCodec3
AMRFRTH34 aMRFullRateThresholds34
AMRFRC4 aMRFullRateCodec4
AMRHRC1 aMRHalfRateCodec1
AMRHRTH12 aMRHalfRateThresholds12
AMRHRC2 aMRHalfRateCodec2
AMRHRTH23 aMRHalfRateThresholds23
AMRHRC3 aMRHalfRateCodec3
AMRHRTH34 aMRHalfRateThresholds34
AMRHRC4 aMRHalfRateCodec4
AMRFRIC aMRFullRateInitialCodec
AMRHRIC aMRHRInitialCodec
AMRLKAT aMRLinkAdapTuning
FHAMRFRC1 fhAMRFullRateCodec1
FHAMRFRTH12 fhAMRFullRateThresholds12
FHAMRFRC2 fhAMRFullRateCodec2
FHAMRFRTH23 fhAMRFullRateThresholds23
FHAMRFRC3 fhAMRFullRateCodec3
FHAMRFRTH34 fhAMRFullRateThresholds34
FHAMRFRC4 fhAMRFullRateCodec4
FHAMRHRC1 fhAMRHalfRateCodec1
FHAMRHRTH12 fhAMRHalfRateThresholds12
FHAMRHRC2 fhAMRHalfRateCodec2
FHAMRHRTH23 fhAMRHalfRateThresholds23
FHAMRHRC3 fhAMRHalfRateCodec3
FHAMRHRTH34 fhAMRHalfRateThresholds34
FHAMRHRC4 fhAMRHalfRateCodec4
FHAMRFRIC fhAMRFullRateInitialCodec
FHAMRHRIC fhAMRHRInitialCodec
QSRHI qSearchI
FDDQMI fddQMin
FDDQO fddQOffset
QSRHCINI qSearchCinitial
FDDREPQTY fddReportingQuantity
FDDMURREP fddMultiratReporting
UMTSSRHPRI umtsSearchPriority
EANTHOP enableAntennaHopping
ANTHOPMOD antennaHoppingMode
ANTHOPP antennaHoppingPeriod


226 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
GUARMABIS guaranteedMinimumAbis
QSRHC qSearchC
TDDQO tddQOffset
TDDMURREP tddMultiratReporting
REPTYP reportType
ETXDIVTS enableTxDivTimeShift
TXDIVTSEXCPT txDivTimeShiftExcept
TXDIVTSPAR txDivTimeShiftParam
TAADJ taAdjust
LCBM<n> localCellBroadcastMessage<n>
EHRACTAMR enableHRActivationAmr
HRACTAMRT1 hRActivationAmrThreshold1
HRACTAMRT2 hRActivationAmrThreshold2
FRACTTH1 fullRateActivationThreshold1
FRACTTH2 fullRateActivationThreshold2
FRACTAMRTH1 fullRateActivationAMRThreshold1
FRACTAMRTH2 fullRateActivationAMRThreshold2
EPAT1 enhancedPairingThreshold1
EPAT2 enhancedPairingThreshold2
ENDMA enableDMA
EAC enableAc
ACFERMAX acFERMax
ACBQPMAX acBQPMax
ACPER acPeriod
ACLNKTYP acLinkType
ACBQPFF acBQPFgtFac
ACEFLFF acEFLFgtFac
ACMINEFLDMA acMinEFLDMA
ACMAXEFLDMA acMaxEFLDMA
FRANOFFS frameNumberOffset
BURNOFFS burstNumberOffset
ENPERNOTDE enablePeriodicalNotifDedicatedChan
PNOFACCH periodNotificationFACCH
EHDCTR enableHistoryOnDroppedCallTrace
MEAEXTBCCH measureExtraBCCH
SLLPRM signallingLayerListPrimary
CRTSWSPELLPRM circuitSwitchedSpeechLayerListPrimary
AMRFRLLPRM aMRFullRateLayerListPrimary
AMRHRLLPRM aMRHalfRateLayerListPrimary


A30808-X3247-M230-6-7619

227
CML:BSC BTS
Id:0900d805800d4446
CRTSWDLLPRM circuitSwitchedDataLayerListPrimary
HSCSDLLPRM hscsdLayerListPrimary
GLLPRM gprsLayerListPrimary
ELLPRM edgeLayerListPrimary
ASCILLPRM asciLayerListPrimary
CRTSWSPELLCOM circuitSwitchedSpeechLLComp
AMRFRLLCOM aMRFullRateLayerListComplementary
AMRHRLLCOM aMRHalfRateLayerListComplementary
CRTSWDLLCOM circuitSwitchedDataLayerListComp
HSCSDLLCOM hscsLayerListComplementary
GLLCOM gprsLayerListComplementary
ELLCOM edgeLayerListComplementary
DGRSTRGY downgradeStrategy
LWWPSPRI lowestWPSPriority
WPSPREF wPSPreference
QLWPS queuingLengthWPS
GEXTS gprsExtension
CSCE cellScenario
CUCONF carrierUnitConfiguration
EFCRESEL enableFastCellReselection
FDDRSCPMI fddRscpMin
FDDQMIO fddQMinOffset
FDDREPTH fddReportThreshold
FDDREPO fddReportOffset
TDDREPTH tddReportThreshold
TDDREPO tddReportOffset
FDDREPTH2 fddReportThreshold2
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Successful
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order
to perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTSM instance must be already equipped.


228 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
The object CBTS must be equipped to set attribute CCALL dif-
ferent by NULL.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set. For more
details see Application Guidelines n. 3, n. 8, n. 11, n. 12, n. 13,
n. 16, n. 20, n. 24, n. 26, n. 30, n. 31, n. 34, n. 42, n. 49, n. 50.
No more than 20 different combinations of (MCC-MNC-LAC)
are permitted inside BSC.
On BTS creation, the SLL attributes cannot be different from
NULL.
In order to set the flag ASCISER to TRUE, the ASCILLPRM
attribute must contain at least LY0 (in first position).
The flag BTSHSCSD cannot be TRUE if both HSCSDLLPRM
and HSCSDLLCOM are set to NULL.
In order to enable DIRTCHASS, the layers of service SLLPRM
must go from more to less shared.
The attibute DGRSTRGY cannot be set to
HSCSD_FIRST_DOWNGRADE or
DOWNGRADE_HSCSD_ONLY if the attribute MADGRLV
(BSC object) is set to 0.
The attribute EAC can be set to TRUE only if ENDMA of BTS
and CBTS objects are set to TRUE.
The attributes FRANOFFS and BURNOFFS cannot be set if
"Inter-Site Synchronization" is enabled.
With attribute HOSYNC equal SYNC (BSC object), the value of
BURNOFFS must be equal to the value of other cells of site.
The value DBSTDCELL for the CELLTYP attribute is not
accepted if the CONCELL parameter is set at TRUE.
The GEXTS attribute can assume value ALL900 on a BTS with
SYSID GSMDCS if BCCHFREQ isn't in the range (512-885).
The GEXTS can be set to ALLFREQ only if CELLTYP is set to
DBSTDCELL.
The GEXTS can be set to ALL900 only if SYSID is EXT900 or
GSMDCS.
For SYSID different by EXT900, GSMDCS, GSM850DCS and
GSM850PCS the only GEXTS value permitted is NULL.
The GEXTS attribute must be set to NULL if SYSID is EXT900
and BCCH is the extended band.
If GEXTS attribute is different by NULL, SYSID equal EXT900
or GSMDCS and BCCH in the range (1-124), the channels
SDCCH, SCBCH and TCHSD with pool type SDCCH or TCHSD
cannot be hopp.


A30808-X3247-M230-6-7619

229
CML:BSC BTS
Id:0900d805800d4446
When QLWPS assumes value 0, the attribute LWWPSPRI must
be NULL, while if QLPWPS assumes a values between 1..100
the attribute LWWPSPRI mus assume a value between 1..10.
REPTYP attribute must be activated to have ACLNKTYP differ-
ent by UL_SAMPLE_ONLY.
In case of Base Band Hopping you cannot have CCALL different
by NULL value.
In order to set the CUCONF parameter the BTS must be locked.
UNSUCCESSFUL_CELL_GLOB_ID
All the fields of cellGlobalIdentity must be set in the following
combination: MCC, MNC, LAC, CI, where:
Location Area Identity (LAI) = MCC + MNC + LAC;
Cell Global Identity = LAI + CI.
The CELLGLID cannot be equal to the CELLGLID assigned to
another BTS or TGTBTS,
The EHDCTR attribute can be set to TRUE only for BTS objects
belonging to BTSM objects having BR8.0 software version.
UNSUCCESSFUL_EQUAL_FREQ
Frequencies set at the CALLF<nn> (cellAllocationF<nn>)
attribute can not be equal; each frequency of CALLF attribute
must be different from BCCH frequency value and from frequen-
cies referenced by CCALL attribute.
Frequencies set at the CCALL cannot be equal.
WRONG_SYSID
Make reference to Application Guidelines n. 4, n. 44, n. 45.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE
Make reference to Application Guidelines n. 5.
The frequencies present into CCALL must be compatible with
SYSID of the cell.
The frequencies present into CCALL must be belong to CBTS.
If BCCHFREQ attribute is in the range (0. 301-424, 975-1023)
the CALLFx cannot be set to a frequency (1-124).
With SYSID attribute of BTS is EXT900 or GSMDCS, the BCCH
band cannot change from P to G1_GSM band and viceversa.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
One or more variables have been incorrectly set. For more
details see Application Guidelines n. 6, n. 14, n. 15, n. 18, n. 19,
n. 23, n. 33, n. 35, n. 36, n. 37, n. 43.


230 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
In the attribute WPSPREF, if the subfield numberWPS assumes
value 2, the minimum value of the subfield counterCycle must
be at least 3, while if numberWPS is set to 3, the counterCycle
must be at least 4.
INVALID_SVR
BS-242 cannot support GSMR as SYSID (BTS object).
BS-242 cannot support extended and concentric cells.
BS-242 cannot support base band hopping (HOPMODE of BTS
object).
The AMRHRCi/FHAMRHRCi attribute can not be set at value
RATE_05 (7.40 kbit/s) if the SW version running on the super-
ordinate BTSM belongs to BR6.0 release (see EXPSWV
parameter description).
The attributes EAC, ACFERMAX, ACBQPMAX, ACPER,
ACLNKTYP, ACBQPFF, ACEFLFF, ACMINEFLDMA and
ACMAXEFLDMA must assume a value different by NULL for
SW_ver greater or equal than BR8.0 and HW_ver equal to
BTS_plus or BS240 XS, and viceversa.
With HW version different by BTSplus or BS 240 XS the
attributes FRANOFFS and BURNOFFS cannot be set.
INVALID_COMMAND
The frequency hopping can be enabled only if there are some
CHANs using a frequency hopping law different from 0.
UNSUCCESSFUL_CBCH_NOTEQUIPPED
To set SMSCBUSE at TRUE it is required that CBCH channel is
already created, by setting either to BCBCH or SCBCH the
CHTYPE attribute of the CHAN object. Before deletion of a
created CBCH, SMSCBUSE has to be set at FALSE.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
Make reference to Application Guidelines n. 21, n. 22, n. 25.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The attribute HOPMODE (hoppingMode) can be set only if there
are no subordinate frequency hopping systems equipped.
HSCSD_TSC_INCONSISTENT
If the HSCSD service is activated at BTS side (i.e. attribute
BTSHSCSD of BTS set at TRUE) the HOPMODE can be set
from BBHOP to SYNHOP only if in the cell the single TCHs on
radio timeslot 0 have the same TSC of all the other single TCHs
belonging to the superordinated TRX.
UNSUCCESSFUL_MIXED_CELL_NOT_CONCENTRIC_CELL
If the SYSID parameter equals either to GSMDCS,
GSM850PCS or GSM850DCS the CONCELL parameter must
be set at TRUE only for standard cells.


A30808-X3247-M230-6-7619

231
CML:BSC BTS
Id:0900d805800d4446
INVALID_RATE
Make reference to Application Guidelines n. 35, n. 38, n. 39, n.
40, n. 41, n. 51.
INCOMP_NESWLOAD_VS_MESSAGE
The EANTHOP, ANTHOPMOD and ANTHOPP parameters
cannot be set at NULL value if the RR sub-field of the EXPSWV
parameter (see the parameter description) of the superordinate
BTSM object is equal or greater than 15.
The EANTHOP, ANTHOPMOD and ANTHOPP parameters
must be set at NULL value if the RR sub-field of the EXPSWV
parameter (see the parameter description) of the superordinate
BTSM object is less than 15.
The EANTHOP, ANTHOPMOD and ANTHOPP attributes are
supported only by BS-240, BS-240XS and BS-82.
The ETXDIVTS can not be set at TRUE if the SW version
running on the superordinate BTSM belongs to BR6.0 release
(see EXPSWV parameter description).
The ETXDIVTS can not be set at TRUE if the superordinate
BTSM is of type BS-20, BS-21, BS-22, BS-60, BS-61, BS-82,
BS-242.
The GUARMABIS attribute must have NULL value if the SW
Version running on the superordinate BTSM belongs to BR6.0
release (see EXPSWV parameter description).
The GUARMABIS attribute cannot be set at NULL value if the
SW Version running on the superordinate BTSM belongs to
BR7.0 release (see EXPSWV parameter description).
The REPTYP attribute can be set at ENHANCED value only if
the SW Version running on the superordinate BTSM belongs to
BR7.0 release (see EXPSWV parameter description).
The TAADJ attribute must have NULL value if the SW Version
running on the superordinate BTSM belongs to BR6.0 release
(see EXPSWV parameter description).
The TAADJ attribute cannot be set at NULL value if the SW
Version running on the superordinate BTSM belongs to BR7.0
release (see EXPSWV parameter description).
If the superordinate BTSM SW is less than BR8.0, ENPER-
NOTDE and PNOFACCH attributes must assume the NULL
value.
The ENPERNOTDE and PNOFACCH attributes cannot be set
to NULL, if the superordinate BTSM SW is greater or equal than
BR8.0.
The MEAEXTBCCH attribute can be set to TRUE only if the
superordinate BTSM has a SW Version >=8.0.


232 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
The attributes FRANOFFS and BURNOFFS cannot assume
value different by NULL for SW version less than BR8.0, and
viceversa.
The CELLTYP attribute can assume DBSTDCELL value if the
SW version running on the superordinate BTSM object belongs
to BR8.0 release.
For CUCONF parameter values different from the default
(homogeneous) are allowed only for BTSplus mainline (hh=04,
ii=01) and BS240XS (hh=04, ii=06).
UNSUCCESSFUL_INVALID_BCCH_FREQUENCY
In GSMDCS/GSM850DCS cells: the band of BCCH frequency
cannot be changed.
UNSUCCESSFUL_FREQUENCY_CHANGE_NOT_ALLOWED
In a GSMDCS/GSM850DCS mixed cell it is not possible to
change a frequency value from one band of the cell to another
if the frequency is already assigned to a TRX; this is due to the
fact that the hardware of a TRX is not able to manage two differ-
ent frequency bands.
UNSUCCESSFUL_OVERLAP_BAND
In GSMDCS/GSM850DCS and EXT900 cells, if the frequencies
change, the involved MOBALLOC frequencies must remain in
the same sub-band.
NO_MORE_FREQ_AVAILABLE
The maximum number of frequencies that can be assigned to a
cell has been reached. Make reference to Application Guideline
n. 32.
The sum of frequencies in a cell is major of 64.
DMA_NOT_SUPPORTED
The attribute ENDMA cannot be set to TRUE in the Create
command.
INVALID_NETWORK_IDENTIFIER
The attribute CELLTYP cannot assume value DBSTDCELL with
SYSID different by GSMDCS, GSM850DCS and GSM850PCS.


A30808-X3247-M230-6-7619

233
CML:BSC BTS
Id:0900d805800d4446
Application Guidelines:
1. The management of the BTS managed object is split into the management of five
attribute groups:
2. The creation of a BTS implies the implicit creation of the HAND and PWRC
Managed Objects.
3. Three attributes in the BTS Managed Object are formatted in digits; the attributes
are:
the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained
in the CellGlobalId (CELLGLID);
the bSIdentityCode (BSIC);
4. The SYSID parameter can assume 10 values:
BASIC BTS basic group
CCCH BTS CCCH configuration group
INTERF BTS interference level meas group
OPTIONS BTS options group
TIMER BTS timer group
CELLGLID = MCC-MNC-LAC-CI
Note that
MCC = D1D2D3
MNC = D1D2D3
Dx means digit (only numerical characters shall be used; for numbers
from 0 to 9 it must be entered one digit). In fact 9 is different from 09.
For MCC all digits are mandatory while for MNC D1 and D2 are
mandatory.
BSIC = D1D2
Dx means digit (only numerical characters 0..7 shall be used)
Note that D1 is the NetworkColourCode (NCC) and D2 is the
BTSColourCode (BCC)
This attributes are stored in the system in their decimal
representation (which is the input format) but it is necessary to
check the range of each digit:
MCC, MNC 0 =< Dx =< 9
BSIC 0 =< Dx =< 7
Do not configure cells without giving a value to the parameter Cell
Identifier (CI) of the Cell Global Identifier attribute belonging to the
BTS BASICS group because such cells are not handled by the
system.


234 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
BB900 (GSM Standard Band);
EXT900 (GSM Mixed Band)
GSMR (Railway Band)
PCS1900
DCS1800
GSMDCS
GSM850
GSM850PCS
GSM850DCS
If the NETWTYPE parameter (previously set by the SET BSC command) is
GSMDCS then only the BB900, EXT900, DCS1800 and GSMDCS values are per-
mitted to the SYSID.
If the NETWTYPE parameter is GSMR then only the GSMR value is permitted to the
SYSID.
If the NETWTYPE parameter is GSMPCS then only the BB900, EXT900 and
PCS1900 values are permitted to the SYSID.
If the NETWTYPE parameter is GSM850PCS then only GSM850, GSM850PCS and
PCS1900 values are permitted to the SYSID.
If the NETWTYPE parameter (previously set by the SET BSC command) is
GSM850DCS then only GSM850, GSM850DCS and DCS1800 values are permitted
to the SYSID.


A30808-X3247-M230-6-7619

235
CML:BSC BTS
Id:0900d805800d4446
5. The frequencies set to CALL (cellAllocation) attribute must follow these rules:
For the US market (PCS1900 and the PCM24) the following frequency blocks are
defined:
The following considerations are valid only for the US market, if SYSID = PCS1900:
all the frequencies of the CALLF (cellAllocation) must belong to one of the allowed
frequencies; in particular, the maximum RF output power for the corner frequencies
(512 and 810) is reduced of a fixed quantity, depending on the CU type. The table
below shows the amount of the reduction for different kinds of CUs.
if SYSID = BB900 then 1 =< frequency =< 124
if SYSID = EXT900 then 0 =< frequency =< 124
975 =< frequency =< 1023
if SYSID = DCS1800 then 512 =< frequency =< 885
if SYSID = GSMR then 955 =< frequency =< 974
if SYSID = PCS1900 then 512 =< frequency =< 810
if SYSID = GSMDCS then 0 = < frequency =< 124 and
975 = < frequency =< 1023 (GSM
extended band)
512 =< frequency =< 885 (DCS 1800)
If SYSID = GSM850 then 128 =< frequency =< 251
If SYSID = GSM850PCS then 128 =< frequency =< 251
512 =< frequency =< 810
If SYSID = GSM850DCS then 128 =< frequency =< 251 (GSM 850)
512 =< frequency =< 885 (DCS 1800)
from 512 to 585 for A block
from 587 to 610 for D block
from 612 to 685 for B block
from 687 to 710 for E block
from 712 to 735 for F block
from 737 to 810 for C block
CU type ARFCN 512 reduction ARFCN 810 reduction
ECUPHPV3 8 dB 6 dB
ECUPHPV4 8 dB 6 dB
ECUPV2 4 dB 2 dB
GCUPV1 4 dB 2 dB
CUPV4 4 dB 4 dB


236 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
6. For the different SYSID setting, the following "msTxPwrMax" parameters must be
used:
If SYSID equals BB900, EXT900, GSMDCS, GSMR, GSM850, GSM850PCS or
GSM850DCS the MSTXPMAXGSM must be set.
If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS
must be set.
If SYSID equals PCS1900 the MSTXPMAXPCS must be set.
If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSM must be set
at 2..15 (for the GSM part of the cell), and the MSTXPMAXDCS must be set at
0..15 (for the DCS part of the cell).
If SYSID equals GSM850PCS the MSTXPMAXGSM must be set at 2..15 (for the
GSM part of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31
(for the PCS part of the cell).
7. After the creation of the object, the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
8. If CRESPARI =0 --> CRESOFF, TEMPOFF, PENTIME, CBQ are skipped.
If CRESPARI =1 --> CRESOFF, TEMPOFF, PENTIME, CBQ are not skipped.
9. For frequencies of E-GSM no DUCOM may be used. No warning will be generated
in case of use of DUCOM with E-GSM frequencies.
10. A cell configured with 6 TRXs and served by FTNF must be alarm supervised by
ALCO of type Q300.
11. The value EXTCELL for the CELLTYP attribute is not accepted if the CONCELL
parameter is set at TRUE.
12. The HSCSD service can be activated in the cell (BTSHSCSD = TRUE) only if the
HSCSD service is activated at BSC side (ENHSCSD attribute of BSC set at TRUE).
13. In a GSMPCS network two BTS belonging to the same BTSM cannot have mixed
GSM-PCS SYSID values.
14. If the BTS is a BS-82, it is not possible to create a BTS number for each BTSM
greater than 8.
15. If the SCBCH channel type is configured (see CHAN object) then the NBLKACGR
attribute must not be equal to 0.
16. To enable ASCISER, the NBLKACGR must be greater than NOCHBLKN. It is
possible to enable ASCISER following the indications described in the next table:
In case of not created channel please refer to MAINBCCH channel type case.
NOCHFBLK NOCHBLKN Channel Type (CHTYPE)
1..4 1..4
5 1..3 MAINBCCH
6 1..2
7 1
1..3 1 MBCCHC or BCBCH


A30808-X3247-M230-6-7619

237
CML:BSC BTS
Id:0900d805800d4446
17. When Abis satellite links are used, due to introduction of additional delays between
MS channel requests and BSC immediate assignment commands, the probability of
repeated requests from MS is increased depending on the value of the parameter
NSLOTST.
The NSLOTST value corresponding to a max waiting time before retransmission of
the CHANNEL REQUEST is recommended. Additional SDCCHs are recommended
to prevent congestion due to retransmission.
18. When the interference classification of idle traffic channels is enabled (INTCLASS
attribute) the following attributes are relevant:
The values of the interference boundaries are strictly increasing (00 <= x1 < x2 < x3
< x4 < 63, where xn = intThrBoun).
x1, x2, x3 and x4 constitute the right boundaries of the interference bands they
belong to.
Example:
x1 = 00 dBr (<= -110 dBm):
x2, x3, x4 have fixed values as follows:
x2 = 03 dBr (<= -107 dBm)
x3 = 61 dBr (<= -49 dBm)
x4 = 62 dBr (<= -48 dBm)
interference band 1 (dBm): -..<= -110
interference band 2 (dBm): -110 <...<= -107
interference band 3 (dBm): -107 <...<= -49
interference band 4 (dBm): -49 <...<= -48
interference band 5 (dBm): -48 <...<= +
All boundaries are coded as binary presentation of -X dBm decimal values.
For the values make reference to Appendix B: Group 2.
19. For the attributes BMONTH and BSMONTH the following relationship must be sat-
isfied for the fields minor, major, critical:
minor < major < critical.
20. For the attributes BMONTH and BSMONTH, regarding the flags minor, major,
critical and the relative threshold attributes, note that:
if the flags are set at ENABLE the threshold values cannot be skipped;
if the flags are set at DISABLE the threshold values must be skipped;
if the flags are skipped also the threshold values must be skipped.
21. The frequency hopping can be enabled only if there are no channel instances with
the same time slot using two different frequency hopping systems with the same
common frequency.
averagingPeriod INTAVEPR
interferenceThresholdBoundaries INTAVEPR
rfResourceIndicationPeriod RFRSINDP


238 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
22. The frequency hopping can be enabled only if the frequency belonging to a
superordinate TRX of a non-hopping channel is not used in a frequency hopping
system assigned to a hopping channel instance with the same timeslot number.
23. In case of Standard and Dual Band Standard (Not Extended) Cell, the value of the
attribute EXCDIST must be in range 1..35 km.
24. If the excessive distance is enabled (EEXCDIST = TRUE) the following attribute is
relevant:
excessiveDistance - EXCDIST attribute of HAND object.
The value assigned to the attribute EXCDIST must be greater than the value
assigned to the distance handover thresholds:
hoThresholdMsRangeMax - attribute HOTMSRM of HAND object (in case of
standard cell and Dual Band Standard cell);
hoThresholdMsRangeMax - attribute HOTMSRME of HAND object (in case of
extended cell).
25. The extended channels use two consecutive timeslots: therefore, in case of
extended cell, all the previous Application Guidelines regarding frequency hopping
consistency apply also to the timeslot following the channel timeslot.
26. In order to enable the HSCSD service, the EARCLM attribute must be previously set
at TRUE.
27. If EPRE parameter is set at TRUE value the timer BSCT7 of the BSC object must
be set at a value between 6 and 254.
28. Within GSM Rec. 04.08, timer T3107 is specified for supervision of receipt of
handover complete response assignment complete. In addition two timers with the
same task are specified for BSSMAP, namely BSCT8 and BSCT10 (see BSC
object). To make easier the handling of these timers only two of them are used within
SBS. There is no lack in supervision of above named messages due to this imple-
mentation, neither for internal nor for external handover procedures.
29. The timers TSYNC and TTRAU must be set longer than ALARMT2 (see LICD
object). The timers TSYNC and TTRAU must be set longer than BSCT10 (BSC
object) and BSCT8 (BSC object). This is to ensure that a signalling failure (BSCT8
and BSCT10) is detected before a transcoder failure (TSYNC and TTRAU).
The attribute TSYNC should be equal to TTRAU attribute.
30. For the attribute NCDP2, the TimerNoCall2 field can be set only if the StarTime2
field is different from NOTUSED.
31. If the second time-frame is configured by the NCDP2 setting, the StartTime2 value
must be greater than the StartTime1 field of NCDP1 attribute.
If the second time-frame is configured by the NCDP2 setting, the following configu-
ration rule must be satisfied:
a whole observation period must be present within each time-frame,
i.e. TimerNoCall1 <= 6*(StartTime2 - StartTime1)
TimerNoCall2 <= 6*((24 - (StartTime2 - StartTime1))
The two time-frames must be converted in periods of ten minutes.


A30808-X3247-M230-6-7619

239
CML:BSC BTS
Id:0900d805800d4446
32. The maximum number of frequencies that can be assigned to a cell depends on the
delta between the lowest and the highest frequency given to the CALLFn and
CCALL attributes, as shown in the following table.
33. The ASCIULR attribute cannot be set at VBSENABLE, VGCSENABLE or
VBC_VGCSENABLE if the ASCISER attribute is set at ASCI_DISABLED.
34. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS, MSTXPMAXPCS can
be set only if the SYSID refers to the corresponding band; otherwise they must be
skipped or assume the value <NULL>.
35. It is not possible to set all AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi)
attributes at NULL; at least one value must be configured.
36. The following relations between the Threshold (TH) and Hysteresis (HYS) fields of
two adjacent Codecs must be satisfied when the value of the AMRFRCi/FHAMR-
FRCi (AMRHRCi/FHAMRHRCi) attribute is changed:
TH(i-1) <= TH(i) <= TH(i+1) i = 2,3
(TH + HYS)(i-1) <= (TH + HYS)(i) <= (TH + HYS)(i+1)
37. The AMRFRTHij/FHAMRFRTHij (AMRHRTHij/FHAMRHRTHij) attribute can be set
at NULL value only if AMRFRCj/FHAMRFRCj (AMRHRCj/FHAMRHRCj) attribute is
already set at NULL.
38. The value of the AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi) attribute must
be smaller than the value of the AMRFRCi+1/FHAMRFRCi+1 (AMRHRCi+1/FHAM-
RHRCi+1) attribute.
39. If the AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi) attribute is not configured,
also all the subsequent AMRFRCj/FHAMRFRCj (AMRHRCj/FHAMRHRCj)
attributes have not to be configured (j > i).
40. The AMRHRCi/FHAMRFRCi attribute can not be set at value RATE_04 or RATE_05
for BSs 2x/6x.
41. The AMRFRIC/FHAMRFRIC (AMRHRIC/FHAMRHRIC) attribute must not be equal
to CODEC_MODE_i value if the AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi)
attribute is set at NULL value.
42. The EANTHOP (enableAntennaHopping) attribute can be enabled only if the HOPP
(enableHopping) attribute is set at TRUE and the HOPMODE (hoppingMode) value
is different from BBHOP (baseband hopping).
43. If the BTS is a BS-240XS, it is not possible to create for each BTSM a BTS number
greater than 3.
N. max Freq. Delta
16 Any
17 Any, if frequency 0 is present
18 512
22 256
29 128
64 111 or frequency in BB900 band


240 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
44. If the BTS is a BS-240XS the SYSID cannot assume the values GSMDCS,
GSM850PCS or GSM850DCS.
45. All the subordinate to a BS-240XS must have the same frequency range, no mixed
configurations are allowed. The allowed configurations are:
BB900
EXT900
PCS1900
DCS1800
GSMR
GSM850.
46. If the cell load dependent activation of Half Rate channels is enabled (by means of
EHRACT parameter) in a cell configured as Extended or Concentric, the following
rule applies: if no channels have been configured as TCHF_HLF (see CHTYPE
parameter of CHAN object) in the Near/Inner area and a new request comes for an
Half Rate channel to be assigned into the Near/Inner area, the system first tries to
assign a Full Rate channel into this area. If there are no available channels into the
Near/Inner area, the system assigns a Full Rate channel into the Far/Complete area
(even though TCHF_HLF channels have been configured in the Far/Complete
area).
47. In case of request with channel rate Full the pre-emption (which is enabled by
means of EPRE parameter) is allowed only to vulnerable calls that are allocated on
Full Rate channels. No preemption of Half Rate calls is performed. This restriction
is due to impossibility, with actual implementation, to be sure that after pre-emption
procedure the other part of the channel is still available.
48. LCBMx attributes can be set at a value different from NULL only if no CBCL
instances have been already equipped.
49. The ETXDIVTS parameter can be set at TRUE only if (EANTHOP = FALSE and
HOPP = FALSE) or (HOPP = TRUE and HOPMODE = SYNHOP).
50. The sum of the GUARMABIS attributes for the BTSs belonging to the same BTSM
must be less or equal to 70.
51. The AMRHRCi/FHAMRHRCi attribute can be set at value RATE_05 (7.40 kbit/s)
only if the BTS HW version is BTSplus.
52. In order to avoid wrong parameter settings, it is required that:
fRActivationThreshold1 < hRActivationThreshold1
fRActivationThreshold2 < hRActivationThreshold2
fRActivationAMRThreshold1 < hRActivationThreshold1
fRActivationAMRThreshold2 < hRActivationthreshold2
The number of intracell handovers between AMRFR and AMRHR is decreased as
the configured hysteresis between hRActivationThresholdi and hRDecomprThresh-
oldi is increased.
Example of Command Execution:
Create BTS:NAME=BTSM:0/BTS:0,CELLGLID="123"-"456"-1-1,BSIC=1-2,
PLMNP=5,CELLRESH=5,MSTXPMAXGSM=5,MSTXPMAXDCS=<NULL>,


A30808-X3247-M230-6-7619

241
CML:BSC BTS
Id:0900d805800d4446
MSTXPMAXPCS=<NULL>,RXLEVAMI=5,RDLNKTO=5,RACHBT=5,
RACHLAS=102,TCCCHLDI=1,PCCCHLDI=255,FACCHQ=5,CELLTYP=STDCELL,
SYSID=BB900 ,BCCHFREQ=2,CALLF01=123,CRESPARI=1,CRESOFF=2, TEM-
POFF=1,PENTIME=2,CBQ=1,NMULBAC=1,CONCELL=FALSE,
BTSHSCSD=FALSE,EHRACT=TRUE,HRACTT1=10,
HRACTT2=12,SDCCHCONGTH=70,EEOTD=TRUE,AMRFRC1=RATE_01,
AMRFRTH12=7-2,AMRFRC2=RATE_03,AMRFRTH23=12-2,AMRFRC3=RATE_06,
AMRFRTH34=23-2,AMRFRC4=RATE_08,AMRHRC1=RATE_01,
AMRHRTH12=19-0,AMRHRC2=RATE_02,AMRHRTH23=24-0,
AMRHRC3=RATE_03,AMRHRTH34=26-0,AMRHRC4=RATE_04,
AMRFRIC=START_MODE_FR,AMRHRIC=START_MODE_HR,
AMRLKAT=100,QSRHI=OMDB78,FDDQMI=MDB17,FDDQO=DB12,
QSRHCINI=ALWAYS,FDDREPQTY=RSCP,FDDMURREP=2,UMTSSRHPRI=TRUE,
EANTHOP=FALSE,ANTHOPMOD=NOBCCHTRX,ANTHOPP=SECOND,
GUARMABIS=0,QSRHC=UMDB78, TDDQO=8, TDDMURREP=2, REPTYP=NOR-
MAL,ETXDIVTS=FALSE, TXDIVTSEXCPT=NONE, TXD-
VTSPAR=MDB1,TAADJ=1,LCBM0=NULL,LCBM1=NULL,LCBM2=NULL,LCBM3=NU
LL, HRACTAMRT1=6000,HRACTAMRT2=6000, EPAT1=6000, EPAT2=6000,
MAXRETR=One,NSLOTST=0,NY1=1,NBLKACGR=2,NFRAMEPG=2,
MSTXPMAXCH=0,PWROFS=0,ASCISER=ASCI_ENABLED, NOCHFBLK=1,
NOCHBLKN=1,ASCIULR=ULRDISABLE, INTCLASS=TRUE,
INTAVEPR=2-13-26-50-56,RFRSINDP=1,CELLBARR=FALSE,
CREALL=NOTALLOWED,NALLWACC=na0,EC=FALSE,SMSCBUSE=TRUE,
DTXDLFR=TRUE,DTXDLHR=TRUE,DTXUL=MAYFSHNH,IMSIATDT=FALSE,
HOPP=TRUE,T3212=0,PWROUT=m8db -m6db -db3,DIRTCHASS=FALSE,
BMONTH=Enabled(30)-Enabled(60)-Enabled(90),
BSMONTH=Disabled(0)Disabled(0)Disabled(0),EARCLM=TRUE,
HOPMODE=BBHOP,EXCDIST=1,EEXCDIST=FALSE,EQ=DIS-
ABLED,EPRE=ENABLED,T200=44-31-41-90-90-90-135,T3101=HLFSEC-
12,T3105=MS10-4,
T3109=HLFSEC-30,T3111=HLFSEC-3,TSYNC=200,TSYNCUL=10,TSYNCDL=10,
TSYNCR=200, TTRAU=200,ENANCD=DISABLED,NCDP1=H8-6,NCDP2=H21-30,
TGRANT=100, NRPGRANT=10,VGRULF=8,TNOCH=3,TUPLREP=5,
EHDCTR=FALSE, PNOFACCH=2.5, ENPERNOTDE=FALSE, ENDMA=FALSE,
CCALL=CCALLF01&CCALLF02&CCALLF03, FHAMRFRC1=RATE_01,
FHAMRFRC2=RATE_03, FHAMRFRC3=RATE_06, FHAMRFRC4=RATE_08,
FHAMRFRTH12=7-2, FHAMRFRTH23=12-2, FHAMRFRTH34=23-2,
FHAMRHRC1=RATE_01, FHAMRHRC2=RATE_02,
FHAMRHRC3=RATE_03,FHAMRHRC4=RATE_04, FHAMRHRTH12=12-0,
FHAMRHRTH23=24-0, FHAMRHRTH34=26-0, FHAMRFRIC=START_MODE_FR,
FHAMRHRIC=START_MODE_HR, EAC=FALSE, ACFERMAX=5.0, ACBQPMAX=5.0,
ACPER=SACCH_120, ACLNKTP=UL_AND_DL_SAMPLES_COMMONLY,
ACBQPFF=0.2, ACEFLFF=0.04, ACMINEFLDMA=PER_10, ACMAX-
ELDMA=PER_50,MEAEXTBCCH=TRUE,SLLPRM=LY0<NULL>, CRTSWSPELL-


242 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
PRM= <NULL>, AMRFRLLPRM=<NULL>, AMRHRLLPRMRM=<NULL>,
CRTSWDLLPRM=<NULL>, GLLPRM=<NULL>, ELLPRM=<NULL>, ASCIL-
LPRM=<NULL>, HSCSDLLPRM=<NULL>, CRTSWSPELLCOM=<NULL>, AMRFR-
LLCOM=<NULL>, AMRHRLLCOM=<NULL>, CRTSWDLLCOM=<NULL>,
GLLCOM=<NULL>, ELLCOM=<NULL>, HSCSDLLCOM=<NULL>, FRACTTH1=3000,
FRACTTH2=3000, FRACTAMRTH1=3000, FRACTAMRTH2=3000, EHRAC-
TAMR=TRUE, FRANOFFS=NULL, BURNOFFS=NULL, QLWPS=3, QLPUB=3,
LWWPSPRI=2, WPSPREF=2-1, GEXTS=NULL, CSCE=URBAN,
FDDREPTH=RXLEV_00, FDDREPO=DB00, TDDREPRH=RXLEV_00,
FDDREPO=DB00, FDDREPTH2=0, FDDRSCPMI=MDB101, CUCONF=homoge-
neous, EFCRESEL=FALSE, FDDQMIO=DB00;
DELETE BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS DELETE BTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created BTS.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DELETE BTS NAME=BTSM:0..199/BTS:0..23;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a BTS, the relative object instance must be in
LOCKED state.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
All the LAPDLR, ADJC, FHSY, PTPPKF, SCA, CTRSCHED
and RFLOOP object instances associated to the BTS object
instance must be previously deleted.


A30808-X3247-M230-6-7619

243
CML:BSC BTS
Id:0900d805800d4446
Application Guidelines:
None.
Example of Command Execution:
Delete BTS:NAME=BTSM:0/BTS:0;
The BTS object instance cannot be deleted if it is referenced
as the target cell by any ADJC object.
The QSMONBTS object instances associated to the BTS
object instance must be previously deleted.
COLOCATE_RELATIONSHIP_PRESENT
If the BTS is defined colocated to other BTSs of the BSC, all
the colocated relationships with other BTSs of the BSC have
to be removed before deleting the BTS.


244 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
GET BTS
GET BTS NAME=BTSM:0..199/BTS:0..23 [,REQATTL= CELLGLID
,BSIC ,PLMNP ,CELLRESH ,MSTXPMAXGSM ,MSTXP-
MAXDCS ,MSTXPMAXPCS ,RXLEVAMI ,RDLNKTO
,RACHBT ,RACHLAS ,TCCCHLDI ,PCCCHLDI ,FACCHQ
,CELLTYP ,SYSID ,BCCHFREQ ,CALLF<nn> ,CCALL
,CRESPARI ,CRESOFF ,TEMPOFF ,PENTIME ,CBQ
,NMULBAC ,CONCELL ,BTSHSCSD ,MAXRETR
,NSLOTST ,NY1 ,NBLKACGR ,NFRAMEPG ,MSTXP-
MAXCH ,PWROFS ,ASCISER ,NOCHFBLK ,NOCHBLKN
,INTCLASS ,INTAVEPR ,RFRSINDP ,CELLBARR ,CREALL
,NALLWACC ,EC ,SMSCBUSE ,DTXDLFR ,DTXDLHR
,DTXUL ,IMSIATDT ,HOPP ,T3212 ,PWROUT ,DIRT-
CHASS ,BMONTH ,BSMONTH ,EARCLM ,HOPMODE
,EXCDIST ,EEXCDIST ,EQ ,QLPUB ,EPRE ,T200 ,T3101
,T3105 ,T3107 ,T3109 ,T3111 ,TSYNC ,TSYNCUL
,TSYNCDL ,TSYNCR ,TTRAU ,ENANCD ,NCDP1 ,NCDP2
,TGRANT ,NRPGRANT ,VGRULF ,TNOCH ,EHRACT
,HRACTT1 ,HRACTT2 ,SDCCHCONGTH ,ASCIULR
,TUPLREP ,EEOTD ,AMRFRC1 ,AMRFRTH12 ,AMRFRC2
,AMRFRTH23 ,AMRFRC3 ,AMRFRTH34 ,AMRFRC4
,AMRHRC1 ,AMRHRTH12 ,AMRHRC2 ,AMRHRTH23
,AMRHRC3 ,AMRHRTH34 ,AMRHRC4 ,AMRFRIC
,AMRHRIC ,AMRLKAT ,FHAMRFRC1 ,FHAMRFRTH12
,FHAMRFRC2 ,FHAMRFRTH23 ,FHAMRFRC3
,FHAMRFRTH34 ,FHAMRFRC4 ,FHAMRHRC1
,FHAMRHRTH12 ,FHAMRHRC2 ,FHAMRHRTH23
,FHAMRHRC3 ,FHAMRHRTH34 ,FHAMRHRC4 ,FHAMR-
FRIC ,FHAMRHRIC ,QSRHI ,FDDQMI ,FDDQO ,QSRHCINI
,FDDREPQTY ,FDDMURREP ,UMTSSRHPRI ,EANTHOP
,ANTHOPMOD ,ANTHOPP ,GUARMABIS ,QSRHC
,TDDQO ,TDDMURREP ,REPTYP ,ETXDIVTS ,TXDIVT-
SEXCPT ,TXDIVTSPAR ,TAADJ ,LCBM<n> ,EHRACTAMR
,HRACTAMRT1 ,HRACTAMRT2 ,FRACTTH1 ,FRACTTH2
,FRACTAMRTH1 ,FRACTAMRTH2 ,EPAT1 ,EPAT2
,ENDMA ,EAC ,ACFERMAX ,ACBQPMAX ,ACPER
,ACLNKTYP ,ACBQPFF ,ACEFLFF ,ACMINEFLDMA
,ACMAXEFLDMA ,FRANOFFS ,BURNOFFS ,ENPER-
NOTDE ,PNOFACCH ,EHDCTR ,MEAEXTBCCH ,SLLPRM
,CRTSWSPELLPRM ,AMRFRLLPRM ,AMRHRLLPRM
,CRTSWDLLPRM ,HSCSDLLPRM ,GLLPRM ,ELLPRM
,ASCILLPRM ,CRTSWSPELLCOM ,AMRFRLLCOM
,AMRHRLLCOM ,CRTSWDLLCOM ,HSCSDLLCOM
,GLLCOM ,ELLCOM ,DGRSTRGY ,LWWPSPRI
,WPSPREF ,QLWPS ,GEXTS ,CSCE ,CUCONF ,EFCRE-
SEL ,FDDRSCPMI ,FDDQMIO ,FDDREPTH ,FDDREPO
,TDDREPTH ,TDDREPO ,FDDREPTH2];


A30808-X3247-M230-6-7619

245
CML:BSC BTS
Id:0900d805800d4446
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
PLMNP plmnPermitted
CELLRESH cellReselectHysteresis
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
RXLEVAMI rxLevAccessMin
RDLNKTO radioLinkTimeout
RACHBT rachBusyThreshold
RACHLAS rachLoadAveragingSlots
TCCCHLDI thresholdCcchLoadIndication
PCCCHLDI periodCcchLoadIndication
FACCHQ facchQual
CELLTYP cellType
SYSID systemIndicator
BCCHFREQ bcchFrequency
CALLF<nn> cellAllocationF<nn>
CCALL commonCellAllocation
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
NMULBAC nMultibandcell
CONCELL concentricCell
BTSHSCSD btsHSCSD
MAXRETR maxNumberRetransmission


246 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
NSLOTST numberOfSlotSpreadTrans
NY1 ny1
NBLKACGR noOfBlocksForAccessGrant
NFRAMEPG noOfMultiFramesBetweenPaging
MSTXPMAXCH msTxPwrMaxCcch
PWROFS powerOffset
ASCISER advancedSpeechCallItemsService
NOCHFBLK notificationChannelFirstBlock
NOCHBLKN notificationChannelBlockNumber
INTCLASS enableInterferenceClass
INTAVEPR interferenceAveragingProcess
RFRSINDP rfResourceIndicationPeriod
CELLBARR cellBarred
CREALL callReestablishmentAllowed
NALLWACC notAllowedAccessClasses
EC emergencyCall
SMSCBUSE smsCBUsed
DTXDLFR dTxDownLinkFullRate
DTXDLHR dTxDownLinkHalfRate
DTXUL dTxUplink
IMSIATDT allowImsiAttachDetach
HOPP enableHopping
T3212 btsTimer3212
PWROUT powerOutputThresholds
DIRTCHASS directTchAssignment
BMONTH bintChanMonitorThresholds
BSMONTH bintSignChanMonitorThresholds
EARCLM enableEarlyClassmark
HOPMODE hoppingMode
EXCDIST excessiveDistance
EEXCDIST enableExcessiveDistance
EQ enableQueuing
QLPUB queuingLengthPublic
EPRE enablePreemption
T200 t200
T3101 btsTimer3101
T3105 btsTimer3105
T3107 btsTimer3107
T3109 btsTimer3109


A30808-X3247-M230-6-7619

247
CML:BSC BTS
Id:0900d805800d4446
T3111 btsTimer3111
TSYNC tSync
TSYNCUL tSynchronizationUplink
TSYNCDL tSynchronizationDownlink
TSYNCR tSynchronizationR
TTRAU tTrau
ENANCD enableNoCallDetection
NCDP1 noCallDetectionPeriod1
NCDP2 noCallDetectionPeriod2
TGRANT timerGrant
NRPGRANT numberRepetitionGrant
VGRULF voiceGroupUplinkFree
TNOCH timerNotificationChannel
EHRACT enableHrActivation
HRACTT1 hRActivationThreshold1
HRACTT2 hRActivationThreshold2
SDCCHCONGTH sdcchCongestionThreshold
ASCIULR asciUplinkReply
TUPLREP timerUplinkReply
EEOTD enableEOTD
AMRFRC1 aMRFullRateCodec1
AMRFRTH12 aMRFullRateThresholds12
AMRFRC2 aMRFullRateCodec2
AMRFRTH23 aMRFullRateThresholds23
AMRFRC3 aMRFullRateCodec3
AMRFRTH34 aMRFullRateThresholds34
AMRFRC4 aMRFullRateCodec4
AMRHRC1 aMRHalfRateCodec1
AMRHRTH12 aMRHalfRateThresholds12
AMRHRC2 aMRHalfRateCodec2
AMRHRTH23 aMRHalfRateThresholds23
AMRHRC3 aMRHalfRateCodec3
AMRHRTH34 aMRHalfRateThresholds34
AMRHRC4 aMRHalfRateCodec4
AMRFRIC aMRFullRateInitialCodec
AMRHRIC aMRHRInitialCodec
AMRLKAT aMRLinkAdapTuning
FHAMRFRC1 fhAMRFullRateCodec1
FHAMRFRTH12 fhAMRFullRateThresholds12


248 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
FHAMRFRC2 fhAMRFullRateCodec2
FHAMRFRTH23 fhAMRFullRateThresholds23
FHAMRFRC3 fhAMRFullRateCodec3
FHAMRFRTH34 fhAMRFullRateThresholds34
FHAMRFRC4 fhAMRFullRateCodec4
FHAMRHRC1 fhAMRHalfRateCodec1
FHAMRHRTH12 fhAMRHalfRateThresholds12
FHAMRHRC2 fhAMRHalfRateCodec2
FHAMRHRTH23 fhAMRHalfRateThresholds23
FHAMRHRC3 fhAMRHalfRateCodec3
FHAMRHRTH34 fhAMRHalfRateThresholds34
FHAMRHRC4 fhAMRHalfRateCodec4
FHAMRFRIC fhAMRFullRateInitialCodec
FHAMRHRIC fhAMRHRInitialCodec
QSRHI qSearchI
FDDQMI fddQMin
FDDQO fddQOffset
QSRHCINI qSearchCinitial
FDDREPQTY fddReportingQuantity
FDDMURREP fddMultiratReporting
UMTSSRHPRI umtsSearchPriority
EANTHOP enableAntennaHopping
ANTHOPMOD antennaHoppingMode
ANTHOPP antennaHoppingPeriod
GUARMABIS guaranteedMinimumAbis
QSRHC qSearchC
TDDQO tddQOffset
TDDMURREP tddMultiratReporting
REPTYP reportType
ETXDIVTS enableTxDivTimeShift
TXDIVTSEXCPT txDivTimeShiftExcept
TXDIVTSPAR txDivTimeShiftParam
TAADJ taAdjust
LCBM<n> localCellBroadcastMessage<n>
EHRACTAMR enableHRActivationAmr
HRACTAMRT1 hRActivationAmrThreshold1
HRACTAMRT2 hRActivationAmrThreshold2
FRACTTH1 fullRateActivationThreshold1
FRACTTH2 fullRateActivationThreshold2


A30808-X3247-M230-6-7619

249
CML:BSC BTS
Id:0900d805800d4446
FRACTAMRTH1 fullRateActivationAMRThreshold1
FRACTAMRTH2 fullRateActivationAMRThreshold2
EPAT1 enhancedPairingThreshold1
EPAT2 enhancedPairingThreshold2
ENDMA enableDMA
EAC enableAc
ACFERMAX acFERMax
ACBQPMAX acBQPMax
ACPER acPeriod
ACLNKTYP acLinkType
ACBQPFF acBQPFgtFac
ACEFLFF acEFLFgtFac
ACMINEFLDMA acMinEFLDMA
ACMAXEFLDMA acMaxEFLDMA
FRANOFFS frameNumberOffset
BURNOFFS burstNumberOffset
ENPERNOTDE enablePeriodicalNotifDedicatedChan
PNOFACCH periodNotificationFACCH
EHDCTR enableHistoryOnDroppedCallTrace
MEAEXTBCCH measureExtraBCCH
SLLPRM signallingLayerListPrimary
CRTSWSPELLPRM circuitSwitchedSpeechLayerListPrimary
AMRFRLLPRM aMRFullRateLayerListPrimary
AMRHRLLPRM aMRHalfRateLayerListPrimary
CRTSWDLLPRM circuitSwitchedDataLayerListPrimary
HSCSDLLPRM hscsdLayerListPrimary
GLLPRM gprsLayerListPrimary
ELLPRM edgeLayerListPrimary
ASCILLPRM asciLayerListPrimary
CRTSWSPELLCOM circuitSwitchedSpeechLLComp
AMRFRLLCOM aMRFullRateLayerListComplementary
AMRHRLLCOM aMRHalfRateLayerListComplementary
CRTSWDLLCOM circuitSwitchedDataLayerListComp
HSCSDLLCOM hscsLayerListComplementary
GLLCOM gprsLayerListComplementary
ELLCOM edgeLayerListComplementary
DGRSTRGY downgradeStrategy
LWWPSPRI lowestWPSPriority
WPSPREF wPSPreference


250 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
QLWPS queuingLengthWPS
GEXTS gprsExtension
CSCE cellScenario
CUCONF carrierUnitConfiguration
EFCRESEL enableFastCellReselection
FDDRSCPMI fddRscpMin
FDDQMIO fddQMinOffset
FDDREPTH fddReportThreshold
FDDREPO fddReportOffset
TDDREPTH tddReportThreshold
TDDREPO tddReportOffset
FDDREPTH2 fddReportThreshold2
System Responses:
- Operation Completed
NAME:name
CELLGLID:
MCC: mcc
MNC: mnc
LAC: lac
CI: ci
BSIC: bsIdentityCode
NCC: Network Colour Code
BCC: Bs Colour Code
PLMNP: plmnPermitted
CELLRESH: cellReselectHysteresis
MSTXPMAXGSM: msTxPwrMaxGsm
MSTXPMAXDCS: msTxPwrMaxDcs
MSTXPMAXPCS: msTxPwrMaxPcs
RXLEVAMI: rxLevAccessMin
RDLNKTO: radioLinkTimeout
RACHBT: rachBusyThreshold
RACHLAS: rachLoadAveragingSlots
TCCCHLDI: thresholdCcchLoadIndication
PCCCHLDI: periodCcchLoadIndication
FACCHQ: facchQual
CELLTYP: cellType
SYSID:systemIndicator


A30808-X3247-M230-6-7619

251
CML:BSC BTS
Id:0900d805800d4446
BCCHFREQ:bcchFrequency
CALLF01:cellAllocationF01
CALLF02:cellAllocationF02
CALLF03:cellAllocationF03
CALLF04:cellAllocationF04
CALLF05:cellAllocationF05
CALLF06:cellAllocationF06
CALLF07:cellAllocationF07
CALLF08:cellAllocationF08
CALLF09:cellAllocationF09
CALLF10:cellAllocationF10
CALLF11:cellAllocationF11
CALLF12:cellAllocationF12
CALLF13:cellAllocationF13
CALLF14:cellAllocationF14
CALLF15:cellAllocationF15
CALLF16:cellAllocationF16
CALLF17:cellAllocationF17
CALLF18:cellAllocationF18
CALLF19:cellAllocationF19
CALLF20:cellAllocationF20
CALLF21:cellAllocationF21
CALLF22:cellAllocationF22
CALLF23:cellAllocationF23
CALLF24:cellAllocationF24
CALLF25:cellAllocationF25
CALLF26:cellAllocationF26
CALLF27:cellAllocationF27
CALLF28:cellAllocationF28
CALLF29:cellAllocationF29
CALLF30:cellAllocationF30
CALLF31:cellAllocationF31
CALLF32:cellAllocationF32
CALLF33:cellAllocationF33
CALLF34:cellAllocationF34
CALLF35:cellAllocationF35


252 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
CALLF36:cellAllocationF36
CALLF37:cellAllocationF37
CALLF38:cellAllocationF38
CALLF39:cellAllocationF39
CALLF40:cellAllocationF40
CALLF41:cellAllocationF41
CALLF42:cellAllocationF42
CALLF43:cellAllocationF43
CALLF44:cellAllocationF44
CALLF45:cellAllocationF45
CALLF46:cellAllocationF46
CALLF47:cellAllocationF47
CALLF48:cellAllocationF48
CALLF49:cellAllocationF49
CALLF50:cellAllocationF40
CALLF51:cellAllocationF51
CALLF52:cellAllocationF52
CALLF53:cellAllocationF53
CALLF54:cellAllocationF54
CALLF55:cellAllocationF55
CALLF56:cellAllocationF56
CALLF57:cellAllocationF57
CALLF58:cellAllocationF58
CALLF59:cellAllocationF59
CALLF60:cellAllocationF60
CALLF61:cellAllocationF61
CALLF62:cellAllocationF62
CALLF63:cellAllocationF63
CRESPARI:cellReselectionParamInd
CRESOFF:cellReselectOffset
TEMPOFF:temporaryOffset
PENTIME:penaltyTime
CBQ:CellBarQualify
NMULBAC:nMultibandcell
CONCELL:concentricCell
BTSHSCSD:btsHSCSD


A30808-X3247-M230-6-7619

253
CML:BSC BTS
Id:0900d805800d4446
MAXRETR:maxNumberRetrasmission
NSLOTST:numberOfSlotSpreadTrans
NY1:ny1
NBLKACGR:noOfBlocksForAccessGrant
NFRAMEPG:noOfMultiFramesBetweenPaging
MSTXPMAXCH:msTxPwrMaxCcch
PWROFS:powerOffset
ASCISER:advancedSpeechCallItemsService
NOCHFBLK:notificationChannelFirstBlock
NOCHBLKN:notificationChannelBlockNumber
INTCLASS:enableInterferenceClass
INTAVEPR:interferenceAveragingProcess
averPeriod: averPeriod
intThrBou1: intThrBou1
intThsBou2: intThsBou2
intThsBou3: intThsBou3
intThsBou4: intThsBou4
RFRSINDP:rfResourceIndicationPeriod
CELLBARR:cellBarred
CREALL:callReestablishmentAllowed
NALLWACC:
Not Allowed Access Class : notAllowedAccessClasses 0
Not Allowed Access Class : notAllowedAccessClasses 1
Not Allowed Access Class : notAllowedAccessClasses 2
Not Allowed Access Class : notAllowedAccessClasses 3
Not Allowed Access Class : notAllowedAccessClasses 4
Not Allowed Access Class : notAllowedAccessClasses 5
Not Allowed Access Class : notAllowedAccessClasses 6
Not Allowed Access Class : notAllowedAccessClasses 7
Not Allowed Access Class : notAllowedAccessClasses 8
Not Allowed Access Class : notAllowedAccessClasses 9
Not Allowed Access Class : notAllowedAccessClasses 10
Not Allowed Access Class : notAllowedAccessClasses 11
Not Allowed Access Class : notAllowedAccessClasses 12
Not Allowed Access Class : notAllowedAccessClasses 13
Not Allowed Access Class : notAllowedAccessClasses 14


254 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Not Allowed Access Class : notAllowedAccessClasses 15
EC:emergencyCallRestricted
SMSCBUSE:smsCBUsed
DTXDLFR:dTxDownLinkFullRate
DTXDLHR:dTxDownLinkHalfRate
DTXUL:dTxUpLink
IMSIATDT:allowImsiAttachDetach
HOPP:enableHopping
T3212:timerPeriodicUpdateMS
PWROUT:
Output Power Fault Threshold: oPwrFaultThreshold
Reduced Output Power Threshold: redOutPwrThreshold
Excessive Output Power Threshold: excesOutPwrThresh
DIRTCHASS:directTCHAssign
BMONTH:bintChanMonitorThresholds
BSMONTH:bintSignChanMonitorThresholds
EARCLMenableEarlyClassmark
HOPMODE:hoppingMode
EXCDIST:excessiveDistance
EEXCDIST:enableExcessiveDistance
EQ:enableQueuing
EPRE:enablePreemption
T200:
sdcchSAPIO:sdcchSAPIO
facchTCHF: facchTCHF
fac-
chTCHH:
facchTCHH
sacchTCHSAPIO:sacchTCHSAPIO
sacchSDCCH:sacchSDCCH
sdcchSAPI
3:
sdcchSAPI3
sacchTCHSAPI3:sacchTCHSAPI3
T3101:
Tunit:tunit
Tvalue:tvalue
T3105:
Tunit:tunit


A30808-X3247-M230-6-7619

255
CML:BSC BTS
Id:0900d805800d4446
Tvalue:tvalue
T3107:
Tunit: tunit
Tvalue:tvalue
T3109:
Tunit:tunit
Tvalue:tvalue
T3111:
Tunit:tunit
Tvalue:tvalue
TSYNC:tSync
TTRAU:tTrau
TSYNCUL:tSynchronizationUplink
TSYNCDL:tSynchronizationDownlink
TSYNCR:tSynchronizationR
ENANCD:enableNoCallDetection
NCDP1:
StartTime1:StartTime1
TimerNoCall1:TimerNoCall1
NCDP2:
StartTime2:StartTime2
TimerNoCall2:TimerNoCall2
TGRANT:timerGrant
NRPGRANT:numberRepetitionGrant
VGRULF:voiceGroupUplinkFree
TNOCH:timerNotificationChannel
EHRACT:enableHrActivation
HRACTT1:hRActivation Threshold1
HRACTT2:hRActivation Threshold2
SDCCHCONGTH:sdcchCongestionThreshold
ASCIULR:asciUplinkReply
TUPLREP:timerUplinkReply
EEOTD:enableEOTD
AMRFRC1:aMRFullRateCodec1
AMRFRTH12:aMRFullRateThresholds12
AMRFRC2:aMRFullRateCodec2


256 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
AMRFRTH23:aMRFullRateThresholds23
AMRFRC3:aMRFullRateCodec3
AMRFRTH34:aMRFullRateThresholds34
AMRFRC4:aMRFullRateCodec4
AMRHRC1:aMRHalfRateCodec1
AMRHRTH12:aMRHalfRateThresholds12
AMRHRC2:aMRHalfRateCodec2
AMRHRTH23:aMRHalfRateThresholds23
AMRHRC3:aMRHalfRateCodec3
AMRHRTH34:aMRHalfRateThresholds34
AMRHRC4:aMRHalfRateCodec4
AMRFRIC:aMRFullRateInitialCodec
AMRHRIC:aMRHRInitialCodec
AMRLKAT:aMRLinkAdapTuning
QSRHI:qSearchI
FDDQMI:fddQMin
FDDQO:fddQOffset
QSRHCINI:qSearchCinitial
FDDREPQTY:fddReportingQuantity
FDDMURREP:fddMultiratReporting
UMTSSRHPRI:umtsSearchPriority
EANTHOP:enableAntennaHopping
ANTHOPMOD:antennaHoppingMode
ANTHOPP:antennaHoppingPeriod
GUARMABIS:guaranteedMinimumAbis
QSRHC:qSearchC
TDDQO:tddQOffset
TDDMURREP: tddMultiratReporting
REPTYP:reportType
ETXDIVTS:enableTxDivTimeShift
TXDIVTSEXCPT:txDivTimeShiftExcept
TXDIVTSPAR:txDivTimeShiftParam
TAADJ:taAdjust
LCBM0:localCellBroadcastMessage0
MSGID:MSGID
PAGE:PAGE


A30808-X3247-M230-6-7619

257
CML:BSC BTS
Id:0900d805800d4446
REPRATE:REPRATE
SCHEME:SCHEME
LCBM1:localCellBroadcastMessage1
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
LCBM2:localCellBroadcastMessage2
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
LCBM3:localCellBroadcastMessage3
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
HRACTAMRT1: hRActivationAmrThreshold1
HRACTAMRT2: hRActivationAmrThreshold2
EPAT1: enhancedPairingThreshold1
EPAT2: enhancedPairingThreshold2
EHDCTR: enableHDCTR
PNOFACCH: periodNotificationFACHH
ENPERNOTDE: enablePeriodicalNotifDedicatedChan
FHAMRFRC1:fhAMRFullRateCodec1
FHAMRFRTH12:fhAMRFullRateThresholds12
FHAMRFRC2:fhAMRFullRateCodec2
FHAMRFRTH23:fhAMRFullRateThresholds23
FHAMRFRC3:fhAMRFullRateCodec3
FHAMRFRTH34:fhAMRFullRateThresholds34
FHAMRFRC4:fhAMRFullRateCodec4
FHAMRHRC1:fhAMRHalfRateCodec1
FHAMRHRTH12:fhAMRHalfRateThresholds12
FHAMRHRC2:fhAMRHalfRateCodec2
FHAMRHRTH23:fhAMRHalfRateThresholds23
FHAMRHRC3:fhAMRHalfRateCodec3


258 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
FHAMRHRTH34:fhAMRHalfRateThresholds34
FHAMRHRC4:fhAMRHalfRateCodec4
FHAMRFRIC:fhAMRFullRateInitialCodec
FHAMRHRIC:fhAMRHRInitialCodec
CCALL:commonCellAllocation
ENDMA:enableDMA
EAC:enableAc
ACFERMAX:acFERMax
ACBQPMAX:acBQPMax
ACPER:acPeriod
ACLNKTYP:acLinkType
ACBQPFF:acBQPFgtFac
ACEFLFF:acEFLFgtFac
ACMINEFLDMA:acMinEFLDMA
ACMAXEFLDMA:acMaxEFLDMA
MEAEXTBCCH: measureExtraBCCH
SLLPRM:signallingLayerListPrimary
CRTSWSPELLPRM:circuitSwitchedSpeechLayerListPrimarySER-
VICE
AMRFRLLPRM:aMRFullRateLayerListPrimary
AMRHRLLPRM:aMRHalfRateLayerListPrimary
CRTSWDLLPRM:circuitSwitchedDataLayerListPrimarySERVICE
HSCSDLLPRM:hscsdLayerListPrimary
GLLPRM:gprsLayerListPrimary
ELLPRM:edgeLayerListPrimary
ASCILLPRM:asciLayerListPrimary
CRTSWSPELLCOM:circuitSwitchedSpeechLLComp
AMRFRLLCOM:aMRFullRateLayerListComplementarySERVICE
AMRHRLLCOM:aMRHalfRateLayerListComplementarySERVICE
CRTSWDLLCOM:circuitSwitchedDataLayerListCompSERVICE
HSCSDLLCOM:hscsLayerListComplementary
GLLCOM:gprsLayerListComplementary
ELLCOM:edgeLayerListComplementary
DGRSTRGY:downgradesStrategy
FRACTTH1:fRActivationThreshold1
FRACTTH2:fRActivationThreshold2
FRACTAMRTH1:fRActivationAMRThreshold1


A30808-X3247-M230-6-7619

259
CML:BSC BTS
Id:0900d805800d4446
GET BTS BASICS
FRACTAMRTH2:fRActivationAMRThreshold2
EHRACTAMR:enableHrActivationAmr
FRANOFFS: frameNumberOffset
BURNOFFS: burstNumberOffset
QLWPS:queuingLengthWPS
QLPUB:queuingLengthPublic
LWWPSPRI:lowestWPSPriority
WPSPREF:wPSPreference
GEXTS:gPRSExtension
CSCE:cellScenario
FDDREPTH: fddReportThreshold
FDDREPO: fddReportOffset
TDDREPTH: tddReportThreshold
TDDREPO: tddReportOffset
FDDREPTH2: fddReportThreshold2
FDDRSCPMI: fddRscpMin
CUCONF: carrierUnitConfiguration
EFCRESEL: enableFastCellReselection
FDDQMIO: fddQminOffset
NAME:name
CELLGLID:
MCC: mcc
MNC: mnc
LAC: lac
CI: ci
BSIC: bsIdentityCode
NCC: Network Colour Code
BCC: Bs Colour Code
PLMNP: plmnPermitted
CELLRESH: cellReselectHysteresis
MSTXPMAXGSM: msTxPwrMaxGsm
MSTXPMAXDCS: msTxPwrMaxDcs
MSTXPMAXPCS: msTxPwrMaxPcs
RXLEVAMI: rxLevAccessMin


260 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
RDLNKTO: radioLinkTimeout
RACHBT: rachBusyThreshold
RACHLAS: rachLoadAveragingSlots
TCCCHLDI: thresholdCcchLoadIndication
PCCCHLDI: periodCcchLoadIndication
FACCHQ: facchQual
CELLTYP: cellType
CRESPARI:cellReselectionParamInd
CRESOFF:cellReselectOffset
TEMPOFF:temporaryOffset
PENTIME:penaltyTime
CBQ:CellBarQualify
NMULBAC:nMultibandcell
CONCELL:concentricCell
BTSHSCSD:btsHSCSD
HRACTT1:hRActivation Threshold1
HRACTT2:hRActivation Threshold2
SDCCHCONGTH:sdcchCongestionThreshold
EEOTD:enableEOTD
QSRHI:qSearchI
FDDQMI:fddQMin
FDDQO:fddQOffset
QSRHCINI:qSearchCinitial
FDDREPQTY:fddReportingQuantity
FDDMURREP:fddMultiratReporting
UMTSSRHPRI:umtsSearchPriority
EANTHOP:enableAntennaHopping
ANTHOPMOD:antennaHoppingMode
ANTHOPP:antennaHoppingPeriod
QSRHC:qSearchC
TDDQO:tddQOffset
TDDMURREP: tddMultiratReporting
GUARMABIS:guaranteedMinimumAbis
REPTYP:reportType
ETXDIVTS:enableTxDivTimeShift
TXDIVTSEXCPT:txDivTimeShiftExcept


A30808-X3247-M230-6-7619

261
CML:BSC BTS
Id:0900d805800d4446
TXDIVTSPAR:txDivTimeShiftParam
TAADJ:taAdjust
LCBM0:localCellBroadcastMessage0
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
LCBM1:localCellBroadcastMessage1
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
LCBM2:localCellBroadcastMessage2
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
LCBM3:localCellBroadcastMessage3
MSGID:MSGID
PAGE:PAGE
REPRATE:REPRATE
SCHEME:SCHEME
EHRACT: enableHrActivation
EPAT1: enhancedPairingThreshold1
EPAT2: enhancedPairingThreshold2
EHDCTR: enableHDCTR
PNOFACCH: periodNotificationFACCH
ENPERNOTDE: enablePeriodicalNotifDedicatedChan
ENDMA:enableDMA
EAC:enableAc
MEAEXTBCCH:measureExtraBCCH
DGRSTRGY:downgradesStrategy
FRACTTH1:fRActivationThreshold1
FRACTTH2:fRActivationThreshold2
FRANOFFS: frameNumberOffset
BURNOFFS: burstNumberOffset


262 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
GET BTS CCCH
GET BTS INTERF
CSCE: cellScenario
FDDREPTH: fddReportThreshold
FDDREPO: fddReportOffset
TDDREPTH: tddReportThreshold
TDDREPO: tddReportOffset
FDDREPTH2: fddReportThreshold2
FDDRSCPMI: fddRscpMin
CUCONF: carrierUnitConfiguration
FDDQMIO: fddQminOffset
NAME:name
MAXRETR:maxNumberRetrasmission
NSLOTST:numberOfSlotSpreadTrans
NY1:ny1
NBLKACGR:noOfBlocksForAccessGrant
NFRAMEPG:noOfMultiFramesBetweenPaging
MSTXPMAXCH:msTxPwrMaxCcch
PWROFS:powerOffset
ASCISER:advancedSpeechCallItemsService
NOCHFBLK:notificationChannelFirstBlock
NOCHBLKN:notificationChannelBlockNumber
ASCIULR:asciUplinkReply
NAME:name
INTCLASS:enableInterferenceClass
INTAVEPR:interferenceAveragingProcess
averPeriod: averPeriod
intThrBou1: intThrBou1
intThsBou2: intThsBou2
intThsBou3: intThsBou3
intThsBou4: intThsBou4
RFRSINDP:rfResourceIndicationPeriod


A30808-X3247-M230-6-7619

263
CML:BSC BTS
Id:0900d805800d4446
GET BTS OPTIONS
NAME:name
CELLBARR:cellBarred
CREALL:callReestablishmentAllowed
NALLWACC:
Not Allowed Access Class : notAllowedAccessClasses 0
Not Allowed Access Class : notAllowedAccessClasses 1
Not Allowed Access Class : notAllowedAccessClasses 2
Not Allowed Access Class : notAllowedAccessClasses 3
Not Allowed Access Class : notAllowedAccessClasses 4
Not Allowed Access Class : notAllowedAccessClasses 5
Not Allowed Access Class : notAllowedAccessClasses 6
Not Allowed Access Class : notAllowedAccessClasses 7
Not Allowed Access Class : notAllowedAccessClasses 8
Not Allowed Access Class : notAllowedAccessClasses 9
Not Allowed Access Class : notAllowedAccessClasses 10
Not Allowed Access Class : notAllowedAccessClasses 11
Not Allowed Access Class : notAllowedAccessClasses 12
Not Allowed Access Class : notAllowedAccessClasses 13
Not Allowed Access Class : notAllowedAccessClasses 14
Not Allowed Access Class : notAllowedAccessClasses 15
EC:emergencyCallRestricted
SMSCBUSE:smsCBUsed
DTXDLFR:dTxDownLinkFullRate
DTXDLHR:dTxDownLinkHalfRate
DTXUL:dTxUpLink
IMSIATDT:allowImsiAttachDetach
HOPP:enableHopping
T3212:timerPeriodicUpdateMS
PWROUT:
Output Power Fault Threshold: oPwrFaultThreshold
Reduced Output Power Threshold: redOutPwrThreshold
Excessive Output Power Threshold: excesOutPwrThresh
DIRTCHASS:directTCHAssign
BMONTH:bintChanMonitorThresholds


264 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
GET BTS TIMER
BSMONTH:bintSignChanMonitorThresholds
EARCLMenableEarlyClassmark
HOPMODE:hoppingMode
EXCDIST:excessiveDistance
EEXCDIST:enableExcessiveDistance
EQ:enableQueuing
QLPUB:queuingLenghtPublic
EPRE:enablePreemption
EFCRESEL: enableFastCellReselection
QLWPS:queuingLenghtWPS
LWWPSPRI:lowestWSPriority
WPSPREF:wPSPreference
GEXTS:gprsExtension
NAME:name
T200:
sdcchSAPIO:sdcchSAPIO
facchTCHF: facchTCHF
fac-
chTCHH:
facchTCHH
sacchTCHSAPIO:sacchTCHSAPIO
sacchSDCCH:sacchSDCCH
sdcchSAPI
3:
sdcchSAPI3
sacchTCHSAPI3:sacchTCHSAPI3
T3101:
Tunit:tunit
Tvalue:tvalue
T3105:
Tunit:tunit
Tvalue:tvalue
T3107:
Tunit: tunit
Tvalue:tvalue
T3109:


A30808-X3247-M230-6-7619

265
CML:BSC BTS
Id:0900d805800d4446
GET BTS AMRPARAMETERS
Tunit:tunit
Tvalue:tvalue
T3111:
Tunit:tunit
Tvalue:tvalue
TSYNC:tSync
TTRAU:tTrau
TSYNCUL:tSynchronizationUplink
TSYNCDL:tSynchronizationDownlink
TSYNCR:tSynchronizationR
ENANCD:enableNoCallDetection
NCDP1:
StartTime1:StartTime1
TimerNoCall1:TimerNoCall1
NCDP2:
StartTime2:StartTime2
TimerNoCall2:TimerNoCall2
TGRANT:timerGrant
NRPGRANT:numberRepetitionGrant
VGRULF:voiceGroupUplinkFree
TNOCH:timerNotificationChannel
TUPLREP:timerUplinkReply
NAME:name
AMRFRC1:aMRFullRateCodec1
AMRFRTH12:aMRFullRateThresholds12
AMRFRC2:aMRFullRateCodec2
AMRFRTH23:aMRFullRateThresholds23
AMRFRC3:aMRFullRateCodec3
AMRFRTH34:aMRFullRateThresholds34
AMRFRC4:aMRFullRateCodec4
AMRHRC1:aMRHalfRateCodec1
AMRHRTH12:aMRHalfRateThresholds12
AMRHRC2:aMRHalfRateCodec2
AMRHRTH23:aMRHalfRateThresholds23


266 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
GET BTS ADM
AMRHRC3:aMRHalfRateCodec3
AMRHRTH34:aMRHalfRateThresholds34
AMRHRC4:aMRHalfRateCodec4
AMRFRIC:aMRFullRateInitialCodec
AMRHRIC:aMRHRInitialCodec
AMRLKAT:aMRLinkAdapTuning
HRACTAMRT1: hRActivationAmrThreshold1
HRACTAMRT2: hRActivationAmrThreshold2
FHAMRFRC1:fhAMRFullRateCodec1
FHAMRFRTH12:fhAMRFullRateThresholds12
FHAMRFRC2:fhAMRFullRateCodec2
FHAMRFRTH23:fhAMRFullRateThresholds23
FHAMRFRC3:fhAMRFullRateCodec3
FHAMRFRTH34:fhAMRFullRateThresholds34
FHAMRFRC4:fhAMRFullRateCodec4
FHAMRHRC1:fhAMRHalfRateCodec1
FHAMRHRTH12:fhAMRHalfRateThresholds12
FHAMRHRC2:fhAMRHalfRateCodec2
FHAMRHRTH23:fhAMRHalfRateThresholds23
FHAMRHRC3:fhAMRHalfRateCodec3
FHAMRHRTH34:fhAMRHalfRateThresholds34
FHAMRHRC4:fhAMRHalfRateCodec4
FHAMRFRIC:fhAMRFullRateInitialCodec
FHAMRHRIC:fhAMRHRInitialCodec
FRACTAMRTH1:fRActivationAMRThreshold1
FRACTAMRTH2:fRActivationAMRThreshold2
EHRACTAMR:enableHrActivationAmr
NAME:name
ACFERMAX:acFERMax
ACBQPMAX:acBQPMax
ACPER:acPeriod
ACLNKTYP:acLinktype
ACBQPFF:acBQPFgFac
ACEFLFF:acEFLFgtFac


A30808-X3247-M230-6-7619

267
CML:BSC BTS
Id:0900d805800d4446
GET BTS CELLFREQDEFINITION
ACMINEFLDMA:acMinEFLDMA
ACMAXEFLDMA:acMaxEFDLMA
NAME:name
SYSID:systemIndicator
BCCHFREQ:bcchFrequency
CCALL:commonCellAllocation
CALLF01:cellAllocationF01
CALLF02:cellAllocationF02
CALLF03: cellAllocationF03
CALLF04: cellAllocationF04
CALLF05: cellAllocationF05
CALLF06: cellAllocationF06
CALLF07: cellAllocationF07
CALLF08: cellAllocationF08
CALLF09: cellAllocationF09
CALLF10: cellAllocationF10
CALLF11: cellAllocationF11
CALLF12: cellAllocationF12
CALLF13: cellAllocationF13
CALLF14: cellAllocationF14
CALLF15: cellAllocationF15
CALLF16: cellAllocationF16
CALLF17: cellAllocationF17
CALLF18: cellAllocationF18
CALLF19: cellAllocationF19
CALLF20: cellAllocationF20
CALLF21: cellAllocationF21
CALLF22: cellAllocationF22
CALLF23: cellAllocationF23
CALLF24: cellAllocationF24
CALLF25: cellAllocationF25
CALLF26: cellAllocationF26
CALLF27: cellAllocationF27
CALLF28: cellAllocationF28


268 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
CALLF29: cellAllocationF29
CALLF30: cellAllocationF30
CALLF31: cellAllocationF31
CALLF32: cellAllocationF32
CALLF33: cellAllocationF33
CALLF34: cellAllocationF34
CALLF35: cellAllocationF35
CALLF36: cellAllocationF36
CALLF37: cellAllocationF37
CALLF38: cellAllocationF38
CALLF39: cellAllocationF39
CALLF40: cellAllocationF40
CALLF41: cellAllocationF41
CALLF42: cellAllocationF42
CALLF43: cellAllocationF43
CALLF44: cellAllocationF44
CALLF45: cellAllocationF45
CALLF46: cellAllocationF46
CALLF47: cellAllocationF47
CALLF48: cellAllocationF48
CALLF49: cellAllocationF49
CALLF50: cellAllocationF50
CALLF51: cellAllocationF51
CALLF52: cellAllocationF52
CALLF53: cellAllocationF53
CALLF54: cellAllocationF54
CALLF55: cellAllocationF55
CALLF56: cellAllocationF56
CALLF57: cellAllocationF57
CALLF58: cellAllocationF58
CALLF59: cellAllocationF59
CALLF60: cellAllocationF60
CALLF61: cellAllocationF61
CALLF62: cellAllocationF62
CALLF63: cellAllocationF63


A30808-X3247-M230-6-7619

269
CML:BSC BTS
Id:0900d805800d4446
GET BTS SERVICE
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET BTS BASICS
None.
GET BTS CCCH
None.
GET BTS INTERF
None.
GET BTS OPTIONS
NAME:name
SLLPRM: signallingLayerListPrimary
CRTSWSPELLPRM: circuitSwitchedSpeechLayerListPrimary
AMRFRLLPRM: aMRFullRateLayerListPrimary
AMRHRLLPRM: aMRHalfRateLayerListPrimary
CRTSWDLLPRM: circuitSwitchedDataLayerListPrimary
HSCSDLLPRM: hscsdLayerListPrimary
GLLPRM: gprsLayerListPrimary
ELLPRM: edgeLayerListPrimary
ASCILLPRM: asciLayerListPrimary
CRTSWSPELLCOM: circuitSwitchedSpeechLLComp
AMRFRLLCOM: aMRFullRateLayerListComplementary
AMRHRLLCOM: aMRFullRateLayerListComplementary
CRTSWDLLCOM: circuitSwitchedDataLayerListComp
HSCSDLLCOM: hscsLayerListComplementary
GLLCOM: gprsLayerListComplementary
ELLCOM: edgeLayerListComplementary
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


270 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
None.
GET BTS TIMER
None.
Example of Command Execution:
Get BTS:NAME=BTSM:0/BTS:0,REQATTL=CELLGLID&BSIC&PLMNP&CELLRESH&
MSTXPMAXGSM&MSTXPMAXDCS&MSTXPMAXPCS&RXLEVAMI&
RDLNKTO&RACHBT&RACHLAS&TCCCHLDI&PCCCHLDI&FACCHQ&CELLTYP&
SYSID&BCCHFREQ&CALLF01&CALLF02&CALLF03&CALLF04&CALLF05&
CALLF06&CALLF07&CALLF08&CALLF09&CALLF10&CALLF11&CALLF12&
CALLF13&CALLF14&CALLF15&CALLF16&CALLF17&CALLF18&CALLF19&
CALLF20&CALLF21&CALLF22&CALLF23&CALLF24&CALLF25&CALLF26&
CALLF27&CALLF28&CALLF29&CALLF30&CALLF31&CALLF32&CALLF33&
CALLF34&CALLF35&CALLF36&CALLF37&CALLF38&CALLF39&CALLF40&
CALLF41&CALLF42&CALLF43&CALLF44&CALLF45&CALLF46&CALLF47&
CALLF48&CALLF49&CALLF50&CALLF51&CALLF52&CALLF53&CALLF54&
CALLF55&CALLF56&CALLF57&CALLF58&CALLF59&CALLF60&CALLF61&
CALLF62&CALLF63&CRESPARI&CRESOFF&TEMPOFF&PENTIME&CBQ&
NMULBAC&CONCELL&BTSHSCSD&MAXRETR&
NSLOTST&NY1&NBLKACGR&NFRAMEPG&MSTXPMAXCH&PWROFS&
ASCISER&NOCHFBLK&NOCHBLKN&INTCLASS&INTAVEPR&RFRSINDP&
CELLBARR&CREALL&NALLWACC&EC&SMSCBUSE&DTXDLFR&
DTXDLHR&DTXUL&IMSIATDT&HOPP&T3212&PWROUT&DIRTCHASS&
BMONTH&BSMONTH&EARCLM&HOPMODE&EXCDIST&EEX-
CDIST&EQ&EPRE&T200&T3101&T3105&T3107&T3109&T3111&TSYNC&TSYN-
CUL&
TSYN-
CDL&TSYNCR&TTRAU&ENANCD&NCDP1&NCDP2&TGRANT&NRPGRANT&VGR
ULF&TNOCH&EHRACT&HRACTT1&HRACTT2&SDCCHCONGTH& ASCI-
ULR&TUPLREP&EEOTD&AMRFRC1&AMRFRTH12&AMRFRC2&
AMRFRTH23&AMRFRC3&AMRFRTH34&AMRFRC4&AMRHRC1&AMRHRTH12&
AMRHRC2&AMRHRTH23&AMRHRC3&AMRHRTH34&AMRHRC4&AMRFRIC&
AMRHRIC&AMRLKAT&QSRHI&FDDQMI&FDDQO&QSRHCINI&FDDREPQTY&
FDDMURREP&UMTSSRHPRI&EANTHOP&ANTHOPMOD&ANTHOPP&
GUARMABIS&QSRHC&TDDQTDDMURREP&REPTYP&ETXDIVTS&TXDIVTSEX-
CPT&TXDIVTSPAR&TAADJ&LCBM0&LCBM1&LCBM2&LCBM3&
HRACTAMRT1&HRACTAMRT2&EPAT1&EPAT2&EHDCTR&PNOFACCH&ENPER-
NOTDE&ENDMA&CCALL&FHAMRFRC1&&FHAMRFRC2&FHAMRFRC3&FHAMRF
RC4&FHAMRFRTH12&FHAMRFRTH23&FHAMRFRTH34&FHAMRHRC1&FHAMRH
RC2&FHAMRHRC3&FHAMRHRC4&FHAMRHRTH12&FHAMRHRTH23&FHAMRHR
TH34&FHAMRFRIC&FHAMRHRIC&EAC&ACFERMAX&ACBQPMAX&ACPER&
ACLNKTP&ACBQPFF&ACEFLFF& ACMINEFLDMA&ACMAXELDMA&MEAEXTB-
CCH&SLLPRM&CRTSWSPELLPRM&AMRFRLLPRM&AMRHRLLPRMRM&


A30808-X3247-M230-6-7619

271
CML:BSC BTS
Id:0900d805800d4446
CRTSWDLLPRM&GLLPRM&ELLPRM&ASCILLPRM&HSCSDLLPRM&
CRTSWSPELLCOM&AMRFRLLCOM&AMRHRLLCOM&CRTSWDLLCOM&
GLLCOM&ELLCOM&HSCSDLLCOM&FRACTTH1&FRACTTH2& FRACTAMRTH1
&FRACTAMRTH2&EHRACTAMR&BURNOFFS &FRANOFFS &WPSPREF&
LWWPSPRI&QLPUB&QLWPS&GEXTS&CSCE&FDDREPO&FDDREPTH&TDDREP
O&TDDREPTH&FDDREPTH2&FDDRSCPMI&CUCONF&EFCRESEL&FDDQMIO;
GET BTS BASICS
Get BTS BASICS:NAME=BTSM:0/BTS:0;
GET BTS CCCH
Get BTS CCCH:NAME=BTSM:0/BTS:0;
GET BTS INTERF
Get BTS INTERF:NAME=BTSM:0/BTS:0;
GET BTS OPTIONS
Get BTS OPTIONS:NAME=BTSM:0/BTS:0;
GET BTS TIMER
Get BTS TIMER:NAME=BTSM:0/BTS:0;
GET BTS AMRPARAMETERS
Get BTS AMRPARAMETERS:NAME=BTSM:0/BTS:0;
Get BTS ADM
Get BTS ADM:NAME=BTSM:0/BTS:0;
Get BTS CELLFREQDEFINITION
Get BTS CELLFREQDEFINITION:NAME=BTSM:0/BTS:0;
Get BTS SERVICE
Get BTS SERVICE:NAME=BTSM:0/BTS:0;
GET BTS ADM
GET BTS ADM NAME=BTSM:0..199/BTS:0..23;


272 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS ADM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
ACFERMAX acFERMax
ACBQPMAX acBQPMax
ACPER acPeriod
ACLNKTYP acLinkType
ACBQPFF acBQPFgtFac
ACEFLFF acEFLFgtFac
ACMINEFLDMA acMinEFLDMA
ACMAXEFLDMA acMaxEFLDMA
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS AMRPARAMETERS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS AMRPA-
RAMETERS
Applicability:
Phase 2.
Visibility level: 0.
GET BTS AMRPARAM-
ETERS
NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

273
CML:BSC BTS
Id:0900d805800d4446
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
AMRFRC1 aMRFullRateCodec1
AMRFRTH12 aMRFullRateThresholds12
AMRFRC2 aMRFullRateCodec2
AMRFRTH23 aMRFullRateThresholds23
AMRFRC3 aMRFullRateCodec3
AMRFRTH34 aMRFullRateThresholds34
AMRFRC4 aMRFullRateCodec4
AMRHRC1 aMRHalfRateCodec1
AMRHRTH12 aMRHalfRateThresholds12
AMRHRC2 aMRHalfRateCodec2
AMRHRTH23 aMRHalfRateThresholds23
AMRHRC3 aMRHalfRateCodec3
AMRHRTH34 aMRHalfRateThresholds34
AMRHRC4 aMRHalfRateCodec4
AMRFRIC aMRFullRateInitialCodec
AMRHRIC aMRHRInitialCodec
AMRLKAT aMRLinkAdapTuning
FHAMRFRC1 fhAMRFullRateCodec1
FHAMRFRTH12 fhAMRFullRateThresholds12
FHAMRFRC2 fhAMRFullRateCodec2
FHAMRFRTH23 fhAMRFullRateThresholds23
FHAMRFRC3 fhAMRFullRateCodec3
FHAMRFRTH34 fhAMRFullRateThresholds34
FHAMRFRC4 fhAMRFullRateCodec4
FHAMRHRC1 fhAMRHalfRateCodec1
FHAMRHRTH12 fhAMRHalfRateThresholds12
FHAMRHRC2 fhAMRHalfRateCodec2
FHAMRHRTH23 fhAMRHalfRateThresholds23
FHAMRHRC3 fhAMRHalfRateCodec3
FHAMRHRTH34 fhAMRHalfRateThresholds34
FHAMRHRC4 fhAMRHalfRateCodec4
FHAMRFRIC fhAMRFullRateInitialCodec
FHAMRHRIC fhAMRHRInitialCodec
EHRACTAMR enableHRActivationAmr


274 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
HRACTAMRT1 hRActivationAmrThreshold1
HRACTAMRT2 hRActivationAmrThreshold2
FRACTAMRTH1 fullRateActivationAMRThreshold1
FRACTAMRTH2 fullRateActivationAMRThreshold2
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
PLMNP plmnPermitted
CELLRESH cellReselectHysteresis
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
RXLEVAMI rxLevAccessMin
RDLNKTO radioLinkTimeout
RACHBT rachBusyThreshold
RACHLAS rachLoadAveragingSlots
TCCCHLDI thresholdCcchLoadIndication
PCCCHLDI periodCcchLoadIndication
GET BTS BASICS NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

275
CML:BSC BTS
Id:0900d805800d4446
FACCHQ facchQual
CELLTYP cellType
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
NMULBAC nMultibandcell
CONCELL concentricCell
BTSHSCSD btsHSCSD
EHRACT enableHrActivation
HRACTT1 hRActivationThreshold1
HRACTT2 hRActivationThreshold2
SDCCHCONGTH sdcchCongestionThreshold
EEOTD enableEOTD
QSRHI qSearchI
FDDQMI fddQMin
FDDQO fddQOffset
QSRHCINI qSearchCinitial
FDDREPQTY fddReportingQuantity
FDDMURREP fddMultiratReporting
UMTSSRHPRI umtsSearchPriority
EANTHOP enableAntennaHopping
ANTHOPMOD antennaHoppingMode
ANTHOPP antennaHoppingPeriod
GUARMABIS guaranteedMinimumAbis
QSRHC qSearchC
TDDQO tddQOffset
TDDMURREP tddMultiratReporting
REPTYP reportType
ETXDIVTS enableTxDivTimeShift
TXDIVTSEXCPT txDivTimeShiftExcept
TXDIVTSPAR txDivTimeShiftParam
TAADJ taAdjust
LCBM<n> localCellBroadcastMessage<n>
FRACTTH1 fullRateActivationThreshold1
FRACTTH2 fullRateActivationThreshold2
EPAT1 enhancedPairingThreshold1
EPAT2 enhancedPairingThreshold2


276 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
ENDMA enableDMA
EAC enableAc
FRANOFFS frameNumberOffset
BURNOFFS burstNumberOffset
ENPERNOTDE enablePeriodicalNotifDedicatedChan
PNOFACCH periodNotificationFACCH
EHDCTR enableHistoryOnDroppedCallTrace
MEAEXTBCCH measureExtraBCCH
DGRSTRGY downgradeStrategy
CSCE cellScenario
CUCONF carrierUnitConfiguration
FDDRSCPMI fddRscpMin
FDDQMIO fddQMinOffset
FDDREPTH fddReportThreshold
FDDREPO fddReportOffset
TDDREPTH tddReportThreshold
TDDREPO tddReportOffset
FDDREPTH2 fddReportThreshold2
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS CCCH
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS CCCH
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
GET BTS CCCH NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

277
CML:BSC BTS
Id:0900d805800d4446
Long Names:
NAME Addres of the managed object
MAXRETR maxNumberRetransmission
NSLOTST numberOfSlotSpreadTrans
NY1 ny1
NBLKACGR noOfBlocksForAccessGrant
NFRAMEPG noOfMultiFramesBetweenPaging
MSTXPMAXCH msTxPwrMaxCcch
PWROFS powerOffset
ASCISER advancedSpeechCallItemsService
NOCHFBLK notificationChannelFirstBlock
NOCHBLKN notificationChannelBlockNumber
ASCIULR asciUplinkReply
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS CELLFREQDEFINITION
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS CELLFREQ-
DEFINITION
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
SYSID systemIndicator
BCCHFREQ bcchFrequency
GET BTS CELLFREQ-
DEFINITION
NAME=BTSM:0..199/BTS:0..23;


278 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
CALLF<nn> cellAllocationF<nn>
CCALL commonCellAllocation
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS INTERF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS INTERF
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
INTCLASS enableInterferenceClass
INTAVEPR interferenceAveragingProcess
RFRSINDP rfResourceIndicationPeriod
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS OPTIONS
GET BTS INTERF NAME=BTSM:0..199/BTS:0..23;
GET BTS OPTIONS NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

279
CML:BSC BTS
Id:0900d805800d4446
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS OPTIONS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
CELLBARR cellBarred
CREALL callReestablishmentAllowed
NALLWACC notAllowedAccessClasses
EC emergencyCall
SMSCBUSE smsCBUsed
DTXDLFR dTxDownLinkFullRate
DTXDLHR dTxDownLinkHalfRate
DTXUL dTxUplink
IMSIATDT allowImsiAttachDetach
HOPP enableHopping
T3212 btsTimer3212
PWROUT powerOutputThresholds
DIRTCHASS directTchAssignment
BMONTH bintChanMonitorThresholds
BSMONTH bintSignChanMonitorThresholds
EARCLM enableEarlyClassmark
HOPMODE hoppingMode
EXCDIST excessiveDistance
EEXCDIST enableExcessiveDistance
EQ enableQueuing
QLPUB queuingLengthPublic
EPRE enablePreemption
LWWPSPRI lowestWPSPriority
WPSPREF wPSPreference
QLWPS queuingLengthWPS
GEXTS gprsExtension
EFCRESEL enableFastCellReselection


280 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS SERVICE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS SERVICE
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
SLLPRM signallingLayerListPrimary
CRTSWSPELLPRM circuitSwitchedSpeechLayerListPrimary
AMRFRLLPRM aMRFullRateLayerListPrimary
AMRHRLLPRM aMRHalfRateLayerListPrimary
CRTSWDLLPRM circuitSwitchedDataLayerListPrimary
HSCSDLLPRM hscsdLayerListPrimary
GLLPRM gprsLayerListPrimary
ELLPRM edgeLayerListPrimary
ASCILLPRM asciLayerListPrimary
CRTSWSPELLCOM circuitSwitchedSpeechLLComp
AMRFRLLCOM aMRFullRateLayerListComplementary
AMRHRLLCOM aMRHalfRateLayerListComplementary
CRTSWDLLCOM circuitSwitchedDataLayerListComp
HSCSDLLCOM hscsLayerListComplementary
GLLCOM gprsLayerListComplementary
ELLCOM edgeLayerListComplementary
GET BTS SERVICE NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

281
CML:BSC BTS
Id:0900d805800d4446
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS TIMER
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS TIMER
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the cell global parameters of a previously created
BTSB.
Long Names:
NAME Addres of the managed object
T200 t200
T3101 btsTimer3101
T3105 btsTimer3105
T3107 btsTimer3107
T3109 btsTimer3109
T3111 btsTimer3111
TSYNC tSync
TSYNCUL tSynchronizationUplink
TSYNCDL tSynchronizationDownlink
TSYNCR tSynchronizationR
TTRAU tTrau
ENANCD enableNoCallDetection
NCDP1 noCallDetectionPeriod1
NCDP2 noCallDetectionPeriod2
TGRANT timerGrant
NRPGRANT numberRepetitionGrant
VGRULF voiceGroupUplinkFree
GET BTS TIMER NAME=BTSM:0..199/BTS:0..23;


282 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
TNOCH timerNotificationChannel
TUPLREP timerUplinkReply
System Responses:
See GET BTS
Application Guidelines:
See GET BTS
Example of Command Execution:
See GET BTS
GET BTS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GET BTS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the BTS
object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
GET BTS STAT NAME=BTSM:0..199/BTS:0..23;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

283
CML:BSC BTS
Id:0900d805800d4446
Application Guidelines:
None.
Example of Command Execution:
Get BTS STAT:NAME=BTSM:0/BTS:0;
GETINFO BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GETINFO BTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The report complete indication.
2. The administrative state (AST), the operational state (OST), the usage state (UST),
the availability status (AVS) and the procedural status (PRS) of the BTS.
3. The BTS absolute number.
4. The location of the signalling channels: BCCH, CBCH and SDCCH.
5. The barred cell information (status and reason); please note that the Cell Barred
Status is not meaningful when
cell is barred because there are no SS7Ls available or
the operator directly bars the cell, setting the CBQ and CELLBARR attributes of
the BTS.
6. The "IsHopping" information.
7. Switch beams EnableTxDiversityTimeShift.
8. Switch beams RX switch with current setting (values: PERIODICAL, NORMAL,
DIVERSITY).
9. If the switch beam functionality has been enabled via patch:
Switched beam capability, which can assume the following values: NONE,
4_BEAMS;
Switched beam service state, which can assume the following values:
OUT_OF_SERVICE, IN_SERVICE, DEGRADED_SERVICE,
DISABLED_SERVICE.
10. The "AntennaHoppingStatus" information.
11. The Cell Global Identifier information.
The object instance must be already equipped.
GETINFO BTS NAME=BTSM:0..199/BTS:0..23;


284 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
12. The Routing Area (RA) code.
13. The prefBandDbMs attribute.
14. The GPRS available information.
15. The BVCI.
16. Enable GPRS (TRUE/FALSE).
17. Enable EDGE (TRUE/FALSE).
18. The BTS capability (UNKNOWN, GSM, EDGE, NOT_APPLICABLE).
19. The BTS configuration (GSM, EDGE, NOT_APPLICABLE).
20. The BTS packet service availability (NONE, GPRS, EGPRS).
21. The BCCH TRX.
22. The location of the GPRS signalling channels: PBCCH and PCCCH.
23. The GPRS Maximum number of reserved PDCHs.
24. The EDGE Maximum number of reserved PDCHs.
25. Full rate speech: number of CHANs used for full rate speech.
26. Full rate data: number of CHANs used for full rate data.
27. Half rate speech: number of subCHANs used for half rate speech calls (number of
calls).
28. Packet: number of CHANs used for packet service.
29. The primary service list containing, for each service, the list of the layers.
30. The complementary service list containing, for each service, the list of the layers.
31. The primary packet area service availability information.
32. The complementary packet area service availability information.
33. For each TRX of the BTS:
the state and statuses: AST, OST, UST, AVS, PRS;
the TRX absolute number;
the TRX capability (UNKNOWN, GSM, EDGE);
the TRX mode (UNKNOWN, GSM, EDGE);
the GPRS support (TRUE/FALSE). (*)
34. For each CHAN of the TRX: the type, the pool type, the usage mode, the
administrative, operational, usage states, the availability status and the service
modality. Service can assume the following values: CS_EFR, CS_AMR_FR,
CS_AMR_HR, CS_DATA, HSCSD, ASCI, SIGNALLING, PACKED,
GPRS_DEDICATED, NO_DEDICATED, CS_FR, CS_HR, CS_2HR,
CS_AMR_2HR, AMR_HR_CS_HR.
(*) Note that up to now, the GSUP information considers only if the layer to which the
TRX belongs, is associated or not to a packet service (GPRS or EDGE). This informa-
tion has been extended to the following parameters and conditions:
1. TRX area: packet service is not allowed in INNER area;
2. gprsExtension (GEXTS): packet service on non-bcch bands is allowed only if this
parameter allows it.
3. CHANNELS: a CHAN can be used for packet service if:


A30808-X3247-M230-6-7619

285
CML:BSC BTS
Id:0900d805800d4446
the extendedMode (EXTMOSE) is set to False
hopping mode is set to BBHOP, the radio timeslot '0' can't be used for packet
service
CHTYPE has value TCHFULL, TCHF_HLF or TCHSD and the channelPool-
Type is equal to TCHPOOL
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO BTS ACK:
BSC_CONTROLLER -> LMT_LOCAL
03:21:35 01/01/1992
*** INFORMATION ***
GET INFO REPORT BTS:
NAME = BTS:112
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
USAGE STATE: IDLE
AVAILABILITY STATUS: NONE
PROCEDURAL STATUS: NONE
BTS ABSOLUTE NR: 3
BCCH CHAN: 3-0-0
CBCH CHAN: 3-0-1
SDCCH CHAN: 3-0-1 3-0-2 3-0-3 3-2-1 3-1-2 3-1-3
3-1-4 3-1-6 ...; ...;
CELL BARRED: TRUE
CELL BARRED REASON FAILED_HOPPING
BTS IS HOPPING: TRUE
ENABLE TX DIVERSITY TIME SHIFT: FALSE
RX SWITCH CURRENT SETTING: PERIODICAL
SWITCHED BEAM CAPABILITY: 4_BEAMS
SWITCHED BEAM SERVICE STATE: DISABLED_SERVICE
ANTENNA HOPPING STATUS: TRUE
CELL GLOBAL ID: 123-32-387-984


286 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
RA CODE: 3
GPRS AVAILABLE: TRUE
BVCI: 3
ENABLE GPRS: TRUE
ENABLE EDGE: FALSE
BTS CAPABILITY: EDGE
BTS CONFIGURATION: EDGE
BTS PACKET SERVICE AVAILABILITY: EGPRS
BCCH TRX: 2
PBCCH MAP: 2
PCCCH MAP: 5 6 7
GPRS MAX. NUMBER PDCH RESERVED PRIMARY: 45
GPRS MAX. NUMBER PDCH RESERVED COMPLEMENTARY: 4
EDGE MAX. NUMBER PDCH RESERVED PRIMARY: 100
EDGE MAX. NUMBER PDCH RESERVED COMPLEMENTARY: 20
FULL SPEECH BUSY CH: 20
FULL DATA BUSY CH: 5
HALF SPEECH BUSY SUBCH: 3
PACKET BUSY CH: 5
PRIMARY SERVICE LIST LAYERS
CS EFR FR HR: 1 2 3
CS AMR FR: 4
CS AMR HR: 1 4
CS DATA: 5 6 10 11
HSCSD: 5 6
GPRS: 7 8
ASCI: 9
SIGNALLING: 0
COMPLEMENTARY SERVICE LIST LAYERS (LY#)
CS EFR FR HR: 0 1 2 3 4 5 6 10 11 7 8 9
PRIMARY AREA PACKET SERVICE AVAILABILITY: GPRS-EGPRS


A30808-X3247-M230-6-7619

287
CML:BSC BTS
Id:0900d805800d4446
COMPLEMENTARY AREA PACKET SERVICE AVAILABILITY: EGPRS
TRX 0:
ADMINISTRATIVE: UNLOCKED
OPERATIONAL: ENABLED
USAGE: IDLE
AVAILABILITY: NONE
PROCEDURAL: NONE
TRX ABSOLUTE NUMBER: 567
TRX CAPABILITY: GSM
TRX MODE: EDGE
GPRS SUPPORTED: TRUE
CHAN NR TYPE POOL TYPE USAGE MODE ADMINISTRATIVE
0 FULL_RATE_ONLY NULL NULL UNLOCKED
1 SDCCH NULL NULL UNLOCKED
2 SDCCH NULL NULL UNLOCKED
3 TCH_SD SDCCH_POOL NULL UNLOCKED
4 TCH_SD TCH_POOL NULL LOCKED
5 TCH_FULL NULL NULL UNLOCKED
6 TCH_FULL NULL NULL UNLOCKED
7 TCH_SD TCH_SD_POOL MODE_TCH UNLOCKED
CHAN NR OPERATIONAL USAGE AVAILABILITY SERVICE
0 ENABLED IDLE NONE NO_DEDICATED
1 ENABLED IDLE NONE NO_DEDICATED
2 ENABLED IDLE NONE NO_DEDICATED
3 ENABLED IDLE NONE NO_DEDICATED
4 ENABLED IDLE NONE NO_DEDICATED
5 ENABLED BUSY NONE CS_EFR
6 ENABLED BUSY NONE PACKET
7 ENABLED BUSY NONE CS_AMR_FR
TRX 1:
ADMINISTRATIVE: UNLOCKED
OPERATIONAL: DISABLED
USAGE: IDLE
AVAILABILITY: REMOTE_DEPENDECY OFF_LINE


288 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
PROCEDURAL: NONE
TRX ABSOLUTE NUMBER: 567
TRX CAPABILITY: GSM
TRX MODE: EDGE
GPRS SUPPORTED: TRUE
CHAN NR TYPE POOL TYPE USAGE MODE ADMINISTRATIVE
0 TCH_FULL NULL NULL UNLOCKED
1 TCH_FULL NULL NULL UNLOCKED
2 TCH_FULL NULL NULL UNLOCKED
3 TCH_SD SDCCH_POOL NULL UNLOCKED
4 TCH_SD TCH_POOL NULL LOCKED
5 TCH_FULL NULL NULL UNLOCKED
6 TCH_FULL NULL NULL UNLOCKED
7 TCH_SD TCH_SD_POOL NULL LOCKED
CHAN NR OPERATIONAL USAGE AVAILABILITY SERVICE
0 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
1 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
2 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
3 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
4 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
5 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
6 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
7 DISABLED NOT_APPLICABLE DEPENDENCY NO_DEDICATED
END OF REPORT
- Operation Failed
GETINFO BTS NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1***
Get Info Report Nack BTS:
name = BTS:112
nackCause = <nack cause>


A30808-X3247-M230-6-7619

289
CML:BSC BTS
Id:0900d805800d4446
NACK CAUSES:
Application Guidelines:
1. CELL BARRED Status attribute is not meaningful when the cell is barred because
there are no SS7Ls available or when the operator directly bars the cell setting the
attributes CBQ and CBA of the BTS.
2. The CELL BARRED REASON information is reserved for the developer.
3. TRXs that are not equipped in the BTS are not shown in the report.
Example of Command Execution:
Getinfo BTS:NAME=BTSM:0/BTS:0;
GETRELATIONSHIP BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GETRELATIONSHIP
BTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the BTS object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW, PPXL and all the BTSE HMOs that implement the TRX
functionality for a certain BTS.
For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR,
GPSU, LI, PA, RXMUCO, RXAMOD and TPU.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the system.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
BTS
NAME=BTSM:0..199/BTS:0..23;


290 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
For BS-4x/240/241/240XL, the BTSE HMOs are: COBA, COSA, CU, DIDCTMA, DILNA,
DUDCTMA, DULNA, DUVSWR, FTNFP, FVSWRP and TMA.
For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship BTS:NAME=BTSM:0/BTS:0;
GETSUBO BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS GETSUBO BTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object does not provide any relationship attribute.
GETSUBO BTS NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

291
CML:BSC BTS
Id:0900d805800d4446
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo BTS:NAME=BTSM:0/BTS:0;
LOCK BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS LOCK BTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK BTS NAME=BTSM:0..199/BTS:0..23;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


292 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock BTS:NAME=BTSM:0/BTS:0;
MONITOR BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS MONITOR BTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command allows to display the alarm state of the interfaces.
One object monitors the A interface, and there is one object to monitor the Abis interface
for each BTS present in the BSC, and another object monitors the O&M interface.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output can be composed by one or more pack with a maximum number of five mne-
monics of objects enqueued in the monitor queue specified; at the end, a message is
displayed notifying the end of the monitor list.
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Monitor BTS:NAME=BTSM:0/BTS:0;
MONITOR BTS NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

293
CML:BSC BTS
Id:0900d805800d4446
SET BTS
SET BTS NAME=BTSM:0..199/BTS:0..23 [,CELLGLID=] [,BSIC=]
[,PLMNP=] [,CELLRESH=] [,MSTXPMAXGSM=] [,MSTXP-
MAXDCS=] [,MSTXPMAXPCS=] [,RXLEVAMI=]
[,RDLNKTO=] [,RACHBT=] [,RACHLAS=] [,TCCCHLDI=]
[,PCCCHLDI=] [,FACCHQ=] [,CELLTYP=] [,BCCHFREQ=]
[,CALLF<nn>=] [,CCALL=] [,CRESPARI=] [,CRESOFF=]
[,TEMPOFF=] [,PENTIME=] [,CBQ=] [,NMULBAC=] [,CON-
CELL=] [,BTSHSCSD=] [,MAXRETR=] [,NSLOTST=]
[,NY1=] [,NBLKACGR=] [,NFRAMEPG=] [,MSTXPMAXCH=]
[,PWROFS=] [,ASCISER=] [,NOCHFBLK=] [,NOCHBLKN=]
[,INTCLASS=] [,INTAVEPR=] [,RFRSINDP=] [,CELL-
BARR=] [,CREALL=] [,NALLWACC=] [,EC=] [,SMSC-
BUSE=] [,DTXDLFR=] [,DTXDLHR=] [,DTXUL=]
[,IMSIATDT=] [,HOPP=] [,T3212=] [,PWROUT=] [,DIRT-
CHASS=] [,BMONTH=] [,BSMONTH=] [,EARCLM=] [,HOP-
MODE=] [,EXCDIST=] [,EEXCDIST=] [,EQ=] [,QLPUB=]
[,EPRE=] [,T200=] [,T3101=] [,T3105=] [,T3109=] [,T3111=]
[,TSYNC=] [,TSYNCUL=] [,TSYNCDL=] [,TSYNCR=]
[,TTRAU=] [,ENANCD=] [,NCDP1=] [,NCDP2=] [,TGRANT=]
[,NRPGRANT=] [,VGRULF=] [,TNOCH=] [,EHRACT=]
[,HRACTT1=] [,HRACTT2=] [,SDCCHCONGTH=] [,ASCI-
ULR=] [,TUPLREP=] [,EEOTD=] [,AMRFRC1=]
[,AMRFRTH12=] [,AMRFRC2=] [,AMRFRTH23=]
[,AMRFRC3=] [,AMRFRTH34=] [,AMRFRC4=]
[,AMRHRC1=] [,AMRHRTH12=] [,AMRHRC2=]
[,AMRHRTH23=] [,AMRHRC3=] [,AMRHRTH34=]
[,AMRHRC4=] [,AMRFRIC=] [,AMRHRIC=] [,AMRLKAT=]
[,FHAMRFRC1=] [,FHAMRFRTH12=] [,FHAMRFRC2=]
[,FHAMRFRTH23=] [,FHAMRFRC3=] [,FHAMRFRTH34=]
[,FHAMRFRC4=] [,FHAMRHRC1=] [,FHAMRHRTH12=]
[,FHAMRHRC2=] [,FHAMRHRTH23=] [,FHAMRHRC3=]
[,FHAMRHRTH34=] [,FHAMRHRC4=] [,FHAMRFRIC=]
[,FHAMRHRIC=] [,QSRHI=] [,FDDQMI=] [,FDDQO=]
[,QSRHCINI=] [,FDDREPQTY=] [,FDDMURREP=]
[,UMTSSRHPRI=] [,EANTHOP=] [,ANTHOPMOD=]
[,ANTHOPP=] [,GUARMABIS=] [,QSRHC=] [,TDDQO=]
[,TDDMURREP=] [,REPTYP=] [,ETXDIVTS=] [,TXDIVT-
SEXCPT=] [,TXDIVTSPAR=] [,TAADJ=] [,LCBM<n>=]
[,EHRACTAMR=] [,HRACTAMRT1=] [,HRACTAMRT2=]
[,FRACTTH1=] [,FRACTTH2=] [,FRACTAMRTH1=]
[,FRACTAMRTH2=] [,EPAT1=] [,EPAT2=] [,ENDMA=]
[,EAC=] [,ACFERMAX=] [,ACBQPMAX=] [,ACPER=]
[,ACLNKTYP=] [,ACBQPFF=] [,ACEFLFF=] [,ACMINE-
FLDMA=] [,ACMAXEFLDMA=] [,FRANOFFS=] [,BURN-
OFFS=] [,ENPERNOTDE=] [,PNOFACCH=] [,EHDCTR=]
[,MEAEXTBCCH=] [,SLLPRM=]


294 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SET BTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the configuration of a cell by specifying the global parameters
necessary for the creation. The attributes within this object describe the basic properties
of a BTS which are not related to the Common Control Channels.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
PLMNP plmnPermitted
CELLRESH cellReselectHysteresis
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
RXLEVAMI rxLevAccessMin
RDLNKTO radioLinkTimeout
RACHBT rachBusyThreshold
RACHLAS rachLoadAveragingSlots
TCCCHLDI thresholdCcchLoadIndication
PCCCHLDI periodCcchLoadIndication
FACCHQ facchQual
CELLTYP cellType
BCCHFREQ bcchFrequency
CALLF<nn> cellAllocationF<nn>
CCALL commonCellAllocation
CRESPARI cellReselectionParamInd
SET BTS [,CRTSWSPELLPRM=] [,AMRFRLLPRM=] [,AMRHRLL-
PRM=] [,CRTSWDLLPRM=] [,HSCSDLLPRM=] [,GLL-
PRM=] [,ELLPRM=] [,ASCILLPRM=]
[,CRTSWSPELLCOM=] [,AMRFRLLCOM=] [,AMRHR-
LLCOM=] [,CRTSWDLLCOM=] [,HSCSDLLCOM=]
[,GLLCOM=] [,ELLCOM=] [,DGRSTRGY=] [,LWWPSPRI=]
[,WPSPREF=] [,QLWPS=] [,GEXTS=] [,CSCE=]
[,CUCONF=] [,EFCRESEL=] [,FDDRSCPMI=] [,FDDQ-
MIO=] [,FDDREPTH=] [,FDDREPO=] [,TDDREPTH=]
[,TDDREPO=] [,FDDREPTH2=];


A30808-X3247-M230-6-7619

295
CML:BSC BTS
Id:0900d805800d4446
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
NMULBAC nMultibandcell
CONCELL concentricCell
BTSHSCSD btsHSCSD
MAXRETR maxNumberRetransmission
NSLOTST numberOfSlotSpreadTrans
NY1 ny1
NBLKACGR noOfBlocksForAccessGrant
NFRAMEPG noOfMultiFramesBetweenPaging
MSTXPMAXCH msTxPwrMaxCcch
PWROFS powerOffset
ASCISER advancedSpeechCallItemsService
NOCHFBLK notificationChannelFirstBlock
NOCHBLKN notificationChannelBlockNumber
INTCLASS enableInterferenceClass
INTAVEPR interferenceAveragingProcess
RFRSINDP rfResourceIndicationPeriod
CELLBARR cellBarred
CREALL callReestablishmentAllowed
NALLWACC notAllowedAccessClasses
EC emergencyCall
SMSCBUSE smsCBUsed
DTXDLFR dTxDownLinkFullRate
DTXDLHR dTxDownLinkHalfRate
DTXUL dTxUplink
IMSIATDT allowImsiAttachDetach
HOPP enableHopping
T3212 btsTimer3212
PWROUT powerOutputThresholds
DIRTCHASS directTchAssignment
BMONTH bintChanMonitorThresholds
BSMONTH bintSignChanMonitorThresholds
EARCLM enableEarlyClassmark
HOPMODE hoppingMode
EXCDIST excessiveDistance
EEXCDIST enableExcessiveDistance


296 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
EQ enableQueuing
QLPUB queuingLengthPublic
EPRE enablePreemption
T200 t200
T3101 btsTimer3101
T3105 btsTimer3105
T3109 btsTimer3109
T3111 btsTimer3111
TSYNC tSync
TSYNCUL tSynchronizationUplink
TSYNCDL tSynchronizationDownlink
TSYNCR tSynchronizationR
TTRAU tTrau
ENANCD enableNoCallDetection
NCDP1 noCallDetectionPeriod1
NCDP2 noCallDetectionPeriod2
TGRANT timerGrant
NRPGRANT numberRepetitionGrant
VGRULF voiceGroupUplinkFree
TNOCH timerNotificationChannel
EHRACT enableHrActivation
HRACTT1 hRActivationThreshold1
HRACTT2 hRActivationThreshold2
SDCCHCONGTH sdcchCongestionThreshold
ASCIULR asciUplinkReply
TUPLREP timerUplinkReply
EEOTD enableEOTD
AMRFRC1 aMRFullRateCodec1
AMRFRTH12 aMRFullRateThresholds12
AMRFRC2 aMRFullRateCodec2
AMRFRTH23 aMRFullRateThresholds23
AMRFRC3 aMRFullRateCodec3
AMRFRTH34 aMRFullRateThresholds34
AMRFRC4 aMRFullRateCodec4
AMRHRC1 aMRHalfRateCodec1
AMRHRTH12 aMRHalfRateThresholds12
AMRHRC2 aMRHalfRateCodec2
AMRHRTH23 aMRHalfRateThresholds23
AMRHRC3 aMRHalfRateCodec3


A30808-X3247-M230-6-7619

297
CML:BSC BTS
Id:0900d805800d4446
AMRHRTH34 aMRHalfRateThresholds34
AMRHRC4 aMRHalfRateCodec4
AMRFRIC aMRFullRateInitialCodec
AMRHRIC aMRHRInitialCodec
AMRLKAT aMRLinkAdapTuning
FHAMRFRC1 fhAMRFullRateCodec1
FHAMRFRTH12 fhAMRFullRateThresholds12
FHAMRFRC2 fhAMRFullRateCodec2
FHAMRFRTH23 fhAMRFullRateThresholds23
FHAMRFRC3 fhAMRFullRateCodec3
FHAMRFRTH34 fhAMRFullRateThresholds34
FHAMRFRC4 fhAMRFullRateCodec4
FHAMRHRC1 fhAMRHalfRateCodec1
FHAMRHRTH12 fhAMRHalfRateThresholds12
FHAMRHRC2 fhAMRHalfRateCodec2
FHAMRHRTH23 fhAMRHalfRateThresholds23
FHAMRHRC3 fhAMRHalfRateCodec3
FHAMRHRTH34 fhAMRHalfRateThresholds34
FHAMRHRC4 fhAMRHalfRateCodec4
FHAMRFRIC fhAMRFullRateInitialCodec
FHAMRHRIC fhAMRHRInitialCodec
QSRHI qSearchI
FDDQMI fddQMin
FDDQO fddQOffset
QSRHCINI qSearchCinitial
FDDREPQTY fddReportingQuantity
FDDMURREP fddMultiratReporting
UMTSSRHPRI umtsSearchPriority
EANTHOP enableAntennaHopping
ANTHOPMOD antennaHoppingMode
ANTHOPP antennaHoppingPeriod
GUARMABIS guaranteedMinimumAbis
QSRHC qSearchC
TDDQO tddQOffset
TDDMURREP tddMultiratReporting
REPTYP reportType
ETXDIVTS enableTxDivTimeShift
TXDIVTSEXCPT txDivTimeShiftExcept
TXDIVTSPAR txDivTimeShiftParam


298 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
TAADJ taAdjust
LCBM<n> localCellBroadcastMessage<n>
EHRACTAMR enableHRActivationAmr
HRACTAMRT1 hRActivationAmrThreshold1
HRACTAMRT2 hRActivationAmrThreshold2
FRACTTH1 fullRateActivationThreshold1
FRACTTH2 fullRateActivationThreshold2
FRACTAMRTH1 fullRateActivationAMRThreshold1
FRACTAMRTH2 fullRateActivationAMRThreshold2
EPAT1 enhancedPairingThreshold1
EPAT2 enhancedPairingThreshold2
ENDMA enableDMA
EAC enableAc
ACFERMAX acFERMax
ACBQPMAX acBQPMax
ACPER acPeriod
ACLNKTYP acLinkType
ACBQPFF acBQPFgtFac
ACEFLFF acEFLFgtFac
ACMINEFLDMA acMinEFLDMA
ACMAXEFLDMA acMaxEFLDMA
FRANOFFS frameNumberOffset
BURNOFFS burstNumberOffset
ENPERNOTDE enablePeriodicalNotifDedicatedChan
PNOFACCH periodNotificationFACCH
EHDCTR enableHistoryOnDroppedCallTrace
MEAEXTBCCH measureExtraBCCH
SLLPRM signallingLayerListPrimary
CRTSWSPELLPRM circuitSwitchedSpeechLayerListPrimary
AMRFRLLPRM aMRFullRateLayerListPrimary
AMRHRLLPRM aMRHalfRateLayerListPrimary
CRTSWDLLPRM circuitSwitchedDataLayerListPrimary
HSCSDLLPRM hscsdLayerListPrimary
GLLPRM gprsLayerListPrimary
ELLPRM edgeLayerListPrimary
ASCILLPRM asciLayerListPrimary
CRTSWSPELLCOM circuitSwitchedSpeechLLComp
AMRFRLLCOM aMRFullRateLayerListComplementary
AMRHRLLCOM aMRHalfRateLayerListComplementary


A30808-X3247-M230-6-7619

299
CML:BSC BTS
Id:0900d805800d4446
CRTSWDLLCOM circuitSwitchedDataLayerListComp
HSCSDLLCOM hscsLayerListComplementary
GLLCOM gprsLayerListComplementary
ELLCOM edgeLayerListComplementary
DGRSTRGY downgradeStrategy
LWWPSPRI lowestWPSPriority
WPSPREF wPSPreference
QLWPS queuingLengthWPS
GEXTS gprsExtension
CSCE cellScenario
CUCONF carrierUnitConfiguration
EFCRESEL enableFastCellReselection
FDDRSCPMI fddRscpMin
FDDQMIO fddQMinOffset
FDDREPTH fddReportThreshold
FDDREPO fddReportOffset
TDDREPTH tddReportThreshold
TDDREPO tddReportOffset
FDDREPTH2 fddReportThreshold2
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_BCCH_FREQUENCY
Make reference to Application Guidelines n. 9 and n. 17.
UNSUCCESSFUL_CELL_GLOB_ID
Make reference to Application Guidelines n. 1, n. 3, n. 10, n.68.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set. For more details
see Application Guidelines n. 2, n. 7, n. 11, n. 12, n. 15, n. 20, n.
24, n. 26, n. 30, n. 34, n. 35, n. 40, n. 41, n. 50, n. 54, n. 55, n. 63,
n. 64, n. 66, n. 67.
No more than 20 different combinations of (MCC-MNC-LAC-
RACODE) are permitted inside BSC.
No more than 20 different combinations of (MCC-MNC-LAC) are
permitted inside BSC.


300 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
The EHDCTR attribute can be set to TRUE only for BTS objects
belonging to BTSM objects having BR8.0 software version.
The attribute EAC can be set to TRUE only if ENDMA of BTS and
CBTS objects are set to TRUE.
To set the layer lists to change a SMA layer into a DMA layer and
viceversa, the DMA in the cell must be disabled.
The SSL attributes cannot contain empty layers, i.e. layers not
assigned to any equipped TRX: in order to assign a layer to a
service, at least one equipped TRX must belong to this layer in
LAYERID .
In a SLL attribute a layer cannot be replayed.
SLLPRM must always include LY0.
HSCSD service is not supported in far areas of extended cells: in
case of extended cell (CELLTYP=EXTCELL), HSCSDLLPRM
cannot be different from NULL.
GPRS and EDGE services are not supported in inner areas of
concentric cells: in case of concentric cell (CONCELL=TRUE),
GLLCOM and ELLCOM cannot be different from NULL.
The CRTSWSPELLCOM, AMRFRLLCOM, AMRHRLLCOM,
CRTSWDLLCOM, HSCSDLLCOM, GLLCOM, ELLCOM
attributes can be set at a value different from NULL only in case
of dual area cell (extended, concentric single/dual band).
In order to set the flag ASCISER to TRUE, the ASCILLPRM
attribute must contain at least LY0 (in first position).
The flag BTSHSCSD cannot be TRUE if both HSCSDLLPRM and
HSCSDLLCOM are set at NULL
If the BCCH TRX contains GPRS control channels (PBCCH,
PCCCH), its Layer (LY0) must be assigned at least to GPRS
service in case of TRXMD=GSM, at least to EDGE service in case
of TRXMD=EDGE, or to both services.
In concentric cells, every layer assigned to the primary and the
complementary service layer lists for each service must contain at
least one TRX belonging to the related area.
TRXs containing signalling channels(including TCHSD channels
with TCHSD or SDCCH pool) must belong to layers assigned to
the signalling service.
In order to enable DIRTCHASS, the layers of service SLLPRM
must go from more to less shared.
The primary service layer lists related to AMR FR and AMR HR
services must contain the same layers.
The complementary service layer lists related to AMR FR and
AMR HR services must contain the same layers.


A30808-X3247-M230-6-7619

301
CML:BSC BTS
Id:0900d805800d4446
The primary service layer list related to HSCSD, GPRS and
EGPRS service must have the dedicated layer of primary area in
first position.
The complementary service layer list related to HSCSD, GPRS
and EGPRS service must have the dedicated layer of comple-
mentary area in first position.
In dual band standard cells, the ASCILLPRM must contain layer
with at least one TRX with the frequency belonging to the band of
BCCH.
The attribute DGRSTRGY cannot be set to
HSCSD_FIRST_DOWNGRADE or
DOWNGRADE_HSCSD_ONLY if the attribute MADGRLV (BSC
object) is set to 0.
The attributes FRANOFFS and BURNOFFS cannot be set if
"Inter-Site Synchronization" is enabled.
With attribute HOSYNC equal SYNC (BSC object), the value of
BURNOFFS must be equal to the value of other cells of site.
When QLWPS assumes value 0, the attribute LWWPSPRI must
be NULL, while if QLPWPS assumes a values between 1..100 the
attribute LWWPSPRI mus assume a value between 1..10.
The value DBSTDCELL for the CELLTYP attribute is not accepted
if the CONCELL parameter is set at TRUE.
The GEXTS attribute can assume value ALL900 on a BTS with
SYSID GSMDCS if BCCHFREQ isn't in the range (512-885).
The GEXTS can be set to ALLFREQ only if CELLTYP is set to
DBSTDCELL.
The GEXTS can be set to ALL900 only if SYSID is EXT900 or
GSMDCS.
For SYSID different by EXT900, GSMDCS, GSM850DCS and
GSM850PCS the only GEXTS value permitted is NULL.
The GEXTS attribute must be set to NULL if SYSID is EXT900
and BCCH is the extended band.
If GEXTS attribute is different by NULL, SYSID equal EXT900 or
GSMDCS and BCCH in the range (1-124), the channels SDCCH,
SCBCH and TCHSD with pool type SDCCH or TCHSD cannot be
hopp.
REPTYP attribute must be activated to have ACLNKTYP different
by UL_SAMPLE_ONLY.
In case of Base Band Hopping you cannot have CCALL different
by NULL value.
All cells with ENDMA and enableInterSiteSync enabled must have
same frameNumberOffset.
All cells with ENDMA and enableInterSiteSync enabled must have
same burstNumberOffset.


302 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
In dual band cells, the SLLPRM or SLLCOM must contain at least
one TRX per layer with the frequency belonging to the related
band.
The dedicated layer in each area must be in first position.
The EGPRS flag in PTPPKF object cannot be TRUE if both
GLLPRM and GLLCOM are set at NULL.
In order to set the CUCONF parameter the BTS must be locked.
EDTMSUP can be enabled only if at least one layer is shared
between signalling (signallingLayerList), circuit (circuitSwitched-
SpeechLayerList or aMRFullRateLayerList or aMRHalfRate-
Layer-List) and packet (gprsLayerList or edgeLayerList) services.
CELLTYP cannot be set to EXTCEL if the subordinated PTPPKF
has the EDTMSUP enabled.
EDTMSUP cannot be enabled when EARCLM is disabled.
UNSUCCESSFUL_EQUAL_FREQ
The attribute CALLF<nn> must not contain twice the same fre-
quency and it must not contain the frequency entered in the
attribute BCCHFREQ.
The attribute CCALL must not contain twice the same frequency
and it must not contain the frequency entered in the attribute
BCCHFREQ and in the attribute CALLF.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE
Make reference to Application Guidelines n. 4 and n. 52.
The frequencies present into CCALL must be compatible with
SYSID of the cell.
The frequencies present into CCALL must belong to CBTS.
If BCCHFREQ attribute is in the range (0. 301-424, 975-1023) the
CALLFx cannot be set to a frequency (1-124).
With SYSID attribute of BTS is EXT900 or GSMDCS, the BCCH
band cannot change from P to G1_GSM band and viceversa.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Make reference to Application Guidelines n. 5, n. 14, n. 18, n. 19,
n. 22, n. 23, n. 31, n. 39, n. 42, n. 43, n. 44.
In the attribute WPSPREF, if the subfield numberWPS assumes
value 2, the minimum value of the subfield counterCycle must be
at least 3, while if numberWPS is set to 3, the counterCycle must
be at least 4.
UNSUCCESSFUL_INVALID_STATUS
Make reference to Application Guidelines n. 6, n. 36, n. 37, n. 62.
The TRX associated to DMA layer must be locked to set ENDMA
to FALSE.


A30808-X3247-M230-6-7619

303
CML:BSC BTS
Id:0900d805800d4446
With HW version different by BTSplus or BS 240 XS the attributes
FRANOFFS and BURNOFFS cannot be set.
To set GEXTS parameter, the object must be in "Locked" state.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
Make reference to Application Guidelines n. 8, n. 13, n. 25.
The attribute HOPMODE (hoppingMode) can be set if there are
no subordinate channels or TRXs that point to a CFHSY object.
In order to set GLLPRM/GLLCOM and ELLPRM/ELLCOM
attributes, the PTPPKF subordinated to the BTS object must be
locked.
HSCSD_HOPP_INCONSISTENT
The attribute BTSHSCSD can be set to TRUE only if the following
requirements are satisfied:
1) Case Base Band Hopping Mode:
on every TRX belonging to the layers contained in HSCSDLL-
PRM/HSCSDLLCOM, single TCHs on timeslot from 1 to 7 must
have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in HSCSDLL-
PRM/HSCSDLLCOM, different from the BCCH one, all single
TCHs must have the same FHSYD and MAIO.
TIMER_EXPIRED
The BCCH change procedure is failed for time out.
INVALID_SVR
BS-242 cannot support extended and concentric cells.
BS-242 cannot support base band hopping (HOPMODE of BTS
object).
The AMRHRCi/FHAMRHRCi attribute can not be set at value
RATE_05 (7.40 kbit/s) if the SW version running on the superor-
dinate BTSM belongs to BR6.0 release (see EXPSWV parameter
description).
The attributes EAC, ACFERMAX, ACBQPMAX, ACPER, ACLNK-
TYP, ACBQPFF, ACEFLFF, ACMINEFLDMA and ACMAXE-
FLDMA must assume a value different by NULL for SW_ver
greater or equal than BR8.0 and HW_ver equal to BTS_plus or
BS240 XS, and viceversa.
With HW version different by BTSplus or BS 240 XS the attributes
FRANOFFS and BURNOFFS cannot be set.


304 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
BCCF_AND_BSIC_BELONG_TO_ANOTHER_CELL
The serving and target adjacent cells cannot have the same
BCCH-BSIC pair.
INVALID_COMMAND
The frequency hopping can be enabled only if there are some
CHANs or TRXs using a frequency hopping law different from
FHSY0. The frequency hopping can only be enabled if the fre-
quency belonging to a superordinate TRX of a non-hopping
channel is not used in a frequency hopping system assigned to an
hopping channel instance with the same timeslot number.
To change the value of ENDMA, the DMA in the site must be dis-
abled.
To set HOPP to FALSE the DMA in the cell must be disabled.
UNSUCCESSFUL_CBCH_NOTEQUIPPED
To set SMSCBUSE at TRUE it is required that CBCH (BCBCH or
SCBCH) channel is already created. Before deletion of a created
CBCH, SMSCBUSE has to be set at FALSE.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
The frequency hopping can be enabled only if there are no
channel instances with the same time slot using two different fre-
quency hopping systems with the same common frequency.
The frequency hopping can only be enabled if the frequency
belonging to a superordinate TRX of a non-hopping channel is not
used in a frequency hopping system assigned to a hopping
channel instance with the same timeslot number.
In case of extended cell make reference to Application Guideline
n. 28.
If the cell has at least one channel that uses a CFHSY, the fre-
quency hopping law can be enabled or disabled only with DMA
disabled in the site.
HSCSD_TSC_INCONSISTENT
Make reference to Application Guidelines n. 16 and n. 29.
UNSUCCESSFUL_FREQUENCY_UNDER_MEASURE
The BCCH frequency cannot be changed if the BTS is the target
cell of an ADJC which has its BCCH frequency traced by the
relative SCA (see NMDLATT<nn> parameters).
UNSUCCESSFUL_MIXED_CELL_NOT_CONCENTRIC_CELL
If the SYSID parameter equals either to GSMDCS, GSM850PCS
or GSM850DCS the CONCELL parameter must be set at TRUE
only for standard cells.
UNSUCCESSFUL_FREQUENCY_CHANGE_NOT_ALLOWED


A30808-X3247-M230-6-7619

305
CML:BSC BTS
Id:0900d805800d4446
In a GSMDCS mixed cell and in a GSM850PCS cell it is not
possible to change a frequency value from one band of the cell to
the other if the frequency is already assigned to a TRX; this is due
to the fact that the hardware of a TRX is not able to manage two
different frequency bands.
INVALID_RATE
Make reference to Application Guidelines n. 45, n. 46, n. 47, n. 48,
n. 49.
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The maximum number of frequencies that can be assigned to a
cell has been reached. For more details see Application Guideline
n. 38.
The sum of frequencies in a cell is major of 64.
UNSUCCESSFUL_FREQ_IN_USE
A frequency can be removed only if it is not in use by any TRX or
FHSY.
A frequency belong to CCALL can be removed only if it is not in
use by any TRX.
The frequencies into CCALL cannot be removed if they are used
by an hopping law that is pointed by BTS.
UNSUCCESSFUL_OVERLAP_BAND
When SYSID is equal to GSMDCS, EXT900 or GSM850PCS, if
the frequencies belonging to the MOBALLOC are changed, the
new set of frequencies must remain in the same sub-band.
MAX_ADJC_COMPL_BAND_EXCEEDED
The number of adjacent cells having their BCCHFREQ in the
complementary band exceeds the allowed maximum number.
For more details, see Application Guideline n. 53.
UNSUCCESSFUL_INVALID_BCCF
The serving and target adjacent cells cannot have the same
BCCH frequencies when the target cell is different from the
serving cell.
INCOMP_NESWLOAD_VS_MESSAGE
The EANTHOP, ANTHOPMOD and ANTHOPP parameters
cannot be set at NULL value if the RR sub-field of the EXPSWV
parameter (see the parameter description) of the superordinate
BTSM object is equal or greater than 15.
The EANTHOP, ANTHOPMOD and ANTHOPP parameters must
be set at NULL value if the RR sub-field of the EXPSWV parame-
ter (see the parameter description) of the superordinate BTSM
object is less than 15.
The EANTHOP, ANTHOPMOD and ANTHOPP attributes are
supported only by BS-240, BS-240XS and BS-82.


306 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
The ETXDIVTS can not be set at TRUE if the SW version running
on the superordinate BTSM belongs to BR6.0 release (see
EXPSWV parameter description).
The ETXDIVTS can not be set at TRUE if the superordinate BTSM
is of type BS-20, BS-21, BS-22, BS-60, BS-61, BS-82, BS-242.
The GUARMABIS attribute must have NULL value if the SW
Version running on the superordinate BTSM object belongs to
BR6.0 release (see EXPSWV parameter description).
The GUARMABIS attribute cannot be set at NULL value if the SW
Version running on the superordinate BTSM object belongs to
BR7.0 release (see EXPSWV parameter description).
The REPTYP attribute can be set at ENHANCED value only if the
SW Version running on the superordinate BTSM belongs to
BR7.0 release (see EXPSWV parameter description).
The TAADJ attribute must have NULL value if the SW Version
running on the superordinate BTSM belongs to BR6.0 release
(see EXPSWV parameter description).
The TAADJ attribute cannot be set at NULL value if the SW
Version running on the superordinate BTSM belongs to BR7.0
release (see EXPSWV parameter description).
If the superordinate BTSM SW is less than BR8.0, ENPER-
NOTDE and PNOFACCH attributes must assume the NULL
value.
The ENPERNOTDE and PNOFACCH attributes cannot be set to
NULL, if the superordinate BTSM SW is greater or equal than
BR8.0.
The MEAEXTBCCH attribute can be set to TRUE only if the
superordinate BTSM has a SW version>=8.0.
The attributes FRANOFFS and BURNOFFS cannot assume
value different by NULL for SW version less than BR8.0, and vice-
versa.
The CELLTYP attribute can assume DBSTDCELL value if the SW
version running on the superordinate BTSM object belongs to
BR8.0 release.
For CUCONF parameter values different from the default (homo-
geneous) are allowed only for BTSplus mainline (hh=04, ii=01)
and BS240XS (hh=04, ii=06).
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE


A30808-X3247-M230-6-7619

307
CML:BSC BTS
Id:0900d805800d4446
The maximum number of different frequencies of
adjacent cells that can be included in System
Information 5 is:
- 30, if LOTRACH=FALSE in HAND object and
one or more ADJC3Gs are equipped;
- 31, if LOTRACH=FALSE in HAND object and no
ADJC3Gs are equipped;
- 31, if LOTRACH=TRUE in HAND object and one
or more ADJC3Gs are equipped.
-32, otherwise.
DMA_NOT_SUPPORTED
To have ENDMA to TRUE, at least one layer must exist which is
reserved for one or more of the following services: CS Speech
EFR-FR-HR, CS Speech AMR-FR, CS Speech AMR-HR and
each one of these reserved layers must point to a different
CFHSY.
The ENDMA can be set to TRUE if BTS point to a CFHSY.
The ENDMA can be set to TRUE if CCALL is different by NULL.
An extended cell or concentric cell cannot have ENDMA set to
TRUE.
The ENDMA can be set to TRUE if HOPP is enabled and
HOPMODE is SYNHOP.
The ENDMA cannot be set to TRUE if the layer TRXs can remove
all frequencies by the list of MAIO.
To enable the DMA, the TRXs on the future DMA layer must have
FHSYID different by NULL.
To set ENDMA to TRUE, two TRXs that point to different CFHSY
cannot have the same layer.
To set ENDMA to TRUE, a TRX that point to a FHSY cannot have
the same layer of a TRX that point to CFHSY.
To the qualification of DMA, the number of frequencies contained
into CMOBALLOC attribute of CFHSY pointed by BTS, must be
major or equal to the minor number of MAIOs available for DMA.
GPRS_TSC_INCONSISTENT


308 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
If the EGPRS flag is set to TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode:
on every TRX belonging to the layers contained in GLL-
PRM/GLLCOM, single TCHs on timeslot from 1 to 7 must have the
same TSC.
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in GLL-
PRM/GLLCOM all single TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
If the DTMSUP flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area, single TCHs on timeslot from 1 to 7 must have the
same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area all single TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
GPRS_HOPP_INCONSISTENT


A30808-X3247-M230-6-7619

309
CML:BSC BTS
Id:0900d805800d4446
If the EGPRS flag is set to TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode:
on every TRX belonging to the layers contained in GLL-
PRM/GLLCOM, single TCHs on timeslot from 1 to 7 must have the
same FHSY and MAIO. If at least one CCCH has already been
equipped, the MOBALLOC of the FHSY object instance cannot
contain the BCCH frequency and all channels on the BCCH-TRX
cannot hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in GLL-
PRM/GLLCOM, different from the BCCH one, all single TCHs
must have the same FHSYD and MAIO.
If the DTMSUP flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet Services
in Primary area, single TCHs on timeslot from 1 to 7 must have the
same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet Services
in Primary area, different from the BCCH one, all single TCHs
must have the same FHSYD and MAIO.
EDGE_TSC_INCONSISTENT
If the EEDGE flag is set to TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode:
on every TRX belonging to the layers contained in ELL-
PRM/ELLCOM, single TCHs on timeslot from 1 to 7 must have the
same TSC.
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in ELL-
PRM/ELLCOM, all single TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
EDGE_HOPP_INCONSISTENT


310 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Application Guidelines:
1. The cellGlobalIdentity (MCC, MNC, LAC, CI) must be set at the following
combination:
If the EEDGE flag is set to TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode:
on every TRX belonging to the layers contained in ELL-
PRM/ELLCOM, single TCHs on timeslot from 1 to 7 must have the
same FHSY and MAIO. If at least one CCCH has already been
equipped, the MOBALLOC of the FHSY object instance cannot
contain the BCCH frequency and all channels on the BCCH-TRX
cannot hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in ELL-
PRM/ELLCOM, different from the BCCH one, all single TCHs
must have the same FHSYD and MAIO.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The service layer list related to GPRS and EGPRS service cannot
be different by NULL if the PTPPKF is not equipped.
The object CBTS must be equipped to set attribute CCALL differ-
ent by NULL.
UNSUCCESSFUL_EDGE_ENABLED
In order to set the flag EEDGE to TRUE in PTPPKF object, every
layer assigned to the primary/complementary layer list of EDGE
service (ELLPRM and ELLCOM attributes of the BTS object) must
contain:
- at least one TRX with TRXMD=EDGE, if the layer is not exclu-
sive for EDGE
- all the TRXs with TRXMD=EDGE, if the layer is exclusive for
EDGE
ELLPRM and ELLCOM cannot be both set at NULL if the flag
EDGE in PTPPKF object is TRUE.
UNSUCCESSFUL_GPRS_ENABLED
GLLPRM and GLLCOM cannot be both set at NULL if the flag
EGPRS in PTPPKF object is TRUE.
INVALID_NETWORK_IDENTIFIER
The attribute CELLTYP cannot assume value DBSTDCELL with
SYSID different by GSMDCS, GSM850DCS and GSM850PCS.
MCC, MNC, LAC, CI
where:
Location Area Identity (LAI) = MCC + MNC + LAC


A30808-X3247-M230-6-7619

311
CML:BSC BTS
Id:0900d805800d4446
2. Three attributes in the BTS Managed Object are formatted in digits; the attributes
are:
the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained
in the CellGlobalId (CELLGLID);
the bSIdentityCode (BSIC);
3. The "cellGlobalIdentity" (MCC, MNC, LAC, CI) must be different from the
"cellGlobalIdentity" of all the other BTSs of the BSC.
Cell Global Identity = LAI + CI
If one field is skipped it assumes the OLD value.
CELLGLID = MCC-MNC-LAC-CI
Note that
MCC = D1D2D3
MNC = D1D2D3
Dx means digit (only numerical characters shall be used; for numbers
from 0 to 9 it must be entered one digit). In fact 9 is different from 09.
For MCC all digits are mandatory while for MNC D1 AND D2 are
mandatory.
BSIC = D1D2
Dx means digit (only numerical characters 0..7 shall be used)
Note that D1 is the NetworkColourCode (NCC) and D2 is the
BTSColourCode (BCC)
This attributes are stored in the system in their decimal representation
(which is the input format) but it is necessary to check the range of each
digit:
MCC, MNC 0 =< Dx =< 9
BSIC 0 =< Dx =< 7
Do not configure cells without giving a value to the parameter
Cell Identifier (CI) of the Cell Global Identifier attribute belonging to the
BTS BASICS group because such cells are not handled by the system.


312 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
4. The frequencies set to CALL (cellAllocation) attribute must follow these rules:
For the US market (PCS1900 and the PCM24) the following frequency blocks are
defined:
The following considerations are valid only for the US market, if SYSID = PCS1900:
all the frequencies of the CALLF (cellAllocation) must belong to one of the allowed
frequencies; in particular, the maximum RF output power for the corner frequencies
(512 and 810) is reduced of a fixed quantity, depending on the CU type. The table
below shows the amount of the reduction for different kinds of CUs.
if SYSID = BB900 then 1 =< frequency =< 124
if SYSID = EXT900 then 0 =< frequency =< 124
975 =< frequency =< 1023
if SYSID = DCS1800 then 512 =< frequency =< 885
if SYSID = GSMR then 955 =< frequency =< 974
if SYSID = PCS1900 then 512 =< frequency =< 810
if SYSID = GSMDCS then 0 = < frequency =< 124 and
975 = < frequency =< 1023 (GSM
extended band)
512 =< frequency =< 885 (DCS 1800)
If SYSID = GSM850 then 128 =< frequency =< 251
If SYSID = GSM850PCS then 128 =< frequency =< 251
512 =< frequency =< 810
If SYSID = GSM850DCS then 128 =< frequency =< 251 (GSM 850)
512 =< frequency =< 885 (DCS 1800)
from 512 to 585 for A block
from 587 to 610 for D block
from 612 to 685 for B block
from 687 to 710 for E block
from 712 to 735 for F block
from 737 to 810 for C block
CU type ARFCN 512 reduction ARFCN 810 reduction
ECUPHPV3 8 dB 6 dB
ECUPHPV4 8 dB 6 dB
ECUPV2 4 dB 2 dB
GCUPV1 4 dB 2 dB
CUPV4 4 dB 4 dB


A30808-X3247-M230-6-7619

313
CML:BSC BTS
Id:0900d805800d4446
5. For the different SYSID setting, the following "msTxPwrMax" parameters must be
used:
If SYSID equals BB900, EXT900, GSMDCS, GSMR, GSM850, GSM850PCS or
GSM850DCS the MSTXPMAXGSM must be set.
If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS
must be set.
If SYSID equals PCS1900 or GSM850PCS the MSTXPMAXPCS must be set.
If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSM must be set
at 2..15 (for the GSM part of the cell), and the MSTXPMAXDCS must be set at
0..15 (for the DCS part of the cell).
If SYSID equals GSM850PCS the MSTXPMAXGSM must be set at 2..15 (for the
GSM part of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31
(for the PCS part of the cell).
6. The BSIC (bsIdentityCode) and the CELLGLID (cellGlobalIdentity) attribute can be
set if the BTS object is LOCKED:
if the administrative state is LOCKED the command is accepted;
if the administrative state is UNLOCKED the command is not accepted.
7. If CRESPARI=0 --> CRESOFF, TEMPOFF, PENTIME, CBQ are skipped.
If CRESPARI=1 --> CRESOFF, TEMPOFF, PENTIME, CBQ are not skipped.
8. The attribute CONCELL can be set only if no subordinated TRXs are equipped.
9. In case of synthesizer frequency hopping (HOPMODE attribute in BTS object), the
BCCFREQ (broadcast frequency of the cell) cannot be included in a frequency
hopping system.
10. The CELLGLID cannot be equal to the CELLGLID of an equipped subordinated
ADJC (internal or external).
11. In order to change the frequencies of the cell no other attribute can be modified at
the same time.
12. The value EXTCELL of cellType attribute is not accepted if the value of the concen-
tricCell attribute is TRUE.
13. The cellType attribute can be changed from EXTCELL to STDCELL, and viceversa,
only if all subordinated channels are deleted.
14. When the cellType attribute changes from EXTCELL to STDCELL, the value of the
attribute excessiveDistance must be in narrow range 1..35 km.
In case of Standard (Not Extended) Cell, the value of the attribute EXCDIST must
be in range 1..35 km.
15. The HSCSD service can be activated in the cell (BTSHSCSD set at TRUE) only if
the HSCSD service is activated at BSC side (ENHSCSD attribute of BSC is set at
TRUE).
16. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS
object set at TRUE) the following TSC requirements must be satisfied:


314 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Case Base Band Hopping Mode: on every TRX belonging to the layers con-
tained in HSCSDLLPRM/HSCSDLLCOM, single TCHs on timeslot from 1 to 7
must have the same TSC.
Case Synthesizer Hopping Mode: on every TRX belonging to the layers con-
tained in HSCSDLLPRM/HSCSDLLCOM all single TCHs must have the same
TSC.
The command is rejected if some TSCs are set at the same value and the others are
skipped.
17. In case of GSMDCS, GSM850PCS or GSM850DCS cells, the band of the BCCH fre-
quency cannot be changed.
18. If the MBCCHC or BCBCH channel type is configured (see CHAN object) then the
NBLKACGR attribute must not be higher than 2.
19. If the SCBCH channel type is configured (see CHAN object) then the NBLKACGR
attribute must not be equal to 0.
20. To enable ASCISER, the NBLKACGR must be greater than NOCHBLKN.
It is possible to enable ASCISER following the indications described in the next
table:
In case of not created channel please refer to MAINBCCH channel type case.
21. When Abis satellite links are used, due to introduction of additional delays between
MS channel requests and BSC immediate assignment commands, the probability of
repeated requests from MS is increased depending on the value of the parameter
NSLOTST.
The NSLOTST value corresponding to a max waiting time before retransmission of
the CHANNEL REQUEST is recommended. Additional SDCCHs are recommended
to prevent congestion due to retransmission.
NOCHFBLK NOCHBLKN Channel Type (CHTYPE)
1..4 1..4
5 1..3 MAINBCCH
6 1..2
7 1
1..3 1 MBCCHC or BCBCH


A30808-X3247-M230-6-7619

315
CML:BSC BTS
Id:0900d805800d4446
22. When the interference classification of idle traffic channels is enabled (INTCLASS
attribute) the following attributes are relevant:
The values of the interference boundaries are strictly increasing (00 <= x1 < x2 <
< x3 < x4 < 63, where xn = intThrBoun).
x1, x2, x3 and x4 constitute the right boundaries of the interference bands they
belong to.
Example:
x1 = 00 dBr (<= -110 dBm):
x2, x3, x4 have fixed values as follows:
x2 = 03 dBr (<= -107 dBm)
x3 = 61 dBr (<= -49 dBm)
x4 = 62 dBr (<= -48 dBm)
interference band 1 (dBm): -..<= -110
interference band 2 (dBm): -110 <...<= -107
interference band 3 (dBm): -107 <...<= -49
interference band 4 (dBm): -49 <...<= -48
interference band 5 (dBm): -48 <...<= +
All boundaries are coded as binary representation of -X dBm decimal values.
For the values make reference to Appendix B: Group 2.
23. For the attributes BMONTH and BSMONTH the following relationship must be sat-
isfied for the fields minor, major, critical:
minor < major < critical.
24. For the attributes BMONTH and BSMONTH, regarding the flags minor, major,
critical and the relative threshold attributes, note that:
if the flags are set at ENABLE the threshold values cannot be skipped;
if the flags are set at DISABLE the threshold values must be skipped;
if the flags are skipped also the threshold values must be skipped.
25. The attribute HOPMODE (hoppingMode) can be set only if there are no subordinate
frequency hopping systems equipped.
26. If the excessive distance is enabled (EEXCDIST= TRUE), the value assigned to the
attribute EXCDIST must be greater than the value assigned to the distance
handover thresholds:
hoThresholdMsRangeMax - attribute HOTMSRM of HAND object (in case of
standard cell);
hoThresholdMsRangeMax - attribute HOTMSRME of HAND object (in case of
extended cell).
averagingPeriod INTAVEPR
interferenceThresholdBoundaries INTAVEPR
rfResourceIndicationPeriod RFRSINDP


316 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
27. If the excessive distance is enabled (EEXCDIST=TRUE) the following attribute is
relevant:
excessiveDistance - EXCDIST attribute of HAND object.
The value assigned to the attribute EXCDIST must be greater than the value
assigned to the distance handover thresholds:
hoThresholdMsRangeMax - attribute HOTMSRM of HAND object (in case of
Standard Cell and Dual Band Standard Cell);
hoThresholdMsRangeMax - attribute HOTMSRME of HAND object (in case of
Extended Cell).
28. The extended channels use two consecutive timeslots: therefore, in case of
extended cell, all the previous Application Guidelines regarding frequency hopping
consistency apply also to the timeslot following the channel timeslot.
29. If the HSCSD service is activated at BTS side (i.e. attribute BTSHSCSD of BTS is
set at TRUE) the HOPMODE can be set from BBHOP to SYNHOP only if in the cell
the single TCHs on radio timeslot 0 have the same TSC of all the other single TCHs
belonging to the superordinated TRX.
30. In order to enable the HSCSD service, the EARCLM attribute must be previously set
at TRUE.
31. If EPRE parameter is set at TRUE value the timer BSCT7 of the SET BSC command
must be set at a value between 6 and 254.
32. Within GSM Rec. 04.08, timer T3107 is specified for supervision of receipt of
handover complete response assignment complete. In addition two timers with the
same task are specified for BSSMAP, namely BSCT8 and BSCT10 (see BSC
object). To make easier the handling of these timers only two of them are used within
SBS. There is no lack in supervision of above named messages due to this imple-
mentation, neither for internal nor for external handover procedures.
33. The timers TSYNC and TTRAU must be set longer than ALARMT2 (see LICD
object). The timers TSYNC and TTRAU must be set longer than BSCT10 (see BSC
object) and BSCT8 (BSC object). This is to ensure that a signalling failure (BSCT8
and BSCT10) is detected before a transcoder failure (TSYNC and TTRAU).
The attribute TSYNC should be equal to TTRAU attribute.
34. For the attribute NCDP2, the TimerNoCall2 field can be set only if the StarTime2
field is different from NOTUSED.
35. If the second time-frame is configured by the NCDP2 setting, the StartTime2 value
must be greater than the StartTime1 field of NCDP1 attribute.
If the second time-frame is configured by the NCDP2 setting, the following configu-
ration rule must be satisfied:
36. In order to set BCCHFREQ, CELLGLID, BSIC, CALLF<nn>, CCALL parameters,
the relative SCA object must be in "Locked" state.
a whole observation period must be present within each time-frame,
i.e. TimerNoCall1 <= 6*(StartTime2 - StartTime1)
TimerNoCall2 <= 6*((24 - (StartTime2 - StartTime1))
The two time-frames must be converted in periods of ten minutes.


A30808-X3247-M230-6-7619

317
CML:BSC BTS
Id:0900d805800d4446
37. In order to set the CELLGLID attribute, if the BTS is referred as adjacent of a BTS
for which a SCA has been created, the SCA must be locked.
38. The maximum number of frequencies that can be assigned to a cell depends on the
delta between the lowest and the highest frequency given to the CALLFn and
CCALL attributes, as shown in the following table.
39. The ASCIULR attribute cannot be set at VBSENABLE, VGCSENABLE or
VBC_VGCSENABLE if the ASCISER attribute is set at ASCI_DISABLED.
40. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS, MSTXPMAXPCS can
be set only if the SYSID refers to the corresponding band; otherwise they must be
skipped or assume the value <NULL>.
41. It is not possible to change more AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi)
attributes at the same time.
42. It is not possible to set all AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi)
attributes at NULL; at least one value must be configured.
43. The following relations between the Threshold (TH) and Hysteresis (HYS) fields of
two adjacent Codecs must be satisfied when the value of the AMRFRCi/FHAMR-
FRCi (AMRHRCi/FHAMRHRCi) attribute is changed:
TH(i-1) <= TH(i) <= TH(i+1) i = 2,3
(TH + HYS)(i-1) <= (TH + HYS)(i) <= (TH + HYS)(i+1)
44. The AMRFRCij/FHAMRFRCij (AMRHRCij/FHAMRHRCij) attribute can be set at
NULL value only if the AMRFRCj/FHAMRFRCj (AMRHRCj/FHAMRHRCj)) attribute
is already set at NULL.
45. The value of the AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi)) attribute must
be smaller than the value of the AMRFRCi+1/FHAMRFRCi+1 (AMRHRCi+1/FHAM-
RHRCi+1) attribute.
46. If the AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi) attribute is not configured,
also all the subsequent AMRFRCj/FHAMRFRCj (AMRHRCj/FHAMRHRCj)
attributes have not to be configured (j > i).
47. The attribute AMRFRCi/FHAMRFRCi can not be set at value RATE_04 or RATE_05
for BSs 2x/6x.
48. The AMRFRIC/FHAMRFRIC (AMRHRIC/FHAMRHRIC) attribute must not be equal
to CODEC_MODE_i value if the AMRFRCi/FHAMRFRCi (AMRHRCi/FHAMRHRCi)
attribute is set at NULL value.
49. The flag EEOTD cannot be set at TRUE if existing channels on bcch trx have TSC
different from NULL.
N. max Freq. Delta
16 Any
17 Any if freq.0 is present
18 512
22 256
29 128
64 111 or frequency in BB900 band


318 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
50. The new BCCH frequency must not be used by any of the adjacent cells.
51. In case of EXT900, if any subordinate TRX has some signalling channel subordi-
nated then its carrier frequency must be in the range 1..124.
52. Frequencies can be changed if all the hopping laws involved do not have CHAN
instances that point to them.
53. The maximum number of adjacent cells having their BCCHFREQ in the complemen-
tary band, with respect to the SYSID of the serving cell, depends on the delta
between the lowest and the highest frequency of the ADJC belonging to this subset,
as shown in the following table.
54. The HOPMODE (hoppingMode) attribute can not be set at BBHOP (baseband
hopping) if Antenna Hopping is enabled.
55. The EANTHOP (enableAntennaHopping) attribute can be enabled only if the HOPP
(enableHopping) attribute is set at TRUE and the HOPMODE value is different from
BBHOP.
56. If the cell load dependent activation of Half Rate channels is enabled (by means of
EHRACT parameter) in a cell configured as Extended or Concentric, the following
rule applies: if no channels have been configured as TCHF_HLF (see CHTYPE
parameter of CHAN object) in the Near/Inner area and a new request comes for an
Half Rate channel to be assigned into the Near/Inner area, the system first tries to
assign a Full Rate channel into this area. If there are no available channels into the
Near/Inner area, the system assigns a Full Rate channel into the Far/Complete area
(even though TCHF_HLF channels have been configured in the Far/Complete
area).
57. In case of request with channel rate Full the pre-emption (which is enabled by
means of EPRE parameter) is allowed only to vulnerable calls that are allocated on
Full Rate channels. No preemption of Half Rate calls is performed. This restriction
is due to impossibility, with actual implementation, to be sure that after pre-emption
procedure the other part of the channel is still available.
58. LCBMx attributes can be set at a value different from NULL only if no CBCL
instances have been already equipped.
59. The EANTHOP parameter can not be set at TRUE if the ETXDIVTS parameter is
set at TRUE.
60. If the ETXDIVTS parameter is set at TRUE the HOPP parameter can be set at TRUE
only with HOPMODE = SYNHOP.
Max Number of ADJC in
complementary Band
Delta
16 Any
17 Any, if frequency 0 is present
18 512
22 256
29 128
All 111 or frequency in BB900 band


A30808-X3247-M230-6-7619

319
CML:BSC BTS
Id:0900d805800d4446
61. The HOPMODE parameter can not be set at a value different from SYNHOP if the
ETXDIVTS parameter is set at TRUE.
62. The ETXDIVTS, TXDIVTSEXCPT, TXDIVTSPAR parameters can be set only if the
BTS object is in LOCKED state.
63. The ETXDIVTS parameter can be set at TRUE only if (EANTHOP = FALSE and
HOPP = FALSE) or (HOPP = TRUE and HOPMODE = SYNHOP).
64. The sum of the GUARMABIS attributes for the BTSs belonging to the same BTSM
must be less or equal to 70.
65. The AMRHRCi attribute can be set at value RATE_05 (7.40 kbit/s) only if the BTS
HW version is BTSplus.
66. The FDDREPQTY attribute cannot be set at Ec_No if the EUIMPHO
attribute (see HAND object) is set at True.
67. The NBLKACGR attribute must be set at a value > 0 when one UTRAN neighbour
cell has been configured.
68. The CELLGLID cannot be equal to the CELLGLID assigned to another BTS or
TGTBTS.
69. In order to avoid wrong parameter settings, it is required that:
fRActivationThreshold1 < hRActivationThreshold1
fRActivationThreshold2 < hRActivationThreshold2
fRActivationAMRThreshold1 < hRActivationThreshold1
fRActivationAMRThreshold2 < hRActivationthreshold2
The number of intracell handovers between AMRFR and AMRHR is decreased as
the configured hysteresis between hRActivationThresholdi and hRDecomprThresh-
oldi is increased.
Example of Command Execution:
Set BTS:NAME=BTSM:0/BTS:0,CELLGLID="123"-"456"-1-1,BSIC=1-2,
PLMNP=5,CELLRESH=5,MSTXPMAXGSM=5,MSTXPMAXDCS=<NULL>,
MSTXPMAXPCS=<NULL>,RXLEVAMI=5,RDLNKTO=5,RACHBT=5,
RACHLAS=102,TCCCHLDI=1,PCCCHLDI=255,FACCHQ=5,CELLTYP=STDCELL,
BCCHFREQ=2,CALLF01=123,CRESPARI=1,CRESOFF=2, TEMPOFF=1,
PENTIME=2,CBQ=1,NMULBAC=1,CONCELL=FALSE,BTSHSCSD=FALSE,
EHRACT=TRUE,HRACTT1=10,HRACTT2=12,
SDCCHCONGTH=70,EEOTD=TRUE,AMRFRC1=RATE_01,AMRFRTH12=7-2,
AMRFRC2=RATE_03,AMRFRTH23=12-2,AMRFRC3=RATE_06,
AMRFRTH34=23-2,AMRFRC4=RATE_08,AMRHRC1=RATE_01,
AMRHRTH12=19-0,AMRHRC2=RATE_02,AMRHRTH23=24-0,AMRHRC3=RATE_03,
AMRHRTH34=26-0,AMRHRC4=RATE_04,AMRFRIC=START_MODE_FR,
AMRHRIC=START_MODE_HR,AMRLKAT=100,QSRHI=OMDB78,FDDQMI=MDB17,
FDDQO=DB12,QSRHCINI=ALWAYS,FDDREPQTY=RSCP,FDDMURREP=2,
UMTSSRHPRI=TRUE,EANTHOP=FALSE,ANTHOPMOD=NOBCCHTRX,
ANTHOPP=SECOND,GUARMABIS=0,QSRHC=UMDB78,TDDQO=8, TDDMUR-
REP=2, REPTYP=NORMAL,ETXDIVTS=FALSE,TXDIVTSEXCPT=NONE,


320 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
TXDVTSPAR=MDB1,TAADJ=1,LCBM0=NULL,LCBM1=NULL,LCBM2=NULL,
LCBM3=NULL,HRACTAMRT1=6000,HRACTAMRT2=6000, EPAT1=6000,
EPAT2=6000, MAXRETR=One,NSLOTST=0,NY1=1,NBLKACGR=2,NFRAMEPG=2,
MSTXPMAXCH=0,PWROFS=0,ASCISER=ASCI_ENABLED,NOCHFBLK=1,
NOCHBLKN=1,ASCIULR=ULRDISABLE,INTCLASS=TRUE,
INTAVEPR=2-13-26-50-56,RFRSINDP=1,CELLBARR=FALSE,
CREALL=NOTALLOWED,NALLWACC=na0,EC=FALSE,SMSCBUSE=TRUE,
DTXDLFR=TRUE,DTXDLHR=TRUE,DTXUL=MAYFSHNH,IMSIATDT=FALSE,
HOPP=TRUE,T3212=0,PWROUT=m8db -m6db -db3,DIRTCHASS=FALSE,
BMONTH=Enabled(30)-Enabled(60)-Enabled(90),
BSMONTH=Disabled(0)Disabled(0)Disabled(0),EARCLM=TRUE,
HOPMODE=BBHOP,EXCDIST=1,EEXCDIST=FALSE,EQ=DISABLED,
EPRE=ENABLED,T200=44-31-41-90-90-90-135,T3101=HLFSEC-12,
T3105=MS10-4,T3109=HLFSEC-30,T3111=HLFSEC-3,TSYNC=200,TSYNCUL=10,
TSYNCDL=10,TSYNCR=200, TTRAU=200,ENANCD=DISABLED,NCDP1=H8-6,
NCDP2=H21-30,TGRANT=100, NRPGRANT=10,VGRULF=8,TNOCH=3,
TUPLREP=5, PNOFACCH=2.5, ENPERNOTDE=FALSE, ENDMA=FALSE,
CCALL=CCALLF01&CCALLF02&CCALLF03, FHAMRFRC1=RATE_01,
FHAMRFRC2=RATE_03, FHAMRFRC3=RATE_06, FHAMRFRC4=RATE_08,
FHAMRFRTH12=7-2, FHAMRFRTH23=12-2, FHAMRFRTH34=23-2,
FHAMRHRC1=RATE_01, FHAMRHRC2=RATE_02,
FHAMRHRC3=RATE_03,FHAMRHRC4=RATE_04, FHAMRHRTH12=12-0,
FHAMRHRTH23=24-0, FHAMRHRTH34=26-0, FHAMRFRIC=START_MODE_FR,
FHAMRHRIC=START_MODE_HR, EAC=FALSE, ACFERMAX=5.0, ACBQPMAX=5.0,
ACPER=SACCH_120, ACLNKTP=UL_AND_DL_SAMPLES_COMMONLY,
ACBQPFF=0.2, ACEFLFF=0.04, ACMINEFLDMA=PER_10, ACMAX-
ELDMA=PER_50,MEAEXTBCCH=TRUE,SLLPRM=LY_00, CRTSWSPELL-
PRM=LY_00&LY_02&LY_08, AMRFRLLPRM=LY_01, AMRHRLLPRM=LY_03,
CRTSWDLLPRM=LY_02&LY_00, GLLPRM=LY_05&LY_02, ELLPRM=<NULL>,
ASCILLPRM=<NULL>, HSCSDLLPRM=<NULL>,
CRTSWSPELLCOM=LY_00&LY_02&LY_08, AMRFRLLCOM=LY_01, AMRHR-
LLCOM=LY_03, CRTSWDLLCOM=LY_02&LY_00, GLLCOM=LY_05&LY_02,
ELLCOM=<NULL>, HSCSDLLCOM=<NULL>, FRACTTH1=3000, FRACTTH2=3000,
FRACTAMRTH1=3000, FRACTAMRTH2=3000, EHRACTAMR=TRUE, FRA-
NOFFS=NULL, BURNOFFS=NULL,QLWPS=3, QLPUB=3, LWWPSPRI=2,
WPSPREF=2-1, CSCE=URBAN,FDDREPTH=RXLEV_00, FDDREPO=DB00,
TDDREPRH=RXLEV_00, FDDREPO=DB00, FDDREPTH2=0,
FDDRSCPMI=MDB101, CUCONF=homogeneous, EFCRESEL=FALSE, FDDQ-
MIO=DB00;
SHUTDOWN BTS
SHUTDOWN BTS NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

321
CML:BSC BTS
Id:0900d805800d4446
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SHUTDOWN BTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The BSS is able to force a mobile station to perform an intercell or inter-BSC HO by
means of the O&M SHUTDOWN command. After the SHUTDOWN command is
entered, the system tries to perform an intercell or inter-BSC HO per mobile station; in
case of failure, a further attempt is performed every 30 seconds for the next 5 minutes
period.
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


322 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4446
BTS
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ---------->
LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown BTS:NAME=BTSM:0/BTS:0;
UNLOCK BTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS UNLOCK BTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)
UNLOCK BTS NAME=BTSM:0..199/BTS:0..23;


A30808-X3247-M230-6-7619

323
CML:BSC BTS
Id:0900d805800d4446
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock BTS:NAME=BTSM:0/BTS:0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


324 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
BTSM
The BTSM object provides services to control the functionalities of one or more BTSs
located at the same site. It performs all the operation and maintenance functions
common to all transceivers.
CREATE BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CREATE BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The object BTSM represents the O&M functionality related to a site and not to a specific
BTS. A BTSM object is a logical grouping of one or more BTSs with common
management needs. A consequence of this command is that also a BTSE object with
the identical instance number will come into existence and can be queried e.g. for its
attributes.
Long Names:
NAME Addres of the managed object
EXPSWV expectedSwVersion
SHLAPDIT shortLapdIntTimer
OMLAPDRT omLapdRelTimer
EMT1 emergencyTimer1
EMT2 emergencyTimer2
SALUNAME salesUniqueName
PCMCON<n> pcmConnection<n>
FLAPDOVLTH firstLapdOverloadThreshold
SLAPDOVLTH secondLapdOverloadThreshold
LAPDOVLT lapdOverloadTimer
TEI tei
LPDLMSAT lapdmLinkSatellited
ABISHRACTTHR abisHalfRateActivationThreshold
CREATE BTSM NAME=BTSM:0..199 ,EXPSWV= [,SHLAPDIT=] [,OMLAP-
DRT=] [,EMT1=] [,EMT2=] [,SALUNAME=] [,PCMCON<n>=]
[,FLAPDOVLTH=] [,SLAPDOVLTH=] [,LAPDOVLT=] ,TEI=
[,LPDLMSAT=] [,ABISHRACTTHR=] [,ABISTRFHITHR=]
[,ABISTRFLTHR=] [,GASTRABISTH=] [,EINTSITSYN=]
[,ABISMONTH=] [,ABISFRACTTHR=];


A30808-X3247-M230-6-7619

325
CML:BSC BTSM
Id:0900d805800d4206
ABISTRFHITHR abisTrafficHighThreshold
ABISTRFLTHR abisTrafficLowThreshold
GASTRABISTH gprsAllocationStrategyAbisThresholds
EINTSITSYN enableInterSiteSync
ABISMONTH abisMonitorThreshold
ABISFRACTTHR abisFullRateActivationThreshold
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Successful
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The field pcmbNumber of the attributes PCMCONx (x = 1..7) must
specify the PCMB carrying the LPDLM associated to the BTSM
(there must be at least one LPDLM per each BTSM connected).
The PCMB lines specified in all the given PCMCONx (x = 1..7)
attributes must be already equipped.
INVALID_SVR
The EXPSWV assigned to the BTSM is not handled by the software
version of BSC. The EXPSWV is present on the BSC disk and the
BTSE corresponding to the BTSM instance is aligned to it by the
BSC.
The EXSPWV is not compatible with the HDCTR feature.
UNSUCCESSFUL_WRONG_PCMB_NUMBER
Different PCMCONx must refer to different PCMB instances.
UNSUCCESSFUL_WRONG_PORT_NUMBER
Make reference to Application Guidelines n. 3, n. 4, n. 5.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The values related to the First LAPD Overload Threshold
(FLAPDOVTH) and the Second LAPD Overload Threshold
(SLAPDOVTH) parameters must be set according to the following
rule: FLAPDOVTH < SLAPDOVTH.


326 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
Between the AbisTrafficHighThreshold and the
AbisTrafficLowThreshold the following relationship must be veri-
fied: ABISTRFHITHR - ABISTRFLTHR >= 20.
ABISFRACTTHR must be lower than ABISHRACTTHR.
INVALID_SALES_UNIQUE_NAME
If the SALUNAME is defined, it must be different from SALUNAME
of the other BTSMs equipped.
INCOMP_NESWLOAD_VS_MESSAGE
PCMCON2 and/or PCMCON3 cannot be set at a value different
from NULL if the SW Version running on the BTSM belongs to
BR6.0 release (see EXPSWV parameter description).
The ABISHRACTTHR, ABISTRFHITHR and ABISTRFLTHR
attributes must have NULL value if the SW Version running on the
BTSM belongs to BR6.0 release (see EXPSWV parameter
description), and a value different by <NULL> with SW Version >=
BR7.0.
The GASTRABISTH attribute must be set at NULL value if the SW
Version running on the BTSM belongs to BR6.0 release, while it
must be set at a value different from NULL if the SW Version
running on the BTSM belongs to BR7.0 release (see EXPSWV
parameter description) .
No more than two (BR6.0) or four (BR7.0) different port number can
be specified in PCMCONxx attributes of one BTSM, if the Sw
version is < 8.0.
In order to set EXPSWV to a value belonging to BR7.0 release, the
USG attribute must be different from INACTIVE in all the subordi-
nate ADJC objects.
In order to set EXPSWV to a value belonging to BR7.0 release, the
MEAEXTBCCH attribute must be set to FALSE in all the subordi-
nate BTS objects.
With HW version different by BTSplus or BS 240 XS the attribute
EINTSITSYN cannot be set to TRUE.
With SW version less than BR8.0 the attribute EINTSITSYN must
be NULL, and viceversa for SW greater or equal than BR8.0 the
attribute must be assume a value different by NULL.
With SW version less than BR8.0 the attribute ABISFRACTTHR
must be NULL, and viceversa for SW greater or equal than BR8.0
the attribute must be assume a value different by NULL.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The thresholdIdleAbisSU field of the GASTRABISTH attribute has
to be lower or equal than the thresholdIdleAbisRU field and the
thresholdIdleAbisHV field has to be lower or equal than the
thresholdIdleAbisVH field.


A30808-X3247-M230-6-7619

327
CML:BSC BTSM
Id:0900d805800d4206
Application Guidelines:
1. After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
2. An offset of 30 seconds is added to timer SHLAPDIT to manage the links
interruptions.
3. At least one PCMCONx must be connected to PORT_0.
4. The two fields of PCMCONx (x = 1..7) must be both specified or both skipped.
5. Port numbers specified in all the given PCMCONx (x = 1..7) attributes must be com-
patible with the BTS hardware version, as shown in the table below:
The values PORT_2, PORT_4 or PORT_6 can be selected only if the object COSA
is installed; with object COBA installed only the value PORT_0 can be selected.
6. The hardware object PORT_<n> corresponds to the object BPORT:<n>. At the
BTSE side, the BPORT object must be previously created by means of the CREATE
BPORT command.
Example of Command Execution:
Create BTSM:NAME=BTSM:0,EXPSWV="01-00-01-01-04-04_95-03-01",
SHLAPDIT=3,OMLAPDRT=4,EMT1=20,EMT2=30,SALUNAME="AD042S7449F",
PCMCON0=PCMB_0-PORT_0,PCMCON1=PCMB_1-PORT_0,
PCMCON2=PCMB_2-PORT_0,PCMCON3=PCMB_3-PORT_0,
PCMCON4=PCMB_4-PORT_0, PCMCON5=PCMB_5-PORT_0,
PCMCON6=PCMB_6-PORT_0, PCMCON7=PCMB_7-PORT_0,
FLAPDOVLTH=10-5,SLAPDOVLTH=15-7,LAPDOVLT=<NULL>,TEI=5,
LPDLMSAT=TRUE,ABISHRACTTHR=60,ABISTRFHITHR=90,ABISTRFLTHR=80,
GASTRABISTH=10-20-15-25, EINTSITSYN=TRUE, ABISMONTH=30-60-90, ABIS-
FRACTTHR=40;
DELETE BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM DELETE BTSM
BTSE type PortNumber
BS-21E, BS-22, BS-20, BS-
60, BS61E
PORT_0, PORT_2
BS-240, BS-241, BS-240XL,
BS-4x, BS-40 II, BS-82 II
PORT_0, PORT_1, PORT_2, PORT_3,
PORT_4, PORT_5, PORT_6, PORT_7
BS-82 PORT_0
BS-240 XS PORT_0, PORT_2
DELETE BTSM NAME=BTSM:0..199;


328 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created BTSM. A consequence of this command is
that also the corresponding BTSE object with the same instance number will no longer
exist.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete BTSM:NAME=BTSM:0;
GET BTSM
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a BTSM, the relative object instance must be
in LOCKED state.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
All the BTS object instances associated to the BTSM object
instance must be previously deleted.
The CBTS associated must be previously deleted.
GET BTSM NAME=BTSM:0..199 [,REQATTL= EXPSWV ,SHLAPDIT
,OMLAPDRT ,EMT1 ,EMT2 ,SALUNAME ,PCMCON<n>
,FLAPDOVLTH ,SLAPDOVLTH ,LAPDOVLT ,TEI ,LPDLM-
SAT ,BTSEFAM ,TOPOREL ,ABISHRACTTHR ,ABISTRF-
HITHR ,ABISTRFLTHR ,GASTRABISTH ,EINTSITSYN
,ABISMONTH ,ABISFRACTTHR];


A30808-X3247-M230-6-7619

329
CML:BSC BTSM
Id:0900d805800d4206
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GET BTSM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the specified BTSM instance.
Long Names:
NAME Addres of the managed object
EXPSWV expectedSwVersion
SHLAPDIT shortLapdIntTimer
OMLAPDRT omLapdRelTimer
EMT1 emergencyTimer1
EMT2 emergencyTimer2
SALUNAME salesUniqueName
PCMCON<n> pcmConnection<n>
FLAPDOVLTH firstLapdOverloadThreshold
SLAPDOVLTH secondLapdOverloadThreshold
LAPDOVLT lapdOverloadTimer
TEI tei
LPDLMSAT lapdmLinkSatellited
BTSEFAM btseFamily
TOPOREL topologicalRelationship
ABISHRACTTHR abisHalfRateActivationThreshold
ABISTRFHITHR abisTrafficHighThreshold
ABISTRFLTHR abisTrafficLowThreshold
GASTRABISTH gprsAllocationStrategyAbisThresholds
EINTSITSYN enableInterSiteSync
ABISMONTH abisMonitorThreshold
ABISFRACTTHR abisFullRateActivationThreshold
System Responses:
- Operation Completed
NAME: name
EXPSWV: expectedSwVersion
SHLAPDIT: shortLapdIntTimer
OMLAPDRT omLapdRelTimer
EMT1: emergencyTimer1


330 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
EMT2: mergencyTimer2
SALUNAME: salesUniqueName
PCMCON0: pcmConnection0
PcmbNumber
PortNumber
PCMCON1: pcmConnection1
PcmbNumber
PortNumber
PCMCON2: pcmConnection2
PcmbNumber
PortNumber
PCMCON3: pcmConnection3
PcmbNumber
PortNumber
PCMCON4: pcmConnection4
PcmbNumber
PortNumber
PCMCON5: pcmConnection5
PcmbNumber
PortNumber
PCMCON6: pcmConnection6
PcmbNumber
PortNumber
PCMCON7: pcmConnection7
PcmbNumber
PortNumber
FLAPDOVTH: firstLapdOverloadThreshold
upperThreshold
lowerThreshold
SLAPDOVTH: secondLapdOverloadThreshold
upperThreshold
lowerThreshold
LAPDOVLT: lapdOverloadTimer
TEI: tei
LPDLMSAT: lapdmLinkSatellited
BTSEFAM: btseFamily


A30808-X3247-M230-6-7619

331
CML:BSC BTSM
Id:0900d805800d4206
GET BTSM BASICS
TOPOREL: topologicalRelationship
ABISHRACTTHR:abisHalfRateActivationThreshold
ABISTRFHITHR:abisTrafficHighThreshold
ABISTR-
FLTHR:
abisTrafficLowThreshold
GASTRA-
BISTH:
gprsAllocationStrategyAbisThresholds
thresholdIdleAbisHV
thresholdIdleAbisVH
thresholdIdleAbisSU
thresholdIdleAbisRU
EINTSITSYN: enableInterSiteSync
ABISMONTH: abisMonitorThreshold
ABISFRACTTHR: abisFullRateActivationThreshold
NAME: name
EXPSWV: expectedSwVersion
SHLAPDIT: shortLapdIntTimer
OMLAPDRT omLapdRelTimer
EMT1: emergencyTimer1
EMT2: mergencyTimer2
SALUNAME: salesUniqueName
PCMCON0: pcmConnection0
PcmbNumber
PortNumber
PCMCON1: pcmConnection1
PcmbNumber
PortNumber
PCMCON2: pcmConnection2
PcmbNumber
PortNumber
PCMCON3: pcmConnection3
PcmbNumber
PortNumber
PCMCON4: pcmConnection4


332 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
- Operation Failed
PcmbNumber
PortNumber
PCMCON5: pcmConnection5
PcmbNumber
PortNumber
PCMCON6: pcmConnection6
PcmbNumber
PortNumber
PCMCON7: pcmConnection7
PcmbNumber
PortNumber
FLAPDOVTH: firstLapdOverloadThreshold
upperThreshold
lowerThreshold
SLAPDOVTH: secondLapdOverloadThreshold
upperThreshold
lowerThreshold
LAPDOVLT: lapdOverloadTimer
TEI: tei
LPDLMSAT: lapdmLinkSatellited
BTSEFAM: btseFamily
TOPOREL: topologicalRelationship
ABISHRACTTHR:abisHalfRateActivationThreshold
ABISTRFHITHR:abisTrafficHighThreshold
ABISTR-
FLTHR:
abisTrafficLowThreshold
GASTRA-
BISTH:
gprsAllocationStrategyAbisThresholds
thresholdIdleAbisHV
thresholdIdleAbisVH
thresholdIdleAbisSU
thresholdIdleAbisRU
EINTSITSYN: enableInterSiteSync
ABISMONTH:abisMonitorThreshold
ABISFRACTTHR: abisFullRateActivationThreshold


A30808-X3247-M230-6-7619

333
CML:BSC BTSM
Id:0900d805800d4206
NACK CAUSES:
Application Guidelines:
None.
GET BTSM BASICS
None.
Example of Command Execution:
Get BTSM:NAME=BTSM:0,REQATTL=EXPSWV&SHLAPDIT&OMLAPDRT&EMT1&
EMT2&SALU-
NAME&PCMCON0&PCMCON1&PCMCON2&PCMCON3&PCMCON4&PCMCON5&P
CMCON6&PCMCON7&FLAPDOVLTH&SLAPDOVLTH&LAPDOVLT&TEI&LPDLM-
SAT&BTSEFAM&
TOPOREL&ABISHRACTTHR&ABISTRFHITHR&ABISTRFLTHR&GASTRA-
BISTH&EINTSITSYN&ABISMONTH&ABISFRACTTHR;
GET BTSM BASICS
Get BTSM BASICS:NAME=BTSM:0;
GET BTSM BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GET BTSM BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the specified BTSM instance.
Long Names:
NAME Addres of the managed object
EXPSWV expectedSwVersion
SHLAPDIT shortLapdIntTimer
OMLAPDRT omLapdRelTimer
EMT1 emergencyTimer1
EMT2 emergencyTimer2
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET BTSM BASICS NAME=BTSM:0..199;


334 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
SALUNAME salesUniqueName
PCMCON<n> pcmConnection<n>
FLAPDOVLTH firstLapdOverloadThreshold
SLAPDOVLTH secondLapdOverloadThreshold
LAPDOVLT lapdOverloadTimer
TEI tei
LPDLMSAT lapdmLinkSatellited
BTSEFAM btseFamily
TOPOREL topologicalRelationship
ABISHRACTTHR abisHalfRateActivationThreshold
ABISTRFHITHR abisTrafficHighThreshold
ABISTRFLTHR abisTrafficLowThreshold
GASTRABISTH gprsAllocationStrategyAbisThresholds
EINTSITSYN enableInterSiteSync
ABISMONTH abisMonitorThreshold
ABISFRACTTHR abisFullRateActivationThreshold
System Responses:
See GET BTSM
Application Guidelines:
See GET BTSM
Example of Command Execution:
See GET BTSM
GET BTSM STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GET BTSM STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
BTSM object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
GET BTSM STAT NAME=BTSM:0..199;


A30808-X3247-M230-6-7619

335
CML:BSC BTSM
Id:0900d805800d4206
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get BTSM STAT:NAME=BTSM:0;
GETINFO BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GETINFO BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The report complete indication.
2. The BTSE rack type.
3. The "OSU running" object and the "OSU version".
4. The Sales Unique Name of the BTSM.
5. Abis type (Static or Dynamic).
6. The BTSM state and statuses: AST, OST, AVS, PRS.
7. For each PCMB line supporting the BTSE:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO BTSM NAME=BTSM:0..199;


336 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
the number of pcm line;
the AST, OST, AVS states and statuses;
the BTSE port to which the pcm line is connected.
8. Subpools maps, per PCMB and LPDLM (order: subTsl0, subTsl1, subTsl2,
subTsl3).
9. Total number of radio timeslots (CHANs) configured in the BTSM.
10. Total number of SUBTSLBs configured on the BTSM.
11. Number of full busy in service SUBTSLBs (both the subchannels used).
12. Number of half busy in service SUBTSLBs (only a subchannel used).
13. Number of out of service SUBTSLBs.
14. Number of in service fully idle SUBTSLBs.
15. The LMU Link Status.
16. For each BTS and TRX: the administrative (AST) and operational (OST) states, the
availability (AVS) and procedural (PRS) statuses.
17. For all the hardware managed objects:
the administrative (AST) and operational (OST) states, the alarm (ALR), the
availability (AVS), procedural (PRS) and the standby (STB) statuses.
The carrier capability (UNKNOWN, GSM, EDGE, FOUR_RX_DIV).
( I ) If the LMT is connected in remote mode, it is not possible to execute this command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO BTSM ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT:
NAME = BTSM:1
REPORT COMPLETE: TRUE
BTSE RACK TYPE: BS240XL
OSU: BTSMOSUSW 0
ESU RUNNING VERSION: 01-04-08-01-07-00_98-07-21
SALES UNIQUE NAME: VOGHERA
ABIS TYPE: DYNAMIC
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PROCEDURAL STATUS: NONE


A30808-X3247-M230-6-7619

337
CML:BSC BTSM
Id:0900d805800d4206
PCM LINES SUPPORTING BTSE:
PCMB 12
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
BTSE PORT: PORT_2
PCMB 13
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
BTSE PORT: PORT_4
ABIS POOL:
LPDLM: 0
PCMB: 12
TIMESLOT: 5
POOL MAP
TS01:1111 TS02:0111 TS03:0011 TS04:0000 TS05:0000 TS06:1111
TS07:0011 TS08:1010 TS09:0011 TS10:0000 TS11:0011 TS12:0000
TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000
TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000
TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:0000 TS30:1001
TS31:0011
LPDLM: 1
PCMB: 12
TIMESLOT: 13-0
POOL MAP
TS01:0000 TS02:1000 TS03:1100 TS04:0000 TS05:0000 TS06:0000
TS07:1100 TS08:0000 TS09:0000 TS10:0000 TS11:0000 TS12:0000
TS13:0000 TS14:0000 TS15:0000 TS16:0000 TS17:0000 TS18:0000
TS19:0000 TS20:0000 TS21:0000 TS22:0000 TS23:0000 TS24:0000
TS25:0000 TS26:0000 TS27:0000 TS28:0000 TS29:1111 TS30:0000
TS31:1100
TOTAL NUMBER OF CONFIGURED CHANS: 100
TOTAL NUMBER OF CONFIGURED SUBTSLBS: 180
FULLY BUSY SUBTSLBS: 80


338 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
HALF BUSY SUBTSLBS: 10
OUT OF SERVICE SUBTSLBS: 30
FULLY IDLE SUBTSLBS: 60
LMU LINK ACTIVE: TRUE
OBJECT ADMINISTRATIVE OPERATIONAL AVAILABILITY
BTS 2 UNLOCKED ENABLED DEPENDENCY REMOTE_DEPENDENCY
TRX 0 UNLOCKED ENABLED NONE
TRX 23 UNLOCKED ENABLED NONE
TRX 1 UNLOCKED ENABLED NONE
TRX 2 LOCKED ENABLED NONE
BTS 3 UNLOCKED ENABLED NONE
TRX 0 UNLOCKED ENABLED NONE
TRX 8 UNLOCKED ENABLED NONE
TRX 1 UNLOCKED ENABLED NONE
OBJECT PROCEDURAL
BTS 2 NONE
TRX 0 NONE
TRX 23 NONE
TRX 1 NONE
TRX 2 NONE
BTS 3 NONE
TRX 0 NONE
TRX 8 NONE
TRX 1 NONE
OBJECT ADMINISTRATIVE OPERATIONAL ALARM AVAILABILITY
ACDCP 0-1 UNLOCKED ENABLED CLEARED NONE
ACT 0-1 UNLOCKED ENABLED CLEARED NONE
BATTERY 0-1 UNLOCKED ENABLED CLEARED NONE
COBA 0-0 UNLOCKED ENABLED CLEARED NONE
COSA 0-1 UNLOCKED ENABLED CLEARED NONE
CU 0-2 UNLOCKED ENABLED CLEARED NONE
FANP1-0 UNLOCKED ENABLED CLEARED NONE
FTNFP 0-1 UNLOCKED ENABLED CLEARED NONE
FVSWRP 0-0 UNLOCKED ENABLED CLEARED NONE
DILNA 1-0 UNLOCKED ENABLED CLEARED NONE


A30808-X3247-M230-6-7619

339
CML:BSC BTSM
Id:0900d805800d4206
DIDCTMA 1-1 UNLOCKED ENABLED CLEARED NONE
DUVSWR 0-1 UNLOCKED ENABLED CLEARED NONE
DULNA 1-1 UNLOCKED ENABLED CLEARED NONE
DUCTMA 0-0 UNLOCKED ENABLED CLEARED NONE
TMA 0-0 UNLOCKED ENABLED CLEARED NONE
BPORT 3 UNLOCKED ENABLED CLEARED NONE
XCONNECT-0 UNLOCKED ENABLED CLEARED NONE
ENVABTSE 0-2 UNLOCKED ENABLED CLEARED NONE
LMU 0 UNLOCKED ENABLED CLEARED NONE
SDUSEC 0-1 UNLOCKED ENABLED CLEARED NONE
SDUSUBSEC 0-1 UNLOCKED ENABLED CLEARED NONE
SDUTXSW 0-1 UNLOCKED ENABLED CLEARED NONE
SDULNA UNLOCKED ENABLED CLEARED NONE
SYNCBTSE UNLOCKED ENABLED CLEARED NONE
FCUMAIN 1-11 UNLOCKED ENABLED CLEARED NONE
FCUTR 1-0 UNLOCKED ENABLED CLEARED NONE
OBJECT PROCEDURAL STANDBY CAPABILITY
ACDCP 0-1 NONE PROVIDING_SERVICE
ACT 0-1 NONE NONE
BATTERY 0-1 NONE NONE
COBA 0-0 NONE NONE
COSA 0-1 NONE NONE
CU 0-2 NONE NONE GSM
FANP 1-0 NONE NONE
FTNFP 0-1 NONE NONE
FVSWRP 0-0 NONE NONE
DILNA 1-0 NONE NONE
DIDCTMA 1-1 NONE NONE
DUVSWR 0-1 NONE NONE
DULNA 1-1 NONE NONE
DUCTMA 0-0 NONE NONE
TMA 0-0 NONE NONE
BPORT 3 NONE NONE
XCONNECT 0 NONE NONE
ENVABTSE 0-2 NONE NONE
LMU 0 NONE NONE
SDUSEC 0-1 NONE NONE


340 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
SDUSUBSEC 0-1 NONE NONE
SDUTXSW 0-1 NONE NONE
SDULNA NONE NONE
SYNCBTSE NONE NONE
FCUMAIN 1-11 NONE NONE
FCUTR 1-0 NONE NONE FOUR_RX_DIV
END OF REPORT
Note on Poolmap:
For each LPDLM a list of the SUBTSLBs assigned is reported. The map field is a 16
BYTEs where in the first BYTE the initial 4 bits are the sub-timeslots of the TSLB-0 (that
is not displayed because it is the synchronous timeslot of PCM line).
example:
the SUBTSLBs assigned to the LPDLM are SUBTSLB 1-0, SUBTSLB 1-2 and
SUBTSLB 1-3 and are showed as:
POOL MAP
TS01:1101 TS02:.......
Timeslot displayed can be either 24 or 31, depending on current configuration.
- Operation Failed
GETINFO BTSM NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:24:45 2209/1998
*** RESPONSE TO JOB 1***
Get Info Report Nack BTSM:
name = BTSM:1
nackCause = <nack cause>
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
subslot3 subslot2 subslot1 subslot0 Time slot 0 (sync)
Time slot 1 Time slot 0 (sync)
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
1 1 0 1 0 0 0 0
Time slot 1 Time slot 0 (sync)


A30808-X3247-M230-6-7619

341
CML:BSC BTSM
Id:0900d805800d4206
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo BTSM:NAME=BTSM:0;
GETRELATIONSHIP BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GETRELATIONSHIP BTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the BTSM object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW, PPXL and BTSE instance (it is equal to the BTSM).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the system.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another GetInfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 GetInfo commands already in progress.
GETRELATIONSHIP
BTSM
NAME=BTSM:0..199;


342 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship BTSM:NAME=BTSM:0;
GETSUBO BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM GETSUBO BTSM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the
subordinate list.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object does not provide any relationship attribute.
GETSUBO BTSM NAME=BTSM:0..199;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

343
CML:BSC BTSM
Id:0900d805800d4206
Application Guidelines:
None.
Example of Command Execution:
Getsubo BTSM:NAME=BTSM:0;
LOCK BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LOCK BTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
3. Before entering this command it is necessary to lock the Abis.
Example of Command Execution:
Lock BTSM:NAME=BTSM:0;
LOCK BTSM NAME=BTSM:0..199;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


344 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
SET BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM SET BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the BTSM parameters.
Long Names:
NAME Addres of the managed object
EXPSWV expectedSwVersion
SHLAPDIT shortLapdIntTimer
OMLAPDRT omLapdRelTimer
EMT1 emergencyTimer1
EMT2 emergencyTimer2
SALUNAME salesUniqueName
PCMCON<n> pcmConnection<n>
FLAPDOVLTH firstLapdOverloadThreshold
SLAPDOVLTH secondLapdOverloadThreshold
LAPDOVLT lapdOverloadTimer
ABISHRACTTHR abisHalfRateActivationThreshold
ABISTRFHITHR abisTrafficHighThreshold
ABISTRFLTHR abisTrafficLowThreshold
GASTRABISTH gprsAllocationStrategyAbisThresholds
EINTSITSYN enableInterSiteSync
ABISMONTH abisMonitorThreshold
ABISFRACTTHR abisFullRateActivationThreshold
System Responses:
- Operation Completed
Successful
- Operation Failed
SET BTSM NAME=BTSM:0..199 [,EXPSWV=] [,SHLAPDIT=] [,OMLAP-
DRT=] [,EMT1=] [,EMT2=] [,SALUNAME=] [,PCMCON<n>=]
[,FLAPDOVLTH=] [,SLAPDOVLTH=] [,LAPDOVLT=]
[,ABISHRACTTHR=] [,ABISTRFHITHR=] [,ABISTR-
FLTHR=] [,GASTRABISTH=] [,EINTSITSYN=] [,ABIS-
MONTH=] [,ABISFRACTTHR=];


A30808-X3247-M230-6-7619

345
CML:BSC BTSM
Id:0900d805800d4206
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
INVALID_SVR
Make reference to Application Guidelines n. 1, n. 3, n. 4, n.5, n.
6, n. 9, n. 10, n. 11, n. 12, n. 13, n. 14.
The EXSPWV is not compatible with the HDCTR feature.
Only BTS_plus and BS240XS with sw_ver equal or major of
BR8.0 support DMA.
UNSUCCESSFUL_WRONG_PCMB_NUMBER
Different PCMCONx must refer to different PCMB instances.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The values related to the First LAPD Overload Treshold
(FLAPDOVTH) and the Second LAPD Overload Threshold
(SLAPDOVTH) parameters must be set according to the follow-
ing rule: FLAPDOVTH < SLAPDOVTH.
Between the AbisTrafficHighThreshold and the
AbisTrafficLowThreshold the following relationship must be
verified: ABISTRFHITHR - ABISTRFLTHR >= 20.
ABISFRACTTHR must be lower than ABISHRACTTHR.
INVALID_SALES_UNIQUE_NAME
If the SALUNAME is defined, it must be different from
SALUNAME of the other BTSMs equipped.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The field pcmbNumber of the attributes PCMCONx (x = 1..7)
must specify the PCMB carrying the LPDLM associated to the
BTSM (there must be at least one LPDLM per each BTSM con-
nected).
The PCMB lines specified in all the given PCMCONx (x = 1..7)
attributes must be already equipped.
UNSUCCESSFUL_WRONG_PORT_NUMBER
Make reference to Application Guidelines n. 4, n. 8, n. 9.
INCOMP_NESWLOAD_VS_MESSAGE
If BTSM SW version changes from a value belonging to BR7.0
release to a value belonging to BR6.0 release (see EXPSWV
parameter description) the EBSPWRC and EMSPWRC
attributes (see PWRC object) can not assume ADAPTIVE
value.


346 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
The ABISHRACTTHR, ABISTRFHITHR and ABISTRFLTHR
attributes must have NULL value if the SW Version running on
the BTSM belongs to BR6.0 release (see EXPSWV parameter
description), and a value different by <NULL> with SW Ver-
sion>= BR7.0
The EXPSWV attribute cannot be set at a value belonging to
BR6.0 release (see the parameter description) if at least one
subordinated PTPPKF object has the CSCH3CSCH4SUP
attribute set at TRUE.
In order to set EXPSWV at a value belonging to BR6.0 release
(see the parameter description) the REPTYP attribute must be
set at NORMAL in all the subordinated BTS objects.
The REPTYP attribute can be set at ENHANCED value only if
the SW Version running on the superordinate BTSM belongs to
BR7.0 release (see EXPSWV parameter description).
The EXPSWV value can not be set at a value belonging to
BR6.0 release (see the parameter description) if at least one of
AMRHRCi attribute values is RATE_05.
In order to set EXPSWV at a value belonging to BR6.0 release
(see the parameter description) the ELKADPT attribute must be
set at FALSE in all the subordinated BTS objects.
The EUSDCHO attribute (see BSC object) must be set at
FALSE if the SW Version running on the BTSM belongs to
BR6.0 release (see EXPSWV parameter description).
The EUHO, EUBCHO, EUIMPHO, EUSCHO attributes (see
HAND object) must be set at FALSE if the SW Version running
on the BTSM belongs to BR6.0 release (see EXPSWV
parameter description).
The GASTRABISTH attribute must be set at NULL value if the
SW Version running on the BTSM belongs to BR6.0 release,
while it must be set at a value different from NULL if the SW
Version running on the BTSM belongs to BR7.0 release (see
EXPSWV parameter description) .
To set the EXPSWV parameter so that the type of Abis
changes from dynamic to static, at least on SUBTSLB per
CHAN must be available on PCMB connecting the BTSM.


A30808-X3247-M230-6-7619

347
CML:BSC BTSM
Id:0900d805800d4206
With the BSC running BR 7.0 software, and a downgrade on
the BTSM software has to be performed after the BTSM has
already been upgraded from BR6.02 to BR7.0, it is only
possible as long as the database for the BTSM has not been
modified. If the database has been modified on the BTSM, i.e.
a new BTS is created, etc. while the BTSM is running BR7.0
code, then it is not possible to do the downgrade due to
enhanced features being incorporated into the new BTSM,
which is not compatible with the old software (BR6.02). To do
the downgrade, one has to delete the BTS or reset the param-
eters in the BTSM to the original values. In other words, the
database must be brought back to the original status before the
upgrade occurred.
With HW version different by BTSplus or BS 240 XS the
attribute EINTSITSYN cannot be set to TRUE.
With SW version less than BR8.0 the attribute EINTSITSYN
must be NULL, and viceversa for SW greater or equal than
BR8.0 the attribute must be assume a value different by NULL.
With SW version less than BR8.0 the attribute ABISFRACT-
THR must be NULL, and viceversa for SW greater or equal
than BR8.0 the attribute must be assume a value different by
NULL.
With SW version less than BR8.0 no more than one (BR 6.0) or
four (BR 7.0) different port number can be specified in
PCMCONxx attribute of one BTSM.
If BTSM SW Version changes from a value belonging to BR8.0
release to a value belonging to lower release the CELLTYP
attribute, of the subordinate BTS objects, cannot assume
DBSTDCELL value.
EDTMSUP attribute can be enabled only for those BTSM that
support DTM feature.
UNSUCCESSFUL_INVALID_STATUS
In order to set EXPSWV parameter the BTSM object must be
in LOCKED state.
In order to set EINTSITSYN parameter the BTSM object must
be in the LOCKED state.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The thresholdIdleAbisSU field of the GASTRABISTH attribute
has to be lower or equal than the thresholdIdleAbisRU field and
the thresholdIdleAbisHV field has to be lower or equal than the
thresholdIdleAbisVH field.


348 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
Application Guidelines:
1. The EXPSWV assigned to the BTSM is not handled by the software version of the
BSC. The EXPSWV is present on the BSC disk and the BTSE corresponding to the
BTSM instance is aligned to it by the BSC.
2. An offset of 30 seconds is added to timer SHLAPDIT to manage the links
interruptions.
3. The configuration is not consistent with the HW type of the BTSM; for "hh" and "ii"
see the expected software version Cn-hh-vv-ii-ss-pp_yy-mm-dd coding:
4. The two fields of PCMCONx (x = 1..7) must be both specified or both skipped.
5. BS-242 cannot support GSMR as SYSID (BTS object).
6. BS-242 cannot support extended and concentric cells.
7. BS-242 cannot support base band hopping (HOPMODE of BTS object).
8. Port numbers specified in all the given PCMCONx (x = 1..7) attributes must be com-
patible with the BTS hardware version, as shown in the table below:
The values PORT_2, PORT_4 or PORT_6 can be selected only if the object COSA
is installed; with object COBA installed only the value PORT_0 can be selected.
The hardware object PORT_<n> corresponds to the object BPORT:<n>.
9. At least one PCMCONx must be connected to PORT_0.
BS-2x,
BS-6x
BS-
240/241,
BS-240XL,
BS-4x
BS-82 BS-
240XS
"hh" 01 04 04 04
"ii" 01 05 06
max TRX per
BTSM
2, 6 24 8 6
max TRX per BTS 2, 6 24 8 2
max BTS per
BTSM
2, 3 12 8 3
BTSE type PortNumber
BS-21E, BS-22, BS-20, BS-
60, BS61E
PORT_0, PORT_2
BS-240, BS-241, BS-240XL,
BS-4x, BS-40 II, BS-82 II
PORT_0, PORT_1, PORT_2, PORT_3,
PORT_4, PORT_5, PORT_6, PORT_7
BS-82 PORT_0
BS-240 XS PORT_0, PORT_2


A30808-X3247-M230-6-7619

349
CML:BSC BTSM
Id:0900d805800d4206
10. BS-240XS cannot have SYSID value (see BTS object) equal to GSMDCS,
GSM850PCS or GSM850DCS.
11. All the subordinate to a BS-240XS must have the same frequency range, no mixed
configurations are allowed. The allowed configurations are:
BB900
EXT900
PCS1900
DCS1800
GSMR
GSM850.
12. If the BTSM is a BS-240XS, it is not possible to create for each BTSM a BTS number
greater than 3.
13. If the BTSM is a BS-240XS, it is not possible to create for each subordinate BTS a
TRX number greater than 2.
14. If the BTSM is a BS-240XS, it is not possible to create for each BTSM a TRX number
greater than 6.
15. The AMRHRCi attributes can be set at value RATE_05 (7.40 kbit/s) only if the BTS
HW Version is BTS plus.
Example of Command Execution:
Set BTSM:NAME=BTSM:0,EXPSWV="01-00-01-01-04-04_95-03-01",
SHLAPDIT=3,OMLAPDRT=4,EMT1=20,EMT2=30,SALUNAME="AD042S7449F",
PCMCON0=PCMB_0 -PORT_0,PCMCON1=PCMB_1 -PORT_2,
PCMCON2=PCMB_2-PORT_0,PCMCON3=PCMB_3-PORT_0,PCMCON4=PCMB_4-
PORT_1,PCMCON5=PCMB_4-PORT_1,PCMCON5=PCMB_5-
PORT_1,PCMCON6=PCMB_6-PORT_1,PCMCON7=PCMB_7-PORT_1,FLAPDOV-
LTH=15-10,SLAPDOVLTH=18-12,LAPDOVLT=4,ABISHRACTTHR=60,
ABISTRFHITHR=90,ABISTRFLTHR=80,GASTRABISTH=10-20-15-25, EIN-
TSITSYN=TRUE,ABISMONTH=30-60-90;
SHUTDOWN BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM SHUTDOWN BTSM
Applicability:
Phase 2.
Visibility level: 2.
SHUTDOWN BTSM NAME=BTSM:0..199;


350 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The BSS is able to force a mobile station to perform an intercell or inter-BSC HO by
means of the O&M SHUTDOWN command. After the SHUTDOWN command is
entered, the system tries to perform an intercell or inter-BSC HO per mobile station; in
case of failure, a further attempt is performed every 30 seconds for the next 5 minutes
period.
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

351
CML:BSC BTSM
Id:0900d805800d4206
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes---------->
LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown BTSM:NAME=BTSM:0;
UNLOCK BTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM UNLOCK BTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)
UNLOCK BTSM NAME=BTSM:0..199;


352 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4206
BTSM
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Unlocking of BTSM causes a full BTS alignment.
Example of Command Execution:
Unlock BTSM:NAME=BTSM:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

353
CML:BSC BTSMOSUSW
Id:0900d805800d4209
BTSMOSUSW
The BTSMOSUSW (BTSM Operating Software Unit SW) is used to represent the
operating software resource for BTSM; the OSU objects are used to identify which ESUs
(Executable Software Unit) are operational.
GET BTSMOSUSW
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW GET BTS-
MOSUSW
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
PH phase
System Responses:
- Operation Completed
GET BTSMOSUSW BASICS
GET BTSMOSUSW NAME=BTSM:0..199/BTSMOSUSW:0..0 [,REQATTL=
RUNESU ,BCKUPESU ,PH];
NAME: name
RUNESU: runningESU
BCKUPESU: backupESU
PH: phase
NAME: name
RUNESU: runningESU
BCKUPESU: backupESU
PH: phase


354 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4209
BTSMOSUSW
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET BTSMOSUSW BASICS
None.
Example of Command Execution:
Get BTSMOSUSW:NAME=BTSM:0/BTSMOSUSW:0,
REQATTL=RUNESU& BCKUPESU&PH;
GET BTSMOSUSW BASICS
Get BTSMOSUSW BASICS:NAME=BTSM:0/BTSMOSUSW:0;
GET BTSMOSUSW BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW GET BTS-
MOSUSW BASICS
Applicability:
Phase 2.
Visibility level: 0.
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another in progress.
OBJECT_NOT_FOUND
The referenced object does not exist.
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
GET BTSMOSUSW
BASICS
NAME=BTSM:0..199/BTSMOSUSW:0..0;


A30808-X3247-M230-6-7619

355
CML:BSC BTSMOSUSW
Id:0900d805800d4209
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
PH phase
System Responses:
See GET BTSMOSUSW
Application Guidelines:
See GET BTSMOSUSW
Example of Command Execution:
See GET BTSMOSUSW
GETINFO BTSMOSUSW
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW GETINFO
BTSMOSUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information about the "running" and the
"backup" SW version (all together) for a BTSM network element:
1. For each NEYESUSW corresponding to 'runningESU' attribute:
NEYESUSW instance identifier,
User label associated,
Version number,
Operational state;
2. For each NEYESUSW corresponding to 'backupESU' attribute:
NEYESUSW instance identifier,
User label associated,
Version number,
Operational state;
GETINFO BTSMO-
SUSW
NAME=BTSM:0..199/BTSMOSUSW:0..0;


356 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4209
BTSMOSUSW
3. Information about the load usage state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO BTSMOSUSW ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT BTSMOSUSW:
NAME = BTSMOSUSW:1
RUNNING ESU INSTANCE: 0
USER LABEL: 62BTSMASDAS0024
VERSION: 01-04-14-01-24-00_02-04-25
OPERATIONAL STATE: DISABLED

BACKUP ESU INSTANCE: 0
USER LABEL: 62BTSMXX010024
VERSION: 01-04-14-01-24-00_02-04-25
OPERATIONAL STATE: ENABLED

LOAD USAGE STATE: IDLE
END OF REPORT
- Operation Failed
GETINFO BTSMOSUSW NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack BTSMOSUSW:
name = BTSMOSUSW:1
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

357
CML:BSC BTSMOSUSW
Id:0900d805800d4209
Application Guidelines:
None.
Example of Command Execution:
Getinfo BTSMOSUSW:NAME=BTSM:0/BTSMOSUSW:1;
SETRUNBACK BTSMOSUSW
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTSMOSUSW SETRUN-
BACK BTSMOSUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to perform a "run-back" procedure: with this command the user
sends an "Activate SW" message on A-bis link performing an activation of the new
software on the involved BTS. During this phase the A-bis link falls down so the BTS
goes out of order. When all the software (on BTS) is loaded the A-bis link restarts.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
SETRUNBACK BTS-
MOSUSW
NAME=BTSM:0..199/BTSMOSUSW:0..0;
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
OBJECT_NOT_FOUND
The referenced object instance does not exist.


358 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4209
BTSMOSUSW
Application Guidelines:
The OperationalState attribute of the specific BTSMESUSW must be ENABLED. If the
precondition is not satisfied and/or if the dbVersion required is not stored on BSC disk,
then a specific error collector call is performed.
Example of Command Execution:
Setrunback BTSMOSUSW:NAME=BTSM:0/BTSMOSUSW:0;
INVALID_PARAMETER_NCK
The involved NE attribute does not exist.
The input parameter is out of range.
OBJECT_ALREADY_IN_USE
The command clashes with another in progress.
INCONSISTENT_STATE_NCK
NE activation time-out is expired.
INITIALIZATION_IN_PROGRESS_NCK
An initialization of the system is in progress.
UNSUCCESSFUL_SYS_CALL
A system function call is failed.
UNSUCCESSFUL_OBJ_NOTEQUIPPED
NE is not equipped.
EXPECTED_SWVER_UNDEFINED_NCK
Expected SW version is not defined for NE.
PROCESSING_ERROR_NCK
A function call (for example allocation of memory) fails.
UNSUCCESSFUL_LINK_NOT_AVAIL
The link with NE is not activated.
DOWNLOAD_ALREADY_IN_PROGRESS_NCK
A download of the same NE is already in progress.


A30808-X3247-M230-6-7619

359
CML:BSC CBCL
Id:0900d805800d420c
CBCL
The CBCL object represents the link which connects the RC, through the IXLT, to the
BSC with X.25 protocol.
CREATE CBCL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL CREATE CBCL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds the object CBCL that represents the logical link for the communi-
cation with CBC.
Long Names:
NAME Addres of the managed object
LINKTYPE linkType
X121ADDR x121Addr
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE CBCL NAME=CBCL:0..1 [,LINKTYPE=] [,X121ADDR=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The X25A/X25D (depending on LINKTYPE) object instance
must be already equipped.
The IPLI object must be already equipped if the operator sets
LINKTYPE attribute to the value IPLI.
UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED
The creation of copy #1 is subordinated to the presence of
copy #0.
UNSUCCESSFUL_INVALID_ATTRIBUTES


360 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420c
CBCL
Application Guidelines:
After the creation of the object, the ADMINISTRATIVE state of this object is set at
UNLOCKED. The UNLOCK command is NOT required to put this object in service.
Example of Command Execution:
Create CBCL:NAME=CBCL:0,LINKTYPE=X25A,
X121ADDR=956712345123451234512345123451234;
DELETE CBCL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL DELETE CBCL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the CBCL object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
The X121ADDR attribute must be set to a value different from
NULL if LINKTYPE attribute is set to X25A/X25D.
The X121ADDR attribute cannot be set to a value different
from NULL if LINKTYPE attribute is set to IPLI
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Only one CBCL instance (CBCL:0) can be equipped if the
LINKTYPE attribute is set to IPLI.
DELETE CBCL NAME=CBCL:0..1;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

361
CML:BSC CBCL
Id:0900d805800d420c
Application Guidelines:
None.
Example of Command Execution:
Delete CBCL:NAME=CBCL:0;
GET CBCL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the CBCL object.
Long Names:
NAME Addres of the managed object
CBCLTYPE cbclType
LINKTYPE linkType
X121ADDR x121Addr
System Responses:
- Operation Completed
GET CBCL BASICS
Before deleting a CBCL, the relative object instance must be in
LOCKED state.
UNSUCCESSFUL_COPY_ONE_EQUIPPED
The deletion of the instance #0 is possible only if the copy #1 is
not present.
GET CBCL NAME=CBCL:0..1 [,REQATTL= CBCLTYPE ,LINKTYPE
,X121ADDR];
CBCLTYPE: cbclType
LINKTYPE: linkType
X121ADDR: X121Addr
CBCLTYPE: cbclType
LINKTYPE: linkType


362 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420c
CBCL
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET CBCL BASICS
None.
Example of Command Execution:
Get CBCL:NAME=CBCL:0,REQATTL=CBCLTYPE&LINKTYPE&X121ADDR;
GET CBCL BASICS
Get CBCL BASICS:NAME=CBCL:0;
GET CBCL BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the CBCL object.
Long Names:
NAME Addres of the managed object
CBCLTYPE cbclType
LINKTYPE linkType
System Responses:
See GET CBCL
Application Guidelines:
See GET CBCL
X121ADDR: X121Addr
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET CBCL BASICS NAME=CBCL:0..1;


A30808-X3247-M230-6-7619

363
CML:BSC CBCL
Id:0900d805800d420c
Example of Command Execution:
See GET CBCL
GET CBCL X25INFO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL X25INFO
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the CBCL object.
Long Names:
NAME Addres of the managed object
X121ADDR x121Addr
System Responses:
See GET CBCL
Application Guidelines:
See GET CBCL
Example of Command Execution:
See GET CBCL
GET CBCL STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GET CBCL STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
CBCL object:
Administrative State (AST)
Operational State (OST)
GET CBCL X25INFO NAME=CBCL:0..1;
GET CBCL STAT NAME=CBCL:0..1;


364 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420c
CBCL
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
The handling of the status attributes may be summarized as follows:
The operational state handling may be summarized as follows:
Example of Command Execution:
Get CBCL STAT:NAME=CBCL:0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
Value CBCL
standby PROVIDING
SERVICE
not used
HOTSTANDBY not used
COLDSTANDBY not used
NULL_STATUS not used
availability FAILED CBCL DISABLED layer 3 is down
DEGRADED not used
OFF_DUTY not used
DEPENDENCY X25A/X25D is DISABLED or LOCKED
procedural INITIALIZING not used
CBCL
ENABLED layer 3 up
DISABLED layer 3 down


A30808-X3247-M230-6-7619

365
CML:BSC CBCL
Id:0900d805800d420c
GETRELATIONSHIP CBCL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL GETRELATIONSHIP CBCL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the CBCL object the related HMOs are the following: IXLT, EPWR, PWRD, MPCC
and either X25D (for direct CBC/BSC connection) or X25A, LICD/LICDS, TDPC, MEMT,
NTW+ BSMS, TPWR (for CBC/BSC connection via A interface).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship CBCL:NAME=CBCL:0;
LOCK CBCL
GETRELATIONSHIP
CBCL
NAME=CBCL:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object does not provide any relationship attribute.
LOCK CBCL NAME=CBCL:0..1;


366 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420c
CBCL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL LOCK CBCL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state "Locked" will survive at the Full Init (and consequently to
the load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock CBCL:NAME=CBCL:0;
UNLOCK CBCL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CBCL UNLOCK CBCL
Applicability:
Phase 2.
Visibility level: 1.
ALREADY_IN_TARGET_STATE
The object instance is in administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNLOCK CBCL NAME=CBCL:0..1;


A30808-X3247-M230-6-7619

367
CML:BSC CBCL
Id:0900d805800d420c
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock CBCL:NAME=CBCL:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


368 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
CBTS
The CBTS object provides services the Dynamic MAIO enabling/disabling in all BTSs of
the same BTSM and all the DMA frequencies: It is subordinate to BTSM object.
CREATE CBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS CREATE CBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the instance of the CBTS object.
Long Names:
NAME Addres of the managed object
ENDMA enableDMA
CCALLF01 commonCellAllocationF01
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
CREATE CBTS NAME=BTSM:0..199/CBTS:0..0 [,ENDMA=]
[,CCALLF<nn>=];
Successful
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTSM instance must be already equipped.
INVALID_SVR
Only BTS_plus and BS240XS with SW version at least BR8.0 can
support the CBTS.
UNSUCCESSFUL_INVALID_ATTRIBUTES
At least a CCALLF<nn> must be configured.


