Sie sind auf Seite 1von 140

G E N E R A L C ATA LO G U E 2 0 0 9

Air conditioning solutions

CARRIER EXPERIENCE BACKED BY A LARGE GROUP


Carrier Corporation is a subsidiary of United Technologies Corporation (NYSE: UTX), which employs more than 200.000 people and is present in 180 countries throughout the world. United Technologies is a global corporation made up of world-leading businesses with rich histories of technological pioneering. UTC businesses built the worlds first working helicopter, invented elevators and air conditioning, developed the first commercially available hydrogen fuel cells and designed complete life support systems for the Space Shuttle. Back by the strength of UTC, Carrier is a rich source of ideas, technologies and innovation to help build a better world.

The worlds largest manufacturer of air conditioning, ventilation, heating and refrigeration systems.

Experts in electronic security and fire protection systems and security system monitoring.

The leading supplier of aerospace systems and components, special fluid pumps, and propeller and engine control systems.

Specialists in commercial and military aircraft engines and space propulsion systems.

The worlds largest manufacturer of elevators, escalators and moving walkways.

World leader in the design and manufacture of helicopters for commercial, industrial and military use.

Innovators in hydrogen-powered fuel cells for space, commercial transport and residential applications.

MAKING THE WORLD A BETTER PLACE TO LIVE, WORK AND PLAY


Our mission is to make the world a better place. This mission dates back more than a hundred years to when Willis Carrier invented the basics of modern air conditioning and developed the first air conditioning system. Since then we have worked to create a comfortable, productive and healthy indoor environment, regardless of the weather. We have also made great progress in ensuring that food and other perishables are transported and preserved for safe consumption. In enhancing our safety and comfort, we never forget our responsibility to preserving the global environment. Carrier was the first air conditioning manufacturer to use non-ozone depleting chlorine-free refrigerants. In recognition of our commitment to developing products for a safer, cleaner and less polluted planet, Carrier received the prestigious Ozone Protection Award from the US Environmental Protection Agency (EPA). Today, Carrier is the worlds largest provider of heating, air conditioning and refrigeration solutions.

Quality-first is the mindset of all Carrier employees. We believe in the relentless pursuit of quality in all we do. We are committed to creating innovative products with the durability and efficiency to exceed our customers expectations.

QUaLITYaND RELIaBILITY

Providing optimal service to our customers is a top priority. In every vertical market we serve, across every continent on the globe, we aim to achieve 100% satisfaction, building a strong, loyal and ever-expanding customer base.

CUSTOMER CARE

We are a company of ideas, committed to applying cutting-edge research and development techniques to create solutions that improve environments and enhance human comfort. Our founder inspires us to always reach for the next innovative, unique, powerful and marketable idea.

INNOVATION
5

PARTNERS FOR GREAT CHALLENGES


Carrier air and climate-quality control systems have been chosen to protect many of the worlds most prestigious buildings. With more than 100 years experience and continuous innovation, the Carrier brand is renowned and respected as a reliable partner for every application. The Great Library of Alexandria (Egypt), Singapore Expo, Galleria degli Uffizi (Florence, Italy), Sistine Chapel (Vatican City, Italy), Beijing Palace Museum (China), Tate Modern Gallery (London, UK), Palacio Baluarte (Pamplona, Spain), Monza Autodrome (Italy), the Acropolis Museum (Athens, Greece) just a few of Carriers prestige installations around the world. Carrier cooled the 2008 Beijing Games Carrier provided solutions for nearly 70% of all heating, ventilation, and airconditioning (HVAC) contracts for the games, thanks to Carriers superior performance, reliability and environmentally responsible products.

TEATRO REAL, MADRID SPAIN

THE WORLD BIGGEST TELESCOPE, CERRO LA SILLA CHILE

BRITISH MUSEUM, LONDON UK

BEIJING PALACE MUSEUM CHINA

OPERA HOUSE, SIDNEY AUSTRALIA

THE WHITE HOUSE, WASHINGTON USA

GREAT LIBRARY OF ALEXANDRIA, CAIRO EGYPT




RESEARCH, EXPERIENCE AND INNOVATION


Carrier is the largest organisation in the world committed to research and development related to air conditioning. Protecting the environment is essential for the quality of life for current and future generations. The challenge is to combine this with continuing economic growth in a way that is sustainable in the long term. For more than a century, Carriers vision has been unchanged: to create the ideal indoor climate whatever the weather. Around the world, a Carrier air conditioner is installed every 8 seconds. Advanced design and technology, reliability, pre and after sales assistance are principles of Carriers strategy. Qualityand reliability Carrier quality and reliability are incorporated and guaranteed in all products and systems. They undergo extensive tests, such as a 10-minute system-operating test, prior to shipment. They are also certified by the major international organisations to guarantee the veracity of the information supplied, safety of the products and high process applications standards. All this to guarantee our customers the highest standards of safety and reliability in each of our products. 

PERFORMANCE EUROVENT GUARANTEE Carrier has played a leading role in the Eurovent certification program from the very beginning. Eurovent tests the products and verifies the conformance between test results and the product.

SAFETY FOR THE CUSTOMER In addition to the CE marking, the absolute safety of Carrier products is certified and guaranteed by the prestigious independent performance data published by the manufacturer.

ISO 9001:2000 PROCESS CERTIFICATION All Carrier processes are certified in accordance with the quality management system standard ISO 9001:2000 to assure the customer that products and services conform with the policies.

INDEX

ROOM AIR CONDITIONERS

54DHS/P

51AKP

12 - 13

14 - 15

RESIDENTIAL SYSTEMS

42ADF

42NQV_g

42NQV_m

42NQv_s

42NQ

42HQE_f

16 - 17

18 - 19

20 - 21

22 - 23

24 - 25

26 - 27

LIGHT COMMERCIAL SYSTEMS

42XPP

42XPF

42NYf

40vmc_N

40xpK

40XPk

40NYk

40kMC_N

40xpD

40xpD

40xpm

40xpL

40NYD

28 - 29

30 - 31

32 - 33

34 - 35

36 - 37

38 - 39

40 - 41

42- 43

44 - 45

46 - 47

48 - 49

50 - 51

52 - 53

LIGHT COMMERCIAL SYSTEMS

PACKAGED SYSTEMS

40DMC

40SMC_N

FB4X

38TYg

38GL_M/ YY_M

CONTROLS

40ALZ/ABZ

50TZ/YZ

50VZ/PZ

50JZ

50AZ/UZ

48AZ/UZ

54- 55

56 - 57

58 - 59

60 - 61

62 - 73

74 - 75

76 - 77

78 - 79

80 - 81

82 - 83

84 -85

86 - 87

ELECTRONIC CONTROLLER FOR FAN COIL UNITS

HYDRONIC TERMINALS SYSTEMS


HDBCONTROLS

42N

42CE

42GW

42DW

42WTN

42VP

42GM

42EM

42GR

42BJ

35BD

88 - 89

90 - 91

92 - 93

94 - 95

96 - 97

98 - 99

100 - 101

102 - 103

104 - 105
fiche.indd 3

106- 107

A STEP TOWARDS ENHANCED COMFORT

108 - 109

110 - 111

10/04/08 14:04:15

CHILLERS AND HEAT PUMPS


30RA/RH 005-015 30RA/RH 017-033 30RA/RH 040-240

30RH

30RB182-802

30RQ

30RY/30RYH 30RW/RWA

30XA

30xw/xwh

30HXC

AQUASMART

112- 113

114 - 115

116 - 117

118 - 119

120- 121

122 - 123

124 - 125

126 - 127

128 - 129

130 - 131

132 - 133

134 - 135

CONTROLS
PRo-DIaLog PLUs ComfoRT ZoNE II

MAESTRO

136

137

138 - 139

Indoor unit data (except Satellite models) Sound pressure level measured in a free field according to JIS9612 Standard Performances evaluated with 5m interconnecting tubes and according to EN14511 Indoor unit data (Satellite models) Sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall Performances evaluated with 5m interconnecting tubes and according to EN14511 Outdoor unit data (All models) Sound pressure level measured in emispheric field at 4m Performances evaluated with 5m interconnecting tubes and according to EN14511 Split systems performance data are based on the following conditions: Cooling capacity: indoor air temperature 27C dry bulb / 19C wet bulb, outdoor air temperature 35C dry bulb / 24C wet bulb Heating capacity: indoor air temperature 20C dry bulb / 15C wet bulb, outdoor air temperature 7C dry bulb / 6C wet bulb Portable units Sound pressure level measured in a free field at 2,5m Performance data according to EN14511

HDB

INDEX

54DHS/p

Choose your favourite dehumidifier! FEATURES


All models use non ozone depleting refrigerant. SILENT AND LIGHT 2-SPEED TURBO VENTILATOR Large-capacity tank positioned at the front of the unit for easy removal.

The dehumidifier stops automatically when the tank is full.

UNIQUE SMART COMFORT FUNCTION: IT AUTOMATICALLY SELECTS THE IDEAL HUMIDITY LEVEL (IDEALDAY 23)

2-speed turbo ventilator quickly achieves the set conditions.

Special antibacterial filter prevents growth of bacteria and mould for a purer and healthier environment (Idealday 23 and 18H). Electronic control with multifunctional liquid crystal display with clock and timer functions for precise regulation of the humidity level (Idealday 23 and 18H). A version available with heater (800W) speeds humidity absorption,to givea pleasant sensation of warmth (Idealday 18H). Unique Smart Comfort function: it automatically selects the ideal humidity level (Idealday 23).

12

Dehumidifiers

Model Capacity at 32C and 80% relative humidity Power input at 27C and 60% relative humidity Fan speeds Air flow Tank capacity Anti-odour filter Anti-bacterial filter Electrical resistance Continuous drain pump Tank full light and automatic power off Automatic defrosting system Electronic humidity controller Digital control Castors Carrying handles Operating limits Refrigerant Dimensions (l h d) Weight Smart comfort function mm kg C W m3/h l l/24h W

54DHS011_R 11 205 1 100 6 Yes Yes Yes Yes Yes Yes 5 35 R134A 310 540 320 15 -

54DHS014_R 14 232 2 110 6 Yes Yes Yes Yes Yes Yes Yes 5 35 R134A 310 540 320 15.5 -

54DHP018 18 380 2 160 7 Yes Yes Yes Yes Yes Yes Yes 5 35 R134A 345 722 23325 19.5 -

54DHP018H 18 380 2 160 7 Yes 800 Yes Yes Yes Yes Yes Yes Yes 5 35 R134A 345 722 325 19,5 -

54DHP023 23 410 2 180 7 Yes Yes Yes Yes Yes Yes Yes Yes 5 35 R134A 345 722 325 19,5 Yes

CARRIER HAS A SOLUTION FOR EVERYBODY!

Do you want a technological and elegant dehumidifier? Idealday 54DHP is the right solution: its electronically controlled and thanks to the unique Smart comfort function, the right level of humidity is automatically achieved.

54DHP018H 54DHP023

Do you prefer a light and user-friendly dehumidifier? Idealday 54DHS is the best choice: it is light and easy to use and can be simply moved in every room of your house.

54DHS011_R 54DHS014_R

13

54DHS/p

51AKP - PORTABLE

IGLOO MAKES YOUR HOME COOL! Igloo is the Carrier portable air conditioning unit: comfort and style for any room.
R410A: Ozone-friendly, non-flammable refrigerant. Unique Italian design.

CONTROLS

FEATURES
A complete range of different capacity and colour combinations to suit all user requirements with powerful and efficient solutions.

Three products in one: air conditioner, dehumidifier and fan.

Infrared

Outstanding Italian design: the rounded lines and the sophisticated details enrich the unique unit appeal. Silent function the lights are dimmed, fresh air is supplied at a soft whisper: ideal conditions for relaxed and silent sleep. Special filtration set: Silver filter to eliminate bacteria, and Active Carbon filter against odours (51AKP260H). Large and clear LCD display both on the front panel and on the remote control. The advanced, immediate and intuitive technology allows easy and precise programming of personal comfort conditions.

14

Room air conditioners

Model Cooling capacity Power input E.E.R. E.E.R. for energy class Energy efficiency class Annual energy consumption Dehumidification Air flow (l/h) Sound pressure (l/h) Noise (l/h) Sound power (l/h) Dimensions IU (h w d) Weight Power supply Air discharge tube max length Current drawn (cooling mode) Model Color Fan speeds Thermostat Separate dehumidification Separate ventilation Electronic controls Autofan Sleep function Heating Timer Filters Remote control Refrigerant n KWh l/h l/s dB(A) dB(A) Lw(A) mm kg V-ph-Hz mm A kW W W/W W/W

51AKP240_M 2,5 875 2,86 2,62 A 438 1,1 61/111 43 48 54,1 56,9 n.a. 860 480 410 36 230-1-50 2000 5,2 51AKP240_M White/Blue 3 Yes Yes Yes Yes Yes Yes Yes Active Carbon Yes R410A

51AKP310_M 3,1 1225 2,53 2,22 C 613 1,3 61/111 44 49 54,9 57,4 65 68,6 860 480 410 36 230-1-50 2000 6 51AKP310_M White/Blue 3 Yes Yes Yes Yes Yes Yes Yes Active Carbon Yes R410A

51AKP260H 2,7 940 2,83 2,61 A 470 1,1 61/111 43 48 54,1 56,9 n.a. 860 480 410 36 230-1-50 2000 5,2 51AKP260H Silver 3 Yes Yes Yes Yes Yes Yes Active Carbon+Silver Yes R410A Yes

The stylish portable that cleans your air Not only does this elegant unit cool the indoor air, it also purifies it, with its special Silver and Active Carbon filters.

51AKP260H

A pretty portable for your home. Its light colours and its modern design make this unit a discreet and user-friendly air conditioner, and, thanks to the Active Carbon filter, the air is always deodorised.

51AKP240M 51AKP310M

15

51AKP

42ADF

DIAMOND IS AN AMAZING INNOVATION IN CARRIERS RESIDENTIAL RANGE: IT IS MOUNTED VERTICALLY, EITHER IN A CORNER OR ON THE WALL AND IS BEAUTIFUL TO LOOK AT, EASY TO CONCEAL. I.A.Q
BIO ANTI-FUNGUS PRE FILTER ANTI-DUST ELECTROSTATIC FILTER ANTI-ODOUR FILTER

FEATURES
Designed for flexibility, the unit may be corner mounted, making it ideal for applications where wall space is at a premium. It is also suitable for wall mounting. Optimised air distribution with 2 vertical fans. It avoids direct air flow.

CONTROLS

Unique design: vertical, modern, and unobtrusive. It fits perfectly in every ambient. Infrared

OUTDOOR UNITS

DC Inverter technology, delivering A-energy class in both cooling and heating, for optimized energy saving. Wide choice of easily changeable coloured panels to adapt to any interior decor.

Single split: 38VYX_R

ACCESSORIES
Clean, purified air thanks to bio pre-filter, anti-dust filter and anti-odour filter.

UL Demko, Eurovent, ISO certified factory. Ivory (standard) Aluminium Coral Artic blue

16

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow (max.) Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO/HP CO/HP HP HP CO CO CO

Size kW kW kW W W/W

25 2,5 0,9 3 760 3,29 A

35 3,5 1,1 4 1070 3,27 A 535 4,2 1,1 5,8 1129 3,72 A 42ADF035 1,3 101/116/132 35/38/41 48/52/55 820 390 185 14,6 230-1-50 38VYX035-R DC Rotary 15 10 15 3/8 1/4 2410 48/50 63/65 550 780 270 36 9,3 220/240-1-50 15 43 10 24

kWh kW kW kW W W/W

380 3,2 0,9 4 840 3,81 A

Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model

42ADF025 1,1 92/108/124 33/36/39 47/50/53 820 390 185 14,6 230-1-50 38VYX025-R DC Rotary

m m m

10 8 10 3/8 1/4

m/h dB(A) dB(A) mm kg A V-ph-Hz C C

1320 46/47 60/61 530 660 240 30 8,3 220/240-1-50 15 43 10 24

17

42ADF

42NQV_G - HI-WALL

THE MOST ENERGY EFFICIENT UNIT, WITH THE LARGEST FILTRATION SURFACE: THE IDEAL COMBINATION FOR DEMANDING APPLICATIONS. I.A.Q
SUPER-SIZE FILTERS DEODORISING NANO PHOTOCOPPER ZINC ANTI-BACTERIA NANO SILVER ENERGISING GINSENG

FEATURES
Modern, elegant design: flat panel with aluminium deco and temperature display. The highest energy efficiency for maximum savings and optimal comfort. A-energy class labelling in both cooling and heating for all models.

CONTROLS

Efficient operation with low ambient temperature, in cooling and heating. Nirvana revitalising air purification, with nano technology. The largest filter available, with energising ginseng, deodorising photo-copper and anti bacteria Nano Silver and Nano Zinc. Unique personal comfort with night-light feature. It provides dim light in case of need.

Infrared

OUTDOOR UNITS

Single split: 38NYV_H

The lowest indoor unit sound levels, only 21dB(A)

ACCESSORIES
White panel Supersize Nano Silver Ginseng Supersize Nano Photo Copper Zinc filter pack UL Demko, Eurovent, ISO certified factory.

18

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow (max.) Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO CO CO HP HP CO CO CO

Size kW kW kW W W/W

25 2,5 1,1 3 658 3,8 A

35 3,5 0,8 4 1025 3,41 A 512,5 4,2 0,9 5,7 1135 3,7 A 42NQV035G* 2 150 27/34/40 40/47/53 275 790 205 9 220-240/1/50 38NYV035H2 DC Twin Rotary 20 10 15 3/8 1/4 2250 48 61 550 780 290 35 12,6 220/240-1-50 10 46 15 24

45 4,5 0,8 4,9 1400 3,21 A 700 5,5 0,9 6,8 1525 3,61 A 42NQV045G 2,5

kWh kW kW kW W W/W

329 3,2 0,9 4,7 810 3,95 A

Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model

42NQV025G 1,5 143 27/34/39 40/47/52 275 790 205 9 220-240/1/50 38NYV025H DC Twin Rotary

31/41/46 44/54/59 275 790 205 9 220-240/1/50 38NYV045H DC Twin Rotary 20 10 15 1/2 1/4 2160 49 62 550 780 290 39 12,6 220/240-1-50 10 46 15 24

m m m

20 10 15 3/8 1/4

m3/h dB(A) dB(A) mm kg A V-ph-Hz C C

1800 46 59 550 780 290 35 8,1 220/240-1-50 10 46 15 24

19

42NQV_G

190

42NQV_M - HI-WALL

A-labelled unit delivering high performance with maximum savings. Its a pleasure to use, every day. I.A.Q
DEODORISING NANO PHOTOCOPPER ZINC ANTI-BACTERIA NANO SILVER ENERGISING GINSENG

FEATURES
DC Rotary Inverter, A-energy class in cooling and heating, for maximum energy saving.

CONTROLS

New design with clean, modern lines to suit all interiors.

Extremely quiet indoor and outdoor units. Infrared Revitalising air filtration: clean, energised air with Nano Silver Ginseng technology: deodorising nano Photo-copper zinc, anti-bacteria Nano Silver, energizing Ginseng. New remote control with Sleep function, Economy, High Power mode and Preset function. Single split: 38NYV_M

OUTDOOR UNITS

ACCESSORIES
Nano Silver Ginseng Nano PhotoCopper Zinc

20

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow (max.) Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO CO CO HP HP CO CO CO

Size kW kW kW W W/W

25 2,5 1,1 2,9 770 3,25 A

35 3,5 1,1 3,9 1090 3,21 A 545 4,2 0,9 4,9 1150 3,65 A 42NQV035M 2 156 27/34/40 40/47/53 275 790 205 9 220/240-1-50 38NYV035M DC Rotary 20 10 15 3/8 1/4 2100 48 61 550 780 290 35 8,1 220/240-1-50 10 46 15 24

45 4,5 0,8 4,9 1600 2,81 C 800 5,3 0,9 6,1 1555 3,41 B 42NQV045M 2,5 192 31/41/46 44/54/59 275 790 205 9 220/240-1-50 38NYV045M DC Twin Rotary 20 10 15 1/2 1/4 2100 49 62 550 780 290 35 12,6 220/240-1-50 10 46 15 24

50 5 1,1 6 1510 3,31 A 755 5,8 0,8 6,3 1605 3,61 A 42NQV050M 2,8 265 44 59

60 6 1,2 6,7 1995 3,01 B 997,5 7 1 7,5 2180 3,21 C 42NQV060M 3,5 300 47 62

kWh kW kW kW W W/W

385 3,2 0,9 4 885 3,62 A

Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model

42NQV025M 1,5 145 30/34/39 43/47/52 250 740 195 8 220/240-1-50 38NYV025M DC Rotary

320 1050 228 320 1050 228 13 220/240-1-50 38NYV050M DC Twin Rotary 20 10 15 1/2 1/4 1914 49 64 550 780 290 39 11,5 220/240-1-50 10 46 15 24 13 220/240-1-50 38NYV060M DC Twin Rotary 20 10 15 1/2 1/4 2232 52 67 550 780 290 40 12,9 220/240-1-50 10 46 15 24

m m m

10 8 10 3/8 1/4

m/h dB(A) dB(A) mm kg A V-ph-Hz C C

1620 48 61 530 660 240 29 4,8 220/240-1-50 15 43 10 24

21

42NQV_M

42NQV_S - HI-WALL

A class performance for vital, year round well-being.

I.A.Q
DEODORISING ACTIVE CARBON PURIFYING ELECTROSTATIC

FEATURES
A energy class in cooling and heating: top class energy saving.

CONTROLS

Extremely low indoor noise: only 21dB(A)*.

