Sie sind auf Seite 1von 1

Heat_Loss

Rtotal [m^2 K / W]
Walls
Roof
Rooflight
Windows

Doors
Floor

Unclad
Clad
WC
Facade
WC
Other
Main
Plant

Unmodified
2.243
2.671
2.503
0.762
1.034
0.700
0.878
1.014
0.170
1.187

Modified
3.001
2.974
3.932
0.762
1.034
0.700
0.878
1.014
0.170
4.510

U [W / m^2 K]
Unmodified
0.45
0.37
0.40
1.31
0.97
1.43
1.14
0.99
5.88
0.84

Maximum
0.35
0.35
0.25
2.2
2.2
2.2
2.2
3.5
2.2
0.25

Suggested Minimum Modification


1

Status
Fail
Fail
Fail
Pass
Pass
Pass
Pass
Pass
Fail
Fail

4.147

Modified
0.33
0.34
0.25
1.3
1.0
1.4
1.1
1.0
5.9
0.22

0.24

Increase insulation thickness to 75mm


Increase insulation thickness to 60mm
Increase insulation thickness to 100mm
###
###
###
###
###
###
Add 10mm carpet and introduce 1.5m of
horizontal edge insulation with thermal
resistance increase of 1.5
Add 10mm carpet and introduce 1.0m
depth of vertical edge insulation with
thermal resistance increase of 1.0

In order to comply with the limiting values set out in The Building Regulations Approved Document Part L2A (2010), under which the design was begun.