A30808-X3247-M230-6-7619

369
CML:BSC CBTS
Id:0900d805800d420f
Application Guidelines:
None.
Example of Command Execution:
Create CBTS:NAME=BTSM:0/CBTS:0,ENDMA=FALSE, CCALLF01=2,CCALLF02=5;
DELETE CBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS DELETE CBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created CBTS.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
The ENDMA parameter can be set to TRUE if there are at least 2
equipped BTSs with ENDMA to TRUE pointing to the same
CFHSY. In case dual band standard cells are present in the site,
this must be valid for both CFHSYs.
The object cannot be created with NETWTYPE GSM-R.
EQUAL_FREQ
The frequencies set at CCALLF<nn> attributes cannot be equal.
FREQ_OUT_OF_RANGE
To set a frequency, the new value must be compatible with the
NETWTYPE of BSC.
DELETE CBTS NAME=BTSM:0..199/CBTS:0..0;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED


370 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
Application Guidelines:
None.
Example of Command Execution:
Delete CBTS:NAME=BTSM:0/CBTS:0;
GET CBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS GET CBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the specified CBTS instance.
Long Names:
NAME Addres of the managed object
ENDMA enableDMA
CCALLF01 commonCellAllocationF01
System Responses:
- Operation Completed
All the BTSs subordinate with DMA enabled must change
configuration or must be deleted.
All the CFHSY instances associated to the CBTS object must
be previously deleted.
GET CBTS NAME=BTSM:0..199/CBTS:0..0 [,REQATTL= ENDMA
,CCALLF<nn>];
NAME: name
ENDMA: enableDMA
CCALLF01:commonCellAllocationF01
CCALLF02:commonCellAllocationF02
CCALLF03:commonCellAllocationF03
CCALLF04:commonCellAllocationF04
CCALLF05:commonCellAllocationF05
CCALLF06:commonCellAllocationF06
CCALLF07:commonCellAllocationF07
CCALLF08:commonCellAllocationF08


A30808-X3247-M230-6-7619

371
CML:BSC CBTS
Id:0900d805800d420f
CCALLF09:commonCellAllocationF09
CCALLF10:commonCellAllocationF10
CCALLF11:commonCellAllocationF11
CCALLF12:commonCellAllocationF12
CCALLF13:commonCellAllocationF13
CCALLF14:commonCellAllocationF14
CCALLF15:commonCellAllocationF15
CCALLF16:commonCellAllocationF16
CCALLF17:commonCellAllocationF17
CCALLF18:commonCellAllocationF18
CCALLF19:commonCellAllocationF19
CCALLF20:commonCellAllocationF20
CCALLF21:commonCellAllocationF21
CCALLF22:commonCellAllocationF01
CCALLF23:commonCellAllocationF23
CCALLF24:commonCellAllocationF24
CCALLF25:commonCellAllocationF25
CCALLF26:commonCellAllocationF26
CCALLF27:commonCellAllocationF27
CCALLF28:commonCellAllocationF28
CCALLF29:commonCellAllocationF29
CCALLF30:commonCellAllocationF30
CCALLF31:commonCellAllocationF31
CCALLF32:commonCellAllocationF32
CCALLF33:commonCellAllocationF33
CCALLF34:commonCellAllocationF34
CCALLF35:commonCellAllocationF35
CCALLF36:commonCellAllocationF36
CCALLF37:commonCellAllocationF37
CCALLF38:commonCellAllocationF38
CCALLF39:commonCellAllocationF39
CCALLF40:commonCellAllocationF40
CCALLF41:commonCellAllocationF41
CCALLF42:commonCellAllocationF42
CCALLF43:commonCellAllocationF43
CCALLF44:commonCellAllocationF44


372 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
GET CBTS BASICS
CCALLF45:commonCellAllocationF45
CCALLF46:commonCellAllocationF46
CCALLF47:commonCellAllocationF47
CCALLF48:commonCellAllocationF48
CCALLF49:commonCellAllocationF49
CCALLF50:commonCellAllocationF40
CCALLF51:commonCellAllocationF51
CCALLF52:commonCellAllocationF52
CCALLF53:commonCellAllocationF53
CCALLF54:commonCellAllocationF54
CCALLF55:commonCellAllocationF55
CCALLF56:commonCellAllocationF56
CCALLF57:commonCellAllocationF57
CCALLF58:commonCellAllocationF58
CCALLF59:commonCellAllocationF59
CCALLF60:commonCellAllocationF60
CCALLF61:commonCellAllocationF61
CCALLF62:commonCellAllocationF62
CCALLF63:commonCellAllocationF63
NAME: name
ENDMA: enableDMA
CCALLF01:commonCellAllocationF01
CCALLF02:commonCellAllocationF02
CCALLF03:commonCellAllocationF03
CCALLF04:commonCellAllocationF04
CCALLF05:commonCellAllocationF05
CCALLF06:commonCellAllocationF06
CCALLF07:commonCellAllocationF07
CCALLF08:commonCellAllocationF08
CCALLF09:commonCellAllocationF09
CCALLF10:commonCellAllocationF10
CCALLF11:commonCellAllocationF11
CCALLF12:commonCellAllocationF12
CCALLF13:commonCellAllocationF13


A30808-X3247-M230-6-7619

373
CML:BSC CBTS
Id:0900d805800d420f
CCALLF14:commonCellAllocationF14
CCALLF15:commonCellAllocationF15
CCALLF16:commonCellAllocationF16
CCALLF17:commonCellAllocationF17
CCALLF18:commonCellAllocationF18
CCALLF19:commonCellAllocationF19
CCALLF20:commonCellAllocationF20
CCALLF21:commonCellAllocationF21
CCALLF22:commonCellAllocationF01
CCALLF23:commonCellAllocationF23
CCALLF24:commonCellAllocationF24
CCALLF25:commonCellAllocationF25
CCALLF26:commonCellAllocationF26
CCALLF27:commonCellAllocationF27
CCALLF28:commonCellAllocationF28
CCALLF29:commonCellAllocationF29
CCALLF30:commonCellAllocationF30
CCALLF31:commonCellAllocationF31
CCALLF32:commonCellAllocationF32
CCALLF33:commonCellAllocationF33
CCALLF34:commonCellAllocationF34
CCALLF35:commonCellAllocationF35
CCALLF36:commonCellAllocationF36
CCALLF37:commonCellAllocationF37
CCALLF38:commonCellAllocationF38
CCALLF39:commonCellAllocationF39
CCALLF40:commonCellAllocationF40
CCALLF41:commonCellAllocationF41
CCALLF42:commonCellAllocationF42
CCALLF43:commonCellAllocationF43
CCALLF44:commonCellAllocationF44
CCALLF45:commonCellAllocationF45
CCALLF46:commonCellAllocationF46
CCALLF47:commonCellAllocationF47
CCALLF48:commonCellAllocationF48
CCALLF49:commonCellAllocationF49


374 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET CBTS BASICS
None.
Example of Command Execution:
Get CBTS:NAME=BTSM:0/CBTS:0,REQATTL=ENDMA&CCALLF01,CCALLF02;
GET CBTS BASICS
Get CBTS BASICS:NAME=BTSM:0;/CBTS:0
GET CBTS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS GET CBTS BASICS
CCALLF50:commonCellAllocationF40
CCALLF51:commonCellAllocationF51
CCALLF52:commonCellAllocationF52
CCALLF53:commonCellAllocationF53
CCALLF54:commonCellAllocationF54
CCALLF55:commonCellAllocationF55
CCALLF56:commonCellAllocationF56
CCALLF57:commonCellAllocationF57
CCALLF58:commonCellAllocationF58
CCALLF59:commonCellAllocationF59
CCALLF60:commonCellAllocationF60
CCALLF61:commonCellAllocationF61
CCALLF62:commonCellAllocationF62
CCALLF63:commonCellAllocationF63
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET CBTS BASICS NAME=BTSM:0..199/CBTS:0..0;


A30808-X3247-M230-6-7619

375
CML:BSC CBTS
Id:0900d805800d420f
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the specified CBTS instance.
Long Names:
NAME Addres of the managed object
ENDMA enableDMA
CCALLF01 commonCellAllocationF01
System Responses:
See GET CBTS
Application Guidelines:
See GET CBTS
Example of Command Execution:
See GET CBTS
GETINFO CBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS GETINFO CBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following information:
1. The report complete indication.
2. The DMA supported indication
3. For each CFHSY:
Moballoc list, i.e. the list of 64 entries with the CCALL (commonCellAllocationF:
list of frequencies inherited from CBTS) information;
DMA MAIO list: list of MAIO used for Dynamic Memory Allocation;
BTS list (with DMA enabled): for each BTS:
layer used for DMA
DMA services: primary or complementary services list (according the type of the
area in which CFHSY is used)
DMA Admission Control Info.
GETINFO CBTS NAME=BTSM:0..199/CBTS:0..0;


376 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
( I ) If enabled DMA=true the following information have reported:
BTS list (with DMA enabled); for each BTS:
- layer used for DMA
-DMA Services: primary or complementary services list (according the type of the area
in which CFHSY is used)
- DMA Admission Control Info
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO CBTS ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT:
NAME = BTSM:1
1REPORT COMPLETE: TRUE
2DMA ENABLED: TRUE
3
4CFHSY 0:
5 MOBALLOC: CCALLF1, CCALLF2, CCALLF3, CCALLF4, CCALLF5,
CCALLF6,
6 CCALLF7, CCALLF8, CCALLF9, CCALLF10, CCALLF11, CCALLF12,
7 CCALLF13, CCALLF14, CCALLF15, CCALLF16, CCALLF17, CCALLF18,
8 CCALLF19, CCALLF20, CCALLF21, CCALLF22, CCALLF23, CCALLF24,
9 CCALLF25, CCALLF26, CCALLF27, CCALLF28, CCALLF29, CCALLF30,
10 CCALLF31, CCALLF32, CCALLF33, CCALLF34, CCALLF35, CCALLF36,
11 CCALLF37, CCALLF38, CCALLF39, CCALLF40, CCALLF41, CCALLF42,
12 CCALLF43, CCALLF44, CCALLF45, CCALLF46, CCALLF47, CCALLF48,
13 CCALLF49, CCALLF50, CCALLF51, CCALLF52, CCALLF53, CCALLF54,
14 CCALLF55, CCALLF56, CCALLF57, CCALLF58, CCALLF59, CCALLF60,
15 CCALLF61, CCALLF62, CCALLF63, CCALLF64
16
17 DMA MAIO: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
18 12, 13, 14, 15, 16, 17
19
20 BTS 0:
21 DMA LAYER: LY3


A30808-X3247-M230-6-7619

377
CML:BSC CBTS
Id:0900d805800d420f
22 PRIMARY SERVICE LIST: CS_EFR_FR_HR, CS_AMR_FR, CS_AMR_HR
23
24 ADMISSION CONTROL:
25 ENABLE SOFT BLOCKING: TRUE
26 MEAN BQP UL: 35.00%
27 MEAN BQP DL: 67.80%
28 MEAN BQP UDL: 31.56%
29 EFL DMA: 100.00%
30
31 BTS 1:
32 DMA LAYER: LY10
33 PRIMARY SERVICE LIST: CS_EFR_FR_HR
34
35 ADMISSION CONTROL:
36 ENABLE SOFT BLOCKING: TRUE
37 MEAN BQP UL: 2.00%
38 MEAN BQP DL: 4.66%
39 MEAN BQP UDL: 24.65%
40 EFL DMA: 3.00%
41
42 BTS 2:
43 DMA LAYER: LY1
44 COMPLEMENTARY SERVICE LIST: CS_AMR_FR
45
46 ADMISSION CONTROL:
47 ENABLE SOFT BLOCKING: FALSE
48 MEAN BQP UL: 56.89%
49 MEAN BQP DL: 24.5%
50 MEAN BQP UDL: 9.00%
51 EFL DMA: 23.35%
52
53 BTS 3:
54 DMA LAYER: LY2
55 PRIMARY SERVICE LIST: CS_EFR_FR_HR, CS_AMR_FR
56
57 ADMISSION CONTROL:
58 ENABLE SOFT BLOCKING: TRUE
59 MEAN BQP UL: 63.45%
60 MEAN BQP DL: 23.45%


378 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
61 MEAN BQP UDL: 6.54%
62 EFL DMA: 4.00%
63
64 BTS 4:
65 DMA LAYER: LY3
66 PRIMARY SERVICE LIST: CS_EFR_FR_HR
67
68 ADMISSION CONTROL:
69 ENABLE SOFT BLOCKING: TRUE
70 MEAN BQP UL: 54.67%
71 MEAN BQP DL: 3.55%
72 MEAN BQP UDL: 57.88%
73 EFL DMA: 53.00%
74
75 BTS 5:
76 DMA LAYER: LY4
77 COMPLEMENTARY SERVICE LIST: CS_AMR_HR
78
79 ADMISSION CONTROL:
80 ENABLE SOFT BLOCKING: FALSE
81 MEAN BQP UL: 35.67%
82 MEAN BQP DL: 45.00%
83 MEAN BQP UDL: 43.78%
84 EFL DMA: 65.00%
85
86 BTS 6:
87 DMA LAYER: LY5
88 PRIMARY SERVICE LIST: CS_EFR_FR_HR
89
90 ADMISSION CONTROL:
91 ENABLE SOFT BLOCKING: TRUE
92 MEAN BQP UL: 5.62%
93 MEAN BQP DL: 7.90%
94 MEAN BQP UDL: 33.22%
95 EFL DMA: 46.00%
96
97 BTS 7:
98 DMA LAYER: LY6
99 PRIMARY SERVICE LIST: CS_AMR_HR


A30808-X3247-M230-6-7619

379
CML:BSC CBTS
Id:0900d805800d420f
100
101 ADMISSION CONTROL:
102 ENABLE SOFT BLOCKING: FALSE
103 MEAN BQP UL: 45.68%
104 MEAN BQP DL: 3.00%
105 MEAN BQP UDL: 46.78%
106 EFL DMA: 35.00%
107
108 BTS 8:
109 DMA LAYER: LY7
110 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR, CS_AMR_FR
111
112 ADMISSION CONTROL:
113 ENABLE SOFT BLOCKING: TRUE
114 MEAN BQP UL: 24.35%
115 MEAN BQP DL: 77.80%
116 MEAN BQP UDL: 98.33%
117 EFL DMA: 4.00%
118
119 BTS 9:
120 DMA LAYER: LY8
121 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
122
123 ADMISSION CONTROL:
124 ENABLE SOFT BLOCKING: TRUE
125 MEAN BQP UL: 2.34%
126 MEAN BQP DL: 54.67%
127 MEAN BQP UDL: 3.43%
128 EFL DMA: 2.00%
129
130 BTS 10:
131 DMA LAYER: LY9
132 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
133
134 ADMISSION CONTROL:
135 ENABLE SOFT BLOCKING: TRUE
136 MEAN BQP UL: 5.55%
137 MEAN BQP DL: 34.44%
138 MEAN BQP UDL: 34.00%


380 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
139 EFL DMA: 2.24%
140
141 BTS 11:
142 DMA LAYER: LY10
143 PRIMARY SERVICE LIST: CS_AMR_HR
144
145 ADMISSION CONTROL:
146 ENABLE SOFT BLOCKING: TRUE
147 MEAN BQP UL: 55.33%
148 MEAN BQP DL: 1.11%
149 MEAN BQP UDL: 1.00%
150 EFL DMA: 11.11%
151
152 BTS 12:
153 DMA LAYER: LY11
154 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR, CS_AMR_FR
155
156 ADMISSION CONTROL:
157 ENABLE SOFT BLOCKING: FALSE
158 MEAN BQP UL: 5.57%
159 MEAN BQP DL: 34.52%
160 MEAN BQP UDL: 79.54%
161 EFL DMA: 3.65%
162
163 BTS 13:
164 DMA LAYER: LY10
165 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
166
167 ADMISSION CONTROL:
168 ENABLE SOFT BLOCKING: TRUE
169 MEAN BQP UL: 36.56%
170 MEAN BQP DL: 34.65%
171 MEAN BQP UDL: 35.00%
172 EFL DMA: 7.00%
173
174 BTS 14:
175 DMA LAYER: LY6
176 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
177


A30808-X3247-M230-6-7619

381
CML:BSC CBTS
Id:0900d805800d420f
178 ADMISSION CONTROL:
179 ENABLE SOFT BLOCKING: TRUE
180 MEAN BQP UL: 68.54%
181 MEAN BQP DL: 56.34%
182 MEAN BQP UDL: 4.00%
183 EFL DMA: 46.54%
184
185 BTS 15:
186 DMA LAYER: LY3
187 PRIMARY SERVICE LIST: CS_EFR_FR_HR
188
189 ADMISSION CONTROL:
190 ENABLE SOFT BLOCKING: FALSE
191 MEAN BQP UL: 23.57%
192 MEAN BQP DL: 37.60%
193 MEAN BQP UDL: 34.60%
194 EFL DMA: 55.00%
195
196 BTS 16:
197 DMA LAYER: LY6
198 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
199
200 ADMISSION CONTROL:
201 ENABLE SOFT BLOCKING: TRUE
202 MEAN BQP UL: 66.76%
203 MEAN BQP DL: 46.54%
204 MEAN BQP UDL: 3.25%
205 EFL DMA: 56.00%
206
207 BTS 17:
208 DMA LAYER: LY10
209 PRIMARY SERVICE LIST: CS_EFR_FR_HR
210
211 ADMISSION CONTROL:
212 ENABLE SOFT BLOCKING: TRUE
213 MEAN BQP UL: 0.24%
214 MEAN BQP DL: 24.67%
215 MEAN BQP UDL: 85.64%
216 EFL DMA: 53.46%


382 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
217
218 BTS 18:
219 DMA LAYER: LY2
220 PRIMARY SERVICE LIST: CS_AMR_HR
221
222 ADMISSION CONTROL:
223 ENABLE SOFT BLOCKING: TRUE
224 MEAN BQP UL: 35.00%
225 MEAN BQP DL: 3.00%
226 MEAN BQP UDL: 67.34%
227 EFL DMA: 7.98%
228
229 BTS 19:
230 DMA LAYER: LY9
231 COMPLEMENTARY SERVICE LIST: CS_AMR_HR
232
233 ADMISSION CONTROL:
234 ENABLE SOFT BLOCKING: TRUE
235 MEAN BQP UL: 42.60%
236 MEAN BQP DL: 56.73%
237 MEAN BQP UDL: 74.35%
238 EFL DMA: 5.00%
239
240 BTS 20:
241 DMA LAYER: LY10
242 PRIMARY SERVICE LIST: CS_EFR_FR_HR
243
244 ADMISSION CONTROL:
245 ENABLE SOFT BLOCKING: TRUE
246 MEAN BQP UL: 4.56%
247 MEAN BQP DL: 54.87%
248 MEAN BQP UDL: 35.00%
249 EFL DMA: 3.68%
250
251 BTS 21:
252 DMA LAYER: LY5
253 PRIMARY SERVICE LIST: CS_EFR_FR_HR
254
255 ADMISSION CONTROL:


A30808-X3247-M230-6-7619

383
CML:BSC CBTS
Id:0900d805800d420f
256 ENABLE SOFT BLOCKING: TRUE
257 MEAN BQP UL: 27.68%
258 MEAN BQP DL: 63.00%
259 MEAN BQP UDL: 57.64%
260 EFL DMA: 36.56%
261
262 BTS 22:
263 DMA LAYER: LY10
264 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
265
266 ADMISSION CONTROL:
267 ENABLE SOFT BLOCKING: TRUE
268 MEAN BQP UL: 34.56%
269 MEAN BQP DL: 34.60%
270 MEAN BQP UDL: 63.00%
271 EFL DMA: 5.00%
272
273 BTS 23:
274 DMA LAYER: LY3
275 COMPLEMENTARY SERVICE LIST: CS_AMR_HR
276
277 ADMISSION CONTROL:
278 ENABLE SOFT BLOCKING: TRUE
279 MEAN BQP UL: 3.25%
280 MEAN BQP DL: 4.52%
281 MEAN BQP UDL: 36.52%
282 EFL DMA: 6.36%
283
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678
901234567890
284CFHSY 1:
285 MOBALLOC: CCALLF1, CCALLF2, CCALLF3, CCALLF4, CCALLF5,
CCALLF6,
286 CCALLF7, CCALLF8, CCALLF9, CCALLF10, CCALLF12, CCALLF13,
287 CCALLF14, CCALLF16, CCALLF60, CCALLF62, CCALLF64
288
289 DMA MAIO: 1, 2, 3
290


384 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
291 BTS 0:
292 DMA LAYER: LY3
293 COMPLEMENTARY SERVICE LIST: CS_AMR_FR, CS_AMR_HR
294
295 ADMISSION CONTROL:
296 ENABLE SOFT BLOCKING: TRUE
297 MEAN BQP UL: 56.32%
298 MEAN BQP DL: 6.00%
299 MEAN BQP UDL: 6.54%
300 EFL DMA: 76.00%
301
302 BTS 1:
303 DMA LAYER: LY10
304 COMPLEMENTARY SERVICE LIST: CS_EFR_FR_HR
305
306 ADMISSION CONTROL:
307 ENABLE SOFT BLOCKING: FALSE
308 MEAN BQP UL: 45.62%
309 MEAN BQP DL: 63.00%
310 MEAN BQP UDL: 6.53%
311 EFL DMA: 7.65%
312
313#x85;.
314
315 BTS 23:
316 DMA LAYER: LY3
317 PRIMARY SERVICE LIST: CS_AMR_HR
318
319 ADMISSION CONTROL:
320 ENABLE SOFT BLOCKING: TRUE
321 MEAN BQP UL: 26.32%
322 MEAN BQP DL: 7.35%
323 MEAN BQP UDL: 76.00%
324 EFL DMA: 7.63%
325
326END OF REPORT
- Operation Failed


A30808-X3247-M230-6-7619

385
CML:BSC CBTS
Id:0900d805800d420f
GETINFO BTSM NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:24:45 2209/1998
*** RESPONSE TO JOB 1***
Get Info Report Nack BTSM:
name = BTSM:1
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo CBTS:NAME=BTSM:0/CBTS:0;
SET CBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS SET CBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the instance of the CBTS object previously created.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the system.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another GetInfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 GetInfo commands already in progress.
SET CBTS NAME=BTSM:0..199/CBTS:0..0 [,ENDMA=]
[,CCALLF<nn>=];


386 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d420f
CBTS
ENDMA enableDMA
CCALLF01 commonCellAllocationF01
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
At least a CCALLF<nn> must be configured different by NULL.
The ENDMA parameter can be set to TRUE if there are at least 2
equipped BTSs with ENDMA to TRUE pointing to the same
CFHSY. In case dual band standard cells are present in the site,
this must be valid for both CFHSYs.
Cannot be set in the same time the ENDMA and the frequencies.
To change the frequencies involved in CFHSY, the ENDMA MUST
BE SET TO false.
The ENDMA cannot be set to FALSE if at least one EAC is set to
TRUE (BTS object).
EQUAL_FREQ
The frequencies set at CCALLF<nn> attributes cannot be equal.
The frequencies set at CCALLF<nn> attribute must be different by
BCCHFREQ and CALLFx of all BTSs that use the CCALLF<nn>.
FREQ_OUT_OF_RANGE
To set a frequency, the new value must be compatible with the
NETWTYPE of BSC.
To set a frequency belonging to the CCALL (BTS object), its value
must remain in the same band of BTS object.
A frequency cannot change range from base to extended band if it
used by a TRX with system indicator EXT900 (BTS object) and with
signalling channels subordinate.
INVALID_STATUS
To change a frequencies used by a BTS, the SCA object, subordi-
nate to BTS, must be in locked state.
To change a ferquency the TRX object, that uses it, must be in
locked state.


A30808-X3247-M230-6-7619

387
CML:BSC CBTS
Id:0900d805800d420f
Application Guidelines:
None.
Example of Command Execution:
Set CBTS:NAME=BTSM:0/CBTS:0,ENDMA=FALSE, CCALLF01=2,CCALLF02=5;
In case of SMA --> DMA transition: ENDMA can be set to TRUE in
the CBTS object only if all the cells with ENDMA=TRUE in the
BTSM are locked.
In case of DMA --> SMA transition: ENDMA can be set to FALSE in
the CBTS object only if all the cells with ENDMA=TRUE in the
BTSM are locked.
NO_MORE_FREQ_AVAILABLE
To set a frequency, used by a BTS, the new value must be con-
tained between the lowest and the highest frequency of the BTS
object.
FREQ_IN_USE
A frequency cannot be set to NULL if it used by a BTS or CFHSY.
OVERLAP_BAND
To set the frequencies belonging to the CMOBALLOC (CFHSY
object), their values must remain in the same sub-band of CFHSY
object.
UNSUCCESSFUL_FREQUENCY_CHANGE_NOT_ALLOWED
A frequency cannot change value from a band to another band if
assigned to a TRX of BTS GSMDCS, GSM850DCS or
GSM850PCS.
UNSUCCESSFUL_DMA_NOT_SUPPORTED
To enable DMA the minimum number of MAIO available for DMA
(2) must be guaranteed.


388 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4212
CFHSY
CFHSY
The CFHSY object defines the DMA hopping laws used by CBTS.
CREATE CFHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS CFHSY CREATE
CFHSY
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the instance of the CFHSY object.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
CMOBALLOC commonMobileAllocation
SUBBAND subordinateBand
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
CREATE CFHSY NAME=BTSM:0..199/CBTS:0..0/CFHSY:0..1 ,HSN=
,CMOBALLOC= ,SUBBAND=;
Successful
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The CBTS instance must be already equipped.
FREQUENCY_NOT_BELONG_TO_CELL
The frequencies into CMOBALLOC attribute must belong to the fre-
quencies assigned to the superordinate CBTS.
OVERLAP_BAND


A30808-X3247-M230-6-7619

389
CML:BSC CFHSY
Id:0900d805800d4212
Application Guidelines:
None.
Example of Command Execution:
Create CFHSY:NAME=BTSM:0/CBTS:0/CFHSY:0,HSN=2,CMOBAL-
LOC=CCALLF03,SUBBAND_PCS1900;
DELETE CFHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS CFHSY DELETE
CFHSY
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created CFHSY.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
The value assigned to SUBBAND attribute must be compatible with
NETWTYPE attribute of BSC object..
The frequencies into CMOBALLOC must belong to the same sub-
band indicates into SUBBAND.
Each instance of CFHSY must belong to a different band
(GSM850+DCS1800, GSM850+PCS1900,
PCS1900+BB900/EB900, DCS1800+BB900/EB900,
BB900+EB900 are allowed).
UNSUCCESSFUL_EQUAL_FREQ
The frequencies into CMOBALLOC attribute cannot be duplicated.
DELETE CFHSY NAME=BTSM:0..199/CBTS:0..0/CFHSY:0..1;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


390 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4212
CFHSY
Application Guidelines:
None.
Example of Command Execution:
Delete CFHSY:NAME=BTSM:0/CBTS:0/CFHSY:0;
GET CFHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS CFHSY GET
CFHSY
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the specified CFHSY instance.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
CMOBALLOC commonMobileAllocation
SUBBAND subordinateBand
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
All CHAN or TRX objects associated to the CFHSY object
must be previously deleted or change configuration.
GET CFHSY NAME=BTSM:0..199/CBTS:0..0/CFHSY:0..1 [,REQATTL=
HSN ,CMOBALLOC ,SUBBAND];
NAME: name
HSN: hoppingSequenceNumber
CMOBALLOC:commonMobileAllocation
SUBBAND:subordinateBand
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

391
CML:BSC CFHSY
Id:0900d805800d4212
Application Guidelines:
None.
Example of Command Execution:
Get CFHSY:NAME=BTSM:0/CBTS:0/CFHSY:0,REQATTL=HSN&CMOBAL-
LOC&SUBBAND;
GET CFHSY BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS CFHSY GET
CFHSY BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the specified CFHSY instance.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
CMOBALLOC commonMobileAllocation
SUBBAND subordinateBand
System Responses:
See GET CFHSY
Application Guidelines:
See GET CFHSY
Example of Command Execution:
See GET CFHSY
SET CFHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM CBTS CFHSY SET
CFHSY
GET CFHSY BASICS NAME=BTSM:0..199/CBTS:0..0/CFHSY:0..1;
SET CFHSY NAME=BTSM:0..199/CBTS:0..0/CFHSY:0..1 [,HSN=]
[,CMOBALLOC=] [,SUBBAND=];


392 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4212
CFHSY
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the instance of the CFHSY object previously created.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
CMOBALLOC commonMobileAllocation
SUBBAND subordinateBand
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must be already created in order to
perform the command.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
To set CMOBALLOC attribute the subordinate channels must not
be equipped.
FREQUENCY_NOT_BELONG_TO_CELL
The frequencies into CMOBALLOC attribute must belong to the fre-
quencies assigned to the superordinate CBTS.
The frequencies into CMOBALLOC must be present into CCALL of
BTSs that use this hopping law.
OVERLAP_BAND
The value assigned to SUBBAND attribute must be compatible with
NETWTYPE attribute of BSC object..
The frequencies into CMOBALLOC must belong to the same sub-
band indicates into SUBBAND.
Each instance of CFHSY must belong to a different band
(GSM850+DCS1800, GSM850+PCS1900,
PCS1900+BB900/EB900, DCS1800+BB900/EB900,
BB900+EB900 are allowed).
The SUBBAND must be compatible with SYSID used by involved
TRX.
HOPPING_ACTIVE


A30808-X3247-M230-6-7619

393
CML:BSC CFHSY
Id:0900d805800d4212
Application Guidelines:
None.
Example of Command Execution:
Set CFHSY:NAME=BTSM:0/CBTS:0/CFHSY:0,HSN=2,CMOBAL-
LOC=CCALLF03,SUBBAND_PCS1900;
To set HSN attribute the hopping must be disabled if subordinate
channels exist.
To change HSN attribute the HOPP attribute, of all BTSs that use
CFHSY, must be FALSE.
EQUAL_FREQ
The frequencies into CMOBALLOC attribute cannot be duplicated.
INVALID_COMMAND
Set of CFHSY can be done only if the ENDMA attribute is set to
FALSE (CBTS object).


394 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
CHAN
The CHAN object represents the radio time slot in which the radio carrier is subdivided
into time sharing; it can be differently configured depending on its usage for the
telephone application software (full rate or half rate traffic channels, dedicated or
common control channels).
CREATE CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN
CREATE CHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command defines a Physical Radio Channel by specifying its attributes which allow
to map Logical Channels onto Physical Radio Channels.
Long Names:
NAME Addres of the managed object
CHTYPE channelCombination
FHSYID frequencyHoppingID
MAIO maio
TSC trainingSequenceCode
EXTMODE extendedMode
GDCH gprsDedicatedChannel
CHPOOLTYP channelPoolType
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7
,CHTYPE= [,FHSYID=] [,MAIO=] [,TSC=] [,EXTMODE=]
[,GDCH=] [,CHPOOLTYP=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.


A30808-X3247-M230-6-7619

395
CML:BSC CHAN
Id:0900d805800d444a
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The TRX which the channel belongs to must be equipped.
FHSY and CFHSY instance pointed by CHAN instance is not
equipped.
UNSUCCESSFUL_BROADCAST_CHAN_NOTEQUIPPED
The channel type of the first channel created in the BTS must
be MAINBCCH, MBCCHC or BCBCH.
UNSUCCESSFUL_INVALID_TIME_SLOT
Make reference to Application Guidelines n. 1, n. 17, n. 21, n.
35, n. 36.
UNSUCCESSFUL_INVALID_CHAN_TYPE
Make reference to Application Guidelines n. 2, n. 3, n. 4, n. 6,
n. 10, n. 16, n. 20, n. 21, n. 22, n. 23, n. 28, n. 29, n. 32, n. 34.
PBCCH cannot be created in EXTENDED cells.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE
If the channel type is SDCCH or SCBCH and the
"sysIndicator" attribute (see BTS object) is EXT900, then the
TRX carrier frequency must belong to the BB900 frequency
band.
UNSUCCESSFUL_TIME_SLOT_ZERO_ALLOCATION
The tsln 0 of a pcmb line is used for synchronism.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set. For more
details see Application Guidelines n. 5, n. 9, n. 24, n. 25,
n. 30, n. 36.
TRXs containing signalling channels (including TCHSD
channels with TCHSD or SDCCH pool) must belong to layers
assigned to the signalling service.
If the BCCH TRX contains GPRS control channels (PBCCH,
PCCCH), its Layer (LY0) must be assigned at least to GPRS
service in case of TRXMD=GSM, at least to EDGE service in
case of TRXMD=EDGE, or to both services.
UNSUCCESSFUL_NO_MORE_SMSCBCH_ALLOWED
Make reference to Application Guideline n. 8.
UNSUCCESSFUL_HOPPING_ACTIVE
Make reference to Application Guideline n. 10.
The hopping must be disabled, to create a channel that use
the frequency hopping law and MAIO set in the superordinate
TRX.


396 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
If the FHSYID is equal to 0 frequency hopping must be
disabled (ENHOPP parameter of the BTS object).
Make reference to Application Guideline n. 29.
The number of channels, with the same time slot number,
pointing to the same FHSY or CFHSY instance can not be
greater than the number of frequencies in the mobile alloca-
tion of the frequency hopping law.
UNSUCCESSFUL_INVALID_MAIO
Make reference to Application Guidelines n. 11, n. 12, n. 23,
n. 27.
A channel must have MAIO and FHSYID different by NULL if
the superordinate TRX has the same attributes set to NULL
(and viceversa).
UNSUCCESSFUL_INVALID_HOPP_GROUP
Make reference to Application Guidelines n. 13, n. 14, n. 23,
n. 27.
The channel cannot to point to CFHSY with some frequen-
cies don't contain into superordinated BTS.
A channel must have MAIO and FHSYID different by NULL if
the superordinate TRX has the same attributes set to NULL
(and viceversa).
UNSUCCESSFUL_OVERLAP_BAND
When the frequency band of the BTS is EXT900 the channel
can use only the Frequency Hopping sequence in the same
band (base or extended) of the superordinate TRX.
The sub-band of CFHSY pointed must be compatible with
system indicator of channel.
The CHAN can point only to a CFHSY or FHSY with frequen-
cies belong to the same band of the CHAN's frequency.
HOPPING_NOT_ALLOWED
In case of synthesizer frequency hopping, it is not allowed to
set the FHSYID of the channel subordinated to the broadcast
TRX at a value different from 0.
If the channel is a PBCCH, it cannot be set to hopping mode.
PREVIOUS_CHAN_DOUBLE
The previous timeslot supports a channel in Extended Mode.
HSCSD_HOPP_INCONSISTENT


A30808-X3247-M230-6-7619

397
CML:BSC CHAN
Id:0900d805800d444a
The attribute BTSHSCSD can be set at TRUE only if the fol-
lowing requirements are satisfied:
1) Case Base Band Hopping Mode:
on every TRX belonging to the layers contained in HSCS-
DLLPRM/HSCSDLLCOM, single TCHs on timeslot from 1 to
7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in HSCS-
DLLPRM/HSCSDLLCOM, different from the BCCH one, all
single TCHs must have the same FHSYD and MAIO.
HSCSD_TSC_INCONSISTENT
If the HSCSD service is activated at BTS side (i.e. attribute
BTSHSCSD of BTS object set at TRUE) the following TSC
requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging
to the layers contained in HSCSDLLPRM/HSCSDLLCOM,
single TCHs on timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in HSCSDLLPRM/HSCSDLLCOM all
single TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
GPRS_TSC_INCONSISTENT


398 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
If the EGPRS flag is set at TRUE in the PTPPKF object the
following TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging
to the layers contained in GLLPRM/GLLCOM, single TCHs
on timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in GLLPRM/GLLCOM all single TCHs
must have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
If the DTMSUP flag is set at TRUE in the PTPPKF object the
following TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging
to the layers shared between Signalling, Circuit and Packet
Services in Primary area, single TCHs on timeslot from 1 to 7
must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging
to the layers shared between Signalling, Circuit and Packet
Services in Primary area all single TCHs must have the same
TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
GPRS_HOPP_INCONSISTENT


A30808-X3247-M230-6-7619

399
CML:BSC CHAN
Id:0900d805800d444a
If the EGPRS flag is set at TRUE in the PTPPKF object the
following TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging
to the layers contained in GLLPRM/GLLCOM, single TCHs
on timeslot from 1 to 7 must have the same FHSYD and
MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in GLL-
PRM/GLLCOM, different from the BCCH one, all single TCHs
must have the same FHSYD and MAIO.
If the DTMSUP flag is set at TRUE in the PTPPKF object the
following TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging
to the layers shared between Signalling, Circuit and Packet
Services in Primary area, single TCHs on timeslot from 1 to 7
must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging
to the layers shared between Signalling, Circuit and Packet
Services in Primary area, different from the BCCH one, all
single TCHs must have the same FHSYD and MAIO.
INVALID_COMMAND
Only one PBCCH can be allocated.
A PCCCH can be allocated only if the PBCCH is already
equipped.
UNSUCCESSFUL_NOT_ENOUGH_SUBTSLB_AVAILABLE
If the SW version running on the superordinate BTSM
belongs to BR6.0 release (see EXPSWV parameter descrip-
tion), namely Abis allocation is 'static', the CREATE CHAN
command is accepted only if at least one free SUBTSLB (not
associated to any CHAN) on a PCMB connecting the BTSM
exists.
EDGE_HOPP_INCONSISTENT


400 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
Application Guidelines:
1. If the channel type is MAINBCCH, MBCCHC, BCBCH, CCCH, SCBCH or SDCCH
(i.e. control channels) then no time slots must be allocated on the pcmb line.
2. If the channel type is MAINBCCH, BCBCH or MBCCHC, then rtsln must be 0.
3. If the channel type is MAINBCCH, BCBCH, MBCCHC or CCCH then the TRX the
channel belongs to must be the broadcast one.
4. If the channel type is MBCCHC or BCBCH, then the parameter NBLKACGR
(noOfBlocksForAccessGrant), which indicates the number of TDMA frames
reserved for the Access Grant channel during a period of 51 TDMA frames, must be
lower than 2; the NBLKACGR parameter is set by the SET BTS command and its
default value is "0".
5. If the channel type is MAINBCCH, MBCCHC, BCBCH, CCCH, SCBCH, SDCCH or
TCH/SD then the attribute TSC must be empty (NULL).
6. The channel CCCH cannot be created if the MBCCHC or BCBCH have already
been configured.
The first CCCH channel must be created on rtsln = 2;
the second CCCH channel must be created on rtsln = 4;
the third CCCH channel must be created on rtsln = 6.
If the EEDGE flag is set at TRUE in the PTPPKF object the
following TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging
to the layers contained in ELLPRM/ELLCOM, single TCHs on
timeslot from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in ELL-
PRM/ELLCOM, different from the BCCH one, all single TCHs
must have the same FHSYD and MAIO.
EDGE_TSC_INCONSISTENT
If the EEDGE flag is set at TRUE in the PTPPKF object the
following TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging
to the layers contained in ELLPRM/ELLCOM, single TCHs on
timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in ELLPRM/ELLCOM, all single TCHs
must have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.


A30808-X3247-M230-6-7619

401
CML:BSC CHAN
Id:0900d805800d444a
7. After the creation of the CHAN object, the ADMINISTRATIVE state of this object is
set at LOCKED. An UNLOCK command is required to put this object in service.
8. Only one BCBCH or SCBCH can be created in a BTS.
9. If FHSY is either equal to 0 or SKIPPED then MAIO is SKIPPED. If FHSY > 0 then
MAIO is NOT SKIPPED.
10. If the channel type is MAINBCCH, MBCCHC, BCBCH or CCCH then the FHSYID
must be equal to 0.
11. CHAN instances, with the same time slot number, pointing to the same FHSY or
CFHSY instance or subordinated to TRXs pointing to the same FHSY or CFHSY
instance, must have different values for MAIO attribute.
12. The value for MAIO attribute must be less than the number of frequencies in the
mobile allocation of the FHSY or CFHSY instance used.
13. CHAN instances, with the same time slot number, can not point to different FHSY
instances if the two FHSY instances use the same frequencies. CHAN instances,
with the same time slot number, cannot have the superordinate TRXs that point to
different FHSY instances if the two FHSY instances use the same frequencies.
14. It is not possible to have one CHAN instance with FHSYID = 0 and another CHAN
instance, with the same time slot number, pointing to a FHSY or CFHSY instance, if
the carrier frequency of superordinate TRX of the first channel is included in the
mobile allocation of FHSY or CFHSY instance pointed by the second.
15. The SCBCH channel can be equipped only on time slots 1, 2, 3 of the BCCH-TRX.
16. If the channel type is SCBCH then the parameter NBLKACGR
(noOfBlocksForAccessGrant attribute, set by the SET BTS command) must not be
equal to 0.
17. When the frequency band of the BTS is EXT900 the channel can use only the Fre-
quency Hopping sequence in the same band (base or extended) of the
superordinate TRX.
18. The creation of a CHAN causes a temporary loss of service for the whole TRX
because of a reset of the associated BBSIG. It is suggested to shutdown the TRX
before creating one or more channels to avoid that calls are dropped.
19. Creation of TCHF_HLF channels must be compatible with the type of hardware used
for TRAU equipment. Only TRAC V3 boards can handle half rate channels coding-
decoding feature.
20. No more than other three channels containing SDCCH subchannels
(i.e. MBCCHC, BCBCH, SCBCH, SDCCH) must belong to the same transceiver.
21. If any channel containing SDCCH subchannels is equipped on a BTS, then at least
one of them must be on the BCCH-TRX.
22. In case of concentric cell the SDCCH channels cannot be created on TRXs with
trxArea parameter set at INNER.
23. In case of concentric cell and base band hopping selected, the attribute FHSYID of
a channel subordinated of a INNER TRX cannot be set with the frequency hopping
system that use frequencies of complete area (and viceversa).


402 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
24. If cellType attribute values EXTCELL all the control and signalling channels must
have EXTMODE=TRUE.
If cellType attribute is different from EXTCELL the EXTMODE attribute cannot be set
at TRUE.
25. The radio timeslot number (rtsln) of an extended channel must be an even one.
26. The timeslot following an extended channel must be not equipped.
27. The extended channels use two consecutive timeslots: therefore, in case of
extended cell, all the previous Application Guidelines regarding frequency hopping
consistency apply also to the timeslot following the channel timeslot.
28. The creation of a SCBCH on a TRX different from BCCH-TRX is allowed only if the
CELLTYPE attribute of the BTS object is set at EXTCELL and at least one CCCH
and one SDCCH have already been configured.
29. It is not allowed to configure the third CCCH channel if the CELLTYPE attribute of
the BTS object is set at EXTCELL.
30. Compatibility between CHTYPE and ASCISER: if ASCISER is equal to
VBSENABLED or VGCSENABLED or VBS_VGCSENABLED:
31. A TCH channel type can be created if at least one of the following conditions is
satisfied:
a SDCCH channel type already exists;
a channel type containing a SDCCH (e.g. a MBCCHC, BCBCH or SCBCH)
already exists.
32. The PBCCH and PCCCH channels must be created on the BCCH-TRX only.
The PBCCH and PCCCH configuration is allowed only for the channel types
TCHFULL and TCHF_HLF as well as TCHSD created with pool type TCHPOOL.
33. All channels on BCCH-TRX must have the same TSC (Training Sequence Code) for
every GPRS activation status (activated or not).
34. GPRS is not supported in the outer area of an extended cell: if the channel is a
GPRS one (PBCCH, PCCCH) than the EXTMODE parameter cannot be set at
TRUE. The inner area of an extended cell supports GPRS.
35. If the EEOTD parameter (see BTS object) is set at TRUE, the TSC value can only
be NULL.
36. A TCHSD channel, with CHPOOLTYP equal to TCHSDPOOL, cannot be used for
GPRS/EDGE traffic. The suggestion is to equip the TCH/SD channels of the "mixed
pool" at the extreme positions inside the TRX (either TS7 or immediately after the
control channels, or TS0 in the not-BCCH carrier). If multiple TCH/SD (mixed pool)
NOCHFBLK NOCHBLKN CHTYPE
1..4 1..4
5 1..3 MAINBCCH
6 1..2
7 1
1..3 1 MBCCHC or BCBCH


A30808-X3247-M230-6-7619

403
CML:BSC CHAN
Id:0900d805800d444a
are requested, they have to be equipped adjacent with the same criteria in grouping
the channels.
Example of Command Execution:
Create CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0,CHTYPE=TCH-
FULL,FHSYID=0,MAIO=0,TSC=2,EXTMODE=FALSE,GDCH=PBCCH,CHPOOL-
TYP=TCHSDPOOL;
DELETE CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN
DELETE CHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a Radio Channel previously created through the CREATE CHAN
command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DELETE CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a CHAN, the relative object instance must be
in LOCKED state.
INVALID_COMMAND
Make reference to Application Guidelines n. 1, n. 3, n. 4, n. 5,
n. 6, n. 7, n. 8.
The last channel that points to a CFHSY cannot be deleted if
ENDMA (BTS Object) is set to TRUE.


404 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
Application Guidelines:
1. If rtsln = 2 and the channel type is CCCH, then it is first necessary to delete the other
CCCH in the TRX;
if rtsln = 4 and the channel type is CCCH then it is first necessary to delete the CCCH
on rtsln = 6 of the same TRX.
2. The deletion of a CHAN causes a temporary loss of service for the whole TRX
because of a reset of the associated BBSIG. It is suggested to shutdown the TRX
before deleting one or more channels to avoid that calls are dropped.
3. The last channel including some SDCCH subchannels equipped on the BCCH-TRX
cannot be deleted if any other SDCCH is equipped on a different TRX on the same
BTS.
4. The last extended or not extended TCH channel cannot be deleted if the intracell
handover for extended cell (attribute EXTCHO of HAND object) is enabled.
5. The broadcast channel cannot be deleted if there are other channels equipped in the
BTS.
6. It is not possible to delete a CCCH channel in an EXTENDED cell with SCBCH
channel equipped.
7. The last SDCCH cannot be deleted if there are traffic channels equipped in the cell.
8. A PBCCH cannot be deleted if some PCCCHs are allocated.
Example of Command Execution:
Delete CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
GET CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GET
CHAN
The DMA in the site must be disabled to delete, in a DMA cell,
the last SMA channel with a MAIO value that doesn't use by
other hopping channels in the site.
UNSUCCESSFUL_SMSCB_USED
The SCBCH and BCBCH channels can be deleted only if the
SMSCBUSE parameter is set at FALSE (SMSCBUSE
parameter of the BTS object).
UNSUCCESSFUL_HOPPING_ACTIVE
The last hopping channel can be deleted only if hopping is
disabled (ENHOPP parameter of the BTS object set at
FALSE).
GET CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7
[,REQATTL= CHTYPE ,FHSYID ,MAIO ,TSC ,EXTMODE
,GDCH ,CHPOOLTYP];


A30808-X3247-M230-6-7619

405
CML:BSC CHAN
Id:0900d805800d444a
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of a CHAN previously created
through the CREATE CHAN command.
Long Names:
NAME Addres of the managed object
CHTYPE channelCombination
FHSYID frequencyHoppingID
MAIO maio
TSC trainingSequenceCode
EXTMODE extendedMode
GDCH gprsDedicatedChannel
CHPOOLTYP channelPoolType
System Responses:
- Operation Completed
GET CHAN BASICS
NAME: name
CHTYPE: channelCombination
FHSYID: frequencyHoppingID
MAIO: maio
TSC: trainingSequenceCode
EXTMODE: extendedMode
GDCH: gprsDedicatedChannel
CHPOOLTYP: channelPoolType
NAME: name
CHTYPE: channelCombination
FHSYID: frequencyHoppingID
MAIO: maio
TSC: trainingSequenceCode
EXTMODE: extendedMode
GDCH: gprsDedicatedChannel
CHPOOLTYP: channelPoolType


406 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET CHAN BASICS
None.
Example of Command Execution:
Get CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0,REQATTL=CHTYPE&
FHSYID&MAIO&TSC&EXTMODE&GDCH&CHPOOLTYP;
GET CHAN BASICS
Get CHAN BASICS:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
GET CHAN BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GET
CHAN BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of a CHAN previously created
through the CREATE CHAN command.
Long Names:
NAME Addres of the managed object
CHTYPE channelCombination
FHSYID frequencyHoppingID
MAIO maio
TSC trainingSequenceCode
EXTMODE extendedMode
GDCH gprsDedicatedChannel
CHPOOLTYP channelPoolType
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET CHAN BASICS NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;


A30808-X3247-M230-6-7619

407
CML:BSC CHAN
Id:0900d805800d444a
System Responses:
See GET CHAN
Application Guidelines:
See GET CHAN
Example of Command Execution:
See GET CHAN
GET CHAN STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN GET
CHAN STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
CHAN object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
GET CHAN STAT NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


408 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
Application Guidelines:
None.
Example of Command Execution:
Get CHAN STAT:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
GETRELATIONSHIP CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN
GETRELATIONSHIP CHAN
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consists of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the CHAN object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW, PPXL and all the BTSE HMOs that implement the TRX
functionality for a certain BTS.
For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR,
GPSU, LI, PA, RXMUCO, RXAMOD and TPU.
For BS-4x/240/241/240XL, the BTSE HMOs are: COBA, COSA, CU, DIDCTMA, DILNA,
DUDCTMA, DULNA, DUVSWR, FVSWRP, FTNFP and TMA.
For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
GETRELATIONSHIP
CHAN
NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES


A30808-X3247-M230-6-7619

409
CML:BSC CHAN
Id:0900d805800d444a
Application Guidelines:
None.
Example of Command Execution:
Getrelationship CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
GETSUBO CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN
GETSUBO CHAN
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end a message is displayed notifying the
end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN: 0;
One or more attributes have been incorrectly set.
GETSUBO CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


410 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
LOCK CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN LOCK
CHAN
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
4. If all traffic channels of a cell are locked, the BSC barres the cell for further access:
the parameter Cell Barred For Access in System Information is set at "cell barred".
5. It is recommended to lock a channel configured as CCCH (by means of the CHTYPE
parameter) only the time strictly necessary to perform configuration change, and to
LOCK CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

411
CML:BSC CHAN
Id:0900d805800d444a
return it in service as soon as possible.The reason is that the LOCK of a CCCH
CHAN does not foresee the
reconfiguration of CCCH groups on remaining CCCHs available. So, when a CCCH
is locked, a MS of the corresponding CCCH group can perform originating calls but
cannot response to terminated calls because the Paging message is not sent on the
LOCKED CCCH.
Example of Command Execution:
Lock CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
SET CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN SET
CHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the attributes of a Physical Radio Channel previously created
through the CREATE CHAN command.
Long Names:
NAME Addres of the managed object
FHSYID frequencyHoppingID
MAIO maio
TSC trainingSequenceCode
GDCH gprsDedicatedChannel
CHPOOLTYP channelPoolType
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
SET CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7
[,FHSYID=] [,MAIO=] [,TSC=] [,GDCH=] [,CHPOOLTYP=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES


412 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
One or more attributes have been incorrectly set. For more details
see Application Guidelines n. 1, n. 2, n. 3.
TRXs containing SDCCH channels (including TCHSD channels
with TCHSD or SDCCH pool) must belong to layers assigned to
the signalling service.
If the BCCH TRX contains GPRS control channels (PBCCH,
PCCCH), its Layer (LY0) must be assigned at least to GPRS
service in case of TRXMD=GSM, at least to EDGE service in case
of TRXMD=EDGE, or to both services.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The FHSY or CFHSY object instance must be already equipped.
UNSUCCESSFUL_HOPPING_ACTIVE
The attributes FHSYID and MAIO can be modified only if the Fre-
quency Hopping is disabled (ENHOPP parameter of the BTS
object must be FALSE).
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The number of channels, with the same time slot number, pointing
to the same FHSY or CFHSY instance can not be greater than the
number of frequencies in the mobile allocation of the frequency
hopping law.
Make reference to Application Guideline n. 9.
UNSUCCESSFUL_INVALID_HOPP_GROUP
Make reference to Application Guidelines n. 4, n. 5, n. 8, n. 9.
The channel cannot to point to CFHSY with some frequencies
don't contain into superordinated BTS.
A channel must have MAIO and FHSYID different by NULL if the
superordinate TRX has the same attributes set to NULL (and vice-
versa).
UNSUCCESSFUL_INVALID_STATUS
Make reference to Application Guidelines n. 6 and n. 7.
UNSUCCESSFUL_INVALID_MAIO
Make reference to Application Guidelines n. 4, n. 5, n. 8, n. 9.
A channel must have MAIO and FHSYID different by NULL if the
superordinate TRX has the same attributes set to NULL (and vice-
versa).
UNSUCCESSFUL_OVERLAP_BAND
When the frequency band of the BTS is EXT900 the channel can
use only the Frequency Hopping sequence in the same band
(base or extended) of the superordinate TRX.
The sub-band of CFHSY pointed must be compatible with system
indicator of channel.


A30808-X3247-M230-6-7619

413
CML:BSC CHAN
Id:0900d805800d444a
The CHAN can point only to a CFHSY or FHSY with frequencies
belong to the same band of the CHAN's frequency.
HOPPING_NOT_ALLOWED
In case of synthesizer frequency hopping, it is not allowed to set
the FHSYID of the channel subordinated to the broadcast TRX at
a value different from 0.
If the channel is a PBCCH, it cannot be set to hopping mode.
HSCSD_HOPP_INCONSISTENT
The attribute BTSHSCSD can be set at TRUE only if the following
requirements are satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM, single TCHs
on timeslot from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to
the layers contained in HSCSDLLPRM/HSCSDLLCOM, different
from the BCCH one, all single TCHs must have the same FHSYD
and MAIO.
HSCSD_TSC_INCONSISTENT
If the HSCSD service is activated at BTS side (i.e. attribute
BTSHSCSD of BTS object set at TRUE) the following TSC require-
ments must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM, single TCHs
on timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM all single
TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
UNSUCCESSFUL_INVALID_CHAN_TYPE
Make reference to Application Guidelines n. 10, n. 11.
PBCCH cannot be created in EXTENDED cells.
GPRS_TSC_INCONSISTENT


414 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
If the EGPRS flag is set at TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM, single TCHs on timeslot
from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM all single TCHs must have
the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
GPRS_HOPP_INCONSISTENT
If the EGPRS flag is set at TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM, single TCHs on timeslot
from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode:
on every TRX belonging to the layers contained in GLL-
PRM/GLLCOM, different from the BCCH one, all single TCHs
must have the same FHSYD and MAIO.
If the DTMSUP flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area, single TCHs on timeslot from 1 to 7 must have the
same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet Services
in Primary area, different from the BCCH one, all single TCHs must
have the same FHSYD and MAIO.
INVALID_COMMAND
Only one PBCCH can be allocated.
A PBCCH can be allocated only if the PBCCH is already equipped.
EDGE_HOPP_INCONSISTENT


A30808-X3247-M230-6-7619

415
CML:BSC CHAN
Id:0900d805800d444a
Application Guidelines:
1. If the channel type is MAINBCCH, MBCCHC, BCBCH, CCCH, SCBCH, SDCCH or
TCH/SD (i.e. control channels) then the attribute TSC must be empty (NULL).
2. The final value for FHSYID and MAIO must belong to one of the following cases:
FHSYID = 0, MAIO = 0
FHSYID > 0, MAIO = 0-63.
3. If the channel type is MAINBCCH, MBCCHC, BCBCH or CCCH, the FHSYID must
be equal to 0.
4. CHAN instances, with the same time slot number, pointing to the same FHSY or
CFHSY instance must have different values for MAIO attribute.
5. The value for MAIO attribute must be less than the number of frequencies in the
mobile allocation of the FHSY or CFHSY instance used.
6. To modify the TSC attribute the CHAN must be put in the locked state.
7. The FHSYID attribute can be modified from 0 to "different from 0 value" only if the
channel is locked.
The FHSYID attribute can be modified from "different from 0 value" to "different from
0 value" only if the two frequency hopping systems have the same HSN, otherwise
the channel must be put in locked state.
If the EEDGE flag is set at TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, single TCHs on timeslot
from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, different from the
BCCH one, all single TCHs must have the same FHSYD and
MAIO.
EDGE_TSC_INCONSISTENT
If the EEDGE flag is set at TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, single TCHs on timeslot
from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, all single TCHs must have
the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.


416 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
8. In case of concentric cell and base band hopping selected, the attribute FHSYID of
a channel subordinated of a INNER TRX cannot be set with the frequency hopping
system that use frequencies of complete area (and viceversa).
9. The extended channels use two consecutive timeslots: therefore, in case of
extended cell, all the previous Application Guidelines regarding frequency hopping
apply also to the timeslot following the channel timeslot.
10. The PBCCH and PCCCH channels must be created on the BCCH-TRX only.
The PBCCH and PCCCH configuration is allowed only for the channel types
TCHFULL and TCHF_HLF as well as TCHSD created with pool type TCHPOOL.
11. GPRS is not supported in the outer area of an extended cell: if the channel is a
GPRS one (PBCCH, PCCCH) than the EXTMODE parameter cannot be set at
TRUE. The inner area of an extended cell supports GPRS.
12. If the EEOTD parameter (see BTS object) is set at TRUE, the TSC value can only
be NULL.
13. A TCHSD channel, with CHPOOLTYP equal to TCHSDPOOL, cannot be used for
GPRS/EDGE traffic. The suggestion is to equip the TCH/SD channels of the "mixed
pool" at the extreme positions inside the TRX (either TS7 or immediately after the
control channels, or TS0 in the not-BCCH carrier). If multiple TCH/SD (mixed pool)
are requested, they have to be equipped adjacent with the same criteria in grouping
the channels.
Example of Command Execution:
Set CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0,FHSYID=<DEFAULT>,
MAIO=<DEFAULT>,TSC=2,GDCH=PBCCH,CHPOOLTYP=TCHSDPOOL;
SHUTDOWN CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN
SHUTDOWN CHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The BSS is able to force a mobile station to perform an intracell, intercell or inter-BSC
HO by means of the O&M SHUTDOWN command. After the SHUTDOWN command is
entered, the system tries to perform an intracell, intercell or inter-BSC HO per mobile
station; in case of failure, a further attempt is performed every 30 seconds for the next
5 minutes period.
SHUTDOWN CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;


A30808-X3247-M230-6-7619

417
CML:BSC CHAN
Id:0900d805800d444a
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ---------->
LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)


418 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d444a
CHAN
UNLOCK CHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CHAN
UNLOCK CHAN
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock CHAN:NAME=BTSM:0/BTS:0/TRX:0/CHAN:0;
UNLOCK CHAN NAME=BTSM:0..199/BTS:0..23/TRX:0..23/CHAN:0..7;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

419
CML:BSC CPCU
Id:0900d805800d4218
CPCU
The CPCU object collects information common to group of PCU serving a BSC service
area.
CREATE CPCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CPCU CREATE CPCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the CPCU object class.
Long Names:
NAME Addres of the managed object
PREAT preallocationTimer
DNLBSSPFCT downloadBSSPFCTimer
MODBSSPFCT modifyBSSPFCTimer
DNLBSSPFCRET downloadBSSPFCRetries
MODBSSPFCRET modifyBSSPFCRetries
NBVCBR numberOfBvcBlockRetries
NBVCUR numberOfBvcUnblockRetries
NBVCRR numberOfBvcResetRetries
T1 timerT1
T2 t2
TF1 tf1
N3101 n3101
N3103 n3103
N3105 n3105
NRLCMAX numberRlcMax
CREATE CPCU NAME=CPCU:0..11 [,PREAT=] [,DNLBSSPFCT=] [,MODB-
SSPFCT=] [,DNLBSSPFCRET=] [,MODBSSPFCRET=]
[,NBVCBR=] [,NBVCUR=] [,NBVCRR=] [,T1=] [,T2=] [,TF1=]
[,N3101=] [,N3103=] [,N3105=] [,NRLCMAX=] [,T3141=]
[,T3169=] [,T3172=] [,T3191=] [,T3193=] [,T3195=]
[,TEMPCH=] [,TIMEDTBFREL=] [,TEMPPDT=] [,THSUL-
BAL=] [,TSULBAL=] [,UPGRFREQ=] [,SISGSNREL99=]
,TH= ,TF= [,FCRATE=] [,T3=] [,T4=] [,TPFCBUFF=] [,T5=]
[,NRACPBLUPDRET=] [,TEXTULTBF=];


420 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4218
CPCU
T3141 t3141
T3169 t3169
T3172 t3172
T3191 t3191
T3193 t3193
T3195 t3195
TEMPCH timerEmptyChannel
TIMEDTBFREL timeDelayTBFRelease
TEMPPDT timerEmptyPDT
THSULBAL thresholdSwitchULBalanced
TSULBAL timeSwitchULBalanced
UPGRFREQ UpgradeFrequency
SISGSNREL99 systemInfoSgsnRelease99
TH tH
TF tF
FCRATE lowPassFilterCoefficientLeakRate
T3 timer3
T4 timer4
TPFCBUFF timerPFCBuffer
T5 T5
NRACPBLUPDRET numberRaCapabilityUpdateRetries
TEXTULTBF timeExtendedUplinkTBF
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESFUL_OBJECT_ALREADY_EQUIPPED
The instance of the Common PCU must not be already created.
FEATURE_NOT_RELEASED
The creation of CPCU instances greather than 0 is not supported by
current software loading version.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The TEMPPDT attribute value must be lower than the TEMPCH attribute
value.
The TH attribute cannot be set to a value lower than TF1.
The TF attribute cannot be set to a value lower than TF1.
UNSUCCESSFUL_EXCEEDED_OBJECT_NBR


A30808-X3247-M230-6-7619

421
CML:BSC CPCU
Id:0900d805800d4218
Application Guidelines:
In case of trouble on redundant NSVC links created on the Gb interface, it could happen
that PTPPKF object is disabled while NSVC is still enabled. In order to avoid this situa-
tion the following rule has to be followed:
TF1*"number of flow control retries" > TNSVCTST + TNSVCPTST*NNSVCTSTR.
The "number fo flow control retries" is not manageable by operator and is fixed to 15.
Default values of all the above attributes are in according with the rule.
Example of Command Execution:
Create
CPCU:NAME=CPCU:0,NBVCBR=12,NBVCUR=21,NBVCRR=14,T1=4,T2=6,TF1=50,
N3101=32,N3103=23,N3105=23,NRLCMAX=25,T3141=24,T3169=4,T3172=10,
T3191=9,T3193=4,T3195=20,T3=50, T4=10, TEMPCH=45,TIMEDTBFREL=15,TEMP-
PDT=15, THSULBAL =1000, TSULBAL = 50, UPGRFREQ=SEC1-SEC1,
SISGSNREL99=FALSE , DNLBSSPFCT=100, MODBSSPFCT=100, DNLBSSPF-
CRET=3 , MODBSSPFCRET= 3, PREAT=20, T5=5, NRACPBLUPDRET=10,
TEXTULTBF=15, TH=51, TF=53, FCRATE=100, TPFCBUFF=20;
DELETE CPCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CPCU DELETE CPCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the CPCU object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
In case of old rack only CPCU instances 0..5 are allowed.
DELETE CPCU NAME=CPCU:0..11;
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
Related PCU existing.


422 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4218
CPCU
Application Guidelines:
None.
Example of Command Execution:
Delete CPCU:NAME=CPCU:0;
GET CPCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CPCU GET CPCU
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the CPCU
object class.
Long Names:
NAME Addres of the managed object
PREAT preallocationTimer
DNLBSSPFCT downloadBSSPFCTimer
MODBSSPFCT modifyBSSPFCTimer
DNLBSSPFCRET downloadBSSPFCRetries
MODBSSPFCRET modifyBSSPFCRetries
NBVCBR numberOfBvcBlockRetries
NBVCUR numberOfBvcUnblockRetries
NBVCRR numberOfBvcResetRetries
T1 timerT1
T2 t2
TF1 tf1
N3101 n3101
Related PTPPKF existing.
GET CPCU NAME=CPCU:0..11 [,REQATTL= PREAT ,DNLBSSPFCT
,MODBSSPFCT ,DNLBSSPFCRET ,MODBSSPFCRET
,NBVCBR ,NBVCUR ,NBVCRR ,T1 ,T2 ,TF1 ,N3101 ,N3103
,N3105 ,NRLCMAX ,T3141 ,T3169 ,T3172 ,T3191 ,T3193
,T3195 ,TEMPCH ,TIMEDTBFREL ,TEMPPDT ,THSULBAL
,TSULBAL ,UPGRFREQ ,SISGSNREL99 ,TH ,TF ,FCRATE
,T3 ,T4 ,TPFCBUFF ,T5 ,NRACPBLUPDRET
,TEXTULTBF];


A30808-X3247-M230-6-7619

423
CML:BSC CPCU
Id:0900d805800d4218
N3103 n3103
N3105 n3105
NRLCMAX numberRlcMax
T3141 t3141
T3169 t3169
T3172 t3172
T3191 t3191
T3193 t3193
T3195 t3195
TEMPCH timerEmptyChannel
TIMEDTBFREL timeDelayTBFRelease
TEMPPDT timerEmptyPDT
THSULBAL thresholdSwitchULBalanced
TSULBAL timeSwitchULBalanced
UPGRFREQ UpgradeFrequency
SISGSNREL99 systemInfoSgsnRelease99
TH tH
TF tF
FCRATE lowPassFilterCoefficientLeakRate
T3 timer3
T4 timer4
TPFCBUFF timerPFCBuffer
T5 T5
NRACPBLUPDRET numberRaCapabilityUpdateRetries
TEXTULTBF timeExtendedUplinkTBF
System Responses:
- Operation Completed
NBVCBR: NumberOfBvcBlockRetries
NBVCUR: NumberOfBvcUnblockRetries
NBVCRR: NumberOfBvcResetRetries
T1: t1
T2: t2
TF1: tf1
T3: t3
T4: t4
THSULBAL thresholdSwitchULBalanced
TSULBAL timeSwitchULBalanced


424 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4218
CPCU
- Operation Failed
NACK CAUSES:
N3101: n3101
N3103: n3103
N3105 n3105
NRLCMAX numberRlcMax
T3141 t3141
T3169: t3169
T3172: t3172
T3191: t3191
T3193: t3193
T3195: t3195
TEMPCH: TimerEmptyChannel
TIMEDTBFREL: timeDelayTBFRelease
TEMPPDT: timerEmptyPDT
SISGSNREL99: systemInfoSgsnRelease99
UPGRFREQ: UpgradeFrequency
Uplink
Downlink
PREAT: preallocationTimer
DNLBSSPFCT: downloadBSSPFCTimer
MODBSSPFCT: modifyBSSPFCTimer
DNLBSSPFCRET: downloadBSSPFCRetries
MODBSSPFCRET: modifyBSSPFCRetries
T5: t5
NRACPBLUPDRET: numberRaCapabilityUpdateRetries
TEXTULTBF: timeExtendedUplinkTBF
TH: Th
TF: Tf
FCRATE: lowPassFilterCoefficientLeakRate
TPFCBUFF: timerPFCBuffer
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the Common PCU is not already
created.


A30808-X3247-M230-6-7619

425
CML:BSC CPCU
Id:0900d805800d4218
Application Guidelines:
None.
GET CPCU STAT
None.
Example of Command Execution:
Get
CPCU:NAME=CPCU:0,REQAATL=NBVCBR&&NBVCUR&NBVCRR&T1&T2&TF1&
N3101&N3103&N3105&NRLC-
MAX&T3141&T3169&T3172&&T3191&T3193&T3195&T3&T4&TEMPCH&TIMEDTB-
FREL&TEMPPDT&THSULBAL&TSULBAL&UPGRFREQ&
SISGSNREL99&DNLBSSPFCT&MODBSSPFCT&DNLBSSPFCRET&MODBSSPF-
CRET&PREAT&T5&NRACPBLUP-
DRET&TEXTULTBF&TF&TH&FCRATE&TPFCBUFF;
GET CPCU STAT
Get CPCU STAT:NAME=CPCU:0;
GET CPCU BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CPCU GET CPCU BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the CPCU
object class.
Long Names:
NAME Addres of the managed object
PREAT preallocationTimer
DNLBSSPFCT downloadBSSPFCTimer
MODBSSPFCT modifyBSSPFCTimer
DNLBSSPFCRET downloadBSSPFCRetries
MODBSSPFCRET modifyBSSPFCRetries
NBVCBR numberOfBvcBlockRetries
NBVCUR numberOfBvcUnblockRetries
NBVCRR numberOfBvcResetRetries
GET CPCU BASICS NAME=CPCU:0..11;


426 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4218
CPCU
T1 timerT1
T2 t2
TF1 tf1
N3101 n3101
N3103 n3103
N3105 n3105
NRLCMAX numberRlcMax
T3141 t3141
T3169 t3169
T3172 t3172
T3191 t3191
T3193 t3193
T3195 t3195
TEMPCH timerEmptyChannel
TIMEDTBFREL timeDelayTBFRelease
TEMPPDT timerEmptyPDT
THSULBAL thresholdSwitchULBalanced
TSULBAL timeSwitchULBalanced
UPGRFREQ UpgradeFrequency
SISGSNREL99 systemInfoSgsnRelease99
TH tH
TF tF
FCRATE lowPassFilterCoefficientLeakRate
T3 timer3
T4 timer4
TPFCBUFF timerPFCBuffer
T5 T5
NRACPBLUPDRET numberRaCapabilityUpdateRetries
TEXTULTBF timeExtendedUplinkTBF
System Responses:
See GET CPCU
Application Guidelines:
See GET CPCU
Example of Command Execution:
See GET CPCU


A30808-X3247-M230-6-7619

427
CML:BSC CPCU
Id:0900d805800d4218
SET CPCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CPCU SET CPCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the CPCU object class.
Long Names:
NAME Addres of the managed object
PREAT preallocationTimer
DNLBSSPFCT downloadBSSPFCTimer
MODBSSPFCT modifyBSSPFCTimer
DNLBSSPFCRET downloadBSSPFCRetries
MODBSSPFCRET modifyBSSPFCRetries
NBVCBR numberOfBvcBlockRetries
NBVCUR numberOfBvcUnblockRetries
NBVCRR numberOfBvcResetRetries
T1 timerT1
T2 t2
TF1 tf1
N3101 n3101
N3103 n3103
N3105 n3105
NRLCMAX numberRlcMax
T3141 t3141
T3169 t3169
T3172 t3172
T3191 t3191
SET CPCU NAME=CPCU:0..11 [,PREAT=] [,DNLBSSPFCT=] [,MODB-
SSPFCT=] [,DNLBSSPFCRET=] [,MODBSSPFCRET=]
[,NBVCBR=] [,NBVCUR=] [,NBVCRR=] [,T1=] [,T2=] [,TF1=]
[,N3101=] [,N3103=] [,N3105=] [,NRLCMAX=] [,T3141=]
[,T3169=] [,T3172=] [,T3191=] [,T3193=] [,T3195=]
[,TEMPCH=] [,TIMEDTBFREL=] [,TEMPPDT=] [,THSUL-
BAL=] [,TSULBAL=] [,UPGRFREQ=] [,SISGSNREL99=]
[,TH=] [,TF=] [,FCRATE=] [,T3=] [,T4=] [,TPFCBUFF=] [,T5=]
[,NRACPBLUPDRET=] [,TEXTULTBF=];


428 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4218
CPCU
T3193 t3193
T3195 t3195
TEMPCH timerEmptyChannel
TIMEDTBFREL timeDelayTBFRelease
TEMPPDT timerEmptyPDT
THSULBAL thresholdSwitchULBalanced
TSULBAL timeSwitchULBalanced
UPGRFREQ UpgradeFrequency
SISGSNREL99 systemInfoSgsnRelease99
TH tH
TF tF
FCRATE lowPassFilterCoefficientLeakRate
T3 timer3
T4 timer4
TPFCBUFF timerPFCBuffer
T5 T5
NRACPBLUPDRET numberRaCapabilityUpdateRetries
TEXTULTBF timeExtendedUplinkTBF
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. In case of trouble on redundant NSVC links created on the Gb interface, it could
happen that PTPPKF object is disabled while NSVC is still enabled. In order to avoid this
situation the following rule has to be followed:
TF1*"number of flow control retries" > TNSVCTST + TNSVCPTST*NNSVCTSTR.
The "number fo flow control retries" is not manageable by operator and is fixed to 15.
Default values of all the above attributes are in according with the rule.
OBJECT_NOTEQUIPPED
The instance of the Common PCU is not already
created.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The TEMPPDT attribute value must be lower than the
TEMPCH attribute value.
The TH attribute cannot be set to a value lower than TF1.
The TF attribute cannot be set to a value lower than TF1.


A30808-X3247-M230-6-7619

429
CML:BSC CPCU
Id:0900d805800d4218
Example of Command Execution:
Set
CPCU:NAME=CPCU:0,NBVCBR=12,NBVCUR=21,NBVCRR=14,T1=4,T2=6,TF1=50,
N3101=32,N3103=23,N3105=23,NRLCMAX=25,T3141=24,T3169=4,T3172=10,
T3191=9,T3193=4,T3195=20,T3=50, T4=10, TEMPCH=45,TIMEDTBFREL=15,TEMP-
PDT=15, THSULBAL =1000, TSULBAL = 50, UPGRFREQ=SEC1-SEC1,
SISGSNREL99=FALSE , DNLBSSPFCT=100, MODBSSPFCT=100, DNLBSSPF-
CRET=3 , MODBSSPFCRET= 3, PREAT=20, T5=5, NRACPBLUPDRET=10,
TEXTULTBF=15,TH=51, TF=53, FCRATE=100, TPFCBUFF=20;


430 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d421b
CPEX
CPEX
The CPEX (Control Panel and External alarms device) is the card which reports to
MPCC 16 external alarms and the FAN alarm and controls the fuse and alarm panel.
It is redounded 1 + 1.
GET CPEX STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GET CPEX STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
CPEX object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CST)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get CPEX STAT:NAME=CPEX:0;
GET CPEX STAT NAME=CPEX:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

431
CML:BSC CPEX
Id:0900d805800d421b
GETRELATIONSHIP CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GETRELATIONSHIP
CPEX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.

Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship CPEX:NAME=CPEX:0;
GETSUBO CPEX
GETRELATIONSHIP
CPEX
NAME=CPEX:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
GETSUBO CPEX NAME=CPEX:0..1;


432 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d421b
CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GETSUBO CPEX
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo CPEX:NAME=CPEX:0;
GETTEST CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX GETTEST CPEX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETTEST CPEX NAME=CPEX:0..1;


A30808-X3247-M230-6-7619

433
CML:BSC CPEX
Id:0900d805800d421b
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest CPEX:NAME=CPEX:0;
LOCK CPEX
GETTEST CPEX:NAME=CPEX:0;
name = TEST:<n>
mOts = CPEX:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK CPEX NAME=CPEX:0..1;


434 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d421b
CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX LOCK CPEX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state LOCKED.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects but MPCC, IXLT, PWRD,
TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock CPEX:NAME=CPEX:0;
PERFTEST CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX PERFTEST CPEX
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The selected object is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PERFTEST CPEX NAME=CPEX:0..1;


A30808-X3247-M230-6-7619

435
CML:BSC CPEX
Id:0900d805800d421b
Command Description:
This command is used to perform a test on the selected CPEX object; the test consists
of the following phases:
Accessibility Test (start phase),
FAN alarm force (WP1),
ENVA alarm force (WP2),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST CPEX:NAME=CPEX:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases


436 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d421b
CPEX
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest CPEX:NAME=CPEX:0;
STOPTEST CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX STOPTEST CPEX
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
STOPTEST CPEX NAME=CPEX:0..1;


A30808-X3247-M230-6-7619

437
CML:BSC CPEX
Id:0900d805800d421b
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that executes the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STOPTEST CPEX:NAME=CPEX:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = CPEX:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST


438 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d421b
CPEX
Application Guidelines:
None.
Example of Command Execution:
Stoptest CPEX:NAME=CPEX:0;
UNLOCK CPEX
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE CPEX UNLOCK CPEX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state UNLOCKED.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the CPEX card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock CPEX:NAME=CPEX:0;
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNLOCK CPEX NAME=CPEX:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

439
CML:BSC CTRCO
Id:0900d805800d4222
CTRCO
The CTRCO (CTR Control) object controls the Cell Traffic Recording (CTR) tracing
activities within a BSS.
GET CTRCO STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO GET CTRCO STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
CTRCO object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
None
Application Guidelines:
None.
Example of Command Execution:
Get CTRCO STAT:NAME=CTRCO:0;
GET CTRCO STAT NAME=CTRCO:0..0;


440 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4222
CTRCO
GETINFO CTRCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO GETINFO CTRCO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the whole set of information regarding the CTRCO
instance active in the system. The information recovered are:
1. The report complete indication
2. The states of the CTRCO: AST, OST, UST.
3. Trace measurement flag
4. Granularity of time for trace measurement set by operator
5. Granularity of time for trace measurement calculated by the system
6. Maximum size of CTR file
7. For each active CTRSCHED the following information are given:
CTRSCHED instance
BTSM instance
BTS instance
Number of active connections
Max number of available connections
Trace channel type: TCH, SDCCH or BOTH
AST,OST state and AVL status
Number of CTR sched elapsed
Type of record
Start time
Size of record.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO CTRCO ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GETINFO CTRCO NAME=CTRCO:0..0;


A30808-X3247-M230-6-7619

441
CML:BSC CTRCO
Id:0900d805800d4222
GETINFO REPORT CTRCO:
NAME = CTRCO:0
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
USAGE STATE: IDLE
TRACEMR: TRUE
TRACEMG: 5
REALTRG: 8
MAX CTR FILE SIZE: 6 MBYTES
LIST OF ALL CTRSCHED OBJECT:
CTR# BTSM# BTS# ACTIVE CONNECTION MAX CONNECTION TRACECH
0 2 118 1 5 SDCCH
1 6 117 0 16 TCH
...; ...; ...; ...; ...; ...;
31 12 109 28 128 BOTH
CTR# ADMINISTRATIVE STATE OPERATIONAL STATE AVAIL OFF DUTY
0 UNLOCKED ENABLED RESET
1 UNLOCKED ENABLED NONE
... ...; ...; ...;
31 UNLOCKED ENABLED NONE
CTR# ELAPSED TYPE RECORD TYPE START TIME SIZE (KBYTE)
0 0 ALL 31:Mar:2000 14:44:00 12
1 0 MESSAGE 31:Mar:2000 14:48:01 30
...; ...; ...; ...; ...;
31 0 ALL 31:Mar:2000 16:49:03 22
END OF REPORT
- Operation Failed
GETINFO CTRCO NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:24:45 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack CTRCO:


442 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4222
CTRCO
name = CTRCO:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo CTRCO:NAME=CTRCO:0;
LOCK CTRCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO LOCK CTRCO
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
LOCK CTRCO NAME=CTRCO:0..0;
ALREADY_IN_TARGET_STATE


A30808-X3247-M230-6-7619

443
CML:BSC CTRCO
Id:0900d805800d4222
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock CTRCO:NAME=CTRCO:0;
UNLOCK CTRCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO UNLOCK CTRCO
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock CTRCO:NAME=CTRCO:0;
The selected object is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNLOCK CTRCO NAME=CTRCO:0..0;
ALREADY_IN_TARGET_STATE
The selected object is in the administrative state UNLOCKED.


444 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4222
CTRCO
UPLALLCELLTR CTRCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO UPLALLCELLTR CTRCO
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows to upload, from BSC disk to LMT disk, the information related to
the CTR tracing activities related to all cells.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
Uplallcelltr CTRCO:NAME=CTRCO:0,DESTDIR="C:\Siemens\Trace",
OVERWRITE=YES;
UPLALLCELLTR
CTRCO
NAME=CTRCO:0..0 ,DESTDIR= ,OVERWRITE=;
DIRECTORY_NOT_FOUND
FILE_NOT_FOUND


A30808-X3247-M230-6-7619

445
CML:BSC CTRCO
Id:0900d805800d4222
UPLCELLTR CTRCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO UPLCELLTR CTRCO
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows to upload, from BSC disk to LMT disk, the information related to
the CTR tracing activities related the cell defined by means of the CID parameter.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
CID cellIdentity
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
Uplcelltr CTRCO:NAME=CTRCO:0,DESTDIR="C:\Trace", OVERWRITE=NO,
CID=BTSM:0/BTS:0;
UPLCELLTR CTRCO NAME=CTRCO:0..0 ,DESTDIR= ,OVERWRITE= ,CID=;
DIRECTORY_NOT_FOUND
FILE_NOT_FOUND


446 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4225
CTRSCHED
CTRSCHED
The CTRSCHED (CTR Scheduler) object provides the schedulation of the Cell Traffic
Recording (CTR) tracing activities within a BSS.
CREATE CTRSCHED
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED CREATE
CTRSCHED
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the CTRSCHED object class.
Long Names:
NAME Addres of the managed object
CID cellIdentity
MACONN maxConnectionNumber
START startDate
STOP stopDate
PERWEEK periodWeekly
TRACERECTYP traceRecordType
TRACECH tracedChannel
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE CTRSCHED NAME=CTRCO:0..0/CTRSCHED:0..31 ,CID= ,MACONN=
[,START=] [,STOP=] ,PERWEEK= ,TRACERECTYP=
[,TRACECH=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The attribute CID must refer to an equipped cell.
UNSUCCESSFUL_TOO_MANY_TRACES


A30808-X3247-M230-6-7619

447
CML:BSC CTRSCHED
Id:0900d805800d4225
Application Guidelines:
1. The STOP attribute must be set at a value greater or equal to the value of START.
2. If a cell is configured in a CTRSCHED instance, all subsequent CREATE
CTRSCHED commands, related to the same cell, shall be rejected if the scheduled
periods overlapped.
Example of Command Execution:
CreateCTRSCHED:NAME=CTRCO:0/CTRSCHED:0,CID=BTSM:0/BTS:0,
MACONN=128, START=2-1-2001,STOP=2-3-2003,PERWEEK=weekly((noSched(0)-
noSched(0)-noSched(0)-wePeriod((3-50-14-00))-noSched(0)-noSched(0)-
noSched(0))),TRACERECTYP=All,TRACECH=BOTH;
DELETE CTRSCHED
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED DELETE
CTRSCHED
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the CTRSCHED object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
The maximum number of connections traceable in a BSS,
considering all the scheduled periods, is exceeded.
UNSUCCESSFUL_CELL_ALREADY_TRACED
In the same cell there must be no periods, overlapping.
INVALID_COMMAND
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
DELETE CTRSCHED NAME=CTRCO:0..0/CTRSCHED:0..31;


448 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4225
CTRSCHED
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete CTRSCHED:NAME=CTRCO:0/CTRSCHED:0;
GET CTRSCHED
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED GET
CTRSCHED
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
CTRSCHED object class.
Long Names:
NAME Addres of the managed object
CID cellIdentity
MACONN maxConnectionNumber
START startDate
STOP stopDate
PERWEEK periodWeekly
TRACERECTYP traceRecordType
LSUPDTIME lastUpdTime
TRACECH tracedChannel
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a CTRSCHED, the relative object
instance must be in LOCKED state..
GET CTRSCHED NAME=CTRCO:0..0/CTRSCHED:0..31 [,REQATTL= CID
,MACONN ,START ,STOP ,PERWEEK ,TRACERECTYP
,LSUPDTIME ,TRACECH];


A30808-X3247-M230-6-7619

449
CML:BSC CTRSCHED
Id:0900d805800d4225
System Responses:
- Operation Completed
GET CTRSCHED BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET CTRSCHED BASICS
None.
Example of Command Execution:
Get CTRSCHED:NAME=CTRCO:0/CTRSCHED:0,REQATTL=CID&MACONN&
START&STOP&PERWEEK&TRACERECTYP&LSUPDTIME&TRACECH;
GET CTRSCHED BASICS
Get CTRSCHED BASICS:NAME=CTRCO:0/CTRSCHED:0;
CID. CellIdentity
MACONN. maxConnectionNumber
START: startDate
STOP: stopDate
PERWEEK: periodWeekly
TRACERECTYP: traceRecordType
LSUPDTIME: lastUpdTime
TRACECH: tracedChannel
CID: CellIdentity
MACONN: maxConnectionNumber
START: startDate
STOP: stopDate
PERWEEK: periodWeekly
TRACERECTYP: traceRecordType
TRACECH: tracedChannel
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


450 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4225
CTRSCHED
GET CTRSCHED BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED GET
CTRSCHED BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
CTRSCHED object class.
Long Names:
NAME Addres of the managed object
CID cellIdentity
MACONN maxConnectionNumber
START startDate
STOP stopDate
PERWEEK periodWeekly
TRACERECTYP traceRecordType
LSUPDTIME lastUpdTime
TRACECH tracedChannel
System Responses:
See GET CTRSCHED
Application Guidelines:
See GET CTRSCHED
Example of Command Execution:
See GET CTRSCHED
GET CTRSCHED STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED GET
CTRSCHED STAT
GET CTRSCHED
BASICS
NAME=CTRCO:0..0/CTRSCHED:0..31;
GET CTRSCHED STAT NAME=CTRCO:0..0/CTRSCHED:0..31;


A30808-X3247-M230-6-7619

451
CML:BSC CTRSCHED
Id:0900d805800d4225
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
CTRSCHED object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get CTRSCHED STAT:NAME=CTRCO:0/CTRSCHED:0;
LOCK CTRSCHED
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED LOCK
CTRSCHED
Applicability:
Phase 2.
Visibility level: 1.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK CTRSCHED NAME=CTRCO:0..0/CTRSCHED:0..31;


452 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4225
CTRSCHED
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock CTRSCHED:NAME=CTRCO:0/CTRSCHED:0;
SET CTRSCHED
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED SET
CTRSCHED
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the CTRSCHED object class.
ALREADY_IN_TARGET_STATE
The selected object is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET CTRSCHED NAME=CTRCO:0..0/CTRSCHED:0..31 [,CID=]
[,MACONN=] [,START=] [,STOP=] [,PERWEEK=] [,TRAC-
ERECTYP=] [,TRACECH=];


A30808-X3247-M230-6-7619

453
CML:BSC CTRSCHED
Id:0900d805800d4225
Long Names:
NAME Addres of the managed object
CID cellIdentity
MACONN maxConnectionNumber
START startDate
STOP stopDate
PERWEEK periodWeekly
TRACERECTYP traceRecordType
TRACECH tracedChannel
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
The STOP attribute must be set at a value greater or equal to the value of START.
Example of Command Execution:
Set CTRSCHED:NAME=CTRCO:0/CTR-
SCHED:0,CID=BTSM:2/BTS:2,MACONN=128,
START=2-2-1995,STOP=31-12-2099,PERWEEK=all(0),TRACERECTYP=Mes-
sage,TRACECH=SDCCH;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The attribute CID must refer to an equipped cell.
UNSUCCESSFUL_TOO_MANY_TRACES
The command is rejected if the maximum number of con-
nections traceable in a BSS, considering all the scheduled
periods, would be exceeded
UNSUCCESSFUL_CELL_ALREADY_TRACED
In the same cell there must be no overlapping periods.
INVALID_COMMAND
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance
is in LOCKED state.


454 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4225
CTRSCHED
UNLOCK CTRSCHED
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL CTRCO CTRSCHED UNLOCK
CTRSCHED
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock CTRSCHED:NAME=CTRCO:0/CTRSCHED:3;
UNLOCK CTRSCHED NAME=CTRCO:0..0/CTRSCHED:0..31;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


A30808-X3247-M230-6-7619

455
CML:BSC DISK
Id:0900d805800d422b
DISK
The DISK object represents the mass memory storage of the BSS.
FORMAT DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK FORMAT DISK
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command lets the user to format one or both disk copies.
Long Names:
NAME Addres of the managed object
DISKCOPY diskCopy
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. In case of DISKCOPY=BOTH_DISK, the command formats all disk copies having
the following characteristics:
the administrative state LOCKED.
the superordinate state UNLOCKED and ENABLED.
2. No matter the operative state of the disk (ENABLED or DISABLED) is, it will be
turned to DISABLED as soon as the command is submitted. At the command
execution end, the disk successfully formatted will turn to ENABLED state.
3. In case of DISKCOPY=SELECTED (0 or 1),the disk copy administrative state must
be set to LOCKED by the user (see LOCK command), otherwise the command is
rejected (invalid administrative state).
DISKCOPY=BOTH_DISK can be selected only if both disks are present and in
service.
FORMAT DISK NAME=DISK:0..1 [,DISKCOPY=];
ADMINISTRATIVE_STATE_INVALID
ALREADY_IN_TARGET_STATE


456 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422b
DISK
4. If the format operation is successful, the disk administrative state must be reset to
UNLOCKED by the user (see UNLOCK command).
5. A Disk Copy Format (which takes about 15 seconds) causes a total loss of its
content.
6. The other File System commands cannot be executed during a format command;
they will be performed at the end of the format command.
Example of Command Execution:
Format DISK:NAME=DISK:0,DISKCOPY=SELECTED;
GET DISK STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK GET DISK STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
DISK object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET DISK STAT NAME=DISK:0..1;


A30808-X3247-M230-6-7619

457
CML:BSC DISK
Id:0900d805800d422b
Example of Command Execution:
Get DISK STAT:NAME=DISK:0;
GETRELATIONSHIP DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK GETRELATIONSHIP
DISK
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.

The DISK object does not have associated FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship DISK:NAME=DISK:0;
GETRELATIONSHIP
DISK
NAME=DISK:0..1;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object does not provide any relationship attribute.


458 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422b
DISK
GETSUBO DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK GETSUBO DISK
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more packs with a maximum
number of ten subordinated mnemonics; at the end a message is displayed notifying the
end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo DISK:NAME=DISK:0;
GETTEST DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK GETTEST DISK
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
GETSUBO DISK NAME=DISK:0..1;
GETTEST DISK NAME=DISK:0..1;


A30808-X3247-M230-6-7619

459
CML:BSC DISK
Id:0900d805800d422b
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest DISK:NAME=DISK:0;
LOCK DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK LOCK DISK
GETTEST DISK:NAME=DISK:0;
name = TEST:<n>
mOts = DISK:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
LOCK DISK NAME=DISK:0..1;


460 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422b
DISK
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock DISK:NAME=DISK:0;
PERFTEST DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK PERFTEST DISK
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected DISK object; the test consists
of the following phases:
Preliminary Test (start phase),
Accessibility Test (WP1),
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
PERFTEST DISK NAME=DISK:0..1;


A30808-X3247-M230-6-7619

461
CML:BSC DISK
Id:0900d805800d422b
Autodiagnostic Test (WP2),
Remote Accessibility (WP3),
Remote Autodiagnostic (WP4),
File System Check (WP5),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST DISK:NAME=DISK:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....


462 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422b
DISK
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the LOCKED
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest DISK:NAME=DISK:0;
STOPTEST DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK STOPTEST DISK
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
MOTS_NOT_LOCKED
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
STOPTEST DISK NAME=DISK:0..1;


A30808-X3247-M230-6-7619

463
CML:BSC DISK
Id:0900d805800d422b
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
STOPTEST DISK:NAME=DISK:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = DISK:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.


464 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422b
DISK
Example of Command Execution:
Stoptest DISK:NAME=DISK:0;
UNLOCK DISK
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DISK UNLOCK DISK
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the DISK card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock DISK:NAME=DISK:0;
UNLOCK DISK NAME=DISK:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


A30808-X3247-M230-6-7619

465
CML:BSC DK40
Id:0900d805800d422f
DK40
The DK40 object executes File System functions and monitoring of the alarm and fuse
panel of the system.
GET DK40 STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GET DK40 STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
DK40 object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get DK40 STAT:NAME=DK40:0;
GET DK40 STAT NAME=DK40:0..0;


466 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422f
DK40
GETRELATIONSHIP DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GETRELATIONSHIP
DK40
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.

The DK40 object doesn't have associated FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship DK40:NAME=DK40:0;
GETSUBO DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GETSUBO DK40
GETRELATIONSHIP
DK40
NAME=DK40:0..0;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object does not provide any relationship attribute.
GETSUBO DK40 NAME=DK40:0..0;


A30808-X3247-M230-6-7619

467
CML:BSC DK40
Id:0900d805800d422f
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo DK40:NAME=DK40:0;
GETTEST DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 GETTEST DK40
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
GETTEST DK40 NAME=DK40:0..0;


468 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422f
DK40
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest DK40:NAME=DK40:0;
LOCK DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 LOCK DK40
Applicability:
Phase 2.
Visibility level: 1.
GETTEST DK40:NAME=DK40:0;
name = TEST:<n>
mOts = DK40:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
LOCK DK40 NAME=DK40:0..0;


A30808-X3247-M230-6-7619

469
CML:BSC DK40
Id:0900d805800d422f
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
3. If DK40 will be locked when a cross copy procedure is in progress the cross copy
stops and it does not restart when DK40 is unlocked again. The diagnostic on DK40
must be required in order to restart the cross copy procedure.
Example of Command Execution:
Lock DK40:NAME=DK40:0;
PERFTEST DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 PERFTEST DK40
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected DK40 object; the test consists
of the following phases:
Accessibility Test (start phase),
Forced Alarm Test (WP1),
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
PERFTEST DK40 NAME=DK40:0..0;


470 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422f
DK40
DUAM Test (WP2),
FW RAM/DPR/SCC Tests (WP3),
FW Hard Disk Test (WP4),
Alarm Panel Test (WP5),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST DISK:NAME=DK40:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase; addi-
tional information is provided for each phase.
phaseId =
....


A30808-X3247-M230-6-7619

471
CML:BSC DK40
Id:0900d805800d422f
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest DK40:NAME=DK40:0;
STOPTEST DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 STOPTEST DK40
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
MOTS_NOT_LOCKED
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
STOPTEST DK40 NAME=DK40:0..0;


472 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d422f
DK40
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
STOPTEST DISK:NAME=DK40:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = DK40:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.


A30808-X3247-M230-6-7619

473
CML:BSC DK40
Id:0900d805800d422f
Example of Command Execution:
Stoptest DK40:NAME=DK40:0;
UNLOCK DK40
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE DK40 UNLOCK DK40
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the DK40 card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock DK40:NAME=DK40:0;
UNLOCK DK40 NAME=DK40:0..0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.


474 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4232
ENVA
ENVA
The ENVA (Environmental Alarms) object is used to manage the enviromental alarms
of the BSC.
CREATE ENVA
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA CREATE ENVA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a sense point for the alarm detection in the BSC.
Long Names:
NAME Addres of the managed object
ENVANAME envaName
INTINF interfaceInformation
THR threshold
ASEV associatedSeverity
ASTRING associatedString
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
In case the alarm absence is detected (with detection interval of one second) for a
number of consecutive times equal to the triple of the threshold attribute, the end alarm
condition is notified by means of a Failure Event Report with CLEARED severity.
CREATE ENVA NAME=ENVA:0..20 ,ENVANAME= [,INTINF=] [,THR=]
[,ASEV=] [,ASTRING=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
ENVA instances greater than 4 are allowed only with the
network card NTWSNAP_STLP.


A30808-X3247-M230-6-7619

475
CML:BSC ENVA
Id:0900d805800d4232
Example of Command Execution:
Create ENVA:NAME=ENVA:0,ENVANAME=TEMPERATURE,INTINF=low,
THR=30,ASEV=CRITICAL,ASTRING="High_Temperature";
DELETE ENVA
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA DELETE ENVA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a configurated sense point for the alarm detection in the BSC.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete ENVA:NAME=ENVA:0;
GET ENVA
DELETE ENVA NAME=ENVA:0..20;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting an ENVA, the relative object instance
must be in LOCKED state.
GET ENVA NAME=ENVA:0..20 [,REQATTL= ENVANAME ,INTINF
,THR ,ASEV ,ASTRING];


476 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4232
ENVA
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA GET ENVA
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the ENVA object.
Long Names:
NAME Addres of the managed object
ENVANAME envaName
INTINF interfaceInformation
THR threshold
ASEV associatedSeverity
ASTRING associatedString
System Responses:
- Operation Completed
GET ENVA BASICS
- Operation Failed
NACK CAUSES:
ENVAN-
AME:
envaName
INTINF: interfaceInformation
THR: threshold
ASEV: associatedSeverity
ASTRING: associatedString
ENVAN-
AME:
envaName
INTINF: interfaceInformation
THR: threshold
ASEV: associatedSeverity
ASTRING: associatedString
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

477
CML:BSC ENVA
Id:0900d805800d4232
Application Guidelines:
None.
GET ENVA BASICS
None.
Example of Command Execution:
Get ENVA:NAME=ENVA:0,REQATTL=ENVANAME&INTINF&THR&ASEV&ASTRING;
GET ENVA BASICS
Get ENVA BASICS:NAME=ENVA:0;
GET ENVA BASICS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA GET ENVA BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the ENVA object.
Long Names:
NAME Addres of the managed object
ENVANAME envaName
INTINF interfaceInformation
THR threshold
ASEV associatedSeverity
ASTRING associatedString
System Responses:
See GET ENVA
Application Guidelines:
See GET ENVA
Example of Command Execution:
See GET ENVA
GET ENVA BASICS NAME=ENVA:0..20;


478 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4232
ENVA
GET ENVA STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA GET ENVA STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
ENVA object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get ENVA STAT:NAME=ENVA:0;
LOCK ENVA
GET ENVA STAT NAME=ENVA:0..20;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK ENVA NAME=ENVA:0..20;


A30808-X3247-M230-6-7619

479
CML:BSC ENVA
Id:0900d805800d4232
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA LOCK ENVA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command will stop the ENVA alarms until next UNLOCK command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock ENVA:NAME=ENVA:0;
SET ENVA
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA SET ENVA
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET ENVA NAME=ENVA:0..20 [,ENVANAME=] [,INTINF=] [,THR=]
[,ASEV=] [,ASTRING=];


480 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4232
ENVA
Command Description:
This command modifies the sense point configuration for the alarm detection in the BSC.
Long Names:
NAME Addres of the managed object
ENVANAME envaName
INTINF interfaceInformation
THR threshold
ASEV associatedSeverity
ASTRING associatedString
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set ENVA:NAME=ENVA:0,ENVANAME=TEMPERATURE,INTINF=low,THR=28,
ASEV=MAJOR,ASTRING="Temperature";
UNLOCK ENVA
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ENVA UNLOCK ENVA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNLOCK ENVA NAME=ENVA:0..20;


A30808-X3247-M230-6-7619

481
CML:BSC ENVA
Id:0900d805800d4232
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock ENVA:NAME=ENVA:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


482 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4237
EPWR
EPWR
The EPWR object represents the extended frame power distributor that provides power
supply to the LICD and PPXX boards configured in the extended module of the BSC.
CREATE EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR CREATE EPWR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds an additional Power Supply (EPWR) to the system. This is required
to support expansions to the Base Configuration.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. Before submitting the command, the relevant hardware has to be plugged in proper
slot.
2. After the creation of the object, the ADMINISTRATIVE state of this object is set to
UNLOCKED. The UNLOCK command is NOT required to put this object in service.
3. It should be avoided to create and equipped only one EPWR.
Example of Command Execution:
Create EPWR:NAME=EPWR:0;
CREATE EPWR NAME=EPWR:0..1;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order
to perform the command.
UNSUCCESSFUL_COMMAND_REJECTED
No EPWR instance can be created if the network card is
NTWSNAP_STLP.


A30808-X3247-M230-6-7619

483
CML:BSC EPWR
Id:0900d805800d4237
DELETE EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR DELETE EPWR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the additional Power Supply (EPWR) previously created through
the CREATE EPWR command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
The relevant hardware can be unplugged after submitting the command.
Example of Command Execution:
Delete EPWR:NAME=EPWR:0;
DELETE EPWR NAME=EPWR:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
Before deleting the last EPWR object instance all the instances of
the LICD/PPXU objects, related to the extended module of the
BSC, must be deleted.
In order to delete the last EPWR no PCUs must be equipped.
UNSUCCESSFUL_INVALID_STATUS
The object has to be previously set at the LOCKED state through
the LOCK command. Furthermore its state must be DISABLED and
to achieve this the concerned REQ_SWITCH at EPWR rack must
be set at OFF.
UNSUCCESSFUL_IN_TEST
A diagnostic test is running on the relevant hardware.


484 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4237
EPWR
GET EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GET EPWR
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the EQUIPPED status of the additional Power Supply
(EPWR) previously created through the CREATE EPWR command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get EPWR:NAME=EPWR:0;
GET EPWR STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GET EPWR STAT
Applicability:
Phase 2.
Visibility level: 0.
GET EPWR NAME=EPWR:0..1;
NAME: name
NOT_EQUIPPED
The object instance must be already equipped.
GET EPWR STAT NAME=EPWR:0..1;


A30808-X3247-M230-6-7619

485
CML:BSC EPWR
Id:0900d805800d4237
Command Description:
This command is used to retrieve the following State/Status attributes related to the
EPWR object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get EPWR STAT:NAME=EPWR:0;
GETSUBO EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GETSUBO EPWR
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETSUBO EPWR NAME=EPWR:0..1;


486 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4237
EPWR
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed
notifying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo EPWR:NAME=EPWR:0;
GETTEST EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR GETTEST EPWR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETTEST EPWR NAME=EPWR:0..1;
GETTEST EPWR:NAME=EPWR:0;
name = TEST:<n>
mOts = EPWR:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.


A30808-X3247-M230-6-7619

487
CML:BSC EPWR
Id:0900d805800d4237
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest EPWR:NAME=EPWR:0;
LOCK EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR LOCK EPWR
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK EPWR NAME=EPWR:0..1;


488 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4237
EPWR
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock EPWR:NAME=EPWR:0;
PERFTEST EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR PERFTEST EPWR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected EPWR object; the test consists
of the following phases:
Accessibility Test (start phase),
Basic Maintenance Test (WP1),
Full Maintenance Test (WP2),
End Test (end phase).
Long Names:
NAME Addres of the managed object
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PERFTEST EPWR NAME=EPWR:0..1;


A30808-X3247-M230-6-7619

489
CML:BSC EPWR
Id:0900d805800d4237
System Responses:
- Operation Completed
- Operation Failed
PERFTEST EPWR:NAME=EPWR:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase. phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)


490 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4237
EPWR
NACK CAUSES:
Application Guidelines:
1. The test can be executed with the object in "Unlocked" administrative state.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest EPWR:NAME=EPWR:0;
STOPTEST EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR STOPTEST EPWR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
STOPTEST EPWR NAME=EPWR:0..1;


A30808-X3247-M230-6-7619

491
CML:BSC EPWR
Id:0900d805800d4237
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STOPTEST EPWR:NAME=EPWR:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = EPWR:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


492 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4237
EPWR
Application Guidelines:
None.
Example of Command Execution:
Stoptest EPWR:NAME=EPWR:0;
UNLOCK EPWR
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE EPWR UNLOCK EPWR
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the EPWR card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock EPWR:NAME=EPWR:0;
UNLOCK EPWR NAME=EPWR:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

493
CML:BSC ES
Id:0900d805800d5603
ES
The ES object represents the Ethernet switching network functionality that handles the
High Speed Gb interface.
GET ES STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES GET ES STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the ES
object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get ES STAT:NAME=ES:0;
GET ES STAT NAME=ES:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


494 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
GETINFO ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES GETINFO ES
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the ES: AST, OST, AVS, CST.
2. The FW version present on board.
3. The Board Edition.
4. Information concerning each fast and giga Ethernet port (note: the ports no. 0 -19 are
fast Ethernet ports; the ports no. 20 and 21 correspond to the giga ports 0 and 1):
- flag indicating if port is enabled or closed (Boolean)
- physical layer availability (Boolean)
- the MAC address (Medium Access Control) detected on port (note: if more than one
MAC address have been detected, only the firts one of the MAC table list will be dis-
played).
- instance of PPXU connected to this port (0..11)
- duplex mode (possible values: HALF_DUPLEX (0), FULL_DUPLEX (1))
- actual speed (possible values: BASE_T_10 (0), BASE_T_100 (1), BASE_T_1000(2))
- flag indicating if auto-negotiation error is present (Boolean)
- flag indicating if auto-negotiation is in progress (Boolean)
- flag indicating if auto-negotiation is supported by peer (Boolean)
- flag indicating if jumbo frames are enabled (Boolean)
- flag indicating if port buffer is full (Boolean)
- flag indicating if internal fatal error is present (Boolean)
- number of received packets with CRC errors (integer of 4 bytes)
- flag indicating if local receiver failure is present (Boolean) (a)
- flag indicating if remote link failure is present (Boolean) (a)
( I ) NOTE:
- all fields relevant to Ethernet ports are optional
- all PPXU is considered connected to the ES only if it is connected to a fast port (0..19)
and the PPXU port number is the same as ES instance (i.e. PPXU port 0 with ES 0). In
GETINFO ES NAME=ES:0..1;


A30808-X3247-M230-6-7619

495
CML:BSC ES
Id:0900d805800d5603
case of wrong connection (i.e. PPXU port 0 with ES 1, or PPXU connected to a giga port)
no PPXU connection shall be dislayed on the port.
- the fields (a) are available only for giga ports, and only when the actual speed is 1000
BT (see IEEE Std. 802.3-2002 par. 40.2.8, 40.2.9).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO ES ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT ES:
NAME = ES:0
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PROCEDURAL STATUS: NONE
CONTROL STATUS: NONE
FW VERSION: sfa3100
BOARD EDITION: 5
PORT 0:
PORT ENABLED: TRUE
PHYSICAL LAYER AVAILABLE: TRUE
DETECTED MAC: 12:34:56:78:9A:01
PPXU INSTANCE: 3
DUPLEX MODE: FULL_DUPLEX
SPEED: BASE_T_100
AUTONEGOTIATION ERROR: FALSE
AUTONEGOTIATION IN PROGRESS: FALSE
AUTONEGOTIATION SUPPORTED BY PEER: TRUE
JUMBO FRAME ENABLED: TRUE
PORT BUFFER FULL: FALSE
PORT INTERNAL FATAL ERROR: FALSE
NUMBER OF CRC ERRORS: 95398


496 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
PORT 1:
PORT ENABLED: TRUE
PHYSICAL LAYER AVAILABLE: FALSE
DETECTED MAC: 00:43:00:34:00:00
PORT 2:
PORT ENABLED: FALSE
PHYSICAL LAYER AVAILABLE: FALSE
... ... ...
PORT 19:
PORT ENABLED: TRUE
PHYSICAL LAYER AVAILABLE: TRUE
DETECTED MAC: 12:34:56:78:9A:01
PPXU INSTANCE: 7
DUPLEX MODE: HALF_DUPLEX
SPEED: BASE_T_100
AUTONEGOTIATION ERROR: FALSE
AUTONEGOTIATION IN PROGRESS: FALSE
AUTONEGOTIATION SUPPORTED BY PEER: TRUE
JUMBO FRAME ENABLED: TRUE
PORT BUFFER FULL: FALSE
PORT INTERNAL FATAL ERROR: TRUE
NUMBER OF CRC ERRORS: 565
PORT 20:
PORT ENABLED: TRUE
PHYSICAL LAYER AVAILABLE: TRUE
DETECTED MAC: 12:34:56:78:9A:01
DUPLEX MODE: FULL_DUPLEX
SPEED: BASE_T_100
AUTONEGOTIATION ERROR: FALSE
AUTONEGOTIATION IN PROGRESS: FALSE
AUTONEGOTIATION SUPPORTED BY PEER: TRUE
JUMBO FRAME ENABLED: TRUE
PORT BUFFER FULL: FALSE
PORT INTERNAL FATAL ERROR: FALSE
NUMBER OF CRC ERRORS: 5432


A30808-X3247-M230-6-7619

497
CML:BSC ES
Id:0900d805800d5603
LOCAL RECEIVER FAILURE: FALSE
REMOTE LINK FAILURE: FALSE
PORT 21:
PORT ENABLED: TRUE
PHYSICAL LAYER AVAILABLE: TRUE
DETECTED MAC: 12:34:56:78:9A:01
DUPLEX MODE: FULL_DUPLEX
SPEED: BASE_T_100
AUTONEGOTIATION ERROR: FALSE
AUTONEGOTIATION IN PROGRESS: FALSE
AUTONEGOTIATION SUPPORTED BY PEER: TRUE
JUMBO FRAME ENABLED: TRUE
PORT BUFFER FULL: FALSE
PORT INTERNAL FATAL ERROR: FALSE
NUMBER OF CRC ERRORS: 5
LOCAL RECEIVER FAILURE: FALSE
REMOTE LINK FAILURE: FALSE
END OF REPORT
- Operation Failed
*** RESPONSE TO JOB 1***
Get Info Report Nack ES:
name = ES:0
nackCause = <nack cause>
Application Guidelines:
None
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


498 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
Example of Command Execution:
Getinfo ES:NAME=ES:0;
GETRELATIONSHIP ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES GETRELATIONSHIP ES
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the NSVLIP object the related HMOs are the following: GBIPLNK, NSVLIP.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
Example of Command Execution:
Getrelationship ES:NAME=ES:0;
GETRELATIONSHIP
ES
NAME=ES:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

499
CML:BSC ES
Id:0900d805800d5603
GETSUBO ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES GETSUBO ES
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed
notifying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo ES:NAME=ES:0;
GETTEST ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES GETTEST ES
Applicability:
Phase 2.
Visibility level: 2.
GETSUBO ES NAME=ES:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETTEST ES NAME=ES:0..1;


500 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest ES:NAME=ES:0;
GETTEST EPWR:NAME=ES:0;
name = TEST:<n>
mOts = ES:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


A30808-X3247-M230-6-7619

501
CML:BSC ES
Id:0900d805800d5603
LOCK ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES LOCK ES
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
The administrative state Locked will survive at the Full Init (and consequently to the load
database).
Example of Command Execution:
Lock ES:NAME=ES:0;
PERFTEST ES
LOCK ES NAME=ES:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state.
PERFTEST ES NAME=ES:0..1;


502 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES PERFTEST ES
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected ES object; the test consists of
the following phases:
Accessibility Test (start phase),
Basic Maintenance Test (WP1),
Full Maintenance Test (WP2),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST ES:NAME=ES:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases


A30808-X3247-M230-6-7619

503
CML:BSC ES
Id:0900d805800d5603
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The test can be executed with the object in "Unlocked" administrative state.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
3. During the execution of the command PERFTEST on the board ESAM, the system
verify the presence of a firmware file stored in the BSC disk and related to the board,
if a file is present it performs the verification of the loaded Firmware version towords
the Firmware file, if the version differs then it automatically proceeds to the updating.
The Firmware file must be stored in a dedicated directory structure created using
Creatdir commands and stored using using dnlFile commands.
Example of Command Execution:
Perftest ES:NAME=ES:0;
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


504 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
STOPTEST ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES STOPTEST ES
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
STOPTEST ES NAME=ES:0..1;
STOPTEST ES:NAME=ES:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = ES:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases


A30808-X3247-M230-6-7619

505
CML:BSC ES
Id:0900d805800d5603
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest ES:NAME=ES:0;
UNLOCK ES
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE ES UNLOCK ES
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
UNLOCK ES NAME=ES:0..1;


506 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5603
ES
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock ES:NAME=ES:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

507
CML:BSC FAN
Id:0900d805800d423e
FAN
The FAN object represents the complex of 6 fans contained in the box placed on top of
the BSC. The fans are present only in the new BSC rack.
GET FAN STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE FAN GET FAN STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the FAN
object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CST)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get FAN STAT:NAME=FAN:0;
GET FAN STAT NAME=FAN:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


508 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d423e
FAN
GETRELATIONSHIP FAN
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE FAN GETRELATIONSHIP
FAN
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship FAN:NAME=FAN:0;
GETSUBO FAN
GETRELATIONSHIP
FAN
NAME=FAN:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
GETSUBO FAN NAME=FAN:0..0;


A30808-X3247-M230-6-7619

509
CML:BSC FAN
Id:0900d805800d423e
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE FAN GETSUBO FAN
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo FAN:NAME=FAN:0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


510 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4241
FHSY
FHSY
FHSY logs all information related to the rules of the frequency hopping system for each
cell of the BSC.
CREATE FHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY CREATE
FHSY
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an hopping law. The frequency list (MOBALLOC) is composed
of the frequencies of the previously created TRX, in case of base band hopping and of
the frequencies previously assigned to BTS, excluding BCCH frequency, in case of syn-
thesizer hopping.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
MOBALLOC mobileAllocation
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
CREATE FHSY NAME=BTSM:0..199/BTS:0..23/FHSY:1..10 ,HSN=
,MOBALLOC=;
Successful
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTS object instance must already be equipped.
UNSUCCESSFUL_TRX_FREQ_NOT_FOUND
In case of base band frequency hopping, the frequencies speci-
fied in the MOBALLOC parameter do not belong to any instance
of TRXs already equipped.


A30808-X3247-M230-6-7619

511
CML:BSC FHSY
Id:0900d805800d4241
UNSUCCESSFUL_OVERLAP_BAND
If the cell which the FHSY belongs to is a EXT900 cell, the fre-
quencies contained in the MOBALLOC list have to be chosen to
avoid overlapping between the two bands of
frequencies (primary GSM and GSM extension).
If the cell which the FHSY belongs to is a GSMDCS cell, the fre-
quencies contained in the MOBALLOC list have to be chosen to
avoid overlapping between the three bands of
frequencies (primary GSM, GSM extension and DCS1800 band).
If the cell which the FHSY belongs to is a GSM850PCS cell, the
frequencies contained in the MOBALLOC list have to be chosen
to avoid overlapping between the two bands of frequencies
(GSM850 and PCS1900).
If the cell which the FHSY belong to is a GSM850PCS cell, the
frequencies contained in the MOBALLOC list have to be chosen
to avoid overlapping between the two bands of frequencies
(GSM850 and PCS1900).
If the cell which the FHSY belongs to is a GSM850DCS cell, the
frequencies contained in the MOBALLOC list have to be chosen
to avoid overlapping between the two bands of frequencies
(GSM850 and DCS1800).
UNSUCCESSFUL_EQUAL_FREQ
In the MOBALLOC attribute cannot be set a CALLF<nn> field
more than one time.
UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL
In case of synthesized frequency hopping, the frequencies spec-
ified in the "mobile allocation" parameter must belong to the fre-
quency assigned to the cell.
FREQUENCY_NOT_ALLOWED
In case of synthesizer frequency hopping, the BCCH frequency
of the cell (BCCHFREQ attribute of the BTS object) cannot be
included in the "mobile allocation".
HSCSD_HOPP_INCONSISTENT
In a cell with Base Band Hopping Mode with HSCSD service acti-
vated, the MOBALLOC cannot contain the BCCH frequency if the
LY_00 is associated to HSCSDLLPRM, HSCSDLLCOM and one
or more CCCHs have already been equipped.
GPRS_HOPP_INCONSISTENT


512 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4241
FHSY
Application Guidelines:
None.
Example of Command Execution:
Create FHSY:NAME=BTSM:0/BTS:0/FHSY:1,HSN=2,MOBALLOC=CALLF01;
DELETE FHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY DELETE
FHSY
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an hopping law.
In a cell with Base Band Hopping Mode with GPRS service acti-
vated, the MOBALLOC cannot contain the BCCH frequency if the
LY_00 is associated to GLLPRM, GLLCOM and one or more
CCCHs have already been equipped.
In a cell with Base Band Hopping Mode if the DTMSUP flag is set
to TRUE in the PTPPKF object, the MOBALLOC cannot contain
the BCCH frequency if the LY 00 is associated to GLLPRM,
GLLCOM and one or more CCCHs have already been equipped.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
One ore more variables have been incorrectly set.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
All the TRXs belonging to the hopping law must have the same
TRXMODE (mixed configuration EDGE/GSM is not allowed).
If the cell supports EDGE the following conditions cannot be sat-
isfied at the same time: HoppingMode is Base Band, the BCCH
frequency belongs to the hopping law you are creating (and the
BCCH TRX has TRXMD=EDGE), and the EBCCHTRX attribute
of the PTPPKF object is set to FALSE.
EDGE_HOPP_INCONSISTENT
In a cell with Base Band Hopping Mode with EDGE service acti-
vated, the MOBALLOC cannot contain the BCCH frequency if the
LY_00 is associated to ELLPRM, ELLCOM and one or more
CCCHs have already been equipped.
DELETE FHSY NAME=BTSM:0..199/BTS:0..23/FHSY:1..10;


A30808-X3247-M230-6-7619

513
CML:BSC FHSY
Id:0900d805800d4241
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete FHSY:NAME=BTSM:0/BTS:0/FHSY:1;
GET FHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY GET FHSY
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the value of the parameters selected by the operator
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
MOBALLOC mobileAllocation
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The FHSY instance must not be pointed by any CHAN
instance, otherwise the DELETE command is rejected.
GET FHSY NAME=BTSM:0..199/BTS:0..23/FHSY:1..10 [,REQATTL=
HSN ,MOBALLOC];


514 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4241
FHSY
System Responses:
- Operation Completed
GET FHSY BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET FHSY BASICS
None.
Example of Command Execution:
Get FHSY:NAME=BTSM:0/BTS:0/FHSY:1,REQATTL=HSN&MOBALLOC&;
GET FHSY BASICS
Get FHSY BASICS:NAME=BTSM:0/BTS:0/FHSY:1;
GET FHSY BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY GET FHSY
BASICS
Applicability:
Phase 2.
Visibility level: 0.
NAME:name
HSN:hoppingSequenceNumber
MOBALLOC:mobileAllocation
NAME:name
HSN:hoppingSequenceNumber
MOBALLOC:mobileAllocation
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET FHSY BASICS NAME=BTSM:0..199/BTS:0..23/FHSY:1..10;


A30808-X3247-M230-6-7619

515
CML:BSC FHSY
Id:0900d805800d4241
Command Description:
This command is used to retrieve the value of the parameters selected by the operator
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
MOBALLOC mobileAllocation
System Responses:
See GET FHSY
Application Guidelines:
See GET FHSY
Example of Command Execution:
See GET FHSY
SET FHSY
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS FHSY SET FHSY
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies an hopping law.
Long Names:
NAME Addres of the managed object
HSN hoppingSequenceNumber
MOBALLOC mobileAllocation
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
SET FHSY NAME=BTSM:0..199/BTS:0..23/FHSY:1..10 [,HSN=]
[,MOBALLOC=];
Successful
UNSUCCESSFUL_SUBORDINATE_EQUIPPED


516 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4241
FHSY
The FHSY instance must not be pointed by any CHAN instance,
otherwise the MOBALLOC parameter can not be set.
UNSUCCESSFUL_TRX_FREQ_NOT_FOUND
In case of base band frequency hopping, the frequencies specified
in the MOBALLOC parameter must belong to an instance of TRX
already equipped.
UNSUCCESSFUL_OVERLAP_BAND
If the cell which the FHSY belongs to is a EXT900 cell, the
frequencies contained in the MOBALLOC list have to be chosen
to avoid overlapping between the two bands of frequencies
(primary GSM and GSM extension).
If the cell which the FHSY belongs to is a GSMDCS cell, the fre-
quencies contained in the MOBALLOC list have to be chosen to
avoid overlapping between the three bands of frequencies
(primary GSM, GSM extension and DCS1800 band).
If the cell which the FHSY belongs to is a GSM850PCS cell, the
frequencies contained in the MOBALLOC list have to be chosen
to avoid overlapping between the two bands of frequencies
(GSM850 and PCS1900).
If the cell which the FHSY belongs to is a GSM850DCS cell, the
frequencies contained in the MOBALLOC list have to be chosen
to avoid overlapping between the two bands of frequencies
(GSM850 and DCS1800).
UNSUCCESSFUL_EQUAL_FREQ
In the MOBALLOC attribute a CALLF<nn> field can not be set
more than once.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_STATUS
In order to change the HSN attribute the BTS must be in LOCKED
state and no CHAN instance must point to the FHSY instance.
UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL
In case of synthesized frequency hopping, the frequencies speci-
fied in the MOBALLOC parameter must belong to the frequency
assigned to the cell.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
One ore more variables have been incorrectly set.
FREQUENCY_NOT_ALLOWED
In case of synthesizer frequency hopping, the BCCH frequency of
the cell (BCCHFREQ attribute of the BTS object) cannot be
included in the "mobile allocation".


A30808-X3247-M230-6-7619

517
CML:BSC FHSY
Id:0900d805800d4241
Application Guidelines:
None
Example of Command Execution:
Set FHSY:NAME=BTSM:0/BTS:0/FHSY:1,HSN=3,MOBALLOC=CALLF02;
HSCSD_HOPP_INCONSISTENT
In a cell with Base Band Hopping Mode with HSCSD service acti-
vated, the MOBALLOC cannot contain the BCCH frequency if the
LY_00 is associated to HSCSDLLPRM, HSCSDLLCOM and one
or more CCCHs have already been equipped.
GPRS_HOPP_INCONSISTENT
In a cell with Base Band Hopping Mode with GPRS service acti-
vated, the MOBALLOC cannot contain the BCCH frequency if the
LY_00 is associated to GLLPRM, GLLCOM and one or more
CCCHs have already been equipped.
In a cell with Base Band Hopping Mode if the DTMSUP flag is set
to TRUE in the PTPPKF object, the MOBALLOC cannot contain
the BCCH frequency if the LY 00 is associated to GLLPRM,
GLLCOM and one or more CCCHs have already been equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
All the TRXs belonging to the hopping law must have the same
TRXMODE (mixed configuration EDGE/GSM is not allowed).
If the cell supports EDGE the following conditions cannot be satis-
fied at the same time: HoppingMode is Base Band, the BCCH fre-
quency belongs to the hopping law you are creating (and the
BCCH TRX has TRXMD=EDGE), and the EBCCHTRX attribute of
the PTPPKF object is set to FALSE.
EDGE_HOPP_INCONSISTENT
In a cell with Base Band Hopping Mode with EDGE service acti-
vated, the MOBALLOC cannot contain the BCCH frequency if the
LY_00 is associated to ELLPRM, ELLCOM and one or more
CCCHs have already been equipped.


518 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4244
FILEHANDLER
FILEHANDLER
The FILEHANDELR object allows to handle files on BSC disks.
Only 1 instance is allowed for this object.
COPY FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER COPY
FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs a copy of a software or database file on BSC disk.
Long Names:
NAME Addres of the managed object
SRCPATHNAME sourcePathName
DESTPATHNAME destinationPathName
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
COPY FILEHANDLER NAME=FILEHANDLER:0..0 ,SRCPATHNAME= ,DEST-
PATHNAME=;
NAME: name
SRCPATHNAME: sourcePathName
DESTPATHNAME: destinationPathName
FILE_PRESENT
The file is already present.
NO_ADMITTED_OPERATION
The file to be copied is a directory.
FILE_NOT_FOUND
The file to be copied is not found.
FS_FAILED


A30808-X3247-M230-6-7619

519
CML:BSC FILEHANDLER
Id:0900d805800d4244
Application Guidelines:
This command can be performed if a software or database file is present on BSC disk
and it is used for recovery actions only.
Example of Command Execution:
Copy FILEHANDLER:NAME=FILEHANDLER:0,SRCPATHNAME="Source_dir",
DESTPATHNAME="Dest_dir";
CREATEDIR FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER CREATE-
DIR FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs a creation of a disk directory.
Long Names:
NAME Addres of the managed object
DIRNAME directoryName
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
A generic file system is occurred.
NOT_SYSTEM_RESOURCE
The memory to be allocated is not enough.
CREATEDIR FILEHAN-
DLER
NAME=FILEHANDLER:0..0 ,DIRNAME=;
NAME: name
DIRNAME: directoryName
FILE_PRESENT
The file already exists.
FS_FAILED
A generic file system error has occurred.


520 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4244
FILEHANDLER
Application Guidelines:
This command must be used for recovery actions only.
Example of Command Execution:
Createdir FILEHANDLER:NAME=FILEHANDLER:0,DIRNAME="Dir_Name";
DELETE FILEHANDLER GENFILE
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER DELETE
FILEHANDLER GENFILE
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs a deletion of a generic file.
Long Names:
NAME Addres of the managed object
PATHNAME pathName
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
This command can be performed if a software or database file is present on BSC disk
and it is used for recovery actions only.
Example of Command Execution:
Delete FILEHANDLER GENFILE:NAME=FILEHANDLER:0,
DELETE FILEHAN-
DLER GENFILE
NAME=FILEHANDLER:0..0 ,PATHNAME=;
NAME: name
PATHNAME: pathName
FILE_NOT_FOUND
The file to be deleted is not found.
FS_FAILED
A generic file system error has occurred.


A30808-X3247-M230-6-7619

521
CML:BSC FILEHANDLER
Id:0900d805800d4244
PATHNAME="Path_name";
DIR FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER DIR FILE-
HANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command displays contents of the referenced BSC disk directory.
Long Names:
NAME Addres of the managed object
DIRNAME directoryName
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Dir FILEHANDLER:NAME=FILEHANDLER:0,DIRNAME="Dir_Name";
DIR FILEHANDLER NAME=FILEHANDLER:0..0 ,DIRNAME=;
NAME: name
DIRNAME: directoryName
LFID: listOfFileIds
DISK0: disk-0
DISK1: disk-1
TOTNF: totalNumberOfFiles
DIRECTORY_NOT_FOUND
The directory to be displayed is not found.
FS_FAILED
A generic file system error has occurred.


522 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4244
FILEHANDLER
FILECOM FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER FILECOM
FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs compression procedure of a generic file.
Long Names:
NAME Addres of the managed object
TARGDIR targetDirectory
TARGF targetFile
DELOPT deleteOption
SRCDIR sourceDir
LFID listOfFileIds
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
This command is performed if the specific generic file is present on BSC disk and it must
be used for recovery actions only.
Example of Command Execution:
Filecom FILEHANDLER:NAME=FILEHANDLER:0,TARGDIR="Target_dir",
TARGF="File_name",DELOPT=TRUE,SRCDIR="Source_dir",
LFID="F_1"&"F_2"&"F_3"
FILECOM FILEHAN-
DLER
NAME=FILEHANDLER:0..0 ,TARGDIR= ,TARGF=
,DELOPT= ,SRCDIR= ,LFID=;
NAME: name
ABORT_BY_SYSTEM_NCK
FILE_NOT_FOUND
T_FILE_SYSTEM_ERROR


A30808-X3247-M230-6-7619

523
CML:BSC FILEHANDLER
Id:0900d805800d4244
FILEDECOM FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER FILEDE-
COM FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs a decompression procedure of a generic file.
Long Names:
NAME Addres of the managed object
TARGDIR targetDirectory
SRCDIR sourceDir
SRCFILE sourceFile
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
This command is performed if the specific generic file is present on BSC disk and it must
be used for recovery actions only.
Example of Command Execution:
Filedecom FILEHANDLER:NAME=FILEHANDLER:0,TARGDIR="Target_dir",
SRCDIR="Source_dir",SRCFILE="File_name";
MOVE FILEHANDLER
FILEDECOM FILEHAN-
DLER
NAME=FILEHANDLER:0..0 ,TARGDIR= ,SRCDIR= ,SRC-
FILE=;
NAME: name
ABORT_BY_SYSTEM_NCK
FILE_NOT_FOUND
MOVE FILEHANDLER NAME=FILEHANDLER:0..0 ,SRCPATHNAME= ,DEST-
PATHNAME=;


524 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4244
FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER MOVE
FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs moving of a software or database file present on BSC disk.
Long Names:
NAME Addres of the managed object
SRCPATHNAME sourcePathName
DESTPATHNAME destinationPathName
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. This command is performed if referenced file to move is present on BSC disk.
2. The command must be used for recovery actions only.
Example of Command Execution:
Move FILEHANDLER:NAME=FILEHANDLER:0,SRCPATHNAME="Source_path",
DESTPATHNAME="Dest_path";
NAME: name
SRCPATHNAME: sourcePathName
DESTPATHNAME: destinationPathName
FILE_PRESENT
The file is already present.
FILE_NOT_FOUND
The file to be moved is not found.
FS_FAILED
A generic file system is occurred.


A30808-X3247-M230-6-7619

525
CML:BSC FILEHANDLER
Id:0900d805800d4244
REMOVEDIR FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER
REMOVEDIR FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs a deletion of a referenced BSC disk directory.
Long Names:
NAME Addres of the managed object
DIRNAME directoryName
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. This command is performed if the specific generic directory is present on BSC disk.
2. The command must be used for recovery actions only.
Example of Command Execution:
Removedir FILEHANDLER:NAME=FILEHANDLER:0,DIRNAME="Directory";
REMOVEDIR FILEHAN-
DLER
NAME=FILEHANDLER:0..0 ,DIRNAME=;
NAME: name
PATHNAME: pathName
DIRECTORY_NOT_FOUND
The directory to be deleted is not found.
FS_FAILED
A generic file system is occurred.
DIRECTORY_NOT_EMPTY
The directory to be deleted is not empty.


526 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4244
FILEHANDLER
UPLPRLOG FILEHANDLER
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT FILEHANDLER
UPLPRLOG FILEHANDLER
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows to the user to upload the proprietary log files from the BSC disk
to a selected directory of the LMT.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
LOGTYPE Logtype
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
At the end of the upload procedure the local file indicated by means of DestinationDir
and DestinationFile will contain the requested logger. Any time an Upload operation is
requested for a proprietary log file a new file is created on the BSC disk in the LOG
directory. This file will be named either /LOG/LMT_CMD.UPL or /LOG/LMT_EVE.UPL
depending on the type of the proprietary log file requested (LOGTYPE).
Example of Command Execution:
Uplprlog FILEHANDLER:NAME=FILEHANDLER:0,DESTDIR="C:\Siemens",
OVERWRITE=YES,LOGTYPE=CMDRSPLOG;
UPLPRLOG FILEHAN-
DLER
NAME=FILEHANDLER:0..0 ,DESTDIR= ,OVERWRITE=
,LOGTYPE=;
NAME: name
FILE_NOT_FOUND
FS_FAILED


A30808-X3247-M230-6-7619

527
CML:BSC FRL
Id:0900d805800d46c1
FRL
The FRL functional object represents the physical link connection on Gb interface. The
connection can be realised via A interface (PCMA) or directly to SGSN via PCMG.
In case of A interface connection the 64 kbit/s time slots are reserved on PCMS and
handled in TRAU as transparent channels.
CREATE FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL CREATE FRL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the FRL object class. It can be done only if the
PCU and PCMA/PCMG are created. Creation of FRL link means to make a
semi-permanent network connection between the time slot on PCMA or PCMG and the
corresponding time slot on internal 2 Mbit/s. The availability of time slot on internal 2
Mbit/s must be checked using data assigned in PCU object and the space already allo-
cated to other FRL links.
The status at creation will be Locked-Disabled/Offline. When the BSC have been
aligned with the remote peer the FRL object will be put in "Enabled" state.
Long Names:
NAME Addres of the managed object
PCUID pcuIdentifier
GLK gprsLink
GTS gprsTimeSlot
T391 t391
N391 n391
N392 n392
N393 n393
TCONG timeCongestion
TCONOFF timeCongestionOff
FRSTD frameRelayStandard
System Responses:
- Operation Completed
CREATE FRL NAME=FRL:0..755 ,PCUID= ,GLK= ,GTS= [,T391=]
[,N391=] [,N392=] [,N393=] [,TCONG=] [,TCONOFF=]
[,FRSTD=];


528 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
( I ) The value of the timer T391 set on the BSC side must be lower than the value of the
timer T392 set either on the SGSN or the network side of the Frame Relay link.
Example of Command Execution:
Create
FRL:NAME=FRL:3,PCUID=PCU:0,GLK=PCMG:0,GTS=2&12,T391=10,N391=50,
N392=34,N393=10,TCONG=20,TCONOFF=25,FRSTD=ITU;
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
SUPERORDINATE_NOTEQUIPPED
The relevant PCU and PCMA/PCMG object instances must be
already equipped.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The timeslot inserted in the CREATE FRL command must be not
allocated by other links.
UNSUCCESSFUL_WRONG_ME_ID
The FRL can be connected only to a PCMA or a PCMG.
The operator cannot specify twice the same timeslot in the timeslot
list.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The attribute TCONOFF can assume one of the following values: 0,
10..30.
UNSUCCESSFUL_INVALID_STATUS
Before creating a FRL, the relative TRAU object instance must be
in LOCKED state.
UNSUCCESSFUL_INVALID_TIME_SLOT
The number of timeslots assigned to the FRL must be compatible
with the PCMTYPE attribute of the BSC object.
UNSUCCESSFUL_NOT_ENOUGH_INT_TSL
The maximum number of FRLs that can be assigned to a PCU is 63
if the network card is NTWSNAP or NTWSNAP_STLP.
UNSUCCESSFUL_INVALID_COMMAND
No FRL can be created if the superordinate PCU has the GBSNS
set to IPV4 value.


A30808-X3247-M230-6-7619

529
CML:BSC FRL
Id:0900d805800d46c1
DELETE FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL DELETE FRL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the FRL object class. It can be
done only if all NSVC, attached to considered FRL, are deleted and the deletion implies
the removing of the semi-permanent network connection. The object to be deleted shall
be previously locked.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete FRL:NAME=FRL:3;
DELETE FRL NAME=FRL:0..755;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a FRL, the relative object instance must be in
LOCKED state.
Before deleting a FRL, the relative TRAU object instance must be in
LOCKED state (if the FRL is attested on PCMA).
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
All the NSVC object instances associated to the FRL object instance
must be previously deleted.


530 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
GET FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL GET FRL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the FRL object
class.
Long Names:
NAME Addres of the managed object
PCUID pcuIdentifier
GLK gprsLink
GTS gprsTimeSlot
T391 t391
N391 n391
N392 n392
N393 n393
TCONG timeCongestion
TCONOFF timeCongestionOff
FRSTD frameRelayStandard
System Responses:
- Operation Completed
GET FRL NAME=FRL:0..755 [,REQATTL= PCUID ,GLK ,GTS ,T391
,N391 ,N392 ,N393 ,TCONG ,TCONOFF ,FRSTD];
NAME: name
PCUID: pcuIdentifier
GLK: gprsLink
GTS: gprsTimeslot
T391: timer391
N391: n391
N392: n392
N393: n393
TCONG: timeCongestion
TCONOFF: timeCongestionOff


A30808-X3247-M230-6-7619

531
CML:BSC FRL
Id:0900d805800d46c1
GET FRL BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET FRL BASICS
None.
Example of Command Execution:
Get FRL:NAME=FRL:0,REQATTL=PCUID&GLK&GTS&T391&N391&N392&N393&
TCONG&TCONOFF&FRSTD;
GET FRL BASICS
Get FRL BASICS:NAME=FRL:0;
GET FRL BASICS
FRSTD: frameRelayStandard
NAME: name
PCUID: pcuIdentifier
GLK: gprsLink
GTS: gprsTimeslot
T391: timer391
N391: n391
N392: n392
N393: n393
TCONG: timeCongestion
TCONOFF: timeCongestionOff
FRSTD: frameRelayStandard
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET FRL BASICS NAME=FRL:0..755;


532 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL GET FRL BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the FRL object
class.
Long Names:
NAME Addres of the managed object
PCUID pcuIdentifier
GLK gprsLink
GTS gprsTimeSlot
T391 t391
N391 n391
N392 n392
N393 n393
TCONG timeCongestion
TCONOFF timeCongestionOff
FRSTD frameRelayStandard
System Responses:
See GET FRL
Application Guidelines:
See GET FRL
Example of Command Execution:
See GET FRL
GET FRL STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL GET FRL STAT
Applicability:
Phase 2.
Visibility level: 0.
GET FRL STAT NAME=FRL:0..755;


A30808-X3247-M230-6-7619

533
CML:BSC FRL
Id:0900d805800d46c1
Command Description:
This command is used to retrieve the following State/Status attributes related to the FRL
object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get FRL STAT:NAME=FRL:0;
GETINFO FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL GETINFO FRL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the FRL: AST, OST, AVS, CST, PRS.
2. The PCU type and number.
3. The FRL relative number.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO FRL NAME=FRL:0..755;


534 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
4. The FRL internal timeslots map.
5. The FRL speed used.
6. The transmission load percentage (12 samples).
7. The receiving load percentage (12 samples).
8. Six samples of the following counter type in the last 5 minutes are displayed:
crc counter
invalid counter
invalid dlci counter.
9. The list of max 32 DLCIs from network that are not matching.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO FRL ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT FRL:
NAME = FRL:0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
PCU NBR: 2
FRL RELATIVE NUMBER: 5
INTERNAL TIMESLOT MAP: 71 72 73 124
SPEED: 256 KB/S
TX LOAD SAMPLES:
TX LOAD: 30%
... ...
TX LOAD: 30%
RX LOAD SAMPLES:
RX LOAD: 30%
... ...


A30808-X3247-M230-6-7619

535
CML:BSC FRL
Id:0900d805800d46c1
RX LOAD: 30%
CRC LAST 5 MIN (6 SAMPLES): 1 5 9
INVALID LAST 5 MIN (6 SAMPLES): 2 6
INVALID DLCI LAST 5 MIN (6 SAMPLES): 7
DLCI FROM NETWORK NOT MATCHING:
DLCI NR LIST (MAX 32): 19 20 30 54 60 100
210 221 233 256 315
... ...
END OF REPORT
- Operation Failed
GETINFO FRL NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1***
Get Info Report Nack FRL:
name = FRL:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo FRL:NAME=FRL:0;
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


536 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
GETRELATIONSHIP FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL GETRELATIONSHIP FRL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the FRL object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW, PPXU and if the FRL object is connected via A interface,
BSMS and TPWR objects.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship FRL:NAME=FRL:0;
GETSUBO FRL
GETRELATIONSHIP
FRL
NAME=FRL:0..755;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO FRL NAME=FRL:0..755;


A30808-X3247-M230-6-7619

537
CML:BSC FRL
Id:0900d805800d46c1
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL GETSUBO FRL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo FRL:NAME=FRL:0;
LOCK FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL LOCK FRL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
The subordinated NSVC objects shall be put in Disabled-Dependency/offline status,
while the PTPPKFs attested on the same PCU becomes disabled if no NSVC is
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK FRL NAME=FRL:0..755;


538 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
furthermore available. The command can cause services interruption.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock FRL:NAME=FRL:0;
SET FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL SET FRL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the FRL object class. It is used to
assign different time slot to a specific FRL link. The change could be increasing/decreas-
ing the number of time slots or changing the time slot number. For all these actions the
consequent semi-permanent connection shall be changed. The command must be done
in Locked state in order to inform the remote end ot the new link configuration. Also
T391, N391, N392 and N393 can be changed with set command. No lock procedure is
foreseen for changing this attribute.
UNSUCCESSFUL_INVALID_STATUS
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
SET FRL NAME=FRL:0..755 [,GTS=] [,T391=] [,N391=] [,N392=]
[,N393=] [,TCONG=] [,TCONOFF=] [,FRSTD=];


A30808-X3247-M230-6-7619

539
CML:BSC FRL
Id:0900d805800d46c1
Long Names:
NAME Addres of the managed object
GTS gprsTimeSlot
T391 t391
N391 n391
N392 n392
N393 n393
TCONG timeCongestion
TCONOFF timeCongestionOff
FRSTD frameRelayStandard
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
When the GTS attribute is changed the FRL and the
relative TRAU must be in LOCKED state.
The FRSTD parameter can be set only if the FRL
object is in LOCKED state.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The timeslot inserted in the SET FRL command must
not be allocated by other links.
UNSUCCESSFUL_INVALID_TIME_SLOT
The number of timeslots assigned to the FRL must be
compatible with the PCMTYPE attribute of the BSC
object.
UNSUCCESSFUL_NOT_ENOUGH_INT_TSL
The maximum number of FRLs that can be assigned
to a PCU is 63 if the network card is NTWSNAP or
NTWSNAP_STLP.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The attribute TCONOFF can assume one of the fol-
lowing values: 0, 10..30.


540 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46c1
FRL
( I ) The value of the timer T391 set on the BSC side must be lower than the value of the
timer T392 set either on the SGSN or the network side of the Frame Relay link.
Example of Command Execution:
Set FRL:NAME=FRL:3,GTS=2&12,T391=10,N391=50,N392=34,N393=10,
TCONG=20,TCONOFF=25,FRSTD=ITU;
UNLOCK FRL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL FRL UNLOCK FRL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command removes the operator block and the unit remains in the operational state
as it is at the moment of the command. The dependency will be removed from the
subordinate NSVC objects.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_INVALID_STATUS
Application Guidelines:
None.
Example of Command Execution:
Unlock FRL:NAME=FRL:0;
UNLOCK FRL NAME=FRL:0..755;
Successful


A30808-X3247-M230-6-7619

541
CML:BSC GBIPLNK
Id:0900d805800d424b
GBIPLNK
The GBIPLNK object models the connection between the ES and the external router.
This object is explicitely created because the BSC could be configured with ES but
without Gb. The GBIPLNK object has no superordinate. It is possible to create only one
GBIPLNK instance per ES.
CREATE GBIPLNK
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK CREATE GBIPLNK
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the GBIPLNK object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Create GBIPLNK:NAME=GBIPLNK:0;
DELETE GBIPLNK
CREATE GBIPLNK NAME=GBIPLNK:0..1;
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
No GBIPLNK can be created if the TYPOFAMC attribute of BSC
object is set to a value different from ESAM.
DELETE GBIPLNK NAME=GBIPLNK:0..1;


542 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424b
GBIPLNK
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK DELETE GBIPLNK
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the GBIPLNK object class. The
object to be deleted shall be previously locked.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete GBIPLNK:NAME=GBIPLNK:0;
GET GBIPLNK
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK GET GBIPLNK
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve parameter values of an instance of the GBIPLNK
object class.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The GBIPLNK object cannot be deleted if some PCUs have been
equipped with the attribute GBSNS set to IPV4.
GET GBIPLNK NAME=GBIPLNK:0..1;


A30808-X3247-M230-6-7619

543
CML:BSC GBIPLNK
Id:0900d805800d424b
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
Example of Command Execution:
Get GBIPLNK:NAME=GBIPLNK:0;
GET GBIPLNK STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK GET GBIPLNK STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
GBIPLNK object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
NAME: name
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET GBIPLNK STAT NAME=GBIPLNK:0..1;


544 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424b
GBIPLNK
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get GBIPLNK STAT:NAME=GBIPLNK:0;
GETRELATIONSHIP GBIPLNK
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK GETRELATIONSHIP
GBIPLNK
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the GBIPLNK object the related HMOs are the following: EPWR, PWRD, MPCC,
TDPC, MEMT and ES.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETRELATIONSHIP
GBIPLNK
NAME=GBIPLNK:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES


A30808-X3247-M230-6-7619

545
CML:BSC GBIPLNK
Id:0900d805800d424b
Application Guidelines:
None
Example of Command Execution:
Getrelationship GBIPLNK:NAME=GBIPLNK:1;
GETSUBO GBIPLNK
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK GETSUBO GBIPLNK
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo GBIPLNK:NAME=GBIPLNK:0;
The managed object does not provide any relationship attribute.
GETSUBO GBIPLNK NAME=GBIPLNK:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


546 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424b
GBIPLNK
LOCK GBIPLNK
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK LOCK GBIPLNK
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
The command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
The administrative state Locked will survive at the Full Init (and consequently to the load
database).
Example of Command Execution:
Lock GBIPLNK:NAME=GBIPLNK:1;
UNLOCK GBIPLNK
LOCK GBIPLNK NAME=GBIPLNK:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state.
UNLOCK GBIPLNK NAME=GBIPLNK:0..1;


A30808-X3247-M230-6-7619

547
CML:BSC GBIPLNK
Id:0900d805800d424b
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL GBIPLNK UNLOCK GBIPLNK
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked"
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock GBIPLNK:NAME=GBIPLNK:0;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


548 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
HAND
The HAND object provides services to manage the parameters used in the handover
control algorithm.
GET HAND
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND GET HAND
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters used to start the handover process in
case the reception signal strength, the reception quality level or the interference level
are out of limits.
Long Names:
NAME Addres of the managed object
GET HAND NAME=BTSM:0..199/BTS:0..23/HAND:0..0 [,REQATTL=
INTERCH ,INTRACH ,IERCHOSDCCH ,IRACHOSDCCH
,LOTERCH ,LOTRACH ,RXQUALHO ,RXLEVHO ,DISTHO
,PBGTHO ,NCELL ,THORQST ,HOAVLEV ,HOAVQUAL
,HOAVDIST ,HOAVPWRB ,HOLTHLVDL ,HOTDLINT
,HOLTHLVUL ,HOTULINT ,HOLTHQUDL ,HOLTHQUUL
,HOTMSRM ,DPBGTHO ,HIERC ,PL ,HIERF ,CCDIST
,HORXLVDLI ,HORXLVDLO ,HOCCDIST ,ININHO
,CCELL1 ,CCELL2 ,EXTCHO ,HOTMSRME ,HOMSTAM
,HOMRGTA ,NOBAKHO ,NOFREPHO ,MAXFAILHO ,ELIM-
ITCH ,MAIRACHO ,TINOIERCHO ,ERUDGR ,TINHRUGR
,TINHRDGR ,RAVEW ,RUGRUL ,RUGRDL ,RDGRUL
,RDGRDL ,RHOLTQUL ,RHOLTQDL ,EFULHO ,THLEV-
FULHO ,ALEVFULHO ,TRFHOE ,TRFHOT ,TRFKPRI
,TRFHITH ,TRFLTH ,TRFMMA ,TRFMS ,ELEVHOM
,ENAQUALEVHOM ,AMRACMRDL ,HOLTHQAMRDL
,HOLTHQAMRUL ,HOTHAMRCDL ,HOTHAMRCUL
,HOTHAMRDDL ,HOTHAMRDUL ,EUHO ,EUBCHO
,EUSCHO ,EUIMPHO ,SG1HOPAR ,SG2HOPAR
,SG3HOPAR ,SG4HOPAR ,SG5HOPAR ,SG6HOPAR
,SG7HOPAR ,SG8HOPAR ,SG9HOPAR ,SG10HOPAR
,SG11HOPAR ,SG12HOPAR ,SG13HOPAR ,SG14HOPAR
,EADVCMPDCMHO ,HOTHCMPLVDL ,HOTHCMPLVUL
,HOTHDCMLVDL ,HOTHDCMLVUL ,HOTHEFRCDL
,HOTHEFRCUL ,HOTHFRCDL ,HOTHFRCUL ,HOTH-
HRDDL ,HOTHHRDUL ,EADVCMPHOAMR ,EADVCM-
PHOSC ,ADVCMPHOOAMR ,HRDCMLIMTH];


A30808-X3247-M230-6-7619

549
CML:BSC HAND
Id:0900d805800d424e
INTERCH enableInterCellHo
INTRACH enableIntraCellHo
IERCHOSDCCH enableInterCellHoSdcch
IRACHOSDCCH enableIntraCellHoSdcch
LOTERCH enableLocalInterCellHo
LOTRACH enableLocalIntraCellHo
RXQUALHO enableRxQualHo
RXLEVHO enableRxLevHo
DISTHO enableDistanceHo
PBGTHO enablePowerBudgetHo
NCELL nCell
THORQST timerHoRequest
HOAVLEV hoAveragingLev
HOAVQUAL hoAveragingQual
HOAVDIST hoAveragingDistance
HOAVPWRB hoAveragingPowerBudget
HOLTHLVDL hoLowerThresholdLevDL
HOTDLINT hoThresholdLevDLintra
HOLTHLVUL hoLowerThresholdLevUL
HOTULINT hoThresholdLevULintra
HOLTHQUDL hoLowerThresholdQualDL
HOLTHQUUL hoLowerThresholdQualUL
HOTMSRM hoThresholdMsRangeMax
DPBGTHO enableDelayPowerBudgetHo
HIERC enableHierarchicalCellHo
PL priorityLayer
HIERF hierarchicalCellRankFlag
CCDIST enableConCellDist
HORXLVDLI hoRxLevDLinner
HORXLVDLO hoRxLevDLouter
HOCCDIST hoConcentricCellDistance
ININHO enableInnerInnerHo
CCELL1 collocatedCell1
CCELL2 collocatedCell2
EXTCHO enableExtendedCellHo
HOTMSRME hoThresholdMsRangeMaxExt
HOMSTAM hoMsTaMax
HOMRGTA hoMarginTa
NOBAKHO enableNobackHo


550 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
NOFREPHO enableNoFailRepHo
MAXFAILHO maxFailHo
ELIMITCH enableLimitationIntraCellHo
MAIRACHO maxIntraCellHandover
TINOIERCHO timerNoIntraCellHo
ERUDGR enableRateUpDowngrade
TINHRUGR timerInhibitRateUpgrade
TINHRDGR timerInhibitRateDowngrade
RAVEW rateAveragingWindow
RUGRUL rateUpgradeUplink
RUGRDL rateUpgradeDownlink
RDGRUL rateDowngradeUplink
RDGRDL rateDowngradeDownlink
RHOLTQUL rateHoLowerThresholdQualUplink
RHOLTQDL rateHoLowerThresholdQualDownlink
EFULHO enableFastUpLinkHo
THLEVFULHO thresholdLevFastULHo
ALEVFULHO averagedLevFastULHo
TRFHOE trafficHandoverEnable
TRFHOT trafficHandoverTimer
TRFKPRI trafficKeepPriority
TRFHITH trafficHighThreshold
TRFLTH trafficLowThreshold
TRFMMA trafficMarginMaximum
TRFMS trafficMarginStep
ELEVHOM enableLevHOMargin
ENAQUALEVHOM enableQualityLeveHOMargin
AMRACMRDL aMRAveragedCMRDL
HOLTHQAMRDL hoLowerThresQualAMRDL
HOLTHQAMRUL hoLowerThresQualAMRUL
HOTHAMRCDL hoThresAMRComprDL
HOTHAMRCUL hoThresAMRComprUL
HOTHAMRDDL hoThresAMRDecomprDL
HOTHAMRDUL hoThresAMRDecomprUL
EUHO enableHoFromGsmToUmts
EUBCHO enableBetterCellHoToUmts
EUSCHO enableSufficientUmtsCoverageHoToUmts
EUIMPHO enableImperativeHoToUmts
SG1HOPAR sg1HandoverParms


A30808-X3247-M230-6-7619

551
CML:BSC HAND
Id:0900d805800d424e
SG2HOPAR sg2HandoverParms
SG3HOPAR sg3HandoverParms
SG4HOPAR sg4HandoverParms
SG5HOPAR sg5HandoverParms
SG6HOPAR sg6HandoverParms
SG7HOPAR sg7HandoverParms
SG8HOPAR sg8HandoverParms
SG9HOPAR sg9HandoverParms
SG10HOPAR sg10HandoverParms
SG11HOPAR sg11HandoverParms
SG12HOPAR sg12HandoverParms
SG13HOPAR sg13HandoverParms
SG14HOPAR sg14HandoverParms
EADVCMPDCMHO enableAdvComprDecomprHO
HOTHCMPLVDL hoThresComprLevDL
HOTHCMPLVUL hoThresComprLevUL
HOTHDCMLVDL hoThresDecomprLevDL
HOTHDCMLVUL hoThresDecomprLevUL
HOTHEFRCDL hoThresholdEFRComprDL
HOTHEFRCUL hoThresholdEFRComprUL
HOTHFRCDL hoThresholdFRComprDL
HOTHFRCUL hoThresholdFRComprUL
HOTHHRDDL hoThresholdHRDecomprDL
HOTHHRDUL hoThresholdHRDecomprUL
EADVCMPHOAMR enableAdvComprHoAMR
EADVCMPHOSC enableAdvComprHoSC
ADVCMPHOOAMR advComprHOffsetAMR
HRDCMLIMTH hRDecomprLimitThreshold
System Responses:
- Operation Completed
NAME = name
INTERCH = enableInterCellHo
INTRACH = enableIntraCellHo
LOTERCH = enableLocalInterCellHo
LOTRACH = enableLocalIntraCellHo
RXQUALHO = enableRxQualHO,
RXLEVHO = enableRxLevHO,
DISTHO = enableDistanceHO,


552 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
PBGTHO = enablePowerBudgetHO,
NCELL = nCell,
THORQST = timerHORequest,
HOAVLEV = hoAveragingLev
A_Lev_ho
W_Lev_ho
HOAVQUAL = hoAveragingQual
A_Qual_ho
W_Qual_ho
HOAVDIST = hoAveragingDistance,
HOAVPWRB = hoAverPwrBud,
HOLTHLVDL = hoLowerThresholdLevDL,
HOTDLINT = hoThresholdLevDLintra,
HOLTHLVUL = hoLowerThresholdLevUL,
HOTULINT = hoThresholdlevULintra,
HOLTHQUDL = hoLowerThresholdQualDL,
HOLTHQUUL = hoLowerThresholdQualUL,
HOTMSRM = hoThresholdMsRangeMax,
DPBGTHO = enableDelayPowerBudgetHo,
HIERC = enableHierarchicalCellHo,
PL = priorityLayer,
HIERF = hierarchicalCellRankFlag,
CCDIST = enableConcCellDist,
HORXLVDLI = hoRxlevDlinner,
HORXLVDLO = hoRxlevDLouter,
HOCCDIST = hoConcentricCellDistance,
ININHO = enableInnerInnerHo,
CCELL1 = collocatedCell1,
CCELL2 = collocatedCell2,
EXTCHO = enableExtendedCellHo,
HOTMSRME = hoThresholdMsRangeMaxEx,
HOMSTAM = hoMsTaMax,
HOMRGTA = hoMarginTa(Km),
NOBAKHO = enableNobackHo,
NOFREPHO = enableNoFailRepHo,
MAXFAILHO = maxFailHo,


A30808-X3247-M230-6-7619

553
CML:BSC HAND
Id:0900d805800d424e
ELIMITCH = enableLimitationIntraCellHo,
MAIRACHO = maxIntraCellHandover,
TINOIERCHO = timerNoIntraCellHo;
IERCHOSDCCH=enableInterCellHoSdcch
IRACHOSDCCH=enableIntraCellHoSdcch
ERUDGR = enableRateUpDowngrade
TINHRUGR = timerInhibitRateUpgrade
TINHRDGR = timerInhibitRateDwngrade
RAVEW = rateAveragingWindow
RUGRUL = rateUpgradeUL
RUGRDL = rateUpgradeDL
RDGRUL = rateDowngradeUL
RDGRDL = rateDowngradeDL
RHOLTQDL = rateHoLowerThresholdQualDL
RHOLTQUL = rateHoLowerThresholdQualUL
EFULHO:enableFastUpLinkHO
THLEVFULHO:thresholdLevFastULHo
ALEVFULHO:averagedLevFastULHO
TRFHOE:trafficHandoverEnable
TRFHOT:trafficHandoverTimer
TRFKPRI:trafficKeepPriority
TRFHITH:trafficHighThreshold
TRFLTH:trafficLowThreshold
TRFMMA:trafficMarginMaximum
TRFMS:trafficMarginStep
ELEVHOM:enableLevHOMargin
AMRACMRDL:aMRAveragedCMRDL
HOLTHQAMRDL:hoLowerThresQualAMRDL
HOLTHQAMRUL:hoLowerThresQualAMRUL
HOTHAMRCDL:hoThresAMRComprDL
HOTHAMRCUL:hoThresAMRComprUL
HOTHAMRDDL:hoThresAMRDecomprDL
HOTHAMRDUL:hoThresAMRDecomprUL
EUHO:enableHoFromGsmToUmts
EUBCHO:enableBetterCellHoToUmts
EUSCHO:enableSufficientUmtsCoverageHoToUmts


554 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
EUIMPHO:enableImperativeHoToUmts
SG1HOPAR:sg1HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
SG2HOPAR:sg2HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
SG3HOPAR:sg3HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresEFRComprDL
hoThresEFRComprUL
hoThresFRComprDL
hoThresFRComprUL
SG4HOPAR:sg4HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra


A30808-X3247-M230-6-7619

555
CML:BSC HAND
Id:0900d805800d424e
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresEFRComprDL
hoThresEFRComprUL
hoThresFRComprDL
hoThresFRComprUL
SG5HOPAR:sg5HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresHRDecomprDL
hoThresHRDecomprUL
SG6HOPAR:sg6HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresHRDecomprDL
hoThresHRDecomprUL
SG7HOPAR:sg7HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra


556 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG8HOPAR:sg8HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG9HOPAR:sg9HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG10HOPAR:sg10HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL


A30808-X3247-M230-6-7619

557
CML:BSC HAND
Id:0900d805800d424e
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG11HOPAR:sg11HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRComprDL
hoThresAMRComprUL
SG12HOPAR:sg12HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRComprDL
hoThresAMRComprUL
SG13HOPAR:sg13HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter


558 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRDecomprDL
hoThresAMRDecomprUL
SG14HOPAR:sg14HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRDecomprDL
hoThresAMRDecomprUL
EADVCMPDCMHO: enableAdvComprDecomprHO
HOTHCMPLVDL: hoThresComprLevDL
HOTHCMPLVUL: hoThresComprLevUL
HOTHDMPLVDL: hoThresDecomprLevDL
HOTHDMPLVUL: hoThresDecomprLevUL
HOTHEFRCDL: hoThresEFRComprDL
HOTHEFRCUL: hoThresEFRComprUL
HOTHFRCDL: hoThresFRComprDL
HOTHFRCUL: hoThresFRComprUL
HOTHHRDDL: hoThresHRDecomprDL
HOTHHRDUL: hoThresHRDecomprUL
EADVCMPHOAMR: enableAdvComprHOAMR
EADVCMPHOSC: enableAdvComprHOSC
ADVCMPHOOAMR:advComprHoOffsetAMR
HRDCMLIMTH:hRDecomprLimitThres
ENAQUALEVHOM: enableQualityLevelHoMargin


A30808-X3247-M230-6-7619

559
CML:BSC HAND
Id:0900d805800d424e
GET HAND BASICS
INTERCH = enableInterCellHo
INTRACH = enableIntraCellHo
LOTERCH = enableLocalInterCellHo
LOTRACH = enableLocalIntraCellHo
RXQUALHO = enableRxQualHO,
RXLEVHO = enableRxLevHO,
DISTHO = enableDistanceHO,
PBGTHO = enablePowerBudgetHO,
NCELL = nCell,
THORQST = timerHORequest,
HOAVLEV = hoAveragingLev
A_Lev_ho
W_Lev_ho
HOAVQUAL = hoAveragingQual
A_Qual_ho
W_Qual_ho
HOAVDIST = hoAveragingDistance,
HOAVPWRB = hoAverPwrBud,
HOLTHLVDL = hoLowerThresholdLevDL,
HOTDLINT = hoThresholdLevDLintra,
HOLTHLVUL = hoLowerThresholdLevUL,
HOTULINT = hoThresholdlevULintra,
HOLTHQUDL = hoLowerThresholdQualDL,
HOLTHQUUL = hoLowerThresholdQualUL,
HOTMSRM = hoThresholdMsRangeMax,
DPBGTHO = enableDelayPowerBudgetHo,
HIERC = enableHierarchicalCellHo,
PL = priorityLayer,
HIERF = hierarchicalCellRankFlag,
CCDIST = enableConcCellDist,
HORXLVDLI = hoRxlevDlinner,
HORXLVDLO = hoRxlevDLouter,
HOCCDIST = hoConcentricCellDistance,
ININHO = enableInnerInnerHo,
CCELL1 = collocatedCell1,


560 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
CCELL2 = collocatedCell2,
EXTCHO = enableExtendedCellHo,
HOTMSRME = hoThresholdMsRangeMaxEx,
HOMSTAM = hoMsTaMax,
HOMRGTA = hoMarginTa(Km),
NOBAKHO = enableNobackHo,
NOFREPHO = enableNoFailRepHo,
MAXFAILHO = maxFailHo,
ELIMITCH = enableLimitationIntraCellHo,
MAIRACHO = maxIntraCellHandover,
TINOIERCHO = timerNoIntraCellHo;
IERCHOSDCCH=enableInterCellHoSdcch
IRACHOSDCCH=enableIntraCellHoSdcch
EFULHO:enableFastUpLinkHO
THLEVFULHO:thresholdLevFastULHo
ALEVFULHO:averagedLevFastULHO
TRFHOE:trafficHandoverEnable
TRFHOT:trafficHandoverTimer
TRFKPRI:trafficKeepPriority
TRFHITH:trafficHighThreshold
TRFLTH:trafficLowThreshold
TRFMMA:trafficMarginMaximum
TRFMS:trafficMarginStep
ELEVHOM:enableLevHOMargin
AMRACMRDL:aMRAveragedCMRDL
HOLTHQAMRDL:hoLowerThresQualAMRDL
HOLTHQAMRUL:hoLowerThresQualAMRUL
HOTHAMRCDL:hoThresAMRComprDL
HOTHAMRCUL:hoThresAMRComprUL
HOTHAMRDDL:hoThresAMRDecomprDL
HOTHAMRDUL:hoThresAMRDecomprUL
EUHO:enableHoFromGsmToUmts
EUBCHO:enableBetterCellHoToUmts
EUSCHO:enableSufficientUmtsCoverageHoToUmts
EUIMPHO:enableImperativeHoToUmts
SG1HOPAR:sg1HandoverParms


A30808-X3247-M230-6-7619

561
CML:BSC HAND
Id:0900d805800d424e
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
SG2HOPAR:sg2HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
SG3HOPAR:sg3HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresEFRComprDL
hoThresEFRComprUL
hoThresFRComprDL
hoThresFRComprUL
SG4HOPAR:sg4HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner


562 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresEFRComprDL
hoThresEFRComprUL
hoThresFRComprDL
hoThresFRComprUL
SG5HOPAR:sg5HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresHRDecomprDL
hoThresHRDecomprUL
SG6HOPAR:sg6HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoThresHRDecomprDL
hoThresHRDecomprUL
SG7HOPAR:sg7HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter


A30808-X3247-M230-6-7619

563
CML:BSC HAND
Id:0900d805800d424e
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG8HOPAR:sg8HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG9HOPAR:sg9HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL
rateHoLowerThresholdQualUL
SG10HOPAR:sg10HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
rateHoLowerThresholdQualDL


564 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
rateHoLowerThresholdQualUL
SG11HOPAR:sg11HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRComprDL
hoThresAMRComprUL
SG12HOPAR:sg12HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRComprDL
hoThresAMRComprUL
SG13HOPAR:sg13HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL


A30808-X3247-M230-6-7619

565
CML:BSC HAND
Id:0900d805800d424e
GET HAND DATA
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRDecomprDL
hoThresAMRDecomprUL
SG14HOPAR:sg14HandoverParms
hoLowerThresholdLevDL
hoLowerThresholdLevUL
hoThresholdLevDLintra
hoThresholdLevULintra
hoRxlevDLinner
hoRxlevDLouter
hoLowerThresholdQualDL
hoLowerThresholdQualUL
hoLowerThresQualAMRDL
hoLowerThresQualAMRUL
hoThresAMRDecomprDL
hoThresAMRDecomprUL
EADVCMPDCMHO: enableAdvComprDecomprHO
HOTHCMPLVDL: hoThresComprLevDL
HOTHCMPLVUL: hoThresComprLevUL
HOTHDMPLVDL: hoThresDecomprLevDL
HOTHDMPLVUL: hoThresDecomprLevUL
HOTHEFRCDL: hoThresEFRComprDL
HOTHEFRCUL: hoThresEFRComprUL
HOTHFRCDL: hoThresFRComprDL
HOTHFRCUL: hoThresFRComprUL
HOTHHRDDL: hoThresHRDecomprDL
HOTHHRDUL: hoThresHRDecomprUL
EADVCMPHOAMR: enableAdvComprHOAMR
EADVCMPHOSC: enableAdvComprHOSC
ADVCMPHOOAMR:advComprHoOffsetAMR
HRDCMLIMTH:hRDecomprLimitThres
ENAQUALEVHOM: enableQualityLevelHoMargin
ERUDGR = enableRateUpDowngrade


566 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET HAND BASICS
None
GET HAND DATA
None.
Example of Command Execution:
Get HAND:NAME=BTSM:0/BTS:0/HAND:0,REQATTL=INTERCH&INTRACH&
IERCHOSDCCH&IRACHOSDCCH&LOTERCH&LOTRACH&RXQUALHO&
RXLEVHO&DISTHO&PBGTHO&NCELL&THORQST&HOAVLEV&HOAVQUAL&
HOAVDIST&HOAVPWRB&HOLTHLVDL&HOTDLINT&HOLTHLVUL&HOTULINT&
HOLTHQUDL&HOLTHQUUL&HOTMSRM&DPBGTHO&HIERC&PL&HIERF&
CCDIST&HORXLVDLI&HORXLVDLO&HOCCDIST&ININHO&CCELL1&CCELL2&
EXTCHO&HOTMSRME&HOMSTAM&HOMRGTA&NOBAKHO&NOFREPHO&
MAXFAILHO&ELIMITCH&MAIRACHO&TINOIERCHO&ERUDGR&TINHRUGR&
TINHRDGR&RAVEW&RUGRUL&RUGRDL&RDGRUL&RDGRDL&RHOLTQUL&
RHOLTQDL&EFULHO&THLEVFULHO&ALEVFULHO&TRFHOE&TRFHOT&
TRFKPRI&TRFHITH&TRFLTH&TRFMMA&TRFMS&ELEVHOM&AMRACMRDL&
HOLTHQAMRDL&HOLTHQAMRUL&HOTHAMRCDL&HOTHAMRCUL&
HOTHAMRDDL&HOTHAMRDUL&EUHO&EUBCHO&EUSCHO&EUIMPHO&
SG1HOPAR&SG2HOPAR&SG3HOPAR&SG4HOPAR&SG5HOPAR&SG6HOPAR&
TINHRUGR = timerInhibitRateUpgrade
TINHRDGR = timerInhibitRateDwngrade
RAVEW = rateAveragingWindow
RUGRUL = rateUpgradeUL
RUGRDL = rateUpgradeDL
RDGRUL = rateDowngradeUL
RDGRDL = rateDowngradeDL
RHOLTQDL = rateHoLowerThresholdQualDL
RHOLTQUL = rateHoLowerThresholdQualUL
NOT_EQUIPPED
The object instance must be already created.


A30808-X3247-M230-6-7619

567
CML:BSC HAND
Id:0900d805800d424e
SG7HOPAR&SG8HOPAR&SG9HOPAR&SG10HOPAR&SG11HOPAR&
SG12HOPAR&SG13HOPAR&SG14HOPAR&EADVCMPDCMHO&HOTHCM-
PLVDL&HOTHCMPLVUL&HOTHDMPLVDL&HOTHDMPLVUL&HOTHE-
FRCDL&HOTHEFRCUL&HOTHFRCDL&HOTHFRCUL&HOTHHRDDL&HOTHHRDU
L&EADVCMPHOAMR&EADVCMPHOSC&ADVCMPHOOAMR&HRDCM-
LIMTH&ENAQUALEVHOM;
GET HAND BASICS
Get HAND BASICS:NAME=BTSM:0/BTS:0/HAND:0;
GET HAND DATA
Get HAND DATA:NAME=BTSM:0/BTS:0/HAND:0;
GET HAND BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND GET HAND
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters used to start the handover process in
case the reception signal strength, the reception quality level or the interference level
are out of limits.
Long Names:
NAME Addres of the managed object
INTERCH enableInterCellHo
INTRACH enableIntraCellHo
IERCHOSDCCH enableInterCellHoSdcch
IRACHOSDCCH enableIntraCellHoSdcch
LOTERCH enableLocalInterCellHo
LOTRACH enableLocalIntraCellHo
RXQUALHO enableRxQualHo
RXLEVHO enableRxLevHo
DISTHO enableDistanceHo
PBGTHO enablePowerBudgetHo
NCELL nCell
GET HAND BASICS NAME=BTSM:0..199/BTS:0..23/HAND:0..0;


568 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
THORQST timerHoRequest
HOAVLEV hoAveragingLev
HOAVQUAL hoAveragingQual
HOAVDIST hoAveragingDistance
HOAVPWRB hoAveragingPowerBudget
HOLTHLVDL hoLowerThresholdLevDL
HOTDLINT hoThresholdLevDLintra
HOLTHLVUL hoLowerThresholdLevUL
HOTULINT hoThresholdLevULintra
HOLTHQUDL hoLowerThresholdQualDL
HOLTHQUUL hoLowerThresholdQualUL
HOTMSRM hoThresholdMsRangeMax
DPBGTHO enableDelayPowerBudgetHo
HIERC enableHierarchicalCellHo
PL priorityLayer
HIERF hierarchicalCellRankFlag
CCDIST enableConCellDist
HORXLVDLI hoRxLevDLinner
HORXLVDLO hoRxLevDLouter
HOCCDIST hoConcentricCellDistance
ININHO enableInnerInnerHo
CCELL1 collocatedCell1
CCELL2 collocatedCell2
EXTCHO enableExtendedCellHo
HOTMSRME hoThresholdMsRangeMaxExt
HOMSTAM hoMsTaMax
HOMRGTA hoMarginTa
NOBAKHO enableNobackHo
NOFREPHO enableNoFailRepHo
MAXFAILHO maxFailHo
ELIMITCH enableLimitationIntraCellHo
MAIRACHO maxIntraCellHandover
TINOIERCHO timerNoIntraCellHo
EFULHO enableFastUpLinkHo
THLEVFULHO thresholdLevFastULHo
ALEVFULHO averagedLevFastULHo
TRFHOE trafficHandoverEnable
TRFHOT trafficHandoverTimer
TRFKPRI trafficKeepPriority


A30808-X3247-M230-6-7619

569
CML:BSC HAND
Id:0900d805800d424e
TRFHITH trafficHighThreshold
TRFLTH trafficLowThreshold
TRFMMA trafficMarginMaximum
TRFMS trafficMarginStep
ELEVHOM enableLevHOMargin
ENAQUALEVHOM enableQualityLeveHOMargin
AMRACMRDL aMRAveragedCMRDL
HOLTHQAMRDL hoLowerThresQualAMRDL
HOLTHQAMRUL hoLowerThresQualAMRUL
HOTHAMRCDL hoThresAMRComprDL
HOTHAMRCUL hoThresAMRComprUL
HOTHAMRDDL hoThresAMRDecomprDL
HOTHAMRDUL hoThresAMRDecomprUL
EUHO enableHoFromGsmToUmts
EUBCHO enableBetterCellHoToUmts
EUSCHO enableSufficientUmtsCoverageHoToUmts
EUIMPHO enableImperativeHoToUmts
SG1HOPAR sg1HandoverParms
SG2HOPAR sg2HandoverParms
SG3HOPAR sg3HandoverParms
SG4HOPAR sg4HandoverParms
SG5HOPAR sg5HandoverParms
SG6HOPAR sg6HandoverParms
SG7HOPAR sg7HandoverParms
SG8HOPAR sg8HandoverParms
SG9HOPAR sg9HandoverParms
SG10HOPAR sg10HandoverParms
SG11HOPAR sg11HandoverParms
SG12HOPAR sg12HandoverParms
SG13HOPAR sg13HandoverParms
SG14HOPAR sg14HandoverParms
EADVCMPDCMHO enableAdvComprDecomprHO
HOTHCMPLVDL hoThresComprLevDL
HOTHCMPLVUL hoThresComprLevUL
HOTHDCMLVDL hoThresDecomprLevDL
HOTHDCMLVUL hoThresDecomprLevUL
HOTHEFRCDL hoThresholdEFRComprDL
HOTHEFRCUL hoThresholdEFRComprUL
HOTHFRCDL hoThresholdFRComprDL


570 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
HOTHFRCUL hoThresholdFRComprUL
HOTHHRDDL hoThresholdHRDecomprDL
HOTHHRDUL hoThresholdHRDecomprUL
EADVCMPHOAMR enableAdvComprHoAMR
EADVCMPHOSC enableAdvComprHoSC
ADVCMPHOOAMR advComprHOffsetAMR
HRDCMLIMTH hRDecomprLimitThreshold
System Responses:
See GET HAND
Application Guidelines:
See GET HAND
Example of Command Execution:
See GET HAND
GET HAND DATA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND GET HAND
DATA
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters used to start the handover process in
case the reception signal strength, the reception quality level or the interference level
are out of limits.
Long Names:
NAME Addres of the managed object
ERUDGR enableRateUpDowngrade
TINHRUGR timerInhibitRateUpgrade
TINHRDGR timerInhibitRateDowngrade
RAVEW rateAveragingWindow
RUGRUL rateUpgradeUplink
RUGRDL rateUpgradeDownlink
RDGRUL rateDowngradeUplink
RDGRDL rateDowngradeDownlink
GET HAND DATA NAME=BTSM:0..199/BTS:0..23/HAND:0..0;


A30808-X3247-M230-6-7619

571
CML:BSC HAND
Id:0900d805800d424e
RHOLTQUL rateHoLowerThresholdQualUplink
RHOLTQDL rateHoLowerThresholdQualDownlink
System Responses:
See GET HAND
Application Guidelines:
See GET HAND
Example of Command Execution:
See GET HAND
SET HAND
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS HAND SET HAND
SET HAND NAME=BTSM:0..199/BTS:0..23/HAND:0..0 [,INTERCH=]
[,INTRACH=] [,IERCHOSDCCH=] [,IRACHOSDCCH=]
[,LOTERCH=] [,LOTRACH=] [,RXQUALHO=] [,RXLEVHO=]
[,DISTHO=] [,PBGTHO=] [,NCELL=] [,THORQST=] [,HOAV-
LEV=] [,HOAVQUAL=] [,HOAVDIST=] [,HOAVPWRB=]
[,HOLTHLVDL=] [,HOTDLINT=] [,HOLTHLVUL=] [,HOTU-
LINT=] [,HOLTHQUDL=] [,HOLTHQUUL=] [,HOTMSRM=]
[,DPBGTHO=] [,HIERC=] [,PL=] [,HIERF=] [,CCDIST=]
[,HORXLVDLI=] [,HORXLVDLO=] [,HOCCDIST=]
[,ININHO=] [,CCELL1=] [,CCELL2=] [,EXTCHO=] [,HOTM-
SRME=] [,HOMSTAM=] [,HOMRGTA=] [,NOBAKHO=]
[,NOFREPHO=] [,MAXFAILHO=] [,ELIMITCH=] [,MAIRA-
CHO=] [,TINOIERCHO=] [,ERUDGR=] [,TINHRUGR=]
[,TINHRDGR=] [,RAVEW=] [,RUGRUL=] [,RUGRDL=]
[,RDGRUL=] [,RDGRDL=] [,RHOLTQUL=] [,RHOLTQDL=]
[,EFULHO=] [,THLEVFULHO=] [,ALEVFULHO=] [,TRF-
HOE=] [,TRFHOT=] [,TRFKPRI=] [,TRFHITH=] [,TRFLTH=]
[,TRFMMA=] [,TRFMS=] [,ELEVHOM=] [,ENAQUA-
LEVHOM=] [,AMRACMRDL=] [,HOLTHQAMRDL=]
[,HOLTHQAMRUL=] [,HOTHAMRCDL=] [,HOTHAMRCUL=]
[,HOTHAMRDDL=] [,HOTHAMRDUL=] [,EUHO=] [,EUB-
CHO=] [,EUSCHO=] [,EUIMPHO=] [,SG1HOPAR=]
[,SG2HOPAR=] [,SG3HOPAR=] [,SG4HOPAR=]
[,SG5HOPAR=] [,SG6HOPAR=] [,SG7HOPAR=]
[,SG8HOPAR=] [,SG9HOPAR=] [,SG10HOPAR=]
[,SG11HOPAR=] [,SG12HOPAR=] [,SG13HOPAR=]
[,SG14HOPAR=] [,EADVCMPDCMHO=] [,HOTHCM-
PLVDL=] [,HOTHCMPLVUL=] [,HOTHDCMLVDL=] [,HOTH-
DCMLVUL=] [,HOTHEFRCDL=] [,HOTHEFRCUL=]
[,HOTHFRCDL=] [,HOTHFRCUL=] [,HOTHHRDDL=]
[,HOTHHRDUL=] [,EADVCMPHOAMR=] [,EADVCM-
PHOSC=] [,ADVCMPHOOAMR=] [,HRDCMLIMTH=];


572 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the parameters used to start the Handover process in case the
reception signal strength, the reception quality level or the interference level are out of
bounds.
Long Names:
NAME Addres of the managed object
INTERCH enableInterCellHo
INTRACH enableIntraCellHo
IERCHOSDCCH enableInterCellHoSdcch
IRACHOSDCCH enableIntraCellHoSdcch
LOTERCH enableLocalInterCellHo
LOTRACH enableLocalIntraCellHo
RXQUALHO enableRxQualHo
RXLEVHO enableRxLevHo
DISTHO enableDistanceHo
PBGTHO enablePowerBudgetHo
NCELL nCell
THORQST timerHoRequest
HOAVLEV hoAveragingLev
HOAVQUAL hoAveragingQual
HOAVDIST hoAveragingDistance
HOAVPWRB hoAveragingPowerBudget
HOLTHLVDL hoLowerThresholdLevDL
HOTDLINT hoThresholdLevDLintra
HOLTHLVUL hoLowerThresholdLevUL
HOTULINT hoThresholdLevULintra
HOLTHQUDL hoLowerThresholdQualDL
HOLTHQUUL hoLowerThresholdQualUL
HOTMSRM hoThresholdMsRangeMax
DPBGTHO enableDelayPowerBudgetHo
HIERC enableHierarchicalCellHo
PL priorityLayer
HIERF hierarchicalCellRankFlag
CCDIST enableConCellDist
HORXLVDLI hoRxLevDLinner
HORXLVDLO hoRxLevDLouter


A30808-X3247-M230-6-7619

573
CML:BSC HAND
Id:0900d805800d424e
HOCCDIST hoConcentricCellDistance
ININHO enableInnerInnerHo
CCELL1 collocatedCell1
CCELL2 collocatedCell2
EXTCHO enableExtendedCellHo
HOTMSRME hoThresholdMsRangeMaxExt
HOMSTAM hoMsTaMax
HOMRGTA hoMarginTa
NOBAKHO enableNobackHo
NOFREPHO enableNoFailRepHo
MAXFAILHO maxFailHo
ELIMITCH enableLimitationIntraCellHo
MAIRACHO maxIntraCellHandover
TINOIERCHO timerNoIntraCellHo
ERUDGR enableRateUpDowngrade
TINHRUGR timerInhibitRateUpgrade
TINHRDGR timerInhibitRateDowngrade
RAVEW rateAveragingWindow
RUGRUL rateUpgradeUplink
RUGRDL rateUpgradeDownlink
RDGRUL rateDowngradeUplink
RDGRDL rateDowngradeDownlink
RHOLTQUL rateHoLowerThresholdQualUplink
RHOLTQDL rateHoLowerThresholdQualDownlink
EFULHO enableFastUpLinkHo
THLEVFULHO thresholdLevFastULHo
ALEVFULHO averagedLevFastULHo
TRFHOE trafficHandoverEnable
TRFHOT trafficHandoverTimer
TRFKPRI trafficKeepPriority
TRFHITH trafficHighThreshold
TRFLTH trafficLowThreshold
TRFMMA trafficMarginMaximum
TRFMS trafficMarginStep
ELEVHOM enableLevHOMargin
ENAQUALEVHOM enableQualityLeveHOMargin
AMRACMRDL aMRAveragedCMRDL
HOLTHQAMRDL hoLowerThresQualAMRDL
HOLTHQAMRUL hoLowerThresQualAMRUL


574 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
HOTHAMRCDL hoThresAMRComprDL
HOTHAMRCUL hoThresAMRComprUL
HOTHAMRDDL hoThresAMRDecomprDL
HOTHAMRDUL hoThresAMRDecomprUL
EUHO enableHoFromGsmToUmts
EUBCHO enableBetterCellHoToUmts
EUSCHO enableSufficientUmtsCoverageHoToUmts
EUIMPHO enableImperativeHoToUmts
SG1HOPAR sg1HandoverParms
SG2HOPAR sg2HandoverParms
SG3HOPAR sg3HandoverParms
SG4HOPAR sg4HandoverParms
SG5HOPAR sg5HandoverParms
SG6HOPAR sg6HandoverParms
SG7HOPAR sg7HandoverParms
SG8HOPAR sg8HandoverParms
SG9HOPAR sg9HandoverParms
SG10HOPAR sg10HandoverParms
SG11HOPAR sg11HandoverParms
SG12HOPAR sg12HandoverParms
SG13HOPAR sg13HandoverParms
SG14HOPAR sg14HandoverParms
EADVCMPDCMHO enableAdvComprDecomprHO
HOTHCMPLVDL hoThresComprLevDL
HOTHCMPLVUL hoThresComprLevUL
HOTHDCMLVDL hoThresDecomprLevDL
HOTHDCMLVUL hoThresDecomprLevUL
HOTHEFRCDL hoThresholdEFRComprDL
HOTHEFRCUL hoThresholdEFRComprUL
HOTHFRCDL hoThresholdFRComprDL
HOTHFRCUL hoThresholdFRComprUL
HOTHHRDDL hoThresholdHRDecomprDL
HOTHHRDUL hoThresholdHRDecomprUL
EADVCMPHOAMR enableAdvComprHoAMR
EADVCMPHOSC enableAdvComprHoSC
ADVCMPHOOAMR advComprHOffsetAMR
HRDCMLIMTH hRDecomprLimitThreshold
System Responses:
- Operation Completed


A30808-X3247-M230-6-7619

575
CML:BSC HAND
Id:0900d805800d424e
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
When the excessive distance is enabled (attribute EEXCDIST
of BTS object), the value assigned to the attribute excessiveDis-
tance (attribute EXCDIST of BTS object) must be greater than
the value assigned to the other Distance Handover Thresholds:
hoThresholdMsRangeMax (attribute HOTMSRM of HAND
object) in case of Standard Cell and Dual Band Standard Cell
hoThresholdMsRangeMaxExt (attribute HOTMSRME of HAND
object) in case of Extended Cell.
LAST_ADJC_RESERVED_FOR_LOTRACH
When the intracell handovers are MSC controlled (attribute
LOTRACH of HAND object set at FALSE) one of the 32 allowed
active ADJCs is reserved by BSC for LOTRACH handling, so in
this case the operator can configure only 31 active ADJC cells.
UNSUCCESSFUL_INVALID_STATUS
In order to set LOTRACH parameter, the SCA object related to
the BTS must be in LOCKED state.
INCOMP_NESWLOAD_VS_MESSAGE
When the SGXHOPAR attribute, X = 1..14, is different from
NULL, SGXHOPAR fields override the unspecific attributes
shared among service groups, as shown in Appendix C.
For every SGXHOPAR, X = 1..14:
The attribute must be set at NULL value if the Expected SW
version belongs to BR6.0 release (see EXPSWV parameter
description).
The EUHO, EUBCHO, EUSCHO, EUIMPHO attributes must be
set at FALSE if the Software version running on the
superordinate BTSM object belongs to BR6.0 release (see
EXPSWV parameter description).
If the superordinate BTSM SW>BR7.0 or BTSM SW=BR7.0
and BTS load>=48, EADVCMPDCMHO attribute cannot
assume NULL value.
If the superordinate BTSM SW<BR7.0 or BTSM SW=BR7.0
and BTS load<48, EADVCMPDCMHO attribute must assume
NULL value.


576 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
If the superordinate BTSM SW>BR7.0 or BTSM SW=BR7.0
and BTS load>=48, HOTHCMPLVDL attribute cannot assume
NULL value.
If the superordinate BTSM SW<BR7.0 or BTSM SW=BR7.0
and BTS load<48, HOTHCMPLVDL attribute must assume
NULL value.
If the superordinate BTSM SW>BR7.0 or BTSM SW=BR7.0
and BTS load>=48, HOTHCMPLVUL attribute cannot assume
NULL value.
If the superordinate BTSM SW<BR7.0 or BTSM SW=BR7.0
and BTS load<48, HOTHCMPLVUL attribute must assume
NULL value.
If the superordinate BTSM SW>BR7.0 or BTSM SW=BR7.0
and BTS load>=48, HOTHDCMLVDL attribute cannot assume
NULL value.
If the superordinate BTSM SW<BR7.0 or BTSM SW=BR7.0
and BTS load<48, HOTHDCMLVDL attribute must assume
NULL value.
If the superordinate BTSM SW>BR7.0 or BTSM SW=BR7.0
and BTS load>=48, HOTHDCMLVUL attribute cannot assume
NULL value.
If the superordinate BTSM SW<BR7.0 or BTSM SW=BR7.0
and BTS load<48, HOTHDCMLVUL attribute must assume
NULL value.
The HOTHEFRCDL, HOTHEFRCUL, HOTHFRCDL, HOTHFR-
CUL, HOTHHRDDL, HOTHHRDUL, EADVCMPHOAMR, EAD-
VCMPHOSC, ADVCMPHOOAMR, HRDCMLIMTH attributes
must be set at NULL if the Software Version, running on the
superordinate BTSM object, is lower than BR8.0 release.
The ENAQUALEVHOM attribute cannot be set to TRUE if the
Software Version, running on the superordinate BTSM object, is
lower than BR8.0 release.
UNSUCCESSFUL_INVALID_ATTRIBUTES
For every SGXHOPAR, X = 7..10:
If SGXHOPAR is different from NULL value, it must be:
rateDowngradeDL <
SGXHOPAR.rateHOLowerThresholdQualDL
rateDowngradeUL <
SGXHOPAR.rateHOLowerThresholdQualUL.
For every SGXHOPAR, X = 1..14:
If SGXHOPAR is different from NULL value, it must be:
SGXHOPAR.HoRxlevDLinner < SGXHOPAR.HoRxlevD-
Louter.


A30808-X3247-M230-6-7619

577
CML:BSC HAND
Id:0900d805800d424e
Application Guidelines:
1. The following relationship must be satisfied between the value of the THORQST
timer and the value of the BSCT7 timer (see BSC object):
BSCT7 (BSC) < THORQST.
2. The NCELL parameter determines the maximum number of neighbour cells that can
be sent in the HO_COND_IND message from the BTS to the BSC. The MAXNCELL
parameter of the BSC object determines the maximum number of cells that can be
sent in the HANDOVER_REQUIRED message from BSC to MSC. Usually the value
of NCELL is greater than the value of MAXNCELL.
For every SGXHOPAR, X = 11..14:
If SGXHOPAR is different from NULL value, it must be:
SGXHOPAR.hoThresAMRComprDL <=
SGXHOPAR.hoThresAMRComprUL.
The EUBCHO attribute cannot be set at TRUE if the
FDDREPQTY attribute (see BTS object) is set at EC_N0.
The TRFHOE attribute cannot be set to TRUE in case of
Extended cell.
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The maximum number of different frequencies of adjacent cells
that can be included in System Information 5 is:
- 30, if LOTRACH=FALSE in HAND object and one or more
ADJC3Gs are equipped;
- 31, if LOTRACH=FALSE in HAND object and no ADJC3Gs
are equipped;
- 31, if LOTRACH=TRUE in HAND object and one or more
ADJC3Gs are equipped.
-32, otherwise.


578 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
3. When the inter cell handover is enabled (INTERCH/IERCHOSDCCH attribute) the
following attributes are relevant:
if none of the above flags is enabled no inter cell handover will be requested by the
BTS; otherwise the following attributes are relevant:
4. When the intra cell handover is enabled (INTRACH/IRACHOSDCCH attribute) the
following attributes are relevant:
5. When the handover due to bad uplink or downlink received quality is enabled
(RXQUALHO attribute) the following attributes are relevant:
enableDistanceHO HAND:DISTHO
enablePowerBudgetHO HAND:PBGTHO
enableRxQualHO HAND:RXQUALHO
enableRxLevHO HAND:RXLEVHO
enableFastUplinkHO HAND:EFULHO
nCell HAND:NCELL
timeHORequest HAND:THORQST
bcchFrequency BTS o TGTBTS:BCCHFREQ
bsIdentityCode BTS o TGTBTS:BSIC
cellGlobalIdentity BTS o TGTBTS:CELLGLID
msTxPwrMaxGsm BTS o TGTBTS:MSTXPMAXGSM
msTxPwrMaxPcs BTS o TGTBTS:MSTXPMAXPCS
msTxPwrMaxDcs BTS o TGTBTS:MSTXPMAXDCS
rxLevMinCell BTS o TGTBTS:RXLEVMIN
hoThresholdLevDLintra HAND:HOTDLINT
hoThresholdLevULintra HAND:HOTULINT
hoLowerThresholdQualDL HAND:HOLTHQUDL
hoLowerThresholdQualUL HAND:HOLTHQUUL
timerHORequest HAND:THORQST
hoAveragingLev HAND:HOAVLEV
hoAveragingQual HAND:HOAVQUAL
hoAveragingQual HAND:HOAVQUAL
hoLowerThresholdQualDL HAND:HOLTHQUDL
hoLowerThresholdQualUL HAND:HOLTHQUUL


A30808-X3247-M230-6-7619

579
CML:BSC HAND
Id:0900d805800d424e
6. When the handover due to uplink or downlink received low level is enabled
(RXLEVHO attribute) the following attributes are relevant:
7. When the handover due to the distance between MS and BTS is enabled (DISTHO
attribute) the following attributes are relevant:
Furthermore if the attribute EXTCHO - enableExtendedCellHO is set to TRUE, the
following attribute is relevant:
8. When the handover due to power budget is enabled (PBGTHO attribute) the follow-
ing attributes are relevant:
9. When the speed sensitive handover decision algorithm is enabled (DPBGTHO
attribute) the following attributes are relevant:
10. The value of the attribute HORXLVDLO must be greater than the value of the
attribute HORVLVDLI.
11. The value assigned to each field of colocatedCells must indicate a BTS already
equipped, cannot indicate the cell itself and the two fields of the attribute cannot
indicate the same cell.
12. When the intracell handover decision for the concentric cell handover is based both
on distance and rxlev (CCDIST = TRUE) the following attribute is relevant:
13. When the ranking of the target cells based on the priority layer is enabled (HIERC)
the following attributes are relevant:
hoAveragingLev HAND:HOAVLEV
hoLowerThresholdLevDL HAND:HOLOWTDL
hoLowerThresholdLevUL HAND:HOLOWTUL
hoAveragingDistance HAND:HOAVDIST
hoThresholdMsRangeMax HAND:HOTMSRM
hoThresholdMsRangeMaxExt HAND:HOTMSRME
hoAvPwrb HAND:HOAVPWRB
hoMargin ADJC:HOM
hoMarginDelayTime ADJC:HOMDTIME
hoMarginDynamicOffset ADJC:HOMDOFF
hoMarginStaticOffset ADJC:HOMSOFF
microcell ADJC:MICROCELL
hoConcentricCellDistance HAND:HOCCDIST
priorityLayer HAND:PL


580 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
14. When the excessive distance is enabled (attribute EEXCDIST of BTS object), the
value assigned to the attribute excessiveDistance (attribute EXCDIST of BTS
object) must be greater than the value assigned to the other Distance Handover
Thresholds:
hoThresholdMsRangeMax (attribute HOTMSRM of HAND object),
hoThresholdMsRangeMaxExt (attribute HOTMSRME of HAND object) in case of
extended cell.
15. If the attribute NOBAKHO (enableNobackHO) is set at TRUE, the following
attributes are relevant:
16. If the attribute NOFREPHO (enableNoFailrepHo) is set at TRUE, the following
attributes are relevant:
17. If the attribute ELIMITCH (enableLimitationIntraCellHo) is set at TRUE, the following
attributes are relevant:
Furthermore if the flag LOTRACH of HAND object is set at FALSE, the present
feature can be considered as virtually disabled due the fact that every Intracell
Handover will be managed via MSC.
18. The attribute TINOIERCHO should be set at a value greater than the TIMER T7 (see
BSC object) and Timer THORQST (see comand SET HAND).
19. The enableExtendedCellHo attribute can not be set at TRUE if the CELLTYPE
attribute of the BTS object is not set at EXTCELL.
20. The EXTCHO attribute can be set at the value TRUE if there are traffic channels set
in extended mode and also traffic channel set in not extended mode. Otherwise the
distance intracell handover in the extended cell is not possible.
21. If the attribute EXTCHO (enableExtendedCellHO) is set at TRUE, the following
attribute are relevant:
hierarchicalCellRankFlag HAND:HIERF
priorityLayerNCell ADJC:PLNC
penalityPriorityLayerNCell ADJC:PPLNC
levelOffsetNCell ADJC:LEVONC
timerInhibitBackHO ADJC:TINHBAKHO
maxFailHo HAND:MAXFAILHO
timerInhibitFailHO ADJC:TINHFAIHO
maxIntraCellHO HAND:MAIRACHO
timerNoIntraCellHO HAND:TINOIERCHO
hoMsTaMax HAND:HOMSTAM
hoMarginTa(Km) HAND:HOMRGTA
extendedMode CHAN:EXTMODE


A30808-X3247-M230-6-7619

581
CML:BSC HAND
Id:0900d805800d424e
22. The following conditions must be satisfied:
RateUpgradeDL < rateDowngradeDL < ratehoLowerThresholdQualDL
RateUpgradeUL < rateDowngradeUL < ratehoLowerThresholdQualUL.
23. When the fast uplink handover decision algorithm is enabled (EFULHO attribute) the
following attributes are relevant:
24. The trafficHighThreshold and trafficLowThreshold attributes must respect the follow-
ing relationship:
TRFHITH-TRFLTH >= 15.
25. The TRFMMA must be set at a value greater or equal to the value of TRFMS.
26. Due to the mapping averaged RXQUAL <-> C/I (see Tab. 6.15), the following
parameters should not exceed 20 dB or be less than 1 dB: HOLTHQAMRDL,
HOLTHQAMRUL, HOTHAMRCDL, HOTHAMRCUL, HOTHAMRDDL, HOTHAMR-
DUL. Any setting above 20 dB will not be rejected by the system, but the related
handover process will be affected consequently, as the related threshold will never
be reached.
27. In case of Satellites Link (Abis or Asub), Link Adaptation is blocked by the BTS. The
parameter AMRACMRDL is ignored as well as all Threshold and Hysteresis settings
in ACS. The Codec indicated in the ACS as Initial Codec Mode is used during the
whole connection. This is valid for all BTS types.
28. For every SGXHOPAR, X = 1..14: if at least one of the SGXHOPAR attribute fields
is set at a valid value, also all the other attribute fields must be set at a valid value.
Example of Command Execution:
Set HAND:NAME=HAND:0,INTERCH=TRUE,INTRACH=TRUE,
LOTERCH=FALSE,LOTRACH=FALSE,RXQUALHO=FALSE,RXLEVHO=FALSE,
DISTHO=FALSE,PBGTHO=TRUE,NCELL=10,THORQST=31,HOAVLEV=31-3,
HOAVQUAL=31-3,HOAVDIST=31,HOAVPWRB=31,HOLTHLVDL=63,HOTDLINT=63,
HOLTHLUUL=63,HOTULINT=63,HOLTHQUDL=7,HOLTHQUUL=7,HOTMSRM=15,
DPBGTHO=FALSE,HIERC=TRUE,PL=0,HIERF=Rank0,CCDIST=FALSE,
HORLVDLI=26,HORXLVDLO=32,HOCCDIST=5,ININHO=FALSE,
CCELL= not_defined-bts50,NOBAKHO=FALSE,NOFREPHO=FALSE,MAXFAILHO=4,
ELIMITCH=FALSE,MAIRACHO=10,TINOIERCHO=60,EXTCHO=FALSE,
HOTMSRME=100,HOMSTAM=32,HOMRGTA= 4, IERCHOSDCCH=TRUE,
IRACHOSDCCH=FALSE,ERUDGR=TRUE,TINHRUGR=50,
TINHRDGR=30,RAVEW=15,RUGRUL=2,RUGRDL=1,RDGRUL=5,RDGRDL=3,
RHOLTQUL=6,RHOLTQDL=4,EFULHO=FALSE,THLEVFULHO=0,ALEVFULHO=1-2,
TRFHOE=TRUE,TRFHOT=2,TRFKPRI=TRUE,TRFHITH=50,TRFLTH=,TRFMMA=2,
TRFMS=1,ELEVHOM=TRUE,AMRACMRDL=1,HOLTHQAMRDL=1,
averagedLevFastULHo HAND:ALEVFUHO
thresholdLevFuho HAND:THLEVFULHO
fastUplinkHandoverCell ADJC:FULHOC


582 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d424e
HAND
HOLTHQAMRUL=1,HOTHAMRCDL=2,HOTHAMRCUL=1,HOTHAMRDDL=4,
HOTHAMRDUL=1,EUHO=TRUE,EUBCHO=TRUE,EUSCHO=TRUE,
EUIMPHO=TRUE,SG1HOPAR=15-10-20-20-30-32-4-4,
SG2HOPAR=15-10-20-20-28-30-3-3,SG3HOPAR=15-10-20-20-25-30-3-3-18-18-18-
18,
SG4HOPAR=15-10-20-20-25-30-3-3-18-18-18-18,SG5HOPAR=10-8-20-20-25-30-3-
3-13-13,
SG6HOPAR=10-8-20-20-25-30-3-3-13-13,SG7HOPAR=10-8-20-20-25-30-3-3-4-4,
SG8HOPAR=10-5-20-20-25-30-3-3-4-4,SG9HOPAR=10-5-20-20-25-30-3-3-3-3,
SG10HOPAR=20-10-20-20-25-30-3-3-3-3,
SG11HOPAR=20-10-20-20-25-30-8-8-20-20,
SG12HOPAR=20-10-20-20-25-30-8-8-10-10,
SG13HOPAR=20-10-20-20-25-30-8-8-8-8,SG14HOPAR=20-10-20-20-25-30-8-8-8-8,
EADVCMPDCMHO=TRUE,HOTHCMPLVDL=40,HOTHCMPLVUL=40,
HOTHDMPLVDL=26,HOTHDMPLVUL=26, HOTHEFRCDL=18,HOTHEFR-
CUL=18,HOTHFRCDL=18,HOTHFRCUL=18,HOTHHRDDL=13,HOTHHR-
DUL=13,EADVCMPHOAMR=TRUE,EADVCMPHOSC=TRUE,ADVCMPHOOAMR=6,
HRDCMLIMTH=6, ENAQUALEVHOM=FALSE;


A30808-X3247-M230-6-7619

583
CML:BSC HDCTR
Id:0900d805800d565c
HDCTR
The HDCTR object provides the schedulation of the History on Dropped Calls tracing
activities within a BSS.
CREATE HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR CREATE HDCTR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the HDCTR object class.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
PERWEEK periodWeekly
MEASET measurementSets
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE HDCTR NAME=HDCTR:0..0 [,START=] [,STOP=] ,PERWEEK=
,MEASET=;
OBJECT_ALREADY_EQUIPPED
The instance of the HDCTR must not be already created in
order to perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The START and STOP attributes must be valid daily dates.
The STOP attribute must be set at a value greater or equal
to the value of START.
At least one day scheduled by the PERWEEK attribute must
be within START and STOP dates.


584 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d565c
HDCTR
Application Guidelines:
None
Example of Command Execution:
Create HDCTR:NAME=HDCTR:0, MEASET=8, START=12-Jun-2003, STOP=29-Sep-
2003,PERWEEK=weekly(sunday(period(9-00-13-00))-tuesday(period(15-00-16-30)));
DELETE HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR DELETE HDCTR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the HDCTR object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete HDCTR:NAME=HDCTR:0;
DELETE HDCTR NAME=HDCTR:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The HDCTR object must be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_STATUS
The HDCTR object must be in the LOCKED state to
perform the command.


A30808-X3247-M230-6-7619

585
CML:BSC HDCTR
Id:0900d805800d565c
GET HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR GET HDCTR
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the HDCTR
object class.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
PERWEEK periodWeekly
MEASET measurementSets
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get HDCTR:NAME=HDCTR:0,REQATTL=MEASET&START&STOP&PERWEEK;
GET HDCTR NAME=HDCTR:0..0 [,REQATTL= START ,STOP
,PERWEEK ,MEASET];
START: startDate
STOP: stopDate
PERWEEK: periodWeekly
MEASET: measurementSets
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


586 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d565c
HDCTR
GET HDCTR BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR GET HDCTR BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the HDCTR
object class.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
PERWEEK periodWeekly
MEASET measurementSets
System Responses:
See GET HDCTR
Application Guidelines:
See GET HDCTR
Example of Command Execution:
See GET HDCTR
GET HDCTR STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR GET HDCTR STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
HDCTR object:
GET HDCTR BASICS NAME=HDCTR:0..0;
GET HDCTR STAT NAME=HDCTR:0..0;


A30808-X3247-M230-6-7619

587
CML:BSC HDCTR
Id:0900d805800d565c
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get HDCTR STAT:NAME=HDCTR:0;
GETINFO HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR GETINFO HDCTR
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides the whole set of information in order to retrieve an overview
about the HDCTR (History Dropped Call Trace) activity:
1. The report complete indication.
2. The states of the HDCTR: AST, OST, availability Off Duty (SET/RESET).
3. The maximum number of valid history measurement sets to be collected and
recorded at BTS before calls drops.
4. The ELAPSED TYPE (TRUE/FALSE).
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO HDCTR NAME=HDCTR:0..0;


588 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d565c
HDCTR
5. The start time of HDCTR trace.
6. The current file size (Kbyte) of HDCTR file.
7. The maximum file size (Mbyte) of HDCTR file size.
8. The upload period.
9. The total number of BTS monitored.
10. The list of all BTS traced by HDCTR.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO HDCTR ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT HDCTR:
NAME = HDCTR:0
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
MEAS SETS: 4
ELAPSED TYPE: TRUE
START TIME: 31:Mar:2000 14:44:00
CURRENT FILE SIZE: 3145 KBYTES
MAX HDCTR FILE SIZE: 5 MBYTES
UPLOAD PERIOD: 2
TOT NBT BTS MONITORED: 40
LIST OF BTS TRACED:
BTSM: BTS:
0 1
2 1
0 2
...
200 13


A30808-X3247-M230-6-7619

589
CML:BSC HDCTR
Id:0900d805800d565c
0 4
20 5
END OF REPORT
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo HDCTR:NAME=HDCTR:0;
LOCK HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR LOCK HDCTR
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
LOCK HDCTR NAME=HDCTR:0..0;


590 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d565c
HDCTR
NACK CAUSES:
Application Guidelines:
The administrative state Locked will survive at the Full Init (and consequently to the load
database).
Example of Command Execution:
Lock HDCTR:NAME=HDCTR:0;
SET HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR SET HDCTR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the HDCTR object class.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
PERWEEK periodWeekly
MEASET measurementSets
System Responses:
- Operation Completed
Successful
- Operation Failed
ALREADY_IN_TARGET_STATE
The selected object is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state.
SET HDCTR NAME=HDCTR:0..0 [,START=] [,STOP=] [,PERWEEK=]
[,MEASET=];


A30808-X3247-M230-6-7619

591
CML:BSC HDCTR
Id:0900d805800d565c
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set HDCTR:NAME=HDCTR:0, MEASET=8, START=12-Jun-2003, STOP=29-Sep-
2003,PERWEEK=weekly(sunday(period(9-00-13-00))-tuesday(period(15-00-16-30)));
UNLOCK HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR UNLOCK HDCTR
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
The START and STOP attributes must be valid daily dates.
The STOP attribute must be set at a value greater or equal
to the value of START.
At least one day scheduled by the PERWEEK attribute must
be within START and STOP dates.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance
is in LOCKED state.
UNLOCK HDCTR NAME=HDCTR:0..0;


592 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d565c
HDCTR
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock HDCTR:NAME=HDCTR:0;
UPLHDCTR HDCTR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL HDCTR UPLHDCTR HDCTR
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command allows to upload a HDCTR file.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OWR overWrite
System Responses:
- Operation Completed
The LMT notifies the successful completion of the procedure.
- Operation Failed
NACK CAUSES:
File Not Found
Message Out Of Sequence
Aborted By User
Time Out Expired
Aborted By Network Element
Internal SW Error
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.
UPLHDCTR HDCTR NAME=HDCTR:0..0 ,DESTDIR= ,OWR=;


A30808-X3247-M230-6-7619

593
CML:BSC HDCTR
Id:0900d805800d565c
Segment Out Of Sequence
Last Segment Expected
Disk Access Error
Disk Write Error
Disk Error
File Already Exists
Application Guidelines:
None
Example of Command Execution:
UplHDCTR HDCTR:NAME=HDCTR:0,DESTDIR=D:\Siemens\Hdctrlogdir,
OWR=YES;


594 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4254
IPLI
IPLI
The IPLI functional object represents the IP link used for the communication between
the BSC and external network elements (Radio Commander and Cell Broadcast
Center).
CREATE IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI CREATE IPLI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the IPLI object class. The IPLI object instance
must be created with the following features:
only one instance of the IPLI object can be created;
no mixed configurations are allowed: it is possible to create either a X25A/D link or
the IPLI one.
After having created the IPLI object instance the user can configure the links to RC/CBC
applications, creating OMAL and CBCL object instances.
It is important to specify both the GATEWAY values.
Long Names:
NAME Addres of the managed object
PRIMARYIPADDR primaryIpAddress
SECONDARYIPADDR secondaryIpAddress
GATEWAY0 gateway0
GATEWAY1 gateway1
SUBNETMASK subnetMask
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE IPLI NAME=IPLI:0..0 ,PRIMARYIPADDR= ,SECONDARYI-
PADDR= [,GATEWAY0=] [,GATEWAY1=] ,SUBNET-
MASK=;
UNSUCCESFUL_ OBJECT_ALREADY_EQUIPPED


A30808-X3247-M230-6-7619

595
CML:BSC IPLI
Id:0900d805800d4254
Application Guidelines:
None.
Example of Command Execution:
Case 1: MPCC0 and MPCC1 stay on different subnets
Create IPLI:NAME=IPLI:0, GATEWAY0 = 172.31.21.1, PRIMARYIPADDR =
172.31.21.100, GATEWAY1 = 172.31.51.1, SECONDARYIPADDR =172.31.21.125,
SUBNETMASK=255.255.255.0;
Case 2: MPCC0 and MPCC1 stay on the same subnet (GATEWAY0=GATEWAY1)
Create IPLI:NAME=IPLI:0, GATEWAY0 = 172.31.21.1, PRIMARYIPADDR =
172.31.21.100, GATEWAY1 = 172.31.21.1, SECONDARYIPADDR =172.31.21.125,
SUBNETMASK=255.255.255.0;
Case 3: MPCC0, MPCC1 and RC/CBC stay on the same subnet (GATEWAY0=NULL,
GATEWAY1=NULL)
Create IPLI:NAME=IPLI:0, GATEWAY0 = NULL, PRIMARYIPADDR = 172.31.21.100,
GATEWAY1 = NULL, SECONDARYIPADDR =172.31.21.125, SUBNET-
MASK=255.255.255.0;
DELETE IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI DELETE IPLI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the previously created instance of the IPLI object class. The IPLI
object cannot be deleted if either the OMAL object or the CBCL object are still equipped.
The instance of the object must not be already created in order to
perform the command.
INVALID_COMMAND
No mixed configurations are possible, that is, if a X25A or a X25D
object is already equipped, the CREATE IPLI command is refused.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The PRIMARYIPADDR has to be always different by SECOND-
ARYIPADDR.
DELETE IPLI NAME=IPLI:0..0;


596 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4254
IPLI
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete IPLI:NAME=IPLI:0;
GET IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GET IPLI
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of the instance of the IPLI object
class.
Long Names:
NAME Addres of the managed object
PRIMARYIPADDR primaryIpAddress
SECONDARYIPADDR secondaryIpAddress
GATEWAY0 gateway0
GATEWAY1 gateway1
SUBNETMASK subnetMask
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The IPLI object cannot be deleted if either the OMAL object or the
CBCL object or both are equipped.
GET IPLI NAME=IPLI:0..0 [,REQATTL= PRIMARYIPADDR ,SEC-
ONDARYIPADDR ,GATEWAY0 ,GATEWAY1 ,SUBNET-
MASK];


A30808-X3247-M230-6-7619

597
CML:BSC IPLI
Id:0900d805800d4254
System Responses:
- Operation Completed
GET IPLI BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET IPLI BASICS
None.
Example of Command Execution:
Get IPLI:NAME=IPLI:0,REQATTL=PRIMARYIPADDR&
SECONDARYIPADDR&GATEWAY0&GATEWAY1&SUBNETMASK;
GET IPLI BASICS
Get IPLI BASICS:NAME=IPLI:0;
NAME: name
PRIMARYIPADDR: PrimaryIpAddress
SECONDARYI-
PADDR:
SecondaryIpAddress
GATEWAY0: gateway0
GATEWAY1: gateway1
SUBNETMASK: SubnetMask
NAME: name
PRIMARYIPADDR: PrimaryIpAddress
SECONDARYI-
PADDR:
SecondaryIpAddress
GATEWAY0: Gateway0
GATEWAY1: Gateway1
SUBNETMASK: SubnetMask
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


598 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4254
IPLI
GET IPLI BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GET IPLI BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of the instance of the IPLI object
class.
Long Names:
NAME Addres of the managed object
PRIMARYIPADDR primaryIpAddress
SECONDARYIPADDR secondaryIpAddress
GATEWAY0 gateway0
GATEWAY1 gateway1
SUBNETMASK subnetMask
System Responses:
See GET IPLI
Application Guidelines:
See GET IPLI
Example of Command Execution:
See GET IPLI
GET IPLI STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GET IPLI STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the IPLI
object:
GET IPLI BASICS NAME=IPLI:0..0;
GET IPLI STAT NAME=IPLI:0..0;


A30808-X3247-M230-6-7619

599
CML:BSC IPLI
Id:0900d805800d4254
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get IPLI STAT:NAME=IPLI:0;
GETINFO IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GETINFO IPLI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. IP Connection: it's the MPCC copy that supports the active IP connection.
2. IP Operational State.
3. IP Availability Status.
4. IP Primary Address: it's the IP address assigned to the Providing Service MPCC
card (the RC uses this address to transmit with the BSC).
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO IPLI NAME=IPLI:0..0;


600 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4254
IPLI
5. IP Second Address: it's the IP address assigned to the Standby MPCC card (never
used by RC except for the RC-BSC IP link test).
6. IP NetMask Address: it's the local LAN address.
7. IP Gateway 0 Address: it's the IP address of the default gateway connected to the
MPCC copy 0 ( used when RC/CBC doesn't belong to tha same IP sub-network of
the BSC).
8. IP Gateway 1 Address: it's the IP address of the default gateway connected to the
MPCC copy 1 ( used when RC/CBC doesn't belong to tha same IP sub-network of
the BSC).
9. OMAL Number: it's the copy of OMAL.
10. OMAL Operational State.
11. OMAL Availability Status.
12. OMAL Standby Status.
13. Service Type: possible values are FTAM or CMIP.
14. Ftam Connection number.
15. CBCL Number: it's the copy of OMAL.
16. CBCL Administrative State.
17. CBCL Operational State.
18. CBCL Availability Status.
19. CBCL Standby Status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO IPLI ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT IPLI:
NAME = IPLI:0
IP CONNECTION: MPCC_0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
IP PRIMARY ADDRESS: 123:123:123:123
IP SECONDARY ADDRESS: 124:124:124:4
NETMASK ADDRESS: 255:0:0:0
GATEWAY 0 ADDRESS: 34:56:78:123
GATEWAY 1 ADDRESS: 37:456:123:9


A30808-X3247-M230-6-7619

601
CML:BSC IPLI
Id:0900d805800d4254
OMAL 0:
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
SERVICE TYPE: FTAM
FTAM CONNECTION: 1
CBCL 1:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
END OF REPORT
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo IPLI:NAME=IPLI:0;
GETRELATIONSHIP IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI GETRELATIONSHIP IPLI
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
IPLI
NAME=IPLI:0..0;


602 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4254
IPLI
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship IPLI:NAME=IPLI:0;
PING IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI PING IPLI
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The PING IPLI command is used in order to allow the operator to test in an easy way
the configuration of the BSC IP host.
This command is especially useful during the IPLI configuration phase when the
operator is in charge of configuring the IPLI attributes according to the LAN topology,
the BSC belongs to. This command allows the operator to ping, from the BSC (from
either MPCC:0 or MPCC:1), a generic IP address, in order to check the correctness of
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PING IPLI NAME=IPLI:0..0 ,MPCCCOPY= ,IPADDR=;


A30808-X3247-M230-6-7619

603
CML:BSC IPLI
Id:0900d805800d4254
all the IPLI attribute values. It must be noted, however, that the result of this test is only
useful for the operator, but it will never draw to IPLI state and status change.
Long Names:
NAME Addres of the managed object
MPCCCOPY mpccCopy
IPADDR ipAddress
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Ping IPLI:NAME=IPLI:0;
SET IPLI
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The MPCC card not providing service must be unlocked/hot
standby
UNSUCCESSFUL_COMMAND_REJECTED
There is a test already in progress on same MPCCCOPY (not
explicity requested from operator).
UNSUCCESSFUL_COMMAND_ALREADY_IN_PROGRESS
The operator has already requested a ping test on same
MPCCCOPY and previous command has not finished.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The IP address is not syntactly correct; the convention used for his
value is the well-known dotted decimal format
(e.g."172.31.21.88").
The IP address must not be a broadcast address (e.g. "
xxx.xxx.xxx.255").
SET IPLI NAME=IPLI:0..0 [,PRIMARYIPADDR=] [,SECONDARYI-
PADDR=] [,GATEWAY0=] [,GATEWAY1=] [,SUBNET-
MASK=];


604 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4254
IPLI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL IPLI SET IPLI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the IPLI object class. No lock proce-
dure is foreseen for changing IPLI attributes.
Long Names:
NAME Addres of the managed object
PRIMARYIPADDR primaryIpAddress
SECONDARYIPADDR secondaryIpAddress
GATEWAY0 gateway0
GATEWAY1 gateway1
SUBNETMASK subnetMask
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set IPLI:NAME=IPLI:0,PRIMARYIPADDR=172.31.21.88,
SECONDARYIPADDR=172.31.21.90, GATEWAY0=<NULL>, GATEWAY1=<NULL>,
SUBNETMASK=255.255.255.0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The PRIMARYIPADDR has to be always different by
SECONDARYIPADDR.