Infrared

XPower DC Inverter rotary compressor: guaranteed quality and reliability.

OUTDOOR UNITS

Pure, clean air via anti-odour and anti-dust filters.

New stylish design for demanding European users. Single split: 38NYV_E

ACCESSORIES
Filter pack

Intuitive, easy-to-use remote control.

* Model 42NQV012S at low speed from 2,5m distance.

22

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow (max.) Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO CO CO HP HP CO CO CO

Size kW kW kW W W/W

09 2,5 1,1 2,9 780 3,21 A

12 3,4 1,1 3,9 1060 3,21 A 530 4,15 1 4,9 1150 3,61 A 42NQV012S/S2 2

kWh kW kW kW W W/W

390 3,15 0,9 4 870 3,62 A

Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model

42NQV009S/S2 1,5 145 30/34/39 43/47/52 250 740 195 8 220-240/1/50 38NYV009S/S2 DC Rotary

27/34/40 40/47/53 275 790 205 9 220-240/1/50 38NYV012S/S2 DC Rotary 20 10 15 3/8 1/4 2100 48 61 550 780 290 35 8,1 220-240/1/50 10 46 15 24

m m m

10 8 10 3/8 1/4

m/h dB(A) dB(A) mm kg A V-ph-Hz C C

1620 48 61 530 660 240 29 4,77 220-240/1/50 15 43 10 24

23

42NQV_S

156

42NQ - HI-WALL

I.A.Q
ANTI-ODOUR ANTI-DUST

The new A class Crystal system from Carrier is easy to use and provides immediate comfort and pure environment, in all seasons, with low energy consumption.

FEATURES
A energy class in cooling and heating: reduced energy bill.

CONTROLS

Extremely low indoor noise for absolute comfort. Infrared

OUTDOOR UNITS

Clean and polished apperance: innovative conceptual design has allowed to reduce unit size to the most compact solution for bedrooms.

Pure and deodorised air with anti-odour and anti-dust filters.

Single split: 38NY

Intuitive to use remote control: no need to read user manual.

ACCESSORIES
Replacement filters.

24

Fixed speed split systems

Heat Pump systems Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (max.) Nominal air flow (max.) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor Type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO CO CO HP HP CO CO CO

Size kW W W/W

09 2,73 850 3,21 A

12 3,70 1150 3,22 A 575 4,15 1150 3,61 A 42NQ012 2,0 172 180 32/36/42 45/49/55 275 790 205 9 220-240/1/50 38NY012 Rotary AC 15 6 15 1/2 1/4 2160 51 64 550 780 290 38 7,2 220/240-1-50 15 43 10 24

18 5,11 1590 3,21 A 795 5,49 1520 3,61 A 42NQ018 2,0 277 277 35/39/44 48/52/57 320 1050 228 13 220/240-1-50 38NY018 Rotary AC 20 8 15 1/2 1/4 2475 57 70 715 780 290 47 10,23 220/240-1-50 15 43 10 24

24 6,33 2250 2,81 C 1125 6,85 2130 3,22 C 42NQ024 2,5 305 305 37/41/45 50/54/58 320 1050 228 13

kWh kW W W/W

425 2,93 810 3,62 A

Model l/h l/s l/s dB(A) dB(A) mm kg V-ph-Hz Model

42NQ009 1,2 141 155 32/36/40 45/49/53 250 740 195 8 220-240/1/50 38NY009 Rotary AC

38NY024 Rotary AC 25 10 15 1/2 1/4 2475 57 70 715 780 290 53 15,0 220/240-1-50 15 43 10 24

m m m

10 5 10 3/8 1/4

m3/h dB(A) dB(A) mm kg A V-ph-Hz C C

1795 48 61 550 780 290 31 5,9 220/240-1-50 15 43 10 24

25

42NQ

220/240-1-50

42HQE_F/QC - HI-WALL

ALLEGRO PLUS IS THE FRIENDLY AIR-CONDITIONER THAT COOLS IN SUMMER AND WARMS IN WINTER REAL COMFORT YEAR ROUND. I.A.Q
PASSIVE ELECTROSTATIC ANTI-BACTERIA

FEATURES
Four units in one: dehumidifier, heater, air conditioner and fan. A product for all seasons.

CONTROLS
Flat panel for a modern and fashionable look.

Allegro Plus operates with R410A, the non ozone depleting refrigerant for better performance. Infrared Easy to use remote control to programme comfort, quickly. The wide display gives a clear accurate view of the live setting.

OUTDOOR UNITS

Customised air flow thanks to the adjustable louvers.

Single split: 38YE

The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating.

QUICK COUPLING
Available also with quick coupling: 42HQE_QC (Connections 4m)

26

Fixed speed split systems

Heat Pump systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heating capacity Power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas - liquid) Air flow Sound pressure Sound power Dimensions (h l d) Weight Maximum running current Power supply Operating range (min/max) Operating range (min/max) CO HP HP

Size kW W W/W

09 2,5 889 2,81 C

12 3,5 1245 2,81 C 623 4 1246 3,21 C 42HQE012F/QC 1,2 105/130/165 32/35/42 45/48/55 280 815 195 10,5 230-1-50 38YE012G/QC Rotary 10 5 5 1/2" 1/4" n.a. 41 61 550 780 270 40 n.a. 230-1-50 11 43 10 24

kWh kW W W/W

445 2,9 903 3,21 C

Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model

42HQE009F/QC 1 95/110/125 34/36/39 47/49/52 250 750 188 8,5 230-1-50 38YE009G/QC Rotary

m m m

10 5 5 3/8" 1/4"

m/h dB(A) dB(A) mm kg A V-ph-Hz C C

n.a. 40 60 550 780 270 32 n.a. 230-1-50 11 43 10 24

27

42HQE_F / QC

plus

42XPP - HI-WALL

CONTROLS

XPower Plus Sensation light commercial high-wall offers optimised comfort with excellent seasonal efficiency. Air4Life filtration with the addition of the ionizer can provide superior indoor air Quality.
Room controller

Zone manager

FEATURES
Guaranteed cooling operation from 15C to +46C outdoor temperature. Heating performance even at 15C outdoor temperature. Suitable for applications that require up to 70m distance between the indoor and the outdoor unit. Customised air distribution: six different air flow positions and exclusive Twin Swing air distribution function.

Infrared

OUTDOOR UNITS

Stable indoor comfort and extremely low room temperature fluctuation.

Single split: 38XPS

Continuous low-speed operation ensures exceptional low noise levels for superior acoustic comfort. Powerful dehumidification ensures humidity level control during all seasons.

ACCESSORIES
Filter kit: photocatalytic and passive electrostatic filters.

28

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO HP HP CO CO HP HP HP HP CO CO CO

Size kW kW kW W W/W

50 5,00 0,76 5,78 1560 3,21 A

65 6,00 0,79 6,47 1995 3,01 B 998 6,70 0,82 8,5 2385 2,81 D 42XPP070 3 210/235/260 38/42/46 51/55/59 37/40/43 50/53/56 295 1080 200 14 230-1-50 38XPS065H7 Twin rotary 30 30 20 5/8 3/8 2820 46 66 49 69 820 900 320 51 230-1-50 15 46 15 24

70 6,50 1,68 7,73 2160 3,01 B 1080 6,80 1,83 8,54 2420 2,81 D 42XPP070 3,1 210/235/260 38/42/46

kWh kW kW kW W W/W

780 5,00 0,85 6,37 1465 3,41 B

Model l/h l/s dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz Model

42XPP050 2,70 210/235/260 38/42/46 51/55/59 37/40/43 50/53/56 295 1080 200 14 230-1-50 38XPS050H7 Twin rotary

37/40/43 50/53/56 295 1080 200 14 230-1-50 38XPS070H7 Twin rotary 50 30 20 5/8 3/8 2670 45 65 48 68 820 900 320 73 230-1-50 15 46 15 24

m m m

50 30 20 1/2 1/4

m3/h dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz C C

2620 44 64 45 65 690 900 320 49 230-1-50 15 46 15 24

29

42XPP

51/55/59

plus

42XPF - CONSOLE

CONTROLS

Zone manager

Room controller

The new XPower Plus 42XPF console units provide optimised comfort levels with an excellent seasonal energy efficiency ratio. They are slim and stylish and designed for wall or under the ceiling mounting. Carrier Air4Life filters set provide superior indoor air Quality.

FEATURES
Its compact dimensions make possible a wide range of applications, even under a window sill. All units can be mounted on walls on under the ceiling. Infrared The smaller sizes have been designed for fitting luxury houses and prestigeus offices. They have been recognised with the design award by the Italian Association of Industrial Design (ADI). Equipped with titanium photo-catalytic filters that remove odours and impurities up to 0,01mm. The filter can be washed and regenerated in sunlight. MyComfort remote control function enables the user to preset the preferred settings. Motorised louvre allows air flow to be directed to meet individual preferences. State-of-the art fans and the advanced slimline coil make this a very quiet unit. Guaranteed cooling operation from 15C to +46C outdoor temperature. Heating performance even at 15C outdoor temperature. Suitable for applications that require up to 70m distance between the indoor and the outdoor unit.

OUTDOOR UNITS

Single split: 38XPS

ACCESSORIES
Condensate discharge pump. Piping cover kit.

30

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO HP HP CO CO CO HP HP CO CO CO CO CO CO CO HP HP HP HP HP HP

Size kW kW kW W W/W

50 4,95 0,77 5,77 1645 3,01 B

65 6,00 0,85 7,01 1995 3,01 B 998 6,30 0,85 8,87 1965 3,21 C 42XPF065 2,7 165/195/220 41/44/49 52/55/60 41/44/50 52/55/60

70 7,00 1,81 8,32 2180 3,21 A 1090 7,20 1,83 8,54 2110 3,41 B 42XPF070 1,83 305/325/345 45/47/49 58/60/62 45/47/49 58/60/62

100 10,00 3,41 12,50 3115 3,21 A 1558 11,20 3,65 14,12 3280 3,41 B 42XPF100 3,65 405/440/470 43/45/47 56/58/60 43/45/47 56/58/60

125 12,10 3,40 14,77 4025 3,01 n.a. 13,10 3,70 16 3840 3,41 n.a. 42XPF125 5,5 390/420/450 43/45/47

kWh kW kW kW W W/W

823 5,30 0,85 6,44 1555 3,41 B

Model l/h l/s dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz Model

42XPF050 1,70 150/170/205 38/41/45 49/52/56 38/41/46 49/52/56

43/45/47 56/58/60

598 1000 200 598 1000 200 628 1200 233 628 1650 233 628 1650 233 20 230-1-50 38XPS050H7 Twin rotary 20 230-1-50 38XPS065H7 Twin rotary 30 30 20 5/8 3/8 2820 45 65 48 68 820 900 320 51 230-1-50 15 46 15 24 32 230-1-50 38XPS070H7 Twin rotary 50 30 20 5/8 3/8 2670 45 65 48 68 820 900 320 73 230-1-50 15 46 15 24 46 230-1-50 38XPS100H7 Twin rotary 70 30 30 5/8 3/8 5970 48 68 49 69 49,5 230-1-50 38XPS125H7 Twin rotary 70 30 30 5/8 3/8 6360 50 70 50 70

m m m

50 30 20 1/2 1/4

m3/h dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz C C

2620 44 64 44 64 690 900 320 49 230-1-50 15 46 15 24

1360 900 320 1360 900 320 88 230-1-50 15 46 15 24 88 230-1-50 15 46 15 24

31

42XPF

56/58/60

42NYF - CONSOLE - UNDERcEILINg

I.A.Q
PASSIVE ELECTROSTATIC PHOTOCATALYTIC

The new Carrier console range has been designed not only to be slim and stylish, but also to give high performance.

CONTROLS FEATURES
Zone manager Room controller The large-capacity consoles (sizes 85, 100 and 130) can be wall-mounted or installed under ceiling depending on the requirement. State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet. Motorized louvers allow air distribution direction according to individual preferences Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0,01mm. Filter can be washed and regenerated in sunlight. Easy access to all internal components by removing the grille without removing the front panel Single split: 38BCS/YP, 38GL/YY

Infrared

OUTDOOR UNITS

Possibility of fresh air intake for sizes 85, 100 and 130.

ACCESSORIES
Condensate discharge pump. Hot water coil kit Piping cover kit. Electric heater Cooling operation from 15C to 46C outdoor temperature; heating mode down to 15C.

32

Fixed speed split systems

Cooling Only systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heat Pump systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heating capacity Power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit CO/HP CO/HP CO/HP CO CO CO/HP CO/HP CO/HP CO HP Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Dimensions (h w d) Weight Air flow Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO/HP CO/HP CO/HP CO/HP CO/HP CO CO CO CO CO HP HP HP HP HP CO/HP CO/HP CO HP

Size kW W W/W

85 8,30 2760 3,01 B

85 8,10 2700 3,01 B 1350 85 7,90 2820 2,81 C 1410 8,70 2710 3,21 C 40NYF085 3,1 300/325/345 45/47/49 58/60/62

90 8,50 3030 2,81 C 1515 90 8,30 2960 2,81 C 1480 9,20 2870 3,21 C 40NYF090 3,1 300/325/345 45/47/49 58/60/62

100 10,80 3850 2,81 C 1925 100 10,60 3780 2,81 C 1890 11,20 3490 3,21 C 40NYF100 4 400/440/470 43/45/47 56/58/60

100 10,60 3780 2,81 C 1890 100 10,00 3560 2,81 C 1780 10,30 3210 3,21 C 40NYF100 4 400/440/470 43/45/47 56/58/60

130 11,80 4200 2,81 C 2100 130 11,70 4170 2,81 C 2085 14,40 4490 3,21 C 40NYF130 5,2 390/420/450 43/45/47 56/58/60

kWh Size kW W W/W 80 7,30 2600 2,81 C kWh kW W W/W 1300 7,80 2290 3,41 B Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model Model 40NYF085 2 300/325/345 45/47/49 58/60/62

1380 85 7,80 2780 2,81 C 1390 9,00 2810 3,21 C 40NYF085 3 300/325/345 45/47/49 58/60/62

628 1200 233 628 1200 233 628 1200 233 628 1200 233 628 1650 233 628 1650 233 628 1650 233 32 230-1-50 38NY-080H7 Rotary 32 230-1-50 38NG-085C7 38NY-085H7 Rotary 50 30 15 5/8 3/8 3000 48 68 32 230-1-50 38NG-085C9 38NY-085H9 Rotary 50 30 15 5/8 3/8 3000 48 68 32 230-1-50 38NG-090C7 38NY-090H7 Rotary 50 30 15 5/8 3/8 3000 48 68 46 230-1-50 38NG-100C7 38NY-100H7 Rotary 50 30 15 5/8 3/8 5870 50 70 46 230-1-50 38NG-100C9 38NY-100H9 Rotary 50 30 15 5/8 3/8 5970 50 70 49,5 230-1-50 38NG-130C9 38NY-130H9 Scroll 50 30 15 5/8 3/8 5970 50 70

m m m

50 30 15 5/8 3/8

m3/h dB(A) dB(A) mm kg m3/h dB(A) dB(A) mm kg A V-ph-Hz C C

3041 49 69

820 900 320 820 900 320 820 900 320 1360 900 320 1360 900 320 1360 900 320 64 3000 49 69 64 3000 49 69 68 3000 49 69 87 5870 50 70 87 5970 50 70 95 6070 50 70

820 900 320 820 900 320 820 900 320 820 900 320 1360 900 320 1360 900 320 1360 900 320 58 65 65 69 88 88 96

230-1-50 15 46 15 24

230-1-50 15 46 15 24

400-3-50 15 46 15 24

230-1-50 15 46 15 24

230-1-50 15 46 15 24

400-3-50 15 46 15 24

400-3-50 15 46 15 24

33

42NYf

42VMC_N - CONSOLE

I.A.Q
PASSIVE ELECTROSTATIC PHOTOCATALYTIC

CARRIER CONSOLE UNITS ARE SLIM AND ST YLISH. A VERSATILE SOLUTION, DESIGNED FOR WALL OR UNDER-CEILING INSTALLATION.

CONTROLS FEATURES
Zone manager Room controller Stylish design for modern interiors.

Recognised with an award by the Italian Association of Industrial Design (ADI). Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0,01mm. Filter can be washed and regenerated in sunlight. Infrared

OUTDOOR UNITS

MyComfort remote control function memorises the preferred user settings.

State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet. All key components are easily accessible through the grille without removing the front panel.

Single split: 38BCS/YP, 38GL/YY Multi split: 38GLM/YLM

ACCESSORIES
Condensate discharge pump. Hot water coil kit. Piping cover kit. Electric heater.

34

Fixed speed split systems

Indoor unit Indoor unit with electric heater Outdoor unit (CO) Outdoor unit (CO), Low Ambient version Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption CO CO CO CO CO kWh kW W W/W

42VMC009N 42VMC109N n.a. 38BCS009N 2,69 920 2,92 C 460 38YP-009

42VMC012N 42VMC112N n.a. 38BCS012N 3,27 1200 2,73 D 600 38YP-012 n.a. 2,9 1082 2,68 D 541 3,55 1263 2,81 D 42VMC012N 42VMC112N 1,0 1,5 85/96/114 36/38/42 47/49/53 540 850 200 16 230-1-50 38BCS012N Rotary 15 5 10 38 58 590 750 280 33 1/2 1/4 230-1-50 38YP-012 Rotary 15 5 10 41/43 61/63 520 780 270 40 1/2 1/4 230-1-50

42VMC018N 42VMC318N 38GL018G 38GLP018G 5,34 2190 2,44 E 1095 38YY-018G 38YYS018G 5,26 2090 2,52 E 1045 5,67 2030 2,79 E 42VMC018N 42VMC318N 2,5 2 136/162/199 38/41/46 49/52/57 598 1000 200 18 230-1-50 38GL018G Rotary 30 15 8 45 65 590 800 300 45 1/2 1/4 230-1-50 38YY-018G Rotary 30 15 8 46 66 590 800 300 47 1/2 1/4 230-1-50

42VMC024N 42VMC324N 38GL024G 38GLP024G 6,01 2510 2,39 F 1255 38YY-024N 38YYS024N 6,4 2440 2,62 D 1220 6,8 2470 2,75 E 42VMC024N 42VMC324N 2,5 2,2 164/202/249 41/44/50 52/55/61 598 1000 200 20 230-1-50 38GL024G Rotary 40 15 8 45 65 590 800 300 51 1/2 1/4 230-1-50 38YY-024N Rotary 40 15 8 49 69 803 800 300 60 1/2 1/4 230-1-50

Outdoor unit (HP) Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Indoor unit with electric heater Electric heater Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit (CO) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply V-ph-Hz HP HP m m m dB(A) dB(A) mm kg V-ph-Hz CO CO m m m dB(A) dB(A) mm kg kW l/h l/s dB(A) dB(A) mm kg V-ph-Hz CO CO CO CO CO HP HP HP HP kWh kW W W/W kW W W/W

n.a. 2,49 862 2,89 C 431 2,7 954 2,83 D 42VMC009N 42VMC109N 1,0 1,2 78/88/100 33/36/39 44/47/50 540 850 200 15 230-1-50 38BCS009N Rotary 15 5 10 38 58 590 750 280 30 3/8 1/4 230-1-50 38YP-009 Rotary 10 5 10 40/42 60/62 520 780 270 32 3/8 1/4 230-1-50

35

42VMC_N

plus

40XPK - CASSETTE

CONTROLS

Zone manager

Room controller

The new XPower Plus 40XPK cassette systems provide optimised comfort combined with A-class energy performance in cooling and heating. The clean, stylish shape was recognised with an award from the Italian Association of Industrial Design. The features and the performance make the system the ideal choice for any commercial application, covering the advanced reQuirements of long pipe runs and low-temperature operating limits. FEATURES
A-class energy performance in cooling and heating. Thanks to XPower Plus technology, the systems seasonal efficiency is extremely high.

Infrared

OUTDOOR UNITS

Guaranteed cooling operation from 15C to +46C outdoor temperature. Heating performance even at 15C outdoor temperature. Suitable for applications that require up to 70m distance between the indoor and the outdoor unit. Ease of installation and service for all indoor and outdoor units. All the key components are accessible simply by opening the grille or removing the frontal panel.

Single split: 38XPS

The fresh air intake and additional outlet grille allow an adjoining room to be air conditioned. Fresh air inlet for constant air renewal. Two, three and four way motorised louvres allow air flow direction to be determined by individual preferences. Equipped with photocatalytic titanium filters that remove odours and impurities up to 0,01mm, and high efficiency electrostatic filters.

ACCESSORIES
Air supply outlet obstruction kit.

