Objectives

- Know How Counter Works -How To Use Comparison Operation With Counter.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

2/11

November 21, 2013

SIEMENS

Counter
Count Up Count Down Set Counter Preset Value Reset Counter
LAD Diagram

I 0.0
CU I 0.1 CD I 0.2 S C#50 I 0.3 R PV

C0 S_CUD Q Q CV CV_BCD

Q 0.0

MW 0

C0 S_CUD I 0.0 CU CD S PV R A CU A CD A L S A R L T A = CV CV_BCD Q Q I0.0 C0 I0.1 C0 I0.2 C#50 C0 I0.3 C0 C0 MW4 C0 Q0.0 Q 0.0 = MW 0

CV/CV_BCD Output

FBD Diagram

I 0.1 I 0.2 C#50 I 0.3

STL

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

3/11

November 21, 2013

SIEMENS

Comparison Operations
I0.0

CMP ==I

Q 0.0

You can use comparison instructions LAD Diagram to compare numerical values:
MW0

I D R

Compare integers Compare integers Compare floating-point numbers

MW2

IN1 IN2

CMP ==I

The values at inputs IN1 and IN2 are compared FBD Diagram == IN1 is equal to IN2 <> IN1 is not equal to IN2 > IN1 is greater than IN2 < IN1 is less than IN2 >= IN1 is greater than or equal to IN2 <= IN1 is less than or equal to IN2.

MW0 MW2

IN1 IN2 & I0.0 A A( L L ==I ) = I0.0 MW0 MW2

Q0.0 =

STL

Q0.0

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

4/11

November 21, 2013

SIEMENS

Exercise:
1- Write a PLC program to control the counting between zero & 9,

by using one input & one counter.

count up count down

0 9 9 0

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

5/11

November 21, 2013

SIEMENS

Answer of Exercise 1:

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

6/11

November 21, 2013