A30808-X3247-M230-6-7619

605
CML:BSC IXLT
Id:0900d805800d4257
IXLT
The IXLT object represents the Q3 interface module with the RC and X.25 local terminal.
GET IXLT STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GET IXLT STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the IXLT
object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
1. Only sets with raised bits are shown.
2. Explanation of the meaning of IXLT status:
The handling of the status attributes may be summarized as follows:
GET IXLT STAT NAME=IXLT:0..1;
Value IXLT


606 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4257
IXLT
Example of Command Execution:
Get IXLT STAT:NAME=IXLT:0;
GETINFO IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GETINFO IXLT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The "RSU running" object and the "RSU version".
2. The states and statuses of the IXLT: AST, OST, AVS, CST, STNDBYST, PRS.
3. The software working mode (SWST), which can assume the following values:
UNDEFINED (when the card is disabled), FIRMWARE, SOFTWARE and LOADED.
4. The LMT link supported/not supported information.
5. The X25 is supported/not supported information.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO IXLT ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
standby PROVIDING SERVICE IXLT UNLOCKED and ENABLED config-
ured to support OMC and CBC link
HOT STANDBY not used
COLD STANDBY IXLT UNLOCKED and ENABLED and not
configured
NULL_STATUS IXLT LOCKED or DISABLED
availability FAILED IXLT faulted
DEGRADED if set, the IXLT is working in FW, else in SW
OFF_DUTY if set LMT is not active, else it is
DEPENDENCY PWRD is DISABLED or LOCKED
procedural INITIALIZING IXLT is being loaded
GETINFO IXLT NAME=IXLT:0..1;


A30808-X3247-M230-6-7619

607
CML:BSC IXLT
Id:0900d805800d4257
*** INFORMATION ***
GET INFO REPORT:
NAME = IXLT:0
RSU RUNNING: RSUEXE 4-5
RSU VERSION: 02-06-01-01-00-00_00-01-10
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: PROVIDING_SERVICE
PROCEDURAL STATUS: NONE
SOFTWARE WORKING MODE: SOFTWARE
LMT LINK SUPPORTED: YES
X25 LINK SUPPORTED: TRUE
END OF REPORT
Note:
1. In the manual the CONSISTENCY MAP field must be reserved for the developer.
2. The SERVICE TYPE field is abitString map where:0 = Undefined; bit 0 set = CMIP;
bit 1 set = FTAM.
- Operation Failed
GETINFO IXLT NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack IXLT:
name = IXLT:0
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


608 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4257
IXLT
Application Guidelines:
In the manual the CONSISTENCY MAP field must be reserved for the developer.
Example of Command Execution:
Getinfo IXLT:NAME=IXLT:0;
GETRELATIONSHIP IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GETRELATIONSHIP
IXLT
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.
For the IXLT object the OMAL and CBCL are the related FMOs.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
IXLT
NAME=IXLT:0..1;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

609
CML:BSC IXLT
Id:0900d805800d4257
Application Guidelines:
None.
Example of Command Execution:
Getrelationship IXLT:NAME=IXLT:0;
GETTEST IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT GETTEST IXLT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETTEST IXLT NAME=IXLT:0..1;
GETTEST IXLT:NAME=IXLT:0;
name = TEST:<n>
mOts = IXLT:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.


610 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4257
IXLT
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest IXLT:NAME=IXLT:0;
LOCK IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT LOCK IXLT
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
The command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
NO_SUCH_TEST
The test is not active.
LOCK IXLT NAME=IXLT:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
CRITICAL_ALARM_REJECTED
The command can be rejected due to high criticity of the
system state.


A30808-X3247-M230-6-7619

611
CML:BSC IXLT
Id:0900d805800d4257
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
3. It is emitted when the PLLH has become synchronized to an external source little
time ago, and the switch of the master PLLH (for LOCK or SWITCH command)
would leave the frequency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE.
The same can happen if less than 5 minutes have passed since last switch of NTW.
Example of Command Execution:
Lock IXLT:NAME=IXLT:0;
PERFTEST IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT PERFTEST IXLT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected DISK object; the test consists
of the following phases:
Accessibility Test (start phase),
Address Bus Test (WP1),
Alarm Register Test (WP2),
DUAM Test (WP3),
FW Internal Test (WP4),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST IXLT NAME=IXLT:0..1;
PERFTEST IXLT:NAME=IXLT:0;


612 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4257
IXLT
- Operation Failed
NACK CAUSES:
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
MOTS_NOT_LOCKED


A30808-X3247-M230-6-7619

613
CML:BSC IXLT
Id:0900d805800d4257
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest IXLT:NAME=IXLT:0;
STOPTEST IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT STOPTEST IXLT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
STOPTEST IXLT NAME=IXLT:0..1;
STOPTEST IXLT:NAME=IXLT:0;
testObject=TEST:<n>
Result TEST:


614 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4257
IXLT
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest IXLT:NAME=IXLT:0;
UNLOCK IXLT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE IXLT UNLOCK IXLT
Applicability:
Phase 2.
name = TEST:<n>
testOutcome = inconclusive
mOts = IXLT:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNLOCK IXLT NAME=IXLT:0..1;


A30808-X3247-M230-6-7619

615
CML:BSC IXLT
Id:0900d805800d4257
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. Unlocking of BTSM causes a full BTS alignment.
2. It is possible to unlock the IXLT card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock IXLT:NAME=IXLT:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


616 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
LICD
The LICD object is the interface card for 4 or 12 PCM lines (depending on whether it is
implemented by means of a QTLP or a STLP respectively) at 2Mbit/s or 1.544 Mbit/s.
The redundancy for this card is provided by the LICDS card and is a N+1 type of
redundancy.
CREATE LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD CREATE LICD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a Line Interface Card (LICD) and sets the threshold values of the
system alarm for 2 Mbit/s lines.
Long Names:
NAME Addres of the managed object
ALARMT1 alarmTiming1
ALARMT2 alarmTiming2
ALARMT3 alarmTiming3
ALACOUNT alarmCounter
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE LICD NAME=LICD:0..9 [,ALARMT1=] [,ALARMT2=] [,ALARMT3=]
[,ALACOUNT=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The EPWR object instance must be already equipped in order to
submit the CREATE LICD command with instance > 1.
UNSUCCESSFUL_EXCEED_OBJECT_NBR


A30808-X3247-M230-6-7619

617
CML:BSC LICD
Id:0900d805800d425a
Application Guidelines:
1. A 2 Mbit/s line is put out of service (disabled) if a line alarm is found set at a period
longer than ALARMT2 or ALACOUNT time periods in the ALARMT3 time interval.
2. The line returns in service (enabled) if no alarms is found active for a subsequent
ALARMT1 time period.
3. After the creation of the object, the ADMINISTRATIVE state of this object is set at
UNLOCKED. The UNLOCK command is NOT required to put this object in service.
4. The timer ALARMT2 must be set shorter than TGUARD (see OPC object) - TSBS
(OPC object). Shorter values are useless and can cause a reset procedure at A-
interface also for very short link interruption due to the time needed to complete the
link realignment. For further information see application guidelines of SET OPC
command.
5. The timer ALARMT2 must be set shorter than TSYNC (see BTS object) and TTRAU
(BTS and TRAU objects). This is to avoid that, in case of PCM line alarm, the calls
are released before the alarm is detected.
6. The SBS detects a PCM link failure depending on the time specified by ALARMT2:
if ALARMT2 < 1 sec. and QTLP cards are configured then the detection time is
equal to ALARMT2 + 200 ms.
Example of Command Execution:
Create LICD:NAME=LICD:0,ALARMT1=200,ALARMT2=10,ALARMT3=1, ALA-
COUNT=32;
DELETE LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD DELETE LICD
Applicability:
Phase 2.
Visibility level: 2.
LICD instances greater than 8 are allowed only with NTWSNAP_STLP
network card.
UNSUCCESSFUL_CREATE__DELETE_IN_SEQUENCE
The LICD with lower instance number must be EQUIPPED in order to
submit the command.
When the LICD on the base module (instance 0,1 with the old rack; 0,
1, 2 with the new rack) is created, the LICDS-0 must be already
equipped.
When the LICD on the expansion module (instance > 1 with the old
rack; instance > 2 with the new rack) is created, the LICDS-1 must be
already equipped.
DELETE LICD NAME=LICD:0..9;


618 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
Command Description:
This command deletes a Line Interface Card (LICD) card previously created with the
command CREATE LICD.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete LICD:NAME=LICD:1;
GET LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GET LICD
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
There must be no pcm lines connected to that LICD
board in order to submit the DELETE LICD command.
UNSUCCESSFUL_CREATE__DELETE_IN_SEQUENCE
The LICDs with greater instance number must be in
NOT EQUIPPED state in order to submit the DELETE
LICD. Deletion of LICDs with greater instance number
must have been executed before.
UNSUCCESSFUL_IN_TEST
A diagnostic test is running on the LICD card.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a LICD, the relative object instance must
be in LOCKED state.
GET LICD NAME=LICD:0..9 [,REQATTL= ALARMT1 ,ALARMT2
,ALARMT3 ,ALACOUNT];


A30808-X3247-M230-6-7619

619
CML:BSC LICD
Id:0900d805800d425a
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the selected parameters of the Line Interface Card
(LICD) related to:
the LICD equipped status;
the system alarm threshold values for 2 Mbit/s lines.
Long Names:
NAME Addres of the managed object
ALARMT1 alarmTiming1
ALARMT2 alarmTiming2
ALARMT3 alarmTiming3
ALACOUNT alarmCounter
System Responses:
- Operation Completed
GET LICD BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
NAME: name
ALARMT1: alarmTiming1
ALARMT2: alarmTiming2
ALARMT3: alarmTiming3
ALACOUNT: alarmCounter
NAME: name
ALARMT1: alarmTiming1
ALARMT2: alarmTiming2
ALARMT3: alarmTiming3
ALACOUNT: alarmCounter
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


620 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
GET LICD BASICS
None.
Example of Command Execution:
Get LICD:NAME=LICD:0,REQATTL=ALARMT1&ALARMT2&ALARMT3&ALACOUNT;
GET LICD BASICS
Get LICD BASICS:NAME=LICD:0;
GET LICD BASICS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GET LICD BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the selected parameters of the Line Interface Card
(LICD) related to:
the LICD equipped status;
the system alarm threshold values for 2 Mbit/s lines.
Long Names:
NAME Addres of the managed object
ALARMT1 alarmTiming1
ALARMT2 alarmTiming2
ALARMT3 alarmTiming3
ALACOUNT alarmCounter
System Responses:
See GET LICD
Application Guidelines:
See GET LICD
Example of Command Execution:
See GET LICD
GET LICD BASICS NAME=LICD:0..9;


A30808-X3247-M230-6-7619

621
CML:BSC LICD
Id:0900d805800d425a
GET LICD STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GET LICD STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
LICD object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get LICD STAT:NAME=LICD:0;
GETINFO LICD
GET LICD STAT NAME=LICD:0..9;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO LICD NAME=LICD:0..9;


622 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETINFO LICD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the LICD: AST, OST, AVS, CST, STNDBYST, PRS.
2. The licd type.
3. The active NTW copy.
4. The incoming synchronization line, if any.
5. For each PCM line handled by the LICD the command will give the working mode of
the circuit (i.e. SINGLE_TRUNK, DOUBLE_TRUNK), the type (PCMB or PCMS),
the number, the used trunk (i.e. TRUNK_A, TRUNK_B, BOTH_TRUNK), the
administrative/operational states and the availability status.
6. For each PCM line handled the SS7, LAPD, L1CTRLST and X25A links, if any.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO LICD ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GETINFO REPORT LICD:
NAME = LICD:0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: NONE
PROCEDURAL STATUS: NONE
LICD TYPE: STLP
ACTIVE NTW COPY: 0
SYNC PCMC: 5


A30808-X3247-M230-6-7619

623
CML:BSC LICD
Id:0900d805800d425a
SYNC TRUNK: TRUNK_A
PCMC 0:
WORKING MODE: DOUBLE_TRUNK
PCMB 0:
USED TRUNK: TRUNK_A
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
SS7L TIMESLOT: 1 16 22
LPDL TIMESLOT: 2 18
L1CTRLST TIMESLOT: 18
X25A TIMESLOT: 13

PCMB 1:
USED TRUNK: TRUNK_B
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
SS7L TIMESLOT: 2 17 25
LPDL TIMESLOT: 1
L1CTRLST TIMESLOT: NONE
X25A TIMESLOT: 5

... ...
PCMC 5
WORKING MODE: DOUBLE_TRUNK
PCMB 5:
USED TRUNK: TRUNK_A
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
SS7L TIMESLOT: 2 13 20
LPDL TIMESLOT: 1 19
L1CTRLST TIMESLOT: 11
X25A TIMESLOT: 15

PCMB 8:


624 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
USED TRUNK: TRUNK_B
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
SS7L TIMESLOT: 5 14 24
LPDL TIMESLOT: 3
L1CTRLST TIMESLOT: NONE
X25A TIMESLOT: 10

END OF REPORT
- Operation Failed
GETINFO LICD NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack LICD:
name = LICD:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
The attribute SYNC describes the LICD circuit (0 - 3) and the trunk (A or B) carrying the
synchronism if there is one.
Example of Command Execution:
Getinfo LICD:NAME=LICD:0;
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

625
CML:BSC LICD
Id:0900d805800d425a
GETRELATIONSHIP LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETRELATIONSHIP
LICD
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.

For the LICD object the PCMB, BTSM, LPDLM, BTS, LPDLR, PCMS, TRAU, LPDLS,
PCMA and PCMG are the related FMOs.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship LICD:NAME=LICD:0;
GETRELATIONSHIP
LICD
NAME=LICD:0..9;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


626 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
GETSUBO LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETSUBO LICD
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo LICD:NAME=LICD:0;
GETTEST LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD GETTEST LICD
Applicability:
Phase 2.
Visibility level: 2.
GETSUBO LICD NAME=LICD:0..9;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETTEST LICD NAME=LICD:0..9;


A30808-X3247-M230-6-7619

627
CML:BSC LICD
Id:0900d805800d425a
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest LICD:NAME=LICD:0;
GETTEST LICD:NAME=LICD:0;
name = TEST:<n>
mOts = LICD:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


628 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
LOCK LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD LOCK LICD
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but , IXLT, PWRD,
TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock LICD:NAME=LICD:0;
PERFTEST LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD PERFTEST LICD
LOCK LICD NAME=LICD:0..9;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PERFTEST LICD NAME=LICD:0..9;


A30808-X3247-M230-6-7619

629
CML:BSC LICD
Id:0900d805800d425a
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected LICD object; the test consists
of the following phases:
Accessibility Test and Card Reset (start phase),
FW Protocol and Processor Test (WP1),
FW Self Test (WP2),
Check Alarm Status (WP3),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST LICD:NAME=LICD:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases


630 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest LICD:NAME=LICD:0;
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


A30808-X3247-M230-6-7619

631
CML:BSC LICD
Id:0900d805800d425a
SET LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD SET LICD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the threshold values of the system alarm for 2 Mbit/s lines.
Long Names:
NAME Addres of the managed object
ALARMT1 alarmTiming1
ALARMT2 alarmTiming2
ALARMT3 alarmTiming3
ALACOUNT alarmCounter
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. A 2 Mbit/s line is put out of service (disabled) if a line alarm is found set at a period
longer than ALARMT2 or ALACOUNT time periods in the ALARMT3 time interval.
2. The line returns in service (enabled) if no alarms is found active for a subsequent
ALARMT1 time period.
3. The timer ALARMT2 must be set shorter than TGUARD (see OPC object) - TSBS
(OPC object). Shorter values are useless and can cause a reset procedure at A-
interface also for very short link interruption due to the time needed to complete the
link realignment. For further information see application guidelines of SET OPC
command.
4. The timer ALARMT2 must be set shorter than TSYNC (see BTS object) and TTRAU
(BTS object). This is to avoid that, in case of PCM line alarm, the calls are released
before the alarm is detected.
SET LICD NAME=LICD:0..9 [,ALARMT1=] [,ALARMT2=] [,ALARMT3=]
[,ALACOUNT=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


632 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
5. The SBS detects a PCM link failure depending on the time specified by ALARMT2:
if ALARMT2 < 1 sec. and QTLP cards are configured then the detection time is equal
to ALARMT2 + 200 ms.
Example of Command Execution:
Set LICD:NAME=LICD:0,ALARMT1=2,ALARMT2=2,ALARMT3=5,ALACOUNT=2;
STOPTEST LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD STOPTEST LICD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
STOPTEST LICD NAME=LICD:0..9;
STOPTEST LICD:NAME=LICD:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = LICD:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases


A30808-X3247-M230-6-7619

633
CML:BSC LICD
Id:0900d805800d425a
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest LICD:NAME=LICD:0;
UNLOCK LICD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICD UNLOCK LICD
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNLOCK LICD NAME=LICD:0..9;


634 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425a
LICD
NACK CAUSES:
Application Guidelines:
It is possible to unlock the LICD card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock LICD:NAME=LICD:0,FPAR=FORCE;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

635
CML:BSC LICDS
Id:0900d805800d425d
LICDS
The LICDS object represents the spare LICD cards; two spare LICD cards (one for each
BSC frame) exist for the BSC.
CREATE LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS CREATE LICDS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a Line Interface Card Spare (LICDS).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
After the creation of the object LICDS its administrative state is set at UNLOCKED.
CREATE LICDS NAME=LICDS:0..1;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_CREATE__DELETE_IN_SEQUENCE
The LICDS with lower instance number must be EQUIPPED in
order to submit the CREATE LICDS command
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
If the network card is different from NTWSNAP_STLP the
additional Power Supply (EPWR) must be already created in
order to create LICDS-1.
UNSUCCESSFUL_WRONG_LICD_CARD
The LICDTYP attribute is not congruent with the NETWTYPE
previously assigned to the BSC via a SET BSC command.


636 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425d
LICDS
The UNLOCK command is NOT required to put the LICDS in service
Example of Command Execution:
Create LICDS:NAME=LICDS:0;
DELETE LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS DELETE LICDS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a Line Interface Card Spare (LICDS) previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
DELETE LICDS NAME=LICDS:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_CREATE_DELETE_IN_SEQUENCE
The LICDS with greater instance number must be in NOT
EQUIPPED state in order to submit the DELETE LICDS
command. Deletion of LICDS with greater instance number must
have been performed before.
The LICDS-1 can be deleted only if LICD cards of the expansion
module (with instance > 2 if the network card is
NTWSNAP_STLP, with instance > 1 otherwise) are in NOT
EQUIPPED state.
The LICDS-0 can be deleted only if LICD cards of the base
module (with instance < 3 if the network card is
NTWSNAP_STLP, with instance < 2 otherwise) are in NOT
EQUIPPED state.
UNSUCCESSFUL_IN_TEST
A diagnostic test is running on the LICDS card.


A30808-X3247-M230-6-7619

637
CML:BSC LICDS
Id:0900d805800d425d
Application Guidelines:
None.
Example of Command Execution:
Delete LICDS:NAME=LICDS:0;
GET LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GET LICDS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the Line Interface Card Spare (LICDS) equipped
status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get LICDS:NAME=LICDS:0;
UNSUCCESSFUL_INVALID_STATUS
Before deleting a LICDS, the relative object instance must be in
LOCKED state.
GET LICDS NAME=LICDS:0..1;
NAME: name
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


638 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425d
LICDS
GET LICDS STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GET LICDS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
LICDS object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get LICDS STAT:NAME=LICDS:0;
GET LICDS STAT NAME=LICDS:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

639
CML:BSC LICDS
Id:0900d805800d425d
GETRELATIONSHIP LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GETRELATIONSHIP
LICDS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.

For the LICDS object the PCMB, BTSM, LPDLM, BTS, LPDLR, PCMS, TRAU, LPDLS,
PCMA and PCMG are the related FMOs.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship LICDS:NAME=LICDS:0;
GETRELATIONSHIP
LICDS
NAME=LICDS:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


640 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425d
LICDS
GETSUBO LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GETSUBO LICDS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo LICDS:NAME=LICDS:0;
GETTEST LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS GETTEST LICDS
Applicability:
Phase 2.
Visibility level: 2.
GETSUBO LICDS NAME=LICDS:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETTEST LICDS NAME=LICDS:0..1;


A30808-X3247-M230-6-7619

641
CML:BSC LICDS
Id:0900d805800d425d
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest LICDS:NAME=LICDS:0;
GETTEST LICDS:NAME=LICDS:0;
name = TEST:<n>
mOts = LICDS:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


642 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425d
LICDS
LOCK LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS LOCK LICDS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but , IXLT, PWRD,
TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock LICDS:NAME=LICDS;
PERFTEST LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS PERFTEST LICDS
LOCK LICDS NAME=LICDS:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PERFTEST LICDS NAME=LICDS:0..1;


A30808-X3247-M230-6-7619

643
CML:BSC LICDS
Id:0900d805800d425d
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected LICDS object; the test consists
of the following phases:
Accessibility Test and Card Reset (start phase),
FW Protocol and Processor Test (WP1),
FW Self Test (WP2),
Check Alarm Status (WP3),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST LICDS:NAME=LICDS:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases


644 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425d
LICDS
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest LICDS:NAME=LICDS:0;
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


A30808-X3247-M230-6-7619

645
CML:BSC LICDS
Id:0900d805800d425d
STOPTEST LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS STOPTEST LICDS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
STOPTEST LICDS NAME=LICDS:0..1;
STOPTEST LICDS:NAME=LICDS:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = LICDS:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase. phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =


646 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d425d
LICDS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest LICDS:NAME=LICDS:0;
UNLOCK LICDS
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE LICDS UNLOCK LICDS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNLOCK LICDS NAME=LICDS:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

647
CML:BSC LICDS
Id:0900d805800d425d
Application Guidelines:
It is possible to unlock the LICD card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock LICDS:NAME=LICDS:0;
The object instance must be already equipped.


648 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4261
LMT-INTERNAL
LMT-INTERNAL
The LMT-INTERNAL object represents the Local Maintenance Terminal.
ECHO LMT-INTERNAL
Command Tree:
MANAGED-ELEMENT LMT-INTERNAL ECHO LMT-INTERNAL
Applicability:
.
Visibility level: 0.
Command Description:
This command prompts a free string on the user interface.
Long Names:
NAME Addres of the managed object
TEXT text
System Responses:
- Operation Completed
None.
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
ECHO:TEXT="The Script has performed all SET commands"
EXEC LMT-INTERNAL
Command Tree:
MANAGED-ELEMENT LMT-INTERNAL EXEC LMT-INTERNAL
Applicability:
.
Visibility level: 0.
ECHO LMT-INTERNAL NAME=LMT-INTERNAL:0..0 ,TEXT=;
EXEC LMT-INTERNAL NAME=LMT-INTERNAL:0..0 ,FILENAME= [,ABORT=]
[,DANGEROUS=] [,ERROR=] [,PRIORITY=] [,SYNCHRO=];


A30808-X3247-M230-6-7619

649
CML:BSC LMT-INTERNAL
Id:0900d805800d4261
Command Description:
This command starts a script execution.
Long Names:
NAME Addres of the managed object
FILENAME fileName
ABORT abort
DANGEROUS dangerous
ERROR error
PRIORITY priority
SYNCHRO synchro
System Responses:
- Operation Completed
None.
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
EXEC:FILENAME="C:\MYSCRIPT.LMT",SYNCHRO=YES;
SET LMT-INTERNAL
Command Tree:
MANAGED-ELEMENT LMT-INTERNAL SET LMT-INTERNAL
Applicability:
.
Visibility level: 0.
Command Description:
This command configures the CLI System settings.
Long Names:
NAME Addres of the managed object
ABORT abort
OUTPUT output
CLEAR clear
SYNCHRO synchro
SET LMT-INTERNAL NAME=LMT-INTERNAL:0..0 [,ABORT=] [,OUTPUT=]
[,CLEAR=] [,SYNCHRO=] [,PRIORITY=];


650 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4261
LMT-INTERNAL
PRIORITY priority
System Responses:
- Operation Completed
None.
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
SET:ABORT=YES,PRIORITY=0;


A30808-X3247-M230-6-7619

651
CML:BSC LPDLM
Id:0900d805800d4264
LPDLM
The LPDLM object identifies the logical link used by the BTSE to communicate with the
BSC for operation and maintenance purposes.
CREATE LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM CREATE LPDLM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a logical LapD connection on a signalling link on Abis interface.
It reserves a PCM timeslot for the Abis signalling of the associated BTSM. If optional
submultiplexing is used, a LPDLM is associated with a subslot within the slot.
Long Names:
NAME Addres of the managed object
ABISCH abisChannel
LAPDPOOL lapdPool
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE LPDLM NAME=BTSM:0..199/LPDLM:0..10 ,ABISCH= [,LAPD-
POOL=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command..
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The PCMB object instance inserted in the ABISCH attribute
must be already equipped.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The timeslot or subslot inserted in the CREATE LPDLM
command must be available (neither allocated by other links
nor configurated as SUBTSLB object).
UNSUCCESSFUL_INVALID_TIME_SLOT


652 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4264
LPDLM
Application Guidelines:
Before configuring a new LPDLM on the BSC side it is necessary to configure the
corresponding LPDLE object of the connected BTSE equipment, otherwise the Abis
Alignment is going to fail.
Example of Command Execution:
Create LPDLM:NAME=BTSM:0/LPDLM:0,ABISCH=19-19-3,LAPDPOOL=1;
DELETE LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM DELETE LPDLM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an LPDLM instance previously created.
Long Names:
NAME Addres of the managed object
The value assigned to the timeSlotNumber field of the
ABISCH is not compatible with the PCM line type attribute
(parameter PCMTYPE of BSC object).
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The BS-240XS supports up to 8 LPDLMs.
UNSUCCESSFUL_WRONG_PCMB_NUMBER
The PCMB choosen at LPDLM level must be consistent with
the PCMB line connected to the relative BTSM.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
No more than 8 LPDLM per BTSM can be created if the SW
of the superordinate BTSM is less than BR8.0.
Only if the superordinate BTSM is a BTS one up to 11 LPDLM
per BTSM can be equipped starting from BR8.0.
UNSUCCESSFUL_SUB_SLOT_ALREADY_ALLOCATED
If two PCMBs connected to the same port exist, it is not
possible to create two LPDLMs having the same address on
those PCMBs.
DELETE LPDLM NAME=BTSM:0..199/LPDLM:0..10;


A30808-X3247-M230-6-7619

653
CML:BSC LPDLM
Id:0900d805800d4264
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete LPDLM:NAME=BTSM:0/LPDLM:0;
GET LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GET LPDLM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters related to the LPDLM instance spec-
ified in the command.
Long Names:
NAME Addres of the managed object
ABISCH abisChannel
LAPDPOOL lapdPool
System Responses:
- Operation Completed
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
An LPDLM object instance cannot be deleted if an associated
SUBTSLB object instance exists.
GET LPDLM NAME=BTSM:0..199/LPDLM:0..10 [,REQATTL= ABISCH
,LAPDPOOL];
NAME: name


654 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4264
LPDLM
GET LPDLM BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET LPDLM BASICS
None.
Example of Command Execution:
Get LPDLM:NAME=BTSM:0/LPDLM:0,REQATTL=ABISCH&LAPDPOOL;
GET LPDLM BASICS
Get LPDLM BASICS:NAME=BTSM:0/LPDLM:0;
GET LPDLM BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GET LPDLM
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters related to the LPDLM instance spec-
ified in the command.
ABISCH: abisChannel
LAPDPOOL: lapdPool
NAME: name
ABISCH: abisChannel
LAPDPOOL: lapdPool
NOT_EQUIPPED
The object instance must be already equipped.
GET LPDLM BASICS NAME=BTSM:0..199/LPDLM:0..10;


A30808-X3247-M230-6-7619

655
CML:BSC LPDLM
Id:0900d805800d4264
Long Names:
NAME Addres of the managed object
ABISCH abisChannel
LAPDPOOL lapdPool
System Responses:
See GET LPDLM
Application Guidelines:
See GET LPDLM
Example of Command Execution:
See GET LPDLM
GET LPDLM STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GET LPDLM STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
LPDLM object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
GET LPDLM STAT NAME=BTSM:0..199/LPDLM:0..10;


656 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4264
LPDLM
NACK CAUSES:
Application Guidelines:
1. TSYNC should be equal to TTRAU parameter.
2. Only sets with raised bits are shown.
Example of Command Execution:
Get LPDLM STAT:NAME=BTSM:0/LPDLM:0;
GETINFO LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GETINFO LPDLM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the LPDLM: OST, AVS, STNDBYST
2. The LPDLM absolute number
3. The TEI number related to the LPDLM
4. The baud rate of the physical lapd
5. The states and statuses of the PPXL (AST, OST, AVS, CST and PRS) which
handles the LPDLM
6. The PPXL HDLC circuit and PPXL timeslot
7. The identity of the subslot on Abis interface
8. The sample pattern transmitted and received by the PPXL on the LAPD
9. The sample pattern received and transmitted by the BSC on the PCM line
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO LPDLM ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO LPDLM NAME=BTSM:0..199/LPDLM:0..10;


A30808-X3247-M230-6-7619

657
CML:BSC LPDLM
Id:0900d805800d4264
*** INFORMATION ***
GETINFO REPORT LPDLM:
NAME = LPDLM:0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: HOT_STANDBY
LPDL ABSOLUTE NR: 5
TEI: 30
BAUD RATE: RATE16KB
LAPD POOL: 1
SERVING PPXL 1:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
PPXL HDLC CIRCUIT: 1
PPXL TIMESLOT: 80 - 3 (TS NR - SUBTS NR)
ABIS TIMESLOT: 30 - 1 - 0 (PCM NR - TS NR - SUBTS NR)
PPXX TX SAMPLE: 0x02
PPXX RX SAMPLE: 0x03
PCMB TX SAMPLE: 0x02
PCMB RX SAMPLE: 0x03
END OF REPORT
- Operation Failed
GETINFO LPDLM NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack LPDLM:
name = LPDLM:0


658 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4264
LPDLM
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo LPDLM:NAME=BTSM:0/LPDLM:0;
GETRELATIONSHIP LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GETRELATION-
SHIP LPDLM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the LPDLM object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW and PPXL.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
LPDLM
NAME=BTSM:0..199/LPDLM:0..10;


A30808-X3247-M230-6-7619

659
CML:BSC LPDLM
Id:0900d805800d4264
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship LPDLM:NAME=BTSM:0/LPDLM:0;
GETSUBO LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM GETSUBO LPDLM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO LPDLM NAME=BTSM:0..199/LPDLM:0..10;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


660 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4264
LPDLM
Application Guidelines:
None.
Example of Command Execution:
Getsubo LPDLM:NAME=BTSM:0/LPDLM:0;
SET LPDLM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM LPDLM SET LPDLM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the operator to modify the parameters related to a logical LapD
connection on a signalling link on Abis interface.
Long Names:
NAME Addres of the managed object
LAPDPOOL lapdPool
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set LPDLM:NAME=BTSM:0/LPDLM:0,LAPDPOOL=4;
SET LPDLM NAME=BTSM:0..199/LPDLM:0..10 [,LAPDPOOL=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

661
CML:BSC LPDLR
Id:0900d805800d4267
LPDLR
The LPDLR object represents the logical link used by a TRX to communicate with a BSC
for telecommunication purposes.
GET LPDLR STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR GET
LPDLR STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the BTS
object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. TSYNC should be equal to TTRAU parameter.
2. Only sets with raised bits are shown.
Example of Command Execution:
Get LPDLR STAT:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0;
GET LPDLR STAT NAME=BTSM:0..199/BTS:0..23/TRX:0..23/LPDLR:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


662 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4267
LPDLR
GETINFO LPDLR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR
GETINFO LPDLR
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the LPDLR:OST, AVS.
2. The LPDLR absolute number.
3. The TEI number related to the LPDLR.
4. The Primary and the Current position of the LPDLM associated.
5. The baud rate of the physical lapd.
6. The Lapd pool number.
7. The states and statuses of the PPXL (AST, OST, AVS, CST and PRS) which
handles the LPDLR.
8. The PPXL HDLC circuit and PPXL timeslot.
9. The identity of the subslot on Abis interface.
( I ) If the LPDLM associated to the LPDLR is out of service, the following information is
not shown in the Getinfo LPDLR command response:
- lpdlm current position;
- baud rate;
- lapd pool number;
- abis timeslot (pcmline, tslt, subslot)
- serving PPXL timeslot and serving PPXL subtimeslot;
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO LPDLR ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:42:35 20/01/1992
*** INFORMATION ***
GET INFO REPORT LPDLR:0
NAME = LPDLR:0
GETINFO LPDLR NAME=BTSM:0..199/BTS:0..23/TRX:0..23/LPDLR:0..0;


A30808-X3247-M230-6-7619

663
CML:BSC LPDLR
Id:0900d805800d4267
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
LPDL ABSOLUTE NR: 12
TEI: 2
LPDLM PRIMARY POSITION: 0
LPDLM CURRENT POSITION: 0
BAUD RATE: RATE64KB
LAPD POOL: 0
SERVING PPXL 3:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
PPXL HDLC CIRCUIT: 1
PPXL TIMESLOT: 2
ABIS TIMESLOT: 30 - 21 (PCM NR - TS NR - SUBTS NR)
END OF REPORT
- Operation Failed
GETINFO LPDLR NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack LPDLR:
name = LPDLR:0
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.


664 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4267
LPDLR
Application Guidelines:
None.
Example of Command Execution:
Getinfo LPDLR:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0;
GETRELATIONSHIP LPDLR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR
GETRELATIONSHIP LPDLR
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the LPDLR object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW and PPXL.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
LPDLR
NAME=BTSM:0..199/BTS:0..23/TRX:0..23/LPDLR:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

665
CML:BSC LPDLR
Id:0900d805800d4267
Application Guidelines:
None.
Example of Command Execution:
Getrelationship LPDLR:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0;
GETSUBO LPDLR
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LPDLR
GETSUBO LPDLR
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo LPDLR:NAME=BTSM:0/BTS:0/TRX:0/LPDLR:0;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO LPDLR NAME=BTSM:0..199/BTS:0..23/TRX:0..23/LPDLR:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object must be created.


666 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426a
LPDLS
LPDLS
The LPDLS object identifies the logical link used by the TRAU to communicate with the
BSC for operation and maintenance purposes.
CREATE LPDLS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS CREATE LPDLS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a logical LAPD connection on a signalling link on Asub interface.
It reserves a PCM timeslot for the Asub signalling of the associated TRAU.
Long Names:
NAME Addres of the managed object
ASUBCH asubChannel
LAPDPOOL lapdPool
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
CREATE LPDLS NAME=TRAU:0..47/LPDLS:0..0 ,ASUBCH= [,LAPD-
POOL=];
Successful
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The PCMS object instance inserted in the ASUBCH attribute must
be already equipped.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The timeslot or subslot inserted in the create LPDLS command
must be not allocated by other links.
INVALID_ATTRIBUTE_VALUE


A30808-X3247-M230-6-7619

667
CML:BSC LPDLS
Id:0900d805800d426a
Application Guidelines:
None.
Example of Command Execution:
Create LPDLS:NAME=TRAU:0/LPDLS:0,ASUBCH=0-1-3,LAPDPOOL=2;
DELETE LPDLS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS DELETE LPDLS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an LPDLS instance previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Every PCMS can support only one LPDLS.
UNSUCCESSFUL_INVALID_TIME_SLOT
The value assigned to the timeSlotNumber field of the ASUBCH is
not compatible with the PCM line type attribute (parameter
PCMTYPE of BSC object).
16 Kbit LPDLS cannot be created on TSL 31, SSL 3.
16 Kbit LPDLS are supported by TRAU with SW >= BR8.0 and with
Load >=12.
DELETE LPDLS NAME=TRAU:0..47/LPDLS:0..0;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
No 2 Mbit PCM line on "A" interface has to be connected to
TRAU.


668 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426a
LPDLS
Application Guidelines:
None.
Example of Command Execution:
Delete LPDLS:NAME=TRAU:0/LPDLS:0;
GET LPDLS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GET LPDLS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters related to the LPDLS instance speci-
fied in the command.
Long Names:
NAME Addres of the managed object
ASUBCH asubChannel
LAPDPOOL lapdPool
System Responses:
- Operation Completed
GET LPDLS BASICS
- Operation Failed
NACK CAUSES:
GET LPDLS NAME=TRAU:0..47/LPDLS:0..0 [,REQATTL= ASUBCH
,LAPDPOOL];
NAME: name
ASUBCH: asubChannel
LAPDPOOL: lapdPool
NAME: name
ASUBCH: asubChannel
LAPDPOOL: lapdPool
NOT_EQUIPPED


A30808-X3247-M230-6-7619

669
CML:BSC LPDLS
Id:0900d805800d426a
Application Guidelines:
None.
GET LPDLS BASICS
None.
Example of Command Execution:
Get LPDLS:NAME=TRAU:0/LPDLS:0,REQATTL=ASUBCH&LAPDPOOL;
GET LPDLS BASICS
Get LPDLS BASICS:NAME=TRAU:0/LPDLS:0;
GET LPDLS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GET LPDLS
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters related to the LPDLS instance speci-
fied in the command.
Long Names:
NAME Addres of the managed object
ASUBCH asubChannel
LAPDPOOL lapdPool
System Responses:
See GET LPDLS
Application Guidelines:
See GET LPDLS
Example of Command Execution:
See GET LPDLS
The object instance must be already equipped
GET LPDLS BASICS NAME=TRAU:0..47/LPDLS:0..0;


670 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426a
LPDLS
GET LPDLS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GET LPDLS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
LPDLS object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get LPDLS STAT:NAME=TRAU:0/LPDLS:0;
GETINFO LPDLS
GET LPDLS STAT NAME=TRAU:0..47/LPDLS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO LPDLS NAME=TRAU:0..47/LPDLS:0..0;


A30808-X3247-M230-6-7619

671
CML:BSC LPDLS
Id:0900d805800d426a
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GETINFO LPDLS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the LPDLS: OST, AVS.
2. The LPDLS absolute number.
3. The TEI number related to the LPDLS.
4. The baud rate of the physical lapd.
5. The LAPD pool number.
6. The states and statuses of the PPXL (AST, OST, AVS, CST and PRS) which
handles the LPDLR.
7. The PPXL HDLC circuit and PPXL timeslot.
8. The identity of the subslot on Asub interface.
9. The sample pattern transmitted and received by the PPXL on the LAPD.
10. The sample pattern received and transmitted by the BSC on the PCM line.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO LPDLS ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT:
NAME = LPDLS:0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
LPDL ABSOLUTE NR: 1
TEI: 2
BAUD RATE: RATE64KB
LAPD POOL: 1


672 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426a
LPDLS
SERVING PPXL 1:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
PPXL HDLC CIRCUIT: 1
PPXL TIMESLOT: 0
ASUB TIMESLOT: 1 - 10 (PCM NR - TS NR - SUBTS NR)
PPXX TX SAMPLE: 0x02
PPXX RX SAMPLE: 0x03
PCMS TX SAMPLE: 0x02
PCMS RX SAMPLE: 0x03
END OF REPORT
- Operation Failed
GETINFO LPDLS NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack LPDLS:
name = LPDLS:0
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

673
CML:BSC LPDLS
Id:0900d805800d426a
Application Guidelines:
None.
Example of Command Execution:
Getinfo LPDLS:NAME=TRAU:0/LPDLS:0;
GETRELATIONSHIP LPDLS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GETRELATION-
SHIP LPDLS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the LPDLS object the related HMOs are the following: LICD/LICDS, EPWR, BSMS,
TPWR, PWRD, MPCC, TDPC, MEMT, NTW and PPXL.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship LPDLS:NAME=TRAU:0/LPDLS:0;
GETRELATIONSHIP
LPDLS
NAME=TRAU:0..47/LPDLS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


674 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426a
LPDLS
GETSUBO LPDLS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS GETSUBO LPDLS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo LPDLS:NAME=TRAU:0/LPDLS:0;
SET LPDLS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LPDLS SET LPDLS
Applicability:
Phase 2.
Visibility level: 2.
GETSUBO LPDLS NAME=TRAU:0..47/LPDLS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET LPDLS NAME=TRAU:0..47/LPDLS:0..0 [,LAPDPOOL=];


A30808-X3247-M230-6-7619

675
CML:BSC LPDLS
Id:0900d805800d426a
Command Description:
This command allows the operator to modify the parameters related to the logical LAPD
connection on a signalling link on Asub interface.
Long Names:
NAME Addres of the managed object
LAPDPOOL lapdPool
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set LPDLS:NAME=TRAU:0/LPDLS:0,LAPDPOOL=2;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in order to
perform the command.


676 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4680
MEL
MEL
The MEL (Managed Element) object represents the entry point of the addressing of the
BSS; it is used to distinguish different BSCs at the same Radio Commander.
GET MEL
Command Tree:
MANAGED-ELEMENT MEL GET MEL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the parameter values selected by means of the
REQATTL attribute.
Long Names:
NAME Addres of the managed object
MELID managedElementId
ETIME externalTime
VER version
System Responses:
- Operation Completed
GET MEL BASICS
- Operation Failed
NACK CAUSES:
GET MEL NAME=MEL:0..0 [,REQATTL= MELID ,ETIME ,VER];
NAME: name
MELID: managedElementId
ETIME: externalTime
VER: version
NAME: name
MELID: managedElementId
ETIME: externalTime
None.


A30808-X3247-M230-6-7619

677
CML:BSC MEL
Id:0900d805800d4680
Application Guidelines:
1. Using the LMT dashboard, when the PC time is modified, the NE time is also
modified and, when submitting the GET MEL command, the NE time is set back to
the original MEL time. This is the only way to correctly reset the NE time.
2. The LMT date range is narrower than BSC range: the LMT restriction on the date is
due to the win32 API that cannot support dates greater than 01/19/2038. For this
reason, if the user submits a date greater than 01/19/2038 by means of the ETIME
parameter of the SET MEL command and subsequently retrieves it (by means of a
GET MEL command) the date displayed in the ETIME parameter of the latter
command will be different.
GET MEL BASICS
None.
Example of Command Execution:
Get MEL:NAME=MEL:0,REQATTL=MELID&ETIME&VER;
GET MEL BASICS
Get MEL BASICS:NAME=MEL:0;
GET MEL
Command Tree:
MANAGED-ELEMENT MEL GET MEL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the parameter values selected by means of the
REQATTL attribute.
Long Names:
NAME Addres of the managed object
MELID managedElementId
VER version
System Responses:
See GET MEL
Application Guidelines:
See GET MEL
GET MEL NAME=MEL:0..0;


678 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4680
MEL
Example of Command Execution:
See GET MEL
GET MEL BASICS
Command Tree:
MANAGED-ELEMENT MEL GET MEL BASICS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the parameter values selected by means of the
REQATTL attribute.
Long Names:
NAME Addres of the managed object
ETIME externalTime
System Responses:
See GET MEL
Application Guidelines:
See GET MEL
Example of Command Execution:
See GET MEL
SET MEL
Command Tree:
MANAGED-ELEMENT MEL SET MEL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
Long Names:
NAME Addres of the managed object
GET MEL BASICS NAME=MEL:0..0;
SET MEL NAME=MEL:0..0 [,MELID=] [,ETIME=];


A30808-X3247-M230-6-7619

679
CML:BSC MEL
Id:0900d805800d4680
MELID managedElementId
ETIME externalTime
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
1. All the sub-fields of the ETIME parameter must be set by the operator.
2. The LMT date range is narrower than BSC range: the LMT restriction on the date is
due to the win32 API that cannot support dates greater than 01/19/2038. For this
reason, if the user submits a date greater than 01/19/2038 by means of the ETIME
parameter of the SET MEL command and subsequently retrieves it (by means of a
GET MEL command) the date displayed in the ETIME parameter of the latter
command will be different.
3. If MELID parameter is changed, it is necessary to save and reload the DataBase
from the disk or to perform a BSC Bring-up.
Example of Command Execution:
Set MEL:NAME=MEL:0,MELID=15,ETIME=1-55-00-2-2-2002;


680 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426d
MEMT
MEMT
The MEMT object contains a 2 Mbyte RAM memory bank with direct addressing; it has
redundancy of the active/standby type and each copy can be attained by both copies of
TDPC.
GET MEMT STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GET MEMT STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
MEMT object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get MEMT STAT:NAME=MEMT:0;
GET MEMT STAT NAME=MEMT:0..1;


A30808-X3247-M230-6-7619

681
CML:BSC MEMT
Id:0900d805800d426d
GETRELATIONSHIP MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GETRELATIONSHIP
MEMT
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.

For the MEMT object the MEL is the related FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship MEMT:NAME=MEMT:0;
GETSUBO MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GETSUBO MEMT
GETRELATIONSHIP
MEMT
NAME=MEMT:0..1;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO MEMT NAME=MEMT:0..1;


682 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426d
MEMT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
None.
Example of Command Execution:
Getsubo MEMT:NAME=MEMT:0;
GETTEST MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT GETTEST MEMT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
GETTEST MEMT NAME=MEMT:0..1;


A30808-X3247-M230-6-7619

683
CML:BSC MEMT
Id:0900d805800d426d
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest MEMT:NAME=MEMT:0;
LOCK MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT LOCK MEMT
GETTEST MEMT:NAME=MEMT:0;
name = TEST:<n>
mOts = MEMT:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK MEMT NAME=MEMT:0..1;


684 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426d
MEMT
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock MEMT:NAME=MEMT:0;
PERFTEST MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT PERFTEST MEMT
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state.
PERFTEST MEMT NAME=MEMT:0..1;


A30808-X3247-M230-6-7619

685
CML:BSC MEMT
Id:0900d805800d426d
Command Description:
This command is used to perform a test on the selected MEMT object; the test consists
of the following phases:
Accessibility Test (start phase),
DUAM Test - MPCC Side (WP1),
DUAM Test - TDPC Side (WP2),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST MEMT:NAME=MEMT:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases


686 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426d
MEMT
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest MEMT:NAME=MEMT:0;
STOPTEST MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT STOPTEST MEMT
Applicability:
Phase 2.
Visibility level: 2.
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
MOTS_NOT_LOCKED
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests are possible.
STOPTEST MEMT NAME=MEMT:0..1;


A30808-X3247-M230-6-7619

687
CML:BSC MEMT
Id:0900d805800d426d
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STOPTEST MEMT:NAME=MEMT:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = MEMT:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.


688 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d426d
MEMT
Application Guidelines:
None.
Example of Command Execution:
Stoptest MEMT:NAME=MEMT:0;
SWITCH MEMT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT SWITCH MEMT
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows the standby status exchange of the duplicated objects from "Pro-
viding Service" to "Hot Standby" and viceversa.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
The selected object must be equipped and in "enabled-providing service" state and its
duplicated copy must be in "enable-cold/hot standby" state.
Example of Command Execution:
Switch MEMT:NAME=MEMT:0;
UNLOCK MEMT
SWITCH MEMT NAME=MEMT:0..1;
ALREADY_IN_TARGET_STATE
OTHER_COPY_INVALID_STATE
UNSUCCESSFUL_COMMAND_REJECTED
UNLOCK MEMT NAME=MEMT:0..1;


A30808-X3247-M230-6-7619

689
CML:BSC MEMT
Id:0900d805800d426d
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MEMT UNLOCK MEMT
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the MEMT card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock MEMT:NAME=MEMT:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


690 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
MPCC
The MPCC is the administrative processor of the SBS system; it is based on a 16 MHz
80C386 SX microprocessor. It is a redundant unit in the active/standby mode.
GET MPCC STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GET MPCC STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
MPCC object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Standby Status (STNDBY)
Unknown Status (UNK).
This command allows to display the administrative, operational, usage state and all the
status attributes of a specified object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get MPCC STAT:NAME=MPCC:0;
GET MPCC STAT NAME=MPCC:0..1;


A30808-X3247-M230-6-7619

691
CML:BSC MPCC
Id:0900d805800d4272
GETINFO MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETINFO MPCC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The "RSU running" object and the "RSU version".
2. For each MPCC card:
the firmware version
the states and statuses: AST, OST, STNDBYST, PRS.
the MAC0 and MAC1 fields
3. The board version: old or new.
4. The active processor operational data (Peak Detection, Mobile Average and
Variance for several type of processor data).
5. The operational data of the active processor: real time, current OS time, OS time of
last Task init, type and OS time of the last exception, number of task init from last
full, number of full init from last bring-up, the exception number from last task, full
and bring-up init.
6. For all dynamic memory pool type: the used and total buffer numbers.
7. Total and largest block available.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO MPCC ACK:
BSC_CONTROLLER -> LMT_LOCAL
02:30:41 02/01/1992
*** INFORMATION ***
GETINFO REPORT:
NAME = MPCC:0
RSU RUNNING: RSUEXE 0-1
RSU VERSION: 02-06-01-01-00-00_00-01-10
GETINFO MPCC NAME=MPCC:0..1;


692 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
MPCC 0:
FIRMWARE VERSION: SFM1101
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
STANDBY STATUS: PROVIDING_SERVICE
PROCEDURAL STATUS: NONE
MAC0: 123:12:34:56:77:00
MAC1: 123:122:34:56:77:00
MPCC 1:
FIRMWARE VERSION: SFM1101
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
STANDBY STATUS: HOT_STANDBY
PROCEDURAL STATUS: NONE
MAC0: 123:12:34:56:77:00
MAC1: 123:122:34:56:77:00

PROCESSOR TYPE: NEW_BOARD_VERSION
ACTIVE PROCESSOR OPERATIONAL DATA:
REAL TIME LOAD: 31%
CURRENT OS TIME: 0049:05:54
OS TIME OF LAST TASK INIT: 0000:00:00
OS TIME OF LAST EXCEPTION: 0000:00:00
TYPE OF LAST EXCEPTION: 244
NUMBER OF TASK INIT SINCE LAST FULL INIT: 0001
NUMBER OF FULL INIT SINCE LAST BRING-UP: 0001
NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000
NUMBER OF EXCEPTION SINCE LAST FULL INIT: 0000
NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000
DYNAMIC MEMORY USAGE:
0: 0017/0050 1: 0057/0100 2: 0019/0064 3: 0012/0030 4: 0017/0031
5: 0000/0001 6: 0000/0001 7: 0001/0068 8: 0002/0200 9: 0000/0070
A: 0000/0014
TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/00022344


A30808-X3247-M230-6-7619

693
CML:BSC MPCC
Id:0900d805800d4272
END OF REPORT
- Operation Failed
GETINFO MPCC NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack MPCC:
name = MPCC:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
The attribute TYPE OF LAST EXCEPTION is reserved for the developer.
Example of Command Execution:
Getinfo MPCC:NAME=MPCC:0;
GETRELATIONSHIP MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETRELATIONSHIP
MPCC
Applicability:
Phase 2.
Visibility level: 1.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
MPCC
NAME=MPCC:0..1;


694 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.
For the MPCC object the MEL is the related FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship MPCC:NAME=MPCC:0;
GETSUBO MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETSUBO MPCC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO MPCC NAME=MPCC:0..1;


A30808-X3247-M230-6-7619

695
CML:BSC MPCC
Id:0900d805800d4272
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
None.
Example of Command Execution:
Getsubo MPCC:NAME=MPCC:0;
GETTEST MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC GETTEST MPCC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETTEST MPCC NAME=MPCC:0..1;
GETTEST MPCC:NAME=MPCC:0;
name = TEST:<n>
mOts = MPCC:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor


696 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest MPCC:NAME=MPCC:0;
LOCK MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC LOCK MPCC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK MPCC NAME=MPCC:0..1;


A30808-X3247-M230-6-7619

697
CML:BSC MPCC
Id:0900d805800d4272
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock MPCC:NAME=MPCC:0;
PERFTEST MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC PERFTEST MPCC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected MPCC object; the test consists
of the following phases:
Accessibilty Test (start phase),
ESSC2 & Alarm Test (WP1),
FW Card & Hot Link Test (WP2),
MPCC FW Update (WP3),
End Test (end phase).
Long Names:
NAME Addres of the managed object
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
CRITICAL_ALARM_REJECTED
The command has bee rejected due to high criticity of the
system state.
PERFTEST MPCC NAME=MPCC:0..1;


698 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
System Responses:
- Operation Completed
- Operation Failed
PERFTEST MPCC:NAME=MPCC:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase. phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)


A30808-X3247-M230-6-7619

699
CML:BSC MPCC
Id:0900d805800d4272
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
3. During the execution of the command PERFTEST on the board MPCC, the system
verify the presence of a firmware file stored in the BSC disk and related to the board,
if a file is present it performs the verification of the loaded Firmware version towords
the Firmware file, if the version differs then it automatically proceeds to the updating.
The Firmware file must be stored in a dedicated directory structure created using
Creatdir commands and stored using using dnlFile commands.
Example of Command Execution:
Perftest MPCC:NAME=MPCC:0;
STOPTEST MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC STOPTEST MPCC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
MOTS_NOT_LOCKED
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests possible.
STOPTEST MPCC NAME=MPCC:0..1;


700 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest MPCC:NAME=MPCC:0;
STOPTEST MPCC:NAME=MPCC:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = MPCC:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.


A30808-X3247-M230-6-7619

701
CML:BSC MPCC
Id:0900d805800d4272
SWITCH MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC SWITCH MPCC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows the standby status exchange of the duplicated objects from "Pro-
viding Service" to "Hot Standby" and viceversa.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The selected object must be equipped and in "enabled-providing service" state and
its duplicated copy must be in "enable-cold/hot standby" state.
2. The CMISE, FTAM and CBCL services are located on the MPCC processor; so, as
a consequence of an MPCC switch, all the established CMISE, FTAM and CBCL
connections are lost. At the end of the switch procedure, these services will be avail-
able again on the new running MPCC copy.
Example of Command Execution:
Switch MPCC:NAME=MPCC:0;
UNLOCK MPCC
SWITCH MPCC NAME=MPCC:0..1;
ALREADY_IN_TARGET_STATE
OTHER_COPY_INVALID_STATE
UNSUCCESSFUL_COMMAND_REJECTED
UNLOCK MPCC NAME=MPCC:0..1;


702 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4272
MPCC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE MPCC UNLOCK MPCC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the MPCC card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock MPCC:NAME=MPCC:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


A30808-X3247-M230-6-7619

703
CML:BSC NEYESUSW
Id:0900d805800d4275
NEYESUSW
The NEYESUSW instances identify BTSE or TRAUE software loads present on BSC
disk which can be loaded on BTSE/TRAUE network entities.
40 instances for this object are allowed.
All related commands consist of two fields but only one can be used (NAME or USER
LABEL SWLH).
GET NEYESUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GET
NEYESUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the different attributes of BTS and/or
TRAU software loads.
Long Names:
IDNEYESUSW Addres of the managed object
IDNEYESUSW identifierNEYESUSW
ULAB userLabel
VER version
NTWEL networkElement
RELRSU relatedRSU
System Responses:
- Operation Completed
GET NEYESUSW IDNEYESUSW= [,REQATTL= ULAB ,VER ,NTWEL ,REL-
RSU];
ULAB: userLabel
VER: version
NTWEL: networkElement
RELRSU: relatedRSU


704 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4275
NEYESUSW
GET NEYESUSW BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET NEYESUSW BASICS
None.
Example of Command Execution:
Get NEYESUSW:NAME=NEYESUSW:0,REQATTL=VER&NTWEL&RELRSU;
Get NEYESUSW:IDNEYESUSW="userLabel"-
BTSE,REQATTL=VER&NTWEL&RELRSU;
GET NEYESUSW BASICS
Get NEYESUSW BASICS:NAME=NEYESUSW:0;
Get NEYESUSW BASICS:IDNEYESUSW="userLabel"-BTSE;
GET NEYESUSW BASICS
ULAB: userLabel
VER: version
NTWEL: networkElement
RELRSU: relatedRSU
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another in progress.
OBJECT_NOT_FOUND
The referenced object does not exist.
ABORT_BY_SYSTEM_NCK
An internal system abort has occurred.
GET NEYESUSW
BASICS
;


A30808-X3247-M230-6-7619

705
CML:BSC NEYESUSW
Id:0900d805800d4275
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GET
NEYESUSW BASICS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the different attributes of BTS and/or
TRAU software loads.
Long Names:
IDNEYESUSW Addres of the managed object
ULAB userLabel
VER version
NTWEL networkElement
RELRSU relatedRSU
System Responses:
See GET NEYESUSW
Application Guidelines:
See GET NEYESUSW
Example of Command Execution:
See GET NEYESUSW
GET NEYESUSW STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GET
NEYESUSW STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
NEYESUSW object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
GET NEYESUSW STAT IDNEYESUSW=;


706 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4275
NEYESUSW
Control Status (CTS)
Unknown Status (UNK).
Long Names:
IDNEYESUSW Addres of the managed object
IDNEYESUSW identifierNEYESUSW
System Responses:
- Operation Completed
Refer to command description.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get NEYESUSW STAT:NAME=NEYESUSW:0;
Get NEYESUSW STAT:IDNEYESUSW="userLabel"-BTSE;
GETINFO NEYESUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW GETINFO
NEYESUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. For the related SW load header file:
Instance identifier,
Network element type,
User label associated,
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.
GETINFO NEYESUSW IDNEYESUSW=;


A30808-X3247-M230-6-7619

707
CML:BSC NEYESUSW
Id:0900d805800d4275
Version number,
Related files,
Operational state;
2. For each executable file present in the SW load header:
Instance identifier,
Processor type,
Version number,
Related files,
Operational state;
3. List of Network Elements for which the NEYESUSW instance is "backupESU".
( I ) If the LMT is connected in remote mode, it is not possible to execute this command.
Long Names:
IDNEYESUSW Addres of the managed object
IDNEYESUSW identifierNEYESUSW
System Responses:
- Operation Completed
GETINFO NEYESUSW ACK:
... ...
SBS RSUSWLH INSTANCE: RSUSWLH 11
NEY TYPE: BTSE
USERLABEL: 262LoadBTS1hs011424
VERSION: 01-01-14-00-24-00_02-04-25
RELATEDFILES: HS011424.SWL
SBSOPERATIONALSTATE: ENABLED

SBS RSUEXE INSTANCE: RSUEXE 0
SBSPROCTYPE: VAMBTSE
VERSION: 01-01-14-00-24-00_02-04-25
RELATEDFILES: VS011424.VAM
SBSOPERATIONALSTATE: ENABLED

SBS RSUEXE INSTANCE: RSUEXE 1
SBSPROCTYPE: TRXA
VERSION: 01-01-13-00-03-00_00-11-22
RELATEDFILES: BTSARCO1.SWI
SBSOPERATIONALSTATE: ENABLED



708 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4275
NEYESUSW
... ...
SBS RSUEXE INSTANCE: RSUEXE 10
SBSPROCTYPE: LI
VERSION: 01-04-13-00-05-00_01-09-27
RELATEDFILES: BTSLICO4.SWI
SBSOPERATIONALSTATE: ENABLED

LIST OF NE: NE_NUMBER_075 NE_NUMBER_152
END OF REPORT
- Operation Failed
NACK CAUSES:
Application Guidelines:
The attribute "relatedFiles" displays only the file name without the complete BSC disk
storage path.
Example of Command Execution:
Getinfo NEYESUSW:NAME=NEYESUSW:0;
Getinfo NEYESUSW:IDNEYESUSW="userLabel"-BTSE;
NEDOWNLOAD NEYESUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW NEDOWN-
LOAD NEYESUSW
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
NEDOWNLOAD
NEYESUSW
NTWEL=;


A30808-X3247-M230-6-7619

709
CML:BSC NEYESUSW
Id:0900d805800d4275
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs Network Element download from BSC disk to BTSM or TRAU
EPROMs.
The MODE parameter is valid for BTSM only.
Long Names:
IDNEYESUSW Addres of the managed object
NTWEL networkElement
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
RELATED_OBJECTS_DISABLED
The NEYESUSW is in DISABLED state.
CRC_FAILED
The CRC control on the files to be downloaded fails.
SW_LOAD_HEADER_NOT_FOUND_NCK
The SWLH file is not present.
INCONSISTENT_STATE_NCK
The NEs are in an inconsistent status.
INCONSISTENT_DISK_STATE_NCK
One or more disk files are not found.
PROCESSING_ERROR_NCK
A function call (for example allocation of memory) fails.
DOWNLOAD_ALREADY_IN_PROGRESS_NCK
A download of the same NE is already in progress.
INVALID_PARAMETER_NCK
The input parameter is not valid.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in pregress.
OBKECT_ NOT_FOUND
The object involved in thos command doesn't exist.
NO_TASK_AVAILABLE


710 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4275
NEYESUSW
Application Guidelines:
1. This command is performed if Operational State attribute of NEYESUSW is
ENABLED.
2. If the command is given with the parameter MODE set at FORCED, the download
is always performed; otherwise (option UNFORCED set) the download is performed
or not if a software load not running, on that Network Element, is absent or not.
Example of Command Execution:
Nedownload NEYESUSW:NTWEL=BTSE,NELIST=NE_NUMBER_000 |
NE_NUMBER_001,ULAB="useLabel",MODE=FORCED;
NEDOWNLOADABO NEYESUSW
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT NEYESUSW NEDOWN-
LOADABO NEYESUSW
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command performs Network Element abort download from BSC disk to BTSM or
TRAU EPROMs.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
The Network Element download timeout is expired.
No free servers to perform the command.
NO_ADMITTED_OPERATION
Waiting for SDSM server activation
ABORT_BY_SYSTEM_NCK
The command is rejected due to an internal subsystemn abort.
NEDOWNLOADABO
NEYESUSW
NAME=NEYESUSW:0..39;
INVALID_PARAMETER_NCK


A30808-X3247-M230-6-7619

711
CML:BSC NEYESUSW
Id:0900d805800d4275
Application Guidelines:
This command is performed if a Network Element download procedure is in progress.
Example of Command Execution:
Nedownloadabo NEYESUSW:NAME=NEYESUSW:0;
No NE download in progress to abort.
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NE download operation can not be aborted.
NO_TASKS_AVAILABLE
NE download timeout is expired.


712 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4278
NSVC
NSVC
The NSVC (Network Service Virtual Container) functional object represents the
end-to-end communication between BSS and SGSN. At each side of Gb interface there
is one to one correspondence between NSVC and NSVL, then the NSVL can be seen
as an attribute of NSVC.
CREATE NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC CREATE NSVC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the NSVC object class. It can be done only if FRL
is created. The status at creation will be "Locked - Disabled/Offline".
When the GbIC have been aligned with the remote peer the NSVC object will be put in
Enabled state.
Long Names:
NAME Addres of the managed object
NSVCI nsvcIdentifier
NSVLI nsvlIdentifier
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE NSVC NAME=NSVC:0..755 ,NSVCI= ,NSVLI=;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The FRL object instance must be already equipped.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
NSVC instances greater than 31 or more than 16 NSVCs for PCU
are allowed only if the network card is NTWSNAP or
NTWSNAP_STLP.


A30808-X3247-M230-6-7619

713
CML:BSC NSVC
Id:0900d805800d4278
Application Guidelines:
None.
Example of Command Execution:
Create NSVC:NAME=NSVC:10,NSVCI=3,NSVLI=20-50;
DELETE NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC DELETE NSVC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the NSVC object class. It can
be done only if the NSVC is in locked state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
INVALID_ATTRIBUTE_VALUE
Different NSVCs of the same PCU cannot have the same NSVCI or
the same NSVLI.
DELETE NSVC NAME=NSVC:0..755;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a NSVC, the relative object instance must be in
LOCKED state.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The last NSVC can be deleted only if there are no PTPPKFs
equipped.
If a PTPPKF exists under a CPCU, at least one NSVC must be
equipped under that CPCU.


714 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4278
NSVC
Application Guidelines:
None.
Example of Command Execution:
Delete NSVC:NAME=NSVC:10;
GET NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GET NSVC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the NSVC
object class.
Long Names:
NAME Addres of the managed object
NSVCI nsvcIdentifier
NSVLI nsvlIdentifier
System Responses:
- Operation Completed
GET NSVC BASICS
- Operation Failed
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The last NSVC of a CPCU can be deleted only if there are no
PTPPKFs equipped or a PCU over IP exists under that CPCU.
GET NSVC NAME=NSVC:0..755 [,REQATTL= NSVCI ,NSVLI];
NAME: name
NSVCI: Network Service Virtual Connection Identifier
NSVLI: Network Service Virtual Link Identifier
NAME: name
NSVCI: Network Service Virtual Connection Identifier
NSVLI: Network Service Virtual Link Identifier


A30808-X3247-M230-6-7619

715
CML:BSC NSVC
Id:0900d805800d4278
NACK CAUSES:
Application Guidelines:
None.
GET NSVC BASICS
None.
Example of Command Execution:
Get NSVC:NAME=NSVC:0,REQATTL=NSVCI&NSVLI;
GET NSVC BASICS
Get NSVC BASICS:NAME=NSVC:0;
GET NSVC BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GET NSVC BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the NSVC
object class.
Long Names:
NAME Addres of the managed object
NSVCI nsvcIdentifier
NSVLI nsvlIdentifier
System Responses:
See GET NSVC
Application Guidelines:
See GET NSVC
Example of Command Execution:
See GET NSVC
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET NSVC BASICS NAME=NSVC:0..755;


716 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4278
NSVC
GET NSVC STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GET NSVC STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
NSVC object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get NSVC STAT:NAME=NSVC:0;
GETINFO NSVC
GET NSVC STAT NAME=NSVC:0..755;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO NSVC NAME=NSVC:0..755;


A30808-X3247-M230-6-7619

717
CML:BSC NSVC
Id:0900d805800d4278
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GETINFO NSVC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the NSVC: AST, OST, AVS, CST, PRS.
2. The PCU number.
3. Six samples for each type of the following counters for the last 5 minutes:
syntactic counter
semantic counter
error event counter
non-error event counter
other error event counter
congestion counter.
4. The list of max 400 PTPPKFs connected. The list is always set to skip value: there-
fore, the corresponding entries in layout it must mot be shown.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO NSVC ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GETINFO REPORT:
NAME = NSVC:0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
PCU NBR: 2
SYNTACTIC LAST 5 MIN (6 SAMPLES): 2 9
SEMANTIC LAST 5 MIN (6 SAMPLES): 1
ERROR EVENT LAST 5 MIN (6 SAMPLES): 30 45


718 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4278
NSVC
NON ERROR EVENT LAST 5 MIN (6 SAMPLES): 2 5 10
OTHER ERROR EVENT LAST 5 MIN (6 SAMPLES): 10
CONGESTION LAST 5 MIN (6 SAMPLES): 1
END OF REPORT
- Operation Failed
GETINFO NSVC NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack NSVC:
name = NSVC:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo NSVC:NAME=NSVC:0;
GETRELATIONSHIP NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GETRELATIONSHIP NSVC
UNSUCCESSFUL_OBJECT_NOT_EQUIPPED
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
NSVC
NAME=NSVC:0..755;


A30808-X3247-M230-6-7619

719
CML:BSC NSVC
Id:0900d805800d4278
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the NSVC object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW, PPXU and if the FRL object is connected via A interfce
BSMS and TPWR objects.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship NSVC:NAME=NSVC:0;
GETSUBO NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC GETSUBO NSVC
Applicability:
Phase 2.
Visibility level: 0.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO NSVC NAME=NSVC:0..755;


720 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4278
NSVC
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo NSVC:NAME=NSVC:0;
LOCK NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC LOCK NSVC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". Locking the
last NSVC means services interruptions for all PTPPKF attached to the PCU. The
command can cuase services interruption.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK NSVC NAME=NSVC:0..755;


A30808-X3247-M230-6-7619

721
CML:BSC NSVC
Id:0900d805800d4278
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
3. If the NSVC to be locked is the last available NSVC within the PCU the command is
rejected.
Example of Command Execution:
Lock NSVC:NAME=NSVC:0;
UNLOCK NSVC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NSVC UNLOCK NSVC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command removes the operator block and the unit remains in the operational state
as it is at the moment of the command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_INVALID_STATUS
UNSUCCESSFUL_INVALID_STATUS
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNLOCK NSVC NAME=NSVC:0..755;


722 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4278
NSVC
Application Guidelines:
None.
Example of Command Execution:
Unlock NSVC:NAME=NSVC:0;


A30808-X3247-M230-6-7619

723
CML:BSC NSVCIP
Id:0900d805800d427b
NSVCIP
The NSVCIP object is automatically created by system in accordance to the selected
type of configuration and to the configured IP endpoints.
In case of static configuration it is necessary to create a RNSVLIP for each remote
endpoint to configure, specifying each single meshed connection with local endpoint to
allow (by selecting all the connectionsit is possible to realize the fully meshed connection
even in static configuration). The system will automatically create an NSVCIP object for
each connection specified in the attribute list for the remote endpoint.
In case of the dynamic configuration the operator has to specify the "startup" SGSN
endpoint to be used for configuration procedure. The system will create the NSVCIPs
according to the result of this procedure, as soon as it is completed.
For each PCU it is possible to generate up to 256 NSVCIP objects.
GET NSVCIP STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVCIP GET NSVCIP STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
NSVCIP object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
GET NSVCIP STAT NAME=PCU:0..11/NSVCIP:0..255;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


724 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d427b
NSVCIP
Application Guidelines:
None.
Example of Command Execution:
Get NSVCIP STAT:NAME=PCU:0/NSVCIP:3;
GETRELATIONSHIP NSVCIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVCIP GETRELATION-
SHIP NSVCIP
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the NSVCIP object the related HMOs are the following: EPWR, PWRD, MPCC,
TDPC, MEMT, PPXU and ES.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
The object instance must be already equipped.
GETRELATIONSHIP
NSVCIP
NAME=PCU:0..11/NSVCIP:0..255;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

725
CML:BSC NSVCIP
Id:0900d805800d427b
Example of Command Execution:
Getrelationship NSVLIP:NAME=PCU:0/NSVCIP:3;
GETSUBO NSVCIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVCIP GETSUBO NSVCIP
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo NSVLIP:NAME=PCU:0/NSVCIP:3;
GETSUBO NSVCIP NAME=PCU:0..11/NSVCIP:0..255;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


726 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d427e
NSVLIP
NSVLIP
The NSVLIP object is the container for the local endpoints associated data. For each
local IP endpoint of a PCU an NSVLIP object has to be created.
CREATE NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP CREATE NSVLIP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the NSVLIP object class.
Long Names:
NAME Addres of the managed object
LOCIPEP localIPEndpoint
WEID weightData
WEIS weigthSignalling
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE NSVLIP NAME=PCU:0..11/NSVLIP:0..15 ,LOCIPEP= [,WEID=]
[,WEIS=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The relavant PCU object instances must be already equipped.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
For each address port of a PCU up to 8 UPD ports can be config-
ured: NSVLIP instance from 0 to 7 must refer to PCU port0, while
NSVLIP instance from 8 to 15 must refer to PCU port1.
For each address port of PCU, more NSVLIP's instances cannot
have the same Udp port.
UNSUCCESSFUL_INVALID_COMMAND


A30808-X3247-M230-6-7619

727
CML:BSC NSVLIP
Id:0900d805800d427e
Application Guidelines:
None.
Example of Command Execution:
Create NSVLIP:NAME=PCU:0/NSVLIP:2:LOCIPEP=0-1024, WEID=10, WEIS=10;
DELETE NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP DELETE NSVLIP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the NSVLIP object class. The
object to be deleted shall be previously locked.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
No NSVLIP can be created if the superordinate PCU has the
GBSNS set to a value different from IPV4.
UNSUCCESSFUL_WRONG_PORT_NUMBER
The IP address points to a PCU port with a NULL address.
DELETE NSVLIP NAME=PCU:0..11/NSVLIP:0..15;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_LINK_CONNECTED
All the RNSVLIP object instances must not have the NSCONx
relative to NSVLIP into NSCONN attribute.


728 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d427e
NSVLIP
Example of Command Execution:
Delete NSVLIP:NAME=PCU:0/NSVLIP:2;
GET NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP GET NSVLIP
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the NSVLIP
object class.
Long Names:
NAME Addres of the managed object
LOCIPEP localIPEndpoint
WEID weightData
WEIS weigthSignalling
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get NSVLIP:NAME=PCU:0/NSVLIP:2,REQATTL=LOCIPEP&WEID&WEIS;
GET NSVLIP NAME=PCU:0..11/NSVLIP:0..15 [,REQATTL= LOCIPEP
,WEID ,WEIS];
LOCIPE
P:
localIPEndpoint
WEID: weigthData
WEIS: weigthSignalling
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

729
CML:BSC NSVLIP
Id:0900d805800d427e
GET NSVLIP BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP GET NSVLIP
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the NSVLIP
object class.
Long Names:
NAME Addres of the managed object
LOCIPEP localIPEndpoint
WEID weightData
WEIS weigthSignalling
System Responses:
See GET NSVLIP
Application Guidelines:
See GET NSVLIP
Example of Command Execution:
See GET NSVLIP
GET NSVLIP STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP GET NSVLIP STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
NSVLIP object:
GET NSVLIP BASICS NAME=PCU:0..11/NSVLIP:0..15;
GET NSVLIP STAT NAME=PCU:0..11/NSVLIP:0..15;


730 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d427e
NSVLIP
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get NSVLIP STAT:NAME=PCU:0/NSVLIP:2;
GETRELATIONSHIP NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP GETRELATIONSHIP
NSVLIP
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the NSVLIP object the related HMOs are the following: EPWR, PWRD, MPCC,
TDPC, MEMT, PPXU and ES.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETRELATIONSHIP
NSVLIP
NAME=PCU:0..11/NSVLIP:0..15;


A30808-X3247-M230-6-7619

731
CML:BSC NSVLIP
Id:0900d805800d427e
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
Example of Command Execution:
Getrelationship NSVLIP:NAME=PCU:0/NSVLIP:2;
GETSUBO NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP GETSUBO NSVLIP
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO NSVLIP NAME=PCU:0..11/NSVLIP:0..15;


732 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d427e
NSVLIP
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo NSVLIP:NAME=PCU:0/NSVLIP:2;
LOCK NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP LOCK NSVLIP
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
The command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK NSVLIP NAME=PCU:0..11/NSVLIP:0..15;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state.


A30808-X3247-M230-6-7619

733
CML:BSC NSVLIP
Id:0900d805800d427e
Application Guidelines:
The administrative state Locked will survive at the Full Init (and consequently to the load
database).
Example of Command Execution:
Lock NSVLIP:NAME=NAME=PCU:0/NSVLIP:2;
SET NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP SET NSVLIP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the NSVLIP parameters.
Long Names:
NAME Addres of the managed object
LOCIPEP localIPEndpoint
WEID weightData
WEIS weigthSignalling
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
SET NSVLIP NAME=PCU:0..11/NSVLIP:0..15 [,LOCIPEP=] [,WEID=]
[,WEIS=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_STATUS
In order to set the LOCIPEP attribute the object must be in locked
state.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
For each address port of a PCU up to 8 UPD ports can be config-
ured: NSVLIP instance from 0 to 7 must refer to PCU port0, while
NSVLIP instance from 8 to 15 must refer to PCU port1.


734 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d427e
NSVLIP
Application Guidelines:
None.
Example of Command Execution:
Set NSVLIP:NAME=PCU:0/NSVLIP:2:LOCIPEP=0-1024, WEID=10, WEIS=10;
UNLOCK NSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU NSVLIP UNLOCK NSVLIP
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked"
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
For each address port of PCU, more NSVLIP's instances cannot
have the same Udp port.
UNSUCCESSFUL_WRONG_PORT_NUMBER
The IP address points to a PCU port with a NULL address.
UNLOCK NSVLIP NAME=PCU:0..11/NSVLIP:0..15;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


A30808-X3247-M230-6-7619

735
CML:BSC NSVLIP
Id:0900d805800d427e
Example of Command Execution:
Unlock NSVLIP:NAME=PCU:0/NSVLIP:2;


736 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
NTW
The NTW object represents the switching network of the BSC; it is a redundant unit in
the active/standby mode and it is controlled by the MPCC.
FORCSYNC NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW FORCSYNC NTW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to force the free-running state of the active PLLH, based on the
tune word stored into the internal semi-permanent memory (EEPROM) of the card or
based on the DAC (Digit to Analog Converter) output word.
Long Names:
NAME Addres of the managed object
WRTYP wordType
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Forcsync NTW:NAME=NTW:0,WRTYP=Tune;
FORCSYNC NTW NAME=NTW:0..1 ,WRTYP=;
UNSUCCESSFUL_NTW_OUTAGE
Both copies of network are out of service.
UNSUCCESSFUL_WRONG_COPY
The command has been sent to standby copy instead of the active
one.
UNSUCCESSFUL_HW_FAILURE
Hardware problems during the execution of command.


A30808-X3247-M230-6-7619

737
CML:BSC NTW
Id:0900d805800d4882
GET NTW STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GET NTW STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
NTW object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get NTW STAT:NAME=NTW:0;
GETRELATIONSHIP NTW
GET NTW STAT NAME=NTW:0..1;
GETRELATIONSHIP
NTW
NAME=NTW:0..1;


738 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GETRELATIONSHIP
NTW
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.

For the NTW object the MEL is the related FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship NTW:NAME=NTW:0;
GETSUBO NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GETSUBO NTW
Applicability:
Phase 2.
Visibility level: 0.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO NTW NAME=NTW:0..1;


A30808-X3247-M230-6-7619

739
CML:BSC NTW
Id:0900d805800d4882
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
None.
Example of Command Execution:
Getsubo NTW:NAME=NTW:0;
GETSYNC NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GETSYNC NTW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the currently used synchronization source, the current
value of the DAC (Digit to Analog Converter) output word into memory and the tune word
into the semi-permanent location. This can give the way to evaluate the quality of the
tune word with respect to the currently frequency generated by the system.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETSYNC NTW NAME=NTW:0..1;
Successful
VERSION This attribute identifies the Hw and Fw version.


740 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Validity range:
version 20 ASCII characters string;
SYNCOPMO This attribute defines the Sync Operation Mode.
Validity range:
syncOpMode SYNC
ASYNC_ON_TUNE
ASYNC_ON_DAC
SLAVE
NAME1 Selected Source
SRCFREQ Source Frequency(#KHz)
Validity range:
sourceFrequency 0-4294967295
ELATIME The Elapsed Time is shown in days, hours, minutes and
seconds.
Validity range:
elapsedTime 0-4294967295
TUNEWR Tune Value.
Validity range:
tuneWord 0-65535
DACWR DAC value.
Validity range:
dacWord 0-65535
DELTA Delta
PHER PhaseError
UNSUCCESSFUL_NTW_OUTAGE
Both copies of network are out of service.
UNSUCCESSFUL_HW_FAILURE
Hardware problems during the execution of the command.
UNSUCCESSFUL_FAILED
The NTW copy which the command has been addressed
to is disabled.


A30808-X3247-M230-6-7619

741
CML:BSC NTW
Id:0900d805800d4882
Example of Command Execution:
Getsync NTW:NAME=NTW:0
GETTEST NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW GETTEST NTW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
GETTEST NTW NAME=NTW:0..1;
GETTEST NTW:NAME=NTW:0;
name = TEST:<n>
mOts = NTW:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.


742 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest NTW:NAME=NTW:0;
LOCK NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW LOCK NTW
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK NTW NAME=NTW:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.


A30808-X3247-M230-6-7619

743
CML:BSC NTW
Id:0900d805800d4882
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed, no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
3. It is emitted when the PLLH has become synchronized to an external source little
time ago, and the switch of the master PLLH (for LOCK or SWITCH command)
would leave the frequency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone PROVIDING SERVICE.
The same can happen if less than 5 minutes have passed since last switch of NTW.
4. The LOCK of both NTW objects leads to an interruption of the whole BSS call traffic.
The LOCK command for the second board is not refused and there is no system
warning generation.
Example of Command Execution:
Lock NTW:NAME=NTW:0;
PERFTEST NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW PERFTEST NTW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected NTW object; the test consists
of the following phases:
Accessibility Test (start phase),
UBEX Force Alarm Test (WP1),
PLLH Force Alarm Test (WP2),
PLLH FW Self Test (WP3),
SN Force Alarm Test (WP4),
SN16 Speech RAM Adderess Parity Test (WP5),
SN16 Speech RAM Data Parity Test (WP6),
SN16 Control RAM Adderess Parity Test (WP7),
End Test (end phase).
Long Names:
NAME Addres of the managed object
PERFTEST NTW NAME=NTW:0..1;


744 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
System Responses:
- Operation Completed
- Operation Failed
PERFTEST NTW:NAME=NTW:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed)..
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase. phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)


A30808-X3247-M230-6-7619

745
CML:BSC NTW
Id:0900d805800d4882
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest NTW:NAME=NTW:0;
STOPTEST NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW STOPTEST NTW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
MOTS_NOT_LOCKED
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cutions of tests are possible.
STOPTEST NTW NAME=NTW:0..1;
STOPTEST NTW:NAME=NTW:0;


746 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest NTW:NAME=NTW:0;
SWITCH NTW
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = NTW:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
SWITCH NTW NAME=NTW:0..1;


A30808-X3247-M230-6-7619

747
CML:BSC NTW
Id:0900d805800d4882
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW SWITCH NTW
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows the standby status exchange of the duplicated objects from "Pro-
viding Service" to "Hot Standby" and viceversa.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The selected object must be in "enabled-providing service" state and its duplicated
copy must be in "enable-cold/hot standby" state, otherwise the response message
will be ALREADY_IN_TARGET_STATE.
2. The network switch command cannot be performed within 5 minutes from the
previous one if a SYNC or SYNE object is configured due to hardware constraints.
Example of Command Execution:
Switch NTW:NAME=NTW:0;
UNLOCK NTW
ALREADY_IN_TARGET_STATE
OTHER_COPY_INVALID_STATE
UNSUCCESSFUL_COMMAND_REJECTED
STANDBY_PLLH_DAC_WORD_EVOLVING
It is emitted when the PLLH has become synchronized to an
external source little time ago, and the switch of the master
PLLH (for LOCK or SWITCH command) would leave the fre-
quency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone
PROVIDING SERVICE. The same can happen if less than 5
minutes have passed since last switch of NTW.
UNLOCK NTW NAME=NTW:0..1;


748 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW UNLOCK NTW
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the NTW card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock NTW:NAME=NTW:0;
UPDATETUNE NTW
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE NTW UPDATETUNE NTW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to calibrate the PLLH. Calibrating PLLH means to copy the actual
DAC word into a permanent memory, when the card is synchronized, in order to
memorize permanently the frequency of the synchronizing signal (the DAC value is the
numerical value corresponding to the frequency of the oscillator when it will work in
holdover mode. When synchronized, the DAC value represents the mean frequency of
the synchronizing signal).
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UPDATETUNE NTW NAME=NTW:0..1;


A30808-X3247-M230-6-7619

749
CML:BSC NTW
Id:0900d805800d4882
Calibration is not essential into a synchronized network but it is recommended to
execute it regularly, especially in case of a poor synchronized network, i.e. when there
is some probability to work in ASYNCHRONOUS mode.
Even in case of a synchronous network, the well calibrated PLLH will behave better in
the transitory phase from ASYNCHRONOUS to SYNCHRONIZED operating mode
reducing the amplitude of the transitory phase error.
It is also important to have a PLLH not completely un-calibrated because the UPDATE-
TUNE NTW is used by PLLH FW in the initial phase measurement of the external
signals (on which synchronize) and for auto-tests.
For further information see the PLLH Calibration procedure in the OMN:BSC manual.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The command must never be given on a PLLH powered for less than half an hour,
in order to avoid to un-calibrate the PLLH card.
2. In order to enter the command the following requirements must be fulfilled:
the PLLH card to be calibrated has to be powered without interruptions for at
least one day, better a week or more;
the mean frequency accuracy of the synchronizing signal must be better than
1E-9. If the accuracy of the frequency of the PCM line used to synchronize is
unknown, the best thing to do is to synchronize BSC externally using the SYNE
inputs connected to a local atomic generator (rubidium or cesium standard) and
then calibrate the PLLH;
the PLLH card must be synchronized since at least 5 minutes ("elapsed time")
for PLLH-V1 and jitter/wander free synchronization signal (this condition can be
UNSUCCESSFUL_NTW_OUTAGE
Both copies of network are out of service.
UNSUCCESSFUL_WRONG_COPY
The command has been sent to standby copy instead
of the active one.
UNSUCCESSFUL_HW_FAILURE
Hardware problems during the execution of the
command.
PLL_LOCK_IN PROGRESS


750 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4882
NTW
verified if the "phase error" parameter on LMT report is 0), since at least 5/7
hours for ITU-T G823 jitter/wander affected signal for PLLH-V2.
Example of Command Execution:
Updatetune NTW:NAME=NTW:0;


A30808-X3247-M230-6-7619

751
CML:BSC NUC
Id:0900d805800d428a
NUC
The NUC is a logical object that allows the semi-permanent connection between a
channel of Asub interface with a channel of Abis or A interface.
CREATE NUC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NUC CREATE NUC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the specific parameters for NUC object.
Long Names:
NAME Addres of the managed object
FRTERM fromTermination
TOTERM toTermination
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE NUC NAME=NUC:0..29 ,FRTERM= ,TOTERM=;
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
RELATED_PCMA_NOT_EQUIPPED
The PCMA, which the timeslot instance belongs to, must be already
equipped.
RELATED_PCMB_NOT_EQUIPPED
The PCMB, which the timeslot instance belongs to, must be already
equipped .
RELATED_PCMS_NOT_EQUIPPED
The PCMS, which the timeslot instance belongs to, must be already
equipped.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED


752 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428a
NUC
Application Guidelines:
If the NUC connects a PCMB timeslot with a PCMA timeslot, the timeslot of the PCMS
with the same number of the selected PCMA timeslot must not carry a X25A/SS7/NUC
link.
The timeslot of the PCMB or the PCMS must be not configured as
LPDLS or LPDLM or LPDLR.
The timeslot of the PCMB must be available (not already configured
as SUBTSLB object or Layer1ControlTS).
UNSUCCESSFUL_INVALID_CONNECTION
The From Termination and the ToTermination of a NUC object
cannot be on the same type of PCM.
At the creation of a NUC between a PCMS and a PCMA, both the
PCM lines must belong to the same TRAU.
UNSUCCESSFUL_INVALID_FROM_TERM
The From Termination of a NUC object can not be a PCMA line.
UNSUCCESSFUL_INVALID_TO_TERM
The To Termination of a NUC object cannot be a PCMB line.
UNSUCCESSFUL_INVALID_TIME_SLOT
If the NUC crosses the TRAU Network element, the timeslots of the
PCMS and of the PCMA must have the same number. This is due to
hardware constraining on TRAU.
The timeslot value is not compatible with the PCM line type
(PCMTYPE attribute of BSC object).
UNSUCCESSFUL_INVALID_STATUS
Before creating a NUC the relative TRAU object instance, if any,
must be in LOCKED state.
UNSUCCESSFUL_X25A_LINK
The timeslot of the PCMA/PCMS must not carry a X25A link.
Make reference to the Application Guideline.
UNSUCCESSFUL_SS7L_LINK
The timeslot of the PCMA/PCMS must not carry a SS7 link.
Make reference to the Application Guideline.
UNSUCCESSFUL_NUC_LINK
The timeslot of the PCMA/PCMB/PCMS must not carry a NUC link.
Make reference to the Application Guideline.
UNSUCCESSFUL_WRONG_ME_ID
The first field of the From Termination/To Termination attribute is
incorrect. For more details about its configuration rules see the
attribute description (Chapter 4 of this Manual).


A30808-X3247-M230-6-7619

753
CML:BSC NUC
Id:0900d805800d428a
Example of Command Execution:
Create NUC:NAME=NUC:3,FRTERM=PCMB:2-1,TOTERM=PCMS:3-20;
DELETE NUC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NUC DELETE NUC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a NUC object instance.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete NUC:NAME=NUC:4;
GET NUC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NUC GET NUC
DELETE NUC NAME=NUC:0..29;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a NUC, the relative TRAU object instance, if
any, must be in LOCKED state.
GET NUC NAME=NUC:0..29 [,REQATTL= FRTERM ,TOTERM];


754 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428a
NUC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of a NUC object instance.
Long Names:
NAME Addres of the managed object
FRTERM fromTermination
TOTERM toTermination
System Responses:
- Operation Completed
GET NUC BASICS
- Operation Failed
Application Guidelines:
None.
GET NUC BASICS
None.
Example of Command Execution:
Get NUC:NAME=NUC:0,REQATTL=FRTERM&TOTERM;
GET NUC BASICS
Get NUC BASICS:NAME=NUC:0;
GET NUC BASICS
FRTERM: fromTermination
TOTERM: toTermination
FRTERM: fromTermination
TOTERM: toTermination
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET NUC BASICS NAME=NUC:0..29;


A30808-X3247-M230-6-7619

755
CML:BSC NUC
Id:0900d805800d428a
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NUC GET NUC BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of a NUC object instance.
Long Names:
NAME Addres of the managed object
FRTERM fromTermination
TOTERM toTermination
System Responses:
See GET NUC
Application Guidelines:
See GET NUC
Example of Command Execution:
See GET NUC
GET NUC STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NUC GET NUC STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
NUC object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
GET NUC STAT NAME=NUC:0..29;


756 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428a
NUC
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get NUC STAT:NAME=NUC:5;
GETRELATIONSHIP NUC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL NUC GETRELATIONSHIP NUC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the NUC object the related HMOs are the following: LICD/LICDS, EPWR, BSMS,
TPWR, PWRD, MPCC, TDPC, MEMT, NTW and PPXL.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETRELATIONSHIP
NUC
NAME=NUC:0..29;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

757
CML:BSC NUC
Id:0900d805800d428a
Application Guidelines:
None.
Example of Command Execution:
Getrelationship NUC:NAME=NUC:0;
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


758 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428d
OMAL
OMAL
The OMAL object is the link connecting the BSC, through the IXLT, to the RC or LMT
with X.25 protocol.
CREATE OMAL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL CREATE OMAL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds the OMAL object that represents the logical link for the communi-
cation with the RC.
Long Names:
NAME Addres of the managed object
LINKTYPE linkType
X121ADDR x121Addr
OMCCPT omcCapabilityTimer
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE OMAL NAME=OMAL:0..1 [,LINKTYPE=] [,X121ADDR=] [,OMC-
CPT=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Different copies of OMAL must have different X121ADDR.
The X121ADDR attribute must be set to a value different from NULL
if LINKTYPE attribute is set to X25A/X25D.
The X121ADDR attribute cannot be set to a value different from
NULL if LINKTYPE attribute is set to IPLI.
The OMCCPT attribute cannot be set to NULL if LINKTYPE attribute
is set to X25A/X25D.


A30808-X3247-M230-6-7619

759
CML:BSC OMAL
Id:0900d805800d428d
Application Guidelines:
The X121ADDR must be a numeric string.
Example of Command Execution:
Create OMAL:NAME=OMAL:0,LINKTYPE=X25D,
X121ADDR="123451234512345123451234512345123",OMCCPT=<DEFAULT>;
DELETE OMAL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL DELETE OMAL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the OMAL object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
The OMCCPT attribute cannot be set to a value different from NULL
if LINKTYPE attribute is set to IPLI.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The X25A/X25D object instance must be already equipped.
The IPLI object must be already equipped if the operator sets
LINKTYPE attribute to the value IPLI.
UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED
The creation of copy #1 is subordinated to the presence of copy #0.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Only one OMAL instance (OMAL:0) can be equipped if the
LINKTYPE attribute is set to IPLI.
DELETE OMAL NAME=OMAL:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


760 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428d
OMAL
Application Guidelines:
None.
Example of Command Execution:
DELETE OMAL:NAME=OMAL:0;
GET OMAL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the OMAL object.
Long Names:
NAME Addres of the managed object
LINKTYPE linkType
X121ADDR x121Addr
OMCCPT omcCapabilityTimer
System Responses:
- Operation Completed
GET OMAL BASICS
UNSUCCESSFUL_COPY_ONE_EQUIPPED
The deletion of the instance #0 is possible only if the
copy #1 is not present.
GET OMAL NAME=OMAL:0..1 [,REQATTL= LINKTYPE ,X121ADDR
,OMCCPT];
NAME: name
LINKTYPE: linkType
X121ADDR: x121Addr
OMCCPT: omcCapabilityTimer
NAME: name
X121ADDR: x121Addr


A30808-X3247-M230-6-7619

761
CML:BSC OMAL
Id:0900d805800d428d
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET OMAL BASICS
None.
GET OMAL X25INFO
None
Example of Command Execution:
Get OMAL:NAME=OMAL:0,REQATTL=LINKTYPE&X121ADDR&OMCCPT;
GET OMAL BASICS
Get OMAL BASICS:NAME=OMAL:0;
GET OMAL X25INFO
Get OMAL X25INFO:NAME=OMAL:0;
GET OMAL BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the OMAL object.
Long Names:
NAME Addres of the managed object
LINKTYPE linkType
OMCCPT: omcCapabilityTimer
NOT_EQUIPPED
The object instance must be already equipped.
GET OMAL BASICS NAME=OMAL:0..1;


762 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428d
OMAL
System Responses:
See GET OMAL
Application Guidelines:
See GET OMAL
Example of Command Execution:
See GET OMAL
GET OMAL X25INFO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL X25INFO
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the OMAL object.
Long Names:
NAME Addres of the managed object
X121ADDR x121Addr
OMCCPT omcCapabilityTimer
System Responses:
See GET OMAL
Application Guidelines:
See GET OMAL
Example of Command Execution:
See GET OMAL
GET OMAL STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GET OMAL STAT
Applicability:
Phase 2.
GET OMAL X25INFO NAME=OMAL:0..1;
GET OMAL STAT NAME=OMAL:0..1;


A30808-X3247-M230-6-7619

763
CML:BSC OMAL
Id:0900d805800d428d
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
OMAL object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
Application Guidelines:
1. The object selected must be created.
2. Only sets with raised bits are shown.
3. Explanation of the meaning of OMAL ,IXLT, CBCL, X25A and X25D status:
The handling of the status attributes may be summarized as follows:
The operational state handling may be summarized as follows:
Value OMAL
standby PROVIDINGSERVICE not used
HOTSTANDBY not used
COLDSTANDBY not used
NULL_STATUS not used
availability FAILED CBCL DISABLED layer 7 is down
DEGRADED not used
OFF_DUTY not used
DEPENDENCY X25A/X25D is DISABLED or
LOCKED
procedural INITIALIZING not used
OMAL


764 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428d
OMAL
Example of Command Execution:
Get OMAL STAT:NAME=OMAL:0;
GETRELATIONSHIP OMAL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GETRELATIONSHIP OMAL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the OMAL object the related HMOs are the following: IXLT, PWRD, MPCC, EPWR
and either X25D (for direct OMC/BSC connection) or X25A, LICD/LICDS, TDPC,
MEMT, NTW, BSMS and TPWR (for OMC/BSC connection via A interface).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
ENABLED layer 7 up
DISABLED layer 7 down
GETRELATIONSHIP
OMAL
NAME=OMAL:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

765
CML:BSC OMAL
Id:0900d805800d428d
Example of Command Execution:
Getrelationship OMAL:NAME=OMAL:0;
GETSUBO OMAL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL GETSUBO OMAL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo OMAL:NAME=OMAL:0;
SET OMAL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OMAL SET OMAL
GETSUBO OMAL NAME=OMAL:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET OMAL NAME=OMAL:0..1 [,X121ADDR=] [,OMCCPT=];


766 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d428d
OMAL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command set the parameters for the OMAL object.
Long Names:
NAME Addres of the managed object
X121ADDR x121Addr
OMCCPT omcCapabilityTimer
System Responses:
- Operation Completed
Successful
- Operation Failed
Application Guidelines:
The X121ADDR must be a numeric string.
Example of Command Execution:
Set OMAL:NAME=OMAL:0,X121ADDR="956712345123451234512345123451234",
OMCCPT=<DEFAULT>;
NACK CAUSES::
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order
to perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Different copies of OMAL must have different X121ADDR.
The X121ADDR attribute cannot be set to NULL if LINKTYPE
attribute is set to X25A/X25D.
The X121ADDR attribute cannot be set to a value different from
NULL if LINKTYPE attribute is set to IPLI.
The OMCCPT attribute cannot be set to NULL if LINKTYPE
attribute is set to X25A/X25D.
The OMCCPT attribute cannot be set to a value different from
NULL if LINKTYPE attribute is set to IPLI.


A30808-X3247-M230-6-7619

767
CML:BSC OPC
Id:0900d805800d4457
OPC
The OPC object is the originating point in the BSC for common channel signalling n. 7.
CREATE OPC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC CREATE OPC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the values of the parameters that are used in the Common
Channel Signalling System (SS7).
Long Names:
NAME Addres of the managed object
SS7MTPTYP ss7MtpType
OPC originatingPointCode
MSCSPC mscSignallingPointCode
NTWIND networkIndicator
BSSAPSSN bssapSsn
MSCPERTFLAG mscPeriocTestFlag
M2T1 mtl2Timer1
M2T2 mtl2Timer2
M2T3 mtl2Timer3
M2T4N mtl2Timer4N
M2T4E mtl2Timer4E
M2T5 mtl2Timer5
M2T6 mtl2Timer6
M2T7 mtl2Timer7
CREATE OPC NAME=OPC:0..0 [,SS7MTPTYP=] ,OPC= ,MSCSPC=
[,NTWIND=] [,BSSAPSSN=] [,MSCPERTFLAG=] [,M2T1=]
[,M2T2=] [,M2T3=] [,M2T4N=] [,M2T4E=] [,M2T5=] [,M2T6=]
[,M2T7=] [,FLOWCTH=] [,CONGTH=] [,SANTIME=]
[,ERRCORMTD=] [,N1=] [,N2=] [,M3T1=] [,M3T2=] [,M3T3=]
[,M3T4=] [,M3T5=] [,M3T12=] [,M3T13=] [,M3T14=]
[,M3T17=] [,M3T19=] [,M3T22OR20=] [,M3T23OR21=]
[,M3T1TM=] [,M3T2TM=] [,TCONN=] [,TIAS=] [,TIAR=]
[,TREL=] [,TGUARD=] [,TSBS=] [,TWCUSER=] [,TINT=]
[,SMLCSPC=] [,APLESSNBSC=] [,APLESSNSMLC=]
[,SMLCPERTFLAG=] [,M3T10=];


768 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
FLOWCTH flowcThreshold
CONGTH congThreshold
SANTIME sanityTimer
ERRCORMTD ccss7ErrorCorrectionMethod
N1 n1
N2 n2
M3T1 mtl3Timer1
M3T2 mtl3Timer2
M3T3 mtl3Timer3
M3T4 mtl3Timer4
M3T5 mtl3Timer5
M3T12 mtl3Timer12
M3T13 mtl3Timer13
M3T14 mtl3Timer14
M3T17 mtl3Timer17
M3T19 mtl3Timer19
M3T22OR20 mtl3Timer22or20
M3T23OR21 mtl3Timer23or21
M3T1TM mtl3Timert1tm
M3T2TM mtl3Timert2tm
TCONN tconn
TIAS tias
TIAR tiar
TREL trel
TGUARD tGuard
TSBS tsbs
TWCUSER twcUser
TINT tint
SMLCSPC sMLCSignallingPointCode
APLESSNBSC applPartSSNLCSEBSC
APLESSNSMLC applPartSSNLESMLC
SMLCPERTFLAG sMLCPeriocTestFlag
M3T10 mtl3Timer10
System Responses:
- Operation Completed
Successful
- Operation Failed


A30808-X3247-M230-6-7619

769
CML:BSC OPC
Id:0900d805800d4457
NACK CAUSES:
Application Guidelines:
1. OPC, MSCSPC and SMLCSPC attributes must differ from each other in at least one
field.
2. In CCITT case the subfield NetworkIdentifier of OPC, MSCSPC and SMLCSPC
attributes is not configurable, while in ANSI case it is mandatory.
3. If the attribute SS7MTPTYP is set at ANSI, the attributeNetworkCluster cannot
assume value 0 if 0<NIDEN<6.
4. Depending on the value of the attribute SS7MTPTYP the subfields of the attributes
OPC, MSCSPC and SMLCSPC have different ranges, as shown in the following
table:
5. If the attribute SS7MTPTYP is set at ANSI, the attribute NETWIND can assume only
the value NAT0.
6. Depending on the value of the attribute SS7MTPTYP of OPC object the timers
(except M2T5 timer) have different ranges, as shown in the following table:
The value assigned to M2T6 timer must be lower or equal to the M3T1TM one.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 1, n. 2, n. 3, n. 7, n. 9.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Make reference to Application Guidelines n. 4, n. 5, n. 6, n. 8, n. 15.
ANSI CCITT
Network Cluster Member 1-255 0-255
Network Cluster 0-255 0-63
Network Identifier 1-254 NO_CONFIG
Timer Name ANSI Range CCITT Range
M2T1 129-160 400-500
M2T2 50-300 50-1500
M2T3 50-140 10-15
M2T4N 15-30 75-95
M2T4E 4-7 4-5
M2T6 10-60 30-60
M2T7 5-20 5-20


770 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
7. The following tables show the possible values for CONGTHRE and FLOWCTH
parameters and the related percentage of transmit buffer used which cause the
request of load reduction measures or the subsequently discarding of messages.
8. Depending on the value of the attribute SS7MTPTYP of OPC object, the timers
M3T22OR20 an M3T22OR21 have different ranges, as shown in the following table:
9. The value assigned to M3T1TM timer must be greater or equal to the M2T6 one
(timer of OPC).
10. If a link interruption shorter than TGUARD timer value occurs, busy CIC's will not be
released; i.e. existing speech connections will be saved. After link re-alignment
(MTP) no reset message will be sent on the A-interface. If a link interruption longer
than TGUARD timer value occurs, the existing speech connections will be released
and after link re-alignment a reset message will be sent on theA-interface. To save
existing calls for a defined period of SS7 link short time failure, the timer values at
BSC and MSC side should be equal.
11. After a TDPC SWITCH the timer TIAS and TIAR at BSC side are reset to 0. Under
disadvantageous conditions, it may happen that no inactivity test message will be
sent towards MSC for more than 2 times of the TIAS interval. To prevent that the
MSC releases the SCCP connections, the TIAR timer from the MSC should be more
than 2 times of the TIAS timer from the BSC. Please note that, if several switchs are
performed in a short period of time, the above mentioned conditions are not suffi-
cient anymore.
12. The SCCP timer TGUARD has to be set with respect to the procedure of TDPC
switch. During this switch the SS7-links at the A-interface are initialized and there-
fore timer TGUARD has to be set bigger than 30 seconds. Recommended value is
CONGTHRE (congestion control
threshold)
FLOWCTH (flow control
threshold)
value abatment onset discard value abatment onset
0 = = = 0 = =
1 45 50 not used 1 50 60
2 45 50 55 2 50 65
3 30 35 40 3 50 70
4 35 40 45 4 40 50
5 40 45 50 5 40 55
6 45 50 55 6 40 60
7 45 55
8 45 60
9 45 65
Timer Name ANSI Range CCITT Range
M3T22OR20 18-24 36-72
M3T23OR31 18-24 36-72


A30808-X3247-M230-6-7619

771
CML:BSC OPC
Id:0900d805800d4457
50 seconds. In the case TGUARD expires the BSSMAP reset procedure will be per-
formed which leads to loss of all calls. Please don't forget to set the appropriate MSC
timer accordently.
13. The timer TGUARD must be set longer than ALARMT2 (LICD object) + TSBS.
Shorter values are useless and can cause a reset procedure at A interface also for
very short link interruption due to the time needed to complete the link realignment.
The TGUARD timer is used to supervise the Adjacent Signalling Point inacessibility.
It is started when the last SS7 goes down and it is stopped only when the first link is
completely aligned. The procedure to get to the complete alignment takes the fol-
lowing steps:
if the failure lasts longer than ALARMT2 (LICD object, default 1 sec.);
at the end of the failure the PCM is up at the expiration of the timer ALARMT1
(LICD object, default 20 sec.);
after M3T17 (default 1 sec.) plus M2T4E (default 500 ms.) the level 2 is in
service;
the SLTM - SLTA message are exchanged between the 2 network elements;
after that the SST - SSA messages are exchanged between BSC and MSC also
the SCCP is aligned.
The BSC sends the SST message when receives the SST from MSC or when the
TSBS timer expires. The alignment procedure is considered completed and the
timer TGUARD is stopped, only after receiving the SSA from the MSC.
14. As during TDPC switch SS7 links are initialized, it is recommandable to set
TGUARD at a value of 50 secs in order to allow proper behaviour during load con-
ditions too.
15. Depending on the value of the attribute SS7MTPTYP some timers of the OPC object
have different ranges, as shown in the following table:
Example of Command Execution:
Create OPC:NAME=OPC:0=,SS7MTPTYP=ANSI,OPC=3-5-10,
MSCSPC=2-4-8,NTWIND=NAT0,BSSAPSSN=30,MSCPERTFLAG=FALSE,
M2T1=400,M2T2=50,M2T3=10,M2T4N=75,M2T4E=4,M2T5=1,
M2T6=30,M2T7=5,FLOWCTH=0,CONGTH=0,SANITIME=0,
ERRCORMTD=BASIC_ERROR_CORRECTION,N1=110,N2=2000,TCONN=0,
TIAS=0,TIAR=0,TREL=0, TGUARD=0,TSBS=0,TWCUSER=0,TINT=0,SMLCSPC=1-
23-3,APLESSNBSC=<DEFAULT>,APLESSNSMLC=<DEFAULT>,
SMLCPERTFLAG=TRUE,M3T10=<DEFAULT>;
Parameter ANSI CCITT
TCONN 1-72 0-255
TIAS 60-120 0-255
TIAR 132-255 0-255
TREL 20-40 0-255


772 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
DELETE OPC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC DELETE OPC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an OPC previously created through the CREATE OPC
command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete OPC:NAME=OPC:0;
DELETE OPC NAME=OPC:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
All equipped SS7 data links must be deleted before submit-
ting the command: no SS7L can be equipped.


A30808-X3247-M230-6-7619

773
CML:BSC OPC
Id:0900d805800d4457
GET OPC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the timers for MTP Level 2 and Level 3
Protocol of the Common Channel Signalling System SS7.
Long Names:
NAME Addres of the managed object
SS7MTPTYP ss7MtpType
OPC originatingPointCode
MSCSPC mscSignallingPointCode
NTWIND networkIndicator
BSSAPSSN bssapSsn
MSCPERTFLAG mscPeriocTestFlag
T1UNIT t1Unit
M2T1 mtl2Timer1
T2UNIT t2Unit
M2T2 mtl2Timer2
T3UNIT t3Unit
M2T3 mtl2Timer3
T4NUNIT t4NUnit
GET OPC NAME=OPC:0..0 [,REQATTL= SS7MTPTYP ,OPC
,MSCSPC ,NTWIND ,BSSAPSSN ,MSCPERTFLAG
,T1UNIT ,M2T1 ,T2UNIT ,M2T2 ,T3UNIT ,M2T3 ,T4NUNIT
,M2T4N ,T4EUNIT ,M2T4E ,T5UNIT ,M2T5 ,T6UNIT ,M2T6
,T7UNIT ,M2T7 ,FLOWCTH ,CONGTH ,SANUNIT
,SANTIME ,ERRCORMTD ,N1 ,N2 ,T1UNIT1 ,M3T1
,T2UNIT1 ,M3T2 ,T3UNIT1 ,M3T3 ,T4UNIT ,M3T4
,T5UNIT1 ,M3T5 ,T12UNIT ,M3T12 ,T13UNIT ,M3T13
,T14UNIT ,M3T14 ,T17UNIT ,M3T17 ,T19UNIT ,M3T19
,T22OR20UNIT ,M3T22OR20 ,T23OR21UNIT
,M3T23OR21 ,T1TMUNIT ,M3T1TM ,T2TMUNIT ,M3T2TM
,TCONNUNIT ,TCONN ,TIASUNIT ,TIAS ,TIARUNIT ,TIAR
,TRELUNIT ,TREL ,TGUARDUNIT ,TGUARD ,TSBSUNIT
,TSBS ,TWCUNIT ,TWCUSER ,TINTUNIT ,TINT
,SMLCSPC ,APLESSNBSC ,APLESSNSMLC ,SMLCPERT-
FLAG ,T10UNIT ,M3T10];


774 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
M2T4N mtl2Timer4N
T4EUNIT t4EUnit
M2T4E mtl2Timer4E
T5UNIT t5Unit
M2T5 mtl2Timer5
T6UNIT t6Unit
M2T6 mtl2Timer6
T7UNIT t7Unit
M2T7 mtl2Timer7
FLOWCTH flowcThreshold
CONGTH congThreshold
SANUNIT sanityUnit
SANTIME sanityTimer
ERRCORMTD ccss7ErrorCorrectionMethod
N1 n1
N2 n2
T1UNIT1 t1Unit
M3T1 mtl3Timer1
T2UNIT1 t2Unit
M3T2 mtl3Timer2
T3UNIT1 t3Unit
M3T3 mtl3Timer3
T4UNIT t4Unit
M3T4 mtl3Timer4
T5UNIT1 t5Unit
M3T5 mtl3Timer5
T12UNIT t12Unit
M3T12 mtl3Timer12
T13UNIT t13Unit
M3T13 mtl3Timer13
T14UNIT t14Unit
M3T14 mtl3Timer14
T17UNIT t17Unit
M3T17 mtl3Timer17
T19UNIT t19Unit
M3T19 mtl3Timer19
T22OR20UNIT t22or20Unit
M3T22OR20 mtl3Timer22or20
T23OR21UNIT t23or21Unit


A30808-X3247-M230-6-7619

775
CML:BSC OPC
Id:0900d805800d4457
M3T23OR21 mtl3Timer23or21
T1TMUNIT t1tmUnit
M3T1TM mtl3Timert1tm
T2TMUNIT t2tmUnit
M3T2TM mtl3Timert2tm
TCONNUNIT tConnUnit
TCONN tconn
TIASUNIT tiasUnit
TIAS tias
TIARUNIT tiarUnit
TIAR tiar
TRELUNIT trelUnit
TREL trel
TGUARDUNIT tGuardUnit
TGUARD tGuard
TSBSUNIT tsbsUnit
TSBS tsbs
TWCUNIT twcUnit
TWCUSER twcUser
TINTUNIT tIntUnit
TINT tint
SMLCSPC sMLCSignallingPointCode
APLESSNBSC applPartSSNLCSEBSC
APLESSNSMLC applPartSSNLESMLC
SMLCPERTFLAG sMLCPeriocTestFlag
T10UNIT t10Unit
M3T10 mtl3Timer10
System Responses:
- Operation Completed
USER NAME: sag
COMMAND: Get OPC:NAME=OPC:0;
SW RELEASE: 02-06-03-01-00-04_02-05-20
COMMAND
RESULT:
OPERATION COMPLETED
SS7MTPTYP: ss7MtpType
OPC:


776 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
NetworkClusterMember: NetworkClusterMem-
ber
NetworkCluster: NetworkCluster
MSCSPC:
networkClusterMember: networkClusterMember
networkCluster: networkCluster
networkIndicator: networkIndicator
BSSAPSSN: bssapSsn
MSCPERTFLAG: mscPeriodicTestFlag
T1UNIT: MS100 (read only)
M2T1: mt12Timer1
T2UNIT: MS100 (read only)
M2T2: mt12Timer2
T3UNIT: MS100 (read only)
M2T3: mt12Timer3
T4NUNIT: MS100 (read only)
M2T4N: mt12Timer4N
T4EUNIT: MS100 (read only)
M2T4E: mt12Timer4E
T5UNIT: MS100 (read only)
M2T5: mt12Timer5
T6UNIT: MS100 (read only)
M2T6: mt12Timer6
T7UNIT: MS100 (read only)
M2T7: mt12Timer7
FLOWCTH: flowcThreshold
CONGTH: congThreshold
Sanity UNIT: MS100 (read only)
Sanity Timer: sanityTimer
ERRCORMTD: CCSS7 ErrorCorrectionMethod
N1: n1
N2: n2
T1UNIT1: MS100 (read only)
M3T1: mt13Timer1
T2UNIT1: MS100 (read only)
M3T2: mt13Timer2
T3UNIT1: MS100 (read only)


A30808-X3247-M230-6-7619

777
CML:BSC OPC
Id:0900d805800d4457
M3T3: mt13Timer3
T4UNIT: MS100 (read only)
M3T4: mt13Timer4
T5UNIT1: MS100 (read only)
M3T5: mt13Timer5
T12UNIT: MS100 (read only)
M3T12: mt13Timer12
T13UNIT: MS100 (read only)
M3T13: mt13Timer13
T14UNIT: MS100(read only)
M3T14: mt13Timer14
T17UNIT: MS100 (read only)
M3T17: mt13Timer17
T19UNIT: SEC5 (read only)
M3T19: mt13Timer19
T22OR20UNIT: SEC5 (read only)
M3T22OR20: mt13Timer22or20
T23OR21UNIT: SEC5 (read only)
M3T23OR21: mt13Timer23or21
T1TMUNIT: MS100 (read only)
M3T1TM mt13Timer1TM
T2TMUNIT SEC5 (read only)
M3T2TM mt13Timer2TM
TCONNUNIT: SEC5 (read only)
TCONN: tconn
TIASUNIT: SEC5 (read only)
TIAS: tias
TIARUNIT: SEC5 (read only)
TIAR: tiar
TRELUNIT: HLFSEC (read only)
TREL: trel
TGUARDUNIT: SEC5 (read only)
TGUARD: tGuard
TSBSUNIT: HLFSEC (read only)
TSBS: tsbs
TWCUNIT: HLFSEC (read only)


778 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
GET OPC BASICS
GET OPC MTL2
TWCUSER: twcUser
TINTUNIT: SEC5 (read only)
TINT: tint
SMLCSPC: sMLCSignallingPointCode
APLESSNBSC: applPartSSNLCSEBSC
APLESSNSMLC: applPartSSNLESMLC
SMLCPERTFLAG: sMLCPeriocTestFlag
T10UNIT: MS100 (read only)
M3T10: mtl3Timer10
NAME: name
MSCPERTFLAG: mscPeriodicTestFlag
TCONN: tconn
TIAS: tias
TIAR: tiar
TREL: trel
TGUARD: tGuard
TSBS: tsbs
TWCUSER: twcUser
TINT: tint
SMLCSPC: sMLCSignallingPointCode
APLESSNBSC: applPartSSNLCSEBSC
APLESSNSMLC: applPartSSNLESMLC
SMLCPERTFLAG: sMLCPeriocTestFlag
M3T10: mtl3Timer10
NAME: name
M2T1: mtl2Timer1
M2T2: mtl2Timer2
M2T3: mtl2Timer3
M2T4N: mtl2Timer4N
M2T4E: mtl2Timer4E
M2T5: mtl2Timer5


A30808-X3247-M230-6-7619

779
CML:BSC OPC
Id:0900d805800d4457
GET OPC MTL3
- Operation Failed
None.
Application Guidelines:
Allowed Timer Units are:
GET OPC BASICS
M2T6: mtl2Timer6
M2T7: mtl2Timer7
FLOWCTH: flowcThreshold
CONGTH: congThreshold
SANTIME: sanityTimer
ERRCORMTD: CCSS7 ErrorCorrectionMethod
N1: n1
N2: n2
NAME: name
M3T1: mtl3Timer1
M3T2: mtl3Timer2
M3T3: mtl3Timer3
M3T4: mtl3Timer4
M3T5: mtl3Timer5
M3T12: mtl3Timer12
M3T13: mtl3Timer13
M3T14: mtl3Timer14
M3T17: mtl3Timer17
M3T19: mtl3T19
M3T22OR20: mtl3T22or20
M3T23OR21: mtl3T23or21
M3T1TM: mtl3T1TM
M3T2TM: mtl3T2TM
MS100 hundred of milliseconds
SEC5 5 seconds
HLFSEC half seconds.


780 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
Allowed Timer Units are:
GET OPC MTL2
Allowed Timer Units are:
GET OPC MTL3
Allowed Timer Units are:
Example of Command Execution:
Get OPC:NAME=OPC:0,REQATTL=SS7MTPTYP&OPC&MSCSPC&NTWIND&
BSSAPSSN&MSCPERTFLAG&T1UNIT&M2T1&T2UNIT&M2T2&T3UNIT&
M2T3&T4NUNIT&M2T4N&T4EUNIT&M2T4E&T5UNIT&M2T5&T6UNIT&M2T6&
T7UNIT&M2T7&FLOWCTH&CONGTH&SANUNIT&SANTIME&ERRCORMTD&N1&
N2&T1UNIT1&M3T1&T2UNIT1&M3T2&T3UNIT1&M3T3&T4UNIT&M3T4&T5UNIT1&
M3T5& T12UNIT&M3T12&T13UNIT&M3T13&T14UNIT&M3T14&T17UNIT&M3T17&
T19UNIT&M3T19&T22OR20UNIT&M3T22OR20&T23OR21UNIT&M3T23OR21&
T1TMUNIT&M3T1TM&T2TMUNIT&M3T2TM&TCONNUNIT&TCONN&TIASUNIT&
TIAS&TIARUNIT&TIAR&TRELUNIT&TREL&TGUARDUNIT&TGUARD&TSBSUNIT&
TSBS&TWCUNIT&TWCUSER&TINTUNIT&TINT&SMLCSPC&APLESSNBSC&
APLESSNSMLC&SMLCPERTFLAG&M3T10;
GET OPC BASICS
Get OPC BASICS:NAME=OPC:0;
GET OPC MTL2
Get OPC MTL2:NAME=OPC:0;
GET OPC MTL3
Get OPC MTL3:NAME=OPC:0;
MS100 hundred of milliseconds
SEC5 5 seconds
HLFSEC half seconds.
MS100 hundred of milliseconds
SEC5 5 seconds
HLFSEC half seconds.
MS100 hundred of milliseconds
SEC5 5 seconds
HLFSEC half seconds.


A30808-X3247-M230-6-7619

781
CML:BSC OPC
Id:0900d805800d4457
GET OPC BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the timers for MTP Level 2 and Level 3
Protocol of the Common Channel Signalling System SS7.
Long Names:
NAME Addres of the managed object
SS7MTPTYP ss7MtpType
OPC originatingPointCode
MSCSPC mscSignallingPointCode
NTWIND networkIndicator
BSSAPSSN bssapSsn
MSCPERTFLAG mscPeriocTestFlag
TCONNUNIT tConnUnit
TCONN tconn
TIASUNIT tiasUnit
TIAS tias
TIARUNIT tiarUnit
TIAR tiar
TRELUNIT trelUnit
TREL trel
TGUARDUNIT tGuardUnit
TGUARD tGuard
TSBSUNIT tsbsUnit
TSBS tsbs
TWCUNIT twcUnit
TWCUSER twcUser
TINTUNIT tIntUnit
TINT tint
SMLCSPC sMLCSignallingPointCode
APLESSNBSC applPartSSNLCSEBSC
APLESSNSMLC applPartSSNLESMLC
GET OPC BASICS NAME=OPC:0..0;


782 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
SMLCPERTFLAG sMLCPeriocTestFlag
System Responses:
See GET OPC
Application Guidelines:
See GET OPC
Example of Command Execution:
See GET OPC
GET OPC MTL2
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC MTL2
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the timers for MTP Level 2 and Level 3
Protocol of the Common Channel Signalling System SS7.
Long Names:
NAME Addres of the managed object
T1UNIT t1Unit
M2T1 mtl2Timer1
T2UNIT t2Unit
M2T2 mtl2Timer2
T3UNIT t3Unit
M2T3 mtl2Timer3
T4NUNIT t4NUnit
M2T4N mtl2Timer4N
T4EUNIT t4EUnit
M2T4E mtl2Timer4E
T5UNIT t5Unit
M2T5 mtl2Timer5
T6UNIT t6Unit
M2T6 mtl2Timer6
T7UNIT t7Unit
M2T7 mtl2Timer7
GET OPC MTL2 NAME=OPC:0..0;


A30808-X3247-M230-6-7619

783
CML:BSC OPC
Id:0900d805800d4457
FLOWCTH flowcThreshold
CONGTH congThreshold
SANUNIT sanityUnit
SANTIME sanityTimer
ERRCORMTD ccss7ErrorCorrectionMethod
N1 n1
N2 n2
System Responses:
See GET OPC
Application Guidelines:
See GET OPC
Example of Command Execution:
See GET OPC
GET OPC MTL3
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC GET OPC MTL3
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the timers for MTP Level 2 and Level 3
Protocol of the Common Channel Signalling System SS7.
Long Names:
NAME Addres of the managed object
T1UNIT1 t1Unit
M3T1 mtl3Timer1
T2UNIT1 t2Unit
M3T2 mtl3Timer2
T3UNIT1 t3Unit
M3T3 mtl3Timer3
T4UNIT t4Unit
M3T4 mtl3Timer4
T5UNIT1 t5Unit
M3T5 mtl3Timer5
GET OPC MTL3 NAME=OPC:0..0;


784 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
T12UNIT t12Unit
M3T12 mtl3Timer12
T13UNIT t13Unit
M3T13 mtl3Timer13
T14UNIT t14Unit
M3T14 mtl3Timer14
T17UNIT t17Unit
M3T17 mtl3Timer17
T19UNIT t19Unit
M3T19 mtl3Timer19
T22OR20UNIT t22or20Unit
M3T22OR20 mtl3Timer22or20
T23OR21UNIT t23or21Unit
M3T23OR21 mtl3Timer23or21
T1TMUNIT t1tmUnit
M3T1TM mtl3Timert1tm
T2TMUNIT t2tmUnit
M3T2TM mtl3Timert2tm
T10UNIT t10Unit
M3T10 mtl3Timer10
System Responses:
See GET OPC
Application Guidelines:
See GET OPC
Example of Command Execution:
See GET OPC
GETINFO OPC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC GETINFO OPC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
GETINFO OPC NAME=OPC:0..0;


A30808-X3247-M230-6-7619

785
CML:BSC OPC
Id:0900d805800d4457
Links on A interface;
Links on Lb interface;
Status of MSC-SPC;
Status of SMLC-SPC;
Status of congestion of MSC;
Level of congestion of MSC;
Status of congestion of SMLC;
Level of congestion of SMLC.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO OPC ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GETINFO REPORT OPC:
NAME = OPC:0
SS7L ON AINT: 6
SS7L ON LBINT: 1
MSC-SPC STATUS: MTP_INACCESSIBLE
SMLC-SPC STATUS MTP: INACCESSIBLE
MSC CONGESTION STATUS: MTP_NOT_CONGESTED
MSC CONGESTION LEVEL: 0
SMLC CONGESTION STATUS: MTP_NOT_CONGESTED
SMLC CONGESTION LEVEL: 0
SCCP-MSC-BSSAP: SCCP_PROHIBITED
SCCP-SMLC-BSSAP-LE: SCCP_PROHIBITED
SMG-MSC-BSSAP TEST IN PROGRESS: FALSE
SMG-SMLC-BSSAP-LE TEST IN PROGRESS: FALSE
TL3-AINT SW STATE: 10
TL3-LBINT SW STATE: 10
TL3-ABIS SW STATE: 10


786 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
SCCP-AINT SW STATE: 10
SCCP-LBINT SW STATE: 10
END OF REPORT
- Operation Failed
GETINFO OPC NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack OPC:
name = OPC:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
The attribute "relatedFiles" displays only the file name without the complete BSC disk
storage path.
Example of Command Execution:
Getinfo OPC:NAME=OPC:0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

787
CML:BSC OPC
Id:0900d805800d4457
SET OPC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL OPC SET OPC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the values of the parameters that are used in the Common
Channel Signalling System (SS7).
Long Names:
NAME Addres of the managed object
MSCSPC mscSignallingPointCode
MSCPERTFLAG mscPeriocTestFlag
M2T1 mtl2Timer1
M2T2 mtl2Timer2
M2T3 mtl2Timer3
M2T4N mtl2Timer4N
M2T4E mtl2Timer4E
M2T5 mtl2Timer5
M2T6 mtl2Timer6
M2T7 mtl2Timer7
FLOWCTH flowcThreshold
CONGTH congThreshold
SANTIME sanityTimer
ERRCORMTD ccss7ErrorCorrectionMethod
N1 n1
N2 n2
M3T1 mtl3Timer1
M3T2 mtl3Timer2
SET OPC NAME=OPC:0..0 [,MSCSPC=] [,MSCPERTFLAG=]
[,M2T1=] [,M2T2=] [,M2T3=] [,M2T4N=] [,M2T4E=] [,M2T5=]
[,M2T6=] [,M2T7=] [,FLOWCTH=] [,CONGTH=] [,SAN-
TIME=] [,ERRCORMTD=] [,N1=] [,N2=] [,M3T1=] [,M3T2=]
[,M3T3=] [,M3T4=] [,M3T5=] [,M3T12=] [,M3T13=]
[,M3T14=] [,M3T17=] [,M3T19=] [,M3T22OR20=]
[,M3T23OR21=] [,M3T1TM=] [,M3T2TM=] [,TCONN=]
[,TIAS=] [,TIAR=] [,TREL=] [,TGUARD=] [,TSBS=]
[,TWCUSER=] [,TINT=] [,SMLCSPC=] [,APLESSNBSC=]
[,APLESSNSMLC=] [,SMLCPERTFLAG=] [,M3T10=];


788 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
M3T3 mtl3Timer3
M3T4 mtl3Timer4
M3T5 mtl3Timer5
M3T12 mtl3Timer12
M3T13 mtl3Timer13
M3T14 mtl3Timer14
M3T17 mtl3Timer17
M3T19 mtl3Timer19
M3T22OR20 mtl3Timer22or20
M3T23OR21 mtl3Timer23or21
M3T1TM mtl3Timert1tm
M3T2TM mtl3Timert2tm
TCONN tconn
TIAS tias
TIAR tiar
TREL trel
TGUARD tGuard
TSBS tsbs
TWCUSER twcUser
TINT tint
SMLCSPC sMLCSignallingPointCode
APLESSNBSC applPartSSNLCSEBSC
APLESSNSMLC applPartSSNLESMLC
SMLCPERTFLAG sMLCPeriocTestFlag
M3T10 mtl3Timer10
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 1, n. 2, n. 5, n. 7, n. 14,
n. 15, n. 16.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Make reference to Application Guidelines n.3, n. 4, n. 6, n. 13, n. 17.


A30808-X3247-M230-6-7619

789
CML:BSC OPC
Id:0900d805800d4457
Application Guidelines:
1. At least one field of the OPC attribute must be different from the corresponding one
of the SPC attribute.
2. In CCITT case the subfield NetworkIdentifier of MSCSPC attributes is not config-
urable, while in ANSI case it is mandatory.
3. Depending on the value of the attribute SS7MTPTYP of the CREATE command, the
subfields of MSCSPC have different ranges, as shown in the following table:
4. Depending on the value of the attribute SS7MTPTYP of OPC object the timers
(except M2T5 timer) have different ranges, as shown in the following table:
The value assigned to M2T6 timer must be lower or equal to the M3T1TM one.
UNSUCCESSFUL_LINKSET_ONE_CONNECTED
When SS7L links are configured on linkset 1 the attribute SMLCSPC
cannot be set at NULL.
ANSI CCITT
Network Cluster Member 1-255 0-255
Network Cluster 0-255 0-63
Network Identifier 1-254 NO_CONFIG
Timer Name ANSI Range CCITT Range
M2T1 129-160 400-500
M2T2 50-300 50-1500
M2T3 50-140 10-15
M2T4N 15-30 75-95
M2T4E 4-7 4-5
M2T6 10-60 30-60
M2T7 5-20 5-20


790 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
5. The following tables show the possible values for CONGTHRE and FLOWCTH
parameters and the related percentage of transmit buffer used which cause the
request of load reduction measures or the subsequently discarding of messages.
6. Depending on the value of the attribute SS7MTPTYP of OPC object, the timers
M3T22OR20 an M3T22OR21 have different ranges, as shown in the following table
7. The value assigned to M3T1TM timer must be greater or equal to the M2T6 one
(timer of OPC object).
8. If a link interruption shorter than TGUARD timer value occurs, busy CIC's will not be
released; i.e. existing speech connections will be saved. After link re-alignment
(MTP) no reset message will be sent on the A-interface. If a link interruption longer
than TGUARD timer value occurs, the existing speech connections will be released
and after link re-alignment a reset message will be sent on theA-interface. To save
existing calls for a defined period of SS7 link short time failure, the timer values at
BSC and MSC side should be equal.
9. After a TDPC SWITCH the timers TIAS and TIAR at BSC side are reset to 0. Under
disadvantageous conditions, it may happen that no inactivity test message will be
sent towards MSC for more than 2 times of the TIAS interval. To prevent that the
MSC releases the SCCP connections, the TIAR timer from the MSC should be more
than 2 times of the TIAS timer from the BSC. Please note that, if several switchs are
performed in a short period of time, the above mentioned conditions are not suffi-
cient anymore.
10. The SCCP timer TGUARD has to be set with respect to the procedure of TDPC
switch. During this switch the SS7-links at the A-interface are initialized and there-
fore timer TGUARD has to be set bigger than 30 seconds. Recommended value is
CONGTHRE (congestion control
threshold)
FLOWCTH (flow control
threshold)
value abatment onset discard value abatment onset
0 = = = 0 = =
1 45 50 not used 1 50 60
2 45 50 55 2 50 65
3 30 35 40 3 50 70
4 35 40 45 4 40 50
5 40 45 50 5 40 55
6 45 50 55 6 40 60
7 45 55
8 45 60
9 45 65
Timer Name ANSI Range CCITT Range
M3T22OR20 18-24 36-72
M3T23OR31 18-24 36-72


A30808-X3247-M230-6-7619

791
CML:BSC OPC
Id:0900d805800d4457
50 seconds. In the case TGUARD expires the BSSMAP reset procedure will be per-
formed which leads to loss of all calls. Please don't forget to set the appropriate MSC
timer accordently.
11. The timer TGUARD must be set longer than ALARMT2 (LICD object) + TSBS.
Shorter values are useless and can cause a reset procedure at A interface also for
very short link interruption due to the time needed to complete the link realignment.
The TGUARD timer is used to supervise the Adjacent Signalling Point inacessibility.
It is started when the last SS7 goes down and it is stopped only when the first link is
completely aligned. The procedure to get to the complete alignment takes the fol-
lowing steps:
if the failure lasts longer than ALARMT2 (LICD object, default 1 sec.);
at the end of the failure the PCM is up at the expiration of the timer ALARMT1
(LICD object, default 20 sec.);
after M3T17 (default 1 sec.) plus M2T4E (default 500 ms.) the level 2 is in
service;
the SLTM - SLTA message are exchanged between the 2 network elements;
after that the SST - SSA messages are exchanged between BSC and MSC also
the SCCP is aligned.
The BSC send the SST message when receives the SST from MSC or when the
TSBS timer expires. The alignment procedure is considered completed and the
timer TGUARD is stopped, only after receiving the SSA from the MSC.
12. As during TDPC switch SS7 links are initialized, it is recommandable to set
TGUARD at a value of 50 secs in order to allow proper behaviour during load con-
ditions too.
13. Depending on the value of the attribute SS7MTPTYP some timers of the OPC object
have different ranges, as shown in the following table:
14. OPC, MSCSPC and SMLCSPC attributes must differ from each other in at least one
field.
15. In CCITT case the subfield NetworkIdentifier of OPC, MSCSPC and SMLCSPC
attributes is not configurable, while in ANSI case it is mandatory.
16. If the attribute SS7MTPTYP is set to ANSI, the attributeNetworkCluster cannot
assume value 0 if 0<NIDEN<6.
17. Depending on the value of the attribute SS7MTPTYP the subfields of the attributes
OPC, MSCSPC and SMLCSPC have different ranges, as shown in the following
table:
Parameter ANSI CCITT
TCONN 1-72 0-255
TIAS 60-120 0-255
TIAR 132-255 0-255
TREL 20-40 0-255
ANSI CCITT


792 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4457
OPC
18. Before setting the ERRCORMTD parameter at
PREVENTIVE_CYCLIC_RETRANS_ERR_CORR value the SS7L object must be
put in LOCKED state.
Example of Command Execution:
Set OPC:NAME=OPC:0,MSCSPC=2-4-8,MSCPERTFLAG=FALSE,
M2T1=400,M2T2=50,M2T3=10,
M2T4N=75,M2T4E=4,M2T5=1,M2T6=30,M2T7=5,FLOWCTH=0,CONGTH=0,SANI-
TIME=0, ERRCORMTD=BASIC_ERROR_CORRECTION,N1=110,
N2=2000,TCONN=0,TIAS=0,TIAR=0,TREL=0, TGUARD=0,TSBS=0,TWCUSER=0,
TINT=0,SMLCSPC=1-23-3,APLESSNBSC=<DEFAULT>, APLESSNS-
MLC=<DEFAULT>,SMLCPERTFLAG=TRUE,M3T10=<DEFAULT>;
Network Cluster Member 1-255 0-255
Network Cluster 0-255 0-63
Network Identifier 1-254 NO_CONFIG


A30808-X3247-M230-6-7619

793
CML:BSC PCMA
Id:0900d805800d4293
PCMA
The PCMA object represents one of the PCM lines from/to MSC (A interface), departing
from the TRAU.
CREATE PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA CREATE PCMA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a 2 Mbit PCM line on the "A" interface (PCMA) specifying its
parameters. It associates a PCMA with a given PCMT identified by the Transcoder and
Rate Adapter Unit (TRAU) number and the circuit number.
Long Names:
NAME Addres of the managed object
PCMT pcmt
CRC crc
CODE code
NUA nua
BER ber
BAF baf
HCICN hCICN
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
DEFPOOLTYP defPoolType
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE PCMA NAME=PCMA:0..191 ,PCMT= [,CRC=] [,CODE=] [,NUA=]
[,BER=] [,BAF=] [,HCICN=] [,LOWBER=] [,REMAL=] [,DEF-
POOLTYP=];
OBJECT_ALREADY_EQUIPPED


794 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
Application Guidelines:
1. No PCM line has to be connected to the circuit number "circn" of TRAU.
2. The HCIC attribute value has to be a unique identifier for a PCM line on the "A"
interface.
3. After the creation of the object, the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
4. The attribute REMAL can be set only with the PCM24 lines (parameter "Pcm Type"
of the BSC object).
5. The value assigned to LOWBER attribute must be greater or equal to the BER one.
This means that the bit error rate for LOWBER is lower or equal than BER one.
E.g. LOWBER=3 , BER=2.
6. The attributes CODE, NUA and BAF can be set only with the PCM30 lines (param-
eter PCMTYPE of BSC object).
7. The HCICN attribute cannot assume a value greater than 2047 if the attribute
CICFM of the BSC object is set at GSM.
8. For PCM24 lines, the LOWBER threshold can be configured not depending on the
type of line interface cards that are being used.However, the alarm for exceeded
LOWBER canbe detected only by the MSCI V2 (on TRAU side, for the PCMA). Nev-
ertheless, if these cards are not of the correct edition, there will not be any misbe-
haviour, except for the fact that, on the network element where the line
interface cards is not able to handle this alarm, the related error messages will never
be sent to LMT and OMC.
9. When pooling is disabled DEFPOOLTYP attribute cannot be set.
10. If TRAU is AMR the attribute DEFPOOLTYP must be set at POOL_23 or POOL_46,
and if TRAU is not AMR the attribute DEFPOOLTYP must not be set at POOL_23
or POOL_46.
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The TRAU object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 1, n. 2, n. 4, n. 5, n. 6,
n. 7, n. 9, n. 10, n. 11.
UNSUCCESSFUL_INVALID_STATUS
Before creating a PCMA, the relative TRAU object instance must be
in LOCKED state.
NOT_ENOUGH_SUBSLOTS_IN_PCMS
In order to create a PCMA there must be enough PCMS sublots still
unmapped to fulfill the request of the new PCMA, depending on the
DEFPOOLTYP attribute.


A30808-X3247-M230-6-7619

795
CML:BSC PCMA
Id:0900d805800d4293
11. If TRAU is not S3 (fourth digit of EXPSWV attribute is not '03'), the attribute DEF-
POOLTYP cannot assume the values from POOL_24 to POOL_35 and the values
POOL_47 and POOL_48.
Example of Command Execution:
if PCM30:
Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,CODE=AMI,NUA=TRUE,
BER=E10_3,BAF=254,HCICN=5,LOWBER=E10_3,DEFPOOLTYP=POOL_1;
if PCM24:
Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,BER=E10_3,HCICN=5,
LOWBER=E10_3,REMAL=CCITT,DEFPOOLTYP=POOL_1;
if CICFM=NOTSTRUCT:
Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,BER=E10_3,HCICN=2600,
LOWBER=E10_3,REMAL=CCITT,DEFPOOLTYP=POOL_1;
if CICFM=GSM:
Create PCMA:NAME=PCMA:2,PCMT:0-3,CRC=FALSE,BER=E10_3,HCICN=500,
LOWBER=1,REMAL=CCITT,DEFPOOLTYP=POOL_1;
DELETE PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA DELETE PCMA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a 2 Mbit PCM line on the "A" interface (PCMA) previously
created through the CREATE PCMA command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
DELETE PCMA NAME=PCMA:0..191;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


796 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
Application Guidelines:
None.
Example of Command Execution:
Delete PCMA:NAME=PCMA:2;
GET PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A"
interface previously created through the CREATE PCMA command.
Long Names:
NAME Addres of the managed object
PCMT pcmt
CRC crc
CODE code
NUA nua
BER ber
BAF baf
HCICN hCICN
LOWBER lowerBitErrorRate
UNSUCCESSFUL_LINK_CONNECTED
No signalling link (O&M, SS7) has to be implemented on
the PCM line.
Every NUC instance related to the PCM line must be
deleted before.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a PCMA, the relative object instance
must be in LOCKED state.
Before deleting a PCMA, the relative TRAU object
instance must be in LOCKED state.
GET PCMA NAME=PCMA:0..191 [,REQATTL= PCMT ,CRC ,CODE
,NUA ,BER ,BAF ,HCICN ,LOWBER ,REMAL ,DEFPOOL-
TYP ,TOPOREL];


A30808-X3247-M230-6-7619

797
CML:BSC PCMA
Id:0900d805800d4293
REMAL remoteAlarmType
DEFPOOLTYP defPoolType
TOPOREL topologicalRelationship
System Responses:
- Operation Completed
GET PCMA BASICS
GET PCMA PCM24
NAME: name
PCMT:
Traun: traun
Circn: circn
CRC: crc
CODE: code for PCM24 line No-Config is displayed
NUA: nua for PCM24 line No-Config is displayed
BER: ber
BAF: baf for PCM24 line No-Config is displayed
HCICN: hCICN
LOWBER: lowerBitErrorRate
REMAL: remoteAlarmType for PCM30 line No-Config is displayed
DEFPOOLTYP: defPoolType
TOPOREL
:
topologicalRelationship
NAME: name
PCMT:
Traun: traun
Circn: circn
CRC: crc
BER: ber
HCICN: hCICN
LOWBER: lowerBitErrorRate
DEFPOOLTYP: defaultPoolType
NAME: name


798 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
GET PCMA PCM30
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET PCMA BASICS
None.
GET PCMA PCM24
None.
GET PCMA PCM30
None.
Example of Command Execution:
Get PCMA:NAME=PCMA:0,REQATTL=PCMT&CRC&CODE&NUA&BER&BAF&
HCICN&LOWBER&REMAL&DEFPOOLTYP&TOPOREL;
GET PCMA BASICS
Get PCMA BASICS:NAME=PCMA:0;
GET PCMA PCM24
Get PCMA PCM24:NAME=PCMA:0;
GET PCMA PCM30
Get PCMA PCM30:NAME=PCMA:0;
REMAL: remoteAlarmType
NAME: name
CODE: code
NUA: nua
BAF: baf
NOT_EQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

799
CML:BSC PCMA
Id:0900d805800d4293
GET PCMA BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A"
interface previously created through the CREATE PCMA command.
Long Names:
NAME Addres of the managed object
PCMT pcmt
CRC crc
BER ber
HCICN hCICN
LOWBER lowerBitErrorRate
DEFPOOLTYP defPoolType
TOPOREL topologicalRelationship
System Responses:
See GET PCMA
Application Guidelines:
See GET PCMA
Example of Command Execution:
See GET PCMA
GET PCMA PCM24
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA PCM24
Applicability:
Phase 2.
Visibility level: 0.
GET PCMA BASICS NAME=PCMA:0..191;
GET PCMA PCM24 NAME=PCMA:0..191;


800 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A"
interface previously created through the CREATE PCMA command.
Long Names:
NAME Addres of the managed object
REMAL remoteAlarmType
System Responses:
See GET PCMA
Application Guidelines:
See GET PCMA
Example of Command Execution:
See GET PCMA
GET PCMA PCM30
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA PCM30
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A"
interface previously created through the CREATE PCMA command.
Long Names:
NAME Addres of the managed object
CODE code
NUA nua
BAF baf
System Responses:
See GET PCMA
Application Guidelines:
See GET PCMA
Example of Command Execution:
See GET PCMA
GET PCMA PCM30 NAME=PCMA:0..191;


A30808-X3247-M230-6-7619

801
CML:BSC PCMA
Id:0900d805800d4293
GET PCMA STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GET PCMA STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PCMA object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get PCMA STAT:NAME=PCMA:0;
GETINFO PCMA
GET PCMA STAT NAME=PCMA:0..191;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO PCMA NAME=PCMA:0..191;


802 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GETINFO PCMA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the PCMA: AST, OST, AVS, CST.
2. The identity of the SS7, X25A signalling timeslot on the PCMA line.
3. The identity of the NUC timeslot on the PCMA line.
4. The identity of the FRL timeslot on the PCMA line.
5. The total number of traffic channels.
6. The number of idle and busy traffic channels.
7. The PCMT connected with this PCMA.
8. For each timeslot (TSLA) the POOL TYPE associated.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO PCMA ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT PCMA:
NAME = PCMA:0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
SS7L TIMESLOT: 16 29
X25A TIMESLOT: NONE
NUC TIMESLOT: 1 7 9
FRL TIMESLOT: 2 6 8
TRAFFIC CH (TOTAL): 27
TRAFFIC CH BUSY: 0
TRAFFIC CH IDLE: 27


A30808-X3247-M230-6-7619

803
CML:BSC PCMA
Id:0900d805800d4293
PCMT: 0 - 0
TSLA NR POOL TYPE
1 POOL_1
2 NOT DEFINED
... ... ... ...
31 NOT DEFINED
END OF REPORT
- Operation Failed
GETINFO PCMA NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PCMA:
name = PCMA:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo PCMA:NAME=PCMA:0;
GETRELATIONSHIP PCMA
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
PCMA
NAME=PCMA:0..191;


804 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GETRELATIONSHIP PCMA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the PCMA object the related HMOs are the following: LICD/LICDS, EPWR, BSMS,
TPWR, PWRD, MPCC, TDPC, MEMT, NTW and PPXL.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PCMA:NAME=PCMA:0;
GETSUBO PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA GETSUBO PCMA
Applicability:
Phase 2.
Visibility level: 0.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO PCMA NAME=PCMA:0..191;


A30808-X3247-M230-6-7619

805
CML:BSC PCMA
Id:0900d805800d4293
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PCMA:NAME=PCMA:0;
LOCK PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA LOCK PCMA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK PCMA NAME=PCMA:0..191;


806 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PCMA:NAME=PCMA:0;
SHUTDOWN PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA SHUTDOWN PCMA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The system attempts to perform the command, every 10 seconds for the next 6 minutes.
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SHUTDOWN PCMA NAME=PCMA:0..191;


A30808-X3247-M230-6-7619

807
CML:BSC PCMA
Id:0900d805800d4293
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 6 minutes and 10
seconds ----------> LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown PCMA:NAME=PCMA:1;
UNLOCK PCMA
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)
UNLOCK PCMA NAME=PCMA:0..191;


808 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4293
PCMA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA UNLOCK PCMA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Unlocking of BTSM causes a full BTS alignment.
Example of Command Execution:
Unlock PCMA:NAME=PCMA:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

809
CML:BSC PCMB
Id:0900d805800d464e
PCMB
The PCMB object represents one of the PCM lines from/to BTSE (Abis interface).
CREATE PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB CREATE PCMB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a 2 Mbit PCM line on the "A-bis" interface (PCMB) specifying its
parameters. It associates a PCMB with a given PCML identified by the LICD number and
the circuit number.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LREDUNEQ lineRedundancyEquipped
L1CTS layer1ControlTimeslot
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
WMOD workingMode
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE PCMB NAME=PCMB:0..117 ,PCML= [,CRC=] [,CODE=] [,NUA=]
[,BER=] [,BAF=] ,LREDUNEQ= [,L1CTS=] [,LOWBER=]
[,REMAL=] [,WMOD=];
OBJECT_ALREADY_EQUIPPED


810 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
Application Guidelines:
1. One PCMB is connected to one BTSM (STAR configuration) or several BTSMs
(Multidrop orLoop configuration) and the mapping between Physical Radio Channel
and Terrestrial Time Slot, on the "A-bis" interface, is configured by the operator in
accordance to the CREATE CHAN command.
2. All parameters without default values are mandatory.
3. After the creation of the object, the ADMINISTRATIVE state of this object is set to
LOCKED.
4. The attribute REMAL can be set only with the PCM24 lines (parameter PCMTYPE
of BSC object).
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The LICD object instances must be already equipped.
UNSUCCESSFUL_LINK_CONNECTED
The trunk of the LICD card corresponding to the referenced
line cannot be already connected to a PCM line. If the PCMB
line works in Double Trunk Mode both trunk must be free (i.e
no PCM line connected to that LICD circuit), while if the PCMB
line works in Single Trunk Mode, the relative trunk of LICD
circuit must be free (i.e no PCMB in Single Trunk mode with
the same LREDUNEQ and no other PCM in Double Trunk
Mode).
In order to connect two PCMB lines to a same LICD circuit,
both PCMBs must be in Single Trunk Mode and LREDUNEQ
attribute must be SIMPLEXA for one PCMB and SIMPLEXB
for the other.
UNSUCCESSFUL_VAR_OUT_RANGE
If the field TSL of the L1CTS attribute is set, also the filed SSL
must be set.The L1CTS attribute value must be different from
the related BTSM O&M signalling link.
UNSUCCESSFUL_INVALID_TIME_SLOT
The value assigned to the TimeslotN field of the L1TS attribute
is not compatible with the PCM line type attribute (parameter
PCMTYPE of BSC object).
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 4, n. 5, n. 6, n. 9.
UNSUCCESSFUL_WRONG_LICD_CARD
If the network card is different from SNAP_STLP the circuit of
the PCML cannot be greater than 3.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
The maximum number of configurable PCM lines (PCMB +
PCMG + PCMS) is 72 with old MPCC or old BSC rack type.


A30808-X3247-M230-6-7619

811
CML:BSC PCMB
Id:0900d805800d464e
5. The value assigned to LOWBER attribute must be greather or equal to the BER one.
This means that the bit error rate for LOWBER is lower or equal than the BER one.
For example:
6. The attributes CODE, NUA and BAF can be set only with the PCM30 lines (param-
eter "Pcm Type" of BSC object).
7. For PCM24 lines, the LOWBER threshold can be configured not depending on the
type of line interface cards that are being used. However, the alarm of the exceeded
LOWBER can be detected only by the QTLP V2 (on the BSC side, for PCMB). Nev-
ertheless, if these cards are not of the correct edition, there will not be any misbe-
haviour, except for the fact that, on the network element where the line
interface card is not able to handle this alarm, the related error messages will never
be sent to LMT and OMC.
8. When the L1CTRLTS (layer1ControlTS) parameter is set at the same value as the
abisChannel of the BTSM (O&M signalling link), L1CTS parameter, the BTS is out
of service and can no more be accessed via RC or BSC (Abis link).
The attribute L1CTRLTS has then to be changed via BTSE-LMT (directly connected
at BTSE site).
9. The WMOD attribute can be set at SINGLE_TRUNK only if the PCMB attribute
LREDUNEQ is not set at DUPLEX.
Example of Command Execution:
For PCM30:
Create PCMB:NAME=PCMB:0,PCML=0-0,CRC=FALSE,CODE=HDB3,
NUA=FALSE, BER=E10_3,BAF=0,LREDUNEQ=DUPLEX,L1CTS=1-2,
LOWBER=E10_3;
DELETE PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB DELETE PCMB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a 2 Mbit PCM line on the "A-bis" interface (PCMB) previously
created through the CREATE PCMB command.
LOWBER = 3 (10-6 bit error rate)
BER = 2 (10-5 bit error rate).
DELETE PCMB NAME=PCMB:0..117;


812 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete PCMB:NAME=PCMB:0;
GET PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GET PCMB
Successful
DELETE NACK:
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_LINK_CONNECTED
No O&M signalling link must be implemented on the instance
"pcmbn" of the pcmb line.
Every NUC instance related to the PCM line must be deleted
defore.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a PCMB, the relative object instance must be in
LOCKED state.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The PCMB lines cannot be connected as PCMCON1 to any BTSM
object.
GET PCMB NAME=PCMB:0..117 [,REQATTL= PCML ,CRC ,CODE
,NUA ,BER ,BAF ,LREDUNEQ ,L1CTS ,LOWBER ,REMAL
,WMOD];


A30808-X3247-M230-6-7619

813
CML:BSC PCMB
Id:0900d805800d464e
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A-bis"
interface (PCMB) previously created through a CREATE PCMB command.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LREDUNEQ lineRedundancyEquipped
L1CTS layer1ControlTimeslot
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
WMOD workingMode
System Responses:
- Operation Completed
NAME: name
PCML: pcmLine
CRC: crc
CODE: code for PCM24 line No-Config is displayed
NUA: nua for PCM24 line No-Config is displayed
BER: ber
BAF: baf for PCM24 line No-Config is displayed
LRE-
DUNEQ:
lineRedundancyEquipped
L1CTS: layer1ControlTimeslot
LOWBER: lowerBitErrorRate
REMAL: remoteAlarmType
WMOD: workingMode


814 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
GET PCMB BASICS
GET PCMB PCM24
GET PCMB PCM30
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET PCMB BASICS
None.
GET PCMB PCM24
NAME: name
CRC: crc
CODE: code for PCM24 line No-Config is displayed
NUA: nua for PCM24 line No-Config is displayed
BER: ber
BAF: baf for PCM24 line No-Config is displayed
LRE-
DUNEQ:
lineRedundancyEquipped
L1CTS: layer1ControlTimeslot
LOWBER: lowerBitErrorRate
REMAL: remoteAlarmType
NAME: name
REMAL: remoteAlarmType
NAME: name
CODE: code for PCM24 line No-Config is displayed
NUA: nua for PCM24 line No-Config is displayed
BAF: baf for PCM24 line No-Config is displayed
NOT_EQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

815
CML:BSC PCMB
Id:0900d805800d464e
None.
GET PCMB PCM30
None.
Example of Command Execution:
Get PCMB:NAME=PCMB:0,REQATTL=PCML&CRC&CODE&NUA&BER&BAF&
LREDUNEQ&L1CTS&LOWBER&REMAL&WMOD;
GET PCMB BASICS
Get PCMB BASICS:NAME=PCMB:0;
GET PCMB PCM24
Get PCMB PCM24:NAME=PCMB:0;
GET PCMB PCM30
Get PCMB PCM30:NAME=PCMB:0;
GET PCMB BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GET PCMB BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A-bis"
interface (PCMB) previously created through a CREATE PCMB command.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
BER ber
LREDUNEQ lineRedundancyEquipped
L1CTS layer1ControlTimeslot
LOWBER lowerBitErrorRate
WMOD workingMode
GET PCMB BASICS NAME=PCMB:0..117;


816 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
System Responses:
See GET PCMB
Application Guidelines:
See GET PCMB
Example of Command Execution:
See GET PCMB
GET PCMB PCM24
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GET PCMB PCM24
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A-bis"
interface (PCMB) previously created through a CREATE PCMB command.
Long Names:
NAME Addres of the managed object
REMAL remoteAlarmType
System Responses:
See GET PCMB
Application Guidelines:
See GET PCMB
Example of Command Execution:
See GET PCMB
GET PCMB PCM30
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GET PCMB PCM30
Applicability:
Phase 2.
Visibility level: 0.
GET PCMB PCM24 NAME=PCMB:0..117;
GET PCMB PCM30 NAME=PCMB:0..117;


A30808-X3247-M230-6-7619

817
CML:BSC PCMB
Id:0900d805800d464e
Command Description:
This command is used to retrieve the parameters of a 2 Mbit PCM line on the "A-bis"
interface (PCMB) previously created through a CREATE PCMB command.
Long Names:
NAME Addres of the managed object
CODE code
NUA nua
BAF baf
System Responses:
See GET PCMB
Application Guidelines:
See GET PCMB
Example of Command Execution:
See GET PCMB
GET PCMB STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GET PCMB STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PCMB object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
GET PCMB STAT NAME=PCMB:0..117;


818 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get PCMB STAT:NAME=PCMB:0;
GETINFO PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETINFO PCMB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The "report complete" indicator
2. The states and statuses of the PCMB: AST, OST, AVS, CTS.
3. The Working Mode.
4. The LICD number and LICD circuit which the PCMB line is connected to.
5. The BTSMs connected with this PCMB line.
6. For both trunks: if equipped, the number of rising edges and the possible presence
for each type of alarms.
7. For each link on the PCMB line its rate in kbits/s (16 or 64)
8. The missing timeslots list
9. For each channel on the PCMB line its rate in kb/s (64 or 16 kbits/s).
10. A timeslot map, that summarizes all the objects/attributes (SUBTSLBs, NUC,
LPDLM) configured on PCMB timeslots.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT PCMB: <BSS ID> <PCMB NR> 11:41:14 22/03/1999
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO PCMB NAME=PCMB:0..117;


A30808-X3247-M230-6-7619

819
CML:BSC PCMB
Id:0900d805800d464e
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
WORKING MODE: DOUBLE TRUNK
LICD CONNECTED: 0-0
BTSM CONNECTED: 0 49 78
TRUNK A EQUIPPED: TRUE
PCM-TRUNK-A ALARMS NR.OF RISING EDGES ALARM PRESENT
AIS 0 FALSE
CEERAL 0 FALSE
RAI 1 TRUE
EER 0 FALSE
LFA 1 FALSE
LOS 1 TRUE
LCAAL 0 FALSE
RNUA 0 FALSE
LNUA 0 FALSE
B5 0 FALSE
TXAL 0 FALSE
LBER 0 FALSE
SLIP 0 FALSE
L1CTS 1 FALSE
TRUNK B EQUIPPED: TRUE
PCM-TRUNK-B ALARMS NR.OF RISING EDGES ALARM PRESENT
AIS 0 FALSE
CEERAL 0 FALSE
RAI 1 TRUE
EER 0 FALSE
LFA 1 FALSE
LOS 1 FALSE
LCAAL 0 FALSE
RNUA 0 FALSE


820 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
LNUA 0 FALSE
B5 0 FALSE
TXAL 0 FALSE
LBER 0 FALSE
SLIP 0 FALSE
L1CTS 0 FALSE
16 KBIT/S TIMESLOTS:
2 3 5 6 7 8 9 10 11 12 13 14 15 17
19 20 21 23 24 25 26 27 28 30 31
64 KBIT/S TIMESLOTS:
1 16 18 29
MISSING TIMESLOTS:
1 2 31
TIMESLOT MAP:
TS SUBSLOT 0 SUBSLOT 1 SUBSLOT 2 SUBSLOT 3
1 STLSB 1-0 STLSB 1-1 STLSB 1-2 STLSB 1-3
2 STLSB 2-1 STLSB 2-2 STLSB 2-3
...;
28
29 LPDLM 2-1
30 STLSB 30-0
31 STLSB 31-2 STLSB 31-3
END OF REPORT
- Operation Failed
GETINFO PCMB NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PCMB:
name = PCMB:0
nackCause = <nack cause>


A30808-X3247-M230-6-7619

821
CML:BSC PCMB
Id:0900d805800d464e
NACK CAUSES:
Application Guidelines:
1. The standard alarms, specified in the GSM recommendations, are the following:
AIS: Alarm Indication Signal
CEERAL: CRC Excessive Error Rate (only QTLP V1)
RAI: Remote Alarm Indication
EER: Excessive Error Rate
LFA: Loss Of Frame Alignment
LOS: Loss Of Signal
LCAAL: Loss of CRC Alignment (only QTLP V1)
LBER: Low BER threshold exceeded (only QTLP V2 and STLP)
SLIP: Slip alarm (some PCM frames are lost - only QTLP V2 and STLP)
As it can be seen, not all the types of LICD (QTLP V1 and V2) handle some of these
alarms.
2. The following alarm can be considered proprietary of BSC, and is present only for
QTLP V1:
TXAL (Transmission Alarm - only QTLP V1)
The TX alarm is an internal alarm, and reveals a parity alarm on the bit stream that
is sent by the switching matrix to the LICD.
3. The L1CTS alarm (Layer 1 Control Time Slot) means that the pattern received by
the BSC on the Layer 1 Control Time Slot is different from the pattern that the BSC
has sent to the BTS on the same time slot (this pattern is 0x01).
This alarm can arise when a remote interruption, which occurs in the external
network, is not detected by means of the standard alarms, due to the fact that the
network is not transparent for the time slot 0.
This alarm is handled only for the PCMB lines, for which the Layer 1 Control Time
Slot can be configured in the BSC database. The filtering mechanism for declaring
the error rising and ceasing is the same of the other PCM alarms, and uses the
ALARMT1 and ALARMT2 parameters of the LICD object (but does not use the
ALARMT3 and ALACOUNT).
4. The alarm counters are notified to MPCC by the firmware of the LICD, and they are
zeroed when a BSC initialization occurs (full or bring up), when the PCM line is
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


822 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
created and when there is a switch of the LICD (from LICD to LICDS or vice versa).
The only exceptions are the counters of the SLIP and L1CTS alarms, which are
managed by the software of MPCC, and are independent from the LICD which the
PCMB is working on. So these two counters are not reset after a switch of LICD.
5. The SLIP alarm, unlikely than the other alarms, is a spot event rather than an alarm
state. A "slip" in fact means the loss of one or more layer 1 frames due to the missing
synchronization between the two network elements.
The "presence" of the SLIP alarm is declared by the MPCC software when 3 frames
are lost in an hour, and the alarm disappears when no frames are lost in 20 minutes.
For the SLIP alarm the counter has the meaning of "number of lost frames since the
last BSC initialization or since the creation of the PCM line".
6. For the QTLP V2 with a FW version older than SBS-QF-3-1-06-00, in order to be
sure that the counters of the alarms different from L1CTS and SLIP are reset after
a switch of LICD, or after a PCM creation, it is necessary to send, before the switch,
a "perform test" command for the LICD or LICDS that is going in service. This is
because the older FW versions reset the counters only when the LICD board is
reset.
Example of Command Execution:
Getinfo PCMB:NAME=PCMB:0;
GETREDSTAT PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETREDSTAT PCMB
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the State of the links and the configuration of the active
channels (received from link A or from link B of the PCM line). This command can be
applied to the PCMB lines configured in duplex mode.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETREDSTAT PCMB NAME=PCMB:0..117;
Successful
LKAPCM This attribute is meaningless for the Managed Object
PCMB.
LKSPCM This attribute represents the State of the link


A30808-X3247-M230-6-7619

823
CML:BSC PCMB
Id:0900d805800d464e
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get PCMB REDSTAT:NAME=PCMB:1;
GETRELATIONSHIP PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETRELATIONSHIP PCMB
Applicability:
Phase 2.
Visibility level: 1.
Validity range:
linkStatePcm linkAandBOk
linkAnotOk
linkBnotOk
bothNotOk
LKCONFPCM This attribute represents the current bit selection.
It is meaningful only for PCMB linesBinary values repre-
senting the source of data in the PCM line. If the i-th bit is
0 then the i-th channel is receiving data from link A; other-
wise from link B. Data will be shown as follows: 7-0
0011001015-8 ..... 127-120 ....
INVALID_COMMAND
The syntax of the message received from LMT is incor-
rect.
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PCML_DISABLED_DEPENDENCY
The line is disabled because LICD is unavailable, so it can
not be monitored.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The line is configured as simplex.
GETRELATIONSHIP
PCMB
NAME=PCMB:0..117;


824 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the PCMB object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT and NTW.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PCMB:NAME=PCMB:0;
GETSUBO PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB GETSUBO PCMB
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO PCMB NAME=PCMB:0..117;


A30808-X3247-M230-6-7619

825
CML:BSC PCMB
Id:0900d805800d464e
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PCMB:NAME=PCMB:0;
LOCK PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB LOCK PCMB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK PCMB NAME=PCMB:0..117;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


826 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state LOCKED will survive at the Full Init (and consequently to
the load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PCMB:NAME=PCMB:0;
SET PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB SET PCMB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies a 2 Mbit PCM line LREDUNEQ parameter on the
"A-bis" interface (PCMB).
Long Names:
NAME Addres of the managed object
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LREDUNEQ lineRedundancyEquipped
L1CTS layer1ControlTimeslot
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
System Responses:
- Operation Completed
Successful
- Operation Failed
SET PCMB NAME=PCMB:0..117 [,CRC=] [,CODE=] [,NUA=] [,BER=]
[,BAF=] [,LREDUNEQ=] [,L1CTS=] [,LOWBER=]
[,REMAL=];


A30808-X3247-M230-6-7619

827
CML:BSC PCMB
Id:0900d805800d464e
NACK CAUSES:
Application Guidelines:
1. This command fails if all concerned A-bis channels are busy.
2. The attribute BAF can be set only with the PCM30 lines (parameter "Pcm Type" of
BSC object).
3. The attribute REMAL can be set only with the PCM24 lines (PCMTYPE attribute of
BSC object).
4. The attribute CODE and NUA can be set only with the PCM30 lines (parameter
"Pcm Type" of BSC object.
5. The value assigned to LOWBER attribute must be greater than or equal to the BER
one. This means that the bit error rate for LOWBER is lower or equal than the BER
one. For example LOWBER=3(10-6 bit error rate), BER=2(10-5 bit error rate).
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
INVALID_COMMAND
The LREDUNEQ attribute can be changed only from SIM-
PLEXA/SIMPLEXB to DUPLEX. No other changes are
allowed.
UNSUCCESSFUL_INVALID_STATUS
When the attributes BAF and CRC4 are changed the PCMB
must be in the LOCKED state.
Setting of CODE attribute is allowed only if the PCMB is in
LOCKED status.
UNSUCCESSFUL_VAR_OUT_RANGE
The field SubSlotN of the attribute L1CTS cannot be
omitted if the field TimeSlotN is set.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The time slot assigned to the L1CTS attributes is already
allocated.
The timeslot chosen for L1CTS is already used by a NUC
link.
The timeslot chosen for L1CTS is already used by a
SUBTSLB object.
UNSUCCESSFUL_INVALID_TIME_SLOT
The value assigned to the TimeslotN field of the
L1CTRLTS1 attribute is not compatible with the PCM line
type attribute (parameter PCMTYPE of BSC object).
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 2, n. 3, n. 4, n.
5, n. 7.


828 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d464e
PCMB
6. If the PCMB is connected to a BTSM as PCMCON1, then a SET PCMB command
removing the Layer 1 Control Timeslot is forbidden.
7. If the PCMB is connected to any BTSM as PCMCON1, then a SET PCMB changing
the redundancy configuration from SIMPLEX to DUPLEX is forbidden.
8. When the L1CTRLTS (layer1ControlTS) parameter is set at the same value as the
abisChannel of the BTSM (O&M signalling link), L1CTS parameter, the BTS is out
of service and can no more be accessed via OMC or BSC (Abis link).
The attribute L1CTRLTS has then to be changed via BTSE-LMT (directly connected
at BTSE site).
Example of Command Execution:
For PCM30:
Set PCMB:NAME=PCMB:0,CRC=FALSE,BAF=1, LREDUNEQ=DUPLEX,
L1CTS=1-2, CODE=HDB3,NUA=FALSE,BER=E10_3,LOWBER=E10_3;
For PCM24:
Set PCMB:NAME=PCMB:0, CRC=FALSE, LREDUNEQ=DUPLEX, L1CTS=1-2,
BER=E10_3,LOWBER=E10_3;
UNLOCK PCMB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB UNLOCK PCMB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNLOCK PCMB NAME=PCMB:0..117;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

829
CML:BSC PCMB
Id:0900d805800d464e
Application Guidelines:
None.
Example of Command Execution:
Unlock PCMB:NAME=PCMB:0;
The object instance must be already equipped.


830 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
PCMG
The PCMG functional object represents the direct physical connection between BSC
and SGSN. This line carries 32 time slots of 64 kbit/s that can handle a maximum of 31
FRLs and it can be connected to a single circuit of LICD.
The PCMG cannot be redounded. Therefore, unlike the PCMB and PCMS, it does not
have the parameter LREDUNEQ. If ASUBENCAP (BSC parameter) is TRUE, then it is
possible to create another PCMG or PCMS in the unused trunk (A or B) of the same
PCML of the PCMG. Instead, if ASUBENCAP is FALSE, the PCMG takes busy both
trunks A and B of the PCML.
CREATE PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG CREATE PCMG
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the PCMG object class. It can be done only if the
LICD is created. Creation of PCMG line means to associate a specific LICD port to a Gb
interface connection.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
System Responses:
- Operation Completed
Successful
- Operation Failed
CREATE PCMG NAME=PCMG:0..31 ,PCML= [,CRC=] [,CODE=] [,NUA=]
[,BER=] [,BAF=] [,LOWBER=] [,REMAL=];


A30808-X3247-M230-6-7619

831
CML:BSC PCMG
Id:0900d805800d4299
NACK CAUSES:
Application Guidelines:
After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
Example of Command Execution:
For PCM30:
Create PCMG:NAME=PCMG:0,PCML=0-0-A,CRC=FALSE,CODE=HDB3,
NUA=FALSE,BER=0,BAF=0;
For PCM24:
Create PCMG:NAME=PCMG:3,PCML=1-2-A,CRC=FALSE,CODE=HDB3,
NUA=FALSE,BER=0,BAF=0,LOWBER=0,REMAL=CCITT;
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The LICD object instances must be already equipped.
UNSUCCESSFUL_LINK_CONNECTED
The TRUNK of the LICD card corresponding to the referenced line
must not be already connected to a PCM line.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
The maximum number of configurable PCM lines (PCMB + PCMG
+ PCMS) is 72 with old MPCC or old BSC rack type.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The attributes REMAL can be set only with the PCM24 lines
(parameter PCMTYPE of BSC object).
The value assigned to LOWBER attribute must be greater or equal
to the BER one. This means that the bit error rate for LOWBER is
lower or equal than the BER one. For example: LOWBER = 3 (10-
6 bit error rate) BER = 2 (10-5 bit error rate).
The attributes CODE, NUA and BAF can be set only with the
PCM30 lines (parameter "Pcm Type" of BSC object).
UNSUCCESSFUL_WRONG_LICD_CARD
If the network card is different from SNAP_STLP the circuit of the
PCML cannot be greater than 3.


832 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
DELETE PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG DELETE PCMG
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the PCMG object class. It can
be done only if all FRL attached to considered PCMG are deleted.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete PCMG:NAME=PCMG:0;
GET PCMG
DELETE PCMG NAME=PCMG:0..31;
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a PCMG, the relative object instance must be in
LOCKED state.
SUBORDINATE_EQUIPPED
All FRLs attached to this PCMG must be deleted and all the
timeslotS related to the PCMG must be free.
GET PCMG NAME=PCMG:0..31 [,REQATTL= PCML ,CRC ,CODE
,NUA ,BER ,BAF ,LOWBER ,REMAL];


A30808-X3247-M230-6-7619

833
CML:BSC PCMG
Id:0900d805800d4299
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PCMG
object class.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
System Responses:
- Operation Completed
GET PCMG BASICS
NAME: name
PCML: pcmLine
CRC: crc
CODE: code
NUA: NotUrgentAlarms
BER: BitErrorRate
BAF: baf
LOWBE
R:
lowerBitErrorRate
REMAL: remoteAlarmType
NAME: name
CRC: crc
BER: BitErrorRate


834 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
GET PCMG PCM24
GET PCMG PCM30
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET PCMG BASICS
None.
GET PCMG PCM24
None.
GET PCMG PCM30
None.
Example of Command Execution:
Get PCMG:NAME=PCMG:0,REQATTL=PCML&CRC&CODE&NUA&BER&BAF&
LOWBER&REMAL;
GET PCMG BASICS
Get PCMG BASICS:NAME=PCMG:0;
LOWBE
R:
lowerBitErrorRate
NAME: name
REMAL: remoteAlarmType
NAME: name
CODE: code
NUA: NotUrgentAlarms
BAF: baf
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

835
CML:BSC PCMG
Id:0900d805800d4299
GET PCMG PCM24
Get PCMG PCM24:NAME=PCMG:0;
GET PCMG PCM30
Get PCMG PCM30:NAME=PCMG:0;
GET PCMG BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PCMG
object class.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
BER ber
LOWBER lowerBitErrorRate
System Responses:
See GET PCMG
Application Guidelines:
See GET PCMG
Example of Command Execution:
See GET PCMG
GET PCMG PCM24
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG PCM24
GET PCMG BASICS NAME=PCMG:0..31;
GET PCMG PCM24 NAME=PCMG:0..31;


836 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PCMG
object class.
Long Names:
NAME Addres of the managed object
REMAL remoteAlarmType
System Responses:
See GET PCMG
Application Guidelines:
See GET PCMG
Example of Command Execution:
See GET PCMG
GET PCMG PCM30
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG PCM30
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PCMG
object class.
Long Names:
NAME Addres of the managed object
CODE code
NUA nua
BAF baf
System Responses:
See GET PCMG
Application Guidelines:
See GET PCMG
GET PCMG PCM30 NAME=PCMG:0..31;


A30808-X3247-M230-6-7619

837
CML:BSC PCMG
Id:0900d805800d4299
Example of Command Execution:
See GET PCMG
GET PCMG STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GET PCMG STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PCMG object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get PCMG STAT:NAME=PCMG:0;
GET PCMG STAT NAME=PCMG:0..31;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


838 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
GETINFO PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GETINFO PCMG
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the PCMG: AST, OST, AVS, CTS.
2. The working mode of the PCMG.
3. The LICD and LICD circuit which the PCMG line is connected to.
4. The identity of the FRL timeslot on PCMG line.
5. For both trunks: if equipped, the number of rising edges and the possible presence
for each type of alarms. All the alarms information (except the remote alarm
indication) contained in this GETINFO is relevant to the signal received by the BSC.
Each counter is increased by one each time the BSC detects the rising of that alarm.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT PCMG: <BSS ID> <PCMG NR> 11:41:14 22/03/1999
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
WORKING MODE: DOUBLE_TRUNK
LICD CONNECTED: 0 - 0
FRL TIMESLOT MAP: 1 7 9
TRUNK A EQUIPPED: TRUE
PCM-TRUNK-A ALARMS NR.OF RISING EDGES ALARM PRESENT
AIS 0 FALSE
CEERAL 0 FALSE
GETINFO PCMG NAME=PCMG:0..31;


A30808-X3247-M230-6-7619

839
CML:BSC PCMG
Id:0900d805800d4299
RAI 1 TRUE
EER 0 FALSE
LFA 1 FALSE
LOS 1 TRUE
LCAAL 0 FALSE
RNUA 0 FALSE
LNUA 0 FALSE
B5 0 FALSE
TXAL 0 TRUE
LBER 0 FALSE
SLIP 0 FALSE
L1CTS 1 FALSE
TRUNK B EQUIPPED: TRUE
PCM-TRUNK-B ALARMS NR.OF RISING EDGES ALARM PRESENT
AIS 0 FALSE
CEERAL 0 FALSE
RAI 1 TRUE
EER 0 FALSE
LFA 1 FALSE
LOS 1 FALSE
LCAAL 0 FALSE
RNUA 0 FALSE
LNUA 0 FALSE
B5 0 FALSE
TXAL 0 TRUE
LBER 0 FALSE
SLIP 0 FALSE
L1CTS 0 FALSE
16 KBIT/S TIMESLOTS:
1 2 3 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 23 24 25 26 27 28 29 30 31
64 KBIT/S TIMESLOTS:
4 22


840 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
END OF REPORT
- Operation Failed
GETINFO PCMG NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PCMG:
name = PCMG:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
1. The standard alarms, specified in the GSM recommendations, are the following:
AIS: Alarm Indication Signal
CEERAL: CRC Excessive Error Rate (only QTLP V1)
RAI: Remote Alarm Indication
EER: Excessive Error Rate
LFA: Loss of Frame Alignment
LOS: Loss of Signal
LCAAL: Loss of CRC Alignment (only QTLP V1)
LBER: Low BER threshold exceeded (only QTLP V2 and STLP)
SLIP: Slip alarm (some PCM frames are lost - only QTLP V2 and STLP)
As it can be seen, not all the types of LICD (QTLP V1 and QTLP V2) handle some
of these alarms.
2. The following alarm can be considered proprietary of BSC, and is present only for
QTLP V1):
TXAL (Transmission Alarm - only QTLP V1)
The TX alarm is an internal alarm, and reveals a parity alarm on the bit stream that
is sent by the switching matrix to the LICD.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

841
CML:BSC PCMG
Id:0900d805800d4299
3. The alarm counters are notified to MPCC by the firmware of the LICD, and they are
zeroed when a BSC initialization occurs (full or bring up), when the PCM line is
created and when there is a switch of the LICD (from LICD to LICDS or vice versa).
The only exceptions is the counter of the SLIP, which is managed by the software of
MPCC, and is independent from the LICD which the PCMS is working on. So this
counter is not reset after a switch of LICD.
4. The SLIP alarm, unlikely than the other alarms, is a spot event rather than an alarm
state. A "slip" in fact means the loss of one or more layer 1 frames due to the missing
synchronization between the two network elements.
The "presence" of the SLIP alarm is declared by the MPCC software when 3 frames
are lost in an hour, and the alarm disappears when no frames are lost in 20 minutes.
For the SLIP alarm the counter has the meaning of "number of lost frames since the
last BSC initialization or since the creation of the PCM line".
5. For the QTLP V2 with a FW version older than SBS-QF-3-1-06-00, in order to be
sure that the counters of the alarms different from SLIP are reset after a switch of
LICD, it is necessary to send, before the switch, a "perform test" command for the
LICD or LICDS that is going in service. This is because the older FW versions reset
the counters only when the LICD board is reset.
6. The information about the 16 kbit/s - 64kbit/s TIMESLOTS is related to the physical
usage of the timeslots in a certain moment.
This information could be different from the timeslot configuration in the database
when the peripheral hardware (PPXU) supporting the FRL link related to the
involved timeslots is disabled. In this case some timeslots configured as 64 kbit/s in
the database are shown as 16 kbit/s timeslots.
The example reported in "System Responses:" is due to the following condition:
the TIMESLOTS 1..12 have been assigned to FRL: 1 and it results UNLOCKED
ENABLED: for this reason the command GETINFO PCMG shows the TIMESLOTS
1..12 as 64 KBIT/S.
The TIMESLOTS 13..24 have been assigned to FRL: 0 and it results
UNLOCKED/DISABLED/DEPENDENCY because the superordinate PPXU is in
DISABLED state, for this reason the command GETINFO PCMG shows the
TIMESLOTS 13..24 as 16 KBIT/S.
When the FRL: 0 will become UNLOCKED ENABLED, the command GETINFO
PCMG will show also the TIMESLOTS 13..24 as 64 KBIT/S.
Example of Command Execution:
Getinfo PCMG:NAME=PCMG:0;
GETRELATIONSHIP PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GETRELATIONSHIP PCMG
GETRELATIONSHIP
PCMG
NAME=PCMG:0..31;


842 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the PCMG object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT and NTW.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PCMG:NAME=PCMG:0;
GETSUBO PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG GETSUBO PCMG
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO PCMG NAME=PCMG:0..31;


A30808-X3247-M230-6-7619

843
CML:BSC PCMG
Id:0900d805800d4299
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PCMG:NAME=PCMG:0;
LOCK PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG LOCK PCMG
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". All the
subordinated units shall be put in Disabled Dependency status. The PCU software shall
be informed about unavailability of involved FRL because it has to inform the remote end
about new link configuration. The command can cuase services interruption.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK PCMG NAME=PCMG:0..31;


844 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PCMG:NAME=PCMG:0;
SET PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG SET PCMG
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the PCMG object class.
Long Names:
NAME Addres of the managed object
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
System Responses:
- Operation Completed
Successful
INVALID_STATUS
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
SET PCMG NAME=PCMG:0..31 [,CRC=] [,CODE=] [,NUA=] [,BER=]
[,BAF=] [,LOWBER=] [,REMAL=];


A30808-X3247-M230-6-7619

845
CML:BSC PCMG
Id:0900d805800d4299
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
For PCM30:
Set PCMG:NAME=PCMG:0,CRC=FALSE,CODE=HDB3,NUA=FALSE,BER=0,
BAF=0;
For PCM24:
Set PCMG:NAME=PCMG:3,CRC=FALSE,CODE=HDB3,NUA=FALSE,BER=0,
BAF=0,LOWBER=0,REMAL=CCITT;
UNLOCK PCMG
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMG UNLOCK PCMG
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command removes the operator block and the unit remains in the operational state
as it is at the moment of the command. The PCU software shall be informed about avail-
ability of involved FRL because it has to inform the remote end about new link configu-
ration.
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
When the attributes CODE, BAF and CRC are changed the
PCMG must be in LOCKED state.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The attribute REMAL can be set only with the PCM24 lines
(parameter PCMTYPE of BSC object).
The attributes CODE, NUA and BAF can be set only with the
PCM30 lines (parameter PCMTYPE of BSC object).
The value assigned to LOWBER attribute must be greater or
equal to the BER one.
UNLOCK PCMG NAME=PCMG:0..31;


846 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4299
PCMG
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_INVALID_STATUS
Application Guidelines:
None.
Example of Command Execution:
Unlock PCMG:NAME=PCMG:0;


A30808-X3247-M230-6-7619

847
CML:BSC PCMS
Id:0900d805800d429c
PCMS
PCMS locates one of the PCM lines from/to TRAU (Asub interface).
CREATE PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS CREATE PCMS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a 2 Mbit PCM line on the Asub interface (PCMS) specifying its
parameters. It associates a PCMS with a given PCML identified by the LICD number and
the circuit number.
The parameter values must be equal to those in the TRAU data base.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LREDUNEQ lineRedundancyEquipped
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
WMOD workingMode
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE PCMS NAME=PCMS:0..47 ,PCML= [,CRC=] [,CODE=] [,NUA=]
[,BER=] [,BAF=] ,LREDUNEQ= [,LOWBER=] [,REMAL=]
[,WMOD=];
OBJECT_ALREADY_EQUIPPED


848 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
Application Guidelines:
1. After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
2. PCML + LREDUNEQ specify the plug for the PCM line.
3. The attribute REMAL can be set only with the PCM24 lines (parameter PCMTYPE
of BSC object).
4. The value assigned to LOWBER attribute must be greather or equal to the BER one.
This means that the bit error rate for LOWBER is lower or equal than the BER one.
For example: BER=E10-3, LOWBER=E10-5.
5. The attributes CODE, NUA and BAF can be set only with the PCM30 lines
(parameter PCMTYPE of BSC object).
6. For PCMB24 lines, the LOWBER threshold can be configured not depending on the
type of line interface cards that are being used. However,the alarm of the exceeded
LOWBER can be detected only by the QTLP V2 (on the BSC side, for PCMS), by
the BSCI V4 (on the TRAU side, for the PCMS). Nevertheless, if these cards are not
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The LICD object instance must be already equipped.
UNSUCCESSFUL_WRONG_LICD_CARD
If the network card is different from SNAP_STLP the
circuit of the PCML cannot be greater than 3.
UNSUCCESSFUL_EXCEED_OBJECT_NBR
The maximum number of configurable PCM lines (PCMB
+ PCMG + PCMS) is 72 with old MPCC or old BSC rack
type.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to Application Guidelines n. 3, n. 4, n. 5,
n. 7.
UNSUCCESSFUL_LINK_CONNECTED
The trunk of the LICD card corresponding to the refer-
enced line cannot be already connected to a PCM line. If
the PCMS line works in Double Trunk Mode both trunk
must be free (i.e no PCM line connected to that LICD cir-
cuit), while if the PCMS line works in Single Trunk Mode,
the relative trunk of LICD circuit must be free (i.e no
PCMS in Single Trunk mode with the same LREDUNEQ
and no other PCM in Double Trunk Mode).
In order to connect two PCMS lines to a same LICD
circuit, both PCMS must be in Single Trunk Mode and
LREDUNEQ attribute must be SIMPLEXA for one PCMS
and SIMPLEXB for the other.


A30808-X3247-M230-6-7619

849
CML:BSC PCMS
Id:0900d805800d429c
of the corrent edition, there will not be any misbehaviour, except for the fact that, on
the network element where the line interface card is not able to handle this alarm,
the related error messages will never be send to LMT and OMC.
7. The WMOD attribute can be set at SINGLE_TRUNK only if the PCMS attribute
LREDUNEQ is not set at DUPLEX.
Example of Command Execution:
For PCM30:
Create PCMB:NAME=PCMB:0,PCML=0-0,CRC=FALSE,CODE=HDB3,
NUA=FALSE, BER=E10_3,BAF=0,LREDUNEQ=DUPLEX,LOWBER=E10_3
For PCM24:
Create PCMS:NAME=PCMB:3,PCML=1-2,CRC=FALSE,BER=E10_3,
LREDUNEQ=SIMPLEXA, LOWBER=E10_3,REMAL=CCITT;
Create PCMS:NAME=PCMS:0,PCML=0-0,LREDUNEQ=SIMPLEXA,
WMOD=SINGLE_TRUNK;
Create PCMS:NAME=PCMS:1,PCML=0-0, LREDUNEQ=SIMPLEXB,
WMOD=SINGLE_TRUNK;
DELETE PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS DELETE PCMS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a 2 Mbit PCM line on the "A-sub" interface (PCMS) previously
created through the CREATE PCMS command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
DELETE PCMS NAME=PCMS:0..47;
OBJECT_NOTEQUIPPED
The object instance must be already equipped.


850 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
Application Guidelines:
None.
Example of Command Execution:
Delete PCMS:NAME=PCMS:0;
GET PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2Mbit PCM line on the "A-sub"
interface (PCMS) previously created through a CREATE PCMS command.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LREDUNEQ lineRedundancyEquipped
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
WMOD workingMode
SUBORDINATE_EQUIPPED
No signalling link (LAPD, SS7, O&M) has to be implemented
in the PCM line.
All the NUC object instances associated to the PCMS object
instance must be previously deleted.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a PCMS, the relative object instance must be
in LOCKED state.
GET PCMS NAME=PCMS:0..47 [,REQATTL= PCML ,CRC ,CODE ,NUA
,BER ,BAF ,LREDUNEQ ,LOWBER ,REMAL ,WMOD
,TOPOREL];


A30808-X3247-M230-6-7619

851
CML:BSC PCMS
Id:0900d805800d429c
TOPOREL topologicalRelationship
System Responses:
- Operation Completed
GET PCMS BASICS
GET PCMS PCM24
GET PCMS PCM30
NAME: name
PCML: pcmLine
CRC: crc
CODE: code for PCM24 line No-Config is displayed
NUA: nua for PCM24 line No-Config is displayed
BER: ber
BAF: baf for PCM24 line No-Config is displayed
LREDUNEQ: lineRedundancyEquipped
LOWBER: lowerBitErrorRate
REMAL: remoteAlarmType for PCM24 only
WMOD: workingMode
TOPOREL: topologicalRelationship
NAME: name
CRC: crc
BER: ber
LREDUNEQ: lineRedundancyEquipped
LOWBER: lowerBitErrorRate
WMOD: workingMode
TOPOREL: topologicalRelationship
NAME: name
REMAL: remoteAlarmType for PCM24 only
NAME: name
CODE: code
NUA: nua


852 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET PCMS BASICS
None.
GET PCMS PCM24
None.
GET PCMS PCM30
None.
Example of Command Execution:
Get PCMS:NAME=PCMS:0,REQATTL=PCML&CRC&CODE&NUA&BER&BAF& LRE-
DUNEQ&LOWBER&REMAL&WMOD&TOPOREL;
GET PCMS BASICS
Get PCMS BASICS:NAME=PCMS:0;
GET PCMS PCM24
Get PCMS PCM24:NAME=PCMS:0;
GET PCMS PCM30
Get PCMS PCM30:NAME=PCMS:0;
GET PCMS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS BASICS
Applicability:
Phase 2.
BAF: baf
NOT_EQUIPPED
The object instance must be already equipped.
GET PCMS BASICS NAME=PCMS:0..47;


A30808-X3247-M230-6-7619

853
CML:BSC PCMS
Id:0900d805800d429c
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2Mbit PCM line on the "A-sub"
interface (PCMS) previously created through a CREATE PCMS command.
Long Names:
NAME Addres of the managed object
PCML pcmLine
CRC crc
BER ber
LREDUNEQ lineRedundancyEquipped
LOWBER lowerBitErrorRate
WMOD workingMode
TOPOREL topologicalRelationship
System Responses:
See GET PCMS
Application Guidelines:
See GET PCMS
Example of Command Execution:
See GET PCMS
GET PCMS PCM24
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS PCM24
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2Mbit PCM line on the "A-sub"
interface (PCMS) previously created through a CREATE PCMS command.
Long Names:
NAME Addres of the managed object
REMAL remoteAlarmType
System Responses:
See GET PCMS
GET PCMS PCM24 NAME=PCMS:0..47;


854 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
Application Guidelines:
See GET PCMS
Example of Command Execution:
See GET PCMS
GET PCMS PCM30
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS PCM30
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a 2Mbit PCM line on the "A-sub"
interface (PCMS) previously created through a CREATE PCMS command.
Long Names:
NAME Addres of the managed object
CODE code
NUA nua
BAF baf
System Responses:
See GET PCMS
Application Guidelines:
See GET PCMS
Example of Command Execution:
See GET PCMS
GET PCMS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GET PCMS STAT
Applicability:
Phase 2.
Visibility level: 0.
GET PCMS PCM30 NAME=PCMS:0..47;
GET PCMS STAT NAME=PCMS:0..47;


A30808-X3247-M230-6-7619

855
CML:BSC PCMS
Id:0900d805800d429c
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PCMS object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get PCMS STAT:NAME=PCMS:1;
GETINFO PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETINFO PCMS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the PCMS: AST, OST, AVS, CTS.
2. The working mode of the PCMS.
3. The LICD which the PCMS line is connected to and the circuit.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object selected must be created.
GETINFO PCMS NAME=PCMS:0..47;


856 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
4. The identity of the SS7 signalling timeslots and the LAPD timeslot on the PCMS line.
5. The identity of the X25A signalling timeslots on the PCMS line.
6. The identity of the NUC timeslot on the PCMS line.
7. The identity of the FRL timeslot on the PCMS line.
8. The number of traffic channels.
9. The number of idle and busy channels.
10. The TRAU and PCMT connected with this PCMS line.
11. For both trunks: if equipped, the number of rising edges and the possible presence
for each type of alarms. All the alarms information (except the remote alarm
indication) contained in this GETINFO is relevant to the signal received by the BSC.
Each counter is increased by one each time the BSC detects the rising of that alarm.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT PCMS: <BSS ID> <PCMS NR> 11:41:14 22/03/1999
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
WORKING MODE: DOUBLE TRUNK
LICD CONNECTED: 0 - 0 (LICD NR - CIRC NR)
SS7L TIMESLOT: 16 29
X25A TIMESLOT: NONE
LPDL TIMESLOT: 3
NUC TIMESLOT: NONE
FRL TIMESLOT: 1
TRAFFIC CH (TOTAL): 27
TRAFFIC CH BUSY: 0
TRAFFIC CH IDLE: 27
TRUNK A EQUIPPED TRUE
PCM-TRUNK-A ALARMS NR.OF RISING EDGES ALARM PRESENT
AIS 0 FALSE
CEERAL 0 FALSE
RAI 1 TRUE


A30808-X3247-M230-6-7619

857
CML:BSC PCMS
Id:0900d805800d429c
EER 0 FALSE
LFA 1 FALSE
LOS 1 TRUE
LCAAL 0 FALSE
RNUA 0 FALSE
LNUA 0 FALSE
B5 0 FALSE
TXAL 0 FALSE
LBER 0 FALSE
SLIP 0 FALSE
L1CTS 1 FALSE
TRUNK B EQUIPPED TRUE
PCM-TRUNK-B ALARMS NR.OF RISING EDGES ALARM PRESENT
AIS 0 FALSE
CEERAL 0 FALSE
RAI 1 TRUE
EER 0 FALSE
LFA 1 FALSE
LOS 1 FALSE
LCAAL 0 FALSE
RNUA 0 FALSE
LNUA 0 FALSE
B5 0 FALSE
TXAL 0 FALSE
LBER 0 FALSE
SLIP 0 FALSE
L1CTS 0 FALSE
16 KBIT/S TIMESLOTS:
2 3 5 6 7 8 9 10 11 12 13 14 15 17
19 20 21 23 24 25 26 27 28 30 31
64 KBIT/S TIMESLOTS:
1 16 18 29
END OF REPORT
- Operation Failed


858 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
GETINFO PCMS NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PCMS:
name = PCMS:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
1. The standard alarms, specified in the GSM recommendations, are the following:
AIS: Alarm Indication Signal
CEERAL: CRC Excessive Error Rate (only QTLP V1)
RAI: Remote Alarm Indication
EER: Excessive Error Rate
LFA: Loss of Frame Alignment
LOS: Loss Of Signal
LCAAL: Loss of CRC Alignment (only QTLP V1)
LBER: Low BER threshold exceeded (only QTLP V2 and STLP)
SLIP: Slip alarm (some PCM frames are lost - only QTLP V2 and STLP)
As it can be seen, not all the types of LICD (QTLP V1 and V2) handle some of these
alarms
2. The following alarm can be considered proprietary of BSC, and is present only for
QTLP V1):
TXAL (Transmission Alarm - only QTLP V1)
The TX alarm is an internal alarm, and reveals a parity alarm on the bit stream that
is sent by the switching matrix to the LICD.
3. The alarm counters are notified to MPCC by the firmware of the LICD, and they are
zeroed when there is a BSC initialization (full or bring up), when the PCM line is
created and when there is a switch of the LICD (from LICD to LICDS or vice versa).
The only exception is the counter of the SLIP, which is managed by the software of
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

859
CML:BSC PCMS
Id:0900d805800d429c
MPCC, and is independent from the LICD which the PCMS is working on. So these
two counters are not reset after a switch of LICD.
4. The SLIP alarm, unlikely than the other alarms, is a spot event rather than an alarm
state. A "slip" in fact means the loss of one or more layer 1 frames due to the missing
synchronization between the two network elements.
The "presence" of the SLIP alarm is declared by the MPCC software when 3 frames
are lost in an hour, and the alarm disappears when no frames are lost in 20 minutes.
For the SLIP alarm the counter has the meaning of "number of lost frames since the
last BSC initialization or since the creation of the PCM line".
5. For the QTLP V2 with a FW version older than SBS-QF-3-1-06-00, in order to be
sure that the counters of the alarms different from SLIP are reset after a switch of
LICD, it is necessary to send, before the switch, a "perform test" command for the
LICD or LICDS that is going in service.
This is because the older FW versions reset the counters only when the LICD board
is reset.
Example of Command Execution:
Getinfo PCMS:NAME=PCMS:0;
GETREDSTAT PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETREDSTAT PCMS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve information about the PCMS lines configured in duplex
mode. It shows which is the active link.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETREDSTAT PCMS NAME=PCMS:0..47;
Successful
LKAPCM This attribute identifies which PCM link is active.
Validity range:
linkActivePcm linkA
linkB
LKSPCM This attribute represents the State of the link


860 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
GetREDSTAT PCMS:NAME=PCMS:1;
GETRELATIONSHIP PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETRELATIONSHIP PCMS
Validity range:
linkStatePcm linkAandBOk
linkAnotOk
linkBnotOk
bothNotOk
LKCONFPCM This attribute represents the current bit selection.
It is meaningful only for PCMS linesBinary values repre-
senting the source of data in the PCM line. If the i-th bit is
0 then the i-th channel is receiving data from link A; other-
wise from link B. Data will be shown as follows: 7-0
0011001015-8 ..... 127-120 ....
INVALID_COMMAND
The syntax of the message received from LMT is incor-
rect.
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
PCML_DISABLED_DEPENDENCY
The line is disabled because LICD is unavailable so it can
not be monitored.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The line is configured as simplex.
GETRELATIONSHIP
PCMS
NAME=PCMS:0..47;


A30808-X3247-M230-6-7619

861
CML:BSC PCMS
Id:0900d805800d429c
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the PCMS object the related HMOs are the following: LICD/LICDS, EPWR, BSMS,
TPWR, PWRD, MPCC, TDPC, MEMT and NTW.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PCMS:NAME=PCMS:0;
GETSUBO PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS GETSUBO PCMS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO PCMS NAME=PCMS:0..47;


862 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PCMS:NAME=PCMS:0;
LOCK PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS LOCK PCMS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK PCMS NAME=PCMS:0..47;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.