36

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Grille dimensions (h w d) Grille weight Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Air flow Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO HP HP CO CO CO HP HP CO CO CO CO CO CO CO HP HP HP HP HP HP

Size kW kW kW W W/W

50 5,00 0,77 5,77 1558 3,21 A

65 6,50 0,85 7,01 2024 3,21 A 1012 7,50 0,85 8,87 2075 3,61 A 40XPK070 1,8 200/250/300 32/36/39 45/49/52 32/36/39 45/49/52 298 825 825 30 960 960 6,5 38 230-1-50 38XPS065H7 Twin rotary 30 30 20 2820 45 65 48 68 820 900 320 51 230-1-50 15 46 15 24

70 7,00 1,81 8,32 2181 3,21 A 1091 7,50 1,83 8,54 2078 3,61 A 40XPK070 1,9 200/250/300 32/36/39 45/49/52 32/36/39 45/49/52 298 825 825 30 960 960 6,5 38 230-1-50 38XPS070H7 Twin rotary 50 30 20 2670 45 65 48 68 820 900 320 73 230-1-50 15 46 15 24

100 10,00 3,41 12,50 3115 3,21 A 1558 11,20 3,65 14,12 3102 3,61 A 40XPK100 3,9 320/385/455 37/42/45 50/55/58 37/42/45 50/55/58 298 825 825 30 960 960 6,5 40 230-1-50 38XPS100H7 Twin rotary 70 30 30 5970 48 68 49 69

125 12,50 3,40 14,77 4020 3,01 n.a. 13,10 3,70 16 3743 3,50 n.a. 40XPK125 4,7 400/470/515 43/46/49 56/59/62 43/46/50 56/59/62 298 825 825 30 960 960 6,5 41 230-1-50 38XPS125H7 Twin rotary 70 30 30 6360 50 70 50 70

kWh kW kW kW W W/W

779 5,20 0,85 6,44 1440 3,61 A

Model l/h l/s dB(A) dB(A) dB(A) dB(A) mm mm mm kg V-ph-Hz Model

40XPK050 1,7 190/210/250 38/42/45 51/55/58 38/42/45 51/55/58 298 575 575 30 720 720 3,10 19 230-1-50 38XPS050H7 Twin rotary

m m m m/h dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz C C

50 30 20 2620 44 64 44 64 690 900 320 49 230-1-50 15 46 15 24

1360 900 320 1360 900 320 88 230-1-50 15 46 15 24 88 230-1-50 15 46 15 24

37

40XPK

plus

40XPK - CASSETTE

I.A.Q
PASSIVE ELECTROSTATIC PHOTOCATALYTIC

The XPower Cassettes provide optimised comfort with an excellent seasonal energy efficiency.

CONTROLS FEATURES
All the critical components are accessible simply by opening the grille. Infrared

OUTDOOR UNITS

The fresh air intake and additional outlet grille allow an adjoining room to be air conditioned.

Fresh air inlet for constant air renewal.

Single split: 38NYV_H

Equipped with photo catalytic titanium filters that remove odours and impurities up to 0,01mm, and high efficiency electrostatic filters. Two, three and four way motorised louvres allow air flow direction according to individual preferences.

ACCESSORIES
Air supply outlet obstruction kit.

Stable indoor comfort with minimal temperature fluctuation.

38

Inverter split systems

Heat Pump systems Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Grille dimensions (h w d) Grille weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO CO CO HP HP CO CO CO

Size kW W W/W

25 2,25 745 3,02 B

35 3,5 1090 3,21 A 545 4,2 1077 3,9 A 40XPK040 1,7 190/210/250 38/42/45 51/55/58 298 575 575 19 30 720 720 3,1 230-1-50

45 4,5 1601 2,81 C 801 5,3 1432 3,7 A 40XPK040 1,8 190/210/250 38/42/45 51/55/58 298 575 575 19 30 720 720 3,1 230-1-50 38NYV045H DC Twin Rotary 20 10 15 1/2 1/4 2160 49 62 550 780 290 39 12,6 220/240-1-50 10 46 15 24

kWh kW W W/W

372 3,40 941 3,61 A

Model l/h l/s dB(A) dB(A) mm kg mm kg V-ph-Hz Model

40KQM025 0,9 154/169/184 34/37/39 47/50/52 298 575 575 19 30 720 720 2,5 230-1-50 38NYV025H DC Rotary

38NYV035H
DC Twin Rotary 20 10 15 3/8 1/4 2250 48 61 550 780 290 35 12,6 220/240-1-50 10 46 15 24

m m m

20 10 15 3/8 1/4

m3/h dB(A) dB(A) mm kg A V-ph-Hz C C

1800 46 59 550 780 290 35 8,1 220/240-1-50 10 46 15 24

39

40XPK

40NYK - CASSETTE

I.A.Q
PASSIVE ELECTROSTATIC PHOTOCATALYTIC

For commercial use you need a system with the right conbination of performance and flexibility, making the Carrier cassette the natural choice.

CONTROLS FEATURES
Zone manager Room controller Award from the Italian Association of Industrial Design (ADI)

Two, three and four-way motorized louvers allow air flow direction according to individual preferences Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0,01mm and the high efficiency electrostatic filters. Fresh air intake and additional outlet grille allow air conditioning of an adjoining room. Fresh air inlet for constant air renewal.

Infrared

OUTDOOR UNITS

Cooling operation from 15C to 46C outdoor temperature; heating mode down to 15C. Ease of installation and service for all units; all key components are accessible simply by opening the grille or removing the front panel.

Single split: 38BCS/YP, 38GL/YY

ACCESSORIES
Air4Life kit: photocatalytic titanium and electrostatic filters. Air supply outlet obstruction kit. Electric heater

40

Fixed speed split systems

Cooling Only systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heat Pump systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heating capacity Power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Grille dimensions (h w d) Grille weight Power supply Outdoor unit CO/HP CO HP Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Dimensions (h w d) Weight Air flow Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO/HP CO/HP CO/HP CO/HP CO/HP CO CO CO CO CO HP HP HP HP HP CO/HP CO/HP CO HP CO/HP CO/HP CO/HP CO CO CO/HP CO/HP

Size kW W W/W

85 8,10 2690 3,01 B

85 8,20 2720 3,01 B 1360 85 8,00 2660 3,01 B 1330 8,80 2580 3,41 B 40NYK085IU 3,4 215/265/325 29/32/36 42/45/49 298/825/825 36 30/960/960 5 230-1-50 38NG-085C9 38NY-085H9 Rotary 50 30 15 5/8 3/8 3000 48 68

90 8,60 3060 2,81 C 1530 90 8,50 3020 2,81 C 1510 9,10 2830 3,21 C 40NYK090IU 3,3 285/325/365 33/36/39 46/49/52 298/825/825 38 30/960/960 5 230-1-50 38NG-090C7 38NY-090H7 Rotary 50 30 15 5/8 3/8 3000 48 68

100 11,00 3910 2,81 C 1955 100 10,80 3840 2,81 C 1920 11,10 3460 3,21 C 40NYK100IU 4,1 335/400/460 37/42/45 50/55/58 298/825/825 38 30/960/960 5 230-1-50 38NG-100C7 38NY-100H7 Rotary 50 30 15 5/8 3/8 5870 50 70

100 10,90 3620 3,01 B 1810 100 10,50 3490 3,01 B 1745 10,80 3360 3,21 C 40NYK100IU 4 335/400/460 37/42/45 50/55/58 298/825/825 38 30/960/960 5 230-1-50 38NG-100C9 38NY-100H9 Rotary 50 30 15 5/8 3/8 5970 50 70

130 12,50 4450 2,81 C 2225 130 12,20 4340 2,81 C 2170 14,80 4610 3,21 C 40NYK130IU 4,4 410/450/510 43/46/49 56/59/62 298/825/825 41 30/960/960 5 230-1-50 38NG-130C9 38NY-130H9 Scroll 50 30 15 5/8 3/8 5970 50 70

kWh Size kW W W/W 80 7,20 2560 2,81 C kWh kW W W/W 1280 7,80 2430 3,21 C Model l/h l/s dB(A) dB(A) mm kg mm kg V-ph-Hz Model Model 40NYK085IU 2,5 215/265/325 29/32/36 42/45/49 298/825/825 36 30/960/960 5 230-1-50 38NY-080H7 Rotary m m m 50 30 15 5/8 3/8 m3/h dB(A) dB(A) mm kg m3/h dB(A) dB(A) mm kg A V-ph-Hz C C 230-1-50 15 46 15 24 3041 49 69

1345 85 7,90 2810 2,81 C 1405 9,00 2800 3,21 C 40NYK085IU 3,4 215/265/325 29/32/36 42/45/49 298/825/825 36 30/960/960 5 230-1-50 38NG-085C7 38NY-085H7 Rotary 50 30 15 5/8 3/8 3000 48 68

820 900 320 820 900 320 820 900 320 1360 900 320 1360 900 320 1360 900 320 64 3000 49 69 64 3000 49 69 68 3000 49 69 87 5870 50 70 87 5970 50 70 95 6070 50 70

820 900 320 820 900 320 820 900 320 820 900 320 1360 900 320 1360 900 320 1360 900 320 58 65 65 69 88 88 96

230-1-50 15 46 15 24

400-3-50 15 46 15 24

230-1-50 15 46 15 24

230-1-50 15 46 15 24

400-3-50 15 46 15 24

400-3-50 15 46 15 24

41

40NYk

40KMC - CASSETTE

I.A.Q
PASSIVE ELECTROSTATIC PHOTOCATALYTIC

IF YOU NEED A SYSTEM WITH THE RIGHT COMBINATION OF PERFORMANCE, ST YLE AND FLEXIBILIT Y, THIS CASSET TE IS THE PERFECT CHOICE.

CONTROLS FEATURES
Zone manager Room controller The patented wing-shaped centrifugal fan, new heat exchanger and improved air management system ensure near-perfect acoustic performance. Standard dimensions compatible with all suspended ceiling systems in common use in shops and offices. Recognised with an award by the Italian Association of Industrial Design (ADI).

Infrared

OUTDOOR UNITS

Simply opening the grille gives access to all critical components.

Fresh air intake and additional outlet grille allow air conditioning of an adjoining room. Single split: 38BCS/YP, 38GL/YY Multi split: 38GLM/YLM Two, three and four-way motorised louvres allow air flow direction according to individual preference.

ACCESSORIES
Air4Life kit: photocatalytic titanium and electrostatic filters. Air supply outlet obstruction kit. Electric heater

42

Fixed speed split systems

Indoor unit Indoor unit with electric heater Outdoor unit (CO) Outdoor unit (CO), Low Ambient version Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Outdoor unit (HP) Outdoor unit (HP), Low Ambient version Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Indoor unit with electric heater Electric heater Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Grille dimensions (h w d) Grille weight Power supply Outdoor unit (CO) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply V-ph-Hz HP HP m m m dB(A) dB(A) mm kg V-ph-Hz CO CO m m m dB(A) dB(A) mm kg kW l/h l/s dB(A) dB(A) mm kg mm kg V-ph-Hz CO CO CO CO CO HP HP HP HP kWh kW W W/W kW W W/W CO CO CO CO CO kWh kW W W/W

40KMC012-7N 40KMC112-7EN n.a. 38BCS012N 3,58 1240 2,89 C 620 38YP-012 n.a. 3,23 1088 2,97 C 544 3,73 1196 3,12 D 40KMC012-7N 40KMC112-7EN 1,5 0,8 152/167/183 27/31/34 40/44/47 298/575/575 17,5 30/720/720 2,5 230-1-50 38BCS012N Rotary 15 5 10 38 58 590 750 280 33 1/2 1/4 230-1-50 38YP-012 Rotary 10 5 10 40/42 60/62 520 780 270 32 3/8 1/4 230-1-50

40KMC018-7N 40KMC118-7EN 38GL018G 38GLP018G 5,59 2180 2,56 E 1090 38YY-018G 38YYS018G 4,92 2000 2,46 E 1000 5,38 2160 2,49 F 40KMC018-7N 40KMC118-7EN 1,5 + 1,0 1,9 156/175/194 30/33/36 43/46/49 298/575/575 19 30/720/720 2,5 230-1-50 38GL018G Rotary 30 15 8 45 65 590 800 300 45 1/2 1/4 230-1-50 38YY-018G Rotary 30 15 8 46 66 590 800 300 47 1/2 1/4 230-1-50

40KMC024-7N 40KMC124-7EN 38GL024G 38GLP024G 5,56 2520 2,21 F 1260 38YY-024N 38YYS024N 6,23 2380 2,62 D 1190 7,02 2580 2,72 E 40KMC024-7N 40KMC124-7EN 1,5 + 1,0 2,5 189/213/250 35/38/42 48/51/55 298/575/575 19 30/720/720 2,5 230-1-50 38GL024G Rotary 40 15 8 45 65 590 800 300 51 1/2 1/4 230-1-50 38YY-024N Rotary 40 15 8 49 69 803 800 300 60 1/2 1/4 230-1-50

43

40KMC_N

plus

40XPD - SATELLITE

CONTROLS

Zone manager

Room controller

The new XPower Plus 40XPD ducted systems provide optimised comfort combined with A-class energy performance in cooling and heating. The indoor unit represents a breakthrough in terms of design: its slim profile and flexible installation make this unit the best choice for homes and light commercial applications, even where there are advanced reQuirements such as long pipe runs and low-temperature operating limits. FEATURES
A-class energy performance in cooling and heating. Thanks to XPower Plus technology, the systems seasonal efficiency is extremely high.

Infrared

Guaranteed cooling operation from 15C to +46C outdoor temperature. Heating performance even at 15C outdoor temperature. Suitable for applications that require up to 70 m distance between the indoor and the outdoor unit. Ultra-slim profile only 290mm for all models, thanks to the Carrier-patented V-shaped coil. Designed for front or side air discharge. Thanks to the modular filter and panel sizes, the unit is flexible and can be mounted with rear or base air return. Equipped with pre-punched 150mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. Control box is equipped with 1,5m cable for flexible positioning and accessibility.

OUTDOOR UNITS

Single split: 38XPS

ACCESSORIES
MyComfort infrared kit.

44

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (l/m/h) Sound power (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO HP HP CO CO HP HP CO CO CO CO CO CO CO CO HP HP HP HP HP HP

Size kW kW kW W W/W

50 5,00 0,77 5,77 1557 3,21 A

65 6,60 0,85 7,01 2055 3,21 A 1028 7,00 0,85 8,88 1940 3,61 A 40XPD070 2,5 205/211/269 50 38/40/42 51/53/55 38/40/42 51/53/55 925 750 290 35 230-1-50 38XPS065H7 Twin rotary 30 30 20 5/8 3/8 2820 45 65 48 68 820 900 320 51 230-1-50 15 46 15 24

70 7,00 1,81 8,32 2180 3,21 A 1090 7,20 1,83 8,54 1995 3,61 A 40XPD070 2,6 205/211/269 50 38/40/42 51/53/55 38/40/42 51/53/55 925 750 290 35 230-1-50 38XPS070H7 Twin rotary 50 30 20 5/8 3/8 2670 45 65 48 68 820 900 320 73 230-1-50 15 46 15 24

100S 10,00 3,40 12,50 3115 3,21 A 1558 10,40 3,39 13,11 3050 3,41 B 40XPD100S 4,1 296/356/396 50 39/42/45 52/55/58 39/42/45 52/55/58 925 750 290 49 230-1-50 38XPS100H7 Twin rotary 70 30 30 5/8 3/8 5970 48 68 49 69

100 10,00 3,40 12,50 3120 3,21 A 1560 11,00 3,59 13,87 3050 3,61 A 40XPD100 3,3 390/476/564 80 44/46/49 57/59/62 44/46/49 57/59/62

125 12,50 3,41 14,70 4153 3,01 n.a. 13,10 3,70 16,06 3742 3,50 n.a. 40XPD125 3,8 569/616/667 80 47/51/54 60/64/67 47/51/54 60/64/67

kWh kW kW kW W W/W

779 5,50 0,86 6,44 1523 3,61 A

Model l/h l/s Pa dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz Model

40XPD050 1,6 210/263/290 50 39/40/42 52/53/55 39/40/42 52/53/55 925 750 290 32 230-1-50 38XPS050H7 Twin rotary

1325 750 290 1325 750 290 48 230-1-50 38XPS100H7 Twin rotary 70 30 30 5/8 3/8 5970 48 68 49 69 53 230-1-50 38XPS125H7 Twin rotary 70 30 30 5/8 3/8 6360 50 70 50 70

m m m

50 30 20 1/2 1/4

m3/h dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz C C

2620 44 64 44 64 690 900 320 49 230-1-50 15 46 15 24

1360 900 320 1360 900 320 1360 900 320 73 230-1-50 15 46 15 24 88 230-1-50 15 46 15 24 88 230-1-50 15 46 15 24

45

40XPD

plus

40XPD - SATELLITE

CONTROLS

Optimal comfort: it can be installed in the false ceiling of a corridor or bathroom to limit still further any possible noisein the rooms.

Infrared

OUTDOOR UNITS

FEATURES
Quick and easy to install: the preferred solution for consultants and installers.

Single split: 38NYV_H

Slim profile, the low unit height permits installation even with low ceilings; its compactness and light weight make this unit very competitive. Filters, coils, motors and valves are easily accessible by removing only a few screws. Control box equipped with 1,5m cable for flexible positioning and accessibility. Easy maintenance: filters, fans and coil are easy to reach by removing the screws Easy access to all internal components by removing the grille without removing the front panel

ACCESSORIES
MyComfort infrared kit.

46

Inverter split systems

Heat Pump systems Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO CO CO CO CO CO CO CO HP HP HP HP

Size kW W W/W

40SQM025 2,25 747 3,01 B

40XPD035 3,5 1086 3,22 A 543 4,4 1023 4,3 A 40XPD040 1,6 210/263/290 39/40/42 52/53/55 925 750 290 32 230-1-50 38NYV035H DC Twin Rotary 20 10 15 3/8 1/4 2250 48 61 550 780 290 35 12,6 220/240-1-50 10 46 15 24

40XPD045 4,5 1495 3,01 B 747 5,5 1375 4 A 40XPD040 1,7 210/263/290 39/40/42 52/53/55 925 750 290 32 230-1-50 38NYV045H DC Twin Rotary 20 10 15 1/2 1/4 2160 49 62 550 780 290 39 12,6 220/240-1-50 10 46 15 24

kWh kW W W/W

373 3,4 941 3,61 A

Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model

40SQM025 0,8 103/118/139 42/44/45 56/57/59 220 725 555 23 230-1-50 38NYV025H DC Rotary

m m m

20 10 15 3/8 1/4

m3/h dB(A) dB(A) mm kg A V-ph-Hz C C

1800 46 59 550 780 290 35 8,1 220/240-1-50 10 46 15 24

47

40XPD

plus

40XPM - SATELLITE

CONTROLS

The new XPower Plus 40XPM ducted systems provide optimised comfort combined with A-class energy performance in cooling and heating. The static pressure of the indoor unit (up to 150Pa) makes it suitable for light commercial applications.
Room controller

Zone manager

FEATURES
Guaranteed cooling operation from 15C to +46C outdoor temperature. Heating performance even at 15C outdoor temperature. Suitable for applications that require up to 70m distance between the indoor and the outdoor unit.

Infrared

OUTDOOR UNITS

V-shape coil for better efficiency and performance.

Anti-bacterial filters as standard.

Single split: 38XPS

Flexible installation: left or right piping connections without any adjustment of settings.

ACCESSORIES
MyComfort infrared kit.

Choice of wired or wireless controls.

48

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (l/m/h) Sound power (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow (max) Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO HP HP CO CO HP HP CO CO CO CO CO CO CO HP HP HP HP HP HP

Size kW kW kW W W/W

65 6,60 0,87 7,12 2056 3,21 A

70 7,00 1,81 8,32 2180 3,21 A 1090 7,20 1,83 8,54 1994 3,61 A 40XPM070 1,2 334/416/499 110 55/58/62 68/71/75 55/58/62 68/71/75 385 650 670 35 230-1-50 38XPS070H7 Twin rotary 50 30 20 5/8 3/8 2670 45 65 48 68 820 900 320 73 230-1-50 15 46 15 24

100 10,00 3,41 12,50 3115 3,21 A 1558 11,20 3,65 14,1 3102 3,61 A 40XPM100 1,6 334/416/499 110 55/58/62 68/71/75 55/58/62 68/71/75 385 650 670 35 230-1-50 38XPS100H7 Twin rotary 70 30 30 5/8 3/8 5970 51 71 51 71 1360 900 320 88 230-1-50 15 46 15 24

125 12,50 3,40 14,77 4159 3,01 n.a. 13,10 3,70 16,07 3742 3,50 n.a. 40XPM125 230-1-50 38XPS125H7 Twin rotary 70 30 30 5/8 3/8 6360 50 70 52 72 1360 900 320 88 230-1-50 15 46 15 24

kWh kW kW kW W W/W

1028 7,00 0,85 8,87 1939 3,61 A

Model l/h l/s Pa dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz Model

40XPM070 1,1 334/416/499 110 55/58/62 68/71/75 55/58/62 68/71/75 385 650 670 35 230-1-50 38XPS065H7 Twin rotary

m m m

30 30 20 1/2 1/4

m /h
3

2820 46 66 49 69 820 900 320 51 230-1-50 15 46 15 24

dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz C C

49

40XPM

40XPL - ULTRa Low-sTaTIc SATELLITE

CONTROLS

The ultra slim profile and the flexible installation make this unit the best choice for homes and light commercial applications.
Room controller

Zone manager

FEATURES
Ultra slim profile of the indoor unit is only 241mm. This reduces largely the requirement of the room height. Infrared The discharge opening of the indoor units has flange and screw hole for air supply ducts connection. Quiet operation: the indoor unit is of forward multi-wing impeller design. The low noise, single phase, capacitor type, direct driven motor ensures its super quiet operation. The application of the XPower twin DC rotary inverter driven compressor decrease outdoor units sound level. Single split: 38XP Reliable and durable: the high efficient XPower twin DC rotary inverter driven compressor is durable and free of maintenance. The drain pan of the indoor unit is a unitary shaped up pan and is insulated around the outside surface. It can stand strict condensing test. Extended operating range: from 15 to 46C in cooling mode and from 15 to 24C in heating mode. Suitable for applications that require up to 50m distance between the indoor and outdoor unit.

OUTDOOR UNITS

ACCESSORIES
MyComfort infrared kit.

