Sie sind auf Seite 1von 1

iag0420-037.

dgn

6/5/2012

1. EXISTING MASONRY WALL.

6. SUGGESTED ERECTION SEQUENCE:

X
2-4" MAX

2. 2 L6x3 1/2x5/16 LLV

3
THRU MASONRY AT BOTTOM 2 CORNERS

4. OPENING WIDTH - 8" UP TO 4-4" MAXIMUM.

PRIOR TO CUTTING TO AVOID OVERCUTTING.

5. NEW OPENING IN EXISTING 6" MASONRY WALL.

B. MAKE HORIZONTAL CUT AT TOP OF FUTURE OPENING. EXTEND 6" BEYOND EDGE OF OPENING.

C. MAKE VERTICAL CUTS AT 2 "

1 2

EACH SIDE OF OPENING.

D. INSTALL ANGLE AND BOLTS. THRU BOLTS SHALL BE

3 1

INSTALLED IN GROUTED CELLS. IF GROUTED CELLS ARE NOT ENCOUNTERED

SECTION

BREAK INTO CELL ABOVE AND GROUT SOLID FOR 8" ABOVE AND 4" BELOW BOLT LOCATION.

E. MAKE HORIZONTAL CUT AT BOTTOM OF OPENING AND REMOVE MASONRY.

NEW OPENING IN EXISTING MASONRY WALL


' CH2M HILL NOTE TO DESIGNER:

0420-037
DETAIL REF DATE TDC

505-08 15-Mar-2002 L Faria TDR L Faria LCT L Starek XTR N/A B

DESC SIZE

STRUCTURAL