A30808-X3247-M230-6-7619

863
CML:BSC PCMS
Id:0900d805800d429c
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PCMS:NAME=PCMS:0;
SET PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS SET PCMS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the redundancy equipment of a PCM line on A sub interface.
The parameter values must be equal to those in the TRAU data base.
Long Names:
NAME Addres of the managed object
CRC crc
CODE code
NUA nua
BER ber
BAF baf
LREDUNEQ lineRedundancyEquipped
LOWBER lowerBitErrorRate
REMAL remoteAlarmType
System Responses:
- Operation Completed
Successful
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET PCMS NAME=PCMS:0..47 [,CRC=] [,CODE=] [,NUA=] [,BER=]
[,BAF=] [,LREDUNEQ=] [,LOWBER=] [,REMAL=];


864 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429c
PCMS
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
For PCM30:
Set PCMS:NAME=PCMS:0,CRC=FALSE,BAF=6,LREDUNEQ=DUPLEX,
REMAL=CCITT,CODE=HDB3,NUA=FALSE,BER=E10_3,LOWBER=E10_3;
For PCM24:
Set PCMS:NAME=PCMS0:CRC=FALSE,LREDUNEQ=DUPLEX,BER=E10_3, LOW-
BER=E10_3;
UNLOCK PCMS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMS UNLOCK PCMS
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
INVALID_COMMAND
The LREDUNEQ attribute can be changed only from SIMPLEXA
or SIMPLEXB to DUPLEX. No other changes are allowed.
UNSUCCESSFUL_INVALID_STATUS
When the attributes BAF and CRC4 are changed the PCMS must
be in LOCKED state.
Setting of CODE attribute is allowed only if the PCMS is in
LOCKED status.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The BAF attribute can be set only with the PCM30 lines (param-
eter PCMTYPE of BSC object).
The REMAL attribute can be set only with the PCM24 lines
(PCMTYPE attribute of BSC object).
The CODE and NUA attributes can be set only with the PCM30
lines (parameter PCMTYPE of BSC object).
The value assigned to LOWBER attribute must be greater than or
equal to the BER one. This means that the bit error rate for
LOWBER is lower or equal than the BER one. For example
LOWBER=3 (10-6 bit error rate), BER=2 (10-5 bit error rate).
The LREDUNEQ attribute can be set at DUPLEX only if the
WMOD attribute is set at DOUBLE_TRUNK.
UNLOCK PCMS NAME=PCMS:0..47;


A30808-X3247-M230-6-7619

865
CML:BSC PCMS
Id:0900d805800d429c
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock PCMS:NAME=PCMS:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


866 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
PCU
The PCU functional object represents the packet control unit designed to implement
GPRS service in SBS; depending on the BSC type PCU can be implemented by means
of PPXU boards (in case of High Capacity BSC).
In case of PPXU boards each PCU can handle 256 PDTs on A-bis interface with a
maximum of 64 FRLs on Gb interface.
CREATE PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU CREATE PCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the PCU object class. The creation of the PCU
object implies the consequent creation of:
one PPXU (with the same instance number of PCU) if the NTWCARD is either
NTWSNAP or NTWSNAP_STLP.
If NTWCARD = NTWSNAP or NTWSNAP_STLP, the system firstly creates one PPXU
object, starting in "Unlocked-Disabled/Not Initialized" state, and then the PCU object,
that is "Locked-Disabled/Dependency/Not Initialized". When the card will be "Providing
Service", then the PCU will start the configuration alignment.
When NTWCARD = NTWSNAP or NTWSNAP_STLP, the PPLD cannot be equipped,
therefore each PCU can be created with the only precondition that one EPWR is
created.
To create one PCU (PCU 0):
create PCU 0.
This operation automatically creates the object PPXU 0.
CREATE PCU NAME=PCU:0..11 [,NMO=] ,NSEI= [,TNSVCBLK=] [,NNS-
VCBLKR=] [,NNSVCUBLR=] [,TNSVCR=] [,NNSVCRR=]
[,TNSVCTST=] [,TNSVCPTST=] [,NNSVCTSTR=]
[,THPROXT=] [,PFCFCSUP=] [,PFCSUP=] [,BEPFITODIFF-
SERV=] [,SPFITODIFFSERV=] [,SMSPFITODIFFSERV=]
[,STREAMTODIFFSERV=] [,BCGRTODIFFSERV=]
[,INTRTRFH1TODIFFSERV=]
[,INTRTRFH2TODIFFSERV=]
[,INTRTRFH3TODIFFSERV=] ,CPCUN= [,STREAMSUP=]
[,GBSNS=] [,TYPOFNSVCCONF=] [,TSNPRO=] [,SNSSIZ-
ERET=] [,SNSCONFRET=] [,SNSADDRET=] [,SNSDEL-
RET=] [,SNSCHWEIRET=] [,PORT<n>=] [,MTU=]
[,DIFFSERVSUP=] [,STPIPEP=];


A30808-X3247-M230-6-7619

867
CML:BSC PCU
Id:0900d805800d429f
Long Names:
NAME Addres of the managed object
NMO networkModeOfOperation
NSEI networkServiceElementIdentifier
TNSVCBLK timerInNsvcBlockProcedure
NNSVCBLKR numberOfNsvcBlockRetries
NNSVCUBLR numberOfNsvcUnblockRetries
TNSVCR timerInNsvcResetProcedure
NNSVCRR numberOfNsvcResetRetries
TNSVCTST timerInNsvcTestProcedure
TNSVCPTST timerInNsvcPeriodicTestProcedure
NNSVCTSTR numberOfNsvcTestRetries
THPROXT thresholdProximityTimer
PFCFCSUP packetFlowContextFlowControlSupport
PFCSUP pfcSupport
BEPFITODIFFSERV bestEffortPFIToDiffserv
SPFITODIFFSERV signallingPFIToDiffserv
SMSPFITODIFFSERV smsPFIToDiffserv
STREAMTODIFFSERV streamingToDiffserv
BCGRTODIFFSERV backgroundToDiffserv
INTRTRFH1TODIFFSERV interactiveTrafficHandlingPrio1ToDiffserv
INTRTRFH2TODIFFSERV interactiveTrafficHandlingPrio2ToDiffserv
INTRTRFH3TODIFFSERV interactiveTrafficHandlingPrio3ToDiffserv
CPCUN commonPCUNumber
STREAMSUP streamingSupport
GBSNS gBSubNetworkService
TYPOFNSVCCONF typeOfNSVCConfiguration
TSNPRO timeSubnetworksProcedure
SNSSIZERET subnetworksSizeRetries
SNSCONFRET subnetworksConfigRetries
SNSADDRET subnetworksAddRetries
SNSDELRET subnetworksDeleteRetries
SNSCHWEIRET sNSChangeWeigthRetries
PORT<n> port<n>
MTU mtu
DIFFSERVSUP differentServiceSupport
STPIPEP startupRemoteIPEndpoint
System Responses:
- Operation Completed


868 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
Successful
- Operation Failed
NACK CAUSES:
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The superordinate EPWR must be already created if the NTWCARD is
different from NTWSNAP_STLP.
The related CPCU doesn't exist.
The GBSNS attribute cannot be set to IPV4 if the couple of superordi-
nate GBIPLNK are not already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
In order to set PFCSUP value to DISABLED, the PFCFCSUP value
must be DISABLED.
In order to set PFCSUP value to ENABLED, the SISGSNREL99 value
must be ENABLED.
The attribute PFCFCSUP can be set to TRUE only if PFCSUP is
enabled.
If the GBSNS attribute is set to a value different from IPV4 the following
attributes must be set to <NULL>: TYPOFNSVCCONF, TSNSPRO,
SNSSIZERET, SNSCONFRET, SNSADDRET, SNSDELRET, SNSCH-
WEIRET, PORT0, PORT1, MTU, DIFFSERVSUP.
If the GBSNS attribute is set to IPV4 the following attributes must be set
to a value different from <NULL>: TYPOFNSVCCONF, TSNSPRO,
SNSSIZERET, SNSCONFRET, SNSADDRET, SNSDELRET, SNSCH-
WEIRET, PORT0, PORT1, MTU, DIFFSERVSUP.
The value of PORT0, PORT1 and the field IPAddress of STPIPEP must
be valid IP address.
The PORT0 and PORT1 cannot be set with the same IP address.
The STPIPEP attribute must be set to NULL if the TYPOFNSVCCONF
attribute is set to a value different from DYNAMIC. The STPIPEP
attribute must be set to a value different from NULL if the TYPOFNSVC-
CONF attribute is set to DYNAMIC.
If the GBSNS attribute is set to IPV4 the following attributes must be set
to <NULL>: NNSVCBLKR, NNSVCUBLR, NNSVCRR, TNSVCBLK,
TNSVCR.
If the GBSNS attribute is set to a value different from IPV4 the following
attributes must be set to a value different from <NULL>: NNSVCBLKR,
NNSVCUBLR, NNSVCRR, TNSVCBLK, TNSVCR.
UNSUCCESSFUL_EXCEED_OBJECT_NBR


A30808-X3247-M230-6-7619

869
CML:BSC PCU
Id:0900d805800d429f
Application Guidelines:
1. In case of trouble on redundant NSVC links created on the Gb interface, it could
happen that PTPPKF object is disabled while NSVC is still enabled. In order to avoid
this situation the following rule has to be followed:
TF1*"number of flow control retries" > TNSVCTST + TNSVCPTST*NNSVCTSTR.
The "number fo flow control retries" is not manageable by operator and is fixed to 15.
Default values of all the above attributes are in according with the rule.
2. The NMO value must be the same for all PCUs; it is a task of the operator to guar-
antee this condition.
Example of Command Execution:
Create PCU:NAME=PCU:0,NMO=2,NSEI=40,TNSVCBLK=3,NNSVCBLKR=25,
NNSVCUBLR=7,TNSVCR=6,NNSVCRR=32,TNSVCTST=20,TNSVCPTST=5,
NNSVCTSTR=20,THPROXT=30-90-120,PFCFCSUP=FALSE,GBSNS=FRFIX,
TYPOFNSVCCONF=NULL, TSNPRO=NULL, SNSSIZERET=NULL, SNSCON-
FRET=NULL, SNSADDRET=NULL, SNSDELRET=NULL, SNSCHWEIRET=NULL,
PORT0=NULL, PORT1=NULL, MTU=NULL, DIFFSERVSUP=NULL, STPIPEP=NULL,
CPCUN=0;
DELETE PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU DELETE PCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the PCU object class. The
PPXU cards related to this PCU functionality will be implicitly deleted by the system.
Long Names:
NAME Addres of the managed object
The maximum number of PCUs per BSS is 12 if the network card is
NTWSNAP_STLP with new MPCC board.
UNSUCCESSFUL_VAR_OUT_RANGE
The max number of PCUs has been reached; no other PCUs can be
equipped.
UNSUCCESSFUL_INVALID_STATUS
In order to modify PFCSUP attribute, the PCU must be locked.
DELETE PCU NAME=PCU:0..11;


870 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete PCU:NAME=PCU:0;
GET PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU GET PCU
Applicability:
Phase 2.
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
All the FRL object instances associated to the PCU object instance
must be previously deleted.
If the PCU object instance is the last equipped in the BSC all
PTPPKF object instances must be deleted.
The last PCU related to a CPCU cannot be removed if a PTPPKF is
equipped under that CPCU.
All the NSVLIP object instances subordinated to the PCU object
instance must be previously deleted.
The last PCU over IP of a CPCU can be deleted only if there are no
PTPPKFs equipped or if a NSVC exists under that CPCU.
GET PCU NAME=PCU:0..11 [,REQATTL= NMO ,NSEI ,TNSVCBLK
,NNSVCBLKR ,NNSVCUBLR ,TNSVCR ,NNSVCRR ,TNS-
VCTST ,TNSVCPTST ,NNSVCTSTR ,THPROXT ,PFCFC-
SUP ,PFCSUP ,BEPFITODIFFSERV ,SPFITODIFFSERV
,SMSPFITODIFFSERV ,STREAMTODIFFSERV ,BCGRTO-
DIFFSERV ,INTRTRFH1TODIFFSERV
,INTRTRFH2TODIFFSERV ,INTRTRFH3TODIFFSERV
,CPCUN ,STREAMSUP ,GBSNS ,TYPOFNSVCCONF
,TSNPRO ,SNSSIZERET ,SNSCONFRET ,SNSADDRET
,SNSDELRET ,SNSCHWEIRET ,PORT<n> ,MTU ,DIFF-
SERVSUP ,STPIPEP];


A30808-X3247-M230-6-7619

871
CML:BSC PCU
Id:0900d805800d429f
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PCU object
class.
Long Names:
NAME Addres of the managed object
NMO networkModeOfOperation
NSEI networkServiceElementIdentifier
TNSVCBLK timerInNsvcBlockProcedure
NNSVCBLKR numberOfNsvcBlockRetries
NNSVCUBLR numberOfNsvcUnblockRetries
TNSVCR timerInNsvcResetProcedure
NNSVCRR numberOfNsvcResetRetries
TNSVCTST timerInNsvcTestProcedure
TNSVCPTST timerInNsvcPeriodicTestProcedure
NNSVCTSTR numberOfNsvcTestRetries
THPROXT thresholdProximityTimer
PFCFCSUP packetFlowContextFlowControlSupport
PFCSUP pfcSupport
BEPFITODIFFSERV bestEffortPFIToDiffserv
SPFITODIFFSERV signallingPFIToDiffserv
SMSPFITODIFFSERV smsPFIToDiffserv
STREAMTODIFFSERV streamingToDiffserv
BCGRTODIFFSERV backgroundToDiffserv
INTRTRFH1TODIFFSERV interactiveTrafficHandlingPrio1ToDiffserv
INTRTRFH2TODIFFSERV interactiveTrafficHandlingPrio2ToDiffserv
INTRTRFH3TODIFFSERV interactiveTrafficHandlingPrio3ToDiffserv
CPCUN commonPCUNumber
STREAMSUP streamingSupport
GBSNS gBSubNetworkService
TYPOFNSVCCONF typeOfNSVCConfiguration
TSNPRO timeSubnetworksProcedure
SNSSIZERET subnetworksSizeRetries
SNSCONFRET subnetworksConfigRetries
SNSADDRET subnetworksAddRetries
SNSDELRET subnetworksDeleteRetries
SNSCHWEIRET sNSChangeWeigthRetries
PORT<n> port<n>
MTU mtu


872 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
DIFFSERVSUP differentServiceSupport
STPIPEP startupRemoteIPEndpoint
System Responses:
- Operation Completed
NAME: name
NMO: networkModeOf Operation
NSEI: NetworkServiceElementIdentifier
TNSVCBLK: timerInNsvcBlockProcedure
NNSVCBLKR: numberOfNsvcBlockRetries
NNSVCUBLR: numberOfNsvcUnblockRetries
TNSVCR: timerNsvcReset
NNSVCRR: numberOfNsvcResetRetries
TNSVCTST: timerInNsvcTestProcedure
TNSVCPTST: timerNsvcPeriodicTestProcedure
NNSVCTSTR: NumberOfNsvcTestRetries
THPROXT: thresholdProximityTimer
PFCSUP pfcSupport
STREAMSUP streamingSupport
BEPFITODIFFSERV bestEffortPFIToDiffserv
SPFITODIFFSERV signallingPFIToDiffserv
SMSPFITODIFFSERV smsPFIToDiffserv
STREAMTODIFFSERV streamingToDiffserv
BCGRTODIFFSERV backgroundToDiffserv
INTRTRFH1TODIFFSER
V
interactiveTrafficHandlingPriority1ToDiffserv
INTRTRFH2TODIFFSER
V
interactiveTrafficHandlingPriority2ToDiffserv
INTRTRFH3TODIFFSER
V
interactiveTrafficHandlingPriority3ToDiffserv
PFCFCSUP: packetFlowContextFlowControlSupport
GBSNS: gBSubNetworkService
TYPOFNSVCCONF: typeOfNSVCConfiguration
TSNPRO: timeSubnetworksProcedure
SNSSIZERET: subnetworksSizeRetries
SNSCONFRET: subnetworksConfigRetries
SNSADDRET: subnetworksAddRetries
SNSDELRET: subnetworksDeleteRetries


A30808-X3247-M230-6-7619

873
CML:BSC PCU
Id:0900d805800d429f
GET PCU BASICS
SNSCHWEIRET: sNSChangeWeightRetries
PORT0: port0
PORT1: port1
MTU: mtu
DIFFSERVSUP: differentServiceSupport
STPIPEP: startupRemoteIPEndpoint
NAME: name
NMO: networkModeOf Operation
NSEI: NetworkServiceElementIdentifier
TNSVCBLK: timerInNsvcBlockProcedure
NNSVCBLKR: numberOfNsvcBlockRetries
NNSVCUBLR: numberOfNsvcUnblockRetries
TNSVCR: timerNsvcReset
NNSVCRR: numberOfNsvcResetRetries
TNSVCTST: timerInNsvcTestProcedure
TNSVCPTST: timerNsvcPeriodicTestProcedure
NNSVCTSTR: NumberOfNsvcTestRetries
THPROXT: thresholdProximityTimer
PFCSUP pfcSupport
STREAMSUP streamingSupport
BEPFITODIFFSERV bestEffortPFIToDiffserv
SPFITODIFFSERV signallingPFIToDiffserv
SMSPFITODIFFSERV smsPFIToDiffserv
STREAMTODIFFSERV streamingToDiffserv
BCGRTODIFFSERV backgroundToDiffserv
INTRTRFH1TODIFFSERV interactiveTrafficHandlingPriority1ToDiffserv
INTRTRFH2TODIFFSERV interactiveTrafficHandlingPriority2ToDiffserv
INTRTRFH3TODIFFSERV interactiveTrafficHandlingPriority3ToDiffserv
PFCFCSUP: packetFlowContextFlowControlSupport
GBSNS: gBSubNetworkService
TYPOFNSVCCONF: typeOfNSVCConfiguration
TSNPRO: timeSubnetworksProcedure
SNSSIZERET: subnetworksSizeRetries
SNSCONFRET: subnetworksConfigRetries


874 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET PCU BASICS
None.
Example of Command Execution:
Get PCU:NAME=PCU:0,REQATTL=NMO&NSEI&TNSVCBLK&NNSVCBLKR& NNS-
VCUBLR&TNSVCR&NNSVCRR&TNSVCTST&TNSVCPTST&NNSVCTSTR&
THPROXT&PFCSUP&STREAMSUP&BEPFITODIFFSERV&SPFITODIFF-
SERV&SMSPFITODIFFSERV&STREAMTODIFFSERV&BCGRTODIFF-
SERV&INTRTRFH1TODIFFSERV&INTRTRFH2TODIFFSERV&INTRTRFH3TODIFF
SERV&PFCFCSUP&GBSNS&TYPOFNSVCCONF&TSNPRO&SNSSIZERET&
SNSCONFRET&SNSADDRET&SNSDELRET&SNSCHWEIRET&PORT0& PORT1&
MTU&DIFFSERVSUP&STPIPEP;
GET PCU BASICS
Get PCU BASICS:NAME=PCU:0;
GET PCU BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU GET PCU BASICS
Applicability:
Phase 2.
SNSADDRET: subnetworksAddRetries
SNSDELRET: subnetworksDeleteRetries
SNSCHWEIRET: sNSChangeWeightRetries
PORT0: port0
PORT1: port1
MTU: mtu
DIFFSERVSUP: differentServiceSupport
STPIPEP: startupRemoteIPEndpoint
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET PCU BASICS NAME=PCU:0..11;


A30808-X3247-M230-6-7619

875
CML:BSC PCU
Id:0900d805800d429f
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PCU object
class.
Long Names:
NAME Addres of the managed object
NMO networkModeOfOperation
NSEI networkServiceElementIdentifier
TNSVCBLK timerInNsvcBlockProcedure
NNSVCBLKR numberOfNsvcBlockRetries
NNSVCUBLR numberOfNsvcUnblockRetries
TNSVCR timerInNsvcResetProcedure
NNSVCRR numberOfNsvcResetRetries
TNSVCTST timerInNsvcTestProcedure
TNSVCPTST timerInNsvcPeriodicTestProcedure
NNSVCTSTR numberOfNsvcTestRetries
THPROXT thresholdProximityTimer
PFCFCSUP packetFlowContextFlowControlSupport
PFCSUP pfcSupport
BEPFITODIFFSERV bestEffortPFIToDiffserv
SPFITODIFFSERV signallingPFIToDiffserv
SMSPFITODIFFSERV smsPFIToDiffserv
STREAMTODIFFSERV streamingToDiffserv
BCGRTODIFFSERV backgroundToDiffserv
INTRTRFH1TODIFFSERV interactiveTrafficHandlingPrio1ToDiffserv
INTRTRFH2TODIFFSERV interactiveTrafficHandlingPrio2ToDiffserv
INTRTRFH3TODIFFSERV interactiveTrafficHandlingPrio3ToDiffserv
CPCUN commonPCUNumber
STREAMSUP streamingSupport
GBSNS gBSubNetworkService
TYPOFNSVCCONF typeOfNSVCConfiguration
TSNPRO timeSubnetworksProcedure
SNSSIZERET subnetworksSizeRetries
SNSCONFRET subnetworksConfigRetries
SNSADDRET subnetworksAddRetries
SNSDELRET subnetworksDeleteRetries
SNSCHWEIRET sNSChangeWeigthRetries
PORT<n> port<n>
MTU mtu


876 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
DIFFSERVSUP differentServiceSupport
STPIPEP startupRemoteIPEndpoint
System Responses:
See GET PCU
Application Guidelines:
See GET PCU
Example of Command Execution:
See GET PCU
GET PCU STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU GET PCU STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command ais used to retrieve the following State/Status attributes related to the
PCU object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
GET PCU STAT NAME=PCU:0..11;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

877
CML:BSC PCU
Id:0900d805800d429f
Application Guidelines:
None.
Example of Command Execution:
Get PCU STAT:NAME=PCU:0;
GETINFO PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU GETINFO PCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the PCU: AST, OST, AVS, CTS, STNDBY, PRS.
2. The enhanced flow control support and status
3. The Network Service Element Identifier (NSEI) value.
4. The HW version, the GBSNS and, when GBSNS value is IPV4, the NSCV config.
5. For each PDT the following information:
the internal timeslot number;
the BVCI number;
the BTSM number;
the BTS number;
the TRX number;
the CHAN number;
the type;
the usage state;
the resync counter.
6. PCU IP address 0 and PCU IP address 1
7. If GBSNS value is FRFIX or FRVAR, the list of FRL; for each FRL the following infor-
mation:
GETINFO PCU NAME=PCU:0..11;


878 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
the FRL absolute number, the AST and OST;
the internal timeslot map;
the speed;
max 12 samples for the transmission load percentage;
max 12 samples for the receiving load percentage;
max 6 samples for the crc counter in the last 5 minutes;
max 6 samples for the invalid counter in the last 5 minutes;
max 6 samples for the invalid dlci counter in the last 5 minutes;
the DLCI list.
8. If GBSNS value is IPV4, the list of NSVLIP; for each NSVLIP the following informa-
tion:
AST, OST, AVS and CST;
The IP port (values: 0 or 1) and UPFD port (range:1024 .. 0xFFFF);
Weigth Data and Signalling;
For each NSVCIP equipped:
OST, AVS and CTS;
Remote IP Address and Remote UPD port
Weigth Data and Signalling
Number of NS PDU received (sampled at 5 min. intervals) with syntactical errors
Number of NS PDU received (sampled at 5 min. intervals) with semantic errors
Number of erroneous NS PDU received (sampled at 5 min. intervals)
Number of non erroneous NS PDU received (sampled at 5 min. intervals)
Number of NS PDU received (sampled at 5 min. intervals) causing other events
The list of max 400 PTPPKF connected
( I ) If the LMT is connected in remote mode, it is not possible to execute this command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO PCU ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT PCU:
NAME = PCU:0
Layout PCU with FR configuration


A30808-X3247-M230-6-7619

879
CML:BSC PCU
Id:0900d805800d429f
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: PROVIDING_SERVICE
PROCEDURAL STATUS: NONE
EFC SUPPORTED: TRUE
EFC STATUS: ENABLED
NSEI: 12

HW VERSION: PPXU_V2
GBSNS: FRFIX
PDT NR. INT.TSL NR. BVCI NR. BTSM NR. BTS NR. TRX NR.
0 0 0 0 0 0
...; ...; ...; ...; ...; ...; ...; ...; ...; ...; ...; ...;
399 1 1 1 1 0
PDT NR. CHAN NR. TYPE USAGE RESYNC COUNT.
0 2 PCCCH IDLE 0
...; ...; ...; ...; ...; ...; ...; ...; ...; ...;
399 6 PBCCH IDLE 0
FRL ABSOLUTE NR.: 7
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
INTERNAL TIMESLOT MAP: 66 67
SPEED: 192 KB/S
TX LOAD %: 5 3 10 40 50 55 60 65 70
80 90 100
RX LOAD %: 30
CRC LAST 5 MIN: 5 3 10 2 1 3
INVALID LAST 5 MIN: 7
INVALID DLCI LAST 5 MIN: 11


880 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
DLCI LIST (MAX 32): 19 20 30 54 60 100 210 221 233
256 315
FRL ABSOLUTE NR.: 11
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
INTERNAL TIMESLOT MAP: 66 67
SPEED: 128 KB/S
TX LOAD %: 10 20 30 35 40 45 50 55 60 70 80
RX LOAD %: 1
CRC LAST 5 MIN: 5
INVALID LAST 5 MIN: 2 5 1 2 5 1
INVALID DLCI LAST 5 MIN: 1
DLCI LIST (MAX 32): 71
ATTESTED BVCI LIST: 2 3 4 5 6 10 30 35 37 39
100 101 102 103 104 105 300 350 351 359
END OF REPORT
Layout PCU with IPV4 configuration
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: PROVIDING_SERVICE
PROCEDURAL STATUS: NONE
EFC SUPPORTED: TRUE
EFC STATUS: ENABLED
NSEI: 12
HW VERSION: PPXU_V2
GBSNS: IPV4


A30808-X3247-M230-6-7619

881
CML:BSC PCU
Id:0900d805800d429f
NSVC CONFIG: STATIC
PDT NR. INT.TSL NR. BVCI NR. BTSM NR. BTS NR. TRX NR.
0 0 2 0 0 0
...; ...; ...; ...; ...; ...; ...; ...; ...; ...; ...; ...;
399 1 3 1 1 0
PDT NR. CHAN NR. TYPE USAGE RESYNC COUNT.
0 2 PCCCH IDLE 0
...; ...; ...; ...; ...; ...; ...; ...; ...;
399 6 PBCCH IDLE 0
PCU IP ADDRESS 0: 123.123.123.123
PCU IP ADDRESS 1: 123.123.123.1
NSVLIP 0:
ADMINISTRATIVE STATE: LOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
IP PORT: 1
UDP PORT: 8038
WEIGHT DATA: 6
WEIGHT SIGNALLING: 5
NSVCIP 0:
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
REMOTE IP ADDRESS: 123.34.78.123
REMOTE UDP PORT: 1040
REMOTE WEIGHT DATA: 6
REMOTE WEIGHT SIGNALLING: 5
COUNTER INFORMATION:
SYNT: : 3333 2222 4444
SEMANTIC: 3333 1111 4444 6666
ERR EVT: 3333
NON ERR EVT: 3333 1111


882 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
OTHER ERR EVT: 3333 1111 2222 4444 5555 6666
...;...;..
NSVCIP 15:
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
REMOTE IP ADDRESS: 123.34.67.123
REMOTE UDP PORT: 1041
REMOTE WEIGHT DATA: 6
REMOTE WEIGHT SIGNALLING: 5
COUNTER INFORMATION:
SYNT: : 3333 2222 4444
SEMANTIC: 3333 1111 4444 6666
ERR EVT: 3333
NON ERR EVT: 3333 1111
OTHER ERR EVT: 3333 1111 2222 4444 5555 6666
NSVLIP 15:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: DISABLED
AVAILABILITY STATUS: DEPENDENCY
CONTROL STATUS: NONE
IP PORT: 1
UDP PORT: 8038
WEIGHT DATA: 6
WEIGHT SIGNALLING: 5
NSVCIP 240:
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
REMOTE IP ADDRESS: 123.35.68.123
REMOTE UDP PORT: 2345
REMOTE WEIGHT DATA: 6
REMOTE WEIGHT SIGNALLING: 5
COUNTER INFORMATION:
SYNT: : 3333 2222 4444
SEMANTIC: 3333 1111 4444 6666


A30808-X3247-M230-6-7619

883
CML:BSC PCU
Id:0900d805800d429f
ERR EVT: 3333
NON ERR EVT: 3333 1111
OTHER ERR EVT: 3333 1111 2222 4444 5555 6666
NSVCIP 255:
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
REMOTE IP ADDRESS: 123.35.8.123
REMOTE UDP PORT: 2347
REMOTE WEIGHT DATA: 6
REMOTE WEIGHT SIGNALLING: 5
COUNTER INFORMATION:
SYNT: : 3333 2222 4444
SEMANTIC: 3333 1111 4444 6666
ERR EVT: 3333
NON ERR EVT: 3333 1111
OTHER ERR EVT: 3333 1111 2222 4444 5555 6666
ATTESTED BVCI LIST: 2 3 4 5 6 10 30 35 37 39
100 101 102 103 104 105 300 350 351 359
END OF REPORT
- Operation Failed
GETINFO PCU NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PCU:
name = PCU:0
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


884 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
Application Guidelines:
None.
Example of Command Execution:
Getinfo PCU:NAME=PCU:0;
GETRELATIONSHIP PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU GETRELATIONSHIP PCU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the PCU object the related HMOs are the following: EPWR, PWRD, MPCC, TDPC,
MEMT, NTW and PPXU.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
PCU
NAME=PCU:0..11;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

885
CML:BSC PCU
Id:0900d805800d429f
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PCU:NAME=PCU:0;
GETSUBO PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU GETSUBO PCU
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PCU:NAME=PCU:0;
LOCK PCU
GETSUBO PCU NAME=PCU:0..11;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK PCU NAME=PCU:0..11;


886 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU LOCK PCU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Locked".
The PCU object becomes DISABLED - Not initialized, while all the subordinated units
shall be put in Disabled - Dependency/offline status: on one side the the PTPPKF,
directly subordinated to PCU, and on the other the FRL and NSVC. This implies the
activation of blocking procedure for NSVC objects towards SGSN.
The appropriate system information informing MS about unavailability of the GPRS
service in the cell, supported by the PCU, shall be sent. The command can cuase
services interruption.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PCU:NAME=PCU:0;
INVALID_STATUS
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.


A30808-X3247-M230-6-7619

887
CML:BSC PCU
Id:0900d805800d429f
SET PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU SET PCU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the PCU object class.
To change NSEI and NMO parameters, the PCU must be LOCKED and the same check
like create must be done. In this case the command is not forwarded to PCU because
at unlock all the configuration is reloaded. To set the other attributes the PCU object
could remain unlocked.
Long Names:
NAME Addres of the managed object
NMO networkModeOfOperation
NSEI networkServiceElementIdentifier
TNSVCBLK timerInNsvcBlockProcedure
NNSVCBLKR numberOfNsvcBlockRetries
NNSVCUBLR numberOfNsvcUnblockRetries
TNSVCR timerInNsvcResetProcedure
NNSVCRR numberOfNsvcResetRetries
TNSVCTST timerInNsvcTestProcedure
TNSVCPTST timerInNsvcPeriodicTestProcedure
NNSVCTSTR numberOfNsvcTestRetries
THPROXT thresholdProximityTimer
PFCFCSUP packetFlowContextFlowControlSupport
PFCSUP pfcSupport
SET PCU NAME=PCU:0..11 [,NMO=] [,NSEI=] [,TNSVCBLK=] [,NNS-
VCBLKR=] [,NNSVCUBLR=] [,TNSVCR=] [,NNSVCRR=]
[,TNSVCTST=] [,TNSVCPTST=] [,NNSVCTSTR=]
[,THPROXT=] [,PFCFCSUP=] [,PFCSUP=] [,BEPFITODIFF-
SERV=] [,SPFITODIFFSERV=] [,SMSPFITODIFFSERV=]
[,STREAMTODIFFSERV=] [,BCGRTODIFFSERV=]
[,INTRTRFH1TODIFFSERV=]
[,INTRTRFH2TODIFFSERV=]
[,INTRTRFH3TODIFFSERV=] [,CPCUN=] [,STREAMSUP=]
[,GBSNS=] [,TYPOFNSVCCONF=] [,TSNPRO=] [,SNSSIZ-
ERET=] [,SNSCONFRET=] [,SNSADDRET=] [,SNSDEL-
RET=] [,SNSCHWEIRET=] [,PORT<n>=] [,MTU=]
[,DIFFSERVSUP=] [,STPIPEP=];


888 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
BEPFITODIFFSERV bestEffortPFIToDiffserv
SPFITODIFFSERV signallingPFIToDiffserv
SMSPFITODIFFSERV smsPFIToDiffserv
STREAMTODIFFSERV streamingToDiffserv
BCGRTODIFFSERV backgroundToDiffserv
INTRTRFH1TODIFFSERV interactiveTrafficHandlingPrio1ToDiffserv
INTRTRFH2TODIFFSERV interactiveTrafficHandlingPrio2ToDiffserv
INTRTRFH3TODIFFSERV interactiveTrafficHandlingPrio3ToDiffserv
CPCUN commonPCUNumber
STREAMSUP streamingSupport
GBSNS gBSubNetworkService
TYPOFNSVCCONF typeOfNSVCConfiguration
TSNPRO timeSubnetworksProcedure
SNSSIZERET subnetworksSizeRetries
SNSCONFRET subnetworksConfigRetries
SNSADDRET subnetworksAddRetries
SNSDELRET subnetworksDeleteRetries
SNSCHWEIRET sNSChangeWeigthRetries
PORT<n> port<n>
MTU mtu
DIFFSERVSUP differentServiceSupport
STPIPEP startupRemoteIPEndpoint
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The NSEI attribute can be set only if the PCU is in
LOCKED state.
In order to modify PFCSUP attribute, the PCU must
be locked.
In order to set the PFCFCSUP attribute the PCU must
be locked.
In order to modify the cpcun value, the PCU must be
locked.


A30808-X3247-M230-6-7619

889
CML:BSC PCU
Id:0900d805800d429f
In order to set the GBSNS, TYPOFNSVCCONF, MTU
and STPIPEP attributes the PCU must be locked.
n order to set the PORT0, PORT1 or STPIPEP
attributes the related NSVLIP must be locked.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Different PCU instances must have different NSEI
values.
In order to set PFCSUP value to DISABLED, the
PFCFCSUP value must be DISABLED.
In order to set PFCSUP value to ENABLED, the
SISGSNREL99 value must be ENABLED.
The attribute PFCFCSUP can be set to TRUE only if
PFCSUP is enabled.
If the GBSNS attribute is set to a value different from
IPV4 the following attributes must be set to <NULL>:
TYPOFNSVCCONF, TSNSPRO, SNSSIZERET,
SNSCONFRET, SNSADDRET, SNSDELRET,
SNSCHWEIRET, PORT0, PORT1, MTU, DIFFSERV-
SUP.
If the GBSNS attribute is set to IPV4 the following
attributes must be set to a value different from
<NULL>: TYPOFNSVCCONF, TSNSPRO, SNSSIZ-
ERET, SNSCONFRET, SNSADDRET, SNSDELRET,
SNSCHWEIRET, PORT0, PORT1, MTU, DIFFSERV-
SUP.
The value of PORT0, PORT1 and the field IPAddress
of STPIPEP must be valid IP address.
The PORT0 and PORT1 cannot be set with the same
IP address.
The STPIPEP attribute must be set to NULL if the
TYPOFNSVCCONF attribute is set to a value different
from DYNAMIC. The STPIPEP attribute must be set
to a value different from NULL if the TYPOFNSVC-
CONF attribute is set to DYNAMIC.
If the GBSNS attribute is set to IPV4 the following
attributes must be set to <NULL>: NNSVCBLKR,
NNSVCUBLR, NNSVCRR, TNSVCBLK, TNSVCR.
If the GBSNS attribute is set to a value different from
IPV4 the following attributes must be set to a value dif-
ferent from <NULL>: NNSVCBLKR, NNSVCUBLR,
NNSVCRR, TNSVCBLK, TNSVCR.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The related CPCU doesn't exist.


890 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d429f
PCU
Application Guidelines:
1. In case of trouble on redundant NSVC links created on the Gb interface, it could
happen that PTPPKF object is disabled while NSVC is still enabled. In order to avoid
this situation the following rule has to be followed:
TF1*"number of flow control retries" > TNSVCTST + TNSVCPTST*NNSVCTSTR.
The "number fo flow control retries" is not manageable by operator and is fixed to 15.
Default values of all the above attributes are in according with the rule.
2. The NMO value must be the same for all PCUs; it is a task of the operator to guar-
antee this condition.
Example of Command Execution:
Set PCU:NAME=PCU:0,NMO=2,NSEI=40,TNSVCBLK=3,NNSVCBLKR=25,
NNSVCUBLR=7,TNSVCR=6,NNSVCRR=32,TNSVCTST=20,TNSVCPTST=5,
NNSVCTSTR=20,THPROXT=30-90-120,PFCFCSUP=FALSE,CPCUN=0;
UNLOCK PCU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU UNLOCK PCU
The GBSNS attribute cannot be set to IPV4 if the
couple of superordinate GBIPLNK are not already
equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The last PCU related to a CPCU cannot be removed
if a PTPPKF is equipped under that CPCU.
If a PTPPKF exists under a CPCU at least one NSVC
must be equipped under that CPCU.
The GBSNS attribute cannot be set to IPV4 if there is
at least one subordinate FRL equipped.
The GBSNS attribute cannot be set to a value differ-
ent from IPV4 if there is at least one subordinate
NSVLIP equipped.
If the TYPOFNSVCCONF attribute is set to DYNAMIC
no subordinate RNSVLIP can be equipped.
The last PCU over IP of a CPCU can be deleted only
if there are no PTPPKFs equipped or if a NSVC exists
under that CPCU.
UNSUCCESSFUL_LINK_CONNECTED
The PORT0 or PORT1 cannot be set to <NULL> if it
is referenced by a NSVLIP.
UNLOCK PCU NAME=PCU:0..11;


A30808-X3247-M230-6-7619

891
CML:BSC PCU
Id:0900d805800d429f
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command removes the operator block and the unit is reloaded of configuration
data: the operational state is Disabled - Not Initialized - Initializing.
When the PCU will be enabled, the system information shall be sent on BCCH channel
in order to inform all MS that the service is available in the cell supported by this PCU.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_INVALID_STATUS
Application Guidelines:
None.
Example of Command Execution:
Unlock PCU:NAME=PCU:0;


892 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
PPXL
The PPXL object represents the high-capacity peripheral processor for LAPD and
CCSS#7.
GET PPXL STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GET PPXL STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PPXL object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get PPXL STAT:NAME=PPXL:0;
GET PPXL STAT NAME=PPXL:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in
order to perform the command.


A30808-X3247-M230-6-7619

893
CML:BSC PPXL
Id:0900d805800d42a2
GETINFO PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETINFO PPXL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The "RSU running" object and the "RSU version".
2. The firmware version.
3. The states and statuses of the PPXL: AST, OST, AVS, CST, PRS.
4. The software inside the board; the available states are: LOAD_REQUIRED,
LOADED, INSERVICE, OOS_IDLE and OOS_FAULTED.
5. The operational data of the PPXL processor: real time, current OS time, OS time of
last Task init, type and OS time of the last exception, number of task init from last
Bring-up, number of exceptions since last Bring-up init and number of exceptions
since last Task init, all dynamic memory pool type (the used and total buffer numbers
from pool 0 to pool B) and the total and largest block available.
6. A single sweep "photograph" of the bits that are transmitted by the PPXL at a certain
random instant.
7. A single sweep "photograph" of the bits that are received by the PPXL at a certain
random instant.
8. For each physical handled lapd:
the lapd type and number
the operational state
the availability status
the standby status
the lapd baud rate.
the pcm location where the lapd has been configured
the hdlc circuit
the internal time slot and sub-time slot of the lapd inside the PPXL
the hdlc state: FLAG or NO FLAG.
9. For each SS7 link handled:
the ss7 number
the operational state
the availability status
the pcm location where the ss7 has been configured
GETINFO PPXL NAME=PPXL:0..1;


894 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
the hdlc circuit
the internal time slot of the ss7 inside the PPXL
the hdlc state: FLAG or NO FLAG.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO PPXL ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GETINFO REPORT PPXL:
NAME = PPXL:0
RSU RUNNING: RSUEXE 2-1
RSU VERSION: 02-06-01-00-00_01-10-09
FW VERSION: SFP1101
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
SOFTWARE STATE: IN SERVICE
PENTIUM PROCESSOR:
REAL TIME LOAD: 31%
CURRENT OS TIME: 0049:05:54
OS TIME OF LAST TASK INIT: 0000:00:00
OS TIME OF LAST EXCEPTION: 0000:00:00
TYPE OF LAST EXCEPTION: 244
NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001
NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000
NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000

DYNAMIC MEMORY USAGE:
0: 0017/0031 1: 0057/1000 2:0109/0640 3: 0109/0300


A30808-X3247-M230-6-7619

895
CML:BSC PPXL
Id:0900d805800d42a2
4: 0017/0200 5: 0000/0150 6:0000/0100 7: 0001/1000
8: 0001/0300 9: 0000/0050 A:0000/0150 B: 0000/0100

TOTAL AND LARGEST BLOCK AVAILABLE: 0000000001/02234400

PPXL LINE TX SAMPLES:
FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF

PPXL LINE RX SAMPLES:
FA FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF

LPDLM 0 - 0:
LAPD POOL: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: PROVIDING SERVICE
HDLC CIRCUIT BAUD RATE: RATE16KB
ABIS/ASUB TIMESLOT: 3-10-0 (PCM NR - TS NR - SUBTS NR)
HDLC CIRCUIT: 1
PPXL TIMESLOT: 10-3 (TS NR - SUBTS NR)
HDLC STATE: FLAG

LPDLM 0 - 1:
LAPD POOL: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: HOT STANDBY
HDLC CIRCUIT BAUD RATE: RATE64KB
ABIS/ASUB TIMESLOT: 2-7 (PCM NR - TS NR - SUBTS NR)
HDLC CIRCUIT: 9
PPXL TIMESLOT: 12 (TS NR - SUBTS NR)


896 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
HDLC STATE: FLAG

... ...
LPDLM 200 - 1:
LAPD POOL: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: PROVIDING SERVICE
HDLC CIRCUIT BAUD RATE: RATE16KB
ABIS/ASUB TIMESLOT: 13-16-1 (PCM NR - TS NR - SUBTS NR)
HDLC CIRCUIT: 4
PPXL TIMESLOT: 13-2 (TS NR - SUBTS NR)
HDLC STATE: FLAG

SS7L 0:
OPERATIONAL STATE: DISABLED
AVAILABILITY STATUS: FAILED
ASUB TIMESLOT: 4-15 (PCM NR - TS NR)
HDLC CIRCUIT: 240
PPXL TIMESLOT: 6
HDLC STATE: NO FLAG

SS7L 1:
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
ASUB TIMESLOT: 4-16 (PCM NR - TS NR)
HDLC CIRCUIT: 241
PPXL TIMESLOT: 127
HDLC STATE: FLAG

END OF REPORT
- Operation Failed
GETINFO PPXL NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PPXL:


A30808-X3247-M230-6-7619

897
CML:BSC PPXL
Id:0900d805800d42a2
name = PPXL:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
1. Only equipped LPDLX links (LPDLM/R/S) should be displayed.
2. Only equipped SS7 links should be displayed.
Example of Command Execution:
Getinfo PPXL:NAME=PPXL:0;
GETRELATIONSHIP PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETRELATIONSHIP
PPXL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.

For the PPXL object the BTS, TRAU, PCMA, LPDLS, LPDLM, BTSM and SS7L are the
related FMOs.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
PPXL
NAME=PPXL:0..1;


898 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PPXL:NAME=PPXL:0;
GETSUBO PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETSUBO PPXL
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object instance does not provide any relationship attribute.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in order to
perform the command.
GETSUBO PPXL NAME=PPXL:0..1;


A30808-X3247-M230-6-7619

899
CML:BSC PPXL
Id:0900d805800d42a2
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PPXL:NAME=PPXL:0;
GETTEST PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL GETTEST PPXL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already
created in order to perform the command.
GETTEST PPXL NAME=PPXL:0..1;
GETTEST PPXL:NAME=PPXL:0;
name = TEST:<n>
mOts = PPXL:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor


900 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest PPXL:NAME=PPXL:0;
LOCK PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL LOCK PPXL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
This command causes the board reset, so the RAM contents will be lost. All the
LPDL(M/R/S) and the SS7L running on the locked PPXL are switched to the other
PPXL, whereby the LAPD links will be temporary disconnected and a "Fast Alignment"
will follow. The lock of PPXL does not cause the drop of the established calls, however
the currently signalling processes (call setup and hand over) on the LAPD channels will
be interrupted.
For BTSM with only one subordinated LPDLM the Fast Alignment must be actually over
before performing any command or an UNLOCK PPXL (which will cause another Fast
Alignment), to avoid the possibility that the alignment gets "Full" when the create provid-
ing service LPDLM procedure is not completely ended.
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK PPXL NAME=PPXL:0..1;


A30808-X3247-M230-6-7619

901
CML:BSC PPXL
Id:0900d805800d42a2
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
3. The LOCK of both PPXL objects leads to an interruption of the whole BSS call traffic.
The LOCK command for the second board is not refused and there is no system
warning generation.
Example of Command Execution:
Lock PPXL:NAME=PPXL:0;
PERFTEST PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL PERFTEST PPXL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected PPXL object; the test consist of
the following phases:
Board reset and FW self-test (start phase),
MPCC & TDPC Duam Test (WP1),
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in
order to perform the command.
PERFTEST PPXL NAME=PPXL:0..1;


902 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
Internal Circuit Test (WP2),
ABIC Test (WP3),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST PPXL:NAME=PPXL:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase. phaseId =
....
skippedPhases


A30808-X3247-M230-6-7619

903
CML:BSC PPXL
Id:0900d805800d42a2
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
3. During the execution of the command PERFTEST on the board PPXL, the system
verify the presence of a firmware file stored in the BSC disk and related to the board,
if a file is present it performs the verification of the loaded Firmware version towords
the Firmware file, if the version differs then it automatically proceeds to the updating.
The Firmware file must be stored in a dedicated directory structure created using
Creatdir commands and stored using using dnlFile commands.
Example of Command Execution:
Perftest PPXL:NAME=PPXL:0;
STOPTEST PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL STOPTEST PPXL
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests are possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
STOPTEST PPXL NAME=PPXL:0..1;


904 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STOPTEST PPXL:NAME=PPXL:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = PPXL:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST


A30808-X3247-M230-6-7619

905
CML:BSC PPXL
Id:0900d805800d42a2
Application Guidelines:
None.
Example of Command Execution:
Stoptest PPXL:NAME=PPXL:0;
UNLOCK PPXL
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXL UNLOCK PPXL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
If the PPXL is not loaded (in this case it is in "disabled-not initialized" state), a SW load
will start automatically on the PPXL. The LPDL(M/R/S) and the SS7L that in the BSC
database are associated to the PPXL are switched to this PPXL from the other one,
whereby the LAPD links will be temporary disconnected and a "Fast Alignment" will
follow. The unlock of PPXL does not cause the drop of the established calls, however
the currently signalling processes (call setup and hand over) on the LAPD channels will
be interrupted.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNLOCK PPXL NAME=PPXL:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


906 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a2
PPXL
Application Guidelines:
It is possible to unlock the PPXL card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock PPXL:NAME=PPXL:0;
The instance of the object must not be already created in
order to perform the command.


A30808-X3247-M230-6-7619

907
CML:BSC PPXU
Id:0900d805800d42a5
PPXU
The PPXU object represents the high-capacity peripheral processor for PCU.
GET PPXU STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GET PPXU STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PPXU object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get PPXU STAT:NAME=PPXU:0;
GET PPXU STAT NAME=PPXU:0..11;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in
order to perform the command.


908 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a5
PPXU
GETINFO PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETINFO PPXU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The report complete indicator.
2. The "RSU running" object and the "RSU version".
3. The FW version.
4. The HW version (values are PPXY_V1 or PPXY_V2).
5. MAC0 and MAC1 (present and meaningful only if the HW version is equal to
PPXY_V2).
6. The states and statuses of the PPXU: AST, OST, AVS, CST, PRS.
7. The software inside the board; the available states are: LOAD_REQUIRED,
START_REQUIRED, IN_SERVICE, OUT_OF_SERV_IDLE and
OUT_OF_SERV_FAULTED.
8. The operational data of the PPXU processor: real time, current OS time, OS time of
last Task init, type and OS time of the last exception, number of task init from last
Bring-up, number of exceptions since last Bring-up init and number of exceptions
since last Task init, all dynamic memory pool type (the used and total buffer numbers
from pool 0 to pool B) and the total and largest block available.
9. A single sweep "photograph" of the bits that are transmitted by the PPXU at a certain
random instant.
10. A single sweep "photograph" of the bits that are received by the PPXU at a certain
random instant.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO PPXU ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GETINFO REPORT PPXU:
PPXU :0
GETINFO PPXU NAME=PPXU:0..11;


A30808-X3247-M230-6-7619

909
CML:BSC PPXU
Id:0900d805800d42a5
REPORT COMPLETE: TRUE
RSU RUNNING: RSUEXE 2-1
RSU VERSION: 02-06-01-01-00-00_01-10-09
FW VERSION: SFP1101
HW VERSION: PPXY_V2
MAC 0: 12:34:56:78:9A:BC
MAC 1: 12:34:56:78:9A:BE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
PROCEDURAL STATUS: NONE
SOFTWARE STATE: IN SERVICE
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678
901234567890
PENTIUM PROCESSOR:
REAL TIME LOAD: 31%
CURRENT OS TIME: 0049:05:54
OS TIME OF LAST TASK INIT: 0000:00:00
OS TIME OF LAST EXCEPTION: 0000:00:00
TYPE OF LAST EXCEPTION: 244
NUMBER OF TASK INIT SINCE LAST BRING-UP: 0001
NUMBER OF EXCEPTIONS SINCE LAST BRING-UP INIT: 0000
NUMBER OF EXCEPTIONS SINCE LAST TASK INIT: 0000
DYNAMIC MEMORY USAGE:
0: 0017/0031 1: 0057/1000 2: 0109/0640 3: 0109/0300 4: 0017/0200
5: 0000/0150 6: 0000/0100 7: 0001/1000 8: 0001/0300 9: 0000/0050
A: 0000/0150 B: 0000/0100
TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/02234400
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678
901234567890


910 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a5
PPXU
PPXU LINE TX SAMPLES:
FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
PPXU LINE RX SAMPLES:
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FA BC DF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF E7 7E FC 3F FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
END OF REPORT
- Operation Failed
GETINFO PPXU NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PPXU:
name = PPXU:0
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

911
CML:BSC PPXU
Id:0900d805800d42a5
Application Guidelines:
None.
Example of Command Execution:
Getinfo PPXU:NAME=PPXU:0;
GETRELATIONSHIP PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETRELATIONSHIP
PPXU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.

For the PPXU object the PCU is the related FMOs.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GETRELATIONSHIP
PPXU
NAME=PPXU:0..11;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object instance does not provide any relationship attribute.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in order to
perform the command.


912 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a5
PPXU
Example of Command Execution:
Getrelationship PPXU:NAME=PPXU:0;
GETSUBO PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETSUBO PPXU
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PPXU:NAME=PPXU:0;
GETTEST PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU GETTEST PPXU
GETSUBO PPXU NAME=PPXU:0..11;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already
created in order to perform the command.
GETTEST PPXU NAME=PPXU:0..11;


A30808-X3247-M230-6-7619

913
CML:BSC PPXU
Id:0900d805800d42a5
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GETTEST PPXU:NAME=PPXU:0;
name = TEST:<n>
mOts = PPXU:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


914 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a5
PPXU
Example of Command Execution:
Gettest PPXU:NAME=PPXU:0;
LOCK PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU LOCK PPXU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PPXU:NAME=PPXU:0;
LOCK PPXU NAME=PPXU:0..11;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in
order to perform the command.


A30808-X3247-M230-6-7619

915
CML:BSC PPXU
Id:0900d805800d42a5
PERFTEST PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU PERFTEST PPXU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to perform a test on the selected PPXU object; the test consists
of the following phases:
Board reset and FW self-test (start phase),
MPCC & TDPC Duam Test (WP1),
Internal Circuit Test (WP2),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST PPXU NAME=PPXU:0..11;
PERFTEST PPXU:NAME=PPXU:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:


916 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a5
PPXU
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the "Locked"
state, if the diagnostic is intrusive.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests are possible.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.


A30808-X3247-M230-6-7619

917
CML:BSC PPXU
Id:0900d805800d42a5
3. During the execution of the command PERFTEST on the board PPXU, the system
verify the presence of a firmware file stored in the BSC disk and related to the board,
if a file is present it performs the verification of the loaded Firmware version towords
the Firmware file, if the version differs then it automatically proceeds to the updating.
The Firmware file must be stored in a dedicated directory structure created using
Creatdir commands and stored using using dnlFile commands.
Example of Command Execution:
Perftest PPXU:NAME=PPXU:0;
STOPTEST PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU STOPTEST PPXU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
STOPTEST PPXU NAME=PPXU:0..11;
STOPTEST PPXU:NAME=PPXU:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = PPXU:0
testTermination = Cancel
executedPhases


918 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42a5
PPXU
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Stoptest PPXU:NAME=PPXU:0;
UNLOCK PPXU
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PPXU UNLOCK PPXU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.
UNLOCK PPXU NAME=PPXU:0..11;


A30808-X3247-M230-6-7619

919
CML:BSC PPXU
Id:0900d805800d42a5
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the PPXU card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock PPXU:NAME=PPXU:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must not be already created in
order to perform the command.


920 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
PTPPKF
The PTPPKF functional object represents the point to point service in a cell. In GSM
08.18, for point to point packet transfer, it is specified that a cell is identified by a BVCI
so there is a one to one relation between cell and BVCI.
CREATE PTPPKF
CREATE PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0 ,RACODE=
,RACOL= [,BSCDVMA=] [,PKTNDEC=] [,PKTNINC=] [,PKT-
NMA=] [,GRXLAMI=] [,GMSTXPMAC=] [,ABUTYP=]
[,RAARET=] [,GPATH=] [,GTXINT=] [,GS=] [,GMANRETS=]
[,GMANMSAL=] [,T3168=] [,T3192=] [,INICSCH=] [,GCELL-
RESH=] [,C31H=] [,C32QUAL=] [,TRESEL=] [,RARESH=]
[,GHCSTH=] [,GHCSPC=] [,ALPHA=] [,TAVGW=]
[,TAVGT=] [,PRPBCCH=] [,PCMECH=] [,NAVGI=] [,BSPB-
BLK=] [,BPAGCHR=] [,BPRACHR=] [,DRXTMA=] [,CACK-
TYP=] [,GAM=] [,GASTRTH=] [,GPDPDTCHA=]
[,QSRHPRI=] [,FDDGQO=] [,GMANPRESPRM=] [,GMAN-
PRESCOM=] [,EMANPRESPRM=] [,EMANPRESCOM=]
[,TRFPSCTRLT=] [,NTWCREPPTR=] [,NTWCREPPIDL=]
[,NTWCNDRXP=] [,CRESELTRHSOUT=] [,GUMTSS-
RHPRI=] [,GFDDQMI=] [,TDDGQO=] [,GFDDREPQTY=]
[,GNMULBAC=] [,GFDDMURREP=] [,GTDDMURREP=]
[,CSCH3CSCH4SUP=] [,BVCBSPPER=] [,BVCBHIPER=]
[,BVCBMAPER=] [,BVCBLPER=] [,MSBSPPER=] [,MSB-
HIPER=] [,MSBMAPER=] [,MSBLPER=] [,ELKADPT=]
[,BLERAVEUL=] [,BLERAVEDL=] [,EMFA1UNIR8PSK=]
[,EMFAP1UNIR8PSK=] [,EMFB1UNIR8PSK=]
[,EMFCUNIR8PSK=] [,EMFGUNIR8PSK=] [,EMFCUNIR-
GMSK=] [,EMFGUNIRGMSK=] [,EMCSFAMA1DL=]
[,EMCSFAMAP1DL=] [,EMCSFAMB1DL=] [,EMCSFAM-
CDL=] [,EMCSFAMGDL=] [,IMCSULNIR8PSK=] [,IMC-
SULNIRGMSK=] [,INIMCSDL=] [,RAENV=]
[,STGTTLLIINF=] [,INIBLER=] [,SCHWEIPRI1=]
[,SCHWEIPRI2=] [,SCHWEIPRI3=] [,SCHWEIPRI4=] [,EBC-
CHTRX=] [,EEDGE=] [,EGPRS=] [,BEPAVGP=] [,EGWSO-
NETS=] [,EGWSTWOTS=] [,EGWSTHREETS=]
[,EGWSFOURTS=] [,EGWSFIVETS=] [,EGWSSIXTS=]
[,EGWSSEVENTS=] [,EGWSEIGHTTS=] [,EGPLGPO-
NETS=] [,EGPLGPTWOTS=] [,EGPLGPTHREETS=]
[,EGPLGPFOURTS=] [,EGPLGPFIVETS=]
[,EGPLGPSIXTS=] [,EGPLGPSEVENTS=] [,EGPLG-
PEIGHTTS=] [,PERSTLVPRI<n>=] [,NCC1TH=]
[,NCRARESH=] [,NCSARA=] [,NCTRFPSCTH=] [,CRE-
SELTRHINP=] [,PKTMEASREPCNT=] [,MSRMAXU=]
[,FPER=] [,PFCIBMAPER=] [,PFCIBMAPPER=] [,PFCIB-
HIPER=] [,PFCIBLPER=] [,PFCBBMAPER=] [,PFCBBMAP-
PER=] [,PFCBBHIPER=] [,PFCBBLPER=]


A30808-X3247-M230-6-7619

921
CML:BSC PTPPKF
Id:0900d805800d5658
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF CREATE
PTPPKF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the PTPPKF object class. It can be done only if
the super-ordinate BTS and all the necessary NSVCs (at least one) are created.
Creation of PTPPKF object means allowing GPRS service in a specific cell.
The information to the mobile about the GPRS service in the network are provided via
system information. The status at creation will be Locked-Disabled/Offline.
On the created PTPPKF, a BVCI reset procedure is performed toward SGSN. After a
positive termination of the procedure, the PTPPKF shall became Locked-Enabled and
a block procedure is necessary to reflect the locked condition.
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
RACOL routingAreaColour
BSCDVMA bsCountdownValueMax
PKTNDEC packetNumberDecrement
PKTNINC packetNumberIncrement
PKTNMA packetNumberMax
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
ABUTYP accessBurstType
RAARET randomAccessRetry
GPATH gprsPriorityAccessThreshold
GTXINT gprsTxInterval
GS gprsSlot
GMANRETS gprsMaxNumberRetransmission
GMANMSAL gprsMaxNumberMsAllocated
CREATE PTPPKF [,PFCSBMAPER=] [,PFCSBMAPPER=] [,PFCSBHIPER=]
[,PFCSBLPER=] [,PFCIRMAXU=] [,PFCBRMAXU=] [,PFC-
SRMAXU=] [,PFCIRPER=] [,PFCBRPER=] [,PFCSRPER=]
[,TFAILNCU=] [,MAFAILNCU=] [,TBNCU=] [,EUMSSNCRE-
SEL=] ,CPCUN= [,BCGRWEI=] [,BEPFIDLWEI=]
[,INTRTRFH1WEI=] [,INTRTRFH2WEI=]
[,INTRTRFH3WEI=] [,SPFIWEI=] [,SMSINFO=] [,STREAM-
WEI=] [,EDASUP=] [,GFDDRSCPMI=] [,GFDDQMIO=]
[,EDTMSUP=] [,LLCDVOLTRSH=];


922 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
T3168 t3168
T3192 t3192
INICSCH initialCodingScheme
GCELLRESH gprsCellReselectHysteresis
C31H c31Hysteresis
C32QUAL c32Qualifier
TRESEL timerReselection
RARESH routingAreaReselectHysteresis
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
ALPHA alpha
TAVGW tAverageWeight
TAVGT tAverageTime
PRPBCCH powerReductionOnPbcch
PCMECH powerControlMeasurementChannel
NAVGI nAverageInterference
BSPBBLK bsPbcchBlocks
BPAGCHR bsPagchBlocksReserved
BPRACHR bsPrachBlocksReserved
DRXTMA discontinousReceptionTimerMax
CACKTYP controlAcknowledgementType
GAM gamma
GASTRTH gprsAllocationStrategyThresholds
GPDPDTCHA gprsPercentageOfDynamicPdtchAvailable
QSRHPRI qSearchPriority
FDDGQO fddGPRSQOffset
GMANPRESPRM gprsMaxNumberPDCHResPrimary
GMANPRESCOM gprsMaxNumberPDCHResComplementary
EMANPRESPRM edgeMaxNumberPDCHResPrimary
EMANPRESCOM edgeMaxNumberPDCHResComplementary
TRFPSCTRLT trafficPSControlTimer
NTWCREPPTR networkControlReportPeriodTransfer
NTWCREPPIDL networkControlReportPeriodIdle
NTWCNDRXP networkControlNonDRXPeriod
CRESELTRHSOUT cellReselectionThresholdOutput
GUMTSSRHPRI gprsUmtsSearchPriority
GFDDQMI gprsFddQMin
TDDGQO tddGprsQOffset
GFDDREPQTY gprsFddReportingQuantity


A30808-X3247-M230-6-7619

923
CML:BSC PTPPKF
Id:0900d805800d5658
GNMULBAC gprsNMultibandCell
GFDDMURREP gprsFddMultiratReporting
GTDDMURREP gprsTddMultiratReporting
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
BVCBSPPER bvcBucketSizePcuPercentage
BVCBHIPER bvcBucketHighPercentage
BVCBMAPER bvcBucketMaxPercentage
BVCBLPER bvcBucketLowPercentage
MSBSPPER msBucketSizePcuPercentage
MSBHIPER msBucketHighPercentage
MSBMAPER msBucketMaxPercentage
MSBLPER msBucketLowPercentage
ELKADPT enableLinkAdaptation
BLERAVEUL blockErrorRateAveragingPeriodUplink
BLERAVEDL blockErrorRateAveragingPeriodDownlink
EMFA1UNIR8PSK enMcsFamAMcs1UplinkWoutIncrRed8Psk
EMFAP1UNIR8PSK enMcsFamApMcs1UplinkWoutIncrRed8Psk
EMFB1UNIR8PSK enMcsFamBMcs1UplinkWoutIncRed8Psk
EMFCUNIR8PSK enMcsFamCUplinkWoutIncRed8Psk
EMFGUNIR8PSK enMcsFamGmskUplinkWoutIncRed8Psk
EMFCUNIRGMSK enMcsFamCUplinkWoutIncrRedGmsk
EMFGUNIRGMSK enMcsFamGmskUplinkWoutIncrRedGmsk
EMCSFAMA1DL enMcsFamAMcs1Downlink
EMCSFAMAP1DL enMcsFamAPaddingMcs1Downlink
EMCSFAMB1DL enMcsFamBMcs1Downlink
EMCSFAMCDL enMcsFamCDownlink
EMCSFAMGDL enMcsFamGmskDownlink
IMCSULNIR8PSK initialMcsUplinkWoutIncrRed8psk
IMCSULNIRGMSK initialMcsUplinkWoutIncrRedGmsk
INIMCSDL initialMcsDownlink
RAENV radioEnvironment
STGTTLLIINF storageTimeTLLIInfo
INIBLER initialBLER
SCHWEIPRI1 schedulingWeightOfPriority1
SCHWEIPRI2 schedulingWeightOfPriority2
SCHWEIPRI3 schedulingWeightOfPriority3
SCHWEIPRI4 schedulingWeightOfPriority4
EBCCHTRX egprs8pskOnBcchTrx
EEDGE enableEdge


924 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
EGPRS enableGprs
BEPAVGP bitErrorProbabilityAveragePeriod
EGWSONETS egprsWindowSizeOneTimeSlot
EGWSTWOTS egprsWindowSizeTwoTimeSlot
EGWSTHREETS egprsWindowSizeThreeTimeSlot
EGWSFOURTS egprsWindowSizeFourTimeSlot
EGWSFIVETS egprsWindowSizeFiveTimeSlot
EGWSSIXTS egprsWindowSizeSixTimeSlot
EGWSSEVENTS egprsWindowSizeSevenTimeSlot
EGWSEIGHTTS egprsWindowSizeEightTimeSlot
EGPLGPONETS egprsPollingPeriodOneTimeSlot
EGPLGPTWOTS egprsPollingPeriodTwoTimeSlot
EGPLGPTHREETS egprsPollingPeriodThreeTimeSlot
EGPLGPFOURTS egprsPollingPeriodFourTimeSlot
EGPLGPFIVETS egprsPollingPeriodFiveTimeSlot
EGPLGPSIXTS egprsPollingPeriodSixTimeSlot
EGPLGPSEVENTS egprsPollingPeriodSevenTimeSlot
EGPLGPEIGHTTS egprsPollingPeriodEightTimeSlot
PERSTLVPRI<n> persistenceLevelPriority<n>
NCC1TH ncC1Threshold
NCRARESH ncRaReselectHysteresis
NCSARA ncSameRoutingArea
NCTRFPSCTH ncTrafficPSControlThreshold
CRESELTRHINP cellReselectionThresholdInput
PKTMEASREPCNT packetMeasurementReportCounter
MSRMAXU mobileStationRateMaxUsed
FPER flowPercentage
PFCIBMAPER pFCInteractiveBucketMaxPercentage
PFCIBMAPPER pFCInteractiveBucketMaxPcuPercentage
PFCIBHIPER pFCInteractiveBucketHighPercentage
PFCIBLPER pFCInteractiveBucketLowPercentage
PFCBBMAPER pFCBackgroundBucketMaxPercentage
PFCBBMAPPER pFCBackgroundBucketMaxPcuPercentage
PFCBBHIPER pFCBackgroundBucketHighPercentage
PFCBBLPER pFCBackgroundBucketLowPercentage
PFCSBMAPER pFCStreamingBucketMaxPercentage
PFCSBMAPPER pFCStreamingBucketMaxPcuPercentage
PFCSBHIPER pFCStreamingBucketHighPercentage
PFCSBLPER pFCStreamingBucketLowPercentage


A30808-X3247-M230-6-7619

925
CML:BSC PTPPKF
Id:0900d805800d5658
PFCIRMAXU pFCInteractiveRateMaxUsed
PFCBRMAXU pFCBackgroundRateMaxUsed
PFCSRMAXU pFCStreamingRateMaxUsed
PFCIRPER pFCInteractiveRatePercentage
PFCBRPER pFCBackgroundRatePercentage
PFCSRPER pFCStreamingRatePercentage
TFAILNCU timerFailNcUmtsCell
MAFAILNCU maxFailNcUmtsCell
TBNCU timerBackNcUmts
EUMSSNCRESEL enableUmtsMssNcResel
CPCUN commonPCUNumber
BCGRWEI backgroundWeight
BEPFIDLWEI bestEffortPFIDLWeight
INTRTRFH1WEI interactiveTrafficHandlingPrio1Weight
INTRTRFH2WEI interactiveTrafficHandlingPrio2Weight
INTRTRFH3WEI interactiveTrafficHandlingPrio3Weight
SPFIWEI signallingPFIWeigh
SMSINFO smsInfo
STREAMWEI streamingWeight
EDASUP eDASupport
GFDDRSCPMI gprsFddRscpMin
GFDDQMIO gprsFddQMinOffset
EDTMSUP enableDTMSupport
LLCDVOLTRSH lLCDataVolumeThreshold
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The relevant BTS object instance must be already created.
At least one PCU instance must already exist in the related CPCU.
At least one NSVC, related to the same CPCU, must be created.
The related CPCU doesn't exist.


926 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
In order to have a PTPPKF under a CPCU, at least a PCU over IP
or an NSVC must be equipped under that CPCU.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The "ThresholdIdleChanHV" field of the GASTRTH attribute has to
be lower than the "ThresholdIdleChanVH" field.
The "ThresholdIdleChanVH" field of the GASTRTH attribute has to
be lower than or equal to the "ThresholdIdleChanEU" field.
UNSUCCESSFUL_INVALID_STATUS
The command must be done in LOCKED state if the following
attributes are changed: RACODE, RACOL, GPDPDTCHA,
EEDGE.
In order to set the CSCH3CSCH4SUP attribute the PTPPKF object
must be in LOCKED state.
In order to set the SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3,
SCHWEIPRI4 attributes the PTPPKF object must be in LOCKED
state.
INCOMP_NESWLOAD_VS_MESSAGE
The CSCH3CSCH4SUP cannot be set at TRUE if the
SW Version running on the superordinated BTSM belongs to BR6.0
release (see EXPSWV parameter description).
BEPAVGP, EGWSONETS...EGWSEIGHTS,
EGPLGPONETS...EGPLGPEIGHTS attributes can not be set at a
value different from NULL, if the SW Version running on the
superordinated BTSM object belongs to BR6.0 release (see
EXPSWV parameter description).
The attribute EBCCHTRX can not be set at TRUE if the SW Version
running on the superordinated BTSM object belongs to BR6.0
release (see EXPSWV parameter description).
The attribute EEDGE can not be set at TRUE if the SW Version
running on the superordinated BTSM object belongs to BR6.0
release (see EXPSWV parameter description).
BEPAVGP, EGWSONETS..EGWSEIGHTS,
EGPLGPONETS..EGPLGPEIGHTS can not be set at a value differ-
ent from NULL, if the BTSE is not of one of the following types: BS-
240, BS-240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR,
BS-40, BS-41.
BEPAVGP, EGWSONETS..EGWSEIGHTS,
EGPLGPONETS..EGPLGPEIGHTS can not be set at NULL value ,
if the BTSE is of one of the following types: BS-240, BS-240SR,
BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41.


A30808-X3247-M230-6-7619

927
CML:BSC PTPPKF
Id:0900d805800d5658
The attribute EBCCHTRX can not be set at TRUE if the BTSE is not
of one of the following types: BS-240, BS-240SR, BS-241,
BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41.
The attribute EEDGE can not be set at TRUE if the BTSE is not of
one of the following types: BS-240, BS-240SR, BS-241,
BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41.
The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK,
EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK,
EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL,
EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL,
EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK,
INIMCSDL can not be set at a value different from NULL if the SW
Version running on the superordinated BTSM object belongs to
BR6.0 release (see EXPSWV parameter description).
The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK,
EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK,
EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL,
EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL,
EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK,
INIMCSDL can not be set at a value different from NULL if the HW
Version of the BTSE is different from BTS+.
The following attributes: EMFA1UNIR8PSK, EMFAP1UNIR8PSK,
EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK,
EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL,
EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL,
EMCSFAMGDL, IMCSULNIR8PSK, IMCSULNIRGMSK,
INIMCSDL can not be set at NULL value if the HW Version of the
BTSE is BTS+.
If the SW Version running on the superordinated BTSM object (see
EXPSWV parameter description), the ELKADPT attribute must be
set to FALSE.
EDTMSUP can be enabled only for those BTSM that support DTM
feature.
UNSUCCESSFUL_CODING_SCHEME_NOT_SUPPORTED
In order to set CSCH3CSCH4SUP at TRUE, CSCH3CSCH4SUP in
BSC object must be TRUE.
The INICSCH attribute cannot be set at CS3 or CS4 if the
CSCH3CSCH4SUP attribute is set at FALSE and vice versa.
The INICSCH attribute cannot be set to a value greater than CS2 if
Bit 25 of MNTBMASK (SET BSC command) has been set to 1.
UNSUCCESSFUL_EDGE_NOT_SUPPORTED


928 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
In order to set the flag EEDGE to TRUE in PTPPKF object, every
layer assigned to the primary/complementary layer list of EDGE
service (ELLPRM and ELLCOM attributes of the BTS object) must
contain:
- at least one TRX with TRXMD=EDGE, if the layer is not exclusive
for EDGE
- all the TRXs with TRXMD=EDGE, if the layer is exclusive for
EDGE.
The attribute EBCCHTRX can not be set at TRUE if the related
BCCH TRX has TRXMD set at GSM or the ESUP attribute of BSC
object is set at FALSE.
UNSUCCESSFUL_GPRS_NOT_SUPPORTED
The flag EGPRS cannot be TRUE if both GLLPRM and GLLCOM
are set to NULL in the BTS object.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set. For more details
see Application Guideline n. 4.
In case of not extended cells the attributes EMANPRESCOM and
GMANPRESCOM must be 0.
The attribute EGPRS can not be set at FALSE if EEDGE is set at
TRUE.
The attribute EEDGE can not be set at TRUE if EGPRS is set at
FALSE.
The attribute EEDGE can not be set at TRUE if CSCH3CSCH4SUP
is set at FALSE
The following relations between the SCHWEIPRI1, SCHWEIPRI2,
SCHWEIPRI3, SCHWEIPRI4 attributes must be satisfied:
SCHWEIPRI1 >= SCHWEIPRI2 >= SCHWEIPRI3 >=
SCHWEIPRI4.
The BVCBHIPER attribute cannot be set at a value lower or equal
than BVCBLPER.
The MSBHIPER attribute cannot be set at a value lower or equal
than MSBLPER.
EGWSyTS value must be major or equal than EGWSxTS and minor
or equal than EGWSzTS, where x < y< z
The ELKADPT attribute cannot be set to TRUE if the NTWCARD
parameter (BSC object) is set to NTWSN16.
The NCTRFPSCTH attribute must be set to a value less than CRE-
SELTRHSOUT.
The NCTRFPSCTH attribute must be set to a value greater than
CRESELTRHINP.


A30808-X3247-M230-6-7619

929
CML:BSC PTPPKF
Id:0900d805800d5658
The STGTTLLINF attribute must be set to a value greater than TRF-
PSCTRLT. Note that as the range of the TRFPSCTRLT attribute (1-
100) is bigger than the range of the STGTTLLINF attribute (10-90)
the values greater than 90 of the TRFPSCTRLT attribute will no
more be accepted by the BSC.
No more than 20 different combinations of (MCC-MNC-LAC-
RACODE) are permitted inside BSC.
The BEPFIDLWEI value must be less or equal than the field pfi-
Weight of SMSINFO attribute.
The field pfiWeight of SMSINFO attribute must be less or equal than
SPFIWEI.
The BCGRWEI value must be less or equal than INTRTRFH3WEI.
The INTRTRFH3WEI value must be less or equal than
INTRTRFH2WEI.
The INTRTRFH2WEI value must be less or equal than
INTRTRFH1WEI
The INTRTRFH1WEI value must be less or equal than STREAM-
WEI.
The attribute EUMSSNCRESEL cannot be TRUE if the attribute
NCRESELFLAG is disabled.
The attribute EUMSSNCRESEL cannot be TRUE if the attribute
EUSCNCRESEL is disabled.
The PFCIBHIPER attribute cannot be set to a value lower or equal
than PFCIBLPER.
The PFCBBHIPER attribute cannot be set to a value lower or equal
than PFCBBLPER.
The PFCSBHIPER attribute cannot be set to a value lower or equal
than PFCSBLPER.
All PTPPKF with the same MCC, MNC, LAC and RACODE must be
served by the same CPCU.
EDTMSUP can be enabled only if at least one layer is shared
between signalling (signallingLayerList), circuit (circuitSwitched-
SpeechLayerList or aMRFullRateLayerList or aMRHalfRateLayer-
List) and packet (gprsLayerList or edgeLayerList) services.
EDTMSUP cannot be enabled in case of EXTENDED cells.
EDTMSUP cannot be enabled when EGPRS is FALSE.
EDTMSUP cannot be enabled when EARCLM is disabled.
UNSUCCESSFUL_WRONG_MCS
The IMCSULNIR8PSK chosen does not belong to the family
enabled for Uplink 8PSK without Incremental Redundancy, i.e
EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK,
EMFCUNIR8PSK, EMFGUNIR8PSK.


930 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
The IMCSULNIRGMSK chosen does not belong to the family
enabled for GSMK without Incremental Redundancy, i.e.
EMFCUNIRGMSK and EMFGUNIRGMSK.
The INIMCSDL chosen does not belong to the family enabled for
EMCSFAMA1DL, i.e. EMCSFAMAP1DL, EMCSFAMB1DL,
EMCSFAMCDL, EMCSFAMGDL.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
If the BCCH is involved in a BBHOP hopping law and the BCCH
TRX has TRXMD=EDGE, EBCCHTRX cannot be set at FALSE.
GPRS_TSC_INCONSISTENT
If the EGPRS flag is set at TRUE in the PTPPKF object the following
TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM, single TCHs on timeslot
from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM all single TCHs must have
the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
If the DTMSUP flag is set at TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area, single TCHs on timeslot from 1 to 7 must have the
same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area all single TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
GPRS_HOPP_INCONSISTENT


A30808-X3247-M230-6-7619

931
CML:BSC PTPPKF
Id:0900d805800d5658
If the EGPRS flag is set at TRUE in the PTPPKF object the following
TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM, single TCHs on timeslot
from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in GLLPRM/GLLCOM, different from the BCCH
one, all single TCHs must have the same FHSYD and MAIO.
If the DTMSUP flag is set at TRUE in the PTPPKF object the follow-
ing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area, single TCHs on timeslot from 1 to 7 must have the
same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to the
layers shared between Signalling, Circuit and Packet Services in
Primary area, different from the BCCH one, all single TCHs must
have the same FHSYD and MAIO.
EDGE_TSC_INCONSISTENT
If the EEDGE flag is set at TRUE in the PTPPKF object the following
TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, single TCHs on timeslot
from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, all single TCHs must have
the same TSC.
The command is rejected if some TSCs are set at the same value
and the others are skipped.
EDGE_HOPP_INCONSISTENT


932 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
Application Guidelines:
1. The value of BSPBBLK, BPAGCHR and BPRACHR parameters has to be set in
such a way to have at least one block of each of the following types:
PBCCH, PPCH, PAGCH for DL;
PRACH for UL.
For instance, if BSPBBLK is set at 1 the maximum value for BPAGCHR is 9.
2. The difference between the "ThresholdIdleChanVH" and "ThresholdIdleChanHV"
fields of GASTRTH parameter has to be set at a value not too much high, in order
to have a real hysteresis behaviour.
3. The following relationships must be verified:
NCTRFPSCTH < = CRESELTRHSOUT
NCTRFPSCTH > CRESELTRHINP
4. The maximum admitted value of the GMANPRES attribute is equal to 190. This
attribute is meaningful only for the first shared layer. When setting the value of this
attribute, the operator must pay attention about how many shared layers are
equipped, and how many timeslots he would like to reserve to GPRS/EGPRS ser-
vices, otherwise he could lose all circuit switched traffic.
5. When enabling CS-3 /CS-4 coding schemes, make sure that the bit25 of
MNTBMASK parameter is set to FALSE, otherwise (bit25 of MNTBMASK=TRUE)
the max coding scheme usable is forced to CS-2 independently from
CSCH3CSCH4SUP value set to TRUE.
With bit 25 of MNTBMASK set to 1, then the CSCH3CSCH4SUP attribute becomes
a flag for stating if CONCATENATED PCU frames or STANDARD PCU frames will
If the EEDGE flag is set at TRUE in the PTPPKF object the following
TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, single TCHs on timeslot
from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the MOBALLOC
of the FHSY object instance cannot contain the BCCH frequency
and all channels on the BCCH-TRX cannot hop (i.e. FHSYD
attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to the
layers contained in ELLPRM/ELLCOM, different from the BCCH
one, all single TCHs must have the same FHSYD and MAIO.


A30808-X3247-M230-6-7619

933
CML:BSC PTPPKF
Id:0900d805800d5658
be used in the whole PTPPKF, that is, on all the TRX supporting EGPRS or GPRS
of the related PTPPKF:
- when CSCH3CSCH4SUP is set to TRUE, CONCATENATED PCU frames are
used
- when CSCH3CSCH4SUP is set to FALSE, STANDARD PCU frames are used.
Therefore the check that to enable EDGE, CSCH3CSCH4SUP attribute has to be
set to TRUE, is kept.
This also means that in a PTPPKF having the following settings:
- bit 25 of MNTBMASK set to 1;
- CSCH3CSCH4SUP set to TRUE;
- EEDGE set to TRUE;
then the maximum GPRS coding scheme will be CS2 and CONCATENATED PCU
frames will be used on all the TRX supporting EGPRS or GPRS of the related
PTPPKF.
Again, in a PTPPKF having the following settings:
- bit 25 of MNTBMASK set to 1;
- CSCH3CSCH4SUP set to TRUE;
- EEDGE set to FALSE;
then the maximum GPRS coding scheme will be CS2 and CONCATENATED PCU
frames will be used on all the TRX supporting EGPRS or GPRS of the related
PTPPKF.
6. The value of BSPBBLK and BPAGCHR parameters has to be set in such way to
have at least one block of any type:
- PBCCH, PPCH, PAGCH for DL;
- PRACH and PDTCH/PACCH for UL.
For instance if BSPBBLK is set to 1 the maximum value for BPAGCHR is 9.
Example of Command Execution:
Create PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0,RACODE=1,
RACOL=5,BSCDVMA=5, PKTNDEC=6,PKTNINC=7,PKTNMA=0,GRXLAMI=10,
GMSTXPMAC=20,ABUTYP=0,RAARET=0,GPATH=2,GTXINT=9,GS=3,
GMANRETS=2, GMANMSAL=7-9,T3166_68=2,T3192=3,INICSCH=CS1,GCELL-
RESH=7,C31H=0,C31QUAL=TRUE, TRESEL=5,RARESH=6,GHCSTH=11,GHC-
SPC=4,
ALPHA=8,TAVGW=15,TAVGT=7, PRPBCCH=12,PCMECH=0,NAVGI=9,
BSPBBLK=0,BPAGCHR=5,PBRACHR=8, DRXTMA=4,CACKTYP=1,
GASTRTH=10-20-20,GPDPDTCHA=0,QSRHPRI=UMDB82,FDDGQO=DB08,
GMANPRESCOM=0, GMANPRESPRM=0, EMANPRESCOM=0, EMANPRESPRM=0,
TRFPSCTRLT=5, NTWCREPPIDL=MSEC480, NTWCREPPIDL=MSEC61440,
NTWCNDRXP=MSEC960, CRESELTRHSOUT=85, GUMTSSRHPRI=FALSE, GFD-
DQMI=MDB18, TDDGQO=DB16, GFDDREPQTY=RSCP, GNMULBAC=2, GFD-


934 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
DMURREP=1, GTDDMURREP=1, CSCH3CSCH4SUP=FALSE,
BVCBHIPER=70,BVCBSPPER=PER200,BVCBMAPER=PER100,
BVCBLPER=PER60, MSBSPPER=PER200, MSBHIPER=PER70, MSB-
MAPER=PER100,MSBLPER=PER60,ELKADPT=FALSE,
BLERAVEUL=UNIT400, BLERAVEDL=UNIT400, EMFA1UNIR8PSK=TRUE,
EMFAP1UNIR8PSK=FALSE, EMFB1UNIR8PSK=FALSE, EMFCUNIR8PSK=FALSE,
EMFGUNIR8PSK=FALSE, EMFCUNIRGMSK=FALSE, EMFGUNIR-
GMSK=TRUE,EMCSFAMA1DL=TRUE, EMCSFAMAP1DL=FALSE,
EMCSFAMB1DL=FALSE,EMCSFAMCDL=FALSE,
EMCSFAMGDL=FALSE,IMCSULNIR8PSK=MCS6,IMCSULNIRGMSK=MCS3,
INIMCSDL=MCS9,RAENV=HIGHDIV,STGTTLLIINF=60,INIBLER=PER20,
SCHWEIPRI1=7,SCHWEIPRI2=6,SCHWEIPRI3=5,SCHWEIPRI4=2,
EBCCHTRX=FALSE,EEDGE=TRUE,EGPRS=TRUE,BEPAVGP=5,
EGWSONETS=192,EGWSTWOTS=256,EGWSTHREETS=384,EGWSFOURTS=512,
EGWSFIVETS=640,EGWSSIXTS=768,EGWSSEVENTS=896,
EGWSEIGHTTS=1024,EGPLGPONETS=16,EGPLGPTWOTS=16,
EGPLGPTHREETS=16,EGPLGPFOURTS=16,EGPLGPFIVETS=16,
EGPLGPSIXTS=16,EGPLGPSEVENTS=16,EGPLGPEIGHTTS=16,
PERSTLVPRI1=5,PERSTLVPRI2=5,PERSTLVPRI3=5,PERSTLVPRI4=5,
NCC1TH=DB03,NCRARESH=DB00,NCSAMERA=TRUE, NCTRFPSCTH=75, CRE-
SELTRHINP=66, PKTMEASREPCNT, BEPFIDLWEI=1, SMSINFO=1-160, SPFI-
WEI=16, INTRTRFH1WEI=8, INTRTRFH2WEI=4, INTRTRFH3WEI=2, BCGRWEI=1,
STREAMWEI=32, TFAILNCU=5, MAFAILNCU=5, TBNCU=5, EUMSSNCRE-
SEL=FALSE, CPCUN=1, MSRMAXU=FALSE, FPER=15, PFCIBMAPER=100, PFCIB-
MAPPER=200, PFCIBHIPER=70, PFCIBLPER=60, PFCBBMAPER=100,
PFCBBMAPPER=200, PFCBBHIPER=70, PFCBBLPER=60, PFCSBMAPER=100,
PFCSBMAPPER=200, PFCSBHIPER=70, PFCSBLPER=60, PFCIRMAXU=FALSE,
PFCBRMAXU=FALSE, PFCSRMAXU=FALSE, PFCIRPER=100, PFCBRPER=100,
PFCSRPER=100, EDASUP=DISABLED, GFDDRSCPMI=MDB101, GFDDQ-
MIO=DB00, LLCDVOLTRSH=0; EDTMSUP=DISABLED, EEDGE=FALSE;
DELETE PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF DELETE
PTPPKF
Applicability:
Phase 2.
Visibility level: 2.
DELETE PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


A30808-X3247-M230-6-7619

935
CML:BSC PTPPKF
Id:0900d805800d5658
Command Description:
This command deletes a previously created instance of the PTPPKF object class. It can
be done only if the object is in Locked state. The appropriate system information shall
be sent on Um interface to inform the mobile about availability of the service. Because
of also SGSN knows the BVCI connected to this object, appropriate actions to inform it
about new PTPPKF configurations should be taken by BSC.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a PTPPKF, the relative object instance must be in
LOCKED state.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
A GPRS handover relationship (ADJC) can be configured only between
two GPRS cells (PTPPKF equipped).
This means that no incoming relationship must contain GSUP set at
TRUE; this parameter cannot be TRUE in any ADJC object in the BSC
referring the BTS with the same instance number of the PTPPKF being
deleted as TGTCELL.
The same nack cause is generated for the outgoing ADJC relationship:
GSUP cannot be TRUE in any ADJC instance subordinated to the BTS
with the same instance number of the PTPPKF being deleted.
The QSMONGPRS object instances associated to the PTPPKF object
instance must be previously deleted.
The PTPPKF object cannot be deleted if there at least one layer is asso-
ciated to the service layer list related to GPRS or EGPRS service.


936 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
GET PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GET
PTPPKF
GET PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0 [,REQATTL=
RACODE ,RACOL ,BSCDVMA ,PKTNDEC ,PKTNINC
,PKTNMA ,GRXLAMI ,GMSTXPMAC ,ABUTYP ,RAARET
,GPATH ,GTXINT ,GS ,GMANRETS ,GMANMSAL ,T3168
,T3192 ,INICSCH ,NTWCOR ,GCELLRESH ,C31H
,C32QUAL ,TRESEL ,RARESH ,GHCSTH ,GHCSPC
,ALPHA ,TAVGW ,TAVGT ,PRPBCCH ,PCMECH ,NAVGI
,BSPBBLK ,BPAGCHR ,BPRACHR ,DRXTMA ,CACKTYP
,GAM ,GASTRTH ,GPDPDTCHA ,QSRHPRI ,FDDGQO
,GMANPRESPRM ,GMANPRESCOM ,EMANPRESPRM
,EMANPRESCOM ,TRFPSCTRLT ,NTWCREPPTR
,NTWCREPPIDL ,NTWCNDRXP ,CRESELTRHSOUT
,GUMTSSRHPRI ,GFDDQMI ,TDDGQO ,GFDDREPQTY
,GNMULBAC ,GFDDMURREP ,GTDDMURREP
,CSCH3CSCH4SUP ,BVCBSPPER ,BVCBHIPER ,BVCB-
MAPER ,BVCBLPER ,MSBSPPER ,MSBHIPER ,MSB-
MAPER ,MSBLPER ,ELKADPT ,BLERAVEUL
,BLERAVEDL ,EMFA1UNIR8PSK ,EMFAP1UNIR8PSK
,EMFB1UNIR8PSK ,EMFCUNIR8PSK ,EMFGUNIR8PSK
,EMFCUNIRGMSK ,EMFGUNIRGMSK ,EMCSFAMA1DL
,EMCSFAMAP1DL ,EMCSFAMB1DL ,EMCSFAMCDL
,EMCSFAMGDL ,IMCSULNIR8PSK ,IMCSULNIRGMSK
,INIMCSDL ,RAENV ,STGTTLLIINF ,INIBLER
,SCHWEIPRI1 ,SCHWEIPRI2 ,SCHWEIPRI3
,SCHWEIPRI4 ,EBCCHTRX ,EEDGE ,EGPRS ,BEPAVGP
,EGWSONETS ,EGWSTWOTS ,EGWSTHREETS ,EGWS-
FOURTS ,EGWSFIVETS ,EGWSSIXTS ,EGWSSEVENTS
,EGWSEIGHTTS ,EGPLGPONETS ,EGPLGPTWOTS
,EGPLGPTHREETS ,EGPLGPFOURTS ,EGPLGPFIVETS
,EGPLGPSIXTS ,EGPLGPSEVENTS ,EGPLGPEIGHTTS
,PERSTLVPRI<n> ,NCC1TH ,NCRARESH ,NCSARA
,NCTRFPSCTH ,CRESELTRHINP ,PKTMEASREPCNT
,MSRMAXU ,FPER ,PFCIBMAPER ,PFCIBMAPPER
,PFCIBHIPER ,PFCIBLPER ,PFCBBMAPER ,PFCBBMAP-
PER ,PFCBBHIPER ,PFCBBLPER ,PFCSBMAPER
,PFCSBMAPPER ,PFCSBHIPER ,PFCSBLPER ,PFCIR-
MAXU ,PFCBRMAXU ,PFCSRMAXU ,PFCIRPER
,PFCBRPER ,PFCSRPER ,TFAILNCU ,MAFAILNCU
,TBNCU ,EUMSSNCRESEL ,CPCUN ,BCGRWEI ,BEP-
FIDLWEI ,INTRTRFH1WEI ,INTRTRFH2WEI
,INTRTRFH3WEI ,SPFIWEI ,SMSINFO ,STREAMWEI
,EDASUP ,GFDDRSCPMI ,GFDDQMIO ,EDTMSUP ,LLCD-
VOLTRSH];


A30808-X3247-M230-6-7619

937
CML:BSC PTPPKF
Id:0900d805800d5658
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PTPPKF
object class.
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
RACOL routingAreaColour
BSCDVMA bsCountdownValueMax
PKTNDEC packetNumberDecrement
PKTNINC packetNumberIncrement
PKTNMA packetNumberMax
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
ABUTYP accessBurstType
RAARET randomAccessRetry
GPATH gprsPriorityAccessThreshold
GTXINT gprsTxInterval
GS gprsSlot
GMANRETS gprsMaxNumberRetransmission
GMANMSAL gprsMaxNumberMsAllocated
T3168 t3168
T3192 t3192
INICSCH initialCodingScheme
NTWCOR networkControlOrder
GCELLRESH gprsCellReselectHysteresis
C31H c31Hysteresis
C32QUAL c32Qualifier
TRESEL timerReselection
RARESH routingAreaReselectHysteresis
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
ALPHA alpha
TAVGW tAverageWeight
TAVGT tAverageTime
PRPBCCH powerReductionOnPbcch
PCMECH powerControlMeasurementChannel


938 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
NAVGI nAverageInterference
BSPBBLK bsPbcchBlocks
BPAGCHR bsPagchBlocksReserved
BPRACHR bsPrachBlocksReserved
DRXTMA discontinousReceptionTimerMax
CACKTYP controlAcknowledgementType
GAM gamma
GASTRTH gprsAllocationStrategyThresholds
GPDPDTCHA gprsPercentageOfDynamicPdtchAvailable
QSRHPRI qSearchPriority
FDDGQO fddGPRSQOffset
GMANPRESPRM gprsMaxNumberPDCHResPrimary
GMANPRESCOM gprsMaxNumberPDCHResComplementary
EMANPRESPRM edgeMaxNumberPDCHResPrimary
EMANPRESCOM edgeMaxNumberPDCHResComplementary
TRFPSCTRLT trafficPSControlTimer
NTWCREPPTR networkControlReportPeriodTransfer
NTWCREPPIDL networkControlReportPeriodIdle
NTWCNDRXP networkControlNonDRXPeriod
CRESELTRHSOUT cellReselectionThresholdOutput
GUMTSSRHPRI gprsUmtsSearchPriority
GFDDQMI gprsFddQMin
TDDGQO tddGprsQOffset
GFDDREPQTY gprsFddReportingQuantity
GNMULBAC gprsNMultibandCell
GFDDMURREP gprsFddMultiratReporting
GTDDMURREP gprsTddMultiratReporting
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
BVCBSPPER bvcBucketSizePcuPercentage
BVCBHIPER bvcBucketHighPercentage
BVCBMAPER bvcBucketMaxPercentage
BVCBLPER bvcBucketLowPercentage
MSBSPPER msBucketSizePcuPercentage
MSBHIPER msBucketHighPercentage
MSBMAPER msBucketMaxPercentage
MSBLPER msBucketLowPercentage
ELKADPT enableLinkAdaptation
BLERAVEUL blockErrorRateAveragingPeriodUplink
BLERAVEDL blockErrorRateAveragingPeriodDownlink


A30808-X3247-M230-6-7619

939
CML:BSC PTPPKF
Id:0900d805800d5658
EMFA1UNIR8PSK enMcsFamAMcs1UplinkWoutIncrRed8Psk
EMFAP1UNIR8PSK enMcsFamApMcs1UplinkWoutIncrRed8Psk
EMFB1UNIR8PSK enMcsFamBMcs1UplinkWoutIncRed8Psk
EMFCUNIR8PSK enMcsFamCUplinkWoutIncRed8Psk
EMFGUNIR8PSK enMcsFamGmskUplinkWoutIncRed8Psk
EMFCUNIRGMSK enMcsFamCUplinkWoutIncrRedGmsk
EMFGUNIRGMSK enMcsFamGmskUplinkWoutIncrRedGmsk
EMCSFAMA1DL enMcsFamAMcs1Downlink
EMCSFAMAP1DL enMcsFamAPaddingMcs1Downlink
EMCSFAMB1DL enMcsFamBMcs1Downlink
EMCSFAMCDL enMcsFamCDownlink
EMCSFAMGDL enMcsFamGmskDownlink
IMCSULNIR8PSK initialMcsUplinkWoutIncrRed8psk
IMCSULNIRGMSK initialMcsUplinkWoutIncrRedGmsk
INIMCSDL initialMcsDownlink
RAENV radioEnvironment
STGTTLLIINF storageTimeTLLIInfo
INIBLER initialBLER
SCHWEIPRI1 schedulingWeightOfPriority1
SCHWEIPRI2 schedulingWeightOfPriority2
SCHWEIPRI3 schedulingWeightOfPriority3
SCHWEIPRI4 schedulingWeightOfPriority4
EBCCHTRX egprs8pskOnBcchTrx
EEDGE enableEdge
EGPRS enableGprs
BEPAVGP bitErrorProbabilityAveragePeriod
EGWSONETS egprsWindowSizeOneTimeSlot
EGWSTWOTS egprsWindowSizeTwoTimeSlot
EGWSTHREETS egprsWindowSizeThreeTimeSlot
EGWSFOURTS egprsWindowSizeFourTimeSlot
EGWSFIVETS egprsWindowSizeFiveTimeSlot
EGWSSIXTS egprsWindowSizeSixTimeSlot
EGWSSEVENTS egprsWindowSizeSevenTimeSlot
EGWSEIGHTTS egprsWindowSizeEightTimeSlot
EGPLGPONETS egprsPollingPeriodOneTimeSlot
EGPLGPTWOTS egprsPollingPeriodTwoTimeSlot
EGPLGPTHREETS egprsPollingPeriodThreeTimeSlot
EGPLGPFOURTS egprsPollingPeriodFourTimeSlot
EGPLGPFIVETS egprsPollingPeriodFiveTimeSlot


940 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
EGPLGPSIXTS egprsPollingPeriodSixTimeSlot
EGPLGPSEVENTS egprsPollingPeriodSevenTimeSlot
EGPLGPEIGHTTS egprsPollingPeriodEightTimeSlot
PERSTLVPRI<n> persistenceLevelPriority<n>
NCC1TH ncC1Threshold
NCRARESH ncRaReselectHysteresis
NCSARA ncSameRoutingArea
NCTRFPSCTH ncTrafficPSControlThreshold
CRESELTRHINP cellReselectionThresholdInput
PKTMEASREPCNT packetMeasurementReportCounter
MSRMAXU mobileStationRateMaxUsed
FPER flowPercentage
PFCIBMAPER pFCInteractiveBucketMaxPercentage
PFCIBMAPPER pFCInteractiveBucketMaxPcuPercentage
PFCIBHIPER pFCInteractiveBucketHighPercentage
PFCIBLPER pFCInteractiveBucketLowPercentage
PFCBBMAPER pFCBackgroundBucketMaxPercentage
PFCBBMAPPER pFCBackgroundBucketMaxPcuPercentage
PFCBBHIPER pFCBackgroundBucketHighPercentage
PFCBBLPER pFCBackgroundBucketLowPercentage
PFCSBMAPER pFCStreamingBucketMaxPercentage
PFCSBMAPPER pFCStreamingBucketMaxPcuPercentage
PFCSBHIPER pFCStreamingBucketHighPercentage
PFCSBLPER pFCStreamingBucketLowPercentage
PFCIRMAXU pFCInteractiveRateMaxUsed
PFCBRMAXU pFCBackgroundRateMaxUsed
PFCSRMAXU pFCStreamingRateMaxUsed
PFCIRPER pFCInteractiveRatePercentage
PFCBRPER pFCBackgroundRatePercentage
PFCSRPER pFCStreamingRatePercentage
TFAILNCU timerFailNcUmtsCell
MAFAILNCU maxFailNcUmtsCell
TBNCU timerBackNcUmts
EUMSSNCRESEL enableUmtsMssNcResel
CPCUN commonPCUNumber
BCGRWEI backgroundWeight
BEPFIDLWEI bestEffortPFIDLWeight
INTRTRFH1WEI interactiveTrafficHandlingPrio1Weight
INTRTRFH2WEI interactiveTrafficHandlingPrio2Weight


A30808-X3247-M230-6-7619

941
CML:BSC PTPPKF
Id:0900d805800d5658
INTRTRFH3WEI interactiveTrafficHandlingPrio3Weight
SPFIWEI signallingPFIWeigh
SMSINFO smsInfo
STREAMWEI streamingWeight
EDASUP eDASupport
GFDDRSCPMI gprsFddRscpMin
GFDDQMIO gprsFddQMinOffset
EDTMSUP enableDTMSupport
LLCDVOLTRSH lLCDataVolumeThreshold
System Responses:
- Operation Completed
NAME: name
RACODE: RoutingAreaCode
RACOL: RoutingAreaColour
BSCDVMA: bscountdownValueMax
PKTNDEC: packetNumberDecrement
PKTNINC: packetNumberIncrement
PKTNMA: packetNumberMax
GRXLAMI: gprsLevAccessMin
GMSTXPMAC: gprsMxTxPwrMaxCch
ABUTYP: accessBurstType
RAARET: randomAccessRetry
GPATH: gprsPriorityAccessThreshold
GTXINT: gprsTxInterval
GS: gprsSlot
GMANRETS: gprsMaxNumberRetransmission
GMANMSAL: gprsMaxNumberMsAllocated
T3168: t3168
T3192: t3192
INICSCH: initialCodingScheme
NTWCOR: networKControlOrder
GCELLRESH: gprsCellReselectHysteresis
C31H: c31Hysteresis
C32QUAL: c32Qualifier
TRESEL: tResel
RARESH: routingAreaReselectHysteresis


942 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
GHCSTH: gprsHierarchycalCellStructureThreshold
GHCSPC: gprsHierarchycalCellStructurePriorityClass
ALPHA: alphaPowerControlAlgorithm
TAVGW: tAverageWeight
TAVGT: AverageTime
PRPBCCH: powerRedactionOnPbcch
PCMECH: oowerControlMeasurementChannel
NAVGI: nAverageInterference
BSPBBLK bsPbcchBlocks
BPAGCHR: bsPagchBlocksReserved
BPRACHR: bsPrachBlocksReserved
DRXTXMA: discontinousReceptionTimerMax
CACKTYP: controlAcknowledgementType
GAM: gamma
GASTRTH: gprsAllocationStrategyThresholds
GPDPDTCHA: gprsPercentageOfDinamicPdtchAvailable
QSRHPRI: qSearchPriority
FDDGQO: fddGPRSQOffset
GMANPRESCOM: gprsMaxNumberPDCHResComplementary
GMANPRESPRM: gprsMaxNumberPDCHResPrimary
EMANPRESCOM: edgeMaxNumberPDCHResComplementary
EMANPRESPRM: edgeMaxNumberPDCHResPrimary
TRFPSCTRLT TrafficPSControlTimer
NTWCREPPTR: NetworkControlReportPeriodTransfer
NTWCREPPIDL: networkControlReportPeriodIdle
NTWCNDRXP: networkControlNonDRXPeriod
CRESELTRHSOUT: cellReselectionThresholdOutput
GUMTSSRHPRI: gprsUmtsSearchPriority
GFDDQMI: GprsFddQmin
TDDGQO: tddGprsQOffset
GFDDREPQTY: GprsFddReportingQuantity
GNMULBAC: gprsNMultibandCell
GFDDMURREP gprsFddMultiratReporting
GTDDMURREP gprsTddMultiratReporting
CSCH3CSCH4SUP: codingScheme3CodingScheme4Support
BVCBHIPER: bvcBucketHighPercentage


A30808-X3247-M230-6-7619

943
CML:BSC PTPPKF
Id:0900d805800d5658
BVCBSPPER: bvcBucketSizePcuPercentage
BVCBMAPER: bvcBucketMaxPercentage
BVCBLPER: bvcBucketLowPercentage
MSBSPPER: msBucketSizePcuPercentage
MSBHIPER: msBucketHighPercentage
MSBMAPER: msBucketMaxPercentage
MSBLPER: msBucketLowPercentage
ELKADPT: enableLinkAdaptation
BLERAVEUL: blockErrorRateAveragingPeriodUplink
BLERAVEDL: blockErrorRateAveragingPeriodDownlink
EMFA1UNIR8PSK: enMcsFamAMcs1UplinkWoutIncrRed8Psk
EMFAP1UNIR8PSK
:
enMcsFamApMcs1UplinkWoutIncrRed8Psk
EMFB1UNIR8PSK: enMcsFamBMcs1UplinkWoutIncRed8Psk
EMFCUNIR8PSK: enMcsFamCUplinkWoutIncRed8Psk
EMFGUNIR8PSK: enMcsFamGmskUplinkWoutIncRed8Psk
EMFCUNIRGMSK: enMcsFamCUplinkWoutIncrRedGmsk
EMFGUNIRGMSK: enMcsFamGmskUplinkWoutIncrRedGmsk
EMCSFAMA1DL: enMcsFamAMcs1Downlink
EMCSFAMAP1DL: enMcsFamAPaddingMcs1Downlink
EMCSFAMB1DL: enMcsFamBMcs1Downlink
EMCSFAMCDL: enMcsFamCDownlink
EMCSFAMGDL: enMcsFamGmskDownlink
IMCSULNIR8PSK: initialMcsUplinkWoutIncrRed8psk
IMCSULNIRGMSK: initialMcsUplinkWoutIncrRedGmsk
INIMCSDL: initialMcsDownlink
RAENV: radioEnvironment
STGTTLLIINF: storageTimeTLLIInfo
INIBLER: initialBLER
SCHWEIPRI1: schedulingWeightOfPriority1
SCHWEIPRI2: schedulingWeightOfPriority2
SCHWEIPRI3: schedulingWeightOfPriority3
SCHWEIPRI4: schedulingWeightOfPriority4
EBCCHTRX: egprs8pskOnBcchTrx
EEDGE: enableEdge
EGPRS: enableGprs
BEPAVGP: bitErrorProbabilityAveragePeriod


944 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
EGWSONETS: egprsWindowSizeOneTimeSlot
EGWSTWOTS: egprsWindowSizeTwoTimeSlot
EGWSTHREETS: egprsWindowSizeThreeTimeSlot
EGWSFOURTS: egprsWindowSizeFourTimeSlot
EGWSFIVETS: egprsWindowSizeFiveTimeSlot
EGWSSIXTS: egprsWindowSizeSixTimeSlot
EGWSSEVENTS: egprsWindowSizeSevenTimeSlot
EGWSEIGHTTS: egprsWindowSizeEightTimeSlot
EGPLGPONETS: egprsPollingPeriodOneTimeSlot
EGPLGPTWOTS: egprsPollingPeriodTwoTimeSlot
EGPLGPTHREETS: egprsPollingPeriodThreeTimeSlot
EGPLGPFOURTS: egprsWindowSizeFourTimeSlot
EGPLGPFIVETS: egprsPollingPeriodFiveTimeSlot
EGPLGPSIXTS: egprsPollingPeriodSixTimeSlot
EGPLGPSEVENTS: egprsPollingPeriodSevenTimeSlot
EGPLGPEIGHTTS: egprsPollingPeriodEightTimeSlot
PERSTLVPRI1: persistenceLevelPriority1
PERSTLVPRI2: persistenceLevelPriority2
PERSTLVPRI3: persistenceLevelPriority3
PERSTLVPRI4: persistenceLevelPriority4
NCC1TH: NcC1Threshold
NCRARESH: NcRaReselectHysteresis
NCSAMERA: NcSameRoutingArea
NCTRFPSCTH: ncTrafficPSControlThreshold
CRESELTRHINP: cellReselectionThresholdInput
PKTMEAS-
REPCNT:
packetMeasurementReportCounter
BEPFIDLWEI: bestEffortPFIDLWeight
SMSINFO: smsInfo
SPFIWEI: signallingPFIWeight
INTRTRFH1WEI: interactiveTrafficHandlingPriority1Weight
INTRTRFH2WEI: interactiveTrafficHandlingPriority2Weight
INTRTRFH3WEI: interactiveTrafficHandlingPriority3Weight
BCGRWEI: backgroundWeight
STREAMWEI: streamingWeight
TFAILNCU: timerFailNcUmtsCell
MFAILNCU: maxFailNcUmtsCell


A30808-X3247-M230-6-7619

945
CML:BSC PTPPKF
Id:0900d805800d5658
GET PTPPKF BASICS
TBNCU: timerBackNcUmts
EUMSSNCRESEL: enableUmtsMssNcResel
CPCUN: commonPCUNumber
MSRMAXU: MobileStationRateMaxUsed
FPER: FlowPercentage
PFCIBMAPER: PFCInteractiveBucketMaxPercentage
PFCIBMAPPER: PFCInteractiveBucketMaxPcuPercentage)
PFCIBHIPER: PFCInteractiveBucketHighPercentage
PFCIBLPER: PFCInteractiveBucketLowPercentage
PFCBBMAPER: PFCBackgroundBucketMaxPercentage
PFCBBMAPPER: PFCBackgroundBucketMaxPcuPercentage
PFCBBHIPER: PFCBackgroundBucketHighPercentage
PFCBBLPER: PFCBackgroundBucketLowPercentage
PFCSBMAPER: PFCStreamingBucketMaxPercentage
PFCSBMAPER: PFCStreamingBucketMaxPercentage
PFCSBMAPPER: PFCStreamingBucketMaxPcuPercentage
PFCSBHIPER: PFCStreamingBucketHighPercentage
PFCSBLPER: PFCStreamingBucketLowPercentage
PFCIRMAXU: PFCInteractiveRateMaxUsed
PFCBRMAXU: PFCBackgroundRateMaxUsed
PFCSRMAXU: PFCStreamingRateMaxUsed
PFCIRPER: PFCInteractiveRatePercentage
PFCSRPER: PFCStreamingRatePercentage
PFCBRPER: PFCBackgroundRatePercentage
EDASUP: eDASupport
GFDDRSCPMI: gprsFddRscpMin
GFDDQMIO: gprsFddQminOffset
LLCDVOLTRSH: ILCDataVolumeThreshold
NAME: name
RACODE: RoutingAreaCode
RACOL: RoutingAreaColour
BSCDVMA: bscountdownValueMax
PKTNDEC: packetNumberDecrement
PKTNINC: packetNumberIncrement


946 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
PKTNMA: packetNumberMax
GRXLAMI: gprsLevAccessMin
GMSTXPMAC: gprsMxTxPwrMaxCch
ABUTYP: accessBurstType
RAARET: randomAccessRetry
GPATH: gprsPriorityAccessThreshold
GTXINT: gprsTxInterval
GS: gprsSlot
GMANRETS: gprsMaxNumberRetransmission
GMANMSAL: gprsMaxNumberMsAllocated
T3168: t3168
T3192: t3192
INICSCH: initialCodingScheme
NTWCOR: networKControlOrder
GCELLRESH: gprsCellReselectHysteresis
C31H: c31Hysteresis
C32QUAL: c32Qualifier
TRESEL: tResel
RARESH: routingAreaReselectHysteresis
GHCSTH: gprsHierarchycalCellStructureThreshold
GHCSPC: gprsHierarchycalCellStructurePriorityClass
ALPHA: alphaPowerControlAlgorithm
TAVGW: tAverageWeight
TAVGT: AverageTime
PRPBCCH: powerRedactionOnPbcch
PCMECH: oowerControlMeasurementChannel
NAVGI: nAverageInterference
BSPBBLK: bsPbcchBlocks
BPAGCHR: bsPagchBlocksReserved
BPRACHR: bsPrachBlocksReserved
DRXTXMA: discontinousReceptionTimerMax
CACKTYP: controlAcknowledgementType
GAM: gamma
GASTRTH: gprsAllocationStrategyThresholds
GPDPDTCHA: gprsPercentageOfDinamicPdtchAvailable
QSRHPRI: qSearchPriority


A30808-X3247-M230-6-7619

947
CML:BSC PTPPKF
Id:0900d805800d5658
FDDGQO: fddGPRSQOffset
GMANPRESCOM: gprsMaxNumberPDCHResComplementary
GMANPRESPRM: gprsMaxNumberPDCHResPrimary
EMANPRESCOM: edgeMaxNumberPDCHResComplementary
EMANPRESPRM: edgeMaxNumberPDCHResPrimary
TRFPSCTRLT: TrafficPSControlTimer
NTWCREPPR: NetworkControlReportPeriodTransfer
NTWCREPPIDL: networkControlReportPeriodIdle
NTWCNDRXP: networkControlNonDRXPeriod
CRE-
SELTRHSOUT:
cellReselectionThresholdOutput
GUMTSSRHPRI: gprsUmtsSearchPriority
GFDDQMI: GprsFddQmin
TDDGQO: tddGprsQOffset
GFDDREPQTY: GprsFddReportingQuantity
GNMULBAC: gprsNMultibandCell
GFDDMURREP gprsFddMultiratReporting
GTDDMURREP gprsTddMultiratReporting
CSCH3CSCH4SUP
:
codingScheme3CodingScheme4Support
BVCBHIPER: bvcBucketHighPercentage
BVCBSPPER: bvcBucketSizePcuPercentage
BVCBMAPER: bvcBucketMaxPercentage
BVCBLPER: bvcBucketLowPercentage
MSBSPPER: msBucketSizePcuPercentage
MSBHIPER: msBucketHighPercentage
MSBMAPER: msBucketMaxPercentage
MSBLPER: msBucketLowPercentage
ELKADPT: enableLinkAdaptation
BLERAVEUL: blockErrorRateAveragingPeriodUplink
BLERAVEDL: blockErrorRateAveragingPeriodDownlink
EMFA1UNIR8PSK: enMcsFamAMcs1UplinkWoutIncrRed8Psk
EMFAP1UNIR8PSK
:
enMcsFamApMcs1UplinkWoutIncrRed8Psk
EMFB1UNIR8PSK: enMcsFamBMcs1UplinkWoutIncRed8Psk
EMFCUNIR8PSK: enMcsFamCUplinkWoutIncRed8Psk
EMFGUNIR8PSK: enMcsFamGmskUplinkWoutIncRed8Psk


948 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
EMFCUNIRGMSK: enMcsFamCUplinkWoutIncrRedGmsk
EMFGUNIRGMSK: enMcsFamGmskUplinkWoutIncrRedGmsk
EMCSFAMA1DL: enMcsFamAMcs1Downlink
EMCSFAMAP1DL: enMcsFamAPaddingMcs1Downlink
EMCSFAMB1DL: enMcsFamBMcs1Downlink
EMCSFAMCDL: enMcsFamCDownlink
EMCSFAMGDL: enMcsFamGmskDownlink
IMCSULNIR8PSK: initialMcsUplinkWoutIncrRed8psk
IMCSULNIRGMSK: initialMcsUplinkWoutIncrRedGmsk
INIMCSDL: initialMcsDownlink
RAENV: radioEnvironment
STGTTLLIINF: storageTimeTLLIInfo
INIBLER: initialBLER
SCHWEIPRI1: schedulingWeightOfPriority1
SCHWEIPRI2: schedulingWeightOfPriority2
SCHWEIPRI3: schedulingWeightOfPriority3
SCHWEIPRI4: schedulingWeightOfPriority4
EBCCHTRX: egprs8pskOnBcchTrx
EEDGE: enableEdge
EGPRS: enableGprs
BEPAVGP: bitErrorProbabilityAveragePeriod
EGWSONETS: egprsWindowSizeOneTimeSlot
EGWSTWOTS: egprsWindowSizeTwoTimeSlot
EGWSTHREETS: egprsWindowSizeThreeTimeSlot
EGWSFOURTS: egprsWindowSizeFourTimeSlot
EGWSFIVETS: egprsWindowSizeFiveTimeSlot
EGWSSIXTS: egprsWindowSizeSixTimeSlot
EGWSSEVENTS: egprsWindowSizeSevenTimeSlot
EGWSEIGHTTS: egprsWindowSizeEightTimeSlot
EGPLGPONETS: egprsPollingPeriodOneTimeSlot
EGPLGPTWOTS: egprsPollingPeriodTwoTimeSlot
EGPLGPTHREETS
:
egprsPollingPeriodThreeTimeSlot
EGPLGPFOURTS: egprsWindowSizeFourTimeSlot
EGPLGPFIVETS: egprsPollingPeriodFiveTimeSlot
EGPLGPSIXTS: egprsPollingPeriodSixTimeSlot


A30808-X3247-M230-6-7619

949
CML:BSC PTPPKF
Id:0900d805800d5658
EGPLGPSEV-
ENTS:
egprsPollingPeriodSevenTimeSlot
EGPLGPEIGHTTS: egprsPollingPeriodEightTimeSlot
PERSTLVPRI1: persistenceLevelPriority1
PERSTLVPRI2: persistenceLevelPriority2
PERSTLVPRI3: persistenceLevelPriority3
PERSTLVPRI4: persistenceLevelPriority4
NCC1TH: NcC1Threshold
NCRARESH: NcRaReselectHysteresis
NCSAMERA: NcSameRoutingArea
NCTRFPSCTH: ncTrafficPSControlThreshold
CRESELTRHINP: cellReselectionThresholdInput
PKTMEAS-
REPCNT:
packetMeasurementReportCounter
BEPFIDLWEI: bestEffortPFIDLWeight
SMSINFO: smsInfo
SPFIWEI: signallingPFIWeight
INTRTRFH1WEI: interactiveTrafficHandlingPriority1Weight
INTRTRFH2WEI: interactiveTrafficHandlingPriority2Weight
INTRTRFH3WEI: interactiveTrafficHandlingPriority3Weight
BCGRWEI: backgroundWeight
STREAMWEI: streamingWeight
CPCUN: commonPCUNumber
TFAILNCU: timerFailNcUmtsCell
MFAILNCU: maxFailNcUmtsCell
TBNCU: timerBackNcUmts
EUMSSNCRESEL: enableUmtsMssNcResel
MSRMAXU: MobileStationRateMaxUsed
FPER: FlowPercentage
PFCIBMAPER: PFCInteractiveBucketMaxPercentage
PFCIBMAPPER: PFCInteractiveBucketMaxPcuPercentage)
PFCIBHIPER: PFCInteractiveBucketHighPercentage
PFCIBLPER: PFCInteractiveBucketLowPercentage
PFCBBMAPER: PFCBackgroundBucketMaxPercentage
PFCBBMAPPER: PFCBackgroundBucketMaxPcuPercentage
PFCBBHIPER: PFCBackgroundBucketHighPercentage
PFCBBLPER: PFCBackgroundBucketLowPercentage


950 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET PTPPKF BASICS
None.
Example of Command Execution:
Get PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0,REQATTL=RACODE&
RACOL&BSCDVMA&PKTNDEC&PKTNINC&PKTNMA&GRXLAMI&GMSTXPMAC&
ABUTYP&RAARET&GPATH&GTXINT&GS&GMANRETS&GMANMSAL&
T3168&T3192&INICSCH&NTWCOR&GCELLRESH&C31H&C32QUAL&
TRESEL&RARESH&GHCSTH&GHCSPC& ALPHA&TAVGW&TAVGT&PRPB-
CCH&PCMECH&NAVGI&BSPBBLK&BPAGCHR&
BPRACHR&DRXTMA&CACKTYP&GAM&GASTRTH&GPDPDTCHA&QSRHPRI&
FDDGQO&GMANPRESCOM&GMANPRESPRM&EMANPRESCOM&EMANPRE-
SPRM&TRFPSCTRLT&NTWCREPPTR&NTWCREPPIDL&NTWCNDRXP&CRE-
SELTRHSOUT&GUMTSSRHPRI&GFDDQMI&TDDGQO&GFDDREPQTY&GNMULB
PFCSBMAPER: PFCStreamingBucketMaxPercentage
PFCSBMAPER: PFCStreamingBucketMaxPercentage
PFCSBMAPPER: PFCStreamingBucketMaxPcuPercentage
PFCSBHIPER: PFCStreamingBucketHighPercentage
PFCSBLPER: PFCStreamingBucketLowPercentage
PFCIRMAXU: PFCInteractiveRateMaxUsed
PFCBRMAXU: PFCBackgroundRateMaxUsed
PFCSRMAXU: PFCStreamingRateMaxUsed
PFCIRPER: PFCInteractiveRatePercentage
PFCSRPER: PFCStreamingRatePercentage
PFCBRPER: PFCBackgroundRatePercentage
EDASUP: eDASupport
GFDDRSCPMI: gprsFddRscpMin
GFDDQMIO: gprsFddQminOffset
LLCDVOLTRSH: ILCDataVolumeThreshold
EDTMSUP: enableDTMSupport
EEDGE: enableEdge
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

951
CML:BSC PTPPKF
Id:0900d805800d5658
AC&GFDDMURREP& GTDDMURREP&CSCH3CSCH4SUP&BVCBHIPER&BVCBSP-
PER&BVCBMAPER&BVCBLPER&MSBSPPER&MSBHIPER
&MSBMAPER&MSBLPER&ELKADPT&BLERAVEUL&BLERAVEDL&
EMFA1UNIR8PSK&EMFAP1UNIR8PSK&EMFB1UNIR8PSK&EMFCUNIR8PSK&
EMFGUNIR8PSK&EMFCUNIRGMSK&EMFGUNIRGMSK&EMCSFAMA1DL&
EMCSFAMAP1DL&EMCSFAMB1DL&EMCSFAMCDL&EMCSFAMGDL
&IMCSULNIR8PSK&IMCSULNIRGMSK&INIMCSDL&RAENV&STGTTLLI-
INF&INIBLER&SCHWEIPRI1&SCHWEIPRI2&SCHWEIPRI3&SCHWEIPRI4&
EBCCHTRX&EEDGE&EGPRS&BEPAVGP&EGWSONETS&
EGWSTWOTS&EGWSTHREETS&EGWSFOURTS&
EGWSFIVETS&EGWSSIXTS&EGWSSEVENTS&EGWSEIGHTTS&
EGPLGPONETS&EGPLGPTWOTS&EGPLGPTHREETS&EGPLGPFOURTS&
EGPLGPFIVETS&EGPLGPSIXTS&EGPLGPSEVENTS&EGPLGPEIGHTTS&
PERSTLVPRI1&PERSTLVPRI2&PERSTLVPRI3&PERSTLVPRI4&NCC1TH&NCRAR
ESH&NCSAMERA&NCTRFPSCTH&CRESELTRHINP&PKTMEASREPCNT&BEP-
FIDLWEI&SMSINFO&SPFI-
WEI&INTRTRFH1WEI&INTRTRFH2WEI&INTRTRFH3WEI&BCGRWEI&TFAILNCU&
MFAILNCU&TBNCU&EUMSSNCRESEL&CPCUN&MSRMAXU&FPER&PFCIB-
MAPER&PFCIBMAPPER&PFCIB-
HIPER&PFCIBLPER&PFCBBMAPER&PFCBBMAPPER&PFCBBHIPER&PFCBBLPE
R&PFCSBMAPER&PFCSBMAPPER&PFCSBHIPER&PFCSBLPER&PFCIRMAXU&
PFCBRMAXU&PFCSRMAXU&PFCIRPER&PFCBRPER&PFCSRPER&EDA-
SUP&GFDDRSCPMI&GFDDQMIO&LLCDVOLTRSH& EDTMSUP& EEDGE;
GET PTPPKF BASICS
Get PTPPKF BASICS:NAME=BTSM:0/BTS:0/PTPPKF:0;
GET PTPPKF BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GET
PTPPKF BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the PTPPKF
object class.
Long Names:
NAME Addres of the managed object
GET PTPPKF BASICS NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


952 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
RACODE routingAreaCode
RACOL routingAreaColour
BSCDVMA bsCountdownValueMax
PKTNDEC packetNumberDecrement
PKTNINC packetNumberIncrement
PKTNMA packetNumberMax
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
ABUTYP accessBurstType
RAARET randomAccessRetry
GPATH gprsPriorityAccessThreshold
GTXINT gprsTxInterval
GS gprsSlot
GMANRETS gprsMaxNumberRetransmission
GMANMSAL gprsMaxNumberMsAllocated
T3168 t3168
T3192 t3192
INICSCH initialCodingScheme
NTWCOR networkControlOrder
GCELLRESH gprsCellReselectHysteresis
C31H c31Hysteresis
C32QUAL c32Qualifier
TRESEL timerReselection
RARESH routingAreaReselectHysteresis
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
ALPHA alpha
TAVGW tAverageWeight
TAVGT tAverageTime
PRPBCCH powerReductionOnPbcch
PCMECH powerControlMeasurementChannel
NAVGI nAverageInterference
BSPBBLK bsPbcchBlocks
BPAGCHR bsPagchBlocksReserved
BPRACHR bsPrachBlocksReserved
DRXTMA discontinousReceptionTimerMax
CACKTYP controlAcknowledgementType
GAM gamma
GASTRTH gprsAllocationStrategyThresholds


A30808-X3247-M230-6-7619

953
CML:BSC PTPPKF
Id:0900d805800d5658
GPDPDTCHA gprsPercentageOfDynamicPdtchAvailable
QSRHPRI qSearchPriority
FDDGQO fddGPRSQOffset
GMANPRESPRM gprsMaxNumberPDCHResPrimary
GMANPRESCOM gprsMaxNumberPDCHResComplementary
EMANPRESPRM edgeMaxNumberPDCHResPrimary
EMANPRESCOM edgeMaxNumberPDCHResComplementary
TRFPSCTRLT trafficPSControlTimer
NTWCREPPTR networkControlReportPeriodTransfer
NTWCREPPIDL networkControlReportPeriodIdle
NTWCNDRXP networkControlNonDRXPeriod
CRESELTRHSOUT cellReselectionThresholdOutput
GUMTSSRHPRI gprsUmtsSearchPriority
GFDDQMI gprsFddQMin
TDDGQO tddGprsQOffset
GFDDREPQTY gprsFddReportingQuantity
GNMULBAC gprsNMultibandCell
GFDDMURREP gprsFddMultiratReporting
GTDDMURREP gprsTddMultiratReporting
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
BVCBSPPER bvcBucketSizePcuPercentage
BVCBHIPER bvcBucketHighPercentage
BVCBMAPER bvcBucketMaxPercentage
BVCBLPER bvcBucketLowPercentage
MSBSPPER msBucketSizePcuPercentage
MSBHIPER msBucketHighPercentage
MSBMAPER msBucketMaxPercentage
MSBLPER msBucketLowPercentage
ELKADPT enableLinkAdaptation
BLERAVEUL blockErrorRateAveragingPeriodUplink
BLERAVEDL blockErrorRateAveragingPeriodDownlink
EMFA1UNIR8PSK enMcsFamAMcs1UplinkWoutIncrRed8Psk
EMFAP1UNIR8PSK enMcsFamApMcs1UplinkWoutIncrRed8Psk
EMFB1UNIR8PSK enMcsFamBMcs1UplinkWoutIncRed8Psk
EMFCUNIR8PSK enMcsFamCUplinkWoutIncRed8Psk
EMFGUNIR8PSK enMcsFamGmskUplinkWoutIncRed8Psk
EMFCUNIRGMSK enMcsFamCUplinkWoutIncrRedGmsk
EMFGUNIRGMSK enMcsFamGmskUplinkWoutIncrRedGmsk
EMCSFAMA1DL enMcsFamAMcs1Downlink


954 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
EMCSFAMAP1DL enMcsFamAPaddingMcs1Downlink
EMCSFAMB1DL enMcsFamBMcs1Downlink
EMCSFAMCDL enMcsFamCDownlink
EMCSFAMGDL enMcsFamGmskDownlink
IMCSULNIR8PSK initialMcsUplinkWoutIncrRed8psk
IMCSULNIRGMSK initialMcsUplinkWoutIncrRedGmsk
INIMCSDL initialMcsDownlink
RAENV radioEnvironment
STGTTLLIINF storageTimeTLLIInfo
INIBLER initialBLER
SCHWEIPRI1 schedulingWeightOfPriority1
SCHWEIPRI2 schedulingWeightOfPriority2
SCHWEIPRI3 schedulingWeightOfPriority3
SCHWEIPRI4 schedulingWeightOfPriority4
EBCCHTRX egprs8pskOnBcchTrx
EEDGE enableEdge
EGPRS enableGprs
BEPAVGP bitErrorProbabilityAveragePeriod
EGWSONETS egprsWindowSizeOneTimeSlot
EGWSTWOTS egprsWindowSizeTwoTimeSlot
EGWSTHREETS egprsWindowSizeThreeTimeSlot
EGWSFOURTS egprsWindowSizeFourTimeSlot
EGWSFIVETS egprsWindowSizeFiveTimeSlot
EGWSSIXTS egprsWindowSizeSixTimeSlot
EGWSSEVENTS egprsWindowSizeSevenTimeSlot
EGWSEIGHTTS egprsWindowSizeEightTimeSlot
EGPLGPONETS egprsPollingPeriodOneTimeSlot
EGPLGPTWOTS egprsPollingPeriodTwoTimeSlot
EGPLGPTHREETS egprsPollingPeriodThreeTimeSlot
EGPLGPFOURTS egprsPollingPeriodFourTimeSlot
EGPLGPFIVETS egprsPollingPeriodFiveTimeSlot
EGPLGPSIXTS egprsPollingPeriodSixTimeSlot
EGPLGPSEVENTS egprsPollingPeriodSevenTimeSlot
EGPLGPEIGHTTS egprsPollingPeriodEightTimeSlot
PERSTLVPRI<n> persistenceLevelPriority<n>
NCC1TH ncC1Threshold
NCRARESH ncRaReselectHysteresis
NCSARA ncSameRoutingArea
NCTRFPSCTH ncTrafficPSControlThreshold


A30808-X3247-M230-6-7619

955
CML:BSC PTPPKF
Id:0900d805800d5658
CRESELTRHINP cellReselectionThresholdInput
PKTMEASREPCNT packetMeasurementReportCounter
MSRMAXU mobileStationRateMaxUsed
FPER flowPercentage
PFCIBMAPER pFCInteractiveBucketMaxPercentage
PFCIBMAPPER pFCInteractiveBucketMaxPcuPercentage
PFCIBHIPER pFCInteractiveBucketHighPercentage
PFCIBLPER pFCInteractiveBucketLowPercentage
PFCBBMAPER pFCBackgroundBucketMaxPercentage
PFCBBMAPPER pFCBackgroundBucketMaxPcuPercentage
PFCBBHIPER pFCBackgroundBucketHighPercentage
PFCBBLPER pFCBackgroundBucketLowPercentage
PFCSBMAPER pFCStreamingBucketMaxPercentage
PFCSBMAPPER pFCStreamingBucketMaxPcuPercentage
PFCSBHIPER pFCStreamingBucketHighPercentage
PFCSBLPER pFCStreamingBucketLowPercentage
PFCIRMAXU pFCInteractiveRateMaxUsed
PFCBRMAXU pFCBackgroundRateMaxUsed
PFCSRMAXU pFCStreamingRateMaxUsed
PFCIRPER pFCInteractiveRatePercentage
PFCBRPER pFCBackgroundRatePercentage
PFCSRPER pFCStreamingRatePercentage
TFAILNCU timerFailNcUmtsCell
MAFAILNCU maxFailNcUmtsCell
TBNCU timerBackNcUmts
EUMSSNCRESEL enableUmtsMssNcResel
CPCUN commonPCUNumber
BCGRWEI backgroundWeight
BEPFIDLWEI bestEffortPFIDLWeight
INTRTRFH1WEI interactiveTrafficHandlingPrio1Weight
INTRTRFH2WEI interactiveTrafficHandlingPrio2Weight
INTRTRFH3WEI interactiveTrafficHandlingPrio3Weight
SPFIWEI signallingPFIWeigh
SMSINFO smsInfo
STREAMWEI streamingWeight
EDASUP eDASupport
GFDDRSCPMI gprsFddRscpMin
GFDDQMIO gprsFddQMinOffset
EDTMSUP enableDTMSupport


956 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
LLCDVOLTRSH lLCDataVolumeThreshold
System Responses:
See GET PTPPKF
Application Guidelines:
See GET PTPPKF
Example of Command Execution:
See GET PTPPKF
GET PTPPKF STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GET
PTPPKF STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PTPPKF object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
GET PTPPKF STAT NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

957
CML:BSC PTPPKF
Id:0900d805800d5658
Application Guidelines:
None.
Example of Command Execution:
Get PTPPKF STAT:NAME=BTSM:0/BTS:0/PTPPKF:0;
GETINFO PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GETINFO
PTPPKF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and statuses of the PTPPKF: AST, OST, AVS, PRS.
2. The BVCI number.
3. The PCU serving number.
4. The GPRS enable flag.
5. The bit map to know what TRX is enabled to support GPRS.
6. The EDGE enable flag.
7. The bit map to know what TRX is enabled to support EDGE.
8. The number of mobile in packed mode.
9. The mean data flow load percentage.
10. The peak of the data flow load percentage.
11. The mean connected mobiles number in the last 5 minutes.
12. The peak of the connected mobiles number in the last 5 minutes.
13. The Cell Global Identifier.
14. The Routing Area (RA) code.
15. The cumulative TRX availability for GPRS primary and complementary.
16. The cumulative TRX available for EDGE primary and complementary.
17. The GB SubNetwork Service (GBSNS) whose values are FRFIX or IPV4.
18. For each PDT the following information:
GETINFO PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


958 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
the PDT number;
the UST;
the TRX number;
the CHAN number;
the CHAN type;
19. If the value of GBSNS is FRFIX, it is displayed the list of NSVC; for each NSVC the
following information:
the NSVC instance number;
The AST;
The OST;
The AVS;
20. If the value of GBSNS is IPV4, it is displayed the list of NSVCIP; for each NSVCIP
the following information:
the NSVCIP instance number;
the OST;
the AVS;
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT PTPPKF: <BSS ID> <BTSM ID> <PTPPKF NR>
11:41:14 22/03/2001
Layout PTPPKF with FRFIX configuration
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PROCEDURAL STATUS: NONE
BVCI (PTPPKF ABSOLUTE NR +2): 3
PCU NR: 11
GPRS AVAILABLE: TRUE
GPRS ENABLE: TRUE
GPRS TRX MAP: 1 7 20 23
EDGE ENABLE : TRUE
EDGE TRX MAP : 2 5


A30808-X3247-M230-6-7619

959
CML:BSC PTPPKF
Id:0900d805800d5658
MOBILE NR. IN PACKED MODE: 10
MEAN DATA FLOW LOAD: 30%
PEAK DATA FLOW LOAD: 60%
MEAN CONNECTED MOBILES NUMBER (LAST 5 MIN): 2
PEAK CONNECTED MOBILES NUMBER (LAST 5 MIN): 7
CELL GLOBAL ID: 123 54 765 334
RA CODE: 24
CUMULATIVE TRX AVAIL GPRS PRIMARY: GSM
CUMULATIVE TRX AVAIL GPRS COMPLEMENTARY: EDGE
CUMULATIVE TRX AVAIL EGPRS PRIMARY: GSM
CUMULATIVE TRX AVAIL EGPRS COMPLEMENTARY: NONE
GB SUBNETWORK SERVICE: FRFIX
PDT NR USAGE TRX NR CHAN NR CHAN TYPE
0 BUSY 0 5 PCCCH
1 ACTIVE 1 2 PBCCH
399 BUSY 0 4 PCCH
NSVC NR. ADMINISTRATIVE OPERATIONAL AVAILABILITY (Max 16 values)
0 UNLOCKED ENABLED NONE
1 LOCKED ENABLED NONE
2 UNLOCKED DISABLED OFF_LINE
3 UNLOCKED ENABLED NONE
62 UNLOCKED ENABLED NONE
END OF REPORT
Layout PTPPKF with IPV4 configuration
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED


960 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PROCEDURAL STATUS: NONE
BVCI (PTPPKF ABSOLUTE NR +2): 3
PCU NR: 11
GPRS AVAILABLE: TRUE
GPRS ENABLE: TRUE
GPRS TRX MAP: 1 7 20 23
EDGE ENABLE : TRUE
EDGE TRX MAP : 2 5
MOBILE NR. IN PACKED MODE: 10
MEAN DATA FLOW LOAD: 30%
PEAK DATA FLOW LOAD: 60%
MEAN CONNECTED MOBILES NUMBER (LAST 5 MIN): 2
PEAK CONNECTED MOBILES NUMBER (LAST 5 MIN): 7
CELL GLOBAL ID: 123 54 765 334
RA CODE: 24
CUMULATIVE TRX AVAIL GPRS PRIMARY: GSM
CUMULATIVE TRX AVAIL GPRS COMPLEMENTARY: EDGE
CUMULATIVE TRX AVAIL EGPRS PRIMARY: GSM
CUMULATIVE TRX AVAIL EGPRS COMPLEMENTARY: NONE
GB SUBNETWORK SERVICE: IPV4
PDT NR USAGE TRX NR CHAN NR CHAN TYPE
1 BUSY 0 5 PCCCH
2 ACTIVE 1 2 PBCCH
399 BUSY 0 4 PCCH
NSVCIP NR OPERATIONAL AVAILABILITY
0 ENABLED NONE
1 ENABLED NONE
2 DISABLED DEPENDENCY
3 DISABLED FAILED


A30808-X3247-M230-6-7619

961
CML:BSC PTPPKF
Id:0900d805800d5658
255 ENABLED NONE
END OF REPORT
- Operation Failed
GETINFO PTPPKF NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack PTPPKF:
name = PTPPKF:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0;
GETRELATIONSHIP PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GETRELA-
TIONSHIP PTPPKF
Applicability:
Phase 2.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
PTPPKF
NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


962 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the PTPPKF object the related HMOs are the following: LICD/LICDS, EPWR, PPLD,
PWRD, MPCC, TDPC, MEMT, NTW, PPXL, PPXU and all the BTSE HMOs that imple-
ment the TRX functionality for a certain BTS. In case of GB-IP also the ES HMO is
handled.
For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR,
GPSU, LI, PA, RXMUCO, RXAMOD and TPU.
For BS-4x/240/241/240XL, the BTSE HMOs are: COBA, COSA, CU, DIDCTMA, DILNA,
DUDCTMA, DULNA, DUVSWR, FTNFP, FVSWRP and TMA.
For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0;
GETSUBO PTPPKF
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object does not provide any relationship attribute.
GETSUBO PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


A30808-X3247-M230-6-7619

963
CML:BSC PTPPKF
Id:0900d805800d5658
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF GETSUBO
PTPPKF
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of three subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0;
LOCK PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF LOCK
PTPPKF
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
The information about status of the cell must be notified to MSs via appropriate system
information and to SGSN via block procedure.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


964 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

965
CML:BSC PTPPKF
Id:0900d805800d5658
SET PTPPKF
SET PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0 [,RACODE=]
[,RACOL=] [,BSCDVMA=] [,PKTNDEC=] [,PKTNINC=]
[,PKTNMA=] [,GRXLAMI=] [,GMSTXPMAC=] [,ABUTYP=]
[,RAARET=] [,GPATH=] [,GTXINT=] [,GS=] [,GMANRETS=]
[,GMANMSAL=] [,T3168=] [,T3192=] [,INICSCH=] [,GCELL-
RESH=] [,C31H=] [,C32QUAL=] [,TRESEL=] [,RARESH=]
[,GHCSTH=] [,GHCSPC=] [,ALPHA=] [,TAVGW=]
[,TAVGT=] [,PRPBCCH=] [,PCMECH=] [,NAVGI=] [,BSPB-
BLK=] [,BPAGCHR=] [,BPRACHR=] [,DRXTMA=] [,CACK-
TYP=] [,GAM=] [,GASTRTH=] [,GPDPDTCHA=]
[,QSRHPRI=] [,FDDGQO=] [,GMANPRESPRM=] [,GMAN-
PRESCOM=] [,EMANPRESPRM=] [,EMANPRESCOM=]
[,TRFPSCTRLT=] [,NTWCREPPTR=] [,NTWCREPPIDL=]
[,NTWCNDRXP=] [,CRESELTRHSOUT=] [,GUMTSS-
RHPRI=] [,GFDDQMI=] [,TDDGQO=] [,GFDDREPQTY=]
[,GNMULBAC=] [,GFDDMURREP=] [,GTDDMURREP=]
[,CSCH3CSCH4SUP=] [,BVCBSPPER=] [,BVCBHIPER=]
[,BVCBMAPER=] [,BVCBLPER=] [,MSBSPPER=] [,MSB-
HIPER=] [,MSBMAPER=] [,MSBLPER=] [,ELKADPT=]
[,BLERAVEUL=] [,BLERAVEDL=] [,EMFA1UNIR8PSK=]
[,EMFAP1UNIR8PSK=] [,EMFB1UNIR8PSK=]
[,EMFCUNIR8PSK=] [,EMFGUNIR8PSK=] [,EMFCUNIR-
GMSK=] [,EMFGUNIRGMSK=] [,EMCSFAMA1DL=]
[,EMCSFAMAP1DL=] [,EMCSFAMB1DL=] [,EMCSFAM-
CDL=] [,EMCSFAMGDL=] [,IMCSULNIR8PSK=] [,IMC-
SULNIRGMSK=] [,INIMCSDL=] [,RAENV=]
[,STGTTLLIINF=] [,INIBLER=] [,SCHWEIPRI1=]
[,SCHWEIPRI2=] [,SCHWEIPRI3=] [,SCHWEIPRI4=] [,EBC-
CHTRX=] [,EEDGE=] [,EGPRS=] [,BEPAVGP=] [,EGWSO-
NETS=] [,EGWSTWOTS=] [,EGWSTHREETS=]
[,EGWSFOURTS=] [,EGWSFIVETS=] [,EGWSSIXTS=]
[,EGWSSEVENTS=] [,EGWSEIGHTTS=] [,EGPLGPO-
NETS=] [,EGPLGPTWOTS=] [,EGPLGPTHREETS=]
[,EGPLGPFOURTS=] [,EGPLGPFIVETS=]
[,EGPLGPSIXTS=] [,EGPLGPSEVENTS=] [,EGPLG-
PEIGHTTS=] [,PERSTLVPRI<n>=] [,NCC1TH=]
[,NCRARESH=] [,NCSARA=] [,NCTRFPSCTH=] [,CRE-
SELTRHINP=] [,PKTMEASREPCNT=] [,MSRMAXU=]
[,FPER=] [,PFCIBMAPER=] [,PFCIBMAPPER=] [,PFCIB-
HIPER=] [,PFCIBLPER=] [,PFCBBMAPER=] [,PFCBBMAP-
PER=] [,PFCBBHIPER=] [,PFCBBLPER=]


966 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF SET
PTPPKF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the PTPPKF object class. It is used
to change the configuration attributes associated to this object. Some attributes can be
changed without the interruption of the service while some other needs interruption of
the service. The following attributes can be changed only after PTPPKF locking, that
means service interruption: RACODE, RACOL and CACKTYP (reserved for further
implementation).
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
RACOL routingAreaColour
BSCDVMA bsCountdownValueMax
PKTNDEC packetNumberDecrement
PKTNINC packetNumberIncrement
PKTNMA packetNumberMax
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
ABUTYP accessBurstType
RAARET randomAccessRetry
GPATH gprsPriorityAccessThreshold
GTXINT gprsTxInterval
GS gprsSlot
GMANRETS gprsMaxNumberRetransmission
GMANMSAL gprsMaxNumberMsAllocated
T3168 t3168
T3192 t3192
SET PTPPKF [,PFCSBMAPER=] [,PFCSBMAPPER=] [,PFCSBHIPER=]
[,PFCSBLPER=] [,PFCIRMAXU=] [,PFCBRMAXU=] [,PFC-
SRMAXU=] [,PFCIRPER=] [,PFCBRPER=] [,PFCSRPER=]
[,TFAILNCU=] [,MAFAILNCU=] [,TBNCU=] [,EUMSSNCRE-
SEL=] [,CPCUN=] [,BCGRWEI=] [,BEPFIDLWEI=]
[,INTRTRFH1WEI=] [,INTRTRFH2WEI=]
[,INTRTRFH3WEI=] [,SPFIWEI=] [,SMSINFO=] [,STREAM-
WEI=] [,EDASUP=] [,GFDDRSCPMI=] [,GFDDQMIO=]
[,EDTMSUP=] [,LLCDVOLTRSH=];


A30808-X3247-M230-6-7619

967
CML:BSC PTPPKF
Id:0900d805800d5658
INICSCH initialCodingScheme
GCELLRESH gprsCellReselectHysteresis
C31H c31Hysteresis
C32QUAL c32Qualifier
TRESEL timerReselection
RARESH routingAreaReselectHysteresis
GHCSTH gprsHierarchicalCellStructureThreshold
GHCSPC gprsHierarchicalCellStructPriorityClass
ALPHA alpha
TAVGW tAverageWeight
TAVGT tAverageTime
PRPBCCH powerReductionOnPbcch
PCMECH powerControlMeasurementChannel
NAVGI nAverageInterference
BSPBBLK bsPbcchBlocks
BPAGCHR bsPagchBlocksReserved
BPRACHR bsPrachBlocksReserved
DRXTMA discontinousReceptionTimerMax
CACKTYP controlAcknowledgementType
GAM gamma
GASTRTH gprsAllocationStrategyThresholds
GPDPDTCHA gprsPercentageOfDynamicPdtchAvailable
QSRHPRI qSearchPriority
FDDGQO fddGPRSQOffset
GMANPRESPRM gprsMaxNumberPDCHResPrimary
GMANPRESCOM gprsMaxNumberPDCHResComplementary
EMANPRESPRM edgeMaxNumberPDCHResPrimary
EMANPRESCOM edgeMaxNumberPDCHResComplementary
TRFPSCTRLT trafficPSControlTimer
NTWCREPPTR networkControlReportPeriodTransfer
NTWCREPPIDL networkControlReportPeriodIdle
NTWCNDRXP networkControlNonDRXPeriod
CRESELTRHSOUT cellReselectionThresholdOutput
GUMTSSRHPRI gprsUmtsSearchPriority
GFDDQMI gprsFddQMin
TDDGQO tddGprsQOffset
GFDDREPQTY gprsFddReportingQuantity
GNMULBAC gprsNMultibandCell
GFDDMURREP gprsFddMultiratReporting


968 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
GTDDMURREP gprsTddMultiratReporting
CSCH3CSCH4SUP codingScheme3CodingScheme4Support
BVCBSPPER bvcBucketSizePcuPercentage
BVCBHIPER bvcBucketHighPercentage
BVCBMAPER bvcBucketMaxPercentage
BVCBLPER bvcBucketLowPercentage
MSBSPPER msBucketSizePcuPercentage
MSBHIPER msBucketHighPercentage
MSBMAPER msBucketMaxPercentage
MSBLPER msBucketLowPercentage
ELKADPT enableLinkAdaptation
BLERAVEUL blockErrorRateAveragingPeriodUplink
BLERAVEDL blockErrorRateAveragingPeriodDownlink
EMFA1UNIR8PSK enMcsFamAMcs1UplinkWoutIncrRed8Psk
EMFAP1UNIR8PSK enMcsFamApMcs1UplinkWoutIncrRed8Psk
EMFB1UNIR8PSK enMcsFamBMcs1UplinkWoutIncRed8Psk
EMFCUNIR8PSK enMcsFamCUplinkWoutIncRed8Psk
EMFGUNIR8PSK enMcsFamGmskUplinkWoutIncRed8Psk
EMFCUNIRGMSK enMcsFamCUplinkWoutIncrRedGmsk
EMFGUNIRGMSK enMcsFamGmskUplinkWoutIncrRedGmsk
EMCSFAMA1DL enMcsFamAMcs1Downlink
EMCSFAMAP1DL enMcsFamAPaddingMcs1Downlink
EMCSFAMB1DL enMcsFamBMcs1Downlink
EMCSFAMCDL enMcsFamCDownlink
EMCSFAMGDL enMcsFamGmskDownlink
IMCSULNIR8PSK initialMcsUplinkWoutIncrRed8psk
IMCSULNIRGMSK initialMcsUplinkWoutIncrRedGmsk
INIMCSDL initialMcsDownlink
RAENV radioEnvironment
STGTTLLIINF storageTimeTLLIInfo
INIBLER initialBLER
SCHWEIPRI1 schedulingWeightOfPriority1
SCHWEIPRI2 schedulingWeightOfPriority2
SCHWEIPRI3 schedulingWeightOfPriority3
SCHWEIPRI4 schedulingWeightOfPriority4
EBCCHTRX egprs8pskOnBcchTrx
EEDGE enableEdge
EGPRS enableGprs
BEPAVGP bitErrorProbabilityAveragePeriod


A30808-X3247-M230-6-7619

969
CML:BSC PTPPKF
Id:0900d805800d5658
EGWSONETS egprsWindowSizeOneTimeSlot
EGWSTWOTS egprsWindowSizeTwoTimeSlot
EGWSTHREETS egprsWindowSizeThreeTimeSlot
EGWSFOURTS egprsWindowSizeFourTimeSlot
EGWSFIVETS egprsWindowSizeFiveTimeSlot
EGWSSIXTS egprsWindowSizeSixTimeSlot
EGWSSEVENTS egprsWindowSizeSevenTimeSlot
EGWSEIGHTTS egprsWindowSizeEightTimeSlot
EGPLGPONETS egprsPollingPeriodOneTimeSlot
EGPLGPTWOTS egprsPollingPeriodTwoTimeSlot
EGPLGPTHREETS egprsPollingPeriodThreeTimeSlot
EGPLGPFOURTS egprsPollingPeriodFourTimeSlot
EGPLGPFIVETS egprsPollingPeriodFiveTimeSlot
EGPLGPSIXTS egprsPollingPeriodSixTimeSlot
EGPLGPSEVENTS egprsPollingPeriodSevenTimeSlot
EGPLGPEIGHTTS egprsPollingPeriodEightTimeSlot
PERSTLVPRI<n> persistenceLevelPriority<n>
NCC1TH ncC1Threshold
NCRARESH ncRaReselectHysteresis
NCSARA ncSameRoutingArea
NCTRFPSCTH ncTrafficPSControlThreshold
CRESELTRHINP cellReselectionThresholdInput
PKTMEASREPCNT packetMeasurementReportCounter
MSRMAXU mobileStationRateMaxUsed
FPER flowPercentage
PFCIBMAPER pFCInteractiveBucketMaxPercentage
PFCIBMAPPER pFCInteractiveBucketMaxPcuPercentage
PFCIBHIPER pFCInteractiveBucketHighPercentage
PFCIBLPER pFCInteractiveBucketLowPercentage
PFCBBMAPER pFCBackgroundBucketMaxPercentage
PFCBBMAPPER pFCBackgroundBucketMaxPcuPercentage
PFCBBHIPER pFCBackgroundBucketHighPercentage
PFCBBLPER pFCBackgroundBucketLowPercentage
PFCSBMAPER pFCStreamingBucketMaxPercentage
PFCSBMAPPER pFCStreamingBucketMaxPcuPercentage
PFCSBHIPER pFCStreamingBucketHighPercentage
PFCSBLPER pFCStreamingBucketLowPercentage
PFCIRMAXU pFCInteractiveRateMaxUsed
PFCBRMAXU pFCBackgroundRateMaxUsed


970 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
PFCSRMAXU pFCStreamingRateMaxUsed
PFCIRPER pFCInteractiveRatePercentage
PFCBRPER pFCBackgroundRatePercentage
PFCSRPER pFCStreamingRatePercentage
TFAILNCU timerFailNcUmtsCell
MAFAILNCU maxFailNcUmtsCell
TBNCU timerBackNcUmts
EUMSSNCRESEL enableUmtsMssNcResel
CPCUN commonPCUNumber
BCGRWEI backgroundWeight
BEPFIDLWEI bestEffortPFIDLWeight
INTRTRFH1WEI interactiveTrafficHandlingPrio1Weight
INTRTRFH2WEI interactiveTrafficHandlingPrio2Weight
INTRTRFH3WEI interactiveTrafficHandlingPrio3Weight
SPFIWEI signallingPFIWeigh
SMSINFO smsInfo
STREAMWEI streamingWeight
EDASUP eDASupport
GFDDRSCPMI gprsFddRscpMin
GFDDQMIO gprsFddQMinOffset
EDTMSUP enableDTMSupport
LLCDVOLTRSH lLCDataVolumeThreshold
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The pointed CPCU is not equipped..
There are no equipped PCUs in the related CPCU.
In order to modify the cpcun value, at least one NSVC, related
to the CPCU must be already created.
In order to have a PTPPKF under a CPCU, at least a PCU over
IP or an NSVC must be equipped under that CPCU.
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

971
CML:BSC PTPPKF
Id:0900d805800d5658
The command must be done in LOCKED state if the following
attributes are changed: RACODE, RACOL, GPDPDTCHA.
In order to set the CSCH3CSCH4SUP attribute the PTPPKF
object must be in LOCKED state.
The attribute EBCCHTRX can be modified only if the related
PTPPKF object is in LOCKED state.
The attribute EEDGE can be modified only if the related
PTPPKF object is in LOCKED state.
The following attributes can be changed only if the PTPPKF
object is in LOCKED state: ELKADPT, BLERAVEDL,
BLERAVEUL, EMFA1UNIR8PSK, EMFAP1UNIR8PSK,
EMFB1UNIR8PSK, EMFCUNIR8PSK, EMFGUNIR8PSK,
EMFCUNIRGMSK, EMFGUNIRGMSK, EMCSFAMA1DL,
EMCSFAMAP1DL, EMCSFAMB1DL, EMCSFAMCDL,
EMCSFAMGDL, RAENV.
In order to set the SCHWEIPRI1, SCHWEIPRI2, SCHWEIPRI3,
SCHWEIPRI4 attributes the PTPPKF object must be in
LOCKED state.
In order to set the BVCBSPER, BVCBHIPER, BVCBMAPER,
BVCBLPER, MSBSPER, MSBHIPER, MSBMAPER,
MSBLPER attributes the PTPPKF object must be in LOCKED
state.
In order to set the PFCIBMAPER, PFCIBMAPPER, PFCIB-
HIPER, PFCIBLPER, PFCBBMAPER, PFCBBMAPPER,
PFCBBHIPER, PFCBBLPER, PFCSBMAPER, PFCSBMAP-
PER, PFCSBHIPER and PFCSBLPER attributes the PTPPKF
must be locked.
In order to modify the cpcun value, the PTPPKF must be locked.
The attribute EDASUP cannot be changed if the PTPPKF is not
in LOCKED state.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The "ThresholdIdleChanHV" field of the GASTRTH attribute
has to be lower than the "ThresholdIdleChanVH" field.
The "ThresholdIdleChanVH" field of the GASTRTH attribute
has to be lower than or equal to the "ThresholdIdleChanEU"
field.
INCOMP_NESWLOAD_VS_MESSAGE
The CSCH3CSCH4SUP cannot be set at TRUE if the
SW Version running on the superordinated BTSM belongs to
BR6.0 release (see EXPSWV parameter description).


972 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
BEPAVGP, EGWSONETS, EGWSEIGHTS, EGPLGPONETS,
EGPLGPEIGHTS can not be set at a value different from NULL,
if the SW Version running on the superordinated BTSM object
belongs to BR6.0 release (see EXPSWV parameter descrip-
tion).
The attribute EBCCHTRX can not be set at TRUE if the SW
Version running on the superordinated BTSM object belongs to
BR6.0 release (see EXPSWV parameter description).
The attribute EEDGE can not be set at TRUE if the SW Version
running on the superordinated BTSM object belongs to BR6.0
release (see EXPSWV parameter description).
BEPAVGP, EGWSONETS, EGWSEIGHTS, EGPLGPONETS,
EGPLGPEIGHTS can not be set at a value different from NULL,
if the BTSE is not of one of the following types: BS-240, BS-
240SR, BS-241, BS-241SR, BS-240XL, BS-240XLSR, BS-40,
BS-41.
BEPAVGP, EGWSONETS, EGWSEIGHTS, EGPLGPONETS,
EGPLGPEIGHTS can not be set at NULL value, if the BTSE is
of one of the following types: BS-240, BS-240SR, BS-241,
BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41.
The attribute EBCCHTRX can not be set at TRUE if the BTSE
is not of one of the following types: BS-240, BS-240SR, BS-241,
BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41.
The attribute EEDGE can not be set at TRUE if the BTSE is not
of one of the following types: BS-240, BS-240SR, BS-241,
BS-241SR, BS-240XL, BS-240XLSR, BS-40, BS-41.
The following attributes: EMFA1UNIR8PSK,
EMFAP1UNIR8PSK, EMFB1UNIR8PSK,
EMFCUNIR8PSK, EMFGUNIR8PSK, EMFCUNIRGMSK,
EMFGUNIRGMSK, EMCSFAMA1DL, EMCSFAMAP1DL,
EMCSFAMB1DL, EMCSFAMCDL, EMCSFAMGDL,
IMCSULNIR8PSK, IMCSULNIRGMSK, INIMCSDL
can not be set at a value different from NULL if the SW Version
running on the superordinated BTSM object belongs to BR6.0
release (see EXPSWV parameter description).


A30808-X3247-M230-6-7619

973
CML:BSC PTPPKF
Id:0900d805800d5658
The following attributes: EMFA1UNIR8PSK,
EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK,
EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK,
EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL,
EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK,
IMCSULNIRGMSK, INIMCSDL can not be set at a value differ-
ent from NULL if the HW Version of the BTSE is different from
BTS+.
The following attributes: EMFA1UNIR8PSK,
EMFAP1UNIR8PSK, EMFB1UNIR8PSK, EMFCUNIR8PSK,
EMFGUNIR8PSK, EMFCUNIRGMSK, EMFGUNIRGMSK,
EMCSFAMA1DL, EMCSFAMAP1DL, EMCSFAMB1DL,
EMCSFAMCDL, EMCSFAMGDL, IMCSULNIR8PSK,
IMCSULNIRGMSK, INIMCSDL can not be set at NULL value if
the HW Version of the BTSE is BTS+.
If the SW Version running on the superordinated BTSM object
(see EXPSWV parameter description), the ELKADPT attribute
must be set to FALSE.
UNSUCCESSFUL_CODING_SCHEME_NOT_SUPPORTED
In order to set CSCH3CSCH4SUP at TRUE,
CSCH3CSCH4SUP in BSC object must be TRUE.
The INICSCH attribute cannot be set at CS3 or CS4 if the
CSCH3CSCH4SUP attribute is set at FALSE and vice versa.
The INICSCH attribute cannot be set to a value greater than
CS2 if BIT25 of MNTBMASK has been set to 1.
UNSUCCESSFUL_EDGE_NOT_SUPPORTED
In order to set the flag EEDGE to TRUE in PTPPKF object,
every layer assigned to the primary/complementary layer list of
EDGE service (ELLPRM and ELLCOM attributes of the BTS
object) must contain:
- at least one TRX with TRXMD=EDGE, if the layer is not exclu-
sive for EDGE
- all the TRXs with TRXMD=EDGE, if the layer is exclusive for
EDGE
The attribute EBCCHTRX can not be set at TRUE if the related
BCCH TRX has TRXMD set at GSM or the ESUP attribute of
BSC object is set at FALSE.
UNSUCCESSFUL_GPRS_NOT_SUPPORTED
The flag EGPRS cannot be TRUE if both GLLPRM and
GLLCOM attributes are set at NULL in the BTS object.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set. For more
details see Application Guideline n. 4.


974 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
In case of not extended cells the attributes EMANPRESCOM
and GMANPRESCOM must be 0.
The attribute EGPRS can not be set at FALSE if EEDGE is set
at TRUE.
The attribute EEDGE can not be set at TRUE if EGPRS is set
at FALSE.
The attribute EEDGE can not be set at TRUE if
CSCH3CSCH4SUP is set at FALSE.
The following relations between the SCHWEIPRI1,
SCHWEIPRI2, SCHWEIPRI3, SCHWEIPRI4 attributes must be
satisfied: SCHWEIPRI1 >= SCHWEIPRI2 >= SCHWEIPRI3 >=
SCHWEIPRI4.
The BVCBHIPER attribute cannot be set at a value lower or
equal than BVCBLPER.
The MSBHIPER attribute cannot be set at a value lower or
equal than MSBLPER.
EGWSyTS value must be major or equal than EGWSxTS and
minor or equal than EGWSzTS, where x < y< z
The ELKADPT attribute cannot be set to TRUE if the
NTWCARD parameter (BSC object) is set to NTWSN16.
The STGTTLLINF attribute must be set to a value greater than
TRFPSCTRLT. Note that as the range of the TRFPSCTRLT
attribute (1-100) is bigger than the range of the STGTTLLINF
attribute (10-90) the values greater than 90 of the TRFPSC-
TRLT attribute will no more be accepted by the BSC.
The NCTRFPSCTH attribute must be set to a value less than
CRESELTRHSOUT.
The NCTRFPSCTH attribute must be set to a value greater or
equal than CRESELTRHINP.
No more than 20 different combinations of (MCC-MNC-LAC-
RACODE) are permitted inside BSC.
The BEPFIDLWEI value must be less or equal than the field pfi-
Weight of SMSINFO attribute.
The field pfiWeight of SMSINFO attribute must be less or equal
than SPFIWEI.
The BCGRWEI value must be less or equal than
INTRTRFH3WEI.
The INTRTRFH3WEI value must be less or equal than
INTRTRFH2WEI.
The INTRTRFH2WEI value must be less or equal than
INTRTRFH1WEI
The INTRTRFH1WEI value must be less or equal than
STREAMWEI.


A30808-X3247-M230-6-7619

975
CML:BSC PTPPKF
Id:0900d805800d5658
The attribute EUMSSNCRESEL cannot be TRUE if the attribute
NCRESELFLAG is disabled.
The attribute EUMSSNCRESEL cannot be TRUE if the attribute
EUSCNCRESEL is disabled.
The PFCBBHIPER attribute cannot be set to a value lower or
equal than PFCBBLPER.
The PFCIBHIPER attribute cannot be set to a value lower or
equal than PFCIBLPER.
The PFCSBHIPER attribute cannot be set to a value lower or
equal than PFCSBLPER.
All PTPPKF with the same MCC, MNC, LAC and RACODE
must be served by the same CPCU.
UNSUCCESSFUL_WRONG_MCS
The IMCSULNIR8PSK chosen does not belong to the family
enabled for Uplink 8PSK without Incremental Redundancy, i.e
EMFA1UNIR8PSK, EMFAP1UNIR8PSK, EMFB1UNIR8PSK,
EMFCUNIR8PSK, EMFGUNIR8PSK.
The IMCSULNIRGMSK chosen does not belong to the family
enabled for GSMK without Incremental Redundancy, i.e.
EMFCUNIRGMSK and EMFGUNIRGMSK.
The INIMCSDL chosen does not belong to the family enabled
for EMCSFAMA1DL, i.e. EMCSFAMAP1DL, EMCSFAMB1DL,
EMCSFAMCDL, EMCSFAMGDL.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
If the BCCH is involved in a BBHOP hopping law and the BCCH
TRX has TRXMD=EDGE, EBCCHTRX cannot be set at
FALSE.
GPRS_TSC_INCONSISTENT
If the EGPRS flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in GLLPRM/GLLCOM, single TCHs on
timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to
the layers contained in GLLPRM/GLLCOM all single TCHs
must have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
GPRS_HOPP_INCONSISTENT


976 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
If the EGPRS flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in GLLPRM/GLLCOM, single TCHs on
timeslot from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in GLLPRM/GLLCOM, different from the
BCCH one, all single TCHs must have the same FHSYD and
MAIO.
If the DTMSUP flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet
Services in Primary area, single TCHs on timeslot from 1 to 7
must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet
Services in Primary area, different from the BCCH one, all
single TCHs must have the same FHSYD and MAIO.
EDGE_TSC_INCONSISTENT
If the EEDGE flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, single TCHs on
timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, all single TCHs
must have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
EDGE_HOPP_INCONSISTENT


A30808-X3247-M230-6-7619

977
CML:BSC PTPPKF
Id:0900d805800d5658
Application Guidelines:
1. The value of BSPBBLK, BPAGCHR and BPRACHR parameters has to be set in
such a way to have at least one block of each of the following types:
PBCCH, PPCH, PAGCH for DL;
PRACH for UL.
For instance, if BSPBBLK is set at 1 the maximum value for BPAGCHR is 9.
2. The difference between the "ThresholdIdleChanVH" and "ThresholdIdleChanHV"
fields of GASTRTH parameter has to be set at a value not too much high, in order
to have a real hysteresis behaviour.
3. The following relationships must be verified:
NCTRFPSCTH < = CRESELTRHSOUT
NCTRFPSCTH > CRESELTRHINP
4. The maximum admitted value of the GMANPRES attribute is equal to 190. This
attribute is meaningful only for the first shared layer. When setting the value of this
attribute, the operator must pay attention about how many shared layers are
equipped, and how many timeslots he would like to reserve to GPRS/EGPRS ser-
vices, otherwise he could lose all circuit switched traffic.
5. The value of BSPBBLK and BPAGCHR parameters has to be set in such way to
have at least one block of any type:
- PBCCH, PPCH, PAGCH for DL;
- PRACH and PDTCH/PACCH for UL.
For instance if BSPBBLK is set to 1 the maximum value for BPAGCHR is 9.
Example of Command Execution:
Set PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0,RACODE=1,RACOL=5,BSCDVMA=5,
PKTNDEC=6,PKTNINC=7,PKTNMA=0,GRXLAMI=10,GMSTXPMAC=20,ABU-
TYP=0,RAARET=0,GPATH=2,GTXINT=9,GS=3,GMANRETS=2,GMANMSAL=7-9,
T3166_68=3,T3192=2,INICSCH=CS1,GCELLRESH=7,C31H=0,RARESH=6,GHC-
STH=11,GHCSPC=4, ALPHA=8,TAVGW=15,TAVGT=7,PRPB-
CCH=12,PCMECH=0,NAVGI=9,
BSPBBLK=0,BPAGCHR=5,PBRACHR=8,DRXTMA=4,CACKTYP=1,
If the EEDGE flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, single TCHs on
timeslot from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in ELLPRM/ELLCOM, different from the
BCCH one, all single TCHs must have the same FHSYD and
MAIO.


978 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5658
PTPPKF
GASTRTH=10-20-20,GPDPDTCHA=0,QSRHPRI=UMDB82,FDDGQO=DB08,
GMANPRESCOM=0,GMANPRESPRM=0, EMANPRESCOM=0, EMANPRE-
SPRM=0,TRFPSCTRLT=5, NTWCREPPTR=MSEC480, NTWCREP-
PIDL=MSEC61440, NTWCNDRXP=MSEC960, CRESELTRHSOUT=85,
GUMTSSRHPRI=FALSE, GFDDQMI=MDB18, TDDGQO=DB16,GFD-
DREPQTY=RSCP, GNMULBAC=2, GFDDMURREP=1, GTDDMUR-
REP=1,CSCH3CSCH4SUP=FALSE,BVCBHIPER=70,
BVCBSPPER=PER200,BVCBMAPER=PER100,BVCBLPER=PER60,
MSBSPPER=PER200,MSBHIPER=PER70,MSBMAPER=PER100,
MSBLPER=PER60,ELKADPT=FALSE,BLERAVEUL=UNIT400,
BLERAVEDL=UNIT400,EMFA1UNIR8PSK=TRUE,EMFA1UNIR8PSK=FALSE,
EMFB1UNIR8PSK=FALSE,EMFCUNIR8PSK=FALSE,EMFGUNIR8PSK=FALSE,
EMFCUNIRGMSK=FALSE,EMFGUNIRGMSK=TRUE,EMCSFAMA1DL=TRUE,
EMCSFAMAP1DL=FALSE,EMCSFAMB1DL=FALSE,EMCSFAMCDL=FALSE,
EMCSFAMGDL=FALSE,IMCSULNIR8PSK=MCS6,IMCSULNIRGMSK=MCS3,
INIMCSDL=MCS9,RAENV=HIGHDIV,STGTTLLIINF=60,INIBLER=PER20,
SCHWEIPRI1=7,SCHWEIPRI2=6,SCHWEIPRI3=5,SCHWEIPRI4=2,
EBCCHTRX=FALSE,EEDGE=TRUE,EGPRS=TRUE,BEPAVGP=5,
EGWSONETS=192,EGWSTWOTS=256,EGWSTHREETS=384,EGWSFOURTS=512,
EGWSFIVETS=640,EGWSSIXTS=768,EGWSSEVENTS=896,
EGWSEIGHTTS=1024,EGPLGPONETS=16,EGPLGPTWOTS=16,
EGPLGPTHREETS=16,EGPLGPFOURTS=16,EGPLGPFIVETS=16,
EGPLGPSIXTS=16,EGPLGPSEVENTS=16,EGPLGPEIGHTTS=16,
PERSTLVPRI1=5,PERSTLVPRI2=5,PERSTLVPRI3=5,PERSTLVPRI4=5,
NCC1TH=DB03,NCRARESH=DB00,NCSAMERA=TRUE, NCTRFPSCTH=75, CRE-
SELTRHINP=66, PKTMEASREPCNT=1, BEPFIDLWEI=1, SMSINFO=1-160, SPFI-
WEI=16, INTRTRFH1WEI=8, INTRTRFH2WEI=4, INTRTRFH3WEI=2, BCGRWEI=1,
STREAMWEI=32, TFAILNCU=5, MAFAILNCU=5, TBNCU=5, EUMSSNCRE-
SEL=FALSE, CPCUN=1, MSRMAXU=FALSE, FPER=15, PFCIBMAPER=100, PFCIB-
MAPPER=200, PFCIBHIPER=70, PFCIBLPER=60, PFCBBMAPER=100,
PFCBBMAPPER=200, PFCBBHIPER=70, PFCBBLPER=60, PFCSBMAPER=100,
PFCSBMAPPER=200, PFCSBHIPER=70, PFCSBLPER=60, PFCIRMAXU=FALSE,
PFCBRMAXU=FALSE, PFCSRMAXU=FALSE, PFCIRPER=100, PFCBRPER=100,
PFCSRPER=100, GFDDRSCPMI=MDB101, GFDDQMIO=DB00, LLCDVOL-
TRSH=0;EDTMSUP=DISABLED, EEDGE=FALSE;
UNLOCK PTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF UNLOCK
PTPPKF
UNLOCK PTPPKF NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0;


A30808-X3247-M230-6-7619

979
CML:BSC PTPPKF
Id:0900d805800d5658
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command removes the operator block and the unit remains in the operational state
as it is at the moment of the command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_INVALID_STATUS
Application Guidelines:
None.
Example of Command Execution:
Unlock PTPPKF:NAME=BTSM:0/BTS:0/PTPPKF:0;


980 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PWRC
The PWRC object represents the parameters used in the power control algorithm. There
is one instance for each cell controlled by the BSC.
GET PWRC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PWRC GET PWRC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the attributes of the powerControl object, modeling the
power control algorithm used with a MS/BTS and containing the attributes which are
generic to any power control algorithm.
Long Names:
NAME Addres of the managed object
EBSPWRC enableBSPowerControl
EMSPWRC enableMSPowerControl
PWRINCSS powerIncrStepSize
PWREDSS powerRedStepSize
PWRCONF powerConfirm
PCONINT powerControlInterval
PAVRLEV pcAveragingLev
PAVRQUAL pcAveragingQual
LOWTLEVD pcLowerThresholdLevDL
UPTLEVD pcUpperThresholdLevDL
LOWTLEVU pcLowerThresholdLevUL
GET PWRC NAME=BTSM:0..199/BTS:0..23/PWRC:0..0 [,REQATTL=
EBSPWRC ,EMSPWRC ,PWRINCSS ,PWREDSS
,PWRCONF ,PCONINT ,PAVRLEV ,PAVRQUAL
,LOWTLEVD ,UPTLEVD ,LOWTLEVU ,UPTLEVU
,LOWTQUAD ,UPTQUAD ,LOWTQUAU ,UPTQUAU
,RDLNKTBS ,EPWCRLFW ,PCRLFTH ,EBSPWCR
,LOWTQUAMRDL ,LOWTQUAMRUL ,UPTQUAMRDL
,UPTQUAMRUL ,SG1PCPAR ,SG2PCPAR ,SG3PCPAR
,SG4PCPAR ,SG5PCPAR ,SG6PCPAR ,SG7PCPAR
,SG8PCPAR ,SG9PCPAR ,SG10PCPAR ,SG11PCPAR
,SG12PCPAR ,SG13PCPAR ,SG14PCPAR ,PCMBSTX-
PRL];


A30808-X3247-M230-6-7619

981
CML:BSC PWRC
Id:0900d805800d42ab
UPTLEVU pcUpperThresholdLevUL
LOWTQUAD pcLowerThresholdQualDL
UPTQUAD pcUpperThresholdQualDL
LOWTQUAU pcLowerThresholdQualUL
UPTQUAU pcUpperThresholdQualUL
RDLNKTBS radioLinkTimeoutBs
EPWCRLFW enablePowerControlRLFW
PCRLFTH pcRLFThreshold
EBSPWCR enableBSPwrCorrection
LOWTQUAMRDL pcLowerThresQualAMRDL
LOWTQUAMRUL pcLowerThresQualAMRUL
UPTQUAMRDL pcUpperThresQualAMRDL
UPTQUAMRUL pcUpperThresQualAMRUL
SG1PCPAR sg1PowerControlParms
SG2PCPAR sg2PowerControlParms
SG3PCPAR sg3PowerControlParms
SG4PCPAR sg4PowerControlParms
SG5PCPAR sg5PowerControlParms
SG6PCPAR sg6PowerControlParms
SG7PCPAR sg7PowerControlParms
SG8PCPAR sg8PowerControlParms
SG9PCPAR sg9PowerControlParms
SG10PCPAR sg10PowerControlParms
SG11PCPAR sg11PowerControlParms
SG12PCPAR sg12PowerControlParms
SG13PCPAR sg13PowerControlParms
SG14PCPAR sg14PowerControlParms
PCMBSTXPRL pcMaxBsTxPowerRedLev
System Responses:
- Operation Completed
NAME:name
EBSPWRC:enableBsPowerContro
EMSPWRC:enableMsPowerContro
PWRINCSS:powerIncrStepSize
PWREDSS:powerRedStepSize
PWRCONF:powerConfirm
PCONINT:powerControlInterva
PAVRLEV:pcAveragingLev


982 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PAVRQUAL:pcAveragingQual
LOWTLEVD:pcLowerThresholdLevDL
UPTLEVD:pcUpperThresholdLevDL
LOWTLEVU:pcLowerThresholdLevUL
UPTLEVU:pcUpperThresholdLevUL
LOWTQUAD:pcLowerThresholdQualDL
UPTQUAD:pcUpperThresholdQualDL
LOWTQUAU:pcLowerThresholdQualUL
UPTQUAU:pcUpperThresholdQualUL
RDLNKTBS:radioLinkTimeoutBs
EPWCRLFW:enablePowerControlRLFW
PCRLFTH:pcRLFThreshold
EBSPWCR:enableBsPwrCorrection
LOWTQUAMRDL:pcLowerThresQualAMRDL
LOWTQUAMRUL:pcLowerThresQualAMRUL
UPTQUAMRDL:pcUpperThresQualAMRDL
UPTQUAMRUL:pcUpperThresQualAMRUL
SG1PCPAR:sg1PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG2PCPAR:sg2PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW


A30808-X3247-M230-6-7619

983
CML:BSC PWRC
Id:0900d805800d42ab
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG3PCPAR:sg3PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG4PCPAR:sg4PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL


984 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG5PCPAR:sg5PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG6PCPAR:sg6PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs


A30808-X3247-M230-6-7619

985
CML:BSC PWRC
Id:0900d805800d42ab
PcRadioLinkTimeoutMs
SG7PCPAR:sg7PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG8PCPAR:sg8PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG9PCPAR:sg9PowerControlParms
EnableBSPowerControl
EnableMSPowerControl


986 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG10PCPAR:sg10PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG11PCPAR:sg11PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold


A30808-X3247-M230-6-7619

987
CML:BSC PWRC
Id:0900d805800d42ab
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG12PCPAR:sg12PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG13PCPAR:sg13PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs


988 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
GET PWRC BASICS
SG14PCPAR:sg14PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
PCMBSTXPRL:pcMaxBsTxPowerRedLev
NAME: name
EBSPWRC: enableBsPowerControl
EMSPWRC: enableMsPowerControl
PWRINCSS powerIncrStepSize
PWREDSS: powerRedStepSize
PWRCONF: powerConfirm
PCONINT: powerControlInterval
PAVRLEV: pcAverangingLev
PAVRQUAL: pcAverangingQual
LOWTLEVD: pcLowerThresholdLevDL
UPTLEVD: pcUpperThresholdLevDL
LOWTLEVU: pcLowerThresholdLevUL
UPTLEVU: pcUpperThresholdLevUL
LOWTQUAD: pcLowerThresholdQualDL
UPTQUAD: pcUpperThresholdQualDL
LOWTQUAU: pcLowerThresholdQualUL
UPTQUAU: pcUpperThresholdQualUL
RDLNKTBS: radioLinkTimeoutBs


A30808-X3247-M230-6-7619

989
CML:BSC PWRC
Id:0900d805800d42ab
EPWCRLFW: enablePowerControlRLFW
PCRLFTH: pcRLFThreshold
EBSPWCR: enableBsPwrCorrection
LOWTQUAMRDL:pcLowerThresQualAMRDL
LOWTQUAMRUL:pcLowerThresQualAMRUL
UPTQUAMRDL:pcUpperThresQualAMRDL
UPTQUAMRUL:pcUpperThresQualAMRUL
SG1PCPAR:sg1PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG2PCPAR:sg2PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs


990 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PcRadioLinkTimeoutMs
SG3PCPAR:sg3PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG4PCPAR:sg4PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG5PCPAR:sg5PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL


A30808-X3247-M230-6-7619

991
CML:BSC PWRC
Id:0900d805800d42ab
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG6PCPAR:sg6PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG7PCPAR:sg7PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL


992 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG8PCPAR:sg8PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutMs
PcRadioLinkTimeoutBs
SG9PCPAR:sg9PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG10PCPAR:sg10PowerControlParms
EnableBSPowerControl


A30808-X3247-M230-6-7619

993
CML:BSC PWRC
Id:0900d805800d42ab
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresholdQualDL
PcLowerThresholdQualUL
PcUpperThresholdQualDL
PcUpperThresholdQualUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG11PCPAR:sg11PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG12PCPAR:sg12PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL


994 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG13PCPAR:sg13PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs
PcRadioLinkTimeoutMs
SG14PCPAR:sg14PowerControlParms
EnableBSPowerControl
EnableMSPowerControl
EnablePowerControlRLFW
PcLowerThresholdLevDL
PcLowerThresholdLevUL
PcUpperThresholdLevDL
PcUpperThresholdLevUL
PcRLFThreshold
PcLowerThresQualAMRDL
PcLowerThresQualAMRUL
PcUpperThresQualAMRDL
PcUpperThresQualAMRUL
PcRadioLinkTimeoutBs


A30808-X3247-M230-6-7619

995
CML:BSC PWRC
Id:0900d805800d42ab
- Operation Failed
Application Guidelines:
None.
GET PWRC BASICS
None.
Example of Command Execution:
Get PWRC:NAME=BTSM:0/BTS:0/PWRC:0,REQATTL=EBSPWRC&EMSPWRC&
PWRINCSS&PWREDSS&PWRCONF&PCONINT&PAVRLEV&PAVRQUAL&
LOWTLEVD&UPTLEVD&LOWTLEVU&UPTLEVU&LOWTQUAD&UPTQUAD&
LOWTQUAU&UPTQUAU&RDLNKTBS&EPWCRLFW&PCRLFTH&EBSPWCR&
LOWTQUAMRDL&LOWTQUAMRUL&UPTQUAMRDL&UPTQUAMRUL&
SG1PCPAR&SG2PCPAR&SG3PCPAR&SG4PCPAR&SG5PCPAR&SG6PCPAR&
SG7PCPAR&SG8PCPAR&SG9PCPAR&SG10PCPAR&SG11PCPAR&
SG12PCPAR&SG13PCPAR&SG14PCPAR&PCMBSTXPRL;
GET PWRC BASICS
Get PWRC BASICS:NAME=BTSM:0/BTS:0/PWRC:0;
GET PWRC BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PWRC GET PWRC
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the attributes of the powerControl object, modeling the
power control algorithm used with a MS/BTS and containing the attributes which are
generic to any power control algorithm.
PcRadioLinkTimeoutMs
PCMBSTX-
PRL:
pcMaxBsTxPowerRedLev
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET PWRC BASICS NAME=BTSM:0..199/BTS:0..23/PWRC:0..0;


996 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
Long Names:
NAME Addres of the managed object
EBSPWRC enableBSPowerControl
EMSPWRC enableMSPowerControl
PWRINCSS powerIncrStepSize
PWREDSS powerRedStepSize
PWRCONF powerConfirm
PCONINT powerControlInterval
PAVRLEV pcAveragingLev
PAVRQUAL pcAveragingQual
LOWTLEVD pcLowerThresholdLevDL
UPTLEVD pcUpperThresholdLevDL
LOWTLEVU pcLowerThresholdLevUL
UPTLEVU pcUpperThresholdLevUL
LOWTQUAD pcLowerThresholdQualDL
UPTQUAD pcUpperThresholdQualDL
LOWTQUAU pcLowerThresholdQualUL
UPTQUAU pcUpperThresholdQualUL
RDLNKTBS radioLinkTimeoutBs
EPWCRLFW enablePowerControlRLFW
PCRLFTH pcRLFThreshold
EBSPWCR enableBSPwrCorrection
LOWTQUAMRDL pcLowerThresQualAMRDL
LOWTQUAMRUL pcLowerThresQualAMRUL
UPTQUAMRDL pcUpperThresQualAMRDL
UPTQUAMRUL pcUpperThresQualAMRUL
SG1PCPAR sg1PowerControlParms
SG2PCPAR sg2PowerControlParms
SG3PCPAR sg3PowerControlParms
SG4PCPAR sg4PowerControlParms
SG5PCPAR sg5PowerControlParms
SG6PCPAR sg6PowerControlParms
SG7PCPAR sg7PowerControlParms
SG8PCPAR sg8PowerControlParms
SG9PCPAR sg9PowerControlParms
SG10PCPAR sg10PowerControlParms
SG11PCPAR sg11PowerControlParms
SG12PCPAR sg12PowerControlParms
SG13PCPAR sg13PowerControlParms


A30808-X3247-M230-6-7619

997
CML:BSC PWRC
Id:0900d805800d42ab
SG14PCPAR sg14PowerControlParms
PCMBSTXPRL pcMaxBsTxPowerRedLev
System Responses:
See GET PWRC
Application Guidelines:
See GET PWRC
Example of Command Execution:
See GET PWRC
SET PWRC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PWRC SET PWRC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the attributes of the powerControl object, modeling the power
control algorithm used with a MS/BTS and containing the attributes which are generic to
any power control algorithm.
Long Names:
NAME Addres of the managed object
EBSPWRC enableBSPowerControl
EMSPWRC enableMSPowerControl
PWRINCSS powerIncrStepSize
PWREDSS powerRedStepSize
PWRCONF powerConfirm
SET PWRC NAME=BTSM:0..199/BTS:0..23/PWRC:0..0 [,EBSPWRC=]
[,EMSPWRC=] [,PWRINCSS=] [,PWREDSS=] [,PWR-
CONF=] [,PCONINT=] [,PAVRLEV=] [,PAVRQUAL=]
[,LOWTLEVD=] [,UPTLEVD=] [,LOWTLEVU=]
[,UPTLEVU=] [,LOWTQUAD=] [,UPTQUAD=]
[,LOWTQUAU=] [,UPTQUAU=] [,RDLNKTBS=] [,EPWCR-
LFW=] [,PCRLFTH=] [,EBSPWCR=] [,LOWTQUAMRDL=]
[,LOWTQUAMRUL=] [,UPTQUAMRDL=] [,UPTQUAM-
RUL=] [,SG1PCPAR=] [,SG2PCPAR=] [,SG3PCPAR=]
[,SG4PCPAR=] [,SG5PCPAR=] [,SG6PCPAR=]
[,SG7PCPAR=] [,SG8PCPAR=] [,SG9PCPAR=]
[,SG10PCPAR=] [,SG11PCPAR=] [,SG12PCPAR=]
[,SG13PCPAR=] [,SG14PCPAR=] [,PCMBSTXPRL=];


998 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
PCONINT powerControlInterval
PAVRLEV pcAveragingLev
PAVRQUAL pcAveragingQual
LOWTLEVD pcLowerThresholdLevDL
UPTLEVD pcUpperThresholdLevDL
LOWTLEVU pcLowerThresholdLevUL
UPTLEVU pcUpperThresholdLevUL
LOWTQUAD pcLowerThresholdQualDL
UPTQUAD pcUpperThresholdQualDL
LOWTQUAU pcLowerThresholdQualUL
UPTQUAU pcUpperThresholdQualUL
RDLNKTBS radioLinkTimeoutBs
EPWCRLFW enablePowerControlRLFW
PCRLFTH pcRLFThreshold
EBSPWCR enableBSPwrCorrection
LOWTQUAMRDL pcLowerThresQualAMRDL
LOWTQUAMRUL pcLowerThresQualAMRUL
UPTQUAMRDL pcUpperThresQualAMRDL
UPTQUAMRUL pcUpperThresQualAMRUL
SG1PCPAR sg1PowerControlParms
SG2PCPAR sg2PowerControlParms
SG3PCPAR sg3PowerControlParms
SG4PCPAR sg4PowerControlParms
SG5PCPAR sg5PowerControlParms
SG6PCPAR sg6PowerControlParms
SG7PCPAR sg7PowerControlParms
SG8PCPAR sg8PowerControlParms
SG9PCPAR sg9PowerControlParms
SG10PCPAR sg10PowerControlParms
SG11PCPAR sg11PowerControlParms
SG12PCPAR sg12PowerControlParms
SG13PCPAR sg13PowerControlParms
SG14PCPAR sg14PowerControlParms
PCMBSTXPRL pcMaxBsTxPowerRedLev
System Responses:
- Operation Completed
Successful
- Operation Failed


A30808-X3247-M230-6-7619

999
CML:BSC PWRC
Id:0900d805800d42ab
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
- the attribute RDLNKTBS must be a multiple of 4.
- the following inequality must be satisfied: PCRLFTH < RDLNKTBS.
For every SGXPCPAR, X = 1..14:
If SGXPCPAR is different from NULL value, the following inequality must
be satisfied: SGXPCPAR.pcRLFThreshold < VAL (SGXPCPAR.radi-
oLinkTimeoutBs) where
VAL (SGXPCPAR.radioLinkTimeoutBs) = (SGXPCPAR.radioLinkTime-
outBs+1)*4
INCOMP_NESWLOAD_VS_MESSAGE
If the SW Version running on the superordinate BTSM object belongs to
BR7.0 release (see EXPSWV parameter description) the NULL value is
not allowed for the new parameter PCMBSTXPRL.
If the SW Version running on the superordinate BTSM object belongs to
BR6.0 release (see EXPSWV parameter description) the only value
allowed for the new parameter PCMBSTXPRL is NULL.
If the SW Version running on the superordinate BTSM object belongs to
BR6.0 release (see EXPSWV parameter description) the EBSPWRC
and EMSPWRC attributes can assume only DISABLED and CLASSIC
values; ADAPTIVE value is not accepted.
When the SGXPCPAR attribute, X = 1..14, is different from NULL,
SGXPCPAR fields override the unspecific attributes shared among
service groups, as shown in Appendix C.
For every SGXPCPAR, X = 1..14: the attribute must be set at NULL value
if the Expected SW Version (see EXPSWV parameter description)
belongs to BR6.0 release.


1000 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ab
PWRC
Application Guidelines:
1. When the BS power control is enabled (EBSPWRC attribute) the following attributes
are relevant:
2. When the MS power control is enabled (EMSPWRC attribute) the following
attributes are relevant:
3. When the MS and BS power control procedure due to radio link failure warning is
enabled (EPWCRLFW attribute) the following attributes are relevant:
4. Due to the mapping averaged RXQUAL <-> C/I (see Tab. 6.15), the following
parameters should not exceed 20 dB or be less than 1 dB: LOWTQUAMRDL,
LOWTQUAMRUL, UPTQUAMRDL, UPTQUAMRUL. Any setting above 20 dB will
not be rejected by the system, but the related power control process will be affected
consequently, as the related threshold will never be reached.
5. For every SGXPCPAR, X = 1..14: if at least one of the SGXPCPAR attribute fields
is set at a valid value, also all the other attribute fields must be set at a valid value.
Example of Command Execution:
Set PWRC:NAME=BTSM:0/BTS:0/PWRC:0,EBSPWRC=TRUE,EMSPWRC=TRUE,
powerIncrStepSize PWRC:PWRINCSS
powerRedStepSize PWRC:PWREDSS
pcAveragingLev PWRC:PAVRLEV
pcAveragingQual PWRC:PAVRQUAL
pcLowerThresholdLevDL PWRC:LOWTLEVD
pcLowerThresholdQualDL PWRC:LOWTQUAD
pcUpperThresholdLevDL PWRC:UPTLEVD
pcUpperThresholdQualDL PWRC:UPTQUAD
powerControlInterval PWRC:PCONINT
powerConfirm PWRC:PWRCONF
powerIncrStepSize PWRC:PWRINCSS
powerRedStepSize PWRC:PWREDSS
pcAveragingLev PWRC:PAVRLEV
pcAveragingQual PWRC:PAVRQUAL
pcLowerThresholdLevUL PWRC:LOWTLEVU
pcLowerThresholdQualUL PWRC:LOWTQUAU
pcUpperThresholdLevUL PWRC:UPTLEVU
pcUpperThresholdQualUL PWRC:UPTQUAU
pcRFLThreshold PWRC:PCRLFTH
radioLinkTimeoutBs PWRC:RDLNKTBS


A30808-X3247-M230-6-7619

1001
CML:BSC PWRC
Id:0900d805800d42ab
PWRINCSS=db4,PWREDSS=db2,PWRCONF=31,PCONINT=31,PAVRLEV=31-3,
PAVRQUAL=31-3,LOWTLEVD=63,UPTLEVD=63, LOWTLEVU=63,UPTLEVU=63,
LOWTQUAD=7,UPTQUAD=7,LOWTQUAU=7,UPTQUAU=7, RDLNKTBS=64,
EPWCRLFW=TRUE,PCRLFTH=64,EBSPWCR=FALSE,LOWTQUAMRDL=1,
LOWTQUAMRUL=2,UPTQUAMRDL=3,UPTQUAMRUL=4,
SG1PCPAR=CLASSIC-CLASSIC-TRUE-20-15-20-5-10-5-5-5-5-NULL-NULL,
SG2PCPAR=CLASSIC-CLASSIC-TRUE-20-15-20-5-10-4-4-4-4-NULL-NULL,
SG3PCPAR=CLASSIC-CLASSIC-TRUE-20-12-20-5-10-4-4-4-4-NULL-NULL,
SG4PCPAR=CLASSIC-CLASSIC-TRUE-20-12-20-5-10-6-6-6-6-NULL-NULL,
SG5PCPAR=CLASSIC-CLASSIC-TRUE-18-12-20-5-10-4-4-4-4-NULL-NULL,
SG6PCPAR=CLASSIC-CLASSIC-TRUE-21-12-20-5-10-4-4-4-4-NULL-NULL,
SG7PCPAR=CLASSIC-CLASSIC-TRUE-21-12-20-5-10-3-3-3-3-NULL-NULL,
SG8PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-3-3-3-3-NULL-NULL,
SG9PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-3-3-3-3-NULL-NULL,
SG10PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-3-3-3-3-NULL-NULL,
SG11PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15-NULL-NULL,
SG12PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15-NULL-NULL,
SG13PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15-NULL-NULL,
SG14PCPAR=CLASSIC-CLASSIC-TRUE-21-14-20-5-10-15-15-15-15-NULL-NULL,
PCMBSTXPRL=15;


1002 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ae
PWRD
PWRD
The PWRD object represents the power distributor of the supply voltage for the BSC
base module.
GET PWRD STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD GET PWRD STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
PWRD object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get PWRD STAT:NAME=PWRD:0;
GET PWRD STAT NAME=PWRD:0..1;


A30808-X3247-M230-6-7619

1003
CML:BSC PWRD
Id:0900d805800d42ae
GETRELATIONSHIP PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD GETRELATIONSHIP
PWRD
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.
For the PWRD object the MEL is the related FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship PWRD:NAME=PWRD:0;
GETSUBO PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD GETSUBO PWRD
GETRELATIONSHIP
PWRD
NAME=PWRD:0..1;
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object instance does not provide any relationship attribute.
GETSUBO PWRD NAME=PWRD:0..1;


1004 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ae
PWRD
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
None.
Application Guidelines:
None.
Example of Command Execution:
Getsubo PWRD:NAME=PWRD:0;
GETTEST PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD GETTEST PWRD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
GETTEST PWRD NAME=PWRD:0..1;


A30808-X3247-M230-6-7619

1005
CML:BSC PWRD
Id:0900d805800d42ae
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest PWRD:NAME=PWRD:0;
LOCK PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD LOCK PWRD
GETTEST PWRD:NAME=PWRD:0;
name = TEST:<n>
mOts = LICDS:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK PWRD NAME=PWRD:0..1;


1006 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ae
PWRD
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock PWRD:NAME=PWRD:0;
PERFTEST PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD PERFTEST PWRD
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state.
PERFTEST PWRD NAME=PWRD:0..1;


A30808-X3247-M230-6-7619

1007
CML:BSC PWRD
Id:0900d805800d42ae
Command Description:
This command is used to perform a test on the selected PWRD object; the test consist
of the following phases:
Power-on Test (start phase),
Basic Maintenance Test (WP1),
Full Maintenance Test (WP2),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST PWRD:NAME=PWRD:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases


1008 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ae
PWRD
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The test can be executed with the object in UNLOCKED administrative state.
2. When a test starts on an object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest PWRD:NAME=PWRD:0;
STOPTEST PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD STOPTEST PWRD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests are possible.
STOPTEST PWRD NAME=PWRD:0..1;


A30808-X3247-M230-6-7619

1009
CML:BSC PWRD
Id:0900d805800d42ae
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
STOPTEST PWRD:NAME=PWRD:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = PWRD:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.


1010 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ae
PWRD
Example of Command Execution:
Stoptest PWRD:NAME=PWRD:0;
UNLOCK PWRD
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE PWRD UNLOCK PWRD
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
It is possible to unlock the PWRD card with the status in LOCKED and UNDER TEST.
Example of Command Execution:
Unlock PWRD:NAME=PWRD:0;
UNLOCK PWRD NAME=PWRD:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


A30808-X3247-M230-6-7619

1011
CML:BSC QSMONBSC
Id:0900d805800d42b1
QSMONBSC
The QSMONBSC object is used to monitor the Quality of Service indicator.
CREATE QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC CREATE QSMONBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the QSMONBSC object class. .
Long Names:
NAME Addres of the managed object
TDPCPRCSLD tdpcProcessorLoad
PCUPRCSLD pcuProcessorLoad
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Create QSMONBSC:NAME=QSMONBSC=0, TDPCPRCSLD=NULL, PCUPRC-
SLD=NULL, SUPPER=MINUTES_5;
CREATE QSMONBSC NAME=QSMONBSC:0..0 [,TDPCPRCSLD=] [,PCUPRC-
SLD=] [,SUPPER=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_WRONG_LIST_OF_QOSINDICATOR
At least one attribute "QoS Indicator" must be present.
UNSUCCESSFUL_THRESHOLD_SET_NOTEQUIPPED
The QSTHRS object instance must be already equipped.


1012 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b1
QSMONBSC
DELETE QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC DELETE QSMONBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the QSMONBSC object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete QSMONBSC:NAME=QSMONBSC:0;
GET QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC GET QSMONBSC
DELETE QSMONBSC NAME=QSMONBSC:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a QSMONBSC, the relative object instance must be in
LOCKED state.
GET QSMONBSC NAME=QSMONBSC:0..0 [,REQATTL= TDPCPRCSLD
,PCUPRCSLD ,SUPPER];


A30808-X3247-M230-6-7619

1013
CML:BSC QSMONBSC
Id:0900d805800d42b1
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
QSMONBSC object class.
Long Names:
NAME Addres of the managed object
TDPCPRCSLD tdpcProcessorLoad
PCUPRCSLD pcuProcessorLoad
SUPPER supervisionPeriod
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get QSMONBSC:NAME=QSMONBSC:0,REQATTL=TDPCPRCSLD&PCUPRC-
SLD&SUPPER;
GET QSMONBSC BASICS
NAME: name
TDPCPRCSLD: tdpcProcessorLoad
PCUPRCSLD: pcuProcessorLoad
SUPPER supper
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already
equipped.
GET QSMONBSC
BASICS
NAME=QSMONBSC:0..0;


1014 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b1
QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC GET QSMONBSC
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
QSMONBSC object class.
Long Names:
NAME Addres of the managed object
TDPCPRCSLD tdpcProcessorLoad
PCUPRCSLD pcuProcessorLoad
SUPPER supervisionPeriod
System Responses:
See GET QSMONBSC
Application Guidelines:
See GET QSMONBSC
Example of Command Execution:
See GET QSMONBSC
GET QSMONBSC STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC GET QSMONBSC
STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command allows to display the administrative, operational, usage state and all the
status attributes of a specified object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GET QSMONBSC STAT NAME=QSMONBSC:0..0;


A30808-X3247-M230-6-7619

1015
CML:BSC QSMONBSC
Id:0900d805800d42b1
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get QSMONBSC STAT:NAME=QSMONBSC:0;
GETCURRENTVALUE QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC GETCURRENTVALUE
QSMONBSC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to have a snapshot of the QoS BSC current status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVALUE
QSMONBSC
NAME=QSMONBSC:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
It is not possible to perform the command.
UNSUCCESSFUL_INVALID_STATUS
Qsmon is off_duty.


1016 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b1
QSMONBSC
Application Guidelines:
None
Example of Command Execution:
GetCurrentValues QSMONBSC:NAME=QSMONBSC:0;
LOCK QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC LOCK QSMONBSC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The administrative state Locked will survive at the Full Init (and consequently to the
load database).
Example of Command Execution:
Lock QSMONBSC:NAME=QSMONBSC:0;
LOCK QSMONBSC NAME=QSMONBSC:0..0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state


A30808-X3247-M230-6-7619

1017
CML:BSC QSMONBSC
Id:0900d805800d42b1
SET QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC SET QSMONBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the QSMONBSC object class.
Long Names:
NAME Addres of the managed object
TDPCPRCSLD tdpcProcessorLoad
PCUPRCSLD pcuProcessorLoad
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set QSMONBSC:NAME=QSMONBSC=0, TDPCPRCSLD=NULL, PCUPRC-
SLD=NULL, SUPPER=MINUTES_5;
SET QSMONBSC NAME=QSMONBSC:0..0 [,TDPCPRCSLD=] [,PCUPRC-
SLD=] [,SUPPER=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object is not already created.
UNSUCCESSFUL_WRONG_LIST_OF_QOSINDICATOR
At least one attribute "QoS Indicator" must be present.
UNSUCCESSFUL_THRESHOLD_SET_NOTEQUIPPED
The QSTHRS object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The administrative state is not LOCKED.


1018 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b1
QSMONBSC
UNLOCK QSMONBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBSC UNLOCK QSMONBSC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock QSMONBSC:NAME=QSMONBSC:0;
UNLOCK QSMONBSC NAME=QSMONBSC:0..0;
ALREADY_IN_TARGET_STATE
The selected object is in administrative state
"Unlocked".
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.


A30808-X3247-M230-6-7619

1019
CML:BSC QSMONBTS
Id:0900d805800d42b4
QSMONBTS
The QSMONBTS object is used to monitor the Quality of Service indicator.
CREATE QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS
CREATE QSMONBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the QSMONBTS object class. .
Long Names:
NAME Addres of the managed object
TCHDROR tCHDropRate
SDCCHDROR sDCCHDropRate
IMMASSFAIR immediateAssignmentFailureRate
ASSFAIR assignmentFailureRate
CLSETFAIR callSetupFailureRate
TCHLOSR tCHLossRate
SDCCHLOSR sDCCHLossRate
HANDROR handoverDropRate
HANFAIR handoverFailureRate
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE QSMONBTS NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0 [,TCH-
DROR=] [,SDCCHDROR=] [,IMMASSFAIR=] [,ASSFAIR=]
[,CLSETFAIR=] [,TCHLOSR=] [,SDCCHLOSR=] [,HAN-
DROR=] [,HANFAIR=] [,SUPPER=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.


1020 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b4
QSMONBTS
Application Guidelines:
None.
Example of Command Execution:
Create QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS:0, TCHDROR=NULL, SDC-
CHDROR=NULL, IMMASSFAIR=NULL, ASSFAIR=NULL, CLSETFAIR=NULL,
TCHLOSR=NULL, SDCCHLOSR=NULL, HANDROR=NULL, HANFAIR=NULL, SUP-
PER=MINUTES_5;
DELETE QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS
DELETE QSMONBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the QSMONBTS object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_WRONG_LIST_OF_QOSINDICATOR
At least one attribute "QoS Indicator" must be present.
UNSUCCESSFUL_THRESHOLD_SET_NOTEQUIPPED
The QSTHRS object instance must be already equipped.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The BTS object instance must be already equipped.
DELETE QSMONBTS NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

1021
CML:BSC QSMONBTS
Id:0900d805800d42b4
Application Guidelines:
None.
Example of Command Execution:
Delete QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS:0;
GET QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS GET
QSMONBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
QSMONBTS object class.
Long Names:
NAME Addres of the managed object
TCHDROR tCHDropRate
SDCCHDROR sDCCHDropRate
IMMASSFAIR immediateAssignmentFailureRate
ASSFAIR assignmentFailureRate
CLSETFAIR callSetupFailureRate
TCHLOSR tCHLossRate
SDCCHLOSR sDCCHLossRate
HANDROR handoverDropRate
HANFAIR handoverFailureRate
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Before deleting a QSMONBTS, the relative object instance must be in
LOCKED state.
GET QSMONBTS NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0
[,REQATTL= TCHDROR ,SDCCHDROR ,IMMASSFAIR
,ASSFAIR ,CLSETFAIR ,TCHLOSR ,SDCCHLOSR
,HANDROR ,HANFAIR ,SUPPER];
NAME: name


1022 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b4
QSMONBTS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS:0,REQATTL=TCH-
DROR&SDCCHDROR&IMMASSFAIR&ASSFAIR&CLSETFAIR&TCHLOSR&SDC-
CHLOSR&HANDROR&HANFAIR&SUPPER;
GET QSMONBTS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS GET
QSMONBTS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
QSMONBTS object class.
TCHDROR: tchDroRate
SDCCHDROR: sdcchDropRate
IMMASSFAIR: immediateAssignmentFailureRate
ASSFAIR: assignmentFailureRate
CLSETFAIR: callSetupFailureRate
TCHLOSR: tchLossRate
SDCCHLOSR: sdcchLossRate
HANDROR: handoverDropRate
HANFAIR: handoverFailureRate
SUPPER: supper
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already
equipped.
GET QSMONBTS
BASICS
NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0;


A30808-X3247-M230-6-7619

1023
CML:BSC QSMONBTS
Id:0900d805800d42b4
Long Names:
NAME Addres of the managed object
TCHDROR tCHDropRate
SDCCHDROR sDCCHDropRate
IMMASSFAIR immediateAssignmentFailureRate
ASSFAIR assignmentFailureRate
CLSETFAIR callSetupFailureRate
TCHLOSR tCHLossRate
SDCCHLOSR sDCCHLossRate
HANDROR handoverDropRate
HANFAIR handoverFailureRate
SUPPER supervisionPeriod
System Responses:
See GET QSMONBTS
Application Guidelines:
See GET QSMONBTS
Example of Command Execution:
See GET QSMONBTS
GET QSMONBTS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS GET
QSMONBTS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command allows to display the administrative, operational, usage state and all the
status attributes of a specified object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
GET QSMONBTS STAT NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0;


1024 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b4
QSMONBTS
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get QSMONBTS STAT:NAME=BTSM:0/BTS:0/QSMONBTS:0;
GETCURRENTVALUE QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS GET-
CURRENTVALUE QSMONBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to have a snapshot of the QoS BTS current status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVALUE
QSMONBTS
NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
It is not possible to perform the command.
UNSUCCESSFUL_INVALID_STATUS
Qsmon is off_duty.


A30808-X3247-M230-6-7619

1025
CML:BSC QSMONBTS
Id:0900d805800d42b4
Example of Command Execution:
GetCurrentValues QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS:0;
LOCK QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS LOCK
QSMONBTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The administrative state Locked will survive at the Full Init (and consequently to the
load database).
Example of Command Execution:
Lock QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS:0;
LOCK QSMONBTS NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state


1026 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b4
QSMONBTS
SET QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS SET
QSMONBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the QSMONBTS object class.
Long Names:
NAME Addres of the managed object
TCHDROR tCHDropRate
SDCCHDROR sDCCHDropRate
IMMASSFAIR immediateAssignmentFailureRate
ASSFAIR assignmentFailureRate
CLSETFAIR callSetupFailureRate
TCHLOSR tCHLossRate
SDCCHLOSR sDCCHLossRate
HANDROR handoverDropRate
HANFAIR handoverFailureRate
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
SET QSMONBTS NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0 [,TCH-
DROR=] [,SDCCHDROR=] [,IMMASSFAIR=] [,ASSFAIR=]
[,CLSETFAIR=] [,TCHLOSR=] [,SDCCHLOSR=] [,HAN-
DROR=] [,HANFAIR=] [,SUPPER=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object is not already created.
UNSUCCESSFUL_WRONG_LIST_OF_QOSINDICATOR
At least one attribute "QoS Indicator" must be present.
UNSUCCESSFUL_THRESHOLD_SET_NOTEQUIPPED
The QSTHRS object instance must be already equipped.


A30808-X3247-M230-6-7619

1027
CML:BSC QSMONBTS
Id:0900d805800d42b4
Application Guidelines:
None.
Example of Command Execution:
Set QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS=0, TCHDROR=NULL, SDCCH-
DROR=NULL, IMMASSFAIR=NULL, ASSFAIR=NULL, CLSETFAIR=NULL,
TCHLOSR=NULL, SDCCHLOSR=NULL, HANDROR=NULL, HANFAIR=NULL, SUP-
PER=MINUTES_5;;
UNLOCK QSMONBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS QSMONBTS
UNLOCK QSMONBTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNSUCCESSFUL_INVALID_STATUS
The administrative state is not LOCKED.
UNLOCK QSMONBTS NAME=BTSM:0..199/BTS:0..23/QSMONBTS:0..0;
ALREADY_IN_TARGET_STATE
The selected object is in administrative state
"Unlocked".
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.


1028 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b4
QSMONBTS
Example of Command Execution:
Unlock QSMONBTS:NAME=BTSM:0/BTS:0/QSMONBTS:0;


A30808-X3247-M230-6-7619

1029
CML:BSC QSMONBTSCO
Id:0900d805800d42b7
QSMONBTSCO
The Quality of Service Monitor BTS Complex object class is located in the BSC.
It's always equipped and it doesn't foresee the handling of the states or any specific noti-
fications
GETINFO QSMONBTSCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONBTSCO GETINFO QSMON-
BTSCO
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of BTSMONITOR present into a QSMON-
BTSCO (Quality of Service Monitor for BTS complex).
For each QSMONBTS equipped:
the State and Status information (Administrative, Operational, Availability)
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT QSMONBTSCO: <QSMONBTSCO ID>
11:41:14 22/03/2001
BTSMONITOR: 3-5-0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: DISABLED
AVAILABILITY STATUS: OFF_DUTY
BTSMONITOR: 13-15-0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
GETINFO QSMON-
BTSCO
NAME=QSMONBTSCO:0..0;


1030 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42b7
QSMONBTSCO
BTSMONITOR: 13-15-0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
END OF REPORT
- Operation Failed
GETINFO QSMONBTSCO NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack QSMONBTSCO:
name = QSMONBTSCO:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
The QSMONBTSCO is always equipped, but the information about its monitored objects
is present only for QSMONBTSs equipped.
Example of Command Execution:
Getinfo QSMONBTSCO:NAME=QSMONBTSCO:0;
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


A30808-X3247-M230-6-7619

1031
CML:BSC QSMONGPRS
Id:0900d805800d42ba
QSMONGPRS
The QSMONGPRS object is used to monitor the Quality of Service indicator.
CREATE QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS CREATE QSMONGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the QSMONGPRS object class. .
Long Names:
NAME Addres of the managed object
TBFDROR tBFDropRate
TBFREAFAIR tBFReasignmentFailureRate
TBFLOSR tBFLossRate
NTWCONCRESFAIR networkControlledCellReselFailureRate
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE QSMONGPRS NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0 [,TBFDROR=] [,TBFREAFAIR=] [,TBFLOSR=]
[,NTWCONCRESFAIR=] [,SUPPER=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_WRONG_LIST_OF_QOSINDICATOR
At least one attribute "QoS Indicator" must be present.
UNSUCCESSFUL_THRESHOLD_SET_NOTEQUIPPED
The QSTHRS object instance must be already equipped.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED


1032 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ba
QSMONGPRS
Application Guidelines:
None.
Example of Command Execution:
Create QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS:0,
TBFDROR=NULL, TBFREAFAIR=NULL, TBFLOSR=NULL, NTWCONCRES-
FAIR=NULL, SUPPER=MINUTES_5;
DELETE QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS DELETE QSMONGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the QSMONGPRS object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS:0;
The PTPPKF object instance must be already equipped.
DELETE QSMONGPRS NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a QSMONGPRS, the relative object instance must be in
LOCKED state.


A30808-X3247-M230-6-7619

1033
CML:BSC QSMONGPRS
Id:0900d805800d42ba
GET QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS GET QSMONGPRS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the QSMON-
GPRS object class.
Long Names:
NAME Addres of the managed object
TBFDROR tBFDropRate
TBFREAFAIR tBFReasignmentFailureRate
TBFLOSR tBFLossRate
NTWCONCRESFAIR networkControlledCellReselFailureRate
SUPPER supervisionPeriod
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
GET QSMONGPRS NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0 [,REQATTL= TBFDROR ,TBFREAFAIR
,TBFLOSR ,NTWCONCRESFAIR ,SUPPER];
NAME: name
TBFDROR: tbfDroRate
TBFREAFAIR: tbfReassignmentFailureRate
TBFLOSR: tbfLossRate
NTWCONCRESFAIR: NetworkControlledCellReselec-
tionFailureRate
SUPPER: supper
UNSUCCESSFUL_OBJECT_NOTEQUIPPE
D
The object instance must be
already equipped.


1034 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ba
QSMONGPRS
Application Guidelines:
None.
Example of Command Execution:
Get QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONG-
PRS:0,REQATTL=TBFDROR&TBFREAFAIR&TBFLOSR&NTWCONCRES-
FAIR&SUPPER;
GET QSMONGPRS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS GET QSMONGPRS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the QSMON-
GPRS object class.
Long Names:
NAME Addres of the managed object
TBFDROR tBFDropRate
TBFREAFAIR tBFReasignmentFailureRate
TBFLOSR tBFLossRate
NTWCONCRESFAIR networkControlledCellReselFailureRate
SUPPER supervisionPeriod
System Responses:
See GET QSMONGPRS
Application Guidelines:
See GET QSMONGPRS
Example of Command Execution:
See GET QSMONGPRS
GET QSMONGPRS
BASICS
NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0;


A30808-X3247-M230-6-7619

1035
CML:BSC QSMONGPRS
Id:0900d805800d42ba
GET QSMONGPRS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS GET QSMONGPRS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command allows to display the administrative, operational, usage state and all the
status attributes of a specified object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get QSMONGPRS STAT:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS:0;
GETCURRENTVALUE QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS GETCURRENTVALUE QSMONGPRS
Applicability:
Phase 2.
GET QSMONGPRS
STAT
NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVALUE
QSMONGPRS
NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0;


1036 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ba
QSMONGPRS
Visibility level: 0.
Command Description:
This command is used to have a snapshot of the QoS GPRS current status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
Example of Command Execution:
GetCurrentValues QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS:0;
LOCK QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS LOCK QSMONGPRS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked". The
command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
It is not possible to perform the command.
UNSUCCESSFUL_INVALID_STATUS
Qsmon is off_duty.
LOCK QSMONGPRS NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0;


A30808-X3247-M230-6-7619

1037
CML:BSC QSMONGPRS
Id:0900d805800d42ba
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The administrative state Locked will survive at the Full Init (and consequently to the
load database).
Example of Command Execution:
Lock QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS:0;
SET QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS SET QSMONGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the QSMONGPRS object class.
Long Names:
NAME Addres of the managed object
TBFDROR tBFDropRate
TBFREAFAIR tBFReasignmentFailureRate
TBFLOSR tBFLossRate
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of
the system state
SET QSMONGPRS NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0 [,TBFDROR=] [,TBFREAFAIR=] [,TBFLOSR=]
[,NTWCONCRESFAIR=] [,SUPPER=];


1038 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ba
QSMONGPRS
NTWCONCRESFAIR networkControlledCellReselFailureRate
SUPPER supervisionPeriod
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS=0,
TBFDROR=NULL, TBFREAFAIR=NULL, TBFLOSR=NULL, NTWCONCRES-
FAIR=NULL, SUPPER=MINUTES_5;
UNLOCK QSMONGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS PTPPKF QSMONG-
PRS UNLOCK QSMONGPRS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object is not already created.
UNSUCCESSFUL_WRONG_LIST_OF_QOSINDICATOR
At least one attribute "QoS Indicator" must be present.
UNSUCCESSFUL_THRESHOLD_SET_NOTEQUIPPED
The QSTHRS object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The administrative state is not LOCKED.
UNLOCK QSMONG-
PRS
NAME=BTSM:0..199/BTS:0..23/PTPPKF:0..0/QSMONG-
PRS:0..0;


A30808-X3247-M230-6-7619

1039
CML:BSC QSMONGPRS
Id:0900d805800d42ba
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock QSMONGPRS:NAME=BTSM:0/BTS:0/PTPPKF:0/QSMONGPRS:0;
ALREADY_IN_TARGET_STATE
The selected object is in administrative state
"Unlocked".
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.


1040 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42bd
QSMONGPRSCO
QSMONGPRSCO
The Quality of Service Monitor GPRS Complex object class is located in the BSC.
It's always equipped and it doesn't foresee the handling of the states or any specific noti-
fications
GETINFO QSMONGPRSCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSMONGPRSCO GETINFO
QSMONGPRSCO
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of GPRSMONITOR present into a QSMONG-
PRSCO (Quality of Service Monitor for GPRS complex).
For each QSMONGPRS equipped:
the State and Status information (Administrative, Operational, Availability)
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT QSMONGPRSCO: <QSMONGPRSCO ID>
11:41:14 22/03/2001
GPRSMONITOR: 3-5-0-0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: OFF_DUTY
GPRSMONITOR: 199-15-0-0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
GETINFO QSMONGPR-
SCO
NAME=QSMONGPRSCO:0..0;


A30808-X3247-M230-6-7619

1041
CML:BSC QSMONGPRSCO
Id:0900d805800d42bd
GPRSMONITOR: 13-15-0-0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
END OF REPORT
- Operation Failed
GETINFO QSMONGPRSCO NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack QSMONGPRSCO:
name = QSMONGPRSCO:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
The QSMONGPRSCO is always equipped, but the information about its monitored
objects is present only for QSMONGPRSs equipped.
Example of Command Execution:
Getinfo QSMONGPRSCO:NAME=QSMONGPRSCO:0;
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.


1042 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d466d
QSTHRS
QSTHRS
The Quality of Service Threshold set object (QSTHRS) is responsible to keep the
threshold information; each threshold parameter contains three different threshold sets
and each one of them is made of six values (Number of samples, Threshold Major High,
Threshold Major Low, Threshold Minor High, Threshold Minor Low).
CREATE QSTHRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSTHRS CREATE QSTHRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the QSTHRS object class. .
Long Names:
NAME Addres of the managed object
THRS<n> thresholdSet<n>
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE QSTHRS NAME=QSTHRS:0..49 ,THRS<n>=;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
All "NumSamples" values together must fulfil the following inequal-
ities:
NumSamples#1 <0.9 x NumSamples#2-1
Numsamples#2 <0.9 x NumSamples#3-1
TshMajorHigh (TshMinorHigh) must not be below TshMajorLow
(TshMinorLow)


A30808-X3247-M230-6-7619

1043
CML:BSC QSTHRS
Id:0900d805800d466d
Application Guidelines:
1. If both threshold (TshMajorHigh/TshMajorLow and/or TsMinorHigh/TshMinorLow)
are set to 0, then the respective major and/or minor alarm is inactive. The following
examples would clarify the behaviour:
TshMinorLow=0 TshMinorHigh=0, TshMajorLow=0, TshMajorHigh=10 ----> Minor
Alarms are deactivated and Major Alarms are activated;
TshMinorLow=0 TshMinorHigh=10, TshMajorLow=0, TshMajorHigh=0 ----> Minor
Alarms are activated and Major Alarms are deactivated;
TshMinorLow=0 TshMinorHigh=0, TshMajorLow=0, TshMajorHigh=0 ----> both
Minor and Major Alarms are deactivated;
This implicitly means that the TshMinorHigh/TshMajorHigh active range is 1..100 (0 is
used only for deactivation) while TshMinorLow/TshMajorLow range is 0..100 (0 can be
used both for alarm thresholds as for deactivation depending on TshMinorHigh/TshMa-
jorHigh value).
Example of Command Execution:
Create QSTHRS:NAME=QSTHRS=0, THRS1=5-10-10-10-10-2, THRS2=5-10-10-10-
10-2,THRS3=5-10-10-10-10-2;
DELETE QSTHRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSTHRS DELETE QSTHRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the QSTHRS object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
DELETE QSTHRS NAME=QSTHRS:0..49;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED


1044 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d466d
QSTHRS
Application Guidelines:
None.
Example of Command Execution:
Delete QSTHRS:NAME=QSTHRS:0;
GET QSTHRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSTHRS GET QSTHRS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the QSTHRS
object class.
Long Names:
NAME Addres of the managed object
THRS<n> thresholdSet<n>
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
The QoS Monitor object instance associated to the QSTHRS object
instance must be previously deleted.
GET QSTHRS NAME=QSTHRS:0..49 [,REQATTL= THRS<n>];
NAME: name
THRS1: thresholdSet1
THRS2: thresholdSet2
THRS3: thresholdSet3
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already
equipped.


A30808-X3247-M230-6-7619

1045
CML:BSC QSTHRS
Id:0900d805800d466d
Example of Command Execution:
Get QSTHRS:NAME=QSTHRS:0,REQATTL=THRS1&THRS2&THRS3;
GET QSTHRS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSTHRS GET QSTHRS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the QSTHRS
object class.
Long Names:
NAME Addres of the managed object
THRS<n> thresholdSet<n>
System Responses:
See GET QSTHRS
Application Guidelines:
See GET QSTHRS
Example of Command Execution:
See GET QSTHRS
GETINFO QSTHRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSTHRS GETINFO QSTHRS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following information:
GET QSTHRS BASICS NAME=QSTHRS:0..49;
GETINFO QSTHRS NAME=QSTHRS:0..49;


1046 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d466d
QSTHRS
1. QSMONBTS: it's a list of max 400 BTSMONITOR entry consisting in:
BTSMONITOR identifier
BTS indicators (max 9); possible values are:
tCHDropRate
sDCCHDropRate
immediateAssignmentFailureRate
assignmentFailureRate
callSetupFailureRate
tCHLossRatesDCCHLossRate
handoverDropRate
handoverFailureRate
2. QSMONGPRS: it's a list of max 400 GPRSMONITOR entry consisting in:
GPRSMONITOR identifier
GPRS indicators (max 5); possible values are:
tBFDropRate
tBFAssignmentFailureRate
tBFReassignmentFailureRate
tBFLossRate
networkControlledCellReselectionFailureRate
3. QSMONBSC: a BSC monitor containing:
monitor indicators (max 2); possible values are:
tDPCProcessorLoad
pCUPProcessorLoad
( I ) If the LMT is connected in remote mode, it is not possible to execute this command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO REPORT QSTHRS: <QSTHRS ID>
11:41:14 22/03/2001
QSMONBTS LIST (btsm#-bts#-0 fixed):
BTSMONITOR: 3-5-0
tCHDropRate
assignmentFailureRate
BTSMONITOR: 30-10-0
tCHDropRate
BTSMONITOR: 9-5-0


A30808-X3247-M230-6-7619

1047
CML:BSC QSTHRS
Id:0900d805800d466d
tCHDropRate
assignmentFailureRate
handoverDropRate
BTSMONITOR: 7-5-0
tCHDropRate
assignmentFailureRate
QSMONGPRS LIST: (btsm#-bts#-0-0)
GPRSMONITOR: 3-5-0-0
networkControlledCellReselectionFailureRate
tBFDropRate
tBFAssignmentFailureRate
tBFReassignmentFailureRate
tBFLossRate
...;
GPRSMONITOR: 3-5-0-0
tBFReassignmentFailureRate
tBFDropRate
GPRSMONITOR: 3-5-0-0
tBFLossRate
QSMONBSC LIST:
tDPCProcessorLoad
pCUProcessorLoad
END OF REPORT
- Operation Failed
GETINFO QSTHRS NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack QSTHRS:
name = QSTHRS:0
nackCause = <nack cause>


1048 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d466d
QSTHRS
NACK CAUSES:
Application Guidelines:
The information about QSMONBTSs, QSMONGPRSs and QSMONBSC are present
only for the equipped.
Example of Command Execution:
Getinfo QSTHRS:NAME=QSTHRS:0;
SET QSTHRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL QSTHRS SET QSTHRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the QSTHRS object class.
Long Names:
NAME Addres of the managed object
THRS<n> thresholdSet<n>
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
SET QSTHRS NAME=QSTHRS:0..49 [,THRS<n>=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The instance of the object must be already created.


A30808-X3247-M230-6-7619

1049
CML:BSC QSTHRS
Id:0900d805800d466d
Application Guidelines:
After a SET:QSTHRS command QoS data shall not be recalculated. All related QoS
Alarms are reset.
Example of Command Execution:
Set QSTHRS:NAME=QSTHRS=0, THRS1=5-10-10-10-10-2, THRS2=5-10-10-10-10-
2,THRS3=5-10-10-10-10-2;
UNSUCCESSFUL_INVALID_ATTRIBUTES
All "NumSamples" values together must fulfil the following ine-
qualities:
NumSamples#1 <0.9 x NumSamples#2-1
Numsamples#2 <0.9 x NumSamples#3-1
TshMajorHigh (TshMinorHigh) must not be below TshMajorLow
(TshMinorLow)


1050 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c3
REMINV
REMINV
The REMINV (Remote Inventory) object manages the RC user Inventory Data File (IDF)
request and all its messages flows.
ALIGN REMINV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV ALIGN REMINV
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs an upload of the NE IDF from the specified NE instance to the
BSC disk to align the "central_bsc" file.
Long Names:
NAME Addres of the managed object
NE networkEntity
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
ALIGN REMINV NAME=REMINV:0..0 ,NE=;
NAME: name
ADMINISTRATIVE_STATE_INVALID
The command is received during an invalid REMINV state (Init BSC
and/or Init NE states).
UPLOAD_ALREADY_IN_PROGRESS
The command is received while another one is in progress.
RESOURCE_NOT_AVAILABLE
The command is received when the involved NE is not reachable
(BSC-NE link is down or BTSM is not in unlocked-enable and not in
initializing state status).
UNSUCCESSFUL_STATUS_BIT_NOT_INITIALIZED
The command is occurred when Procedural Status attribute of
REMINV object is set at NOT_INITIALIZED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

1051
CML:BSC REMINV
Id:0900d805800d42c3
Application Guidelines:
In order to perform the ALIGN REMINV command, the administrative state of the
REMINV object must be LOCKED.
Example of Command Execution:
Align REMINV:NAME=REMINV:0,NE=btse((BTSE-1));
Align REMINV:NAME=REMINV:0,NE=traue((TRAUE-1));
DNLIDFD REMINV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV DNLIDFD REMINV
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command executes the downloading of the nob-RIU (not on board-Remote
Inventory Unit) file (its name must be mandatory BSC_NRIU) from the LMT hard-disk to
the BSC disk.
Long Names:
NAME Addres of the managed object
SRCDIR sourceDir
System Responses:
- Operation Completed
The LMT notifies the percentage of the file downloaded in steps of 5% (on the "info line")
and the successful completion of the procedure.
- Operation Failed
The object instance must be already equipped.
DNLIDFD REMINV NAME=REMINV:0..0 [,SRCDIR=];
Possible errors, causing the procedure to abort, notified by the LMT are:
File Not Found
Message Out Of Sequence
Aborted By User
Time Out Expired
Aborted By Network Element
File Too Long For Zero Window Size


1052 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c3
REMINV
Application Guidelines:
1. The BSC_NRIU file must be created by means of the IDF editor tool.
2. If a BSC_NRIU file was already present before this command execution, it will be
overwritten.
3. This command can be performed with REMINV object both in LOCKED and
UNLOCKED administrative state.
4. The directory ../Idf/Dnload, present in the LMT installation, is used for the operation.
Example of Command Execution:
DNLIDFD REMINV:NAME=REMINV:0,SRCDIR="C:\Siemens\ LMT271_10\
Idf\Dnload";
GET REMINV STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV GET REMINV STAT
Applicability:
Phase 2.
Disk Access Error
User Abort Refused
Internal SW Error
Segment Out Of Sequence
Last Segment Expected
Disk Write Error
Disk Error
Crosscopy In Progress
Wrong Destination Path
Possible errors, causing the procedure to abort, notified by the download task on
MPCC and displayed by the LMT are:
String Too Long a non-terminated string is present in a message
field;
Invalid Parameter a message parameter is syntactically incorrect or
two message parameters are conflicting;
RTE Failure the download task could not obtain an Operating
System service;
File System Failed the download task could not obtain a File System
service;
GET REMINV STAT NAME=REMINV:0..0;


A30808-X3247-M230-6-7619

1053
CML:BSC REMINV
Id:0900d805800d42c3
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
REMINV object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
The administrative state is handled via LOCK/UNLOCK REMINV commands.
The procedural status is handled only at initialization time. The only admitted value is
NOT_INITIALIZED, that is also the default initial value and is reset at the end of the
initialization phase.
Example of Command Execution:
Get REMINV STAT:NAME=REMINV:0;
USER NAME:
COMMAND:
SW RELEASE:
COMMAND RESULT:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.