50

Inverter split systems

Heat Pump systems Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (max.) Sound power (max.) Dimensions (h w d) Weight Power supply Outdoor unit Compressor type Maximum pipe length Maximum height difference Chargeless Air flow (min./max.) Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply CO CO HP HP CO HP HP HP CO CO CO

Size kW kW kW W W/W

40XPL050 5,10 0,78 6,49 1,76 2,90 C

40XPL070 6,50 0,84 6,90 2,24 2,90 C 1120 7,60 0,92 9,64 2,30 3,30 C 40XPL070 1,4 220/305/375 30 42 42 241 1413 469 25,5 230-1-50 38XP-065H7 Twin rotary 30 30 20 2820 47 67 50 70 820 900 320 51 5/8 3/8 230-1-50

40XPL070 7,00 1,81 8,32 2,41 2,90 C 1205 7,85 1,99 9,30 2,38 3,30 C 40XPL070 2,1 220/305/375 30

kWh kW kW kW W W/W

880 5,80 0,91 6,80 1,76 3,30 C

Model l/h l/s Pa dB(A) dB(A) mm kg V-ph-Hz Model

40XPL050 1,3 200/250/305 30 46 46 241 1134 469 20,0 230-1-50 38XP-050H7 Twin rotary

42 241 1413 469 25,5 230-1-50 38XP-070H7 Twin rotary 50 30 20 2670 47 67 50 70 820 900 320 73 5/8 3/8 230-1-50

m m m m3/h dB(A) dB(A) dB(A) dB(A) mm kg in V-ph-Hz

50 30 20 2620 46 66 46 66 690 900 320 49 1/2 1/4 230-1-50

51

40XPL

42

40NYD - SATELLITE

CONTROLS

Zone manager

Room controller

The Carrier Satellite is fixed-speed unit with high performance in term of comfort and energy efficiency. Compact and versatile it is the ideal choice for new or refurbished buildings.

FEATURES
Ultra-slim profile only 290mm for all sizes thanks to the Carrier-patented Vshaped coil Infrared Compact and light: 30% lighter than any other ducted unit on the market; installation on the ceiling is faster and extremely easy

OUTDOOR UNITS

Equipped with pre-punched fresh air intake

Easy maintenance: filters, fans and coil are easy to reach by removing the screws Single split: 38GL/YY Easy access to all internal components by removing the grille without removing the front panel

ACCESSORIES
Hot water coil. Electric heater MyComfort infrared control kit.

Choice of wired or wireless controls.

Cooling operation from 15C to 46C outdoor temperature; heating mode down to 15C.

52

Fixed speed split systems

Cooling Only systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heat Pump systems Cooling capacity Power input E.E.R. Energy efficiency class Annual energy consumption Heating capacity Power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit CO/HP CO/HP CO/HP CO CO CO/HP CO/HP CO/HP CO HP Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (gas liquid) Air flow Sound pressure Sound power Dimensions (h w d) Weight Air flow Sound pressure Sound power Dimensions (h w d) Weight Power supply Operating range (min. max.) Operating range (min. max.) CO/HP CO/HP CO/HP CO/HP CO/HP CO CO CO CO CO HP HP HP HP HP CO/HP CO HP

Size kW W W/W

85 8,30 2950 2,81 C

85 8,30 2760 3,01 B 1380 85 8,30 2760 3,01 B 1380 8,80 2740 3,21 C 40NYD085 3 260/335/375 40/43/46 53/56/59

90 8,80 3130 2,81 C 1565 90 8,80 3130 2,81 C 1565 9,10 2830 3,21 C 40NYD090 3,5 215/300/360 43/46/48 56/59/61

100 11,50 3820 3,01 B 1910 100 11,50 3820 3,01 B 1910 11,90 3490 3,41 B 40NYD100 4,6 400/500/600 46/49/54 59/62/66

100 10,60 3520 3,01 B 1760 100 10,40 3460 3,01 B 1730 10,80 3170 3,41 B 40NYD100 4,6 400/500/600 46/49/54 59/62/66

130 13,30 4730 2,81 C 2365 130 13,30 4730 2,81 C 2365 14,80 4340 3,41 B 40NYD130 3,8 555/600/700 47/51/54 60/64/67

kWh Size kW W W/W 80 7,60 2700 2,81 C kWh kW W W/W 1350 7,70 2400 3,21 C Model l/h l/s dB(A) dB(A) mm kg V-ph-Hz Model Model 40NYD085 2,5 260/335/375 40/43/46 53/56/59

1475 85 8,30 2950 2,81 C 1475 8,50 2650 3,21 C 40NYD085 2,8 260/335/375 40/43/46 53/56/59

295 925 750 295 925 750 295 925 750 295 925 750 295 1325 750 295 1325 750 295 1325 750 42 230-1-50 38NY-080H7 Rotary 42 230-1-50 38NG-085C7 38NY-085H7 Rotary 50 30 15 5/8 3/8 3000 48 68 42 230-1-50 38NG-085C9 38NY-085H9 Rotary 50 30 15 5/8 3/8 3000 48 68 42 230-1-50 38NG-090C7 38NY-090H7 Rotary 50 30 15 5/8 3/8 3000 48 68 52 230-1-50 38NG-100C7 38NY-100H7 Rotary 50 30 15 5/8 3/8 5870 50 70 52 230-1-50 38NG-100C9 38NY-100H9 Rotary 50 30 15 5/8 3/8 5970 50 70 56 230-1-50 38NG-130C9 38NY-130H9 Scroll 50 30 15 5/8 3/8 5970 50 70

m m m

50 30 15 5/8 3/8

m3/h dB(A) dB(A) mm kg m3/h dB(A) dB(A) mm kg V-ph-Hz C C

3041 49 69

820 900 320 820 900 320 820 900 320 1360 900 320 1360 900 320 1360 900 320 64 3000 49 69 64 3000 49 69 68 3000 49 69 87 5870 50 70 87 5970 50 70 95 6070 50 70

820 900 320 820 900 320 820 900 320 820 900 320 1360 900 320 1360 900 320 1360 900 320 58 230-1-50 15 46 15 24 65 230-1-50 15 46 15 24 65 400-3-50 15 46 15 24 69 230-1-50 15 46 15 24 88 230-1-50 15 46 15 24 88 400-3-50 15 46 15 24 96 400-3-50 15 46 15 24

53

40NYD

40DMC - SATELLITE

CONTROLS

THE DUCTED ABOVE-CEILING UNITS REPRESENT A BREAKTHROUGH IN TERMS OF DESIGN. THE SLIM PROFILE AND FLEXIBLE INSTALLATION OPTIONS MAKE THESE UNITS THE BEST CHOICE FOR HOMES AND SMALL COMMERCIAL APPLICATIONS. FEATURES
Ultra-slim profile only 290mm for all sizes, thanks to the Carrier-patented V-shaped coil. Unique design with lateral air discharge allows the unit to be installed in a corridor. Modular filter and panel sizes make the unit flexible and it can be mounted with rear or bottom air return.

Zone manager

Room controller

OUTDOOR UNITS

Single split: 38GL/YY Multi split: 38GLM/YLM

Equipped with pre-punched 150mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. Control box equipped with 1,5m cable for flexible positioning and accessibility. Both electric heater and hot water coil are retrofit outside the unit for easy mounting on installed units.

ACCESSORIES
Hot water coil. Electric heater. MyComfort infrared control kit.

54

Fixed speed split systems

Indoor unit Outdoor unit (CO) Outdoor unit (CO), Low Ambient version Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Outdoor unit (HP) CO CO CO CO CO kWh kW W W/W

40DMC018 38GL018G 38GLP018G 5,40 2151 2,51 E 1075 38YY-018G 38YYS018G

40DMC024 38GL024G 38GLP024G 6,48 2763 2,34 F 1381 38YY-024N 38YYS024N 6,54 2540 2,57 E 1270 7,02 2560

Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor Unit (CO/HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply Outdoor Unit (CO/HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply

CO CO CO CO CO HP HP HP HP

kW W W/W

5,42 2038 2,66 D

kWh kW W W/W

1019 5,64 1828 3,09 D 40DMC018

E 40DMC024 2,0 205/211/269 50 38/40/42 51/53/55 925 750 290 35 230-1-50 38GL024G Rotary 40 15 8 45 65 590 800 300 51 1/2 1/4 230-1-50 38YY-024N Rotary 40 15 8 49 69 803 800 300 60 1/2 1/4 230-1-50

l/h l/s Pa dB(A) dB(A) mm kg V-ph-Hz

1,6 210/263/294 50 39/40/42 52/53/55 925 750 290 32 230-1-50 38GL018G

m m

Rotary 30 15

m CO/HP CO/HP dB(A) dB(A) mm kg in V-ph-Hz

8 45 65 590 800 300 45 1/2 1/4 230-1-50 38YY-018G Rotary

m m m CO/HP CO/HP dB(A) dB(A) mm kg in V-ph-Hz

30 15 8 46 66 590 800 300 47 1/2 1/4 230-1-50

55

40DMC

2,74

40SMC - SATELLITE

CONTROLS

WITH ITS COMPACT SIZE AND FLEXIBILIT Y THIS DUCTED SYSTEM IS THE IDEAL CHOICE FOR BOTH NEW AND REFURBISHED BUILDINGS.
Room controller

Zone manager

OUTDOOR UNITS

FEATURES
Installation flexibility with a wide range of accessories.

The preferred solution for consultants and installers quick and easy to install, compatible with existing electrical and plumbing systems. Single split: 38BCS/YP, 38GL/YY Multi split: 38GLM/YLM Filters, coils, motors and valves are easily accessible by removing only a few screws. Powerful three-speed direct-drive fan delivers air at up to 80Pa external static pressure. Unique slim-line profile the low unit height permits installation even with low ceilings.

ACCESSORIES
Mixing box for fresh air. Octopus two, three or four outlets. High-efficiency gravimetric filter. 3-way, 4-connection valve for hot water coil. MyComfort infrared control kit.

Compact and 30% lighter than other ducted units on the market.

56

Fixed speed split systems

Indoor unit Outdoor unit (CO) Outdoor unit (CO), Low Ambient version Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Outdoor unit (HP) Outdoor unit (HP), Low Ambient version Nominal cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Maximum static pressure Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor Unit (CO) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply Outdoor Unit (HP) Compressor type Maximum pipe length Maximum height difference Pre-charged length Sound pressure Sound power Dimensions (h w d) Weight Flare connections Power supply V-ph-Hz HP HP m m m dB(A) dB(A) mm kg CO CO m m m dB(A) dB(A) mm kg in V-ph-Hz l/h l/s Pa Pa dB(A) dB(A) mm kg V-ph-Hz CO CO CO CO CO HP HP HP HP kWh kW W W/W kW W W/W CO CO CO CO CO kWh kW W W/W

40SMC009N n.a. 38BCS009N 2,71 1030 2,63 D 515 38YP-009 n.a. 2,64 943 2,81 C 472 3,1 891 3,48 B 40SMC009N 0,5 92/103/133 33 60 42/43/44 55/56/57 220 725 555 23 230-1-50 38BCS009N Rotary 15 5 10 38 58 590 750 280 30 3/8 1/4 230-1-50 38YP-009 Rotary 10 5 10 40/42 60/62 520 780 270 32 3/8 1/4 230-1-50

40SMC012N n.a. 38BCS012N 3,41 1250 2,73 D 625 38YP-012 n.a. 3,35 1110 2,83 C 555 3,84

3,24 C 40SMC012N 0,8 103/118/139 40 60 42/44/45 56/57/58 220 725 555 23 230-1-50 38BCS012N Rotary 15 5 10 38 58 590 750 280 33 1/2 1/4 230-1-50 38YP-012 Rotary 15 5 10 41/43 61/63 520 780 270 40 1/2 1/4 230-1-50

57

40SMC_N

1185

FB4X - TECH3000

TECH3000
CONTROLS

ENCASED INDOOR FAN COILS, COMPLETE WITH DIRECT-EXPANSION INDOOR COIL, SUITABLE FOR USE IN COOLING ONLY AND HEAT PUMP SYSTEMS.

FEATURES
Room thermostat Exceptional installation flexibility - the indoor unit can be installed in three air flow positions: upwards, downwards or horizontal. Refrigerant circuit service valves with easily accessible pressure test ports for start-up and maintenance. Heat pump cycle with four-position valve (38EYX); electronic control system for optimised defrosting. Single split: 38EYX

OUTDOOR UNITS

High and low-pressure safety switches fitted as standard.

ACCESSORIES
Downflow convertion kit. Downflow/horizontal kit. Filter kit.

To ensure long life and reliability, outdoor unit compressors are hermetically sealed against contamination and pollutants.

58

Fixed speed split systems

Heat Pump systems Cooling capacity Power input E.E.R. Energy efficiency class Annual Energy Consumption Heating capacity Power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (HxWxD) Weight Outdoor unit Compressor type Maximum pipe length Maximum height difference Pre-charged length Flare connections (Gas-Liquid) Air flow Sound pressure Sound power Dimensions (HxLxD) Weight Maximum running current Power supply

Size kW W W/W kWh kW W W/W

48 13,66 4360 n.a. 3,13 n.a. 14,48 3820 3,79 n.a. FX4CSX048 7 750 125 77 61 1261x537x560 72 38EYX048-X-9 scroll 50 45 (*) 4,5 3/8 - 7/8 5098 72 52 1015x762x762 99,3 12 400 / 3 / 50

60 16,73 5870 n.a. 2,85 n.a. 17,07 5040 3,39 n.a. FX4CSX060 8,2 825 125 80 64 1357x537x560 80 38EYX060-X-9 scroll 50 45 (*) 4,5 3/8 - 7/8 4248 74 54 862x762x762 111,6 14 400 / 3 / 50

Model l/h l/s Pa dB(A) dB(A) mm kg Model m m m CO CO CO CO CO CO/HP CO/HP m3/h dB(A) dB(A) mm kg A V-ph-Hz

59

FB4X

38TYG - DUcTED cDU

CONTROLS

These split satellite systems have an innovative condensing units that can be mounted indoor and represent a breakthrough in the way to intend a light commercial application. 38TYG is the new series of ductable condensing units, the ideal solution for preserving building aesthetics. FEATURES

Zone manager

Room controller R410A heat pumps; 6 capacity points, from 5kW to 14kW.

INDOOR UNIT

Ease-of-installation and ease-of-service: different options for air inlet and outlet for flexible installation with ducts; access to key components is from two sides. Up to 80Pa static pressure for the condensing unit, as well as for the indoor satellite.

40DMC

ACCESSORIES
Low ambient kit

Rust resistant and cabinet protection for outdoor installation.

6 sizes, from 5kW to 14kW, single and three phases.

60

Fixed speed split systems

Heat Pump systems Cooling capacity Power input E.E.R. Energy efficiency class Annual Energy Consumption Heating capacity Power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Chargeless Static pressure Flare connections Air flow (at 0 Pa) Sound pressure Sound power Dimensions (h l d) Weight Power supply Operating range (min. max.) Operating range (min. max.) Outdoor unit (HP) Low ambient Operating range (min. max.) Operating range (min. max.) CO/HP CO/HP CO/HP CO CO CO/HP CO/HP CO/HP HP CO

Size kW W W/W

50 4,90 1740 2,82 C

70 7,00 2490 2,81 C 3500 7,00 2180 3,21 C 40DMC036S 1,8 400 / 300 / 220 50 48 / 46 / 43 61 / 59 / 56

85 8,50 3030 2,81 C 4250 8,00 2850 2,81 D 40NYD085 1,5 463 / 380 / 291 50 49 / 46 / 44 64 / 59 / 57

100 9,82 3500 2,81 C 4910 9,61 3400 2,83 D 40NYD085 2,3 463 / 380 / 291 50 49 / 46 / 44 64 / 59 / 57

100 10,00 3550 2,81 C 5000 9,74 3284 2,96 D 40NYD085 2,3 463 / 380 / 291 50 49 / 46 / 44 64 / 59 / 57

120 11,55 3800 3,04 B 5775 11,80 3260 3,62 A 40NYD100 3,0 667 / 616 / 569 80 54 / 51 / 47 67 / 64 / 60

140 13,49 4800 2,81 C 6733 14,70 4460 3,30 B 40NYD130 3,0 667 / 616 / 569 80 54 / 51 / 47 67 / 64 / 60

kWh kW W W/W

2450 4,90 1710 3,22 C

Model l/h l/s Pa dB(A) dB(A) mm kg V-ph-Hz

40DMC024 1,6 269 / 211 / 205 50 42 / 40 / 38 55 / 53 / 51

925 290 750 925 290 750 1325 290 750 1325 290 750 1325 290 750 1325 290 750 1325 290 750 35 230-1-50 38TY-050H7 rotary 36 230-1-50 38TY-070H7 scroll 30 15 8 80 5/8 3/8 (*) 2430 56 70 48 230-1-50 38TY-085H7 scroll 30 15 8 80 5/8 3/8 (*) 3596 59 73 48 230-1-50 38TY-100H7 scroll 30 15 8 80 3/4 3/8 3596 59 73 48 230-1-50 38TY-100H9 scroll 30 15 8 80 3/4 3/8 3596 59 73 53 230-1-50 38TY-120H9 scroll 30 15 8 80 3/4 3/8 4672 61 75 53 230-1-50 38TY-140H9 scroll 30 15 8 80 3/4 3/8 4672 61 75

m m m Pa

30 15 8 60 1/2 1/4

m3/h dB(A) dB(A) mm kg V-ph-Hz C C

1835 53 67

1200 395 750 1200 395 750 1400 440 830 1400 440 830 1400 440 830 1400 440 830 1400 440 830 93 230-1-50 21 46 8 24 38TYP050H7 95 230-1-50 21 46 15 24 38TYP070H7 15 46 15 24 122 230-1-50 21 46 15 24 38TYP085H7 15 46 15 24 122 230-1-50 21 46 15 24 38TYP100H7 15 46 15 24 122 400-3-50 21 46 15 24 38TYP100H9 15 46 15 24 132 400-3-50 21 46 15 24 38TYP120H9 15 46 15 24 132 400-3-50 21 46 15 24 38TYP140H9 15 46 15 24

C C

15 46 8 24

* 3/4 to 5/8 adapter will be supplied in outdoor unit 38TY-070H7,38TY-085H7 liquid line between units will be 5/8

61

38TYG

MULTIspLIT sYsTEms

CONTROLS

THIS INVERTER MULTISPLIT RANGE MULTIPLIES THE XPOWER ADVANTAGES, ALLOWING SEVERAL ROOMS TO BE AIR CONDITIONED AT LOW COST.
Room controller

Zone manager

FEATURES
DC Inverter Technology, Twin Rotary cylinders: high performance and savings. Long pipe runs: the pipe can reach up to 15m in height and 70m in length, making the installation simpler and quicker. Self-diagnosis system: with 40 different check codes, the diagnostic process is both precise and effective. Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit. Chargeless: the refrigerant charge is suitable for any combination; no additional charge is needed. 40SQM 42ADF Corrosion-resistant base and cabinet, made with UV-resistant polymer materials.

Infrared

Infrared (only for 42NQV_MM)

INDOOR UNITS

42NQV_MM

Advanced electronic management. 40KQM 42VQM

ACCESSORIES
Wall brackets

62

Inverter multisplit systems

Compatibility Chart
Heat Pump / Cooling only Outdoor unit 7 Hi-Wall 42NQV_MM 9 12 15 9 Diamond 42ADF 38VYM-14N 38VGM-14N 38VYM-18N 38VGM-18N 38VYM-28N 38VGM-28N 38VYM-32N 38VGM-32N

12

9 Console/Underceiling 42VQM 12 15 9 Satellite (Ducted) 40SQM 12 15 12 Cassette 40KQM 15

A wide choice of personal comfort


When it is necessary to air condition two, three or four rooms, the line-up of Carriers multi-split systems is the perfect solution. Carrier has enriched its Multisplit range to create all the comfort you desire.

