Kultur Dokumente
of Mounting points Load On Each Mounting Required Sattic deflection for 2900 RPM from standard chart Isolation efficiency from chart Linear Proportion Selected Model : P2D Maximum Laod capacity of selected model from polybond catlouge Static deflection of selected model from polybond catlouge The deflection after four mounts will be = = = = 600 CFM 250 MM WC 115 2900 4 28.75 Kg RPM Nos. Kg
= =
0.68 80%
mm
250
Kg
= =
6 0.69
mm mm
115 Kg
ANTIVIBRATION MOUNTS SELECTION Capacity Of fan: Total Wt of Centrifugal Fan Design RPM of the Fan No. of Mounting points Load On Each Mounting Required Sattic deflection for 2900 RPM from standard chart Isolation efficiency from chart Linear Proportion Selected Model : P3D Maximum Laod capacity of selected model from polybond catlouge Static deflection of selected model from polybond catlouge The deflection after four mounts will be = = = = 3500 CFM 250 MM WC 225 2900 6 37.5 Kg RPM Nos. Kg
= =
0.68 80%
mm
340
Kg
= =
6 0.66
mm mm
225 Kg