1054 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c3
REMINV
LOCK REMINV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV LOCK REMINV
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set the REMINV object at the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state LOCKED will survive at the Full Init (and consequently to
the load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock REMINV:NAME=REMINV:0;
UNLOCK REMINV
LOCK REMINV NAME=REMINV:0..0;
USER NAME:
COMMAND:
SW RELEASE:
COMMAND RESULT:
ALREADY_IN_TARGET_STATE
The referenced object instance (REMINV:0) is in the administra-
tive state LOCKED.
UNLOCK REMINV NAME=REMINV:0..0;


A30808-X3247-M230-6-7619

1055
CML:BSC REMINV
Id:0900d805800d42c3
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV UNLOCK REMINV
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set REMINV object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock REMINV:NAME=REMINV:0;
UPLCIDF REMINV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV UPLCIDF REMINV
Applicability:
Phase 2.
Visibility level: 0.
USER NAME:
COMMAND:
SW RELEASE:
COMMAND RESULT:
ALREADY_IN_TARGET_STATE
The referenced object instance (REMINV:0) is in the admin-
istrative state UNLOCKED.
UPLCIDF REMINV NAME=REMINV:0..0 [,DESTDIR=] [,FILE=] ,OVERWRITE=;


1056 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c3
REMINV
Command Description:
This command allows the upload of the global IDF file.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
FILE file
OVERWRITE Overwrite
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The UPLCIDF command can be accepted only if the REMINV object is in
LOCKED/ENABLE administrative/operational state.
2. When the Upload is in progress, no other operator command on REMINV object can
be accepted.
3. The global IDF is built compressing together the local BSC IDF and the IDFs of all
the NEs that are created. These IDFs are made using the data present on BSC disk
Uploading File: REMIN6/SBS IDT.CPX
From Directory:
To: BSC.ZTD
On Directory:..\Idf\Upload
USER NAME:
COMMAND:
SW RELEASE:
COMMAND RESULT:
ADMINISTRATIVE_STATE_INVALID
The command is occurred when REMINV object is in INIT BSC and
or INIT NE state or in UNLOCKED state.
UNSUCCESSFUL_STATUS_BIT_NOT_INITIALIZED
The command is occurred when Procedural Status attribute of
REMINV object is set at NOT_INITIALIZED.
UPLOAD_ALREADY_IN_PROGRESS
The command is occurred when another UPLOAD procedure is in
progress.


A30808-X3247-M230-6-7619

1057
CML:BSC REMINV
Id:0900d805800d42c3
system at the time the UPLCIDF command is in progress.The file name must have
.zdt extension.
4. The directory ../Idf/Upload, present in the LMT installation, is used to load the
bsc.zdt file.
5. If remote inventory data from a BTSE or TRAU entity are aligned with the ALIGN
REMINV command, it is necessary to unlock and lock again the remote inventory to
have the data available for upload and the display.
Example of Command Execution:
UPLCIDF REMINV:NAME=REMINV:0,DESTDIR="c:\Siemens\Idf\Upload",
FILE="bsc_central.zdt",OVERWRITE=YES;
UPLLIDF REMINV
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT REMINV UPLLIDF REMINV
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command allows the upload of the local IDF file.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
FILE file
OVERWRITE Overwrite
System Responses:
- Operation Completed
UPLLIDF REMINV NAME=REMINV:0..0 [,DESTDIR=] [,FILE=] ,OVERWRITE=;
Uploading File: REMIN6/BSC IDT
From Directory:
To: BSC.IDT
On Directory:..\Idf\Upload
USER NAME:
COMMAND:
SW RELEASE:
COMMAND RESULT:


1058 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c3
REMINV
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The UPLLIDF command can be executed only if the REMINV object is in
LOCKED/ENABLE administrative/operational state.
2. When the Upload is in progress, no other operator command on REMINV object can
be accepted.
3. The file name (FILE parameter) must have .idt extension.
4. The directory ../Idf/Upload, present in the LMT installation, is used to load the bsc.idt
file.
Example of Command Execution:
UPLLIDF REMINV:NAME=REMINV:0,DESTDIR="c:\Siemens\Idf\Upload",
FILE="bsc_local.idt",OVERWRITE=YES;
ADMINISTRATIVE_STATE_INVALID
The command is occurred when REMINV object is in INIT BSC and
or INIT NE state or in UNLOCKED state.
UNSUCCESSFUL_STATUS_BIT_NOT_INITIALIZED
The command is occurred when Procedural Status attribute of
REMINV object is set at NOT_INITIALIZED.
UPLOAD_ALREADY_IN_PROGRESS
The command is occurred when another UPLOAD procedure is in
progress.


A30808-X3247-M230-6-7619

1059
CML:BSC RFLOOP
Id:0900d805800d42c6
RFLOOP
The RFLOOP object allows the operator to test the complete RF signal path of a BTSE
including the cabling and connectors and will thus significantly enhance the overall test
coverage.
CREATE RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP CREATE
RFLOOP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to create the RFLOOP object.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
ALTH alarmThreshold
MINCCNT minCallCount
MECNT measCount
RXLV rxLevel
AUTOREP autoReport
BANDOFHYS bandWidthOfHysteresis
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
CREATE RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0 [,START=]
[,STOP=] [,ALTH=] [,MINCCNT=] [,MECNT=] [,RXLV=]
[,AUTOREP=] [,BANDOFHYS=];
. OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED


1060 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c6
RFLOOP
Application Guidelines:
None.
Example of Command Execution:
Create RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0,START=1-1-2001,
STOP=2-2-2002,ALTH=30,MINCCNT=50,MECNT=200,RXLV=10,AUTOREP=TRUE,
BANDOFHYS=25;
DELETE RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP DELETE
RFLOOP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a RFLOOP instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
The superordinate object instances must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
DELETE RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a RFLOOP, the relative object instance must be in
LOCKED state.


A30808-X3247-M230-6-7619

1061
CML:BSC RFLOOP
Id:0900d805800d42c6
Example of Command Execution:
Delete RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0;
GET RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP GET
RFLOOP
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the values of the parameters selected by the operators
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
ALTH alarmThreshold
MINCCNT minCallCount
MECNT measCount
RXLV rxLevel
AUTOREP autoReport
BANDOFHYS bandWidthOfHysteresis
System Responses:
- Operation Completed
GET RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0 [,REQATTL=
START ,STOP ,ALTH ,MINCCNT ,MECNT ,RXLV
,AUTOREP ,BANDOFHYS];
NAME: name
START: startDate
STOP: stopDate
ALTH: alarmThreshold
MINCCNT: minCallCount
MECNT: measCount
RXLV: rxLevel
AUTOREP: autoReport


1062 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c6
RFLOOP
GET RFLOOP BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET RFLOOP BASICS
None.
Example of Command Execution:
Get RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0, REQATTL=START&STOP&ALTH&
MINCCNT&MECNT&RXLV&AUTOREP&BANDOFHYS;
GET RFLOOP BASICS
Get RFLOOP BASICS:NAME=BTSM:0/BTS:0/RFLOOP:0;
GET RFLOOP BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP GET
RFLOOP BASICS
BANDOFHYS: bandWidthOfHysteresis
NAME: name
START: startDate
STOP: stopDate
ALTH: alarmThreshold
MINCCNT: minCallCount
MECNT: measCount
RXLV: rxLevel
AUTOREP: autoReport
BANDOFHYS: bandWidthOfHysteresis
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET RFLOOP BASICS NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0;


A30808-X3247-M230-6-7619

1063
CML:BSC RFLOOP
Id:0900d805800d42c6
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the values of the parameters selected by the operators
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
ALTH alarmThreshold
MINCCNT minCallCount
MECNT measCount
RXLV rxLevel
AUTOREP autoReport
BANDOFHYS bandWidthOfHysteresis
System Responses:
See GET RFLOOP
Application Guidelines:
See GET RFLOOP
Example of Command Execution:
See GET RFLOOP
GET RFLOOP STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP GET
RFLOOP STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
RFLOOP object:
Administrative State (AST)
Operational State (OST)
GET RFLOOP STAT NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0;


1064 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c6
RFLOOP
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get RFLOOP STAT:NAME=BTSM:0/BTS:0/RFLOOP:0;
LOCK RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP LOCK
RFLOOP
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0;


A30808-X3247-M230-6-7619

1065
CML:BSC RFLOOP
Id:0900d805800d42c6
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0;
SET RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP SET
RFLOOP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the user to change the setting related to a RFLOOP object
previously created.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
ALTH alarmThreshold
MINCCNT minCallCount
MECNT measCount
RXLV rxLevel
ALREADY_IN_TARGET_STATE
The object instance is in administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0 [,START=]
[,STOP=] [,ALTH=] [,MINCCNT=] [,MECNT=] [,RXLV=]
[,AUTOREP=] [,BANDOFHYS=];


1066 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c6
RFLOOP
AUTOREP autoReport
BANDOFHYS bandWidthOfHysteresis
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0,START=1-1-2001,STOP=1-2-2001,
ALTH=25;
UNLOCK RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP UNLOCK
RFLOOP
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The superordinate object instances must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
UNLOCK RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0;


A30808-X3247-M230-6-7619

1067
CML:BSC RFLOOP
Id:0900d805800d42c6
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0;
UPLOADREQ RFLOOP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS RFLOOP UPLOA-
DREQ RFLOOP
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows the user to upload the files from the BSC disk to the LMT disk; the
destination directory, the file name and the file overwriting (or not) must be defined by
the user.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UPLOADREQ RFLOOP NAME=BTSM:0..199/BTS:0..23/RFLOOP:0..0 ,DESTDIR=
,OVERWRITE=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS


1068 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c6
RFLOOP
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
Uploadreq RFLOOP:NAME=BTSM:0/BTS:0/RFLOOP:0,DESTDIR="C:\Siemens",
FILE="File_name",OVERWRITE=YES;
Before launching this command, the relative object instance must not
be in LOCKED state.
According to the configured stopDate field value, measurement data
collection is finished (i.e. the stopDate has been reached): the upload
cannot be executed since measures are not present in the BTS
equipment.


A30808-X3247-M230-6-7619

1069
CML:BSC RNSVLIP
Id:0900d805800d42c9
RNSVLIP
The RNSVLIP object represents the remote NSVLIP.
In case of static configuration it is necessary to create a RNSVLIP for each remote
endpoint to configure, specifying each single meshed connection with local endpoint to
allow (by selecting all the connections it is possible to realize the fully meshed connec-
tion even in static configuration). The system will automatically create an NS-VC object
for each connection specified in the attribute list for the remote endpoint.
In case of dynamic configuration it is not allowed to create RNSVLIP object.
The RNSVLIP object is subordinate of PCU class. It is possible to create up to 16
RNSVLIP instance per PCU.
CREATE RNSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU RNSVLIP CREATE RNSVLIP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the RNSVLIP object class.
Long Names:
NAME Addres of the managed object
RMTIPEP remoteIPEndpoint
WEID weightData
WEIS weigthSignalling
NSCONN ntwServiceConnection
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE RNSVLIP NAME=PCU:0..11/RNSVLIP:0..15 ,RMTIPEP= [,WEID=]
[,WEIS=] ,NSCONN=;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED


1070 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c9
RNSVLIP
Application Guidelines:
None.
Example of Command Execution:
Create RNSVLIP:NAME=PCU:0/RNSVLIP:2:RMTIPEP=aaa-1024, WEID=10,
WEIS=10,NSCONN=All;
DELETE RNSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU RNSVLIP DELETE RNSVLIP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the RNSVLIP object class. The
object to be deleted shall be previously locked.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
The relavant PCU object instances must be already equipped.
The NSCONnn cannot be referenced in NSCON list if the related
NSVLIP is not equipped.
UNSUCCESSFUL_INVALID_COMMAND
No RNSVLIP can be created if the superordinate PCU has the
GBSNS set to a value different from FR.
No RNSVLIP can be created if the superordinate PCU has the
attribute TYPOFNSVCCONF set to DYNAMIC.
UNSUCCESSFUL_INVALID_ATTRIBUTE
The IPAddress field of RMTIPEP must be valid IP address.
More instances of RNSVLIP cannot have the same Udp port.
DELETE RNSVLIP NAME=PCU:0..11/RNSVLIP:0..15;


A30808-X3247-M230-6-7619

1071
CML:BSC RNSVLIP
Id:0900d805800d42c9
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete RNSVLIP:NAME=PCU:0/RNSVLIP:2;
GET RNSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU RNSVLIP GET RNSVLIP
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the RNSVLIP
object class.
Long Names:
NAME Addres of the managed object
RMTIPEP remoteIPEndpoint
WEID weightData
WEIS weigthSignalling
NSCONN ntwServiceConnection
System Responses:
- Operation Completed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET RNSVLIP NAME=PCU:0..11/RNSVLIP:0..15 [,REQATTL= RMTIPEP
,WEID ,WEIS ,NSCONN];
RMTIPEP: remoteIPEndpoint
WEID: weigthData
WEIS: weigthSignalling
NSCONN ntwServiceConnections


1072 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c9
RNSVLIP
GET RNSVLIP BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET RNSVLIP BASICS
None.
Example of Command Execution:
Get RNSVLIP: NAME=PCU:0/RNSVLIP:2,REQATTL=RMTI-
PEP&WEID&WEIS&NSCONN;
GET RNSVLIP BASICS
Get RNSVLIP BASICS: NAME=PCU:0/RNSVLIP:2,REQATTL=RMTI-
PEP&WEID&WEIS&NSCONN;
GET RNSVLIP BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU RNSVLIP GET RNSVLIP
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the RNSVLIP
object class.
RMTIPEP: remoteIPEndpoint
WEID: weigthData
WEIS: weigthSignalling
NSCONN ntwServiceConnections
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET RNSVLIP BASICS NAME=PCU:0..11/RNSVLIP:0..15;


A30808-X3247-M230-6-7619

1073
CML:BSC RNSVLIP
Id:0900d805800d42c9
Long Names:
NAME Addres of the managed object
RMTIPEP remoteIPEndpoint
WEID weightData
WEIS weigthSignalling
NSCONN ntwServiceConnection
System Responses:
See GET RNSVLIP
Application Guidelines:
See GET RNSVLIP
Example of Command Execution:
See GET RNSVLIP
SET RNSVLIP
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCU RNSVLIP SET RNSVLIP
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the RNSVLIP parameters.
Long Names:
NAME Addres of the managed object
RMTIPEP remoteIPEndpoint
WEID weightData
WEIS weigthSignalling
NSCONN ntwServiceConnection
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
SET RNSVLIP NAME=PCU:0..11/RNSVLIP:0..15 [,RMTIPEP=] [,WEID=]
[,WEIS=] [,NSCONN=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


1074 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42c9
RNSVLIP
Application Guidelines:
None.
Example of Command Execution:
Set RNSVLIP:NAME=PCU:0/RNSVLIP:2:RMTIPEP=aaa-1024, WEID=10,
WEIS=10,NSCONN=All;
The instance of the object must be already created in order to
perform the command.
SUPERORDINATE_NOTEQUIPPED
The NSCONnn cannot be referenced in NSCON list if the related
NSVLIP is not equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The IPAddress field of RMTIPEP must be valid IP address.
More instances of RNSVLIP cannot have the same Udp port.


A30808-X3247-M230-6-7619

1075
CML:BSC RSUDB
Id:0900d805800d42cd
RSUDB
The RSUDB (Replaceable Software Unit DataBase) represents an instance of a
managed object class identifying database files.
20 instances for this object are allowed.
All related commands (except CREATE RSUDB) consist of two fields but only one can
be used (NAME or USER LABEL DB).
CREATE RSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB CREATE RSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to execute the download of a database file on BSC disk.
Long Names:
IDRSUDB Addres of the managed object
ULAB userLabel
SRCPATH relatedFiles
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
CREATE RSUDB ULAB= ,SRCPATH=;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
No download in progress with this transfer identifier.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
OBJECT_ALREADY_IN_USE


1076 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42cd
RSUDB
Application Guidelines:
1. The command is performed if the Related Database file is present on LMT hard-disk.
2. The creation of a RSUDB instance implies the automatic creation of the related
BSCESUDB.
Example of Command Execution:
Create RSUDB:ULAB="user_label",SRCPATH="D:\BR61\BSC\hb010140\Dbfile.dba";
DELETE RSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB DELETE RSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs a deletion of a RSUDB object.
The command clashes with another one already in progress.
INVALID_PARAMETER_NCK
The file name is too long (a maximum of 14 characters is admitted).
The object address is incorrect.
The userLabel attribute (ULAB) already used for another RSUDB.
The file related to the new object is already used for another RSU
object.
The object already exists but with different attributes.
NO_INSTANCE_FREE
The maximum number of ESUDB instances is already created.
PROCESSING_ERROR_NCK
The object address is not available.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
DUPLICATED_OBJECT
The involved object instance is already present.
DUPLICATED_OBJECT_RSU_DISABLED
The involved object instance already exists but a recovery download
can be performed.
DELETE RSUDB NAME=RSUDB:0..19 [,IDRSUDB=];


A30808-X3247-M230-6-7619

1077
CML:BSC RSUDB
Id:0900d805800d42cd
Long Names:
NAME Addres of the managed object
IDRSUDB identifierRSUDB
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If RSUDB instance is related to a BSCESUDB pointed by backupESU BSCOSUDB
attribute or runningESU BSCOSUDB attribute or newESU BSCOSUDB attribute or
fallbackESU BSCOSUDB attribute, then the deletion is not allowed.
2. The deletion of RSUDB object implies the automatic deletion of the related
BSCESUDB object.
Example of Command Execution:
Delete RSUDB:NAME=RSUDB:0;
Delete RSUDB:IDRSUDB="userLabel";
GET RSUDB
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
ESU_OBJ_POINTED_BY_OSU_ATTR
The related ESUDB object can not be deleted (it is pointed by one of
the OSUDB attributes).
GET RSUDB IDRSUDB= [,REQATTL= ULAB ,RELF ,DBVER];


1078 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42cd
RSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB GET RSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the different attributes of RSUDB objects.
Long Names:
IDRSUDB Addres of the managed object
IDRSUDB identifierRSUDB
ULAB userLabel
RELF relatedFiles
DBVER dbVersion
System Responses:
- Operation Completed
GET RSUDB BASICS
- Operation Failed
NACK CAUSES:
ULAB
:
userLabel
RELF
:
relatedFiles
DBVER: dataBaseVersion
ULAB: userLabel
RELF: relatedFiles
DBVER: dataBaseVersion
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND


A30808-X3247-M230-6-7619

1079
CML:BSC RSUDB
Id:0900d805800d42cd
Application Guidelines:
If a GET RSUDB command is issued with a wrong USER LABEL DB in the IDRSUDB
attribute, the field 'Object Instance' of the LMT Message Browser might include a free
RSUDB instance, rather than being 'n.a.'.
GET RSUDB BASICS
None.
Example of Command Execution:
Get RSUDB:NAME=RSUDB:0,REQATTL=ULAB&RELF&DBVER;
Get RSUDB:IDRSUDB="16_08",REQATTL=ULAB&RELF&DBVER;
GET RSUDB BASICS
Get RSUDB BASICS:NAME=RSUDB:0;
Get RSUDB BASICS:IDRSUDB="userLabel";
GET RSUDB BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB GET RSUDB
BASICS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the different attributes of RSUDB objects.
Long Names:
IDRSUDB Addres of the managed object
ULAB userLabel
RELF relatedFiles
DBVER dbVersion
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
NO_INSTANCE_FREE
If the command is a GET RSUDB object instance.
GET RSUDB BASICS ;


1080 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42cd
RSUDB
System Responses:
See GET RSUDB
Application Guidelines:
See GET RSUDB
Example of Command Execution:
See GET RSUDB
GET RSUDB STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB GET RSUDB
STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
RSUDB object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
IDRSUDB Addres of the managed object
IDRSUDB identifierRSUDB
System Responses:
- Operation Completed
Refer to command description.
- Operation Failed
NACK CAUSES:
GET RSUDB STAT IDRSUDB=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY


A30808-X3247-M230-6-7619

1081
CML:BSC RSUDB
Id:0900d805800d42cd
Application Guidelines:
None.
Example of Command Execution:
Get RSUDB STAT:NAME=RSUDB:0;
Get RSUDB STAT:IDRSUDB="userLabel";
SET RSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB SET RSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs a change value of userLabel RSUDB attribute (ULAB).
Long Names:
NAME Addres of the managed object
IDRSUDB identifierRSUDB
ULAB userLabel
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
The message occurs when the Status Handler task is performing the
maximum number of commands.
SET RSUDB NAME=RSUDB:0..19 [,IDRSUDB=] ,ULAB=;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INVALID_PARAMETER_NCK
The userLabel attribute (ULAB) already used for another RSUDB.


1082 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42cd
RSUDB
Application Guidelines:
This command is not performed if specific userLabel (ULAB) value is already present;
in this case the command is rejected.
Example of Command Execution:
Set RSUDB:NAME=RSUDB:0,ULAB="newUserLabel";
Set RSUDB:IDRSUDB="oldUserLabel",ULAB="newUserLabel";
UPLDFILE RSUDB
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUDB UPLDFILE
RSUDB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs an upload of the data base object file.
Long Names:
IDRSUDB Addres of the managed object
IDRSUDB identifierRSUDB
DESTDIR DestinationDir
OWR overWrite
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
UPLDFILE RSUDB IDRSUDB= ,DESTDIR= ,OWR=;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
No upload in progress with this transfer identifier.
NO_TASKS_AVAILABLE


A30808-X3247-M230-6-7619

1083
CML:BSC RSUDB
Id:0900d805800d42cd
Application Guidelines:
To perform this command RSUDB object must be present and no other operation on the
Database must be in progress.
Example of Command Execution:
Upldfile RSUDB:NAME=RSUDB:0,DESTDIR="D:\",OWR=YES;
Upldfile RSUDB:IDRSUDB="userLabel",DESTDIR="D:\",OWR=YES;
No free servers are available to perform the command.
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
INVALID_PARAMETER_NCK
The file type is not DATABASE.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
FILE_NOT_FOUND
The file to be transferred is not present.


1084 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d0
RSUEXE
RSUEXE
The RSUEXE (Replaceable Software Unit Executable) represents an instance of a
managed object class identifying executable and VAM files.
250 instances for this object are allowed.
All related commands (except CREATE RSUEXE) consist of two fields but only one can
be used (NAME or USER LABEL SWLH).
CREATE RSUEXE
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
CREATE RSUEXE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to perform the download of a single executable or VAM file on the
BSC disk.
Long Names:
IDRSUEXE Addres of the managed object
SRCPATH relatedFiles
ULABSWLH userLabelSwLoadHeader
HEADER header
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
CREATE RSUEXE SRCPATH= ,ULABSWLH= ,HEADER=;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
No download in progress with this transfer identifier.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
ABORT_BY_SYSTEM_NCK


A30808-X3247-M230-6-7619

1085
CML:BSC RSUEXE
Id:0900d805800d42d0
Application Guidelines:
The RSUEXE object instance can be created only if the related RSUSWLH object
instance has been already created and if the related executable file is present on the
LMT hard disk.
Example of Command Execution:
Create RSUEXE:SRCPATH="D:\BR61\BSC\hb010140\m10140.abs,
ULABSWLH="Load13", HEADER="Hb010022.swl";
An internal system abort is occurred.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INVALID_PARAMETER_NCK
The file name is too long (a maximum of 14 characters is admitted).
The object address is incorrect.
The RSUEXE Network Element attribute is different from the
correspondent RSUSWLH.
A creation of two RSUEXE Network Elements with the same software
version and processor type and belonging to the same RSUSWLH
has occurred.
A creation of two BSC RSUEXEs with the same processor type and
belonging to the same RSUSWLH has occurred.
The object already exists but with different attributes.
A RSUEXE with the same file name and belonging to the same
RSUSWLH is already created.
The file related to the new object is already used for another RSU
object.
NO_INSTANCE_FREE
The maximum number of RSUEXE instances is already created.
SW_LOAD_HEADER_NOT_FOUND_NCK
The RSUSWLH owning this RSUEXE is not existent.
PROCESSING_ERROR_NCK
The creation of the new object instance has failed.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
DUPLICATED_OBJECT
The involved object instance is already present.
DUPLICATED_OBJECT_RSU_DISABLED
The involved object instance already exists but a recovery download
can be performed.


1086 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d0
RSUEXE
DELETE RSUEXE
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
DELETE RSUEXE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs a deletion of the RSUEXE object.
Long Names:
NAME Addres of the managed object
IDRSUEXE identifierRSUEXE
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
DELETE RSUEXE NAME=RSUSWLH:0..59/RSUEXE:0..249 [,IDRSUEXE=];
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
ESU_OBJ_POINTED_BY_OSU_ATTR
The deletion of a RSUEXE belonging to a BSC ESUSW pointed by an
OSUSW attribute is allowed only if the RSUEXE is
DISABLED-FAILED. The deletion of a RSUEXE belonging to a NE
ESUSW pointed by backupESU attribute is allowed only if the
RSUEXE is DISABLED-FAILED.


A30808-X3247-M230-6-7619

1087
CML:BSC RSUEXE
Id:0900d805800d42d0
Application Guidelines:
1. The delete operation of a RSUEXE with related BSC ESUSW pointed by:
backupESU attribute
newESU attribute
fallbackESU attribute
runningESU attribute
is allowed only if the RSUEXE is DISABLED-FAILED.
2. The delete operation of a RSUEXE with related NE ESUSW pointed by backup
OSUSW attribute is allowed only if the RSUEXE is DISABLED-FAILED.
3. The deletion of RSUEXE object implies the deletion of all the RSUPCH objects con-
tained into it.
Example of Command Execution:
Delete RSUEXE:NAME=RSUSWLH:17/RSUEXE:1;
Delete RSUEXE:IDRSUEXE="userLabel"-PPXL-"Y10700.ABS";
GET RSUEXE
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
GET RSUEXE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve different attributes of the RSUEXE object.
Long Names:
IDRSUEXE Addres of the managed object
IDRSUEXE identifierRSUEXE
VER version
PROCTYP processorType
RELF relatedFiles
System Responses:
- Operation Completed
GET RSUEXE IDRSUEXE= [,REQATTL= VER ,PROCTYP ,RELF];
VER: version
PROCTYP: processorType


1088 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d0
RSUEXE
GET RSUEXE BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET RSUEXE BASICS
None.
Example of Command Execution:
GET RSUEXE:
NAME=RSUSWLH:1/RSUEXE:0,REQATTL=VER&PROCTYP&RELF;
GET RSUEXE:
IDRSUEXE="userLabel"-MPCC-"M10900.ABS",
REQATTL=VER&PROCTYP&RELF;
RELF
:
relatedFiles
VER: version
PROCTYP: processorType
RELF
:
relatedFiles
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
SW_LOAD_HEADER_NOT_FOUND_NCK
If the command is a GET RSUEXE object instance.
NO_INSTANCE_FREE
If the command is a GET RSUEXE object instance.


A30808-X3247-M230-6-7619

1089
CML:BSC RSUEXE
Id:0900d805800d42d0
GET RSUEXE BASICS
Get RSUEXE BASICS:NAME=RSUSWLH:9/RSUEXE:0;
Get RSUEXE BASICS:IDRSUEXE="userLabel"-MPCC-"M10800.ABS";
GET RSUEXE BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
GET RSUEXE BASICS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve different attributes of the RSUEXE object.
Long Names:
IDRSUEXE Addres of the managed object
VER version
PROCTYP processorType
RELF relatedFiles
System Responses:
See GET RSUEXE
Application Guidelines:
See GET RSUEXE
Example of Command Execution:
See GET RSUEXE
GET RSUEXE STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
GET RSUEXE STAT
Applicability:
Phase 2.
GET RSUEXE BASICS ;
GET RSUEXE STAT IDRSUEXE=;


1090 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d0
RSUEXE
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
RSUEXE object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
IDRSUEXE Addres of the managed object
IDRSUEXE identifierRSUEXE
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get RSUEXE STAT:NAME=RSUSWLH:9/RSUEXE:0;
Get RSUEXE STAT:IDRSUEXE="userLabel"-MPCC-"M10800.ABS";
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.


A30808-X3247-M230-6-7619

1091
CML:BSC RSUPCH
Id:0900d805800d42d3
RSUPCH
The RSUPCH (Replaceable Software Unit Patch) represents an instance of a managed
object class identifying a software patch related to e.g. MPCC, TDPC or PPXU proces-
sors.
The RSUPCH object also handles the unpatch (if any) associated to a software patch.
The unpatch is a particular patch that allows to remove a patch without any system
downtime. Each unpatch is associated to a specific patch.
400 instances for this object are allowed.
All related commands (except CREATE RSUPCH) consist of two fields but only one can
be used (NAME or USER LABEL SWLH).
CREATE RSUPCH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH CREATE RSUPCH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to perform the download of a single patch file (and of the related
unpatch file, if any) on the BSC disk.
Long Names:
IDRSUPCH Addres of the managed object
ULAB userLabel
PROCTYPE processorType
PERM permanent
PRIOSLOTN prioritySlotNumber
SRCPATH relatedFiles
ULABSWLH userLabelSwLoadHeader
System Responses:
- Operation Completed
None.
- Operation Failed
CREATE RSUPCH ULAB= ,PROCTYPE= ,PERM= [,PRIOSLOTN=] ,SRC-
PATH= ,ULABSWLH=;


1092 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d3
RSUPCH
NACK CAUSES:
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
No download in progress with this transfer identifier.
Delete command not allowed for a permanent RSUPCH.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INVALID_PARAMETER_NCK
The file name is too long (a maximum of 14 characters is admitted).
The object address is incorrect.
Wrong processor type specified.
Wrong initial letter for the patch file name.
File name already used for another RSUPCH.
Only the file name extensions .PCH and .BAK are allowed for a
RSUPCH object.
The creation of a RSUPCH unpatch object without the related
RSUPCH patch object is rejected.
File name already used for another RSUPCH.
Processor type attribute of the RSUPCH is different from RSUEXE
one.
The RSUPCH has same UserLabel attribute of related RSUSWLH.
A creation of two RSUPCHs with the same UserLabel and belonging
to the same RSUEXE is occurred.
The file related to the new object is already used for another RSU
object.
The object already exists but with different attributes.
The creation of RSUPCH unpatch object with slot attribute different
from NULL VALUE is rejected.
The creation of a RSUPCH object with a slot number equal to another
one already present is rejected.
A RSUPCH object with permanent attribute TRUE and slot number
NULL is not admitted.
The slot number is equal to another already present.
Slot value out of range.


A30808-X3247-M230-6-7619

1093
CML:BSC RSUPCH
Id:0900d805800d42d3
Application Guidelines:
1. The RSUPCH object instance can be created only if the related RSUEXE object
instance has been already created and if the related patch file is present on the LMT
hard disk.
2. The specific patch file name extension must be PCH.
3. The specific unpatch file name extension must be BAK.
4. In case the file name extension is BAK the PERM attribute must be set at FALSE.
5. The RSUPCH object cannot have the same userLabel of the SW load that contains
it.
6. The RSUPCH unpatch object can be created only if the related RSUPCH patch
object instance has been already created.
Example of Command Execution:
Create RSUPCH:ULAB="M1140000",PROCTYP=MPCC,PERM=TRUE,
Max slot number has been assigned to another patch: you must
specify a slot for the new patch or modify the max slot for the patch
present.
NO_INSTANCE_FREE
The maximum number of RSUPCH instances is already created.
SW_LOAD_HEADER_NOT_FOUND_NCK
The RSUEXE owning this RSUPCH is not existent.
PROCESSING_ERROR_NCK
The creation of the new object instance is failed.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
DUPLICATED_OBJECT
The involved object instance is already present.
DUPLICATED_OBJECT_RSU_DISABLED
The involved object instance already exists but a recovery download
can be performed.
CREATE_UNPATCH_NOT_ALLOWED_WITHOUT_RELATED_PATCH
In case the file name extension is BAK the related patch object must
be already present (created). The specific unpatch file has to be
available on LMT disk and it must have the same file name of the
related patch with the extension PCH.
PATCH_SW_VERSION_NOT_COMPATIBLE
The patch (unpatch) SW version, contained into the related file, must
be compatible with the one of the RSUEXE containing it. If this is not
verified the created patch (unpatch) is put in DISABLED-FAILED
state.


1094 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d3
RSUPCH
PRIOSLOTN=10, SRCPATH="D:\BR61\BSC\hb010043\M1140000.PCH",ULAB-
SWLH="HB010043.SWL";
DELETE RSUPCH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH DELETE RSUPCH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the RSUPCH object and also its related (if any) unpatch.
Long Names:
NAME Addres of the managed object
IDRSUPCH identifierRSUPCH
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
DELETE RSUPCH NAME=RSUSWLH:0..59/RSUEXE:0..249/RSUPCH:0..399
[,IDRSUPCH=];
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
The deletion of a RSUPCH with the permanent attribute TRUE or
belonging to a ESUSW pointed by an OSUSW attribute is allowed
only if the RSUPCH is DISABLED-FAILED.
Delete command not allowed for a RSUPCH whose status is not OFF
DUTY.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK


A30808-X3247-M230-6-7619

1095
CML:BSC RSUPCH
Id:0900d805800d42d3
Application Guidelines:
1. If RSUPCH instance has AVS attribute different from OFF_DUTY or it has PERM
attribute equal to TRUE and is related to a BSCESUSW or a NEYESUSW instance
pointed by backupESU, runningESU, newESU or fallbackESU attribute of
BSCOSUSW or a NEYESUSW, the command is not allowed.
2. The patch deletion implies an automatic deletion of the related (if any) unpatch.
3. In case the command is applied to unpatch object, the specific unpatch object has
to be present.
4. If the RSUPCH object to delete has got .PCH extension, the related RSUPCH
unpatch .BAK is deleted too (if any).
Example of Command Execution:
Delete RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0;
Delete RSUPCH:IDRSUPCH="userLabel SWLH"-"userLabel"-MPCC;
GET RSUPCH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH GET RSUPCH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve values of the different attributes of the RSUPCH
object.
Long Names:
IDRSUPCH Addres of the managed object
IDRSUPCH identifierRSUPCH
ULAB userLabel
PROCTYPE processorType
PERM permanent
PRIOSLOTN prioritySlotNumber
RELF relatedFiles
An internal susystem abort has occurred.
GET RSUPCH IDRSUPCH= [,REQATTL= ULAB ,PROCTYPE ,PERM ,PRI-
OSLOTN ,RELF];


1096 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d3
RSUPCH
System Responses:
- Operation Completed
GET RSUPCH BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
ULAB: userLabel
PROCTYP: processorType
PERM: permanent
PRIOSLOTN: prioritySlotNumber
RELF: relatedFiles
ULAB: userLabel
PROCTYP: processorType
PERM: permanent
RELF: relatedFiles
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal subsystem abort has occurred.
INVALID_PARAMETER_NCK
If the command is a GET RSUPCH object instance.
SW_LOAD_HEADER_NOT_FOUND_NCK
If the command is a GET RSUPCH object instance.
NO_INSTANCE_FREE
If the command is a GET RSUPCH object instance.


A30808-X3247-M230-6-7619

1097
CML:BSC RSUPCH
Id:0900d805800d42d3
GET RSUPCH BASICS
None.
Example of Command Execution:
Get RSUPCH:
NAME=RSUSWLH:1/RSUEXE:0/RSUPCH:0,
REQATTL=ULAB&PROCTYP&PERM&PRIOSLOTN&RELF;
Get RSUPCH:IDRSUPCH="userLabel SWLH"-"userLabel"-MPCC;
GET RSUPCH BASICS
Get RSUPCH BASICS:NAME=RSUSWLH:9/RSUEXE:1/RSUPCH:9;
Get RSUPCH BASICS:
IDRSUPCH="userLabelSWLH"-"userLabelPCH"-TDPC;
GET RSUPCH BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH GET RSUPCH BASICS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve values of the different attributes of the RSUPCH
object.
Long Names:
IDRSUPCH Addres of the managed object
ULAB userLabel
PROCTYPE processorType
PERM permanent
PRIOSLOTN prioritySlotNumber
RELF relatedFiles
System Responses:
See GET RSUPCH
Application Guidelines:
See GET RSUPCH
GET RSUPCH BASICS ;


1098 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d3
RSUPCH
Example of Command Execution:
See GET RSUPCH
GET RSUPCH STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH GET RSUPCH STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
RSUPCH object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
IDRSUPCH Addres of the managed object
IDRSUPCH identifierRSUPCH
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET RSUPCH STAT IDRSUPCH=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.


A30808-X3247-M230-6-7619

1099
CML:BSC RSUPCH
Id:0900d805800d42d3
Example of Command Execution:
Get RSUPCH STAT:NAME=RSUSWLH:9/RSUEXE:1/RSUPCH:9;
Get RSUPCH STAT:IDRSUPCH="userLabelSWLH"-"userLabelPCH"-TDPC;
LOADPATCH RSUPCH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH LOADPATCH RSUPCH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to the operator to load the patch. A command acknowledge is
request by the system by means of a window CLI message ("LOADPATCH RSUPCH:
EXECUTE COMMAND?"); if OK is selected, the command will be executed.
Long Names:
IDRSUPCH Addres of the managed object
IDRSUPCH identifierRSUPCH
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
LOADPATCH RSUPCH IDRSUPCH=;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
The RSUPCH does not belong to the running BSCESUSW.
The phase of the BSCOSUSW is different from IDLE.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INCONSISTENT_STATE_NCK
DISABLED RSUPCH can not be loaded.


1100 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d3
RSUPCH
Application Guidelines:
1. To perform this command OperationalState attribute of RSUPCH object must be
ENABLED and the Load Usage state attribute of BSCOSUSW object must be IDLE.
2. The command is allowed only for a RSUPCH patch object with .PCH extension.
Example of Command Execution:
Loadpatch RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0;
Loadpatch RSUPCH:IDRSUPCH="uselLabelSWLH"-"userLabelPCH"-MPCC;
SET RSUPCH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH SET RSUPCH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs enabling or disabling of the RSUPCH object, that is, referenced
patch can be set to permanent or not (PERM parameter). This command performs also
a slot number useful to give an order during a bring up operation to the patches to be
loaded.
Long Names:
NAME Addres of the managed object
IDRSUPCH identifierRSUPCH
PERM permanent
PRIOSLOTN prioritySlotNumber
System Responses:
- Operation Completed
None.
- Operation Failed
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
LOAD_PATCH_NOT_ALLOWED_FOR_AN_UNPATCH_OBJ
The command is applicable only to a RSUPCH object with file name
extension PCH.
SET RSUPCH NAME=RSUSWLH:0..59/RSUEXE:0..249/RSUPCH:0..399
[,IDRSUPCH=] [,PERM=] [,PRIOSLOTN=];


A30808-X3247-M230-6-7619

1101
CML:BSC RSUPCH
Id:0900d805800d42d3
NACK CAUSES:
Application Guidelines:
1. To perform an enabling patch (permanent), OperationalState attribute of the
RSUPCH object must be ENABLED and the Load Usage state attribute of
BSCOSUSW object must be IDLE.
2. To perform a disabling patch (not permanent), the specific RSUPCH object has to
be available on BSC disk and the Load Usage state attribute of BSCOSUSW must
be IDLE.
3. The command is allowed only for a RSUPCH patch object with .PCH extension.
4. It is not allowed to set a RSUPCH patch permanent TRUE and slot NULL.
Example of Command Execution:
Set RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0,PERM=TRUE,
PRIOSLOTN=10;
Set RSUPCH:
IDRSUPCH="userLabelSWLH"-"userLabelPCH"-SWLH,PERM=TRUE,
PRIOSLOTN=10;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
BSCOSUSW phase different from IDLE.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
INCONSISTENT_STATE_NCK
The PERM attribute of a DISABLE RSUPCH can not be set at TRUE
value.
INVALID_PARAMETER_NCK
A RSUPCH object with permanent attribute TRUE and slot number
NULL is not admitted.
The slot number is equal to another one already present.
Slot value out of range.
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
SET_NOT_ALLOWED_FOR_AN_UNPATCH
The RSUPCH object contained in the command has to be linked to a
file with extension PCH.


1102 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d3
RSUPCH
UNLOADPCH RSUPCH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH RSUEXE
RSUPCH UNLOADPCH RSUPCH
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to the operator to unload the patch. A command acknowledge is
request by the system by means of a window CLI message ("UNLOADPATCH
RSUPCH: EXECUTE COMMAND?"); if it is selected OK, the command will be exe-
cuted.
Long Names:
NAME Addres of the managed object
IDRSUPCH identifierRSUPCH
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
UNLOADPCH RSUPCH NAME=RSUSWLH:0..59/RSUEXE:0..249/RSUPCH:0..399
[,IDRSUPCH=];
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
The RSUPCH does not belong to the running BSCESUSW.
The BSCOSUSW phase is different from IDLE.
NO_TASK_AVAILABLE
No free servers to perform the command.
OBJECT_NOT_FOUND
The object involved in this command does not exist.
No unload patch command is allowed. The related RSUPCH object
with file name extension BAK doesn't exist.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INCONSISTENT_STATE_NCK
A DISABLED RSUPCH can not be loaded.


A30808-X3247-M230-6-7619

1103
CML:BSC RSUPCH
Id:0900d805800d42d3
Application Guidelines:
1. The PERM attribute must be set at FALSE.
2. To perform this command the RSUPCH availability status must be NONE and the
OperationalState attribute of the related unpatch must be ENABLED.
3. When the unload patch succeeds the patch availability status changes from NONE
to OFF DUTY.
4. The command is allowed only for a RSUPCH patch object with .PCH extension.
Example of Command Execution:
Unloadpch RSUPCH:NAME=RSUSWLH:0/RSUEXE:0/RSUPCH:0;
Unloadpch RSUPCH:IDRSUPCH="uselLabelSWLH"-"userLabelPCH"-MPCC;
Unload patch command not allowed for a RSUPCH whose avail.
status is not NONE.
INVALID_PARAMETER_NCK
Unload patch command not allowed for a permanent RSUPCH.
ABORT_BY_SYSTEM_NCK
This command is rejected due to an internal subsystem abort.
UNLOAD_PATCH_NOT_ALLOWED_FOR_AN_UNPATCH_OBJ
The command is applicable only to a RSUPCH object with file name
extension PCH.


1104 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d6
RSUSWLH
RSUSWLH
The RSUSWLH (Replaceable Software Unit SW Load Headers) object class identifies
the software load header files.
60 instances for this object are allowed.
All related commands (except CREATE RSUSWLH) consist of two fields but only one
can be used (NAME or USER LABEL SWLH).
CREATE RSUSWLH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH CREATE
RSUSWLH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to execute the download of a software load header file on a BSC
disk.
Long Names:
IDRSUSWLH Addres of the managed object
ULAB userLabel
SRCPATH relatedFiles
DNLALLEXE DnlAllExe
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
CREATE RSUSWLH ULAB= ,SRCPATH= ,DNLALLEXE=;
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
No download in progress with this transfer identifier.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
ABORT_BY_SYSTEM_NCK


A30808-X3247-M230-6-7619

1105
CML:BSC RSUSWLH
Id:0900d805800d42d6
Application Guidelines:
1. A RSUSWLH can not be created if the related file has the same version of another
file related to a RSUSWLH object already created.
2. A RSUSWLH can not be created if it has the same user label and Network Element
of another one created.
3. The creation of a RSUSWLH instance implies the automatic creation of the related
BSCESUSW or NEYESUSW instance (depending on the fact that the software load
belongs to the BSC or to BTSM/TRAU equipment).
Example of Command Execution:
Create RSUSWLH:ULAB="Milano_Test",SRC-
PATH="D:\BR61\BSC\hb010140\Hb010140.swl",DNLALLEXE=YES;
An internal system abort is occurred.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INVALID_PARAMETER_NCK
The file name is too long (a maximum of 14 characters is admitted).
The object address is incorrect.
The userLabel attribute already used for another RSUSWLH of the
same NE type.
The software version already used for another RSUSWLH of the
same NE type.
The NE attribute specified in the command does not exist.
The file related to the new object is already used for another RSU
object.
The object is already existing but with different attributes.
NO_INSTANCE_FREE
The maximum number of ESUSW (NE or BSC) instances is already
created.
PROCESSING_ERROR_NCK
The creation of the new object instance is failed.
The object address is not available.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
DUPLICATED_OBJECT
The involved object instance is already present.
DUPLICATED_OBJECT_RSU_DISABLED
The involved object instance already exists but a recovery download
can be performed.


1106 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d6
RSUSWLH
DELETE RSUSWLH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH DELETE
RSUSWLH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command performs a deletion of a RSUSWLH object.
Long Names:
NAME Addres of the managed object
IDRSUSWLH identifierRSUSWLH
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
DELETE RSUSWLH NAME=RSUSWLH:0..59 [,IDRSUSWLH=];
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
ESU_OBJ_POINTED_BY_OSU_ATTR
The related BSCESUSW object can not be deleted (it is pointed by
one of the OSUSW attributes).
The related NEYESUSW object can not be deleted (it is pointed by
the backup attribute of one of the OSUSW attributes).


A30808-X3247-M230-6-7619

1107
CML:BSC RSUSWLH
Id:0900d805800d42d6
Application Guidelines:
1. A RSUSWLH cannot be created if it has the same software version and Network
Element of another one created.
2. The deletion of RSUSWLH object implies the deletion of all the RSUEXE objects
contained into it; and consequently implies the deletion of all RSUPCH objects con-
tained into the deleted RSUEXE.
3. After the deletion of RSUSWLH object, the related BSCESUSW or NEYESUSW
objects are also deleted.
Example of Command Execution:
Delete RSUSWLH:NAME=RSUSWLH:0;
Delete RSUSWLH:IDRSUSWLH="userLabelSWLH"-BSC;
GET RSUSWLH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH GET
RSUSWLH
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the different attributes of RSUSWLH
object.
Long Names:
IDRSUSWLH Addres of the managed object
IDRSUSWLH identifierRSUSWLH
ULAB userLabel
VER version
NTWEL networkElement
RELF relatedFiles
System Responses:
- Operation Completed
GET RSUSWLH IDRSUSWLH= [,REQATTL= ULAB ,VER ,NTWEL ,RELF];
ULAB: userLabel
VER version
NTWEL networkElement
RELF: relatedFiles


1108 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d6
RSUSWLH
GET RSUSWLH BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
If a GET RSUSWLH command is issued with a wrong USER LABEL SWLH in the IDR-
SUSWLH attribute, the field 'Object Instance' of the LMT Message Browser might
include a free RSUSWLH instance, rather than being 'n.a.'.
GET RSUSWLH BASICS
None.
Example of Command Execution:
Get RSUSWLH:NAME=RSUSWLH:0,REQATTL=VER&NTWEL&RELF;
Get RSUSWLH:IDRSUSWLH="userLABELSWLH"-
BSC,REQATTL=VER&NTWEL&RELF;
GET RSUSWLH BASICS
Get RSUSWLH BASICS:NAME=RSUSWLH:0;
Get RSUSWLH BASICS:IDRSUSWLH="userLabelSWLH"-BSC;
VER version
NTWEL networkElement
RELF: relatedFiles
NO_INSTANCE_FREE
If the command is a GET RSUSWLH object instance.
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.


A30808-X3247-M230-6-7619

1109
CML:BSC RSUSWLH
Id:0900d805800d42d6
GET RSUSWLH BASICS
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH GET
RSUSWLH BASICS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of the different attributes of RSUSWLH
object.
Long Names:
IDRSUSWLH Addres of the managed object
ULAB userLabel
VER version
NTWEL networkElement
RELF relatedFiles
System Responses:
See GET RSUSWLH
Application Guidelines:
See GET RSUSWLH
Example of Command Execution:
See GET RSUSWLH
GET RSUSWLH STAT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH GET
RSUSWLH STAT
Applicability:
Phase 2.
Visibility level: 0.
GET RSUSWLH
BASICS
;
GET RSUSWLH STAT IDRSUSWLH=;


1110 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d6
RSUSWLH
Command Description:
This command is used to retrieve the following State/Status attributes related to the
RSUSWLH object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
IDRSUSWLH Addres of the managed object
IDRSUSWLH identifierRSUSWLH
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get RSUSWLH STAT:NAME=RSUSWLH:0;
Get RSUSWLH STAT:IDRSUSWLH="userLabelSWLH"-BSC;
SET RSUSWLH
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT RSUSWLH SET
RSUSWLH
Applicability:
Phase 2.
Visibility level: 2.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SM_TOO_BUSY
The message occurs when the Status Handler task is performing the
maximum number of commands.
SET RSUSWLH NAME=RSUSWLH:0..59 [,IDRSUSWLH=] ,ULAB=;


A30808-X3247-M230-6-7619

1111
CML:BSC RSUSWLH
Id:0900d805800d42d6
Command Description:
This command performs a change of the userLabel attribute of RSUSWLH object.
Long Names:
NAME Addres of the managed object
IDRSUSWLH identifierRSUSWLH
ULAB userLabel
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
If the specific userLabel value is already present the command is rejected.
Example of Command Execution:
Set RSUSWLH:NAME=RSUSWLH:0,ULAB="userlabelNEW";
Set RSUSWLH:IDRSUSWLH="userLabelSWLH"-BSC,ULAB="userLabelNEW";
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers are available to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INVALID_PARAMETER_NCK
The userLabel attribute already used for another RSUSWLH of the
same NE type.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.


1112 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
SCA
SCA (Smart Carrier Allocation) provides histograms of frequency based measurements
and elaborates them to determine a list of ranked frequencies. This list then indicates
the best substitute for a frequency that is being tested e.g. for a microcell or to be used
in case of interference. The resulting reduction of interference achieved here offers
benefits especially for micro cellular and pico cellular layers.
The SCA object allows performing up to three new types of measures (Normal Measure,
Busy Cumulative Measure and Extended Idle Channel Measure). The operator can
choose those kind of measure types he wants to trace and also the list of frequencies to
put under observation; for the Busy Cumulative Measures, the frequencies list is not
required.
CREATE SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA CREATE SCA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the user to create a SCAN object; this object can be created for
each existing BTS.
The operator must select the GSM frequency band and he also can select:
the measure type, enabling the related flag;
the observation period;
the accumulation times (up to 4 accumulation times per day in the range 6 a.m. to
23 p.m.);
the list of frequencies to be put under observation.
The operator can set up to 64 frequencies for each GSM band (P, E, GSM1800,
GSMR, GSM1900) and no more than one band at a time.
The allowed BAND values for a given SYSID (frequency band used by the cell) are
highlighted in the following table; the SYSID parameter is defined when the user creates
the BTS object.
CREATE SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0 ,BAND=
[,START=] [,STOP=] [,ATIME<n>=] [,ENMDL=] [,EBUSY-
CUM=] [,EEICM=] [,NMDLATT<nn>=] [,EICNF<nn>=];
BAND
P E DCS1800 PCS1900 GSMR GSM850
BB900 X --- --- --- --- ---


A30808-X3247-M230-6-7619

1113
CML:BSC SCA
Id:0900d805800d42d9
Long Names:
NAME Addres of the managed object
BAND band
START startDate
STOP stopDate
ATIME<n> accumulationTime<n>
ENMDL enableNormalMeas
EBUSYCUM enableBusyCumulMeas
EEICM enableExtIdleChanMeas
NMDLATT<nn> normalMeasAttr<nn>
EICNF<nn> extIdleChanFreq<nn>
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
EXT900 X X --- --- --- ---
SYSID GSMR --- --- --- --- X ---
GSMDCS X X X --- --- ---
DCS1800 --- --- X --- --- ---
PCS1900 --- --- --- X --- ---
GSM850 --- --- --- --- --- X
GSM850PCS --- --- --- X --- X
GSM850DCS X X
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The superordinate objects BTSM and BTS must be already
equipped.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE
All the frequencies under observation must belong to the specified
band.
UNSUCCESSFUL_INVALID_ATTRIBUTES
BAND
P E DCS1800 PCS1900 GSMR GSM850


1114 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
Application Guidelines:
1. The object is created in LOCKED state; if the object is get by BTSM it will be not
equipped. To put it in service and to create it on Abis interface an unlock command
is required.
2. At least one type of measure must be traced.
3. The STOP attribute must be set at a value greater or equal to the value of START.
4. The STOPTIME field of ATIME<nn> parameter must be set at a value greater or
equal to the value of STARTTIME field.
5. If the flag ENMDL (or EEICM) is enabled the relative NMDLATT<nn> (or
EICNF<nn>) measures must be set; moreover, the EICNF<nn> parameters must
refer to different frequencies.
6. BTSs equipped with TPU1 cannot support the EICM Feature.
Example of Command Execution:
Normal Measure
Create SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=DCS,START=1-Jan-2001,
STOP=31-Dec-2001,ATIME1=(6-0)-(8-59),ATIME2=(10-0)-(11-59),
ATIME3=(13-0)-(15-59),ATIME4=(21-0)-(23-59),ENMDL=TRUE,
NMDLATT1=701-0-0,NMDLATT2=701-0-0,NMDLATT3=702-0-0,
NMDLATT4=703-0-0,NMDLATT5=704-0-0,NMDLATT6=705-0-0,
NMDLATT7=706-0-0,NMDLATT8=707-0-0,NMDLATT9=708-0-0,
NMDLATT10=709-0-0,NMDLATT11=710-0-0,NMDLATT12=711-0-0;
One or more attributes have been incorrectly set. For more details
see Application Guidelines n. 3, 4, 5.
UNSUCCESSFUL_OVERLAPPED_PERIODS
The accumulation time periods must not have intersections.
UNSUCCESSFUL_FREQUENCY_ALREADY_TRACED
The EICNF<nn> attributes must refer to different frequencies.
UNSUCCESSFUL_BCCH_BSIC_ALREADY_TRACED
The set bcchFrequency-netColorCode-bsColorCode has already
been traced in an other NMDLATT<nn> parameter.
FREQUENCY_NOT_ALLOWED
The frequencies traced in EICNF<nn> attributes must differ from
each other at least of more than 200 kHz.
UNSUCCESSFUL_BAND_INCONSISTENT
The selected band is not consistent with the SYSID used by the cell.
UNSUCCESSFUL_INVALID_BCCH_FREQUENCY
The BCCH frequency specified in the NMDLATT<nn> attribute must
belong to an existent ADJC of the cell related to the SCA.


A30808-X3247-M230-6-7619

1115
CML:BSC SCA
Id:0900d805800d42d9
Extended Idle Channel Measure
Create SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=PCS,START=1-Jan-2001,
STOP=31-Dec-2001,ATIME1=(6-0)-(10-59),ATIME2=(12-0)-(16-
59),EEICM=TRUE,
EICNF1=512,EICNF2=514,EICNF3=516,EICNF4=518,EICNF5=520,EICNF6=522,
EICNF7=524,EICNF8=526,EICNF9=528,EICNF10=530,EICNF11=532,EICNF12=
534,EICNF13=536;
Busy Cumulative Measure
Create SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=P,START=1-Jan-2001,
STOP=31-Dec-2001,ATIME1=(6-0)-(7-59),ATIME2=(12-0)-(13-59),
ATIME3=(16-0)-(17-59),ATIME4=(21-0)-(22-59),ENMDL=FALSE,
EBUSYCUM=TRUE,EEICM=FALSE;
DELETE SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA DELETE SCA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a SCA instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
DELETE SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCA, the relative object instance must be in LOCKED
state.


1116 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
Application Guidelines:
When the state of the SCA object is set at LOCK the relative measurement results will
be deleted on BTS, so the operator has to give first an UPLOADREQ SCA command if
he does not want to lose any information.
Example of Command Execution:
Delete SCA:NAME=BTSM:0/BTS:0/SCA:0;
GET SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the values of the parameters selected by the operators
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
BAND band
START startDate
STOP stopDate
ATIME<n> accumulationTime<n>
ENMDL enableNormalMeas
EBUSYCUM enableBusyCumulMeas
EEICM enableExtIdleChanMeas
NMDLATT<nn> normalMeasAttr<nn>
EICNF<nn> extIdleChanFreq<nn>
System Responses:
- Operation Completed
GET SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0 [,REQATTL=
BAND ,START ,STOP ,ATIME<n> ,ENMDL ,EBUSYCUM
,EEICM ,NMDLATT<nn> ,EICNF<nn>];
GET ACK SCAN:
NAME: name
BAND: band
START: startDate


A30808-X3247-M230-6-7619

1117
CML:BSC SCA
Id:0900d805800d42d9
STOP: stopDate
ATIME1: accumulationTime1
ATIME2: accumulationTime2
ATIME3: accumulationTime3
ATIME4: accumulationTime4
ENMDL: enableNormalMeas
EBUSYCUM: enableBusyCumulMeas
EEICM: enableExtIdleMeas
NMDLATT1: normalMeasAttr1
NMDLATT2: normalMeasAttr2
NMDLATT3: normalMeasAttr3
NMDLATT4: normalMeasAttr4
NMDLATT5: normalMeasAttr5
NMDLATT6: normalMeasAttr6
NMDLATT7: normalMeasAttr7
NMDLATT8: normalMeasAttr8
NMDLATT9: normalMeasAttr9
NMDLATT10
:
normalMeasAttr10
NMDLATT11
:
normalMeasAttr11
NMDLATT12
:
normalMeasAttr12
NMDLATT13
:
normalMeasAttr13
NMDLATT14
:
normalMeasAttr14
NMDLATT15
:
normalMeasAttr15
NMDLATT16
:
normalMeasAttr16
NMDLATT17
:
normalMeasAttr17
NMDLATT18
:
normalMeasAttr18
NMDLATT19
:
normalMeasAttr19
NMDLATT20
:
normalMeasAttr20


1118 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
NMDLATT21
:
normalMeasAttr21
NMDLATT22
:
normalMeasAttr22
NMDLATT23
:
normalMeasAttr23
NMDLATT24
:
normalMeasAttr24
NMDLATT25
:
normalMeasAttr25
NMDLATT26
:
normalMeasAttr26
NMDLATT27
:
normalMeasAttr27
NMDLATT28
:
normalMeasAttr28
NMDLATT29
:
normalMeasAttr29
NMDLATT30
:
normalMeasAttr30
NMDLATT31
:
normalMeasAttr31
NMDLATT32
:
normalMeasAttr32
NMDLATT33
:
normalMeasAttr33
NMDLATT34
:
normalMeasAttr34
NMDLATT35
:
normalMeasAttr35
NMDLATT36
:
normalMeasAttr36
NMDLATT37
:
normalMeasAttr37
NMDLATT38 normalMeasAttr38
NMDLATT39
:
normalMeasAttr39
NMDLATT40
:
normalMeasAttr40
NMDLATT41
:
normalMeasAttr41


A30808-X3247-M230-6-7619

1119
CML:BSC SCA
Id:0900d805800d42d9
NMDLATT42
:
normalMeasAttr42
NMDLATT43
:
normalMeasAttr43
NMDLATT44
:
normalMeasAttr44
NMDLATT45
:
normalMeasAttr45
NMDLATT46
:
normalMeasAttr46
NMDLATT47
:
normalMeasAttr47
NMDLATT48
:
normalMeasAttr48
NMDLATT49
:
normalMeasAttr49
NMDLATT50
:
normalMeasAttr50
NMDLATT51
:
normalMeasAttr51
NMDLATT52
:
normalMeasAttr52
NMDLATT53
:
normalMeasAttr53
NMDLATT54
:
normalMeasAttr54
NMDLATT55
:
normalMeasAttr55
NMDLATT56
:
normalMeasAttr56
NMDLATT57
:
normalMeasAttr57
NMDLATT58
:
normalMeasAttr58
NMDLATT59
:
normalMeasAttr59
NMDLATT60
:
normalMeasAttr60
NMDLATT61
:
normalMeasAttr61
NMDLATT62
:
normalMeasAttr62


1120 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
NMDLATT63
:
normalMeasAttr63
EICNF1: extIdleChanFreq1
EICNF2: extIdleChanFreq2
EICNF3: extIdleChanFreq3
EICNF4: extIdleChanFreq4
EICNF5: extIdleChanFreq5
EICNF6: extIdleChanFreq6
EICNF7: extIdleChanFreq7
EICNF8: extIdleChanFreq8
EICNF9: extIdleChanFreq9
EICNF10: extIdleChanFreq10
EICNF11: extIdleChanFreq11
EICNF12: extIdleChanFreq12
EICNF13: extIdleChanFreq13
EICNF14: extIdleChanFreq14
EICNF15: extIdleChanFreq15
EICNF16: extIdleChanFreq16
EICNF17: extIdleChanFreq17
EICNF18: extIdleChanFreq18
EICNF19: extIdleChanFreq19
EICNF20: extIdleChanFreq20
EICNF21: extIdleChanFreq21
EICNF22: extIdleChanFreq22
EICNF23: extIdleChanFreq23
EICNF24: extIdleChanFreq24
EICNF25: extIdleChanFreq25
EICNF26: extIdleChanFreq26
EICNF27: extIdleChanFreq27
EICNF28: extIdleChanFreq28
EICNF29: extIdleChanFreq29
EICNF30: extIdleChanFreq30
EICNF31: extIdleChanFreq31
EICNF32: extIdleChanFreq32
EICNF33: extIdleChanFreq33
EICNF34: extIdleChanFreq34
EICNF35: extIdleChanFreq35


A30808-X3247-M230-6-7619

1121
CML:BSC SCA
Id:0900d805800d42d9
GET SCA BASICS
EICNF36: extIdleChanFreq36
EICNF37: extIdleChanFreq37
EICNF38: extIdleChanFreq38
EICNF39: extIdleChanFreq39
EICNF40: extIdleChanFreq40
EICNF41: extIdleChanFreq41
EICNF42: extIdleChanFreq42
EICNF43: extIdleChanFreq43
EICNF44: extIdleChanFreq44
EICNF45: extIdleChanFreq45
EICNF46: extIdleChanFreq46
EICNF47: extIdleChanFreq47
EICNF48: extIdleChanFreq48
EICNF49: extIdleChanFreq49
EICNF50: extIdleChanFreq50
EICNF51: extIdleChanFreq51
EICNF52: extIdleChanFreq52
EICNF53: extIdleChanFreq53
EICNF54: extIdleChanFreq54
EICNF55: extIdleChanFreq55
EICNF56: extIdleChanFreq56
EICNF57: extIdleChanFreq57
EICNF58: extIdleChanFreq58
EICNF59: extIdleChanFreq59
EICNF60: extIdleChanFreq60
EICNF61: extIdleChanFreq61
EICNF62: extIdleChanFreq62
EICNF63: extIdleChanFreq63
EICNF64: extIdleChanFreq64
GET ACK SCAN:
NAME: name
BAND: band
START: startDate


1122 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
GET SCA EICM
STOP: stopDate
ATIME1: accumulationTime1
ATIME2: accumulationTime2
ATIME3: accumulationTime3
ATIME4: accumulationTime4
ENMDL: enableNormalMeas
EBUSYCUM: enableBusyCumulMeas
EEICM: enableExtIdleMeas
GET ACK SCAN:
NAME: name
EICNF1: extIdleChanFreq1
EICNF2: extIdleChanFreq2
EICNF3: extIdleChanFreq3
EICNF4: extIdleChanFreq4
EICNF5: extIdleChanFreq5
EICNF6: extIdleChanFreq6
EICNF7: extIdleChanFreq7
EICNF8: extIdleChanFreq8
EICNF9: extIdleChanFreq9
EICNF10: extIdleChanFreq10
EICNF11: extIdleChanFreq11
EICNF12: extIdleChanFreq12
EICNF13: extIdleChanFreq13
EICNF14: extIdleChanFreq14
EICNF15: extIdleChanFreq15
EICNF16: extIdleChanFreq16
EICNF17: extIdleChanFreq17
EICNF18: extIdleChanFreq18
EICNF19: extIdleChanFreq19
EICNF20: extIdleChanFreq20
EICNF21: extIdleChanFreq21
EICNF22: extIdleChanFreq22
EICNF23: extIdleChanFreq23
EICNF24: extIdleChanFreq24


A30808-X3247-M230-6-7619

1123
CML:BSC SCA
Id:0900d805800d42d9
EICNF25: extIdleChanFreq25
EICNF26: extIdleChanFreq26
EICNF27: extIdleChanFreq27
EICNF28: extIdleChanFreq28
EICNF29: extIdleChanFreq29
EICNF30: extIdleChanFreq30
EICNF31: extIdleChanFreq31
EICNF32: extIdleChanFreq32
EICNF33: extIdleChanFreq33
EICNF34: extIdleChanFreq34
EICNF35: extIdleChanFreq35
EICNF36: extIdleChanFreq36
EICNF37: extIdleChanFreq37
EICNF38: extIdleChanFreq38
EICNF39: extIdleChanFreq39
EICNF40: extIdleChanFreq40
EICNF41: extIdleChanFreq41
EICNF42: extIdleChanFreq42
EICNF43: extIdleChanFreq43
EICNF44: extIdleChanFreq44
EICNF45: extIdleChanFreq45
EICNF46: extIdleChanFreq46
EICNF47: extIdleChanFreq47
EICNF48: extIdleChanFreq48
EICNF49: extIdleChanFreq49
EICNF50: extIdleChanFreq50
EICNF51: extIdleChanFreq51
EICNF52: extIdleChanFreq52
EICNF53: extIdleChanFreq53
EICNF54: extIdleChanFreq54
EICNF55: extIdleChanFreq55
EICNF56: extIdleChanFreq56
EICNF57: extIdleChanFreq57
EICNF58: extIdleChanFreq58
EICNF59: extIdleChanFreq59
EICNF60: extIdleChanFreq60


1124 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
GET SCA NMDL
EICNF61: extIdleChanFreq61
EICNF62: extIdleChanFreq62
EICNF63: extIdleChanFreq63
EICNF64: extIdleChanFreq64
GET ACK SCAN:
NAME: name
NMDLATT1: normalMeasAttr1
NMDLATT2: normalMeasAttr2
NMDLATT3: normalMeasAttr3
NMDLATT4: normalMeasAttr4
NMDLATT5: normalMeasAttr5
NMDLATT6: normalMeasAttr6
NMDLATT7: normalMeasAttr7
NMDLATT8: normalMeasAttr8
NMDLATT9: normalMeasAttr9
NMDLATT10
:
normalMeasAttr10
NMDLATT11
:
normalMeasAttr11
NMDLATT12
:
normalMeasAttr12
NMDLATT13
:
normalMeasAttr13
NMDLATT14
:
normalMeasAttr14
NMDLATT15
:
normalMeasAttr15
NMDLATT16
:
normalMeasAttr16
NMDLATT17
:
normalMeasAttr17
NMDLATT18
:
normalMeasAttr18
NMDLATT19
:
normalMeasAttr19


A30808-X3247-M230-6-7619

1125
CML:BSC SCA
Id:0900d805800d42d9
NMDLATT20
:
normalMeasAttr20
NMDLATT21
:
normalMeasAttr21
NMDLATT22
:
normalMeasAttr22
NMDLATT23
:
normalMeasAttr23
NMDLATT24
:
normalMeasAttr24
NMDLATT25
:
normalMeasAttr25
NMDLATT26
:
normalMeasAttr26
NMDLATT27
:
normalMeasAttr27
NMDLATT28
:
normalMeasAttr28
NMDLATT29
:
normalMeasAttr29
NMDLATT30
:
normalMeasAttr30
NMDLATT31
:
normalMeasAttr31
NMDLATT32
:
normalMeasAttr32
NMDLATT33
:
normalMeasAttr33
NMDLATT34
:
normalMeasAttr34
NMDLATT35
:
normalMeasAttr35
NMDLATT36
:
normalMeasAttr36
NMDLATT37
:
normalMeasAttr37
NMDLATT38 normalMeasAttr38
NMDLATT39
:
normalMeasAttr39
NMDLATT40
:
normalMeasAttr40


1126 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
NMDLATT41
:
normalMeasAttr41
NMDLATT42
:
normalMeasAttr42
NMDLATT43
:
normalMeasAttr43
NMDLATT44
:
normalMeasAttr44
NMDLATT45
:
normalMeasAttr45
NMDLATT46
:
normalMeasAttr46
NMDLATT47
:
normalMeasAttr47
NMDLATT48
:
normalMeasAttr48
NMDLATT49
:
normalMeasAttr49
NMDLATT50
:
normalMeasAttr50
NMDLATT51
:
normalMeasAttr51
NMDLATT52
:
normalMeasAttr52
NMDLATT53
:
normalMeasAttr53
NMDLATT54
:
normalMeasAttr54
NMDLATT55
:
normalMeasAttr55
NMDLATT56
:
normalMeasAttr56
NMDLATT57
:
normalMeasAttr57
NMDLATT58
:
normalMeasAttr58
NMDLATT59
:
normalMeasAttr59
NMDLATT60
:
normalMeasAttr60
NMDLATT61
:
normalMeasAttr61


A30808-X3247-M230-6-7619

1127
CML:BSC SCA
Id:0900d805800d42d9
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCA BASICS
None.
GET SCA EICM
None.
GET SCA NMDL
None.
Example of Command Execution:
Get SCA:NAME=BTSM:0/BTS:0/SCA:0,REQATTL=BAND&START&STOP&
ATIME1& ATIME2&ATIME3&ATIME4&ENMDL&EBUSYCUM&EEICM&NMDLATT1&
NMDLATT2&NMDLATT3&NMDLATT4&NMDLATT5&NMDLATT6&NMDLATT7&
NMDLATT8&NMDLATT9&NMDLATT10&NMDLATT11&NMDLATT12&NMDLATT13&
NMDLATT14&NMDLATT15&NMDLATT16&NMDLATT17&NMDLATT18&
NMDLATT19&NMDLATT20&NMDLATT21&NMDLATT22&NMDLATT23&
NMDLATT24&NMDLATT25&NMDLATT26&NMDLATT27&NMDLATT28&
NMDLATT29&NMDLATT30&NMDLATT31&NMDLATT32&NMDLATT33&
NMDLATT34&NMDLATT35&NMDLATT36&NMDLATT37&NMDLATT38&NMDLATT3
9&NMDLATT40&NMDLATT41&NMDLATT42&NMDLATT43&NMDLATT44&NMDLAT
T45&NMDLATT46&NMDLATT47&NMDLATT48&NMDLATT49&NMDLATT50&
NMDLATT51&NMDLATT52&NMDLATT53&NMDLATT54&NMDLATT55&
NMDLATT56&NMDLATT57&NMDLATT58&NMDLATT59&NMDLATT60&
NMDLATT61&NMDLATT62&NMDLATT63&NMDLATT64&EICNF1&EICNF2&
EICNF3&EICNF4&EICNF5&EICNF6&EICNF7&EICNF8&EICNF9&EICNF10&
EICNF11&EICNF12&EICNF13&EICNF14&EICNF15&EICNF16&EICNF17&EICNF18&
EICNF19&EICNF20&EICNF21&EICNF22&EICNF23&EICNF24&EICNF25&EICNF26&
EICNF27&EICNF28&EICNF29&EICNF30&EICNF31&EICNF32&EICNF33&EICNF34&
NMDLATT62
:
normalMeasAttr62
NMDLATT63
:
normalMeasAttr63
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1128 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
EICNF35&EICNF36&EICNF37&EICNF38&EICNF39&EICNF40&EICNF41&EICNF42&
EICNF43&EICNF44&EICNF45&EICNF46&EICNF47&EICNF48&EICNF49&EICNF50&
EICNF51&EICNF52&EICNF53&EICNF54&EICNF55&EICNF56&EICNF57&EICNF58&
EICNF59&EICNF60&EICNF61&EICNF62&EICNF63&EICNF64;
GET SCA BASICS
Get SCA BASICS:NAME=BTSM:0/BTS:0/SCA:0;
GET SCA EICM
Get SCA EICM:NAME=BTSM:0/BTS:0/SCA:0;
GET SCA NMDL
Get SCA NMDL:NAME=BTSM:0/BTS:0/SCA:0;
GET SCA BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the values of the parameters selected by the operators
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
BAND band
START startDate
STOP stopDate
ATIME<n> accumulationTime<n>
ENMDL enableNormalMeas
EBUSYCUM enableBusyCumulMeas
EEICM enableExtIdleChanMeas
System Responses:
See GET SCA
GET SCA BASICS NAME=BTSM:0..199/BTS:0..23/SCA:0..0;


A30808-X3247-M230-6-7619

1129
CML:BSC SCA
Id:0900d805800d42d9
Application Guidelines:
See GET SCA
Example of Command Execution:
See GET SCA
GET SCA EICM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA EICM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the values of the parameters selected by the operators
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
EICNF<nn> extIdleChanFreq<nn>
System Responses:
See GET SCA
Application Guidelines:
See GET SCA
Example of Command Execution:
See GET SCA
GET SCA NMDL
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA NMDL
Applicability:
Phase 2.
Visibility level: 0.
GET SCA EICM NAME=BTSM:0..199/BTS:0..23/SCA:0..0;
GET SCA NMDL NAME=BTSM:0..199/BTS:0..23/SCA:0..0;


1130 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
Command Description:
The command is used to retrieve the values of the parameters selected by the operators
by means of REQATTL field.
Long Names:
NAME Addres of the managed object
NMDLATT<nn> normalMeasAttr<nn>
System Responses:
See GET SCA
Application Guidelines:
See GET SCA
Example of Command Execution:
See GET SCA
GET SCA STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA GET SCA STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the SCA
object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
GET SCA STAT NAME=BTSM:0..199/BTS:0..23/SCA:0..0;


A30808-X3247-M230-6-7619

1131
CML:BSC SCA
Id:0900d805800d42d9
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCA STAT:NAME=BTSM:0/BTS:0/SCA:0;
LOCK SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA LOCK SCA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0;
ALREADY_IN_TARGET_STATE
The object instance is in administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1132 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
Example of Command Execution:
Lock SCA:NAME=BTSM:0/BTS:0/SCA:0
SET SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA SET SCA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to the user to change the setting related to a SCAN object previ-
ously created.
Long Names:
NAME Addres of the managed object
START startDate
STOP stopDate
ATIME<n> accumulationTime<n>
ENMDL enableNormalMeas
EBUSYCUM enableBusyCumulMeas
EEICM enableExtIdleChanMeas
NMDLATT<nn> normalMeasAttr<nn>
EICNF<nn> extIdleChanFreq<nn>
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
SET SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0 [,START=]
[,STOP=] [,ATIME<n>=] [,ENMDL=] [,EBUSYCUM=]
[,EEICM=] [,NMDLATT<nn>=] [,EICNF<nn>=];
UNSUCCESSFUL_INVALID_STATUS
In order to set the selected object it must be in LOCKED state.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE


A30808-X3247-M230-6-7619

1133
CML:BSC SCA
Id:0900d805800d42d9
Application Guidelines:
1. At least one type of measure must be traced.
2. The STOP attribute must be set at a value greater or equal to the value of START.
3. The STOPTIME field of ATIME<nn> parameter must be set at a value greater or
equal to the value of STARTTIME field.
4. If the flag ENMDL (or EBUSYCUM) is enabled the relative NMDLATT<nn> (or
EICNF<nn>) measures must be set; moreover, the EICNF<nn> parameters must
refer to different frequencies.
5. BTSs equipped with TPU1 cannot support the EICM feature.
Example of Command Execution:
Set SCA:NAME=BTSM:0/BTS:0/SCA:0,BAND=DCS,START=1-Jan-2001, STOP=31-
Dec-2001,ATIME1=(6-0)-(8-59),ATIME2=(10-0)-(11-59),
ATIME3=(13-0)-(15-59),ATIME4=(21-0)-(23-59),ENMDL=TRUE,
NMDLATT1=701-0-0,NMDLATT2=701-0-0,NMDLATT3=702-0-0,
NMDLATT4=703-0-0,NMDLATT5=704-0-0,NMDLATT6=705-0-0,
NMDLATT7=706-0-0,NMDLATT8=707-0-0,NMDLATT9=708-0-0,
NMDLATT10=709-0-0,NMDLATT11=710-0-0,NMDLATT12=711-0-0;
UNLOCK SCA
All the frequencies under observation must belong to the specified
band.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
UNSUCCESSFUL_OVERLAPPED_PERIODS
The accumulation time periods must not have intersections.
UNSUCCESSFUL_FREQUENCY_ALREADY_TRACED
The EICNF<nn> attributes must refer to different frequencies.
UNSUCCESSFUL_BCCH_BSIC_ALREADY_TRACED
The set bcchFrequency-netColorCode-bsColorCode has already
been traced in an other NMDLATT<nn> parameter.
FREQUENCY_NOT_ALLOWED
The frequencies traced in EICNF<nn> attributes must differ from
each other at least of more than 200 kHz.
UNSUCCESSFUL_INVALID_BCCH_FREQUENCY
The BCCH frequency specified in the NMDLATT<nn> attribute must
belong to an existent ADJC of the cell related to the SCA.
UNLOCK SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0;


1134 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42d9
SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA UNLOCK SCA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCAN:NAME=SCAN:0;
UPLOADREQ SCA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS SCA UPLOADREQ
SCA
Applicability:
Phase 2.
Visibility level: 3.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The selected object is not created.
UPLOADREQ SCA NAME=BTSM:0..199/BTS:0..23/SCA:0..0 ,DESTDIR=
,OVERWRITE=;


A30808-X3247-M230-6-7619

1135
CML:BSC SCA
Id:0900d805800d42d9
Command Description:
This command allows the user to upload the measure files from the BSC disk to the LMT
disk; the destination directory, the file name and the file overwriting (or not) must be
defined by the user.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
Uploadreq SCA:NAME=BTSM:0/BTS:0/SCA:0,DESTDIR="C:\Siemens",
FILE="Test_measure",OVERWRITE=YES;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before launching this command, the relative object instance must not
be in LOCKED state.
According to the configured stopDate field value, measurement data
collection is finished (i.e. the stopDate has been reached): the upload
cannot be executed since measures are not present in the BTS
equipment.
UPLOAD_ALREADY_IN_PROGRESS
Another UPLOAD procedure (manual or automatic) is already in
progress.


1136 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
SCANBSC
The SCANBSC (Scanner BSC) represents a scanning function on a BSC managed
object, and is able to report periodically the collected measurements.
ADD SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC ADD SCANBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBSC NAME=SCANBSC:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.


A30808-X3247-M230-6-7619

1137
CML:BSC SCANBSC
Id:0900d805800d42dd
Application Guidelines:
None.
Example of Command Execution:
Add SCANBSC:NAME=SCANBSC:0,MEASOBJLST=SINHOBSC | TMSGREC |
TMSHHDL;
CREATE SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC CREATE SCANBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the SCANBSC object. The
parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
CREATE SCANBSC NAME=SCANBSC:0..89 ,MEASLST= [,GRANP=]
[,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBSC:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL


1138 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
- Operation Failed
NACK CAUSES:
Application Guidelines:
PM generation report follows the next rules:
*** RESPONSE TO JOB 1 ***
Create Ack SCAN:
name = SCANBSC:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.


A30808-X3247-M230-6-7619

1139
CML:BSC SCANBSC
Id:0900d805800d42dd
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANBSC:NAME=SCANBSC:0,MEASLST=measList(DLKUNCON |
SINHOBSC | NRINHDFL | LOCAUTCH | NASPAVUN | DASPUNT |
BSCPRCLD),GRANP=MINUTES_5, START=1-Jan-2001, STOP=1-Dec-
2001,RECINT=daily(1-00-3-59&10-00-12-59&23-4-22-59&8-00-11-10&14-00-14-
59&15-00-18-59&20-00-21-59);
DELETE SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC DELETE SCANBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DELETE SCANBSC NAME=SCANBSC:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1140 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBSC:NAME=SCANBSC:0;
GET SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GET SCANBSC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBSC, the relative object instance must be in
LOCKED state.
GET SCANBSC NAME=SCANBSC:0..89 [,REQATTL= MEASLST ,GRANP
,START ,STOP ,RECINT ,LSUPDTIME ,LSLOTIME ,LSU-
LOTIME];
NAME: SCANBSC
MEASLIST: measureList
GRANP: granularityPeriod
START: startDate


A30808-X3247-M230-6-7619

1141
CML:BSC SCANBSC
Id:0900d805800d42dd
GET SCANBSC BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANBSC BASICS
None.
Example of Command Execution:
Get SCANBSC:NAME=SCANBSC:0,REQATTL=MEASLST&GRANP&
START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANBSC BASICS
Get SCANBSC BASICS:NAME=SCANBSC:0;
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBSC
MEASLIST: measureList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1142 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
GET SCANBSC BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GET SCANBSC BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBSC
Application Guidelines:
See GET SCANBSC
Example of Command Execution:
See GET SCANBSC
GET SCANBSC STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GET SCANBSC STAT
Applicability:
Phase 2.
Visibility level: 0.
GET SCANBSC
BASICS
NAME=SCANBSC:0..89;
GET SCANBSC STAT NAME=SCANBSC:0..89;


A30808-X3247-M230-6-7619

1143
CML:BSC SCANBSC
Id:0900d805800d42dd
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBSC object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANBSC STAT:NAME=SCANBSC:0;
GETCURRENTVALUES SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC GETCURRENTVALUES
SCANBSC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVAL-
UES SCANBSC
NAME=SCANBSC:0..89;


1144 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANBSC:NAME=SCANBSC:0;
LOCK SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC LOCK SCANBSC
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANBSC NAME=SCANBSC:0..89;


A30808-X3247-M230-6-7619

1145
CML:BSC SCANBSC
Id:0900d805800d42dd
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBSC:NAME=SCANBSC:0;
REMOVE SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC REMOVE SCANBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANBSC NAME=SCANBSC:0..89 ,MEASOBJLST=;


1146 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBSC:NAME=SCANBSC:0,MEASOBJLST=RFSUBUN;
SET SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC SET SCANBSC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the SCANBSC objct. The parameter
specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBSC NAME=SCANBSC:0..89 [,MEASLST=] [,GRANP=]
[,START=] [,STOP=] [,RECINT=];


A30808-X3247-M230-6-7619

1147
CML:BSC SCANBSC
Id:0900d805800d42dd
MEASLST measureList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBSC:
name = SCANBSC:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
Start date > stop date.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
Actual date > stop date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
Period start is not a multiple of granularity.
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.


1148 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42dd
SCANBSC
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Set SCANBSC:NAME=SCANBSC:0,MEASLST=allMeas(0),GRANP=MINUTES_60,
START=1-Jan-2001,STOP=1-Dec-2001,RECINT=all(0);
UNLOCK SCANBSC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBSC UNLOCK SCANBSC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBSC:NAME=SCANBSC:0;
UNLOCK SCANBSC NAME=SCANBSC:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1149
CML:BSC SCANBTS
Id:0900d805800d42e0
SCANBTS
The SCANBTS (Scanner BTS) is a scanning function on a specific set of BTS managed
objects, and is able to report periodically the collected measurements; the raw data are
collected at BSC.
ADD SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS ADD SCANBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBTS NAME=SCANBTS:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_WRONG_GRANULARITY
With MEASLIST=measlist(MBTCHCHT) the GRANP must be at least
MINUTE_15.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
WRONG_LIST_OF_MEASURE


1150 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTS:NAME=SCANBTS:0,MEASOBJLST=measList(NRFLSDCC |
SINTHITA | TACCBPRO);
CREATE SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS CREATE SCANBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the SCANBTS object. The
parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
Trying to add a measure already present inside scanner measures
list.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANBTS NAME=SCANBTS:0..89 ,MEASLST= ,OBJLST= [,GRANP=]
[,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST


A30808-X3247-M230-6-7619

1151
CML:BSC SCANBTS
Id:0900d805800d42e0
- Operation Failed
NACK CAUSES:
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTS:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTS:
name = SCANBTS:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_WRONG_GRANULARITY
With MEASLIST=allMeas(0) or MEASLIST=measlist(MBTCHCHT)
GRANP must be at least MINUTE_15.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains more times the same object.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION


1152 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANBTS:NAME=SCANBTS:0,MEASLST=allMeas(0),
OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=1-Jan-2001,
STOP=2-Feb-2002,RECINT=all(0);
DELETE SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS DELETE SCANBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANBTS NAME=SCANBTS:0..89;
Successful
***INFORMATION***


A30808-X3247-M230-6-7619

1153
CML:BSC SCANBTS
Id:0900d805800d42e0
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTS:NAME=SCANBTS:0;
GET SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GET SCANBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBTS, the relative object instance must be in
LOCKED state.
GET SCANBTS NAME=SCANBTS:0..89 [,REQATTL= MEASLST ,OBJLST
,GRANP ,START ,STOP ,RECINT ,LSUPDTIME ,LSLO-
TIME ,LSULOTIME];


1154 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANBTS BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
NAME: SCANBTS
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTS
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1155
CML:BSC SCANBTS
Id:0900d805800d42e0
GET SCANBTS BASICS
None.
Example of Command Execution:
Get SCANBTS:NAME=SCANBTS:0,REQATTL=MEASLST&OBJLST&GRANP&
START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANBTS BASICS
Get SCANBTS BASICS:NAME=SCANBTS:0;
GET SCANBTS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GET SCANBTS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTS
Application Guidelines:
See GET SCANBTS
GET SCANBTS
BASICS
NAME=SCANBTS:0..89;


1156 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
Example of Command Execution:
See GET SCANBTS
GET SCANBTS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GET SCANBTS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTS object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANBTS STAT:NAME=SCANBTS:0;
GET SCANBTS STAT NAME=SCANBTS:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1157
CML:BSC SCANBTS
Id:0900d805800d42e0
GETCURRENTVALUES SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS GETCURRENTVALUES
SCANBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
GETCURRENTVAL-
UES SCANBTS
NAME=SCANBTS:0..89 ,MONOBJ=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID


1158 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANBTS:NAME=SCANBTS:0, OBJ=BTSM:0/BTS:2;
LOCK SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS LOCK SCANBTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANBTS NAME=SCANBTS:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1159
CML:BSC SCANBTS
Id:0900d805800d42e0
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTS:NAME=SCANBTS:0;
REMOVE SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS REMOVE SCANBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
SUCCESSFUL
- Operation Failed
NACK CAUSES:
REMOVE SCANBTS NAME=SCANBTS:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.


1160 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTS:NAME=SCANBTS:0,MEASOBJLST=measList(NRFLSDCC);
SET SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS SET SCANBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the SCANBTS object.
The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBTS NAME=SCANBTS:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBTS:
name = SCANBTS:<istn>
commandResponse = SUCCESSFUL


A30808-X3247-M230-6-7619

1161
CML:BSC SCANBTS
Id:0900d805800d42e0
- Operation Failed
NACK CAUSES:
Application Guidelines:
PM generation report follows the next rules:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_WRONG_GRANULARITY
With MEASLIST=allMeas(0) or MEASLIST=measlist(MBTCHCHT)
GRANP must be at least MINUTE_15.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains more times the same object.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.


1162 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e0
SCANBTS
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Set SCANBTS:NAME=SCANBTS:0,MEASLST=allMeas(0),OBJLST=selfAdapting(0),
GRANP=MINUTES_15,START=1-Jan-2001,STOP=1-Jan-2002,RECINT=all(0);
UNLOCK SCANBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTS UNLOCK SCANBTS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBTS:NAME=SCANBTS:0;
UNLOCK SCANBTS NAME=SCANBTS:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1163
CML:BSC SCANBTSE
Id:0900d805800d42e4
SCANBTSE
The SCANBTSE (Scanner BTSE) represents a scanning function on a specific set of
BTS managed objects, and is able to report periodically the collected measurements;
the raw data are collected at BTSE and forwarded to BSC.
ADD SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE ADD SCANBTSE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful.
- Operation Failed
NACK CAUSES:
ADD SCANBTSE NAME=SCANBTSE:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in another scanner.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.
UNSUCCESSFUL_LIST_OF_OBJECT


1164 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e4
SCANBTSE
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTSE:NAME=SCANBTSE:0,MEASOBJLST=1-1&0-3;
CREATE SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE CREATE SCANBTSE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the SCANBTS object. The
parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANBTSE NAME=SCANBTSE:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTSE:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED


A30808-X3247-M230-6-7619

1165
CML:BSC SCANBTSE
Id:0900d805800d42e4
- Operation Failed
NACK CAUSES:
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTSE:
name = SCANBTSE:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).


1166 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e4
SCANBTSE
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Create SCANBTSE:NAME=SCANBTSE:0,MEASLST=measList(NINVRACH),
OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001,
STOP=31-Dec-2001,RECINT=weekly((suPeriod((5-0-7-59))-moNoSched(0)-tuN-
oSched(0)-wePeriod((3-0-9-59))-thNoSched(0)--saNoSched(0)));
DELETE SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE DELETE SCANBTSE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANBTSE NAME=SCANBTSE:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA


A30808-X3247-M230-6-7619

1167
CML:BSC SCANBTSE
Id:0900d805800d42e4
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTSE:NAME=SCANBTSE:0;
GET SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE GET SCANBTSE
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBTSE, the relative object instance must be in
LOCKED state.
GET SCANBTSE NAME=SCANBTSE:0..89 [,REQATTL= MEASLST ,OBJLST
,GRANP ,START ,STOP ,RECINT ,LSUPDTIME ,LSLO-
TIME ,LSULOTIME];


1168 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e4
SCANBTSE
System Responses:
- Operation Completed
GET SCANBTSE BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
GET SCANBTSE BASICS
None.
NAME: SCANBTSE
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTSE
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1169
CML:BSC SCANBTSE
Id:0900d805800d42e4
Example of Command Execution:
Get SCANBTSE:NAME=SCANBTSE:0,REQATTL=MEASLST&OBJLST&GRANP&
START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANBTSE BASICS
Get SCANBTSE BASICS:NAME=SCANBTSE:0;
GET SCANBTSE BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE GET SCANBTSE
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTSE
Application Guidelines:
See GET SCANBTSE
Example of Command Execution:
See GET SCANBTSE
GET SCANBTSE
BASICS
NAME=SCANBTSE:0..89;


1170 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e4
SCANBTSE
GET SCANBTSE STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE GET SCANBTSE STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTSE object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANBTSE STAT:NAME=SCANBTSE:0;
LOCK SCANBTSE
GET SCANBTSE STAT NAME=SCANBTSE:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK SCANBTSE NAME=SCANBTSE:0..89;


A30808-X3247-M230-6-7619

1171
CML:BSC SCANBTSE
Id:0900d805800d42e4
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE LOCK SCANBTSE
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTSE:NAME=SCANBTSE:0;
REMOVE SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE REMOVE SCANBTSE
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANBTSE NAME=SCANBTSE:0..89 ,MEASOBJLST=;


1172 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e4
SCANBTSE
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTSE:NAME=SCANBTSE:0,MEASOBJLST=0-0;
SET SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE SET SCANBTSE
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBTSE NAME=SCANBTSE:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];


A30808-X3247-M230-6-7619

1173
CML:BSC SCANBTSE
Id:0900d805800d42e4
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the SCANBTSE object.
The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBTSE:
name = SCANBTSE:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT


1174 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e4
SCANBTSE
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Set SCANBTSE:NAME=SCANBTSE:0,MEASLST=measList(AMRCHDIS),
OBJLST=selfAdapting(0),GRANP=MINUTES_15,START=22-Mar-2001,
STOP=31-Jun-2002,RECINT=all(0);
UNLOCK SCANBTSE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSE UNLOCK SCANBTSE
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
UNLOCK SCANBTSE NAME=SCANBTSE:0..89;


A30808-X3247-M230-6-7619

1175
CML:BSC SCANBTSE
Id:0900d805800d42e4
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBTSE:NAME=SCANBTSE:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1176 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
SCANBTSIHO
The SCANBTSIHO (Scanner BTS Incoming HandOver) represents a scanning function
on a specific set of origination/destination cells pairs involved in incoming handovers,
and is able to report periodically the collected measurements; raw data are collected at
BSC.
ADD SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO ADD SCANBTSIHO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBTSIHO NAME=SCANBTSIHO:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.
UNSUCCESSFUL_LIST_OF_OBJECT


A30808-X3247-M230-6-7619

1177
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTSIHO:NAME=SCANBTSIHO:0,MEASOBJLST=(0-0)-selfAdapting(0);
CREATE SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO CREATE SCAN-
BTSIHO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the SCANNER of BTS Incoming
Handover class. The parameters specify the values for the scheduling and reporting
activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
The object list contains the same target BTS more times.
On a single adjacent list the same BTS object is present more times.
It is not possible to add an adjacents list when the adjacents list is in
selfAdapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANBTSIHO NAME=SCANBTSIHO:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST


1178 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
- Operation Failed
NACK CAUSES:
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTSIHO:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTSIHO:
name = SCANBTSIHO:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in
an other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same BTS object is present more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION


A30808-X3247-M230-6-7619

1179
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANBTSIHO:NAME=SCANBTSIHO:0,MEASLST=allMeas(0),
OBJLST=(0-0)-selfAdapting(0)&(0-1)-selfAdapting(0),GRANP=MINUTES_60,
START=1-Jan-2001,STOP=31-Dec-2002,RECINT=all(0);
DELETE SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO DELETE SCAN-
BTSIHO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of
granularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANBTSIHO NAME=SCANBTSIHO:0..89;
Successful


1180 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTSIHO:NAME=SCANBTSIHO:0;
GET SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO GET SCANBTSIHO
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
GET SCANBTSIHO NAME=SCANBTSIHO:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


A30808-X3247-M230-6-7619

1181
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANBTSIHO BASICS
- Operation Failed
NACK CAUSES:
NAME: SCANBTSIHO
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTSIHO
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1182 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
Application Guidelines:
None.
GET SCANBTSIHO BASICS
None.
Example of Command Execution:
Get SCANBTSIHO:NAME=SCANBTSIHO:0,REQATTL=MEASLST&OBJLST&
GRANP&START&STOP&RECINT&LSUPDTIME&LSLOTIME&
LSULOTIME;
GET SCANBTSIHO BASICS
Get SCANBTSIHO BASICS:NAME=SCANBTSIHO:0;
GET SCANBTSIHO BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO GET SCANBTSIHO
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTSIHO
GET SCANBTSIHO
BASICS
NAME=SCANBTSIHO:0..89;


A30808-X3247-M230-6-7619

1183
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
Application Guidelines:
See GET SCANBTSIHO
Example of Command Execution:
See GET SCANBTSIHO
GET SCANBTSIHO STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO GET SCANBTSIHO
STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTSIHO object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANBTSIHO
STAT
NAME=SCANBTSIHO:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1184 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
Example of Command Execution:
Get SCANBTSIHO STAT:NAME=SCANBTSIHO:0;
GETCURRENTVALUES SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO GETCURRENTVAL-
UES SCANBTSIHO
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
LISOFMONOBJS listOfMonitoredObjects
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
GETCURRENTVAL-
UES SCANBTSIHO
NAME=SCANBTSIHO:0..89 ,LISOFMONOBJS=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.


A30808-X3247-M230-6-7619

1185
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANBTSIHO:NAME=SCANBTSIHO:0, OBJ=BTSM:0/BTS:2-
BTSM:3/BTS:2;
LOCK SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO LOCK SCANBTSIHO
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_WRONG_MEID
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANBTSIHO NAME=SCANBTSIHO:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1186 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTSIHO:NAME=SCANBTSIHO:0;
REMOVE SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO REMOVE SCAN-
BTSIHO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
REMOVE SCAN-
BTSIHO
NAME=SCANBTSIHO:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT


A30808-X3247-M230-6-7619

1187
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTSIHO:NAME=SCANBTSIHO:0,
MEASOBJLST=(0-0)-selfAdapting(0);
SET SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO SET SCANBTSIHO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the SCANNER of BTS Incoming
Handover class. The parameter specify the values for the scheduling and reporting
activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBTSIHO NAME=SCANBTSIHO:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***


1188 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
- Operation Failed
NACK CAUSES:
Set Ack SCANBTSIHO:
name = SCANBTSIHO:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same BTS object is present more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
UNSUCCESSFUL_TIMEFRAME_INCORRECT


A30808-X3247-M230-6-7619

1189
CML:BSC SCANBTSIHO
Id:0900d805800d42e7
Application Guidelines:
1. When a Restart of BSC is done, the Performance Measurements Data collected in
the last granularity are not significant.
2. The measurements have to be applied to already equipped object instances.
Example of Command Execution:
Set SCANBTSIHO:NAME=SCANBTSIHO:0,MEASLST=measList(AININIRH),
OBJLST=(0-0)-selfAdapting(0),GRANP=MINUTES_60,START=22-Dec-2001,
STOP=5-Apr-2003,RECINT=all(0);
UNLOCK SCANBTSIHO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSIHO UNLOCK SCAN-
BTSIHO
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNLOCK SCAN-
BTSIHO
NAME=SCANBTSIHO:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1190 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42e7
SCANBTSIHO
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBTSIHO:NAME=SCANBTSIHO:0;


A30808-X3247-M230-6-7619

1191
CML:BSC SCANBTSM
Id:0900d805800d42f0
SCANBTSM
The SCANBTSM (Scanner BTSM) represents a scanning function on a specific set of
BTSM managed objects, and is able to report periodically the collected measurements;
the raw data are collected at BTSE and forwarded to BSC.
ADD SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM ADD SCANBTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBTSM NAME=SCANBTSM:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
UNSUCCESSFUL_MEMORY_CORRUPTED


1192 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f0
SCANBTSM
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTSM:NAME=SCANBTSM:0,MEASOBJLST=LAYER1ABIS;
CREATE SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM CREATE SCANBTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the SCANBTSM object.
The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
Memory not available.
WRONG_LIST_OF_MEASURE
MEASLIST contains other measure besides BTSEPRLD
MEASLIST contains other measure besides IFRMABIS
CREATE SCANBTSM NAME=SCANBTSM:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTSM:istn


A30808-X3247-M230-6-7619

1193
CML:BSC SCANBTSM
Id:0900d805800d42f0
- Operation Failed
NACK CAUSES:
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTSM:
name = SCANBTSM:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
MEASLIST contains other measure besides BTSEPRLD
MEASLIST contains other measure besides IFRMABIS
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START


1194 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f0
SCANBTSM
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Create SCANBTSM:NAME=SCANBTSM:0,MEASLST=allMeas(0),
OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-1-2001,STOP=31-12-
2003, RECINT=all(0);
DELETE SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM DELETE SCANBTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANBTSM NAME=SCANBTSM:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit


A30808-X3247-M230-6-7619

1195
CML:BSC SCANBTSM
Id:0900d805800d42f0
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTSM:NAME=SCANBTSM:0;
GET SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM GET SCANBTSM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBTSM, the relative object instance must be in
LOCKED state.
GET SCANBTSM NAME=SCANBTSM:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


1196 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f0
SCANBTSM
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANBTSM BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANBTSM BASICS
None.
NAME: SCANBTSM
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTSM
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1197
CML:BSC SCANBTSM
Id:0900d805800d42f0
Example of Command Execution:
Get SCANBTSM:NAME=SCANBTSM:0,REQATTL=MEASLST&OBJLST&GRANP&
START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANBTSM BASICS
Get SCANBTSM BASICS:NAME=SCANBTSM:0;
GET SCANBTSM BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM GET SCANBTSM
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTSM
Application Guidelines:
See GET SCANBTSM
Example of Command Execution:
See GET SCANBTSM
GET SCANBTSM
BASICS
NAME=SCANBTSM:0..89;


1198 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f0
SCANBTSM
GET SCANBTSM STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM GET SCANBTSM STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTSM object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANBTSM STAT:NAME=SCANBTSM:0;
LOCK SCANBTSM
GET SCANBTSM STAT NAME=SCANBTSM:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK SCANBTSM NAME=SCANBTSM:0..89;


A30808-X3247-M230-6-7619

1199
CML:BSC SCANBTSM
Id:0900d805800d42f0
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM LOCK SCANBTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTSM:NAME=SCANBTSM:0;
REMOVE SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM REMOVE SCANBTSM
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANBTSM NAME=SCANBTSM:0..89 ,MEASOBJLST=;


1200 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f0
SCANBTSM
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTSM:NAME=SCANBTSM:0,MEASOBJLST=1&1;
SET SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM SET SCANBTSM
Applicability:
Phase 2.
Visibility level: 2.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain almost one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBTSM NAME=SCANBTSM:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];


A30808-X3247-M230-6-7619

1201
CML:BSC SCANBTSM
Id:0900d805800d42f0
Command Description:
This command sets the configuration of instance of the SCANBTSM object. The
parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBTSM:
name = SCANBTSM:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
MEASLIST contains other measure besides BTSEPRLD
MEASLIST contains other measure besides IFRMABIS
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT


1202 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f0
SCANBTSM
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Set SCANBTSM:NAME=SCANBTSM:0,MEASLST=measList(IFRMABIS),
OBJLST=selfAdapting(0),GRANP=MINUTES_60,START=1-1-2001,STOP=5-12-2003,
RECINT=all(0);
UNLOCK SCANBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSM UNLOCK SCANBTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
UNLOCK SCANBTSM NAME=SCANBTSM:0..89;


A30808-X3247-M230-6-7619

1203
CML:BSC SCANBTSM
Id:0900d805800d42f0
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBTSM:NAME=SCANBTSM:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1204 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
SCANBTSOHOI
The SCANBTSOHOI (Scanner BTS Outgoing HandOver to Internal cells) represents a
scanning function on a specific set of origination/internal-destination cells pairs involved
in outgoing handovers, and is able to report periodically the collected measurements;
the raw data are collected at BSC.
ADD SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI ADD SCANBTSO-
HOI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBTSOHOI NAME=SCANBTSOHOI:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.


A30808-X3247-M230-6-7619

1205
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTSOHOI:NAME=SCANBTSOHOI:0,MEASOBJLST=measList(SOUINIRH
| AOUINIRH);
CREATE SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI CREATE SCANBT-
SOHOI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner providing
measurement related to BTS outgoing handovers to internal cells. The parameters
specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same ADJC object is present more
times.
It is not possible to add an adjacents list when the adjacents list is in
selfAdapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANBTSO-
HOI
NAME=SCANBTSOHOI:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;


1206 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTSOHOI:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTSOHOI:
name = SCANBTSOHOI:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same ADJC object is present more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.


A30808-X3247-M230-6-7619

1207
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANBTSOHOI:NAME=SCANBTSOHOI:0,MEASLST=allMeas(0),
OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001,
STOP=31-Dec-2001,RECINT=all(0);
DELETE SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI DELETE SCANBT-
SOHOI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANBTSO-
HOI
NAME=SCANBTSOHOI:0..89;


1208 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTSOHOI:NAME=SCANBTSOHOI:0;
GET SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GET SCANBTSO-
HOI
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBTSHOI, the relative object instance must be
in LOCKED state.
GET SCANBTSOHOI NAME=SCANBTSOHOI:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


A30808-X3247-M230-6-7619

1209
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANBTSOHOI BASICS
NAME: SCANBTSOHOI
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTSOHOI
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime


1210 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANBTSOHOI BASICS
None.
Example of Command Execution:
Get SCANBTSOHOI:NAME=SCANBTSOHOI:0,REQATTL=MEASLST&OBJLST&
GRANP&START&STOP&RECINT&LSUPDTIME&LSLOTIME&
LSULOTIME;
GET SCANBTSOHOI BASICS
Get SCANBTSOHOI BASICS:NAME=SCANBTSOHOI:0;
GET SCANBTSOHOI BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GET SCANBTSO-
HOI BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET SCANBTSOHOI
BASICS
NAME=SCANBTSOHOI:0..89;


A30808-X3247-M230-6-7619

1211
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTSOHOI
Application Guidelines:
See GET SCANBTSOHOI
Example of Command Execution:
See GET SCANBTSOHOI
GET SCANBTSOHOI STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GET SCANBTSO-
HOI STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTSOHOI object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
GET SCANBTSOHOI
STAT
NAME=SCANBTSOHOI:0..89;


1212 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANBTSOHOI STAT:NAME=SCANBTSOHOI:0;
GETCURRENTVALUES SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI GETCUR-
RENTVALUES SCANBTSOHOI
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVAL-
UES SCANBTSOHOI
NAME=SCANBTSOHOI:0..89 ,MONOBJ=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

1213
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANBTSOHOI:NAME=SCANBTSOHOI:0, OBJ=BTSM:0/BTS:2-
BTSM:3/ADJC:2;
LOCK SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI LOCK SCANBTSO-
HOI
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANBTSOHOI NAME=SCANBTSOHOI:0..89;


1214 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTSOHOI:NAME=SCANBTSOHOI:0;
REMOVE SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI REMOVE SCAN-
BTSOHOI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANBTSO-
HOI
NAME=SCANBTSOHOI:0..89 ,MEASOBJLST=;


A30808-X3247-M230-6-7619

1215
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTSOHOI:NAME=SCANBTSOHOI:0,
MEASOBJLST=measList(AOUINIRH | UNINHOIE);
SET SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI SET SCANBTSO-
HOI
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration instance of the scanner providing measurement
related to BTS outgoing handovers to internal cells. The parameters specify the values
for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBTSOHOI NAME=SCANBTSOHOI:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];


1216 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBTSOHOI:
name = SCANBTSOHOI:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same ADJC object is present more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.


A30808-X3247-M230-6-7619

1217
CML:BSC SCANBTSOHOI
Id:0900d805800d42f3
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Set SCANBTSOHOI:NAME=SCANBTSOHOI:0,MEASLST=allMeas(0),
OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001,
STOP=3-Mar-2002,RECINT=all(0);
UNLOCK SCANBTSOHOI
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOI UNLOCK SCANBT-
SOHOI
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
UNLOCK SCANBTSO-
HOI
NAME=SCANBTSOHOI:0..89;
ALREADY_IN_TARGET_STATE


1218 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f3
SCANBTSOHOI
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBTSOHOI:NAME=SCANBTSOHOI:0;
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1219
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
SCANBTSOHON
The SCANBTSOHON (Scanner BTS Outgoing HandOver to Neighbour cells)
represents a scanning function on a specific set of origination/neighbour-destination
cells pairs involved in outgoing handovers, and is able to report periodically the collected
measurements; the raw data are collected at BSC.
ADD SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON ADD SCANBTSO-
HON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner previ-
ously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBTSOHON NAME=SCANBTSOHON:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already config-
ured in an other scanner.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.


1220 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTSOHON:NAME=SCANBTSOHON:0,
MEASOBJLST=measList(SUINBHDO);
CREATE SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON CREATE SCAN-
BTSOHON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner providing
measurement related to BTS outgoing handovers to neighbour cells. The parameters
specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same TGTBTS object is present more
times.
It is not possible to add an adjacents list when the adjacents list is in
selfAdapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANBTSO-
HON
NAME=SCANBTSOHON:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;


A30808-X3247-M230-6-7619

1221
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTSOHON:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTSOHON:
name = SCANBTSOHON:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same TGTBTS object is present more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.


1222 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANBTSOHON:NAME=SCANBTSOHON:0,MEASLST=allMeas(0),
OBJLST=(1-1)-selfAdapting(0)&(2-1)-selfAdapting(0)&(4-22)-selfAdapting(0),
GRANP=MINUTES_60,START=1-Jan-2001,STOP=31-Dec-2001,RECINT=all(0);
DELETE SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON DELETE SCAN-
BTSOHON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANBTSO-
HON
NAME=SCANBTSOHON:0..89;


A30808-X3247-M230-6-7619

1223
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTSOHON:NAME=SCANBTSOHON:0;
GET SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GET SCANBTSO-
HON
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBTSOHON, the relative object instance must
be in LOCKED state.
GET SCANBTSOHON NAME=SCANBTSOHON:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


1224 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANBTSOHON BASICS
NAME: SCANBTSOHON
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTSOHON
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime


A30808-X3247-M230-6-7619

1225
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANBTSOHON BASICS
None.
Example of Command Execution:
Get SCANBTSOHON:NAME=SCANBTSOHON:0,REQATTL=MEASLST&OBJLIST&
GRANP& START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME;
GET SCANBTSOHON BASICS
Get SCANBTSOHON BASICS:NAME=SCANBTSOHON:0;
GET SCANBTSOHON BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GET SCANBTSO-
HON BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET SCANBTSOHON
BASICS
NAME=SCANBTSOHON:0..89;


1226 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTSOHON
Application Guidelines:
See GET SCANBTSOHON
Example of Command Execution:
See GET SCANBTSOHON
GET SCANBTSOHON STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GET SCANBTSO-
HON STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTSOHON object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
GET SCANBTSOHON
STAT
NAME=SCANBTSOHON:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

1227
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
Application Guidelines:
None.
Example of Command Execution:
Get SCANBTSOHON STAT:NAME=SCANBTSOHON:0;
GETCURRENTVALUES SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON GETCUR-
RENTVALUES SCANBTSOHON
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
The object instance must be already equipped.
GETCURRENTVAL-
UES SCANBTSOHON
NAME=SCANBTSOHON:0..89 ,MONOBJ=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT


1228 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANBTSOHON:NAME=SCANBTSOHON:0, OBJ=BTSM:0/BTS:2-
BTSM:3/ADJC:3;
LOCK SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON LOCK SCANBT-
SOHON
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANBTSOHON NAME=SCANBTSOHON:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.


A30808-X3247-M230-6-7619

1229
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTSOHON:NAME=SCANBTSOHON:0;
REMOVE SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON REMOVE SCAN-
BTSOHON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANBTSO-
HON
NAME=SCANBTSOHON:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.


1230 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTSOHON:NAME=SCANBTSOHON:0,
MEASOBJLST=measList(NRUNINHD);
SET SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON SET SCANBTSO-
HON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the scanner providing measurement
related to BTS outgoing handovers to neighbour cells. The parameters specify the
values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANBTSOHON NAME=SCANBTSOHON:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];


A30808-X3247-M230-6-7619

1231
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBTSOHON:
name = SCANBTSOHON:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same target BTS more times.
On a single adjacent list the same TGTBTS object is present more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.


1232 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f6
SCANBTSOHON
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Set SCANBTSOHON:NAME=SCANBTSOHON:0,MEASLST=measList(ATINBHDO |
SUINBHDO | NRUNINHD),OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_5,
START=1-Feb-2001,STOP=2-Mar-2002,RECINT=all(0);
UNLOCK SCANBTSOHON
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHON UNLOCK SCAN-
BTSOHON
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNLOCK SCANBTSO-
HON
NAME=SCANBTSOHON:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1233
CML:BSC SCANBTSOHON
Id:0900d805800d42f6
Example of Command Execution:
Unlock SCANBTSOHON:NAME=SCANBTSOHON:0;


1234 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
SCANBTSOHOS
The SCANBTSOHOS represents a scanning function on a specific set of
origination/neighbour-destination cell pairs involved in outgoing handovers from GSM to
UMTS system, and is able to report periodically the collected measurements; the raw
data are collected at BSC.
ADD SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS ADD SCANBTSO-
HOS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANBTSOHOS NAME=SCANBTSOHOS:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the objList list.
WRONG_LIST_OF_MEASURE
A measure cannot be duplicated.
Measure not present.


A30808-X3247-M230-6-7619

1235
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
Application Guidelines:
None.
Example of Command Execution:
Add SCANBTSOHOS:NAME=SCANBTSOHOS:0,
MEASOBJLST=measList(ATOISHDO);
CREATE SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS CREATE SCAN-
BTSOHOS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner providing
measurement related to BTS outgoing handovers from GSM to UMTS system.
The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
CREATE SCANBTSO-
HOS
NAME=SCANBTSOHOS:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANBTSOHOS:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED


1236 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
- Operation Failed
NACK CAUSES:
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANBTSOHOS:
name = SCANBTSOHOS:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
WRONG_LIST_OF_MEASURE
The measures list cannot be empty.
A measure cannot be duplicated.
Measure not present or only one measure within database.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The global number of equipped scanner objects must not exceed a fixed
maximum number (90).
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the OBJLST list.
UNSUCCESSFUL_INVALID_DATE
The start date or the stop date are incorrect.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START


A30808-X3247-M230-6-7619

1237
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
Application Guidelines:
None.
Example of Command Execution:
Create SCANBTSOHOS:NAME=SCANBTSOHOS:0,MEASLST=allMeas(0),
OBJLST=(1-1)-selfAdapting(0)&(2-1)-selfAdapting(0)&(4-22)-selfAdapting(0),
GRANP=MINUTES_60,START=1-Jan-2001,STOP=31-Dec-2001,RECINT=all(0);
DELETE SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS DELETE SCANBT-
SOHOS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
DELETE SCANBTSO-
HOS
NAME=SCANBTSOHOS:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA


1238 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANBTSOHOS:NAME=SCANBTSOHOS:0;
GET SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GET SCANBTSO-
HOS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANBTSOHOS, the relative object instance must
be in LOCKED state.
GET SCANBTSOHOS NAME=SCANBTSOHOS:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


A30808-X3247-M230-6-7619

1239
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
System Responses:
- Operation Completed
GET SCANBTSOHOS BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANBTSOHOS BASICS
None.
NAME: SCANBTSOHON
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANBTSOHOS
MEASLST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1240 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
Example of Command Execution:
Get SCANBTSOHOS:NAME=SCANBTSOHOS:0,REQATTL=MEASLST&OBJLIST&
GRANP& START&STOP&RECINT&LSUPDTIME&LSLOTIME& LSULOTIME;
GET SCANBTSOHOS BASICS
Get SCANBTSOHOS BASICS:NAME=SCANBTSOHOS:0;
GET SCANBTSOHOS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GET SCANBTSO-
HOS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANBTSOHOS
Application Guidelines:
See GET SCANBTSOHOS
Example of Command Execution:
See GET SCANBTSOHOS
GET SCANBTSOHOS
BASICS
NAME=SCANBTSOHOS:0..89;


A30808-X3247-M230-6-7619

1241
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
GET SCANBTSOHOS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GET SCANBTSO-
HOS STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANBTSOHOS object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANBTSOHOS STAT:NAME=SCANBTSOHOS:0;
GET SCANBTSOHOS
STAT
NAME=SCANBTSOHOS:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1242 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
GETCURRENTVALUES SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS GETCUR-
RENTVALUES SCANBTSOHOS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
GETCURRENTVAL-
UES SCANBTSOHOS
NAME=SCANBTSOHOS:0..89 ,MONOBJ=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID


A30808-X3247-M230-6-7619

1243
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANBTSOHOS:NAME=SCANBTSOHOS:0, OBJ=BTSM:0/BTS:2-
BTSM:3/ADJ3G:2;
LOCK SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS LOCK SCANBT-
SOHOS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state LOCKED.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANBTSOHOS NAME=SCANBTSOHOS:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1244 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed, no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANBTSOHOS:NAME=SCANBTSOHOS:0;
REMOVE SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS REMOVE SCAN-
BTSOHOS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
REMOVE SCANBTSO-
HOS
NAME=SCANBTSOHOS:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT


A30808-X3247-M230-6-7619

1245
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
Application Guidelines:
None.
Example of Command Execution:
Remove SCANBTSOHOS:NAME=SCANBTSOHOS:0,
MEASOBJLST=measList(ATOISHDO);
SET SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS SET SCANBTSO-
HOS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the scanner providing measurement
related to BTS outgoing handovers from GSM to UMTS system. The parameters specify
the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
The same object instance cannot be repeated in the objList list.
SET SCANBTSOHOS NAME=SCANBTSOHOS:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANBTSOHOS:
name = SCANBTSOHOS:<istn>
commandResponse = SUCCESSFUL


1246 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42f9
SCANBTSOHOS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
WRONG_LIST_OF_MEASURE
The measures list cannot be empty.
A measure cannot be duplicated.
Measure not present or only one measure within database.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The global number of equipped scanner objects must not exceed a fixed
maximum number (90).
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the OBJLST list.
UNSUCCESSFUL_INVALID_DATE
The start date or the stop date are incorrect.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.


A30808-X3247-M230-6-7619

1247
CML:BSC SCANBTSOHOS
Id:0900d805800d42f9
Example of Command Execution:
Set SCANBTSOHOS:NAME=SCANBTSOHOS:0,MEASLST=measList(ATOISHDO |
SUOISHDO| UNOISHDO),OBJLST=(1-1)-selfAdapting(0),GRANP=MINUTES_5,
START=1-Feb-2001,STOP=2-Mar-2002,RECINT=all(0);
UNLOCK SCANBTSOHOS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANBTSOHOS UNLOCK SCAN-
BTSOHOS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state UNLOCKED.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANBTSOHOS:NAME=SCANBTSOHOS:0;
UNLOCK SCANBTSO-
HOS
NAME=SCANBTSOHOS:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1248 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
SCANCHAN
The SCANCHAN (Scanner Channel) represents a scanning function on a specific set of
CHAN objects, and is able to report periodically the collected measurements; the raw
data are collected at BTSE and forwarded to BSC.
ADD SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN ADD SCANCHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANCHAN NAME=SCANCHAN:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
Exceeded max number of objects.


A30808-X3247-M230-6-7619

1249
CML:BSC SCANCHAN
Id:0900d805800d42fc
Application Guidelines:
None.
Example of Command Execution:
Add SCANCHAN:NAME=SCANCHAN:43,MEASOBJLST=1-1-0-list(Chan2);
CREATE SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN CREATE SCANCHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SCANCHAN
objetc. The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
OBJLST objectList
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
No more than 10 TRXs of the same BTSM can be specified among
all SCANCHAN instances.
No more than 80 channels must be under measure among all
SCANCHAN instances.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANCHAN NAME=SCANCHAN:0..89 ,OBJLST= [,START=] [,STOP=]
,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANCHAN:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED


1250 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
- Operation Failed
NACK CAUSES:
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANCHAN:
name = SCANCHAN:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
No more than 10 TRXs of the same BTSM can be specified among all
SCANCHAN instances.
No more than 80 channels must be under measure among all SCANCHAN
instances.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD


A30808-X3247-M230-6-7619

1251
CML:BSC SCANCHAN
Id:0900d805800d42fc
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Create SCANCHAN:NAME=SCANCHAN:0,
OBJLST=0-0-0-list(chan7)&1-1-4-list(chan6),START=1-Jan-2001,
STOP=2-Feb-2002,RECINT=all(0);
DELETE SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN DELETE SCANCHAN
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANCHAN NAME=SCANCHAN:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA


1252 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANCHAN:NAME=SCANCHAN:0;
GET SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN GET SCANCHAN
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANCHAN, the relative object instance must be in
LOCKED state
GET SCANCHAN NAME=SCANCHAN:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


A30808-X3247-M230-6-7619

1253
CML:BSC SCANCHAN
Id:0900d805800d42fc
System Responses:
- Operation Completed
GET SCANCHAN BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANCHAN BASICS
None.
NAME: SCANCHAN
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANCHAN
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1254 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
Example of Command Execution:
Get SCANCHAN:NAME=SCANCHAN:0,REQATTL=MEASLST&OBJLIST&GRANP&
START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANCHAN BASICS
Get SCANCHAN BASICS:NAME=SCANCHAN:0;
GET SCANCHAN BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN GET SCANCHAN
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANCHAN
Application Guidelines:
See GET SCANCHAN
Example of Command Execution:
See GET SCANCHAN
GET SCANCHAN
BASICS
NAME=SCANCHAN:0..89;


A30808-X3247-M230-6-7619

1255
CML:BSC SCANCHAN
Id:0900d805800d42fc
GET SCANCHAN STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN GET SCANCHAN
STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANCHN object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANCHAN STAT:NAME=SCANCHAN:0;
LOCK SCANCHAN
GET SCANCHAN STAT NAME=SCANCHAN:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK SCANCHAN NAME=SCANCHAN:0..89;


1256 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN LOCK SCANCHAN
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANCHAN:NAME=SCANCHAN:0;
REMOVE SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN REMOVE SCANCHAN
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANCHAN NAME=SCANCHAN:0..89 ,MEASOBJLST=;


A30808-X3247-M230-6-7619

1257
CML:BSC SCANCHAN
Id:0900d805800d42fc
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANCHAN:NAME=SCANCHAN:0,MEASOBJLST=0-1-4-list(Chan1);
SET SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN SET SCANCHAN
Applicability:
Phase 2.
Visibility level: 2.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANCHAN NAME=SCANCHAN:0..89 [,OBJLST=] [,START=] [,STOP=]
[,RECINT=];


1258 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
Command Description:
This command sets the configuration of instance of the scanner of SCANCHAN object.
The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
OBJLST objectList
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANCHAN:
name = SCANCHAN:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
No more than 10 TRXs of the same BTSM can be specified among all
SCANCHAN instances.
No more than 80 channels must be under measure among all SCANCHAN
instances.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED


A30808-X3247-M230-6-7619

1259
CML:BSC SCANCHAN
Id:0900d805800d42fc
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Set SCANCHAN:NAME=SCANCHAN:0,OBJLST=1-1-1-allTch(0),
START=11-Dec-2001,STOP=2-Feb-2002,RECINT=all(0);
UNLOCK SCANCHAN
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCHAN UNLOCK SCANCHAN
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNLOCK SCANCHAN NAME=SCANCHAN:0..89;


1260 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42fc
SCANCHAN
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
UNLOCK SCANCHAN:NAME=SCANCHAN:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1261
CML:BSC SCANCO
Id:0900d805800d42ff
SCANCO
The SCANCO object is the scanner complex control and it is used to have a report of all
the scanner functions.
GETINFO SCANCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCO GETINFO SCANCO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve a list of the created scanners and for each scanner its
most important data.
The information provided in the report are the following:
The number of configured scanners
The current Performance Measurement logfile size
The current Performance Measurement temporary logfile size
The maximum Performance Measurement logfile size
The esteem of a daily usage which depends on the number and the attributes of
already configured SCAN objects
The automatic adaptation enabling
Scanner id
Measure class
Scanner states and statuses: AST, AVS
Granularity
A daily foreseen file size or a daily foreseen number of measurement reports
Start date
Stop date
Periodicity
Amount of objects defined
Automatic adaptation activation
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO SCANCO NAME=SCANCO:0..0;


1262 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ff
SCANCO
GETINFO SCANCO:NAME=SCANCO:0;
(* REPLAY OF THE BSC *)
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** RESPONSE TO JOB 1 ***
GETINFO REPORT ACK SCANCO:
NAME = SCANCO:0
SCANNER DATA VALUES:
NUMBER OF SCANNERS CONFIGURED: 3
CURRENT SIZE OF TMP FILE: 9 KBYTES
MAXIMUM SIZE OF LOG FILE: 42 KBYTES
SCANNER ATTRIBUTES LIST:
NAME: SCANBTS:3
ADMINISTRATIVE STATE: UNLOCKED
AVAILABILITY STATUS: NONE
GRANULARITY PERIOD: FIFTEEN_MIN
AUTOMATIC ADAPTION ACTIVATION: TRUE
START DATE: 01-JAN-1995
STOP DATE: 31-DEC-2099
PERIOD TYPE: ALWAYS_ACTIVE
NUMBER OF OBJECTS: 2
NUMBER OF MEASUREMENTS: 1
NAME: SCANBTS:4
ADMINISTRATIVE STATE: UNLOCKED
AVAILABILITY STATUS: NONE
GRANULARITY PERIOD: SIXTY_MIN
AUTOMATIC ADAPTION ACTIVATION: TRUE
START DATE: 31-JAN-1995
STOP DATE: 6-DEC-2099
PERIOD TYPE: WEEKLY_SCHED
NUMBER OF OBJECTS: 1
NUMBER OF MEASUREMENTS: 58
NAME: SCANBSC:12
ADMINISTRATIVE STATE: UNLOCKED
AVAILABILITY STATUS: NONE


A30808-X3247-M230-6-7619

1263
CML:BSC SCANCO
Id:0900d805800d42ff
GRANULARITY PERIOD: FIVE_MIN
AUTOMATIC ADAPTION ACTIVATION: TRUE
START DATE: 31-JAN-1995
STOP DATE: 6-DEC-2099
PERIOD TYPE: ALWAYS_ACTIVE
NUMBER OF OBJECTS: 1
NUMBER OF MEASUREMENTS: 1
- Operation Failed
GETINFO SCANCO NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack SCANCO:
name = SCANCO:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
Due to the amount of information to be provided, it may be required to produce several
reports.
Example of Command Execution:
Getinfo SCANCO:NAME=SCANCO:0;
UPLMEAS SCANCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCO UPLMEAS SCANCO
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
UPLMEAS SCANCO NAME=SCANCO:0..0 ,DESTDIR= ,OVERWRITE=;


1264 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d42ff
SCANCO
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows to upload, from BSC disk to LMT disk, the measure files.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
UPLMEAS SCANCO:NAME=SCANCO:0,DESTDIR="C:\Measure",FILE="General",
OVERWRITE=NO;
DIRECTORY_NOT_FOUND
FILE_NOT_FOUND
UPLOAD_ALREADY_IN_PROGRESS_NCK
The command is occurred when another UPLOAD procedure is in
progress.


A30808-X3247-M230-6-7619

1265
CML:BSC SCANCTRX
Id:0900d805800d4302
SCANCTRX
The SCANCTRX (Scanner Correlated TRX) represents a scanning function on a
specific set of TRX managed objects, and is able to report periodically the collected
measurements; the raw data are collected at BTSE and forwarded to BSC.
ADD SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX ADD SCANCTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANCTRX NAME=SCANCTRX:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEMORY_CORRUPTED


1266 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4302
SCANCTRX
Application Guidelines:
None.
Example of Command Execution:
Add SCANCTRX:NAME=SCANCTRX:0,MEASOBJLST=5-17-22;
CREATE SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX CREATE SCANCTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the scanner of SCANCTRX object. The
parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
OBJLST objectList
START startDate
STOP stopDate
RECINT recordingInterval
RXLVR rxLevRanges
TIMADVR timingAdvanceRanges
FER frameErasureRate
FERSERTYPE ferServiceType
System Responses:
- Operation Completed
Memory not available.
CREATE SCANCTRX NAME=SCANCTRX:0..89 ,OBJLST= [,START=] [,STOP=]
,RECINT= [,RXLVR=] [,TIMADVR=] [,FER=] [,FERSER-
TYPE=];
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANCTRX:
name = SCANCTRX:<istn>
commandResponse = SUCCESSFUL


A30808-X3247-M230-6-7619

1267
CML:BSC SCANCTRX
Id:0900d805800d4302
- Operation Failed
NACK CAUSES:
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_INVALID_ATTRIBUTES
RXLVR, TIMADVR, FER attributes values must be in ascendent order.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
UNSUCCESSFUL_TIMEFRAME_INCORRECT


1268 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4302
SCANCTRX
Example of Command Execution:
Create SCANCTRX:NAME=SCANCTRX:0,OBJLST=selfAdapting(0),
START=1-Jan-2001,STOP=1-Jan-2002,RECINT=all(0),RXLVR=7-15-23-31-39-47-55,
TIMADVR=1-2-3-4-5-6-7,FER=10-20-30-40-50-100-200,FERSERTYPE=TCH_FULL;
DELETE SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX DELETE SCANCTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
DELETE SCANCTRX NAME=SCANCTRX:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANCTRX, the relative object instance must be in
LOCKED state.


A30808-X3247-M230-6-7619

1269
CML:BSC SCANCTRX
Id:0900d805800d4302
Example of Command Execution:
Delete SCANCTRX:NAME=SCANCTRX:0;
GET SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX GET SCANCTRX
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
RXLVR rxLevRanges
TIMADVR timingAdvanceRanges
FER frameErasureRate
FERSERTYPE ferServiceType
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANCTRX NAME=SCANCTRX:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,RXLVR
,TIMADVR ,FER ,FERSERTYPE ,LSUPDTIME ,LSLOTIME
,LSULOTIME];
NAME: SCANCTRX
MEASLIST: measureList
GRANP: granularityPeriod
START: startDate


1270 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4302
SCANCTRX
GET SCANCTRX BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANCTRX BASICS
None.
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
RXLVR rxLevRanges
TIMADVR timingAdvanceRanges
FER frameErasureRate
FERSER-
TYPE
ferServiceType
NAME: SCANCTRX
MEASLIST: measureList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
RXLVR: rxLevRanges
TIMADVR: timingAdvanceRanges
FER: frameErasureRate
FERSERTYPE: ferServiceType
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1271
CML:BSC SCANCTRX
Id:0900d805800d4302
Example of Command Execution:
Get SCANCTRX:NAME=SCANCTRX:0,REQATTL=MEASLST&OBJLST&
GRANP&START&STOP&RECINT&RXLVR&TIMADVR&FER&
FERSERTYPE&LSUPDTIME&LSLOTIME& LSULOTIME;
GET SCANCTRX BASICS
Get SCANCTRX BASICS:NAME=SCANCTRX:0;
GET SCANCTRX BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX GET SCANCTRX
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
RXLVR rxLevRanges
TIMADVR timingAdvanceRanges
FER frameErasureRate
FERSERTYPE ferServiceType
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANCTRX
GET SCANCTRX
BASICS
NAME=SCANCTRX:0..89;


1272 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4302
SCANCTRX
Application Guidelines:
See GET SCANCTRX
Example of Command Execution:
See GET SCANCTRX
GET SCANCTRX STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX GET SCANCTRX STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANCTRX object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANCTRX STAT:NAME=SCANCTRX:0;
GET SCANCTRX STAT NAME=SCANCTRX:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1273
CML:BSC SCANCTRX
Id:0900d805800d4302
LOCK SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX LOCK SCANCTRX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANCTRX:NAME=SCANCTRX:0;
REMOVE SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX REMOVE SCANCTRX
LOCK SCANCTRX NAME=SCANCTRX:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REMOVE SCANCTRX NAME=SCANCTRX:0..89 ,MEASOBJLST=;


1274 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4302
SCANCTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANCTRX:NAME=SCANCTRX:0,MEASOBJLST=1-1-1;
SET SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX SET SCANCTRX
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANCTRX NAME=SCANCTRX:0..89 [,OBJLST=] [,START=] [,STOP=]
[,RECINT=] [,RXLVR=] [,TIMADVR=] [,FER=] [,FERSER-
TYPE=];


A30808-X3247-M230-6-7619

1275
CML:BSC SCANCTRX
Id:0900d805800d4302
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the scanner of SCANCTRX object.
The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
OBJLST objectList
START startDate
STOP stopDate
RECINT recordingInterval
RXLVR rxLevRanges
TIMADVR timingAdvanceRanges
FER frameErasureRate
FERSERTYPE ferServiceType
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANCTRX:
name = SCANCTRX:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_INVALID_ATTRIBUTES


1276 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4302
SCANCTRX
Application Guidelines:
Regarding Abis measurements, PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, no report is generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within START_DATE and STOP_DATE attributes values.
Example of Command Execution:
Set SCANCTRX:NAME=SCANCTRX:0,OBJLST=selfAdapting(0),
START=1-Jan-2001,STOP=1-Dec-2002,RECINT=all(0),RXLVR=7-15-23-31-39-47-55,
TIMADVR=1-2-3-4-5-6-7,FER=10-20-30-40-50-100-200,FERSERTYPE=TCH_FULL;
UNLOCK SCANCTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANCTRX UNLOCK SCANCTRX
Applicability:
Phase 2.
Visibility level: 1.
RXLVR, TIMADVR, FER attributes values must be in ascendent order.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
UNLOCK SCANCTRX NAME=SCANCTRX:0..89;


A30808-X3247-M230-6-7619

1277
CML:BSC SCANCTRX
Id:0900d805800d4302
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANCTRX:NAME=SCANCTRX:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1278 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
SCANFBTSM
The SCANFBTSM represents a scanning class that collects measures per BTSM in
order to support EDGE performances, and is able to report periodically the collected
measurements; the raw data are collected at BSC.
ADD SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM ADD SCANFBTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANFBTSM NAME=SCANFBTSM:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
The measure list cannot be empty.
A measure cannot be duplicated.
Measure not present or only one measure within database.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured
for another SCANFBTSM object or the same measure type is
repeated in the measure list of a SCANFBTSM instance.


A30808-X3247-M230-6-7619

1279
CML:BSC SCANFBTSM
Id:0900d805800d4305
Application Guidelines:
None.
Example of Command Execution:
Add SCANFBTSM:NAME=SCANFBTSM:0,MEASOBJLST=measList(ABISPDIS |
ABISPSUP);
CREATE SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM CREATE SCANF-
BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SCANFBTSM
object. The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the OBJLIST list.
If the SCANFBTSM is in selfAdapting mode it is not possible to add
an object in the objects list.
The maximum number of objects in the objects list has been already
reached.
CREATE SCANFBTSM NAME=SCANFBTSM:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST


1280 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
- Operation Failed
NACK CAUSES:
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANFBTSM:instn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANFBTSM:
NAME = SCANFBTSM:instn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
WRONG_LIST_OF_MEASURE
The measure list cannot be empty.
A measure cannot be duplicated.
Measure not present or only one measure within database.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured for
another SCANFBTSM object or the same measure type is repeated in
the measure list of a SCANFBTSM instance.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The global number of equipped scanner objects must not exceed a fixed
maximum number (90).
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the OBJLIST list.
UNSUCCESSFUL_INVALID_DATE
The start date or the stop date are incorrect.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a
period in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED


A30808-X3247-M230-6-7619

1281
CML:BSC SCANFBTSM
Id:0900d805800d4305
Application Guidelines:
None.
Example of Command Execution:
Create SCANFBTSM:NAME=SCANFBTSM:0,MEASLST=allMeas(0),
OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001,
STOP=31-Dec-2001,RECINT=all(0);
DELETE SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM DELETE SCANF-
BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of
granularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
DELETE SCANFBTSM NAME=SCANFBTSM:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit


1282 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANFBTSM:NAME=SCANFBTSM:0;
GET SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM GET SCANFBTSM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANFBTSM, the relative object instance must be in
LOCKED state.
GET SCANFBTSM NAME=SCANFBTSM:0..89 [,REQATTL= MEASLST
,OBJLST ,GRANP ,START ,STOP ,RECINT ,LSUPDTIME
,LSLOTIME ,LSULOTIME];


A30808-X3247-M230-6-7619

1283
CML:BSC SCANFBTSM
Id:0900d805800d4305
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANFBTSM BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANFBTSM BASICS
None.
NAME: SCANFBTSM
MEASLST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANFBTSM
MEASLST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1284 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
Example of Command Execution:
Get SCANFBTSM:NAME=SCANFBTSM:0,
REQATTL=MEASLST&OBJLST&GRANP& START&STOP&RECINT&
LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANFBTSM BASICS
Get SCANFBTSM BASICS:NAME=SCANFBTSM:0;
GET SCANFBTSM BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM GET SCANFBTSM
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANFBTSM
Application Guidelines:
See GET SCANFBTSM
Example of Command Execution:
See GET SCANFBTSM
GET SCANFBTSM
BASICS
NAME=SCANFBTSM:0..89;


A30808-X3247-M230-6-7619

1285
CML:BSC SCANFBTSM
Id:0900d805800d4305
GET SCANFBTSM STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM GET SCANFBTSM
STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANFBTSM object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None
Example of Command Execution:
Get SCANFBTSM STAT:NAME=SCANFBTSM:0;
GET SCANFBTSM
STAT
NAME=SCANFBTSM:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1286 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
GETCURRENTVALUES SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM GETCURRENTVAL-
UES SCANFBTSM
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
GETCURRENTVAL-
UES SCANFBTSM
NAME=SCANFBTSM:0..89 ,MONOBJ=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID


A30808-X3247-M230-6-7619

1287
CML:BSC SCANFBTSM
Id:0900d805800d4305
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANFBTSM:NAME=SCANFBTSM:0, OBJ=BTSM:0;
LOCK SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM LOCK SCANFBTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANFBTSM NAME=SCANFBTSM:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1288 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANFBTSM:NAME=SCANFBTSM:0;
REMOVE SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM REMOVE SCANF-
BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures from the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
REMOVE SCANFBTSM NAME=SCANFBTSM:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
The measures list cannot be empty.
A measure cannot be duplicated.


A30808-X3247-M230-6-7619

1289
CML:BSC SCANFBTSM
Id:0900d805800d4305
Application Guidelines:
None.
Example of Command Execution:
Remove SCANFBTSM:NAME=SCANFBTSM:0,MEASOBJLST=measList(ABISPDIP |
ABISPSUP);
SET SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM SET SCANFBTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SCANFBTSM
object. The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
Measure not present or only one measure within database.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured
for another SCANFBTSM object or the same measure type is
repeated in the measure list of a SCANFBTSM instance.
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the OBJLIST list.
The specified object is not present in the objects list.
If the SCANFBTSM is in selfAdapting mode it is not possible to
remove an object from the objects list.
There is only one object instance under measure and it is not
possible to remove it.
SET SCANFBTSM NAME=SCANFBTSM:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];


1290 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANFBTSM:instn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANFBTSM:
NAME = SCANFBTSM:instn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
WRONG_LIST_OF_MEASURE
The measure list cannot be empty.
A measure cannot be duplicated.
Measure not present or only one measure within database.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured for
another SCANFBTSM object or the same measure type is repeated in
the measure list of a SCANFBTSM instance.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The global number of equipped scanner objects must not exceed a fixed
maximum number (90).
UNSUCCESSFUL_LIST_OF_OBJECT
The same object instance cannot be repeated in the OBJLIST list.
UNSUCCESSFUL_INVALID_DATE
The start date or the stop date are incorrect.
UNSUCCESSFUL_TIMEFRAME_INCORRECT


A30808-X3247-M230-6-7619

1291
CML:BSC SCANFBTSM
Id:0900d805800d4305
Application Guidelines:
None.
Example of Command Execution:
Set SCANFBTSM:NAME=SCANFBTSM:0,MEASLST=measList(ABISPDIP | ABISP-
SUP),OBJLST=selfAdapting(0), GRANP=MINUTES_60,START=1-Jan-2001,STOP=2-
Jun-2002,RECINT=all(0);
UNLOCK SCANFBTSM
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANFBTSM UNLOCK SCANF-
BTSM
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of
granularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNLOCK SCANFBTSM NAME=SCANFBTSM:0..89;


1292 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4305
SCANFBTSM
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANFBTSM:NAME=SCANFBTSM:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1293
CML:BSC SCANGPRS
Id:0900d805800d4308
SCANGPRS
The SCANGPRS (Scanner GPRS) represents a scanning function on a specific set of
BTS managed objects performing GPRS functions, and is able to report periodically the
collected measurements; the raw data are collected at BSC.
ADD SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS ADD SCANGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANGPRS NAME=SCANGPRS:0..4 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.
UNSUCCESSFUL_LIST_OF_OBJECT


1294 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
Application Guidelines:
None.
Example of Command Execution:
Add SCANGPRS:NAME=SCANGPRS:0,MEASOBJLST=measList(NRETPDU |
NATGPPAG);
CREATE SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS CREATE SCANGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SCANGPRS
object. The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANGPRS NAME=SCANGPRS:0..4 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANGPRS:instn


A30808-X3247-M230-6-7619

1295
CML:BSC SCANGPRS
Id:0900d805800d4308
- Operation Failed
NACK CAUSES:
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANGPRS:
NAME = SCANGPRS:instn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in
an other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a
period in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of
granularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).


1296 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANGPRS:NAME=SCANGPRS:0,MEASLST=allMeas(0),
OBJLST=selfAdapting(0),GRANP=MINUTES_30,START=1-Jan-2001,
STOP=31-Dec-2001,RECINT=all(0);
DELETE SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS DELETE SCANGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a
period in a weekly RECINT.
DELETE SCANGPRS NAME=SCANGPRS:0..4;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA


A30808-X3247-M230-6-7619

1297
CML:BSC SCANGPRS
Id:0900d805800d4308
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANGPRS:NAME=SCANGPRS:0;
GET SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GET SCANGPRS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANGPRS, the relative object instance must be in
LOCKED state.
GET SCANGPRS NAME=SCANGPRS:0..4 [,REQATTL= MEASLST ,OBJLST
,GRANP ,START ,STOP ,RECINT ,LSUPDTIME ,LSLO-
TIME ,LSULOTIME];


1298 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
System Responses:
- Operation Completed
GET SCANGPRS BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANGPRS BASICS
None.
NAME: SCANGPRS
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANGPRS
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1299
CML:BSC SCANGPRS
Id:0900d805800d4308
Example of Command Execution:
Get SCANGPRS:NAME=SCANGPRS:0,REQATTL=MEASLST&OBJLIST&GRANP&
START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANGPRS BASICS
Get SCANGPRS BASICS:NAME=SCANGPRS:0;
GET SCANGPRS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GET SCANGPRS
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANGPRS
Application Guidelines:
See GET SCANGPRS
Example of Command Execution:
See GET SCANGPRS
GET SCANGPRS
BASICS
NAME=SCANGPRS:0..4;


1300 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
GET SCANGPRS STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GET SCANGPRS
STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANGPRS object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANGPRS STAT:NAME=SCANGPRS:0;
GETCURRENTVALUES SCANGPRS
GET SCANGPRS STAT NAME=SCANGPRS:0..4;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVAL-
UES SCANGPRS
NAME=SCANGPRS:0..4 ,MONOBJ=;


A30808-X3247-M230-6-7619

1301
CML:BSC SCANGPRS
Id:0900d805800d4308
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS GETCURRENTVAL-
UES SCANGPRS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)


1302 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
Example of Command Execution:
Getcurrentvalues SCANGPRS:NAME=SCANGPRS:0, OBJ=BTSM:0/BTS:2/ PTP-
PKF:0;
LOCK SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS LOCK SCANGPRS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANGPRS:NAME=SCANGPRS:0;
LOCK SCANGPRS NAME=SCANGPRS:0..4;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1303
CML:BSC SCANGPRS
Id:0900d805800d4308
REMOVE SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS REMOVE SCANGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
REMOVE SCANGPRS NAME=SCANGPRS:0..4 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.


1304 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
Example of Command Execution:
Remove SCANGPRS:NAME=SCANGPRS:0,MEASOBJLST=measList(SUCPDTSE |
NRETPDU | NATGPPAG);
SET SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS SET SCANGPRS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SCANGPRS
object. The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
SET SCANGPRS NAME=SCANGPRS:0..4 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANGPRS:instn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANGPRS:


A30808-X3247-M230-6-7619

1305
CML:BSC SCANGPRS
Id:0900d805800d4308
- Operation Failed
NACK CAUSES:
Application Guidelines:
PM generation report follows the next rules:
NAME = SCANGPRS:instn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in
an other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times .
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of
granularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.


1306 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4308
SCANGPRS
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Set SCANGPRS:NAME=SCANGPRS:0,MEASLST=measList(TNPDTLC | MPDTQLEN
| NPMSDISQ | MEAOLPDC | NATPRRE),OBJLST=selfAdapting(0),
GRANP=MINUTES_60,START=1-Jan-2001,STOP=2-Feb-2002,RECINT=all(0);
UNLOCK SCANGPRS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANGPRS UNLOCK SCANGPRS
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANGPRS:NAME=SCANGPRS:0;
UNLOCK SCANGPRS NAME=SCANGPRS:0..4;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1307
CML:BSC SCANSS7L
Id:0900d805800d430b
SCANSS7L
The SCANSS7L (Scanner SS7 Links) represents a scanning function on a specific set
of SS7 links, and is able to report periodically the collected measurements; the raw data
are collected at BSC.
ADD SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L ADD SCANSS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANSS7L NAME=SCANSS7L:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
WRONG_LIST_OF_MEASURE
Trying to add a measure already present inside scanner measures
list.
UNSUCCESSFUL_LIST_OF_OBJECT


1308 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
Application Guidelines:
None.
Example of Command Execution:
Add SCANSS7L:NAME=SCANSS7L:0,MEASOBJLST=measList(SLFAILAL);
CREATE SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L CREATE SCANSS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SS7 links.
The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
CREATE SCANSS7L NAME=SCANSS7L:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANSS7L:istn


A30808-X3247-M230-6-7619

1309
CML:BSC SCANSS7L
Id:0900d805800d430b
- Operation Failed
NACK CAUSES:
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANSS7L:
name = SCANSS7L:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times .
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD


1310 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
Application Guidelines:
1. The measurements have to be applied to already equipped object instances;
After the creation of the object the ADMINISTRATIVE state is UNLOCKED.
2. When the attribute granularity is set at 0:
the report is provided only after entering an Activate Scan Report command
(ACTIVATE SCAN).
the measurement results are reset after a LOCK/UNLOCK command.
in case of overflow the measurement results are lost and no output is given to
the operator.
3. When a Restart of BSC is done, the Performance Measurements Data collected in
the last granularity are not significant.
Example of Command Execution:
Create SCANSS7L:NAME=SCANSS7L:0,MEASLST=measList(DLKSERST),
OBJLST=selfAdapting(0),GRANP=MINUTES_30, START=1-Jan-2001,STOP=7-Jul-
2002,RECINT=all(0);
DELETE SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L DELETE SCANSS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANSS7L NAME=SCANSS7L:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn


A30808-X3247-M230-6-7619

1311
CML:BSC SCANSS7L
Id:0900d805800d430b
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANSS7L:NAME=SCANSS7L:0;
GET SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GET SCANSS7L
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANSS7L, the relative object instance must be in
LOCKED state.
GET SCANSS7L NAME=SCANSS7L:0..89 [,REQATTL= MEASLST ,OBJLST
,GRANP ,START ,STOP ,RECINT ,LSUPDTIME ,LSLO-
TIME ,LSULOTIME];


1312 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
- Operation Completed
GET SCANSS7L BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
NAME: SCANSS7L
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANSS7L
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1313
CML:BSC SCANSS7L
Id:0900d805800d430b
GET SCANSS7L BASICS
None.
Example of Command Execution:
Get SCANSS7L:NAME=SCANSS7L:0,REQATTL=MEASLST&OBJLIST&
GRANP&REPMETHD& START&STOP&RECINT&LSUPDTIME&LSLOTIME&
LSULOTIME;
GET SCANSS7L BASICS
Get SCANSS7L BASICS:NAME=SCANSS7L:0;
GET SCANSS7L BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GET SCANSS7L
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANSS7L
Application Guidelines:
See GET SCANSS7L
GET SCANSS7L
BASICS
NAME=SCANSS7L:0..89;


1314 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
Example of Command Execution:
See GET SCANSS7L
GET SCANSS7L STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GET SCANSS7L STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SCANSS7L object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANSS7L STAT:NAME=SCANSS7L:0;
GET SCANSS7L STAT NAME=SCANSS7L:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1315
CML:BSC SCANSS7L
Id:0900d805800d430b
GETCURRENTVALUES SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L GETCURRENTVALUES
SCANSS7L
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
GETCURRENTVAL-
UES SCANSS7L
NAME=SCANSS7L:0..89 ,MONOBJ=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID


1316 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
Application Guidelines:
None.
Example of Command Execution:
Getcurrentvalues SCANSS7L:NAME=SCANSS7L:0:OBJ=SS7L:2;
LOCK SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L LOCK SCANSS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)
LOCK SCANSS7L NAME=SCANSS7L:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1317
CML:BSC SCANSS7L
Id:0900d805800d430b
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANSS7L:NAME=SCANSS7L:0;
REMOVE SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L REMOVE SCANSS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
REMOVE SCANSS7L NAME=SCANSS7L:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
WRONG_LIST_OF_MEASURE
Measure not present or only one measure within database.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.


1318 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
Application Guidelines:
None.
Example of Command Execution:
Remove SCANSS7L:NAME=SCANSS7L:0,MEASOBJLST=measList(DSLUNAV |
SLFAILAL);
SET SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L SET SCANSS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the SCANNER of SS7LMEAS class.
The parameters specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.
SET SCANSS7L NAME=SCANSS7L:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANSS7L:
name = SCANSS7L:<istn>


A30808-X3247-M230-6-7619

1319
CML:BSC SCANSS7L
Id:0900d805800d430b
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The measurement activity status has to be in Offduty to submit the SET SCAN
command. Use STOPSCAN SCAN command to set the offduty status.
2. The measurements have to be applied to already equipped object instances.
3. When a Restart of BSC is done, the Performance Measurements Data collected in
the last granularity are not significant.
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.


1320 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430b
SCANSS7L
Example of Command Execution:
Set SCANSS7L:NAME=SCANSS7L:0,MEASLST=allMeas(0),
OBJLST=selfAdapting(0),GRANP=MINUTES_30, START=1-Jan-2001,STOP=22-Nov-
2002,RECINT=all(0);
UNLOCK SCANSS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANSS7L UNLOCK SCANSS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANSS7L:NAME=SCANSS7L:0;
UNLOCK SCANSS7L NAME=SCANSS7L:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1321
CML:BSC SCANTRX
Id:0900d805800d430e
SCANTRX
The SCANTRX (Scanner TRX) represents a scanning function on a specific set of TRX
managed objects, and is able to report periodically the collected measurements; raw
data are collected at BSC.
ADD SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX ADD SCANTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to add measures to the original configuration of a scanner
previously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
ADD SCANTRX NAME=SCANTRX:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure and the same object have been already
configured in an other scanner.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list contains the same object more times.
Scanner is in selfAdapting mode or exceeded max number of objects.
UNSUCCESSFUL_MEMORY_CORRUPTED


1322 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
Application Guidelines:
None.
Example of Command Execution:
Add SCANTRX:NAME=SCANTRX:0,MEASOBJLST=1-1-0;
CREATE SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX CREATE SCANTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the configuration of instance of the scanner of SCANTRX object.
The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
Memory not available.
CREATE SCANTRX NAME=SCANTRX:0..89 ,MEASLST= ,OBJLST=
[,GRANP=] [,START=] [,STOP=] ,RECINT=;
STATUS_MANAGER -> SYSTEM_BROADCAST
*** INFORMATION ***
CHANGED STATE EVENT REPORT:
NAME = SCANTRX:istn
Administrative State = from NO_ADMINISTRATIVE_STATE to UNLOCKED
Operational State = from NO_OPERATIONAL_STATE to ENABLED
Old Availability Status = Null Status
New Availability Status = Off_Duty


A30808-X3247-M230-6-7619

1323
CML:BSC SCANTRX
Id:0900d805800d430e
- Operation Failed
NACK CAUSES:
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Create Ack SCANTRX:
name = SCANTRX:istn
commandResponse = SUCCESSFUL
UNSUCCESSFUL_VAR_OUT_OF_RANGE
Max number of scanner exceeded.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to perform
the command.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
MEASLIST contains other measure besides ILUPLKIC.
MEASLIST contains other measure besides TRANAVTI.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_WRONG_GRANULARITY
With MEASLIST=measlist(ILUPLKIC) the GRANP attribute must be
MINUTES_60.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD


1324 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Create SCANTRX:NAME=SCANTRX:0,MEASLST=TRANAVTI,
OBJLST=selfAdapting(0),GRANP=MINUTES_5,START=1-Jan-2001,STOP=2-Feb-
2002, RECINT=all(0);
DELETE SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX DELETE SCANTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
The command deletes a scanner instance which has been previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.
DELETE SCANTRX NAME=SCANTRX:0..89;
Successful
***INFORMATION***
SCAN CHANGED STATUS: SCAN-instn
Old Scan Activation: Offduty/Active/Inactive
Old Scan Report: Inhibit
New Scan Activation: Undefined
New Scan Report: NA


A30808-X3247-M230-6-7619

1325
CML:BSC SCANTRX
Id:0900d805800d430e
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SCANTRX:NAME=SCANTRX:0;
GET SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GET SCANTRX
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SCANTRX, the relative object instance must be in
LOCKED state.
GET SCANTRX NAME=SCANTRX:0..89 [,REQATTL= MEASLST ,OBJLST
,GRANP ,START ,STOP ,RECINT ,LSUPDTIME ,LSLO-
TIME ,LSULOTIME];


1326 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
System Responses:
- Operation Completed
GET SCANTRX BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SCANTRX BASICS
None.
NAME: SCANTRX
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
NAME: SCANTRX
MEASLIST: measureList
OBJLST: objectList
GRANP: granularityPeriod
START: startDate
STOP: stopDate
RECINT: recordingInterval
LSUPDTIME: lastUpdTime
LSLOTIME: lastLockTime
LSULOTIME: lastUnlockTime
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1327
CML:BSC SCANTRX
Id:0900d805800d430e
Example of Command Execution:
Get SCANTRX:NAME=SCANTRX:0,REQATTL=MEA-
SLST&GRANP&START&STOP&RECINT&LSUPDTIME&LSLOTIME&LSULOTIME;
GET SCANTRX BASICS
Get SCANTRX BASICS:NAME=SCANTRX:0;
GET SCANTRX BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GET SCANTRX BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
The command is used to retrieve the parameters of an existing scanner instance.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
LSUPDTIME lastUpdTime
LSLOTIME lastLockTime
LSULOTIME lastUnlockTime
System Responses:
See GET SCANTRX
Application Guidelines:
See GET SCANTRX
Example of Command Execution:
See GET SCANTRX
GET SCANTRX
BASICS
NAME=SCANTRX:0..89;


1328 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
GET SCANTRX STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GET SCANTRX STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
BTSM object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SCANTRX STAT:NAME=SCANTRX:0;
GETCURRENTVALUES SCANTRX
GET SCANTRX STAT NAME=SCANTRX:0..89;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETCURRENTVAL-
UES SCANTRX
NAME=SCANTRX:0..89 ,MONOBJ=;


A30808-X3247-M230-6-7619

1329
CML:BSC SCANTRX
Id:0900d805800d430e
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX GETCURRENTVALUES
SCANTRX
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command provides a report of the partial results, collected after the last report, on
a scanner created previously.
Long Names:
NAME Addres of the managed object
MONOBJ monitoredObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
REJECTED_OTHER_COMMAND_IN_PROGRESS
GetCurrentValues request for two or more scan
reports is in progress (one scanner already active).
UNSUCCESSFUL_INVALID_STATUS
Scanner not configured or it is in the OFF_DUTY
status.
UNSUCCESSFUL_INVALID_OBJECT
Object not equipped.
Object does not belong to the scanner object list.
Object has been created before 5 minutes expiring. A
report is generated only if object has been created
within 5 minutes period.
UNSUCCESSFUL_WRONG_MEID
Wrong mnemonic type. GetCurrentValues must be
requested on an object with same type of measure-
ment object (e.g. GetCurrentValues SCAN-
BTS,OBJ=BTSM:2/BTS:3)


1330 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
Example of Command Execution:
Getcurrentvalues SCANTRX:NAME=SCANTRX:0,OBJ=BTSM:0/BTS:2/TRX:3;
LOCK SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX LOCK SCANTRX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SCANTRX:NAME=SCANTRX:0;
LOCK SCANTRX NAME=SCANTRX:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1331
CML:BSC SCANTRX
Id:0900d805800d430e
REMOVE SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX REMOVE SCANTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to remove measures to the original configuration of a scanner pre-
viously created by the user.
Long Names:
NAME Addres of the managed object
MEASOBJLST measObjList
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Remove SCANTRX:NAME=SCANTRX:0,MEASOBJLST=0-1-4;
REMOVE SCANTRX NAME=SCANTRX:0..89 ,MEASOBJLST=;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in
LOCKED state.
UNSUCCESSFUL_LIST_OF_OBJECT
The object list must contain at least one object under measure.
Object under measure must be present within database or scanner in
selfadapting mode.
UNSUCCESSFUL_MEMORY_CORRUPTED
Memory not available.


1332 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
SET SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX SET SCANTRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the configuration of instance of the scanner of SCANTRX object.
The parameter specify the values for the scheduling and reporting activities.
Long Names:
NAME Addres of the managed object
MEASLST measureList
OBJLST objectList
GRANP granularityPeriod
START startDate
STOP stopDate
RECINT recordingInterval
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
SET SCANTRX NAME=SCANTRX:0..89 [,MEASLST=] [,OBJLST=]
[,GRANP=] [,START=] [,STOP=] [,RECINT=];
DBA -> LMT_LOCAL
*** RESPONSE TO JOB 1 ***
Set Ack SCANTRX:
name = SCANTRX:<istn>
commandResponse = SUCCESSFUL
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the object instance is in LOCKED
state.
UNSUCCESSFUL_MEAS_ALREADY_PRESENT


A30808-X3247-M230-6-7619

1333
CML:BSC SCANTRX
Id:0900d805800d430e
Application Guidelines:
PM generation report follows the next rules:
Reports contain only equipped objects counters. If all objects under measure are not
equipped, a report with objects number equal to zero is always generated;
Availability status is ON_DUTY if and only if scanner is unlocked and current time is
within schedulation period.
Example of Command Execution:
Set SCANTRX:NAME=SCANTRX:0,MEASLST=ILUPLKIC,OBJLST=selfAdapting(0),
GRANP=MINUTES_5,START=3-Mar-2001,STOP=4-Dec-2002,RECINT=all(0);
The same measure on the same object has been already configured in an
other scanner.
WRONG_LIST_OF_MEASURE
Empty MEASLST is not allowed.
MEASLIST contains other measure besides ILUPLKIC.
MEASLIST contains other measure besides TRANAVTI.
UNSUCCESSFUL_LIST_OF_OBJECT
The OBJLIST contains the same object more times.
UNSUCCESSFUL_WRONG_GRANULARITY
With MEASLIST=measlist(ILUPLKIC) the GRANP attribute must be
MINUTES_60.
UNSUCCESSFUL_TIMEFRAME_INCORRECT
The scheduling stop date has to be equal or greater than start date.
At least one day within START and STOP dates should be given a period
in a weekly RECINT.
UNSUCCESSFUL_TIMEFRAME_ELAPSED
The scheduling stop date has to be equal or greater than current date.
UNSUCCESSFUL_WRONG_RECORDING_DURATION
Recording period is not multiple of granularity or RECINT=weekly() and
every daily schedulation is none.
UNSUCCESSFUL_WRONG_RECORDING_START
The period_start_min of every periodDuration must be a multiple of gran-
ularity.
UNSUCCESSFUL_WRONG_RECORDING_PERIOD
Invalid period in RECINT: (start time must be before stop time).
UNSUCCESSFUL_RECORDING_OVERLAPPED
Periods must not overlap.


1334 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d430e
SCANTRX
UNLOCK SCANTRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SCANTRX UNLOCK SCANTRX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SCANTRX:NAME=SCANTRX:0;
UNLOCK SCANTRX NAME=SCANTRX:0..89;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1335
CML:BSC SOFTWARE-MANAGEMENT
Id:0900d805800d4311
SOFTWARE-MANAGEMENT
The SOFTWARE-MANAGEMENT object provides the functionality to execute BSS
software management and to administrate the BSC file system.
DNLFILE SOFTWARE-MANAGEMENT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT DNLFILE SOFTWARE-
MANAGEMENT
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows the user to transfer a Data file from the LMT disk to a directory in
the BSC disk. If the directory specified in the command does not exist, it is automatically
created.
Long Names:
IDSOFTWARE-MANAGEMENT Addres of the managed object
SRCPATH relatedFiles
DESTDIR DestinationDir
OVERWRITE Overwrite
System Responses:
- Operation Completed
The LMT notifies the percentage of downloaded files in steps of 5% (on the "info line")
and the successful completion of the procedure.
- Operation Failed
DNLFILE SOFTWARE-
MANAGEMENT
SRCPATH= ,DESTDIR= ,OVERWRITE=;
Possible errors, causing the procedure to abort, notified by the LMT are:
File Not Found
Message Out Of Sequence
Aborted By User
Time Out Expired
Aborted By Network Element
File Too Long For Zero Window Size
Disk Access Error
User Abort Refused


1336 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4311
SOFTWARE-MANAGEMENT
Application Guidelines:
If the download of a DATA file is required, the source pathname has to be specified.
The download of a file should not be performed while another file system operation,
involving that file, is in progress, even when required by the RC. Such operation could
be: move, copy, delete, network element download, Upload.
Example of Command Execution:
DNLFILE:SRCPATH="D:\Siemens\Fw\MPCC.FWI", DESTDIR="FIRMWARE",
OVERWRITE="YES";
LOADMPCC SOFTWARE-MANAGEMENT
Internal SW Error
Segment Out Of Sequence
Last Segment Expected
Disk Write Error
Disk Error
Crosscopy In Progress (DK40)
Invalid SVR
File Already Exists
Wrong Destination Path
Possible errors, causing the procedure to abort, notified by the download task on
MPCC and displayed by the LMT are:
STRING_TOO_LONG
A non-terminated string is present in a message field.
INVALID_PARAMETER_NCK
A message parameter is syntactically incorrect or two message parameters
are conflicting.
RTE Failure
The download task could not obtain an Operating System service.
File System Failed
The download task could not obtain a File System service.
File Present
The user requested an unforced download of a file already stored in the
destination directory.
LOADMPCC
SOFTWARE-MANAGE-
MENT
SRCPATH= ,SOURCE=;


A30808-X3247-M230-6-7619

1337
CML:BSC SOFTWARE-MANAGEMENT
Id:0900d805800d4311
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT LOADMPCC SOFTWARE-
MANAGEMENT
Applicability:
Phase 1.
Visibility level: 3.
Command Description:
This command is the only one available when the LMT BSC is in Phase 1, that is when
the MPCC is running in Firmware.
This command loads the software from LMT disk into the MPCC internal memory. When
the command is completed, the MPCC is running in software.
Long Names:
IDSOFTWARE-MANAGEMENT Addres of the managed object
SRCPATH relatedFiles
SOURCE source
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
LOADMPCC:SRCPATH="C:\Load\hb0114zz.swl",SOURCE=LMT;
UPLBTSLOG SOFTWARE-MANAGEMENT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLBTSLOG SOFTWARE-
MANAGEMENT
NOT MPCC FILE
ABS CRC ERROR
TIMEOUT ERROR
MSG SEQUENCE ERROR
UPLBTSLOG
SOFTWARE-MANAGE-
MENT
INSTANCE= ,DESTDIR= ,FILE= ,FILETYPE= ,OVER-
WRITE=;


1338 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4311
SOFTWARE-MANAGEMENT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to upload a BTSE log file.
Long Names:
IDSOFTWARE-MANAGEMENT Addres of the managed object
INSTANCE instance
DESTDIR DestinationDir
FILE file
FILETYPE fileType
OVERWRITE Overwrite
System Responses:
- Operation Completed
The LMT notifies the successful completion of the procedure.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only an upload at the time on a specific network element is allowed.
Message Out Of Sequence
Aborted By Network Element
Aborted By User
Disk Error
File Already Exists
Could not Open Destination File
Wrong Packet Number
Last segment expected
Resource Not Available
Invalid File Type
File Not Available At Destination
File In Use
Updating of Flash In Progress
Message Cannot be Performed
File System Error
Object not equipped.


A30808-X3247-M230-6-7619

1339
CML:BSC SOFTWARE-MANAGEMENT
Id:0900d805800d4311
Example of Command Execution:
UPLBTSLOG:INSTANCE="23",DESTDIR="D:\Siemens\Btslogdir",
FILE="Bts-23.log",FILETYPE="ALARM_BUFFER",OVERWRITE="YES";
UPLBTSTDLOG SOFTWARE-MANAGEMENT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLBTSTDLOG
SOFTWARE-MANAGEMENT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to upload a BTSTD log file.
Long Names:
IDSOFTWARE-MANAGEMENT Addres of the managed object
INSTANCE instance
DESTDIR DestinationDir
FILE file
FILETYPE fileType
OVERWRITE Overwrite
System Responses:
- Operation Completed
The LMT notifies the successful completion of the procedure.
- Operation Failed
NACK CAUSES:
UPLBTSTDLOG
SOFTWARE-MANAGE-
MENT
INSTANCE= ,DESTDIR= ,FILE= ,FILETYPE= ,OVER-
WRITE=;
Message Out Of Sequence
Aborted By Network Element
Aborted By User
Disk Error
File Already Exists
Could not Open Destination File
Wrong Packet Number
Last segment expected


1340 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4311
SOFTWARE-MANAGEMENT
Application Guidelines:
Only an upload at the time on a specific network element is allowed.
Example of Command Execution:
UPLBTSTDLOG:INSTANCE="23",DESTDIR="D:\Siemens\Btslogdir",
FILE="Bts-23.log",FILETYPE="ALARM_BUFFER",OVERWRITE="YES";
UPLFILE SOFTWARE-MANAGEMENT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLFILE SOFTWARE-
MANAGEMENT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to transfer a file from a directory of the BSC disk to the LMT disk.
The file must be a Data file (e.g. database, measures, BSC log file...).
This command is also used to transfer the BSC log file stored in the BSC disk directory
LOG.
Long Names:
IDSOFTWARE-MANAGEMENT Addres of the managed object
DESTDIR DestinationDir
FILE file
SRCDIR sourceDir
OVERWRITE Overwrite
Resource Not Available
Invalid File Type
File Not Available At Destination
File In Use
Updating of Flash In Progress
Message Cannot be Performed
File System Error
Object not equipped
UPLFILE SOFTWARE-
MANAGEMENT
DESTDIR= ,FILE= ,SRCDIR= ,OVERWRITE=;


A30808-X3247-M230-6-7619

1341
CML:BSC SOFTWARE-MANAGEMENT
Id:0900d805800d4311
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
The upload of a file should not be performed while another file system operation, involv-
ing that file, is in progress, even when required by the RC. Such operation could be:
move, copy, delete, download.
Example of Command Execution:
UPLFILE:DESTDIR="D:\Siemens\UploadDir\", FILE="MPCC.FWI",
SRCDIR="FIRMWARE", OVERWRITE="YES";
UPLTRAULOG SOFTWARE-MANAGEMENT
The LMT notifies the successful completion of the procedure.
force NOT_FORCED
source file DBFILE.DBA
dir. name SYS_BACKUP
dest. file DBFILE_UPL.DBA
File Not Found
Message Out Of Sequence
Aborted By User
Time Out Expired
Aborted By Network Element
Internal SW Error
Segment Out Of Sequence
Last Segment Expected
Disk Access Error
Disk Write Error
Disk Error
File Already Exists
UPLTRAULOG
SOFTWARE-MANAGE-
MENT
INSTANCE= ,DESTDIR= ,FILE= ,FILETYPE= ,OVER-
WRITE=;


1342 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4311
SOFTWARE-MANAGEMENT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT UPLTRAULOG
SOFTWARE-MANAGEMENT
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to upload a TRAU log file.
Long Names:
IDSOFTWARE-MANAGEMENT Addres of the managed object
INSTANCE instance
DESTDIR DestinationDir
FILE file
FILETYPE fileType
OVERWRITE Overwrite
System Responses:
- Operation Completed
The LMT notifies the successful completion of the procedure.
- Operation Failed
NACK CAUSES:
Message Out Of Sequence
Aborted By Network Element
Aborted By User
Disk Error
File Already Exists
Could not Open Destination File
Wrong Packet Number
Last segment expected
Resource Not Available
Invalid File Type
File Not Available At Destination
File In Use
Updating of Flash In Progress
Message Cannot be Performed
File System Error
Object not equipped


A30808-X3247-M230-6-7619

1343
CML:BSC SOFTWARE-MANAGEMENT
Id:0900d805800d4311
Application Guidelines:
Only an upload at the time on a specific network element is allowed.
Example of Command Execution:
UPLTRAULOG:INSTANCE="23",DESTDIR="D:\Siemens\Traulogdir",
FILE="Bts-23.log",FILETYPE="ALARM_BUFFER",OVERWRITE="YES";


1344 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
SS7L
The SS7L object represents an SS7 link.
CREATE SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L CREATE SS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a SS7 signalling link to the system.
Long Names:
NAME Addres of the managed object
TSLA tsla
SLC signallingLinkCode
LKSET linkSet
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE SS7L NAME=SS7L:0..16 ,TSLA= ,SLC= ,LKSET=;
SUPERORDINATE_NOTEQUIPPED
The OPC object instance must be already equipped.
The relevant PCM line used for the link must be already
equipped.
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The timeslot "timeslotn" of all the pcma lines (or of the
pcms line) connected to the TRAU has not to be already
reserved in order to submit the CREATE SS7L command.
The selected TSLA is already carrying a NUC.
UNSUCCESSFUL_INVALID_ATTRIBUTES


A30808-X3247-M230-6-7619

1345
CML:BSC SS7L
Id:0900d805800d4315
Application Guidelines:
After the creation of the object, the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
Example of Command Execution:
Create SS7L:NAME=SS7L:0,TSLA=0-2,SLC=10,LKSET=0;
DELETE SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L DELETE SS7L
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a SS7 signalling link previously created through the CREATE
SS7L command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
The value assigned to the SLC attribute is already used by
another SS7L equipped in the BSC.
UNSUCCESSFUL_INVALID_TIME_SLOT
The value assigned to the tslan field of the TSLA attribute
is not compatible with the PCM line type attribute
(parameter PCMTYPE of BSC object).
UNSUCCESSFUL_INVALID_STATUS
The command can be performed only if the TRAU object
instance is in LOCKED state.
UNSUCCESSFUL_LINKSET_ONE_CONNECTED
The first instance of the SS7L object must be created on
linkset 0.
No instances of SS7L object can be created on linkset 1 if
the SMLCSPC of OPC object is not configured.
DELETE SS7L NAME=SS7L:0..16;


1346 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SS7L:NAME=SS7L:0;
GET SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GET SS7L
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve information about a SS7 signalling link previously
created through the CREATE SS7L command.
Long Names:
NAME Addres of the managed object
TSLA tsla
SLC signallingLinkCode
TOPOREL topologicalRelationship
LKSET linkSet
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SS7L, the relative object instance must be in
LOCKED state.
Before deleting a SS7L, the related TRAU object instance must
be in LOCKED state.
UNSUCCESSFUL_LINKSET_ONE_CONNECTED
The SS7L object cannot be deleted with linkset 0 if a SS7L with
linkset 1 exists.
GET SS7L NAME=SS7L:0..16 [,REQATTL= TSLA ,SLC ,TOPOREL
,LKSET];


A30808-X3247-M230-6-7619

1347
CML:BSC SS7L
Id:0900d805800d4315
System Responses:
- Operation Completed
GET SS7L BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SS7L BASICS
None.
Example of Command Execution:
Get SS7L:NAME=SS7L:0,REQATTL=TSLA&SLC&TOPOREL&LKSET;
GET SS7L BASICS
Get SS7L BASICS:NAME=SS7L:0;
GET SS7L BASICS
NAME: name
TSLA: tsla
PCMAN: pcmaNumber
TSLAN: tslaNumber
SLC: SignallingLinkCode
LKSET: linkset
NAME: name
TSLA: tsla
PCMAN: pcmaNumber
TSLAN: tslaNumber
SLC: SignallingLinkCode
LKSET: linkset
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET SS7L BASICS NAME=SS7L:0..16;


1348 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GET SS7L BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve information about a SS7 signalling link previously
created through the CREATE SS7L command.
Long Names:
NAME Addres of the managed object
TSLA tsla
SLC signallingLinkCode
TOPOREL topologicalRelationship
LKSET linkSet
System Responses:
See GET SS7L
Application Guidelines:
See GET SS7L
Example of Command Execution:
See GET SS7L
GET SS7L STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GET SS7L STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SS7L object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
GET SS7L STAT NAME=SS7L:0..16;


A30808-X3247-M230-6-7619

1349
CML:BSC SS7L
Id:0900d805800d4315
Unknown Status (UNK)
S7 Status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. Only sets with raised bits are shown.
2. If, after an MPCC switch, the SS7 link stays in restoring state, a GET SS7L STAT
command has to be performed. If in the result of the previous command adjacent SP
status is equal to MTP_ACCESSIBLE, it is necessary to make lock and unlock of the
SS7L in order to synchronize the state.
Example of Command Execution:
Get SS7L STAT:NAME=SS7L:1;
GETRELATIONSHIP SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GETRELATIONSHIP SS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the SS7L object the related HMOs are the following: PWRD, MPCC, TDPC, MEMT,
NTW and PPXL.
Long Names:
NAME Addres of the managed object
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETRELATIONSHIP
SS7L
NAME=SS7L:0..16;


1350 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship SS7L:NAME=SS7L:0;
GETSUBO SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L GETSUBO SS7L
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more packs with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO SS7L NAME=SS7L:0..16;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

1351
CML:BSC SS7L
Id:0900d805800d4315
Application Guidelines:
None.
Example of Command Execution:
Getsubo SS7L:NAME=SS7L:0;
INHIBIT SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L INHIBIT SS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows the inhibition of a SS7 link.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The object instance must be already equipped.
INHIBIT SS7L NAME=SS7L:0..16;
INHIBIT ALLOWED: <object_id>
It means that the system has properly checked and inhibited
the link specified in the <object_id> field.
INHIBIT DENIED: <object_id>, <cause>
It indicates that the inhibition of the link is not possible.
The meaning of the information fields within the arrow
brackets is as follows:
<object_id> It indicates the link where the inhibition procedure is executed
and has the following format:
SS7L-ss7ln where ss7ln can assume the values 0 to 15.
cause It indicates where the inhibition has been rejected and can
assume the following values:
LOCAL:
It means that the link cannot be inhibited locally.
REMOTE:
It means that the link cannot be inhibited at the remote end.


1352 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Inhibit SS7L:NAME=SS7L:0;
LOCK SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L LOCK SS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
LOCK SS7L NAME=SS7L:0..16;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
STANDBY_PLLH_DAC_WORD_EVOLVING
It is emitted when the PLLH has become synchronized to an
external source little time ago, and the switch of the master
PLLH (for LOCK or SWITCH command) would leave the fre-
quency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone
PROVIDING SERVICE. The same can happen if less than 5
minutes have passed since last switch of NTW.


A30808-X3247-M230-6-7619

1353
CML:BSC SS7L
Id:0900d805800d4315
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped.
To avoid loss of calls by locking objects TRX or CHAN a request for usage state of
this objects should be done previously (e.g. GET state status). In case returned
usage state is "active" or "busy" locking should not be done (otherwise calls are
dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SS7L:NAME=SS7L:0;
TESTLINK SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L TESTLINK SS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to diagnose a SS7 link to verify the correct message exchange
between signalling points.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
TESTLINK SS7L NAME=SS7L:0..16;
TEST LINK PASSED: <object_id>, <cause>
It indicates that the test was unsuccessful.
The meaning of the information fields within the arrow
brackets is the following:
object_id It indicates the link where the test procedure is executed and
has the following format:
SS7L-ss7ln where ss7ln can assume values from 0 to 15.
cause It indicates the reason why the test failed and can assume the
following values:


1354 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Testlink SS7L:NAME=SS7L:0;
UNINHIBIT SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L UNINHIBIT SS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows the uninhibited of a SS7 link.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
WRONG PATTERN:
It means that the acknowledgment MSU sent from the remote
end has the wrong test pattern.
TIMER EXPIRED:
It means that the acknowledgment MSU did not arrive in the
specified time.
UNINHIBIT SS7L NAME=SS7L:0..16;
UNINHIBIT ALLOWED:
<object_id> It means that the system has properly checked and uninhib-
ited the link specified in the <object_id> field.
UNINHIBIT DENIED:
<object_id>, <cause> It indicates that the link must remain inhibited.
The meaning of the information fields within the arrow
brackets is as follows:
<object_id> It indicates the link where the uninhibited procedure is
executed and has the following format:


A30808-X3247-M230-6-7619

1355
CML:BSC SS7L
Id:0900d805800d4315
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Uninhibit SS7L:NAME=SS7L:0;
UNLOCK SS7L
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7L UNLOCK SS7L
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
SS7L-ss7ln where ss7ln can assume the values from 0 to 15.
cause indicates whether the refusal of the request is local or remote
and can assume the following values:
LOCAL:
It means that the link cannot be uninhibited for local causes.
REMOTE:
It means that the link cannot be uninhibited for remote causes.
UNLOCK SS7L NAME=SS7L:0..16;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


1356 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4315
SS7L
Application Guidelines:
None.
Example of Command Execution:
Unlock SS7L:NAME=SS7L:0;
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1357
CML:BSC SS7S
Id:0900d805800d4318
SS7S
The SS7S object summarizes the operational state of all the SS7L objects. It is enabled
if all the SS7L objects are enabled.
GET SS7S STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7S GET SS7S STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SS7S object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK)
S7 Status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get SS7S STAT:NAME=SS7S:0;
GET SS7S STAT NAME=SS7S:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1358 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4318
SS7S
GETSUBO SS7S
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SS7S GETSUBO SS7S
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more packs with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed
notifying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo SS7S:NAME=SS7S:0;
GETSUBO SS7S NAME=SS7S:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1359
CML:BSC SUBTSLB
Id:0900d805800d431b
SUBTSLB
The SUBTSLB object provides the functionality of the 16 kbit/s subslots on the Abis
interface. Each 16 kbit/s subslot (SUBTSLB instance) is associated to a LAPD channel
(LPDLM instance). The set of 16 kbit/s subslots (SUBTSLB instances) reserved to a
BTSM for traffic services is called Abis pool. In case of BTS supporting dynamic Abis
allocation, Abis subslots are selected from the pool and allocated to radio channels at
channel activation. In case of BTS supporting static Abis allocation, Abis subslots are
selected from the pool and allocated to radio channels by O&M procedures.
An Abis pool is available to all BTSM radio channels and is composed of one or more
Abis subpools. An Abis subpool is a set of 16 kbit/s Abis subslots, belonging to a single
PCM line, routed together with the associated LPDLM instance on the same PCM line
(see below).
CREATE SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB CREATE
SUBTSLB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates an instance of the SUBTSLB object. By means of the ASSLAPD
attribute, the SUBTSLB object instance is associated to a LPDLM object instance.
Long Names:
NAME Addres of the managed object
ASSLAPD associatedLapd
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE SUBTSLB NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3 ,ASS-
LAPD=;
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The PCMB object instance must be already equipped.


1360 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431b
SUBTSLB
Application Guidelines:
None.
Example of Command Execution:
Create SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0,
ASSLAPD=BTSM:0/LPDLM:0;
DELETE SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB DELETE
SUBTSLB
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a SUBTSLB object instance previously created through the
CREATE SUBTSLB command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
UNSUCCESSFUL_INVALID_ATTRIBUTES
The associated Lapd must be an equipped LPDLM.
The SUBTSLB object and the associated Lapd must
belong to the same PCMB.
UNSUCCESSFUL_INVALID_TIME_SLOT
The value assigned to the timeslot number must be com-
patible with the PCM line type (PCM24 or PCM30).
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The selected PCMB timeslot must not be already
equipped because of the presence of an L1CTS, LPDLM
or NUC.
UNSUCCESSFUL_SUB_SLOT_ALREADY_ALLOCATED
If two PCMBs connected to the same port exist, it is not
possible to create two SUBTSLBs having the same
address on those PCMBs.
DELETE SUBTSLB NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;


A30808-X3247-M230-6-7619

1361
CML:BSC SUBTSLB
Id:0900d805800d431b
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0;
GET SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GET
SUBTSLB
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve information about a SUBTSLB previously created
through the CREATE SUBTSLB command.
Long Names:
NAME Addres of the managed object
ASSLAPD associatedLapd
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SUBTSLB, the relative object instance must
be in LOCKED state.
UNSUCCESSFUL_LINK_CONNECTED
If the SW Version running on the superordinate BTSM belongs
to BR6.0 release (see EXPSWV parameter description), that is
Abis allocation is 'static', the command is accepted only if no
CHAN is statically associated to that SUBTSLB.
GET SUBTSLB NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3
[,REQATTL= ASSLAPD];


1362 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431b
SUBTSLB
System Responses:
- Operation Completed
GET SUBTSLB BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SUBTSLB BASICS
None.
Example of Command Execution:
Get SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0,REQATTL=ASSLAPD;
GET SUBTSLB BASICS
Get SUBTSLB BASICS:NAME=PCMB:0/TSLB:1/SUBTSLB:0;
GET SUBTSLB BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GET
SUBTSLB BASICS
Applicability:
Phase 2.
Visibility level: 0.
NAME: name
ASSLAPD: associatedLapd
NAME: name
ASSLAPD: associatedLapd
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET SUBTSLB BASICS NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;


A30808-X3247-M230-6-7619

1363
CML:BSC SUBTSLB
Id:0900d805800d431b
Command Description:
This command is used to retrieve information about a SUBTSLB previously created
through the CREATE SUBTSLB command.
Long Names:
NAME Addres of the managed object
ASSLAPD associatedLapd
System Responses:
See GET SUBTSLB
Application Guidelines:
See GET SUBTSLB
Example of Command Execution:
See GET SUBTSLB
GET SUBTSLB STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GET
SUBTSLB STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SUBTSLB object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Availability Status (AVS).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
GET SUBTSLB STAT NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;


1364 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431b
SUBTSLB
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SUBTSLB STAT:NAME=PCMB:0/TSLB:1/SUBTSLB:0;
GETRELATIONSHIP SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB GETRE-
LATIONSHIP SUBTSLB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of all the HMOs
(Hardware Managed Object) supporting the FMO functionality.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETRELATIONSHIP
SUBTSLB
NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

1365
CML:BSC SUBTSLB
Id:0900d805800d431b
Application Guidelines:
None
Example of Command Execution:
Getrelationship SUBTSLBL:NAME=PCMB:0/TSLB:1/SUBTSLB:0;
LOCK SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB LOCK
SUBTSLB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state LOCKED.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Lock SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0;
SHUTDOWN SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB
SHUTDOWN SUBTSLB
Applicability:
Phase 2.
LOCK SUBTSLB NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;
SHUTDOWN SUBTSLB NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;


1366 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431b
SUBTSLB
Visibility level: 2.
Command Description:
This command allows the graceful transition of a SUBTSLB object instance from the
administrative state UNLOCKED to the administrative state LOCKED after the object
has terminated its current activity.
After a SHUTDOWN SUBTSLB command, the system tries for 5 minutes the handover
of circuit switched services. If the handover is unsuccessful, the call is dropped. The
behaviour for packet switched services is the same as in LOCK case.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Shutdown SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0;
UNLOCK SUBTSLB
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMB TSLB SUBTSLB UNLOCK
SUBTSLB
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object at the administrative state UNLOCKED.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNLOCK SUBTSLB NAME=PCMB:0..117/TSLB:1..31/SUBTSLB:0..3;


A30808-X3247-M230-6-7619

1367
CML:BSC SUBTSLB
Id:0900d805800d431b
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SUBTSLB:NAME=PCMB:0/TSLB:1/SUBTSLB:0;


1368 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431e
SYNC
SYNC
The SYNC object is the synchronization source which arrives to the BSC Network Clock
from the MSC, via A interface - TRAU - Asub interface.
CREATE SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC CREATE SYNC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a clock synchronization signal (SYNC) to the system.
The synchronization signal is derived from the 2048 kbit/s signal of the given PCMS line
(PCM line on the "Asub" interface).
This field identifies the priority too; the value zero is associated with the highest priority.
Long Names:
NAME Addres of the managed object
PCMSOBJ relatedPcmsObject
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. This synchronization source has lower priority than SYNE synchronization source.
2. After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. The UNLOCK command is required to put this object in service.
3. In case of failure at PCM-Line, selected by TRAU as synchronization line, TRAU
selects a different line not before one second has expired. Therefore, if BSC detects
CREATE SYNC NAME=SYNC:0..47 ,PCMSOBJ=;
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
SUPERORDINATE_NOTEQUIPPED
The relevant TRAU attached to the PCMS line must be
already equipped.


A30808-X3247-M230-6-7619

1369
CML:BSC SYNC
Id:0900d805800d431e
synchronization problems prior to TRAU, BSC selects a different TRAU (if available)
for synchronisation purpose.
Example of Command Execution:
Create SYNC:NAME=SYNC:0,PCMSOBJ=0;
DELETE SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC DELETE SYNC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a Synchronization Source (SYNC) previously created through
the CREATE SYNC command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete SYNC:NAME=SYNC:0;
GET SYNC
DELETE SYNC NAME=SYNC:0..47;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SYNC, the relative object instance must
be in LOCKED state.
GET SYNC NAME=SYNC:0..47 [,REQATTL= PCMSOBJ];


1370 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431e
SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GET SYNC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters relevant to the clock synchronization
signal.
Long Names:
NAME Addres of the managed object
PCMSOBJ relatedPcmsObject
System Responses:
- Operation Completed
GET SYNC BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET SYNC BASICS
None.
Example of Command Execution:
Get SYNC:NAME=SYNC:0,REQATTL=PCMSOBJ;
GET SYNC BASICS
Get SYNC BASICS:NAME=SYNC:0;
NAME: name
PCMSOBJ: relatedPcmsObject
NAME: name
PCMSOBJ: relatedPcmsObject
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1371
CML:BSC SYNC
Id:0900d805800d431e
GET SYNC BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GET SYNC BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters relevant to the clock synchronization
signal.
Long Names:
NAME Addres of the managed object
PCMSOBJ relatedPcmsObject
System Responses:
See GET SYNC
Application Guidelines:
See GET SYNC
Example of Command Execution:
See GET SYNC
GET SYNC STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GET SYNC STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SYNC object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
GET SYNC BASICS NAME=SYNC:0..47;
GET SYNC STAT NAME=SYNC:0..47;


1372 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431e
SYNC
Control Status (CTS)
Standby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get SYNC STAT:NAME=SYNC:0;
GETRELATIONSHIP SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GETRELATIONSHIP SYNC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the SYNC object the related HMOs are the following: LICD/LICDS, EPWR, PWRD,
MPCC, TDPC, MEMT, NTW, BSMS and TPWR.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETRELATIONSHIP
SYNC
NAME=SYNC:0..47;


A30808-X3247-M230-6-7619

1373
CML:BSC SYNC
Id:0900d805800d431e
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship SYNC:NAME=SYNC:0;
GETSUBO SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC GETSUBO SYNC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of the direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more packs with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed
notifying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object instance does not provide any relationship attribute.
GETSUBO SYNC NAME=SYNC:0..47;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1374 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431e
SYNC
Application Guidelines:
None.
Example of Command Execution:
Getsubo SYNC:NAME=SYNC:0;
LOCK SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC LOCK SYNC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
LOCK SYNC NAME=SYNC:0..47;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
STANDBY_PLLH_DAC_WORD_EVOLVING
It is emitted when the PLLH has become synchronized to an
external source little time ago, and the switch of the master
PLLH (for LOCK or SWITCH command) would leave the fre-
quency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone
PROVIDING SERVICE. The same can happen if less than 5
minutes have passed since last switch of NTW.


A30808-X3247-M230-6-7619

1375
CML:BSC SYNC
Id:0900d805800d431e
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SYNC:NAME=SYNC:0;
UNLOCK SYNC
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNC UNLOCK SYNC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNLOCK SYNC NAME=SYNC:0..47;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1376 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d431e
SYNC
Example of Command Execution:
Unlock SYNC:NAME=SYNC:0;


A30808-X3247-M230-6-7619

1377
CML:BSC SYNCO
Id:0900d805800d4321
SYNCO
The SYNCO object is the synchronization complex control; it consists of synchronization
source equipment and functions.
GETINFO SYNCO
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNCO GETINFO SYNCO
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The states and the standby status for both NTW copies
2. The version of the PLLH card.
3. The synchronization operation mode.
4. The current frequency.
5. The time elapsed since the synchronization operation mode became
SYNCHRONIZED.
6. The TUNE WORD value (frequency stored in the EEPROM) and the DAC word
value (frequency present output by the PLLH).
7. The DELTA attribute: a signed value which represents the error ratio between the
two frequencies controlled by the two previous attributes TUNE and DAC and
dependent from the PLLH version:
PLLHV1: DELTA=DAC-TUNE
PLLHV2:DELTA=(DAC-TUNE)/5"
8. The phase error.
9. The states and statuses of each equipped SYNE: AST, OST, AVS, CST,
STNDBYST, PRS.
10. For each equipped SYNC:
The states and statuses: AST, OST, AVS, CST, STNDBYST, PRS.
The TRAU number.
The synchronization source (MSC or BSC).
The number of PCMA line taking the synchronization signal (if SYNC source is
MSC, else no SYNC source from MSC will be displayed).
The line interface card (LICD) number and circuit.
The working mode (SINGLE_TRUNK, DOUBLE_TRUNK).
GETINFO SYNCO NAME=SYNCO:0..0;


1378 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4321
SYNCO
The used trunk (TRUNK_A, TRUNK_B).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO SYNCO ACK:
BSC_CONTROLLER -> LMT_LOCAL
PC Time&DATE = 05:10:39 25/04/1999
*** RESPONSE TO JOB 1***
Get Info Report Ack SYNCO:
name = SYNCO:0
BSC_CONTROLLER -> LMT_LOCAL
PC Time&DATE = 05:10:39 25/04/1999
NE Time&Date = 14:19:54 26/04/1999
*** INFORMATION ***
GET INFO REPORT SYNCO:
NAME = SYNCO:0
NTW 0:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
STANDBY STATUS: PROVIDING_SERVICE
NTW 1:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
STANDBY STATUS: HOT_STANDBY
PLLH NR. PLLH VER. SYNC_MODE FREQ
0 12345678901234567890 ASYNC_ON_TUNE 1
1 523676 SLAVE 3
PLLH NR. ELAPSED_TIME TUNE DAC DELTA PHASE ERROR
0 31-09:55:20 432 4367 53 9
1 06-21:11:03 1 7 9645 1
SYNE 0:
ADMINISTRATIVE STATE: UNLOCKED


A30808-X3247-M230-6-7619

1379
CML:BSC SYNCO
Id:0900d805800d4321
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: NONE
PROCEDURAL STATUS: NONE
SYNE 1:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: NONE
PROCEDURAL STATUS: NONE
SYNC 0:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: PROVIDING_SERVICE
PROCEDURAL STATUS: NONE
TRAU NR: 1
SYNC SOURCE: MSC
SYNC PCMA: 3
LICD CIRCUIT: 9 - 5 (LICD NR - CIRC NR)
WORKING MODE: DOUBLE_TRUNK
USED TRUNK: TRUNK_A
SYNC 1:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: HOT_STANDBY
PROCEDURAL STATUS: NONE
TRAU NR: 2
SYNC SOURCE: FREE_RUNNING


1380 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4321
SYNCO
SYNC PCMA: 12
LICD CIRCUIT: 9 - 4 (LICD NR - CIRC NR)
WORKING MODE: SINGLE_TRUNK
USED TRUNK: TRUNK_A
... ...
SYNC 35:
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
CONTROL STATUS: NONE
STANDBY STATUS: HOT_STANDBY
PROCEDURAL STATUS: NONE

TRAU NR: 0
SYNC SOURCE: BSC
SYNC PCMA: 6
LICD CIRCUIT: 9 - 1 (LICD NR - CIRC NR)
WORKING MODE: DOUBLE_TRUNK
USED TRUNK: TRUNK_A
END OF REPORT
- Operation Failed
GETINFO SYNC NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack SYNC:
name = SYNC:0
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1381
CML:BSC SYNCO
Id:0900d805800d4321
Application Guidelines:
The possible values for the attribute SYNC-MODE can be:
"SYNC", when the synchronism source is external (SYNC or SYNE).
"ASYNC_ON_TUNE", when the PLLH generates internally the synchronism from
DAC value.
"SLAVE", when the PLLH receives the synchronism from the other PLLH card.
The attributes FREQ, ELAPSED-TIME, PH and ERR represent if the PLLH is master
and only when the value of the attribute SYNC-MODE is "SYNC".
Example of Command Execution:
Getinfo SYNCO:NAME=SYNCO:0;
T_REQUEST_ALREADY_IN_PROGRESS
If another GetInfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 GetInfo commands already in progress.


1382 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4324
SYNE
SYNE
The SYNE object is the external synchronization source which may be connected to the
BSC clock by the operator.
CREATE SYNE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE CREATE SYNE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds an external synchronization signal source (SYNE) to the system.
The signal is directly connected to one of the two external input accesses of the PLLH
card.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. Before submitting the command the relevant hardware has to be plugged in the
proper slot.
2. This synchronization source has higher priority than SYNC synchronization source.
3. After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. The UNLOCK command is required to put this object in service.
Example of Command Execution:
Create SYNE:NAME=SYNE:0
CREATE SYNE NAME=SYNE:0..1;
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created
in order to perform the command.


A30808-X3247-M230-6-7619

1383
CML:BSC SYNE
Id:0900d805800d4324
DELETE SYNE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE DELETE SYNE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes an external synchronization signal source (SYNE) previously
created through the CREATE SYNE command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
The relevant hardware can be unplugged after submitting the command.
Example of Command Execution:
Delete SYNE:NAME=SYNE:0
FREQMEAS SYNE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE FREQMEAS SYNE
Applicability:
Phase 1 and Phase 2.
DELETE SYNE NAME=SYNE:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a SYNE, the relative object instance must
be in LOCKED state.
FREQMEAS SYNE NAME=SYNE:0..1 ,DUR=;


1384 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4324
SYNE
Visibility level: 2.
Command Description:
This command allows to perform a frequency measurement over a specified syne
source and report the measurement performed by the system before having selected a
certain source of synchronism.
Long Names:
NAME Addres of the managed object
DUR duration
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
A spontaneous message is the normal consequence of this command. The message is
MEASSYNESPN with three values associated: K and E that form the frequency error
like Kx10-E and the phase error P between this source and the current source of syn-
chronism.
Example of Command Execution:
Freqmeas SYNE:NAME=SYNE:1,DUR=17;
GET SYNE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE GET SYNE
Applicability:
Phase 2.
Successful
The command has been accepted; a measurement REPORT will
follow or an error will be issued.
UNSUCCESSFUL_HW_FAILURE
Hardware problems during the execution of the command.
INVALID_CONDITION_FOR_MEASUREMENT
The NTW copy is not in the correct state.
The NTW copy that has to perform the command must be
UNLOCKED/ENABLED/HOT-STANDBY.
GET SYNE NAME=SYNE:0..1;


A30808-X3247-M230-6-7619

1385
CML:BSC SYNE
Id:0900d805800d4324
Visibility level: 0.
Command Description:
This command is used to retrieve the EQUIPPED state of the external synchronization
signal source (SYNE) previously created through the CREATE SYNE command.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get SYNE:NAME=SYNE:0;
GET SYNE STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE GET SYNE STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
SYNE object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Standby Status (STNDBY)
NAME: name
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET SYNE STAT NAME=SYNE:0..1;


1386 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4324
SYNE
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get SYNE STAT:NAME=SYNE:0;
LOCK SYNE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE LOCK SYNE
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK SYNE NAME=SYNE:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.


A30808-X3247-M230-6-7619

1387
CML:BSC SYNE
Id:0900d805800d4324
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock SYNE:NAME=SYNE:0;
UNLOCK SYNE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL SYNE UNLOCK SYNE
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
STANDBY_PLLH_DAC_WORD_EVOLVING
It is emitted when the PLLH has become synchronized to an
external source little time ago, and the switch of the master PLLH
(for LOCK or SWITCH command) would leave the frequency of
the new active PLLH with a bad value; it can be answered up to
5 minutes after a SYNC or SYNE has gone PROVIDING
SERVICE. The same can happen if less than 5 minutes have
passed since last switch of NTW.
UNLOCK SYNE NAME=SYNE:0..1;


1388 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4324
SYNE
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock SYNE:NAME=SYNE:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1389
CML:BSC SYSINIT
Id:0900d805800d4327
SYSINIT
The SYSINIT (System Initialization) allows different types of system initializations.
Only 1 instance is allowed.
SYSINIT SYSINIT
Command Tree:
MANAGED-ELEMENT SOFTWARE-MANAGEMENT SYSINIT SYSINIT
SYSINIT
Applicability:
Phase 2.
Visibility level: 3.
Command Description:
This command allows the system to restart the software from a known state. A
command acknowledge is requested by the system by means of a window CLI message
("SYSINIT SYSINIT:SYSINIT:0...EXECUTE COMMAND?"); if OK is selected, the
command will be executed.
Long Names:
NAME Addres of the managed object
INITLEV initLevel
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
SYSINIT SYSINIT NAME=SYSINIT:0..0 ,INITLEV=;
NAME: name
INITLEV: initLevel
CMND_REJECTED_DUE_OTHER_CMND_IN_PROGRESS
Patch loading is in progress.
Change Version operation is in progress.
Save Data Base operation is in progress.


1390 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4327
SYSINIT
Application Guidelines:
1. To perform SYSINT command with INITLEV equal to TASK_PRIME the operational
preconditions are the following:
no Change Version operation must be in progress;
no patch loading operation must be in progress;
no Database saving operation is in progress.
2. When INITLEV option is set at FULL value, there are no operational preconditions,
but if the command is performed during a Bring Up or a Change Version Bring Up,
the system initialization is automatically upgraded to INITLEV=BU_ACTIVE
otherwise the FULL is performed as soon as possible (system must be in normal
exercise).
3. If the INITLEV option is set at BU_ACTIVE value, there are no operational
preconditions; in this case the command forces the MPCC re-loading.
4. Note that the SYSINIT command must only be used as the last recovery action in all
the cases in which the BSC behaviour is out of control and doesn't respond to the
usual commands. Before using the SYSINIT command check that the backup
BSCESUSW is ENABLED. If this condition is not fulfilled you will lose the RC con-
nection to the BSC.
Example of Command Execution:
Sysinit SYSINIT:NAME=SYSINIT:0,INITLEV=BU_ACTIVE;


A30808-X3247-M230-6-7619

1391
CML:BSC TDPC
Id:0900d805800d432b
TDPC
The TDPC object is the telephonic processor of the BSS system. It is a redundant unit
in the active/standby mode; it is under the control of MPCC.
GET TDPC STAT
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GET TDPC STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
BTSM object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Stnadby Status (STNDBY)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get TDPC STAT:NAME=TDPC:0;
GET TDPC STAT NAME=TDPC:0..1;


1392 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432b
TDPC
GETINFO TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETINFO TDPC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The "RSU running" object and the "RSU version".
2. For each TDPC card:
the firmware version
the states and statuses: AST, OST, STNDBYST, PRS.
the MAC0 and MAC1 fields.
3. The board version: old or new.
4. The active processor operational data (Peak Detection, Mobile Average and
Variance for several types of processor data).
5. The operational data of the active processor: real time, current OS time, OS time of
last Task init, type and OS time of the last exception, number of task init from last
full, number of full init from last bring-up, the exception number from last task, full
and bring-up init.
6. For all dynamic memory pool type: the used and total buffer number.
7. Total and largest block available.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO TDPC ACK:
BSC_CONTROLLER -> LMT_LOCAL
02:30:41 02/01/1992
*** INFORMATION ***
GETINFO REPORT TDPC:
NAME = TDPC:0
RSU RUNNING: RSUEXE 0-1
RSU VERSION: 02-06-01-01-00-00_00-01-10
GETINFO TDPC NAME=TDPC:0..1;


A30808-X3247-M230-6-7619

1393
CML:BSC TDPC
Id:0900d805800d432b
TDPC 0:
FIRMWARE VERSION: SFM1101
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
STANDBY STATUS: PROVIDING_SERVICE
PROCEDURAL STATUS: NONE
MAC0: 123:12:34:56:77:00
MAC1: 123:122:34:56:77:00
TDPC 1:
FIRMWARE VERSION: SFM1101
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
STANDBY STATUS: HOT_STANDBY
PROCEDURAL STATUS: NONE
MAC0: 123:12:34:56:77:00
MAC1: 123:122:34:56:77:00

PROCESSOR TYPE: NEW_BOARD_VERSION

ACTIVE PROCESSOR OPERATIONAL DATA:
REAL TIME LOAD: 31%
CURRENT OS TIME: 0049:05:54
OS TIME OF LAST TASK INIT: 0000:00:00
OS TIME OF LAST EXCEPTION: 0000:00:00
TYPE OF LAST EXCEPTION: 244
NUMBER OF TASK INIT SINCE LAST FULL INIT: 0001
NUMBER OF FULL INIT SINCE LAST BRING-UP: 0001
NUMBER OF EXCEPTION SINCE LAST TASK INIT: 0000
NUMBER OF EXCEPTION SINCE LAST FULL INIT: 0000
NUMBER OF EXCEPTION SINCE LAST BRING-UP INIT: 0000
DYNAMIC MEMORY USAGE:
0: 0017/0050 1: 0057/0100 2: 0019/0064 3: 0012/0030 4: 0017/0031
5: 0000/0001 6: 0000/0001 7: 0001/0068 8: 0002/0200 9: 0000/0070
A: 0000/0014
TOTAL AND LARGEST BLOCK AVAILABLE: 00000001/00022344


1394 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432b
TDPC
END OF REPORT
- Operation Failed
GETINFO TDPC NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack TDPC:
name = TDPC:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
The attribute "TYPE OF LAST EXCEPTION" is reserved for the developer.
Example of Command Execution:
Getinfo TDPC:NAME=TDPC:0;
GETRELATIONSHIP TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETRELATIONSHIP
TDPC
Applicability:
Phase 2.
Visibility level: 1.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
GETRELATIONSHIP
TDPC
NAME=TDPC:0..1;


A30808-X3247-M230-6-7619

1395
CML:BSC TDPC
Id:0900d805800d432b
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.

For the TDPC object the MEL is the related FMO.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship TDPC:NAME=TDPC:0;
GETSUBO TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETSUBO TDPC
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
UNSUCCESSFUL_INVALID_ATTRIBUTES
The object instance does not provide any relationship attribute.
GETSUBO TDPC NAME=TDPC:0..1;


1396 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432b
TDPC
The output of the command can be composed by one or more packs with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo TDPC:NAME=TDPC:0;
GETTEST TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC GETTEST TDPC
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the values of all the attributes belonging to a specified
test object; the test object is created by the system as a result of a request to start a test
and it is deleted when the test terminates.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETTEST TDPC NAME=TDPC:0..1;
GETTEST TDPC:NAME=TDPC:0;
name = TEST:<n>
mOts = TDPC:0
testState = It can assume one of the following values:
not_initialized, idle, initializing, suspended, testing,
terminating and disabled.
testOutcome = It represents the test result: it can be Inconclusive
(meaning-less: that is if the phases already
executed were successful) or Fail (if at least one of
the executed phases failed).
testMonitor


A30808-X3247-M230-6-7619

1397
CML:BSC TDPC
Id:0900d805800d432b
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Gettest TDPC:NAME=TDPC:0;
LOCK TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC LOCK TDPC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
The command can be rejected due to high criticity of the system state.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
phaseId = It is a list of the phases to execute and their status
that can be: pass, fail, running or waiting.
phaseStatus =
phaseId =
phaseStatus =
...
.
NO_SUCH_TEST
The test is not active.
UNSUCCESSFUL_WRONG_ME_ID
The object address is incorrect.
LOCK TDPC NAME=TDPC:0..1;


1398 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432b
TDPC
NACK CAUSES:
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock TDPC:NAME=TDPC:0;
PERFTEST TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC PERFTEST TDPC
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
CRITICAL_ALARM_REJECTED
The command has been rejected due to high criticity of the
system state.
STANDBY_PLLH_DAC_WORD_EVOLVING
It is emitted when the PLLH has become synchronized to an
external source little time ago, and the switch of the master
PLLH (for LOCK or SWITCH command) would leave the fre-
quency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone
PROVIDING SERVICE. The same can happen if less than 5
minutes have passed since last switch of NTW.
PERFTEST TDPC NAME=TDPC:0..1;


A30808-X3247-M230-6-7619

1399
CML:BSC TDPC
Id:0900d805800d432b
Command Description:
This command is used to perform a test on the selected TDPC object; the test consists
of the following phases:
Accessibility Test (start phase),
Test MEMT Availability (WP1),
Test Alarm Circuit - via MEMT (WP2),
Test Alarm Circuit - via TDPC (WP3),
End Test (end phase).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
PERFTEST TDPC:NAME=TDPC:0;
testObject=TEST:<n>
The test results will be displayed at the end of the test phases.
Result TEST:
name = TEST:<n>
testOutcome = This field represents the test result; one of the fol-
lowing values can be displayed:
Pass all the test phases are successfully
performed.
Inconclusive the test is aborted by the system or
the test is terminated by the opera-
tor.
Fail if at least one of the executed phases
fail.
mOts = It is the identifier of the hardware object under test.
testTermination = It specifies how the test is terminated, it can assume
the following values:
Normal all the test phases are performed.
Abort the test is aborted by system.
Cancel the test is terminated by operator.
executedPhases
phaseId = It represents the list of the executed test phases (in
case of successful test result, all the test phases will
be listed).
additionalWords =
....
failedPhases


1400 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432b
TDPC
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The unit to be diagnosed must be set, through the LOCK command, to the LOCKED
state, if the diagnostic is intrusive.
2. When a test starts on one object, this one goes in "Locked Disabled/Reserved for
test" state. When the test result is:
"fail" the object goes in "Disabled / Failed" operational state;
"pass" the object goes in "Enabled" operational state;
"inconclusive" the object returns to the operational state previous to the test or
in "Enabled" operational state.
Example of Command Execution:
Perftest TDPC:NAME=TDPC:0;
STOPTEST TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC STOPTEST TDPC
Applicability:
Phase 2.
Visibility level: 2.
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases; they are
displayed only for test stopped during it execution.
phaseId =
....
poprosedRepair Action
=
A list of most probable fail probable causes is shown
(max four messages)
MOTS_NOT_LOCKED
The selected object is not in LOCKED administrative state.
OTHER_TESTS_RUNNING
Other incompatible tests are already running or no more parallel exe-
cution of tests are possible.
STOPTEST TDPC NAME=TDPC:0..1;


A30808-X3247-M230-6-7619

1401
CML:BSC TDPC
Id:0900d805800d432b
Command Description:
This command allows to terminate the test previously requested; the test can be in
progress or in the waiting list (queued).
In the first case the process that execute the diagnostic will be interrupted by executing
the end phase; in the second case the test will be removed from the waiting list.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
STOPTEST TDPC:NAME=TDPC:0;
testObject=TEST:<n>
Result TEST:
name = TEST:<n>
testOutcome = inconclusive
mOts = TDPC:0
testTermination = Cancel
executedPhases
phaseId = It represents the list of the executed test phases; the
list is not shown for test in the waiting list (queued).
...
.
failedPhases
phaseId = It represents the list of the failed test phase;
additional information is provided for each phase.
phaseId =
....
skippedPhases
phaseId = It represents the list of the skipped phases;the list is
not shown for test in the waiting list (queued).
phaseId =
...
.
NO_SUCH_TEST
The test is not active.
UNABLE_TO_STOP_TEST
The test can not be stopped.


1402 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432b
TDPC
Application Guidelines:
None.
Example of Command Execution:
Stoptest TDPC:NAME=TDPC:0;
SWITCH TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC SWITCH TDPC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows the standby status exchange of the duplicated objects from "Pro-
viding Service" to "Hot Standby" and viceversa.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
SWITCH TDPC NAME=TDPC:0..1;
ALREADY_IN_TARGET_STATE
OTHER_COPY_INVALID_STATE
UNSUCCESSFUL_COMMAND_REJECTED
STANDBY_PLLH_DAC_WORD_EVOLVING
It is emitted when the PLLH has become synchronized to an
external source little time ago, and the switch of the master
PLLH (for LOCK or SWITCH command) would leave the fre-
quency of the new active PLLH with a bad value; it can be
answered up to 5 minutes after a SYNC or SYNE has gone
PROVIDING SERVICE. The same can happen if less than 5
minutes have passed since last switch of NTW.


A30808-X3247-M230-6-7619

1403
CML:BSC TDPC
Id:0900d805800d432b
Application Guidelines:
1. The selected object must be equipped and in "enabled-providing service" state and
its duplicated copy must be in "enable-cold/hot standby" state.
2. It is not possible to enter more than one SWITCH TDPC command per minute.
3. The network switch command cannot be performed within 5 minutes from the
previous one if a SYNC or SYNE object is configured due to hardware constraints.
Example of Command Execution:
Switch TDPC:NAME=TDPC:0;
UNLOCK TDPC
Command Tree:
MANAGED-ELEMENT BSS-EQUIPMENT BSCE TDPC UNLOCK TDPC
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. Unlocking of BTSM causes a full BTS alignment.
2. It is possible to unlock the TDPC card with the status in LOCKED and UNDER
TEST.
Example of Command Execution:
Unlock TDPC:NAME=TDPC:0;
UNLOCK TDPC NAME=TDPC:0..1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.


1404 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
TGTBTS
The TGTBTS (Target BTS) managed object instance contains a copy of the attributes
involved in the management of the adjacency of an external BTS. Once a TGTBTS is
configured it is treated by the system, for the management of the adjacencies, as the
other internal target BTSs.
This means that, in the case in which the external target BTS is adjacent to more than
one internal serving BTS, it is no more necessary to replicate all the attribute values in
every ADJC managed object instance, but it is enough that the different ADJCs refer to
the same TGTBTS.
CREATE TGTBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS CREATE TGTBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to create a target BTS object used to manage the adjacency.
This object will be selected by means of the TGTCELL parameter of the ADJC object.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
BCCHFREQ bcchFrequency
SYSID systemIndicator
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
CELLRESH cellReselectHysteresis
RXLEVAMI rxLevAccessMin
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
CREATE TGTBTS NAME=TGTBTS:0..1499 ,CELLGLID= ,BSIC= ,BCCH-
FREQ= ,SYSID= [,MSTXPMAXGSM=] [,MSTXPMAXDCS=]
[,MSTXPMAXPCS=] [,CELLRESH=] [,RXLEVAMI=]
[,CRESPARI=] [,CRESOFF=] [,TEMPOFF=] [,PENTIME=]
[,CBQ=] [,MSTXPMAXCH=] [,CELLBARR=];


A30808-X3247-M230-6-7619

1405
CML:BSC TGTBTS
Id:0900d805800d432e
PENTIME penaltyTime
CBQ cellBarQualify
MSTXPMAXCH msTxPwrMaxCcch
CELLBARR cellBarred
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. Three attributes in the TGTBTS object are formatted in digits.
The attributes are:
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
For more details, see Application Guidelines n. 1 and n. 3.
UNSUCCESSFUL_CELL_GLOB_ID
All the fields (MCC, MNC, LAC, CI) of cellGlobalIdentity must be set.
The CELLGLID cannot be equal to the CELLGLID assigned to other
adjacent cells (ADJC) and to the serving cell (BTS).
The CELLGLID cannot be equal to the CELLGLID assigned to
another BTS or TGTBTS.
BCCF_AND_BSIC_BELONG_TO_ANOTHER_CELL
ARFCN (bcchFrequency) and BSIC (bsIdentityCode) set values
must not belong to another adjacent cell of the BTS.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
One or more variables have been incorrectly set.
For more details see Application Guideline n. 4.
WRONG_SYSID
The value set for the SYSID parameter is incorrect.
For more details, see Application Guideline n. 5.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE
The selected frequency is out of range.
For more details, see Application Guideline n. 6.