2 rooms

3 rooms

4 rooms

63

38VGM_N/VYM_N

38VGM_N/VYM_N

Heat pump N. of compressors Compressor type Min. no. of connected indoor units Refrigerant charge Maximum pipe length per unit Minimum pipe length per unit Maximum height difference Total pipe length Total chargeless pipe length Flare connections (gas liquid) Air flow (l/m/h) Sound pressure Sound power Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) Operating range (min. max.) CO HP CO CO HP HP l/s dB(A) dB(A) dB(A) dB(A) mm kg A V-ph-Hz C C g m m m m m

38VYM-14N 1 Twin rotary 2 900 20 2 10 30 30 2 (3/8") 2 (1/4") 344/539/656 43 63 44 64 590 800 300 46 11,5 230-1-50 10 43 10 24

38VYM-18N 1 Twin rotary 2 1150 20 2 10 30 30 2 (3/8") 2 (1/4") 344/539/656 43 63 44 64 590 800 300 50 11,5 230-1-50 15 43 5 24

38VYM-28N 1 Twin rotary 2 2400 25 2 15 50 50 3 (3/8") 3 (1/4") 383/656/689 48 68 49 69 800 800 300 65 14,2 230-1-50 15 43 10 24

38VYM-32N 1 Twin rotary 2 2400 25 2 15 70 70 4 (3/8") 4 (1/4") 383/656/689 48 68 48 68 800 800 300 65 14,2 230-1-50 15 43 10 24

Cooling only N. of compressors Compressor type Min. no. of connected indoor units Refrigerant charge Maximum pipe length per unit Minimum pipe length per unit Maximum height difference Total pipe length Total chargeless pipe length Flare connections Air flow (l/m/h) Sound pressure Sound power Dimensions (h w d) Weight Maximum running current Power supply Operating range (min. max.) l/s dB(A) dB(A) mm kg A V-ph-Hz C g m m m m m

38VGM-14N 1 Twin rotary 2 900 20 2 10 30 30 2 (3/8") 2 (1/4") 344/539/656 45 65 590 800 300 46 11,5 230-1-50 10 43

38VGM-18N 1 Twin rotary 2 1150 20 2 10 30 30 2 (3/8") 2 (1/4") 344/539/656 43 63 590 800 300 50 11,5 230-1-50 10 43

38VGM-28N 1 Twin rotary 2 2400 25 2 15 50 50 3 (3/8") 3 (1/4") 383/656/689 48 68 800 800 300 65 14,2 230-1-50 10 43

38VGM-32N 1 Twin rotary 2 2400 25 2 15 70 70 4 (3/8") 4 (1/4") 383/656/689 48 68 800 800 300 65 14,2 230-1-50 10 43

64

Inverter multisplit systems

GOLD INVERTER Multi HI-WALL


Indoor unit Dehumidification Air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Flare connections (gas liquid) Power supply l/h l/s dB(A) dB(A) mm kg V-ph-Hz 42NQV007MM 1 86/105/115 26/33/38 37/44/49 275 790 205 9 1/4 3/8 220/240-1-50 42NQV009MM 1 86/123/149 26/33/38 37/44/49 275 790 205 9 1/4 3/8 220/240-1-50 42NQV012MM 1,4 86/123/156 26/33/39 37/44/50 275 790 205 9 1/4 3/8 220/240-1-50 42NQV015MM 1,6 103/144/192 30/40/45 41/51/56 275 790 205 9 1/4 1/2 220/240-1-50

DIAMOND INVERTER Multi HI-WALL

V-ph-Hz

42VQM INVERTER MULTI Console


Indoor unit Dehumidification Air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Flare connections Power supply l/h l/s dB(A) dB(A) mm kg V-ph-Hz 42VQM009 1,2 78/88/100 34/36/39 45/47/50 540 850 200 15 1/4 3/8 230-1-50 42VQM012 1,5 109/118/126 39/41/43 50/52/54 540 850 200 16 1/4 3/8 230-1-50 42VQM015 1,7 109/118/126 39/41/43 50/52/54 540 1000 200 18 1/4 1/2 230-1-50

40SQM INVERTER MULTI Satellite


Indoor unit Dehumidification Air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Flare connections Power supply l/h l/s dB(A) dB(A) mm kg V-ph-Hz 40SQM009 0,5 92/103/133 42/43/44 55/56/57 220 725 555 23 1/4 3/8 230-1-50 40SQM012 0,8 103/118/139 42/44/45 56/57/58 220 725 555 23 1/4 3/8 230-1-50 40SQM015 1 103/118/139 42/44/45 56/57/59 220 725 555 23 1/4 1/2 230-1-50

40KQM Inverter Multi Cassette


Indoor unit Dehumidification Air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Grille dimensions (h w d) Grille weight Flare connections Power supply l/h l/s dB(A) dB(A) mm kg mm kg V-ph-Hz 40KQM012 0,8 154/163/175 34/36/37 47/49/50 298/575/575 17,5 30/720/720 2,5 1/4 3/8 230-1-50 40KQM015 1 154/169/184 34/37/39 47/50/52 298/575/575 19 30/720/720 2,5 1/4 1/2 230-1-50

65

38VGM_N/VYM_N

Indoor unit Dehumidification Air flow (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h w d) Weight Flare connections (gas liquid) Power supply

l/h l/s dB(A) dB(A) mm kg

42ADF025M 1,1 92/108/124 33/37/39 47/51/53 820 390 185 14,6 1/4 3/8 230-1-50

42ADF035M 1,3 101/116/132 35/38/41 49/52/54 820 390 185 14,6 1/4 3/8 230-1-50

38VGM_N/VYM_N
Coding for 42ADF is different, please consider size 25=9 and size 35=12

38VGM_N/VYM_N (DUAL SPLIT)


Cooling mode (size 14) Indoor unit size 7 9 12 7+7 7+9 7 + 12 9+9 9 + 12 Cooling mode (size 18) Indoor unit size 7 9 12 15 7+7 7+9 7 + 12 7 + 15 9+9 9 + 12 12 + 12 9 + 15 Total 2,60 2,98 3,46 3,87 4,90 4,95 5,00 5,05 5,08 5,09 5,12 5,15 Min 1,10 1,10 1,10 1,10 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 Max 3,21 3,40 3,80 4,00 5,60 5,60 5,60 5,60 5,60 5,60 5,60 5,60 Cooling Capacity (kW) IU #1 2,60 2,98 3,46 3,87 2,45 2,17 1,77 1,61 2,54 3,05 2,56 1,93 IU #2 2,45 2,78 3,23 3,44 2,54 2,04 2,56 3,22 IU #3 IU #4 Total 760 900 1150 1350 1625 1630 1650 1680 1690 1680 1690 1710 Input Power (W) Min 290 290 290 290 250 250 250 250 250 250 250 250 Max 1060 1060 1300 1380 2040 2040 2040 2040 2040 2040 2040 2040 EER W/W 3,42 3,31 3,01 2,87 3,02 3,04 3,03 3,01 3,01 3,03 3,03 3,01 A A B C B B B B B B B B Energy Class AEC kW/h 380 450 575 675 813 815 825 840 845 840 845 855 Total 2,31 2,48 2,62 3,76 3,80 3,85 3,90 3,95 Min 1,10 1,10 1,10 1,40 1,40 1,40 1,40 1,40 Max 3,00 3,40 3,40 5,20 5,20 5,40 5,40 5,60 Cooling Capacity (kW) IU #1 2,31 2,48 2,62 1,88 1,66 1,42 1,95 1,69 IU #2 1,88 2,14 2,43 1,95 2,26 IU #3 IU #4 Total 610 680 780 1160 1170 1180 1190 1210 Input Power (W) Min 290 290 290 250 250 250 250 250 Max 1060 1100 1300 1960 1980 2000 2000 2040 EER W/W 3,79 3,65 3,36 3,24 3,25 3,26 3,28 3,26 A A A A A A A A Energy Class AEC kW/h 305 340 390 580 585 590 595 605

38VGM_N/VYM_N (TRI SPLIT)


Cooling mode (size 28) Indoor unit size 7 9 12 15 7+7 7+9 7 + 12 7 + 15 9+9 9 + 12 9 + 15 12 + 12 12 + 15 15 + 15 7+7+7 7+7+9 7 + 7 + 12 7 + 7 + 15 7 + 9 + 12 7 + 9 + 15 7 + 12 + 15 7+9+9 7 + 12 + 12 7 + 15 + 15 9+9+9 9 + 9 + 12 9 + 12 + 12 9 + 12 + 15 12 + 12 + 12 9 + 15 + 15 12 + 12 + 15 12 + 15 + 15 Total 2,40 2,47 3,21 4,23 4,50 4,60 4,70 5,15 4,79 5,15 5,60 5,76 6,05 6,10 6,20 6,30 6,45 6,45 6,45 6,47 6,47 6,45 6,46 6,49 6,45 6,47 6,49 6,49 6,51 6,60 6,63 6,66 Min 1,10 1,20 1,20 1,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 Max 3,21 2,90 3,80 4,50 5,55 5,55 5,55 5,95 5,55 5,95 6,20 6,20 6,20 6,20 6,90 6,90 7,20 7,20 7,20 7,30 7,30 7,20 7,30 7,40 7,20 7,30 7,40 7,40 7,50 7,50 7,50 7,50 Cooling Capacity (kW) IU #1 2,47 2,45 3,21 4,23 2,25 2,01 1,73 1,64 2,35 2,06 2,10 2,88 2,69 3,05 2,07 1,92 1,74 1,56 1,61 1,46 1,33 1,81 1,46 1,23 2,15 1,94 1,82 1,62 2,17 1,52 2,04 1,90 IU #2 2,25 2,59 2,97 3,51 2,35 3,09 3,50 2,88 3,36 3,05 2,07 1,92 1,74 1,56 2,07 1,88 2,28 2,32 2,50 2,63 2,15 1,94 2,34 2,16 2,17 2,54 2,04 2,38 IU #3 2,07 2,46 2,97 3,33 2,77 3,13 2,86 2,32 2,50 2,63 2,15 2,59 2,34 2,71 2,17 2,54 2,55 2,38 IU #4 Total 740 745 1060 1400 1415 1420 1420 1700 1480 1700 1850 1910 2010 2020 2020 2040 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2100 2110 2150 Input Power (W) Min 290 600 600 600 620 620 620 620 620 620 620 620 620 620 620 620 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 Max 1060 1100 1370 1630 1900 1900 1900 2100 1900 2100 2300 2300 2300 2300 2440 2440 2550 2550 2550 2580 2580 2550 2580 2650 2550 2580 2650 2650 2650 2650 2650 2650 EER W/W 3,24 3,32 3,03 3,02 3,18 3,24 3,31 3,03 3,24 3,03 3,03 3,02 3,01 3,02 3,07 3,09 3,13 3,13 3,13 3,14 3,14 3,13 3,14 3,15 3,13 3,14 3,15 3,15 3,16 3,14 3,14 3,10 A A B B B A A B A B B B B B B B B B B B B B B B B B B B B B B B Energy Class AEC kW/h 370 373 530 700 708 710 710 850 740 850 925 955 1005 1010 1010 1020 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1050 1055 1075

66

Inverter multisplit systems

38VGM_N/VYM_N (QUADRI SPLIT)


Cooling mode (size 32) Indoor unit size 7 9 12 15 7+7 7+9 7 + 12 7 + 15 9+9 9 + 12 9 + 15 12 + 12 12 + 15 15 + 15 7+7+7 7+7+9 7 + 7 + 12 7 + 7 + 15 7 + 9 + 12 7 + 9 + 15 7 + 12 + 15 7+9+9 7 + 12 + 12 7 + 15 + 15 9+9+9 9 + 9 + 12 9 + 12 + 12 9 + 12 + 15 12 + 12 + 12 9 + 15 + 15 12 + 12 + 15 12 + 15 + 15 7+7+7+7 7+7+7+9 7 + 7 + 7 + 12 7 + 7 + 7 + 15 7+9+9+9 7+7+9+9 7 + 7 + 12 + 12 7 + 7 + 15 + 15 7 + 7 + 9 + 12 7 + 7 + 9 + 15 7 + 7 + 12 + 15 7 + 9 + 12 + 15 7 + 9 + 15 + 15 7 + 12 + 9 + 9 7 + 15 + 9 + 9 7 + 12 + 12 + 12 7 + 12 + 12 + 15 9+9+9+9 9 + 9 + 9 + 15 9 + 9 + 9 + 12 9 + 9 + 12 + 12 9 + 9 + 12 + 15 9 + 12 + 12 + 12 9 + 12 + 12 + 15 12 + 12 + 12 + 12 9 + 9 + 15 + 15 Total 2,40 2,47 3,21 4,23 4,50 4,60 4,70 5,15 4,79 5,15 5,60 5,76 6,05 6,10 6,20 6,30 6,45 6,45 6,45 6,47 6,47 6,45 6,46 6,49 6,45 6,47 6,49 6,49 6,51 6,60 6,63 6,66 7,10 7,15 7,20 7,25 7,25 7,24 7,30 7,40 7,30 7,35 7,35 7,41 7,50 7,30 7,35 7,45 7,50 7,30 7,40 7,35 7,41 7,50 7,50 7,68 7,65 7,68 Min 1,10 1,20 1,20 1,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 2,20 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 4,20 Max 3,21 2,90 3,80 4,50 5,55 5,55 5,55 5,95 5,55 5,95 6,20 6,20 6,20 6,20 6,90 6,90 7,20 7,20 7,20 7,30 7,30 7,20 7,30 7,40 7,20 7,30 7,40 7,40 7,50 7,50 7,50 7,50 7,90 7,90 7,90 7,90 7,90 7,90 8,00 8,00 7,90 8,00 8,05 8,10 8,20 8,00 8,00 8,10 8,20 8,00 8,05 8,05 8,10 8,20 8,20 8,20 8,30 8,30 Cooling Capacity (kW) IU #1 2,47 2,45 3,21 4,23 2,25 2,01 1,73 1,64 2,35 2,06 2,10 2,88 2,69 3,05 2,07 1,92 1,74 1,56 1,61 1,46 1,33 1,81 1,46 1,23 2,15 1,94 1,82 1,62 2,17 1,52 2,04 1,90 1,77 1,67 1,53 1,41 1,49 1,58 1,35 1,24 1,35 1,35 1,26 1,21 1,13 1,38 1,29 1,21 1,52 1,83 1,59 1,69 1,48 1,50 1,43 1,44 1,91 1,44 IU #2 2,25 2,59 2,97 3,51 2,35 3,09 3,50 2,88 3,36 3,05 2,07 1,92 1,74 1,56 2,07 1,88 2,28 2,32 2,50 2,63 2,15 1,94 2,34 2,16 2,17 2,54 2,04 2,38 1,77 1,67 1,53 1,41 1,92 1,58 1,35 1,24 1,35 1,35 1,26 1,55 1,47 2,36 2,76 2,08 1,96 1,83 1,59 1,69 1,48 1,50 2,03 1,92 1,91 1,44 IU #3 2,07 2,46 2,97 3,33 2,77 3,13 2,86 2,32 2,50 2,63 2,15 2,59 2,34 2,71 2,17 2,54 2,55 2,38 1,78 1,67 1,53 1,41 1,92 2,04 2,30 2,46 1,73 1,74 2,15 2,07 2,45 1,78 1,65 2,08 1,96 1,83 1,59 1,69 2,22 2,00 2,03 1,92 1,91 2,40 IU #4 1,78 2,15 2,61 3,02 1,92 2,04 2,30 2,46 2,87 2,91 2,68 2,58 2,45 1,78 1,65 2,08 3,26 1,83 2,63 2,28 2,22 2,50 2,03 2,40 1,91 2,40 Total 740 745 1060 1400 1415 1420 1420 1700 1480 1700 1850 1910 2010 2020 2020 2040 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2100 2110 2150 2255 2255 2260 2265 2265 2265 2270 2300 2270 2270 2290 2310 2340 2270 2270 2340 2340 2270 2290 2290 2300 2320 2330 2370 2370 2370 Input Power (W) Min 290 600 600 600 620 620 620 620 620 620 620 620 620 620 620 620 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 930 Max 1060 1100 1370 1630 1900 1900 1900 2100 1900 2100 2300 2300 2300 2300 2440 2440 2550 2550 2550 2580 2580 2550 2580 2650 2550 2580 2650 2650 2650 2650 2650 2650 2700 2700 2750 2750 2750 2750 2800 2800 2750 2750 2800 2800 2800 2800 2800 2800 2800 2700 2700 2700 2750 2800 2800 2800 2850 2850 EER W/W 3,24 3,32 3,03 3,02 3,18 3,24 3,31 3,03 3,24 3,03 3,03 3,02 3,01 3,02 3,07 3,09 3,13 3,13 3,13 3,14 3,14 3,13 3,14 3,15 3,13 3,14 3,15 3,15 3,16 3,14 3,14 3,10 3,15 3,17 3,19 3,20 3,20 3,20 3,22 3,22 3,22 3,24 3,21 3,21 3,21 3,22 3,24 3,18 3,21 3,22 3,23 3,21 3,22 3,23 3,22 3,24 3,23 3,24 A A B B B A A B A B B B B B B B B B B B B B B B B B B B B B B B B B B B B B A A A A A A A A A B A A A A A A A A A A Energy Class AEC kW/h 370 373 530 700 708 710 710 850 740 850 925 955 1010 1010 1020 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1030 1050 1055 1075 1128 1128 1130 1133 1133 1133 1135 1150 1135 1135 1145 1155 1170 1135 1135 1170 1170 1135 1145 1145 1150 1160 1165 1185 1185 1185

67

38VGM_N/VYM_N

1005

38VYM_N
Coding for 42ADF is different, please consider size 25=9 and size 35=12

38VYM_N (DUAL SPLIT)


Heating mode (size 14) Indoor unit size 7 9 12 7+7 7+9 7 + 12 9+9 9 + 12 Heating mode (size 18) Indoor unit size 7 9 12 15 7+7 7+9 7 + 12 7 + 15 9+9 9 + 12 12 + 12 9 + 15 Total 3,12 3,64 4,18 4,25 5,20 5,30 5,40 5,50 5,60 5,65 5,70 5,75 Min 0,70 0,70 0,70 0,70 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 Max 4,20 4,20 4,50 4,50 6,10 6,10 6,20 6,20 6,20 6,20 6,20 6,20 Heating Capacity (kW) IU #1 3,12 3,64 4,18 4,25 2,60 2,32 1,99 1,75 2,80 3,39 2,85 2,16 IU #2 2,60 2,98 3,41 3,75 2,80 2,26 2,85 3,59 IU #3 IU #4 Total 1095 1380 1540 1580 1620 1650 1660 1670 1670 1630 1660 1660 Input Power (W) Min 160 160 160 160 160 160 160 160 160 160 160 160 Max 1470 1470 1600 1600 2100 2100 2300 2300 2300 2300 2300 2300 COP W/W 2,85 2,64 2,71 2,69 3,21 3,21 3,25 3,29 3,35 3,47 3,43 3,46 D E E E C C C C C B B B Energy Class Total 2,44 2,70 2,90 3,40 3,46 3,46 3,46 3,55 Min 0,70 0,70 0,70 0,90 0,90 0,90 0,90 0,90 Max 3,20 3,60 4,00 4,20 4,20 4,40 4,40 4,50 Heating Capacity (kW) IU #1 2,44 2,70 2,90 1,70 1,51 1,27 1,73 1,52 IU #2 1,70 1,95 2,19 1,73 2,03 IU #3 IU #4 Total 710 740 780 820 830 840 860 880 Input Power (W) Min 160 160 160 160 160 160 160 160 Max 1200 1250 1250 1420 1420 1500 1500 1500 COP W/W 3,44 3,65 3,72 4,15 4,16 4,12 4,03 4,03 B A A A A A A A Energy Class

38VYM_N (TRI SPLIT)


Heating mode (size 28) Indoor unit size 7 9 12 15 7+7 7+9 7 + 12 7 + 15 9+9 9 + 12 9 + 15 12 + 12 12 + 15 15 + 15 7+7+7 7+7+9 7 + 7 + 12 7 + 7 + 15 7 + 9 + 12 7 + 9 + 15 7 + 12 + 15 7+9+9 7 + 12 + 12 7 + 15 + 15 9+9+9 9 + 9 + 12 9 + 12 + 12 9 + 12 + 15 12 + 12 + 12 9 + 15 + 15 12 + 12 + 15 12 + 15 + 15 Total 3,35 3,40 4,40 4,70 6,15 6,30 6,55 6,85 6,55 6,85 6,90 7,00 7,30 7,50 7,80 7,90 8,05 8,05 8,05 8,15 8,15 8,05 8,15 8,15 8,05 8,15 8,25 8,25 8,40 8,45 8,50 8,55 Min 1,10 1,10 1,10 1,20 2,20 2,20 1,40 1,40 1,40 1,40 2,20 1,40 2,20 2,20 3,50 3,50 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 3,50 3,50 3,50 Max 3,50 4,00 5,00 5,40 8,60 8,60 8,80 8,80 9,00 9,00 9,20 9,20 9,20 9,20 9,20 9,20 9,40 9,40 9,40 9,50 9,50 9,40 9,50 9,50 9,40 9,50 9,60 9,60 9,70 9,40 9,40 9,70 Heating Capacity (kW) IU #1 3,35 3,40 4,40 4,70 3,08 2,76 2,41 2,18 3,28 4,11 2,59 3,50 3,24 3,75 2,60 2,40 2,17 1,94 2,01 1,84 1,68 2,25 1,85 1,55 2,68 2,45 2,31 2,06 2,80 1,95 2,62 2,45 IU #2 3,08 3,54 4,14 4,67 3,28 2,74 4,31 3,50 4,06 3,75 2,60 2,40 2,17 1,94 2,59 2,37 2,88 2,90 3,15 3,30 2,68 2,45 2,97 2,75 2,80 3,25 2,62 3,05 IU #3 2,60 3,10 3,71 4,17 3,45 3,94 3,59 2,90 3,15 3,30 2,68 3,26 2,97 3,44 2,80 3,25 3,26 3,05 IU #4 Total 1430 1440 1940 2050 2350 2380 2400 2400 2400 2400 2400 2400 2450 2450 2380 2390 2400 2400 2410 2420 2420 2430 2430 2380 2360 2330 2360 2360 2400 2450 2470 2500 Input Power (W) Min 290 300 350 600 620 620 450 450 450 450 620 450 620 620 900 900 530 530 530 530 530 530 530 530 530 530 530 530 530 900 900 900 Max 1500 1550 2000 2100 2950 2950 3000 3050 3000 3050 3000 3000 3000 3000 3000 3000 2800 2800 2800 2800 2800 2800 2800 2800 2800 2800 2840 2840 2900 2800 2800 2800 COP W/W 2,34 2,36 2,27 2,29 2,62 2,65 2,73 2,85 2,73 2,85 2,88 2,92 2,98 3,06 3,28 3,31 3,35 3,35 3,34 3,37 3,37 3,31 3,35 3,42 3,41 3,50 3,50 3,50 3,50 3,45 3,44 3,42 G G G G E E E D E D D D D D C C C C C C C C C B B B B B B B B B Energy Class

68

Inverter multisplit systems

38VYM_N (QUADRI SPLIT)