1406 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained
in the CellGlobalId (CELLGLID)
the bSIdentityCode (BSIC)
2. Location Area Identity (LAI) = MCC + MNC + LAC
Cell Global Identity = LAI + CI
3. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS and MSTXPMAXPCS
can be set only if the SYSID refers to the corresponding band; otherwise they must
be skipped or assume the value <NULL>.
4. For the different SYSID setting, the following "msTxPwrMax" parameters must be
used:
If SYSID equals BB900, EXT900, GSMDCS, GSMR, GSM850, GSM850PCS or
GSM850DCS the MSTXPMAXGSM must be set.
If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS
must be set.
If SYSID equals PCS1900 or GSM850PCS the MSTXPMAXPCS must be set.
If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSM must be set
at 2..15 (for the GSM part of the cell), and the MSTXPMAXDCS must be set at
0..15 (for the DCS part of the cell).
If SYSID equals GSM850PCS the MSTXPMAXGSM must be set at 2..15 (for the
GSM part of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31
(for the PCS part of the cell).
5. The SYSID parameter can assume 10 values:
BB900 (GSM Standard Band);
EXT900 (GSM Mixed Band)
GSMR (Railway Band)
CELLGLID = MCC-MNC-LAC-CI
Note that: MCC = D1D2D3
MNC = D1D2D3
Dx means digit (only numerical characters shall be used; for numbers from 0 to
9 it must be entered one digit). In fact 9 is different from 09. For MCC and MNC
all digits are mandatory.
BSIC = D1D2
Dx means digit (only numerical characters 0..7 shall be used)
Note that D1 is the NetworkColourCode (NCC) and D2 is the
BTSColourCode (BCC)
These attributes are stored in the system in their decimal representation (which
is the input format) but it is necessary to check the range of each digit:
MCC, MNC 0 =< Dx =< 9
BSIC 0 =< Dx =< 7


A30808-X3247-M230-6-7619

1407
CML:BSC TGTBTS
Id:0900d805800d432e
PCS1900
DCS1800
GSMDCS
GSM850
GSM850PCS
GSM850DCS
If the NETWTYPE parameter (previously set by the SET BSC command) is
GSMDCS then only the BB900, EXT900, DCS1800 and GSMDCS values are per-
mitted to the SYSID.
If the NETWTYPE parameter is GSMR then only the GSMR value is permitted to the
SYSID.
If the NETWTYPE parameter is GSMPCS then only the BB900, EXT900 and
PCS1900 values are permitted to the SYSID.
If the NETWTYPE parameter is GSM850PCS then only GSM850, GSM850PCS and
PCS1900 values are permitted to the SYSID.
If the NETWTYPE parameter (previously set by the SET BSC command) is
GSM850DCS then only GSM850, GSM850DCS and DCS1800 values are permitted
to the SYSID.
6. The BCCHFREQ attribute must follow these rules:
7. Regarding the number of allowed TGTBTS instances the following rules are valid:
if SYSID = BB900 then 1 =< BCCHFREQ =< 124
if SYSID = EXT900 then 0 =< BCCHFREQ =< 124
975 =< BCCHFREQ =< 1023
if SYSID = DCS1800 then 512 =< BCCHFREQ =< 885
if SYSID = GSMR then 955 =< BCCHFREQ =< 974
if SYSID = PCS1900 then 512 =< BCCHFREQ =< 810
if SYSID = GSMDCS then 0 = < BCCHFREQ =< 124
975 = < BCCHFREQ =< 1023
(GSM extended band)
512 =< BCCHFREQ =< 885 (DCS 1800)
If SYSID = GSM850 then 128 =< BCCHFREQ =< 251
If SYSID = GSM850PCS then 128 =< BCCHFREQ =< 251
512 =< BCCHFREQ =< 810
If SYSID = GSM850DCS then 128 =< frequency =< 251 (GSM_850)
512 =< frequency =< 885 (DCS 1800)


1408 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
in case of MPCC V9 the sum: (number of TGTBTS) + (number of TGTTDD) +
(number of TGTFDD) must be <= 1500, and at most 1500 instances (0..1499)
can be created for all the three classes.
Example of Command Execution:
Create TGTBTS:NAME=TGTBTS:0,CELLGLID="123"-"45"-1-1,BSIC=1-2,
BCCHFREQ=35,SYSID=BB900,MSTXPMAXGSM=2,CELLRESH=2, RXLEVAMI=6,
CRESPARI=1, CRESOFF=4, TEMPOFF=4, PENTIME=5, CBQ=1, MSTXPMAXCH=5,
CELLBARR=FALSE;
DELETE TGTBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS DELETE TGTBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allow to delete a previously created TGTBTS object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete TGTBTS:NAME=TGTBTS:0;
DELETE TGTBTS NAME=TGTBTS:0..1499;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1409
CML:BSC TGTBTS
Id:0900d805800d432e
GET TGTBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS GET TGTBTS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the target BTS object.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
BCCHFREQ bcchFrequency
SYSID systemIndicator
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
CELLRESH cellReselectHysteresis
RXLEVAMI rxLevAccessMin
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
MSTXPMAXCH msTxPwrMaxCcch
CELLBARR cellBarred
System Responses:
- Operation Completed
GET TGTBTS NAME=TGTBTS:0..1499 [,REQATTL= CELLGLID ,BSIC
,BCCHFREQ ,SYSID ,MSTXPMAXGSM ,MSTXPMAXDCS
,MSTXPMAXPCS ,CELLRESH ,RXLEVAMI ,CRESPARI
,CRESOFF ,TEMPOFF ,PENTIME ,CBQ ,MSTXPMAXCH
,CELLBARR];
NAME: name
CELLGLID: cellGlobalIdentity


1410 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
GET TGTBTS BASICS
BSIC: bsIdentityCode
BCCHFREQ: bcchFrequency
SYSID: systemIndicator
MSTXP-
MAXGSM:
msTxPwrMaxGsm
MSTXPMAXDCS: msTxPwrMaxDcs
MSTXPMAXPCS: msTxPwrMaxPcs
CELLRESH: cellReselectHysteresis
RXLEVAMI: rxLevAccessMin
CRESPARI: cellReselectionParamInd
CRESOFF: cellReselectionOffset
TEMPOFF: temporaryOffset
PENTIME: penaltyTime
CBQ: cellBarQuality
MSTXPMAXCH: msTxPwrMaxCcch
CELLBARR: cellBarred
NAME: name
CELLGLID: cellGlobalIdentity
BSIC: bsIdentityCode
BCCHFREQ: bcchFrequency
SYSID: systemIndicator
MSTXP-
MAXGSM:
msTxPwrMaxGsm
MSTXPMAXDCS: msTxPwrMaxDcs
MSTXPMAXPCS: msTxPwrMaxPcs
CELLRESH: cellReselectHysteresis
RXLEVAMI: rxLevAccessMin
CRESPARI: cellReselectionParamInd
CRESOFF: cellReselectionOffset
TEMPOFF: temporaryOffset
PENTIME: penaltyTime
CBQ: cellBarQuality
MSTXPMAXCH: msTxPwrMaxCcch
CELLBARR: cellBarred


A30808-X3247-M230-6-7619

1411
CML:BSC TGTBTS
Id:0900d805800d432e
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TGTBTS BASICS
None.
Example of Command Execution:
Get TGTBTS:NAME=TGTBTS:0,REQATTL=CELLGLID&BSIC&BCCHFREQ&
SYSID&MSTXPMAXGSM&MSTXPMAXDCS&MSTXPMAXPCS&CELLRESH&RXLE-
VAMI&CRESPARI&CRESOFF&TEMPOFF&PENTIME&CBQ&MSTXPMAXCH&CELL-
BARR;
GET TGTBTS BASICS
Get TGTBTS BASICS:NAME=TGTBTS:0;
GET TGTBTS BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS GET TGTBTS BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters, selected by the operator,
related to the target BTS object.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
BCCHFREQ bcchFrequency
SYSID systemIndicator
MSTXPMAXGSM msTxPwrMaxGsm
MSTXPMAXDCS msTxPwrMaxDcs
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET TGTBTS BASICS NAME=TGTBTS:0..1499;


1412 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
MSTXPMAXPCS msTxPwrMaxPcs
CELLRESH cellReselectHysteresis
RXLEVAMI rxLevAccessMin
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
MSTXPMAXCH msTxPwrMaxCcch
CELLBARR cellBarred
System Responses:
See GET TGTBTS
Application Guidelines:
See GET TGTBTS
Example of Command Execution:
See GET TGTBTS
SET TGTBTS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS SET TGTBTS
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to modify the specific parameters for a target BTS object.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
BSIC bsIdentityCode
BCCHFREQ bcchFrequency
SYSID systemIndicator
MSTXPMAXGSM msTxPwrMaxGsm
SET TGTBTS NAME=TGTBTS:0..1499 [,CELLGLID=] [,BSIC=] [,BCCH-
FREQ=] [,SYSID=] [,MSTXPMAXGSM=] [,MSTXP-
MAXDCS=] [,MSTXPMAXPCS=] [,CELLRESH=]
[,RXLEVAMI=] [,CRESPARI=] [,CRESOFF=] [,TEMPOFF=]
[,PENTIME=] [,CBQ=] [,MSTXPMAXCH=] [,CELLBARR=];


A30808-X3247-M230-6-7619

1413
CML:BSC TGTBTS
Id:0900d805800d432e
MSTXPMAXDCS msTxPwrMaxDcs
MSTXPMAXPCS msTxPwrMaxPcs
CELLRESH cellReselectHysteresis
RXLEVAMI rxLevAccessMin
CRESPARI cellReselectionParamInd
CRESOFF cellReselectionOffset
TEMPOFF temporaryOffset
PENTIME penaltyTime
CBQ cellBarQualify
MSTXPMAXCH msTxPwrMaxCcch
CELLBARR cellBarred
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
One or more attributes have been incorrectly set.
For more details, see Application Guidelines n. 1 and n. 3.
UNSUCCESSFUL_CELL_GLOB_ID
All the fields (MCC, MNC, LAC, CI) of cellGlobalIdentity must be set.
The CELLGLID cannot be equal to the CELLGLID assigned to other
adjacent cells (ADJC) and to the serving cell (BTS).
The CELLGLID cannot be equal to the CELLGLID assigned to
another BTS or TGTBTS.
BCCF_AND_BSIC_BELONG_TO_ANOTHER_CELL
ARFCN (bcchFrequency) and BSIC (bsIdentityCode) set values
must not belong to another adjacent cell of the BTS.
UNSUCCESSFUL_BCCF_OUT_OF_RANGE
The selected BCCF is not allowed for the selected SYSID value.
UNSUCCESSFUL_FREQUENCY_UNDER_MEASURE
The BCCH frequency cannot be changed if the TGTBTS is the target
cell of an ADJC which has its BCCH frequency traced by the relative
SCA (see NMDLATT <nn> parameter of the SCA object).
UNSUCCESSFUL_VAR_OUT_RANGE


1414 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
Application Guidelines:
1. Three attributes in the TGTBTS object are formatted in digits.
The attributes are:
One or more variables have been incorrectly set.
For more details, see Application Guideline n. 4.
WRONG_SYSID
The value set for the SYSID parameter is incorrect.
For more details, see Application Guideline n. 5.
UNSUCCESSFUL_FREQ_OUT_OF_RANGE
The selected frequency is out of range.
For more details, see Application Guideline n. 6.
MAX_ADJC_COMPL_BAND_EXCEEDED
The number of the adjacent cells having their BCCHFREQ in the
complementary band exceeds the allowed maximum number.
For more details, see Application Guideline n. 7.
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The maximum number of different frequencies of adjacent cells that
can be included in System Information 5 is:
- 30, if LOTRACH=FALSE in HAND object and one or more
ADJC3Gs are equipped;
- 31, if LOTRACH=FALSE in HAND object and no ADJC3Gs are
equipped;
- 31, if LOTRACH=TRUE in HAND object and one or more ADJC3Gs
are equipped.
-32, otherwise.
UNSUCCESSFUL_INVALID_BCCF
The target cell and the serving cell must have different BCCH fre-
quencies when the target cell is different from the serving cell.


A30808-X3247-M230-6-7619

1415
CML:BSC TGTBTS
Id:0900d805800d432e
the MobileCountryCode (MCC) and the MobileNetworkCode (MNC) contained
in the CellGlobalId (CELLGLID)
the bSIdentityCode (BSIC)
2. Location Area Identity (LAI) = MCC + MNC + LAC
Cell Global Identity = LAI + CI
3. Each of the attributes MSTXPMAXGSM, MSTXPMAXDCS and MSTXPMAXPCS
can be set only if the SYSID refers to the corresponding band; otherwise they must
be skipped or assume the value <NULL>.
4. For the different SYSID setting, the following "msTxPwrMax" parameters must be
used:
If SYSID equals BB900, EXT900, GSMDCS, GSMR, GSM850, GSM850PCS or
GSM850DCS the MSTXPMAXGSM must be set.
If SYSID equals DCS1800, GSMDCS or GSM850DCS the MSTXPMAXDCS
must be set.
If SYSID equals PCS1900 or GSM850PCS the MSTXPMAXPCS must be set.
If SYSID equals GSMDCS or GSM850DCS the MSTXPMAXGSM must be set
at 2..15 (for the GSM part of the cell), and the MSTXPMAXDCS must be set at
0..15 (for the DCS part of the cell).
If SYSID equals GSM850PCS the MSTXPMAXGSM must be set at 2..15 (for the
GSM part of the cell), and the MSTXPMAXPCS must be set at 0..15, 30 or 31
(for the PCS part of the cell).
5. The SYSID parameter can assume 10 values:
BB900 (GSM Standard Band);
EXT900 (GSM Mixed Band)
GSMR (Railway Band)
CELLGLID = MCC-MNC-LAC-CI
Note that: MCC = D1D2D3
MNC = D1D2D3
Dx means digit (only numerical characters shall be used; for numbers from 0 to
9 it must be entered one digit). In fact 9 is different from 09. For MCC and MNC
all digits are mandatory.
BSIC = D1D2
Dx means digit (only numerical characters 0..7 shall be used)
Note that D1 is the NetworkColourCode (NCC) and D2 is the
BTSColourCode (BCC)
These attributes are stored in the DBC in their decimal representation (which is
the input format) but it is necessary to check the range of each digit:
MCC,MNC 0 =< Dx =< 9
BSIC 0 =< Dx =< 7


1416 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d432e
TGTBTS
PCS1900
DCS1800
GSMDCS
GSM850
GSM850PCS
GSM850DCS
If the NETWTYPE parameter (previously set by the SET BSC command) is
GSMDCS then only the BB900, EXT900, DCS1800 and GSMDCS values are per-
mitted to the SYSID.
If the NETWTYPE parameter is GSMR then only the GSMR value is permitted to the
SYSID.
If the NETWTYPE parameter is GSMPCS then only the BB900, EXT900 and
PCS1900 values are permitted to the SYSID.
If the NETWTYPE parameter is GSM850PCS then only GSM850, GSM850PCS and
PCS1900 values are permitted to the SYSID.
If the NETWTYPE parameter is GSM850DCS then only GSM850, GSM850DCS
and DCS1800 values are permitted to the SYSID.
6. The BCCHFREQ attribute must follow these rules:
7. The maximum number of adjacent cells having their BCCHFREQ in the complemen-
tary band, with respect to the SYSID of the serving cell, depends on the delta
if SYSID = BB900 then 1 =< BCCHFREQ =< 124
if SYSID = EXT900 then 0 =< BCCHFREQ =< 124
975 =< BCCHFREQ =< 1023
if SYSID = DCS1800 then 512 =< BCCHFREQ =< 885
if SYSID = GSMR then 955 =< BCCHFREQ =< 974
if SYSID = PCS1900 then 512 =< BCCHFREQ =< 810
if SYSID = GSMDCS then 0 = < BCCHFREQ =< 124
975 = < BCCHFREQ =< 1023
(GSM extended band)
512 =< BCCHFREQ =< 885 (DCS 1800)
If SYSID = GSM850 then 128 =< BCCHFREQ =< 251
If SYSID = GSM850PCS then 128 =< BCCHFREQ =< 251
512 =< BCCHFREQ =< 810
if SYSID = GSM850DCS then 128 =< BCCHFREQ =< 251
512 =< BCCHFREQ =< 885 (DCS 1800)


A30808-X3247-M230-6-7619

1417
CML:BSC TGTBTS
Id:0900d805800d432e
between the lowest and the highest frequency of the ADJCs belonging to this
subset, as shown in the following table.
Example of Command Execution:
Set TGTBTS:NAME=TGTBTS:0,CELLGLID="123"-"45"-1-1,BSIC=1-2,
BCCHFREQ=35,SYSID=DCS1800,MSTXPMAXDCS=0, CELLRESH=2, RXLE-
VAMI=6, CRESPARI=1, CRESOFF=4, TEMPOFF=4, PENTIME=5, CBQ=1, MSTXP-
MAXCH=5, CELLBARR=FALSE;
Max Number of ADJC in
complementary Band
Delta
16 Any
17 Any, if frequency 0 is present
18 512
22 256
29 128
All 111 or frequency in BB900 band


1418 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4331
TGTFDD
TGTFDD
CREATE TGTFDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD CREATE TGTFDD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to create a target FDD object.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
FDDARFCN fddArfcn
RNCID rncId
FDDSCRMC fddScramblingCode
FDDDIV fddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE TGTFDD NAME=TGTFDD:0..1499 ,CELLGLID= ,FDDARFCN=
,RNCID= ,FDDSCRMC= ,FDDDIV= [,MSTXPMAXUMTS=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_CELL_GLOB_ID
All the fields of CELLGLID attribute must be set.
The CELLGLID fields are not in correct format.
The pair CELLGLID and RNCID has been already used.
UNSUCCESSFUL_INVALID_ATTRIBUTES


A30808-X3247-M230-6-7619

1419
CML:BSC TGTFDD
Id:0900d805800d4331
Application Guidelines:
Regarding the number of allowed TGTFDD instances the following rules are valid:
in case of MPCC V9 the sum: (number of TGTBTS) + (number of TGTTDD) +
(number of TGTFDD) must be <= 1500, and at most 1500 instances (0..1499) can
be created for all the three classes.
Example of Command Execution:
Create TGTFDD:NAME=TGTFDD:0,CELLGLID="123"-"456"-1-1,
FDDARFCN=9662,RNCID=0,FDDSCRMC=2,FDDDIV=NO_DIVERSITY,
MSTXPMAXUMTS=49;
DELETE TGTFDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD DELETE TGTFDD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the TGTFDD object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
FDDARFCN value is not included between 9662 and 9938 or
between 412 and 687 or between 10562 and 10838 or between
4357 and 4458.
FDDARFCN Range 412...687 allowed values are: 412, 437, 462,
487, 512, 537, 562, 587, 612, 637, 662, 687.
FDDARFCN Range 1007..1062 allowed values are: 1007, 1012,
1032, 1037, 1062, 1087.
DELETE TGTFDD NAME=TGTFDD:0..1499;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1420 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4331
TGTFDD
Application Guidelines:
None.
Example of Command Execution:
Delete TGTFDD:NAME=TGTFDD:0;
GET TGTFDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD GET TGTFDD
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the TGTFDD
object class.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
FDDARFCN fddArfcn
RNCID rncId
FDDSCRMC fddScramblingCode
FDDDIV fddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
- Operation Completed
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The TGTFDD object instance cannot be deleted if is referenced as the
target cell by any ADJC3G object instance.
GET TGTFDD NAME=TGTFDD:0..1499 [,REQATTL= CELLGLID
,FDDARFCN ,RNCID ,FDDSCRMC ,FDDDIV ,MSTXPMAX-
UMTS];
NAME: name
CELLGLID: cellGlobalIdentity
FDDARFCN: fddArfcn
RNCID: rncId
FDDSCRMC: fddScramblingCode


A30808-X3247-M230-6-7619

1421
CML:BSC TGTFDD
Id:0900d805800d4331
GET TGTFDD BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TGTFDD BASICS
None.
Example of Command Execution:
Get TGTFDD:NAME=TGTFDD:0,REQATTL=CELLGLID&FDDARFCN&
RNCID&FDDSCRMC&FDDDIV&MSTXPMAXUMTS;
GET TGTFDD BASICS
Get TGTFDD BASICS:NAME=TGTFDD:0;
GET TGTFDD BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD GET TGTFDD BASICS
Applicability:
Phase 2.
FDDDIV: fddDiversity
MSTXPMAXUMTS:msTxPwrMaxUmts
NAME: name
CELLGLID: cellGlobalIdentity
FDDARFCN: fddArfcn
RNCID: rncId
FDDSCRMC: fddScramblingCode
FDDDIV: fddDiversity
MSTXPMAXUMTS:msTxPwrMaxUmts
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET TGTFDD BASICS NAME=TGTFDD:0..1499;


1422 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4331
TGTFDD
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the TGTFDD
object class.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
FDDARFCN fddArfcn
RNCID rncId
FDDSCRMC fddScramblingCode
FDDDIV fddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
See GET TGTFDD
Application Guidelines:
See GET TGTFDD
Example of Command Execution:
See GET TGTFDD
SET TGTFDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTFDD SET TGTFDD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the TGTFDD object class.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
FDDARFCN fddArfcn
RNCID rncId
FDDSCRMC fddScramblingCode
SET TGTFDD NAME=TGTFDD:0..1499 [,CELLGLID=] [,FDDARFCN=]
[,RNCID=] [,FDDSCRMC=] [,FDDDIV=] [,MSTXPMAX-
UMTS=];


A30808-X3247-M230-6-7619

1423
CML:BSC TGTFDD
Id:0900d805800d4331
FDDDIV fddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set TGTFDD:NAME=TGTFDD:0,CELLGLID="123"-"456"-1-1,
FDDARFCN=9662,RNCID=0,FDDSCRMC=2,FDDDIV=NO_DIVERSITY,
MSTXPMAXUMTS=49;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_CELL_GLOB_ID
The CELLGLID fields are not in correct format.
The pair CELLGLID and RNCID has been already used.
UNSUCCESSFUL_INVALID_ATTRIBUTES
FDDARFCN value is not included between 9662 and 9938 or
between 412 and 687 or between 10562 and 10838 or between
4357 and 4458.
FDDARFCN Range 412...687 allowed values are: 412, 437, 462,
487, 512, 537, 562, 587, 612, 637, 662, 687.
FDDARFCN Range 1007..1062 allowed values are: 1007, 1012,
1032, 1037, 1062, 1087.
A BTS cannot have two FDD ADJC3Gs with the same
(FDDARFCN, FDDSCRMC) pair.
At least two digits must be set for MNC, three for MCC.


1424 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4334
TGTPTPPKF
TGTPTPPKF
The TGTPPKF (Target Point-To-Point Packet Frame) is hierarchically dependent by the
TGTBTS in the containment tree. A TGTPTPPKF managed object instance contains a
copy of the attributes, of an external PTPPKF, involved in the management of the
adjacency. Once a TGTPTPPKF is configured, it is treated by the system, for the man-
agement of the adjacencies, as the other internal target PTPPKFs.
Therefore, in case of internal adjacency, the TGTCELL will identify the PTPPKF target
through the reference to the superordinate BTS. In case of external adjacency, the
TGTCELL will identify the TGTPTPPKF target through the reference to the
superordinate TGTBTS.
CREATE TGTPTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF CREATE
TGTPTPPKF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to create a target PTPPKF object which identify the target cell that
belongs to a BSC different from that of the serving cell.
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
RACOL routingAreaColour
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
EDTMSUP enableDTMSupport
EEDGE enableEdge
System Responses:
- Operation Completed
Successful
- Operation Failed
CREATE TGTPTPPKF NAME=TGTBTS:0..1499/TGTPTPPKF:0..0 ,RACODE=
,RACOL= [,GRXLAMI=] [,GMSTXPMAC=] [,EDTMSUP=]
[,EEDGE=];


A30808-X3247-M230-6-7619

1425
CML:BSC TGTPTPPKF
Id:0900d805800d4334
NACK CAUSES:
Application Guidelines:
If the GPRS service is present in the cells, the order of creation of the objects involved
in the adjacency management is the following:
The target TGTBTS has no superordinated.
The target TGTPTPPKF has to be created only after the creation of the superordi-
nated TGTBTS.
The serving PTPPKF has to be created only after the creation of the superordinated
serving BTS.
An ADJC, related to an external BTS target, has to be created only after the creation
of the superordinated serving BTS and the related serving PTPPKF, target TGTBTS
and target TGTPTPPKF.
Example of Command Execution:
Create TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0,RACODE=22,
RACOL=0,GRXLAMI=0,GMSTXPMAC=2;
DELETE TGTPTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF DELETE
TGTPTPPKF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the TGTPTPPKF object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The TGTBTS object instance must be already created.
DELETE TGTPTPPKF NAME=TGTBTS:0..1499/TGTPTPPKF:0..0;


1426 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4334
TGTPTPPKF
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0;
GET TGTPTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF GET
TGTPTPPKF
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
TGTPTPPKF object class.
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
RACOL routingAreaColour
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
EDTMSUP enableDTMSupport
EEDGE enableEdge
System Responses:
- Operation Completed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET TGTPTPPKF NAME=TGTBTS:0..1499/TGTPTPPKF:0..0 [,REQATTL=
RACODE ,RACOL ,GRXLAMI ,GMSTXPMAC ,EDTMSUP
,EEDGE];
NAME: name
RACOD
E:
routingAreaCode


A30808-X3247-M230-6-7619

1427
CML:BSC TGTPTPPKF
Id:0900d805800d4334
GET TGTPTPPKF BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TGTPTPPKF BASICS
None.
Example of Command Execution:
Get TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0,
REQATTL=RACODE&RACOL&GRXLAMI&GMSTXPMAC;
GET TGTPTPPKF BASICS
Get TGTPTPPKF BASICS:NAME=TGTBTS:0/TGTPTPPKF:0;
GET TGTPTPPKF BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF GET
TGTPTPPKF BASICS
RACOL: routingAreaColour
GRXLAMI: gprsLevAccessMin
GMSTXPMAC: gprsMsTxPwrMaxCch
NAME: name
RACOD
E:
routingAreaCode
RACOL: routingAreaColour
GRXLAMI: gprsLevAccessMin
GMSTXPMAC: gprsMsTxPwrMaxCch
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET TGTPTPPKF
BASICS
NAME=TGTBTS:0..1499/TGTPTPPKF:0..0;


1428 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4334
TGTPTPPKF
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the
TGTPTPPKF object class.
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
RACOL routingAreaColour
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
EDTMSUP enableDTMSupport
EEDGE enableEdge
System Responses:
See GET TGTPTPPKF
Application Guidelines:
See GET TGTPTPPKF
Example of Command Execution:
See GET TGTPTPPKF
SET TGTPTPPKF
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTBTS TGTPTPPKF SET
TGTPTPPKF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the TGTPTPPKF object class.
Long Names:
NAME Addres of the managed object
RACODE routingAreaCode
SET TGTPTPPKF NAME=TGTBTS:0..1499/TGTPTPPKF:0..0 [,RACODE=]
[,RACOL=] [,GRXLAMI=] [,GMSTXPMAC=] [,EDTMSUP=]
[,EEDGE=];


A30808-X3247-M230-6-7619

1429
CML:BSC TGTPTPPKF
Id:0900d805800d4334
RACOL routingAreaColour
GRXLAMI gprsRxLevelAccessMin
GMSTXPMAC gprsMsTxPwrMaxCch
EDTMSUP enableDTMSupport
EEDGE enableEdge
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set TGTPTPPKF:NAME=TGTBTS:0/TGTPTPPKF:0,RACODE=22,RACOL=0, GRXL-
AMI=0,GMSTXPMAC=2;
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The relevant TGTBTS object instance must be already created.


1430 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4337
TGTTDD
TGTTDD
CREATE TGTTDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD CREATE TGTTDD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows to create a target TDD object.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
RNCID rncId
BNDWIDTDD bandwidthTdd
TDDARFCN tddArfcn
TDDCPAR tddCellParameter
TDDSYNCCAS tddSyncCase
TDDDIV tddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE TGTTDD NAME=TGTTDD:0..1499 ,CELLGLID= ,RNCID= ,BND-
WIDTDD= ,TDDARFCN= ,TDDCPAR= ,TDDSYNCCAS=
,TDDDIV= [,MSTXPMAXUMTS=];
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The frequencies must be included in the range: 9262..9638,
9662..9938, 10062..10113.
UNSUCCESSFUL_CELL_GLOB_ID


A30808-X3247-M230-6-7619

1431
CML:BSC TGTTDD
Id:0900d805800d4337
Application Guidelines:
Regarding the number of allowed TGTTDD instances the following rules are valid:
in case of MPCC V9 the sum: (number of TGTBTS) + (number of TGTTDD) +
(number of TGTFDD) must be <= 1500, and at most 1500 instances (0..1499) can
be created for all the three classes.
Example of Command Execution:
Create TGTTDD:NAME=TGTTDD:0,CELLGLID="123"-"45"-1-1, RNCID=40,BND-
WIDTDD=MCPS384, TDDARFCN=9665, TDDCPAR=4,
TDDSYNCCAS=SYNC2, TDDDIV=DIVERSITY, MSTXPMAXUMTS=9;
DELETE TGTTDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD DELETE TGTTDD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created instance of the TGTTDD object class.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
All the fields of CELLGLID attribute must be set.
Two TGTTDD objects cannot have equal pair RNCID - CELLGLID.
DELETE TGTTDD NAME=TGTTDD:0..1499;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
The TGTTDD object instance cannot be deleted if is referenced as the
target cell by any ADJC3G object instance.


1432 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4337
TGTTDD
Example of Command Execution:
Delete TGTTDD:NAME=TGTTDD:0;
GET TGTTDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD GET TGTTDD
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameter values of an instance of the TGTTDD
object class.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
RNCID rncId
BNDWIDTDD bandwidthTdd
TDDARFCN tddArfcn
TDDCPAR tddCellParameter
TDDSYNCCAS tddSyncCase
TDDDIV tddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
- Operation Completed
GET TGTTDD NAME=TGTTDD:0..1499 [,REQATTL= CELLGLID ,RNCID
,BNDWIDTDD ,TDDARFCN ,TDDCPAR ,TDDSYNCCAS
,TDDDIV ,MSTXPMAXUMTS];
NAME: name
CELLGLID: cellGlobalIdentity
RNCID: rncId
BNDWIDTDD: bandwidthTdd
TDDARFCN: tddArfcn
TDDCPAR: tddCellParameter
TDDSYNCCAS: tddSyncCase
TDDDIV: tddDiversity
MSTXPMAXUMTS:msTxPwrMaxUmts


A30808-X3247-M230-6-7619

1433
CML:BSC TGTTDD
Id:0900d805800d4337
GET TGTTDD BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TGTTDD BASICS
None.
Example of Command Execution:
Get TGTTDD:NAME=TGTTDD:0,REQATTL=CELLGLID&RNCID&BNDWIDTDD&
TDDARFCN&TDDCPAR&TDDSYNCCAS&TDDDIV&MSTXPMAXUMTS;
GET TGTTDD BASICS
Get TGTTDD BASICS:NAME=TGTTDD:0;
GET TGTTDD BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD GET TGTTDD BASICS
Applicability:
Phase 2.
Visibility level: 0.
NAME: name
CELLGLID: cellGlobalIdentity
RNCID: rncId
BNDWIDTDD: bandwidthTdd
TDDARFCN: tddArfcn
TDDCPAR: tddCellParameter
TDDSYNCCAS: tddSyncCase
TDDDIV: tddDiversity
MSTXPMAXUMTS:msTxPwrMaxUmts
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET TGTTDD BASICS NAME=TGTTDD:0..1499;


1434 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4337
TGTTDD
Command Description:
This command is used to retrieve the parameter values of an instance of the TGTTDD
object class.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
RNCID rncId
BNDWIDTDD bandwidthTdd
TDDARFCN tddArfcn
TDDCPAR tddCellParameter
TDDSYNCCAS tddSyncCase
TDDDIV tddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
See GET TGTTDD
Application Guidelines:
See GET TGTTDD
Example of Command Execution:
See GET TGTTDD
SET TGTTDD
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TGTTDD SET TGTTDD
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the specific parameters of the TGTTDD object class.
Long Names:
NAME Addres of the managed object
CELLGLID cellGlobalIdentity
RNCID rncId
BNDWIDTDD bandwidthTdd
SET TGTTDD NAME=TGTTDD:0..1499 [,CELLGLID=] [,RNCID=] [,BND-
WIDTDD=] [,TDDARFCN=] [,TDDCPAR=] [,TDDSYNC-
CAS=] [,TDDDIV=] [,MSTXPMAXUMTS=];


A30808-X3247-M230-6-7619

1435
CML:BSC TGTTDD
Id:0900d805800d4337
TDDARFCN tddArfcn
TDDCPAR tddCellParameter
TDDSYNCCAS tddSyncCase
TDDDIV tddDiversity
MSTXPMAXUMTS msTxPwrMaxUmts
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Set TGTTDD:NAME=TGTTDD:0,CELLGLID="123"-"45"-1-1, RNCID=40,BND-
WIDTDD=MCPS384, TDDARFCN=9665, TDDCPAR=4,
TDDSYNCCAS=SYNC2, TDDDIV=DIVERSITY,MSTXPMAXUMTS=49;
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order to
perform the command.
UNSUCCESSFUL_INVALID_ATTRIBUTES
A BTS cannot have two TDD ADJC3Gs with the same
(TDDARFCN, TDDCPAR) pair.
The frequencies must be included in the range: 9262..9638,
9662..9938, 10062..10113.
At least two digits must be set for MNC, three for MCC.
UNSUCCESSFUL_CELL_GLOB_ID
Two TGTTDD objects cannot have equal pair RNCID - CELLGLID.


1436 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d433a
TRACE
TRACE
The TRACE object represents the object that controls the trace collection for the
generation of the trace records.
CREATE TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE CREATE TRACE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command creates the object TRACE representing the system capability of perform-
ing the tracing of subscriber's activities when specific events occur within PLMN.
Long Names:
NAME Addres of the managed object
RECCRI recordCriteria
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Create TRACE:NAME=TRACE:0,RECCRI=NO_CRITERIA
DELETE TRACE
CREATE TRACE NAME=TRACE:0..0 [,RECCRI=];
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created
in order to perform the command.
DELETE TRACE NAME=TRACE:0..0;


A30808-X3247-M230-6-7619

1437
CML:BSC TRACE
Id:0900d805800d433a
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE DELETE TRACE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the object TRACE, previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete TRACE:NAME=TRACE:0;
GET TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GET TRACE
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the TRACE object.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a TRACE, the relative object instance
must be in LOCKED state.
GET TRACE NAME=TRACE:0..0 [,REQATTL= RECCRI];


1438 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d433a
TRACE
Long Names:
NAME Addres of the managed object
RECCRI recordCriteria
System Responses:
- Operation Completed
GET TRACE BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TRACE BASICS
None.
Example of Command Execution:
Get TRACE:NAME=TRACE:0
GET TRACE BASICS
Get TRACE BASICS:NAME=TRACE:0;
GET TRACE BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GET TRACE BASICS
Applicability:
Phase 2.
Visibility level: 0.
NAME: name
RECCRI: recordCriteria
NAME: name
RECCRI: recordCriteria
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GET TRACE BASICS NAME=TRACE:0..0;


A30808-X3247-M230-6-7619

1439
CML:BSC TRACE
Id:0900d805800d433a
Command Description:
This command is used to retrieve the parameters of the TRACE object.
Long Names:
NAME Addres of the managed object
RECCRI recordCriteria
System Responses:
See GET TRACE
Application Guidelines:
See GET TRACE
Example of Command Execution:
See GET TRACE
GET TRACE STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GET TRACE STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
TRACE object:
Administrative State (AST)
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
GET TRACE STAT NAME=TRACE:0..0;


1440 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d433a
TRACE
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get TRACE STAT:NAME=TRACE:0;
GETINFO TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE GETINFO TRACE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the whole set of information regarding the TRACE
instance active in the system. The given information are organized as follows:
1. Report complete information
2. TRACE control identifier and states: AST, OST, UST
3. TRACE measurement flag
4. Granularity of time for trace measurement set by operator
5. Granularity of time for trace measurement calculated by the system
6. Maximum size of IMSI file
7. Record criteria
8. For each active TRACE and last five terminated traces the following information are
given: TRACE reference, IMSI, current file size, TRACE type, start time and the list
of the files already uploaded.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO TRACE NAME=TRACE:0..0;


A30808-X3247-M230-6-7619

1441
CML:BSC TRACE
Id:0900d805800d433a
USAGE STATE: ACTIVE
TRACEMR: TRUE
TRACEMG: 20
REALTRG: 3
MAX IMSI FILE SIZE: 10 MBYTES
RECORD CRITERIA: NO CRITERIA
LIST OF ALL ACTIVE TRACES:
TRACE REF: 0
IMSI NR: 555014400000047
CURRENT FILE SIZE: 3 KBYTES
TRACE TYPE: 33
START TIME: 31-MAR-2000 16:43:59
TRACE REF: 1
IMSI NR: 555015600000047
CURRENT FILE SIZE: 2 KBYTES
TRACE TYPE: 33
START TIME: 31-MAR-2000 16:44:00
TRACE REF: 6
IMSI NR: 556032600000042
CURRENT FILE SIZE: 2 KBYTES
TRACE TYPE: 33
START TIME: 31-MAR-2000 16:45:00
LIST OF THE LAST 5 TERMINATED TRACES:
TRACE REF: 0
IMSI NR: 555014400000047
TRACE TYPE: 33
START TIME: 31-MAR-2000 16:43:59
STOP TIME: 31-MAR-2000 16:43:57
TRACE REF: 4
IMSI NR: 555015600000047
TRACE TYPE: 33


1442 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d433a
TRACE
START TIME: 31-MAR-2000 16:44:00
STOP TIME: 31-MAR-2000 16:50:00
END OF REPORT
- Operation Failed
GETINFO TRACE NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack TRACE:
name = TRACE:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo TRACE:NAME=TRACE:0;
LOCK TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE LOCK TRACE
Applicability:
Phase 2.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another Getinfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 Getinfo commands already in progress.
LOCK TRACE NAME=TRACE:0..0;


A30808-X3247-M230-6-7619

1443
CML:BSC TRACE
Id:0900d805800d433a
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
2. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock TRACE:NAME=TRACE:0;
SHUTDOWN TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE SHUTDOWN TRACE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SHUTDOWN TRACE NAME=TRACE:0..0;


1444 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d433a
TRACE
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5 minutes ---------->
LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed. The timer is set at 5 minutes fixed value.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown TRACE:NAME=TRACE:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)


A30808-X3247-M230-6-7619

1445
CML:BSC TRACE
Id:0900d805800d433a
UNLOCK TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE UNLOCK TRACE
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock TRACE:NAME=TRACE:0;
UPLALLIMSITR TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE UPLALLIMSITR TRACE
Applicability:
Phase 2.
UNLOCK TRACE NAME=TRACE:0..0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UPLALLIMSITR
TRACE
NAME=TRACE:0..0 ,DESTDIR= ,OVERWRITE=;


1446 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d433a
TRACE
Visibility level: 3.
Command Description:
This command allows to upload, from BSC disk to LMT disk, the information related to
the trace activities related to all cells.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
UPLALLIMSITR TRACE:NAME=TRACE:0,DESTDIR="C:\Siemens\Trace",
FILE="*.*",OVERWRITE=YES;
UPLIMSITR TRACE
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRACE UPLIMSITR TRACE
Applicability:
Phase 2.
Visibility level: 3.
DIRECTORY_NOT_FOUND
FILE_NOT_FOUND
UPLIMSITR TRACE NAME=TRACE:0..0 ,DESTDIR= ,OVERWRITE= ,TRAC-
EREF=;


A30808-X3247-M230-6-7619

1447
CML:BSC TRACE
Id:0900d805800d433a
Command Description:
This command allows to upload, from BSC disk to LMT disk, the information related to
the trace activities related the cell defined by means of the TRACEREF parameter.
Long Names:
NAME Addres of the managed object
DESTDIR DestinationDir
OVERWRITE Overwrite
TRACEREF traceReference
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If the scannerlogfile is uploaded with OVERWRITE parameter set at NO and the file
already exists on the LMT disk, the LMT renames the existing one to
"oldfilename_DayMonthYearHourMinute.Thesameextention" and stores the
uploaded one to the disk.
2. If the user aborts the upload command or the link (between LMT and BSC) falls
down, then it is no more possible to upload the same file: a new measure file will be
created until new log files will be produced inside BSC.
Example of Command Execution:
UPLIMSITR TRACE:NAME=TRACE:0,DESTDIR="C:\Trace",FILE="General",
OVERWRITE=NO,TRACEREF=22;
DIRECTORY_NOT_FOUND
FILE_NOT_FOUND


1448 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
TRAU
The TRAU (Transcoder and Rate Adapter Unit) object represents the transcoder con-
nected to a certain BSC. The transcoder receives from one side a 2 Mbit/s PCM line with
16 kbit/s channels (on the Asub interface) and from the other side four 2 Mbit/s PCM
lines with 64 kbit/s channels.
CREATE TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU CREATE TRAU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds a TRAU object to the BSS and specifies its dedicated 2 Mbit PCM
line.
Long Names:
NAME Addres of the managed object
PCMSN pcmsNumber
TSYNC tSync
EXPSWV expectedSwVersion
ALLCRIT allocationCriteria
SALUNAME salesUniqueName
TEI tei
ETFO enableTFO
VQEST voiceQualityEnhancementStatus
ALCST automaticLevelControlStatus
ALCTGTLEV automaticLevelControlTargetLevel
NOIREDST noiseReductionStatus
NOIREDA noiseReductionAmount
AECST acusticEchoControlActivationStatus
INTCTMST integratedCellularTelephoneModemStatus
BULKDCONF bulkDelayConfiguration
CREATE TRAU NAME=TRAU:0..47 ,PCMSN= [,TSYNC=] ,EXPSWV=
[,ALLCRIT=] [,SALUNAME=] ,TEI= [,ETFO=] [,VQEST=]
[,ALCST=] [,ALCTGTLEV=] [,NOIREDST=] [,NOIREDA=]
[,AECST=] [,INTCTMST=] [,BULKDCONF=];


A30808-X3247-M230-6-7619

1449
CML:BSC TRAU
Id:0900d805800d46a2
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
SUPERORDINATE_NOTEQUIPPED
Each TRAU is connected to BSC through a 2 Mbit PCMS
line. As a consequence, the relevant PCMS and the
relevant LPDLS (LAPD Link) managed object must be
already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The PCMSN indicates the pcms number connected to the
TRAU. The pcms must be the same on which the time slot
of the LPDLS has been previously allocated.
The timer TSYNC must be set longer than ALARMT2 (see
LICD object).
The attributes ALCST, NOIRDST, AECST cannot be set
at ENABLED if VQEST is set at DISABLED.
INCOMP_NESWLOAD_VS_MESSAGE
The EXPSWV assigned to the TRAU is not handled by the
SW version of BSC.
The attributes VQEST, INTCTMST must be set at
DISABLED value if the Expected SW version running on
the TRAU belongs to BR7.0 release.
INVALID_SVR
The attribute ALLCRIT cannot assume value
COMPATIBLE_WITH_CROSS_CONNECT in case of
PCM24 (see attribute PCMTYPE of BSC object).
A TRAU with BR6.0 SW Version cannot have a value dif-
ferent from "01" or "02" in the fourth digit of EXPSWV
attribute.
A TRAU with BR7.0 SW Version cannot have a value dif-
ferent from "03" in the fourth digit of EXPSWV attribute.
INVALID_SALES_UNIQUE_NAME
If the SALUNAME is different from NOT_DEFINED, it
must be different from SALUNAME of the other equipped
TRAUs.


1450 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
Application Guidelines:
1. After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service
2. ALC and fixed volume control (defined by VOLDL/UL attributes of TSLA) are
mutually exclusive and to avoid to the network operator the need for resetting the
TSLA attributes on enabling ALC:
with ALC enabled, TSLA vol control is not checked/considered to be the default
value
with ALC enabled TSLA vol updates (SET TSLA volxx) are stored but "ignored"
by DSP SW
after disabling ALC the last updated and stored TSLA vol control value is no
more ignored
Example of Command Execution:
Create TRAU:NAME=TRAU:0,PCMSN=3,TSYNC=100,
EXPSWV="01-00-01-01-04-04_95-03-01",
ALLCRIT=NOT_COMPATIBLE_WITH_CROSSCONNECT,
SALUNAME="AD042S7449F",TEI=2,ETFO=FALSE, VQEST=ENABLED,
ALCST=EDDLONLY, ALCTGTLEV=m19dBM0, NOIREDST=ENABLED, NOIREDA=-
9, AECST=ENABLED, BULKDCONF=DELAY_200_ms, INTCTMST=ENABLED;
DELETE TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU DELETE TRAU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a TRAU object in the BSS, previously created.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
DELETE TRAU NAME=TRAU:0..47;
DELETE NACK:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED


A30808-X3247-M230-6-7619

1451
CML:BSC TRAU
Id:0900d805800d46a2
Application Guidelines:
No clock sychronization signal (SYNC) has to be derived from the PCMS line connected
to TRAU.
Example of Command Execution:
Delete TRAU:NAME=TRAU:5;
GET TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the TRAU object.
Long Names:
NAME Addres of the managed object
PCMSN pcmsNumber
TSYNC tSync
EXPSWV expectedSwVersion
ALLCRIT allocationCriteria
SALUNAME salesUniqueName
TEI tei
ETFO enableTFO
TOPOREL topologicalRelationship
VQEST voiceQualityEnhancementStatus
The object instance must be already equipped.
SUBORDINATE_EQUIPPED
No 2 Mbit PCM line on "A" interface has to be connected to
TRAU.
UNSUCCESSFUL_INVALID_STATUS
Before deleting a TRAU, the relative object instance must
be in LOCKED state.
GET TRAU NAME=TRAU:0..47 [,REQATTL= PCMSN ,TSYNC
,EXPSWV ,ALLCRIT ,SALUNAME ,TEI ,ETFO ,TOPOREL
,VQEST ,ALCST ,ALCTGTLEV ,NOIREDST ,NOIREDA
,AECST ,INTCTMST ,BULKDCONF];


1452 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
ALCST automaticLevelControlStatus
ALCTGTLEV automaticLevelControlTargetLevel
NOIREDST noiseReductionStatus
NOIREDA noiseReductionAmount
AECST acusticEchoControlActivationStatus
INTCTMST integratedCellularTelephoneModemStatus
BULKDCONF bulkDelayConfiguration
System Responses:
- Operation Completed
GET TRAU BASICS
NAME: name
PCMSN: pcmsn
TSYNC: tSync
EXPSWV: expectedSwVersion
ALLCRIT: tallocationCriteria
SALUNAME: salesUniqueName
TEI: tei
ETFO: enableTFO
TOPOREL: topologicalRelationship
VQEST: voiceQualityEnhancementStatus
ALCST: automaticLevelControlStatus
ALCTGTLEV: automaticLevelControlTargetLevel
NOIREDST: noiseReductionStatus
NOIREDA: noiseReductionAmount
AECST: acusticEchoControlActivationStatus
BULKD-
CONF:
bulkDelayConfiguration
INTCTMST: integratedCellularTelephoneModemStatus
NAME: name
PCMSN: pcmsn
TSYNC: tSync
EXPSWV: expectedSwVersion
ALLCRIT: tallocationCriteria
SALUNAME: salesUniqueName
TEI: tei


A30808-X3247-M230-6-7619

1453
CML:BSC TRAU
Id:0900d805800d46a2
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TRAU BASICS
None.
GET TRAU TIMER
None.
Example of Command Execution:
Get TRAU:NAME=TRAU:0,REQATTL=PCMSN&TSYNC&EXPSWV&
ALLCRIT&SALUNAME&TEI&ETFO&TOPOREL&VQEST&ALCST&ALCT-
GTLEV&NOIREDST&NOIREDA&AECST&BULKDCONF&INTCTMST;
GET TRAU BASICS
Get TRAU BASICS:NAME=TRAU:0;
GET TRAU TIMER
Get TRAU TIMER:NAME=TRAU:0;
ETFO: enableTFO
TOPOREL: topologicalRelationship
VQEST: voiceQualityEnhancementStatus
ALCST: automaticLevelControlStatus
ALCTGTLEV: automaticLevelControlTargetLevel
NOIREDST: noiseReductionStatus
NOIREDA: noiseReductionAmount
AECST: acusticEchoControlActivationStatus
BULKD-
CONF:
bulkDelayConfiguration
INTCTMST: integratedCellularTelephoneModemStatus
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1454 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
GET TRAU BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the TRAU object.
Long Names:
NAME Addres of the managed object
PCMSN pcmsNumber
EXPSWV expectedSwVersion
ALLCRIT allocationCriteria
SALUNAME salesUniqueName
TEI tei
ETFO enableTFO
TOPOREL topologicalRelationship
VQEST voiceQualityEnhancementStatus
ALCST automaticLevelControlStatus
ALCTGTLEV automaticLevelControlTargetLevel
NOIREDST noiseReductionStatus
NOIREDA noiseReductionAmount
AECST acusticEchoControlActivationStatus
INTCTMST integratedCellularTelephoneModemStatus
BULKDCONF bulkDelayConfiguration
System Responses:
See GET TRAU
Application Guidelines:
See GET TRAU
Example of Command Execution:
See GET TRAU
GET TRAU BASICS NAME=TRAU:0..47;


A30808-X3247-M230-6-7619

1455
CML:BSC TRAU
Id:0900d805800d46a2
GET TRAU TIMER
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU TIMER
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the TRAU object.
Long Names:
NAME Addres of the managed object
TSYNC tSync
System Responses:
See GET TRAU
Application Guidelines:
See GET TRAU
Example of Command Execution:
See GET TRAU
GET TRAU STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GET TRAU STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
TRAU object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Alarm Status (ALS)
Availability Status (AVS)
GET TRAU TIMER NAME=TRAU:0..47;
GET TRAU STAT NAME=TRAU:0..47;


1456 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get TRAU STAT:NAME=TRAU:0;
GETINFO TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GETINFO TRAU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The report complete indicator
2. The "OSU running" object and the "OSU version".
3. The TRAU name.
4. A "transcoder matrix" for each of the TRAU pcms timeslots: the number of subslots,
the PCMA number and the TSLA number.
5. The allocation criteria used.
6. TRAU states and statuses.
7. The number of traffic channels which are really transcoded.
8. The TSYNC time.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
GETINFO TRAU NAME=TRAU:0..47;


A30808-X3247-M230-6-7619

1457
CML:BSC TRAU
Id:0900d805800d46a2
9. Synchronization source; values: BSC or MSC.
10. The synchronization line (that is the PCMT line), but only if the SYNC source is MSC.
11. The configured transparent channels (SS7L, X25A).
12. The PCMA lines connected with the TRAU.
13. For each equipment object of TRAU the states and statuses: AST, OST,
STNDBYST.
14. The CTM flag, showing if a Cellular Text telephone Modem feature is enabled or not.
15. The VQE flag, showing if operator has enabled or not a Voice Quality Enhancement
feature.
16. For each TRAC:
VQE and CTM flags showing if the TRAC supports them;
17. A transcoder matrix for each of the TRAU pcms timeslots: the number of subslots,
the PCMA number and the TSLA number.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO TRAU ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT:
NAME = TRAU:0
REPORT COMPLETE: TRUE
OSU: TRAUOSUSW 0
ESU RUNNING VERSION: 02-06-01-01-00-00_00-01-10
SALES UNIQUE NAME: VOGHERA
ALLOCATION CRITERIA: < 0 -> NOT_COMPATIBLE_WITH_CROSSCONNECT,
1 -> COMPATIBLE_WITH_CORSSCONNECT >
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
USAGE STATE: IDLE
AVAILABILITY STATUS: NONE
PROCEDURAL STATUS: NONE
NR. OF TRANSCODED CHANNELS: 27
TSYNC: 0200
SYNC SOURCE: MSC


1458 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
SYNC LINE: 0
SS7L TIMESLOT: 2 - 4 21 - 30 (PCM NR - TS NR)
X25A TIMESLOT: 10 - 5 (PCM NR - TS NR)
PCMA CONNECTED: 2 10 21
OBJECT ADMINISTRATIVE OPERATIONAL STANDBY
TPWR 0 UNLOCKED DISABLED NONE
TPWR 1 UNLOCKED ENABLED NONE
BSMS 0 UNLOCKED ENABLED HOT_STANDBY
BSMS 1 UNLOCKED ENABLED PROVIDING_SERVICE
TRAC 0 UNLOCKED ENABLED COLD_STANDBY
TRAC 1 UNLOCKED ENABLED PROVIDING_SERVICE
...;...;...;
TRAC 5 UNLOCKED DISABLED NONE
CTM CONFIG: FALSE
VQE CONFIG: TRUE
OBJECT VQE SUPPORTED CTM SUPPORTED
TRAC 1 ENABLED NOT_APPLICABLE
TRAC 5 DISABLED NOT_APPLICABLE
TRAC n ENABLED NOT_APPLICABLE
TSLS NR. TSLSUB NR PCMA NR TSLA NR
1 0
1 1 1 1
1 2
1 3
2 0
2 1
2 2
2 3
3 0
3 1
3 2
3 3
4 0
4 1 1 4


A30808-X3247-M230-6-7619

1459
CML:BSC TRAU
Id:0900d805800d46a2
4 2
4 3
5 0
5 1
5 2
5 3
6 0
6 1 1 6
6 2
6 3
7 0
7 1
7 2
7 3
8 0
8 1 1 8
8 2
8 3
9 0
9 1
9 2
9 3
10 0
10 1
10 2
10 3
11 0
11 1 1 11
11 2
11 3
12 0
12 1 1 12
12 2
12 3
13 0
13 1 1 13
13 2
13 3
14 0


1460 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
14 1 1 14
14 2
14 3
15 0
15 1
15 2
15 3
16 0
16 1 1 16
16 2
16 3
17 0
17 1 1 17
17 2
17 3
18 0
18 1 1 18
18 2
18 3
19 0
19 1 1 19
19 2
19 3
20 0
20 1
20 2
20 3
21 0
21 1 1 21
21 2
21 3
22 0
22 1 1 22
22 2
22 3
23 0
23 1 1 23
23 2
23 3


A30808-X3247-M230-6-7619

1461
CML:BSC TRAU
Id:0900d805800d46a2
24 0
24 1 1 24
24 2
24 3
25 0
25 1 1 25
25 2
25 3
26 0
26 1 1 26
26 2
26 3
27 0
27 1 1 27
27 2
27 3
28 0
28 1 1 28
28 2
28 3
29 0
29 1 1 29
29 2
29 3
30 0
30 1
30 2
30 3
31 0
31 1
31 2
31 3
END OF REPORT
- Operation Failed


1462 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
NACK CAUSES:
Application Guidelines:
1. The sequence of the HW objects will not necessarily be in an alphabetical order and
only the equipped instances will be reported.
2. TSYNC is an attribute of the TRAU object (see TRAU object).
Example of Command Execution:
Getinfo TRAU:NAME=TRAU:0;
GETRELATIONSHIP TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GETRELATIONSHIP TRAU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the TRAU object the related HMOs are the following: LICD/LICDS, EPWR, BSMS,
TPWR, PPLD, PWRD, MPCC, TDPC, MEMT, NTW and PPXL.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another GetInfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 GetInfo commands already in progress.
GETRELATIONSHIP
TRAU
NAME=TRAU:0..47;


A30808-X3247-M230-6-7619

1463
CML:BSC TRAU
Id:0900d805800d46a2
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship TRAU:NAME=TRAU:0;
GETSUBO TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU GETSUBO TRAU
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO TRAU NAME=TRAU:0..47;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1464 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
Example of Command Execution:
Getsubo TRAU:NAME=TRAU:0;
LOCK TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU LOCK TRAU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
4. Before entering this command it is necessary to lock the Asub.
Example of Command Execution:
Lock TRAU:NAME=TRAU:0;
LOCK TRAU NAME=TRAU:0..47;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1465
CML:BSC TRAU
Id:0900d805800d46a2
SET TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU SET TRAU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the attributes of the TRAU object.
Long Names:
NAME Addres of the managed object
TSYNC tSync
EXPSWV expectedSwVersion
SALUNAME salesUniqueName
ETFO enableTFO
VQEST voiceQualityEnhancementStatus
ALCST automaticLevelControlStatus
ALCTGTLEV automaticLevelControlTargetLevel
NOIREDST noiseReductionStatus
NOIREDA noiseReductionAmount
AECST acusticEchoControlActivationStatus
INTCTMST integratedCellularTelephoneModemStatus
BULKDCONF bulkDelayConfiguration
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
SET TRAU NAME=TRAU:0..47 [,TSYNC=] [,EXPSWV=] [,SALU-
NAME=] [,ETFO=] [,VQEST=] [,ALCST=] [,ALCTGTLEV=]
[,NOIREDST=] [,NOIREDA=] [,AECST=] [,INTCTMST=]
[,BULKDCONF=];
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
INCOMP_NESWLOAD_VS_MESSAGE
The EXPSWV assigned to the TRAU is not handled by the SW
version of BSC.


1466 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
Application Guidelines:
1. TSYNC should be equal with TSYNC of the BTS object.
2. The timer TSYNC must be set longer than ALARMT2 (see LICD object).
3. ALC and fixed volume control (defined by VOLDL/UL attributes of TSLA) are
mutually exclusive and to avoid to the network operator the need for resetting the
TSLA attributes on enabling ALC:
with ALC enabled, TSLA vol control is not checked/considered to be the default
value
with ALC enabled TSLA vol updates (SET TSLA volxx) are stored but "ignored"
by DSP SW
after disabling ALC the last updated and stored TSLA vol control value is no
more ignored
Example of Command Execution:
Set TRAU:NAME=TRAU:0,TSYNC=10,EXPSWV="01-00-01-01-04-04_95-03-01",
The attributes VQEST, INTCTMST must be set at DISABLED
value if the Expected SW version running on the TRAU
belongs to BR7.0 release.
INVALID_SALES_UNIQUE_NAME
If the SALUNAME is different from NOT_DEFINED, it must be
different from SALUNAME of the other equipped TRAUs.
UNSUCCESSFUL_INVALID_STATUS
In order to set the ETFO (Enable TFO) parameter, the related
TRAU must be in the administrative state LOCKED.
TRAU SW Version cannot be changed by means of the
EXPSWV attribute if the TRAU object instance is not in the
administrative state LOCKED.
In order to set VQEST, ALCST, ALCTGTLEV, NOIREDST,
NOIREDA, AECST, BULKDCONF, INTCTMST parameters,
the related TRAU must be in the administrative state LOCKED.
INVALID_SVR
A TRAU with BR6.0 SW Version cannot have a value different
from "01" or "02" in the fourth digit of EXPSWV attribute.
A TRAU with BR7.0 SW Version cannot have a value different
from "03" in the fourth digit of EXPSWV attribute.
UNSUCCESSFUL_INVALID_TIME_SLOT
16 Kbit LPDLS are supported by TRAU with SW >= BR8.0 and
with Load >= 12.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The attributes ALCST, NOIRDST, AECST cannot be set at
ENABLED if VQEST is set at DISABLED.


A30808-X3247-M230-6-7619

1467
CML:BSC TRAU
Id:0900d805800d46a2
SALUNAME="AD042S7449F", VQEST=ENABLED, ALCST=EDDLONLY, ALCT-
GTLEV=ITU, NOIREDST=ENABLED, NOIREDA=-15, AECST=ENABLED, BULKD-
CONF=AUTOMATIC_LINK_DETECTION, INTCTMST=DISABLED;
SHUTDOWN TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU SHUTDOWN TRAU
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The system attempts to perform the command every 10 seconds for the next 6 minutes.
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
SHUTDOWN TRAU NAME=TRAU:0..47;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1468 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46a2
TRAU
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 6 minutes and 10
seconds ----------> LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown TRAU:NAME=TRAU:1;
UNLOCK TRAU
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU UNLOCK TRAU
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)
UNLOCK TRAU NAME=TRAU:0..47;


A30808-X3247-M230-6-7619

1469
CML:BSC TRAU
Id:0900d805800d46a2
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock TRAU:NAME=TRAU:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1470 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4340
TRAUOSUSW
TRAUOSUSW
The TRAUOSUSW (TRAU Operating Software Unit SW) is used to represent the
operating software resource for TRAU; the OSU objects are used to identify which ESUs
(Executable Software Unit) are operational.
GET TRAUOSUSW
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW GET TRAU-
OSUSW
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
PH phase
System Responses:
- Operation Completed
GET TRAUOSUSW BASICS
GET TRAUOSUSW NAME=TRAU:0..47/TRAUOSUSW:0..0 [,REQATTL=
RUNESU ,BCKUPESU ,PH];
NAME: name
RUNESU: runningESU
BCKUPESU: backupESU
PH: phase
NAME: name
RUNESU: runningESU
BCKUPESU: backupESU
PH: phase


A30808-X3247-M230-6-7619

1471
CML:BSC TRAUOSUSW
Id:0900d805800d4340
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TRAUOSUSW BASICS
None.
Example of Command Execution:
Get TRAUOSUSW:NAME=TRAU:0/TRAUOSUSW:0,REQATTL=RUNESU& BCK-
UPESU&PH;
GET TRAUOSUSW BASICS
Get TRAUOSUSW BASICS:NAME=TRAU:0/TRAUOSUSW:0;
GET TRAUOSUSW BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW GET TRAU-
OSUSW BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the values of the parameters selected by the operator
by means of the REQATTL correspondent list.
NO_ADMITTED_OPERATION
Waiting for SDSM server activation.
NO_TASKS_AVAILABLE
No free servers to perform the command.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
OBJECT_NOT_FOUND
The referenced object instance does not exist.
ABORT_BY_SYSTEM_NCK
This command is rejected due to an internal subsystem abort.
GET TRAUOSUSW
BASICS
NAME=TRAU:0..47/TRAUOSUSW:0..0;


1472 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4340
TRAUOSUSW
Long Names:
NAME Addres of the managed object
RUNESU runningESU
BCKUPESU backupESU
PH phase
System Responses:
See GET TRAUOSUSW
Application Guidelines:
See GET TRAUOSUSW
Example of Command Execution:
See GET TRAUOSUSW
GETINFO TRAUOSUSW
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW GETINFO
TRAUOSUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information about the "running" and the
"backup" SW version (all together) for a TRAU network element.
The information recovered are:
1. For each NEYESUSW corresponding to 'runningESU' attribute:
NEYESUSW instance identifier,
User label associated,
Version number,
Operational state;
2. For each NEYESUSW corresponding to 'backupESU' attribute:
NEYESUSW instance identifier,
User label associated,
Version number,
Operational state;
3. Information about the load usage state.
GETINFO TRAUO-
SUSW
NAME=TRAU:0..47/TRAUOSUSW:0..0;


A30808-X3247-M230-6-7619

1473
CML:BSC TRAUOSUSW
Id:0900d805800d4340
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO TRAUOSUSW ACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** INFORMATION ***
GETINFO REPORT TRAUOSUSW:
NAME = TRAUOSUSW:1
RUNNING ESU INSTANCE: 0
USER LABEL: 62TRAUAS0024
VERSION: 02-06-02-01-00-24_01-12-19
OPERATIONAL STATE: DISABLED
BACKUP ESU INSTANCE: 0
USER LABEL: 62BSCHB010024
VERSION: 02-06-02-01-00-24_01-12-19
OPERATIONAL STATE: ENABLED
LOAD USAGE STATE: IDLE
END OF REPORT
- Operation Failed
GETINFO TRAUOSUSW NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:21:29 22/09/1998
*** RESPONSE TO JOB 1 ***
Get Info Report Nack TRAUOSUSW:
name = TRAUOSUSW:1
nackCause = <nack cause>
NACK CAUSES:
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.


1474 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4340
TRAUOSUSW
Application Guidelines:
None.
Example of Command Execution:
Getinfo TRAUOSUSW:NAME=TRAU:0/TRAUOSUSW:1;
SETRUNBACK TRAUOSUSW
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL TRAU TRAUOSUSW SETRUN-
BACK TRAUOSUSW
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the user to perform a "run-back" procedure: load of the
TRAUOSUSW object from OSUSW backupESU object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another GetInfo on the input object is already in progress.
T_RESOURCE_NOT_AVAILABLE
If there are 10 GetInfo commands already in progress.
SETRUNBACK TRAU-
OSUSW
NAME=TRAU:0..47/TRAUOSUSW:0..0;
ABORT_BY_SYSTEM_NCK
An internal system abort is occurred.
OBJECT_NOT_FOUND
The referenced object instance does not exist.


A30808-X3247-M230-6-7619

1475
CML:BSC TRAUOSUSW
Id:0900d805800d4340
Application Guidelines:
The OperationalState attribute of the specific TRAUESUSW must be ENABLED. If the
precondition is not satisfied and/or if the dbVersion required is not stored on BSC disk,
then a specific error collector call is performed.
Example of Command Execution:
Setrunback TRAUOSUSW:NAME=TRAU:0/TRAUOSUSW:0;
INVALID_PARAMETER_NCK
The involved NE attribute does not exist.
The input parameter is out of range.
OBJECT_ALREADY_IN_USE
The command clashes with another one already in progress.
INCONSISTENT_STATE_NCK
NE activation time-out is expired.
INITIALIZATION_IN_PROGRESS_NCK
An initialization of the system is in progress.
UNSUCCESSFUL_SYS_CALL
A system function call is failed.
UNSUCCESSFUL_OBJ_NOTEQUIPPED
NE is not equipped.
EXPECTED_SWVER_UNDEFINED_NCK
Expected SW version is not defined for NE.
PROCESSING_ERROR_NCK
A function call (for example allocation of memory) fails.
UNSUCCESSFUL_LINK_NOT_AVAIL
The link with NE is not activated.
DOWNLOAD_ALREADY_IN_PROGRESS_NCK
A download of the same NE is already in progress.


1476 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
TRX
The TRX (Transceiver) object locates the transceivers connected to a certain BSC.
CREATE TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX CREATE TRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command defines the global parameters of the Transceiver (TRX) for the TRX
dedicated to both traffic and BCCH functions.
Long Names:
NAME Addres of the managed object
TRXFREQ carrierFrequency
PWRRED txPwrMaxReduction
RADIOMR radioMeasRep
RADIOMG radioMeasGran
MOEC memberOfEmergencyConfig
TRXAREA trxArea
LPDLMN lapdmNumber
TRXMD trxMode
MAIO maio
FHSYID frequencyHoppingID
LAYERID layerIdentifier
USFGRAN uSFGranularity
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
CREATE TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23 ,TRXFREQ=
[,PWRRED=] [,RADIOMR=] [,RADIOMG=] [,MOEC=] [,TRX-
AREA=] ,LPDLMN= [,TRXMD=] [,MAIO=] [,FHSYID=] [,LAY-
ERID=] [,USFGRAN=];
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED


A30808-X3247-M230-6-7619

1477
CML:BSC TRX
Id:0900d805800d46ab
The CFHSY or FHSY must be already equipped if present
into FHSYID.
UNSUCCESSFUL_OBJECT_ALREADY_EQUIPPED
The instance of the TRX managed object must not be already
equipped.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
The maximum number of TRXs per BSS is 500.
UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL
The carrier frequency (TRXFREQ) of the TRX must belong to
the set of frequencies assigned to the cell.
UNSUCCESSFUL_FREQ_BELONG_TO_ANOTHER_TRX
The carrier frequency (TRXFREQ) of the TRX must not be
already assigned to another TRX belonging to the same BTS.
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The number of available carrier frequencies (set in the
CALLF<nn> parameters of the BTS object) has been already
reached.
UNSUCCESSFUL_INVALID_TRX_AREA
The attribute TRXAREA cannot be set at NONE value if the
CONCELL parameter (see BTS object) is set at TRUE.
The attribute TRXAREA cannot be set at INNER/COMPLETE
values if the CONCELL parameter (see BTS object) is set at
FALSE.
The attribute TRXAREA cannot be set at INNER value on the
TRX with broadcast functions.
In a GSM850DCS concentric cell, all the TRXs belonging to
the same band have to belong to the same area (inner or
complete).
The attribute TRXAREA cannot assume value different from
NONE in a Dual Band Standard Cell.
UNSUCCESSFUL_INVALID_STATUS
Before creating a TRX, the RFLOOP object instance relative
to the BTS which the TRX belongs to must be in the
administrative state LOCKED.
To assign the TRX to a layer presents into service list GLL-
PRM/GLLCOM or ELLPRM/ELLCOM, the PTPPKF subordi-
nate to BTS object must be locked.
UNSUCCESSFUL_LINK_NOT_AVAIL
In case of NTWCARD different from NTWSNAP, there are no
more TEIs available.
UNSUCCESSFUL_EXCEED_OBJECT_NBR


1478 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
If the BTSM is a BS-240XS, it is not possible to create for
each subordinate BTS a TRX number greater than 2.
If the BTSM is a BS-240XS, it is not possible to create for
each BTSM a TRX number greater than 6.
No more than 24 TRX per BTSM can be created if the SW of
the superordinate BTSM is less than BR8.0.
Only if the superordinate BTSM is a BTSPlus up to 48 TRX
per BTSM can be equipped starting from BR8.0.
UNSUCCESSFUL_INVALID_ATTRIBUTES
BCCH TRX must be assigned to LY0.
If FHSYID is equal to FHSY0 then MAIO is 0, NULL or
skipped.
Two TRXs that point to different hopping law (CFHSY and
FHSY) cannot have the same layer if DMA is enabled in the
cell.
A TRX that point to a CFHSY 0 cannot have the same layer
of a TRX that point to CFHSY 1 if DMA is enabled in the cell.
UNSUCCESSFUL_EDGE_NOT_SUPPORTED
The attribute TRXMD can not be set at EDGE if ESUP
attribute of BSC object is set at FALSE.
UNSUCCESSFUL_EDGE_ENABLED
The attribute TRXMD can not be set at GSM if EEDGE
attribute of related PTPPKF object is set at TRUE and none
of remaining TRXs in the cell has TRXMD set at EDGE.
In order to set the flag EEDGE to TRUE in PTPPKF object,
every layer assigned to the primary/complementary layer list
of EDGE service (ELLPRM/COM of BTS object) must
contain:
- at least one TRX with TRXMD=EDGE, if the layer is not
exclusive for EDGE
- all the TRXes with TRXMD=EDGE, if the layer is exclusive
for EDGE.
UNSUCCESSFUL_EDGE_ON_BCCH_AVAILABLE
The attribute TRXMD (of BCCH TRX) can not be set at GSM
if EBCCHTRX is set at TRUE.
INCOMP_NESWLOAD_VS_MESSAGE
The attribute TRXMD can not be set at EDGE if the
SW Version running on the superordinated BTSM object
belongs to BR6.0 release (see EXPSWV parameter
description).
The attribute TRXMD can not be set at EDGE if the BTSE is
not a BTS+.


A30808-X3247-M230-6-7619

1479
CML:BSC TRX
Id:0900d805800d46ab
Application Guidelines:
1. If the transceiver carrier frequency corresponds to the frequency indicated by the
BCCHFREQ parameter (previously set at the creation of the BTS managed object),
then it is assumed that the transceiver is the broadcast one.
2. After the creation of the object the ADMINISTRATIVE state of this object is set at
LOCKED. An UNLOCK command is required to put this object in service.
3. For concentric cells, the PWRRED parameter of the TRXs belonging to the inner
area should be set at a value different from 0.
4. If only one 64 kbit/s LAPD channel is created in BSC and BTSE, the number of full
rate and half rate TRXs to be configured is limited and might be lower than the
maximum possible of 24 TRXs, in order not to increase the Call Failure Rate (the
expression 'half(full) rate TRXs' only means "how many TRXs would be covered if
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The LPDLM reference in the LPDLMN object must be already
equipped.
HOPPING_NOT_ALLOWED
It is not possible to set the FHSYID of a BCCH TRX at a value
different from FHSY0 or NULL.
HOPPING_ACTIVE
If hopping is active then a TRX can neither be created
hopping.
INVALID_MAIO
The value for MAIO must be less than the number of frequen-
cies in the mobile allocation of the FHSY or CFHSY instance
used.
OVERLAP_BAND
When the frequency band of the BTS is EXT900 the TRX can
use only the Frequency Hopping sequence in the same band
of the TRXFREQ.
The sub-band of CFHSY pointed must be compatible with
system indicator of TRX.
INVALID_HOPP_GROUP
In case of concentric cell and base band hopping selected,
the attribute FHSYID of a INNER TRX cannot be set with a
frequency hopping system that use frequencies of complete
area (and viceversa).
The TRX cannot to point to CFHSY with some frequencies
don't contain into superordinated BTS.
On a DMA layer the FHSYID cannot be NULL.


1480 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
the HR(FR) channels were on the same TRXs"; the intention is to have a practical
and not too detailed result).
The maximum allowed number of configured full rate and half rate TRXs can be
estimated according to the following rule:
2 * (number of half rate TRXs) + (number of full rate TRXs) <= 32.
This rule is valid only if no radio measurements are activated within a BTSM. If two
or more 64 kbit/s LAPD channels are created there is no limitation for the number of
configured TRXs.
5. Special care has to be applied if the RADIOMR attribute is set at ON for several
TRXs. For more details see Appendix B: Group 8.
Example of Command Execution:
Create TRX:NAME=BTSM:0/BTS:0/TRX:0,TRXFREQ=CALLF02,PWRRED=0,
RADIOMR=ON,RADIOMG=2,MOEC=TRUE,TRX-
AREA=NONE,LPDLMN=0,TRXMD=GSM,MAIO=<NULL>,FHSYID=<NULL>,LAY-
ERID=LY_00, USFGRAN=DISABLED;
DELETE TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX DELETE TRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes a previously created TRX.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
- Operation Failed
NACK CAUSES:
DELETE TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23;
Successful
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

1481
CML:BSC TRX
Id:0900d805800d46ab
Application Guidelines:
None.
Example of Command Execution:
Delete TRX:NAME=BTSM:0/BTS:0/TRX:0;
Before deleting a TRX, the relative object instance must be in
LOCKED state.
Before deleting a TRX, the RFLOOP object instance
configured in the cell which the TRX belongs to must be in
LOCKED state.
Before deleting a TRX, the SCA object instance configured in
the cell which the TRX belongs to must be in LOCKED state.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The SLL attributes cannot contain empty layers, i.e. layers
not assigned to any equipped TRX; in order to assign a layer
to a service at least one equipped TRX must have this layer
in LAYERID attribute.
In concentric cells, every layer assigned to the primary and
the complementary service layer lists for each service must
contain at least one TRX belonging to the related area.
In dual band standard cells, every layer assigned to the asci
service layer lists must contain at least one TRX with the fre-
quency belonging to the BCCH's band.
In dual band cells, the SLLPRM or SLLCOM must contain at
least one TRX per layer with the frequency belonging to the
related band.
UNSUCCESSFUL_EDGE_ENABLED
If the flag EEDGE is set at TRUE in PTPPKF object, every
layer assigned to the primary/complementary layer list of
EDGE service (ELLPRM/COM of BTS object) must contain:
- at least one TRX with TRXMD=EDGE, if the layer is not
exclusive for EDGE
- all the TRXes with TRXMD=EDGE, if the layer is exclusive
for EDGE.
UNSUCCESSFUL_DEL_ALL_CHAN_BEFORE
Before deleting a TRX object instance it is necessary to
delete all the channels belonging to the involved TRX.
UNSUCCESSFUL_HOPP_TRX
In case of base band frequency hopping, the TRX carrier fre-
quency must not be assigned to any FHSY instance.
INVALID_COMMAND
With ENDMA to TRUE (BTS object), the last TRX that points
to CFHSY cannot be deleted.


1482 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
GET TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GET TRX
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a previously created TRX.
Long Names:
NAME Addres of the managed object
TRXFREQ carrierFrequency
PWRRED txPwrMaxReduction
BCCHTRX bcchTransceiver
RADIOMR radioMeasRep
RADIOMG radioMeasGran
MOEC memberOfEmergencyConfig
TRXAREA trxArea
TEI tei
LPDLMN lapdmNumber
TRXFREQV carrierFrequencyValue
TRXMD trxMode
MAIO maio
FHSYID frequencyHoppingID
LAYERID layerIdentifier
USFGRAN uSFGranularity
System Responses:
- Operation Completed
GET TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23 [,REQATTL=
TRXFREQ ,PWRRED ,BCCHTRX ,RADIOMR ,RADIOMG
,MOEC ,TRXAREA ,TEI ,LPDLMN ,TRXFREQV ,TRXMD
,MAIO ,FHSYID ,LAYERID ,USFGRAN];
TRXFREQ: carrierFrequency
PWRRED: txPwrMaxReduction
RADIOMR: radioMeasRep
RADIOMG: radioMeasGran
MOEC: MemberOfEmergencyConfig


A30808-X3247-M230-6-7619

1483
CML:BSC TRX
Id:0900d805800d46ab
GET TRX BASICS
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GET TRX BASICS
None.
Example of Command Execution:
Get TRX:NAME=BTSM:0/BTS:0/TRX:0,REQATTL=TRXFREQ&PWRRED&RADI-
OMR&RADIOMG&MOEC&TRXAREA&LPDLMN&TRXMD&MAIO&FHSYID&LAY-
ERID&USFGRAN;
TRXAREA: trxArea
LPDLMN:lapdmNumber
TRXMD:trxMode
MAIO:maio
FHSYID:frequencyHoppingID
LAYERID:layerId
USFGRAN: uSFGranularity
TRXFREQ: carrierFrequency
PWRRED: txPwrMaxReduction
RADIOMR: radioMeasRep
RADIOMG: radioMeasGran
MOEC: MemberOfEmergencyConfig
TRXAREA: trxArea
LPDLMN:lapdmNumber
TRXMD:trxMode
MAIO:maio
FHSYID:frequencyHoppingID
LAYERID:layerId
USFGRAN: uSFGranularity
NOT_EQUIPPED
The object instance must be already equipped.


1484 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
GET TRX BASICS
Get TRX BASICS:NAME=BTSM:0/BTS:0/TRX:0;
GET TRX BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GET TRX
BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of a previously created TRX.
Long Names:
NAME Addres of the managed object
TRXFREQ carrierFrequency
PWRRED txPwrMaxReduction
BCCHTRX bcchTransceiver
RADIOMR radioMeasRep
RADIOMG radioMeasGran
MOEC memberOfEmergencyConfig
TRXAREA trxArea
TEI tei
LPDLMN lapdmNumber
TRXFREQV carrierFrequencyValue
TRXMD trxMode
MAIO maio
FHSYID frequencyHoppingID
LAYERID layerIdentifier
USFGRAN uSFGranularity
System Responses:
See GET TRX
Application Guidelines:
See GET TRX
Example of Command Execution:
See GET TRX
GET TRX BASICS NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


A30808-X3247-M230-6-7619

1485
CML:BSC TRX
Id:0900d805800d46ab
GET TRX STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GET TRX STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the TRX
object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Procedural Status (PRS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Get TRX STAT:NAME=BTSM:0/BTS:0/TRX:0;
GET TRX STAT NAME=BTSM:0..199/BTS:0..23/TRX:0..23;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1486 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
GETINFO TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GETINFO TRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the following information:
1. The report complete indication.
2. The states and statuses of the TRX: AST, OST, UST, AVS, PRS.
3. The TRX absolute number.
4. The TRX capability (UNKNOWN, GSM, EDGE).
5. The TRX mode (GSM, EDGE).
6. The number of the layer associated with the TRX.
7. The AntennaHopping Period used.
8. The Antenna Hw list.
9. For each channel of the TRX:
the type
the pool type
the usage mode
the states and statuses (AST, OST, UST, AVS)
the hopping law
the Mobile Allocation Index Offset used
service type
the list of connected SUBTSLBs
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
GETINFO TRX ACK:
BSC_CONTROLLER -> LMT_LOCAL
11:41:14 22/03/1999
*** INFORMATION ***
GET INFO REPORT TRX:
NAME = TRX:0
GETINFO TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


A30808-X3247-M230-6-7619

1487
CML:BSC TRX
Id:0900d805800d46ab
Layout TRX with static Maio allocation
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE UNLOCKED
OPERATIONAL STATE ENABLED
USAGE STATE IDLE
AVAILABILITY STATUS DEPENDENCY
PROCEDURAL STATUS NONE
TRX ABSOLUTE NR: 5
TRX CAPABILITY: GSM
TRX MODE: EDGE
LAYER: LY2
CONFIGURED ANTENNA HOPPING PERIOD: EVERY FOURTH FRAME
ANTENNAS LIST (max 23 instances):
DUVSWR 0-0 DUVSWR 0-1 DUVSWR 0-2
CHAN 0
TYPE TSC_DH
POOL TYPE SDCCH_POOL
USAGE MODE MODE_SDCCH
ADMINISTRATIVE UNLOCKED
USAGE IDLE
OPERATIONAL ENABLED
AVAILABILITY NONE
MAIO USED 62
HOPPING LAW CFHSY_0
SERVICE PACKED
CONNECTED ABIS 12-15-0 12-15-1 12-15-2 13-4-0
CHAN 1
TYPE FULL_AND_HALF
POOL TYPE NOT_DEFINED
USAGE MODE NOT_APPLICABLE
ADMINISTRATIVE UNLOCKED
OPERATIONAL ENABLED
USAGE BUSY
AVAILABILITY NONE


1488 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
HOPPING LAW FHSY_2
MAIO USED 6
SERVICE PACKED
CONNECTED ABIS 13-4
CHAN 7
TYPE FULL_AND_HALF
POOL TYPE NOT_DEFINED
USAGE MODE NOT_APPLICABLE
ADMINISTRATIVE UNLOCKED
OPERATIONAL ENABLED
USAGE IDLE
AVAILABILITY NONE
HOPPING LAW FHSY_3
MAIO USED 3
SERVICE NO_DEDICATED
CONNECTED ABIS 13-4
END OF REPORT
Layout TRX with dynamic Maio allocation
REPORT COMPLETE: TRUE
ADMINISTRATIVE STATE UNLOCKED
OPERATIONAL STATE ENABLED
USAGE STATE IDLE
AVAILABILITY STATUS DEPENDENCY
PROCEDURAL STATUS NONE
TRX ABSOLUTE NR: 5
TRX CAPABILITY: GSM
TRX MODE: EDGE
LAYER: LY2
GPRS SUPPORTED: TRUE
CONFIGURED ANTENNA HOPPING PERIOD: EVERY FOURTH FRAME
ANTENNAS LIST (max 23 instances):
DUVSWR 0-0 DUVSWR 0-1 DUVSWR 0-2


A30808-X3247-M230-6-7619

1489
CML:BSC TRX
Id:0900d805800d46ab
CHAN 0
TYPE TSC_DH
POOL TYPE SDCCH_POOL
USAGE MODE MODE_SDCCH
ADMINISTRATIVE UNLOCKED
OPERATIONAL ENABLED
USAGE IDLE
AVAILABILITY NONE
HOPPING LAW CFHSY_1
MAIO USED 62
SERVICE PACKED
CONNECTED ABIS 12-15-0 12-15-1 12-15-2 13-4-0
CHAN 1
TYPE FULL_AND_HALF
POOL TYPE NOT_DEFINED
USAGE MODE NOT_APPLICABLE
ADMINISTRATIVE UNLOCKED
OPERATIONAL ENABLED
USAGE BUSY
AVAILABILITY NONE
HOPPING LAW CFHSY_1
MAIO USED 60
SERVICE PACKED
CONNECTED ABIS 13-4
CHAN 7
TYPE FULL_AND_HALF
POOL TYPE NOT_DEFINED
USAGE MODE NOT_APPLICABLE
ADMINISTRATIVE UNLOCKED
OPERATIONAL ENABLED
USAGE IDLE
AVAILABILITY NONE
HOPPING LAW CFHSY_1
MAIO USED 13
SERVICE NO_DEDICATED
CONNECTED ABIS 13-4


1490 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
END OF REPORT
- Operation Failed
GETINFO TRX NACK:
BSC_CONTROLLER -> LMT_LOCAL
16:24:45 22/09/1998
*** RESPONSE TO JOB 1***
Get Info Report Nack TRX:
NAME = TRX:0
nackCause = <nack cause>
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getinfo TRX:NAME=BTSM:0/BTS:0/TRX:0;
GETRELATIONSHIP TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GETRELATION-
SHIP TRX
Applicability:
Phase 2.
Visibility level: 1.
UNSUCCESSFUL_WRONG_ME_ID
The object received in input is not handled by the subsystem.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
T_REQUEST_ALREADY_IN_PROGRESS
If another GetInfo on the input object is already running.
T_RESOURCE_NOT_AVAILABLE
If there are 10 GetInfo commands already in progress.
GETRELATIONSHIP
TRX
NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


A30808-X3247-M230-6-7619

1491
CML:BSC TRX
Id:0900d805800d46ab
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality.
For the TRX object the related HMOs are the following: EPWR, LICD, LICDS, PPLD,
PWRD, MPCC, TDPC, MEMT, NTW and all the BTSE HMOs that implement the TRX
functionality for a certain BTS.
For BS-2x/6x, the BTSE HMOs are: ACOM, BBSIG, CCLK, CCTRL, FTNF, FVSWR,
GPSU, LI, PA, RXMUCO, RXAMOD and TPU.
For BS-4x/240/241/240XL, the BTSE HMOs are: COBA, COSA, CU, DIDCTMA, DILNA,
DUDCTMA, DULNA, DUVSWR, FTNFP, FVSWRP and TMA.
For the BS-82, the BTSE HMOs are: COBA, CU, DUVSWR and DULNA.
In case of a switched beam cell the attribute relatedEquipObjects shall include the new
HMOs SDUSEC, SDUSUBSEC, SDUTXSW and SDULNA.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship TRX:NAME=BTSM:0/BTS:0/TRX:0;
GETSUBO TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX GETSUBO TRX
Applicability:
Phase 2.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
GETSUBO TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


1492 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo TRX:NAME=BTSM:0/BTS:0/TRX:0;
LOCK TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX LOCK TRX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


A30808-X3247-M230-6-7619

1493
CML:BSC TRX
Id:0900d805800d46ab
NACK CAUSES:
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
4. In case of lock of TRX: a substitute TRX of the same BTS is chosen according to
following conditions (if the 1st condition is not available, the following one is chosen):
TRX with only TCH;
TRX with TCHs & 1 SDCCH;
TRX with TCHs & 1 SCBCH;
TRX with BCCH, MBCCHC, BCBCH.
Example of Command Execution:
Lock TRX:NAME=BTSM:0/BTS:0/TRX:0;
SET TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX SET TRX
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command modifies the global parameters of the Transceiver (TRX) for the TRX
dedicated to both traffic and BCCH function.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23 [,TRXFREQ=]
[,PWRRED=] [,RADIOMR=] [,RADIOMG=] [,MOEC=] [,TRX-
AREA=] [,TRXMD=] [,MAIO=] [,FHSYID=] [,LAYERID=]
[,USFGRAN=];


1494 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
Long Names:
NAME Addres of the managed object
TRXFREQ carrierFrequency
PWRRED txPwrMaxReduction
RADIOMR radioMeasRep
RADIOMG radioMeasGran
MOEC memberOfEmergencyConfig
TRXAREA trxArea
TRXMD trxMode
MAIO maio
FHSYID frequencyHoppingID
LAYERID layerIdentifier
USFGRAN uSFGranularity
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_SUPERORDINATE_NOTEQUIPPED
The CFHSY or FHSY must be already equipped if present into
FHSYID.
UNSUCCESSFUL_SUBORDINATE_EQUIPPED
If the BCCH TRX contains GPRS control channels (PBCCH,
PCCCH), its Layer (LY0) must be assigned at least to GPRS
service in case of TRXMD=GSM, at least to EDGE in case of
TRXMD=EDGE, or to both services.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_FREQUENCY_NOT_BELONG_TO_CEL
The carrier frequency (TRXFREQ) of the TRX must belong to
the set of frequencies assigned to the cell.
UNSUCCESSFUL_FREQ_BELONG_TO_ANOTHER_TRX
The carrier frequency (TRXFREQ) of the TRX must not be
already assigned to another TRX belonging to the same BTS.
UNSUCCESSFUL_INVALID_BCCH_FREQUENCY
If the TRX is the broadcast one, then its carrier frequency must
be equal to the frequency that has been configured as
BCCHFREQ in the BTS (see BTS object).
UNSUCCESSFUL_INVALID_STATUS


A30808-X3247-M230-6-7619

1495
CML:BSC TRX
Id:0900d805800d46ab
Make reference to APPLICATION GUIDELINES n. 1, n. 4, n. 11.
The FHSYID attribute can be modified from FHSY0 to "different
from FHSY0 value" only if the subordinate channels are locked.
The FHSYID attribute can be modified from "different from
FHSY0 value" to "different from FHSY0 value" only if the two fre-
quency hopping systems have the same HSN, otherwise the
subordinate channels must be put in locked state.
To assign the TRX to a layer presents into service list GLL-
PRM/GLLCOM or ELLPRM/ELLCOM, the PTPPKF subordi-
nated to BTS object must be locked.
The attribute USFGRAN cannot be changed if the TRX is not in
LOCKED state.
UNSUCCESSFUL_VAR_OUT_OF_RANGE
In case of EXT900 frequency band, if the TRX has some
signalling channels subordinated then the carrier frequency
must be in the range 1..124.
UNSUCCESSFUL_HOPP_TRX
In case of base band frequency hopping, the old carrier fre-
quency cannot be assigned to a FHSY instance.
UNSUCCESSFUL_INVALID_TRX_AREA
Make reference to APPLICATION GUIDELINES n. 2, n. 3, n. 5,
n. 6, n. 7, n. 9.
The attribute TRXAREA cannot assume value different from
NONE in a Dual Band Standard Cell.
FREQUENCY_NOT_ALLOWED
In case of synthesizer frequency hopping, the new
carrierFrequency cannot be already used by any equipped fre-
quency hopping systems.
GPRS_TSC_INCONSISTENT


1496 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
If the EGPRS flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in GLLPRM/GLLCOM, single TCHs on
timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to
the layers contained in GLLPRM/GLLCOM all single TCHs must
have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
If the DTMSUP flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet
Services in Primary area, single TCHs on timeslot from 1 to 7
must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to
the layers shared between Signalling, Circuit and Packet
Services in Primary area all single TCHs must have the same
TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
GPRS_HOPP_INCONSISTENT
If the EGPRS flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in GLLPRM/GLLCOM, single TCHs on
timeslot from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in GLLPRM/GLLCOM, different from the
BCCH one, all single TCHs must have the same FHSYD and
MAIO.
UNSUCCESSFUL_INVALID_ATTRIBUTES
If at least one subordinate channel doesn't exist, the MAIO must
be 0, NULL or skipped if FHSYID is set to FHSY0. If subordinate
channels exist the relationship FHSYID MAIO must be fulfilled:
FHSYID (TRX or CHAN object) = FHSY0, MAIO (TRX or CHAN
object)=0
FHSYID (TRX or CHAN object) > FHSY0, MAIO (TRX or CHAN
object)=0-63


A30808-X3247-M230-6-7619

1497
CML:BSC TRX
Id:0900d805800d46ab
Two TRXs that point to different hopping law (CFHSY and
FHSY) cannot have the same layer, if the DMA is enabled in the
cell.
To change the layer associated to TRX from DMA to SMA and
viceversa, the DMA must be disabled in the site, if there are
some hopping channels on TRX.
BCCH TRX must be assigned to LY0.
In concentric cells, every layer assigned to the primary and the
complementary service layer lists for each service must contain
at least one TRX belonging to the related area.
TRXs containing signalling channels(including TCHSD
channels with TCHSD or SDCCH pool) must belong to layers
assigned to the signalling service.
The SLL attributes cannot contain empty layers, i.e. layers not
assigned to any equipped TRX; in order to assign a layer to a
service at least one equipped TRX must have this layer in
LAYERID attribute.
In dual band standard cells, every layer assigned to the asci
service layer lists must contain at least one TRX per layer with
the frequency belonging to the band of BCCH.
A TRX that point to a CFHSY 0 cannot have the same layer of
a TRX that point to CFHSY 1 if DMA is enabled in the cell.
In dual band cells, the SLLPRM or SLLCOM must contain at
least one TRX per layer with the frequency belonging to the
related band.
UNSUCCESSFUL_EDGE_NOT_SUPPORTED
The attribute TRXMD can not be set at EDGE if ESUP attribute
of BSC object is set at FALSE.
UNSUCCESSFUL_EDGE_ENABLED
If the flag EEDGE is set at TRUE in PTPPKF object, every layer
assigned to the primary/complementary layer list of EDGE
service (ELLPRM/COM of BTS object) must contain:
- at least one TRX with TRXMD=EDGE, if the layer is not exclu-
sive for EDGE
- all the TRXes with TRXMD=EDGE, if the layer is exclusive for
EDGE.
UNSUCCESSFUL_EDGE_ON_BCCH_AVAILABLE
The attribute TRXMD (of BCCH TRX) can not be set at GSM if
EBCCHTRX is set at TRUE.
INCOMP_NESWLOAD_VS_MESSAGE


1498 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
The attribute TRXMD can not be set at EDGE if the
SW Version running on the superordinated BTSM object
belongs to BR6.0 release (see EXPSWV parameter descrip-
tion).
The attribute TRXMD can not be set at EDGE if the BTSE is not
a BTS+.
UNSUCCESSFUL_HOPPING_SYSTEM_INCONSISTENT
The attribute TRXMD can not be set at GSM or EDGE if the TRX
belongs to a hopping law.
HOPPING_NOT_ALLOWED
It is not possible to set the FHSYID of a BCCH TRX at a value
different from FHSY0 or NULL.
HOPPING_ACTIVE
If at least one channel is equipped; the attribute FHSYID and
MAIO can be modified only if the Frequency Hopping is disabled
(ENHOPP parameter of the BTS object must be FALSE).
UNSUCCESSFUL_NO_MORE_FREQ_AVAILABLE
The number of channels with the same time slot number,
pointing to the same FHSY or CFHSY instance cannot be
greater than number of frequencies in the mobile allocation of
the frequency hopping law.
INVALID_HOPP_GROUP
In case of concentric cell and base band hopping selected, the
attribute FHSYID of a INNER TRX cannot be set with a fre-
quency hopping system that use frequencies of complete area
(and viceversa).
The channel cannot to point to CFHSY with some frequencies
don't contain into superordinated BTS.
To set FHSYID to a value different by NULL, all subordinate
channels must have the same value of FHSYID.
TRXs having subordinate channels with the same time slot
number, cannot point to different FHSY instance if the two
FHSY instance use the same frequencies.
It is not possible to have 2 TRXs, with subordinate channels with
the same time slot number, one points to FHSY0 while other
points to a FHSY instance if the carrier frequency of first TRX is
included in the mobile allocation of FHSY instance pointed by
second TRX.
On a DMA layer the FHSYSID cannot be NULL.
OVERLAP_BAND
When the frequency band of the BTS is EXT900 the TRX can
use only the Frequency Hopping sequence in the same band of
the TRXFREQ.


A30808-X3247-M230-6-7619

1499
CML:BSC TRX
Id:0900d805800d46ab
The sub-band of CFHSY pointed must be compatible with
system indicator of TRX.
The value for MAIO must be less than the number of frequen-
cies in the mobile allocation of the FHSY or CFHSY instance
used.
INVALID_MAIO
To set MAIO to a value different by NULL, all subordinate
channels must have the same value of MAIO.
HSCSD_HOPP_INCONSISTENT
TRXs having subordinate channels with the same time slot
number, pointing to the same FHSY or CFHSY instance must
have different values for MAIO attribute.
The attribute BTSHSCSD can be set at TRUE only if the follow-
ing requirements are satisfied:
1) Case Base Band Hopping Mode: on TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM, single
TCHs on timeslot from 1 to 7 must have the same FHSYD and
MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM, different
from the BCCH one, all single TCHs must have the same
FHSYD and MAIO.
EDGE_HOPP_INCONSISTENT
If the EEDGE flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
1) Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, single TCHs on
timeslot from 1 to 7 must have the same FHSYD and MAIO.
If at least one CCCH has already been equipped, the
MOBALLOC of the FHSY object instance cannot contain the
BCCH frequency and all channels on the BCCH-TRX cannot
hop (i.e. FHSYD attribute must be 0).
2) Case Synthesizer Hopping Mode: on every TRX belonging
to the layers contained in ELLPRM/ELLCOM, different from the
BCCH one, all single TCHs must have the same FHSYD and
MAIO.
EDGE_TSC_INCONSISTENT


1500 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
Application Guidelines:
1. Before setting the value of the TRXFREQ and LAYERID parameters, the TRX object
must be LOCKED.
2. The attribute TRXAREA cannot be set at the NONE value if the CONCELL
parameter (see BTS object) is set at TRUE.
3. The attribute TRXAREA cannot be set at the INNER/COMPLETE values if the
CONCELL parameter (see BTS object) is set at FALSE.
4. The attribute TRXAREA cannot be changed if the TRX is not in LOCKED status.
5. The attribute TRXAREA cannot be set at the INNER value on the TRX with
broadcast functions.
6. The attribute TRXAREA cannot be set at the INNER value if there are subordinated
SDCCH channels on the TRX.
7. The attribute TRXAREA cannot be changed (from INNER to COMPLETE and vice
versa) if the frequency configured as TRXFREQ is used by frequency hopping and
the base band hopping is selected.
8. For the concentric cell it is suggested to set all the txPwrMaxReduction of the inner
or complete area at the same value.
If the EEDGE flag is set at TRUE in the PTPPKF object the fol-
lowing TSC requirements must be satisfied:
- Case Base Band Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, single TCHs on
timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on every TRX belonging to
the layers contained in ELLPRM/ELLCOM, all single TCHs must
have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.
HSCSD_TSC_INCONSISTENT
If the HSCSD service is activated at BTS side (i.e. attribute
BTSHSCSD of BTS object set at TRUE) the following TSC
requirements must be satisfied:
- Case Base Band Hopping Mode: on TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM, single
TCHs on timeslot from 1 to 7 must have the same TSC.
- Case Synthesizer Hopping Mode: on TRX belonging to the
layers contained in HSCSDLLPRM/HSCSDLLCOM all single
TCHs must have the same TSC.
The command is rejected if some TSCs are set at the same
value and the others are skipped.


A30808-X3247-M230-6-7619

1501
CML:BSC TRX
Id:0900d805800d46ab
9. In a GSMDCS or GSM850DCS concentric cell, all the TRXs belonging to the same
band have to belong to the same area (inner or complete).
In a GSMDCS concentric cell it is not possible to change the TRXAREA of a
transceiver. This is due to the fact that in mixed cells to change the TRXAREA will
mean to change the band of the TRX and this cannot be allowed because the HW
of a TRX is not able to manage two different frequency bands.
10. In order to create a TRX the RFLOOP relative to the BTS which the TRX belongs to
must be set at the administrative state LOCKED.
11. In order to set the TRXMD all the subordinate TCHs must be in LOCKED state.
12. If only one 64 kbit/s LAPD channel is created in BSC and BTSE, the number of full
rate and half rate TRXs to be configured is limited and might be lower than the
maximum possible of 24 TRXs, in order not to increase the Call Failure Rate (the
expression 'half(full) rate TRXs' only means "how many TRXs would be covered if
the HR(FR) channels were on the same TRXs"; the intention is to have a practical
and not too detailed result).
The maximum allowed number of configured full rate and half rate TRXs can be
estimated according to the following rule:
2 * (number of half rate TRXs) + (number of full rate TRXs) <= 32.
This rule is valid only if no radio measurements are activated within a BTSM. If two
or more 64 kbit/s LAPD channels are created there is no limitation for the number of
configured TRXs.
13. Special care has to be applied if the RADIOMR attribute is set at ON for several
TRXs. For more details see Appendix B: Group 8.
Example of Command Execution:
Set TRX:NAME=BTSM:0/BTS:0/TRX:0,TRXFREQ=BCCHFREQ,PWRRED=0,
RADIOMR=ON,RADIOMG=2,MOEC=TRUE,TRXAREA=NONE, LPDLMN=0,
TRXMD=GSM, MAIO=<NULL>, FHSYID=<NULL>,LAYERID=LY_11, USFGRAN=DIS-
ABLED;
SHUTDOWN TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX SHUTDOWN
TRX
Applicability:
Phase 2.
Visibility level: 2.
SHUTDOWN TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


1502 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The BSS is able to force a mobile station to perform an intracell, intercell or inter-BSC
HO by means of the O&M SHUTDOWN command. After the SHUTDOWN command is
entered, the system tries to perform an intracell, intercell or inter-BSC HO per mobile
station; in case of failure, a further attempt is performed every 30 seconds for the next
5 minutes period.
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1503
CML:BSC TRX
Id:0900d805800d46ab
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 5.5 minutes ---------->
LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown TRX:NAME=BTSM:0/BTS:0/TRX:0;
UNLOCK TRX
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL BTSM BTS TRX UNLOCK TRX
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)
UNLOCK TRX NAME=BTSM:0..199/BTS:0..23/TRX:0..23;


1504 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d46ab
TRX
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock TRX:NAME=BTSM:0/BTS:0/TRX:0;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1505
CML:BSC TSLA
Id:0900d805800d57bf
TSLA
The TSLA object represents one of the time slots on the A interface.
GET TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GET TSLA
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the TSLA object.
Long Names:
NAME Addres of the managed object
VOLUL volumeUplink
VOLDL volumeDownlink
POOLTYP PoolType
System Responses:
- Operation Completed
GET TSLA BASICS
- Operation Failed
GET TSLA NAME=PCMA:0..191/TSLA:1..31 [,REQATTL= VOLUL
,VOLDL ,POOLTYP];
NAME:name
VOLUL: volumeUpLink
VOLDL:volumeDownLink
POOLTYP:PoolType
NAME:name
VOLUL: volumeUpLink
VOLDL:volumeDownLink
POOLTYP:poolType
NOT_EQUIPPED


1506 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d57bf
TSLA
Application Guidelines:
A command to GET all the TSLA belonging to a PCMA is provided. The command is
GET TSLA-pcman-ALL and return for each TSLA spontaneos message with the same
format of the GET ACK system response excluded the last time slot for which is returned
the GET ACK message. The number of message returned dependes on the PCM type
selected. For PCM30 is returned a message for each time slot from 1 to 31 while for
PCM24 is returned a message for each time slot from 1 to 24.
GET TSLA BASICS
None.
Example of Command Execution:
Get TSLA:NAME=PCMA:0/TSLA:1,REQATTL=VOLUL&VOLDL&POOLTYP;
GET TSLA BASICS
Get TSLA BASICS:NAME=PCMA:0/TSLA:1;
GET TSLA BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GET TSLA BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of the TSLA object.
Long Names:
NAME Addres of the managed object
VOLUL volumeUplink
VOLDL volumeDownlink
POOLTYP PoolType
System Responses:
See GET TSLA
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_TIME_SLOT
The range of address tsln is not compatible with the PCM
line type attribute (parameter PCMTYPE of BSC object).
GET TSLA BASICS NAME=PCMA:0..191/TSLA:1..31;


A30808-X3247-M230-6-7619

1507
CML:BSC TSLA
Id:0900d805800d57bf
Application Guidelines:
See GET TSLA
Example of Command Execution:
See GET TSLA
GET TSLA STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GET TSLA STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
TSLA object:
Administrative State (AST)
Operational State (OST)
Usage State (UST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
Only sets with raised bits are shown.
Example of Command Execution:
Get TSLA STAT:NAME=PCMA:0/TSLA:1;
GET TSLA STAT NAME=PCMA:0..191/TSLA:1..31;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


1508 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d57bf
TSLA
GETRELATIONSHIP TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GETRELATIONSHIP
TSLA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
FMO (Functional Managed Object); the relationship information consist of the all HMOs
(Hardware Managed Object) supporting the FMO functionality. This information is
included in the RELATED_EQUIPMENT_OBJECTS attribute (ATTID parameter).
For the TSLA object the related HMOs are the following: LICD/LICDS, EPWR, BSMS,
TPWR, PPLD, TRAC, PWRD, MPCC, TDPC, MEMT and NTW.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected FMO the list of
related HMOs is displayed (FMO to HMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship TSLA:NAME=PCMA:0/TSLA:1,
ATTID=RELATED_EQUIPMENT_OBJECTS;
GETRELATIONSHIP
TSLA
NAME=PCMA:0..191/TSLA:1..31;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


A30808-X3247-M230-6-7619

1509
CML:BSC TSLA
Id:0900d805800d57bf
GETSUBO TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA GETSUBO TSLA
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the list of direct subordinate objects of a specified
object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The output of the command can be composed by one or more pack with a maximum
number of ten subordinated mnemonics; at the end there a message is displayed noti-
fying the end of the subordinate list.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getsubo TSLA:NAME=PCMA:0/TSLA:1;
LOCK TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA LOCK TSLA
Applicability:
Phase 2.
Visibility level: 1.
GETSUBO TSLA NAME=PCMA:0..191/TSLA:1..31;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
LOCK TSLA NAME=PCMA:0..191/TSLA:1..31;


1510 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d57bf
TSLA
Command Description:
This command allows to set an object to the administrative state "Locked".
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. If object TRX or CHAN is locked, calls using the concerned objects are dropped. To
avoid loss of calls by locking objects TRX or CHAN a request for usage state of this
objects should be done previously (e.g. GET state status). In case returned usage
state is "active" or "busy" locking should not be done (otherwise calls are dropped).
2. The LOCK command is only "force" type and it is always executed no matter what
the configuration of the object is. This is valid for all objects, but MPCC, IXLT,
PWRD, TDPC, MEMT (e.g. a LOCK of a single copy of a PWRD will be rejected).
3. The administrative state Locked will survive at the Full Init (and consequently to the
load database) for a maximum of 200 objects (on a FIFO basis).
Example of Command Execution:
Lock TSLA:NAME=PCMA:0/TSLA:1;
SET TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA SET TSLA
Applicability:
Phase 2.
Visibility level: 2.
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SET TSLA NAME=PCMA:0..191/TSLA:1..31 [,VOLUL=] [,VOLDL=]
[,POOLTYP=];


A30808-X3247-M230-6-7619

1511
CML:BSC TSLA
Id:0900d805800d57bf
Command Description:
This command sets the desired values of the uplink and downlink volumes on a
specified couple pcma_line-time_slot_number (previously created).
Long Names:
NAME Addres of the managed object
VOLUL volumeUplink
VOLDL volumeDownlink
POOLTYP PoolType
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
When the EPOOL parameter of the BSC object is set to TRUE, if all the TSLAs of a
TRAU are set to the NOT-DEFINED value, all TRAC boards of this TRAU go to cold
standby state, and the TRAU loses its functionality.
UNSUCCESSFUL_INVALID_TIME_SLOT
Time slot 0 is not allowed.
The range of address tsln is not compatible with the PCM line
type attribute (parameter PCMTYPE of BSC object).
UNSUCCESSFUL_INVALID_ATTRIBUTES
In order to set the POOLTYP attribute the pooling must be
enabled (attribute EPOOL of BSC object).
The attribute POOLTYP cannot assume the value POOL_23
or POOL_46 if the relative TRAU is not AMR and back.
If TRAU is not S3 (fourth digit of EXPSWV attribute is not
'03'), the attribute DEFPOOLTYP cannot assume the values
from POOL_24 to POOL_35 and the values POOL_47 and
POOL_48
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The superordinate PCMA object instance must be already
equipped.
In order to set the POOLTYP attribute the related TRAU
object instance must be in LOCKED state.
NOT_ENOUGH_SUBSLOTS_IN_PCMS
In order to set the POOLTYP attribute there must be enough
PCMS subslots still unmapped to fulfill the request of the new
TSLA pool type.


1512 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d57bf
TSLA
Example of Command Execution:
Set TSLA:NAME=PCMA:0/TSLA:1,THROUGH=4,VOLUL=2,VOLDL=2,
POOLTYP=POOL_1;
SHUTDOWN TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA SHUTDOWN TSLA
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command allows the graceful transition of an object from the administrative state
"Unlocked" to the administrative state "Locked" after the object has terminated its
current activity.
The system attempts to perform the command every 10 seconds for the next 6 minutes.
If after the predefined period (5.5 minutes) the current activity is not terminated, the
administrative state will be set at "Locked". If one of the objects is still "active" or "busy"
after the predefined period, ongoing calls will be dropped.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
SHUTDOWN TSLA NAME=PCMA:0..191/TSLA:1..31;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state LOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1513
CML:BSC TSLA
Id:0900d805800d57bf
Application Guidelines:
1. If the operator has started too many shutdown commands, the system will display
the SM TOO BUSY message.
2. Possible state transitions and timing:
a) UNLOCKED -immediately-> SHUTTING DOWN ---------- immediately ---------->
LOCKED
b) UNLOCKED -immediately-> SHUTTING DOWN ---------- 6 minutes and 10
seconds ----------> LOCKED
c) UNLOCKED -immediately-> SHUTTING DOWN ---------- after object went to idle
state ----------> LOCKED
The state changes described above show all the possible transitions when the
shutdown command was performed.
The first column of the table gives the situations which are affected by doing a
shutdown of an object.
Example of Command Execution:
Shutdown TSLA:NAME=PCMA:0/TSLA:1;
UNLOCK TSLA
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL PCMA TSLA UNLOCK TSLA
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command allows to set an object to the administrative state "Unlocked".
Long Names:
NAME Addres of the managed object
SITUATIONS TRANSITIONS
FORCED/NOT FORCED
idle object a)
busy object but not released after
the SHUTDOWN command
b)
busy object but released after the
SHUTDOWN command
c)
UNLOCK TSLA NAME=PCMA:0..191/TSLA:1..31;


1514 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d57bf
TSLA
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Unlock TSLA:NAME=PCMA:0/TSLA:1;
ALREADY_IN_TARGET_STATE
The object instance is in the administrative state
UNLOCKED.
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.


A30808-X3247-M230-6-7619

1515
CML:BSC X25A
Id:0900d805800d4349
X25A
The X25A object represents the physical link - pcma line number, timeslot number - on
the PCMA interface used to communicate with the external network elements.
CREATE X25A
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A CREATE X25A
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds the object X25A representing the physical link of A interface to
communicate with the external network elements.
Long Names:
NAME Addres of the managed object
ACHAN aChannel
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
LCN2WC lcnOf1st2WayChannels
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PS networkLayerPacketSize
TRACE debuggingCodedString
CREATE X25A NAME=X25A:0..1 ,ACHAN= [,T1=] [,T4=] [,RETRY=]
[,L2WIN=] [,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=]
[,T23=] [,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=]
[,TRACE=] [,N2WC=];


1516 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
N2WC numberOf2WayChannels
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The range of the field tslNumber of the attribute ACHAN is different depending on
the attribute PCMTYPE of the BSC object. If the attribute PCMTYPE is equal to
PCM30, the range is 1..31, otherwise (PCM24) the range is 1..24.
2. In order to create a X25A the related TRAU object must be locked.
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in
order to perform the command.
The objects X25A and X25D are mutually exclusive, i.e. if an
X25A is already EQUIPPED, an X25D cannot be EQUIPPED
and vice versa.
SUPERORDINATE_NOTEQUIPPED
The PCMA used for the link must be already equipped.
UNSUCCESSFUL_INVALID_TIME_SLOT
Make reference to APPLICATION GUIDELINE n. 1.
UNSUCCESSFUL_TIME_SLOT_ALREADY_ALLOCATED
The timeslot of the PCMS to support the SS7L must be free.
The selected TSLA is already carrying a NUC.
UNSUCCESSFUL_INVALID_STATUS
Make reference to APPLICATION GUIDELINES n. 1 and n.
2.
UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED
The creation of copy #1 is subordinated to the presence of
copy #0.
IXLT_NOT_YET_LOCKED
The creation of copy #1 of X25A is possible only if the IXLT -
1 is LOCKED.
INVALID_COMMAND
No mixed configurations are possible, that is, if the IPLI object
is already equipped, a CREATE X25A command is refused.


A30808-X3247-M230-6-7619

1517
CML:BSC X25A
Id:0900d805800d4349
Example of Command Execution:
Create X25A:NAME=X25A:0,ACHAN=0-27,T1=27,T4=200,RETRY=8,
L2WIN=1,LCN2WC=1,L3WIN=1,T20=1000,T21=1000,T22=1800,T23=3000,T26=400,
T28=600,R20=55,R22=4,R23=10,L3PS=Packet_512,TRACE="0101010101";
DELETE X25A
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A DELETE X25A
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the X25A object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
DELETE X25A NAME=X25A:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SUBORDINATE_EQUIPPED
The OMAL and CBCL object instances using the link
associated to the X25 object instance must be previously
deleted.
UNSUCCESSFUL_INVALID_STATUS
Before deleting an X25A, the relative object instance
must be in LOCKED state.
UNSUCCESSFUL_COPY_ONE_EQUIPPED
The deletion of the instance #0 is possible only if the copy
#1 is not present.


1518 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
Application Guidelines:
None.
Example of Command Execution:
Delete X25A:NAME=X25A:0;
GET X25A
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A GET X25A
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of OSI level 1, level 2 and level 3 of
the X25A object.
Long Names:
NAME Addres of the managed object
ACHAN aChannel
L2PV layer2ProtocolVariant
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
PVC pvc
NIOC numberOfIncomingOnly
NOOC numberOfOutgoingOnly
LCNIOC lcnOf1stIncomingOnly
LCN2WC lcnOf1st2WayChannels
LCNOOC lcnOf1stOutgoingOnly
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
GET X25A NAME=X25A:0..1 [,REQATTL= ACHAN ,L2PV ,T1 ,T4
,RETRY ,L2WIN ,PVC ,NIOC ,NOOC ,LCNIOC ,LCN2WC
,LCNOOC ,L3WIN ,T20 ,T21 ,T22 ,T23 ,T26 ,T28 ,R20 ,R22
,R23 ,L3PV ,FCTRL ,L3PS ,TRACE ,N2WC];


A30808-X3247-M230-6-7619

1519
CML:BSC X25A
Id:0900d805800d4349
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PV networkLayerProtocolVariant
FCTRL flowControlNegotiation
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels
System Responses:
- Operation Completed
NAME: name
ACHAN:
pcmaNumber pcmaNumber
tslNumber: timeslotNumber
L2PV: layer2ProtocolVariant
T1: timerT1
T4: timerT4
RETRY: retryNumber
L2WIN: layer2WindowSize
PVC: pvc
NIOC: numberOfIncomingOnly
NOOC: numberOfOutgoingOnly
LCNIOC: lcnOf1stIncomingOnly
LCN2WC: lcnOf1st2WayChannels
LCNOOC: lcnOf1stOutgoingOnly
L3WIN: networkLayerWindowSize
T20: restartRequestTimeout
T21: callRequestTimeout
T22: resetRequestTimeout
T23: clearRequestTimeout
T26: interruptRequestTimeout
T28: registrationRequestTimeout
R20: restartRequestRetryCount
R22: resetRequestRetryCount
R23: clearRequestRetryCount


1520 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
GET X25A BASICS
L3PV: networkLayerProtocolVariant
FCTRL: flowControlNegotiation
L3PS: networkLayerPacketsize
TRACE: debuggingCodedString
N2WC: numberOf2WayChannels
NAME: name
ACHAN:
pcmaNumber pcmaNumber
tslNumber: timeslotNumber
L2PV: layer2ProtocolVariant
T1: timerT1
T4: timerT4
RETRY: retryNumber
L2WIN: layer2WindowSize
PVC: pvc
NIOC: numberOfIncomingOnly
N2WC: numberOf2WayChannels
NOOC: numberOfOutgoingOnly
LCNIOC: lcnOf1stIncomingOnly
LCN2WC: lcnOf1st2WayChannels
LCNOOC: lcnOf1stOutgoingOnly
L3WIN: networkLayerWindowSize
T20: restartRequestTimeout
T21: callRequestTimeout
T22: resetRequestTimeout
T23: clearRequestTimeout
T26: interruptRequestTimeout
T28: registrationRequestTimeout
R20: restartRequestRetryCount
R22: resetRequestRetryCount
R23: clearRequestRetryCount
L3PV: networkLayerProtocolVariant
FCTRL: flowControlNegotiation
L3PS: networkLayerPacketsize


A30808-X3247-M230-6-7619

1521
CML:BSC X25A
Id:0900d805800d4349
- Operation Failed
None.
Application Guidelines:
None.
GET X25A BASICS
None.
Example of Command Execution:
Get X25A:NAME=X25A:0,REQATTL=ACHAN&L2PV&T1&T4&RETRY&L2WIN&
PVC&NIOC&NOOC&LCNIOC&LCN2WC&LCNOOC&L3WIN&T20&T21&
T22&T23&T26&T28&R20&R22&R23&L3PV&FCTRL&L3PS&TRACE&N2WC;
GET X25A BASICS
Get X25A BASICS:NAME=X25A:0;
GET X25A BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A GET X25A BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of OSI level 1, level 2 and level 3 of
the X25A object.
Long Names:
NAME Addres of the managed object
ACHAN aChannel
L2PV layer2ProtocolVariant
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
PVC pvc
NIOC numberOfIncomingOnly
TRACE: debuggingCodedString
GET X25A BASICS NAME=X25A:0..1;


1522 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
NOOC numberOfOutgoingOnly
LCNIOC lcnOf1stIncomingOnly
LCN2WC lcnOf1st2WayChannels
LCNOOC lcnOf1stOutgoingOnly
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PV networkLayerProtocolVariant
FCTRL flowControlNegotiation
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels
System Responses:
See GET X25A
Application Guidelines:
See GET X25A
Example of Command Execution:
See GET X25A
GET X25A STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A GET X25A STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
X25A object:
GET X25A STAT NAME=X25A:0..1;


A30808-X3247-M230-6-7619

1523
CML:BSC X25A
Id:0900d805800d4349
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. TSYNC should be equal to TTRAU parameter.
2. Only sets with raised bits are shown.
3. Explanation of the meaning of OMAL ,IXLT, CBCL, X25A and X25D status:
The handling of the status attributes may be summarized as follows:
Example of Command Execution:
Get X25A STAT:NAME=X25A:0;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
Value X25A
standby PROVIDINGSERVICE not used
HOT STANDBY not used
COLD STANDBY not used
NULL_STATUS not used
availability FAILED layer 2 is down
DEGRADED not used
OFF_DUTY not used
DEPENDENCY if PCMA is LOCKED or DISABLED
procedural INITIALIZING not used
X25A
ENABLED layer 2 up
DISABLED layer 2 down


1524 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
GETINFO X25A
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A GETINFO X25A
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the whole set of information regarding the X25A
object; the given information is organized as follows:
For each X25 copies:
1. X25 type: if the X25 is connected via Asub (X25A) or in dedicated way (X25D);
2. X25 Number: it's the copy of X25;
3. IXLT Number: it's the copy of IXLT that support the X25 link;
4. X25 Operational State
5. X25 Availability Status;
6. PPXX Number: it's the number of PPXL card that support the LPDLS;
7. PCMS Number: it's the number of PCMS where the TRAU is connected to;
8. LICD Number: it's the number of LICD card where the PCMS is connected to
9. LICD circuit: it's the number of LICD circuit where the PCMS is connected to;
10. PCMA Number: it's the PCMA where the X25A is connected;
11. TRAU Number : it's the number of TRAU where the PCMA is connected to;
12. TRAU circuit: it's the number of TRAU circtuit where the PCMA is connected to.
For each OMAL copies:
1. OMAL Number: it's the copy of OMAL;
2. IXLT Number: it's the copy of IXLT that support the OMAL link;
3. OMAL Operational State;
4. OMAL Availability Status;
5. OMAL Standby Status;
6. Service Type;
7. Ftam Connection number.
For each CBCL copies:
1. CBCL Number: it's the copy of CBCL;
2. IXLT Number: it's the copy of IXLT that support the CBCL link;
3. CBCL Administrative State;
4. CBCL Operational State;
5. CBCL Availability Status;
GETINFO X25A NAME=X25A:0..1;


A30808-X3247-M230-6-7619

1525
CML:BSC X25A
Id:0900d805800d4349
6. CBCL Standby Status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
X25A 0: (X25 TYPE and NUMBER)
IXLT NUMBER: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PPXX: 0
PCMS: 0
LICD: 9 - 5 (LICD NR - LICD CIRC)
PCMA: 0
TRAU-CIRCUIT: 0 - 1 (TRAU NR - PCMT NR)
X25A 1:
IXLT NUMBER: 1
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PCMS: 0
LICD: 9 - 5 (LICD NR - LICD CIRC)
PCMA: 0
TRAU-CIRCUIT: 0 - 1 (TRAU NR - PCMT NR)
OMAL 0:
IXLT NUMBER: 1
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
SERVICE TYPE: CMIP
OMAL 1:
IXLT NUMBER: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
SERVICE TYPE: FTAM
FTAM CONNECTION: 1


1526 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
CBCL 0:
IXLT NUMBER: 0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
CBCL 1:
IXLT NUMBER: 0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
END OF REPORT
- Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Getinfo X25A:NAME=X25A:0;
GETRELATIONSHIP X25A
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A GETRELATIONSHIP X25A
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of all the FMOs
(Functional Managed Object) using the HMO service.

For the X25A object the CBCL and OMAL are the related FMOs.
GETRELATIONSHIP
X25A
NAME=X25A:0..1;


A30808-X3247-M230-6-7619

1527
CML:BSC X25A
Id:0900d805800d4349
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Getrelationship X25A:NAME=X25A:0;
SET X25A
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25A SET X25A
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the parameters for the OSI level 2 and level 3 of X25A.
Long Names:
NAME Addres of the managed object
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
LCN2WC lcnOf1st2WayChannels
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.
SET X25A NAME=X25A:0..1 [,T1=] [,T4=] [,RETRY=] [,L2WIN=]
[,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=] [,T23=]
[,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=] [,TRACE=]
[,N2WC=];


1528 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d4349
X25A
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The value assigned to the timer t4 must be greater than the value of timer t1 or could
be equal to 0.The value 0 assigned to the timer indicates that the timer is not
managed.
2. The following rules must be respected:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to APPLICATION GUIDELINES n. 1 and n.
2.
[(LCNIOC)...(LCNIOC+NIOC-1)] not intersected to (only for NIOC!=0)
[(LCN2WC)...(LCN2WC+N2WC-1)] not intersected to (only for N2WC!=0)
[(LCNOOC)...(LCNOOC+NOOC-1)] not intersected to (only for NOOC!=0)
[(PVC)]
E.g LCNIOC=1, NIOC=3
LCN2WC=4, N2WC=6
LCNOOC=10,NOOC=7
PVC=17


A30808-X3247-M230-6-7619

1529
CML:BSC X25A
Id:0900d805800d4349
Example of Command Execution:
Set X25A:NAME=X25A:X25A:0,T1=27,T4=200,RETRY=8,L2WIN=1,LCN2WC=1,
L3WIN=1,T20=1000,T21=1000,T22=1800,T23=3000,T26=400,T28=600,R20=255,
R22=4,R23=10,L3PS=Packet_512, TRACE=0101010101;


1530 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
X25D
X25D represents the physical link of a dedicated line used for communication with the
external network elements.
CREATE X25D
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D CREATE X25D
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds the object X25D representing the physical link of a dedicated line
used to communicate with the external network elements.
Long Names:
NAME Addres of the managed object
CLOCK clock
BAUDRATE baudRate
DTEDCE dteDce
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
LCN2WC lcnOf1st2WayChannels
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
CREATE X25D NAME=X25D:0..1 [,CLOCK=] [,BAUDRATE=] [,DTEDCE=]
[,T1=] [,T4=] [,RETRY=] [,L2WIN=] [,LCN2WC=] [,L3WIN=]
[,T20=] [,T21=] [,T22=] [,T23=] [,T26=] [,T28=] [,R20=]
[,R22=] [,R23=] [,L3PS=] [,TRACE=] [,N2WC=];


A30808-X3247-M230-6-7619

1531
CML:BSC X25D
Id:0900d805800d434c
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels
System Responses:
- Operation Completed
Successful
- Operation Failed
Application Guidelines:
1. The CLOCK parameter must be set to EXTERNAL: in this case an external clock is
used for RC-BSC conversation. If the CLOCK parameter is set at INTERNAL, an
internal clock generated from IXLT is used. The usage of the internal clock leads to
a Network switch every 30 seconds.
2. In case of RC-BSC connection by means of routers it is recommended to set T1, T4
and RETRY parameters at default values, in order to have a correct behaviour.
Example of Command Execution:
Create X25D:NAME=X25D:0,CLOCK=EXTERNAL,BAUDRATE=Baud_64000,
DTEDCE=DCE,T1=27,T4=200,RETRY=8,L2WIN=1,LCN2WC=1,L3WIN=1,T20=1000,
T21=1000,T22=1800,T23=3000,T26=400,T28=600,R20=255,R22=4,R23=10,
L3PS=Packet_512,TRACE=0101010101;
DELETE X25D
NACK CAUSES:
OBJECT_ALREADY_EQUIPPED
The instance of the object must not be already created in order
to perform the command.
The objects X25A and X25D are mutually exclusive, i.e. if an
X25A is already EQUIPPED, an X25D cannot be EQUIPPED
and vice versa.
UNSUCCESSFUL_COPY_ZERO_NOTEQUIPPED
The creation of copy #1 is subordinated to the presence of copy
#0.
IXLT_NOT_YET_LOCKED
The creation of copy #1 of X25D is possible only if the IXLT-1 is
LOCKED.
INVALID_COMMAND
No mixed configurations are possible, that is, if the IPLI object
is already equipped, a CREATE X25D command is refused.
DELETE X25D NAME=X25D:0..1;


1532 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D DELETE X25D
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the X25D object.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
Example of Command Execution:
Delete X25D:NAME=X25D:0;
GET X25D
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D GET X25D
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
SUBORDINATE_EQUIPPED
The OMAL and CBCL object instances using the link
associated to the X25 object instance must be previously
deleted.
UNSUCCESSFUL_COPY_ONE_EQUIPPED
The deletion of the instance #0 is possible only if the copy
#1 is not present.
GET X25D NAME=X25D:0..1 [,REQATTL= CLOCK ,BAUDRATE
,DTEDCE ,L2PV ,T1 ,T4 ,RETRY ,L2WIN ,PVC ,NIOC
,NOOC ,LCNIOC ,LCN2WC ,LCNOOC ,L3WIN ,T20 ,T21
,T22 ,T23 ,T26 ,T28 ,R20 ,R22 ,R23 ,L3PV ,FCTRL ,L3PS
,TRACE ,N2WC];


A30808-X3247-M230-6-7619

1533
CML:BSC X25D
Id:0900d805800d434c
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of OSI level 1, level 2 and level 3 of
the X25D object.
Long Names:
NAME Addres of the managed object
CLOCK clock
BAUDRATE baudRate
DTEDCE dteDce
L2PV layer2ProtocolVariant
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
PVC pvc
NIOC numberOfIncomingOnly
NOOC numberOfOutgoingOnly
LCNIOC lcnOf1stIncomingOnly
LCN2WC lcnOf1st2WayChannels
LCNOOC lcnOf1stOutgoingOnly
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PV networkLayerProtocolVariant
FCTRL flowControlNegotiation
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels


1534 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
System Responses:
- Operation Completed
GET X25D BASICS
NAME: name
CLOCK: clock
BAUDRATE: baudrate
DTEDCE: dteDce
L2PV: layer2ProtocolVariant
T1: timerT1
T4: timerT4
RETRY: retryNumber
L2WIN: layer2WindowSize
PVC: pvc
NIOC: numberOfIncomingOnly
NOOC: numberOfOutgoingOnly
LCNIOC: lcnOf1stIncomingOnly
LCN2WC: lcnOf1st2WayChannels
LCNOOC: lcnOf1stOutgoingOnly
L3WIN: networkLayerWindowSize
T20: restartRequestTimeout
T21: callRequestTimeout
T22: resetRequestTimeout
T23: clearRequestTimeout
T26: interruptRequestTimeout
T28: registrationRequestTimeout
R20: restartRequestRetryCount
R22: resetRequestRetryCount
R23: clearRequestRetryCount
L3PV: networkLayerProtocolVariant
FCTRL: flowControlNegotiation
L3PS: networkLayerPacketsize
TRACE: debuggingCodedString
N2WC: numberOf2WayChannels
NAME: name


A30808-X3247-M230-6-7619

1535
CML:BSC X25D
Id:0900d805800d434c
- Operation Failed
None.
Application Guidelines:
None.
GET X25D BASICS
None.
CLOCK: clock
BAUDRATE: baudrate
DTEDCE: dteDce
L2PV: layer2ProtocolVariant
T1: timerT1
T4: timerT4
RETRY: retryNumber
L2WIN: layer2WindowSize
PVC: pvc
NIOC: numberOfIncomingOnly
N2WC: numberOf2WayChannels
NOOC: numberOfOutgoingOnly
LCNIOC: lcnOf1stIncomingOnly
LCN2WC: lcnOf1st2WayChannels
LCNOOC: lcnOf1stOutgoingOnly
L3WIN: networkLayerWindowSize
T20: restartRequestTimeout
T21: callRequestTimeout
T22: resetRequestTimeout
T23: clearRequestTimeout
T26: interruptRequestTimeout
T28: registrationRequestTimeout
R20: restartRequestRetryCount
R22: resetRequestRetryCount
R23: clearRequestRetryCount
L3PV: networkLayerProtocolVariant
FCTRL: flowControlNegotiation
L3PS: networkLayerPacketsize
TRACE: debuggingCodedString


1536 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
Example of Command Execution:
Get X25D:NAME=X25D:0,REQATTL=CLOCK&BAUDRATE&DTEDCE&L2PV&
T1&T4&RETRY&L2WIN&PVC&NIOC&NOOC&LCNIOC&LCN2WC&
LCNOOC&L3WIN&T20&T21&T22&T23&T26&T28&R20&R22&R23&L3PV&FCTRL&
L3PS&TRACE&N2WC;
GET X25D BASICS
Get X25D BASICS:NAME=X25D:0;
GET X25D BASICS
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D GET X25D BASICS
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the parameters of OSI level 1, level 2 and level 3 of
the X25D object.
Long Names:
NAME Addres of the managed object
CLOCK clock
BAUDRATE baudRate
DTEDCE dteDce
L2PV layer2ProtocolVariant
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
PVC pvc
NIOC numberOfIncomingOnly
NOOC numberOfOutgoingOnly
LCNIOC lcnOf1stIncomingOnly
LCN2WC lcnOf1st2WayChannels
LCNOOC lcnOf1stOutgoingOnly
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
GET X25D BASICS NAME=X25D:0..1;


A30808-X3247-M230-6-7619

1537
CML:BSC X25D
Id:0900d805800d434c
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PV networkLayerProtocolVariant
FCTRL flowControlNegotiation
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels
System Responses:
See GET X25D
Application Guidelines:
See GET X25D
Example of Command Execution:
See GET X25D
GET X25D STAT
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D GET X25D STAT
Applicability:
Phase 2.
Visibility level: 0.
Command Description:
This command is used to retrieve the following State/Status attributes related to the
X25D object:
Operational State (OST)
Alarm Status (ALS)
Availability Status (AVS)
Control Status (CTS)
Unknown Status (UNK).
GET X25D STAT NAME=X25D:0..1;


1538 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
None.
- Operation Failed
NACK CAUSES:
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
Application Guidelines:
1. TSYNC should be equal to TTRAU parameter.
2. Only sets with raised bits are shown.
3. Explanation of the meaning of OMAL ,IXLT, CBCL, X25A and X25D status:
The handling of the status attributes may be summarized as follows:
Example of Command Execution:
Get X25D STAT:NAME=X25D:0;
GETINFO X25D
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D GETINFO X25D
Value X25D
standby PROVIDINGSERVICE not used
HOT STANDBY not used
COLD STANDBY not used
NULL_STATUS not used
availability FAILED layer 2 is down
DEGRADED not used
OFF_DUTY not used
DEPENDENCY not used
procedural INITIALIZING not used
X25D
ENABLED layer 2 up
DISABLED layer 2 down
GETINFO X25D NAME=X25D:0..1;


A30808-X3247-M230-6-7619

1539
CML:BSC X25D
Id:0900d805800d434c
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to retrieve the whole set of information regarding the X25D
object; the given information is organized as follows:
For each X25 copies:
1. X25 type: if the X25 is connected via Asub (X25A) or in dedicated way (X25D);
2. X25 Number: it's the copy of X25;
3. IXLT Number: it's the copy of IXLT that support the X25 link;
4. X25 Operational State
5. X25 Availability Status.
For each OMAL copies:
1. OMAL Number: it's the copy of OMAL;
2. IXLT Number: it's the copy of IXLT that support the OMAL link;
3. OMAL Operational State;
4. OMAL Availability Status;
5. OMAL Standby Status;
6. Service Type;
7. Ftam Connection number.
For each CBCL copies:
1. CBCL Number: it's the copy of CBCL;
2. IXLT Number: it's the copy of IXLT that support the CBCL link;
3. CBCL Administrative State;
4. CBCL Operational State;
5. CBCL Availability Status;
6. CBCL Standby Status.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
X25D 0: (X25 TYPE and NUMBER)
IXLT NUMBER: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
PPXX: 0
PCMS: 0
LICD: 9 - 5 (LICD NR - LICD CIRC)


1540 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
PCMA: 0
TRAU-CIRCUIT: 0 - 1 (TRAU NR - PCMT NR)
X25D 1:
IXLT NUMBER: 1
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
OMAL 0:
IXLT NUMBER: 1
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
SERVICE TYPE: CMIP
OMAL 1:
IXLT NUMBER: 0
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
SERVICE TYPE: FTAM
FTAM CONNECTION: 1
CBCL 0:
IXLT NUMBER: 0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
CBCL 1:
IXLT NUMBER: 0
ADMINISTRATIVE STATE: UNLOCKED
OPERATIONAL STATE: ENABLED
AVAILABILITY STATUS: NONE
STANDBY STATUS: NONE
END OF REPORT
- Operation Failed


A30808-X3247-M230-6-7619

1541
CML:BSC X25D
Id:0900d805800d434c
None.
Application Guidelines:
None.
Example of Command Execution:
Getinfo X25D:NAME=X25D:0;
GETRELATIONSHIP X25D
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D GETRELATIONSHIP X25D
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardware Managed Object); the relationship information consist of the all FMOs
(Functional Managed Object) using the HMO service.
For the X25D object the CBCL and OMAL are the related FMOs.
Long Names:
NAME Addres of the managed object
System Responses:
- Operation Completed
The functional relationship information is provided: for the selected HMO the list of
related FMOs is displayed (HMO to FMO relationship).
- Operation Failed
NACK CAUSES:
Application Guidelines:
None.
GETRELATIONSHIP
X25D
NAME=X25D:0..1;
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
The managed object does not provide any relationship attribute.


1542 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d434c
X25D
Example of Command Execution:
Getrelationship X25D:NAME=X25D:0;
SET X25D
Command Tree:
MANAGED-ELEMENT BSS-FUNCTIONAL X25D SET X25D
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the parameters for the OSI level 2 and level 3 of X25D.
Long Names:
NAME Addres of the managed object
T1 timerT1
T4 timer4
RETRY retryNumber
L2WIN layer2WindowSize
LCN2WC lcnOf1st2WayChannels
L3WIN networkLayerWindowSize
T20 restartRequestTimeout
T21 callRequestTimeout
T22 resetRequestTimeout
T23 clearRequestTimeout
T26 interruptRequestTimeout
T28 registrationRequestTimeout
R20 restartRequestRetryCount
R22 resetRequestRetryCount
R23 clearRequestRetryCount
L3PS networkLayerPacketSize
TRACE debuggingCodedString
N2WC numberOf2WayChannels
System Responses:
- Operation Completed
SET X25D NAME=X25D:0..1 [,T1=] [,T4=] [,RETRY=] [,L2WIN=]
[,LCN2WC=] [,L3WIN=] [,T20=] [,T21=] [,T22=] [,T23=]
[,T26=] [,T28=] [,R20=] [,R22=] [,R23=] [,L3PS=] [,TRACE=]
[,N2WC=];


A30808-X3247-M230-6-7619

1543
CML:BSC X25D
Id:0900d805800d434c
Successful
- Operation Failed
NACK CAUSES:
Application Guidelines:
1. The value assigned to the timer t4 must be greater than the value of timer t1 or could
be equal to 0.
The value 0 of timer t4 indicates that the timer is not managed.
2. The following rules must be respected:
Example of Command Execution:
Set X25D:NAME=X25D:0,T1=27,T4=200,RETRY=8,L2WIN=1,LCN2WC=1,
L3WIN=1,T20=1000,T21=1000,T22=1800,T23=3000,T26=400,T28=600,
R20=255,R22=4,R23=10,L3PS=Packet_512,TRACE=0101010101
UNSUCCESSFUL_OBJECT_NOTEQUIPPED
The object instance must be already equipped.
UNSUCCESSFUL_INVALID_ATTRIBUTES
Make reference to APPLICATION GUIDELINES n. 1 and n.
2.
[(LCNIOC)...(LCNIOC+NIOC-1)] not intersected to (only for NIOC!=0)
[(LCN2WC)...(LCN2WC+N2WC-1)] not intersected to (only for N2WC!=0)
[(LCNOOC)...(LCNOOC+NOOC-1)] not intersected to (only for NOOC!=0)
[(PVC)]
E.g LCNIOC=1, NIOC=3
LCN2WC=4, N2WC=6
LCNOOC=10,NOOC=7
PVC=17


1544 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
3 BTS and TRAU Objects and Commands
g For all BTS commands, if the user has selected a BTS family interface (e.g BTSEP)
and then in the related commands he uses a BTS instance that refers to a BTS
belonging to another BTS family (e.g. BTSEEM), the following Nack Cause is dis-
played: SWLOAD_NOT_BELONG_TO_BTSE.
g The BTSE, BTSEP, BTSEEM and BTSEXS icons allow the user to access to three
different containment sub-trees, one belonging to BR6.x release, one belonging to
BR7.0 release and the last belonging to BR8.0 release (this is due to the fact that
the SW of the BR8.0 BSC is backward compatible with BTS BR6.x and BR8.0 SW
Versions).
Hereafter the main characteristics of the different equipments are presented. A
detailed list of objects and related commands, available for the user from BSC, will
follow.
g The LMU function is no longer supported. Please do not use any LMU commands.
3.1 BTSE
The Open InterWorking function allows the operator to have access to the containment
sub-tree of the 1st generation BTS equipment, to perform the interworking commands.
The following types of BTS equipment can be selected:
BS-20
BS-21E
BS-22
BS-60
BS-61E
3.2 BTSEP
The Open InterWorking function allows the operator to have access to the containment
sub-tree of the BTS Plus equipment, to perform the interworking commands.
The following types of BTS equipment can be selected:
BS-240
BS-240SR
BS-241
BS-241SR
BS-240XL
BS-240XL SR
BS-40
BS-41.
BS-40 II
BS-82 II
3.3 BTSEEM
The Open InterWorking function allows the operator to have access to the
containment sub-tree of the BTS Enhanced Micro (BS-82) equipment, to perform the
interworking commands.


A30808-X3247-M230-6-7619

1545
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
3.4 BTSEXS
The Open InterWorking function allows the operator to have access to the
containment sub-tree of the BS-240XS equipment, to perform the interworking com-
mands.
The following types of BTS equipment can be selected:
BS-240XS
BS-288
3.5 TRAUE
The Open InterWorking function allows the operator to have access to the
containment sub-tree of the TRAU equipment, to perform the interworking commands.
g The number of TRAUs inside the BSC has handled in the following way:
- up to 32 TRAUs in case of high capacity BSCs with the old rack
- up to 48 TRAUs in case of high capacity BSCs with the new rack
g The GETACTIVEALARMS command brings different results at BSC side
(interworking LMT command) and TRAU side (local LMT command).
The TRAU LMT must be used to have all the TRAU active alarms.
3.6 BTS and TRAU Objects and Commands
3.6.1 BTSE
ACDC
CREATE ACDC
DELETE ACDC
GET ACDC
GETTEST ACDC
LOCK ACDC
PERFTEST ACDC
STOPTEST ACDC
UNLOCK ACDC
ACOM
CREATE ACOM
DELETE ACOM
GET ACOM
GETTEST ACOM
LOCK ACOM
PERFTEST ACOM
SET ACOM


1546 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
STOPTEST ACOM
UNLOCK ACOM
ALCO
GET ALCO
GETTEST ALCO
LOCK ALCO
PERFTEST ALCO
STOPTEST ALCO
UNLOCK ALCO
BBSIG
CREATE BBSIG
DELETE BBSIG
GET BBSIG
GETTEST BBSIG
LOCK BBSIG
PERFTEST BBSIG
SET BBSIG
STOPTEST BBSIG
UNLOCK BBSIG
BPORT
CREATE BPORT
DELETE BPORT
GET BPORT
LOCK BPORT
SET BPORT
UNLOCK BPORT
BTSE
GET BTSE NOSWL
GET BTSE SWL
GETACTIVEALARMS BTSE
PERFTEST BTSE
SET BTSE
STOPTEST BTSE
BTSETEST
GET BTSETEST
CCLK


A30808-X3247-M230-6-7619

1547
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
GET CCLK
CCTRL
GET CCTRL
ENVABTSE
CREATE ENVABTSE
DELETE ENVABTSE
GET ENVABTSE
LOCK ENVABTSE
SET ENVABTSE
UNLOCK ENVABTSE
FAN
CREATE FAN
DELETE FAN
GET FAN
GETTEST FAN
LOCK FAN
PERFTEST FAN
STOPTEST FAN
UNLOCK FAN
FTNF
CREATE FTNF
DELETE FTNF
GET FTNF
GETTEST FTNF
LOCK FTNF
PERFTEST FTNF
STOPTEST FTNF
UNLOCK FTNF
FVSWR
CREATE FVSWR
DELETE FVSWR
GET FVSWR
GETTEST FVSWR
LOCK FVSWR
PERFTEST FVSWR
STOPTEST FVSWR


1548 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
UNLOCK FVSWR
GPSU
GET GPSU
LAPDLE
CREATE LAPDLE
DELETE LAPDLE
GET LAPDLE
LI
GET LI
SET LI
PA
CREATE PA
DELETE PA
GET PA
GETTEST PA
LOCK PA
PERFTEST PA
STOPTEST PA
UNLOCK PA
RACK
GET RACK
RXAMOD
CREATE RXAMOD
DELETE RXAMOD
GET RXAMOD
GETTEST RXAMOD
LOCK RXAMOD
PERFTEST RXAMOD
STOPTEST RXAMOD
UNLOCK RXAMOD
RXMUCO
CREATE RXMUCO
DELETE RXMUCO
GET RXMUCO
GETTEST RXMUCO
LOCK RXMUCO


A30808-X3247-M230-6-7619

1549
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
3.6.2 BTSEEM
PERFTEST RXMUCO
SET RXMUCO
STOPTEST RXMUCO
UNLOCK RXMUCO
TPU
CREATE TPU
DELETE TPU
GET TPU
GETTEST TPU
LOCK TPU
PERFTEST TPU
SET TPU
STOPTEST TPU
UNLOCK TPU
XCONNECT
CREATE XCONNECT
DELETE XCONNECT
GET XCONNECT
LOCK XCONNECT
SET XCONNECT
UNLOCK XCONNECT
ACDCP
CREATE ACDCP
DELETE ACDCP
GET ACDCP
GETTEST ACDCP
LOCK ACDCP
PERFTEST ACDCP
STOPTEST ACDCP
UNLOCK ACDCP
ACT
CREATE ACT
DELETE ACT


1550 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
GET ACT
GETTEST ACT
LOCK ACT
PERFTEST ACT
STOPTEST ACT
UNLOCK ACT
BATTERY
CREATE BATTERY
DELETE BATTERY
GET BATTERY
GETTEST BATTERY
LOCK BATTERY
PERFTEST BATTERY
STOPTEST BATTERY
UNLOCK BATTERY
BPORT
CREATE BPORT
DELETE BPORT
GET BPORT
LOCK BPORT
SET BPORT
UNLOCK BPORT
BTSEEM
GET BTSEEM NOSWL
GET BTSEEM SWL
GETACTIVEALARMS BTSEEM
PERFTEST BTSEEM
SET BTSEEM
STOPTEST BTSEEM
BTSETEST
GET BTSETEST
COBA
GET COBA
GETTEST COBA
SET COBA
CU


A30808-X3247-M230-6-7619

1551
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
CREATE CU
DELETE CU
GET CU WIRING
GET CU
GETTEST CU
LOCK CU
PERFTEST CU
SET CU
STOPTEST CU
UNLOCK CU
DILNA
CREATE DILNA
DELETE DILNA
GET DILNA
GETTEST DILNA
LOCK DILNA
PERFTEST DILNA
SET DILNA
STOPTEST DILNA
UNLOCK DILNA
DULNA
CREATE DULNA
DELETE DULNA
GET DULNA
GETTEST DULNA
LOCK DULNA
PERFTEST DULNA
STOPTEST DULNA
UNLOCK DULNA
DUVSWR
CREATE DUVSWR
DELETE DUVSWR
GET DUVSWR
GETTEST DUVSWR
LOCK DUVSWR
PERFTEST DUVSWR


1552 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
SET DUVSWR
STOPTEST DUVSWR
UNLOCK DUVSWR
ENVABTSE
CREATE ENVABTSE
DELETE ENVABTSE
GET ENVABTSE
LOCK ENVABTSE
SET ENVABTSE
UNLOCK ENVABTSE
FANP
CREATE FANP
DELETE FANP
GET FANP
GETTEST FANP
LOCK FANP
PERFTEST FANP
STOPTEST FANP
UNLOCK FANP
LAPDLE
CREATE LAPDLE
DELETE LAPDLE
GET LAPDLE
RACK
CREATE RACK
DELETE RACK
GET RACK
LOCK RACK
UNLOCK RACK
XCONNECT
CREATE XCONNECT
DELETE XCONNECT
GET XCONNECT
LOCK XCONNECT
SET XCONNECT
UNLOCK XCONNECT


A30808-X3247-M230-6-7619

1553
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
3.6.3 BTSEP
ACDCP
CREATE ACDCP
DELETE ACDCP
GET ACDCP
GETTEST ACDCP
LOCK ACDCP
PERFTEST ACDCP
STOPTEST ACDCP
UNLOCK ACDCP
ACT
CREATE ACT
DELETE ACT
GET ACT
GETTEST ACT
LOCK ACT
PERFTEST ACT
STOPTEST ACT
UNLOCK ACT
BATTERY
CREATE BATTERY
DELETE BATTERY
GET BATTERY
GETTEST BATTERY
LOCK BATTERY
PERFTEST BATTERY
STOPTEST BATTERY
UNLOCK BATTERY
BPORT
CREATE BPORT
DELETE BPORT
GET BPORT
LOCK BPORT
SET BPORT
UNLOCK BPORT


1554 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
BTSEP
GET BTSEP SWL
GET BTSEP NOSWL
GETACTIVEALARMS BTSEP
PERFTEST BTSEP
SET BTSEP
STOPTEST BTSEP
BTSETEST
GET BTSETEST
COBA
CREATE COBA
DELETE COBA
GET COBA
GETRELATIONSHIP COBA
GETTEST COBA
LOCK COBA
PERFTEST COBA
SET COBA
STOPTEST COBA
SWITCH COBA
UNLOCK COBA
COSA
CREATE COSA
DELETE COSA
GET COSA
GETTEST COSA
LOCK COSA
PERFTEST COSA
STOPTEST COSA
UNLOCK COSA
CU
CREATE CU
DELETE CU
GET CU
GET CU WIRING
GETTEST CU


A30808-X3247-M230-6-7619

1555
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
LOCK CU
PERFTEST CU
SET CU
STOPTEST CU
UNLOCK CU
DIDCTMA
CREATE DIDCTMA
DELETE DIDCTMA
GET DIDCTMA
GETTEST DIDCTMA
LOCK DIDCTMA
PERFTEST DIDCTMA
STOPTEST DIDCTMA
UNLOCK DIDCTMA
DILNA
CREATE DILNA
DELETE DILNA
GET DILNA
GETTEST DILNA
LOCK DILNA
PERFTEST DILNA
SET DILNA
STOPTEST DILNA
UNLOCK DILNA
DUDCTMA
CREATE DUDCTMA
DELETE DUDCTMA
GET DUDCTMA
GETTEST DUDCTMA
LOCK DUDCTMA
PERFTEST DUDCTMA
STOPTEST DUDCTMA
UNLOCK DUDCTMA
DULNA
CREATE DULNA
DELETE DULNA


1556 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
GET DULNA
GETTEST DULNA
LOCK DULNA
PERFTEST DULNA
SET DULNA
STOPTEST DULNA
UNLOCK DULNA
DUVSWR
CREATE DUVSWR
DELETE DUVSWR
GET DUVSWR
GETTEST DUVSWR
LOCK DUVSWR
PERFTEST DUVSWR
SET DUVSWR
STOPTEST DUVSWR
UNLOCK DUVSWR
ENVABTSE
CREATE ENVABTSE
DELETE ENVABTSE
GET ENVABTSE
LOCK ENVABTSE
SET ENVABTSE
UNLOCK ENVABTSE
FANP
CREATE FANP
DELETE FANP
GET FANP
GETTEST FANP
LOCK FANP
PERFTEST FANP
STOPTEST FANP
UNLOCK FANP
FCUMAIN
CREATE FCUMAIN
DELETE FCUMAIN


A30808-X3247-M230-6-7619

1557
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
GET FCUMAIN WIRING
GET FCUMAIN
GETTEST FCUMAIN
LOCK FCUMAIN
PERFTEST FCUMAIN
SET FCUMAIN
STOPTEST FCUMAIN
UNLOCK FCUMAIN
FCUTR
CREATE FCUTR
DELETE FCUTR
GETTEST FCUTR
LOCK FCUTR
PERFTEST FCUTR
SET FCUTR
STOPTEST FCUTR
UNLOCK FCUTR
FTNFP
CREATE FTNFP
DELETE FTNFP
GET FTNFP
GETTEST FTNFP
LOCK FTNFP
PERFTEST FTNFP
STOPTEST FTNFP
UNLOCK FTNFP
FVSWRP
CREATE FVSWRP
DELETE FVSWRP
GET FVSWRP
GETTEST FVSWRP
LOCK FVSWRP
PERFTEST FVSWRP
STOPTEST FVSWRP
UNLOCK FVSWRP
LAPDLE


1558 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
CREATE LAPDLE
DELETE LAPDLE
GET LAPDLE
RACK
CREATE RACK
DELETE RACK
GET RACK
LOCK RACK
UNLOCK RACK
SYNCBTSE
GET SYNCBTSE
GETTEST SYNCBTSE
LOCK SYNCBTSE
PERFTEST SYNCBTSE
SET SYNCBTSE
STOPTEST SYNCBTSE
UNLOCK SYNCBTSE
TMA
CREATE TMA
DELETE TMA
GET TMA
GETTEST TMA
LOCK TMA
PERFTEST TMA
STOPTEST TMA
UNLOCK TMA
XCONNECT
CREATE XCONNECT
DELETE XCONNECT
GET XCONNECT
LOCK XCONNECT
SET XCONNECT
UNLOCK XCONNECT


A30808-X3247-M230-6-7619

1559
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
3.6.4 BTSEXS
BCOM
GET BCOM
GETTEST BCOM
LOCK BCOM
PERFTEST BCOM
SET BCOM
STOPTEST BCOM
UNLOCK BCOM
BPORT
CREATE BPORT
DELETE BPORT
GET BPORT
LOCK BPORT
SET BPORT
UNLOCK BPORT
BTSETEST
GET BTSETEST
BTSEXS
GET BTSEXS NOSWL
GET BTSEXS SWL
GETACTIVEALARMS BTSEXS
PERFTEST BTSEXS
SET BTSEXS
STOPTEST BTSEXS
COBA
GET COBA
SET COBA
CU
CREATE CU
DELETE CU
GET CU
GET CU WIRING
GETTEST CU
LOCK CU


1560 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
PERFTEST CU
SET CU
STOPTEST CU
UNLOCK CU
ENVABTSE
CREATE ENVABTSE
DELETE ENVABTSE
GET ENVABTSE
LOCK ENVABTSE
SET ENVABTSE
UNLOCK ENVABTSE
FANP
CREATE FANP
DELETE FANP
GET FANP
GETTEST FANP
LOCK FANP
PERFTEST FANP
STOPTEST FANP
UNLOCK FANP
FCUMAIN
CREATE FCUMAIN
DELETE FCUMAIN
GET FCUMAIN WIRING
GET FCUMAIN
GETTEST FCUMAIN
LOCK FCUMAIN
PERFTEST FCUMAIN
SET FCUMAIN
STOPTEST FCUMAIN
UNLOCK FCUMAIN
FCUTR
CREATE FCUTR
DELETE FCUTR
GETTEST FCUTR
LOCK FCUTR


A30808-X3247-M230-6-7619

1561
CML:BSC BTS and TRAU Objects and Commands
Id:0900d805800d6880
3.6.5 TRAU
PERFTEST FCUTR
SET FCUTR
STOPTEST FCUTR
UNLOCK FCUTR
LAPDLE
CREATE LAPDLE
DELETE LAPDLE
GET LAPDLE
RACK
GET RACK
SYNCBTSE
GET SYNCBTSE
GETTEST SYNCBTSE
LOCK SYNCBTSE
PERFTEST SYNCBTSE
SET SYNCBTSE
STOPTEST SYNCBTSE
UNLOCK SYNCBTSE
XCONNECT
CREATE XCONNECT
DELETE XCONNECT
GET XCONNECT
LOCK XCONNECT
SET XCONNECT
UNLOCK XCONNECT
BSMS
GET BSMS
GETSUBO BSMS
GETTEST BSMS
LOCK BSMS
PERFTEST BSMS
STOPTEST BSMS
SWITCH BSMS


1562 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6880
BTS and TRAU Objects and Commands
UNLOCK BSMS
ENVATRAUE
CREATE ENVATRAUE
DELETE ENVATRAUE
GET ENVATRAUE
LOCK ENVATRAUE
SET ENVATRAUE
UNLOCK ENVATRAUE
TPWR
GET TPWR
GETSUBO TPWR
GETTEST TPWR
LOCK TPWR
PERFTEST TPWR
STOPTEST TPWR
UNLOCK TPWR
TRAC
CREATE TRAC
DELETE TRAC
GET TRAC
GETSUBO TRAC
GETTEST TRAC
LOCK TRAC
PERFTEST TRAC
STOPTEST TRAC
UNLOCK TRAC
TRAUE
GET TRAUE
GETACTIVEALARMS TRAUE
PERFTEST TRAUE
SET TRAUE
STOPTEST TRAUE
TRAUETEST
GET TRAUETEST


A30808-X3247-M230-6-7619

1563
CML:BSC Parameters/Attributes in Alphabetical Order
Id:0900d8058007ce1a
4 Parameters/Attributes in Alphabetical Order


1564 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
a
ABISCH
abisChannel
This attribute identifies the PCM slot allocated for the LapD signalling link, for O&M
messages, at the Abis interface.
When this parameter is used with LPDLR object, it identifies the physical lapd_link
(LPDLM) which the LPDLR created is mapped to.
The slot can be configured as a 64 kbit/s timeslot (the subslot field is skipped), or as a
16 kbit/s timeslot (the subslot field is to be configured).
This parameter consists of the three fields: Pcmb Number, TSL (TimeSlotNumber) and
SSN (SubSlotNumber).
Validity Range
Default Value
Default value for Tsl is None.
Default value for Ssl is NOCONFIG.
Contained in the following commands:
CREATE LPDLM, GET LPDLM
ABISFRACTTHR
abisFullRateActivationThreshold
This parameter defines the threshold that indicates the percentage of busy Abis subslots
(fully busy + half busy + out of service) in the Abis pool that triggers the Load-Based
Decompression HO (from GSM-HR/AHR to GSM-FR/EFR/AFR) in all the cells of the
site where the feature is enabled.
Validity Range
Default Value
40
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
PcmbNumber 0 - 117
Tsl 1 - 31 1..31 for PCM30 line
1..24 for PCM24 line
Ssl 0 - 3
0 - 100
<NULL>


A30808-X3247-M230-6-7619

1565
CML:BSC a
Id:0900d805800ceca9
ABISHRACTTHR
abisHalfRateActivationThreshold
This parameter defines the threshold that indicates the percentage of busy Abis subslots
(fully busy + half busy + out of service) in the Abis pool that triggers the Cell Load Depen-
dent Activation of Half Rate in all the cells of the site where the feature is enabled.
Validity Range
Default Value
60
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
ABISMONTH
abisMonitorThreshold
Default values are referred respectively to: Minor, Major and Critical.
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
0 - 100
<NULL>
This attribute indicates the A-Bis Monitor Thresholds for STSLB.
The threshold is the percentage between out of service STSLB on
equipped STSLB; that is:
ABISMONTH = (STSLB out of service / STSLB equipped)*100
The threshold values can be assigned only when the flag attribute is
set to "enabled".
Minor Disabled 0 - 0
Enabled 1 - 100
Major Disabled 0 - 0
Enabled 1 - 100
Critical Disabled 0 - 0
Enabled 1 - 100
Enabled(30)-Enabled(60)-
Enabled(90)


1566 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ABISTRFHITHR
abisTrafficHighThreshold
This parameter defines the Abis high traffic level threshold. In
combination with the TRFHITH parameter, it is used to establish if handover for traffic
reason has to be enabled/disabled. When the percentage of busy Abis subslots in the
BTSM overcomes the value of the parameter, handover for traffic reason is enabled in
all the BTSs of the site for which TRFHOE is equal to TRUE. In such a case, if an
handover for traffic reason is requested to BSC, it is performed towards a different
BTSM.
Validity Range
Default Value
90
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
ABISTRFLTHR
abisTrafficLowThreshold
This parameter defines the Abis low traffic level in order to establish if a BTSM can be
candidate to receive handover for traffic reason.
Validity Range
Default Value
70
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
ABORT
abort
This attribute defines whether scripts have to abort or not after a FALSE command
(NACK-replied BMML command or failed TEST command).
50 - 100
<NULL>
0 - 80
<NULL>


A30808-X3247-M230-6-7619

1567
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
None.
Contained in the following commands:
EXEC LMT-INTERNAL, SET LMT-INTERNAL
ABUTYP
accessBurstType
This parameter indicates the type of access burst used on uplink PDCH. The value
ACBU8BIT means that 8 bits access burst shall be used by mobile station and
ACBU11BIT means that 11 bits access burst shall be used by mobile station.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
ACBQPFF
acBQPFgtFac
This parameter defines the forgetting factor for the time exponential filter used for BQP
averaging.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACBQPMAX
acBQPMax
This parameter indicates the maximum tolerated BQP in a cell.
NO
YES
ACBU8BIT
ACBU11BIT
ACBU8BIT
0.1 - 1.0 (step size 0.1)
<NULL>


1568 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACCEPTGDEGR
acceptableGPRSDegradation
This attribute defines, in percentage, the acceptable degradation of packet service
throughput (Maximum Sustainable Throughput), before an upgrading of radio resources
is attempted.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ACCTYP
accessType
This attribute identifies the reading format.
2 - 10
<NULL>
PER0
PER10
PER20
PER30
PER40
PER50
PER60
PER70
PER80
PER90
PER0


A30808-X3247-M230-6-7619

1569
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
BYTE
Contained in the following commands:
MEMDUMP BSC
ACEFLFF
acEFLFgtFac
This parameter defines the forgetting factor for the exponential filter used for fractional
load averaging.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACFERMAX
acFERMax
This parameter is the maximum tolerated FER for speech samples taken over 4 SACCH
periods.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACHAN
aChannel
BYTE
WORD
DWORD
0.02 - 0.20 (step size 0.02)
<NULL>
1.0 - 10.0 (step size 0.5)
<NULL>


1570 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
It indicates the pcma line number and the timeslot number used on the "PCMA Inter-
face".
Validity Range
Default Value
None.
Contained in the following commands:
CREATE X25A, GET X25A
ACLNKTYP
acLinkType
This parameter defines the type of sample to be collected and the way they used for the
BQP evaluation.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACMAXEFLDMA
acMaxEFLDMA
This parameter specifies, in percent, the maximum EFL on the DMA layer of the cell.
PcmaNumber 0 - 191
TslNumber 1 - 31 1-31 for PCM30 line
1-24 for PCM24 line
UL_AND_DL_SAMPLES_S
EPARATELY
UL_SAMPLES_ONLY
UL_AND_DL_SAMPLES_
COMMONLY
<NULL>


A30808-X3247-M230-6-7619

1571
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACMINEFLDMA
acMinEFLDMA
This parameter specifies, in percent, the minimun EFL on the DMA layer of the cell.
per_10
per_15
per_20
per_25
per_30
per_35
per_40
per_45
per_50
per_55
per_60
per_65
per_70
per_75
per_80
per_85
per_90
per_95
per_100
<NULL>


1572 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACPER
acPeriod
This parameter is the Admission Control Period in SACCH periods.
per_05
per_10
per_15
per_20
per_25
per_30
per_35
per_40
per_45
per_50
<NULL>


A30808-X3247-M230-6-7619

1573
CML:BSC a
Id:0900d805800ceca9
Validity Range
SACCH_20
SACCH_24
SACCH_28
SACCH_32
SACCH_36
SACCH_40
SACCH_44
SACCH_48
SACCH_52
SACCH_56
SACCH_60
SACCH_64
SACCH_68
SACCH_72
SACCH_76
SACCH_80
SACCH_84
SACCH_88
SACCH_92
SACCH_96
SACCH_100
SACCH_104
SACCH_108
SACCH_112
SACCH_116
SACCH_120
SACCH_124
SACCH_128
SACCH_132
SACCH_136
SACCH_140
SACCH_144
SACCH_148
SACCH_152
SACCH_156


1574 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
SACCH_160
SACCH_164
SACCH_168
SACCH_172
SACCH_176
SACCH_180
SACCH_184
SACCH_188
SACCH_192
SACCH_196
SACCH_200
SACCH_204
SACCH_208
SACCH_212
SACCH_216
SACCH_220
SACCH_224
SACCH_228
SACCH_232
SACCH_236
SACCH_240
SACCH_244
SACCH_248
SACCH_252
SACCH_256
SACCH_260
SACCH_264
SACCH_268
SACCH_272
SACCH_276
SACCH_280
SACCH_284
SACCH_288
SACCH_292
SACCH_296
SACCH_300


A30808-X3247-M230-6-7619

1575
CML:BSC a
Id:0900d805800ceca9
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ACTN
action
This parameter defines the databases assignment.
SACCH_304
SACCH_308
SACCH_312
SACCH_316
SACCH_320
SACCH_324
SACCH_328
SACCH_332
SACCH_336
SACCH_340
SACCH_344
SACCH_348
SACCH_352
SACCH_356
SACCH_360
SACCH_364
SACCH_368
SACCH_372
SACCH_376
SACCH_380
SACCH_384
SACCH_388
SACCH_392
SACCH_396
SACCH_400
<NULL>


1576 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
None.
Contained in the following commands:
SET BSCOSUDB, SET BSCOSUSW
ADVCMPHOOAMR
advComprHOffsetAMR
Definition of the codec specific preference (offset of AMR compared to standard
codecs).
Validity Range
Default Value
6
Contained in the following commands:
GET HAND, SET HAND
AECST
acusticEchoControlActivationStatus
This attribute indicates the Acoustic Echo Control (AEC) feature.
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
AISAT
aInterfaceIsSatellited
RUNNING_ESU
BACKUP_ESU
NEW_ESU
FALLBACK_ESU
-30 - 30 (step 1 dBm)
<NULL>
disabled
enabled
disabled


A30808-X3247-M230-6-7619

1577
CML:BSC a
Id:0900d805800ceca9
This attribute indicates whether the LAPD link on the A interface is satellited or terres-
trial.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALACOUNT
alarmCounter
Threshold of the N alarm count.
Validity Range
Default Value
Contained in the following commands:
CREATE LICD, GET LICD, SET LICD
ALARMT1
alarmTiming1
Threshold of the T1 alarm timer. Default value 200 corresponds to 20 seconds.
Validity Range
Default Value
Contained in the following commands:
CREATE LICD, GET LICD, SET LICD
ALARMT2
alarmTiming2
Threshold of the T2 alarm timer. Default value 10 corresponds to 1 second.
TRUE
FALSE
FALSE
1 - 254
32
2 - 254 (step size 0,1 s)
200


1578 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
Contained in the following commands:
CREATE LICD, GET LICD, SET LICD
ALARMT3
alarmTiming3
Threshold of the T3 alarm timer.
Validity Range
Default Value
Contained in the following commands:
CREATE LICD, GET LICD, SET LICD
ALCST
automaticLevelControlStatus
This attribute enables/disables the Automatic Level Control (ALC) feature.
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
ALCTGTLEV
automaticLevelControlTargetLevel
This attribute indicates the target speech level for the Automatic Level Control. Target
level is applicable to both directions if both enabled. It is possible to choose between
2 - 254 (step size 0,1 s)
10
1 - 254 (step size 5 minutes)
1
disabled
eddonly
eduonly
edudl
disabled


A30808-X3247-M230-6-7619

1579
CML:BSC a
Id:0900d805800ceca9
ITU-T G.169 compliant mode and Siemens Enhanced solution with customizable set-
tings..
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
ALEVFULHO
averagedLevFastULHo
This is an optional parameter that can be set in the Hand Basic Attribute Group. It
defines two averaging parameters for FUHO (Fast Uplink Handover) signal strength
measurements, used for fast uplink handover decision.
The first field, aLevFuHo, defines the averaging window size (that is smaller than the
normal window size), the second one, wLevFuho, indicates the averaging weighting
factor.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
iTU (ITU_T G.169 compliant mode)
m23dBM0
m22dBM0
m21dBM0
m20dBM0
m19dBM0
m18dBM0
m17dBM0
m16dBM0
m15dBM0
m19dBM0
size 1 - 31
weight 1 - 3
size 2
weight 1


1580 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALLCRIT
allocationCriteria
This attribute defines the rule to be used for the transcoder matrix computation.
The NOT_COMPATIBLE_WITH_CROSSCONNECT value can be chosen when Cross
Connectors between BSC and TRAU are not used.
The COMPATIBLE_WITH_CROSSCONNECT value has to be chosen when Cross
Connectors between BSC and TRAU are used; that means that timeslots belonging to
the same PCMA are mapped onto 8 consecutive PCMS timeslots.
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU
ALPHA
alpha
This attribute indicates the ALPHA value applied in the power control algorithm.
The step size is 0.1; the value 0 corresponds to 0.0 and the value 10 corresponds to 1.0.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
ALRMSEVBTS
alarmSeverityBts
This attribute indicates the alarm severity associated to BTS
functional object.
NOT_COMPATIBLE_WITH
_CROSSCONNECT
COMPATIBLE_WITH_CR
OSSCONNECT
NOT_COMPATIBLE_WITH
_CROSSCONNECT
0 - 10 (0.1 step size)
3


A30808-X3247-M230-6-7619

1581
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVBTSM
alarmSeverityBtsm
This attribute indicates the alarm severity associated to BTSM
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVCBCL
alarmSeverityCbcl
This attribute indicates the alarm severity associated to CBCL
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
CRITICAL
MAJOR
MINOR
CRITICAL
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR


1582 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVCPEX
alarmSeverityCPEX
This attribute indicates the alarm severity associated to CPEX
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVDISK
alarmSeverityDisk
This attribute indicates the alarm severity associated to DISK
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVDK40
alarmSeverityDk40
This attribute indicates the alarm severity associated to DK40
equipment object.
CRITICAL
MAJOR
MINOR
MINOR
CRITICAL
MAJOR
MINOR
MAJOR


A30808-X3247-M230-6-7619

1583
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVEPWR
alarmSeverityEpwr
This attribute indicates the alarm severity associated to EPWR
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVES
alarmSeverityES
This attribute indicates the alarm severity associated to ES equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MINOR


1584 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVFAN
alarmSeverityFAN
This attribute indicates the alarm severity associated to FAN
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVFRL
alarmSeverityFrl
This attribute indicates the alarm severity associated to FRL
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVIPLI
alarmSeverityIpli
This attribute indicates the alarm severity associated to IPLI
functional object.
CRITICAL
MAJOR
MINOR
MINOR
CRITICAL
MAJOR
MINOR
MINOR


A30808-X3247-M230-6-7619

1585
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVIXLT
alarmSeverityIxlt
This attribute indicates the alarm severity associated to IXLT
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVLICD
alarmSeverityLicd
This attribute indicates the alarm severity associated to LICD
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MINOR


1586 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVLICDS
alarmSeverityLicds
This attribute indicates the alarm severity associated to LICDS
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVLPDLM
alarmSeverityLpdlm
This attribute indicates the alarm severity associated to LPDLM
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVLPDLR
alarmSeverityLpdlr
This attribute indicates the alarm severity associated to LPDLR
functional object.
CRITICAL
MAJOR
MINOR
MINOR
CRITICAL
MAJOR
MINOR
MAJOR


A30808-X3247-M230-6-7619

1587
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVLPDLS
alarmSeverityLpdls
This attribute indicates the alarm severity associated to LPDLS
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVMEMT
alarmSeverityMemt
This attribute indicates the alarm severity associated to MEMT
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR


1588 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVMPCC
alarmSeverityMpcc
This attribute indicates the alarm severity associated to MPCC
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVNSVC
alarmSeverityNsvc
This attribute indicates the alarm severity associated to NSVC
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVNTW
alarmSeverityNtw
This attribute indicates the alarm severity associated to NTW
equipment object.
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MINOR


A30808-X3247-M230-6-7619

1589
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVOMAL
alarmSeverityOmal
This attribute indicates the alarm severity associated to OMAL
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVPCMA
alarmSeverityPcma
This attribute indicates the alarm severity associated to PCMA
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR


1590 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVPCMB
alarmSeverityPcmb
This attribute indicates the alarm severity associated to PCMB
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVPCMG
alarmSeverityPcmg
This attribute indicates the alarm severity associated to PCMG
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVPCMS
alarmSeverityPcms
This attribute indicates the alarm severity associated to PCMS
functional object.
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR


A30808-X3247-M230-6-7619

1591
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVPCU
alarmSeverityPcu
This attribute indicates the alarm severity associated to PCU
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVPPXL
alarmSeverityPpxl
This attribute indicates the alarm severity associated to PPXL
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
CRITICAL
CRITICAL
MAJOR
MINOR
MAJOR


1592 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVPPXU
alarmSeverityPpxu
This attribute indicates the alarm severity associated to PPXU
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVPTPPKF
alarmSeverityPtppkf
This attribute indicates the alarm severity associated to PTPPKF
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVPWRD
alarmSeverityPwrd
This attribute indicates the alarm severity associated to PWRD
equipment object.
CRITICAL
MAJOR
MINOR
MINOR
CRITICAL
MAJOR
MINOR
MAJOR


A30808-X3247-M230-6-7619

1593
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVSYNC
alarmSeveritySync
This attribute indicates the alarm severity associated to SYNC
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVSYNE
alarmSeveritySyne
This attribute indicates the alarm severity associated to SYNE
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR


1594 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALRMSEVTDPC
alarmSeverityTdpc
This attribute indicates the alarm severity associated to TDPC
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVTRAU
alarmSeverityTrau
This attribute indicates the alarm severity associated to TRAU
functional object.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVTRX
alarmSeverityTrx
This attribute indicates the alarm severity associated to TRX
functional object.
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
CRITICAL


A30808-X3247-M230-6-7619

1595
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ALRMSEVX25A
alarmSeverityX25a
This attribute indicates the alarm severity associated to X25A
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
ALRMSEVX25D
alarmSeverityX25d
This attribute indicates the alarm severity associated to X25D
equipment object.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR
CRITICAL
MAJOR
MINOR
MAJOR


1596 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
ALTH
alarmThreshold
This parameter represents the alarm threshold. Values expressed in dB.
Validity Range
Default Value
Contained in the following commands:
CREATE RFLOOP, GET RFLOOP, SET RFLOOP
AMONTH
aintTchMonitorThresholds
Default values are referred respectively to: Minor, Major and Critical.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
AMRACMRDL
aMRAveragedCMRDL
14 - 100 dB
30
This attribute indicates the A-Int Monitor Thresholds for TSLA.
The threshold is the percentage between out of service TSLA on
equipped TSLA; that is:
AMONTH = (TSLA out of service / TSLA equipped)*100
The threshold values can be assigned only when the flag attribute is
set to "enabled".
Minor Disabled 0 - 0
Enabled 1 - 100
Major Disabled 0 - 0
Enabled 1 - 100
Critical Disabled 0 - 0
Enabled 1 - 100
Enabled(30)-Enabled(60)-
Enabled(90)


A30808-X3247-M230-6-7619

1597
CML:BSC a
Id:0900d805800ceca9
This parameter defines the size of the averaging window for Codec Mode Requests
(CMR's) received from the MS during an AMR (Adaptive MultiRate) call. Parameter
settings larger than 31 are resulting in a size of 31.
In case of Satellites Links (Abis or Asub) the parameter is ignored.
Validity Range
Default Value
5 CMR
Contained in the following commands:
GET HAND, SET HAND
AMRFRC1
aMRFullRateCodec1
1 - 31 (1 CMR step size)
<NULL>
This parameter indicates the first (most robust) AMR (Adaptive Mul-
tiRate) active codec in case of Full Rate codec.
The following bit rate can be set:
RATE_01 4.75 kbit/s
RATE_02 5.15 kbit/s
RATE_03 5.90 kbit/s
RATE_04 6.70 kbit/s
RATE_05 7.40 kbit/s
RATE_06 7.95 kbit/s
RATE_07 10.2 kbit/s
RATE_08 12.2 kbit/s


1598 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
RATE_01
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRC2
aMRFullRateCodec2
This parameter indicates the second AMR (Adaptive MultiRate) active codec in case of
Full Rate codec.
For the bit rate numerical values refer to AMRFRC1 parameter.
Validity Range
Default Value
RATE_03
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>


A30808-X3247-M230-6-7619

1599
CML:BSC a
Id:0900d805800ceca9
AMRFRC3
aMRFullRateCodec3
This parameter indicates the third AMR (Adaptive MultiRate) active codec in case of Full
Rate codec.
For the bit rate numerical values refer to AMRFRC1 parameter.
Validity Range
Default Value
RATE_06
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRC4
aMRFullRateCodec4
This parameter indicates the fourth (least robust) AMR (Adaptive MultiRate) active
codec in case of Full Rate codec.
For the bit rate numerical values refer to AMRFRC1 parameter.
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>


1600 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
RATE_08
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRIC
aMRFullRateInitialCodec
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>
This parameter defines the Initial Codec Mode, i.e. the Full Rate
active codec mode which must be sent at first during a call when the
frequency hopping is enabled.
START_MODE_FR value depends on the number of codec modes
contained in the Active Codec Set, which is equal to the number of
AMRFRCi attributes set at a value different from NULL.
The rule is the following.
If the Active Codec Set contains:
1 mode this is the Initial Codec Mode;
2 or 3 modes the Initial Codec Mode is the most robust
mode of the set (i.e. the one with lowest
bit rate);
4 modes the Initial Codec Mode is the second most
robust mode of the set (i.e. the one with
second lowest bit rate).
CODEC_MODE_0i value corresponds to AMRFRCi value.


A30808-X3247-M230-6-7619

1601
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
START_MODE_FR
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRLLCOM
aMRFullRateLayerListComplementary
This parameter defines the list of TRX layers assigned to speech call applying AMR FR
codec in the inner/near area of dual area cell (extended, concentric, single/dual band),
or in the complementary band of a dual band standard cell. The TRX layers are specified
in the list in a decreasing priority order.
START_MODE_FR
CODEC_MODE_01
CODEC_MODE_02
CODEC_MODE_03
CODEC_MODE_04
<NULL>


1602 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRLLPRM
aMRFullRateLayerListPrimary
This parameter defines the list of TRX layers assigned to speech call applying AMR FR
codec in a single band standard cell, or in the complete/far area of a dual area cell
(extended, concentric single/dual band), or in the BCCH band of a dual band standard
cell. The TRX layers are specified in the list in a decreasing priority order.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


A30808-X3247-M230-6-7619

1603
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRTH12
aMRFullRateThresholds12
This parameter defines the couple "threshold-hysteresis" related to the active codecs
specified in the AMRFRC1 and AMRFRC2 attributes in case of Full Rate codec.
The numerical range for the threshold is 0 to 31.5 dB and for
hysteresis is 0 to 7.5 dB.
Validity Range
Default Value
Threshold : 7 [3.5 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>


1604 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
AMRFRTH23
aMRFullRateThresholds23
This parameter defines the couple "threshold-hysteresis" related to the active codecs
specified in the AMRFRC2 and AMRFRC3 attributes in case of Full Rate codec when
the frequency hopping is enabled.
The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB.
Validity Range
Default Value
Threshold : 12 [6.0 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRFRTH34
aMRFullRateThresholds34
This parameter defines the couple "threshold-hysteresis" related to the active codecs
specified in the AMRFRC3 and AMRFRC4 attributes in case of Full Rate codec when
the frequency hopping is enabled.
The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB.
Validity Range
Default Value
Threshold : 23 [11.5 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRC1
aMRHalfRateCodec1
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>
This attribute indicates the first (most robust) AMR active codec in
case of Half Rate codec. The following bit rate can be set:


A30808-X3247-M230-6-7619

1605
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
RATE_01
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRC2
aMRHalfRateCodec2
This attribute indicates the second AMR active codec in case of Half Rate codec. For
the bit rate numerical values refer to AMRHRC1 parameter.
Validity Range
Default Value
RATE_02
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRC3
aMRHalfRateCodec3
RATE_01 4.75 kbit/s
RATE_02 5.15 kbit/s
RATE_03 5.90 kbit/s
RATE_04 6.70 kbit/s
RATE_05 7.40 kbit/s
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>


1606 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
This attribute indicates the third AMR active codec in case of Half Rate codec. For the
bit rate numerical values refer to AMRHRC1 parameter.
Validity Range
Default Value
RATE_03
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRC4
aMRHalfRateCodec4
This attribute indicates the fourth (least robust) AMR active codec in case of Half Rate
codec. For the bit rate numerical values refer to AMRHRC1 parameter.
Validity Range
Default Value
RATE_04
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRIC
aMRHRInitialCodec
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>
This parameter defines the Initial Codec Mode, i.e. the Half Rate
active codec mode which must be sent at first during a call when the
frequency hopping is enabled.


A30808-X3247-M230-6-7619

1607
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
START_MODE_HR
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRLLCOM
aMRHalfRateLayerListComplementary
This parameter defines the list of TRX layers assigned to speech call applying AMR HR
codec in the inner/near area of dual area cell (extended, concentric, single/dual band),
or in the complementary band of a dual band standard cell. The TRX layers are specified
in the list in a decreasing priority order.
START_MODE_HR value depends on the number of codec modes
contained in the Active Codec Set, which is equal to the number of
AMRHRCi attributes set at a value different from NULL.
The rule is the following.
If the Active Codec Set contains:
1 mode this is the Initial Codec Mode;
2 or 3 modes the Initial Codec Mode is the most robust
mode of the set (i.e. the one with lowest bit
rate);
4 modes the Initial Codec Mode is the second most
robust mode of the set (i.e. the one with
second lowest bit rate).
CODEC_MODE_0i value corresponds to AMRHRCi value.
START_MODE_HR
CODEC_MODE_01
CODEC_MODE_02
CODEC_MODE_03
CODEC_MODE_04
<NULL>


1608 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRLLPRM
aMRHalfRateLayerListPrimary
This parameter defines the list of TRX layers assigned to speech call applying AMR HR
codec in a single band standard cell, or in the complete/far area of a dual area cell
(extended, concentric single/dual band), or in the BCCH band of a dual band standard
cell. The TRX layers are specified in the list in a decreasing priority order.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


A30808-X3247-M230-6-7619

1609
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRTH12
aMRHalfRateThresholds12
This attribute indicates the couple "threshold-hysteresis" related to the active codecs
specified in the AMRHRC1 and AMRHRC2 attributes in case of Half Rate codec when
the frequency hopping is enabled.
Validity Range
Default Value
Threshold : 19 [9.5 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>


1610 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
AMRHRTH23
aMRHalfRateThresholds23
This attribute indicates the couple "threshold-hysteresis" related to the active codecs
specified in the AMRHRC2 and AMRHRC3 attributes in case of Half Rate codec when
the frequency hopping is enabled.
Validity Range
Default Value
Threshold : 24 [12.0 dB]
Hysteresis: 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRHRTH34
aMRHalfRateThresholds34
This attribute indicates the couple "threshold-hysteresis" related to the active codecs
specified in the AMRHRC3 and AMRHRC4 attributes in case of Half Rate codec when
the frequency hopping is enabled.
Validity Range
Default Value
Threshold : 26 [13.0 dB for BTSP family and
<NULL> for BTSE family]
Hysteresis : 2 [2.0dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
AMRLKAT
aMRLinkAdapTuning
This parameter is used by the AMR Uplink Codec Mode Adaptation in the BTS. It tunes
the transition between codec modes determined by internal thresholds. A value higher
than the default shifts the transition towards higher carrier-to-interferer ratios. A value
lower than the default has the opposite effect. Adaptation of AMR Half Rate and AMR
Full Rate is affected simultaneously. All possible transitions between modes are simul-
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>


A30808-X3247-M230-6-7619

1611
CML:BSC a
Id:0900d805800ceca9
taneously shifted by the same amount. The default value is the optimum setting and
normally requires no modification.
Validity Range
Default Value
100 [0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ANTHOPMOD
antennaHoppingMode
This parameter specifies whether the BCCH transceiver has to be included in the
hopping sequence for Antenna Hopping or not.
Validity Range
Default Value
NOBCCHTRX
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ANTHOPP
antennaHoppingPeriod
0 - 200 (0.1 dB step size)
where: 0 = -10 dB .. 200 = +10 dB
<NULL>
ALLTRX
NOBCCHTRX
<NULL>
This parameter is used for Antenna Hopping and specifies how
many frames are transmitted over each antenna before the next one
is used to send the frames.
The meaning of the values is the following:
ALL Antenna Hopping is performed every frame;
SECOND Antenna Hopping is performed every two
frames;
FOURTH Antenna Hopping is performed every four
frames;


1612 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
SECOND
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
APLESSNBSC
applPartSSNLCSEBSC
This parameter defines the Subsystem Number for BSSAP-LE (Base Station System
Application Part-LCS Extension) for BSC point of view.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
APLESSNSMLC
applPartSSNLESMLC
This parameter defines the Subsystem Number for BSSAP-LE (Base Station System
Application Part-LCS Extension) for SMLC (Serving Mobile Location Center) point of
view.
SEQ_445 the 4-4-5 mode is set, which means that
each 3rd Hopping step the period is
extended from 4 to 5 frames.
ALL
SECOND
FOURTH
SEQ_445
<NULL>
15 - 255
250


A30808-X3247-M230-6-7619

1613
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
ASCILLPRM
asciLayerListPrimary
This parameter defines the list of TRX layers assigned to ASCI VBS/VGCS services in
a single band standard cell, or in the complete/far area of a dual area cell (extended,
concentric single/dual band), or in the BCCH band of a dual band standard cell. The
TRX layers are specified in the list in a decreasing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ASCIONECHMDL
asciOneChannelModel
15 - 255
252
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


1614 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
This attribute will assume two values: FALSE that means 1.5 channel mode and TRUE
that means 1 channel mode. The option TRUE allows to use the uplink of the common
group call channel by the subsequent talker in cae of Voice Group Call Services(1
channel model for VGCS).
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ASCISER
advancedSpeechCallItemsService
This parameter is used to indicate whether the advancedSpeechCallItemsService is
enabled in a cell or not. If the value ASCI_ENABLED is set, both VBS and VGCS
services are enabled.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ASCIULR
asciUplinkReply
This parameter is used to enable or disable the uplink reply
procedure for both VGCS and VBS.
If the ASCISER is disabled the uplink reply procedure must be disabled; if ASCISER is
enabled the uplink reply procedure can be enabled or disabled.
TRUE
FALSE
FALSE
ASCI_DISABLED
ASCI_ENABLED
ASCI_DISABLED


A30808-X3247-M230-6-7619

1615
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
ULRDISABLE
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ASEV
associatedSeverity
This attribute represents the severity associated to the environmental event.
Validity Range
Default Value
Contained in the following commands:
CREATE ENVA, GET ENVA, SET ENVA
ASMONTH
aintSs7MonitorThresholds
Default values are referred respectively to: Minor, Major and Critical.
ULRDISABLE
VBSENABLE
VGCSENABLE
VBC_VGCSENABLE
<NULL>
CRITICAL
MAJOR
MINOR
CRITICAL
This attribute indicates the A-Int Monitor Thresholds for SS7
channels. The threshold is the percentage between out of service
SS7L on equipped SS7L; that is:
ASMONTH = (SS7L out of service / SS7L equipped)*100).
The threshold values can be assigned only when the flag attribute is
set to "enabled".


1616 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ASSFAIR
assignmentFailureRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
ASSLAPD
associatedLapd
This attribute specifies the SUBTSLB 'control LAPD'.
Validity Range
It is defined as a pathname. Accepted value are: LPDLM
(BTSM:btsmn/LPDLM:lpdlmn).
Default Value
None.
Contained in the following commands:
CREATE SUBTSLB, GET SUBTSLB
Minor Disabled 0 - 0
Enabled 1 - 100
Major Disabled 0 - 0
Enabled 1 - 100
Critical Disabled 0 - 0
Enabled 1 - 100
Enabled(30)-Enabled(60)-
Enabled(90)
Pathname
<NULL>
NULL


A30808-X3247-M230-6-7619

1617
CML:BSC a
Id:0900d805800ceca9
ASTRING
associatedString
This attribute represents further information related to environmental alarm.
Validity Range
Default Value
Contained in the following commands:
CREATE ENVA, GET ENVA, SET ENVA
ASUBCH
asubChannel
The ASUBCH (A-sub Channel) parameter identifies the A-Sub signal channel used for
O&M messages. It consists of three fields: pcmsNumber, Tsl (Timeslot) and Ssl (Sub-
Slot).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE LPDLS, GET LPDLS
ASUBISAT
asubInterfaceOnSatellited
This attribute indicates whether the LAPD link on the Asub interface is satellited or ter-
restrial.
0..26 characters string
""
PcmsNumber 0 - 47
Tsl 1 - 31 1..31 for PCM30 line
1..24 for PCM24 line
Ssl 0 - 3


1618 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800ceca9
a
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ATIME<N>
accumulationTime<n>
Four parameters are provided (<n> from 1 to 4).
This parameter defines the daily time intervals (first, second, etc.) of observation of a
SCA object (accumulation periods); we can have up to 4 accumulation periods a day
and the accumulation time periods must not have intersections.
Each parameter consists of two fields: startTime (startHour and startMinute) and
stopTime (stopHour and stopMinute).
For ATIME2 to ATIME4 also the value <NULL> can be selected by the user.
Validity Range
Default Value
Contained in the following commands:
CREATE SCA, GET SCA, SET SCA
ATT<n>
attribute1
Eigth parameters are provided (<n> from 1 to 8). Each parameter consists of two fields:
- the real acronym, given as a string
- the attribute value (optional), given in a type driven choice
TRUE
FALSE
FALSE
StartTime Hour 6 - 23
Minute 0 - 59
StopTime Hour 6 - 23
Minute 0 - 59
(6-0)-(23-59)


A30808-X3247-M230-6-7619

1619
CML:BSC a
Id:0900d805800ceca9
Validity Range
Default Value
None.
Contained in the following commands:
BRIDGE BSC
AUTOREP
autoReport
This parameter allows the user to enable or disable the automatic file upload. This oper-
ation can be activated for no more than 20 cells.
Validity Range
Default Value
Contained in the following commands:
CREATE RFLOOP, GET RFLOOP, SET RFLOOP
acronym 1..15 characters
string
value null 0 - 0
integer 0 - 12345678
boolean TRUE
FALSE
string 1..100 charac-
ters string
pathName Pathname
TRUE
FALSE
FALSE


1620 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
b
BAF
baf
Validity Range
Default Value
0
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
BAND
band
This parameter defines the band of frequencies observed by a SCA instance.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE SCA, GET SCA
BANDOFHYS
bandWidthOfHysteresis
This parameter defines the bandwidth of hysteresis. The value of this parameter must
be lower than the ALTH parameter value. Values expressed in dB.
Defines frame alignment bits, called spare bits a4-a7, that can be set
by an operator.
This attribute is only significant for PCM30 lines and not for PCM24.
0 - 255
<NULL>
P
E
DCS
GSM_R
PCS
GSM850


A30808-X3247-M230-6-7619

1621
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
CREATE RFLOOP, GET RFLOOP, SET RFLOOP
BARINSYSINF10
barredInSysInfo10
In Sysinfo10 it is possible to indicate a cell as barred. If barred in Sysinfo10 the MS will
skip this cell as a possible target for cell reselection.
This opportunity can be used to avoid the cell reselection of a cell belonging to a different
LAC in group receive mode while still maintaining the possibility to select such a cell both
in idle mode and as HO target. The parameter BARINSYSINF10 is used to configure a
certain cell as barred in Sysinfo10.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
BAUDRATE
baudRate
It is necessary with clock equal to INTERNAL; when clock is equal to EXTERNAL, this
parameter must be skipped.
0 - 100
25
TRUE
FALSE
FALSE


1622 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
CREATE X25D, GET X25D
BCCHFREQ
bcchFrequency
This attribute defines the absolute radio frequency channel number of the BCCH
channel.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
BCCHTRX
bcchTransceiver
This read-only parameter is equal to TRUE when the TRX is the broadcast one
(BCCHTRX), otherwise is equal to FALSE.
Validity Range
Default Value
None.
Contained in the following commands:
GET TRX
BAUD_4800
BAUD_9600
BAUD_19200
BAUD_38400
BAUD_64000
BAUD_64000
0 - 1023 For the values see the complete look-up tables in
Appendix B: Group 1.
TRUE
FALSE


A30808-X3247-M230-6-7619

1623
CML:BSC b
Id:0900d805800cecac
BCGRTODIFFSERV
backgroundToDiffserv
This parameter represents the mapping between background class and DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
BCGRWEI
backgroundWeight
This parameter represents the weight for background class, (scheduling priority 4).
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BCKUPESU
backupESU
This read-only parameter indicates which software ESU (Executable Software Unit) will
be loaded at next system restart.
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCOSUDB, GET BSCOSUSW, GET BTSMOSUSW, GET TRAUOSUSW
BEPAVGP
bitErrorProbabilityAveragePeriod
0 - 63
0
1 - 32
1
<ANY>
<NULL>


1624 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
This parameter is sent on system information message to provide MS with
BEP_PERIOD value, in order to filter BEP values as written in GSM 05.08.
Validity Range
Default Value
5
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BEPFIDLWEI
bestEffortPFIDLWeight
This parameter represents the weight for predefined PFI best effort in DL.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BEPFITODIFFSERV
bestEffortPFIToDiffserv
This parameter represents the mapping between predefined PFI best effort parameter
and DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
BER
ber
Bit Error Rate.
0 - 15
<NULL>
1 - 32
1
0 - 63
0


A30808-X3247-M230-6-7619

1625
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
BHOFOT
backHoForbiddenTimer
This parameter is used to prevent back handover towards the originating cell for Traffic
and Power Budget reasons when the previous handover was performed for traffic
reasons. Values are expressed in seconds.
Validity Range
Default Value
100
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
BLERAVEDL
blockErrorRateAveragingPeriodDownlink
This parameter allows to define the averaging period (TAVG) for BLER calculation for a
Downlink TBF. The value is expressed in unit of 20 ms. The averaging period depends
also on the number of radio timeslots (#TS) allocated to a radio timeslots, according to
the formula: TAVG = BLERAVEDL / #TS.
E10_3
E10_4
E10_5
E10_3
1 - 120
<NULL>


1626 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BLERAVEUL
blockErrorRateAveragingPeriodUplink
This parameter allows to define the averaging period (TAVG) for BLER calculation for
an Uplink TBF. The value is expressed in unit of 20 ms. The averaging period depends
also on the number of radio timeslots (#TS) allocated to a radio timeslots, according to
the formula: TAVG = BLERAVEUL / #TS.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
UNIT025
UNIT050
UNIT100
UNIT150
UNIT200
UNIT250
UNIT300
UNIT350
UNIT400
UNIT200
UNIT025
UNIT050
UNIT100
UNIT150
UNIT200
UNIT250
UNIT300
UNIT350
UNIT400
UNIT100


A30808-X3247-M230-6-7619

1627
CML:BSC b
Id:0900d805800cecac
BMONTH
bintChanMonitorThresholds
Default values are referred respectively to: Minor, Major and Critical.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
BNDWIDTDD
bandwidthTdd
This attribute defines the bandwidth of the TDD cell.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTTDD, GET TGTTDD, SET TGTTDD
This attribute indicates the B-Int Monitor Thresholds for traffic
channels. It represents the percentage of out of service channels on
equipped traffic channels.
The threshold values can be assigned only when the previous
attribute is "enabled".
Minor Disabled 0 - 0
Enabled 1 - 100
Major Disabled 0 - 0
Enabled 1 - 100
Critical Disabled 0 - 0
Enabled 1 - 100
Enabled(30)-Enabled(60)-
Enabled(90)
MCPS384
MCPS128


1628 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
BPAGCHR
bsPagchBlocksReserved
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BPRACHR
bsPrachBlocksReserved
This parameter indicates the number of blocks reserved for PAGCH,
PDTCH and PACCH for the 52 frames multiframe case (see GSM
05.02).
The parameter is coded according to the following table:
0 0 0 0 0 blocks reserved for PAGCH, PDTCH and PACCH;
0 0 0 1 1 blocks reserved for PAGCH, PDTCH and PACCH;
....; ....;
1 1 0 0 12 blocks reserved for PAGCH, PDTCH and PACCH.
This parameter also determines the number of mobile stations allo-
cable on PBCCH and PCCCH channels for packet data traffic both
for uplink and downlink directions (it will be computed in a propor-
tional way based on the number of free blocks in the control chan-
nel).
0 - 12
7
This parameter indicates the number of blocks reserved in a fixed
way to the PRACH channel on any PDCH carrying PCCCH and
PBCCH (Only for 52 type PCCCH) (see GSM 05.02). The parameter
is coded according to the following table:
0 0 0 0 No blocks reserved for PRACH
0 0 0 1 Block B0 reserved for PRACH
0 0 1 0 Blocks B0, B6 reserved for PRACH
0 0 1 1 Blocks B0, B6, B3 reserved for PRACH
0 1 0 0 Blocks B0, B6, B3, B9 reserved for PRACH
0 1 0 1 Blocks B0, B6, B3, B9, B1 reserved for PRACH
0 1 1 0 Blocks B0, B6, B3, B9, B1, B7 reserved for PRACH
0 1 1 1 Blocks B0, B6, B3, B9, B1, B7, B4 reserved for
PRACH


A30808-X3247-M230-6-7619

1629
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BSCDVMA
bsCountdownValueMax
This parameter represents the value of timer T3198, at MS side, expressed in number
of RLC blocks.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BSCOVLH
bscOvlHand
This attribute allows a managing system to enable or disable the BSC Overload Han-
dling.
1 0 0 0 Blocks B0, B6, B3, B9, B1, B7, B4, B10 reserved for
PRACH
1 0 0 1 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2 reserved
for PRACH
1 0 1 0 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2, B8
reserved for PRACH
1 0 1 1 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2, B8, B5
reserved for PRACH
1 1 0 0 Blocks B0, B6, B3, B9, B1, B7, B4, B10, B2, B8, B5,
B11 reserved for PRACH
This parameter also determines the number of mobile stations
allocable on PBCCH and PCCCH channels for packet data traffic
both for uplink and downlink directions (it will be computed in a pro-
portional way based on the number of free blocks in the control
channel).
0 - 12
4
1 - 15
8


1630 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT1
bscTimer1
Time to receive BLOCKING ACK message.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT10
bscTimer10
TRUE
FALSE
TRUE
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 12
Note: It's recommended to set the related values of timers BSCT10,
TSYNC, TTRAU and RDLNKBTS respecting the following rule:
T10+2sec<TSYNC (BTS), TTRAU
T10+2sec<RDLNKBTSx0,480sec
If default values are set not respecting the above rule, please change
the values with SET command.
Time to receive ASSIGNMENT COMPLETE message to MS.


A30808-X3247-M230-6-7619

1631
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT11PUB
bscTimer11Public
This attribute defines the maximum allowed queueing time for assignment requests in
the Public queue.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT11WPS
bscTimer11WPS
This new attribute defines the maximum allowed queueing time for assignment requests
in the WPS queue.
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 10
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 16


1632 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT13
bscTimer13
Reset Guard period at BSS.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT17
bscTimer17
Overload timer.
tunitType HLFSEC (half second unit)
SEC5 (5-second unit)
tvalueType 0 - 254
tunitType HLFSEC
tvalueType 56
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 50


A30808-X3247-M230-6-7619

1633
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT18
bscTimer18
Overload timer.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT19
bscTimer19
Time to receive RESET CIRCUIT ACKNOWLEDGE at the BSS.
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 20
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 60


1634 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT20
bscTimer20
Time to receive CIRCUIT GROUP BLOCKING ACKNOWLEDGE.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT3
bscTimer3
RESOURCE INDICATION message sending periodicity.
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 12
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 12


A30808-X3247-M230-6-7619

1635
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT3121
bscTimer3121
This timer is started by the sending of an INTER SYSTEM TO UTRAN HANDOVER
COMMAND message and is normally stopped when the CLEAR COMMAND message
with cause "handover successful" is received by BSC.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT4
bscTimer4
Time to return RESET ACK message.
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 50
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 10


1636 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT7
bscTimer7
HANDOVER REQUIRED message sending periodicity.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCT8
bscTimer8
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 60
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 6
Note: It's recommended to set the related values of timers BSCT8,
TSYNC, TTRAU and RDLNKBTS respecting the following rule:
T8+2sec<TSYNC(BTS), TTRAU
T8+2sec<RDLNKBTSx0,480sec
If default values are set not respecting the above rule, please change
the values with SET command.
Time to receive HANDOVER COMPLETE message.


A30808-X3247-M230-6-7619

1637
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCTQHOPUB
bscTimerQueueHoPublic
This attribute defines the maximum allowed queueing time for handover requests in the
Public queue.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSCTQHOWPS
bscTimerQueueHoWPS
This attribute defines the maximum allowed queueing time for handover requests in the
WPS queue.
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 10
TunitType HLFSEC (half second unit)
SEC5 (5-second unit)
TvalueType 0 - 254
TunitType HLFSEC
TvalueType 20


1638 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BSIC
bsIdentityCode
This parameter represents the Base Station Identity Code and it consists of two fields:
NCC (Network Colour Code) and BCC (BS Colour Code).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
BSMONTH
bintSignChanMonitorThresholds
This attribute indicates the B-Int Monitor Thresholds for signalling channels. It repre-
sents the percentage of out of service signalling channels on equipped signalling chan-
nels.
The threshold values can be assigned only when the previous attribute is "enabled".
Default values are referred respectively to: Minor, Major and Critical.
tunitType HLFSEC (half second unit)
SEC5 (5-second unit)
tvalueType 0 - 254
tunitType HLFSEC
tvalueType 20
Ncc 0 - 7
Bcc 0 - 7


A30808-X3247-M230-6-7619

1639
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
BSPBBLK
bsPbcchBlocks
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BSSAPSSN
bssapSsn
Minor Disabled 0 - 0
Enabled 1 - 100
Major Disabled 0 - 0
Enabled 1 - 100
Critical Disabled 0 - 0
Enabled 1 - 100
Enabled(30)-Enabled(60)-
Enabled(90)
This attribute indicates the number of blocks allocated to the PBCCH
in the multiframe. The parameter is coded according to the following
table:
0 0 Block B0 used for PBCCH;
0 1 Block B0, B6 used for PBCCH;
1 0 Block B0, B6, B3 used for PBCCH;
1 1 Block B0, B6, B3, B9 used for PBCCH.
This parameter also determines the number of mobile stations
allocable on PBCCH and PCCCH channels for packet data traffic
both for uplink and downlink directions (it will be computed in a pro-
portional way based on the number of free blocks in the control chan-
nel).
0 - 3
1


1640 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
This attribute indicates the Subsystem Number in the SCCP.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC
BTSEFAM
btseFamily
This read-only parameter defines the family of the BTSE equipment. The BTSEC is not
supported.
Validity Range
Default Value
None.
Contained in the following commands:
GET BTSM
BTSHSCSD
btsHSCSD
This attribute indicates whether HSCSD service is activated in the cell or not.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
15 - 255
254
BTSE
BTSEP
BTSEPICO
BTSEEM
BTSEC
BTSEXS
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1641
CML:BSC b
Id:0900d805800cecac
BTSOVLH
btsOvlHand
This attribute allows a managing system to enable or disable the BTS Overload
Handling by BSC.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
BULKDCONF
bulkDelayConfiguration
This attribute is used for the default configuration of terrestrial link. The Automatic Link
Detection monitorizes two default windows, terrestrial (160-260 ms) and satellite
window (650-750 ms), until one of two links is detected. The manual configuration is a
particular case of automatic link working where the two windows are adjacent and the
operator can insert the lower limit of the first window (bulk delay).
TRUE
FALSE
TRUE


1642 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
DELAY_0_ms
DELAY_10_ms
DELAY_20_ms
DELAY_30_ms
DELAY_40_ms
DELAY_50_ms
DELAY_60_ms
DELAY_70_ms
DELAY_80_ms
DELAY_90_ms
DELAY_100_ms
DELAY_110_ms
DELAY_120_ms
DELAY_130_ms
DELAY_140_ms
DELAY_150_ms
DELAY_160_ms
DELAY_170_ms
DELAY_180_ms
DELAY_190_ms
DELAY_200_ms
DELAY_210_ms
DELAY_220_ms
DELAY_230_ms
DELAY_240_ms
DELAY_250_ms
DELAY_260_ms
DELAY_270_ms
DELAY_280_ms
DELAY_290_ms
DELAY_300_ms
DELAY_310_ms
DELAY_320_ms
DELAY_330_ms
DELAY_340_ms


A30808-X3247-M230-6-7619

1643
CML:BSC b
Id:0900d805800cecac
DELAY_350_ms
DELAY_360_ms
DELAY_370_ms
DELAY_380_ms
DELAY_390_ms
DELAY_400_ms
DELAY_410_ms
DELAY_420_ms
DELAY_430_ms
DELAY_440_ms
DELAY_450_ms
DELAY_460_ms
DELAY_470_ms
DELAY_480_ms
DELAY_490_ms
DELAY_500_ms
DELAY_510_ms
DELAY_520_ms
DELAY_530_ms
DELAY_540_ms
DELAY_550_ms
DELAY_560_ms
DELAY_570_ms
DELAY_580_ms
DELAY_590_ms
DELAY_600_ms
DELAY_610_ms
DELAY_620_ms
DELAY_630_ms
DELAY_640_ms
DELAY_650_ms
DELAY_660_ms
DELAY_670_ms
DELAY_680_ms
DELAY_690_ms
DELAY_700_ms


1644 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
BURNOFFS
burstNumberOffset
This attribute is an integer that indicates an additional burst number offset of a BTS.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
BVCBHIPER
bvcBucketHighPercentage
If BVC Bucket Level is greater than BVCBHIPER * Bucket Size PCU then Bucket Con-
gestion is started.
DELAY_710_ms
DELAY_720_ms
DELAY_730_ms
DELAY_740_ms
DELAY_750_ms
AUTOMATIC_LINK_DETE
CTION
DELAY_160_ms
0 - 7
<NULL>


A30808-X3247-M230-6-7619

1645
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BVCBLPER
bvcBucketLowPercentage
If BVC Bucket Level is lower than BVCBLPER * Bucket Size PCU then Bucket Conges-
tion is finished.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BVCBMAPER
bvcBucketMaxPercentage
This attribute reduces the value of Bmax automatically computed by BSC. BSC criterion
is: (C + 1 sec.) * Rmax, where C is the timer reported in GSM 08.18 recommendation
and Rmax is the maximum rate assigned to BVC.
PER50
PER60
PER70
PER80
PER90
PER70
PER10
PER20
PER30
PER40
PER50
PER60
PER70
PER80
PER60


1646 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecac
b
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
BVCBSPPER
bvcBucketSizePcuPercentage
This attribute assigns the value of Bucket Size PCU as percentage of Bmax (twice and
so on).
PER010
PER020
PER030
PER040
PER050
PER060
PER070
PER080
PER090
PER100
PER110
PER120
PER130
PER140
PER150
PER160
PER170
PER180
PER190
PER200
PER100


A30808-X3247-M230-6-7619

1647
CML:BSC b
Id:0900d805800cecac
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PER100
PER110
PER120
PER130
PER140
PER150
PER160
PER170
PER180
PER190
PER200
PER200


1648 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
c
C31H
c31Hysteresis
This attribute indicates if the GPRS reselection hysteresis shall be applied to the C31
criterion.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
C32QUAL
c32Qualifier
If C32_QUAL is set, positive GPRS_RESELECT_OFFSET values shall only be applied
to the neighbor cell with the highest RLA value among those cells for which C32 is com-
pared.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
CACKTYP
controlAcknowledgementType
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
This parameter indicates the format of the Packet Control
Acknowledgement the MS shall transmit when polled. The meaning
of the setting values is the following:
0 Packet Control Acknowledgement format is four
access bursts


A30808-X3247-M230-6-7619

1649
CML:BSC c
Id:0900d805800cecaf
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
CALLF<NN>
cellAllocationF<nn>
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CBCLTYPE
cbclType
This read-only parameter indicates the type of CBC used.
1 Packet Control Acknowledgement format is RLC/MAC
control block
The value "0" (default value) is hardcoded in the software, so
parameter changes have no influence.
0 - 1
0
Sixty three parameters are provided (<nn> from 01 to 63).
This parameter (cell allocation) defines the set, without the Bcch Fre-
quency, of radio frequencies allocated and available to a cell.
If this attribute is used in SET command in order to delete all the fre-
quencies, it must be set only to the BCCH frequency value, skipping
all the other entries.
0 - 1023
<NULL>
NULL


1650 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
CBC_EXTERNAL
Contained in the following commands:
GET CBCL
CBCPH
CBCphase
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
CBQ
cellBarQualify
CBC_INTERNAL
CBC_EXTERNAL
This parameter defines the type of Cell Broadcast Center connected
to the BSC. The meaning of the setting values is the following:
PH1_CBC the CBC connected to the BSC is a phase 1
PH2_CBC the CBC connected to the BSC is a phase 2
To indicate that the CBC connected to the BSC does not support the
extended CBCH, the operator has to set CBCPH=PH1_CBC,
otherwise CBCPH=PH2_CBC (the CBC connected to the BSC
support the extended CBCH).
PH1_CBC
PH2_CBC
PH1_CBC
This attribute is used by the network to control mobile station GSM
Phase 2 cell selection and reselection. The meaning of the setting
values is the following:
0 high priority
1 low priority


A30808-X3247-M230-6-7619

1651
CML:BSC c
Id:0900d805800cecaf
Validity Range
Default Value
0
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
CCALL
commonCellAllocation
This attribute (co-cell allocation) defines the list of frequencies inherited from CBTS.
0 - 1
<NULL>


1652 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
0 to 63 items of
cCallF01
cCallF02
cCallF03
cCallF04
cCallF05
cCallF06
cCallF07
cCallF08
cCallF09
cCallF10
cCallF11
cCallF12
cCallF13
cCallF14
cCallF15
cCallF16
cCallF17
cCallF18
cCallF19
cCallF20
cCallF21
cCallF22
cCallF23
cCallF24
cCallF25
cCallF26
cCallF27
cCallF28
cCallF29
cCallF30
cCallF31
cCallF32
cCallF33
cCallF34


A30808-X3247-M230-6-7619

1653
CML:BSC c
Id:0900d805800cecaf
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
cCallF35
cCallF36
cCallF37
cCallF38
cCallF39
cCallF40
cCallF41
cCallF42
cCallF43
cCallF44
cCallF45
cCallF46
cCallF47
cCallF48
cCallF49
cCallF50
cCallF51
cCallF52
cCallF53
cCallF54
cCallF55
cCallF56
cCallF57
cCallF58
cCallF59
cCallF60
cCallF61
cCallF62
cCallF63
<NULL>
NULL


1654 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
CCALLF<nn>
commonCellAllocationF01
Sixty three parameters are provided (<nn> from 01 to 63).
This parameter (co-cell allocation) defines the set, of radio frequencies allocated and
available to a cell.
If this attribute is used in SET command in order to delete all the frequencies, it must be
set to <NULL>.
Validity Range
Default Value
Contained in the following commands:
CREATE CBTS, GET CBTS, SET CBTS
CCDIST
enableConCellDist
The attribute enables/disables whether the distance should also have an impact on the
intracell handover decision in addition to the
HORXLVDLI/HORXLVDLO within the concentric cell intracell handover algorithm. The
distance criteria is NOT applicable for mixed (Dual Band) cells.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
CCELL1
collocatedCell1
The attribute defines the cell belonging to the sectorized concentric cells for which it is
possible the intercell handover from inner to inner area. The attribute is meaningless if
one cell, serving or target, is not concentric.
0 - 1023
<NULL>
NULL
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1655
CML:BSC c
Id:0900d805800cecaf
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
CCELL2
collocatedCell2
The attribute defines the cell belonging to the sectorized concentric cells for which it is
possible the intercell handover from inner to inner area.The attribute is meaningless if
one cell, serving or target, is not concentric.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
CCHANTFACT
cellChangeNotificationActive
The attribute indicates whether CCN is enabled in the BSC or not. It is encoded as
follows: FALSE means that CCN is disabled in the BSC, TRUE means that CCN is
enabled in the cell.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
Pathname (example OBJ1:2/OBJ2:1/OBJ3:5)
<NULL>
NULL
Pathname (example OBJ1:2/OBJ2:1/OBJ3:5)
<NULL>
NULL
TRUE
FALSE
FALSE


1656 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
CELLBARR
cellBarred
This attribute indicates whether Mobile Station may camp on the cell. The value "TRUE"
indicates that the cell is barred and camping on the cell is forbidden.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
CELLGLID
cellGlobalIdentity
Validity Range
Default Value
None.
TRUE
FALSE
FALSE
Cell Global Identity. This attribute contains the Cell Identification (CI)
and the Location Area Id of the cell.
A Location Area Id is unique within a GSM PLMN; a Cell Identifica-
tion is unique within a location area.
It consists of four fields:
MCC Mobile Country Code
MNC Mobile Network Code
LAC Location Area Code
Cl Cell Identity
MCC 3..3 characters
string
(the three characters are mandatory)
MNC 2..3 characters
string
(at least the first two characters are set)
LAC 0 - 65535
CI 0 - 65535


A30808-X3247-M230-6-7619

1657
CML:BSC c
Id:0900d805800cecaf
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, CREATE TGTFDD, CREATE TGTTDD, GET
BTS, GET TGTBTS, GET TGTFDD, GET TGTTDD, SET BTS, SET TGTBTS, SET
TGTFDD, SET TGTTDD
CELLRESH
cellReselectHysteresis
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
CELLTYP
cellType
It specifies the type of the cell.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CFS
ctrFileSize
This attribute identifies the maximum size (in Mbytes) for each CTR log file.
The cellReselectHysteresis attribute indicates the value of the
received RF power level hysteresis required for cell reselection.
This parameter range is from 0 to 14 dB at steps of 2 dB and is coded
as an integer number in the range 0 to 7.
0 - 7 (2 dB step size)
2
STDCELL ("standard" cell - max MS distance : 35km)
EXTCELL ("extended" cell - max MS distance : 100 km)
DBSTDCELL ("dual band standard" cell)


1658 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
CHPOOLTYP
channelPoolType
This parameter defines the pool type.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CHAN, GET CHAN, SET CHAN
CHTYPE
channelCombination
The CBCH channel is the subslot number 2 (D2) of both SDCCH/8 and SDCCH/4.
where:
TCH Traffic Channel
FACCH Fast Associated Control Channel
/H Half Rate
/F Full Rate
SACCH Slow Associated Control Channel
SDCCH Standalone Dedicated Control Channel
1 - 12
1
TCHSDPOOL
TCHPOOL
SDCCHPOOL
<NULL>
This attribute defines the logical channel combination mapped onto
the physical channel (timeslot).
The following are the permitted ways by which the channels can be
combined onto basic physical channels (numbers appearing in
brackets after channel designations indicate sub-channel numbers;
channels and sub-channels need not to be necessarily assigned).


A30808-X3247-M230-6-7619

1659
CML:BSC c
Id:0900d805800cecaf
FCCH Frequency Correction Channel
SCH Synchronization Channel
BCCH Broadcast Control Channel
CCCH Common Control Channel (CCCH = PCH + RACH + AGCH)
PCH Paging Channel
RACH Random Access Channel
AGCH Access Grant Channel
CBCH Cell Broadcast Channel
TCHSD Combined Channel
are all the logical channel types which can be mapped onto physical time slot.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CHAN, GET CHAN
CICFM
cicFormat
This attribute specifies the format for the Circuit Identity Code.
TCHFULL TCH/F + FACCH/F + SACCH/TF
SDCCH SDCCH/8 + SACCH/C8
MAINBCCH FCCH + SCH + BCCH + CCCH
MBCCHC FCCH + SCH + BCCH + CCCH +SDCCH/3 (0..2) +
SACCH/C4 (0..3)
CCCH BCCH + CCCH
SCBCH SDCCH/8(0..7) + SACCH/C8(0..7) + CBCH
BCBCH FCCH + SCH + BCCH + CCCH + SDCCH/4 + SACCH/4
+ CBCH
TCHF_HLF TCH/H(0,1) + FACCH/H(0,1) + SACCH/TH(0,1) or TCH/F
+ FACCH/F + SACCH/TF
TCHSD SDCCH/8 + SACCH/8 + TCH/H(0,1) + FACCH/H(0,1) +
SACCH/TH(0,1) or TCH/F + FACCH/F + SACCH/F


1660 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
CID
cellIdentity
This attribute identifies the cell which a trace shall be started in. It consists of a sequence
of two fields: the first field represents the btsm number, the second field represents the
bts relative number.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED, UPLCELLTR CTRCO
CITASUP
cellIdTimeAdvSupport
This parameter allows to enable/disable the location service for mobiles in idle mode
(e.g. emergency call).
When this parameter is TRUE the complete Layer 3 Information contains the APDU IE
with inside the new BBSLAP TA Layer3 message.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NOTSTRUCT
GSM
GSM
Pathname (example OBJ1:2/OBJ2:1)
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1661
CML:BSC c
Id:0900d805800cecaf
CLEAR
clear
This attribute overrides output file or appends to it.
Validity Range
Default Value
None.
Contained in the following commands:
SET LMT-INTERNAL
CLOCK
clock
It indicates if the used clock is internal to the IXLT card or coming from somewhere else.
Validity Range
Default Value
Contained in the following commands:
CREATE X25D, GET X25D
CLSETFAIR
callSetupFailureRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
NO
YES
INTERNAL
EXTERNAL
EXTERNAL
Pathname
<NULL>
NULL


1662 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
CMOBALLOC
commonMobileAllocation
A list of absolute frequencies used in hopping sequence: 63 frequencies at max.


A30808-X3247-M230-6-7619

1663
CML:BSC c
Id:0900d805800cecaf
Validity Range
1 to 63 items of
cCallF01
cCallF02
cCallF03
cCallF04
cCallF05
cCallF06
cCallF07
cCallF08
cCallF09
cCallF10
cCallF11
cCallF12
cCallF13
cCallF14
cCallF15
cCallF16
cCallF17
cCallF18
cCallF19
cCallF20
cCallF21
cCallF22
cCallF23
cCallF24
cCallF25
cCallF26
cCallF27
cCallF28
cCallF29
cCallF30
cCallF31
cCallF32
cCallF33
cCallF34


1664 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Default Value
None.
Contained in the following commands:
CREATE CFHSY, GET CFHSY, SET CFHSY
cCallF35
cCallF36
cCallF37
cCallF38
cCallF39
cCallF40
cCallF41
cCallF42
cCallF43
cCallF44
cCallF45
cCallF46
cCallF47
cCallF48
cCallF49
cCallF50
cCallF51
cCallF52
cCallF53
cCallF54
cCallF55
cCallF56
cCallF57
cCallF58
cCallF59
cCallF60
cCallF61
cCallF62
cCallF63


A30808-X3247-M230-6-7619

1665
CML:BSC c
Id:0900d805800cecaf
CODE
code
Validity Range
Default Value
HDB3
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
CONCELL
concentricCell
This attribute is a flag defining if the cell is concentric (TRUE) or not (FALSE).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CONGTH
congThreshold
The congestion control threshold determines the percentage of transmit buffers used, at
which layer 2 requests load reduction measures from layer3 or subsequently discards
messages (not applicable).
This field selects the line code to be provided on the line.
Note: for a PCM24 line the attribute value is meaningless because
the B8ZS line code is used.
AMI
HDB3
<NULL>
TRUE
FALSE
FALSE


1666 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
CPCUN
commonPCUNumber
This mandatory attribute represents the Common PCU the PCU refers to.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, CREATE PTPPKF, GET PCU, GET PTPPKF, SET PCU, SET
PTPPKF
CRC
crc
By selecting the "TRUE" option, the CRC-4 signal handling for a PCM30 line, or the
CRC-6 signal handling for a PCM24 line is enabled on the 2 Mbits/s signal.
Validity Range
Default Value
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
CREALL
callReestablishmentAllowed
This attribute indicates whether call re-establishment is allowed in the cell.
0 - 6
0
0 - 11
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1667
CML:BSC c
Id:0900d805800cecaf
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CRESELTRHINP
cellReselectionThresholdInput
This parameter defines the congestion threshold above which a gprs mobile is not let to
enter this adjacent cell.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
CRESELTRHSOUT
cellReselectionThresholdOutput
This parameter defines the percentage of "occupation" threshold : when the number of
active gprs mobile is over this value , the network controlled cell reselection procedure
can order gprs mobiles to reselect another cell until number of gprs active mobile is
again under the threshold.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
CRESOFF
cellReselectionOffset
This attribute applies an offset to the C2 reselection criterion.
ALLOWED
NOTALLOWED
NOTALLOWED
0 - 85 (step 1)
75
50 - 100 (step 1)
85


1668 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
1 [2 dB]
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
CRESPARI
cellReselectionParamInd
This attribute indicates the presence of C2 cell reselection
parameters; the "1" value means "parameters present".
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
CRTSWDLLCOM
circuitSwitchedDataLayerListComp
This parameter defines the list of TRX layers assigned to Circuit switched single slot
data call in the inner/near area of dual area cell (extended, concentric single/dual band),
or in the complementary band of a dual band standard cell. The TRX layers are specified
in the list in a decreasing priority order.
0 - 63 (2 dB step size)
<NULL>
0 - 1
1


A30808-X3247-M230-6-7619

1669
CML:BSC c
Id:0900d805800cecaf
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CRTSWDLLPRM
circuitSwitchedDataLayerListPrimary
This parameter defines the list of TRX layers assigned to Circuit switched single slot
data call in a single band standard cell, or in the complete/far area of a dual area cell
(extended, concentric single/dual band), or in the BCCH band of a dual band standard
cell. The TRX layers are specified in the list in a decreasing priority order.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


1670 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CRTSWSPELLCOM
circuitSwitchedSpeechLLComp
This parameter defines the list of TRX layers assigned to speech call applying EFR-FR-
HR codec in the inner/near area of dual area cell (extended, concentric, single/dual
band), or in the complementary band of a dual band standard cell. The TRX layers are
specified in the list in a decreasing priority order.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


A30808-X3247-M230-6-7619

1671
CML:BSC c
Id:0900d805800cecaf
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CRTSWSPELLPRM
circuitSwitchedSpeechLayerListPrimary
This parameter defines the list of TRX layers assigned to speech call applying EFR-FR-
HR codec in a single band standard cell, or in the complete/far area of a dual area cell
(extended, concentric single/dual band), or in the BCCH band of a dual band standard
cell. The TRX layers are specified in the list in a decreasing priority order.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


1672 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecaf
c
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CSCE
cellScenario
This parameter defines the propagation of a cell covered by a given BTS.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
CSCH3CSCH4SUP
codingScheme3CodingScheme4Support
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL
URBAN
SUBURBAN
RURAL_QUASI_OPEN
RURAL_OPEN
URBAN


A30808-X3247-M230-6-7619

1673
CML:BSC c
Id:0900d805800cecaf
This parameter enables/disables the feature CS3/CS4. In case of BSC object it
enables/disables the feature at BSC level. In case of PTPPKF object it enables/disables
the feature at PTPPKF level.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET BSC, GET PTPPKF, SET BSC, SET PTPPKF
CUCONF
carrierUnitConfiguration
This parameter should be set in case of a cell with an inhomogeneous carrier unit con-
figuration. It ensures that the maximum output power difference between the carrier
units is below 2 dB.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TRUE
FALSE
FALSE
cu_flexcu_bs82II this value has to be set if the cell is served by a BS82II
and has an inhomogeneous carrier unit configuration with
FlexCU and CU/ECU/GCU.
cu_ecu_dcspcs this value has to be set if the cell has an inhomogeneous
carrier unit configuration with old 1800/1900 MHz CUs
(45.3 dBm output power) and ECU V2/3/3a of the same
frequency band.
homogeneous this value has to be set if the carrier unit configuration is
homogeneous or shall be considered as homogeneous.
All carrier units use the maximum output power, which is
provided by the hardware. No adaptation of the output
power is performed. This implies, that output power differ-
ences greater than 2 dB will be accepted. This setting cor-
responds to the current system behaviour.
homogeneous


1674 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
d
DANGEROUS
dangerous
This attribute specifies whether the execution of the command has to be confirmed by
the user.
Validity Range
Default Value
None.
Contained in the following commands:
EXEC LMT-INTERNAL
DBBKPPEN
dbBackupPending
This parameter gives information if a change to the configuration file is pending.
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCOSUDB
DBVER
dbVersion
This read-only parameter defines the database version; it consists of the two parts: the
"dbStringId" (24 characters) and the "dbDate" (4 characters).
Validity Range
Default Value
None.
NO
YES
TRUE
FALSE
StringId 23..23 characters
string
Date 0 - 4294967295


A30808-X3247-M230-6-7619

1675
CML:BSC d
Id:0900d805800cecb2
Contained in the following commands:
GET BSCESUDB, GET RSUDB
DEFPOOLTYP
defPoolType
This attribute defines the type of the pool assigned to every TSLA of the given PCMA.
For pool type meaning see Appendix B: Tab. 6.14.


1676 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
Validity Range
POOL_NOTDEF
POOL_01
POOL_02
POOL_03
POOL_04
POOL_05
POOL_06
POOL_07
POOL_08
POOL_09
POOL_10
POOL_11
POOL_12
POOL_13
POOL_15
POOL_16
POOL_17
POOL_18
POOL_19
POOL_20
POOL_21
POOL_22
POOL_23
POOL_24
POOL_25
POOL_26
POOL_27
POOL_28
POOL_29
POOL_30
POOL_31
POOL_32
POOL_33
POOL_34
POOL_35


A30808-X3247-M230-6-7619

1677
CML:BSC d
Id:0900d805800cecb2
Default Value
Contained in the following commands:
CREATE PCMA, GET PCMA
DELOPT
deleteOption
This flag, if TRUE, selects that the input files must be deleted after a successful com-
pression.
Validity Range
Default Value
None.
Contained in the following commands:
FILECOM FILEHANDLER
DESTDIR
DestinationDir
This field specifies the directory name of BSC or LMT disk which the file should be trans-
ferred to, copied to or moved to.
The user can use the "Browse Dir" button to select the directory on the LMT hard-disk;
for the REMINV object commands the button is not available.
Validity Range
In commands DNLFILE SOFTWARE-MANAGEMENT, UPLBTSLOG SOFTWARE-
MANAGEMENT, UPLBTSTDLOG SOFTWARE-MANAGEMENT, UPLDFILE RSUDB,
UPLFILE SOFTWARE-MANAGEMENT, UPLTRAULOG SOFTWARE-MANAGE-
MENT, UPLALLCELLTR CTRCO, UPLCELLTR CTRCO, UPLHDCTR HDCTR,
POOL_42
POOL_43
POOL_44
POOL_45
POOL_46
POOL_47
POOL_48
POOL_NOTDEF
TRUE
FALSE


1678 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
UPLCIDF REMINV, UPLLIDF REMINV, UPLMEAS SCANCO, UPLOADREQ RFLOOP,
UPLOADREQ SCA, UPLPRLOG FILEHANDLER:
In commands UPLALLIMSITR TRACE, UPLIMSITR TRACE:
Default Value
None.
Contained in the following commands:
DNLFILE SOFTWARE-MANAGEMENT, UPLALLCELLTR CTRCO, UPLALLIMSITR
TRACE, UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG SOFTWARE-
MANAGEMENT, UPLCELLTR CTRCO, UPLCIDF REMINV, UPLDFILE RSUDB,
UPLFILE SOFTWARE-MANAGEMENT, UPLHDCTR HDCTR, UPLIMSITR TRACE,
UPLLIDF REMINV, UPLMEAS SCANCO, UPLOADREQ RFLOOP, UPLOADREQ
SCA, UPLPRLOG FILEHANDLER, UPLTRAULOG SOFTWARE-MANAGEMENT
DESTPATHNAME
destinationPathName
This parameter defines the name of the destination path.
Validity Range
Default Value
None.
Contained in the following commands:
COPY FILEHANDLER, MOVE FILEHANDLER
DGRSTRGY
downgradeStrategy
This parameter allows the user to define the resource reallocation procedure by select-
ing the preferred channel for the allocation.
1..80 characters string
0..80 characters string
1..59 characters string


A30808-X3247-M230-6-7619

1679
CML:BSC d
Id:0900d805800cecb2
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
DGRSTRGYBCNT
downgradeStrategyForBusyCounting
This parameter enables/disables the downgrade strategy taken into account for Busy
Counting.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
DIFFSERVSUP
differentServiceSupport
DiffServ is an architecture to provide different types or levels of service for network
traffic. One key characteristic of diffserv is that flows are aggregated in the network, so
that core routers only need to distinguish a comparably small number of aggregated
flows, even if those flows contain thousands or millions of individual flows. The attribute
DIFFSERVSUP define if the architecture is enabled or disabled.
HSCSD_FIRST_DOWNGR
ADE
GPRS_FIRST_DOWNGRA
DE
DOWNGRADE_HSCSD_O
NLY
DOWNGRADE_GPRS_ON
LY
NO_DOWNGRADE
GPRS_FIRST_DOWNGRA
DE
DISABLED
ENABLED
DISABLED


1680 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
DIRNAME
directoryName
This parameter defines the directory name on the BSC disk.
Validity Range
Default Value
None.
Contained in the following commands:
CREATEDIR FILEHANDLER, DIR FILEHANDLER, REMOVEDIR FILEHANDLER
DIRTCHASS
directTchAssignment
DISABLED
ENABLED
<NULL>
1..59 characters string
This attribute specifies whether the direct assignment of TCH
channel is enabled or disabled. The meaning of the setting values is
the following:
FALSE Direct TCH assignment disabled
SDCCHMS Direct TCH assignment enabled but
disabled for "answer to paging-any
channel" cause of CHANNEL
REQUIRED message (since SDC-
CHonly MS may be supported by the
network)
NOSDCCHMS Direct TCH assignment enabled also
for "answer to paging-any channel"
cause of CHANNEL REQUIRED
message (since SDCCHonly MS is not
supported by the network)


A30808-X3247-M230-6-7619

1681
CML:BSC d
Id:0900d805800cecb2
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
DISKCOPY
diskCopy
This attribute defines whether to format both copies or only one.
Validity Range
Default Value
None.
Contained in the following commands:
FORMAT DISK
DISTHO
enableDistanceHo
This attribute indicates whether handover due to distance between Mobile Station and
BTS is enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
DLAPDOVL
downlinkLapdOverload
FALSE
SDCCHMS
NOSDCCHMS
FALSE
SELECTED
BOTH_DISK
TRUE
FALSE
TRUE


1682 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
This parameter allows to enable or disable the procedure that detects the Download
Overload.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
DNLALLEXE
DnlAllExe
This parameter allows to enable or disable the download of all
executable files.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RSUSWLH
DNLBSSPFCRET
downloadBSSPFCRetries
This parameter guards the DOWNLOAD-BSS-PFC-RETRIES number.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
DNLBSSPFCT
downloadBSSPFCTimer
TRUE
FALSE
TRUE
YES
NO
1 - 5
3


A30808-X3247-M230-6-7619

1683
CML:BSC d
Id:0900d805800cecb2
This parameter represents the timer T6 and guards the DOWNLOAD-BSS-PFC proce-
dure.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
DPBGTHO
enableDelayPowerBudgetHo
This parameter indicates whether the speed sensitive handover
decision algorithm is enabled or not.
This parameter enables/disables the mobile speed sensitivity of the following han-
dovers:
- Power Budget handover from a GSM serving cell to a GSM neighbour cell
- Power Budget handover from a GSM serving cell to an UMTS neighbour cell
- Sufficient UMTS coverage handover from a GSM serving cell to an UMTS neighbour
cell.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
DRXTMA
discontinousReceptionTimerMax
2 - 99 (unit 100 ms)
50
TRUE
FALSE
FALSE
This parameter indicates the maximum value allowed for the mobile
station to request for Non-DRX mode after packet transfer mode
(upper limit for the mobile station timer T3194).
0 0 0 No Non-DRX mode after packet transfer mode
0 0 1 Max. 1 sec. Non-DRX mode after packet transfer
mode
0 1 0 Max. 2 sec.


1684 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
DTEDCE
dteDce
It indicates if IXLT works as Data Terminal Equipment or as Data Communication Equip-
ment.
Validity Range
Default Value
Contained in the following commands:
CREATE X25D, GET X25D
DTXDLFR
dTxDownLinkFullRate
The dTxDownLinkFullRate is used to indicate whether this service is enabled or not.
0 1 1 Max. 4 sec.
1 0 0 Max. 8 sec.
1 0 1 Max. 16 sec.
1 1 0 Max. 32 sec.
1 1 1 Max. 64 sec.
0 - 7
7
DTE
DCE
DTE


A30808-X3247-M230-6-7619

1685
CML:BSC d
Id:0900d805800cecb2
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
DTXDLHR
dTxDownLinkHalfRate
The dTxDownLinkHalfRate is used to indicate whether this service is enabled or not.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
DTXUL
dTxUplink
This dTxUpLink is used to indicate whether this service is enabled or not.
TRUE
FALSE
FALSE
TRUE
FALSE
<NULL>


1686 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb2
d
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
DUR
duration
Duration of measurement expressed in minutes.
Validity Range
Default Value
None.
Contained in the following commands:
FREQMEAS SYNE
MAYFSHNH (MS may use DTX for Full Rate TCHs, shall not for Half
Rate TCHs)
SHLFSHNH (MS shall use DTX for Full Rate TCHs, shall not for Half
Rate TCHs)
SHNFSHNH (MS shall not use DTX for Full Rate TCHs, shall not for
Half Rate TCHs)
MAYFMAYH (MS may use DTX for Full Rate TCHs, may use for Half
Rate TCHs)
SHLFSHLH (MS shall use DTX for Full Rate TCHs, shall for Half Rate
TCHs)
SHNFSHLH (MS shall not use DTX for Full Rate TCHs, shall for Half
Rate TCHs)
SHNFSHNH
1 - 65535


A30808-X3247-M230-6-7619

1687
CML:BSC e
Id:0900d805800cecb6
e
EAC
enableAc
This parameter indicates whether the Admission Control features is activated on cell
basis.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EADVCMPDCMHO
enableAdvComprDecomprHO
This attribute is used to enable/disable the advanced Compression/Decompression
Handover algorithm. The advanced algorithm considers the current power control situ-
ation when deciding on whether to compress (HO from FR to HR) or decompress (HO
from HR to FR) a cell. A change of the attribute becomes effective in the next SACCH
multiframe.
Validity Range
Default Value
TRUE
Contained in the following commands:
GET HAND, SET HAND
EADVCMPHOAMR
enableAdvComprHoAMR
Selection of AMR HR capable mobiles as candidate for compression handover.
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>


1688 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
TRUE
Contained in the following commands:
GET HAND, SET HAND
EADVCMPHOSC
enableAdvComprHoSC
Selection of GSM HR capable mobiles as candidate for compression handover.
Validity Range
Default Value
TRUE
Contained in the following commands:
GET HAND, SET HAND
EANTHOP
enableAntennaHopping
This parameter indicates whether Antenna Hopping is enabled or disabled for the BTS.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EARCLM
enableEarlyClassmark
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>


A30808-X3247-M230-6-7619

1689
CML:BSC e
Id:0900d805800cecb6
Flag to enable or disable the early classmark sending: that is this flag enables or
disables the Multiband Handovers (from GSM900 to DCS1800 and vice versa).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EAUTOREC
enableAutoRecovery
This attribute allows to enable or disable the Automatic Recovery.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
EBCCHTRX
egprs8pskOnBcchTrx
This parameter states if EDGE 8PSK modulation is supported on BCCH TRX.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TRUE
FALSE
TRUE
disabled
enabled
disabled
TRUE
FALSE
FALSE


1690 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
EBSPWCR
enableBSPwrCorrection
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EBSPWRC
enableBSPowerControl
This attribute enables BS Power Control and also indicates the used BS Power Control
method.
Validity Range
Default Value
ADAPTIVE : for SW version BR7.0
CLASSIC : for SW version BR6.0
Contained in the following commands:
GET PWRC, SET PWRC
EBUSYCUM
enableBusyCumulMeas
This attribute indicates whether the BS power control indicated must
be corrected. The correction of BS power control is applied in the
system information message with the following rules:
EBSPWRC EBSPWCR SYS INFO
TRUE TRUE 0
TRUE FALSE 1
FALSE TRUE 0
FALSE FALSE 0
NOTE: this parameter does not affect AMR calls.
TRUE
FALSE
TRUE
DISABLED
CLASSIC
ADAPTIVE


A30808-X3247-M230-6-7619

1691
CML:BSC e
Id:0900d805800cecb6
This parameter allows to enable or disable the Busy Cumulative Measures.
Validity Range
Default Value
Contained in the following commands:
CREATE SCA, GET SCA, SET SCA
EC
emergencyCall
This attribute determines whether emergency calls are allowed to all MSs or restricted
to MSs belonging to access classes in the range from 11 to 15. The value TRUE indi-
cates that emergency calls are restricted. The special access class 10 is used to carry
the value on the Air interface.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EDASUP
eDASupport
This attribute defines if Extended Dynamic Allocation is supported or not.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
DISABLED
ENABLED
DISABLED


1692 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
EDTMSUP
enableDTMSupport
Flag to enable/disable the DTM service.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, CREATE TGTPTPPKF, GET PTPPKF, GET TGTPTPPKF, SET
PTPPKF, SET TGTPTPPKF
EEDGE
enableEdge
This parameter allows to enable/disable EGPRS (EDGE GPRS) on cell basis.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, CREATE TGTPTPPKF, GET PTPPKF, GET TGTPTPPKF, SET
PTPPKF, SET TGTPTPPKF
EEICM
enableExtIdleChanMeas
This parameter allows to enable or disable the Extended Idle Channel Measures.
Validity Range
Default Value
Contained in the following commands:
CREATE SCA, GET SCA, SET SCA
DISABLED
ENABLED
DISABLED
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1693
CML:BSC e
Id:0900d805800cecb6
EENHDTMSUP
enabledEnhancedDTMSupport
Flag to enable/disable the "Enhanced DTM Establish" mode, as defined in 3GPP
Release 6.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
EEOTD
enableEOTD
This parameter represents the flag to enable the setting of TSC (Training Sequence
Code) equal to BCC (BS Colour Code) for all channels transmitting on BCCH frequency.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EEXCDIST
enableExcessiveDistance
The attribute indicates whether the sending of call release is enabled/disabled when the
distance between Mobile Station and BTS exceeds the excessive Distance.
DISABLED
ENABLED
DISABLED
TRUE
FALSE
FALSE


1694 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EFCRESEL
enableFastCellReselection
When this attribute is set to TRUE the BSC inserts the BCCH frequency on the BA list
sent on System Info 2. The relevant BSIC inside to System info 2 quater will broadcast
it for the specific cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EFRSUPP
enhanceFullRateSupport
This attribute indicates if the enhanced full rate is supported/allowed in the Network
Element controlled by BSC.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
EFULHO
enableFastUpLinkHo
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1695
CML:BSC e
Id:0900d805800cecb6
This parameter allows to enable or disable the Fast Uplink Handover.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET HAND, SET HAND
EGPLGPEIGHTTS
egprsPollingPeriodEightTimeSlot
This parameter suggests the polling period to be used if eight timeslots are assigned.
Validity Range
Default Value
16
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPFIVETS
egprsPollingPeriodFiveTimeSlot
This parameter suggests the polling period to be used if five timeslots are assigned.
Validity Range
Default Value
16
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPFOURTS
egprsPollingPeriodFourTimeSlot
This parameter suggests the polling period to be used if four timeslots are assigned.
TRUE
FALSE
<NULL>
8 - 64
<NULL>
8 - 64
<NULL>


1696 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
8
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPONETS
egprsPollingPeriodOneTimeSlot
This parameter suggests the polling period to be used if one timeslot is assigned.
Validity Range
Default Value
8
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPSEVENTS
egprsPollingPeriodSevenTimeSlot
This parameter suggests the polling period to be used if seven timeslots are assigned.
Validity Range
Default Value
16
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPSIXTS
egprsPollingPeriodSixTimeSlot
This parameter suggests the polling period to be used if six timeslots are assigned.
8 - 64
<NULL>
8 - 64
<NULL>
8 - 64
<NULL>


A30808-X3247-M230-6-7619

1697
CML:BSC e
Id:0900d805800cecb6
Validity Range
Default Value
16
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPTHREETS
egprsPollingPeriodThreeTimeSlot
This parameter suggests the polling period to be used if three timeslots are assigned.
Validity Range
Default Value
8
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPLGPTWOTS
egprsPollingPeriodTwoTimeSlot
This parameter suggests the polling period to be used if two timeslots are assigned.
Validity Range
Default Value
8
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGPRS
enableGprs
This parameter allows to enable/disable GPRS on cell basis.
8 - 64
<NULL>
8 - 64
<NULL>
8 - 64
<NULL>


1698 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGWSEIGHTTS
egprsWindowSizeEightTimeSlot
This parameter suggests the window size to be used if eight timeslots are assigned.
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1699
CML:BSC e
Id:0900d805800cecb6
Validity Range
Default Value
WS192
WS64
WS96
WS128
WS160
WS192
WS224
WS256
WS288
WS320
WS352
WS384
WS416
WS448
WS480
WS512
WS544
WS576
WS608
WS640
WS672
WS704
WS736
WS768
WS800
WS832
WS864
WS896
WS928
WS960
WS992
WS1024
<NULL>


1700 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGWSFIVETS
egprsWindowSizeFiveTimeSlot
This parameter suggests the window size to be used if five timeslots are assigned.
Validity Range
Default Value
WS128
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGWSFOURTS
egprsWindowSizeFourTimeSlot
This parameter suggests the window size to be used if four timeslots are assigned.
WS64
WS96
WS128
WS160
WS192
WS224
WS256
WS288
WS320
WS352
WS384
WS416
WS448
WS480
WS512
WS544
WS576
WS608
WS640
<NULL>


A30808-X3247-M230-6-7619

1701
CML:BSC e
Id:0900d805800cecb6
Validity Range
Default Value
WS96
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGWSONETS
egprsWindowSizeOneTimeSlot
This parameter suggests the window size to be used if one timeslot is assigned.
Validity Range
Default Value
WS64
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
WS64
WS96
WS128
WS160
WS192
WS224
WS256
WS288
WS320
WS352
WS384
WS416
WS448
WS480
WS512
<NULL>
WS64
WS96
WS128
WS160
WS192
<NULL>


1702 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
EGWSSEVENTS
egprsWindowSizeSevenTimeSlot
This parameter suggests the window size to be used if seven timeslots are assigned.
Validity Range
Default Value
WS160
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
WS64
WS96
WS128
WS160
WS192
WS224
WS256
WS288
WS320
WS352
WS384
WS416
WS448
WS480
WS512
WS544
WS576
WS608
WS640
WS672
WS704
WS736
WS768
WS800
WS832
WS864
WS896
<NULL>


A30808-X3247-M230-6-7619

1703
CML:BSC e
Id:0900d805800cecb6
EGWSSIXTS
egprsWindowSizeSixTimeSlot
This parameter suggests the window size to be used if six timeslots are assigned.
Validity Range
Default Value
WS160
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGWSTHREETS
egprsWindowSizeThreeTimeSlot
This parameter suggests the window size to be used if three timeslots are assigned.
WS64
WS96
WS128
WS160
WS192
WS224
WS256
WS288
WS320
WS352
WS384
WS416
WS448
WS480
WS512
WS544
WS576
WS608
WS640
WS672
WS704
WS736
WS768
<NULL>


1704 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
WS96
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EGWSTWOTS
egprsWindowSizeTwoTimeSlot
This parameter suggests the window size to be used if two timeslots are assigned.
Validity Range
Default Value
WS64
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
WS64
WS96
WS128
WS160
WS192
WS224
WS256
WS288
WS320
WS352
WS384
<NULL>
WS64
WS96
WS128
WS160
WS192
WS224
WS256
<NULL>


A30808-X3247-M230-6-7619

1705
CML:BSC e
Id:0900d805800cecb6
EHDCTR
enableHistoryOnDroppedCallTrace
This parameter represents a switch to enable or disable the feature.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EHRACT
enableHrActivation
This parameter allows to enable or disable the cell load dependent activation of half rate.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EHRACTAMR
enableHRActivationAmr
This parameter allows to enable or disable the cell load dependent activation of half rate
feature for AMR calls.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TRUE
FALSE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE


1706 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
EICNF<NN>
extIdleChanFreq<nn>
Sixty-four parameters are provided (<nn> from 1 to 64).
This parameter defines a frequency for Extended Idle Channel
Measures observation.
Validity Range
Default Value
Contained in the following commands:
CREATE SCA, GET SCA, SET SCA
EINTSITSYN
enableInterSiteSync
This parameter is a boolean that indicates whether the "Inter-Site Synchronization"
feature is activated.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
EISDCCHHO
enableInterSdcchHo
This attribute allows to enable/disable MSC-controlled SDCCH handovers (Directed
Retry). It simply prevents the sending of HO RDQ message for SDCCH connections to
the MSC.
If it is set to "disable" the BSC skips all cell identifiers of the target cell list of the intercell
HO Cond. message which belong to another BSC area. This parameter should be set
at "disable" if MSC does not support Directed Retry.
0 - 1023
<NULL>
NULL
TRUE
FALSE
<NULL>


A30808-X3247-M230-6-7619

1707
CML:BSC e
Id:0900d805800cecb6
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ELEVHOM
enableLevHOMargin
This parameter indicates if level handover margin (RXLEV_NCELL(n) > RXLEV_DL +
LHOMARGIN) is enabled or disabled.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET HAND, SET HAND
ELIMITCH
enableLimitationIntraCellHo
This attribute is used to enable/disable the 'Limitation of Intracell Handover repetition'
feature.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
ELKADPT
enableLinkAdaptation
DISABLED
ENABLED
ENABLED
TRUE
FALSE
<NULL>
TRUE
FALSE
TRUE


1708 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
This parameter enables or disables Link Adaptation algorithm. This could be useful if a
BVC has strange radio conditions or for testing purposes.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
ELLCOM
edgeLayerListComplementary
This parameter defines the list of TRX layers assigned to EDGE service in the inner/near
area of dual area cell (extended, concentric single/dual band), or in the complementary
band of a dual band standard cell. The TRX layers are specified in the list in a decreas-
ing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TRUE
FALSE
FALSE
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


A30808-X3247-M230-6-7619

1709
CML:BSC e
Id:0900d805800cecb6
ELLPRM
edgeLayerListPrimary
This parameter defines the list of TRX layers assigned to EDGE service in a single band
standard cell, or in the complete/far area of a dual area cell (extended, concentric sin-
gle/dual band), or in the BCCH band of a dual band standard cell. The TRX layers are
specified in the list in a decreasing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EMANPRESCOM
edgeMaxNumberPDCHResComplementary
The attribute defines the number of traffic channels reserved for packet connections,
exclusively on the first layer shared by EDGE and CS service in Complementary Area.
It is related to Near area in extended cell; in case of standard cell, only EMANPRESPRM
is meaningful.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


1710 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMANPRESPRM
edgeMaxNumberPDCHResPrimary
The attribute defines the number of traffic channels reserved for packet connections,
exclusively on the first layer shared by EDGE and CS service in Primary Area. It is
related to Far area in extended cell; in case of standard cell, only EMANPRESPRM is
meaningful.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMCSFAMA1DL
enMcsFamAMcs1Downlink
This attribute enables MCS belonging to Family A and MCS1 to be used, in Downlink
case.
Validity Range
Default Value
TRUE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMCSFAMAP1DL
enMcsFamAPaddingMcs1Downlink
0 - 190
0
0 - 190
0
TRUE
FALSE
<NULL>


A30808-X3247-M230-6-7619

1711
CML:BSC e
Id:0900d805800cecb6
This attribute enables MCS belonging to Family A padding and MCS1 to be used, in
Downlink case.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMCSFAMB1DL
enMcsFamBMcs1Downlink
This attribute enables MCS belonging to Family B and MCS1 to be used, in Downlink
case.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMCSFAMCDL
enMcsFamCDownlink
This attribute enables MCS belonging to Family C to be used, in Downlink Case.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>


1712 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
EMCSFAMGDL
enMcsFamGmskDownlink
This attribute enables MCS belonging to Family Gmsk to be used, in Downlink case.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFA1UNIR8PSK
enMcsFamAMcs1UplinkWoutIncrRed8Psk
This attribute enables MCS belonging to FamilyA and MCS1 to be used, if MS supports
8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work.
Validity Range
Default Value
TRUE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFAP1UNIR8PSK
enMcsFamApMcs1UplinkWoutIncrRed8Psk
This attribute enables MCS belonging to Family A padding and MCS1 to be used, if MS
supports 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does
not work.
Validity Range
Default Value
FALSE
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>


A30808-X3247-M230-6-7619

1713
CML:BSC e
Id:0900d805800cecb6
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFB1UNIR8PSK
enMcsFamBMcs1UplinkWoutIncRed8Psk
This attribute enables MCS belonging to Family B and MCS1 to be used, if MS supports
8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not work.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFCUNIR8PSK
enMcsFamCUplinkWoutIncRed8Psk
This attribute enables MCS belonging to Family C to be used, if MS supports 8PSK mod-
ulation in Uplink EGPRS TBF and Incremental Redundancy does not work.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFCUNIRGMSK
enMcsFamCUplinkWoutIncrRedGmsk
This attribute enables MCS belonging to Family C to be used, if MS does not support
8PSK modulation in Uplink EGPRS TBF and
Incremental Redundancy does not work.
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>


1714 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFGUNIR8PSK
enMcsFamGmskUplinkWoutIncRed8Psk
This attribute enables MCS belonging to Family Gmsk to be used, if MS supports 8PSK
modulation in Uplink EGPRS TBF and
Incremental Redundancy does not work.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EMFGUNIRGMSK
enMcsFamGmskUplinkWoutIncrRedGmsk
This attribute enables MCS belonging to Family Gmsk to be used, if MS does not
support 8PSK modulation in Uplink EGPRS TBF and Incremental Redundancy does not
work.
Validity Range
Default Value
TRUE
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>
TRUE
FALSE
<NULL>


A30808-X3247-M230-6-7619

1715
CML:BSC e
Id:0900d805800cecb6
EMSPWRC
enableMSPowerControl
This attribute enables MS Power Control and also indicates the used MS Power Control
method.
Validity Range
Default Value
CLASSIC : for SW version = BR6.0
ADAPTIVE : for SW version = BR7.0
Contained in the following commands:
GET PWRC, SET PWRC
EMT1
emergencyTimer1
Vaules expressed in minutes.
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
EMT2
emergencyTimer2
DISABLED
CLASSIC
ADAPTIVE
This attribute indicates the delay for the transition to the emergency
configuration in case of breakdown of the BTSE primary voltage
supply if a battery backup is available in the BTSE itself.
The transition includes the powerdown of TRX related equipment.
0 - 1400
10
This attribute indicates the delay for the transition to the zero carrier
configuration in case of breakdown of the BTSE primary voltage
supply if a battery backup is available in the BTSE itself.
The value 0 means the EMT2 is not valid, i.e. the BTSE will not
switch to a zero carrier configuration.


1716 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Values expressed in minutes.
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
ENANCD
enableNoCallDetection
This flag enables or disables the procedure of detection of "sleeping cell condition".
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ENAQUALEVHOM
enableQualityLeveHOMargin
This parameter is used to enable "Level Handover Margin for Quality Handover". It is
adjustable per cell.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
ENCALSUP
encryptionAlgorSupport
0 - 1400
10
DISABLED
ENABLED
ENABLED
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1717
CML:BSC e
Id:0900d805800cecb6
The ENCALSUP (Encryption Algorithm Supported) parameter defines the algorithms for
the radio interface ciphering supported by the BSC.
It consists of a list of 10 items (ENCALSUP1&ENCALSUP2...); for each item the field
ENCRALGOR can be set at:
NOENCR means "no ciphering"
GSMV1 represents the ciphering algorithm A5/1
GSMV2 represents the ciphering algorithm A5/2.
Default values are referred respectively to: Encalsup1 and Encalsup2.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ENDMA
enableDMA
This parameter is a boolean that indicates wheter the DMA feature is activated within
the cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, CREATE CBTS, GET BTS, GET CBTS, SET BTS, SET CBTS
ENFOIAHO
enableForcedIntracellHo
This attribute indicates whether the Forced Intracell Handover
procedure is activated or not.
1 to 10 items of
NOENCR
GSMV1
GSMV2
1 NOENCR
2 GSMV1
TRUE
FALSE
FALSE


1718 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ENFORCHO
enforceHo
This attribute enables/disables the sending of Forced HO Request messages for
running SDCCH connections (i.e. queued or not queued ASS REQ's which do not find
an empty TCH). It is used to enable/disable Directed Retry. This attribute should be set
to "disabled" if in a network the MSC which the BSS is connected to or other adjacent
BSSs do not support the prevention of "back-HO".
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ENHSCSD
enableHSCSD
This attribute indicates whether the HSCSD service is activated at BSC side or not.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TRUE
FALSE
TRUE
DISABLED
ENABLED
ENABLED
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1719
CML:BSC e
Id:0900d805800cecb6
ENMDL
enableNormalMeas
This parameter allows to enable or disable the Normal Measures.
Validity Range
Default Value
Contained in the following commands:
CREATE SCA, GET SCA, SET SCA
ENPERNOTDE
enablePeriodicalNotifDedicatedChan
This attribute enables/disables the periodical notification repetition on dedicated chan-
nels.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
ENVANAME
envaName
TRUE
FALSE
FALSE
TRUE
FALSE
<NULL>
This parameter represents the alarm type identifier. The meaning of
the setting values is the following:
SMOKE Smoke detection alarm.
INTR Intrusion detection alarm.
TRANSMEQP Transmission equipment alarm.
MAINPWR-
SUPP
Main power supply alarm.
OPERATOR-
DEF
Operator defined alarm.


1720 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
None.
Contained in the following commands:
CREATE ENVA, GET ENVA, SET ENVA
EPA
enablePairing
This parameter allows to enable/disable the Enhanced Pairing for TCH/H channels
feature.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
DOOR_OPEN Enclosure door open alarm.
FIRE Fire detected alarm.
HEAT_VENT Air conditioning equipment alarm.
HUMIDITY Humidity unacceptable alarm.
TEMPERA-
TURE
Temperature unacceptable alarm.
SMOKE
INTR
TRANSMEQP
MAINPWRSUPP
OPERATORDEF
DOOR_OPEN
FIRE
HEAT_VENT
HUMIDITY
TEMPERATURE
TRUE
FALSE
TRUE


A30808-X3247-M230-6-7619

1721
CML:BSC e
Id:0900d805800cecb6
EPAT1
enhancedPairingThreshold1
This parameter is the threshold that indicates the percentage of idle TCHs in case of
standard cell or complete area of a concentric cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EPAT2
enhancedPairingThreshold2
This parameter is the threshold that indicates the percentage of idle TCHs in case of
inner area of a concentric cell or near area of an extended cell.
Extended cell: EPA (enhanced pairing) is not permitted in far area due to radio prob-
lems.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EPOOL
enablePooling
The EPOOL (enablePooling) parameter indicates whether the pooling feature is acti-
vated on the BSC side.
0 - 10000
4000
0 - 10000
4000


1722 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
EPRE
enablePreemption
This attribute is used to enable/disable the Preemption feature.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EPREHSCSD
enablePreemptionHSCSD
This attribute enables Preemption for HSCSD requests
(is meaningless if ENHSCSD=FALSE).
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
EPWCRLFW
enablePowerControlRLFW
This attribute indicates whether the MS and BS power control
TRUE
FALSE
FALSE
DISABLED
ENABLED
DISABLED
DISABLED
ENABLED
DISABLED


A30808-X3247-M230-6-7619

1723
CML:BSC e
Id:0900d805800cecb6
procedure due to radio link failure warning is enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EQ
enableQueuing
This attribute is used to enable/disable queuing for TCH channels. When the Enable
Queuing feature is disabled, no TCH request is queued but all TCH channels already
queued are considered.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EQUPOS
equipmentPosition
The attribute defines the position of the NE.
Validity Range
Default Value
Contained in the following commands:
GET BSCE, SET BSCE
TRUE
FALSE
TRUE
DISABLED
ENABLED
DISABLED
6..6 characters string
"010101"


1724 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
ERRACT
errorAct
When errorAct is set to one threshold, all the alarms of lower and equal priority are
ignored.
The parameter errorAct can assume the value FERMAINT only in case of Processing
Failure Event.
The Processing Failure Alarms from the Call Processing are normally disabled, but
when errorAct assumes the value FERMAINT the Processing Failure alarms from the
Call Processing are enabled.
This parameter indicates the event type and it is composed by the
following five fields:
communicationFailureEvent
qualityOfServiceFailureEvent
processingFailureEvent
equipmentFailureEvent
environmentalFailureEvent


A30808-X3247-M230-6-7619

1725
CML:BSC e
Id:0900d805800cecb6
Validity Range
Default Value
communicationFail-
ureEvent
CRITICAL
MAJOR
MINOR
WARNING
NOFILTER
qualityOfService-
FailureEvent
CRITICAL
MAJOR
MINOR
WARNING
NOFILTER
processingFailu-
reEvent
CRITICAL
MAJOR
MINOR
WARNING
NOFILTER
FERMAINT
equipmentFailu-
reEvent
CRITICAL
MAJOR
MINOR
WARNING
NOFILTER
environmentalFailu-
reEvent
CRITICAL
MAJOR
MINOR
WARNING
NOFILTER
communicationFail-
ureEvent
NOFILTER
qualityOfService-
FailureEvent
NOFILTER


1726 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Contained in the following commands:
GET BSC, SET BSC
ERRCORMTD
ccss7ErrorCorrectionMethod
This parameter defines the error correction method used for CCSS7.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
ERROR
error
This attribute forces the application to ask user confirmation for script abort.
Validity Range
Default Value
None.
Contained in the following commands:
EXEC LMT-INTERNAL
ERUDGR
enableRateUpDowngrade
processingFailu-
reEvent
NOFILTER
equipmentFailu-
reEvent
NOFILTER
environmentalFailu-
reEvent
NOFILTER
BASIC_ERROR_CORREC
TION
PREVENTIVE_CYCLIC_R
ETRANS_ERR_CORR
BASIC_ERROR_CORREC
TION
NO
YES


A30808-X3247-M230-6-7619

1727
CML:BSC e
Id:0900d805800cecb6
This flag indicates whether evaluations for rate up-downgrading for 14.4kbit/s data
services are enabled or disabled.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET HAND, SET HAND
ESUP
edgeSupport
This attribute indicates if BSC supports EDGE.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
ETFO
enableTFO
The ETFO (Enable Tandem Free Operation) flag allows to enable or disable the TFO
mode.
In TFO mode the uplink TRAU frames are not decoded to 64kbit/s PCM speech samples
but are transmitted in the TFO speech frames which are transported on the A interface
between two TRAUs. In addition to these TFO speech frames the signalling information
are transferred on the A interface.
The TFO operation is only implemented in all mobile to mobile speech calls where both
TRAUs use the same GSM transcoder.
TRUE
FALSE
<NULL>
TRUE
FALSE
FALSE


1728 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
ETIME
externalTime
This parameter defines the time and date in the BSS.
Validity Range
Default Value
None.
Contained in the following commands:
GET MEL, SET MEL
ETXDIVTS
enableTxDivTimeShift
This parameter allows to switch between coverage mode (enabled) and standard mode
(disabled).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TRUE
FALSE
FALSE
hour 0 - 23
minute 0 - 59
second 0 - 59
day 1 - 31
month 1 - 12
year 1992 - 2099
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1729
CML:BSC e
Id:0900d805800cecb6
EUBCHO
enableBetterCellHoToUmts
This attribute is used to enable/disable "Better Cell " HO to UMTS.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
EUHO
enableHoFromGsmToUmts
This attribute is used to enable/disable GSM to UMTS handovers.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
EUIMPHO
enableImperativeHoToUmts
This attribute is used to enable/disable "Imperative " HO to UMTS .
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE


1730 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
EUMSSNCRESEL
enableUmtsMssNcResel
This attribute shall be used to enable the "mobile speed sensitivity" of the NC
GSM/GPRS to UMTS cell reselection algorithm.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
EUSCHO
enableSufficientUmtsCoverageHoToUmts
This attribute is used to enable/disable Sufficient Coverage Handover to UMTS.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
EUSCNCRESEL
enableUmtsSuffCovNcResel
This attribute shall be used to enable NC cell reselection from GSM/GPRS to UMTS due
to sufficient UMTS coverage.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1731
CML:BSC e
Id:0900d805800cecb6
EUSDCHO
enableUmtsSdcchHo
This attribute is used to enable/disable SDCCH Handover and Directed Retry to UMTS.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
EVTYP
eventType
This attribute defines the type of monitored event.
Validity Range
Default Value
None.
Contained in the following commands:
GETACTIVEALARMS BSCE
EXCDIST
excessiveDistance
This attribute specifies the distance limit to be used for call release.
TRUE
FALSE
<NULL>
FALSE
COMMUNICATION_FAILU
RE_EVENT
QUALITY_OF_SERVICE_
FAILURE_EVENT
PROCESSING_FAILURE_
EVENT
EQUIPMENT_FAILURE_E
VENT
ENVIRONMENTAL_FAILU
RE_EVENT


1732 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecb6
e
Validity Range
Default Value
100 km for Extended cells
35 km for Not Extended cells
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
EXPSWV
expectedSwVersion
1 - 100 1 .. 100 km for Extended cells
1 .. 35 km for Not Extended cells
This parameter is a 26 characters string having the following format
(SS-VV-RR-PR-LL-CL_YY-MM-DD):
SS System
VV Version
RR Release
PR Point Release
LL Load Level
CL Consolidation
Level
YY Year
MM Month
DD Day
The ESVRString SS, VV, RR, LL and CL have to match with the
version of the BTSE software load or of the TRAU software load (in
dependence on the command that uses it) stored in the directory of
the BSC disk. In case of BTSE software load note that:
VV = 01 for
BS-20, BS-21E, BS-22, BS-60, BS-61E.
VV = 04 for
BS-240, BS-241, BS-240SR, BS-241SR,
BS-240XL, BS-240XLSR, BS-240XS,
BS-40, BS-41, BS-82.
Regarding RR sub-field, note that:
RR = 13, 14, 15 for BR6.0 release
RR > 16 for BR7.0 release
RR = 17 for BR8.0 release


A30808-X3247-M230-6-7619

1733
CML:BSC e
Id:0900d805800cecb6
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTSM, CREATE TRAU, GET BTSM, GET TRAU, SET BTSM, SET TRAU
EXTCHO
enableExtendedCellHo
This flag is used to enable the handover handling on the extended cell.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
EXTMODE
extendedMode
The attribute defines, in case of extended cell, if the channel will be used in extended
mode or not.
Validity Range
Default Value
Contained in the following commands:
CREATE CHAN, GET CHAN
In case of TRAU software load note that:
PR = 03 for TRAU
PR = 01 (BTSPlus), 05 (eMicro), 06 (BTS240XS)
Value 00 is referred to the BTSone.
26..26 characters string
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE


1734 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
f
FACCHQ
facchQual
This attribute defines the number of FACCH-halfburst to be received for detecting a
FACCH frame.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FALLBESU
fallbackESU
This parameter defines the ESU (Executable Software Unit) will be used for restoring
the "backup" .
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCOSUDB, GET BSCOSUSW
FCRATE
lowPassFilterCoefficientLeakRate
This parameter is the Low Pass Filter Coefficient used to filter Leak_Rate oscillation.
The filtering applied is the following:
Rmax_eFC=alpha*Rmax(Tnow)+(1-alpha)*Rmax(Tnow-C).
0 - 7
5
<ANY>
<NULL>


A30808-X3247-M230-6-7619

1735
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
FCTRL
flowControlNegotiation
This read-only parameter shows the status of the flow control
negotiation flag.
Validity Range
Default Value
YES
Contained in the following commands:
GET X25A, GET X25D
FDDARFCN
fddArfcn
This parameter represents the carrier frequency of the UMTS cell.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTFDD, GET TGTFDD, SET TGTFDD
0 - 100
100
NO
YES
412 - 10838 412..687 (allowed values 412, 437, 462, 487, 512, 537,
562, 587, 612, 637, 662, 687)
1007..1087 (allowed values 1007, 1012, 1032, 1037,
1062, 1087)
4357..4458
9662..9938
10562..10838


1736 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
FDDDIV
fddDiversity
This parameter indicates if diversity is used or not in FDD cell.
Validity Range
Default Value
NO_DIVERSITY
Contained in the following commands:
CREATE TGTFDD, GET TGTFDD, SET TGTFDD
FDDGQO
fddGPRSQOffset
This parameter relates multiRAT mobiles; it indicates an offset which is applied for
carrier level of serving cell; it has to be combined with the parameter FDDQMI
(fddQMin).
NO_DIVERSITY means that SCTD is not applied for this cell
DIVERSITY means that SCTD is applied for this cell


A30808-X3247-M230-6-7619

1737
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
FDDMURREP
fddMultiratReporting
This parameter indicates the number of FDD UTRAN cells to include in the measure-
ment report.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDQMI
fddQMin
ALWAYS
MDB28
MDB24
MDB20
MDB16
MDB12
MDB08
MDB04
DB00
DB04
DB08
DB12
DB16
DB20
DB24
DB28
DB00
0 - 3
0


1738 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
This parameter is a threshold for signal Ec/No. When the FDD
adjacent level carrier is higher than serving cell of FDDGQO
(fddGprsqOffset) and Ec/No is higher than FDDQMI (fddQMin), fdd_ms selects the
adjacent FDD cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDQMIO
fddQMinOffset
This parameter related multiRAT mobiles; it is used by them to implement cell re-selec-
tion algorithm from GSM to UTRAN.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
MDB20
MDB06
MDB18
MDB08
MDB16
MDB10
MDB14
MDB12
MDB12
DB00
DB02
DB04
DB06
DB08
DB10
DB12
DB14
DB00


A30808-X3247-M230-6-7619

1739
CML:BSC f
Id:0900d805800cecbb
FDDQO
fddQOffset
This parameter relates multiRAT mobiles; it indicates an offset which is applied to level
of FDD serving cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDREPO
fddReportOffset
This parameter defines offset to be applied to reported cells.
ALWAYS
MDB28
MDB24
MDB20
MDB16
MDB12
MDB08
MDB04
DB00
DB04
DB08
DB12
DB16
DB20
DB24
DB28
DB00


1740 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDREPQTY
fddReportingQuantity
This parameter indicates the reporting quantity for UTRAN FDD cells.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDREPTH
fddReportThreshold
This parameter defines threshold which UTRAN cell has to exceed in order to be
reported in Enhanced Measurement Report.
db_00
db_06
db_12
db_18
db_24
db_30
db_36
db_42
db_00
RSCP
EC_NO
RSCP


A30808-X3247-M230-6-7619

1741
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDREPTH2
fddReportThreshold2
This parameter is the threshold which each reported 3G FDD adjacent cell has to
exceed with its not-reported value.
When FDDREPQTY=0 not-reported value=Ec/No
.When FDDREPQTY=1 not-reported value=RSCP
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDRSCPMI
fddRscpMin
This attribute relates multiRAT mobiles; it is used by them to implement cell re-selection
algorithm from GSM to UTRAN.
rxlev_00
rxlev_06
rxlev_12
rxlev_18
rxlev_24
rxlev_30
rxlev_36
never
rxlev_00
0 - 63
0


1742 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FDDSCRMC
fddScramblingCode
This parameter represents the Primary Scrambling Code of the UMTS cell.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTFDD, GET TGTFDD, SET TGTFDD
MDB115
MDB113
MDB111
MDB109
MDB107
MDB105
MDB103
MDB101
MDB099
MDB097
MDB095
MDB093
MDB091
MDB089
MDB087
MDB085
MDB101
0 - 511


A30808-X3247-M230-6-7619

1743
CML:BSC f
Id:0900d805800cecbb
FER
frameErasureRate
Validity Range
Default Value
Contained in the following commands:
CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX
This parameter requires 7 input values which define the 8 ranges of
Frame Erasure Rate (FER), in promille %0, (Input_value1,
Input_value2,.., Input_value7);
The allowed input values for FER are 0 to 1000, defined by means
of "rangeBound<n>" fields (<n>=1..7).
The correspondence between the Input_values and FER is the fol-
lowing:
FER_Range0: FER<= Inputvalue1
FER_Range1:Input_value1 <FER<= Inputvalue2
FER_Range2:Input_value2 <FER<= Inputvalue3
FER_Range3:Input_value3 <FER<= Inputvalue4
FER_Range4:Input_value4 <FER<= Inputvalue5
FER_Range5:Input_value5 <FER<= Inputvalue6
FER_Range6:Input_value6 <FER<= Inputvalue7
FER_Range7:Input_value7 <FER
rangeBound1 0 - 1000
rangeBound2 0 - 1000
rangeBound3 0 - 1000
rangeBound4 0 - 1000
rangeBound5 0 - 1000
rangeBound6 0 - 1000
rangeBound7 0 - 1000
rangeBound1 10
rangeBound2 20
rangeBound3 30
rangeBound4 40
rangeBound5 50
rangeBound6 100
rangeBound7 200


1744 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
FERSERTYPE
ferServiceType
This parameter defines the service type of the TCH connections.
Validity Range
Default Value
Contained in the following commands:
CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX
FHAMRFRC1
fhAMRFullRateCodec1
TCH_FS
TCH_HS
TCH_EFS
TCH_FS_EFS
TCH_AFS
TCH_FS_AFS
TCH_EFS_AFS
TCH_FS_EFS_AFS
TCH_AHS
TCH_HS_AHS
TCH_FS
This parameter indicates the first (most robust) AMR (Adaptive Mul-
tiRate) active codec in case of Full Rate codec when the frequency
hopping is enabled.
The following bit rate can be set:
RATE_01 4.75 kbit/s
RATE_02 5.15 kbit/s
RATE_03 5.90 kbit/s
RATE_04 6.70 kbit/s
RATE_05 7.40 kbit/s
RATE_06 7.95 kbit/s
RATE_07 10.2 kbit/s
RATE_08 12.2 kbit/s


A30808-X3247-M230-6-7619

1745
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
RATE_01
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRFRC2
fhAMRFullRateCodec2
This parameter indicates the second AMR (Adaptive MultiRate) active codec in case of
Full Rate codec when the frequency hopping is enabled.
For the bit rate numerical values refer to FHAMRFRC1 parameter.
Validity Range
Default Value
RATE_03
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>


1746 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
FHAMRFRC3
fhAMRFullRateCodec3
This parameter indicates the third AMR (Adaptive MultiRate) active codec in case of Full
Rate codec when the frequency hopping is enabled.
For the bit rate numerical values refer to FHAMRFRC1 parameter.
Validity Range
Default Value
RATE_06
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRFRC4
fhAMRFullRateCodec4
This parameter indicates the fourth (least robust) AMR (Adaptive MultiRate) active
codec in case of Full Rate codec when the frequency hopping is enabled.
For the bit rate numerical values refer to FHAMRFRC1 parameter.
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>


A30808-X3247-M230-6-7619

1747
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
RATE_08
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRFRIC
fhAMRFullRateInitialCodec
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
RATE_06
RATE_07
RATE_08
<NULL>
This parameter defines the Initial Codec Mode, i.e. the Full Rate
active codec mode which must be sent at first during a call when the
frequency hopping is enabled.
START_MODE_FR value depends on the number of codec modes
contained in the Active Codec Set, which is equal to the number of
AMRFRCi attributes set at a value different from NULL.
The rule is the following.
If the Active Codec Set contains:
1 mode this is the Initial Codec Mode;
2 or 3 modes the Initial Codec Mode is the most robust
mode of the set (i.e. the one with lowest
bit rate);
4 modes the Initial Codec Mode is the second most
robust mode of the set (i.e. the one with
second lowest bit rate).
CODEC_MODE_0i value corresponds to AMRFRCi value.


1748 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
START_MODE_FR
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRFRTH12
fhAMRFullRateThresholds12
This parameter defines the couple "threshold-hysteresis" related to the active codecs
specified in the FHAMRFRC1 and FHAMRFRC2 attributes in case of Full Rate codec
when the frequency hopping is enabled.
The numerical range for the threshold is 0 to 31.5 dB and for
hysteresis is 0 to 7.5 dB.
Validity Range
Default Value
Threshold : 7 [3.5 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRFRTH23
fhAMRFullRateThresholds23
This parameter defines the couple "threshold-hysteresis" related to the active codecs
specified in the AMRFRC2 and AMRFRC3 attributes in case of Full Rate codec when
the frequency hopping is enabled.
The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB.
START_MODE_FR
CODEC_MODE_01
CODEC_MODE_02
CODEC_MODE_03
CODEC_MODE_04
<NULL>
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>


A30808-X3247-M230-6-7619

1749
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
Threshold : 12 [6.0 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRFRTH34
fhAMRFullRateThresholds34
This parameter defines the couple "threshold-hysteresis" related to the active codecs
specified in the AMRFRC3 and AMRFRC4 attributes in case of Full Rate codec when
the frequency hopping is enabled.
The numerical range for the threshold is 0 to 31.5 dB and for hysteresis is 0 to 7.5 dB.
Validity Range
Default Value
Threshold : 23 [11.5 dB]
Hysteresis : 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRC1
fhAMRHalfRateCodec1
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>
This attribute indicates the first (most robust) AMR active codec in
case of Half Rate codec when the frequency hopping is enabled. The
following bit rate can be set:
RATE_01 4.75 kbit/s
RATE_02 5.15 kbit/s
RATE_03 5.90 kbit/s
RATE_04 6.70 kbit/s
RATE_05 7.40 kbit/s


1750 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
RATE_01
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRC2
fhAMRHalfRateCodec2
This attribute indicates the second AMR active codec in case of Half Rate codec when
the frequency hopping is enabled. For the bit rate numerical values refer to
FHAMRHRC1 parameter.
Validity Range
Default Value
RATE_02
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRC3
fhAMRHalfRateCodec3
This attribute indicates the third AMR active codec in case of Half Rate codec when the
frequency hopping is enabled. For the bit rate numerical values refer to FHAMRHRC1
parameter.
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>


A30808-X3247-M230-6-7619

1751
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
RATE_03
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRC4
fhAMRHalfRateCodec4
This attribute indicates the fourth (least robust) AMR active codec in case of Half Rate
codec when the frequency hopping is enabled. For the bit rate numerical values refer to
FHAMRHRC1 parameter.
Validity Range
Default Value
RATE_04 for BTS+ family and
NULL for BTSE type 1 family
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRIC
fhAMRHRInitialCodec
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>
RATE_01
RATE_02
RATE_03
RATE_04
RATE_05
<NULL>
This parameter defines the Initial Codec Mode, i.e. the Half Rate
active codec mode which must be sent at first during a call when the
frequency hopping is enabled.


1752 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
START_MODE_HR
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRTH12
fhAMRHalfRateThresholds12
This attribute indicates the couple "threshold-hysteresis" related to the active codecs
specified in the AMRHRC1 and AMRHRC2 attributes in case of Half Rate codec when
the frequency hopping is enabled.
Validity Range
Default Value
Threshold : 19 [9.5 dB]
Hysteresis : 4 [2.0 dB]
START_MODE_HR value depends on the number of codec modes
contained in the Active Codec Set, which is equal to the number of
AMRHRCi attributes set at a value different from NULL.
The rule is the following.
If the Active Codec Set contains:
1 mode this is the Initial Codec Mode;
2 or 3 modes the Initial Codec Mode is the most robust
mode of the set (i.e. the one with lowest bit
rate);
4 modes the Initial Codec Mode is the second most
robust mode of the set (i.e. the one with
second lowest bit rate).
CODEC_MODE_0i value corresponds to AMRHRCi value.
START_MODE_HR
CODEC_MODE_01
CODEC_MODE_02
CODEC_MODE_03
CODEC_MODE_04
<NULL>
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>


A30808-X3247-M230-6-7619

1753
CML:BSC f
Id:0900d805800cecbb
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRTH23
fhAMRHalfRateThresholds23
This attribute indicates the couple "threshold-hysteresis" related to the active codecs
specified in the AMRHRC2 and AMRHRC3 attributes in case of Half Rate codec when
the frequency hopping is enabled.
Validity Range
Default Value
Threshold : 24 [12.0 dB]
Hysteresis: 4 [2.0 dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FHAMRHRTH34
fhAMRHalfRateThresholds34
This attribute indicates the couple "threshold-hysteresis" related to the active codecs
specified in the AMRHRC3 and AMRHRC4 attributes in case of Half Rate codec when
the frequency hopping is enabled.
Validity Range
Default Value
Threshold : 26 [13.0 dB for BTSP family and
<NULL> for BTSE family]
Hysteresis : 2 [2.0dB]
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>
Threshold 0 - 63 (0.5 dB step size)
Hysteresis 0 - 15 (0.5 dB step size)
<NULL>


1754 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
FHORLMO
fHORxLevMinOffset
Validity Range
Default Value
6 dB
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
FHSYID
frequencyHoppingID
This parameter represents the frequency hopping system identifier used by the channel.
The FHSY0 value corresponds to "no hopping" setting.
This attribute defines the 'forced handover received level minimum
offset' which is used by the handover decision algorithm to deter-
mine whether a neighbour cell is regarded as suitable target cell for
forced handover or not.
It enhances the minimum criteria defined by the attribute
RXLEVMIN.
0 - 24 (1 dB step size)
<NULL>


A30808-X3247-M230-6-7619

1755
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
In moc(s) CHAN:
None.
In moc(s) TRX:
Contained in the following commands:
CREATE CHAN, CREATE TRX, GET CHAN, GET TRX, SET CHAN, SET TRX
FILE
file
This parameters defines the file name.
Validity Range
In commands UPLCIDF REMINV, UPLLIDF REMINV:
In commands UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG
SOFTWARE-MANAGEMENT, UPLFILE SOFTWARE-MANAGEMENT, UPLTRAU-
LOG SOFTWARE-MANAGEMENT:
Default Value
None.
FHSY_0
FHSY_1
FHSY_2
FHSY_3
FHSY_4
FHSY_5
FHSY_6
FHSY_7
FHSY_8
FHSY_9
FHSY_10
CFHSY_0
CFHSY_1
<NULL>
NULL
0..30 characters string
1..30 characters string


1756 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG SOFTWARE-MAN-
AGEMENT, UPLCIDF REMINV, UPLFILE SOFTWARE-MANAGEMENT, UPLLIDF
REMINV, UPLTRAULOG SOFTWARE-MANAGEMENT
FILENAME
fileName
This attribute defines the file to be executed.
Validity Range
Default Value
None.
Contained in the following commands:
EXEC LMT-INTERNAL
FILETYPE
fileType
This attribute specifies the type of file content.
This attribute must be set always to EVENT_LOG.
Validity Range
In commands UPLTRAULOG SOFTWARE-MANAGEMENT:
In commands UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG
SOFTWARE-MANAGEMENT:
Default Value
None.
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG SOFTWARE-MAN-
AGEMENT, UPLTRAULOG SOFTWARE-MANAGEMENT
1..80 characters string
EVENT_LOG
MIT_BUFFER
ALARM_BUFFER
MIT_BUFFER


A30808-X3247-M230-6-7619

1757
CML:BSC f
Id:0900d805800cecbb
FLAPDOVLTH
firstLapdOverloadThreshold
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
FLOWCTH
flowcThreshold
The flow control threshold determines the percentage of receive buffers used and
notifies the congestion to the remote MSC (or SMLC).
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
FPER
flowPercentage
Fper is common to MS and PFC; this parameter is the shrinking value used in case of
PDU life time expiration or in case of Bucket Ratio not supported in order to reduce R
value sent to SGSN.
This attribute indicates the first level thresholds (in percentage) of
the BTSE Radio Signalling Links (LPDLRs). It consists of two fields:
"upperThreshold"
if the signalling traffic overcomes this threshold the BTSE
suspends sending measurement report messages.
"lowerThreshold"
if the signalling traffic falls below this threshold the BTSE
resumes sending measurement report messages.
upperThreshold 10 - 100
lowerThreshold 10 - 100
80
70
0 - 9
3


1758 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
FRACTAMRTH1
fullRateActivationAMRThreshold1
This parameter is the threshold that indicates the percentage of busy TCHs for AMR
calls in case of standard cell or complete area of a concentric cell or far area of an
extended cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FRACTAMRTH2
fullRateActivationAMRThreshold2
This parameter is the threshold that indicates the percentage of busy TCHs for AMR
calls in case of inner area of a concentric cell or near area of an extended cell.
per_05
per_10
per_15
per_20
per_25
per_30
per_35
per_40
per_45
per_50
per_15
0 - 10000
3000


A30808-X3247-M230-6-7619

1759
CML:BSC f
Id:0900d805800cecbb
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FRACTTH1
fullRateActivationThreshold1
This parameter is the threshold that indicates the percentage of busy TCHs in case of
standard cell or complete area of a concentric cell or far area of an extended cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FRACTTH2
fullRateActivationThreshold2
This parameter is the threshold that indicates the percentage of busy TCHs in case of
inner area of a concentric cell or near area of an extended cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FRANOFFS
frameNumberOffset
This parameter is an integer that indicates the frame number offset of a BTS.
0 - 10000
3000
0 - 10000
3000
0 - 10000
3000


1760 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecbb
f
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
FRSTD
frameRelayStandard
This attribute identifies the standard of the frame relay.
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
FRTERM
fromTermination
This attribute identifies the termination (timeslot) which the cross connection starts from.
It consists of two fields: "PcmLine "and "Tsl" (timeslot).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE NUC, GET NUC
0 - 255
<NULL>
ITU
ANSI
LMI
ITU
PcmLine Pathname PCMA: pcma#
PCMB: pcmb#
PCMS: pcms#
Tsl 1 - 31 1..31 for PCM30
1..24 for PCM24


A30808-X3247-M230-6-7619

1761
CML:BSC f
Id:0900d805800cecbb
FULHOC
fastULHoCell
This parameter indicates whether the adjacent cell is a predefined fast uplink handover
cell.
When searching a target cell for a fast uplink handover, cells that have the attribute
FULHOC set at TRUE will be preferred to cells that have this attribute set to FALSE.
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
FULRXLVMOFF
fastULRxLevMinOffset
The value of this parameter is used to select a target cell for fast uplink handover.
The value 0 corresponds to -63 dB and the value 126 corresponds to +63 dB (0 dB cor-
respond to 63 value).
Validity Range
Default Value
69 [6 dB]
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
TRUE
FALSE
<NULL>
0 - 126 (1 dB step size)
<NULL>


1762 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
g
GAM
gamma
This parameter defines the "gamma" value applied in the power control algorithm. The
set value ranges from 0 dB to 62 dB (2 dB step size). Default value 3 corresponds to 6
dB.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GASTRABISTH
gprsAllocationStrategyAbisThresholds
0 - 31
3
This parameter is used to control the switch from/to vertical/horizon-
tal allocation strategy and the stop/restore of Abis upgrading due to
Abis scarcity. It is composed of four fields.
The first one (thresholdIdleAbisHV) defines the percentage of idle
Abis subslots (over the available Abis subslots) under which the
Vertical allocation strategy for Abis scarcity is activated. To activate
the vertical allocation in case of Abis scarcity is useful to re-use in
multiplexing the already allocated Abis subslots, slowing down the
allocation of new Abis resources.
The second one (thresholdIdleAbisVH) defines the percentage of idle
Abis subslots (over the available Abis subslots) over which the
Horizontal allocation can be activated again, if also the thresholds on
radio resources allow that.
The third one (thresholdIdleAbisSU) defines the percentage of idle
Abis subslots (over the available Abis subslots) under which the PCU
must disable the Abis upgrading requests to TDPC. When this
threshold is overcome, the first allocation of Abis resources to a TBF
is performed with the same criteria used under normal conditions
(looking at the candidate initial coding scheme), but further upgrading
of Abis resources is forbidden. Moreover, in case of runtime Abis
release (due to worsening of radio conditions, CS pre-emption or
O&M commands), the released Abis is not allowed to be allocated
again to running TBFs.


A30808-X3247-M230-6-7619

1763
CML:BSC g
Id:0900d805800cecc0
Validity Range
Default Value
ThresholdIdle-AbisHV 10
ThresholdIdle-AbisVH 20
ThresholdIdle-AbisSU 0
ThresholdIdle-AbisRU 10
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
The main aim of this threshold is avoiding useless signalling between
PCU and TDPC in case of nearly complete Abis congestion, there-
fore, the default value of the threshold is 0, meaning that the Abis
upgrading is disabled only in case of complete Abis congestion. The
secondary aim of this threshold is to avoid the allocation of additional
Abis resources to running packet services in case of Abis scarcity, so
that the residual Abis resources in the pool can be by preference
available to set up new CS services (this will be the trend in case of
vertical
allocation) or even to new PS services (in case horizontal allocation
is still active). Note that moving this threshold from the default value,
a reduction in PS throughput is expected.
The fourth one (thresholdIdleAbisRU) defines the percentage of idle
Abis subslots (over the available Abis subslots) over which the Abis
upgrade requests to TDPC are restored.
Constraints on the Abis thresholds are:
thresholdIdleAbisSU <= thresholdIdleAbisRU;
thresholdIdleAbisHV <= thresholdIdleAbisVH.
Note that there is no constraint between the Abis threshold to switch
to vertical allocation and the Abis threshold to disable the 'Abis
upgrade requests'; the operator is free to set the one lowest than the
other, and vice versa.
thresholdIdleAbisHV 0 - 100
thresholdIdleAbisVH 0 - 100
thresholdIdleAbisSU 0 - 100
thresholdIdleAbisRU 0 - 100
<NULL>


1764 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
GASTRTH
gprsAllocationStrategyThresholds
The GASTRTH (gprsAllocationStrategyThresholds) parameter
concerns the percentage of idle channels in the cell in order to
trigger the switch between Horizontal Allocation (HA) and Vertical
Allocation (VA) strategy, and in order to enable/disable the allocation
of new PDCHs to extend a TBF after the first resource assignment
(upgrading of packet radio resources).
It consists of three fields: the first (ThresholdIdleChanHV) one
indicates the threshold under which the vertical strategy is used and
under which the upgrading of radio resources is disabled; note that
when the upgrading of radio resources is disabled, the extension of
a TBF, if necessary and possible, is performed in multiplexing over
already allocated adjacent PDCHs.
The second one (ThresholdIdleChanVH) represents the threshold
over which the horizontal one is used.
The third one (ThresholdIdleChanEU) indicates the threshold over
which the upgrading of radio resources is enabled.
The first field "ThresholdIdleChanHV" has to be lower than or equal
to the second one "ThresholdIdleChanVH".
The second field "ThresholdIdleChanVH" has to be lower than or
equal to the third one "ThresholdIdleChanEU".
The GASTRTH fields have to be intended as a percentage of free
PDCHs referred to the number of available channels (TCHs and
PDCHs), except the static PDTCHs, in the whole cell. The total
number of idle channels changes due to GPRS and CS load. For
example it is possible to switch from the horizontal allocation to the
vertical one also if no CS call is going on.


A30808-X3247-M230-6-7619

1765
CML:BSC g
Id:0900d805800cecc0
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GATEWAY0
gateway0
This attribute is the IP address of the default gateway connected to the MPCC copy 0.
It is present only if either the RC or the CBC (or both) does not belong to the same IP
sub-network of the BSC. The convention used for his value is the well-known dotted
decimal format.
Validity Range
Default Value
Contained in the following commands:
CREATE IPLI, GET IPLI, SET IPLI
GATEWAY1
gateway1
This attribute is the IP address of the default gateway connected to the MPCC copy 1.
It is present only if either the RC or the CBC (or both) does not belong to the same IP
sub-network of the BSC. The convention used for his value is the dotted decimal format.
Threshold-
IdleChanHV
0 - 100
Threshold-
IdleChanVH
0 - 100
ThresholdIdleCha-
nEU
0 - 100
Threshold-
IdleChanHV
10
Threshold-
IdleChanVH
20
ThresholdIdleCha-
nEU
20
0..15 characters string
<NULL>
NULL


1766 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
Validity Range
Default Value
Contained in the following commands:
CREATE IPLI, GET IPLI, SET IPLI
GBSNS
gBSubNetworkService
This attribute indicates the sub network service used for CPU.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
GCELLRESH
gprsCellReselectHysteresis
This attribute indicates the hysteresis to be subtracted from the C32 value of the neigh-
bouring cell, when the MS is in ready state and the neighbouring cell belongs to the
same Routing Area (RA).
The set value ranges from 0 dB to 14 dB (2 dB step size). Default value 2 corresponds
to 4 dB.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
0..15 characters string
<NULL>
NULL
FRFIX
FRVAR
IPV4
FRFIX
0 - 7
2


A30808-X3247-M230-6-7619

1767
CML:BSC g
Id:0900d805800cecc0
GDCH
gprsDedicatedChannel
This parameter is used to statically allocate a GPRS channel for signalling.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CHAN, GET CHAN, SET CHAN
GEXTS
gprsExtension
This parameter specifies if GPRS/EGPRS has to be allowed also in non-BCCH bands.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
GFDDMURREP
gprsFddMultiratReporting
This parameter indicates the number FDD UTRAN cells to include in the measurement
report by gprs_attached mobile.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PBCCH
PCCCH
<NULL>
ALL900 (0)
ALLFREQ (1)
<NULL>
NULL
0 - 3 (step 1)
2


1768 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
GFDDQMI
gprsFddQMin
This parameter is a threshold for signal Ec/No.
When the fdd adjacent level carrier is higher than serving cell of fddgprsqoffset and
Ec/No is higher than fddqmin , gprs attached fdd_ms selects the adjacent fdd cell:
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GFDDQMIO
gprsFddQMinOffset
This parameter relates multiRAT mobiles; it is used by them to implement cell re-selec-
tion algorithm from GPRS to UTRAN.
MDB20
MDB06
MDB18
MDB08
MDB16
MDB10
MDB14
MDB12
<NULL>
NULL


A30808-X3247-M230-6-7619

1769
CML:BSC g
Id:0900d805800cecc0
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GFDDREPQTY
gprsFddReportingQuantity
This parameter indicates the reporting quantity by gprs_attached mobile for UTRAN
FDD cells.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GFDDRSCPMI
gprsFddRscpMin
This attribute relates multiRAT mobiles; it is used by them to implement cell re-selection
algorithm from GPRS to UTRAN.
DB00
DB02
DB04
DB06
DB08
DB10
DB12
DB14
DB00
RSCP
EC_NO
RSCP


1770 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GHCSPC
gprsHierarchicalCellStructPriorityClass
This attribute represents the Hierarchical Cell Structure priority for cell reselection.
Validity Range
In commands CREATE PTPPKF, GET PTPPKF, SET PTPPKF:
In commands CREATE ADJC, GET ADJC, SET ADJC:
Default Value
In moc(s) ADJC:
None.
MDB115
MDB113
MDB111
MDB109
MDB107
MDB105
MDB103
MDB101
MDB099
MDB097
MDB095
MDB093
MDB091
MDB089
MDB087
MDB085
MDB101
0 - 7
0 - 7
<NULL>


A30808-X3247-M230-6-7619

1771
CML:BSC g
Id:0900d805800cecc0
In moc(s) PTPPKF:
Contained in the following commands:
CREATE ADJC, CREATE PTPPKF, GET ADJC, GET PTPPKF, SET ADJC, SET
PTPPKF
GHCSTH
gprsHierarchicalCellStructureThreshold
This attribute indicates the signal strength threshold used in HCS cell reselection proce-
dure. The set value ranges from -110 dB to -48 dB.
Validity Range
In commands CREATE ADJC, GET ADJC, SET ADJC:
In commands CREATE PTPPKF, GET PTPPKF, SET PTPPKF:
Default Value
In moc(s) ADJC:
None.
In moc(s) PTPPKF:
Contained in the following commands:
CREATE ADJC, CREATE PTPPKF, GET ADJC, GET PTPPKF, SET ADJC, SET
PTPPKF
GLK
gprsLink
This attribute defines the PCM line used between SGSN and PCU. It is defined as a
pathname. Mixed configuration A-interface or G-interface are admitted.
This means that it is possible to create some FRL links on PCMA interface and some
others on PCMG.
Validity Range
Default Value
None.
3
0 - 31 (2 dB step size)
<NULL>
0 - 31 (2 dB step size)
10
Pathname (e.g. OBJ1:2/OBJ2:1/OBJ3:5 )


1772 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
Contained in the following commands:
CREATE FRL, GET FRL
GLLCOM
gprsLayerListComplementary
This parameter defines the list of TRX layers assigned to GPRS service in the inner/near
area of dual area cell (extended, concentric single/dual band), or in the complementary
band of a dual band standard cell. The TRX layers are specified in the list in a decreas-
ing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
GLLPRM
gprsLayerListPrimary
This parameter defines the list of TRX layers assigned to GPRS service in a single band
standard cell, or in the complete/far area of a dual area cell (extended, concentric sin-
gle/dual band), or in the BCCH band of a dual band standard cell. The TRX layers are
specified in the list in a decreasing priority order.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


A30808-X3247-M230-6-7619

1773
CML:BSC g
Id:0900d805800cecc0
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
GMANMSAL
gprsMaxNumberMsAllocated
This parameter indicates the maximum number of MSs that can be multiplexed within
one PDCH in the cell.
It is composed of two fields: the first indicates the maximum number of MSs that can be
multiplexed on one PDCH in uplink direction, the second one indicates the maximum
number of MSs that can be
multiplexed on one PDCH in downlink direction. Default values are referred respectively
to upLink and downLink.
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


1774 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GMANPRESCOM
gprsMaxNumberPDCHResComplementary
The attribute defines the number of traffic channels reserved for packet connections,
exclusively on the first layer shared by GPRS and CS service in Complementary Area.
It is related to Near area in extended cell; in case of standard cell, only GMANPRE-
SPRM is meaningful.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GMANPRESPRM
gprsMaxNumberPDCHResPrimary
The attribute defines the number of traffic channels reserved for packet connections,
exclusively on the first layer shared by GPRS and CS service in Primary Area. It is
related to Far area in extended cell; in case of standard cell, only GMANPRESPRM is
meaningful.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
upLink 1 - 7
downLink 1 - 16
7
16
0 - 190
0
0 - 190
0


A30808-X3247-M230-6-7619

1775
CML:BSC g
Id:0900d805800cecc0
GMANRETS
gprsMaxNumberRetransmission
This parameter indicates for each priority level, 1 to 4, the maximum number of retrans-
missions allowed. Default values are referred respectively to: PRIO1, PRIO2, PRIO3
and PRIO 4.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GMICROCU
gprsMicrocellUmts
The attribute specifies whether an UMTS neighbour cell is a UMTS microcell for which
the additional MSS condition of the Mobile Speed Sensitive (MSS) NC GSM/GPRS to
UMTS cell reselection algorithm shall be applied.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
GMSTXPMAC
gprsMsTxPwrMaxCch
This parameter indicates the maximum TX power level an MS may use when accessing
the system when the PBCCH exists. For the serving cell and neighbour cells the
GMSTXPMAC value is broadcast on PBCCH of the serving cell. When the NCRE-
PRIO1 0 - 3
PRIO2 0 - 3
PRIO3 0 - 3
PRIO4 0 - 3
2
2
2
2
TRUE
FALSE
FALSE


1776 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
SELFLAG=ENABLED the BSC uses the GMSTXPMAC value in order to evaluate the
path loss criterion parameters C1 (serving cell) and C1 (neighbour cells).
Note: if the PBCCH does not exist the MS uses the MSTXPMAXCH value to evaluate
the path loss criterion parameter C1 and the BSC uses GMSTXPMAC value to evaluate
the same parameter.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, CREATE TGTPTPPKF, GET PTPPKF, GET TGTPTPPKF, SET
PTPPKF, SET TGTPTPPKF
GNMULBAC
gprsNMultibandCell
This parameter indicates for a multiband ms the number of cells for each frequency band
supported.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GPATH
gprsPriorityAccessThreshold
0 - 31
2
0 - 3
<NULL>
NULL
This parameter indicates whether or not a mobile station of a certain
priority class is authorized to do a random access for request of a
GPRS service. The field is coded according to the following table:
PKANA packet access is not allowed in the cell;
PKAAP1 packet access is allowed for priority class 1;
PKAAP2 packet access is allowed for priority class 1 to 2;
PKAAP3 packet access is allowed for priority class 1 to 3;
PKAAP4 packet access is allowed for priority class 1 to 4;


A30808-X3247-M230-6-7619

1777
CML:BSC g
Id:0900d805800cecc0
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GPDPDTCHA
gprsPercentageOfDynamicPdtchAvailable
This attribute indicates the percentage of available channels
dynamically dedicated by the system to GPRS traffic. These channels are chosen
between those traffic channels for which the GDCH is set at NULL and for which the
superordinate TRX is in service and
available for gprs service (GSUP set at TRUE).
In order to set the GPDPDTCHA parameter the PTPPKF object must be locked.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GPENTIME
gprsPenaltyTime
PKANA
PKAAP1
PKAAP2
PKAAP3
PKAAP4
PKAAP4
0 - 100
100
This attribute gives the duration for which the
GPRS_TEMPORARY_ OFFSET is applied in cell reselection
procedure.
The following list shows the correspondence between selected
values and real values:
0 0 0 0 0 10 seconds
0 0 0 0 1 20 seconds


1778 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
Validity Range
Default Value
0 [10s] and <NULL> for ADJC object only
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
GRANP
granularityPeriod
This attribute represents the duration in minutes of the single period of measurement.
The MINUTES_5 value is not available for the SCANBTSE and SCANBTSM objects.
Validity Range
In commands CREATE SCANBTSE, CREATE SCANBTSM, GET SCANBTSE, GET
SCANBTSM, SET SCANBTSE, SET SCANBTSM:
In commands GET SCANCHAN, GET SCANCTRX, CREATE SCANBSC, CREATE
SCANBTS, CREATE SCANBTSIHO, CREATE SCANBTSOHOI, CREATE SCANBT-
SOHON, CREATE SCANBTSOHOS, CREATE SCANFBTSM, CREATE SCANGPRS,
CREATE SCANSS7L, CREATE SCANTRX, GET SCANBSC, GET SCANBTS, GET
SCANBTSIHO, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS,
GET SCANFBTSM, GET SCANGPRS, GET SCANSS7L, GET SCANTRX, SET
SCANBSC, SET SCANBTS, SET SCANBTSIHO, SET SCANBTSOHOI, SET SCANBT-
SOHON, SET SCANBTSOHOS, SET SCANFBTSM, SET SCANGPRS, SET
SCANSS7L, SET SCANTRX:
Default Value
In moc(s) SCANCHAN, SCANCTRX:
None.
... ...
1 1 1 1 1 320 seconds
0 - 31
<NULL>
MINUTES_15
MINUTES_30
MINUTES_60
MINUTES_5
MINUTES_15
MINUTES_30
MINUTES_60


A30808-X3247-M230-6-7619

1779
CML:BSC g
Id:0900d805800cecc0
In moc(s) SCANFBTSM, SCANBTS, SCANGPRS, SCANBSC, SCANTRX, SCANBT-
SOHOI, SCANBTSOHOS, SCANSS7L, SCANBTSIHO, SCANBTSOHON, SCAN-
BTSE, SCANBTSM:
Contained in the following commands:
CREATE SCANBSC, CREATE SCANBTS, CREATE SCANBTSE, CREATE SCAN-
BTSIHO, CREATE SCANBTSM, CREATE SCANBTSOHOI, CREATE SCANBTSO-
HON, CREATE SCANBTSOHOS, CREATE SCANFBTSM, CREATE SCANGPRS,
CREATE SCANSS7L, CREATE SCANTRX, GET SCANBSC, GET SCANBTS, GET
SCANBTSE, GET SCANBTSIHO, GET SCANBTSM, GET SCANBTSOHOI, GET
SCANBTSOHON, GET SCANBTSOHOS, GET SCANCHAN, GET SCANCTRX, GET
SCANFBTSM, GET SCANGPRS, GET SCANSS7L, GET SCANTRX, SET
SCANBSC, SET SCANBTS, SET SCANBTSE, SET SCANBTSIHO, SET SCAN-
BTSM, SET SCANBTSOHOI, SET SCANBTSOHON, SET SCANBTSOHOS, SET
SCANFBTSM, SET SCANGPRS, SET SCANSS7L, SET SCANTRX
GRESOFF
gprsReselectOffset
Validity Range
Default Value
16 [0 dB] and <NULL> for ADJC object only
MINUTES_60
This attribute specifies to mobile station the positive or negative
offset and hysteresis to be applied to GPRS Reselection Criterion.
The set value ranges from -52 dB to +48 dB; the step size is 4 dB for
the first 11 values, 2 dB for the next 12 values and 4 dB for the last
9 values, as shown in the table below:
0 -52 dB
1 -48 dB
..... ......
10 -12 dB
11 -10 dB
..... ......
22 +12 dB
23 +16 dB
..... ......
31 +48 dB
0 - 31
<NULL>


1780 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
GRXLAMI
gprsRxLevelAccessMin
This parameter defines the minimum received level, at mobile station side, required for
the access to the cell.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, CREATE TGTPTPPKF, GET PTPPKF, GET TGTPTPPKF, SET
PTPPKF, SET TGTPTPPKF
GS
gprsSlot
This parameter is used for calculation of the number of slots between two successive
Channel request messages on PRACH channel.
Note: The optimal value for the GS parameter is the default one (GS=8). It is strongly
advised the operator against the modification of this value to a smaller one and above
all it have to be avoided the value GS=0.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GSUP
gprsSupported
This attribute indicates whether the adjacent cell supports the GPRS service or not.
0 - 63
6
0 - 9
8


A30808-X3247-M230-6-7619

1781
CML:BSC g
Id:0900d805800cecc0
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
GTDDMURREP
gprsTddMultiratReporting
This parameter indicates the number TDD UTRAN cells to include in the measurement
report by gprs_attached mobile.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GTEMPOFF
gprsTemporaryOffset
This attribute applies a negative offset to C31 for the duration of
GPRS_PENALTY_TIME.
The 7 value means infinity; the step size for values between 1 and 6 is 10 dB.
Validity Range
Default Value
1 and <NULL> for ADJC object only
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
GTS
gprsTimeSlot
TRUE
FALSE
FALSE
0 - 3 (step 1)
2
0 - 7
<NULL>


1782 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecc0
g
This parameter defines the 64 kbit/s time slots reserved for this specific FRL either on A
interface or on G interface as specified with parameter GLK.
Even though the parameter consists of a list of max 31 values two different cases are
foreseen: in case of PCU equipped with PPXU boards up to 31 timeslots can be defined
on Gb interface for each PCM line.
The values must be separated by character &.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
GTXINT
gprsTxInterval
This parameter defines the number of slots to spread transmission of the random access
on PRACH channel.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
GUARMABIS
guaranteedMinimumAbis
This attribute specifies the minimum percentage of in service Abis subslots of the Abis
pool (configured on BTSM basis) at disposal of a cell (BTS).
When allocating new Abis resources in any cell X of a site the system guarantees that
the percentage of Abis subslots still idle and in service after the Abis allocation in the cell
X is equal or greater than GUARMABISy - %BusyAbisy, for every cell Y in the site
where:
(GUARMABISy != 0) and (%BusyAbisy <= GUARMABISy).
%BusyAbisy is the percentage of Abis subslots allocated to the cell Y, calculated with
respect to the total number of in service Abis subslots of the Abis pool.
GUARMABIS is guaranteed under normal conditions. It is not
guaranteed:
1 to 31 items of
1 - 31 Tsl1&Tsl2&...Tsl31
0 - 15
3


A30808-X3247-M230-6-7619

1783
CML:BSC g
Id:0900d805800cecc0
1) in case a fault or an operator command causes the outage of service of part of or all
the Abis subslots in the Abis pool, as long as the other cells of the site keep allocated
most of the residual in service Abis resources.
2) temporarily, after a reconfiguration that reduces the Abis pool size.
3) in case the Abis pool is heavily undersized with respect to the radio configuration.
Validity Range
Default Value
0
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
GUMTSSRHPRI
gprsUmtsSearchPriority
This parameter indicates if mobile gprs_attached can search 3G cells when BSIC
decoding is required, i.e. if the searching time can be longer than normal value ( 13 sec.
Instead of 10 sec. ).
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
0 - 20
<NULL>
TRUE
FALSE
TRUE


1784 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
h
HANDROR
handoverDropRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
HANFAIR
handoverFailureRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
HCICN
hCICN
High part of the CIC. This field identifies one among several 2 Mbit/s lines interconnect-
ing MSC and BSS.
Validity Range
Default Value
pcman
Pathname
<NULL>
NULL
Pathname
<NULL>
NULL
0 - 2729 0..2047 if CICFM = GSM
0..2729 if CICFM = NOTSTRUCT


A30808-X3247-M230-6-7619

1785
CML:BSC h
Id:0900d805800d5336
Contained in the following commands:
CREATE PCMA, GET PCMA
HDCFS
historyDroppedCallFileSize
This attribute represents the maximum size in Mbyte of the HDCTR logfile.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
HDCFUPE
historyOnDroppedCallsFileUploadPeriod
This attribute represents the upload of HDCTR file. The value 0 indicates no periodic
automatic upload.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
HEADER
header
This parameter defines the defines the software load header file.
1 - 12
1
upPe0h (0)
upPe1h (1)
upPe2h (2)
upPe3h (3)
upPe4h (4)
upPe6h (6)
upPe8h (8)
upPe12h (12)
upPe24h (24)
upPe0h


1786 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
The user can defines the header either typing the string in the field HEADER FILE or
using the button "Browse File".
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RSUEXE
HIERC
enableHierarchicalCellHo
The attribute indicates whether the ranking of the target cells based on the priority layer
is enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HIERF
hierarchicalCellRankFlag
The attribute is used to switch between two alternative ranking methods in case of
imperative handover.
1..59 characters string
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1787
CML:BSC h
Id:0900d805800d5336
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOAVDIST
hoAveragingDistance
This attribute defines the averaging window size for timing advance values (absolute
MS-BTS distance), used for handover decision.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOAVLEV
hoAveragingLev
This attribute defines two averaging parameters for the uplink and downlink signal
strength measurements, used for handover decision.
Rank0 All cells where rxlev_ncell > rxLevMinCell + max(0,PA)
are sorted in increasing order of priority where PBGT -
hoMargin > 0, followed by those cells where PBGT -
hoMargin < 0 in increasing order of priority. Having the
same priority the cells are sorted by PBGT - hoMargin.
Rank1 All cells where rxlev_ncell > rxLevMinCell + max(0,PA)
are subdivided into two sublists:
1. The upper sublist consists of all cells with:
rxlev_ncell > rxLevMinCell+max(0,PA)+ levelOffsetNcell
2. The lower sublist consists of all cells with:
rxlev_ncell <= rxLevMinCell+max(0,PA)+ levelOffset-
Ncell.
Within each sublist the cells are ordered according to their
priority. Cells with the same priority are ordered according
to the value of PBGT - hoMargin.
Rank0
1 - 31 of 1 SACCH multiframe (step size 1)
8


1788 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOAVPWRB
hoAveragingPowerBudget
This attribute defines the averaging window size, in SACCH periods, used for power
budget evaluation.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOAVQUAL
hoAveragingQual
This attribute defines two averaging parameters for the uplink and downlink signal
quality measurements, used for handover decision.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
size 1 - 31 (unit of 1 SACCH multiframe, step size 1)
weight 1 - 3 (step size 1)
size 4
weight 2
1 - 31 (1 SACCH multiframe step size)
8
size 1 - 31 (unit of 1 SACCH multiframe, step size 1)
weight 1 - 3 (step size 1)
size 3
weight 2


A30808-X3247-M230-6-7619

1789
CML:BSC h
Id:0900d805800d5336
HOCCDIST
hoConcentricCellDistance
Values are expressed in km.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOLTHLVDL
hoLowerThresholdLevDL
This attribute defines the receive signal strength threshold on downlink for intercell
handover decision.
Values expressed in dBr.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOLTHLVUL
hoLowerThresholdLevUL
This attribute defines the receive signal strength threshold on uplink for intercell
handover decision. Values expressed in dBr.
This attribute specifies the distance limit between inner and
complete area of a concentric cell which is taken into account for the
intracell handover in addition to the attribute HORXLVDLI respec-
tively
HORXLVDLO:
In case of TRX belonging to the inner area of a concentric cell the
additional 'or' condition 'distance > HOCCDIST is evaluated.
In case of a TRX belonging to the complete area of a concentric cell
the additional 'and' condition 'distance < HOCCDIST is evaluated.
0 - 35
5
0 - 63 For the values make references to Appendix B: Group 2.
10


1790 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOLTHQAMRDL
hoLowerThresQualAMRDL
This parameter determines the lower downlink quality handover threshold for AMR calls.
In case of an AMR call HOLTHQAMRDL eclipses the threshold HOLTHQUDL, i.e. for
AMR calls the handover algorithm triggers a handover due to quality downlink if the
quality drops below the threshold determined by HOLTHQAMRDL. As HOLTHQAMRDL
is entered in C/I values, but the MS reports the serving cell quality in form of RXQUAL
values, the BTS performs an internal mapping of RXQUAL to C/I values prior to the
downlink quality handover decision.
Validity Range
Default Value
8
Contained in the following commands:
GET HAND, SET HAND
HOLTHQAMRUL
hoLowerThresQualAMRUL
This parameter determines the lower uplink quality handover threshold for AMR calls. In
case of an AMR call HOLTHQAMRUL eclipses the threshold HOLTHQUUL, i.e. for AMR
calls the handover algorithm triggers a handover due to quality uplink if the quality drops
below the threshold determined by HOLTHQAMRUL.
As HOLTHQAMRUL is entered in C/I values, but the BTS measures the serving cell
quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL
to C/I values prior to the uplink quality handover decision.
Validity Range
Default Value
8
0 - 63 For the values make references to Appendix B: Group 2.
8
0 - 20 (1 dB step size)
<NULL>
0 - 20 (1 dB step size)
<NULL>


A30808-X3247-M230-6-7619

1791
CML:BSC h
Id:0900d805800d5336
Contained in the following commands:
GET HAND, SET HAND
HOLTHQUDL
hoLowerThresholdQualDL
This attribute defines the receive signal quality threshold on downlink for intercell
handover decision.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOLTHQUUL
hoLowerThresholdQualUL
This attribute defines the receive signal quality threshold on uplink for intercell handover
decision.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOM
hoMargin
The value of this attribute is used as a threshold to prevent repetitive hand-over between
adjacent cells, should the handover be caused by received signal level or the power
budget process.
The set value ranges from -63 dB to +63 dB (1 dB step size). Default value 69 corre-
sponds to 6 dB.
0 - 7 For the values make references to Appendix B: Group 3.
5
0 - 7 For the values make references to Appendix B: Group 3.
5


1792 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
HOMDOFF
hoMarginDynamicOffset
This parameter is only relevant for speed sensitive handover.
It specifies the dynamic offset by which the handover margin is reduced after expiry of
the timer HOMDTIME. Values expressed in dB.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
HOMDTIME
hoMarginDelayTime
This parameter is relevant for speed sensitive handover; it specifies the time an imme-
diate handover request is delayed when a power budget handover is requested.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
HOMRGTA
hoMarginTa
0 - 126
69
0 - 127 (1 dB step size)
0
0 - 255 (1 SACCH multiframe step size)
0


A30808-X3247-M230-6-7619

1793
CML:BSC h
Id:0900d805800d5336
This attribute specifies the threshold for the maximum timing advance in a single
timeslot. Values expressed in km.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOMSOFF
hoMarginStaticOffset
This parameter is only relevant for speed sensitive handover;
it specifies the static offset by which the handover margin is increased as long as the
timer HOMDTIME runs.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
HOMSTAM
hoMsTaMax
This attribute specifies the maximum allowed MS-BTS distance to use a single timeslot
channel. Values expressed in km.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOPMODE
hoppingMode
0 - 35
4
0 - 127 (1 dB step size)
0
0 - 34
32


1794 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
This attribute indicates whether baseband hopping or synthesizer hopping is to be done.
Validity Range
Default Value
BBHOP
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HOPP
enableHopping
For value FALSE: frequency hopping is not used.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HORXLVDLI
hoRxLevDLinner
This attribute defines the receive signal strength threshold on downlink which is evalu-
ated for the intracell handover from a TRX belonging to the inner area to a TRX belong-
ing to the complete area of a concentric cell. Values expressed in dBr.
Please refer to the description of HORXLVDLO parameter for furhter information.
BBHOP
SYNHOP
This attribute specifies whether frequency hopping is enabled or not.
The actual frequency hopping status is reported in the field BTS IS
HOPPING (refer to GETINFO BTS command).
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1795
CML:BSC h
Id:0900d805800d5336
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HORXLVDLO
hoRxLevDLouter
This attribute defines the receive signal threshold level on downlink which is evaluated
for the intracell handover from a TRX belonging to the complete area to a TRX belonging
to the inner area of a concentric cell. Values expressed in dBr.
To avoid 'ping pong' handovers between inner and complete area the following rule
should be followed:
HORXLVDLO - HORXLVDLI > (PWRREDinner - PWRREDcomplete) + HOM [dB]
where
HOM = margin to avoid ping-pong HO due to fading,
suggested value = default value of parameter HOM (ADJC object).
This rule is relevant for single-band concentric cells, as in such configurations the
coverage difference between inner and complete area is controlled by the PWRRED
parameter (see command CREATE TRX). The additional margin must be applied as a
kind of 'hysteresis' which avoids ping-pong handovers due to fading effects, i.e. han-
dovers that might occur due to normal level variations even when the subscriber remains
in a stationary position on the border between inner and complete area. It is not neces-
sary to use the default value of HOM (power budget handover margin, see command
SET ADJC) for this calculation, but it makes sense to assume the HOM default value as
a suitable default setting.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOSYNC
handoverSynchronization
This attribute is a flag to enable/disable the synchronized handover between cells
belonging to the same site.
0 - 63 For the values make reference to Appendix B: Group 2.
26
0 - 63 For the values make reference to Appendix B: Group 2.
32


1796 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
HOTDLINT
hoThresholdLevDLintra
This attribute defines the receive signal strength threshold on downlink for intracell
handover decision. Values expressed in dBr.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOTHAMRCDL
hoThresAMRComprDL
This parameter represents the downlink quality threshold used to trigger an intracell
AMR Compression Handover "fullrate to halfrate". The purpose of this handover is to
transfer AMR calls with excellent speech quality that currently occupy an AMR FR TCH
to an AMR HR TCH in order to use the TCH resources more efficiently. AMR compres-
sion handover (AMR fullrate to AMR halfrate) is triggered only if both the thresholds for
UL quality and DL quality (HOTHAMRCDL and HOTHAMRCUL) are exceeded.
As HOTHAMRCDL is entered in C/I values, but the MS reports the serving cell quality
in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I
values prior to the AMR compression handover decision.
Validity Range
Default Value
18
Contained in the following commands:
GET HAND, SET HAND
NONSYNC
SYNC
NONSYNC
0 - 63 For the values make references to Appendix B: Group 2.
35
0 - 20 (1 dB step)
<NULL>


A30808-X3247-M230-6-7619

1797
CML:BSC h
Id:0900d805800d5336
HOTHAMRCUL
hoThresAMRComprUL
This parameter represents the uplink quality threshold used to trigger an intracell AMR
Compression Handover "fullrate to halfrate". The purpose of this handover is to transfer
AMR calls with excellent speech quality that currently occupy an AMR FR TCH to an
AMR HR TCH in order to use the TCH resources more efficiently. AMR compression
handover (AMR fullrate to AMR halfrate) is triggered only if both the thresholds for UL
quality and DL quality
(HOTHAMRCDL and HOTHAMRCUL) are exceeded.
As HOTHAMRCUL is entered in C/I values, but the BTS measures the serving cell
quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL
to C/I values prior to the AMR compression handover decision.
Validity Range
Default Value
18
Contained in the following commands:
GET HAND, SET HAND
HOTHAMRDDL
hoThresAMRDecomprDL
This parameter represents the downlink quality threshold used to trigger an intracell
AMR Decompression Handover "halfrate to
fullrate". The purpose of this handover is to transfer AMR calls with poor speech quality
that currently occupy an AMR HR TCH to an AMR FR TCH in order to improve the
speech quality. In contrast to the intracell AMR compression handover (see parameter
HOTHAMRCDL), the Intracell AMR decompression handover "halfrate to fullrate" is trig-
gered if either the DL quality drops below the threshold HOTHAMRDDL or the UL quality
drops below the threshold HOTHAMRDUL. As HOTHAMRDDL is entered in C/I values,
but the MS reports the serving cell quality in form of RXQUAL values, the BTS performs
an internal mapping of RXQUAL to C/I values prior to the AMR decompression handover
decision.
Validity Range
Default Value
13
Contained in the following commands:
GET HAND, SET HAND
0 - 20 (1 dB step size)
<NULL>
0 - 20 (1 dB step)
<NULL>


1798 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
HOTHAMRDUL
hoThresAMRDecomprUL
This parameter represents the uplink quality threshold used to trigger an intracell AMR
Decompression Handover "halfrate to fullrate". The purpose of this handover is to
transfer AMR calls with poor speech quality that currently occupy an AMR HR TCH to
an AMR FR TCH in order to improve the speech quality. In contrast to the intracell AMR
compression handover (see parameter HOTHAMRCUL), the Intracell AMR decompres-
sion handover "halfrate to fullrate" is triggered if either the DL quality drops below the
threshold HOTHAMRDDL or the UL quality drops below the threshold HOTHAMRDUL.
As HOTHAMRDUL is entered in C/I values, but the BTS measures the serving cell
quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL
to C/I values prior to the AMR decompression handover decision.
Validity Range
Default Value
13
Contained in the following commands:
GET HAND, SET HAND
HOTHCMPLVDL
hoThresComprLevDL
This attribute defines the downlink condition for triggering a compression handover.
Validity Range
Default Value
40
Contained in the following commands:
GET HAND, SET HAND
HOTHCMPLVUL
hoThresComprLevUL
This attribute defines the uplink condition for triggering a compression handover.
0 - 20 (1 dB step)
<NULL>
0 - 63 (step 1 dBm ) (0 = -110 dBm, 63 = 48 dBm)
<NULL>


A30808-X3247-M230-6-7619

1799
CML:BSC h
Id:0900d805800d5336
Validity Range
Default Value
40
Contained in the following commands:
GET HAND, SET HAND
HOTHDCMLVDL
hoThresDecomprLevDL
This attribute defines the downlink condition for triggering a decompression handover.
Validity Range
Default Value
26
Contained in the following commands:
GET HAND, SET HAND
HOTHDCMLVUL
hoThresDecomprLevUL
This attribute defines the uplink condition for triggering a decompression handover.
Validity Range
Default Value
26
Contained in the following commands:
GET HAND, SET HAND
HOTHEFRCDL
hoThresholdEFRComprDL
Downlink threshold for C/I threshold for compression handover from EFR to GSM HR.
0 - 63 (1 dB step) (0 = -11 dBm, 63 = 48 dBm)
<NULL>
0 - 63 (step 1 dBm) (0 = -110 dBm, 63 = 48 dBm)
<NULL>
0 - 63 (step 1 dBm) (0 = -110 dBm, 63 = 48 dBm)
<NULL>


1800 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
18
Contained in the following commands:
GET HAND, SET HAND
HOTHEFRCUL
hoThresholdEFRComprUL
Uplink threshold for C/I threshold for compression handover from EFR to GSM HR.
Validity Range
Default Value
18
Contained in the following commands:
GET HAND, SET HAND
HOTHFRCDL
hoThresholdFRComprDL
Downlink threshold for C/I threshold for compression handover from GSM FR to GSM
HR.
Validity Range
Default Value
18
Contained in the following commands:
GET HAND, SET HAND
HOTHFRCUL
hoThresholdFRComprUL
Uplink threshold for C/I threshold for compression handover from GSM FR to GSM HR.
0 - 20 (1 dBm step)
<NULL>
0 - 20 (step 1 dBm)
<NULL>
0 - 20 (1 dBm step)
<NULL>


A30808-X3247-M230-6-7619

1801
CML:BSC h
Id:0900d805800d5336
Validity Range
Default Value
18
Contained in the following commands:
GET HAND, SET HAND
HOTHHRDDL
hoThresholdHRDecomprDL
Downlink threshold for C/I threshold for decompression handover from GSM HR to EFR
respectively to GSM FR.
Validity Range
Default Value
13
Contained in the following commands:
GET HAND, SET HAND
HOTHHRDUL
hoThresholdHRDecomprUL
Uplink threshold for C/I threshold for decompression handover from GSM HR to EFR
respectively to GSM FR.
Validity Range
Default Value
13
Contained in the following commands:
GET HAND, SET HAND
HOTMSRM
hoThresholdMsRangeMax
This attribute specifies the maximum allowed MS-BTS distance for the current cell.
0 - 20 (1 dBm step)
<NULL>
0 - 20 (1 dBm step)
<NULL>
0 - 20 (1 dBm step)
<NULL>


1802 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOTMSRME
hoThresholdMsRangeMaxExt
This attribute specifies the maximum allowed MS-BTS distance for the extended cell.
Default value expressed in km.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HOTULINT
hoThresholdLevULintra
This attribute defines the receive signal strength threshold on uplink for intracell
handover decision. Values expressed in dBr.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
HRACTAMRT1
hRActivationAmrThreshold1
This parameter is the threshold that indicates, in case of AMR calls, the percentage of
busy TCHs in case of standard cell or complete area of a concentric cell or far area of
an extended cell.
0 - 35 (1 km step size)
34
35 - 100 (1 km step size)
99
0 - 63
35


A30808-X3247-M230-6-7619

1803
CML:BSC h
Id:0900d805800d5336
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HRACTAMRT2
hRActivationAmrThreshold2
This parameter is the threshold that indicates, in case of AMR calls, the percentage of
busy TCHs in case of inner area of a concentric cell or near area of an extended cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HRACTT1
hRActivationThreshold1
This parameter is the threshold that indicates the percentage of busy TCHs in case of
standard cell or complete area of a concentric cell or far area of an extended cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HRACTT2
hRActivationThreshold2
This parameter is the threshold that indicates the percentage of busy TCHs in case of
inner area of a concentric cell or near area of an extended cell.
0 - 10000
6000
0 - 10000
6000
0 - 10000
6000


1804 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HRDATA
halfRateDataSupported
This read-only parameter defines whether the half rate data service is supported or not.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET BSC
HRDCMLIMTH
hRDecomprLimitThreshold
Threshold for limitation of load dependent decompression handover on those connec-
tions that fulfill the following rule:
[(C/I)i + PRi - hoThresccDecomprxxi] < hRDecomprLimitThres dB
Validity Range
Default Value
6
Contained in the following commands:
GET HAND, SET HAND
HRSPEECH
halfRateSpeechSupported
This attribute controls the Half Rate Speech service activation.
0 - 10000
6000
TRUE
FALSE
0 - 100 (1 dBm step size)
<NULL>


A30808-X3247-M230-6-7619

1805
CML:BSC h
Id:0900d805800d5336
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
HSCSDLLCOM
hscsLayerListComplementary
This parameter defines the list of TRX layers assigned to Circuit Switch Multislot calls
using HSCSD in the inner/near area of dual area cell (extended, concentric single/dual
band), or in the complementary band of a dual band standard cell. The TRX layers are
specified in the list in a decreasing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HSCSDLLPRM
hscsdLayerListPrimary
TRUE
FALSE
FALSE
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


1806 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5336
h
This parameter defines the list of TRX layers assigned to Circuit Switch Multislot calls
using HSCSD in a single band standard cell, or in the complete/far area of a dual area
cell (extended, concentric single/dual band), or in the BCCH band of a dual band
standard cell. The TRX layers are specified in the list in a decreasing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
HSN
hoppingSequenceNumber
It determines the sequence in which the hopping is done. When HSN = 0 a cyclic
hopping sequence is used, else the value is used as a generator value for pseudo
random hopping sequence.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CFHSY, CREATE FHSY, GET CFHSY, GET FHSY, SET CFHSY, SET
FHSY
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL
0 - 63


A30808-X3247-M230-6-7619

1807
CML:BSC i
Id:0900d805800d1c88
i
IDBSCESUDB
identifierBSCESUDB
This parameter defines the identifier of the BSC Executable Software Unit DB; it consists
of two fields but only one can be used (NAME or USER LABEL DB).
The BSCESUDB validity range is 0..19.
Validity Range
In commands GET BSCESUDB, GET BSCESUDB STAT, GETINFO BSCESUDB:
In commands SET BSCOSUDB:
Default Value
None.
Contained in the following commands:
GET BSCESUDB, GET BSCESUDB STAT, GETINFO BSCESUDB, SET
BSCOSUDB
IDBSCESUSW
identifierBSCESUSW
This parameter defines the identifier of the BSC Executable Software Unit SW; it
consists of two fields but only one can be used (NAME or USER LABEL SWLH).
The BSCESUSW validity range is 0..19.
Validity Range
In commands GET BSCESUSW, GET BSCESUSW STAT, GETINFO BSCESUSW:
In commands SET BSCOSUSW:
Name Pathname (e.g. BSCESUDB:0)
UserLabel 1..30 characters
string
characters string
Name Pathname
UserLabel 1..30 characters
string
Name Pathname (e.g. BSCESUSW:0)
UserLabel 1..30 characters
string
characters string
Name Pathname
UserLabel 1..30 characters
string


1808 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
Default Value
None.
Contained in the following commands:
GET BSCESUSW, GET BSCESUSW STAT, GETINFO BSCESUSW, SET
BSCOSUSW
IDNEYESUSW
identifierNEYESUSW
This parameter defines the identifier of the Executable Software Unit SW for the NE; it
consists of two fields but only one can be used (NAME or Label Access).
The NEYESUSW validity range is 0..39.
The BTSEC is not supported.
Validity Range
Default Value
None.
Contained in the following commands:
GET NEYESUSW, GET NEYESUSW STAT, GETINFO NEYESUSW
IDRSUDB
identifierRSUDB
This parameter defines the identifier of the Replaceable Software Unit DataBase; it
consists of two fields but only one can be used (NAME or USER LABEL DB).
The RSUDB validity range is 0..19.
Validity Range
In commands UPLDFILE RSUDB:
In commands DELETE RSUDB, GET RSUDB, GET RSUDB STAT, SET RSUDB:
name Pathname (e.g. NEYESUSW:0)
userLabel 1..30 characters
string
networkElement BTSE
TRAUE
BTSEC
Name Pathname
UserLabel 1..30 characters
string
Name Pathname (e.g. RSUDB:0)


A30808-X3247-M230-6-7619

1809
CML:BSC i
Id:0900d805800d1c88
Default Value
None.
Contained in the following commands:
DELETE RSUDB, GET RSUDB, GET RSUDB STAT, SET RSUDB, UPLDFILE
RSUDB
IDRSUEXE
identifierRSUEXE
This parameter defines the identifier of the Replaceable Software Unit Executable; it
consists of two fields but only one can be used (NAME or Label Access).
The user can defines the RELATED FILES either typing the string in the related field or
using the button "Browse File".
The RSUSWLH validity range is 0..59 and the RSUEXE validity range is 0..259.
UserLabel 1..30 characters
string


1810 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
Validity Range
Default Value
None.
Name Pathname (e.g. RSUSWLH:0/RSUEXE:0)
UserLabelSwLH 1..30 characters
string
ProcessorType SWLH
IXLT
PPCU
PPCC
PPLD
TDPC
BSCI
MSCI
DSP
ACTAM
ALCO
BBSIG
CCTRL
CCLK
LI
TRXA
TRAC
TRXD
VAMBSC
VAMBTSE
VAMTRAU
PPXL
PPXU
MPCC
GENERICEXE
PPXP
PPXT
VAMBTSC
GENERICBTSC
RelatedFiles 1..59 characters
string


A30808-X3247-M230-6-7619

1811
CML:BSC i
Id:0900d805800d1c88
Contained in the following commands:
DELETE RSUEXE, GET RSUEXE, GET RSUEXE STAT
IDRSUPCH
identifierRSUPCH
This parameter defines the identifier of the Replaceable Software Unit Patch; it consists
of two fields but only one can be used (NAME or Label Access).
The RSUSWLH validity range is 0..59, the RSUEXE validity range is 0..259 and the
RSUPCH validity range is 0..199.
Validity Range
Default Value
None.
Contained in the following commands:
DELETE RSUPCH, GET RSUPCH, GET RSUPCH STAT, LOADPATCH RSUPCH,
SET RSUPCH, UNLOADPCH RSUPCH
IDRSUSWLH
identifierRSUSWLH
This parameter defines the identifier of the Replaceable Software Unit SW Load
Headers; it consists of two fields but only one can be used (NAME or Label Access).
The RSUSWLH validity range is 0..59.
The BTSEC is not supported.
Name Pathname (e.g. RSUSWLH:0/RSUEXE:0/RSUPC:0)
UserLabelSwLH 1..30 characters
string
UserLabelPch 1..30 characters
string
ProcessorType PPCU
TDPC
PPXL
PPXU
MPCC
PPXP
PPXT


1812 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
Validity Range
Default Value
None.
Contained in the following commands:
DELETE RSUSWLH, GET RSUSWLH, GET RSUSWLH STAT, SET RSUSWLH
IERCHOSDCCH
enableInterCellHoSdcch
This attribute allows a managing system to enable or disable inter cell handovers for
SDCCH channels.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET HAND, SET HAND
IMCSULNIR8PSK
initialMcsUplinkWoutIncrRed8psk
This parameter suggests the MCS to be used in an EDGE TBF if no other information
about that MS in that BVC is available. This
parameter can be used if MS is an 8PSK MS and Incremental
Redundancy is not usable in the BVC and no other information is available about that
MS.
Name Pathname (e.g. RSUSWLH:0)
UserLabelSwLH 1..30 characters
string
NetworkElement BSC
BTSE
TRAUE
BTSEC
TRUE
FALSE
<NULL>


A30808-X3247-M230-6-7619

1813
CML:BSC i
Id:0900d805800d1c88
Validity Range
Default Value
MCS3
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
IMCSULNIRGMSK
initialMcsUplinkWoutIncrRedGmsk
This parameter suggests the MCS to be used in an EDGE TBF if no other information
about that MS in that BVC is available. This
parameter can be used if MS is a GMSK MS, Incremental
Redundancy is not usable in the BVC and no other information is available about that
MS.
Validity Range
Default Value
MCS3
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
IMMASSFAIR
immediateAssignmentFailureRate
MCS1
MCS2
MCS3
MCS4
MCS5
MCS6
MCS7
MCS8
MCS9
<NULL>
MCS1
MCS2
MCS3
MCS4
<NULL>


1814 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
IMSIATDT
allowImsiAttachDetach
This attribute controls whether the IMSI attach/detach procedure is used in the cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
IMSIFSIZ
imsiFileSize
The attribute specifies the maximum file size (in Mbytes) for IMSI files.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
INIBLER
initialBLER
Pathname
<NULL>
NULL
TRUE
FALSE
TRUE
0 - 30
30


A30808-X3247-M230-6-7619

1815
CML:BSC i
Id:0900d805800d1c88
This attribute defines the initial BLER estimation in a cell to be used in Resource Man-
agement to calculate the initial number of radio resources to be assigned to packet ser-
vices, when no 'historical'
information about BLER is available.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
INICSCH
initialCodingScheme
This parameter indicates the coding scheme to be used when the packet transfer starts.
The value is used only if no other information about optimum coding scheme is avail-
able.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
INIMCSDL
initialMcsDownlink
PER10
PER20
PER30
PER40
PER50
PER60
PER70
PER80
PER90
PER10
CS1
CS2
CS3
CS4
CS2


1816 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
This parameter suggests the MCS to be used in an EDGE TBF if no other information
about that MS in that BVC is available. This
parameter can be used if MS is a GMSK MS, Incremental
Redundancy is not usable in the BVC and no other information is available about that
MS.
Validity Range
Default Value
MCS6
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
ININHO
enableInnerInnerHo
The attribute enables/disables the intercell handover from inner to inner area in sector-
ized concentric cells
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
MCS1
MCS2
MCS3
MCS4
MCS5
MCS6
MCS7
MCS8
MCS9
<NULL>
TRUE
FALSE
TRUE


A30808-X3247-M230-6-7619

1817
CML:BSC i
Id:0900d805800d1c88
INITLEV
initLevel
Validity Range
Default Value
None.
Contained in the following commands:
SYSINIT SYSINIT
INSTANCE
instance
This attribute specifies the instance of the Network Element (TRAU or BTSE) which the
upload of the log file is related to.
Validity Range
In commands UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG
SOFTWARE-MANAGEMENT:
In commands UPLTRAULOG SOFTWARE-MANAGEMENT:
This attribute defines the initialization level. Each level provides cor-
rection actions and should be applied when hardware and
software faults cause a system to have an unstable or non correct
behaviour. The following levels are provided:
BU_ACTIVE
The initialization is performed at the highest level; it is used
by the system when starting a "bring_up".
FULL
The initialization involves the processor memory and the
hardware. It forces the release of all connections.
TASK_PRIME
The lower level initializations involve all connections.
Prime/Start activities which are restarted. Processor memory
and hardware are partially initialized. Connections which are
in steady state (talking subscribers) are preserved.
BU_ACTIVE
FULL
TASK_PRIME
0 - 199
0 - 47


1818 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
Default Value
None.
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG SOFTWARE-MAN-
AGEMENT, UPLTRAULOG SOFTWARE-MANAGEMENT
INTAVEPR
interferenceAveragingProcess
Default values are referred respectively to: averPeriod, intThrBou, intThrBou2,
intThrBou3 and intThrBou4.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
INTCLASS
enableInterferenceClass
This attribute contains two parameters used in averaging the
interference levels in the unallocated time slots.
averagingPeriod indicates the number of SACCH multiframes over
which the values are averaged.
interferenceThresholdBoundaries<n> (with <n> from 1 to 4) indi-
cates boundary limits of four interference bands for the unallocated
time slots.
The BSS shall map the averaged interference level measurements
into these five bands.
averPeriod 1 - 31
intThrBou1 0 - 62
intThrBou2 0 - 62
intThrBou3 0 - 62
intThrBou4 0 - 62
31
2
6
12
22


A30808-X3247-M230-6-7619

1819
CML:BSC i
Id:0900d805800d1c88
This attribute defines whether the interference classification of idle traffic channels is
enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
INTCTMST
integratedCellularTelephoneModemStatus
This attribute enables/disables the integrated CTM feature.
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
INTERCH
enableInterCellHo
This attribute allows a managing system to enable or disable inter cell handovers for
TCH channels in BTS.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
TRUE
FALSE
TRUE
disabled
enabled
disabled
TRUE
FALSE
FALSE


1820 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
INTINF
interfaceInformation
This parameter identifies the logic interface towards the alarm
detection equipment.
Validity Range
Default Value
Contained in the following commands:
CREATE ENVA, GET ENVA, SET ENVA
INTRACH
enableIntraCellHo
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
INTRTRFH1TODIFFSERV
interactiveTrafficHandlingPrio1ToDiffserv
This attribute represents the mapping between interactive class with traffic handling 1
and DSCP coding.
low
high
high
This attribute allows a managing system to enable or disable intracell
handovers for TCH channels in BTS.
The attribute is meaningless when the cell is concentric.
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1821
CML:BSC i
Id:0900d805800d1c88
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
INTRTRFH1WEI
interactiveTrafficHandlingPrio1Weight
This attribute represents the weight for class, traffic handling priority 1 (scheduling
priority 1).
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
INTRTRFH2TODIFFSERV
interactiveTrafficHandlingPrio2ToDiffserv
This attribute represents the mapping between interactive class with traffic handling 2
and DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
INTRTRFH2WEI
interactiveTrafficHandlingPrio2Weight
This attribute represents the weight for class, traffic handling priority 2 (scheduling
priority 2).
0 - 63
0
1 - 32
8
0 - 63
0


1822 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c88
i
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
INTRTRFH3TODIFFSERV
interactiveTrafficHandlingPrio3ToDiffserv
This attribute represents the mapping between interactive class with traffic handling 3
and DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
INTRTRFH3WEI
interactiveTrafficHandlingPrio3Weight
This attribute represents the weight for class, traffic handling priority 3 (scheduling
priority 3).
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
IPADDR
ipAddress
This attribute represents a well known IP address of an external equipment that should
be reached by the BSC using a ping operation.
1 - 32
4
0 - 63
0
1 - 32
2


A30808-X3247-M230-6-7619

1823
CML:BSC i
Id:0900d805800d1c88
Validity Range
Default Value
None.
Contained in the following commands:
PING IPLI
IRACHOSDCCH
enableIntraCellHoSdcch
This attribute allows a managing system to enable or disable intracell handovers for
SDCCH channels.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET HAND, SET HAND
7..15 characters string
TRUE
FALSE
<NULL>


1824 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
l
L1CTS
layer1ControlTimeslot
It defines the layer 1 dedicated 16kbit/s subchannel used for
supervision in case of LOOP configuration.


A30808-X3247-M230-6-7619

1825
CML:BSC l
Id:0900d805800d5339
Validity Range
Tsl TSL_1
TSL_2
TSL_3
TSL_4
TSL_5
TSL_6
TSL_7
TSL_8
TSL_9
TSL_10
TSL_11
TSL_12
TSL_13
TSL_14
TSL_15
TSL_16
TSL_17
TSL_18
TSL_19
TSL_20
TSL_21
TSL_22
TSL_23
TSL_24
TSL_25
TSL_26
TSL_27
TSL_28
TSL_29
TSL_30
TSL_31
Ssl SSL_0
SSL_1
SSL_2
SSL_3


1826 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
Default Value
Tsl = TSL_1
Ssl = SSL_0
Contained in the following commands:
CREATE PCMB, GET PCMB, SET PCMB
L2PV
layer2ProtocolVariant
Protocol variant.
Validity Range
Default Value
ISO_7776
Contained in the following commands:
GET X25A, GET X25D
L2WIN
layer2WindowSize
Window size.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
L3PS
networkLayerPacketSize
Network Layer Packet Size.
NOT_DEFINED
<NULL>
ISO_7776
GENPDN
DDNTW
1 - 7
7


A30808-X3247-M230-6-7619

1827
CML:BSC l
Id:0900d805800d5339
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
L3PV
networkLayerProtocolVariant
Protocol Variant.
Validity Range
Default Value
ISO8208VER84
Contained in the following commands:
GET X25A, GET X25D
L3WIN
networkLayerWindowSize
Network Layer Window Size.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
Packet_128
Packet_256
Packet_512
Packet_1024
Packet_2048
Packet_4096
Packet_2048
ISO8208VER80
PDN1980
DDN1980
ISO8208VER84
1 - 7
7


1828 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
LAPDOVLT
lapdOverloadTimer
This parameter defines the overload indication period. Values are expressed in
seconds.
Validity Range
Default Value
10
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
LAPDPOOL
lapdPool
If the PPXLs are used, this attribute assumes the meaning of "primary PPXL" (i.e. the
PPXL where the LAPD must work if both PPXLs are in service). If case of NTWSN16
the LAPDPOOL value does not have any relationship with the instance of the physical
PPLDs equipped.
The operator, by means of this attribute, can define a group of LAPDs managed by the
same PPLD. If the operator does not set the attribute the value is assigned by the BSC.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE LPDLM, CREATE LPDLS, GET LPDLM, GET LPDLS, SET LPDLM, SET
LPDLS
LAYERID
layerIdentifier
This parameter specifies the group of radio resources to which the TRX belongs.
1 - 60
<NULL>
0 - 1


A30808-X3247-M230-6-7619

1829
CML:BSC l
Id:0900d805800d5339
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
LCBM<N>
localCellBroadcastMessage<n>
This attribute specifies the handling and the contents of the Local Cell Broadcast
Message.
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
ly_00


1830 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
Msgid 0 - 65534
Page 1..92 characters
string
RepRate SEC_0030
SEC_0060
SEC_0120
SEC_0240
SEC_0480
SEC_0960
SEC_1920
SEC_0010
SEC_0150
SEC_0002
SEC_0090
SEC_0180
SEC_0360
Scheme GERMAN
ENGLISH
ITALIAN
FRENCH
SPANISH
DUTCH
SWEDISH
DANISH
PORTUGUESE
FINNISH
NORWEGIAN
GREEK
TURKISH
UNSPECIFIED
<NULL>
NULL


A30808-X3247-M230-6-7619

1831
CML:BSC l
Id:0900d805800d5339
LCN2WC
lcnOf1st2WayChannels
LCN of 1st 2 Way Channels.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
LCNIOC
lcnOf1stIncomingOnly
This read-only parameter defines the LCN of first incoming only
channels, included in the X25A and X25D configuration message (IXLT restart).
Validity Range
Default Value
0
Contained in the following commands:
GET X25A, GET X25D
LCNOOC
lcnOf1stOutgoingOnly
This read-only parameter defines the LCN of first outgoing only
channels, included in the X25A and X25D configuration message (IXLT restart).
Validity Range
Default Value
0
Contained in the following commands:
GET X25A, GET X25D
0 - 4095
1
0 - 4095
0 - 4095


1832 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
LCSMONTH
lCSMonitorTresholds
Default values are referred respectively to: Minor, Major and Critical.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
LCSNSSC
lcsNssCentric
This parameter allows to choose the location service type (NSS centric / BSS centric)
supported by BSC.
If this parameter is set at TRUE, the BSC supports the NSS centric solution and all the
BSS requests are rejected, on the contrary if it is set at FALSE the BSC support the BSS
centric request and the NSS centric are rejected.
The LCSMONTH (LCS Monitor Thresholds) parameter indicates the
A-Int Monitor Thresholds for SS7 channels. The threshold is the per-
centage between out of service SS7S on equipped SS7S; that is:
LCSMONTH = (SS7S out of service/SS7S equipped)*100).
The threshold values can be assigned only when the flag attribute is
set to "enabled".
Minor Disabled 0 - 0
Enabled 1 - 100
Major Disabled 0 - 0
Enabled 1 - 100
Critical Disabled 0 - 0
Enabled 1 - 100
Enabled(30)-Enabled(60)-
Enabled(90)


A30808-X3247-M230-6-7619

1833
CML:BSC l
Id:0900d805800d5339
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
LEND
lengthData
This attribute identifies the number of BYTE, WORD or DWORD to read.
Validity Range
Default Value
None.
Contained in the following commands:
MEMDUMP BSC
LEVHOM
levelHOMargin
This parameter represents a threshold to guarantee a handover to a target cell with a
higher level than the serving cell, without altering the behaviour of the other handover
types.
The set value ranges from -63 dB to +63 dB. (1 dB step size).
Validity Range
Default Value
69 [6 dB]
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
LEVONC
levelOffsetNCell
TRUE
FALSE
FALSE
1 - 128
0 - 126
<NULL>


1834 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
The attribute defines the level offset that is added to the minimum receive level of an
adjacent cell to become a target cell in case the ranking method 1 is specified in the hier-
archicalCellRankFlag (object HAND).
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
LFID
listOfFileIds
This attribute defines the list of the file names that have to be compressed. It consists of
a list of 60 items; for each item, the "field" attribute has to be set.
Validity Range
Default Value
None.
Contained in the following commands:
FILECOM FILEHANDLER
LINKTYPE
linkType
This parameter indicates the type of the physical link used.
Validity Range
Default Value
Contained in the following commands:
CREATE CBCL, CREATE OMAL, GET CBCL, GET OMAL
0 - 63
0
1 to 60 items of
1..13 characters string (LFID1&LFID2&......)
X25A
X25D
IPLI
X25D


A30808-X3247-M230-6-7619

1835
CML:BSC l
Id:0900d805800d5339
LISOFMONOBJS
listOfMonitoredObjects
This parameter defines the object on which it is possible to enter the GetCurrentValues
command.
Validity Range
Default Value
None.
Contained in the following commands:
GETCURRENTVALUES SCANBTSIHO
LKSET
linkSet
This parameter defines the linkset number of SS7L link.
Validity Range
Default Value
0
Contained in the following commands:
CREATE SS7L, GET SS7L
LLCDVOLTRSH
lLCDataVolumeThreshold
This parameter allows the operator to set the minimum LLC data volume to be reached
to trigger the related PM counter. Values are expressed in kbit.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
2 to 2 items of
Pathname Scanner Object Class OBJ Format
SCANBTSIHO OBJ:BTSM:btsmn/BTS:btsn-
BTSM:btsmn/BTS:btsn
0 - 1
0 - 20
0


1836 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
LOCIPEP
localIPEndpoint
This parameter indicates the local IP endpoint.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE NSVLIP, GET NSVLIP, SET NSVLIP
LOGTYPE
Logtype
This parameter defines the log file type; two type of log file are
available: command responses and events log file.
Validity Range
Default Value
None.
Contained in the following commands:
UPLPRLOG FILEHANDLER
LOTERCH
enableLocalInterCellHo
This attribute allows a managing system to enable or disable BSC controlled inter cell
handovers. The attribute takes the following values: TRUE - BSC controlled inter cell
handovers are allowed, FALSE - BSC controlled inter cell handovers are not allowed
(the inter cell handovers are managed by MSC).
pcuPort 0 - 1
udpPort 1024 - 65535
CMDRSPLOG
EVTLOG


A30808-X3247-M230-6-7619

1837
CML:BSC l
Id:0900d805800d5339
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
LOTRACH
enableLocalIntraCellHo
This attribute allows a managing system to enable or disable BSC controlled intracell
handovers. If the attribute values TRUE the BSC controlled intracell handovers are
allowed, if it values FALSE the BSC controlled intracell handovers are not allowed (the
intracell handovers are managed by MSC).
Note that in case of Extended and Concentric cells the Intracell Handover is always
managed by the BSC and so this attribute value is meaningless.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
LOWBER
lowerBitErrorRate
This parameter defines the Lower Bit Error Rate value.
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE


1838 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
Validity Range
Default Value
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
LOWTLEVD
pcLowerThresholdLevDL
This attribute defines the lower threshold of the received signal level on downlink for
power increase. Values expressed in dBr.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
LOWTLEVU
pcLowerThresholdLevUL
This attribute defines the lower threshold of the received signal level on uplink for power
increase. Values expressed in dBr.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
E10_3
E10_4
E10_5
E10_6
E10_7
E10_8
E10_9
E10_3
0 - 63 For the values make references to Appendix B: Group 2.
25
0 - 63 For the values make references to Appendix B: Group 2.
25


A30808-X3247-M230-6-7619

1839
CML:BSC l
Id:0900d805800d5339
LOWTQUAD
pcLowerThresholdQualDL
This attribute defines the lower threshold of the received signal quality on downlink for
power increase.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
LOWTQUAMRDL
pcLowerThresQualAMRDL
This parameter determines the lower power control downlink quality threshold for AMR
calls. In case of an AMR call LOWTQUAMRDL eclipses the threshold LOWTQUAD, i.e.
for AMR calls the power control algorithm increases the DL transmit power if the quality
drops below the threshold determined by LOWTQUAMRDL.
As LOWTQUAMRDL is entered in C/I values, but the MS reports the serving cell quality
in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL to C/I
values prior to the power control decision.
Validity Range
Default Value
10 dB
Contained in the following commands:
GET PWRC, SET PWRC
LOWTQUAMRUL
pcLowerThresQualAMRUL
This parameter determines the lower power control uplink quality threshold for AMR
calls. In case of an AMR call LOWTQUAMRUL eclipses the threshold LOWTQUAU, i.e.
for AMR calls the power control algorithm increases the UL transmit power if the quality
drops below the threshold determined by LOWTQUAMRUL.
As LOWTQUAMRUL is entered in C/I values, but the BTS measures the serving cell
quality in form of RXQUAL values, the BTS performs an internal mapping of RXQUAL
to C/I values prior to the power control decision.
0 - 7 For the values make references to Appendix B: Group 3.
4
0 - 20 (1 dB step size)
<NULL>


1840 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
Validity Range
Default Value
10 dB
Contained in the following commands:
GET PWRC, SET PWRC
LOWTQUAU
pcLowerThresholdQualUL
This attribute defines the lower threshold for the received signal quality on uplink for
power increase.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
LPDLMN
lapdmNumber
This parameter indicates the "primary" position (pcmb number and TS LAPD number)
of the LPDLR links. This "primary" position identifies the physical LAPD link (LPDLM)
which the LPDLR link created is mapped to.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TRX, GET TRX
LPDLMSAT
lapdmLinkSatellited
This attribute indicates whether the LAPD link on the Abis interface is satellited or ter-
restrial.
0 - 20 (1 dB step size)
<NULL>
0 - 7 For the values make references to Appendix B: Group 3.
4
0 - 10


A30808-X3247-M230-6-7619

1841
CML:BSC l
Id:0900d805800d5339
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM
LREDUNEQ
lineRedundancyEquipped
Validity Range
In commands CREATE PCMB, CREATE PCMS, GET PCMB, GET PCMS:
In commands SET PCMB, SET PCMS:
Default Value
None.
Contained in the following commands:
CREATE PCMB, CREATE PCMS, GET PCMB, GET PCMS, SET PCMB, SET
PCMS
LSLOTIME
lastLockTime
This read-only parameter is the date of the last LOCK command.
It consists of the following fields: Day, Month, Year, Hour and Min.
TRUE
FALSE
FALSE
This attribute assumes three values depending on the three follow-
ing PCM line configurations:
- only trunk A is equipped (star or multidrop configuration)
- only trunk B is equipped (star or multidrop configuration)
- both trunk A and B are equipped (loop configuration)
SIMPLEXA
SIMPLEXB
DUPLEX
DUPLEX


1842 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
Validity Range
Default Value
None.
Contained in the following commands:
GET SCANBSC, GET SCANBTS, GET SCANBTSE, GET SCANBTSIHO, GET
SCANBTSM, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS,
GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET
SCANSS7L, GET SCANTRX
LSULOTIME
lastUnlockTime
This read-only parameter is the date of the last LOCK command.
It consists of the following fields: Day, Month, Year, Hour and Min.
day 1 - 31
month Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
year 1992 - 2099
hour 0 - 23
min 0 - 59
<NULL>


A30808-X3247-M230-6-7619

1843
CML:BSC l
Id:0900d805800d5339
Validity Range
Default Value
None.
Contained in the following commands:
GET SCANBSC, GET SCANBTS, GET SCANBTSE, GET SCANBTSIHO, GET
SCANBTSM, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS,
GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET
SCANSS7L, GET SCANTRX
LSUPDTIME
lastUpdTime
This read-only parameter is the date of the last configuration command (CREATE or
SET command).
It consists of the following fields: Day, Month, Year, Hour and Min.
day 1 - 31
month Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
year 1992 - 2099
hour 0 - 23
min 0 - 59
<NULL>


1844 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d5339
l
Validity Range
Default Value
None.
Contained in the following commands:
GET CTRSCHED, GET SCANBSC, GET SCANBTS, GET SCANBTSE, GET SCAN-
BTSIHO, GET SCANBTSM, GET SCANBTSOHOI, GET SCANBTSOHON, GET
SCANBTSOHOS, GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET
SCANGPRS, GET SCANSS7L, GET SCANTRX
LWWPSPRI
lowestWPSPriority
This attribute specifies the lowest Priority level to be considered in the WPS queue.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
day 1 - 31
month Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
year 1992 - 2099
hour 0 - 23
min 0 - 59
1 - 10
<NULL>
NULL


A30808-X3247-M230-6-7619

1845
CML:BSC m
Id:0900d805800d8729
m
M2T1
mtl2Timer1
"Alignment ready" timer.
Validity Range
Default Value
140 for ANSI and 450 for CCITT.
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M2T2
mtl2Timer2
"Not aligned" timer.
Validity Range
Default Value
100 for ANSI and CCITT.
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M2T3
mtl2Timer3
"Aligned" timer.
Validity Range
Default Value
10 for CCITT and 120 for ANSI.
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
129 - 500 129-160 hundreds of ms for ANSI
400-500 hundreds of ms for CCITT
50 - 1500 50 -300 hundreds of ms for ANSI
50 - 1500 hundreds of ms for CCITT
10 - 140 10-15 hundreds of ms for CCITT
50-140 hundreds of ms for ANSI


1846 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
M2T4E
mtl2Timer4E
Emergency proving period timer.
Validity Range
Default Value
5 for CCITT and 6 for ANSI
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M2T4N
mtl2Timer4N
Normal proving period timer.
Validity Range
Default Value
24 for ANSI and 80 for CCITT.
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M2T5
mtl2Timer5
SIB Sending timer.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M2T6
mtl2Timer6
Remote congestion timer.
4 - 7 4-7 hundreds of ms for ANSI
4-5 hundreds of ms for CCITT
15 - 95 15-30 hundreds of ms for ANSI
75-95 hundreds of ms for CCITT
1 - 2 (100 ms step size)
1


A30808-X3247-M230-6-7619

1847
CML:BSC m
Id:0900d805800d8729
Validity Range
Default Value
50 for ANSI and 60 for CCITT
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M2T7
mtl2Timer7
Excessive delay of acknowledgement timer
Validity Range
Default Value
10 for ANSI and 20 for CCITT
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T1
mtl3Timer1
Delay to avoid the out-of-sequence of messages on CO.
Validity Range
Default Value
9
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T10
mtl3Timer10
This attribute represents the waiting time to repeat the route set test message.
10 - 60 10-60 hundreds of ms for ANSI
30-60 hundreds of ms for CCITT
5 - 20 hundreds of milliseconds
5 - 12 hundreds of milliseconds


1848 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T12
mtl3Timer12
Wait for uninhibit acknowledgement.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T13
mtl3Timer13
Wait to force uninhibit.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T14
mtl3Timer14
Wait for inhibit acknowledgement.
60 - 120 (0,5 s step size)
60
8 - 15 (100 ms step size)
12
8 - 15 (100 ms step size)
8


A30808-X3247-M230-6-7619

1849
CML:BSC m
Id:0900d805800d8729
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T17
mtl3Timer17
Delay to avoid oscillation of the initial alignment.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T19
mtl3Timer19
Failed link craft referral timer. Default value 12 corresponds to 60 seconds.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T1TM
mtl3Timert1tm
Supervision timer for signalling link test acknowledgment message.
20 - 30 (100 ms step size)
20
8 - 15 (100 ms step size)
10
12 - 120 (5 s unit)
12


1850 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
Default Value
50 for ANSI and 100 for CCITT
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T2
mtl3Timer2
Wait for CO acknowledgement.
Validity Range
Default Value
13 for CCITT and 14 for ANSI.
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T22OR20
mtl3Timer22or20
Local inhibit test timer.
Validity Range
Default Value
22 for ANSI and 36 for CCITT
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T23OR21
mtl3Timer23or21
Remote inhibit test timer.
40 - 120 hundreds of milliseconds
7 - 20 hundreds of milliseconds
18 - 72 18-24 unit fo 5 s for ANSI
36-72 unit fo 5 s for CCITT


A30808-X3247-M230-6-7619

1851
CML:BSC m
Id:0900d805800d8729
Validity Range
Default Value
22 for ANSI and 36 for CCITT
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T2TM
mtl3Timert2tm
Interval timer for sending periodic link test message.
Validity Range
Default Value
6 for CCITT and 17 for ANSI
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T3
mtl3Timer3
Diversion delay controlled by a timer.
Validity Range
Default Value
9
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T4
mtl3Timer4
Wait for CB acknowledgement first attempt.
Validity Range
Default Value
8
18 - 72 18-24 unit fo 5 s for ANSI
36-72 unit fo 5 s for CCITT
6 - 18 unit of 5 seconds
5 - 12 hundreds of milliseconds
5 - 12 hundreds of milliseconds


1852 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
M3T5
mtl3Timer5
Wait for CB acknowledgement second attempt.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
MACONN
maxConnectionNumber
This attribute gives the maximum number of connections traced in this particular cell.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED
MADGRLV
maxDowngradeLevel
This attribute indicates the Maximum AIUR (Air Interface User Rate) Downgrade Level
for NT data calls from the initial request
(is meaningless if ENHSCSD = FALSE).
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
5 - 12 (100 ms step size)
8
1 - 128
0 - 3
2


A30808-X3247-M230-6-7619

1853
CML:BSC m
Id:0900d805800d8729
MAFAILNCU
maxFailNcUmtsCell
This parameter is the maximum number of packet cell change order messages trans-
mitted for the same UMTS Neighbour cell for a MS/UE, in case the ordered cell change
fails.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MAFIRACHO
maxForcedIntraCellHo
This attribute indicates the Maximum Number of Forced Intracell HO procedures to be
executed (is meaningless if ENHSCSD = FALSE or ENFOIAHO = FALSE).
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MAIO
maio
Offset of the Mobile Allocation Index used in the generation of the frequency hopping
sequence.
Validity Range
Default Value
In moc(s) CHAN:
None.
In moc(s) TRX:
0 - 100
4
1 - 3
2
0 - 63
<NULL>
NULL


1854 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Contained in the following commands:
CREATE CHAN, CREATE TRX, GET CHAN, GET TRX, SET CHAN, SET TRX
MAIRACHO
maxIntraCellHandover
This attribute specifies both the maximum number of consecutive successful Quality
IntraBSC Handovers and the maximum number of consecutive successful compres-
sion/decompression AMR Quality IntraBSC Handovers that are permitted in the same
BTS for a single connection: the IntraBSC cell Handover is suspended when the thresh-
old MAIRACHO + 1 is reached.
In case of normal call, the internal counter is increased for each successful Quality Han-
dover. In case of AMR call, the internal counter is increased for each couple of compres-
sion/decompression Handovers, i.e. FR -> HR and HR -> FR. If an AMR call is set up
on a HR channel the first decompression handover (HR -> FR) is not taken into account.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
MASCLOGFS
maxScannerLogFileSize
This attributes indicates the maximum size (in Mbytes) for each SCAN log file.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MAXFAILHO
maxFailHo
This attribute specifies the maximum number of consecutive failures of Intra and Inter
BSC Handovers permitted in the same BTS for a single connection.
1 - 15
2
1 - 12
3


A30808-X3247-M230-6-7619

1855
CML:BSC m
Id:0900d805800d8729
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
MAXLAPDMN
maxlapdmNumber
This attribute specifies the maximum number of lapdm.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MAXNCELL
maxNCell
It is the max number of adjacent cells on which the handover can be performed.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MAXRETR
maxNumberRetransmission
This parameter defines the maximum number of retransmissions a MS can perform on
the RACH.
1 - 15
2
5 - 12
5
1 - 16
6


1856 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
MEAEXTBCCH
measureExtraBCCH
This parameter enables/disables the feature "Automatic Procedure to measure extra
BCCH Frequencies per cell".
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
MEASET
measurementSets
This parameter represents the number of measurement sets to be provided by a call
drop record.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE HDCTR, GET HDCTR, SET HDCTR
MEASLST
measureList
One
Two
Four
Seven
Four
TRUE
FALSE
FALSE
1 - 16


A30808-X3247-M230-6-7619

1857
CML:BSC m
Id:0900d805800d8729
This parameter, used by all the scanner types, allows the user to define the list of the
measures to be executed by the scanner.
It consists of two fields.
The first field can be set to "measList" or to "allMeas" value. If "measList" value is
selected, the second field shows the measures list related to the type of the selected
scanner and the operator can select one or more measures.
If "allMeas" value is selected, the list of measures disappear (field equal to 0..0) and the
complete measure list is executed when the scanner will be activated.
Validity Range
In commands CREATE SCANBTSOHOI, GET SCANBTSOHOI, SET SCANBTSOHOI:
In commands CREATE SCANBTSE, GET SCANBTSE, SET SCANBTSE:
In commands CREATE SCANBSC, GET SCANBSC, SET SCANBSC:
measList SOUINIRH
AOUINIRH
UNINHOIE
allMeas 0 - 0
measList NINVRACH
NTDMPCH
AMRCHDIS
AMRVAR
AMRFRMUL
AMRFRMDL
AMRSIDUL
NINVPRACH
NTDMAGCH
NDEFCCCH
allMeas 0 - 0
measList SINHOBSC
TMSGREC
TMSHHDL
RFDBCUN
RFSUBUN
TCMSGREC
TCMSGSND
NMSUTRAS
NMSUREC
LOCAUTCH


1858 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
In commands CREATE SCANBTS, GET SCANBTS, SET SCANBTS:
DLKUNCON
NASPAVUN
DASPUNT
BSCPRCLD
HOFITABS
NRINHDFL
RQIISHDO
UNIISHDO
SUIISHDO
NPDCHPCU
allMeas 0 - 0
measList MEBUSTCH
AALTCHTI
NRFLTCH
NRFLSDCC
SINTHITA
TACCBPRO
NACSUCPR
NATTSDPE
ATSDCMBS
ATIMASCA
SUIMASCA
MEITCHIB
UNINHOIA
ATINHIAC
ATINHIRC
NAVSDCCH
NAVTCH
TNTCHCL
UNIHIALC
UNIHIRLC
ASDCALTI
MBUSYSDC
MAXBUSDC
TASSATT


A30808-X3247-M230-6-7619

1859
CML:BSC m
Id:0900d805800d8729
TASSSUCC
ATTCHSEI
SUCTCHSE
ATCHSMBS
MTCHBUTI
SINTHINT
TASSFAIL
NSUCCHPC
TNMSCNCL
MTCHQLEN
MDURTCRQ
NMSGDISQ
NASUSDPE
TNSUDHSC
TASSATVS
TASSUCVS
NNNOTNCH
NRDEFTCH
NDESDCCH
NHOINRHA
NAVTCHSD
NTCHSDCM
NDFTCHSD
AISHINTR
SISHINTR
UISHINTR
AISHINTE
SISHINTE
UISHINTE
AOINTESH
SOINTESH
UOINTESH
MBTCHCHT
MDURTCSD
NRCLRREQ
NRCLRCMD


1860 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
In commands CREATE SCANTRX, GET SCANTRX, SET SCANTRX:
In commands CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO:
In commands CREATE SCANGPRS, GET SCANGPRS, SET SCANGPRS:
aCADMCDMA
aCREJCDMA
UISHIALC
UISHIRLC
UMCSHLC
CHALNHLY
MEBUTSLY
WPSSUPV
MBUSYSSP
NSUSDSUS
allMeas 0 - 0
measList ILUPLKIC
TRANAVTI
allMeas 0 - 0
measList SININIRH
AININIRH
allMeas 0 - 0
measList NAVPDCH
REJPDASS
NUACATCL
SULACCEL
NRETPDU
NTDMPPCH
NSUGPPAG
MUTHRF
MSTHRF
MUTHBS
MSTHBS
NATPRRE
NSUPRRE
NACTTBF
TANRGPRS


A30808-X3247-M230-6-7619

1861
CML:BSC m
Id:0900d805800d8729
In commands CREATE SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM:
In commands CREATE SCANBTSOHOS, GET SCANBTSOHOS, SET SCANBTSO-
HOS:
REMUTHRF
NTRAPDU
LADAPTUD
SERVUGDG
NTRLLCFR
NDEFPDCH
NALIPDCH
NALLPDCH
NTBFPDC
MEANTBFL
NTDMPAGC
SUCPDASA
UNSPDCSE
SUCTETBF
NRRFPDU
UNSTETBF
DISCLPDU
ATCRORIG
SUCRORIG
UNCRORIG
LLCQULEV
NDEFPCCC
NSAPRACH
WUTHBS
MUTLLC
allMeas 0 - 0
measList ABISPDIS
ABISPSUP
allMeas 0 - 0
measList ATOISHDO
SUOISHDO
UNOISHDO
allMeas 0 - 0


1862 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
In commands CREATE SCANBTSOHON, GET SCANBTSOHON, SET SCANBTSO-
HON:
In commands CREATE SCANBTSM, GET SCANBTSM, SET SCANBTSM:
In commands GET SCANCHAN:
In commands GET SCANCTRX:
In commands CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L:
Default Value
None.
Contained in the following commands:
CREATE SCANBSC, CREATE SCANBTS, CREATE SCANBTSE, CREATE SCAN-
BTSIHO, CREATE SCANBTSM, CREATE SCANBTSOHOI, CREATE SCANBTSO-
HON, CREATE SCANBTSOHOS, CREATE SCANFBTSM, CREATE SCANGPRS,
CREATE SCANSS7L, CREATE SCANTRX, GET SCANBSC, GET SCANBTS, GET
SCANBTSE, GET SCANBTSIHO, GET SCANBTSM, GET SCANBTSOHOI, GET
SCANBTSOHON, GET SCANBTSOHOS, GET SCANCHAN, GET SCANCTRX, GET
SCANFBTSM, GET SCANGPRS, GET SCANSS7L, GET SCANTRX, SET
SCANBSC, SET SCANBTS, SET SCANBTSE, SET SCANBTSIHO, SET SCAN-
BTSM, SET SCANBTSOHOI, SET SCANBTSOHON, SET SCANBTSOHOS, SET
SCANFBTSM, SET SCANGPRS, SET SCANSS7L, SET SCANTRX
MEASOBJLST
measObjList
measList ATINBHDO
SUINBHDO
NRUNINHD
allMeas 0 - 0
measList BTSEPRLD
IFRMABIS
allMeas 0 - 0
PWRUPDW
CRXLEQTA
measList DLKSERST
DSLUNAV
SLFAILAL
allMeas 0 - 0
This parameter represents the list of the measures that have to be
executed.


A30808-X3247-M230-6-7619

1863
CML:BSC m
Id:0900d805800d8729
Validity Range
In commands ADD SCANSS7L, REMOVE SCANSS7L:
In commands ADD SCANBTSIHO, REMOVE SCANBTSIHO:
In commands ADD SCANBTSOHOI, REMOVE SCANBTSOHOI:
In commands ADD SCANCHAN, REMOVE SCANCHAN:
For the "list of all measures" related to the different type of scanners,
please refer to the chapter 4 of the manual "Performance Measure-
ment Counter".
measList DLKSERST
DSLUNAV
SLFAILAL
objList 1 to 16 items of
0 - 15
measlst SININIRH
AININIRH
objlst 1 to 10 items of
btsId btsmId 0 - 199
btaRelId 0 - 23
adjcList selfAdapt-
ing
0 - 0
origBts-
Group
1 to 32 items of
btsmId 0 - 199
btsId 0 - 23
measList SOUINIRH
AOUINIRH
UNINHOIE
adjcOhList 1 to 10 items of
btsId btsmId 0 - 199
btsId 0 - 23
adjcId selfAdapting 0 - 0
selectOb-
jects
1 to 32 items of
0 - 63
1 to 10 items of
btsmId 0 - 199


1864 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
In commands ADD SCANCTRX, REMOVE SCANCTRX:
In commands ADD SCANFBTSM, REMOVE SCANFBTSM:
In commands ADD SCANBTSE, REMOVE SCANBTSE:
btsId 0 - 23
trxId 0 - 23
chanId allTch 0 - 0
list Chan0
Chan1
Chan2
Chan3
Chan4
Chan5
Chan6
Chan7
1 to 25 items of
btsmId 0 - 199
btsId 0 - 23
trxId 0 - 23
measList ABISPDIS
ABISPSUP
ObjList 1 to 100 items of
0 - 199
measlst NINVRACH
NTDMPCH
AMRCHDIS
AMRVAR
AMRFRMUL
AMRFRMDL
AMRSIDUL
NINVPRACH
NTDMAGCH
NDEFCCCH
objlst 1 to 50 items of
btsmId 0 - 199
btsId 0 - 23


A30808-X3247-M230-6-7619

1865
CML:BSC m
Id:0900d805800d8729
In commands ADD SCANBTSM, REMOVE SCANBTSM:
In commands ADD SCANBTSOHOS, REMOVE SCANBTSOHOS:
In commands ADD SCANBTS, REMOVE SCANBTS:
measList BTSEPRLD
IFRMABIS
objList 1 to 100 items of
0 - 199
measList ATOISHDO
SUOISHDO
UNOISHDO
objList 1 to 10 items of
btsId btsmId 0 - 199
btsRelId 0 - 23
adjcList selfAdapting 0 - 0
selectOb-
jects
1 to 32 items of
0 - 63
measList MEBUSTCH
AALTCHTI
NRFLTCH
NRFLSDCC
SINTHITA
TACCBPRO
NACSUCPR
NATTSDPE
ATSDCMBS
ATIMASCA
SUIMASCA
MEITCHIB
UNINHOIA
ATINHIAC
ATINHIRC
NAVSDCCH
NAVTCH
TNTCHCL
UNIHIALC


1866 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
UNIHIRLC
ASDCALTI
MBUSYSDC
MAXBUSDC
TASSATT
TASSSUCC
ATTCHSEI
SUCTCHSE
ATCHSMBS
MTCHBUTI
SINTHINT
TASSFAIL
NSUCCHPC
TNMSCNCL
MTCHQLEN
MDURTCRQ
NMSGDISQ
NASUSDPE
TNSUDHSC
TASSATVS
TASSUCVS
NNNOTNCH
NRDEFTCH
NDESDCCH
NHOINRHA
NAVTCHSD
NTCHSDCM
NDFTCHSD
AISHINTR
SISHINTR
UISHINTR
AISHINTE
SISHINTE
UISHINTE
AOINTESH
SOINTESH


A30808-X3247-M230-6-7619

1867
CML:BSC m
Id:0900d805800d8729
In commands ADD SCANBTSOHON, REMOVE SCANBTSOHON:
In commands ADD SCANTRX, REMOVE SCANTRX:
UOINTESH
MBTCHCHT
MDURTCSD
NRCLRREQ
NRCLRCMD
ACADMCDMA
ACREJCDMA
UISHIALC
UISHIRLC
UMCSHLC
CHALNHLY
MEBUTSLY
WPSSUPV
MBUSYSSP
NSUSDSUS
objList 1 to 50 items of
BtsmIs 0 - 199
BtsId 0 - 23
measList ATINBHDO
SUINBHDO
NRUNINHD
adjcOhlist 1 to 10 items of
btsId btsmId 0 - 199
btsId 0 - 23
adjcId selfAdapting 0 - 0
selectOb-
jects
1 to 32 items of
0 - 63
measList ILUPLKIC
TRANAVTI
objList 1 to 25 items of
btsmId 0 - 199
btsId 0 - 23
trxId 0 - 23


1868 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
In commands ADD SCANBSC, REMOVE SCANBSC:
In commands ADD SCANGPRS, REMOVE SCANGPRS:
SINHOBSC
TMSGREC
TMSHHDL
RFDBCUN
RFSUBUN
TCMSGREC
TCMSGSND
NMSUTRAS
NMSUREC
LOCAUTCH
DLKUNCON
NASPAVUN
DASPUNT
BSCPRCLD
HOFITABS
NRINHDFL
RQIISHDO
UNIISHDO
SUIISHDO
NPDCHPCU
measList NAVPDCH
REJPDASS
NUACATCL
SULACCEL
NRETPDU
NTDMPPCH
NSUGPPAG
MUTHRF
MSTHRF
MUTHBS
MSTHBS
NATPRRE
NSUPRRE
NACTTBF


A30808-X3247-M230-6-7619

1869
CML:BSC m
Id:0900d805800d8729
Default Value
None.
Contained in the following commands:
ADD SCANBSC, ADD SCANBTS, ADD SCANBTSE, ADD SCANBTSIHO, ADD
SCANBTSM, ADD SCANBTSOHOI, ADD SCANBTSOHON, ADD SCANBTSOHOS,
ADD SCANCHAN, ADD SCANCTRX, ADD SCANFBTSM, ADD SCANGPRS, ADD
SCANSS7L, ADD SCANTRX, REMOVE SCANBSC, REMOVE SCANBTS, REMOVE
SCANBTSE, REMOVE SCANBTSIHO, REMOVE SCANBTSM, REMOVE SCANBT-
SOHOI, REMOVE SCANBTSOHON, REMOVE SCANBTSOHOS, REMOVE SCAN-
TANRGPRS
REMUTHRF
NTRAPDU
LADAPTUD
SERVUGDG
NTRLLCFR
NDEFPDCH
NALIPDCH
NALLPDCH
NTBFPDC
MEANTBFL
NTDMPAGC
SUCPDASA
UNSPDCSE
SUCTETBF
NRRFPDU
UNSTETBF
DISCLPDU
ATCRORIG
SUCRORIG
UNCRORIG
LLCQULEV
NDEFPCCC
NSAPRACH
WUTHBS
MUTLLC
objList 1 to 50 items of
BtsmId 0 - 199
BtsId 0 - 23


1870 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
CHAN, REMOVE SCANCTRX, REMOVE SCANFBTSM, REMOVE SCANGPRS,
REMOVE SCANSS7L, REMOVE SCANTRX
MECNT
measCount
This parameter specifies the minimum required measurement samples.
Validity Range
Default Value
Contained in the following commands:
CREATE RFLOOP, GET RFLOOP, SET RFLOOP
MEDAFUPE
measurementDataFileUploadPeri
The attribute defines the period between two upload of measurements data.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MEDAFUST
measurementDataFileUploadStart
100 - 1000
200
UPPE_0H periodic upload disabled
UPPE_15M periodic upload every 15 minutes
UPPE_30M periodic upload every 30 minutes
UPPE_1H periodic upload every 1 hour
UPPE_2H periodic uplaod every 2 hours
UPPE_3H periodic uplaod every 3 hours
UPPE_4H periodic uplaod every 4 hours
UPPE_6H periodic uplaod every 6 hours
UPPE_8H periodic uplaod every 8 hours
UPPE_12H periodic uplaod every 12 hours
UPPE_24H periodic uplaod every 24 hours
UPPE_0H


A30808-X3247-M230-6-7619

1871
CML:BSC m
Id:0900d805800d8729
The attribute defines the start time (hour:minute) for measurements data file freeze for
upload.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MELID
managedElementId
This parameter defines the name in the BSS.
Validity Range
Default Value
None.
Contained in the following commands:
GET MEL, SET MEL
MICROCELL
microcell
This parameter determines whether the adjacent cell is regarded as a 'microcell'. Only
if this parameter is set at TRUE the
'speed sensitive handover' algorithm will be in effect for this
neighbour cell. Precondition: the database flag for speed sensitive handover is set at
'enabled' (parameter DPBGTHO = TRUE in SET HAND command).
uploadStartHour 0 - 23
uploadStartMin 0 - 59
uploadStartHour 0
uploadStartMin 0
0 - 83


1872 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
MINCCNT
minCallCount
This attribute specifies the minimum required call count.
Validity Range
Default Value
Contained in the following commands:
CREATE RFLOOP, GET RFLOOP, SET RFLOOP
MISTSTRSH
missingTSThreshold
If the number of failed consecutive CHAN activations on one Abis timeslot (TSLB)
exceeds this threshold an alarm on all configured SUBTSLB objects (max 4) is emitted.
The alarm(s) indicate(s) that the timeslot is missing (e.g. not put into service by the
network provider). The configured threshold value is multiplied by 4, i.e. if the value is
set to 1 the threshold value is 4 and so on.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MNTBMASK
maintenanceBitMask
TRUE
FALSE
FALSE
20 - 250
50
1 - 40 (the value is internally multiplied by 4)
3


A30808-X3247-M230-6-7619

1873
CML:BSC m
Id:0900d805800d8729
The command allows to set 62 bits (bit0..bit61), however, only some of them can be
really modified by command. Several bits of the Maintenance bit mask are fixed to '0' or
'1' and cannot be changed.
Note: Bit 9 handles the PPXU Overload handling procedure.
0 = Disabled
1 = Enabled
Note: Bit 10 handles the Delayed TBF Release and Extended UL TBF during Mobility
Management (MM) procedures.
0 = Disabled
1 = Enabled
Note: Bit 12 handles the Resource Reallocation procedure.
0 = Disabled
1 = Enabled
Note: Bit 14 handles the one downlink time slot for both GPRS Mobility Management
and Signalling Management procedures.
0 = Disabled
1 = Enabled
Note: Bit 17 handles the forward of the "Remote Transcoder Failure" event report to the
Radio Commander without considering the settings of the ERRACT filter.
0 = Disabled
1 = Enabled
Note: Bit 22 set to 1 disables the usage of Variable Bitmap format in scenario where in
the same cell there is a mix of frequencies in ranges (0,1...124) and (975...1023).
Note: Bit 23 handles the Enabling PDT Release Improvements procedure.
0 = Disabled
1 = Enabled
Note: Bit 24 handles the setting of the 3G Early Classmark Sending Restrictor always to
H value in System Info and Packet System Info independently from Values of EUHO
(Enabling Umts Handover) object.
0 = Disabled
1 = Enabled


1874 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Note: Bit 25 handles the EDGE activation without CS3CS4 coding scheme procedure.
0 = Disabled
1 = Enabled
Note: Bit 26 handles the Power Budget HO procedure modification for DTM handling.
0 = Disabled
1 = Enabled
Note: Bit 27 set to 1 forces bitmap range 1024 format where in the same cell there is a
mix of frequencies in ranges (0...124) and (975...1023).
Note: The bits 30 and 31 are used to configure CCCH overload at following values:
Note: Bit 35 handles the sending of Network Control Order 2 messages to pre-Rel99
MSs:
0 = Disabled
1 = Enabled
Note: Bit 37 handles the setting of the PAGQOVLIND parameter to a value different from
0.
0 = Disabled
1 = Enabled
BIT 30 BIT 31 Result
0 0 Paging delivery rate at 130% of BTS total capacity
0 1 Paging delivery rate at 120% of BTS total capacity
1 0 Paging delivery rate at 110% of BTS total capacity
1 1 Paging delivery rate at 100% of BTS total capacity


A30808-X3247-M230-6-7619

1875
CML:BSC m
Id:0900d805800d8729
Validity Range
Bit0
Bit1
Bit2
Bit3
Bit4
Bit5
Bit6
Bit7
Bit8
Bit9
Bit10
Bit11
Bit12
Bit13
Bit14
Bit15
Bit16
Bit17
Bit18
Bit19
Bit20
Bit21
Bit22
Bit23
Bit24
Bit25
Bit26
Bit27
Bit28
Bit29
Bit30
Bit31
Bit32
Bit33
Bit34


1876 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Default Value
Contained in the following commands:
GET BSC, SET BSC
MOBALLOC
mobileAllocation
Bit35
Bit36
Bit37
Bit38
Bit39
Bit40
Bit41
Bit42
Bit43
Bit44
Bit45
Bit46
Bit47
Bit48
Bit49
Bit50
Bit51
Bit52
Bit53
Bit54
Bit55
Bit56
Bit57
Bit58
Bit59
Bit60
Bit61
Null
0000000000000000000000
0000000000000000000000
0000000000000000001


A30808-X3247-M230-6-7619

1877
CML:BSC m
Id:0900d805800d8729
A list of absolute frequencies used in hopping sequence: 64 frequencies at max (64 for
BBHOP and 63 for SYNHOP).


1878 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
1 to 64 items of
BCCHFREQ
CALLF01
CALLF02
CALLF03
CALLF04
CALLF05
CALLF06
CALLF07
CALLF08
CALLF09
CALLF10
CALLF11
CALLF12
CALLF13
CALLF14
CALLF15
CALLF16
CALLF17
CALLF18
CALLF19
CALLF20
CALLF21
CALLF22
CALLF23
CALLF24
CALLF25
CALLF26
CALLF27
CALLF28
CALLF29
CALLF30
CALLF31
CALLF32
CALLF33


A30808-X3247-M230-6-7619

1879
CML:BSC m
Id:0900d805800d8729
Default Value
None.
Contained in the following commands:
CREATE FHSY, GET FHSY, SET FHSY
CALLF34
CALLF35
CALLF36
CALLF37
CALLF38
CALLF39
CALLF40
CALLF41
CALLF42
CALLF43
CALLF44
CALLF45
CALLF46
CALLF47
CALLF48
CALLF49
CALLF50
CALLF51
CALLF52
CALLF53
CALLF54
CALLF55
CALLF56
CALLF57
CALLF58
CALLF59
CALLF60
CALLF61
CALLF62
CALLF63


1880 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
MODBSSPFCRET
modifyBSSPFCRetries
This attribute guards the MODIFY-BSS-PFC-RETRIES number.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
MODBSSPFCT
modifyBSSPFCTimer
This attribute represent the timer T8 and guards the MODIFY-BSSPFC procedure.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
MOEC
memberOfEmergencyConfig
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
1 - 5
3
2 - 99
50
The attribute specifies whether a TRX belongs to the emergency
configuration or not.
If this feature is used, the value TRUE should be used at least for the
BCCH-TRX.
TRUE
FALSE
TRUE


A30808-X3247-M230-6-7619

1881
CML:BSC m
Id:0900d805800d8729
MONOBJ
monitoredObject
This parameter defines the object on which it is possible to enter the GetCurrentValues
command.
Validity Range
Default Value
None.
Contained in the following commands:
GETCURRENTVALUES SCANBTS, GETCURRENTVALUES SCANBTSOHOI, GET-
CURRENTVALUES SCANBTSOHON, GETCURRENTVALUES SCANBTSOHOS,
GETCURRENTVALUES SCANFBTSM, GETCURRENTVALUES SCANGPRS, GET-
CURRENTVALUES SCANSS7L, GETCURRENTVALUES SCANTRX
MORT
MOT
This parameter defines the hardware unit to be diagnosed.
Validity Range
Default Value
None.
Pathname Scanner Object Class OBJ Format
SCANSS7L OBJ=SS7L:ss7ln
SCANBTS OBJ:BTSM:btsmn/BTS:btsn
SCANFBTSM OBJ:BTSM:btsmn
SCANTRX
OBJ:BTSM:btsmn/BTS:btsn/TRX:trxn
SCANGPRS OBJ:BTSM:btsmn/BTS:btsn/PTP-
PKF:ptppkfn
SCANBTSOHOI
OBJ:BTSM:btsmn/BTS:btsn/ADJC:adjcn
SCANBTSOHON
OBJ:BTSM:btsmn/BTS:btsn/ADJC:adjcn
SCANBTSOHOS
OBJ:BTSM:btsmn/BTS:btsn/ADJC3G:adjc3gn
Pathname (mnemonic of all the objects that can be tested).
The following objects can be tested:
DISK DK40 EPWR IXLT
LICD LICDS MEMT MPCC
NTW PPXU PWRD TDPC
PPXL CPEX ES


1882 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Contained in the following commands:
PERFTEST BSCE, STOPTEST BSCE
MPCCCOPY
mpccCopy
This parameter specifies from which MPCC board (MPCC:0 or MPCC:1) the ping
towards an external network element is executed.
Validity Range
Default Value
None.
Contained in the following commands:
PING IPLI
MSBHIPER
msBucketHighPercentage
If MS Bucket Level is greater than MSBHIPER * Bucket Size PCU then Bucket Conges-
tion is started.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MSBLPER
msBucketLowPercentage
If BVC Bucket Level is lower than MSBLPER * Bucket Size PCU then Bucket Conges-
tion is finished.
MPCC_0
MPCC_1
PER50
PER60
PER70
PER80
PER90
PER70


A30808-X3247-M230-6-7619

1883
CML:BSC m
Id:0900d805800d8729
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MSBMAPER
msBucketMaxPercentage
This attribute reduces the value of Bmax automatically computed by BSC. BSC criterion
is: (C + 1 sec.) * Rmax, where C is the timer reported in GSM 08.18 recommendation
and Rmax is the maximum rate assigned to BVC.
PER10
PER20
PER30
PER40
PER50
PER60
PER70
PER80
PER60


1884 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MSBSPPER
msBucketSizePcuPercentage
This attribute assigns the value of Bucket Size PCU as percentage of Bmax (twice and
so on).
PER010
PER020
PER030
PER040
PER050
PER060
PER070
PER080
PER090
PER100
PER110
PER120
PER130
PER140
PER150
PER160
PER170
PER180
PER190
PER200
PER100


A30808-X3247-M230-6-7619

1885
CML:BSC m
Id:0900d805800d8729
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MSCOVLH
mscOvlHand
This attribute allows a managing system to enable or disable the MSC Overload
Handling by BSC.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MSCPERTFLAG
mscPeriocTestFlag
This attribute represents the flag to enable the periodic test towards SMLC (SLT proce-
dure).
PER100
PER110
PER120
PER130
PER140
PER150
PER160
PER170
PER180
PER190
PER200
PER200
TRUE
FALSE
TRUE


1886 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
MSCPOOL
mscPooling
This attribute indicates whether the connected MSC is able to manage the pooling
feature or not.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MSCSPC
mscSignallingPointCode
This attribute identifies the destination system (MSC).
It consists of three fields: networkClusterMember, networkCluster and networkIdentifier;
the first two fields are mandatory while the third field is optional.
Validity Range
Default Value
None.
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
networkCluster-
Member
0 - 255 0-255 for CCITT
1-255 for ANSI
networkCluster 0 - 255 0-63 for CCITT
0-255 for ANSI
networkIdentifier 1 - 254 1-254 for ANSI
NO_CONFIG for CCITT


A30808-X3247-M230-6-7619

1887
CML:BSC m
Id:0900d805800d8729
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
MSCV
mscVersion
It is the identifier of the MSC version.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
MSRMAXU
mobileStationRateMaxUsed
If the value is TRUE, Rmax is used for Bmax and R computation, otherwise RGUA is
used.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MSTXPMAXCH
msTxPwrMaxCcch
PHASE1 it indicates a Phase 1 MSC
PHASE2 it indicates a Phase 2 MSC supporting neither Current
Channel nor Speech Version IES
PHASE2CC it indicates a Phase 2 MSC supporting the Current
Channel IE
PHASE2EFR it indicates a Phase 2 MSC supporting the Speech
Version used IE
PHASE2CCEFR it indicates a Phase 2 MSC supporting both Current
channel and Speech Version used IES
PHASE2CCEFR
TRUE
FALSE
FALSE


1888 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
This parameter is used in order to evaluate the path loss criterion parameter C1 or C2
of a cell. It indicates the maximum transmit power level a MS can use when getting
access to the system on a CCCH of the cell.
Validity Range
Default Value
5 if SYSID parameter value is BB900, EXT900 or GSMR
0 if SYSID parameter value is DCS1800 or PCS1900
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
MSTXPMAXDCS
msTxPwrMaxDcs
This parameter defines the maximum power level a MS can use in the serving cell for
DCS1800.
Validity Range
Default Value
0
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
MSTXPMAXGSM
msTxPwrMaxGsm
This parameter defines the maximum power level a MS can use in the serving cell for
the GSM 900, GSM850 and GSMR.
Validity Range
Default Value
5
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
0 - 31
0 - 15 For the values make references to Appendix B: Group 4.
<NULL>
2 - 15 For the values make references to Appendix B: Group 4.
<NULL>


A30808-X3247-M230-6-7619

1889
CML:BSC m
Id:0900d805800d8729
MSTXPMAXPCS
msTxPwrMaxPcs
This parameter defines the maximum power level a MS can use in the serving cell for
the PCS 1900.
Validity Range
Default Value
0
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
MSTXPMAXUMTS
msTxPwrMaxUmts
This parameter indicates the maximum transmission power level a UE is allowed to use
in the UMTS neighbouring cell.
Validity Range
Default Value
Contained in the following commands:
CREATE TGTFDD, CREATE TGTTDD, GET TGTFDD, GET TGTTDD, SET
TGTFDD, SET TGTTDD
MTU
mtu
This parameter indicates the maximum transmission unit, i.e. the size of the largest
packet that can be transmitted on the Ethernet.
Validity Range
Default Value
The default of MTU depends on the values of GBSNS attribute:
0 - 31 The selecting values are 0...15, 30 and 31.
For the values make references to Appendix B: Group 4.
<NULL>
0 - 19 For the values make references to Appendix B: Group 4
11
68 - 1500
<NULL>


1890 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d8729
m
GBSNS FRFIX IPV4
MTU NULL 1500
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU


A30808-X3247-M230-6-7619

1891
CML:BSC n
Id:0900d805800d1c8d
n
N1
n1
Maximum number of MSU available for retransmission.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
N2
n2
Maximum number of MSU octets available for retransmission.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
N2WC
numberOf2WayChannels
This parameter is included in the X25A and X25D configuration message (IXLT restart).
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
100 - 127
110
2000 - 4000
3000
0 - 4095
6


1892 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
N3101
n3101
This parameter implements the threshold for non valid data error coming by mobile
station after having sent USF. In case this threshold is reached, the communication with
the associated MS is broken.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
N3103
n3103
This parameter implements the threshold for not received Packet Control Ack as answer
of the Packet Uplink Ack/Nack. In case this threshold is reached, the communication
with the associated MS is broken.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
N3105
n3105
This parameter implements the threshold for not received RLC/MAC control message
from the MS after sending a RRBP field on downlink. If threshold is reached, the com-
munication with the associated MS is broken.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
9 - 255
10
1 - 255
10
1 - 255
20


A30808-X3247-M230-6-7619

1893
CML:BSC n
Id:0900d805800d1c8d
N391
n391
This parameter represents the polling cycle. It means that after N expirations of T391 a
Status Enquiry requiring a full status shall be sent to SGSN.
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
N392
n392
This attribute represents the error threshold on polling procedure (based on N391
counter) used to put the FRL in Disabled state.
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
N393
n393
This attribute represents the error observation window. If threshold N392 is reached on
N393 * T391 timer, the links are put in disabled state. If the threshold is not reached the
counters are restarted.
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
1 - 255
6
1 - 255
3
1 - 255
4


1894 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NACCNTWCOR
nACCNetworkControlOrder
This parameter defines the usage of Network Control Order during NACC when MS is
in Packet transfer Mode. When NACC is enabled, the value of this parameter is put in
the parameter Network Control Order inside Packet Measurement Order message.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NALLWACC
notAllowedAccessClasses
This attribute contains a list of MS Access Classes, which are not allowed to get access
to the cell. It should be noted that the access class number na10 does not exist as a
normal access class because it is used for emergency calls.
If ALLALLOWED is set then all the other fields are skipped (Both in SET and in GET
commands).
nc0 MS controlled cell reselection, no meas reportng;
nc1 MS controlled cell reselection, meas reporting;
nc0


A30808-X3247-M230-6-7619

1895
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NAVGI
nAverageInterference
This attribute represents an interfering signal strength filter constant for power control
2(k/2), k = 0, 1, ....; , 15.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
1 to 15 items of
na0
na1
na2
na3
na4
na5
na6
na7
na8
na9
na11
na12
na13
na14
na15
ALLALLOWED
1 ALLALLOWED
0 - 15
10


1896 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NBLKACGR
noOfBlocksForAccessGrant
This attribute specifies the number of CCCH blocks reserved for the Access Grant
channel within a period of 51 TDMA frames (a multiframe). A block consists of 4 con-
secutive TDMA frames.
Note: this attribute has to be always > 0 to support mobiles which don't handle
SI2quater.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NBVCBR
numberOfBvcBlockRetries
This parameter, used in BVCI block procedure, indicates the number of repetitions of
block procedure in case of not answering from SGSN, before sending an O&M alarm.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
NBVCRR
numberOfBvcResetRetries
This parameter, used in BVCI reset procedure, indicates the number of repetitions of
reset procedure in case of not answering from SGSN, before sending an O&M alarm.
0 - 7
1
1 - 30
3


A30808-X3247-M230-6-7619

1897
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
NBVCUR
numberOfBvcUnblockRetries
This parameter, used in BVCI unblock procedure, indicates the number of repetitions of
unblock procedure in case of not answering from SGSN, before sending an O&M alarm.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
NCC1TH
ncC1Threshold
1 - 30
3
1 - 30
3
This attribute establishes the threshold concerning the C1 value:
when a mobile has its C1 value under this threshold , it is moved to
an adjacent suitable cell.
The following list shows the correspondence between selected
values and real values:
DB00 0 dB
DB01 1 dB
....
....
....
DB63 63 dB


1898 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
DB00
DB01
DB02
DB03
DB04
DB05
DB06
DB07
DB08
DB09
DB10
DB11
DB12
DB13
DB14
DB15
DB16
DB17
DB18
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB26
DB27
DB28
DB29
DB30
DB31
DB32
DB33
DB34


A30808-X3247-M230-6-7619

1899
CML:BSC n
Id:0900d805800d1c8d
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
DB35
DB36
DB37
DB38
DB39
DB40
DB41
DB42
DB43
DB44
DB45
DB46
DB47
DB48
DB49
DB50
DB51
DB52
DB53
DB54
DB55
DB56
DB57
DB58
DB59
DB60
DB61
DB62
DB63
DB03


1900 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NCC1THADJC
ncC1ThresholdAdjacent
This attribute establishes the threshold concerning the C1 value for
an adjacent cell.
The following list shows the correspondence between selected
values and real values:
DB00 0 dB
DB01 1 dB
....
....
....
DB63 63 dB


A30808-X3247-M230-6-7619

1901
CML:BSC n
Id:0900d805800d1c8d
Validity Range
DB00
DB01
DB02
DB03
DB04
DB05
DB06
DB07
DB08
DB09
DB10
DB11
DB12
DB13
DB14
DB15
DB16
DB17
DB18
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB26
DB27
DB28
DB29
DB30
DB31
DB32
DB33
DB34


1902 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
NCDP1
noCallDetectionPeriod1
DB35
DB36
DB37
DB38
DB39
DB40
DB41
DB42
DB43
DB44
DB45
DB46
DB47
DB48
DB49
DB50
DB51
DB52
DB53
DB54
DB55
DB56
DB57
DB58
DB59
DB60
DB61
DB62
DB63
DB05


A30808-X3247-M230-6-7619

1903
CML:BSC n
Id:0900d805800d1c8d
The attribute allows to configure the first time-frame for the sleeping cell detection pro-
cedure. StartTime1 represents the beginning of the time-frame.TimerNoCall1 repre-
sents the observation period.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
startTime1 H0
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
H20
H21
H22
H23
timerNoCall1 1 - 432 (periods of 10 min.)
startTime1 H1
timerNoCall1 6


1904 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NCDP2
noCallDetectionPeriod2
The attribute allows to configure the second time-frame for the sleeping cell detection
procedure. StartTime2 represents the beginning of the time-frame. TimerNoCall2 repre-
sents the observation period.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
startTime2 H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
H20
H21
H22
H23
timerNoCall2 1 - 138 (periods of 10 min.)
<NULL>
startTime2 H6
timerNoCall2 1


A30808-X3247-M230-6-7619

1905
CML:BSC n
Id:0900d805800d1c8d
NCELL
nCell
This attribute defines the number of preferred cells for the evaluation of the target cell
list in the HO_COND_IND message.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
NCGPENTIME
ncGprsPenaltyTime
0 - 15
6
This attribute gives the duration for which the NcGprsTemporaryOff-
set is applied in GPRS Network Controlled Cell Reselection proce-
dure.
The following list shows the correspondence between selected
values and real values:
SEC000 0 seconds
SEC001 1 second
SEC002 2 seconds
SEC320 320 seconds


1906 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
SEC000
SEC001
SEC002
SEC003
SEC004
SEC005
SEC006
SEC007
SEC008
SEC009
SEC010
SEC011
SEC012
SEC013
SEC014
SEC015
SEC016
SEC017
SEC018
SEC019
SEC020
SEC021
SEC022
SEC023
SEC024
SEC025
SEC026
SEC027
SEC028
SEC029
SEC030
SEC031
SEC032
SEC033
SEC034


A30808-X3247-M230-6-7619

1907
CML:BSC n
Id:0900d805800d1c8d
SEC035
SEC036
SEC037
SEC038
SEC039
SEC040
SEC041
SEC042
SEC043
SEC044
SEC045
SEC046
SEC047
SEC048
SEC049
SEC050
SEC051
SEC052
SEC053
SEC054
SEC055
SEC056
SEC057
SEC058
SEC059
SEC060
SEC061
SEC062
SEC063
SEC064
SEC065
SEC066
SEC067
SEC068
SEC069
SEC070


1908 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
SEC071
SEC072
SEC073
SEC074
SEC075
SEC076
SEC077
SEC078
SEC079
SEC080
SEC081
SEC082
SEC083
SEC084
SEC085
SEC086
SEC087
SEC088
SEC089
SEC090
SEC091
SEC092
SEC093
SEC094
SEC095
SEC096
SEC097
SEC098
SEC099
SEC100
SEC101
SEC102
SEC103
SEC104
SEC105
SEC106


A30808-X3247-M230-6-7619

1909
CML:BSC n
Id:0900d805800d1c8d
SEC107
SEC108
SEC109
SEC110
SEC111
SEC112
SEC113
SEC114
SEC115
SEC116
SEC117
SEC118
SEC119
SEC120
SEC121
SEC122
SEC123
SEC124
SEC125
SEC126
SEC127
SEC128
SEC129
SEC130
SEC131
SEC132
SEC133
SEC134
SEC135
SEC136
SEC137
SEC138
SEC139
SEC140
SEC141
SEC142


1910 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
SEC143
SEC144
SEC145
SEC146
SEC147
SEC148
SEC149
SEC150
SEC151
SEC152
SEC153
SEC154
SEC155
SEC156
SEC157
SEC158
SEC159
SEC160
SEC161
SEC162
SEC163
SEC164
SEC165
SEC166
SEC167
SEC168
SEC169
SEC170
SEC171
SEC172
SEC173
SEC174
SEC175
SEC176
SEC177
SEC178


A30808-X3247-M230-6-7619

1911
CML:BSC n
Id:0900d805800d1c8d
SEC179
SEC180
SEC181
SEC182
SEC183
SEC184
SEC185
SEC186
SEC187
SEC188
SEC189
SEC190
SEC191
SEC192
SEC193
SEC194
SEC195
SEC196
SEC197
SEC198
SEC199
SEC200
SEC201
SEC202
SEC203
SEC204
SEC205
SEC206
SEC207
SEC208
SEC209
SEC210
SEC211
SEC212
SEC213
SEC214


1912 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
SEC215
SEC216
SEC217
SEC218
SEC219
SEC220
SEC221
SEC222
SEC223
SEC224
SEC225
SEC226
SEC227
SEC228
SEC229
SEC230
SEC231
SEC232
SEC233
SEC234
SEC235
SEC236
SEC237
SEC238
SEC239
SEC240
SEC241
SEC242
SEC243
SEC244
SEC245
SEC246
SEC247
SEC250
SEC260
SEC270


A30808-X3247-M230-6-7619

1913
CML:BSC n
Id:0900d805800d1c8d
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
NCGRESOFF
ncGprsReselectOffset
SEC280
SEC290
SEC300
SEC310
SEC320
SEC000
This attribute specifies to mobile station the positive or negative
offset and hysteresis to be applied to C32 value in the GPRS
Netwrok Controlled Cell Reselection procedure .
The set value ranges from -52 dB to +48 dB.
MDB52 -52 dB
MDB51 -51 dB
..... ......
MDB10 -10 dB
MDB9 -9 dB
..... ......
DB22 +22 dB
DB23 +23 dB
..... ......
DB48 +48 dB


1914 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
MDB52
MDB51
MDB50
MDB49
MDB48
MDB47
MDB46
MDB45
MDB44
MDB43
MDB42
MDB41
MDB40
MDB39
MDB38
MDB37
MDB36
MDB35
MDB34
MDB33
MDB32
MDB31
MDB30
MDB29
MDB28
MDB27
MDB26
MDB25
MDB24
MDB23
MDB22
MDB21
MDB20
MDB19
MDB18


A30808-X3247-M230-6-7619

1915
CML:BSC n
Id:0900d805800d1c8d
MDB17
MDB16
MDB15
MDB14
MDB13
MDB12
MDB11
MDB10
MDB09
MDB08
MDB07
MDB06
MDB05
MDB04
MDB03
MDB02
MDB01
DB00
DB01
DB02
DB03
DB04
DB05
DB06
DB07
DB08
DB09
DB10
DB11
DB12
DB13
DB14
DB15
DB16
DB17
DB18


1916 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB26
DB27
DB28
DB29
DB30
DB31
DB32
DB33
DB34
DB35
DB36
DB37
DB38
DB39
DB40
DB41
DB42
DB43
DB44
DB45
DB46
DB47
DB48
DB00


A30808-X3247-M230-6-7619

1917
CML:BSC n
Id:0900d805800d1c8d
NCGTEMPOFF
ncGprsTemporaryOffset
This attribute applies a negative offset to C32 for the duration of
NcGprsPenaltyTime in GPRS Network Controlled Cell Reselection
Procedure ..
The set value ranges from 0 dB to 60 dB.
The value NEVER means infinity.
DB00 0 dB
DB01 1 dB
..... ......
..... ......
DB59 +59 dB
DB60 +60 dB


1918 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
DB00
DB01
DB02
DB03
DB04
DB05
DB06
DB07
DB08
DB09
DB10
DB11
DB12
DB13
DB14
DB15
DB16
DB17
DB18
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB26
DB27
DB28
DB29
DB30
DB31
DB32
DB33
DB34


A30808-X3247-M230-6-7619

1919
CML:BSC n
Id:0900d805800d1c8d
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
DB35
DB36
DB37
DB38
DB39
DB40
DB41
DB42
DB43
DB44
DB45
DB46
DB47
DB48
DB49
DB50
DB51
DB52
DB53
DB54
DB55
DB56
DB57
DB58
DB59
DB60
NEVER
DB00


1920 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NCRARESH
ncRaReselectHysteresis
This attribute specifies the offset to apply to C32 of adjacent cell not
belonging to the same routing area of serving cell .It has to be set to
0 (its default value ), when the NcSameRoutingArea (NCSARA
parameter) is set to TRUE
The following list shows the correspondence between selected
values and real values:
DB00 0 dB
DB01 1 dB
....
....
....
DB30 30 dB


A30808-X3247-M230-6-7619

1921
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
DB00
DB01
DB02
DB03
DB04
DB05
DB06
DB07
DB08
DB09
DB10
DB11
DB12
DB13
DB14
DB15
DB16
DB17
DB18
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB26
DB27
DB28
DB29
DB30
DB00


1922 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NCRESELFLAG
ncReselectionFlag
This parameter enable/disable the network cell reselection feature
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NCSARA
ncSameRoutingArea
When this attribute is set to TRUE , the adjacent cell is searched before among the
cells belonging to same routing area of serving cell. When this attribute is set to FALSE
, the adjacent cells of the same routing area have not priority compared to the adjacent
cells of other routing areas When this attribute is set to TRUE , the attribute sbsN-
cRaReselectHysteresis has to be set to 0 (DB00) , which is its default value
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
NCTRFPSCTH
ncTrafficPSControlThreshold
This attribute indicates the threshold under which no other gprs mobiles are ordered to
change cell.
DISABLE
ENABLE
DISABLE
TRUE
FALSE
TRUE


A30808-X3247-M230-6-7619

1923
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
NE
networkEntity
This attribute defines the type and the instance number of the Network Element, con-
nected to the BSC, that must be aligned.
BTSEC is not supported.
Validity Range
Default Value
None.
Contained in the following commands:
ALIGN REMINV
NECI
newEstablishCauseIndication
The parameter defines if new establishment causes are supported by the network.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NETWTYPE
networkType
30 - 100 (step 1)
75
Ne BTSE
TRAUE
BTSEC
Addr1 0 - 363
TRUE
FALSE
FALSE


1924 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
This parameter indicates the type of network.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NEWESU
newESU
This read-only parameter defines indicates which software will be used in the next
change version operation.
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCOSUDB, GET BSCOSUSW
NFRAMEPG
noOfMultiFramesBetweenPaging
This value specifies the number of multiframes (51 frames) between two transmissions
of the same paging message to mobiles of the same paging group.
GSMDCS
GSMPCS
GSMR
GSM850PCS
GSM850DCS
GSMRAILPUB
GSMDCSTSM
GSMPCSTSM
GSMDCS
<ANY> pathname
<NULL>


A30808-X3247-M230-6-7619

1925
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NIOC
numberOfIncomingOnly
This read-only parameter defines the number of incoming only
channels, included in the X25A and X25D configuration message (IXLT restart).
Validity Range
Default Value
3
Contained in the following commands:
GET X25A, GET X25D
NMDLATT<NN>
normalMeasAttr<nn>
Sixty-four parameters are provided (<nn> from 1 to 64).
This parameter defines a pair of "BCCH frequencies-BSIC" for Normal Measures obser-
vation.
Each parameter consists of three fields: bcchFrequency,
netColorCode and bsColorCode.
The <NULL> value can be set for each NMDLATT<nn> parameter.
Validity Range
Default Value
Contained in the following commands:
CREATE SCA, GET SCA, SET SCA
2 - 9
2
0 - 4095
bcchFrequency 0 - 1023
netColorCode 0 - 7
bsColorCode 0 - 7
<NULL>
NULL


1926 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NMO
networkModeOfOperation
Network mode of operation (I, II and III).
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
NMULBAC
nMultibandcell
This attribute specifies the minimum number of neighbour cells reported by MS not
belonging the frequency band of the serving cell (see Recc. GSM 5.08 v4.18.1 par. 8.4
for more detailed description).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NNSVCBLKR
numberOfNsvcBlockRetries
This parameter specifies the maximum number of retries performed in the NSVC block
procedure. If the SGSN does not answer to block procedure, the procedure shall be
retried for NNSVCBLKR times.
Validity Range
Default Value
The default of NNSVCBLKR depends on the value of GBSNS attribute:
NMO_1
NMO_2
NMO_3
NMO_2
0 - 3
0
1 - 254
<NULL>


A30808-X3247-M230-6-7619

1927
CML:BSC n
Id:0900d805800d1c8d
GBSNS FRFIX IPV4
NNSVCBLKR 3 NULL
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
NNSVCRR
numberOfNsvcResetRetries
This parameter specifies the maximum number of retries performed in the NSVC reset
procedure before generating any alarm. If the SGSN does not answer to reset proce-
dure, the procedure shall be retried infinitely but after NNSVCRR times an O&M alarm
shall be notified.
Validity Range
Default Value
The dedault of NNSVCRR depends on the value of GBSNS attribute:
GBSNS FRFIX IPV4
NNSVCRR 10 NULL
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
NNSVCTSTR
numberOfNsvcTestRetries
This parameter defines the number of consecutive retries performed for test procedure
before declaring link not available.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
NNSVCUBLR
numberOfNsvcUnblockRetries
This parameter specifies the maximum number of retries performed in the NSVC block
procedure. If the SGSN does not answer to unblock procedure, the procedure shall be
retried for NNSVCUBLR times.
1 - 254
<NULL>
1 - 30
10


1928 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
Default Value
The dedault of NNSVCUBLR depends on the value of GBSNS attribute:
GBSNS: FRFIX IPV4
NNSVCUBLR: 3 NULL
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
NOBAKHO
enableNobackHo
This attribute is used to enable/disable the 'Prevention of Back Handover' feature.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
NOCHBLKN
notificationChannelBlockNumber
This parameter indicates the number of CCCH blocks to be used for the NCH channel
(a block consists of 4 consecutive TDMA frames).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NOCHFBLK
notificationChannelFirstBlock
1 - 254
<NULL>
TRUE
FALSE
TRUE
1 - 4
1


A30808-X3247-M230-6-7619

1929
CML:BSC n
Id:0900d805800d1c8d
This parameter indicates the first CCCH block to be used for the NCH channel (a block
consists of 4 consecutive TDMA frames).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NOFREPHO
enableNoFailRepHo
This attribute is used to enable/disable the 'Prevention of Handover failures repetition'
feature.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
NOIREDA
noiseReductionAmount
This attribute indicates the total amount of desired noise reduction (dB).
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
NOIREDST
noiseReductionStatus
This attribute enables/disables the Noise Reduction (NR) feature.
1 - 7
1
TRUE
FALSE
TRUE
-18 - -6
-12


1930 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
NOOC
numberOfOutgoingOnly
This read-only parameter defines the number of outgoing only channels, included in the
X25A and X25D configuration message (IXLT restart).
Validity Range
Default Value
0
Contained in the following commands:
GET X25A, GET X25D
NOTFACCH
notificationOnFACCH
This parameter indicates the Notification/FACCH message that will be sent for some
kind of calls.
disabled
enabled
disabled
0 - 4095


A30808-X3247-M230-6-7619

1931
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NRACPBLUPDRET
numberRaCapabilityUpdateRetries
This attribute provides the maximum number of retransmission of RA-Capability-Update
to SGSN when BSC does not accept correspondent answer (RA-Capability-Update-
Ack) from SGSN.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
NRLCMAX
numberRlcMax
When N_RLC_MAX Uplink RLC Blocks are received, one PACKET UPLINK
ACK/NACK is sent in acknowledged mode.
ALWAYS (Notification/FACCH will always be sent)
HIGHEQ4 (Notification/FACCH will always be sent for calls having
priority equal or higher than 4)
HIGHEQ3 (Notification/FACCH will always be sent for calls having
priority equal or higher than 3)
HIGHEQ2 (Notification/FACCH will always be sent for calls having
priority equal or higher than 2)
HIGHEQ1 (Notification/FACCH will always be sent for calls having
priority equal or higher than 1)
HIGHEQ0 (Notification/FACCH will always be sent for calls having
priority equal or higher than 0)
HIGHEQB (Notification/FACCH will always be sent for calls having
priority equal or higher than B)
EQA (Notification/FACCH will always be sent for calls having
priority equal to A)
NOSUPP (Notification/FACCH not supported)
HIGHEQB
1 - 30
3


1932 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
NRPGRANT
numberRepetitionGrant
The numberRepetitionGrant used maximum number of the repetition of the
VGCS_UPLINK_GRANT message during an uplink access procedure..
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NSCONN
ntwServiceConnection
This parameter is used to specify the allowed connections to local IP endpoints.
20 - 64
20
1 - 254
20


A30808-X3247-M230-6-7619

1933
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RNSVLIP, GET RNSVLIP, SET RNSVLIP
NSEI
networkServiceElementIdentifier
This parameter represents the PCU area identification. This attribute can be set only if
the object PCU is in locked state.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
all 0 - 0
ntwServiceConnec-
tion
NSCON0
NSCON1
NSCON2
NSCON3
NSCON4
NSCON5
NSCON6
NSCON7
NSCON8
NSCON9
NSCON10
NSCON11
NSCON12
NSCON13
NSCON14
NSCON15
0 - 65534


1934 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NSLOTST
numberOfSlotSpreadTrans
This attribute is used to represent the maximum number of RACH slots an MS must wait,
after an unsuccessful random access attempt, before a new random access. The MS
draws a random number between 0 and the value of this parameter allows the access
retransmission to be spread over a fixed number of RACH slots.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
NSVCI
nsvcIdentifier
This parameter represents the common identification of the virtual connection between
SGSN and BSS.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE NSVC, GET NSVC
NSVLI
nsvlIdentifier
The NSVCI (Network Service Virtual Link Identifier) parameter defines the association
of the FR-DLCI (Data Link Connection
Identifier) and the FRL (Frame Relay Link).
It consists of two mandatory fields: FRLN and DLCIN.
Validity Range
Default Value
None.
0 - 15
10
0 - 65535
Frln 0 - 755
Dlcin 16 - 991


A30808-X3247-M230-6-7619

1935
CML:BSC n
Id:0900d805800d1c8d
Contained in the following commands:
CREATE NSVC, GET NSVC
NTWCARD
networkCard
This attribute indicates the network card in use.
Validity Range
Default Value
NTWSNAP
Contained in the following commands:
GET BSC, SET BSC
NTWCNDRXP
networkControlNonDRXPeriod
This parameter indicates the minimum time the mobile station shall stay in non-DRX
mode after an NCmeasurement report has been sent.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
NTWCONCRESFAIR
networkControlledCellReselFailureRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
NTWSNAP
NTWSNAP_STLP
NODRX
MSEC0240
MSEC0480
MSEC0720
MSEC0960
MSEC1200
MSEC1440
MSEC1920
MSEC0480


1936 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONGPRS, GET QSMONGPRS, SET QSMONGPRS
NTWCOR
networkControlOrder
This parameter, reported in SI 13, PSI 1 and PSI 5, informs the mobile about the control
of cell reselection.
Validity Range
Default Value
nc0
Contained in the following commands:
GET PTPPKF
NTWCREPPIDL
networkControlReportPeriodIdle
This field indicates the time period for cell reselection measurement reporting when ms
is in packet idle mode
Pathname
<NULL>
NULL
nc0 MS controlled cell reselection, no meas reportng;
nc1 MS controlled cell reselection, meas reporting;


A30808-X3247-M230-6-7619

1937
CML:BSC n
Id:0900d805800d1c8d
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
NTWCREPPTR
networkControlReportPeriodTransfer
This parameter is used to define the delay between the reception by the mobile station
of the PMO message and the sending of the related PMR mesage with the required
measurements.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
NTWEL
networkElement
MSEC00480
MSEC00960
MSEC01920
MSEC03840
MSEC07680
MSEC15360
MSEC30720
MSEC61440
MSEC61440
MSEC00480
MSEC00960
MSEC01920
MSEC03840
MSEC07680
MSEC15360
MSEC30720
MSEC61440
MSEC03840


1938 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
This attribute specifies the Network Element (BTSE or TRAUE), a user friendly name (is
a user-defined string) to the BSC Executable Software Unit DB (note it is the same of
the related BSC Reusable Software Unit DB).
For BTSE only also the mode attribute is required and it can assume the FORCED and
UNFORCED values. If the FORCED value is set, the files already present on the NEY
flash EPROM are overwritten otherwise they are not.
The BTSEC is not supported.
Validity Range
In commands NEDOWNLOAD NEYESUSW:
btse neListBtse NE_NUMBER_
000
NE_NUMBER_
001
NE_NUMBER_
002
NE_NUMBER_
003
NE_NUMBER_
004
NE_NUMBER_
005
NE_NUMBER_
006
NE_NUMBER_
007
NE_NUMBER_
008
NE_NUMBER_
009
NE_NUMBER_
010
NE_NUMBER_
011
NE_NUMBER_
012
NE_NUMBER_
013
NE_NUMBER_
014
NE_NUMBER_
015


A30808-X3247-M230-6-7619

1939
CML:BSC n
Id:0900d805800d1c8d
NE_NUMBER_
016
NE_NUMBER_
017
NE_NUMBER_
018
NE_NUMBER_
019
NE_NUMBER_
020
NE_NUMBER_
021
NE_NUMBER_
022
NE_NUMBER_
023
NE_NUMBER_
024
NE_NUMBER_
025
NE_NUMBER_
026
NE_NUMBER_
027
NE_NUMBER_
028
NE_NUMBER_
029
NE_NUMBER_
030
NE_NUMBER_
031
NE_NUMBER_
032
NE_NUMBER_
033
NE_NUMBER_
034
NE_NUMBER_
035
NE_NUMBER_
036


1940 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NE_NUMBER_
037
NE_NUMBER_
038
NE_NUMBER_
039
NE_NUMBER_
040
NE_NUMBER_
041
NE_NUMBER_
042
NE_NUMBER_
043
NE_NUMBER_
044
NE_NUMBER_
045
NE_NUMBER_
046
NE_NUMBER_
047
NE_NUMBER_
048
NE_NUMBER_
049
NE_NUMBER_
050
NE_NUMBER_
051
NE_NUMBER_
052
NE_NUMBER_
053
NE_NUMBER_
054
NE_NUMBER_
055
NE_NUMBER_
056
NE_NUMBER_
057


A30808-X3247-M230-6-7619

1941
CML:BSC n
Id:0900d805800d1c8d
NE_NUMBER_
058
NE_NUMBER_
059
NE_NUMBER_
060
NE_NUMBER_
061
NE_NUMBER_
062
NE_NUMBER_
063
NE_NUMBER_
064
NE_NUMBER_
065
NE_NUMBER_
066
NE_NUMBER_
067
NE_NUMBER_
068
NE_NUMBER_
069
NE_NUMBER_
070
NE_NUMBER_
071
NE_NUMBER_
072
NE_NUMBER_
073
NE_NUMBER_
074
NE_NUMBER_
075
NE_NUMBER_
076
NE_NUMBER_
077
NE_NUMBER_
078


1942 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NE_NUMBER_
079
NE_NUMBER_
080
NE_NUMBER_
081
NE_NUMBER_
082
NE_NUMBER_
083
NE_NUMBER_
084
NE_NUMBER_
085
NE_NUMBER_
086
NE_NUMBER_
087
NE_NUMBER_
088
NE_NUMBER_
089
NE_NUMBER_
090
NE_NUMBER_
091
NE_NUMBER_
092
NE_NUMBER_
093
NE_NUMBER_
094
NE_NUMBER_
095
NE_NUMBER_
096
NE_NUMBER_
097
NE_NUMBER_
098
NE_NUMBER_
099


A30808-X3247-M230-6-7619

1943
CML:BSC n
Id:0900d805800d1c8d
NE_NUMBER_
100
NE_NUMBER_
101
NE_NUMBER_
102
NE_NUMBER_
103
NE_NUMBER_
104
NE_NUMBER_
105
NE_NUMBER_
106
NE_NUMBER_
107
NE_NUMBER_
108
NE_NUMBER_
109
NE_NUMBER_
110
NE_NUMBER_
111
NE_NUMBER_
112
NE_NUMBER_
113
NE_NUMBER_
114
NE_NUMBER_
115
NE_NUMBER_
116
NE_NUMBER_
117
NE_NUMBER_
118
NE_NUMBER_
119
NE_NUMBER_
120


1944 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NE_NUMBER_
121
NE_NUMBER_
122
NE_NUMBER_
123
NE_NUMBER_
124
NE_NUMBER_
125
NE_NUMBER_
126
NE_NUMBER_
127
NE_NUMBER_
128
NE_NUMBER_
129
NE_NUMBER_
130
NE_NUMBER_
131
NE_NUMBER_
132
NE_NUMBER_
133
NE_NUMBER_
134
NE_NUMBER_
135
NE_NUMBER_
136
NE_NUMBER_
137
NE_NUMBER_
138
NE_NUMBER_
139
NE_NUMBER_
140
NE_NUMBER_
141


A30808-X3247-M230-6-7619

1945
CML:BSC n
Id:0900d805800d1c8d
NE_NUMBER_
142
NE_NUMBER_
143
NE_NUMBER_
144
NE_NUMBER_
145
NE_NUMBER_
146
NE_NUMBER_
147
NE_NUMBER_
148
NE_NUMBER_
149
NE_NUMBER_
150
NE_NUMBER_
151
NE_NUMBER_
152
NE_NUMBER_
153
NE_NUMBER_
154
NE_NUMBER_
155
NE_NUMBER_
156
NE_NUMBER_
157
NE_NUMBER_
158
NE_NUMBER_
159
NE_NUMBER_
160
NE_NUMBER_
161
NE_NUMBER_
162


1946 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NE_NUMBER_
163
NE_NUMBER_
164
NE_NUMBER_
165
NE_NUMBER_
166
NE_NUMBER_
167
NE_NUMBER_
168
NE_NUMBER_
169
NE_NUMBER_
170
NE_NUMBER_
171
NE_NUMBER_
172
NE_NUMBER_
173
NE_NUMBER_
174
NE_NUMBER_
175
NE_NUMBER_
176
NE_NUMBER_
177
NE_NUMBER_
178
NE_NUMBER_
179
NE_NUMBER_
180
NE_NUMBER_
181
NE_NUMBER_
182
NE_NUMBER_
183


A30808-X3247-M230-6-7619

1947
CML:BSC n
Id:0900d805800d1c8d
NE_NUMBER_
184
NE_NUMBER_
185
NE_NUMBER_
186
NE_NUMBER_
187
NE_NUMBER_
188
NE_NUMBER_
189
NE_NUMBER_
190
NE_NUMBER_
191
NE_NUMBER_
192
NE_NUMBER_
193
NE_NUMBER_
194
NE_NUMBER_
195
NE_NUMBER_
196
NE_NUMBER_
197
NE_NUMBER_
198
NE_NUMBER_
199
userLabel 1..30 characters
string
mode FORCED
UNFORCED
traue neListTraue NE_NUMBER_
000
NE_NUMBER_
001
NE_NUMBER_
002


1948 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
NE_NUMBER_
003
NE_NUMBER_
004
NE_NUMBER_
005
NE_NUMBER_
006
NE_NUMBER_
007
NE_NUMBER_
008
NE_NUMBER_
009
NE_NUMBER_
010
NE_NUMBER_
011
NE_NUMBER_
012
NE_NUMBER_
013
NE_NUMBER_
014
NE_NUMBER_
015
NE_NUMBER_
016
NE_NUMBER_
017
NE_NUMBER_
018
NE_NUMBER_
019
NE_NUMBER_
020
NE_NUMBER_
021
NE_NUMBER_
022
NE_NUMBER_
023


A30808-X3247-M230-6-7619

1949
CML:BSC n
Id:0900d805800d1c8d
NE_NUMBER_
024
NE_NUMBER_
025
NE_NUMBER_
026
NE_NUMBER_
027
NE_NUMBER_
028
NE_NUMBER_
029
NE_NUMBER_
030
NE_NUMBER_
031
NE_NUMBER_
032
NE_NUMBER_
033
NE_NUMBER_
034
NE_NUMBER_
035
NE_NUMBER_
036
NE_NUMBER_
037
NE_NUMBER_
038
NE_NUMBER_
039
NE_NUMBER_
040
NE_NUMBER_
041
NE_NUMBER_
042
NE_NUMBER_
043
NE_NUMBER_
044


1950 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1c8d
n
In commands GET NEYESUSW:
In commands GET RSUSWLH:
Default Value
None.
Contained in the following commands:
GET NEYESUSW, GET RSUSWLH, NEDOWNLOAD NEYESUSW
NTWIND
networkIndicator
(Network Indicator) Signalling Network Indicator where the BSS is connected. The only
value allowed for ANSI is NAT0.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC
NE_NUMBER_
045
NE_NUMBER_
046
NE_NUMBER_
047
userLabel 1..30 characters
string
BTSE
TRAUE
BTSEC
BSC
BTSE
TRAUE
BTSEC
INAT0
INAT1
NAT0
NAT1
NAT0


A30808-X3247-M230-6-7619

1951
CML:BSC n
Id:0900d805800d1c8d
NUA
nua
Validity Range
Default Value
FALSE
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
NY1
ny1
This attribute indicates the maximum number of repetitions of PHYSICAL INFORMA-
TION messages from the network to the MS during an asynchronous handover.
The NY1 should be increased to avoid unnecessary call drop counts for CONNECTION
FAILURE cause "handover access failure" in accordance with the handling of the timer
T3105. Please refer to the description of parameter T3105 (see command SET BTS) for
further details.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
Not Urgent Alarm: it is used to enable or disable the handling of Not
Urgent Alarm on the 2 Mbit/s port.
This attribute is significative only for PCM30 lines
TRUE
FALSE
<NULL>
1 - 254
30


1952 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecd5
o
o
OBJLST
objectList
This parameter provides choices for the definition of monitored object; it is mandatory
for the CREATE commands.
Validity Range
In commands CREATE SCANBTSOHOS, GET SCANBTSOHOS, SET SCANBTSO-
HOS:
In commands CREATE SCANBTSIHO, GET SCANBTSIHO, SET SCANBTSIHO:
In commands CREATE SCANBTS, CREATE SCANGPRS, GET SCANBTS, GET
SCANGPRS, SET SCANBTS, SET SCANGPRS:
In commands CREATE SCANBTSOHOI, CREATE SCANBTSOHON, GET SCANBT-
SOHOI, GET SCANBTSOHON, SET SCANBTSOHOI, SET SCANBTSOHON:
1 to 10 items of
btsId btsmId 0 - 199
btsId 0 - 23
adjc3gList selfAdapting 0 - 0
selectObjects 1 to 32 items of
0 - 63
1 to 10 items of
btsId btsmId 0 - 199
btsId 0 - 23
btsAdjcList selfAdapting 0 - 0
origBtsGroup 1 to 32 items of
btsmId 0 - 199
btsId 0 - 23
selectObjects 1 to 50 items of
btsmId 0 - 199
btsId 0 - 23
selfAdapting 0 - 0
1 to 10 items of
btsId btsmId 0 - 199
btsId 0 - 23
adjcId selfAdapting 0 - 0
selectObjects 1 to 32 items of


A30808-X3247-M230-6-7619

1953
CML:BSC o
Id:0900d805800cecd5
In commands CREATE SCANBTSM, GET SCANBTSM, SET SCANBTSM, CREATE
SCANFBTSM, GET SCANFBTSM, SET SCANFBTSM:
In commands CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX:
In commands CREATE SCANTRX, GET SCANTRX, SET SCANTRX:
In commands CREATE SCANBTSE, GET SCANBTSE, SET SCANBTSE:
In commands CREATE SCANCHAN, GET SCANCHAN, SET SCANCHAN:
0 - 63
selectObjects 1 to 100 items of
0 - 199
selfAdapting 0 - 0
selfAdapting 0 - 0
trxList 1 to 25 items of
btsmId 0 - 199
btsId 0 - 23
trxId 0 - 23
selectObjects 1 to 25 items of
btsmId 0 - 199
btsId 0 - 23
trxId 0 - 23
selfAdapting 0 - 0
selfAdapting 0 - 0
btsList 1 to 50 items of
btsmId 0 - 199
btsId 0 - 23
1 to 10 items of
btsmId 0 - 199
btsId 0 - 23
trxId 0 - 23
chanId allTch 0 - 0
list chan0
chan1
chan2
chan3
chan4
chan5


1954 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecd5
o
In commands CREATE SCANSS7L, GET SCANSS7L, SET SCANSS7L:
Default Value
None.
Contained in the following commands:
CREATE SCANBTS, CREATE SCANBTSE, CREATE SCANBTSIHO, CREATE
SCANBTSM, CREATE SCANBTSOHOI, CREATE SCANBTSOHON, CREATE
SCANBTSOHOS, CREATE SCANCHAN, CREATE SCANCTRX, CREATE SCANF-
BTSM, CREATE SCANGPRS, CREATE SCANSS7L, CREATE SCANTRX, GET
SCANBTS, GET SCANBTSE, GET SCANBTSIHO, GET SCANBTSM, GET SCAN-
BTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS, GET SCANCHAN, GET
SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET SCANSS7L, GET
SCANTRX, SET SCANBTS, SET SCANBTSE, SET SCANBTSIHO, SET SCAN-
BTSM, SET SCANBTSOHOI, SET SCANBTSOHON, SET SCANBTSOHOS, SET
SCANCHAN, SET SCANCTRX, SET SCANFBTSM, SET SCANGPRS, SET
SCANSS7L, SET SCANTRX
OMCCPT
omcCapabilityTimer
This parameter represents the time period of the reachability test performed by RC on
the "cold standby" OMAL.
Validity Range
Default Value
60
Contained in the following commands:
CREATE OMAL, GET OMAL, SET OMAL
OMLAPDRT
omLapdRelTimer
At the detection time of the Abis link failure the BTSE starts the timer OMLAPDRT and
the BSC starts the timer SHLAPDIT. If the timer OMLAPDRT expires, the BTSE blocks
the cell processing. After that the BTSE forces the BSC (via a RestartSendingEventRe-
ports - NACK message) to perform a complete Abis alignment. If none of the two timers
expire, the BSC performs a "Short Abis alignment".
chan6
chan7
selectObjects 1 to 16 items of
0 - 15
selfAdapting 0 - 0
1 - 60 (1 minute step size)
<NULL>


A30808-X3247-M230-6-7619

1955
CML:BSC o
Id:0900d805800cecd5
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
OPC
originatingPointCode
This attribute identifies the originating system (BSS). It consists of three fields: Network-
ClusterMember, NetworkCluster,
NetworkIdentifier.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE OPC, GET OPC
OUTPUT
output
This attribute identifies the file name where to store ECHO outputs.
Validity Range
Default Value
None.
Contained in the following commands:
SET LMT-INTERNAL
OVERWRITE
Overwrite
This parameter specifies if the file has to be overwritten or not.
3 - 300 (1 second step size)
30
networkCluster-
Member
0 - 255
networkCluster 0 - 255
networkIdentifier 1 - 254
0..80 characters string


1956 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecd5
o
Validity Range
Default Value
None.
Contained in the following commands:
DNLFILE SOFTWARE-MANAGEMENT, UPLALLCELLTR CTRCO, UPLALLIMSITR
TRACE, UPLBTSLOG SOFTWARE-MANAGEMENT, UPLBTSTDLOG SOFTWARE-
MANAGEMENT, UPLCELLTR CTRCO, UPLCIDF REMINV, UPLFILE SOFTWARE-
MANAGEMENT, UPLIMSITR TRACE, UPLLIDF REMINV, UPLMEAS SCANCO,
UPLOADREQ RFLOOP, UPLOADREQ SCA, UPLPRLOG FILEHANDLER, UPL-
TRAULOG SOFTWARE-MANAGEMENT
OVLENTHR
ovlEndThreshold
End threshold for Overload Handling within BSC. The value refer to TDPC processor
load, expressed as 100 * <TDPC processor real-time> (e.g. 8000 means TDPC real-
time = 80%).
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
OVLSTTHR
ovlStartThreshold
Start threshold for Overload Handling within BSC. The value refer to TDPC processor
load, expressed as 100 * <TDPC processor
real-time> (e.g. 8000 means TDPC real-time = 80%).
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
NO
YES
1000 - 10000
8500
1000 - 10000
9500


A30808-X3247-M230-6-7619

1957
CML:BSC o
Id:0900d805800cecd5
OWR
overWrite
This parameter defines if the file present in the destination directory (DESTDIR param-
eter) ha to be overwritten or not.
Validity Range
Default Value
None.
Contained in the following commands:
UPLDFILE RSUDB, UPLHDCTR HDCTR
NO
YES


1958 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
p
PAGCOORCLB
pagingCoordinationClassB
Flag to enable/disable Paging coordination for Class B mobiles.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
PAGQOVLIND
pagingQueueOverflowIndication
This attribute allows the operator to define when the overload indication has to be sent
towards MSC and RC/LMT event logfile according to the percentage of number of
PAGING messages received in respect to the number of PAGING messages discarded
in a time period.
To set this parameter to a value different from 0 the bit 37 of the MNTBMASK must be
set to 1.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
PATHNAME
pathName
This parameter defines the pathname of the file which must be deleted.
Validity Range
Default Value
None.
DISABLED
ENABLED
DISABLED
0 - 100
0
1..59 characters string


A30808-X3247-M230-6-7619

1959
CML:BSC p
Id:0900d805800d85a3
Contained in the following commands:
DELETE FILEHANDLER GENFILE
PAVRLEV
pcAveragingLev
The PAVRLEV (Power Control Averaging Level) defines the
averaging parameters for the signal level measurements.
All the level-measurements concerning power-control pass an
averaging algorithm. The algorithm can be described as a window.
All values inside the window are used to calculate the arithmetic average.
The window is a queue: when a new measurement is received, the oldest measurement
is removed from the window.
The parameter used in the process are the averaging period (in SACCH periods) and
the DTX weighting factor.
The averaging period is the size of the window, the DTX weighting
factor determines how much more measurements with 'DTX not
active' (i.e. speech transmitted) are weighted than those with 'DTX
active' (i.e. no speech transmitted). For the latter case (DTX active)
the weighting factor is always '1'. The values entered for this
parameter are valid for both the uplink and downlink measurement.
This parameter consists of two mandatory fields: A_Lev_PC
(Averaging Level Power Control) and w_Lev_PC (Weighting Level Power Control).
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PAVRQUAL
pcAveragingQual
The PAVRQUAL (Power Control Averaging Parameters Quality) defines the averaging
parameters for the signal quality
measurements. All the quality-measurements concerning
power-control pass an averaging algorithm.
size 1 - 31 (unit of 1 SACCH multiframe, step size 1)
weight 1 - 3 (step size 1)
size 2
weight 2


1960 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
For the averaging principle, parameter format and parameter meaning please refer to
the explanation given for the previous
parameter PAVRLEV.
The values entered for this parameter are valid for both the uplink and downlink mea-
surement reports.
This parameter consists of two mandatory fields: A_Qual_PC
(Averaging Quality Power Control) and w_Qual_PC (Weighting Quality Power Control).
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PBGTHO
enablePowerBudgetHo
This attribute indicates whether handover due to power budget is enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
PCCCHLDI
periodCcchLoadIndication
This value indicates the frequency which the CCCH load indication is sent to the BSC.
The CCCH load indication is sent to BSC only when the threshold TCCCHLDI is
reached.
size 1 - 31 (unit of 1 SACCH multiframe, step size 1)
weight 1 - 3 (step size 1)
size 2
weight 2
TRUE
FALSE
TRUE


A30808-X3247-M230-6-7619

1961
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
PCMBSTXPRL
pcMaxBsTxPowerRedLev
This attribute defines the absolute maximum base station transmission power reduction
level (in 2dB steps).
Validity Range
Default Value
15
Contained in the following commands:
GET PWRC, SET PWRC
PCMCON<N>
pcmConnection<n>
This attribute indicates the third auxiliar PCM connection for the given BTSM (it is not
allowed for BS-82).
0 - 255 (1s step size)
255
0 - 15
<NULL>


1962 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
PcmbNumber PCMB_000
PCMB_001
PCMB_002
PCMB_003
PCMB_004
PCMB_005
PCMB_006
PCMB_007
PCMB_008
PCMB_009
PCMB_010
PCMB_011
PCMB_012
PCMB_013
PCMB_014
PCMB_015
PCMB_016
PCMB_017
PCMB_018
PCMB_019
PCMB_020
PCMB_021
PCMB_022
PCMB_023
PCMB_024
PCMB_025
PCMB_026
PCMB_027
PCMB_028
PCMB_029
PCMB_030
PCMB_031
PCMB_032
PCMB_033
PCMB_034


A30808-X3247-M230-6-7619

1963
CML:BSC p
Id:0900d805800d85a3
PCMB_035
PCMB_036
PCMB_037
PCMB_038
PCMB_039
PCMB_040
PCMB_041
PCMB_042
PCMB_043
PCMB_044
PCMB_045
PCMB_046
PCMB_047
PCMB_048
PCMB_049
PCMB_050
PCMB_051
PCMB_052
PCMB_053
PCMB_054
PCMB_055
PCMB_056
PCMB_057
PCMB_058
PCMB_059
PCMB_060
PCMB_061
PCMB_062
PCMB_063
PCMB_064
PCMB_065
PCMB_066
PCMB_067
PCMB_068
PCMB_069
PCMB_070


1964 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
PCMB_071
PCMB_072
PCMB_073
PCMB_074
PCMB_075
PCMB_076
PCMB_077
PCMB_078
PCMB_079
PCMB_080
PCMB_081
PCMB_082
PCMB_083
PCMB_084
PCMB_085
PCMB_086
PCMB_087
PCMB_088
PCMB_089
PCMB_090
PCMB_091
PCMB_092
PCMB_093
PCMB_094
PCMB_095
PCMB_096
PCMB_097
PCMB_098
PCMB_099
PCMB_100
PCMB_101
PCMB_102
PCMB_103
PCMB_104
PCMB_105
PCMB_106


A30808-X3247-M230-6-7619

1965
CML:BSC p
Id:0900d805800d85a3
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
PCMECH
powerControlMeasurementChannel
This attribute indicates where the mobile station shall measure the received power level
on the downlink for the purpose of the uplink power control.
PCMB_107
PCMB_108
PCMB_109
PCMB_110
PCMB_111
PCMB_112
PCMB_113
PCMB_114
PCMB_115
PCMB_116
PCMB_117
PortNumber PORT_0 (see Application Guidelines n. 4 and n. 5
of the CREATE:BTSM)
PORT_1
PORT_2
PORT_3
PORT_4
PORT_5
PORT_6
PORT_7
<NULL>
NULL


1966 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PCML
pcmLine
PCM line identity: it defines the LICD number, the circuit number and the trunk which the
pcm line is connected to.
Validity Range
In commands CREATE PCMB, CREATE PCMS, GET PCMB, GET PCMS:
In commands CREATE PCMG, GET PCMG:
Default Value
None.
Contained in the following commands:
CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMB, GET PCMG, GET
PCMS
PCMSN
pcmsNumber
This parameter identifies the PCM line on A-sub interface connected to TRAU.
Validity Range
Default Value
None.
MEABCCH means downlink measurements for power control shall
be made on BCCH;
MEAPDTCH means downlink measurements for power control shall
be made on PDCH.
MEABCCH
Licdn 0 - 9
Circn 0 - 5
Licdn 0 - 9
Circn 0 - 5 (0..3 for QTLP and 0..5 for STLP)
Trunk TRUNKA
TRUNKB
0 - 47


A30808-X3247-M230-6-7619

1967
CML:BSC p
Id:0900d805800d85a3
Contained in the following commands:
CREATE TRAU, GET TRAU
PCMSOBJ
relatedPcmsObject
This parameter specifies the PCMS line which the synchronization signal is derived
from.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE SYNC, GET SYNC
PCMT
pcmt
This parameter defines the TRAU number and the circuit number where the PCMA line
(PCM line of A interface) is connected to.
It consists of two mandatory fields: Traun and Circn.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCMA, GET PCMA
PCMTYPE
pcmType
This attribute specifies the maximum number of timeslots available of each PCM line.
0 - 47
Traun 0 - 47
Circn 0 - 3


1968 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
PCONINT
powerControlInterval
This attribute contains the minimum time period between two
successive modifications of the RF power level of one MS, i.e. before expiring of that
timer started after setting up a power command, new power control decision processes
are suspended.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PCRLFTH
pcRLFThreshold
This attribute defines the threshold value for the radio link counter for RLF warning
detection.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PCUID
pcuIdentifier
This attribute defines which PCU the FRL is connected to.
PCM30 (line with time slots from 0 to 31)
PCM24 (line with time slots from 1 to 24)
PCM30
0 - 31 unit of 2 SACCH multiframes
2
0 - 64 (1 SACCH multiframe step size)
18


A30808-X3247-M230-6-7619

1969
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
None.
Contained in the following commands:
CREATE FRL, GET FRL
PCUPRCSLD
pcuProcessorLoad
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBSC, GET QSMONBSC, SET QSMONBSC
PENTIME
penaltyTime
This attribute gives the duration for which the temporary offset is applied.
Validity Range
Default Value
0
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
PERM
permanent
This parameter can be equal to TRUE or FALSE.
Pathname
Pathname
<NULL>
NULL
0 - 31 (20s step size)
31: this value indicates that CellReselectOffset is sub-
tracted from C2 and temporaryOffset is ignored.
<NULL>


1970 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
If it is set equal to TRUE the patch is automatically loaded at the next "bring-up" opera-
tion; otherwise it is not loaded.
Validity Range
Default Value
Contained in the following commands:
CREATE RSUPCH, GET RSUPCH, SET RSUPCH
PERSTLVPRI<N>
persistenceLevelPriority<n>
This parameter is put in System Information in order to inform MS about Channel
Request/Packet Channel Request/EGPRS Packet Channel Request retransmission in
case of TBF with priority 1.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PERWEEK
periodWeekly
This attribute identifies a list of periods, one for every day of the week. Every period has
start time and stop time.
TRUE
FALSE
FALSE
0 - 15
5


A30808-X3247-M230-6-7619

1971
CML:BSC p
Id:0900d805800d85a3
Validity Range
all 0 - 0
weekly sunday noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
monday noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
tuesday noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
wednes-
day
noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
thursday noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
friday noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
saturday noSched 0 - 0
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23


1972 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Default Value
None.
Contained in the following commands:
CREATE CTRSCHED, CREATE HDCTR, GET CTRSCHED, GET HDCTR, SET
CTRSCHED, SET HDCTR
PFCBBHIPER
pFCBackgroundBucketHighPercentage
If PFC Bucket Level is greater than PFCBackgroundBucketHighPercentage*Back-
groundBucketMaxPCU, the Bucket Congestion is started.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCBBLPER
pFCBackgroundBucketLowPercentage
If PFC Bucket Level is lower than PFCBackgroundBucketHighPercentage*Background-
BucketMaxPCU, the Bucket Congestion is finished.
stopMinute 0 - 59
per_50
per_60
per_70
per_80
per_90
per_70


A30808-X3247-M230-6-7619

1973
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCBBMAPER
pFCBackgroundBucketMaxPercentage
This parameter reduces the value of Bmax automatically computed by BSC. BSC
criteria is BmaxPFC=PFCBBMAPER *Fn*(1sec+TF1)* Rgua, pfc) and Rgua,pfc guar-
anteed flow rate out of the buffer in the PCU.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_60


1974 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCBBMAPPER
pFCBackgroundBucketMaxPcuPercentage
This parameter assignes the value of Background Bucket Max PCU as percentage of
Bmax.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_90
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_100


A30808-X3247-M230-6-7619

1975
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCBRMAXU
pFCBackgroundRateMaxUsed
If the value is TRUE, Rmax is used for Bmax and R computation, otherwise RGUA is
used.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCBRPER
pFCBackgroundRatePercentage
This attribute is used in the Packet Flow Context (PFC) mechanism and it defines the
background rate percentage.
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_200
TRUE
FALSE
FALSE


1976 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCFCSUP
packetFlowContextFlowControlSupport
This parameter is used to indicate whether the Enhanced Flow Control is enabled or not.
This value is TRUE if BSC supports the Enhanced Flow Control.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_90
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_100


A30808-X3247-M230-6-7619

1977
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
PFCIBHIPER
pFCInteractiveBucketHighPercentage
If PFC Bucket Level is greater than PFCInteractiveBucketHighPercentage*Interactive-
BucketMaxPCU, the Bucket Congestion is started.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCIBLPER
pFCInteractiveBucketLowPercentage
If PFC Bucket Level is lower than PFCInteractiveBucketHighPercentage*Interactive-
BucketMaxPCU, the Bucket Congestion is finished.
TRUE
FALSE
FALSE
per_50
per_60
per_70
per_80
per_90
per_70


1978 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCIBMAPER
pFCInteractiveBucketMaxPercentage
This parameter reduces the value of Bmax automatically computed by BSC. BSC
criteria is BmaxPFC=PFCIBMAPER *Fn*(1sec+TF1)* Rgua, pfc) and Rgua,pfc guaran-
teed flow rate out of the buffer in the PCU.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_60


A30808-X3247-M230-6-7619

1979
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCIBMAPPER
pFCInteractiveBucketMaxPcuPercentage
This parameter assignes the value of Intercative Bucket Max PCU as percentage of
Bmax.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_90
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_100


1980 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCIRMAXU
pFCInteractiveRateMaxUsed
If the value is TRUE, Rmax is used for Bmax and R computation, otherwise RGUA is
used.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCIRPER
pFCInteractiveRatePercentage
This attribute is used in the Packet Flow Context (PFC) mechanism and it defines the
interactive rate percentage.
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_200
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1981
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSBHIPER
pFCStreamingBucketHighPercentage
If PFC Bucket Level is greater than PFCStreamingBucketHighPercentage*Streaming-
BucketMaxPCU, the Bucket Congestion is started.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_90
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_100


1982 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSBLPER
pFCStreamingBucketLowPercentage
If PFC Bucket Level is lower than PFCStreamingBucketHighPercentage*Streaming-
BucketMaxPCU, the Bucket Congestion is finished.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSBMAPER
pFCStreamingBucketMaxPercentage
This parameter reduces the value of Bmax automatically computed by BSC. BSC
criteria is BmaxPFC=PFCSBMAPER *Fn*(1sec+TF1)* Rgua, pfc) and Rgua,pfc guar-
anteed flow rate out of the buffer in the PCU.
per_50
per_60
per_70
per_80
per_90
per_70
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_60


A30808-X3247-M230-6-7619

1983
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSBMAPPER
pFCStreamingBucketMaxPcuPercentage
This parameter assignes the value of Streaming Bucket Max PCU as percentage of
Bmax.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_90
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_100


1984 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSRMAXU
pFCStreamingRateMaxUsed
If the value is TRUE, Rmax is used for Bmax and R computation, otherwise RGUA is
used.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSRPER
pFCStreamingRatePercentage
This attribute is used in the Packet Flow Context (PFC) mechanism and it defines the
streaming rate percentage.
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_200
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

1985
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PFCSUP
pfcSupport
This parameter allows the enabled/disabled of the Packet Flow Context procedure
support.
per_10
per_20
per_30
per_40
per_50
per_60
per_70
per_80
per_90
per_100
per_110
per_120
per_130
per_140
per_150
per_160
per_170
per_180
per_190
per_200
per_100


1986 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
PH
phase
This read-only parameter is used to identify the current loading phase.
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCOSUSW, GET BTSMOSUSW, GET TRAUOSUSW
PHYADDR
physicalAddress
This attribute identifies the physical address where to read data.
ENABLED
DISABLED
DISABLED
IDLE
LOAD_BACKUP_ESU_SW
LOAD_NEW_ESU_SW
ACCEPT_NEW_ESU_SW
WAIT_FOR_ACCEPT_NE
W_ESU_SW
LOAD_BACKUP_ESU_DB
LOAD_NEW_ESU_DB
SAVE_DB_IN_PROGRES
S
SYSTEM_INIT
DOWNLOAD_NE
ACTIVATE_NE
ALIGN_NE
ABORT_ALIGN_NE


A30808-X3247-M230-6-7619

1987
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
None.
Contained in the following commands:
MEMDUMP BSC
PKTMEASREPCNT
packetMeasurementReportCounter
This attribute indicates the number of consecutive serving cell's BCCH carrier mea-
surements under threshold NCC1TRSH , which are necessary to order a cell change.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PKTNDEC
packetNumberDecrement
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
H#0 - H#ffffffff (hexadecimal value)
1 - 10 (step 1)
1
This parameter defines the number of decrements for counter
N3102, performed if the T3182 expires without reception of packet
uplink ACK/NACK. It is used for RLC layer at MS side.
If PKTNDEC is set at zero the N3102 counter shall be disabled by
the mobile station.
0 - 7
2


1988 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
PKTNINC
packetNumberIncrement
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PKTNMA
packetNumberMax
This parameter defines the maximum value for counter N3102. If N3102 exceeds
PAKTNMA or N3102 reaches 0 or less than 0, a RLC abnormal release shall be per-
formed.
If PANDEC or PANINC or PKTNMA are set at zero the N3102 counter shall be disabled
by the mobile station.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PL
priorityLayer
The attribute defines the priority layer of the serving cell.
This parameter defines the number of increments for counter N3102
performed after receiving the packet uplink ACK/NACK. It is used for
RLC layer at MS side.
If PKTNINC is set at zero the N3102 counter shall be disabled by the
mobile station.
0 - 7
2
0 - 7
4


A30808-X3247-M230-6-7619

1989
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
PLMNP
plmnPermitted
The PLMNP (PLMN Permitted) parameter corresponds to the IE NCC Permitted.
The decimal value entered is sent to the MS as an 8-bit string on the BCCH
(SYS_INFO_Type 2) in order to indicate allowed NCCs for cell selection (idle) or on the
SACCH (SYS_INFO_Type6) in order to
indicate allowed NCCs for measurement reports (busy).
The 8-bit string is used as a bit-map; every '1' bit indicates that the NCC corresponding
to the bit position is allowed.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
PLNC
priorityLayerNCell
The attribute defines the priority layer of the neighbour cell (0 highest priority; 15 lowest
priority).
0 - 15 (0 highest priority, 15 lowest priority)
0
i
j
The value of the PLMNP is equal to the sum of i*2exp(j) where:
i = 0 or i = 1 is the value of a single bit
0 <= j <= 7 is the value of the position of the bit.
0 - 255
255


1990 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
PNOFACCH
periodNotificationFACCH
The attribute defines the period (repetition rate) for the FACCH notification for a given
ASCI call.
Validity Range
Default Value
5 = 2.5 sec
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
POOLTYP
PoolType
The attribute defines the type of the pool assigned to the given TSLA. For pool type
meaning see Appendix B: Tab. 6.14.
0 - 15
0
1.0 - 5.0 (0.5 sec step size)
<NULL>


A30808-X3247-M230-6-7619

1991
CML:BSC p
Id:0900d805800d85a3
Validity Range
POOL_NOTDEF
POOL_01
POOL_02
POOL_03
POOL_04
POOL_05
POOL_06
POOL_07
POOL_08
POOL_09
POOL_10
POOL_11
POOL_12
POOL_13
POOL_15
POOL_16
POOL_17
POOL_18
POOL_19
POOL_20
POOL_21
POOL_22
POOL_23
POOL_24
POOL_25
POOL_26
POOL_27
POOL_28
POOL_29
POOL_30
POOL_31
POOL_32
POOL_33
POOL_34
POOL_35


1992 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Default Value
POOL_NOTDEF
Contained in the following commands:
GET TSLA, SET TSLA
PORT<N>
port<n>
This parameter indicates the IP address for the PCU. The convention used for this value
is the dotted decimal format (e.g. "255.255.255.0").
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
PPLNC
penaltyPriorityLayerNCell
This parameter is relevant for speed sensitive handover; it
determines the temporary priority layer of the neighbour cell.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
POOL_42
POOL_43
POOL_44
POOL_45
POOL_46
POOL_47
POOL_48
7..15 characters string
<NULL>
NULL
0 - 15
0


A30808-X3247-M230-6-7619

1993
CML:BSC p
Id:0900d805800d85a3
PREAT
preallocationTimer
This parameter represents the timer guarding re-utilisation of pre-allocated resources
for Real Time Packet Flow Context (RTPFC).
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
PRIMARYIPADDR
primaryIpAddress
This attribute is the Ip address that is assigned to the Providing service MPCC port. The
RC and CBC always use this address when calling the BSC. The convention used for
his value is the well-known dotted decimal format (e.g. "172.31.21.88").
Validity Range
Default Value
None.
Contained in the following commands:
CREATE IPLI, GET IPLI, SET IPLI
PRIORITY
priority
This attribute assigns a priority to the script execution (0 = fastest,
10 = slowest).
Validity Range
Default Value
None.
Contained in the following commands:
EXEC LMT-INTERNAL, SET LMT-INTERNAL
1 - 100 (unit 100ms)
20
7..15 characters string
0 - 10


1994 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
PRIOSLOTN
prioritySlotNumber
This attribute stores an integer value; at bring up, the loading sequence of the patches
will be determined by sorting the patches in function of the slot number.
The default value <NULL> is valid for the unpatches; a value which will cause the patch
to be loaded after the ones currently created (i.e. the current maximum slot number plus
one) for the patches.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RSUPCH, GET RSUPCH, SET RSUPCH
PROCTYP
processorType
This field identifies the processor type for the file to be transferred in the BSC disk.
Validity Range
Default Value
None.
Contained in the following commands:
GET RSUEXE
0 - 65000
<NULL>
BSCI SWLH
IXLT GENERICE
XE
TDPC MSCI
DSP ACTAM
ALCO BBSIG
CCTRL CCLK
LI TRXA
TRAC TRXD
VAMBSC VAMBTSE
VAMTRAU PPXL
PPXU MPCC


A30808-X3247-M230-6-7619

1995
CML:BSC p
Id:0900d805800d85a3
PROCTYPE
processorType
This field identifies the processor type on which the patch has been installed.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RSUPCH , GET RSUPCH
PRPBCCH
powerReductionOnPbcch
This attribute indicates the power reduction value used by the BTS on PBCCH blocks,
relative to the output power used on BCCH.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
PVC
pvc
This read-only parameter defines the number of PVCs, included in the X25A and X25D
configuration message (IXLT restart).
PPCU
TDPC
PPXL
PPXU
MPCC
PPXP
PPXT
0 - 15 (-2 dB step size)
0


1996 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
0
Contained in the following commands:
GET X25A, GET X25D
PWRCONF
powerConfirm
This attribute defines the maximum interval for confirmation of the new RF power level
in units of two SACCH multiframes.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PWREDSS
powerRedStepSize
This attribute defines the step size used when reducing the MS transmit power.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PWRINCSS
powerIncrStepSize
This attribute defines the step size used when increasing the MS transmit power.
0 - 4095
1 - 31 (unit of 2 SACCH multiframes)
2
db2
db4
db2


A30808-X3247-M230-6-7619

1997
CML:BSC p
Id:0900d805800d85a3
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
PWROFS
powerOffset
This parameter defines the additional power to MS on RACH access.The attribute is
meaningless for all the cells not DCS1800.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
PWROUT
powerOutputThresholds
db2
db4
db6
db6
0 - 3 (unit of dB, step size 2 dB)
0
This attribute defines the three power output thresholds:
- oPwrFaultThreshold: defines the minimal output power level
"transmitter-fault" which results in generating an alarm to the
CCTRL.
- redOutPwrThreshold: defines the power level when a warning
is generated.
- excesOutPwrThresh: defines the power level when a major
alarm is generated due to too much power level at the PA
output.