Heating mode (size 32) Indoor unit size 7 9 12 15 7+7 7+9 7 + 12 7 + 15 9+9 9 + 12 9 + 15 12 + 12 12 + 15 15 + 15 7+7+7 7+7+9 7 + 7 + 12 7 + 7 + 15 7 + 9 + 12 7 + 9 + 15 7 + 12 + 15 7+9+9 7 + 12 + 12 7 + 15 + 15 9+9+9 9 + 9 + 12 9 + 12 + 12 9 + 12 + 15 12 + 12 + 12 9 + 15 + 15 12 + 12 + 15 12 + 15 + 15 7+7+7+7 7+7+7+9 7 + 7 + 7 + 12 7 + 7 + 7 + 15 7+9+9+9 7+7+9+9 7 + 7 + 12 + 12 7 + 7 + 15 + 15 7 + 7 + 9 + 12 7 + 7 + 9 + 15 7 + 7 + 12 + 15 7 + 9 + 12 + 15 7 + 9 + 15 + 15 7 + 12 + 9 + 9 7 + 15 + 9 + 9 7 + 12 + 12 + 12 7 + 12 + 12 + 15 9+9+9+9 9 + 9 + 9 + 15 9 + 9 + 9 + 12 9 + 9 + 12 + 12 9 + 9 + 12 + 15 9 + 12 + 12 + 12 9 + 12 + 12 + 15 12 + 12 + 12 + 12 9 + 9 + 15 + 15 Total 3,35 3,40 4,40 4,70 6,15 6,30 6,55 6,85 6,55 6,85 6,90 7,00 7,30 7,50 7,80 7,90 8,05 8,05 8,05 8,15 8,15 8,05 8,15 8,15 8,05 8,15 8,25 8,25 8,40 8,45 8,50 8,55 8,20 8,22 8,25 8,28 8,35 8,30 8,46 8,50 8,42 8,45 8,48 8,50 8,60 8,45 8,50 8,55 8,65 8,45 8,50 8,50 8,55 8,60 8,60 8,70 8,70 8,60 Min 1,10 1,10 1,10 1,20 2,20 2,20 1,40 1,40 1,40 1,40 2,20 1,40 2,20 2,20 3,50 3,50 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 1,90 3,50 3,50 3,50 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,10 2,60 2,60 2,10 Max 3,50 4,00 5,00 5,40 8,60 8,60 8,80 8,80 9,00 9,00 9,20 9,20 9,20 9,20 9,20 9,20 9,40 9,40 9,40 9,50 9,50 9,40 9,50 9,50 9,40 9,50 9,60 9,60 9,70 9,40 9,40 9,70 9,50 9,50 9,50 9,50 9,80 9,80 9,80 9,80 9,80 9,80 9,80 9,80 10,10 9,80 9,90 10,00 10,10 9,80 9,90 9,90 10,00 10,10 10,10 10,20 10,20 10,10 Heating Capacity (kW) IU #1 3,35 3,40 4,40 4,70 3,08 2,76 2,41 2,18 3,28 4,11 2,59 3,50 3,24 3,75 2,60 2,40 2,17 1,94 2,01 1,84 1,68 2,25 1,85 1,55 2,68 2,45 2,31 2,06 2,80 1,95 2,62 2,45 2,05 1,92 1,75 1,61 1,72 1,82 1,56 1,42 1,68 1,56 1,45 1,38 1,31 1,59 1,49 1,38 1,32 2,11 1,82 1,96 1,71 1,72 1,63 1,62 2,18 1,61 IU #2 3,08 3,54 4,14 4,67 3,28 2,74 4,31 3,50 4,06 3,75 2,60 2,40 2,17 1,94 2,59 2,37 2,88 2,90 3,15 3,30 2,68 2,45 2,97 2,75 2,80 3,25 2,62 3,05 2,05 1,92 1,75 1,61 2,21 1,82 1,56 1,42 1,68 1,56 1,45 1,78 1,69 2,74 3,19 2,39 2,26 2,11 1,82 1,96 1,71 1,72 2,32 2,18 2,18 1,61 IU #3 2,60 3,10 3,71 4,17 3,45 3,94 3,59 2,90 3,15 3,30 2,68 3,26 2,97 3,44 2,80 3,25 3,26 3,05 2,05 1,92 1,75 1,61 2,21 2,33 2,67 2,83 2,17 2,00 2,48 2,37 2,80 2,06 1,91 2,39 2,26 2,11 1,82 1,96 2,57 2,29 2,32 2,18 2,18 2,69 IU #4 2,05 2,46 3,00 3,45 2,21 2,33 2,67 2,83 2,89 3,33 3,10 2,97 2,80 2,06 1,91 2,39 2,81 2,11 3,04 2,64 2,57 2,87 2,32 2,72 2,18 2,69 Total 1430 1440 1940 2050 2350 2380 2400 2400 2400 2400 2400 2400 2450 2450 2380 2390 2400 2400 2410 2420 2420 2430 2430 2380 2360 2330 2360 2360 2400 2450 2470 2500 2240 2240 2250 2260 2280 2280 2280 2280 2280 2280 2280 2290 2320 2280 2320 2340 2350 2280 2300 2300 2310 2310 2310 2310 2320 2320 Input Power (W) Min 290 300 350 600 620 620 450 450 450 450 620 450 620 620 900 900 530 530 530 530 530 530 530 530 530 530 530 530 530 900 900 900 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 Max 1500 1550 2000 2100 2950 2950 3000 3050 3000 3050 3000 3000 3000 3000 3000 3000 2800 2800 2800 2800 2800 2800 2800 2800 2800 2800 2840 2840 2900 2800 2800 2800 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2920 2900 2900 2910 2920 2900 2900 2900 2910 2920 2920 2930 2930 2920 COP W/W 2,34 2,36 2,27 2,29 2,62 2,65 2,73 2,85 2,73 2,85 2,88 2,92 2,98 3,06 3,28 3,31 3,35 3,35 3,34 3,37 3,37 3,31 3,35 3,42 3,41 3,50 3,50 3,50 3,50 3,45 3,44 3,42 3,66 3,67 3,67 3,66 3,66 3,64 3,71 3,73 3,69 3,71 3,72 3,71 3,71 3,71 3,66 3,65 3,68 3,71 3,70 3,70 3,70 3,72 3,72 3,77 3,75 3,71 G G G G E E E D E D D D D D C C C C C C C C C B B B B B B B B B A A A A A A A A A A A A A A A A A A A A A A A A A A Energy Class

69

38VYM_N

MULTISPLIT SYSTEMS

CONTROLS

ULTRA-RELIABLE COMPRESSOR. IDEAL FOR BOTH RESIDENTIAL AND SMALL COMMERCIAL APPLICATIONS.

Modular control system

FEATURES
Design and components optimised for operation with R410A refrigerant.

INDOOR UNITS

42PHQ_S

42VMC

Rotary or scroll compressor, synonymous with high reliability and energy efficiency.

Exceptionally low noise fan.

40KMC

40SMC

New generation coil for optimised heat transfer.

Reduced unit size and weight make this one of the most compact units in its class on the market. 40DMC Low-ambient device guarantees efficient and safe operation, even at extremely low outside temperatures (to 15C for 38YY_M).

ACCESSORIES
Wall brackets

70

Fixed speed multisplit systems

Outdoor unit (CO) Compressor type Compressor Compressor Max no. of indoor units Maximum pipe length Maximum height difference Pre-charged length Additional charge Flare connections Flare connections Air flow Sound pressure Sound power Dimensions (h w d) Weight Starting current Power supply m m m g/m [A] [B] m/h dB(A) dB(A) mm kg A V-ph-Hz [A] [B]

38GL2M18H Rotary dedicated dedicated 2 15 + 15 5 8+8 15 3/8 1/4 3/8 1/4 1920 45 65 590 800 300 55 30 + 30 230-1-50

38GL2M24H Rotary dedicated dedicated 2 15 + 15 5 8+8 15 1/2 1/4 1/2 1/4 2470 51 71 590 800 300 64 30 + 30 230-1-50

38GL2M36G Rotary dedicated dedicated 2 30 + 30 10 8+8 15 1/2 1/4 1/2 1/4 1990 + 1990 49 69 1264 800 300 99 50 + 50 230-1-50

38GL2M48G Rotary dedicated dedicated 2 40 + 40 15 8+8 15 1/2 1/4 1/2 1/4 1990 + 1990 50 70 1264 800 300 102 60 + 60 230-1-50

38GL3M21H Rotary shared dedicated 3 15 + 15 5 8 + 15 15 3/8 1/4 1/2 1/4 3/8 1/4 1900 46 66 590 800 300 58 30 + 30 230-1-50

Outdoor unit (HP) Compressor type Compressor Compressor Max no. of indoor units Maximum pipe length Maximum height difference Pre-charged length Additional charge Flare connections Flare connections Air flow Sound pressure Sound power Dimensions (h w d) Weight Starting current Power supply m m m g/m [A] [B] m/h dB(A) dB(A) mm kg A V-ph-Hz [A] [B]

38YY2M24H Rotary dedicated dedicated 2 15 + 15 5 8+8 15 / 15 1/2 1/4 1/2 1/4 2720 48 68 803 800 300 64 30 + 30 230-1-50

38YY2M36G Rotary dedicated dedicated 2 30 + 30 15 8+8 20 / 20 1/2 1/4 1/2 1/4 1940 + 1940 49 69 1264 800 300 99 50 + 50 230-1-50

38YY2M48G Rotary dedicated dedicated 2 40 + 40 15 8+8 20 / 20 1/2 1/4 1/2 1/4 2320 + 2320 51 71 1264 800 300 102 60 + 60 230-1-50

71

38GL_M/YY_M

38GL_M/YY_M
PERFORMANCES 38GL_M
42PHQ-S 38GL2M18H Cooling capacity Power input (cooling mode) 09 + 09 E.E.R. Energy efficiency class (cooling mode) Annual energy consumption (cooling mode) 38GL2M24H Cooling capacity Power input (cooling mode) 12 + 12 E.E.R. Energy efficiency class (cooling mode) Annual energy consumption (cooling mode) 38GL2M36G Cooling capacity Power input (cooling mode) 18 + 18 E.E.R. Energy efficiency class (cooling mode) Annual energy consumption (cooling mode) 38GL2M48G Cooling capacity Power input (cooling mode) 24 + 24 E.E.R. Energy efficiency class (cooling mode) Annual energy consumption (cooling mode) 38GL3M21H 09 + 09 + 09 Cooling capacity Power input (cooling mode) E.E.R. Energy efficiency class (cooling mode) Annual energy consumption (cooling mode) Cooling capacity Power input (cooling mode) 09 + 09 + 12 E.E.R. Energy efficiency class (cooling mode) Annual energy consumption (cooling mode) kWh kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kW W W/W 5,31 2170 2,45 E 1085 6,15 2650 2,32 F 1325 10,46 4050 2,58 E 2025 12,60 5220 2,41 n.a. 2610 5,86 2360 2,48 E 1180 5,97 2380 2,51 E 1190 42VMC-N 4,90 2080 2,36 F 1040 6,04 2610 2,31 F 1305 10,28 3970 2,59 E 1985 12,80 5320 2,41 n.a. 2660 5,82 2360 2,47 E 1180 5,86 2380 2,46 E 1190 40KMC-N 6,28 2730 2,30 F 1365 10,74 3990 2,69 D 1995 13,20 5300 2,49 n.a. 2650 40SMC-N 5,40 2730 1,98 G 1365 6,13 2910 2,11 G 1455 9,45 4160 2,27 F 2080 12,50 5410 2,31 n.a. 2705 5,92 2620 2,26 F 1310 5,96 2640 2,26 F 1320 40DMC 10,02 3890 2,58 E 1945 13,00 5500 2,36 n.a. 2750 -

INDOOR UNITS COMBINATION


Indoor units 38GL2M18H 38GL2M24H 38GL2M36G 38GL2M48G 09 + 09 12 + 12 18 + 18 24 + 24 09 9 12 38GL3M21H 09 + 09 12 + 09 09 + 09 09 + 09 + 09 09 + 12 + 09 Data referred to combination with 42PHQ_P Circuit A 09 12 18 24 09 12 09 12 09 + 09 09 + 09 09 + 12 Circuit B 09 12 18 24 09 09 09 09 09 Cooling Capacity (W) Total 5,31 6,15 10,46 12,60 2,89 2,32 2,97 5,17 5,25 3,58 5,86 5,90 1,79 1,78 1,78 Circuit A 2,66 3,08 5,23 6,30 2,89 2,97 2,87 2,95 1,79 1,78 1,82 Circuit B 2,66 3,08 5,23 6,30 2,32 2,30 2,30 2,30 2,30

72

Fixed speed multisplit systems

PERFORMANCES 38Y Y_M


42PHQ-S
38YY2M24H Cooling capacity Power input (cooling mode) E.E.R. Energy efficiency class (cooling mode) 12 + 12 Annual energy consumption (cooling mode) Heating capacity Power input (heating mode) C.O.P. Energy efficiency class (heating mode) 38YY2M36G 38YYS2M36G Cooling capacity Power input (cooling mode) E.E.R. Energy efficiency class (cooling mode) 18 + 18 Annual energy consumption (cooling mode) Heating capacity Power input (heating mode) C.O.P. Energy efficiency class (heating mode) 38YY2M48G 38YYS2M48G Cooling capacity Power input (cooling mode) E.E.R. Energy efficiency class (cooling mode) 24 + 24 Annual energy consumption (cooling mode) Heating capacity Power input (heating mode) C.O.P. Energy efficiency class (heating mode) kWh kW W W/W kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kW W W/W 6,80 2660 2,56 E 1330 7,05 2460 2,87 D 9,87 3770 2,62 D 1885 10,60 3490 3,04 D 12,10 4900 2,47 n.a. 2450 14,20 5220 2,72 n.a. 42VMC-N 6,50 2510 2,59 E 1255 6,80 2550 2,67 E 9,96 3890 2,56 E 1945 10,90 3650 2,99 D 13,00 5080 2,56 n.a. 2540 13,80 5360 2,57 n.a. 40KMC-N 6,62 2640 2,51 E 1320 6,96 2490 2,80 E 9,78 3850 2,54 E 1925 11,5 3650 3,15 D 12,7 4980 2,55 n.a. 2490 13,6 5400 2,52 n.a. 40SMC-N 6,12 2860 2,14 G 1430 6,50 2660 2,44 F 9,23 3960 2,33 F 1980 10,40 3930 2,65 E 12,08 4560 2,65 n.a. 2280 14,20 5000 2,84 n.a. 40DMC 9,95 3750 2,65

1875 10,80 3350 3,22 C 13,20 4920 2,68 n.a. 2460 14,20 4800 2,96 n.a.

DEDICATED COMPRESSOR

SHARED COMPRESSORS

For power To satisfy the needs of shops and offices, where maximium power is required simultaneously in more than one space, Carrier offers models with two dedicated compressors each serving one indoor unit, so that the power of each compressor is exploited to the full.

For economy Ideal to air-condition spaces where maximum conditioning power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed the multisplit with split compressor.

73

38GL_M/YY_M

CONTROL RANGE

MAIN FUNCTIONS: The basic and most used buttons are ergonomically placed for intuitive and user friendly operations. MY COMFORT: Allows selection and memorization of the favourite end-user setting via the remote control. EXTRA POWER: With this setting the fan will run at maximum speed and the setpoint will be reached quickly. IONIZER: The ionizer can be operated separately, to deliver millions of negative ions in the ambient and give an immediate sensation of well-being. Wall receiver for ducted satellite units Fixed speed and XPower inverter. ECONOMY: The unit will work at low speed for maximum energy saving and silent operation. LOUVRE CONTROL: Air flow direction can be remotely adjusted to optimized the air flow distribution and suit individual preferences. PROGRAMMING FUNCTION: Clock and 24 hours timer, sleep mode or continous programming settings are easily available. PRESET: Its possible to save the favourite combination of operating mode, temperature, setting, fan speed, auto fan speed and hi-power. SLEEP: During the night, the ideal temperature is maintained, granting high energy savings.

KIT FOR SATELLITE UNITS

74

Functions may vary depending on the unit

Direct expansion split systems

LOCAL WIRED CONTROL ROOM CONTROLLER 33MC

BUILDING MANAGEMENT ZONE MANAGER 33MC-ZM

WIRED CONTROL FOR SINGLE APPLICATIONS:


This small, elegant, wall-mounted control serves up to six units with the same settings.

SYSTEMS MONITORING:
This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones.

LIQUID CRYSTAL DISPLAY:


All settings and operation paremeters clearly displayed.

WEEKLY PROGRAMMING:
User can select four individual start/stop ranges per day of the week for each zone.

EASY MODE AND FAN SELECTION BUTTON:


Quick choice between cooling, heating, dehumidification, fan only or auto.

ZONE SETTINGS AND LOCAL OPERATION:


Any individual unit within each zone can be operated by the end-user according to his desires by overiding zone setting.

GROUPING FUNCTIONALITY:
This control is suitable to operate up to 6 units located in the same zone. (1 accessory usable for up to 5 slave units is required for proper installation of 33MC9002).

AUTONOMOUS OPERATION:
If power failure occurs, clock operations are maintained for up to 20 hours, while programmed parameters are kept in the memory.

75

CONTROL RANGE

40ALZ/ABZ-38XTZ/UQZ - SPLIT SYSTEM

CONTROLS
Unit connections to Carrier Comfort Zone II, VVT and TEMP systems (depending on the model).

Split-system air conditioners for cooling only (40ALZ/ABZ 38XTZ) and heat pump (40ALZ-38UQZ) applications. Consisting of indoor units (40ALZ/ABZ) and remote air-cooled outdoor units (38XTZ/UQZ). FEATURES
Outdoor unit fan motors with thermal protection.

ACCESSORIES/OPTIONS
Electric resistance heaters or hot-water coils. Low-pressure switch. Outdoor air thermostat for connection to the supplementary heating coil. Head pressure control for low outside temperature applications. Special drives for higher indoor unit fan static pressure. Room thermostat, wired remote control.

Wired remote control with accessory ambient thermostat.

Wide range of options such as crankcase heater (38XTZ) and, head-pressure control kit. Heat exchangers are made of high-quality copper tubing and pre-treated water-resistant aluminium fins. Master Link II electronic control with LEDs for simple service and maintenance. Hermetic reciprocating compressors include mufflers and mounted on shock absorbers.

76

DUCTABLE 40ALZ/ABZAIR-COOLED - 38XTZ/UQZ DUCTABLE AIR-COOLED


Physical data
Indoor unit 40ABZ/ALZ*** Outdoor unit 38XTZ Cooling capacity* Indoor unit 40ALZ Outdoor unit 38UQZ Cooling capacity* Heating capacity** Refrigerant Outdoor unit 38XTZ/38UQZ Weight Compressor Refrigerant-air heat exchanger Fan Quantity Nominal air flow Indoor unit 40ABZ/ALZ*** Weight Refrigerant-air heat exchanger Fan Nominal air flow kW 007 007 18.9 007 007 18.70 20.8 007 140/146 008 008 22.3 008 008 20.90 23.35 008 170/175 011*** 011 26.9 011 011 26.75 30.04 014*** 016 014 016 36.6 45.1 014 016 014 016 33.19 43,3 40.04 45,5 R-407C 011 014 016 200/246 300/355 450/480 Reciprocating, hermetic Copper tubes, aluminium fins Propeller 1 2 1 2500 4445 5850 011*** 014*** 016 160 236 290 Copper tubes, aluminium fins Two, double-inlet centrifugal 1777 2694 2820 020 020 52.3 020 020 53,5 57,5 020 488/555 024 024 68.4 024 024 67 78,4 024 503/590

DUCTABLE AIR-COOLED 40ALZ/ABZ - 38XTZ/UQZ

kW kW

kg

l/s kg

2 1805 007 135/140

2 1639 008 140/146

2 11.200 020 305

2 10.700 024 325

l/s

1416

1583

3120

3370

* Based on an outdoor air temperature of 35C db and an indoor air entering temperature of 19C wb and 27C db. ** Based on an outdoor air temperature of 6C wb and an indoor air entering temperature of 21C db. *** Sizes 011 and 014 are 40ALZ models for both the cooling only units and the heat pumps.

Electrical data (3 phase, 50 Hz)


38XTZ 40ABZ/ALZ Nominal supply 10% Nominal power input* Nominal current drawn* Starting current** 38UQZ-40ALZ Nominal supply 10% Nom. power input, cooling* Nom. power input, heating** Nom. current drawn, cooling* Nom. current drawn, heating** Starting current V kW A A V kW kW A A A 007 220 8.7 22.8 165 007 220 9.15 7.05 24.0 18.5 165 008 220 9.52 25.0 157 008 380-415 220 9.15 9.77 7.05 8.09 15.2 25.6 13.2 21.2 89 157 380-415 8.7 15.6 96 011*** 220 12.66 33.2 228 011 380-415 220 9.77 12.87 8.09 10.77 17.0 33.7 15.5 28.3 99 222 380-415 9.52 16.9 99 014*** 220 17.01 44.6 270 014 380-415 220 12.87 16.55 10.77 15.63 22.0 43.4 19.2 17.0 146 270 380-415 12.66 22.0 146 380-415 17.01 29.0 171 380-415 16.55 15.63 29.5 28.5 171 016 220 19.70 51.7 263 016 19,77 17,07 57,95 52,47 205,2 380-415 19.70 35.8 167 020 220 26.82 70.4 348 020 27,5 24,5 77,19 66,42 288,6 380-415 26.82 46.5 219 024 220 33.30 87.4 406 024 33,9 32 95,36 91,17 358,3 380-415 33.30 56.0 257

19,77 17,07 33,5 30,33 118,6

27,5 24,5 44,62 39,55 166,8

33,9 32 55,12 52,70 207,1

* Based on an outdoor air temperature of 35C db and an indoor air entering temperature of 19C wb and 27C db. ** Based on an outdoor air temperature of 6C wb and an indoor air entering temperature of 21C db. *** Sizes 011 and 014 are 40ALZ models for both the cooling only units and the heat pumps. Note: The power input of the optional/accessory electric resistance heaters (that can be installed in the unit) is not included.

Dimensions, mm
Model 40ABZ/ALZ 007- 011 40ALZ 014 40ABZ 016-020 40ABZ 024 Model 38XTZ/UQZ 007- 008 38XTZ 011 38UQZ 011 38XTZ/UQZ 014 38XTZ/UQZ 016-024 Length 1348 1588 2125 2625 Length 1328 1400 1700 2100 2000 Width 807 910 1080 1080 Width 528 950 950 975 1725 Height 662 788 680 680 Height 1565 910 10070 1015 1012

Note: Sizes 011 and 014 are 40ALZ models for both the cooling only units and the heat pumps.

64

77

40ALZ/ABZ-38XTZ/UQZ

50TZ/YZ - HORIZONTAL SPLIT COOLING

CONTROLS
Master Link II electronic control.

The 50TZ/YZ single-package cooling units and heat pumps are low-profile air-cooled units, designed for installation in the void above suspended ceilings. FEATURES
Master Link II electronic control with LEDs for simple service and maintenance.

ACCESSORIES/OPTIONS
Head pressure control. Electric heaters. Crankcase heater (50TZ only). Hot water coil. Flare connections. Outdoor air filter.

Interchangeable unit panels permit alternative supply and return air paths on all models. Reciprocating hermetic compressor includes over-current and overtemperature protection. Unit cabinet is made of pre-painted sheet steel for thermal and acoustic unit insulation.

Hidden condensing unit has no impact on building facades.

Quiet centrifugal fans, statically and dynamically balanced for vibrationfree operation.

78

UNITS/HEAT 50TZ/YZ - PUMPS


DUCTABLE AIR-COOLED
Physical data
50TZ Packaged unit Nominal cooling capacity* Weight Indoor unit Outdoor unit Weight (indoor unit) Weight (outdoor unit) 50YZ Packaged unit Nominal cooling capacity* Nominal heating capacity** Weight Indoor unit Outdoor unit Weight (indoor unit) Weight (outdoor unit) Compressor Refrigerant Indoor section (40TZ/BZ) Indoor fan (40TZ/BZ) Nominal air flow Outdoor section (38FZ/BZ) Outdoor fan (38FZ/BZ) Nominal air flow
* **

50TZ/YZ

kW kg

kg kg kW kW kg

kg kg

l/s

Based on an outdoor air dry bulb temperature of 350C and an indoor air wet bulb temperature of 190C. Based on an outdoor air wet bulb temperature of 60C and an indoor air dry bulb temperature of 200C.

Electrical data
50TZ (40TZ/BZ + 38FZ) Nominal voltage (10%)* Nominal power input** Nominal current drawn** Starting current 50YZ (40BZ + 38BZ) Nominal voltage (10%)* Nominal power input Cooling** Heating*** Nominal current drawn Cooling** Heating*** Starting current V kW A A V kW kW A A A 024 230 2.90 13.33 86 024 230 2.74 2.35 12.77 11.21 86 400 2.90 6.30 46 400 2.74 2.35 6.04 5.30 46 036 230 3.99 12.50 99 036 230 4.20 3.51 13.89 12.00 99 400 3.99 8.74 60 400 4.20 3.51 10.06 8.87 60 042 230 4.54 15.58 117 042 230 4.70 4.00 15.79 14.14 117 400 4.54 11.50 72 400 4.70 4.00 11.40 10.60 72 048 230 4.93 16.98 134 048 230 5.04 4.55 17.10 15.76 134 400 4.93 12.23 81 400 5.04 4.55 12.43 11.65 81 060 230 6.69 25.49 159 060 230 7.57 6.97 25.29 24.09 159 400 6.69 18.54 105 400 7.57 6.97 18.06 17.57 105 072 230 9.39 30.12 170 072 230 10.10 9.07 30.00 27.59 170 400 9.39 17.41 90 400 10.10 9.07 17.34 15.95 90 084 230 9.99 33.19 162 084 230 10.92 9.58 33.65 30.79 162 400 9.99 19.18 105 400 10.92 9.58 19.45 17.80 105

* The unit power supply is three-phase (except size 024, 230 V which is single-phase). The fan power supply is single-phase, except for sizes 072 and 084 which are three-phase. ** Based on an outdoor air dry bulb temperature of 350C and an indoor air wet bulb temperature of 190C and dry bulb temperature of 270C. *** Based on an outdoor air wet bulb temperature of 60C and an indoor air dry bulb temperature of 200C.

Dimensions, mm
50TZ/50YZ 024 036 042 048 060 072 084 38FZ/38BZ 024 036 042 048 060 072 084 Length 1190 1250 1350 1450 1500 1700 1700 Length 1190 1250 1350 1450 1500 1700 1700 Height 470 540 540 540 560 630 630 Height 470 540 540 540 560 630 630 Depth 1199 1259 1359 1459 1509 1709 1889 Depth 714 764 814 914 964 1008 1188 40TZ/BZ 024 036 042 048 060 072 084 Length 1190 1250 1350 1450 1500 1700 1700 Height 470 540 540 540 560 630 630 Depth 508 569 619 619 619 775 775

66

79

50TZ/YZ

l/s

024 036 042 6.50 9.11 10.50 168 193 211 40BZ 024 40BZ 036 40BZ 042 38FZ 024 38FZ 036 38FZ 042 58 63 71 110 130 140 024 036 042 6.20 8.90 10.10 6.52 9.50 11.30 170 196 214 40BZ 024 40BZ 036 40BZ 042 38BZ 024 38BZ 036 38BZ 042 58 63 71 112 133 143 Hermetic reciprocating compressor R-407C Copper tubes, pre-treated aluminium fins One ... centrifugal 400 565 670 Copper tubes, pre-treated aluminium fins One ... centrifugal 530 800 865

048 12.00 241 40BZ 048 38FZ 048 76 165 048 11.56 12.50 244 40BZ 048 38BZ 048 76 168

060 14.80 267 40BZ 060 38FZ 060 87 180 060 14.34 16.84 270 40BZ 060 38BZ 060 87 183

072 19.10 329 40BZ 072 38FZ 072 116 213 072 19.10 21.80 332 40BZ 072 38BZ 072 116 216

084 22.74 381 40TZ 084 38FZ 084 120 261 084 22.20 25.00 385 40BZ 084 38BZ 084 120 265

670

950

1320

1365

865

1350

1650

1875

50VZ/PZ - VERTICAL SPLIT UNITS

CONTROLS
Master Link II electronic control.

The 50VZ air-cooled split-system cooling units and 50PZ heat pumps are ideal for installation in new buildings or refurbishment proJects. FEATURES
Master Link II electronic control with LEDs for simple service and maintenance.

ACCESSORIES/OPTIONS
Head pressure control. Hot water coil. Crankcase heater (50VZ only). Outdoor air filter. Protection grille. Economizer. Minimum opening potentiometer. Return air sensor. Superior drive. 38VZ/PZ for vertical discharge.

Hermetic circuit made of deoxidised and dehydrated copper tubing.

Wide range of options such as crankcase heater, head-pressure control kit.

Unit cabinet is made of pre-painted sheet steel for thermal and acoustic unit insulation. Three-phase reciprocating or scroll compressors designed for R-407C refrigerant.

80

DUCTABLE 50VZ/PZ - AIR-COOLED VERTICAL SPLIT UNITS


DUCTABLE AIR-COOLED
Physical data
50VZ Nom. cooling capacity* Weight 50VZ 40PZ 38VZ 50PZ Nominal cooling capacity* Nominal heating capacity** Weight 50PZ 40PZ 38PZ Compressor (R-407C) Indoor/outdoor coil Indoor coil fan (40PZ) Nominal air flow Outdoor coil fan (38VZ) Nominal air flow
* **

DUCTABLE AIR-COOLED 50VZ/PZ

kW kg

015 14.60 230 78 152 015 13.42 15.76

025 22.74 390 140 250 025 21.81 25.02

030 29.75 402 150 252 030 28.50 30.58

031 27.80 410 150 260 031 27.70 30.20

040 35.05 618 230 388 040 34.36 39.15 638 230 408 scroll

045 45.21 842 297 545 045 43.60 50.18 864 297 567

055 53.90 894 317 577 055 52.1 57.43 919 317 602

065 63.89 943 335 608 065 61.94 66.60 968 335 633

075 74.35 1033 365 668 075 72.58 83.06 1058 365 693

kW kW kg

l/s l/s

238 400 412 427 78 140 150 150 160 260 262 277 Hermetic reciprocating Copper tubes, pre-treated aluminium fins Double inlet centrifugal type 960 1490 1690 1690 Double inlet centrifugal type 1470 3020 2780 2780

2190 3610

2640 4580

2910 5080

3140 6030

3530 6890

Based on an outdoor air temperature of 350C db and an indoor air temperature of 190C wb. Based on an outdoor air dry bulb temperature of 350C and a saturated suction temperature of 70C.

Electrical data
50VZ (40PZ/38VZ) Nominal voltage* Nominal power input** Nominal current drawn** Starting current 50PZ (40PZ/38PZ) Nominal voltage* Nom. power input, cooling** Nom. power input, heating*** Nom. current drawn, cooling** Nom. current drawn, heating*** Starting current V kW A A V kW kW A A A 015 230 7.3 23.8 139.5 015 230 7.2 6.6 23.7 22.5 139.5 400 7.3 13.8 80.0 400 7.2 6.6 13.7 13.0 80.0 025 230 11.1 33.1 174.1 025 230 11.2 11.1 33.2 33.2 174.1 030 230 14.0 39.4 219.0 030 400 230 11.2 13.6 11.1 12.4 19.2 38.4 19.2 35.8 106.3 219.0 400 11.1 19.1 106.3 031 230 14.6 44.9 165.9 031 400 230 13.6 14.6 12.4 12.7 22.2 46.0 20.7 41.5 133.3 165.9 400 14.0 22.8 133.3 400 14.6 26.0 95.3 400 14.6 12.7 26.6 24.0 95.3 040 230 18.1 52.6 235.2 040 230 18.1 17.5 55.0 52.2 235.2 045 230 21.4 64.9 278.4 045 400 230 18.1 21.6 17.5 20.8 31.8 66.1 30.2 63.7 134.0 278.4 400 18.1 30.4 134.0 055 230 25.4 74.3 329.1 055 400 230 21.6 25.4 20.8 23.7 38.2 73.3 36.8 70.7 156.7 329.1 400 21.4 37.5 156.7 065 230 30.0 87.8 384.5 065 400 230 25.4 30.2 23.7 27.1 42.4 88.0 40.9 82.0 187.8 384.5 400 25.4 43.0 187.8 075 230 37.6 122.1 450.1 075 400 230 30.2 38.5 27.1 34.3 50.9 118.5 47.4 109.8 219.0 450.1 400 30.0 50.8 219.0 400 37.6 67.1 256.0 400 38.5 34.3 68.6 63.5 256.0

* All units are built for 3-phase, 50 Hz supply. ** Based on an outdoor air dry bulb temperature of 350C and an indoor air wet bulb temperature of 190C. *** Based on an outdoor air temperature of 60C wb and an indoor air temperature of 210C db.

Dimensions, mm
50VZ/50PZ A B C 38VZ/38PZ A B C 40PZ A B C 015 910 850 1688 910 785 1180 015 910 850 588 025 1350 883 1890 1350 809 1280 025 1350 883 690 030, 031 1350 883 1940 1350 809 1280 030, 031 1350 883 740 040 1600 993 2095 1600 919 1435 040 1600 993 740 045, 055 2126 1154 2158 2126 1080 1498 045, 055 2126 1154 750 065, 075 2526 1154 2158 2526 1080 1498 065, 075 2526 115 750

68

81

50VZ/PZ

50JZ - VERTICAL SPLIT UNITS

heat pumps with optional electric heaters, low installation cost, dependable performance and easy maintenance.

FEATURES
Compact,fully self-contained heat pumps, pre-wired, pre-piped and precharged for minimum installation expense.

ACCESSORIES/OPTIONS
Cooper/cooper and vinyl-coated construction for refrigerant coils. Economizer with solid-state controls and baromrtric relief dampers. Manual air dampers 25% open. Electric heaters. Filter rack. Flat roof curbs. Square to round duct transition kit. Thermostat. Low ambient kit. Lifting kit. Crankcase heater.

Durable,dependable components-the high efficiency compressor is hermetically sealed against contamination for longer life and dependable operation and includes internal high pressure and over-current protection. The units are designed for easy use in either down flow or horizontal applications. Each unit is easily converted from horizontal to down flow. Direct drive multi-speed indoor fan motor is standard. Direct-drive outdoor fan motors help reduse energy consumption and provide cooling operation down to 12,80C outdoor temperature. Low sound ratings ensure a quiet indoor and outdoor environment.

82

DUCTABLE 50GL/50JZAIR-COOLED - VERTICAL SPLIT UNITS


DUCTABLE AIR-COOLED
Physical data
Nom. cooling capacity* cooling capacity* Nom. Nom. heating capacity** Nom. heating capacity** Operating weight Operating weight Commpressor Compressor Refrigerant Refrigerant Outdoor heat exchanger Outdoor heat exchanger Rows-fins Rows...fins Outdoor fan Outdoor Nominal air fan flow air flow Nominal Indoor heat exchanger Indoor heat exchanger Rows-fins Rows...fins Indoor fan Indoor air fan Nominal flow Return air filters air flow Nominal

DUCTABLE AIR-COOLED 50GL/50JZ

kW kW kW kW kg kg

50GL Cooling only 024 030 024 7,0 8.8 7.0 7,0 135,6 119.7 134.3 One scroll compressor R410A
2 ... 669 1038 3 ... 590 378

036 10.6 137.0

50JZ Heat pump 030 048 8,8 14.1 8,3 145,2 158.8 One scroll compressor R410A 2 ... 669 1038

50JZ Heat pump 036030 024 10,68.8 7.0 10,1 7.0 8.3 148,8 135.6 145.2

036 10.6 10.1 148.8

048 048 14,1 14.1 12,9 12.9 161

161.0

1 ... 669 l/s


I/s

1 ... 669 1109 3 ... 590 472

2 ... 669 1109 3.. 590 566

2 ... 669 1557 3 ... 590

2 ... 669 1038 3 ... 590 378

2 ... 669 1038

2 ... 669 1038 3 ... 590 472

2 ... 669 1038 4 ... 590 566

2 ... 669 1133

2 ... 669 1133 4 ... 590 708

1109 2 ... 590

3 ... 590

4 ... 590 566

4 ... 590 708

I/s

Return air filters

l/s

378

472 Throwaway 755

Throwaway

* **

Based on 270C db/190C wb indoor air entering temperature and 350C outdoor air entering temperature. Based on 210C db/8,30C wb indoor air entering temperature and 60C outdoor air entering temperature..

Electrical data
50JZ 50GL/50JZ Nominal power supply 10% 10% Nominal power supply Compressor Compressor Rated load current Rated load current Locked rotor current Locked rotor current Outdoor fan motor Outdoor fan motor Full load current Full load current Indoor fan motor

V-ph-Hz

V-ph-Hz

024 024 400-3-50 400-3-50

030 030 400-3-50 400-3-50

036 036 400-3-50 400-3-50

048 048 400-3-50 400-3-50

4.5 32 0.8 1.1

4,5 32 0,8 1,1

5.2 35 0.8 1.7

5,2 35 0,8 1,7

6.5 46 0.8 2.0

6,5 46 0,8 2,0

6.7 50 1.3 3.9

6,7 50 1,3 3,9

Indoor fan motor

Dimensions, mm
024 024 030 030 036 036 048

Clearances
C 831 831 831 1123
50JZ Heat 50JZpump Heat AB 890 1226 940 1226 940 1226 1041

048

50GL Cooling only A B A 1226 1226 940 1226 1226 991 1226 1226 890 1226 1226 990

1226

pump B 890 940 940 1041

Evaporator coil access side, power entry side,unit top ans side opposite ducts

CC 831 831 831 831 831 831 1123 1123

914mm, duct panel side (clearance to nearest wall) 305mm.

70

83

50AZ/50UZ - ROOFTOP UNITS

CONTROLS

The 50AZ/50UZ packaged rooftop units are versatile and efficient air conditioners, designed for outdoor installation. The units are self-contained and can be installed in commercial and industrial applications. FEATURES

PRO-DIALOG Plus.

Designed for operation with refrigerant HFC-407C.

ACCESSORIES/OPTIONS
Economizer. Electric heater. Hot water coil with 3-way proportional valve. Power exhaust. Superior drive (indoor fan). Dirty filter alarm. High-efficiency filters. Smoke detector with economizer. Crankcase heater (standard for 50UZ). Manual outdoor air damper. Air flow detector. Front discharge. Vertical roof curb. Adjustable longitudinal roof curb, vert, discharge. Air return fan. Additional space temperature sensor. Thermostat - programmable TSTAT. Stainless steel drain pan. Indoor air quality sensor

The unit cabinet is made of powder-painted sheet metal, especially suitable for outdoor use. Reduced size and weight make these units ideal for todays lightweight building structures.

The compressors are mounted on vibration isolators.

Pro-Dialog Plus control optimises the efficiency of the refrigerant circuit.

Shrouded axial Flying Bird fan made of composite plastic material for low-noise operation. The heat exchangers are made of high-quality staggered copper tubing, mechanically bonded in precoated corrugated aluminium fins.

84

DUCTABLE AIR-COOLED 50AZ/50UZ - ROOFTOP UNITS


DUCTABLE AIR-COOLED
Physical data
Nominal cooling capacity* Nominal heating capacity** Operating weight Compressor Quantity Indoor coil Outdoor coil Refrigerant charge kW kW kg 50AZ Cooling only unit 016 020 024 43.0 54.1 70.0 730 890 028 78.1 034 99.5 040 116.1 1470 R-407C 50UZ Heat pump 016 020 41.0 52.0 45.0 56.7 740 860 024 68.5 79.0 028 77.0 85.0 038 108 123 042 119.2 146.1 1650

1010 scroll 2

1027 scroll 2

1460 Herm. 2

1020 scroll 2

1037 scroll 2

1600 scroll 2

scroll 1

Herm. 2

Copper tubes, pre-treated aluminium fins Copper tubes, pre-treated aluminium fins One, centrifugal 5550 2528

Herm. 2

scroll 1

Herm. 2

scroll 2

Indoor fan and motor Air flow

Outdoor fan and motor Quantity


* **

l/s

2528 1

3444 2

3472 2

3944 2

5550

Axial Flying Bird fans with rotating shroud 2 2 1 2 2

3444

3472

3944 2

5500 2

5500 2

Based on an outdoor air dry bulb temperature of 35C and an indoor air wet bulb temperature of 19C. Based on an outdoor air wet bulb temperature of 6C and an indoor air dry bulb temperature of 21C.

Electrical data
Nom. power input, cooling* Nom. power input, heating** 50AZ Cooling only unit 016 020 024 kW 17.49 27.08 31.85 kW 36.30 182 49.33 133 028 37.11 034 45.70 040 54.10 50UZ Heat pump 016 020 17.01 26.12 16.77 21.91 35.09 34.54 182 46.76 42.00 133 024 31.76 33.54 56.23 58.02 184.3 028 35.41 36.37 63.45 64.22 216 038 51.15 48.26 38.49 92.87 271 042 63.35 58.28

Nom. current drawn, cooling* A Nom. current drawn, heating** A Starting current
* **

56.23 184.3

67.77 216

79.70 315

92.80 340

121.32 112.16 347

Based on an outdoor air dry bulb temperature of 35C and an indoor air wet bulb temperature of 19C. Based on an outdoor air wet bulb temperature of 6C and an indoor air dry bulb temperature of 21C.

Dimensions, mm
50AZ/UZ 016 50AZ/UZ 020

1138

1138

2189

2120

2189

2120

50AZ/UZ 024, 028

50AZ 034, 040/50UZ 038, 042

1544

1559

3577 2189 2120

2193

72

85

50AZ/50UZ

48AZ /UZ- PACKAGED ROOFTOP COOLING

FEATURES OPTIONS AND ACCESSORIES


Economizer (option). Crankcase heater (option). Front discharge roof curb (accessory). Vertical roof curb (accessory). Adjustable longitudinal roof curb, vertical discharge (accessory). Adjustable transverse roof curb, vertical discharge (accessory). Air return fan (accessory). Power exhaust (option). Dirty filter alarm (option). High-efficiency filters (option). Additional space temperature sensor (accessory). Smoke detector (option). Economizer hood (option/accessory). Programmable thermostat TSTAT (accessory). Non-programmable thermostat TSTAT (accessory). IAQ indoor air quality sensor (accessory). Manual outdoor air damper (option/ accessory). Air flow detector (option). Barometric exhaust (option). High and low static pressure transmission (option). Room-mate controller (accessory). Enhanced human interface (option). Propane gas option. Unit 48AZ - Six sizes with nominal cooling capacities from 43 to 116 kW and a nominal heat output from 47 to 147 kW. Unit 48UZ - Four sizes with nominal cooling capacities from 41 to 77 kW, nominal heating capacities from 45 to 85 kW and a nominal heat output from 47 to 73 kW. Versatile and efficient air conditioners, designed for outdoor installation. Self-contained and can be installed in commercial and industrial applications. Units use the new ozone-friendly refrigerant R-407C. Components are specifically designed for the new refrigerant. Reduced size and weight make these units ideal for todays lightweight building structures. Cabinet made of powder-painted sheet metal. The compressors are mounted on vibration isolators. Sizes 016, 024 and 028 have scroll compressors, the other sizes have reciprocating hermetic compressors. Crankcase heaters are standard for 48AZ 034 and 040. Double-inlet indoor fans have forward-curved blades. Revolutionary, low-noise, two-speed Flying Bird II fan, made of a composite recyclable material and uses a multi-blade design and rotating shroud. Heat exchangers made of high-quality staggered copper tubing, mechanically bonded in pre-coated corrugated aluminium fins. Refrigerant circuit uses deoxidised and dehydrated copper tubes with obus type access valves. It includes a full refrigerant charge, expansion valves and all components required for correct unit operation. Fully wired in accordance with EN standards. Simplified electrical connections. Gas heating system designed as an alternative to the hot water coil or electric heating options. Units are available with three gas heating modules. Tubular dimpled gas heat exchanger optimises heat transfer for maximum efficiency. Modular burner assembly consists of a series of injectors. Induced draft combustion system for improved efficiency. Integrated gas unit controller (IGC).