1998 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d85a3
p
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
PWRRED
txPwrMaxReduction
This attribute specifies the number of 2 dB steps the TX power should be reduced from
the maximum transmit power, for tuning the cell coverage. The resulting attenuated
transmit power is the maximum nominal power Pn.
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
oPwrFaultThreshold m10db
m8db
redOutPwrThresh-
old
m10db
m8db
m6db
m4db
excesOutPwrThresh db3
db5
oPwrFaultThreshold m10db
redOutPwrThresh-
old
m6db
excesOutPwrThresh db5
0 - 6 (2 dB step size)
6


A30808-X3247-M230-6-7619

1999
CML:BSC q
Id:0900d805800cecdc
q
QLPUB
queuingLengthPublic
This attribute specifies the maximum number of TCH requests that can be queued in the
Public area in the cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
QLWPS
queuingLengthWPS
This attribute specifies the maximum number of TCH requests that can be queued in the
WPS area in the cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
QSRHC
qSearchC
This attribute defines a threshold which enables the searching for 3G cells in case of
handover measurements on other radio access
technologies.
1 - 100
50
0 - 100
0


2000 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecdc
q
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
QSRHCINI
qSearchCinitial
This attribute indicates the value to be used before the Qsearch_c value is received in
measurement information message.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
UMDB98
UMDB94
UMDB90
UMDB86
UMDB82
UMDB78
UMDB74
ALWAYS
OMDB78
OMDB74
OMDB70
OMDB66
OMDB62
OMDB58
OMDB54
NEVER
NEVER
QSEARCHI
ALWAYS
QSEARCHI


A30808-X3247-M230-6-7619

2001
CML:BSC q
Id:0900d805800cecdc
QSRHI
qSearchI
This attribute defines a threshold which enables the searching for 3G cells with regard
to cell reselection; it has to be handled because it is the default value of the attribute
QSRHCINI (qSearchCinitial).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
QSRHPRI
qSearchPriority
This parameter defines a threshold and it indicates if the
measurements have to be made by mobile when the signal is under or above the thresh-
old; the value is expressed in dB.
UMDB98
UMDB94
UMDB90
UMDB86
UMDB82
UMDB78
UMDB74
ALWAYS
OMDB78
OMDB74
OMDB70
OMDB66
OMDB62
OMDB58
OMDB54
NEVER
NEVER


2002 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecdc
q
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
QUALLEVHOM
qualLevelHoMargin
This parameter defines the margin by which the DL power level of a target cell shall
exceed the DL power level of the serving cell to be entered into the target cell list in case
of a quality HO.
UMDB98
UMDB94
UMDB90
UMDB86
UMDB82
UMDB78
UMDB74
ALWAYS
OMDB78
OMDB74
OMDB70
OMDB66
OMDB62
OMDB58
OMDB54
NEVER
ALWAYS


A30808-X3247-M230-6-7619

2003
CML:BSC q
Id:0900d805800cecdc
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
0 - 126 where:
0 = -63 dB
1 = -62 dB
..
..
125 = +62 dB
126 = + 63 dB
69


2004 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
r
R20
restartRequestRetryCount
Restart request retry count.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
R22
resetRequestRetryCount
Reset request retry count.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
R23
clearRequestRetryCount
Clear request retry count.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
1 - 255
3
1 - 255
3
1 - 255
3


A30808-X3247-M230-6-7619

2005
CML:BSC r
Id:0900d805800d6b75
RAARET
randomAccessRetry
This parameter is no more relevant for the system.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
RACHBT
rachBusyThreshold
This attribute defines a threshold for the received signal level during network access and
handover access. A signal level exceeding this threshold is interpreted as a busy RACH
or a busy FACCH (when transmitting CHANNEL REQUEST (RACH) or Handover
ACCESS (FACCH)).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
RACHLAS
rachLoadAveragingSlots
This attribute defines the number of RACH bursts over which RACH measurements are
performed.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TRUE
FALSE
TRUE
0 - 127 (-1 dbm step size)
109
102 - 65535
204


2006 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
RACODE
routingAreaCode
This attribute represents the identification of the RA which this cell belongs to.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PTPPKF, CREATE TGTPTPPKF, GET PTPPKF, GET TGTPTPPKF, SET
PTPPKF, SET TGTPTPPKF
RACOL
routingAreaColour
This attribute is used by the mobile to identify the specific routing area.
Validity Range
Default Value
0
Contained in the following commands:
CREATE PTPPKF, CREATE TGTPTPPKF, GET PTPPKF, GET TGTPTPPKF, SET
PTPPKF, SET TGTPTPPKF
RADIOMG
radioMeasGran
This attribute specifies the granularity in which the radio
measurements have to be transmitted on the A-bis interface in case they are enabled.
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
RADIOMR
radioMeasRep
0 - 255
0 - 7
1 - 254 (1 SACCH multiframes step size)
254


A30808-X3247-M230-6-7619

2007
CML:BSC r
Id:0900d805800d6b75
This parameter specifies whether the radio measurements have to be transmitted on the
A-bis interface.
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
RAENV
radioEnvironment
This parameter specifies the radio environment in the cell. It is an
indicator of user mobility. Two values are possible:
LOWDIV (lowDiversity): it means that for a MS radio conditions can change slowly,
because the cell is characterized by low user mobility (pico cells, indoor cells, or MSs
have a speed lower than 50 km/h).
HIGHDIV (highDiversity): it means that for a MS radio conditions can change fast,
because MSs have a speed higher than 50 km/h.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
RARESH
routingAreaReselectHysteresis
This parameter indicates the additional hysteresis to be subtracted from C32, when the
mobile is selecting a cell in a new Routing Area (RA).
OFF
ON
OFF
LOWDIV
HIGHDIV
HIGHDIV


2008 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
RAVEW
rateAveragingWindow
The attribute specifies the averaging window size, in SACCH periods, (how many mea-
surement samples) used in the gliding averaging process for rate up-downgrading for
14.4 kbit/s data services.
Validity Range
Default Value
8
Contained in the following commands:
GET HAND, SET HAND
RDGRDL
rateDowngradeDownlink
Validity Range
Default Value
2
Contained in the following commands:
GET HAND, SET HAND
0 - 7 (2 dB step size)
2
4 - 32
<NULL>
Downgrade threshold (14.4 kbit/s -> 9.6 kbit/s)
for downlink direction.
1 - 6 For the values make references to Appendix B: Group 3.
<NULL>


A30808-X3247-M230-6-7619

2009
CML:BSC r
Id:0900d805800d6b75
RDGRUL
rateDowngradeUplink
Validity Range
Default Value
2
Contained in the following commands:
GET HAND, SET HAND
RDLNKTBS
radioLinkTimeoutBs
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
Downgrade threshold (14.4 kbit/s -> 9.6 kbit/s)
for uplink direction.
1 - 6 For the values make references to Appendix B: Group 3.
<NULL>
The radioLinkTimeout attribute is used to indicate the maximum
value of the radio link counter needed to detect a radio link failure in
the BS.
The radio link failure criterion is based on the radio link counter
called 'S'. If the BS is unable to decode a SACCH message, S is
decreased by 1, while in the case of a successful reception of a
SACCH message, S is increased by 2. In any case, S shall not
exceed the value of RDLNKTBS. If S reaches 0, a radio link failure
shall be signalled to BSC.
4 - 64 (step size 4)
20


2010 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
RDLNKTO
radioLinkTimeout
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
RECCRI
recordCriteria
This attribute specifies the criteria in which the trace are collected in the BSC.
Validity Range
Default Value
Contained in the following commands:
CREATE TRACE, GET TRACE
RECINT
recordingInterval
This parameter specifies the type of periods (recording intervals) in which scanner must
be activated.
The radioLinkTimeout attribute is used to indicate the maximum
value of the radio link counter needed to detect a radio link failure.
This value is used by the MS procedure and may also be used for
the BSS procedure. This attribute corresponds to the radio sub-
system link control parameter RADIO_LINK_TIMEOUT. The radio
link failure criterion is based on the radio link counter called 'S'. If the
MS is unable to decode a SACCH message, S is decreased by 1,
while in the case of a successful reception of a SACCH message, S
is increased by 2. In any case, S shall not exceed the value of
RADIO_LINK_TIMEOUT. If S reaches 0, a radio link failure shall be
declared. The radio-link-timeout parameter ranges from 4 to 64
SACCH blocks at steps of 4 SACCH blocks.
Note that S=4+RDLNKTO*4.
0 - 15
4
NO_CRITERIA
NO_CRITERIA


A30808-X3247-M230-6-7619

2011
CML:BSC r
Id:0900d805800d6b75
Validity Range
daily 1 to 7 items of
startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
weekly sunday period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0
monday period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0
tuesday period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0
wednes-
day
period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0
thursday period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0
friday period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0


2012 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
Default Value
all
Contained in the following commands:
CREATE SCANBSC, CREATE SCANBTS, CREATE SCANBTSE, CREATE SCAN-
BTSIHO, CREATE SCANBTSM, CREATE SCANBTSOHOI, CREATE SCANBTSO-
HON, CREATE SCANBTSOHOS, CREATE SCANCHAN, CREATE SCANCTRX,
CREATE SCANFBTSM, CREATE SCANGPRS, CREATE SCANSS7L, CREATE
SCANTRX, GET SCANBSC, GET SCANBTS, GET SCANBTSE, GET SCAN-
BTSIHO, GET SCANBTSM, GET SCANBTSOHOI, GET SCANBTSOHON, GET
SCANBTSOHOS, GET SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET
SCANGPRS, GET SCANSS7L, GET SCANTRX, SET SCANBSC, SET SCANBTS,
SET SCANBTSE, SET SCANBTSIHO, SET SCANBTSM, SET SCANBTSOHOI, SET
SCANBTSOHON, SET SCANBTSOHOS, SET SCANCHAN, SET SCANCTRX, SET
SCANFBTSM, SET SCANGPRS, SET SCANSS7L, SET SCANTRX
RELCMD
relatedCommand
This parameter describes the command on the new attributes; only SET and GET
commands are valid. At the creation of an instance of RELOBJ MOC the BSC assigns
to the new attributes their default value.
Validity Range
Default Value
None.
Contained in the following commands:
BRIDGE BSC
RELF
relatedFiles
This attribute univocally identifies a physical file on the BSC disk. The file can be:
- a software load header file (related to a RSUSWLH object instance)
- an executable file (related to a RSUEXE object instance)
saturday period startHour 0 - 23
startMinute 0 - 59
stopHour 0 - 23
stopMinute 0 - 59
noSched 0 - 0
all 0 - 0
SET
GET


A30808-X3247-M230-6-7619

2013
CML:BSC r
Id:0900d805800d6b75
- a database file (related to a RSUDB object instance)
- a patch file (related to a RSUPCH object instance).
After the download procedure (i.e. after the CREATE command of a RSU object
instance), the relatedFiles field of the created RSU object instance contains the com-
pleted path of the physical file stored on BSC disk.
Validity Range
In commands GET RSUSWLH:
In commands GET RSUDB, GET RSUEXE, GET RSUPCH:
Default Value
None.
Contained in the following commands:
GET RSUDB, GET RSUEXE, GET RSUPCH, GET RSUSWLH
RELOBJ
relatedObject
This parameter describes the RDN of the object.
Validity Range
Default Value
None.
Contained in the following commands:
BRIDGE BSC
RELRSU
relatedRSU
This read-only parameter defines the instance of Reusable Software Unit DB that is
related to the BSC Executable Software Unit DB.
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCESUDB, GET BSCESUSW, GET NEYESUSW
0..59 characters string
1..59 characters string
Pathname
Pathname


2014 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
REMAL
remoteAlarmType
Remote alarm type. This attribute is significative only for PCM24 lines.
Validity Range
Default Value
CCITT
Contained in the following commands:
CREATE PCMA, CREATE PCMB, CREATE PCMG, CREATE PCMS, GET PCMA,
GET PCMB, GET PCMG, GET PCMS, SET PCMB, SET PCMG, SET PCMS
REPTYP
reportType
This attribute indicates to the mobile to use the ENHANCED MEASUREMENT
REPORT or MEASUREMENT REPORT messages for measurements reporting.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
REQATTL
listOfRequiredAttributes
This parameter defines the list of the attributes whose status or value can be displayed
by the operator.
Validity Range
In commands GET BSCESUSW:
CCITT
BELLCORE
<NULL>
ENHANCED
NORMAL
NORMAL
1 to 3 items of
ULAB
VER
RELRSU


A30808-X3247-M230-6-7619

2015
CML:BSC r
Id:0900d805800d6b75
In commands GET RSUSWLH:
In commands GET RSUPCH:
In commands GET RSUEXE:
In commands GET RSUDB:
In commands GET BSCESUDB:
In commands GET NEYESUSW:
1 to 4 items of
ULAB
VER
NTWEL
RELF
1 to 5 items of
ULAB
PROCTYPE
PERM
PRIOSLOTN
RELF
1 to 3 items of
VER
PROCTYP
RELF
1 to 3 items of
ULAB
RELF
DBVER
1 to 3 items of
ULAB
RELRSU
DBVER
1 to 4 items of
ULAB
VER
NTWEL
RELRSU


2016 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
Default Value
None.
Contained in the following commands:
GET BSCESUDB, GET BSCESUSW, GET NEYESUSW, GET RSUDB, GET
RSUEXE, GET RSUPCH, GET RSUSWLH
RETRY
retryNumber
Retry Number.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
RFRSINDP
rfResourceIndicationPeriod
This attribute defines the sending rate of the radio signalling message RFRESIND to the
BSC.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
RHOLTQDL
rateHoLowerThresholdQualDownlink
The attribute defines the receive signal quality threshold on downlink for handover
decision for data calls where the rate up/downgrading mechanism is applied.
1 - 254
8
1 - 254 (1 SACCH multiframes step size)
60


A30808-X3247-M230-6-7619

2017
CML:BSC r
Id:0900d805800d6b75
Validity Range
Default Value
3
Contained in the following commands:
GET HAND, SET HAND
RHOLTQUL
rateHoLowerThresholdQualUplink
The attribute defines the receive signal quality threshold on uplink for handover decision
for data calls where the rate up/downgrading mechanism is applied.
Validity Range
Default Value
3
Contained in the following commands:
GET HAND, SET HAND
RMTIPEP
remoteIPEndpoint
This parameter indicates the remote IP endpoint.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RNSVLIP, GET RNSVLIP, SET RNSVLIP
RNCID
rncId
This attribute identifies the RNC containing the UMTS cell.
2 - 7 For the values make references to Appendix B: Group 3.
<NULL>
2 - 7 For the values make references to Appendix B: Group 3.
<NULL>
ipAddress 7..15 characters
string
udpPort 1024 - 65535


2018 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
Validity Range
Default Value
0
Contained in the following commands:
CREATE TGTFDD, CREATE TGTTDD, GET TGTFDD, GET TGTTDD, SET
TGTFDD, SET TGTTDD
ROUIPADD<N>
routerIPAddress<n>
This attribute indicates the Router IP address associated to all PCU port 0. The conven-
tion used for this value is the dotted decimal format (e.g. "172.31.21.88").
Note: The attributes ROUIPADD0, ROUIPADD1, SUBNETMASK0, SUBNETMASK1
are necessary only if SGSN is connected to BSC via router. If the router is not present,
these attributes must be set to <NULL>.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
RUGRDL
rateUpgradeDownlink
Upgrade threshold (9.6 kbit/s -> 14.4 kbit/s) for downlink direction.
Validity Range
Default Value
1
Contained in the following commands:
GET HAND, SET HAND
0 - 4095
7..15 characters string
<NULL>
NULL
0 - 5 For the values make references to Appendix B: Group 3.
<NULL>


A30808-X3247-M230-6-7619

2019
CML:BSC r
Id:0900d805800d6b75
RUGRUL
rateUpgradeUplink
Upgrade threshold (9.6 kbit/s -> 14.4 kbit/s) for uplink direction.
Validity Range
Default Value
1
Contained in the following commands:
GET HAND, SET HAND
RUNESU
runningESU
This read-only parameter defines the currently running ESU
(Executable Software Unit).
Validity Range
Default Value
None.
Contained in the following commands:
GET BSCOSUDB, GET BSCOSUSW, GET BTSMOSUSW, GET TRAUOSUSW
RXLEVAMI
rxLevAccessMin
This parameter is used in order to evaluate the path loss criterion parameter C1 of a cell.
It indicates the minimum received level at the MS required for the access to the system.
The value is an integer number in the range 0 to 63.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
0 - 5 For the values make references to Appendix B: Group 3.
<NULL>
<ANY>
<NULL>
0 - 63 For the values make references to Appendix B: Group 2.
6


2020 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
RXLEVHO
enableRxLevHo
This attribute indicates whether handover due to uplink or downlink received low level is
enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
RXLEVMIN
rxLevMinCell
This attribute holds the minimum received signal strength in a cell for a MS to be handed
over to that cell. It is the minimum RXLEV
(Reception Level) required from an MS to perform the handover to adjacent cell "adjcn".
This parameter is used in the handover
preprocessing function.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
RXLEVMINC
rxLevMinCell
This attribute holds determines the minimum received signal level the adjacent UMTS
cell must provide to be regarded as suitable target cell for handover.
The parameter is coded according to the following table:
TRUE
FALSE
TRUE
0 - 63 For the values make references to Appendix B: Group 2.
12
0 RSCP < -115 dBm
1 -115 dBm <= RSCP <-114 dBm
... ...
62 -54 dBm <= RSCP < -53 dBm
63 -53 dBm <= RSCP


A30808-X3247-M230-6-7619

2021
CML:BSC r
Id:0900d805800d6b75
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
RXLV
rxLevel
This attribute specifies above which level RXLEV values are taken into account.
Validity Range
Default Value
Contained in the following commands:
CREATE RFLOOP, GET RFLOOP, SET RFLOOP
RXLVR
rxLevRanges
0 - 63
5 for FDD, 15 for TDD
1 - 62
10
This parameter requires 7 input values which define the 8 ranges for
RXLEVred (Input_value1, Input_value2....Input_value7); the
input_values are defined by means of the "rangeBound<n>" fields
(<n>=1..7) of the RXLEV_RED parameter. The allowed input values
for RXLEV are 0 to 63, as defined in GSM.
The correspondence between the Input_values, RXLED_RED and
RXLEV is the following:
RXLEV_RED_Range0: RXLEV<= Inputvalue1
RXLEV_RED_Range1:Input_value
1
<RXLEV<= Inputvalue2
RXLEV_RED_Range2:Input_value
2
<RXLEV<= Inputvalue3
RXLEV_RED_Range3:Input_value
3
<RXLEV<= Inputvalue4
RXLEV_RED_Range4:Input_value
4
<RXLEV<= Inputvalue5
RXLEV_RED_Range5:Input_value
5
<RXLEV<= Inputvalue6


2022 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6b75
r
Validity Range
Default Value
Contained in the following commands:
CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX
RXQUALHO
enableRxQualHo
This attribute indicates whether handover due to bad uplink or
downlink received quality is enabled or disabled.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
RXLEV_RED_Range6:Input_value
6
<RXLEV<= Inputvalue7
RXLEV_RED_Range7:Input_value
7
<RXLEV
rangeBound1 0 - 63
rangeBound2 0 - 63
rangeBound3 0 - 63
rangeBound4 0 - 63
rangeBound5 0 - 63
rangeBound6 0 - 63
rangeBound7 0 - 63
rangeBound1 7
rangeBound2 15
rangeBound3 23
rangeBound4 31
rangeBound5 39
rangeBound6 47
rangeBound7 55
TRUE
FALSE
TRUE


A30808-X3247-M230-6-7619

2023
CML:BSC s
Id:0900d805800d6c0e
s
SALUNAME
salesUniqueName
This attribute defines every Network Element by its unique name. When it appears in
the BTSM and TRAU commands, it is used during the network element alignment phase
to verify its identity.
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, CREATE TRAU, GET BSCE, GET BTSM, GET TRAU, SET BSCE,
SET BTSM, SET TRAU
SANTIME
sanityTimer
Sanity timer to control the Level 2 Processor outage. Value 0 means timer disabled.
Validity Range
Default Value
10
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
SANUNIT
sanityUnit
This read-only parameter defines the measurement unit for the SANTIME timer.
Validity Range
Default Value
None.
0..11 characters string
"NOT_DEFINED"
0 - 255 hundreds of milliseconds
MS100 msec unit
HLFSEC
SEC5


2024 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Contained in the following commands:
GET OPC
SCHWEIPRI1
schedulingWeightOfPriority1
This field indicates the scheduling weight associated to scheduling priorities 1.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
SCHWEIPRI2
schedulingWeightOfPriority2
This field indicates the scheduling weight associated to scheduling priorities 2.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
SCHWEIPRI3
schedulingWeightOfPriority3
This field indicates the scheduling weight associated to scheduling priorities 3.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
1 - 16
8
1 - 16
4
1 - 16
2


A30808-X3247-M230-6-7619

2025
CML:BSC s
Id:0900d805800d6c0e
SCHWEIPRI4
schedulingWeightOfPriority4
This field indicates the scheduling weight associated to scheduling priorities 4.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
SDCCHCONGTH
sdcchCongestionThreshold
This parameter represents the threshold which is set on a per cell basis and moves sub-
channels from the TCHSDPOOL (see CHPOOLTYP parameter) to the
SDCCH_BACKUP_POOL.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
SDCCHDROR
sDCCHDropRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
1 - 16
1
70 - 100
<NULL>
Pathname
<NULL>
NULL


2026 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
SDCCHLOSR
sDCCHLossRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
SECONDARYIPADDR
secondaryIpAddress
This attribute is the Ip address that is assigned to the standby MPCC port. The RC and
CBC will never use this address when calling the BSC. It will be used in order to perform
the periodical Ip link test. The convention used for this value is the well-known dotted
decimal format (e.g. "172.31.21.88").
Validity Range
Default Value
None.
Contained in the following commands:
CREATE IPLI, GET IPLI, SET IPLI
SG10HOPAR
sg10HandoverParms
This attribute specifies the set of Handover parameters for Service Group 10. For the
parameters make reference to Tab. 6.19 of Appendix B: Group 7.
Pathname
<NULL>
NULL
7..15 characters string


A30808-X3247-M230-6-7619

2027
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG10PCPAR
sg10PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 10. For
the parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
rateHoLower-
ThresholdQualDL
2 - 7
rateHoLower-
ThresholdQualUL
2 - 7
<NULL>
NULL


2028 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2029
CML:BSC s
Id:0900d805800d6c0e
SG11HOPAR
sg11HandoverParms
This attribute specifies the set of Handover parameters for Service Group 11. For the
parameters make reference to Tab. 6.20 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG11PCPAR
sg11PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 11. For
the parameters make reference to Tab. 6.23 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThr-
esQualAMRDL
0 - 20
hoLowerThr-
esQualAMRUL
0 - 20
hoThresAMRCom-
prDL
0 - 20
hoThresAMRCom-
prUL
0 - 20
<NULL>
NULL


2030 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThr-
esQualAMRDL
0 - 20
PcLowerThr-
esQualAMRUL
0 - 20
PcUpperThr-
esQualAMRDL
0 - 20
PcUpperThr-
esQualAMRUL
0 - 20
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2031
CML:BSC s
Id:0900d805800d6c0e
SG12HOPAR
sg12HandoverParms
This attribute specifies the set of Handover parameters for Service Group 12. For the
parameters make reference to Tab. 6.20 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG12PCPAR
sg12PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 12. For
the parameters make reference to Tab. 6.23 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThr-
esQualAMRDL
0 - 20
hoLowerThr-
esQualAMRUL
0 - 20
hoThresAMRCom-
prDL
0 - 20
hoThresAMRCom-
prUL
0 - 20
<NULL>
NULL


2032 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThr-
esQualAMRDL
0 - 20
PcLowerThr-
esQualAMRUL
0 - 20
PcUpperThr-
esQualAMRDL
0 - 20
PcUpperThr-
esQualAMRUL
0 - 20
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2033
CML:BSC s
Id:0900d805800d6c0e
SG13HOPAR
sg13HandoverParms
This attribute specifies the set of Handover parameters for Service Group 13. For the
parameters make reference to Tab. 6.21 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG13PCPAR
sg13PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 13. For
the parameters make reference to Tab. 6.23 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThr-
esQualAMRDL
0 - 20
hoLowerThr-
esQualAMRUL
0 - 20
hoThresAMRDe-
comprDL
0 - 20
hoThresAMRDe-
comprUL
0 - 20
<NULL>
NULL


2034 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThr-
esQualAMRDL
0 - 20
PcLowerThr-
esQualAMRUL
0 - 20
PcUpperThr-
esQualAMRDL
0 - 20
PcUpperThr-
esQualAMRUL
0 - 20
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2035
CML:BSC s
Id:0900d805800d6c0e
SG14HOPAR
sg14HandoverParms
This attribute specifies the set of Handover parameters for Service Group 14. For the
parameters make reference to Tab. 6.21 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG14PCPAR
sg14PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 14. For
the parameters make reference to Tab. 6.23 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThr-
esQualAMRDL
0 - 20
hoLowerThr-
esQualAMRUL
0 - 20
hoThresAMRDe-
comprDL
0 - 20
hoThresAMRDe-
comprUL
0 - 20
<NULL>
NULL


2036 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThr-
esQualAMRDL
0 - 20
PcLowerThr-
esQualAMRUL
0 - 20
PcUpperThr-
esQualAMRDL
0 - 20
PcUpperThr-
esQualAMRUL
0 - 20
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2037
CML:BSC s
Id:0900d805800d6c0e
SG1HOPAR
sg1HandoverParms
This attribute specifies the set of Handover parameters for Service Group 1. For the
parameters make reference to Tab. 6.16 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG1PCPAR
sg1PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 1. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
<NULL>
NULL


2038 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2039
CML:BSC s
Id:0900d805800d6c0e
SG2HOPAR
sg2HandoverParms
This attribute specifies the set of Handover parameters for Service Group 2. For the
parameters make reference to Tab. 6.16 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG2PCPAR
sg2PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 2. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
<NULL>
NULL


2040 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2041
CML:BSC s
Id:0900d805800d6c0e
SG3HOPAR
sg3HandoverParms
This attribute specifies the set of Handover parameters for Service Group 3. For the
parameters make reference to Tab. 6.16 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG3PCPAR
sg3PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 3. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDl
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
hoThresholdEFR-
ComprDL
0 - 20
hoThresholdEFR-
ComprUL
0 - 20
hoThresholdFR-
ComprDL
0 - 20
hoThresholdFR-
ComprUL
0 - 20
<NULL>
NULL


2042 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2043
CML:BSC s
Id:0900d805800d6c0e
SG4HOPAR
sg4HandoverParms
This attribute specifies the set of Handover parameters for Service Group 4. For the
parameters make reference to Tab. 6.16 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG4PCPAR
sg4PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 4. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDl
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
hoThresholdEFR-
ComprDL
0 - 20
hoThresholdEFR-
ComprUL
0 - 20
hoThresholdFR-
ComprDL
0 - 20
hoThresholdFR-
ComprUL
0 - 20
<NULL>
NULL


2044 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2045
CML:BSC s
Id:0900d805800d6c0e
SG5HOPAR
sg5HandoverParms
This attribute specifies the set of Handover parameters for Service Group 5. For the
parameters make reference to Tab. 6.16 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG5PCPAR
sg5PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 5. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
hoThresholdHRDe-
comprDL
0 - 20
hoThresholdHRDe-
comprUL
0 - 20
<NULL>
NULL


2046 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2047
CML:BSC s
Id:0900d805800d6c0e
SG6HOPAR
sg6HandoverParms
This attribute specifies the set of Handover parameters for Service Group 6. For the
parameters make reference to Tab. 6.16 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG6PCPAR
sg6PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 6. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
hoThresholdHRDe-
comprDL
0 - 20
hoThresholdHRDe-
comprUL
0 - 20
<NULL>
NULL


2048 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2049
CML:BSC s
Id:0900d805800d6c0e
SG7HOPAR
sg7HandoverParms
This attribute specifies the set of Handover parameters for Service Group 7. For the
parameters make reference to Tab. 6.19 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG7PCPAR
sg7PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 7. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
rateHoLower-
ThresholdQualDL
2 - 7
rateHoLower-
ThresholdQualUL
2 - 7
<NULL>
NULL


2050 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2051
CML:BSC s
Id:0900d805800d6c0e
SG8HOPAR
sg8HandoverParms
This attribute specifies the set of Handover parameters for Service Group 8. For the
parameters make reference to Tab. 6.19 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG8PCPAR
sg8PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 8. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
rateHoLower-
ThresholdQualDL
2 - 7
rateHoLower-
ThresholdQualUL
2 - 7
<NULL>
NULL


2052 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2053
CML:BSC s
Id:0900d805800d6c0e
SG9HOPAR
sg9HandoverParms
This attribute specifies the set of Handover parameters for Service Group 9. For the
parameters make reference to Tab. 6.19 of Appendix B: Group 7.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
SG9PCPAR
sg9PowerControlParms
This attribute specifies the set of Power Control parameters for Service Group 9. For the
parameters make reference to Tab. 6.22 of Appendix B: Group 7.
hoLowerThreshold-
LevDL
0 - 63
hoLowerThreshold-
LevUL
0 - 63
hoThreshold-
LevDLintra
0 - 63
hoThresholdLe-
vULintra
0 - 63
hoRxlevDLinner 0 - 63
hoRxlevDLouter 0 - 63
hoLowerThreshold-
QualDL
0 - 7
hoLowerThreshold-
QualUL
0 - 7
rateHoLower-
ThresholdQualDL
2 - 7
rateHoLower-
ThresholdQualUL
2 - 7
<NULL>
NULL


2054 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
EnableBSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnableMSPower-
Control
DISABLED
CLASSIC
ADAPTIVE
EnablePowerCon-
trolRLFW
TRUE
FALSE
PcLowerThreshold-
LevDL
0 - 63
PcLowerThreshold-
LevUL
0 - 63
PcUpperThreshold-
LevDL
0 - 63
PcUpperThreshold-
LevUL
0 - 63
PcRLFThreshold 0 - 64
PcLowerThreshold-
QualDL
0 - 7
PcLowerThreshold-
QualUL
0 - 7
PcUpperThreshold-
QualDL
0 - 7
PcUpperThreshold-
QualUL
0 - 7
PcRadioLinkTime-
OutBs
0 - 15 in unit of 4 SACCH multiframes, step size
4
PcRadioLinkTime-
OutMs
0 - 15 in unit of 4 SACCH multiframes, stepsize 4
<NULL>
NULL


A30808-X3247-M230-6-7619

2055
CML:BSC s
Id:0900d805800d6c0e
SHLAPDIT
shortLapdIntTimer
This parameter is used by the BSC to calculate the value of timer T202 which is used
for the TEI assignment procedure.
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
SIMSCREL99
systemInfoMscRel99
When the value of this attribute changes the system information 3 is updated and resent
on all cells belonging to the BSC to inform MSs about MSC release. This new procedure
is allowed only with release 99 or onwards MSC.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
SISGSNREL99
systemInfoSgsnRelease99
This attribute is used to inform MS about SGSN capabilities. Possible values are:
FALSE, i.e. SGSN is aligned to a version earlier than Release 99;
TRUE, i.e. SGSN is aligned to Release 99 version.
3 - 20 (1 sec step size)
15
TRUE
FALSE
TRUE


2056 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
SLAPDOVLTH
secondLapdOverloadThreshold
Validity Range
Default Value
Contained in the following commands:
CREATE BTSM, GET BTSM, SET BTSM
SLC
signallingLinkCode
The Signalling Link Code is a logical number which identifies the signalling link.
Validity Range
Default Value
None.
TRUE
FALSE
TRUE
This attribute indicates the second level thresholds (in percentage)
of the BTSE Radio Signalling links (LPDLRs). It consists of two
fields:
"secondLevelUpperThreshold"
if the signalling traffic overcomes this threshold the BTSE
starts periodic sending LAPD overload message.
"secondLevelLowerThreshold"
if the signalling traffic falls below this threshold the BTSE
stops periodic sending LAPD overload message.
upperThreshold 10 - 100
lowerThreshold 10 - 100
90
80
0 - 15


A30808-X3247-M230-6-7619

2057
CML:BSC s
Id:0900d805800d6c0e
Contained in the following commands:
CREATE SS7L, GET SS7L
SLLPRM
signallingLayerListPrimary
This parameter defines the list of TRX layers assigned to services requiring only Signal-
ling Channel in a single band standard cell, or in the complete/far area of a dual area
cell (extended, concentric single/dual band), or in the BCCH band of a dual band
standard cell. The TRX layers are specified in the list in a decreasing priority order.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
SMLCPERTFLAG
sMLCPeriocTestFlag
This attribute represents the flag to enable the periodic test towards SMLC (SLT proce-
dure).
1 to 12 items of
ly_00
ly_01
ly_02
ly_03
ly_04
ly_05
ly_06
ly_07
ly_08
ly_09
ly_10
ly_11
<NULL>
NULL


2058 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
SMLCSPC
sMLCSignallingPointCode
This attribute identifies the Signalling Point Code (SPC) of the SMLC (Serving Mobile
Location Center).
It consists of three fields: networkClusterMember, networkCluster and networkIdentifier;
the first two fields are mandatory while the third field is optional.
Validity Range
Default Value
NULL
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
SMSCBUSE
smsCBUsed
This attribute indicates if the Short Message Service Cell Broadcast is enabled or dis-
abled.
TRUE
FALSE
TRUE
networkCluster-
Member
0 - 255 0..255 for CCITT
1..255 for ANSI
networkCluster 0 - 255 0..63 for CCITT
0..255 for ANSI
networkIdentifier 1 - 254 1..254 for ANSI
NO_CONFIG for CCITT
<NULL>


A30808-X3247-M230-6-7619

2059
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
SMSINFO
smsInfo
This attribute represents the weight for the predefined PFI SMS. This parameter
consists of the two fields: pfiWeight and smsSDUsize.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
SMSPFITODIFFSERV
smsPFIToDiffserv
This attribute represents the mapping between predefined PFI SMS parameter and
DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SNSADDRET
subnetworksAddRetries
TRUE
FALSE
FALSE
pfiWeight 1 - 32
smsSDUSize 160 - 1560
pfiWeight 1
smsSDUSize 160
0 - 63
0


2060 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
This attribute defines the number of retries for SNS-Add procedure before failure notifi-
cation (IP).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SNSCHWEIRET
sNSChangeWeigthRetries
This attribute defines the number of retries for SNS-ChangeWeight procedure before
failure notification (IP).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SNSCONFRET
subnetworksConfigRetries
This attribute defines the number of retries for SNS-Config procedure before failure noti-
fication (IP).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SNSDELRET
subnetworksDeleteRetries
0 - 16
<NULL>
0 - 16
<NULL>
0 - 16
<NULL>


A30808-X3247-M230-6-7619

2061
CML:BSC s
Id:0900d805800d6c0e
This attribute defines the number of retries for SNS-Delete procedure before failure noti-
fication (IP).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SNSSIZERET
subnetworksSizeRetries
This attribute defines the number of retries for SNS-Size procedure before failure notifi-
cation (IP).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SOURCE
source
This attribute identifies the source from which the MPCC executable file is loaded.
Validity Range
Default Value
None.
Contained in the following commands:
LOADMPCC SOFTWARE-MANAGEMENT
SPEED145
speedSupported_14_5
This attribute controls the 14.4 kbit/s data service activation.
0 - 16
<NULL>
0 - 16
<NULL>
LMT
SYS_FALLBACK


2062 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
SPENLAW
speechEncodingLaw
This attribute specifies the type of G.711 speech encoding law used.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
SPFITODIFFSERV
signallingPFIToDiffserv
This attribute represents the mapping between predefined PFI signalling parameter and
DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
SPFIWEI
signallingPFIWeigh
This attribute represents the weight for the predefined PFI signalling.
TRUE
FALSE
FALSE
A_LAW
U_LAW
A_LAW
0 - 63
0


A30808-X3247-M230-6-7619

2063
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
SRCDIR
sourceDir
Validity Range
In commands FILECOM FILEHANDLER, FILEDECOM FILEHANDLER:
In commands DNLIDFD REMINV:
In commands UPLFILE SOFTWARE-MANAGEMENT:
Default Value
None.
Contained in the following commands:
DNLIDFD REMINV, FILECOM FILEHANDLER, FILEDECOM FILEHANDLER,
UPLFILE SOFTWARE-MANAGEMENT
SRCFILE
sourceFile
This attribute defines the name of the compressed file.
1 - 32
16
This parameter specifies the name of the directory on the BSC disk
or LMT disk which the file has to be transferred from.
The user can use the "Browse Dir" button to select the directory on
the LMT disk; this button is not available for the FILEHANDLER
object commands and for the UPLFILE command.
For the DNLIDFD command, this parameter specifies the source
directory where the BSC_NRIU file is stored.
1..45 characters string
0..80 characters string
1..80 characters string


2064 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
None.
Contained in the following commands:
FILEDECOM FILEHANDLER
SRCPATH
relatedFiles
This parameter represents the source path of the files which are copied. It consists of
two fields divided by \ symbol: the first is the path while the second field represents the
file name; the user can use the Browse File Path button to select the directory on the
LMT file disk.
Validity Range
Default Value
None.
Contained in the following commands:
LOADMPCC SOFTWARE-MANAGEMENT, CREATE RSUDB, CREATE RSUEXE,
CREATE RSUPCH, CREATE RSUSWLH
SRCPATHNAME
sourcePathName
This parameter represents the source path of the files which are to be copied or moved.
Validity Range
Default Value
None.
Contained in the following commands:
COPY FILEHANDLER, MOVE FILEHANDLER
SS7MTPTYP
ss7MtpType
This attribute indicates the type of link at the A interface (ANSI or CCITT).
1..13 characters string
1..80 character string\1..13 character string for the LOADMPCC command;
..81 character string\1..13 for all the other commands
1..59 characters string


A30808-X3247-M230-6-7619

2065
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC
START
startDate
This parameter represents the starting day of the collecting activity for the scanner or
SCA instance; it consists of three fields: day, month and year.
Validity Range
Default Value
Contained in the following commands:
CREATE CTRSCHED, CREATE HDCTR, CREATE RFLOOP, CREATE SCA,
CREATE SCANBSC, CREATE SCANBTS, CREATE SCANBTSE, CREATE SCAN-
BTSIHO, CREATE SCANBTSM, CREATE SCANBTSOHOI, CREATE SCANBTSO-
HON, CREATE SCANBTSOHOS, CREATE SCANCHAN, CREATE SCANCTRX,
CCITT
ANSI
CCITT
day 1 - 31
month Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
year 1992 - 2099
day 1
month Jan
year 1995


2066 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
CREATE SCANFBTSM, CREATE SCANGPRS, CREATE SCANSS7L, CREATE
SCANTRX, GET CTRSCHED, GET HDCTR, GET RFLOOP, GET SCA, GET
SCANBSC, GET SCANBTS, GET SCANBTSE, GET SCANBTSIHO, GET SCAN-
BTSM, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS, GET
SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET
SCANSS7L, GET SCANTRX, SET CTRSCHED, SET HDCTR, SET RFLOOP, SET
SCA, SET SCANBSC, SET SCANBTS, SET SCANBTSE, SET SCANBTSIHO, SET
SCANBTSM, SET SCANBTSOHOI, SET SCANBTSOHON, SET SCANBTSOHOS,
SET SCANCHAN, SET SCANCTRX, SET SCANFBTSM, SET SCANGPRS, SET
SCANSS7L, SET SCANTRX
STGTTLLIINF
storageTimeTLLIInfo
This attribute indicates the time (in seconds) for which the BSC stores the information
about TLLI (last used coding scheme and BLER) after the end of each TBF for that TLLI.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
STOP
stopDate
This parameter represents the last day of the collecting activity for the scanner or SCA
instance; it consists of three fields: day, month and year.
10 - 90
<NULL>
10


A30808-X3247-M230-6-7619

2067
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
Contained in the following commands:
CREATE CTRSCHED, CREATE HDCTR, CREATE RFLOOP, CREATE SCA,
CREATE SCANBSC, CREATE SCANBTS, CREATE SCANBTSE, CREATE SCAN-
BTSIHO, CREATE SCANBTSM, CREATE SCANBTSOHOI, CREATE SCANBTSO-
HON, CREATE SCANBTSOHOS, CREATE SCANCHAN, CREATE SCANCTRX,
CREATE SCANFBTSM, CREATE SCANGPRS, CREATE SCANSS7L, CREATE
SCANTRX, GET CTRSCHED, GET HDCTR, GET RFLOOP, GET SCA, GET
SCANBSC, GET SCANBTS, GET SCANBTSE, GET SCANBTSIHO, GET SCAN-
BTSM, GET SCANBTSOHOI, GET SCANBTSOHON, GET SCANBTSOHOS, GET
SCANCHAN, GET SCANCTRX, GET SCANFBTSM, GET SCANGPRS, GET
SCANSS7L, GET SCANTRX, SET CTRSCHED, SET HDCTR, SET RFLOOP, SET
SCA, SET SCANBSC, SET SCANBTS, SET SCANBTSE, SET SCANBTSIHO, SET
SCANBTSM, SET SCANBTSOHOI, SET SCANBTSOHON, SET SCANBTSOHOS,
SET SCANCHAN, SET SCANCTRX, SET SCANFBTSM, SET SCANGPRS, SET
SCANSS7L, SET SCANTRX
STPIPEP
startupRemoteIPEndpoint
This attribute indicates the Startup remote IP endpoint.
day 1 - 31
month Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
year 1992 - 2099
day 31
month Dec
year 2099


2068 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
STREAMSUP
streamingSupport
This attribute allows the enabled/disabled of the real time streaming support.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
STREAMTODIFFSERV
streamingToDiffserv
This attribute represents the mapping between streaming class and DSCP coding.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
STREAMWEI
streamingWeight
This attribute represents the weight for streaming class.
ipAddress 7..15 characters
string
udpPort 1024 - 65535
<NULL>
ENABLED
DISABLED
DISABLED
0 - 63
0


A30808-X3247-M230-6-7619

2069
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
SUBBAND
subordinateBand
This attribute indicates the frequency band to which the CFHSY is applicable.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CFHSY, GET CFHSY, SET CFHSY
SUBNETMASK
subnetMask
This attribute is the NetMask that is assigned to both the MPCC port copies. The value
must be assigned according to the local LAN configuration. The convention used for this
value is the dotted decimal format (e.g. "255.255.255.0").
Validity Range
Default Value
None.
Contained in the following commands:
CREATE IPLI, GET IPLI, SET IPLI
SUBNETMASK<N>
subNetMask<n>
1 - 32
32
gSM850
pCS1900
dCS1800
bB900
eB900
7..15 characters string


2070 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
This attribute is the NetMask for IP address associated to all PCU port 0. The value must
be assigned according to the local LAN configuration. The convention used for this value
is the dotted decimal format (e.g. "255.255.255.0").
Note: The attributes ROUIPADD0, ROUIPADD1, SUBNETMASK0, SUBNETMASK1
are necessary only if SGSN is connected to BSC via router. If the router is not present,
these attributes must be set to <NULL>.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
SUPPER
supervisionPeriod
The "Supervision Period" defines the duration between two successive threshold com-
parisons on the observed QoS Indicator.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBSC, CREATE QSMONBTS, CREATE QSMONGPRS, GET
QSMONBSC, GET QSMONBTS, GET QSMONGPRS, SET QSMONBSC, SET
QSMONBTS, SET QSMONGPRS
SYNCHRO
synchro
This attribute sets scripts execution mode: in synchronous scripts, each command is not
executed until the previous one has been replied by the Network Element; in asynchro-
nous scripts, all commands are sent at once.
7..15 characters string
<NULL>
NULL
minutes_5
minutes_10
minutes_15
minutes_5


A30808-X3247-M230-6-7619

2071
CML:BSC s
Id:0900d805800d6c0e
Validity Range
Default Value
None.
Contained in the following commands:
EXEC LMT-INTERNAL, SET LMT-INTERNAL
SYSID
systemIndicator
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
SYSPACKSYSSUP
sysInfoPacketSysInfoSupport
The value of this parameter indicates if the PACKET PSI STATUS and PACKET SI
STATUS messages are supported or not in the BSC.
NO
YES
It indicates the frequency band used by the
cell.
BB900 (GSM Standard Band)
DCS1800
EXT900 (GSM Mixed Band)
PCS1900
GSMR (Railway Band)
GSMDCS
GSM850
GSM850PCS
GSM850DCS


2072 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6c0e
s
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

2073
CML:BSC t
Id:0900d805800d6bfc
t
T1
timerT1
This parameter identifies the Timer T1. For PCU, this timer defines the waiting time for
BVCI block/unblock procedure; after a BVCI block/unblock message sent, the PCU
waits T1 seconds for acknowledge.
In commands related to PCPCU, values are expressed in seconds.
In commands related to X25A, values are expressed in 100 ms unit.
Validity Range
In commands CREATE CPCU, GET CPCU, SET CPCU:
In commands CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET
X25D:
Default Value
In moc(s) X25D, X25A:
In moc(s) CPCU:
Contained in the following commands:
CREATE CPCU, CREATE X25A, CREATE X25D, GET CPCU, GET X25A, GET
X25D, SET CPCU, SET X25A, SET X25D
T10UNIT
t10Unit
This read-only parameter defines the measurement unit for the M3T10 timer.
Validity Range
Default Value
None.
2 - 29 (100 ms unit)
1 - 3000 (100 ms unit)
80
10
MS100 msec unit
HLFSEC
SEC5


2074 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Contained in the following commands:
GET OPC
T12UNIT
t12Unit
This read-only parameter defines the measurement unit for the M3T12 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T13UNIT
t13Unit
This read-only parameter defines the measurement unit for the M3T13 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T14UNIT
t14Unit
This read-only parameter defines the measurement unit for the M3T14 timer.
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5


A30808-X3247-M230-6-7619

2075
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T17UNIT
t17Unit
This read-only parameter defines the measurement unit for the M3T17 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T19UNIT
t19Unit
This read-only parameter defines the measurement unit for the M3T19 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T1TMUNIT
t1tmUnit
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5


2076 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
This read-only parameter defines the measurement unit for the M3T1TM timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T1UNIT
t1Unit
This read-only parameter defines the measurement unit for the M2T1 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T1UNIT1
t1Unit1
This read-only parameter defines the measurement unit for the M3T1 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5


A30808-X3247-M230-6-7619

2077
CML:BSC t
Id:0900d805800d6bfc
T2
t2
This timer defines the waiting time for BVCI reset procedure. After a BVCI reset
message sent, the PCU waits T2 seconds for acknowledge.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T20
restartRequestTimeout
Restart request time-out.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
T200
t200
This attribute contains values for the LapDm Timer 200, to be used on the different
control channels.
2 - 119 seconds
10
0 - 3000 (100 msec step size)
1800


2078 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
T21
callRequestTimeout
Call request time-out.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
T22
resetRequestTimeout
Reset request time-out.
sdcchSAPIO 0 - 255 (5 msec step size)
facchTCHF 0 - 255 (5 msec step size)
facchTCHH 0 - 255 (5 msec step size)
sacchTCHSAPIO 0 - 255 (10 msec step size)
sacchSDCCH 0 - 255 (10 msec step size)
sdcchSAPI3 0 - 255 (5 msec step size)
sacchTCHSAPI3 0 - 255 (10 msec step size)
sdcchSAPIO 29
facchTCHF 31
facchTCHH 38
sacchTCHSAPIO 90
sacchSDCCH 70
sdcchSAPI3 29
sacchTCHSAPI3 168
0 - 3000 (100 msec step size)
2000


A30808-X3247-M230-6-7619

2079
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
T22OR20UNIT
t22or20Unit
This read-only parameter defines the measurement unit for the M3T22OR20 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T23
clearRequestTimeout
Clear request time-out.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
T23OR21UNIT
t23or21Unit
This read-only parameter defines the measurement unit for the M3T23OR21 timer.
0 - 3000 (100 msec unit)
1800
MS100 msec unit
HLFSEC
SEC5
0 - 3000 (100 msec unit)
1800


2080 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T26
interruptRequestTimeout
Interrupt request time-out.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
T28
registrationRequestTimeout
Registration request time-out.
Validity Range
Default Value
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
T2TMUNIT
t2tmUnit
This read-only parameter defines the measurement unit for the M3T2TM timer.
MS100 msec unit
HLFSEC
SEC5
0 - 3000 (100 msec unit)
1800
0 - 3000 (100 msec unit)
0


A30808-X3247-M230-6-7619

2081
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T2UNIT
t2Unit
This read-only parameter defines the measurement unit for the M2T2 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T2UNIT1
t2Unit1
This read-only parameter defines the measurement unit for the M3T1 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T3
timer3
This timer defines the waiting time for a response from the SGSN after sending a
SUSPEND PDU. Default value 50 corresponds to 5 seconds.
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit


2082 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T3101
btsTimer3101
This timer (btsTimer3101) is started when a channel is allocated with an IMMEDIATE
ASSIGNMENT message and stopped when MS has correctly seized the channels.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
T3105
btsTimer3105
The Timer T3105 is used for the repetition of PHYSICAL INFORMATION message
during the handover procedure between non synchronized cells. The maximum number
of repetitions is determined by the parameter NY1 (see command SET:BTS). If this
number is reached and T3105 expires again, the BTS sends a CONNECTION FAILURE
INDICATION message with cause 'handover access failure' to the BSC which releases
the new allocated channels and stops the context related to the handover.
The combination of the values NY1=30 and T3105=MS10-10 has turned out to improve
the 'handover speech gap' in case of BSCcontrolled intercell handover.
T3105 is restricted to a maximum time of 120ms.
This means that all settings greater than T3105=MS10-12 are treated as if the value
T3105=MS10-12 was entered.
0.1 - 10.0 step 1 (0.1 sec :10 sec step= 0.1sec)
5.0
tunit MS100
HLFSEC
SEC5
tvalue 0 - 255
tunit HLFSEC
tvalue 6


A30808-X3247-M230-6-7619

2083
CML:BSC t
Id:0900d805800d6bfc
After the first PHYS INFO retransmission the BTS sets T3105 to the fixed value 50ms
and thus ignores the database setting of T3105, i.e. the second and following retrans-
missions are all scheduled with T3105=50ms. As still the overall time the BTS spends
to transmit the PHYS INFO and to receive the SABM should be greater or equal 2
seconds, the rule NY1*T3105 >= 2 sec. must be adapted as follows:
T3105 + NY1*50ms >= 2 sec.
Thus (e.g. with a setting of T3105=MS10-10) the value NY1 should be set at least to 40.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
T3107
btsTimer3107
This read-only parameter defines
It consists of two fields: tunit and tvalue.
Validity Range
Default Value
None.
Contained in the following commands:
GET BTS
tunit MS10
tvalue 1 - 254
tunit MS10
tvalue 10
tunit MS100
HLFSEC
SEC5
tvalue 0 - 255


2084 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
T3109
btsTimer3109
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
T3111
btsTimer3111
Timer used to delay the channel deactivation after disconnection of the main signalling
link. Its purpose is to let a sufficient time for possible repetition of the disconnection.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
Note It's recommended to set the related values of timers T3109 and
TSYNC respecting the following rule:
T3109+2sec<TSYNC
If default values are set not respecting the above rule, please change
the values with SET command.
Timer started when a lower layer failure is detected by the network
to permit a correct release of the channel in case of loss
of communication.
tunit MS100
HLFSEC
SEC5
tvalue 0 - 255
tunit HLFSEC
tvalue 8
tunit MS100
HLFSEC
SEC5
tvalue 0 - 255
tunit HLFSEC
tvalue 1


A30808-X3247-M230-6-7619

2085
CML:BSC t
Id:0900d805800d6bfc
T3122
waitIndication
Wait indication: this timer sets the MS (Mobile Station) waiting time before attempting
another channel request after reception of the IMMEDIATE ASSIGNMENT REJECT
message.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
T3141
t3141
This timer is started when a tbf is assigned with an immediate
assignment during a packet access procedure; it is stopped when the ms has correctly
seized the tbf.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T3168
t3168
This value plus one must be multiplied by 500 msec. to obtain the real value used in PSI
messages.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
0 - 255 s
5
1 - 30 s
5
0 - 7
2


2086 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
T3169
t3169
This timer defines the waiting time for reuse TFI and USF after the thresholds N3101
and N3103 are reached.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T3172
t3172
This timer is set after the reception of a PACKET ACCESS REJECT message and
defines the MS waiting time before attempting another access to the cell. The timer is
stopped if the MS receives a PACKET UPLINK ASSIGNMENT message.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T3191
t3191
This timer defines the waiting time for reuse TFI and USF after having sent the last RLC
block.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
1 - 30 s
5
0 - 255 s
5
1 - 30 s
5


A30808-X3247-M230-6-7619

2087
CML:BSC t
Id:0900d805800d6bfc
T3192
t3192
This parameter is used in the PSI (Packet System Information) messages. If it is set at
the 3 value (corresponding to 0 ms), the timer is not started.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
T3193
t3193
This time-out timer must be set at a greater value than the timer T3192.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T3195
t3195
PSI Count High Rate.
0 - 7 The following list shows the correspondence between
selected values and real values:
0500 ms
11000 ms
21500 ms
30 ms
480 ms
5120 ms
6160 ms
7200 ms
0
1 - 42 (100 ms unit)
4


2088 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T3197
t3197
Timer controlling the maximum duration by which the BSC will delay the release of the
RR connection.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
T3212
btsTimer3212
It specifies the interval for the MS periodic location updates. The value zero indicates
the MS should not perform any periodic location updates.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
T391
t391
This timer represents the link integrity verification repetition.
( I ) The value of the timer T391 set on the BSC side must be lower than the value of the
timer T392 set either on the SGSN or the network side of the Frame Relay link.
0 - 255 s
5
3 - 5 (500 msec unit)
4
0 - 255 in decihours (0.. 25.5 hours)
10


A30808-X3247-M230-6-7619

2089
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
T3UNIT
t3Unit
This read-only parameter defines the measurement unit for the M2T3 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T3UNIT1
t3Unit1
This read-only parameter defines the measurement unit for the M3T1 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T4
timer4
This timer defines the waiting time for a response from the SGSN after sending
RESUME PDU.
1 - 60
10
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit


2090 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
In commands CREATE CPCU, GET CPCU, SET CPCU:
In commands CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET
X25D:
Default Value
In moc(s) CPCU:
In moc(s) X25D, X25A:
Contained in the following commands:
CREATE CPCU, CREATE X25A, CREATE X25D, GET CPCU, GET X25A, GET
X25D, SET CPCU, SET X25A, SET X25D
T4EUNIT
t4EUnit
This read-only parameter defines the measurement unit for the M2T4E timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T4NUNIT
t4NUnit
This read-only parameter defines the measurement unit for the M2T4N timer.
0.1 - 10.0 (t4 >= t1*2 value racommended)
0 - 9000 (t4 >= t1*2 value racommended)
1.0
200
MS100 msec unit
HLFSEC
SEC5


A30808-X3247-M230-6-7619

2091
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T4UNIT
t4Unit
This read-only parameter defines the measurement unit for the M3T4 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T5
T5
This timer is started from BSC when RA-Capability-Update is stransmitted to SGSN and
stops it when RA-Capability-Update-Ack is received.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
T5UNIT
t5Unit
This read-only parameter defines the measurement unit for the M2T5 timer.
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
HLFSEC
SEC5
2 - 29
10


2092 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T5UNIT1
t1Unit1
This read-only parameter defines the measurement unit for the M3T1 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T6UNIT
t6Unit
This read-only parameter defines the measurement unit for the M2T6 timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
T7UNIT
t7Unit
This read-only parameter defines the measurement unit for the M2T7 timer.
MS100 msec unit
HLFSEC
SEC5
MS100 msec unit
MS100 msec unit
HLFSEC
SEC5


A30808-X3247-M230-6-7619

2093
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TAADJ
taAdjust
This attribute takes into account the propagation delay created on the BTS internal
signal path in both directions.
Validity Range
Default Value
0 if the BTS SW = 7.0
NULL otherwise
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TARGDIR
targetDirectory
For the FILECOM software command, this parameter defines the directory name of the
BSC disk of the compressed file.
For the FILEDECOM software command, it defines the directory name where the
decompressed files must be placed.
Validity Range
Default Value
None.
Contained in the following commands:
FILECOM FILEHANDLER, FILEDECOM FILEHANDLER
MS100 msec unit
HLFSEC
SEC5
0 - 100 (100 ns step size)
<NULL>
1..45 characters string


2094 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TARGF
targetFile
This attribute defines the name of target compressed file.
Validity Range
Default Value
None.
Contained in the following commands:
FILECOM FILEHANDLER
TAVGT
tAverageTime
This attribute indicates the signal strength filter period for power control in packet
transfer mode.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TAVGW
tAverageWeight
This attribute indicates the signal strength filter period for power control in packet idle
mode.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TBFDROR
tBFDropRate
1..13 characters string
0 - 25
5
0 - 25
15


A30808-X3247-M230-6-7619

2095
CML:BSC t
Id:0900d805800d6bfc
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONGPRS, GET QSMONGPRS, SET QSMONGPRS
TBFLOSR
tBFLossRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONGPRS, GET QSMONGPRS, SET QSMONGPRS
TBFREAFAIR
tBFReasignmentFailureRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONGPRS, GET QSMONGPRS, SET QSMONGPRS
Pathname
<NULL>
NULL
Pathname
<NULL>
NULL
Pathname
<NULL>
NULL


2096 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TBNCU
timerBackNcUmts
This timer is started relatively to a MS/UE, when this mobile has reselected a
GSM/GPRS cell. Until its expiry, NC GSM/GPRS to UMTS cell reselection shall be inhib-
ited for this MS/UE.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TCBCSI
timerForCBCServiceInterruption
This timer defines the time a BTS can remain out of service without BSC clearing of all
messages concerning that particular cell.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TCCCHLDI
thresholdCcchLoadIndication
This value is a threshold used by the BTS to inform the BSC about the load of CCCH. It
is used in PCH and RACH load measurements. For the PCH it determines the percent-
age of possible paging requests stored in the BTS before CCCH load indication is sent
to BSC. For the RACH the parameter determines the percentage of RACH slots related
to rachLoadAveragingSlots that have to be considered busy before a CCCH load indi-
cation is sent to BSC.
0 - 100 s
5
0 - 1440 minutes
Value 0 means "No message clearing from BSC".
0


A30808-X3247-M230-6-7619

2097
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TCHDROR
tCHDropRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
TCHLOSR
tCHLossRate
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBTS, GET QSMONBTS, SET QSMONBTS
TCONG
timeCongestion
0 - 100 (1% step size)
100
Pathname
<NULL>
NULL
Pathname
<NULL>
NULL


2098 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
It specifies the observation window for the congestion detection. If the frames coming
from SGSN containing congestion are equal or greater than the frame indicating no con-
gestion, the congestion state is notified to upper layers.
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
TCONN
tconn
Wait for connection confirmation message.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TCONNUNIT
tConnUnit
This read-only parameter defines the measurement unit for the TCONN timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TCONOFF
timeCongestionOff
1 - 30 s
10
0 - 255 0..255 unit of 5 sec for CCITT
1.. 72 unit of 5 sec for ANSI
3
MS100 msec unit
HLFSEC
SEC5


A30808-X3247-M230-6-7619

2099
CML:BSC t
Id:0900d805800d6bfc
This attribute specifies the window for congestion abatement. After a congestion notifi-
cation, no other notifications are foreseen for the time configured in this parameter. This
timer is needed to provide a
hysteresis time in order to ensure that the traffic reduction at mobile station can be effec-
tive.
Validity Range
Default Value
Contained in the following commands:
CREATE FRL, GET FRL, SET FRL
TDDARFCN
tddArfcn
This parameter defines the frequency of the TDD cell: the rule is tddArfcn = 5 *
freq_uplink (or freq_downlink).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTTDD, GET TGTTDD, SET TGTTDD
TDDCPAR
tddCellParameter
This parameter defines the Cell Parameter.
In case of BNDWIDTDD = MCPS384:
- SYNC1 means Sync Case 1
- SYNC2 means Sync Case 2
In case of BNDWIDTDD = MCPS128:
- SYNC1 means TSTD not applied
- SYNC2 means TSTD applied
0 - 30 seconds (with step 1), plus 0 value;
0 means no hysteesis time used
Values from 0 to 9 are not allowed
20
9262 - 10113


2100 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTTDD, GET TGTTDD, SET TGTTDD
TDDDIV
tddDiversity
This parameter indicates if diversity is used or not in TDD cell.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTTDD, GET TGTTDD, SET TGTTDD
TDDGQO
tddGprsQOffset
This parameter relates multiRAT mobiles; it indicates an offset which is applied for
carrier level of the TDD serving cell.
0 - 127
NO_DIVERSITY means that SCTD is not applied for this cell
DIVERSITY means that SCTD is applied for this cell


A30808-X3247-M230-6-7619

2101
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TDDMURREP
tddMultiratReporting
This parameter indicates the number of TDD UTRAN cells to include in the measure-
ment report.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TDDQO
tddQOffset
ALWAYS
MDB28
MDB24
MDB20
MDB16
MDB12
MDB08
MDB04
DB00
DB04
DB08
DB12
DB16
DB20
DB24
DB28
DB00
0 - 3
0


2102 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
This parameter relates multiRAT mobiles; it indicates an offset which is applied for
carrier level of the TDD serving cell.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TDDREPO
tddReportOffset
This parameter defines offset to be applied to reported cells.
ALWAYS
MDB28
MDB24
MDB20
MDB16
MDB12
MDB08
MDB04
DB00
DB04
DB08
DB12
DB16
DB20
DB24
DB28
DB00


A30808-X3247-M230-6-7619

2103
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TDDREPTH
tddReportThreshold
This parameter defines threshold which UTRAN cell has to exceed in order to be
reported in Enhanced Measurement Report.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TDDSYNCCAS
tddSyncCase
This parameter defines the Cell Parameter.
db_00
db_06
db_12
db_18
db_24
db_30
db_36
db_42
db_00
rxlev_00
rxlev_06
rxlev_12
rxlev_18
rxlev_24
rxlev_30
rxlev_36
never
rxlev_00


2104 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
In case of BNDWIDTDD = MCPS384:
- SYNC1 means Sync Case 1
- SYNC2 means Sync Case 2
In case of BNDWIDTDD = MCPS128:
- SYNC1 means TSTD not applied
- SYNC2 means TSTD applied
Validity Range
Default Value
None.
Contained in the following commands:
CREATE TGTTDD, GET TGTTDD, SET TGTTDD
TDPCPRCSLD
tdpcProcessorLoad
This parameter is specific for each QoS Indicator allows the operator to specify the QoS
Threshold Set to be used.
Validity Range
Default Value
Contained in the following commands:
CREATE QSMONBSC, GET QSMONBSC, SET QSMONBSC
TDTMWIND
timerDTMWaitIndicator
This timer sets value to be included in DTM Reject message; indicates waiting time,
before MS may again send DTM-Request.
SYNC1
SYNC2
Pathname
<NULL>
NULL


A30808-X3247-M230-6-7619

2105
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TEI
tei
This parameter defines the TEI (Terminal Endpoint Identifier) number.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE BTSM, CREATE TRAU, GET BTSM, GET TRAU, GET TRX
TEMPCH
timerEmptyChannel
This specifies the time for releasing PDCHs if no activities are done. This timer should
prevent a faster PDCH channel allocation/release that can increase TDPC load.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TEMPOFF
temporaryOffset
This attribute applies a negative offset to C2 for the duration of
penaltyTime.
0 - 255 sec
5
0 - 63
1 - 254 s
30


2106 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
1
Contained in the following commands:
CREATE BTS, CREATE TGTBTS, GET BTS, GET TGTBTS, SET BTS, SET
TGTBTS
TEMPPDT
timerEmptyPDT
This attribute defines the time in units of seconds for releasing a PDT with Subframe
Counter > 0 if no TBF is actually using it to transfer payload.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TEXT
text
This attribute defines the double quoted string BMML command or failed TEST
command.
Validity Range
Default Value
None.
Contained in the following commands:
ECHO LMT-INTERNAL
TEXTULTBF
timeExtendedUplinkTBF
This attribute is used to delay the release of an UL Temporary Block Flow (TBF) in
Extended UL TBF mode.
0 - 7 (0..60 dB, unit of 10dB) 7 means infinity
<NULL>
1 - 30
15
1..256 characters string character double quoted string


A30808-X3247-M230-6-7619

2107
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TF
tF
When SGSN receives PFC FLOW CONTROL parameters, SGSN starts TF Timer.
When TF expires SGSN may use SGSN Bmax and R generated and not more last Bmax
and R sent by BSC. TF is restarted each time a PFC FLOW CONTROL parameters are
received.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TF1
tf1
This timer defines the time for capacity reporting period used in flow control algorithm.
It corresponds to the C timer reported in the GSM 08.18 recommendation.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TFAILNCU
timerFailNcUmtsCell
This parameter defines the timer started from BSC when it has received a PACKET
CELL CHANGE FAILURE message containing an UMTS cell description from a MS/UE.
0 - 49 (100 msec step size)
15
5 - 6000
2 - 9 s extremes excluded
2


2108 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Until expiry of this timer, this UMTS neighbour cell is excluded from the UMTS Target
Cell List.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TGRANT
timerGrant
This timer is used for the repetition of the VGCS_UPLINK_GRANT message during an
uplink access procedure.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TGTCELL
targetCell
This attribute indicates the adjacent cell, namely the BTS object if it belongs to the same
BSC (TGTCELL = BTSM:#/BTS:#) or the TGTBTS if it belongs to another BSC
(TGTCELL = TGTBTS:#), or the TGTFDD if it is a UMTS one.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
TGUARD
tGuard
0 - 100 s
12
1 - 254
4
Pathname (i.e. OBJ1:2/OBJ2:1/OBJ3:5)


A30808-X3247-M230-6-7619

2109
CML:BSC t
Id:0900d805800d6bfc
Wait to resume normal procedures for the temporary connection sections, during the
restart procedure.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TGUARDTCHSD
timerGuardTchsd
This timer defines the time to wait before returning TCHSD channels to TCHSDPOOL
when the sub-channel to be released is coming from the SDCCHBACKUPPOOL and is
the last busy sub-channel in the TCHSD.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TGUARDUNIT
tGuardUnit
This read-only parameter defines the measurement unit for the TGUARD timer.
0 - 255 units of 5 seconds
36
SEC00
SEC10
SEC11
SEC12
SEC13
SEC14
SEC15
SEC10


2110 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TH
tH
When SGSN receives MS FLOW CONTROL parameters, SGSN starts TH Timer. When
TH expires SGSN may use SGSN Bmax and R generated and not more last Bmax and
R sent by BSC. TH is restarted each time a MS FLOW CONTROL parameters are
received.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
THLEVFULHO
thresholdLevFastULHo
This parameter defines the receive signal strength threshold for an inter-cell fast uplink
HO decision.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
THORQST
timerHoRequest
MS100 msec unit
HLFSEC
SEC5
5 - 6000
0 - 63
6


A30808-X3247-M230-6-7619

2111
CML:BSC t
Id:0900d805800d6bfc
This attribute defines the minimum interval between handover condition indication
messages related to the same connection. However in case an handover condition indi-
cation was sent with an empty target cell list the next may be sent as soon as a target
cell is available from radio condition criteria.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
THPROXT
thresholdProximityTimer
This parameter implements 3 thresholds for TH-proximity evaluation. The first threshold
range is from 10 msec. to 1000 msec., the second threshold range is from 1 sec. to 100
sec., the third threshold range is from 100 sec. to 1000 sec.
This parameter was introduced for an older SMG version and is no longer used starting
from Release BR6.0.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
THR
threshold
This attribute indicates the time (in seconds) of persistency of the detected alarm before
it is notified through a FER.
0 - 31 (2 SACCH multiframes step size)
5
THPROXT1 10 - 999 (ms)
THPROXT2 1 - 100 (s)
THPROXT3 101 - 1000 (s)
THPROXT1 500
THPROXT2 50
THPROXT3 550


2112 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
Contained in the following commands:
CREATE ENVA, GET ENVA, SET ENVA
THRS<N>
thresholdSet<n>
This attribute defines different parameters for the threshold supervision for different
traffic situations. Each threshold set is a structure with the following elements:
- Number of Samples
- Threshold Major High
- Threshold Major Low
- Threshold Minor High
- Threshold Minor Low
- Number of Periods
Validity Range
In commands CREATE QSTHRS, GET QSTHRS, SET QSTHRS:
In commands CREATE QSTHRS, GET QSTHRS, SET QSTHRS, CREATE QSTHRS,
GET QSTHRS, SET QSTHRS:
Default Value
In moc(s) QSTHRS:
2 - 65534
2
numberOfSamples 1 - 65533
thresholdMajorHigh 0 - 100 (1% step size)
thresholdMajorLow 0 - 100 (1% step size)
thresholdMinorHigh 0 - 100 (1% step size)
thresholdMinorLow 0 - 100 (1% step size)
numberOfPeriods 1 - 12
numberOfSamples 1 - 65533
thresholdMajorHigh 0 - 100 (1% step size)
thresholdMajorLow 0 - 100 (1% step size)
thresholdMinorHigh 0 - 100 (1% step size)
thresholdMinorLow 0 - 100 (1% step size)
numberOfPeriods 1 - 12
<NULL>


A30808-X3247-M230-6-7619

2113
CML:BSC t
Id:0900d805800d6bfc
None.
In moc(s) QSTHRS, QSTHRS:
Contained in the following commands:
CREATE QSTHRS, GET QSTHRS, SET QSTHRS
THSULBAL
thresholdSwitchULBalanced
This attribute represents the threshold to switch to UL balanced method.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TIAR
tiar
Wait for reception of a message on a connection section. Inactivity test receive timer.
The SCCP connection will be released if there is no inactivity test message received
within the TIAR interval.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TIARUNIT
tiarUnit
This read-only parameter defines the measurement unit for the TIAR timer.
NULL
0 - 2000 (unit : octects)
587
0 - 255 0.. 255 units of 5 sec for CCITT
132..255 units of 5 sec for ANSI
180


2114 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TIAS
tias
Delay in sending a message on a connection section. Inactivity test sent timer. The inac-
tivity test message is sent every TIAS interval.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TIASUNIT
tiasUnit
This read-only parameter defines the measurement unit for the TIAS timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
MS100 msec unit
HLFSEC
SEC5
0 - 255 0.. 255 units of 5 sec for CCITT
60..120 units of 5 sec for ANSI
96
MS100 msec unit
HLFSEC
SEC5


A30808-X3247-M230-6-7619

2115
CML:BSC t
Id:0900d805800d6bfc
TIMADVR
timingAdvanceRanges
This parameter requires 7 input values which define the 8 ranges of
Timing Advance TAred (Input_value1, Input_value2, .. ,
Input_value7);
the input_values are related to the Timing Advance (TA) and Timing
Offset (TO) of the measurement report.
TA = TO_measurement_report + TA_measurement_report
The TA value is then related to steps of 550 meters. The allowed
input values for TA are 0 to 550, defined by means of "range-
Bound<n>" fields (<n>=1..7).
The correspondence between the Input_values, TA_RED and TA is
the following:
TA_RED_Range0: TA<= Inputvalue1
TA_RED_Range1:Input_value1 <TA<= Inputvalue2
TA_RED_Range2:Input_value2 <TA<= Inputvalue3
TA_RED_Range3:Input_value3 <TA<= Inputvalue4
TA_RED_Range4:Input_value4 <TA<= Inputvalue5
TA_RED_Range5:Input_value5 <TA<= Inputvalue6
TA_RED_Range6:Input_value6 <TA<= Inputvalue7
TA_RED_Range7:Input_value7 <TA


2116 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
Contained in the following commands:
CREATE SCANCTRX, GET SCANCTRX, SET SCANCTRX
TIMEDTBFREL
timeDelayTBFRelease
This attribute is used to delay the release of a DL Temporary Block Flow (TBF).
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TIMERFHO
timerFHO
This attribute specifies the timer running in the BTS that controls the duration of how
long a former serving cell, from which forced handover was performed to the new
serving cell, may not be
considered in the handover decision algorithm for power budget handovers of the new
serving cell and may not be contained in the target cell list. It is started during the
rangeBound1 0 - 216
rangeBound2 0 - 216
rangeBound3 0 - 216
rangeBound4 0 - 216
rangeBound5 0 - 216
rangeBound6 0 - 216
rangeBound7 0 - 216
rangeBound1 1
rangeBound2 2
rangeBound3 3
rangeBound4 4
rangeBound5 5
rangeBound6 6
rangeBound7 7
0 - 49 (100 msec step size)
15


A30808-X3247-M230-6-7619

2117
CML:BSC t
Id:0900d805800d6bfc
Directed Retry procedure at the reception of a Channel Activation message containing
a Cell Identifier (no target) IE in the 'directed retry target BTS'.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
TINHBAKHO
timerInhibitBackHo
The attribute is used to prevent back handover towards the originating cell for Power
Budget and Traffic reasons when the previous handover was performed for Imperative
and Power Budget reasons..
Validity Range
Default Value
30
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
TINHFAIHO
timerInhibitFailHo
The attribute specifies the timer used by the BTS to exclude a cell from the target cell
list, when the threshold MAXFAILHO has been reached.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, CREATE ADJC3G, GET ADJC, GET ADJC3G, SET ADJC, SET
ADJC3G
TINHRDGR
timerInhibitRateDowngrade
1 - 320 (10 sec step size)
12
1 - 254 (1 sec unit)
1 - 254 (1 sec unit)
7


2118 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
The attribute specifies the minimum time between an upgrade to 14.4kbit/s and the next
downgrade request.
Validity Range
Default Value
52 SACCH multiframes
Contained in the following commands:
GET HAND, SET HAND
TINHRUGR
timerInhibitRateUpgrade
The attribute specifies the minimum time between a downgrade to 9.6 kbit/s and the next
upgrade request.
Validity Range
Default Value
10 2 SACCH multiframes
Contained in the following commands:
GET HAND, SET HAND
TINOIERCHO
timerNoIntraCellHo
This attribute specifies the timer used by the cell to indicate how long no quality or AMR
Intracell Handover has to be generated for a specific connection in the cell if the thresh-
old MAIRACHO + 1 is reached.
Validity Range
Default Value
Contained in the following commands:
GET HAND, SET HAND
TINT
tint
2 - 100 (2 SACCH multiframes unit)
<NULL>
2 - 100 (2 SACCH multiframes unit)
<NULL>
1 - 254 (1 sec step size)
60


A30808-X3247-M230-6-7619

2119
CML:BSC t
Id:0900d805800d6bfc
Wait to report the abnormal release to the maintenance function.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TINTUNIT
tIntUnit
This read-only parameter defines the measurement unit for the TINT timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TNOCH
timerNotificationChannel
The timerNotificationChannel is used for the minimum repetition period for notification
message.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TNSVCBLK
timerInNsvcBlockProcedure
This timer defines the waiting time for NSVC block/unblock
0 - 255 (units of 5 sec)
36
MS100 msec unit
HLFSEC
SEC5
1 - 254
1


2120 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
procedure. After a NSVC block/unblock message sent, the PCU waits TNSVCBLK
seconds for acknowledge.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
TNSVCPTST
timerInNsvcPeriodicTestProcedure
This timer defines the waiting time for NSVC test procedure. If after TNSVCPTST sec.
no answers to test procedure are received, the test procedure shall be retried.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
TNSVCR
timerInNsvcResetProcedure
This timer defines the waiting time for NSVC reset procedure. After a NSVC reset
message sent, the PCU waits TNSVCR seconds for acknowledge.
1 - 10 s
The default of TNSVCBLK depends on the value of
GBSNS attribute:
GBSNS FRFIX IPV4
TNSVCBLK 3 NULL
<NULL>
1 - 10 s
3


A30808-X3247-M230-6-7619

2121
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
TNSVCTST
timerInNsvcTestProcedure
This timer defines the periodicity of the NSVC test procedure. The test messages are
sent to SGSN when NSVC is available every TNSVCTST times.
Validity Range
Default Value
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
TO
testObject
This attribute defines the test number. This number is shown after the execution of the
PERFTEST command in the field BSCETEST:<test_n>.
Validity Range
Default Value
None.
Contained in the following commands:
STOPTEST BSCE
1 - 10 s
The default of TNSVCBLK depends on the value of
GBSNS attribute:
GBSNS FRFIX IPV4
TNSVCBLK 3 NULL
<NULL>
1 - 60 s
30
0 - 255 Pathname defined by means of BSCET-
EST:<bscetest_n>, where <bscetest_n> is equal to
0..255.


2122 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TOPOREL
topologicalRelationship
This is a read-only parameter which represents the topological
relationship between the selected object and the other managed objects that are phys-
ically or functionally joined to it, according to the real network configuration.
Validity Range
Default Value
None.
Contained in the following commands:
GET BTSM, GET PCMA, GET PCMS, GET SS7L, GET TRAU
TOTERM
toTermination
This attribute identifies the timeslot to which the cross connection ends (the information
is spilled out).
Validity Range
Default Value
None.
Contained in the following commands:
CREATE NUC, GET NUC
TPFCBUFF
timerPFCBuffer
This timer is defined for each allocated PFC_Buffer. It is started when PFC_Buffer gets
empty. It is stopped and cancelled if new LLC Frames are coming for that PFC_Buffer.
When it expires, the relative PFC_Buffer is de-allocated and Downlink TBF Scheduling
Weight Updating Algorithm is started.
1 to 9 items of
<ANY>
PcmLine Pathname PCMA: pcma#
PCMB: pcmb#
PCMS: pcms#
Tsl 1 - 31 1..31 for PCM30
1..24 for PCM24


A30808-X3247-M230-6-7619

2123
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TRACE
debuggingCodedString
Debugging coded string.
Validity Range
Default Value
NULL
Contained in the following commands:
CREATE X25A, CREATE X25D, GET X25A, GET X25D, SET X25A, SET X25D
TRACECH
tracedChannel
Validity Range
Default Value
Contained in the following commands:
CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED
TRACEMG
traceMeasureGranularity
This parameter allows to modify the granularity of time for trace measurement reports.
5 - 30 s
20
0..10 characters string
This attribute specifies the type of channel to trace in this
particular cell.
TCH 0
SDCCH 1
BOTH 2
TCH


2124 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TRACEMR
traceMeasureReport
This parameter allows to enable or disable the trace measurement reports.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TRACERECTYP
traceRecordType
This attribute specifies the kind of data to be collected.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CTRSCHED, GET CTRSCHED, SET CTRSCHED
TRACEREF
traceReference
This parameter defines the trace reference.
1 - 254
1
TRUE
FALSE
TRUE
Message
All


A30808-X3247-M230-6-7619

2125
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
NULL
Contained in the following commands:
UPLIMSITR TRACE
TRANSPM
transparentPerformanceMeasurements
This attribute is used to enable/disable implemented performance measurements (e.g.
USSD measurements), which are transparent for the BSC. If this attribute is enabled
then all measurements relevant to the USSD measurement types will be stepped.
Because these messages are transparent for call processing, the activation of these
counters will lead to a reduction of the call processing performance at the TDPC. If this
attribute is disabled then all measurements relevant to the USSD measurement types
will not be stepped and there are no call processing impacts at the TDPC. The counter
result values will then always show zero, although if they were activated by Scanner
Class SCANBTS.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TREL
trel
Wait for release complete message.
Validity Range
Default Value
20 for CCITT
30 for ANSI
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
0 - 65535
TRUE
FALSE
FALSE
0 - 255 0..255 unit of half a second for CCITT
20..40 unit of half a second for ANSI


2126 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TRELUNIT
trelUnit
This read-only parameter defines the measurement unit for the TREL timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TRESEL
timerReselection
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
MS100 msec unit
HLFSEC
SEC5
If the MS has performed an abnormal release with cell reselection
from this cell, the MS is not allowed to reselect this cell for TRESEL
seconds if another cell is available.
The following list shows the correspondence between selected
values and real values:
0 5 s
1 10 s
2 15 s
3 20 s
4 30 s
5 60 s
6 120 s
7 300 s
0 - 7
0


A30808-X3247-M230-6-7619

2127
CML:BSC t
Id:0900d805800d6bfc
TRFCT
trafficControlTimer
This parameter establishes for each BTS the period of time to wait before evaluating the
traffic level. Default value 20 corresponds to 10 seconds.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
TRFHITH
trafficHighThreshold
This parameter defines the high traffic level threshold in order to establish if the
handover for traffic reason has to be enabled/disabled. The value of the parameter is
given in percentage form.
Validity Range
Default Value
90
Contained in the following commands:
GET HAND, SET HAND
TRFHOE
trafficHandoverEnable
This parameter allows to enable/disable the handover for traffic reason feature in the
BTS.
Validity Range
Default Value
FALSE
10 - 200 half-seconds
20
50 - 100
<NULL>
TRUE
FALSE
<NULL>


2128 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Contained in the following commands:
GET HAND, SET HAND
TRFHOM
trafficHandoverMargin
This parameter defines the nominal cell border between cells. The set value ranges from
-63 dB to +63 dB (1 dB step size).
Validity Range
Default Value
67 [+4 dB]
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
TRFHORXLVMOFF
trafficHoRxLevMinOffset
Values expressed in dB.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
TRFHOT
trafficHandoverTimer
0 - 126
<NULL>
This attribute defines a neighbour cell specific level offset that is
added to RXLREVMIN value of a particular neighbour cell, during the
target cell list generation for traffic handover. Iis foreseen in order to
make sure that a traffic handover is only attempted towards those
target cells that provide sufficient service quality conditions
It enhances the minimum criteria defined by the attribute
RXLEVMIN.
-24 - 24 (1 dB step size)
<NULL>
6


A30808-X3247-M230-6-7619

2129
CML:BSC t
Id:0900d805800d6bfc
This parameter represents the timer which is used to establish the period of time to wait
before updating the m value. The m value is increased if the handover for traffic reason
is enabled and decreased if the handover for traffic reason is disabled, m is updated until
it reaches value 0.
Validity Range
Default Value
10
Contained in the following commands:
GET HAND, SET HAND
TRFKPRI
trafficKeepPriority
This parameter determines whether candidate cells have to be of the same priority as
the serving cell or may be of the same or higher priority.
Validity Range
Default Value
FALSE
Contained in the following commands:
GET HAND, SET HAND
TRFLTH
trafficLowThreshold
This parameter defines the low traffic level threshold in order to
establish if a cell can be a candidate to receive handover for traffic reason. The value of
the parameter is given in percentage form.
Validity Range
Default Value
70
2 - 20
<NULL>
TRUE
FALSE
<NULL>
0 - 85
<NULL>


2130 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Contained in the following commands:
GET HAND, SET HAND
TRFMMA
trafficMarginMaximum
This parameter establishes the maximum reduction for TRFHOM.
Validity Range
Default Value
9
Contained in the following commands:
GET HAND, SET HAND
TRFMS
trafficMarginStep
This parameter establishes the minimum reduction for TRFHOM.
Validity Range
Default Value
3
Contained in the following commands:
GET HAND, SET HAND
TRFPS
trafficPs
This parameter defines the flag enbling the traffic control algorithm
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
1 - 48 dB.
<NULL>
1 - 6 dB.
<NULL>
TRUE
FALSE
FALSE


A30808-X3247-M230-6-7619

2131
CML:BSC t
Id:0900d805800d6bfc
TRFPSCTRLT
trafficPSControlTimer
Minimum time between two consecutive cell reselection procedures ordered or assisted
by network (through Packet Cell Change Order or Packet Cell Change Continue mes-
sages) on the same MS towards the same adjacent cell.
Validity Range
Default Value
Contained in the following commands:
CREATE PTPPKF, GET PTPPKF, SET PTPPKF
TRXAREA
trxArea
The attribute specifies whether a TRX belongs to a concentric cell and to which area it
belongs.
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
TRXFREQ
carrierFrequency
This attribute is used to assign a constant radio frequency to a transceiver. The signifi-
cance of this attribute is implementation dependent.
The frequencies set to "cellAllocation" attribute must follow these rules:
if SYSID = BB900 then 1 =< frequency =< 124
if SYSID = EXT900 then 0 =< frequency =< 124
975 =< frequency =< 1023
1 - 100
12
NONE
INNER
COMPLETE
NONE


2132 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
if SYSID = DCS1800 then 512 =< frequency =< 885
if SYSID = GSMR then 955 =< frequency =< 974
if SYSID = PCS1900 then 512 =< frequency =< 810
In case of EXT900 the extended band (frequencies 0, 975...1023) can be used only for
the traffic purposes and for phase 2 mobile, no interaction between the two bands (base
and extended) is foreseen and the base band can be used also by phase 1 mobile.


A30808-X3247-M230-6-7619

2133
CML:BSC t
Id:0900d805800d6bfc
Validity Range
bcchFreq
callf01
callf02
callf03
callf04
callf05
callf06
callf07
callf08
callf09
callf10
callf11
callf12
callf13
callf14
callf15
callf16
callf17
callf18
callf19
callf20
callf21
callf22
callf23
callf24
callf25
callf26
callf27
callf28
callf29
callf30
callf31
callf32
callf33
callf34


2134 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
callf35
callf36
callf37
callf38
callf39
callf40
callf41
callf42
callf43
callf44
callf45
callf46
callf47
callf48
callf49
callf50
callf51
callf52
callf53
callf54
callf55
callf56
callf57
callf58
callf59
callf60
callf61
callf62
callf63
ccallf01
ccallf02
ccallf03
ccallf04
ccallf05
ccallf06
ccallf07


A30808-X3247-M230-6-7619

2135
CML:BSC t
Id:0900d805800d6bfc
ccallf08
ccallf09
ccallf10
ccallf11
ccallf12
ccallf13
ccallf14
ccallf15
ccallf16
ccallf17
ccallf18
ccallf19
ccallf20
ccallf21
ccallf22
ccallf23
ccallf24
ccallf25
ccallf26
ccallf27
ccallf28
ccallf29
ccallf30
ccallf31
ccallf32
ccallf33
ccallf34
ccallf35
ccallf36
ccallf37
ccallf38
ccallf39
ccallf40
ccallf41
ccallf42
ccallf43


2136 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Default Value
None.
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
TRXFREQV
carrierFrequencyValue
This read-only parameter defines the value of TRX frequency.
Validity Range
Default Value
None.
Contained in the following commands:
GET TRX
ccallf44
ccallf45
ccallf46
ccallf47
ccallf48
ccallf49
ccallf50
ccallf51
ccallf52
ccallf53
ccallf54
ccallf55
ccallf56
ccallf57
ccallf58
ccallf59
ccallf60
ccallf61
ccallf62
ccallf63
0 - 1023


A30808-X3247-M230-6-7619

2137
CML:BSC t
Id:0900d805800d6bfc
TRXMD
trxMode
This parameter states if TRX should be associated to a board with EDGE capabilities.
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
TSBS
tsbs
State information.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TSBSUNIT
tsbsUnit
This read-only parameter defines the measurement unit for the TSBS timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
GSM
EDGE
GSM
0 - 255 units of half a second
60
MS100 msec unit
HLFSEC
SEC5


2138 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TSC
trainingSequenceCode
Specifies the Training Sequence Code of a radio channel. If TSC is not set the training
sequence code is taken from the BCC of the BSIC attribute in the BTS command.
Validity Range
Default Value
This value indicates that the attribute is equal to BCC value of BSIC attribute in BTS
object.
Contained in the following commands:
CREATE CHAN, GET CHAN, SET CHAN
TSLA
tsla
Identifies the pcma number and the timeslot number for allocation of ss7 link.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE SS7L, GET SS7L
TSNPRO
timeSubnetworksProcedure
This attribute defines the timeout for IP SNS (Sub Network Service) Procedures.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
0 - 7
<NULL>
pcmaNumber 0 - 191
tslNumber 1 - 31 1..31 for PCM30 line
1..24 for PCM24 line
1 - 10
<NULL>


A30808-X3247-M230-6-7619

2139
CML:BSC t
Id:0900d805800d6bfc
TSULBAL
timeSwitchULBalanced
This attribute represents the timer to switch to UL balanced method.
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
TSYNC
tSync
Recommended default value > or = to 200.
Validity Range
Default Value
In moc(s) TRAU:
In moc(s) BTS:
Contained in the following commands:
CREATE BTS, CREATE TRAU, GET BTS, GET TRAU, SET BTS, SET TRAU
0 - 100 (unit : 100ms)
20
Note It's recommended to set the related values of timers T3109 and
TSYNC respecting the following rule:
T3109+2sec<TSYNC
If default values are set not respecting the above rule, please change
the values with SET command.
This attribute defines the timer value which is used by the BTS to
supervise time-out of TRAU frame handling. This timer is used only
if a BTS-TRAU traffic connection is already established. It is started
after 3 TRAU-frames have not been correctly received and is cleared
if a frame is received again. If it expires at BTS side, a connection
failure indication is reported to the BSC; if it expires at TRAU side a
warning is generated.
10 - 10000 (100 ms step size)
100
1000


2140 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TSYNCDL
tSynchronizationDownlink
If tSyncDL expires a Connection Failure with cause Remote Transcoder Failure is sent
to the BSC.
Validity Range
Default Value
1000
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TSYNCR
tSynchronizationR
The timer starts if the control bit 'uplink frame error' (UFE) indicates an error and no error
on the synchronization pattern is detected. If tSyncR expires the BTS starts sending
data frames.
Validity Range
Default Value
400
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TSYNCUL
tSynchronizationUplink
The timer starts if the control bit 'uplink frame error' (UFE) indicates an error and no error
on the synchronization pattern is detected. If tSyncUL expires a Connection Failure with
cause Remote Transcoder Failure is sent to the BSC.
Validity Range
Default Value
1000
10 - 10000 (10ms unit)
<NULL>
10 - 10000 (10ms unit)
<NULL>
10 - 10000 (10ms unit)
<NULL>


A30808-X3247-M230-6-7619

2141
CML:BSC t
Id:0900d805800d6bfc
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TTRAU
tTrau
This attribute defines the timer value which is used by the BTS to supervise time-out of
TRAU datalink (traffic) at connection
establishment or handover. It is set when sending the first TRAU data frame uplink and
cleared when the first frame downlink arrives. If it expires, a connection failure indication
is reported to the BSC.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TUESP
timerUeSpeed
The attribute specifies is used Mobile Speed Sensitive NC GSM/GPRS to UMTS cell
reselection. An UMTS microcell is only included in the UMTS target cell list, if the thresh-
old condition for "sufficient UMTS coverage" is met during the whole timer period. A "fast
moving" mobile will violate this timer condition and therefore, NC cell reselection from a
GSM/GPRS serving cell to this UMTS microcell is not performed for a "fast moving"
mobile. Values expressed in seconds.
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
TUPLREP
timerUplinkReply
This timer is used by BTS for starting the uplink reply procedure. Values expressed in
seconds.
10 - 10000 (10 ms step size. Recommended value > or = to 150)
1000
0 - 100
5


2142 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
Default Value
20
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TWCUNIT
twcUnit
This read-only parameter defines the measurement unit for the TWCUSER timer.
Validity Range
Default Value
None.
Contained in the following commands:
GET OPC
TWCUSER
twcUser
Manufacturer dependent timer.
Validity Range
Default Value
Contained in the following commands:
CREATE OPC, GET OPC, SET OPC
TXDIVTSEXCPT
txDivTimeShiftExcept
This parameter allows to configure time slots or logical channels which are excluded
from being sent in TX diversity Time Shift mode.
5 - 60 s.
<NULL>
MS100 msec unit
HLFSEC
SEC5
0 - 255 (units of half a second)
20


A30808-X3247-M230-6-7619

2143
CML:BSC t
Id:0900d805800d6bfc
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TXDIVTSPAR
txDivTimeShiftParam
This parameter defines the time shift of the TX signals of master and slave CU. The
attribute is meaningless if ETXDIVTS parameter is set at FALSE.
NONE
SCH
BCCHTRXTS0
BCCHTRX
NONE


2144 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
Validity Range
MDB5
MDB475
MDB45
MDB425
MDB4
MDB375
MDB35
MDB325
MDB3
MDB275
MDB25
MDB225
MDB2
MDB175
MDB15
MDB125
MDB1
MDB075
MDB05
MDB025
DB0
DB025
DB05
DB075
DB1
DB125
DB15
DB175
DB2
DB225
DB25
DB275
DB3
DB325
DB35


A30808-X3247-M230-6-7619

2145
CML:BSC t
Id:0900d805800d6bfc
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
TYPOFAMC
typeOfAlarmModuleCard
This attribute indicates the type of Alarm Module Card.
Validity Range
Default Value
None.
Contained in the following commands:
GET BSC, SET BSC
TYPOFETH
typeOfEthernet
This attribute indicates the type of Ethernet adopted for the internal LAN.
Validity Range
Default Value
Contained in the following commands:
GET BSC, SET BSC
DB375
DB4
DB425
DB45
DB475
DB5
MDB1
DK40 (0)
CPEX (1)
ES (2)
ETHERNETII
IEEE802
ETHERNETII


2146 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d6bfc
t
TYPOFNSVCCONF
typeOfNSVCConfiguration
This attribute indicates the method of configuration of the NS-VCs for the IP sub network
service.
Validity Range
Default Value
The default of TYPOFNSVCCONF depends on the value of GBSNS attribute:
GBSNS FRFIX IPV4
TYPOF NSVCCONF NULL STATIC
Contained in the following commands:
CREATE PCU, GET PCU, SET PCU
TYPPROC
typeProcessor
This attribute identifies the processor.
Validity Range
Default Value
MPCC_ACT
Contained in the following commands:
MEMDUMP BSC
STATIC
DYNAMIC
<NULL>
MPCC_ACT
MPCC_SBY
TDPC_ACT
TDPC_SBY


A30808-X3247-M230-6-7619

2147
CML:BSC u
Id:0900d805800d533d
u
UADJ
umtsAdjust
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
ULAB
userLabel
This parameter assigns a user friendly name (is a user-defined string) to the BSC Exe-
cutable Software Unit DB (note it is the same of the related BSC Reusable Software Unit
DB).
Validity Range
Default Value
None.
This attribute is used in "Better Cell Handover" from GSM to UMTS
to adjust the carrier level of the related UMTS adjacent cell
compared to the carrier level of the serving cell.
The parameter is coded according to the following table:
0 - 63 dB
1 - 62 dB
...; ...;
62 - 1 dB
63 0 dB
64 + 1 dB
... ...
125 + 62 dB
126 + 63 dB
0 - 126
63
1..30 characters string


2148 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d533d
u
Contained in the following commands:
CREATE RSUDB, CREATE RSUPCH, CREATE RSUSWLH, GET BSCESUDB,
GET BSCESUSW, GET NEYESUSW, GET RSUDB, GET RSUPCH, GET
RSUSWLH, SET RSUDB, SET RSUSWLH
ULABSWLH
userLabelSwLoadHeader
This parameter defines the user label of the software load header and it consists of 30
characters string.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE RSUEXE, CREATE RSUPCH
UMECNO
umtsMinEcNo
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
1..30 characters string
This attribute defines the minimum level which is required to include
an UMTS FDD cell into the handover target cell list in case of an
"Imperative HO"; it is valid only for FDD cells in case
FDDREPQTY = EC_N0.
The parameter is coded according to the following table:
0 CPICH Ec/No < - 24 dB
1 - 24 dB <= CPICH Ec/No < - 23.5 dB
...; ...;
48 - 0.5 dB <= CPICH Ec/No < 0 dB
49 0 dB <= CPICH Ec/No
0 - 49
19


A30808-X3247-M230-6-7619

2149
CML:BSC u
Id:0900d805800d533d
UMTSSRHPRI
umtsSearchPriority
This parameter indicates if mobile can search 3G cells when BSIC decoding is required,
i.e. if the searching time can be longer than normal value (13 s instead of 10 s).
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
UPGRFREQ
UpgradeFrequency
This attribute defines the periodicity of radio resources upgrade attempts on packet ser-
vices.
TRUE
FALSE
TRUE


2150 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d533d
u
Validity Range
Default Value
Contained in the following commands:
CREATE CPCU, GET CPCU, SET CPCU
UPTLEVD
pcUpperThresholdLevDL
This attribute defines the upper threshold of the received signal level on downlink for
power reduction.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
Uplink SEC1
SEC2
SEC3
SEC4
SEC5
SEC6
SEC7
SEC8
Downlink SEC1
SEC2
SEC3
SEC4
SEC5
SEC6
SEC7
SEC8
Uplink SEC1
Downlink SEC1
0 - 63 dBr.
For the values make references to Appendix B: Group 2.
36


A30808-X3247-M230-6-7619

2151
CML:BSC u
Id:0900d805800d533d
UPTLEVU
pcUpperThresholdLevUL
This attribute defines the upper threshold of the received signal level on uplink for power
reduction.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
UPTQUAD
pcUpperThresholdQualDL
This attribute defines the upper threshold of the received signal quality on downlink for
power reduction.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
UPTQUAMRDL
pcUpperThresQualAMRDL
This parameter determines the upper power control downlink quality threshold for AMR
calls. In case of an AMR call UPTQUAMRDL eclipses the threshold UPTQUAD, i.e. for
AMR calls the power control algorithm decreases the DL transmit power if the quality
exceeds the threshold determined by UPTQUAMRDL. As UPTQUAMRDL is entered in
C/I values, but the MS reports the serving cell quality in form of RXQUAL values, the
BTS performs an internal mapping of RXQUAL to C/I values prior to the power control
decision.
0 - 63 dBr.
For the values make references to Appendix B: Group 2.
36
0 - 7 For the values make references to Appendix B: Group 3.
2


2152 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d533d
u
Validity Range
Default Value
13
Contained in the following commands:
GET PWRC, SET PWRC
UPTQUAMRUL
pcUpperThresQualAMRUL
This parameter determines the upper power control uplink quality threshold for AMR
calls. In case of an AMR call UPTQUAMRUL eclipses the threshold UPTQUAU, i.e. for
AMR calls the power control algorithm decreases the UL transmit power if the quality
exceeds the threshold determined by UPTQUAMRUL. As UPTQUAMRUL is entered in
C/I values, but the BTS measures the serving cell quality in form of RXQUAL values, the
BTS performs an internal mapping of RXQUAL to C/I values prior to the power control
decision.
Validity Range
Default Value
13
Contained in the following commands:
GET PWRC, SET PWRC
UPTQUAU
pcUpperThresholdQualUL
This attribute defines the upper threshold of the received signal quality on uplink for
power reduction.
Validity Range
Default Value
Contained in the following commands:
GET PWRC, SET PWRC
0 - 20 (1dB step size)
<NULL>
0 - 20 (1dB step size)
<NULL>
0 - 7 For the values make references to Appendix B: Group 3.
2


A30808-X3247-M230-6-7619

2153
CML:BSC u
Id:0900d805800d533d
USECNO
umtsSuffEcNo
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
USECNONCRESEL
umtsSuffEcNoNcResel
This attribute defines the threshold above which BTS initiates a "Suf-
ficient UMTS Coverage HO " from GSM to UMTS in case of FDD
when FDDREPQTY attribute is set at EC_N0 value.
The parameter is coded according to the following table:
0 CPICH Ec/No < - 24 dB
1 - 24 dB <= CPICH Ec/No < - 23.5 dB
... ...
48 - 0.5 dB <= CPICH Ec/No < 0 dB
49 0 dB <= CPICH Ec/No
0 - 49
23
This attribute defines the sufficient Ec/No threshold above which
BSC initiates a "NC cell reselection from GSM/GPRS to UMTS due
to sufficient UMTS coverage". For FDD cells this attribute is mean-
ingful if the parameter FDD_REP_QUANT is set to Ec/No reporting;
for TDD cells it is never used.
The parameter is coded according to the following table:
0 Ec/No < - 24 dB
1 - 24 <= Ec/No < - 23,5 dB
... ...
48 - 0,5 <= Ec/No < 0 dB
49 0 <= Ec/No


2154 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d533d
u
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
USFGRAN
uSFGranularity
This attribute defines if USF granularity 1 is supported or not..
Validity Range
Default Value
Contained in the following commands:
CREATE TRX, GET TRX, SET TRX
USG
usage
This attribute indicates whether the adjacent cell must be sent over system information
2, 5 or both when active, or if it is used only for measurement purposes (inactive).
Validity Range
Default Value
Contained in the following commands:
CREATE ADJC, GET ADJC, SET ADJC
0 - 49
19
DISABLED
ENABLED
DISABLED
SI_2
SI_5
SI_2_5
INACTIVE
SI_2_5


A30808-X3247-M230-6-7619

2155
CML:BSC u
Id:0900d805800d533d
USRSCP
umtsSuffRscp
Validity Range
Default Value
8 for FDD
18 for TDD
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
USRSCPNCRESEL
umtsSuffRscpNcResel
This attribute defines the threshold above which BTS initiates a
"Sufficient UMTS Coverage HO " from GSM to UMTS in case of TDD
adjacent cell or in case of FDD when FDDREPQTY attribute is set at
RSCP value. The variable default must be managed depending on
whether the adjacent cell is a TDD or a FDD one.
The parameter is coded according to the following table:
0 RSCP < - 115 dBm
1 - 115 dBm <= RSCP < - 114 dBm
...; ...;
62 - 54 dBm <= RSCP < - 53 dBm
63 - 53 dBm <= RSCP
0 - 63
<NULL>
This attribute defines the sufficient RSCP threshold above which
BSC initiates a "NC cell reselection from GSM/GPRS due to suffi-
cient UMTS coverage". For FDD cells this attribute is meaningful if
the parameter FDD_REP_QUANT is set to RSCP reporting; for TDD
cells it is always used.
The parameter is coded according to the following table:
0 RSCP < - 115 dBm
1 - 115 <= RSCP < - 114 dBm
...; ...;
62 - 54 <= RSCP < - 53 dBm
63 - 53 <= RSCP < - 52 dBm


2156 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d533d
u
Validity Range
Default Value
8 for FDD
18 for TDD
Contained in the following commands:
CREATE ADJC3G, GET ADJC3G, SET ADJC3G
0 - 63


A30808-X3247-M230-6-7619

2157
CML:BSC v
Id:0900d805800cecec
v
VER
version
This read-only parameter defines the version of the managed element.
Validity Range
In commands GET BSCESUSW, GET NEYESUSW, GET RSUEXE, GET RSUSWLH:
In commands GET MEL:
Default Value
None.
Contained in the following commands:
GET BSCESUSW, GET MEL, GET NEYESUSW, GET RSUEXE, GET RSUSWLH
VGRULF
voiceGroupUplinkFree
The voice GroupUplinkFree is used for the repetition of the UPLINK_FREE message.
If the uplink of the group call is free, and also no talker is in the cell on a dedicated
channel, the network provides an UPLINK FREE message on the main signalling
channel periodically.
The timer defined using VGRULF, plus an offset of 440ms, defines the repetition rate of
sending this message; the BTS limits the maximum repetition rate on 1450ms:
UPLINK FREE repetition rate = MIN ((440ms + (value of VGRULF * 10ms)), 1450ms).
BTS stops the timer when the uplink is free again, and also no talker is in the cell on a
dedicated channel.
3GPP TS04.18 specifies that a mobile station may start the uplink access procedure if
an UPLINK FREE was received during the last 480ms, and no UPLINK BUSY was
received following. Otherwise, the mobile station waits up to 1s for an UPLINK FREE.
Setting this attribute to the lowest possible value means that a talker request by a mobile
station can be started with most minimal delay.
On the other side, a high repetition rate of UPLINK FREE messages leads to a certain
speech frame erasure rate, which may cause an audible degradation of the speech
quality on the group downlink channel; also there is no talker in the group call at this
state, there may be dispatchers speaking on the group downlink channel.
For example, if VGRULF is set to 1, then
UPLINK_FREE_repetition_rate =MIN ((440ms + 1 * 10ms)), 1450ms) = 450ms
1..26 characters string
1..81 characters string


2158 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecec
v
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
VOLDL
volumeDownlink
Indicates a value for the time slot volume attenuation in downlink direction (MSC --->
MS). Default value 12 corresponds to 0 dB.
Validity Range
Default Value
Contained in the following commands:
GET TSLA, SET TSLA
VOLUL
volumeUplink
Indicates a value for the time slot volume attenuation in uplink direction (MS --> MSC).
Dafault value 12 corresponds to 0 dB.
Validity Range
Default Value
Contained in the following commands:
GET TSLA, SET TSLA
1 - 100
1
0 - 24 (1 dB step size)
where:
0 = -12 dB
24 = 12 dB
12
0 - 24 (1 dB step size).
where:
0 = -12 dB
24 = 12 dB
12


A30808-X3247-M230-6-7619

2159
CML:BSC v
Id:0900d805800cecec
VQEST
voiceQualityEnhancementStatus
This attribute enables/disables the Voice Quality Enhancement (VQE) feature set..
Validity Range
Default Value
Contained in the following commands:
CREATE TRAU, GET TRAU, SET TRAU
disabled
enabled
disabled


2160 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecef
w
w
WEID
weightData
This attribute defines the weight related to local IP endpoint for data.
Validity Range
Default Value
Contained in the following commands:
CREATE NSVLIP, CREATE RNSVLIP, GET NSVLIP, GET RNSVLIP, SET NSVLIP,
SET RNSVLIP
WEIS
weigthSignalling
This attribute defines the weight related to local IP endpoint for signalling.
Validity Range
Default Value
Contained in the following commands:
CREATE NSVLIP, CREATE RNSVLIP, GET NSVLIP, GET RNSVLIP, SET NSVLIP,
SET RNSVLIP
WMOD
workingMode
This attribute indicates whether the created PCMS or PCMB will be required to work in
Single Trunk Mode or in Double Trunk Mode.
0 - 255
10
0 - 255
10


A30808-X3247-M230-6-7619

2161
CML:BSC w
Id:0900d805800cecef
Validity Range
Default Value
Contained in the following commands:
CREATE PCMB, CREATE PCMS, GET PCMB, GET PCMS
WPSPREF
wPSPreference
This attribute specifies which is the complete cycling period in terms of number of calls
served and for each complete cycle period how many WPS requests should be consec-
utively served.
Validity Range
Default Value
Contained in the following commands:
CREATE BTS, GET BTS, SET BTS
WRTYP
wordType
This parameter forces the type of asynchronous mode of PLLH.
Validity Range
Default Value
None.
Contained in the following commands:
FORCSYNC NTW
DOUBLE_TRUNK
SINGLE_TRUNK
DOUBLE_TRUNK
counterCycle 2 - 10
numberWPS 1 - 3
counterCycle 4
numberWPS 1
Tune
DAC


2162 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800cecf2
x
x
X121ADDR
x121Addr
This attribute indicates the X25 network address.
Validity Range
Default Value
None.
Contained in the following commands:
CREATE CBCL, CREATE OMAL, GET CBCL, GET OMAL, SET OMAL
1..33 characters string
<NULL>


A30808-X3247-M230-6-7619

2163
CML:BSC Appendix A: ME-Address Value List
Id:0900d805800d1cad
5 Appendix A: ME-Address Value List
This appendix contains the list of the ME (Maintenance Entity) address accepted values
for the relevant managed objects.
ME-Address Accepted Values
<adjc> 0..63
<adjc3g> 0..63
<bsce> 0..0
<bsc> 0..0
<bscesudb> 0..19
<bscesusw> 0..19
<bscetest> 0..255
<bscosudb> 0..0
<bscosusw> 0..0
<btsm> 0..199
<btsmosusw> 0..0
<bts> 0..23
<cbcl> 0..1
<cbts> 0..0
<cfhsy> 0..1
<chan> 0..7
<cpex> 0..1
<cpcu> 0..11
<ctrco> 0..0
<ctrsched> 0..31
<dk40> 0..0
<disk> 0..1
<enva> 0..20
<epwr> 0..1
<es> 0..1
<fan> 0..0
<fhsy> 1..10
<filehandler> 0..0
<frl> 0..755
<gbiplnk> 0..1
<hand> 0..0


2164 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800d1cad
Appendix A: ME-Address Value List
<hdctr> 0..0
<ipli> 0..0
<ixlt> 0..1
<licd> 0..9
<licds> 0..1
<lpdlm> 0..10
<lpdlr> 0..0
<lpdls> 0..0
<mel> 0..0
<memt> 0..1
<mpcc> 0..1
<neyesusw> 0..39
<nsvc> 0..755
<nsvcip> 0..255
<nsvlip> 0..15
<ntw> 0..1
<nuc> 0..29
<omal> 0..1
<opc> 0..0
<pcma> 0..191
<pcmb> 0..117
<pcmg> 0..31
<pcms> 0..47
<pcu> 0..11
<ppxl> 0..1
<ppxu> 0..11
<ptppkf> 0..0
<pwrc> 0..0
<pwrd> 0..1
<reminv> 0..0
<qsmonbsc> 0..0
<qsmonbts> 0..0
<qsmonbtsco> 0..0
<qsmongprs> 0..0
<qsmongprsco> 0..0
<qsthrs> 0..49


A30808-X3247-M230-6-7619

2165
CML:BSC Appendix A: ME-Address Value List
Id:0900d805800d1cad
<rfloop> 0..0
<rnsvlip> 0..15
<rsudb> 0..19
<rsuexe> 0..249
<rsupch> 0..399
<rsuswlh> 0..59
<scan XXX> 0..89
0..4 (SCANGPRS case)
0..0 (SCANCO case)
<sca> 0..0
<ss7l> 0..16
<ss7s> 0..1
<subtslb> 0..3
<sync> 0..47
<synco> 0..0
<syne> 0..1
<sysinit> 0..0
<tdpc> 0..1
<tgtbts> 0..1499
<tgtfdd> 0..1499
<tgttdd> 0..1499
<tgtptppkf> 0..0
<trace> 0..0
<trau> 0..47
<trauosusw> 0..0
<trx> 0..23
<tsla> 1..31
<tslb> 1..31
<tsl> 1..31
<x25a> 0..1
<x25d> 0..1


2166 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6 Appendix B: Special Parameter Values
This appendix contains complete tables with all values for the particular groups of
parameters which are listed below.
Group 1
BCCHFREQ bcchFrequency
Group 2
HOLTHLVDL hoLowerThresholdLevDL
HOLTHLVUL hoLowerThresholdLevUL
HOTDLINT hoThresholdLevDLintra
HOTULINT hoThresholdLevULintra
LOWTLEVD pcLowerThresholdLevDL
LOWTLEVU pcLowerThresholdLevUL
UPTLEVD pcUpperThresholdLevDL
UPTLEVU pcUpperThresholdLevUL
RXLEVMIN rxLevMinCell
Group 3
HOLTHQUDL hoLowerThresholdQualDL
HOLTHQUUL hoLowerThresholdQualUL
LOWTQUAD pcLowerThresholdQualDL
LOWTQUAU pcLowerThresholdQualUL
UPTQUAD pcUpperThresholdQualDL
UPTQUAU pcUpperThresholdQualUL
RUGRDL rateUpgradeDownlink
RUGRUL rateUpgradeUplink
RDGRDL rateDowngradeDownlink
RDGRUL rateDowngradeUplink
RHOLTQDL rateHoLowerThresholdQualDownlink
RHOLTQUL rateHoLowerThresholdQualUplink
Group 4
MSTXPMAXGSM mSTxPwrMaxGsm
MSTXPMAXDCS mSTxPwrMaxDcs
MSTXPMAXPCS mSTxPwrMaxPcs
MSTXPMAXUMTS msTxPwrMaxUmts


A30808-X3247-M230-6-7619

2167
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
Group 5
EPOOL enablePooling
DEFPOOLTYP defPoolType
POOLTYP poolType
Group 6
HOLTHQAMRDL hoLowerThresQualAMRDL
HOLTHQAMRUL hoLowerThresQualAMRUL
HOTHAMRCDL hoThresAMRComprDL
HOTHAMRCUL hoThresAMRComprUL
HOTHAMRDDL hoThresAMRDecomprDL
HOTHAMRDUL hoThresAMRDecomprUL
LOWTQUAMRDL pcLowerThresQualAMRDL
LOWTQUAMRUL pcLowerThresQualAMRUL
UPTQUAMRDL pcUpperThresQualAMRDL
UPTQUAMRUL pcUpperThresQualAMRUL
Group 7
SG1HOPAR sg1HandoverParms
SG2HOPAR sg2HandoverParms
SG3HOPAR sg3HandoverParms
SG4HOPAR sg4HandoverParms
SG5HOPAR sg5HandoverParms
SG6HOPAR sg6HandoverParms
SG7HOPAR sg7HandoverParms
SG8HOPAR sg8HandoverParms
SG9HOPAR sg9HandoverParms
SG10HOPAR sg10HandoverParms
SG11HOPAR sg11HandoverParms
SG12HOPAR sg12HandoverParms
SG13HOPAR sg13HandoverParms
SG14HOPAR sg14HandoverParms
SG1PCPAR sg1PowerControlParms
SG2PCPAR sg2PowerControlParms
SG3PCPAR sg3PowerControlParms
SG4PCPAR sg4PowerControlParms


2168 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.1 Special Parameter Values - Group 1
Group 1
BCCHFREQ = bcchFrequency
The formula to retrieve the Uplink (Fu) and Downlink (Fd) frequencies is the following:
SG5PCPAR sg5PowerControlParms
SG6PCPAR sg6PowerControlParms
SG7PCPAR sg7PowerControlParms
SG8PCPAR sg8PowerControlParms
SG9PCPAR sg9PowerControlParms
SG10PCPAR Sg10PowerControlParms
SG11PCPAR sg11PowerControlParms
SG12PCPAR sg12PowerControlParms
SG13PCPAR sg13PowerControlParms
SG14PCPAR sg14PowerControlParms
Group 8
RADIOMG radioMeasGran
RADIOMR radioMeasRep
Range: 1-124 for P-GSM 900 (Table 1)
0-124, 975-1023 for E-GSM 900 (Table 2, Table 3)
512-885 for DCS 1800 (Table 4)
955-974 for GSM-R (Table 5)
512-810 for PCS 1900 (Table 6)
128-251 for GSM 850 (Table 7)
Frequency Band Type ARFCN (N) Fu Fd
P-GSM 900 1-124 Fu(N) = 890.2 + 0.2*(N-1) Fd(N)=Fu(N)+45
E-GSM 900 0-124 Fu(N) = 890.0 + 0.2*N Fd(N)=Fu(N)+45
E-GSM 900 975-1023 Fu(N) = 880.2 + 0.2*(N-975) Fd(N)=Fu(N)+45
DCS 1800 512-885 Fu(N) = 1710.2 + 0.2*(N-512) Fd(N)=Fu(N)+95
GSM-R 955-974 Fu(N) = 876.2 + 0.2*(N-955) Fd(N)=Fu(N)+45
PCS 1900 512-810 Fu(N) = 1850.2 + 0.2*(N-512) Fd(N)=Fu(N)+80
GSM 850 128-251 Fu(N) = 824.2 + 0.2*(N-128) Fd(N)=Fu(N)+45


A30808-X3247-M230-6-7619

2169
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
1 0001 890.2 935.2 2 0002 890.4 935.4
3 0003 890.6 935.6 4 0004 890.8 935.8
5 0005 891.0 936.0 6 0006 891.2 936.2
7 0007 891.4 936.4 8 0008 891.6 936.6
9 0009 891.8 936.8 10 000A 892.0 937.0
11 000B 892.2 937.2 12 000C 892.4 937.4
13 000D 892.6 937.6 14 000E 892.8 937.8
15 000F 893.0 938.0 16 0010 893.2 938.2
17 0011 893.4 938.4 18 0012 893.6 938.6
19 0013 893.8 938.8 20 0014 894.0 939.0
21 0015 894.2 939.2 22 0016 894.4 939.4
23 0017 894.6 939.6 24 0018 894.8 939.8
25 0019 895.0 940.0 26 001A 895.2 940.2
27 001B 895.4 940.4 28 001C 895.6 940.6
29 001D 895.8 940.8 30 001E 896.0 941.0
31 001F 896.2 941.2 32 0020 896.4 941.4
33 0021 896.6 941.6 34 0022 896.8 941.8
35 0023 897.0 942.0 36 0024 897.2 942.2
37 0025 897.4 942.4 38 0026 897.6 942.6
39 0027 897.8 942.8 40 0028 898.0 943.0
41 0029 898.2 943.2 42 002A 898.4 943.4
43 002B 898.6 943.6 44 002C 898.8 943.8
45 002D 899.0 944.0 46 002E 899.2 944.2
47 002F 899.4 944.4 48 0030 899.6 944.6
49 0031 899.8 944.8 50 0032 900.0 945.0
51 0033 900.2 945.2 52 0034 900.4 945.4
53 0035 900.6 945.6 54 0036 900.8 945.8
55 0037 901.0 946.0 56 0038 901.2 946.2
57 0039 901.4 946.4 58 003A 901.6 946.6
59 003B 901.8 946.8 60 003C 902.0 947.0
61 003D 902.2 947.2 62 003E 902.4 947.4
63 003F 902.6 947.6 64 0040 902.8 947.8
Table 1 Frequency values for P-GSM 900


2170 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
65 0041 903.0 948.0 66 0042 903.2 948.2
67 0043 903.4 948.4 68 0044 903.6 948.6
69 0045 903.8 948.8 70 0046 904.0 949.0
71 0047 904.2 949.2 72 0048 904.4 949.4
73 0049 904.6 949.6 74 004A 904.8 949.8
75 004B 905.0 950.0 76 004C 905.2 950.2
77 004D 905.4 950.4 78 004E 905.6 950.6
79 004F 905.8 950.8 80 0050 906.0 951.0
81 0051 906.2 951.2 82 0052 906.4 951.4
83 0053 906.6 951.6 84 0054 906.8 951.8
85 0055 907.0 952.0 86 0056 907.2 952.2
87 0057 907.4 952.4 88 0058 907.6 952.6
89 0059 907.8 952.8 90 005A 908.0 953.0
91 005B 908.2 953.2 92 005C 908.4 953.4
93 005D 908.6 953.6 94 005E 908.8 953.8
95 005F 909.0 954.0 96 0060 909.2 954.2
97 0061 909.4 954.4 98 0062 909.6 954.6
99 0063 909.8 954.8 100 0064 910.0 955.0
101 0065 910.2 955.2 102 0066 910.4 955.4
103 0067 910.6 955.6 104 0068 910.8 955.8
105 0069 911.0 956.0 106 006A 911.2 956.2
107 006B 911.4 956.4 108 006C 911.6 956.6
109 006D 911.8 956.8 110 006E 912.0 957.0
111 006F 912.2 957.2 112 0070 912.4 957.4
113 0071 912.6 957.6 114 0072 912.8 957.8
115 0073 913.0 958.0 116 0074 913.2 958.2
117 0075 913.4 958.4 118 0076 913.6 958.6
119 0077 913.8 958.8 120 0078 914.0 959.0
121 0079 914.2 959.2 122 007A 914.4 959.4
123 007B 914.6 959.6 124 007C 914.8 959.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 1 Frequency values for P-GSM 900


A30808-X3247-M230-6-7619

2171
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
0 0000 890.0 935.0 1 0001 890.2 935.2
2 0002 890.4 935.4 3 0003 890.6 935.6
4 0004 890.8 935.8 5 0005 891.0 936.0
6 0006 891.2 936.2 7 0007 891.4 936.4
8 0008 891.6 936.6 9 0009 891.8 936.8
10 000A 892.0 937.0 11 000B 892.2 937.2
12 000C 892.4 937.4 13 000D 892.6 937.6
14 000E 892.8 937.8 15 000F 893.0 938.0
16 0010 893.2 938.2 17 0011 893.4 938.4
18 0012 893.6 938.6 19 0013 893.8 938.8
20 0014 894.0 939.0 21 0015 894.2 939.2
22 0016 894.4 939.4 23 0017 894.6 939.6
24 0018 894.8 939.8 25 0019 895.0 940.0
26 001A 895.2 940.2 27 001B 895.4 940.4
28 001C 895.6 940.6 29 001D 895.8 940.8
30 001E 896.0 941.0 31 001F 896.2 941.2
32 0020 896.4 941.4 33 0021 896.6 941.6
34 0022 896.8 941.8 35 0023 897.0 942.0
36 0024 897.2 942.2 37 0025 897.4 942.4
38 0026 897.6 942.6 39 0027 897.8 942.8
40 0028 898.0 943.0 41 0029 898.2 943.2
42 002A 898.4 943.4 43 002B 898.6 943.6
44 002C 898.8 943.8 45 002D 899.0 944.0
46 002E 899.2 944.2 47 002F 899.4 944.4
48 0030 899.6 944.6 49 0031 899.8 944.8
50 0032 900.0 945.0 51 0033 900.2 945.2
52 0034 900.4 945.4 53 0035 900.6 945.6
54 0036 900.8 945.8 55 0037 901.0 946.0
56 0038 901.2 946.2 57 0039 901.4 946.4
58 003A 901.6 946.6 59 003B 901.8 946.8
60 003C 902.0 947.0 61 003D 902.2 947.2
62 003E 902.4 947.4 63 003F 902.6 947.6
Table 2 Frequency values for E-GSM 900 (from 0 to 124)


2172 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
64 0040 902.8 947.8 65 0041 903.0 948.0
66 0042 903.2 948.2 67 0043 903.4 948.4
68 0044 903.6 948.6 69 0045 903.8 948.8
70 0046 904.0 949.0 71 0047 904.2 949.2
72 0048 904.4 949.4 73 0049 904.6 949.6
74 004A 904.8 949.8 75 004B 905.0 950.0
76 004C 905.2 950.2 77 004D 905.4 950.4
78 004E 905.6 950.6 79 004F 905.8 950.8
80 0050 906.0 951.0 81 0051 906.2 951.2
82 0052 906.4 951.4 83 0053 906.6 951.6
84 0054 906.8 951.8 85 0055 907.0 952.0
86 0056 907.2 952.2 87 0057 907.4 952.4
88 0058 907.6 952.6 89 0059 907.8 952.8
90 005A 908.0 953.0 91 005B 908.2 953.2
92 005C 908.4 953.4 93 005D 908.6 953.6
94 005E 908.8 953.8 95 005F 909.0 954.0
96 0060 909.2 954.2 97 0061 909.4 954.4
98 0062 909.6 954.6 99 0063 909.8 954.8
100 0064 910.0 955.0 101 0065 910.2 955.2
102 0066 910.4 955.4 103 0067 910.6 955.6
104 0068 910.8 955.8 105 0069 911.0 956.0
106 006A 911.2 956.2 107 006B 911.4 956.4
108 006C 911.6 956.6 109 006D 911.8 956.8
110 006E 912.0 957.0 111 006F 912.2 957.2
112 0070 912.4 957.4 113 0071 912.6 957.6
114 0072 912.8 957.8 115 0073 913.0 958.0
116 0074 913.2 958.2 117 0075 913.4 958.4
118 0076 913.6 958.6 119 0077 913.8 958.8
120 0078 914.0 959.0 121 0079 914.2 959.2
122 007A 914.4 959.4 123 007B 914.6 959.6
124 007C 914.8 959.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 2 Frequency values for E-GSM 900 (from 0 to 124)


A30808-X3247-M230-6-7619

2173
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
975 03CF 880.2 925.2 976 03D0 880.4 925.4
977 03D1 880.6 925.6 978 03D2 880.8 925.8
979 03D3 881.0 926.0 980 03D4 881.2 926.2
981 03D5 881.4 926.4 982 03D6 881.6 926.6
983 03D7 881.8 926.8 984 03D8 882.0 927.0
985 03D9 882.2 927.2 986 03DA 882.4 927.4
987 03DB 882.6 927.6 988 03DC 882.8 927.8
989 03DD 883.0 928.0 990 03DE 883.2 928.2
991 03DF 883.4 928.4 992 03E0 883.6 928.6
993 03E1 883.8 928.8 994 03E2 884.0 929.0
995 03E3 884.2 929.2 996 03E4 884.4 929.4
997 03E5 884.6 929.6 998 03E6 884.8 929.8
999 03E7 885.0 930.0 1000 03E8 885.2 930.2
1001 03E9 885.4 930.4 1002 03EA 885.6 930.6
1003 03EB 885.8 930.8 1004 03EC 886.0 931.0
1005 03ED 886.2 931.2 1006 03EE 886.4 931.4
1007 03EF 886.6 931.6 1008 03F0 886.8 931.8
1009 03F1 887.0 932.0 1010 03F2 887.2 932.2
1011 03F3 887.4 932.4 1012 03F4 887.6 932.6
1013 03F5 887.8 932.8 1014 03F6 888.0 933.0
1015 03F7 888.2 933.2 1016 03F8 888.4 933.4
1017 03F9 888.6 933.6 1018 03FA 888.8 933.8
1019 03FB 889.0 934.0 1020 03FC 889.2 934.2
1021 03FD 889.4 934.4 1022 03FE 889.6 934.6
1023 03FF 889.8 934.8
Table 3 Frequency values for E-GSM 900 (from 975 to 1023)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
512 0200 1710.2 1805.2 513 0201 1710.4 1805.4
514 0202 1710.6 1805.6 515 0203 1710.8 1805.8
Table 4 Frequency values for DCS 1800


2174 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
516 0204 1711.0 1806.0 517 0205 1711.2 1806.2
518 0206 1711.4 1806.4 519 0207 1711.6 1806.6
520 0208 1711.8 1806.8 521 0209 1712.0 1807.0
522 020A 1712.2 1807.2 523 020B 1712.4 1807.4
524 020C 1712.6 1807.6 525 020D 1712.8 1807.8
526 020E 1713.0 1808.0 527 020F 1713.2 1808.2
528 0210 1713.4 1808.4 529 0211 1713.6 1808.6
530 0212 1713.8 1808.8 531 0213 1714.0 1809.0
532 0214 1714.2 1809.2 533 0215 1714.4 1809.4
534 0216 1714.6 1809.6 535 0217 1714.8 1809.8
536 0218 1715.0 1810.0 537 0219 1715.2 1810.2
538 021A 1715.4 1810.4 539 021B 1715.6 1810.6
540 021C 1715.8 1810.8 541 021D 1716.0 1811.0
542 021E 1716.2 1811.2 543 021F 1716.4 1811.4
544 0220 1716.6 1811.6 545 0221 1716.8 1811.8
546 0222 1717.0 1812.0 547 0223 1717.2 1812.2
548 0224 1717.4 1812.4 549 0225 1717.6 1812.6
550 0226 1717.8 1812.8 551 0227 1718.0 1813.0
552 0228 1718.2 1813.2 553 0229 1718.4 1813.4
554 022A 1718.6 1813.6 555 022B 1718.8 1813.8
556 022C 1719.0 1814.0 557 022D 1719.2 1814.2
558 022E 1719.4 1814.4 559 022F 1719.6 1814.6
560 0230 1719.8 1814.8 561 0231 1720.0 1815.0
562 0232 1720.2 1815.2 563 0233 1720.4 1815.4
564 0234 1720.6 1815.6 565 0235 1720.8 1815.8
566 0236 1721.0 1816.0 567 0237 1721.2 1816.2
568 0238 1721.4 1816.4 569 0239 1721.6 1816.6
570 023A 1721.8 1816.8 571 023B 1722.0 1817.0
572 023C 1722.2 1817.2 573 023D 1722.4 1817.4
574 023E 1722.6 1817.6 575 023F 1722.8 1817.8
576 0240 1723.0 1818.0 577 0241 1723.2 1818.2
578 0242 1723.4 1818.4 579 0243 1723.6 1818.6
580 0244 1723.8 1818.8 581 0245 1724.0 1819.0
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 4 Frequency values for DCS 1800


A30808-X3247-M230-6-7619

2175
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
582 0246 1724.2 1819.2 583 0247 1724.4 1819.4
584 0248 1724.6 1819.6 585 0249 1724.8 1819.8
586 024A 1725.0 1820.0 587 024B 1725.2 1820.2
588 024C 1725.4 1820.4 589 024D 1725.6 1820.6
590 024E 1725.8 1820.8 591 024F 1726.0 1821.0
592 0250 1726.2 1821.2 593 0251 1726.4 1821.4
594 0252 1726.6 1821.6 595 0253 1726.8 1821.8
596 0254 1727.0 1822.0 597 0255 1727.2 1822.2
598 0256 1727.4 1822.4 599 0257 1727.6 1822.6
600 0258 1727.8 1822.8 601 0259 1728.0 1823.0
602 025A 1728.2 1823.2 603 025B 1728.4 1823.4
604 025C 1728.6 1823.6 605 025D 1728.8 1823.8
606 025E 1729.0 1824.0 607 025F 1729.2 1824.2
608 0260 1729.4 1824.4 609 0261 1729.6 1824.6
610 0262 1729.8 1824.8 611 0263 1730.0 1825.0
612 0264 1730.2 1825.2 613 0265 1730.4 1825.4
614 0266 1730.6 1825.6 615 0267 1730.8 1825.8
616 0268 1731.0 1826.0 617 0269 1731.2 1826.2
618 026A 1731.4 1826.4 619 026B 1731.6 1826.6
620 026C 1731.8 1826.8 621 026D 1732.0 1827.0
622 026E 1732.2 1827.2 623 026F 1732.4 1827.4
624 0270 1732.6 1827.6 625 0271 1732.8 1827.8
626 0272 1733.0 1828.0 627 0273 1733.2 1828.2
628 0274 1733.4 1828.4 629 0275 1733.6 1828.6
630 0276 1733.8 1828.8 631 0277 1734.0 1829.0
632 0278 1734.2 1829.2 633 0279 1734.4 1829.4
634 027A 1734.6 1829.6 635 027B 1734.8 1829.8
636 027C 1735.0 1830.0 637 027D 1735.2 1830.2
638 027E 1735.4 1830.4 639 027F 1735.6 1830.6
640 0280 1735.8 1830.8 641 0281 1736.0 1831.0
642 0282 1736.2 1831.2 643 0283 1736.4 1831.4
644 0284 1736.6 1831.6 645 0285 1736.8 1831.8
646 0286 1737.0 1832.0 647 0287 1737.2 1832.2
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 4 Frequency values for DCS 1800


2176 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
648 0288 1737.4 1832.4 649 0289 1737.6 1832.6
650 028A 1737.8 1832.8 651 028B 1738.0 1833.0
652 028C 1738.2 1833.2 653 028D 1738.4 1833.4
654 028E 1738.6 1833.6 655 028F 1738.8 1833.8
656 0290 1739.0 1834.0 657 0291 1739.2 1834.2
658 0292 1739.4 1834.4 659 0293 1739.6 1834.6
660 0294 1739.8 1834.8 661 0295 1740.0 1835.0
662 0296 1740.2 1835.2 663 0297 1740.4 1835.4
664 0298 1740.6 1835.6 665 0299 1740.8 1835.8
666 029A 1741.0 1836.0 667 029B 1741.2 1836.2
668 029C 1741.4 1836.4 669 029D 1741.6 1836.6
670 029E 1741.8 1836.8 671 029F 1742.0 1837.0
672 02A0 1742.2 1837.2 673 02A1 1742.4 1837.4
674 02A2 1742.6 1837.6 675 02A3 1742.8 1837.8
676 02A4 1743.0 1838.0 677 02A5 1743.2 1838.2
678 02A6 1743.4 1838.4 679 02A7 1743.6 1838.6
680 02A8 1743.8 1838.8 681 02A9 1744.0 1839.0
682 02AA 1744.2 1839.2 683 02AB 1744.4 1839.4
684 02AC 1744.6 1839.6 685 02AD 1744.8 1839.8
686 02AE 1745.0 1840.0 687 02AF 1745.2 1840.2
688 02B0 1745.4 1840.4 689 02B1 1745.6 1840.6
690 02B2 1745.8 1840.8 691 02B3 1746.0 1841.0
692 02B4 1746.2 1841.2 693 02B5 1746.4 1841.4
694 02B6 1746.6 1841.6 695 02B7 1746.8 1841.8
696 02B8 1747.0 1842.0 697 02B9 1747.2 1842.2
698 02BA 1747.4 1842.4 699 02BB 1747.6 1842.6
700 02BC 1747.8 1842.8 701 02BD 1748.0 1843.0
702 02BE 1748.2 1843.2 703 02BF 1748.4 1843.4
704 02C0 1748.6 1843.6 705 02C1 1748.8 1843.8
706 02C2 1749.0 1844.0 707 02C3 1749.2 1844.2
708 02C4 1749.4 1844.4 709 02C5 1749.6 1844.6
710 02C6 1749.8 1844.8 711 02C7 1750.0 1845.0
712 02C8 1750.2 1845.2 713 02C9 1750.4 1845.4
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 4 Frequency values for DCS 1800


A30808-X3247-M230-6-7619

2177
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
714 02CA 1750.6 1845.6 715 02CB 1750.8 1845.8
716 02CC 1751.0 1846.0 717 02CD 1751.2 1846.2
718 02CE 1751.4 1846.4 719 02CF 1751.6 1846.6
720 02D0 1751.8 1846.8 721 02D1 1752.0 1847.0
722 02D2 1752.2 1847.2 723 02D3 1752.4 1847.4
724 02D4 1752.6 1847.6 725 02D5 1752.8 1847.8
726 02D6 1753.0 1848.0 727 02D7 1753.2 1848.2
728 02D8 1753.4 1848.4 729 02D9 1753.6 1848.6
730 02DA 1753.8 1848.8 731 02DB 1754.0 1849.0
732 02DC 1754.2 1849.2 733 02DD 1754.4 1849.4
734 02DE 1754.6 1849.6 735 02DF 1754.8 1849.8
736 02E0 1755.0 1850.0 737 02E1 1755.2 1850.2
738 02E2 1755.4 1850.4 739 02E3 1755.6 1850.6
740 02E4 1755.8 1850.8 741 02E5 1756.0 1851.0
742 02E6 1756.2 1851.2 743 02E7 1756.4 1851.4
744 02E8 1756.6 1851.6 745 02E9 1756.8 1851.8
746 02EA 1757.0 1852.0 747 02EB 1757.2 1852.2
748 02EC 1757.4 1852.4 749 02ED 1757.6 1852.6
750 02EE 1757.8 1852.8 751 02EF 1758.0 1853.0
752 02F0 1758.2 1853.2 753 02F1 1758.4 1853.4
754 02F2 1758.6 1853.6 755 02F3 1758.8 1853.8
756 02F4 1759.0 1854.0 757 02F5 1759.2 1854.2
758 02F6 1759.4 1854.4 759 02F7 1759.6 1854.6
760 02F8 1759.8 1854.8 761 02F9 1760.0 1855.0
762 02FA 1760.2 1855.2 763 02FB 1760.4 1855.4
764 02FC 1760.6 1855.6 765 02FD 1760.8 1855.8
766 02FE 1761.0 1856.0 767 02FF 1761.2 1856.2
768 0300 1761.4 1856.4 769 0301 1761.6 1856.6
770 0302 1761.8 1856.8 771 0303 1762.0 1857.0
772 0304 1762.2 1857.2 773 0305 1762.4 1857.4
774 0306 1762.6 1857.6 775 0307 1762.8 1857.8
776 0308 1763.0 1858.0 777 0309 1763.2 1858.2
778 030A 1763.4 1858.4 779 030B 1763.6 1858.6
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 4 Frequency values for DCS 1800


2178 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
780 030C 1763.8 1858.8 781 030D 1764.0 1859.0
782 030E 1764.2 1859.2 783 030F 1764.4 1859.4
784 0310 1764.6 1859.6 785 0311 1764.8 1859.8
786 0312 1765.0 1860.0 787 0313 1765.2 1860.2
788 0314 1765.4 1860.4 789 0315 1765.6 1860.6
790 0316 1765.8 1860.8 791 0317 1766.0 1861.0
792 0318 1766.2 1861.2 793 0319 1766.4 1861.4
794 031A 1766.6 1861.6 795 031B 1766.8 1861.8
796 031C 1767.0 1862.0 797 031D 1767.2 1862.2
798 031E 1767.4 1862.4 799 031F 1767.6 1862.6
800 0320 1767.8 1862.8 801 0321 1768.0 1863.0
802 0322 1768.2 1863.2 803 0323 1768.4 1863.4
804 0324 1768.6 1863.6 805 0325 1768.8 1863.8
806 0326 1769.0 1864.0 807 0327 1769.2 1864.2
808 0328 1769.4 1864.4 809 0329 1769.6 1864.6
810 032A 1769.8 1864.8 811 032B 1770.0 1865.0
812 032C 1770.2 1865.2 813 032D 1770.4 1865.4
814 032E 1770.6 1865.6 815 032F 1770.8 1865.8
816 0330 1771.0 1866.0 817 0331 1771.2 1866.2
818 0332 1771.4 1866.4 819 0333 1771.6 1866.6
820 0334 1771.8 1866.8 821 0335 1772.0 1867.0
822 0336 1772.2 1867.2 823 0337 1772.4 1867.4
824 0338 1772.6 1867.6 825 0339 1772.8 1867.8
826 033A 1773.0 1868.0 827 033B 1773.2 1868.2
828 033C 1773.4 1868.4 829 033D 1773.6 1868.6
830 033E 1773.8 1868.8 831 033F 1774.0 1869.0
832 0340 1774.2 1869.2 833 0341 1774.4 1869.4
834 0342 1774.6 1869.6 835 0343 1774.8 1869.8
836 0344 1775.0 1870.0 837 0345 1775.2 1870.2
838 0346 1775.4 1870.4 839 0347 1775.6 1870.6
840 0348 1775.8 1870.8 841 0349 1776.0 1871.0
842 034A 1776.2 1871.2 843 034B 1776.4 1871.4
844 034C 1776.6 1871.6 845 034D 1776.8 1871.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 4 Frequency values for DCS 1800


A30808-X3247-M230-6-7619

2179
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
846 034E 1777.0 1872.0 847 034F 1777.2 1872.2
848 0350 1777.4 1872.4 849 0351 1777.6 1872.6
850 0352 1777.8 1872.8 851 0353 1778.0 1873.0
852 0354 1778.2 1873.2 853 0355 1778.4 1873.4
854 0356 1778.6 1873.6 855 0357 1778.8 1873.8
856 0358 1779.0 1874.0 857 0359 1779.2 1874.2
858 035A 1779.4 1874.4 859 035B 1779.6 1874.6
860 035C 1779.8 1874.8 861 035D 1780.0 1875.0
862 035E 1780.2 1875.2 863 035F 1780.4 1875.4
864 0360 1780.6 1875.6 865 0361 1780.8 1875.8
866 0362 1781.0 1876.0 867 0363 1781.2 1876.2
868 0364 1781.4 1876.4 869 0365 1781.6 1876.6
870 0366 1781.8 1876.8 871 0367 1782.0 1877.0
872 0368 1782.2 1877.2 873 0369 1782.4 1877.4
874 036A 1782.6 1877.6 875 036B 1782.8 1877.8
876 036C 1783.0 1878.0 877 036D 1783.2 1878.2
878 036E 1783.4 1878.4 879 036F 1783.6 1878.6
880 0370 1783.8 1878.8 881 0371 1784.0 1879.0
882 0372 1784.2 1879.2 883 0373 1784.4 1879.4
884 0374 1784.6 1879.6 885 0375 1784.8 1879.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
955 03BB 876.2 921.2 956 03BC 876.4 921.4
957 03BD 876.6 921.6 958 03BE 876.8 921.8
959 03BF 877.0 922.0 960 03C0 877.2 922.2
961 03C1 877.4 922.4 962 03C2 877.6 922.6
963 03C3 877.8 922.8 964 03C4 878.0 923.0
965 03C5 878.2 923.2 966 03C6 878.4 923.4
967 03C7 878.6 923.6 968 03C8 878.8 923.8
969 03C9 879.0 924.0 970 03CA 879.2 924.2
971 03CB 879.4 924.4 972 03CC 879.6 924.6
Table 5 Frequency values for GSM-R
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 4 Frequency values for DCS 1800


2180 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
973 03CD 879.8 924.8 974 03CE 880.0 925.0
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
512 0200 1850.2 1930.2 513 0201 1850.4 1930.4
514 0202 1850.6 1930.6 515 0203 1850.8 1930.8
516 0204 1851.0 1931.0 517 0205 1851.2 1931.2
518 0206 1851.4 1931.4 519 0207 1851.6 1931.6
520 0208 1851.8 1931.8 521 0209 1852.0 1932.0
522 020A 1852.2 1932.2 523 020B 1852.4 1932.4
524 020C 1852.6 1932.6 525 020D 1852.8 1932.8
526 020E 1853.0 1933.0 527 020F 1853.2 1933.2
528 0210 1853.4 1933.4 529 0211 1853.6 1933.6
530 0212 1853.8 1933.8 531 0213 1854.0 1934.0
532 0214 1854.2 1934.2 533 0215 1854.4 1934.4
534 0216 1854.6 1934.6 535 0217 1854.8 1934.8
536 0218 1855.0 1935.0 537 0219 1855.2 1935.2
538 021A 1855.4 1935.4 539 021B 1855.6 1935.6
540 021C 1855.8 1935.8 541 021D 1856.0 1936.0
542 021E 1856.2 1936.2 543 021F 1856.4 1936.4
544 0220 1856.6 1936.6 545 0221 1856.8 1936.8
546 0222 1857.0 1937.0 547 0223 1857.2 1937.2
548 0224 1857.4 1937.4 549 0225 1857.6 1937.6
550 0226 1857.8 1937.8 551 0227 1858.0 1938.0
552 0228 1858.2 1938.2 553 0229 1858.4 1938.4
554 022A 1858.6 1938.6 555 022B 1858.8 1938.8
556 022C 1859.0 1939.0 557 022D 1859.2 1939.2
558 022E 1859.4 1939.4 559 022F 1859.6 1939.6
560 0230 1859.8 1939.8 561 0231 1860.0 1940.0
562 0232 1860.2 1940.2 563 0233 1860.4 1940.4
564 0234 1860.6 1940.6 565 0235 1860.8 1940.8
566 0236 1861.0 1941.0 567 0237 1861.2 1941.2
Table 6 Frequency values for PCS 1900
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 5 Frequency values for GSM-R


A30808-X3247-M230-6-7619

2181
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
568 0238 1861.4 1941.4 569 0239 1861.6 1941.6
570 023A 1861.8 1941.8 571 023B 1862.0 1942.0
572 023C 1862.2 1942.2 573 023D 1862.4 1942.4
574 023E 1862.6 1942.6 575 023F 1862.8 1942.8
576 0240 1863.0 1943.0 577 0241 1863.2 1943.2
578 0242 1863.4 1943.4 579 0243 1863.6 1943.6
580 0244 1863.8 1943.8 581 0245 1864.0 1944.0
582 0246 1864.2 1944.2 583 0247 1864.4 1944.4
584 0248 1864.6 1944.6 585 0249 1864.8 1944.8
586 024A 1865.0 1945.0 587 024B 1865.2 1945.2
588 024C 1865.4 1945.4 589 024D 1865.6 1945.6
590 024E 1865.8 1945.8 591 024F 1866.0 1946.0
592 0250 1866.2 1946.2 593 0251 1866.4 1946.4
594 0252 1866.6 1946.6 595 0253 1866.8 1946.8
596 0254 1867.0 1947.0 597 0255 1867.2 1947.2
598 0256 1867.4 1947.4 599 0257 1867.6 1947.6
600 0258 1867.8 1947.8 601 0259 1868.0 1948.0
602 025A 1868.2 1948.2 603 025B 1868.4 1948.4
604 025C 1868.6 1948.6 605 025D 1868.8 1948.8
606 025E 1869.0 1949.0 607 025F 1869.2 1949.2
608 0260 1869.4 1949.4 609 0261 1869.6 1949.6
610 0262 1869.8 1949.8 611 0263 1870.0 1950.0
612 0264 1870.2 1950.2 613 0265 1870.4 1950.4
614 0266 1870.6 1950.6 615 0267 1870.8 1950.8
616 0268 1871.0 1951.0 617 0269 1871.2 1951.2
618 026A 1871.4 1951.4 619 026B 1871.6 1951.6
620 026C 1871.8 1951.8 621 026D 1872.0 1952.0
622 026E 1872.2 1952.2 623 026F 1872.4 1952.4
624 0270 1872.6 1952.6 625 0271 1872.8 1952.8
626 0272 1873.0 1953.0 627 0273 1873.2 1953.2
628 0274 1873.4 1953.4 629 0275 1873.6 1953.6
630 0276 1873.8 1953.8 631 0277 1874.0 1954.0
632 0278 1874.2 1954.2 633 0279 1874.4 1954.4
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 6 Frequency values for PCS 1900


2182 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
634 027A 1874.6 1954.6 635 027B 1874.8 1954.8
636 027C 1875.0 1955.0 637 027D 1875.2 1955.2
638 027E 1875.4 1955.4 639 027F 1875.6 1955.6
640 0280 1875.8 1955.8 641 0281 1876.0 1956.0
642 0282 1876.2 1956.2 643 0283 1876.4 1956.4
644 0284 1876.6 1956.6 645 0285 1876.8 1956.8
646 0286 1877.0 1957.0 647 0287 1877.2 1957.2
648 0288 1877.4 1957.4 649 0289 1877.6 1957.6
650 028A 1877.8 1957.8 651 028B 1878.0 1958.0
652 028C 1878.2 1958.2 653 028D 1878.4 1958.4
654 028E 1878.6 1958.6 655 028F 1878.8 1958.8
656 0290 1879.0 1959.0 657 0291 1879.2 1959.2
658 0292 1879.4 1959.4 659 0293 1879.6 1959.6
660 0294 1879.8 1959.8 661 0295 1880.0 1960.0
662 0296 1880.2 1960.2 663 0297 1880.4 1960.4
664 0298 1880.6 1960.6 665 0299 1880.8 1960.8
666 029A 1881.0 1961.0 667 029B 1881.2 1961.2
668 029C 1881.4 1961.4 669 029D 1881.6 1961.6
670 029E 1881.8 1961.8 671 029F 1882.0 1962.0
672 02A0 1882.2 1962.2 673 02A1 1882.4 1962.4
674 02A2 1882.6 1962.6 675 02A3 1882.8 1962.8
676 02A4 1883.0 1963.0 677 02A5 1883.2 1963.2
678 02A6 1883.4 1963.4 679 02A7 1883.6 1963.6
680 02A8 1883.8 1963.8 681 02A9 1884.0 1964.0
682 02AA 1884.2 1964.2 683 02AB 1884.4 1964.4
684 02AC 1884.6 1964.6 685 02AD 1884.8 1964.8
686 02AE 1885.0 1965.0 687 02AF 1885.2 1965.2
688 02B0 1885.4 1965.4 689 02B1 1885.6 1965.6
690 02B2 1885.8 1965.8 691 02B3 1886.0 1966.0
692 02B4 1886.2 1966.2 693 02B5 1886.4 1966.4
694 02B6 1886.6 1966.6 695 02B7 1886.8 1966.8
696 02B8 1887.0 1967.0 697 02B9 1887.2 1967.2
698 02BA 1887.4 1967.4 699 02BB 1887.6 1967.6
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 6 Frequency values for PCS 1900


A30808-X3247-M230-6-7619

2183
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
700 02BC 1887.8 1967.8 701 02BD 1888.0 1968.0
702 02BE 1888.2 1968.2 703 02BF 1888.4 1968.4
704 02C0 1888.6 1968.6 705 02C1 1888.8 1968.8
706 02C2 1889.0 1969.0 707 02C3 1889.2 1969.2
708 02C4 1889.4 1969.4 709 02C5 1889.6 1969.6
710 02C6 1889.8 1969.8 711 02C7 1890.0 1970.0
712 02C8 1890.2 1970.2 713 02C9 1890.4 1970.4
714 02CA 1890.6 1970.6 715 02CB 1890.8 1970.8
716 02CC 1891.0 1971.0 717 02CD 1891.2 1971.2
718 02CE 1891.4 1971.4 719 02CF 1891.6 1971.6
720 02D0 1891.8 1971.8 721 02D1 1892.0 1972.0
722 02D2 1892.2 1972.2 723 02D3 1892.4 1972.4
724 02D4 1892.6 1972.6 725 02D5 1892.8 1972.8
726 02D6 1893.0 1973.0 727 02D7 1893.2 1973.2
728 02D8 1893.4 1973.4 729 02D9 1893.6 1973.6
730 02DA 1893.8 1973.8 731 02DB 1894.0 1974.0
732 02DC 1894.2 1974.2 733 02DD 1894.4 1974.4
734 02DE 1894.6 1974.6 735 02DF 1894.8 1974.8
736 02E0 1895.0 1975.0 737 02E1 1895.2 1975.2
738 02E2 1895.4 1975.4 739 02E3 1895.6 1975.6
740 02E4 1895.8 1975.8 741 02E5 1896.0 1976.0
742 02E6 1896.2 1976.2 743 02E7 1896.4 1976.4
744 02E8 1896.6 1976.6 745 02E9 1896.8 1976.8
746 02EA 1897.0 1977.0 747 02EB 1897.2 1977.2
748 02EC 1897.4 1977.4 749 02ED 1897.6 1977.6
750 02EE 1897.8 1977.8 751 02EF 1898.0 1978.0
752 02F0 1898.2 1978.2 753 02F1 1898.4 1978.4
754 02F2 1898.6 1978.6 755 02F3 1898.8 1978.8
756 02F4 1899.0 1979.0 757 02F5 1899.2 1979.2
758 02F6 1899.4 1979.4 759 02F7 1899.6 1979.6
760 02F8 1899.8 1979.8 761 02F9 1900.0 1980.0
762 02FA 1900.2 1980.2 763 02FB 1900.4 1980.4
764 02FC 1900.6 1980.6 765 02FD 1900.8 1980.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 6 Frequency values for PCS 1900


2184 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
766 02FE 1901.0 1981.0 767 02FF 1901.2 1981.2
768 0300 1901.4 1981.4 769 0301 1901.6 1981.6
770 0302 1901.8 1981.8 771 0303 1902.0 1982.0
772 0304 1902.2 1982.2 773 0305 1902.4 1982.4
774 0306 1902.6 1982.6 775 0307 1902.8 1982.8
776 0308 1903.0 1983.0 777 0309 1903.2 1983.2
778 030A 1903.4 1983.4 779 030B 1903.6 1983.6
780 030C 1903.8 1983.8 781 030D 1904.0 1984.0
782 030E 1904.2 1984.2 783 030F 1904.4 1984.4
784 0310 1904.6 1984.6 785 0311 1904.8 1984.8
786 0312 1905.0 1985.0 787 0313 1905.2 1985.2
788 0314 1905.4 1985.4 789 0315 1905.6 1985.6
790 0316 1905.8 1985.8 791 0317 1906.0 1986.0
792 0318 1906.2 1986.2 793 0319 1906.4 1986.4
794 031A 1906.6 1986.6 795 031B 1906.8 1986.8
796 031C 1907.0 1987.0 797 031D 1907.2 1987.2
798 031E 1907.4 1987.4 799 031F 1907.6 1987.6
800 0320 1907.8 1987.8 801 0321 1908.0 1988.0
802 0322 1908.2 1988.2 803 0323 1908.4 1988.4
804 0324 1908.6 1988.6 805 0325 1908.8 1988.8
806 0326 1909.0 1989.0 807 0327 1909.2 1989.2
808 0328 1909.4 1989.4 809 0329 1909.6 1989.6
810 032A 1909.8 1989.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
128 0080 824.2 869.2 129 0081 824.4 869.4
130 0082 824.6 869.6 131 0083 824.8 869.8
132 0084 825.0 870.0 133 0085 825.2 870.2
134 0086 825.4 870.4 135 0087 825.6 870.6
136 0088 825.8 870.8 137 0089 826.0 871.0
138 008A 826.2 871.2 139 008B 826.4 871.4
Table 7 Frequency values for GSM 850
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 6 Frequency values for PCS 1900


A30808-X3247-M230-6-7619

2185
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
140 008C 826.6 871.6 141 008D 826.8 871.8
142 008E 827.0 872.0 143 008F 827.2 872.2
144 0090 827.4 872.4 145 0091 827.6 872.6
146 0092 827.8 872.8 147 0093 828.0 873.0
148 0094 828.2 873.2 149 0095 828.4 873.4
150 0096 828.6 873.6 151 0097 828.8 873.8
152 0098 829.0 874.0 153 0099 829.2 874.2
154 009A 829.4 874.4 155 009B 829.6 874.6
156 009C 829.8 874.8 157 009D 830.0 875.0
158 009E 830.2 875.2 159 009F 830.4 875.4
160 00A0 830.6 875.6 161 00A1 830.8 875.8
162 00A2 831.0 876.0 163 00A3 831.2 876.2
164 00A4 831.4 876.4 165 00A5 831.6 876.6
166 00A6 831.8 876.8 167 00A7 832.0 877.0
168 00A8 832.2 877.2 169 00A9 832.4 877.4
170 00AA 832.6 877.6 171 00AB 832.8 877.8
172 00AC 833.0 878.0 173 00AD 833.2 878.2
174 00AE 833.4 878.4 175 00AF 833.6 878.6
176 00B0 833.8 878.8 177 00B1 834.0 879.0
178 00B2 834.2 879.2 179 00B3 834.4 879.4
180 00B4 834.6 879.6 181 00B5 834.8 879.8
182 00B6 835.0 880.0 183 00B7 835.2 880.2
184 00B8 835.4 880.4 185 00B9 835.6 880.6
186 00BA 835.8 880.8 187 00BB 836.0 881.0
188 00BC 836.2 881.2 189 00BD 836.4 881.4
190 00BE 836.6 881.6 191 00BF 836.8 881.8
192 00C0 837.0 882.0 193 00C1 837.2 882.2
194 00C2 837.4 882.4 195 00C3 837.6 882.6
196 00C4 837.8 882.8 197 00C5 838.0 883.0
198 00C6 838.2 883.2 199 00C7 838.4 883.4
200 00C8 838.6 883.6 201 00C9 838.8 883.8
202 00CA 839.0 884.0 203 00CB 839.2 884.2
204 00CC 839.4 884.4 205 00CD 839.6 884.6
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 7 Frequency values for GSM 850


2186 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.2 Special Parameter Values - Group 2
Group 2
HOLTHLVDL: hoLowerThresholdLevDL
HOLTHLVUL: hoLowerThresholdLevUL
HOTDLINT: hoThresholdLevDLintra
HOTULINT: hoThresholdLevULintra
LOWTLEVD: pcLowerThresholdLevDL
LOWTLEVU: pcLowerThresholdLevUL
UPTLEVD: pcUpperThresholdLevDL
UPTLEVU: pcUpperThresholdLevUL
206 00CE 839.8 884.8 207 00CF 840.0 885.0
208 00D0 840.2 885.2 209 00D1 840.4 885.4
210 00D2 840.6 885.6 211 00D3 840.8 885.8
212 00D4 841.0 886.0 213 00D5 841.2 886.2
214 00D6 841.4 886.4 215 00D7 841.6 886.6
216 00D8 841.8 886.8 217 00D9 842.0 887.0
218 00DA 842.2 887.2 219 00DB 842.4 887.4
220 00DC 842.6 887.6 221 00DD 842.8 887.8
222 00DE 843.0 888.0 223 00DF 843.2 888.2
224 00E0 843.4 888.4 225 00E1 843.6 888.6
226 00E2 843.8 888.8 227 00E3 844.0 889.0
228 00E4 844.2 889.2 229 00E5 844.4 889.4
230 00E6 844.6 889.6 231 00E7 844.8 889.8
232 00E8 845.0 890.0 233 00E9 845.2 890.2
234 00EA 845.4 890.4 235 00EB 845.6 890.6
236 00EC 845.8 890.8 237 00ED 846.0 891.0
238 00EE 846.2 891.2 239 00EF 846.4 891.4
240 00F0 846.6 891.6 241 00F1 846.8 891.8
242 00F2 847.0 892.0 243 00F3 847.2 892.2
244 00F4 847.4 892.4 245 00F5 847.6 892.6
246 00F6 847.8 892.8 247 00F7 848.0 893.0
248 00F8 848.2 893.2 249 00F9 848.4 893.4
250 00FA 848.6 893.6 251 00FB 848.8 893.8
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Dec. Hex. Fu
(MHz)
Fd
(MHz)
Table 7 Frequency values for GSM 850


A30808-X3247-M230-6-7619

2187
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
RXLEVMIN: rxLevMinCell
Range: 0-63 dBr (Table 8)
Dec. dBm value dBm range Dec. dBm value dBm range
0 -110 -|...<= -110 32 -78 -79<...<=-78
1 -109 -110<...<= -109 33 -77 -78<...<=-77
2 -108 -109<...<= -108 34 -76 -77<...<=-76
3 -107 -108<...<= -107 35 -75 -76<...<=-75
4 -106 -107<...<= -106 36 -74 -75<...<=-74
5 -105 -106<...<= -105 37 -73 -74<...<=-73
6 -104 -105<...<= -104 38 -72 -73<...<=-72
7 -103 -104<...<= -103 39 -71 -72<...<=-71
8 -102 -103<...<= -102 40 -70 -71<...<=-70
9 -101 -102<...<= -101 41 -69 -70<...<=-69
10 -100 -101<...<= -100 42 -68 -69<...<=-68
11 -99 -100<...<= -99 43 -67 -68<...<=-67
12 -98 -99<...<= -98 44 -66 -67<...<=-66
13 -97 -98<...<= -97 45 -65 -66<...<=-65
14 -96 -97<...<= -96 46 -64 -65<...<=-64
15 -95 -96<...<= -95 47 -63 -64<...<=-63
16 -94 -95<...<= -94 48 -62 -63<...<=-62
17 -93 -94<...<= -93 49 -61 -62<...<=-61
18 -92 -93<...<= -92 50 -60 -61<...<=-60
19 -91 -92<...<= -91 51 -59 -60<...<=-59
20 -90 -91<...<= -90 52 -58 -59<...<=-58
21 -89 -90<...<= -89 53 -57 -58<...<=-57
22 -88 -89<...<= -88 54 -56 -57<...<=-56
23 -87 -88<...<= -87 55 -55 -56<...<=-55
24 -86 -87<...<= -86 56 -54 -55<...<=-54
25 -85 -86<...<= -85 57 -53 -54<...<=-53
26 -84 -85<...<= -84 58 -52 -53<...<=-52
27 -83 -84<...<= -83 59 -51 -52<...<=-51
28 -82 -83<...<= -82 60 -50 -51<...<=-50
29 -81 -82<...<= -81 61 -49 -50<...<=-49
30 -80 -81<...<= -80 62 -48 -49<...<=-48
Table 8 Values for received signal threshold


2188 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.3 Special Parameter Values - Group 3
Group 3
Handover thresholds:
HOLTHQUDL: hoLowerThresholdQualDL (range: 0..7)
HOLTHQUUL: hoLowerThresholdQualUL (range: 0..7)
LOWTQUAD: pcLowerThresholdQualDL (range: 0..7)
LOWTQUAU: pcLowerThresholdQualUL (range: 0..7)
UPTQUAD: pcUpperThresholdQualDL (range: 0..7)
UPTQUAU: pcUpperThresholdQualUL (range: 0..7)
Configuration rules for service independent attributes:
HOLTHQUDL > LOWTQUAD > UPTQUAD
HOLTHQUUL > LOWTQUAU > UPTQUAU
Configuration rules for SGXHOPAR and/or the SGXPCPAR (X = 1..10) service
dependent attributes:
When the service dependent SGXHOPAR and/or the SGXPCPAR attributes are
different from NULL, the configuration rules above apply to the fields of the SGXHOPAR
and SGXPCPAR attributes. See in Group 7 description of Service Groups and service
dependent attributes.
Example 1: if SG3HOPAR is different from NULL value and SG3PCPAR attribute is
equal to NULL value:
SG3HOPAR.hoLowerThresholdQualDL > LOWTQUAD > UPTQUAD
SG3HOPAR.hoLowerThresholdQualUL > LOWTQUAU > UPTQUAU
Example 2: if SG5HOPAR is equal to NULL value and SG5PCPAR attribute is different
from NULL value:
HOLTHQUDL > SG5PCPAR.pcLowerThresholdQualDL >
> SG5PCPAR.pcUpperThresholdQualDL
HOLTHQUUL > SG5PCPAR.pcLowerThresholdQualUL >
> SG5PCPAR.pcUpperThresholdQualUL
Example 3: if both SG10HOPAR and SG10PCPAR are different from NULL value:
SG10HOPAR.hoLowerThresholdQualDL >
> SG10PCPAR.pcLowerThresholdQualDL
SG10PCPAR.pcLowerThresholdQualDL >
> SG10PCPAR.pcUpperThresholdQualDL
SG10HOPAR.hoLowerThresholdQualUL >
> SG10PCPAR.pcLowerThresholdQualUL
SG10PCPAR.pcLowerThresholdQualUL >
> SG10PCPAR.pcUpperThresholdQualUL
Rate 14.4 kbit/s, 9.6 kbit/s upgrade/downgrade thresholds:
RUGRDL: rateUpgradeDownlink (range: 0..5)
RUGRUL: rateUpgradeUplink (range: 0..5)
31 -79 -80<...<= -79 63 -47 -48<...+|
Dec. dBm value dBm range Dec. dBm value dBm range
Table 8 Values for received signal threshold


A30808-X3247-M230-6-7619

2189
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
RDGRDL: rateDowngradeDownlink (range: 1..6)
RDGRUL: rateDowngradeUplink (range: 1..6)
RHOLTQDL: rateHoLowerThresholdQualDownlink (range: 2..7)
RHOLTQUL: rateHoLowerThresholdQualUplink (range: 2..7)
Configuration rules for service independent attributes:
RUGRDL < RDGRDL < RHOLTQDL
RUGRUL < RDGRUL < RHOLTQUL
Configuration rules for SGXHOPAR (X = 7..10) service dependent attributes:
When the service dependent SGXHOPAR is different from NULL, the configuration
rules above apply to the fields of the SGXHOPAR attribute. See in Group 7 description
of Service Groups and service dependent attributes.
Example: if SG7HOPAR is different from NULL value:
RUGRDL > RDGRDL > SG7HOPAR.rateHoLowerThresholdQualDL
RUGRUL > RDGRUL > SG7HOPAR.rateHoLowerThresholdQualUL.
Threshold Signal Quality Range for Bit Error Rate
00 BER < 0,2 %
01 0,2 % < BER < 0,4 %
02 0,4 % < BER < 0,8 %
03 0,8 % < BER < 1,6 %
04 1,6 % < BER < 3,2 %
05 3,2 % < BER < 6,4 %
06 6,4 % < BER < 12,8 %
07 12,8 % < BER
Table 9 Relationship between Signal Quality and BER


2190 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.4 Special Parameter Values - Group 4
Group 4
MSTXPMAXGSM: msTxPwrMaxGsm
MSTXPMAXDCS: msTxPwrMaxDcs
MSTXPMAXPCS: msTxPwrMaxPcs
MSTXPMAXUMTS: msTxPwrMaxUmts
Range: 2-15 for GSM 900, GSM 850 and R-GSM (Table 10)
0-15 for DCS 1800 (Table 11)
0-15, 30-31 for PCS 1900 (Table 12)
0-19 for UMTS (Table 13)
Dec. (Hex.) Power Level
02 (02) 39 dBm
03 (03) 37 dBm
04 (04) 35 dBm
05 (05) 33 dBm
06 (06) 31 dBm
07 (07) 29 dBm
08 (08) 27 dBm
09 (09) 25 dBm
10 (0A) 23 dBm
11 (0B) 21 dBm
12 (0C) 19 dBm
13 (0D) 17 dBm
14 (0E) 15 dBm
15 (0F) 13 dBm
Table 10 Values for GSM and R-GSM
Dec. (Hex.) Power Level
00 (00) 30 dBm
01 (01) 28 dBm
02 (02) 26 dBm
03 (03) 24 dBm
04 (04) 22 dBm
Table 11 Values for DCS 1800


A30808-X3247-M230-6-7619

2191
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
05 (05) 20 dBm
06 (06) 18 dBm
07 (07) 16 dBm
08 (08) 14 dBm
09 (09) 12 dBm
10 (0A) 10 dBm
11 (0B) 08 dBm
12 (0C) 06 dBm
13 (0D) 04 dBm
14 (0E) 02 dBm
15 (0F) 00 dBm
Dec. (Hex.) Power Level
00 (00) 30 dBm
01 (01) 28 dBm
02 (02) 26 dBm
03 (03) 24 dBm
04 (04) 22 dBm
05 (05) 20 dBm
06 (06) 18 dBm
07 (07) 16 dBm
08 (08) 14 dBm
09 (09) 12 dBm
10 (0A) 10 dBm
11 (0B) 08 dBm
12 (0C) 06 dBm
13 (0D) 04 dBm
14 (0E) 02 dBm
15 (0F) 00 dBm
30 (1E) 33 dBm
31 (1F) 32 dBm
Table 12 Values for PCS 1900
Dec. (Hex.) Power Level
Table 11 Values for DCS 1800


2192 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
Dec. (Hex.) Power Level
00 (00) 43 dBm
01 (01) 41 dBm
02 (02) 39 dBm
03 (03) 37 dBm
04 (04) 35 dBm
05 (05) 33 dBm
06 (06) 31 dBm
07 (07) 29 dBm
08 (08) 27 dBm
09 (09) 25 dBm
10 (0A) 23 dBm
11 (0B) 21 dBm
12 (0C) 19 dBm
13 (0D) 17 dBm
14 (0E) 15 dBm
15 (0F) 13 dBm
16 (10) 11 dBm
17 (11) 9 dBm
18 (12) 7 dBm
19 (13) 5 dBm
Table 13 Values for UMTS


A30808-X3247-M230-6-7619

2193
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
6.5 Special Parameter Values - Group 5
Group 5
Table 14 shows the circuit pool number (1 to 48) with the corresponding supported
channels and speech coding algorithms.
The following O&M parameters are used to enable and define the pooling feature:
EPOOL: enablePooling (BSC object)
DEFPOOLTYP: defPoolType (PCMA object)
POOLTYP: poolType (TSLA object)
Pool Number
(POOL_<n>)
Supported Channels and
Speech Coding Algorithms
Circuit pool n. 1 FR speech version 1
FR data (12, 6, 3.6 kbit/s)
Circuit pool n. 2 HR speech version 1
HR data (6, 3.6 kbit/s)
Circuit pool n. 3 FR speech version 1
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
Circuit pool n. 4 FR speech version 2
FR data (12, 6, 3.6 kbit/s)
Circuit pool n. 5 FR speech version 1
FR speech version 2
FR data (12, 6, 3.6 kbit/s)
Circuit pool n. 6 FR speech version 2
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
Circuit pool n. 7 FR speech version 1
FR speech version 2
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
Circuit pool n. 8 HSCSD max 2 x FR data (12, 6 kbit/s)
Circuit pool n. 9 FR data (12, 6, 3.6 kbit/s)
HR data (6, 3.6 kbit/s)
HSCSD max 2 x FR data (12, 6 kbit/s)
Circuit pool n. 10 FR speech version 1
FR speech version 2
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
HSCSD max 2 x FR data (12, 6 kbit/s)
Table 14 Circuit Pool Coding


2194 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
Circuit pool n. 11 HSCSD max 4 x FR data (12, 6 kbit/s)
Circuit pool n. 12 FR data (12, 6, 3.6 kbit/s)
HR data (6, 3.6 kbit/s)
HSCSD max 4 x FR data (12, 6 kbit/s)
Circuit pool n. 13 FR speech version 1
FR speech version 2
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
HSCSD max 4 x FR data (12, 6 kbit/s)
Circuit pool n. 14
(not used)
HSCSD max 6 x FR data (12, 6 kbit/s)
EDGE max 2 x FR data (32.0 kbit/s)
Circuit pool n. 15 FR data (14.5 kbit/s)
Circuit pool n. 16 HSCSD max 2 x FR data (14.5 kbit/s)
EDGE FR data (29.0 kbit/s)
Circuit pool n. 17 HSCSD max 4 x FR data (14.5 kbit/s)
EDGE max 2 x FR data (29.0 kbit/s)
EDGE FR data (43.5 kbit/s)
Circuit pool n. 18 FR data (14.5, 12, 6, 3.6 kbit/s)
HR data (6, 3.6 kbit/s)
HSCSD max 2 x FR data (14.5, 12, 6 kbit/s)
EDGE FR data (29.0 kbit/s)
Circuit pool n. 19 FR data (14.5, 12, 6, 3.6 kbit/s)
HR data (6, 3.6 kbit/s)
HSCSD max 4 x FR data (14.5, 12, 6 kbit/s)
EDGE max 2 x FR data (29.0 kbit/s)
EDGE FR data (43.5 kbit/s)
Circuit pool n. 20 FR speech version 1
FR speech version 2
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
Circuit pool n. 21 FR speech version 1
FR speech version 2
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
HSCSD max 2 x FR data (14.5, 12, 6 kbit/s)
EDGE FR data (29.0 kbit/s)
Pool Number
(POOL_<n>)
Supported Channels and
Speech Coding Algorithms
Table 14 Circuit Pool Coding


A30808-X3247-M230-6-7619

2195
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
Circuit pool n. 22 FR speech version 1
FR speech version 2
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
HSCSD max 4 x FR data (14.5, 12, 6 kbit/s)
EDGE max 2 x FR data (29.0 kbit/s)
EDGE FR data (43.5 kbit/s)
Circuit pool n. 23 Speech Version 3
Circuit pool n. 24 FR speech version 3
FR data (12, 6, 3.6 kbit/s)
HR speech version 3
Circuit pool n. 25 FR speech version 1
FR speech version 2
FR speech version 3
FR data (12, 6, 3.6 kbit/s)
HR speech version 3
Circuit pool n. 26 FR speech version 1
FR speech version 2
FR speech version 3
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 3
Circuit pool n. 27 FR speech version 1
FR speech version 2
FR speech version 3
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
Circuit pool n. 28 FR speech version 1
FR speech version 2
FR speech version 3
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
Pool Number
(POOL_<n>)
Supported Channels and
Speech Coding Algorithms
Table 14 Circuit Pool Coding


2196 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
Circuit pool n. 29 FR speech version 1
FR speech version 2
FR speech version 3
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
HSCSD max 2 * FR data (12, 6 kbit/s)
Circuit pool n. 30 FR speech version 1
FR speech version 2
FR speech version 3
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
HSCSD max 2 * FR data (14.5, 12, 6 kbit/s)
EDGE FR data (29 kbit/s)
Circuit pool n. 31 FR speech version 1
FR speech version 2
FR speech version 3
FR data (12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
HSCSD max 4 * FR data (12, 6 kbit/s)
Circuit pool n. 32 FR speech version 1
FR speech version 2
FR speech version 3
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
HSCSD max 4 * FR data (14.5, 12, 6 kbit/s)
EDGE max 2 * FR data (29 kbit/s)
EDGE FR data (43.5 kbit/s)
Circuit pool n. 33 FR data (14.5, 12, 6, 3.6 kbit/s)
HR data (6, 3.6 kbit/s)
HSCSD max 4 * FR data (14.5, 12, 6 kbit/s)
EDGE max 2 * FR data (29 kbit/s)
EDGE FR data (43.5 kbit/s)
EDGE max 2 * FR data (32 kbit/s)
Pool Number
(POOL_<n>)
Supported Channels and
Speech Coding Algorithms
Table 14 Circuit Pool Coding


A30808-X3247-M230-6-7619

2197
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
g When the EPOOL parameter of the BSC object is set to TRUE, if all the TSLAs of a
TRAU are set to the NOT-DEFINED value, all TRAC boards of this TRAU go to cold
standby state, and the TRAU loses its functionality.
Circuit pool n. 34 FR speech version 1
FR speech version 2
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR data (6, 3.6 kbit/s)
HSCSD max 4 * FR data (14.5, 12, 6 kbit/s)
EDGE max 2 * FR data (29 kbit/s)
EDGE FR data (43.5 kbit/s)
EDGE max 2 * FR data (32 kbit/s)
Circuit pool n. 35 FR speech version 1
FR speech version 2
FR speech version 3
FR data (14.5, 12, 6, 3.6 kbit/s)
HR speech version 1
HR speech version 3
HR data (6, 3.6 kbit/s)
HSCSD max 4 * FR data (14.5, 12, 6 kbit/s)
EDGE max 2 * FR data (29 kbit/s)
EDGE FR data (43.5 kbit/s)
EDGE max 2 * FR data (32 kbit/s)
Circuit pool n. 42 FR speech version 1 + CTM
Circuit pool n. 43 FR speech version 2 + CTM
Circuit pool n. 44 FR speech version 1 + CTM
FR speech version 2 + CTM
Circuit pool n. 45 FR speech version 1 + CTM
FR speech version 2 + CTM
HR speech version 1 + CTM
Circuit pool n. 46 FR speech version 3 + CTM
HR speech version 3 + CTM
Circuit pool n. 47 FR speech version 1 + CTM
FR speech version 2 + CTM
FR speech version 3 + CTM
HR speech version 3 + CTM
Circuit pool n. 48 FR speech version 1 + CTM
FR speech version 2 + CTM
FR speech version 3 + CTM
HR speech version 1 + CTM
HR speech version 3 + CTM
Pool Number
(POOL_<n>)
Supported Channels and
Speech Coding Algorithms
Table 14 Circuit Pool Coding


2198 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.6 Special Parameter Values - Group 6
Group 6
HOLTHQAMRDL: hoLowerThresQualAMRDL
HOLTHQAMRUL: hoLowerThresQualAMRUL
HOTHAMRCDL: hoThresAMRComprDL
HOTHAMRCUL: hoThresAMRComprUL
HOTHAMRDDL: hoThresAMRDecomprDL
HOTHAMRDUL: hoThresAMRDecomprUL
LOWTQUAMRDL: pcLowerThresQualAMRDL
LOWTQUAMRUL: pcLowerThresQualAMRUL
UPTQUAMRDL: pcUpperThresQualAMRDL
UPTQUAMRUL: pcUpperThresQualAMRUL
The following table shows the conversion of RXQUAL to C/I for database settings
related to the above listed parameters:
RXQUAL medium RXQUAL calculated C/I
6.88 .... 7 7.00 1
6.63 .... 6.87 6.75 2
6.38 .... 6.62 6.50 4
6.13 .... 6.37 6.25 5
5.88 .... 6.12 6.00 6
5.63 .... 5.87 5.75 7
5.38 .... 5.62 5.50 8
5.13 .... 5.37 5.25 8
4.88 .... 5.12 5.00 9
4.63 .... 4.87 4.75 10
4.38 .... 4.62 4.50 11
4.13 .... 4.37 4.25 11
3.88 .... 4.12 4.00 12
3.63 .... 3.87 3.75 13
3.38 .... 3.62 3.50 13
3.13 .... 3.37 3.25 14
2.88 .... 3.12 3.00 14
2.63 .... 2.87 2.75 15
2.38 .... 2.62 2.50 16
2.13 .... 2.37 2.25 16
Table 15 Conversion of RXQUAL to C/I for settings related to AMR HO and PWRC
parameters.


A30808-X3247-M230-6-7619

2199
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
The C/I delivered by this mapping should be seen as Channel Quality Indicator in the
sense of 3GPP 45.009 (section 3.3.1) rather than an estimation of true C/I.
1.88 .... 2.12 2.00 17
1.63 .... 1.87 1.75 17
1.38 .... 1.62 1.50 18
1.13 .... 1.37 1.25 18
0.88 .... 1.12 1.00 19
0.63 .... 0.87 0.75 19
0.38 .... 0.62 0.50 19
0.13 .... 0.37 0.25 20
0 .... 0.12 0.00 20
RXQUAL medium RXQUAL calculated C/I
Table 15 Conversion of RXQUAL to C/I for settings related to AMR HO and PWRC
parameters.


2200 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.7 Special Parameter Values - Group 7
Group 7
The following Service Groups are identified:
SG-1: Signalling on hopping channel
SG-2: Signalling on non hopping channel
SG-3: CS speech FR - EFR - ASCI VBS - ASCI VGCS on hopping channel
SG-4: CS speech FR - EFR - ASCI VBS - ASCI VGCS on non hopping channel
SG-5: CS speech HR on hopping channel
SG-6: CS speech HR on non hopping channel
SG-7: CS data until 9.6 kbit/s or HSCSD 9.6 kbit/s on hopping channel
SG-8: CS data until 9.6 kbit/s or HSCSD 9.6 kbit/s on non hopping channel
SG-9: CS data until 14.4 kbit/s or HSCSD 14.4 kbit/s on hopping channel
SG-10: CS data until 14.4 kbit/s or HSCSD 14.4 kbit/s on non hopping channel
SG-11: CS speech AMR - FR on hopping channel
SG-12: CS speech AMR - FR on non hopping channel
SG-13: CS speech AMR - HR on hopping channel
SG-14: CS speech AMR - HR on non hopping channel
The following Service Dependent attributes are used to handle Service Groups:
SG1HOPAR: sg1HandoverParms
SG2HOPAR: sg2HandoverParms
SG3HOPAR: sg3HandoverParms
SG4HOPAR: sg4HandoverParms
SG5HOPAR: sg5HandoverParms
SG6HOPAR: sg6HandoverParms
SG7HOPAR: sg7HandoverParms
SG8HOPAR: sg8HandoverParms
SG9HOPAR: sg9HandoverParms
SG10HOPAR: sg10HandoverParms
SG11HOPAR: sg11HandoverParms
SG12HOPAR: sg12HandoverParms
SG13HOPAR: sg13HandoverParms
SG14HOPAR: sg14HandoverParms
SG1PCPAR: sg1PowerControlParms
SG2PCPAR: sg2PowerControlParms
SG3PCPAR: sg3PowerControlParms
SG4PCPAR: sg4PowerControlParms
SG5PCPAR: sg5PowerControlParms


A30808-X3247-M230-6-7619

2201
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
SG6PCPAR: sg6PowerControlParms
SG7PCPAR: sg7PowerControlParms
SG8PCPAR: sg8PowerControlParms
SG9PCPAR: sg9PowerControlParms
SG10PCPAR: sg10PowerControlParms
SG11PCPAR: sg11PowerControlParms
SG12PCPAR: sg12PowerControlParms
SG13PCPAR: sg13PowerControlParms
SG14PCPAR: sg14PowerControlParms
In order to have a great flexibility in Handover and Power Control algorithm definition the
operator can differentiate thresholds and flags for Handover and Power Control on
service basis using a set of specific attributes. These service dependent values override
the service independent attributes shared among services, as shown in the following
tables:
When the HAND:SGXHOPAR (X = 1, 2) is different from NULL, SGXHOPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
When the HAND:SGXHOPAR (X = 3, 4) is different from NULL, SGXHOPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
HAND:SGXHOPAR fields Service Independent Attributes
hoLowerThresholdLevDL HAND:HOLTHLVDL
hoLowerThresholdLevUL HAND:HOLTHLVUL
hoThresholdLevDLintra HAND:HOTDLINT
hoThresholdLevULintra HAND:HOTULINT
hoRxlevDLinner HAND:HORXLVDLI
hoRxlevDLouter HAND:HORXLVDLO
hoLowerThresholdQualDL HAND:HOLTHQUDL
hoLowerThresholdQualUL HAND:HOLTHQUUL
Table 16 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X =1..2)
HAND:SGXHOPAR fields Service Independent Attributes
hoLowerThresholdLevDL HAND:HOLTHLVDL
hoLowerThresholdLevUL HAND:HOLTHLVUL
hoThresholdLevDLintra HAND:HOTDLINT
Table 17 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X =3, 4)


2202 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
When the HAND:SGXHOPAR (X = 5, 6) is different from NULL, SGXHOPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
When the HAND:SGXHOPAR (X = 7, 8, 9, 10) is different from NULL, SGXHOPAR
fields override the unspecific attributes shared among Service Groups, as shown in the
following table:
hoThresholdLevULintra HAND:HOTULINT
hoRxlevDLinner HAND:HORXLVDLI
hoRxlevDLouter HAND:HORXLVDLO
hoLowerThresholdQualDL HAND:HOLTHQUDL
hoLowerThresholdQualUL HAND:HOLTHQUUL
hoThresEFRComprDL HAND:HOTHEFRCDL
hoThresEFRComprUL HAND:HOTHEFRCUL
hoThresFRComprDL HAND:HOTHFRCDL
hoThresFRComprUL HAND:HOTHFRCUL
HAND:SGXHOPAR fields Service Independent Attributes
hoLowerThresholdLevDL HAND:HOLTHLVDL
hoLowerThresholdLevUL HAND:HOLTHLVUL
hoThresholdLevDLintra HAND:HOTDLINT
hoThresholdLevULintra HAND:HOTULINT
hoRxlevDLinner HAND:HORXLVDLI
hoRxlevDLouter HAND:HORXLVDLO
hoLowerThresholdQualDL HAND:HOLTHQUDL
hoLowerThresholdQualUL HAND:HOLTHQUUL
hoThresHRDecomprDL HAND:HOTHHRDDL
hoThresHRDecomprUL HAND:HOTHHRDUL
Table 18 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X =5, 6)
HAND:SGXHOPAR fields Service Independent Attributes
Table 17 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X =3, 4)


A30808-X3247-M230-6-7619

2203
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
When the HAND:SGXHOPAR (X = 11, 12) is different from NULL, SGXHOPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
HAND:SGXHOPAR fields Service Independent Attributes
hoLowerThresholdLevDL HAND:HOLTHLVDL
hoLowerThresholdLevUL HAND:HOLTHLVUL
hoThresholdLevDLintra HAND:HOTDLINT
hoThresholdLevULintra HAND:HOTULINT
hoRxlevDLinner HAND:HORXLVDLI
hoRxlevDLouter HAND:HORXLVDLO
hoLowerThresholdQualDL HAND:HOLTHQUDL
hoLowerThresholdQualUL HAND:HOLTHQUUL
rateHoLowerThresholdQualDL HAND:RHOLTQDL
rateHoLowerThresholdQualUL HAND:RHOLTQUL
Table 19 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X = 7, 8, 9, 10)
HAND:SGXHOPAR fields Service Independent Attributes
hoLowerThresholdLevDL HAND:HOLTHLVDL
hoLowerThresholdLevUL HAND:HOLTHLVUL
hoThresholdLevDLintra HAND:HOTDLINT
hoThresholdLevULintra HAND:HOTULINT
hoRxlevDLinner HAND:HORXLVDLI
hoRxlevDLouter HAND:HORXLVDLO
hoLowerThresQualAMRDL HAND:HOLTHQAMRDL
hoLowerThresQualAMRUL HAND:HOLTHQAMRUL
hoThresAMRComprDL HAND:HOTHAMRCDL
hoThresAMRComprUL HAND:HOTHAMRCUL
Table 20 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X = 11, 12)


2204 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
When the HAND:SGXHOPAR (X = 13, 14) is different from NULL, SGXHOPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
When the PWRC:SGXPCPAR (X = 1..10) is different from NULL, SGXPCPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
HAND:SGXHOPAR fields Service Independent Attributes
hoLowerThresholdLevDL HAND:HOLTHLVDL
hoLowerThresholdLevUL HAND:HOLTHLVUL
hoThresholdLevDLintra HAND:HOTDLINT
hoThresholdLevULintra HAND:HOTULINT
hoRxlevDLinner HAND:HORXLVDLI
hoRxlevDLouter HAND:HORXLVDLO
hoLowerThresQualAMRDL HAND:HOLTHQAMRDL
hoLowerThresQualAMRUL HAND:HOLTHQAMRUL
hoThresAMRDecomprDL HAND:HOTHAMRDDL
hoThresAMRDecomprUL HAND:HOTHAMRDUL
Table 21 Correspondence between service dependent and service independent
attributes (SGXHOPAR, X = 13, 14)
PWRC:SGXPCPAR fields Service Independent Attributes
EnableBSPowerControl PWRC:EBSPWRC
EnableMSPowerControl PWRC:EMSPWRC
EnablePowerControlRLFW PWRC:EPWCRLFW
PcLowerThresholdLevDL PWRC:LOWTLEVD
PcLowerThresholdLevUL PWRC:LOWTLEVU
PcUpperThresholdLevDL PWRC:UPTLEVD
PcUpperThresholdLevUL PWRC:UPTLEVU
PcRLFThreshold PWRC:PCRLFTH
PcLowerThresholdQualDL PWRC:LOWTQUAD
PcLowerThresholdQualUL PWRC:LOWTQUAU
PcUpperThresholdQualDL PWRC:UPTQUAD
PcUpperThresholdQualUL PWRC:UPTQUAU
radioLinkTimeoutBs PWRC:RDLNKTBS
pcRLFThreshold PWRC:PCRLFTH
Table 22 Correspondence between service dependent and service independent
attributes (SGXPCPAR, X = 1..10)


A30808-X3247-M230-6-7619

2205
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
When the PWRC:SGXPCPAR (X = 11..14) is different from NULL, SGXPCPAR fields
override the unspecific attributes shared among Service Groups, as shown in the follow-
ing table:
PWRC:SGXPCPAR fields Service Independent Attributes
EnableBSPowerControl PWRC:EBSPWRC
EnableMSPowerControl PWRC:EMSPWRC
EnablePowerControlRLFW PWRC:EPWCRLFW
PcLowerThresholdLevDL PWRC:LOWTLEVD
PcLowerThresholdLevUL PWRC:LOWTLEVU
PcUpperThresholdLevDL PWRC:UPTLEVD
PcUpperThresholdLevUL PWRC:UPTLEVU
PcRLFThreshold PWRC:PCRLFTH
PcLowerThresQualAMRDL PWRC:LOWTQUAMRDL
PcLowerThresQualAMRUL PWRC:LOWTQUAMRUL
PcUpperThresQualAMRDL PWRC:UPTQUAMRDL
PcUpperThresQualAMRUL PWRC:UPTQUAMRUL
radioLinkTimeoutBs PWRC:RDLNKTBS
pcRLFThreshold PWRC:PCRLFTH
Table 23 Correspondence between service dependent and service independent
attributes (SGXPCPAR, X = 11..14)


2206 A30808-X3247-M230-6-7619
CML:BSC
Id:0900d805800dd074
Appendix B: Special Parameter Values
6.8 Special Parameter Values - Group 8
Group 8
RADIOMG: radioMeasGran
RADIOMR: radioMeasRep
Special care has to be applied if the RADIOMR attribute is set at ON for several TRXs,
because the measurement result messages increase considerably the LAPD load
(increased delay times in the BTSE LAPD queues due to the huge amount of
measurement result messages lead to more CHANNEL REQUIRED messages
because of a too late IMMEDIATE ASSIGNMENT command, etc.).
If only one 64 kbit/s LAPD channel is created in BSC and BTSE, the number of full rate
and half rate TRXs for which radio measurements are allowed is limited.
g The expression half(full) rate TRXs only means how many TRXs would be
covered if the HR(FR) channels were on the same TRXs. The intention is to have
a practical and not too detailed result.
Within one BTSM the maximum number of TRXs for which radio measurements are
allowed with RADIOMG set at 1 (corresponding to 480 ms) can be evaluated from the
following rules and from the table below:
N_TRX = N_FR_TRX + 2 * N_HR_TRX
Max_Meas_TRX = Max_MeasFR_TRX + 2 * Max_MeasHR_TRX
Max_MeasFR_TRX = Max_Meas_TRX - 2 * Max_MeasHR_TRX
Max_MeasHR_TRX = (Max_Meas_TRX - Max_MeasFR_TRX) / 2
Meaning:
N_FR_TRX: Number of full rate TRXs
N_HR_TRX: Number of half rate TRXs
Max_MeasFR_TRX: Maximum number of full rate TRXs for which RADIOMR may
be set at ON value.
Max_MeasHR_TRX: Maximum number of half rate TRXs for which RADIOMR may
be set at ON value.
N_TRX Max_Meas_TRX
1 ... 8 N_TRX
9 ... 11 7
12 ... 15 6
16 ... 18 5
19 ... 21 4
22 ... 24 3


A30808-X3247-M230-6-7619

2207
CML:BSC Appendix B: Special Parameter Values
Id:0900d805800dd074
Example:
12 full rate TRXs and 4 half rate TRXs are installed and configured:
N_FR_TRX = 12
N_HR_TRX = 4
N_TRX = N_FR_TRX + 2 * N_HR_TRX = 12 + 2 * 4 = 20
From the table Max_Meas_TRX = 4
This means that when the radio measurements are activated for 2 full rate TRXs
(Max_MeasFR_TRX = 2), the radio measurements are allowed to be activated for one
additional half rate TRX, as Max_MeasHR_TRX = (Max_MeasFR_TRX) / 2 = 1.
If two LAPD channels (64 kbit/s each) are created, the values for Max_Meas_TRX are
as follows:
25 ... 28 2
29 1
30 ... 32 0
N_TRX Max_Meas_TRX
1 ... 16 N_TRX
17 ... 22 16
23 ... 35 15
36 ... 48 14