86

AND GAS HEATING UNITS

48 Nominal cooling capacity* Operating weight Refrigerant charge Compressor Quantity, circuit A/B Indoor/outdoor coil Indoor fan Air flow Outdoor fan Quantity air flow Heating modules Natural gas heating Net heat input (min./max.) Heat output (min./max.) Propane gas heating Net heat input (min./max.) Heat output (min./max.) Weight Power input (400 V, 3 ph, 50 Hz) Electrical data, cooling (400 V, 3 ph, 50 Hz) Nominal power input* Nominal current drawn* Starting current

kW kg

016 43 730 Scroll 1/-

020 54.1 850 Hermetic 1/1

024 70 1010 R-470C Scroll 1/1

028 78.1 1027 Scroll 1/1

034 99.5 1460 Hermetic 1/1

040 116.1 1470 Hermetic 1/1

Copper tubes, pre-coated aluminium fins One, centrifugal 1/s 1/s 2528 1...6600 5 cells 35.4/52.6 30.8/46.8 -/59.1 -/53.2 65 3444 3472 Axial Flying Bird fans with rotating shroud 2...10600 6 cells 48.6/69.4 41.8/61.8 -/71 -/63.9 73 0.22 27.08 49.33 133 2...10600 7 cells 56.7/81 49.9/72.9 -/82.8 -/74.5 80 0.22 31.85 56.23 184.3 3944 2...10600 5+5 cells 35.4/105.2 30.8/96.6 59.1/118.2 52.6/105.2 135 0.44 37.11 72.47 216 5550 2...13000 6+6 cells 48.6/138.8 42.8/125 71/142 63.9/127.8 150 0.44 45.70 79.70 315 5550 2...12500 7+7 cells 56.7/162 50.5/147.4 82.8/165.6 75.3/150.7 165 0.44 54.10 92.80 340

kW kW kW kW kg kW kW A A

17.49 36.30 182

*Nominal Eurovent conditions: outdoor air dry bulb temperature of 35oC, indoor air wet bulb temperature of 19oC.

48U Nominal cooling capacity* Nominal heating capacity** Operating weight Refrigerant charge Compressor Quantity, circuit A/B Indoor/outdoor coil Indoor fan Air flow Outdoor fan Quantity air flow Heating modules Natural gas heating Net heat input (min./max.) Heat output (min./max.) Propane gas heating Net heat input (min./max.) Heat output (min./max.) Weight Power input (400 V, 3 ph, 50 Hz) Electrical data, cooling (400 V, 3 ph, 50 Hz) Nominal power input (cooling*/heating**) Nominal current drawn (cooling*/heating**) Starting current

kW kW kg

1/s 1/s

016 020 41 52 45 56.7 740 860 R-470C R-470C Scroll Hermetic 1/1/1 Copper tubes, pre-coated aluminium fins One, centrifugal 2528 3444 Axial Flying Bird fans with rotating shroud 1...6100 2...6600 5 cells 6 cells 35.4/52.6 30.8/46.8 n.a./59.1 n.a./53.2 65 0.22 17.01/16.77 35.09/34.54 182 48.6/69.4 41.8/61.8 n.a./71 n.a./63.9 73 0.22 26.12/21.91 46.76/42 133

024 68.5 79 1020 R-470C Scroll 1/1

028 77 85 1037 R-470C Scroll 1/1

3472 2...10600 7 cells 56.7/81 49.9/72.9 n.a./82.8 n.a./74.5 80 0.22 31.76/33.54 56.23/58.02 184.3

3944 2...10600

kW kW kW kW kg kW kW A A

35.41/36.37 63.45/64.22 216

*Nominal Eurovent conditions: outdoor air dry bulb temperature of 35oC, indoor air wet bulb temperature of 19oC. **Nominal Eurovent conditions: outdoor air wet bulb temperature of 6oC, indoor air dry bulb temperature of 20oC.

87

48/UZ

42N - FAN COILS

CONTROLS

The 42N product range combines aesthetic and attractive design with versatility to satisfy any application need, from large office buildings or hotels to shops and residential applications. FEATURES
Cabinet models for floor, wall or under-ceiling installation and models without cabinet for furred-in installation.

ACCESSORIES/OPTIONS
Economizer. Electric heater. Hot water coil with 3-way proportional valve. Power exhaust. Superior drive (indoor fan). Dirty filter alarm. High-efficiency filters. Smoke detector with economizer. Crankcase heater (standard for 50UZ). Manual outdoor air damper. Air flow detector. Front discharge. Vertical roof curb. Adjustable longitudinal roof curb, vert, discharge. Air return fan. Additional space temperature sensor. Thermostat - programmable TSTAT.

Flexible drain pan allows the same unit to be installed in a vertical or horizontal position. Integrated factory-mounted cooling and heating coil for four-pipe applications.

User-friendly stylish one-touch control with improved features.

Designed for ultra-quiet operation with sound levels that set new standards in the industry.

Installation is easier than ever.

Installation is easier than ever.

88

CHILLED WATER TERMINALS 42N - FAN COILS


CHILLED WATER TERMINALS
Physical data
42N Unit with tangential fan Air flow (l/m/h) Total cooling capacity Sensible cooling capacity Water flow rate (cooling) Water pressure drop (cooling) Heating capacity Electric heater (low/high) Unit with centrifugal fan Air flow (l/m/h) Total cooling capacity Sensible cooling capacity Water flow rate (cooling) Water pressure drop (cooling) Heating capacity Electric heater (low/high) 16 l/s kW kW l/s kPa kW kW l/s kW kW l/s kPa kW kW 43/69/90 1.43 1.11 0.068 17.8 1.88 0.5/1 60/74/92 1.44 1.12 0.069 16.6 1.88 0.5/1 25 72/99/131 2.18 1.82 0.104 11.8 2.84 1/2 81/100/167 2.43 2.04 0.116 13.6 3.43 1/2 33 69/128/158 3.14 2.52 0.15 10.3 3.93 1/2 93/144/190 3.53 2.82 0.169 12.5 4.65 1/2 43 111/179/227 4.04 3.28 0.19 17.6 5.38 1.5/3 125/194/238 4.17 3.31 0.199 20 5.58 1.5/3 50 128/176/242 4.42 3.55 0.211 19.9 5.85 1.5/3 150/231/282 4.967 3.93 0.223 23 5.88 1.5/3 60 175/272/339 5.57 4.36 0.266 19.4 7.30 1.5/3 75 228/328/438 6.55 5.23 0.313 18.3 9.11 1.5/3

42N

Based on Eurovent conditions: Cooling mode (2-pipe coil): entering air temperature 270C db/190C wb, entering/leaving water temperature 7/120C, high fan speed. Heating mode (2-pipe coil): entering air temperature 200C, entering water temperature 500C, high fan speed, water flow rate as cooling mode.

Electrical data

Tangential fan

A V-ph-Hz W

0.15 0.14

0.35 0.15

0.38 0.19

0.33 0.25 230-1-50 75 63

0.43 0.31

0.51 -

0.72 -

Power Supply Power Input Centrifugal fan Tangential fan

32 32

78 32

85 44

98 69

113 -

164 -

Three-speed electric motors with permanent capacitor, class B.

Dimensions, Weight
42N A (units with cabinet) Weight (units with cabinet) A (concealed units) Weight (concealed units) mm kg mm kg 16 830 17 599 13 25 1030 19 799 15 33 1030 19 799 15 43 1230 22 999 16 50 1230 22 999 16 60 1430 35 1199 28 75 1430 35 1199 28

74

220

657 (units with cabinet) 618 (concealed units)

89

42N

42N Power Supply Current drawn Centrifugal fan

16 V-ph-Hz

25

33

43 230-1-50

50

60

75

42CE - CONCEALED ROOM

FEATURES
Five sizes with two-pipe or 4-pipe coils, with an air flow range from 60 to 280 l/s, a cooling capacity range from 1.5 to 5.6 kW and a heating capacity range from 2.3 to 7.2 kW. Compact, concealed chilled-water fan coil units, designed for installation above false ceilings. Reliable and economical cooling and heating for hotels, light commercial and residential applications. Optimised design for market competitiveness. No filter as standard for increased installation flexibility. Extended blue drain pan for control valve installation. Front air outlet, using a sleeve. Low sound level. Three-speed fan motor. High-pressure centrifugal fans, compatible with all main air distribution systems. Two-pipe two or three-row coil for increased selection flexibility. High-efficiency four-pipe coil. Low hydraulic pressure drop with a valve mounted, compatible with all chiller pump kits.

STANDARD CONTROLS
Electronic thermostat. Two versions, A and B, with potentiometer. Automatic or manual three-speed selection. Automatic or manual change-over. Electric heat control. Comfort/economy/frost protection modes. HDB controller Digital display or infra-red terminal. Unit grouping capability Adjustable settings and parameters. Timer and daily scheduling. NTC communicating controller Network communication. Aquasmart Evolution system compatible. IAQ and DCV management. Motorised blinds and lighting control.

OPTIONS/ACCESSORIES
Return air box with filter.

90

FAN COIL UNIT

42CE Air flow 1/s m3/h Pressure drop Total cooling capacity* Sensible cooling capacity * Water flow rate Pa kW kW 1/s 1/h Water pressure drop Heating capacity* Water flow rate kPa kW 1/s 1/h Water pressure drop Sound power level Sound pressure level* NR value** Power supply Power input Current draw Coil outlet/inlet diameters Length Height Depth C Weight V-ph-Hz W A inch mm mm mm kg kPa dBA dBA

002315 61-78-94 220-280-340 50-35-20 1.54-1.87-2.20 1.04-1.31-1.58 0.08-0.09-0.11 277-336-396 9-11-14 2.33-2.72-3.24 0.07-0.08-0.10 255-302-360 7-8-10 48-52-55 36-40-43 31-35-39 230-1-50 58 0.25 3/4 690 220 466 14

003315 92-117-142 330-420-510 50-35-20 2.17-2.63-3.06 1.49-1.87-2.23 0.11-0.13-0.15 383-464-540 17-20-25 3.13-3.65-4.29 0.10-0.11-0.13 350-408-480 21-24-29 47-52-56 35-40-44 29-34-39 230-1-50 65 0.28 3/4 770 220 466 15.6

004315 122-156-189 440-560-680 50-35-20 3.47-3.35-4.08 2.16-2.63-3.09 0.14-0.18-0.21 516-642-738 14-17-20 3.78-4.39-5.11 0.10-0.11-0.13 355-412-480 30-35-41 47-52-56 35-40-44 29-34-39 230-1-50 89 0.39 3/4 890 220 466 17.7

005315 150-192-236 540-690-850 50-35-20 3.31-3.94-4.53 2.53-3.08-3.62 0.17-0.20-0.23 600-720-828 17-20-24 4.68-5.44-6.32 0.10-0.11-0.13 355-412-480 30-35-41 49-54-58 37-42-46 32-37-41 230-1-50 108 0.47 3/4 970 220 466 19.1

006315 183-231-283 660-830-1020 50-35-20 4.25-5.04-5.66 2.98-3.70-4.25 0.20-0.25-0.28 715-905-1020 24-30-35 5.36-6.22-7.15 0.15-0.17-0.20 540-626-720 26-30-35 51-56-61 39-44-49 32-38-43 230-1-50 126 0.55 3/4 1090 220 466 20.5

* Based on standard Eurovent conditions: Cooling 27C db/19C wb air temperature, 7C/12C entering/leaving water temperature. 4-pipe heating: 20C air temperature, 70C/60C entering/leaving water temperature. **NR sound levels are based on a hypothetical acoustic attenuation for the room and the system (diffuser, ductwork, ceiling) of -12 dB(A).

91

42CE

42GW - CASSETTES

The Carrier 42GW hydronic cassette offers a modern solution for a wide variety of small and medium-sized commercial and residential applications. FEATURES
All key components - filters, pump and electronic board - are easily accessible by opening the grille. For optimal comfort the unit is designed for almost horizontal air throw in cooling mode and 300 downward directed throw in heating mode.

ACCESSORIES/OPTIONS
Remote fan speed switch with thermostat. Photo-catalytic and passive electrostatic filter. Auxiliary condensate discharge pump and drain pan kit. Air supply outlet obstruction kit. Auxiliary board (grouping connection). Drain pan kit. Motorised valve kit and drain pan. Primary air kit. Cassette grille with parallel louvres.

The centrifugal fan with wing-shaped blades ensures acoustic comfort.

The fresh-air intake guarantees continuous room air renewal.

Washable filters are supplied as standard. Electrostatic and activated carbon filters are also available as optional extras. Unit is light and easy to install. The small chassis size is compatible with standard ceiling tiles and simple to install wherever it is needed.

92

CHILLED WATER TERMINALS 42GW - CASSETTES


CHILLED WATER TERMINALS
Physical data

42GW Model

Unit size

42GW CHILLED WATER TERMINALS 42GW

cooling capacity Total Fan speed (LxMxH) cooling capacity AirSensible flow
Cooling mode 2-pipedrop systems Water pressure Total cooling capacity* (cooling) Sensible cooling capacity* Heating capacity Water flow heaters Electric

Water flow rate (cooling)

kW kW 1/s l/s m3/h


kW kPa kW kW 1/s

004 42GWC 008 42GWC 42GWC 010 42GWD004 42GWD008 004 42GWE 008 42GWE 42GWE 010 42GWE004 42GWE008 2.4 4.0 4.7 2 100-125-1843.1 3.9 89-136-194 0.11 0.22 360-450-6620.19 310-490-698 9 1.55-1.90-2.412 1.31-1.49-2.01 3.2 4.2

42GWC004

42GWC008

012 42GWC 42GWD010 012 42GWE 42GWE010 6.3 5.2 131-167-236 0.28 472-601-850

42GWC010

42GWC 016 42GWC 020 42GWE 016 42GWE 020 7.6 10 5.1 7.1 150-203-283 0.40 540-731-1019 0.53

42GWC012

42GWD 004 42GWD 008 42GWD 010 42GWD 020 1.9 3.2 4.0 9.8

42GWE012

42GWC016

42GWE016

1.7 2.9 147-242-338 3.4 150-203-283 0.09 0.16 529-871-1217 0.19 540-731-1019

7.3 147-242-338 0.43 529-871-1217

1/h (42GWE models) kW Water drop flow (low-medium-high) Air pressure l/skPa Heating mode 2-pipe syst. (42GWC) O Power Input 70 2.4 85 4.0 95 4.7 85 6.3 1207.6 20010 70 1.9 85 3.2 95 4.0 2009.8 WkW Heating capacity* kW 2.16-2.49-3.15 2.02-3.43-4.19 3.69-4.38-6.02 4.38-5.87-8.11 4.80-6.30-8.50 4.30-7.30-10.80 4.58-7.14-9.70 Weight, unit 19 2 20 3.1 20 3.9 41 5.2 43 5.1 46 7.1 19 1.7 20 2.9 20 3.4 46 7.3 kgkW Water pressure kPa 3.7-5.0-10.0 3.8-6.9-12.5 5.0-8.0-17.0 6.5-10.0-19.0 6.5-8.0-16.0 2.7-5.6-12.3 3.4-7.9-13.6 Weight, grille () 2.50.11 2.50.19 2.50.22 5.00.28 5.00.40 5.00.53 2.50.09 2.50.16 2.50.19 5.00.43 kgl/s W 1500 2500 2500 3000 3000 Electric heaters (42GWE only) Power Supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Heating mode 4-pipe systems 970C/120C entering 12 and leaving20 19 at high fan15.3 25 10.8 12.0 19.7 30.0 kPa () Coolingcapacity* conditions: 270C db/190C wb air temperature, water temperature speed. Heating kW 1.20-1.40-1.90 2.13-3.18-4.25 2.73-3.50-4.61 0 Heating conditions (2 pipes): 200C air kW temperature, 50 C entering water flow speed. 3.2 4.2 temperature, 6same water 8.1 rate as in cooling, 10.8 at high fan 13.9 1.9 4.2 4.6 9.0 0 0 0 Water flow rate 1/s 0.03-0.03-0.04 0.05-0.08-0.10 0.07-0.08-0.11 Heating conditions (4 pipes): 20 C air temperature, 70 C/60 C entering and leaving water temperature at high fan speed. 1/h 107-124-163 183-273-366 235-301-396 1.5 2.5 20.0-24.4-24.4 2.5 3.0 3.0 3.0 kW (42GWE ) Water pressure drop kPa 14.2-19.2-30.7 41.5-62.2-66.3 100/125/184 l/s V-ph-Hz 230-1-50 86/136/194 131/167/236 150/203/283 147/242/338 178/315/468 100/125/184 86/136/194 131/167/236 178/315/468 Power supply 50 (X/M/Y) 70 85 95 85 120 33-51-85200 70 85 40-75-120 95 200 W Power input W 40-50-70 80-60-90 60-80-100 33-51-85 40-75-120 42GW A B C19 20 F 41 43 36-41-49 46 19 20 41-49-56 20 46 kg , Sound power level dB(A) 34-38-49 D 20 E 34-45-54 44-50-59 36-41-49 41-49-56 004 pressure 575 298 575 Sound dB(A) 22-26-37 720 2.5 30 22-33-42 32-38-47 24-29-37 29-37-44 2.5 2.5 720 5.0 5.0 24-29-37 5.0 2.5 2.5 29-37-44 2.5 5.0 kg , level** 008 575 V-ph-Hz 298 575 720 230-1-50 NR value 17-21-32 720 17-28-37 27-33-42 230-1-5019-24-32 19-24-32 24-32-39 24-32-39 230-1-50 230-1-50 30 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Dimensions unit (HxLxD) 575 Mm 298x575x575 298x575x575 298x825x825 298x825x825 298x825x825 298x825x825 010 298 575 720 30 720 298x575x575 : 27C/ 19C , 7C/12C / . A30x960x960 Dimensions grille (HxLxD) Mm 30x720x720 30x720x720 30x720x720 30x960x960 30x960x960 012 825 20C 298 825 30 , 960 (2): , 50C 960 30x960x960 , . C (4): ,19 70C/60 Weight kg 20 41 .41 43 43 016 unit 825 20 C 298 825 960C 30 20 / 960 Weight kg 2.5 5 5 5 5 020 grille 825 298 825 2.5 960 30 2.5 960

1.90-2.85-4.00 2.85-3.50-4.70 15.3 3.40-4.50-6.30 3.40-4.50-5.90 4.10-6.10-8.30 20 19 25 10.8 12.0 3.17-5.10-7.60 19.7 30.0 1.41-2.16-3.10 2.30-2.80-3.90 10.8 2.70-3.60-5.20 2.70-3.60-4.80 2.67-4.24-5.81 6 8.1 13.9 1.9 4.2 1.74-3.24-5.11 4.6 9.0 0.07-0.09-0.11 0.09-0.14-0.19 0.14-0.17-0.22 0.16-0.22-0.30 0.16-0.22-0.28 0.15-0.24-0.36 0.20-0.29-0.40 267-327-4132.5 327-490-688 490-602-808 3.0 585-774-1084 545-877-1307 42GWC004 42GWC008 42GWC010 3.0 42GWC012 42GWC016 42GWC020 585-774-1015 42GWD004 42GWD008 42GWD010 705-1049-1428 42GWD020 1.5 2.5 3.0 3.7-5.0-10.0 86/136/194 4.0-7.0-12.0 6.0-10.0-20.0 147/242/338 9.0-12.3-24.6 2.8-5.6-14.0 4.4-9.8-15.3 42GWE004 42GWE008 42GWE010 150/203/283 42GWE012 42GWE016 42GWE020 8.0-11.0-19.0 100/125/184 131/167/236 178/315/468 100/125/184 86/136/194 131/167/236 178/315/468

Dimensions, mm

, mm
Unit size

B Fan speed (LxMxH) 004 575 298 Water circuit Air flow 008 1/s 575 298 Maximum water-side pressure m3/h 010 575 298 Minimum entering water 825 temperature Cooling mode 2-pipe systems 012 298 Total cooling entering capacity* water temperature kW Maximum 016 825 298 Sensible capacity* kW Room cooling air 020 825 298 Water flow 1/s Minimum temperature

Operating limits 42GW A

C D 575 720 178-315-468 575 720 641-1134-1685 575 720 825 960 3.90-7.10-10.0 825 960 2.52-4.78-7.15 825 960
0.19-0.34-0.48 671-1221-1720 4.4-12.4-24.0

42GWC020

Water pressure drop Power Supply Heating mode 2-pipe syst. (42GWC) Nominal single-phase voltage kW 230 V, 50 Hz Heating capacity* 5.40-10.0-13.90 5.80-10-30-14.40 Water pressure 3.3-10.7-21.3 4.9-14.7-27.0 Operating voltage limits kPa 1981400 V-264 V kPa W to 00C, it is advisable to empty the 3000 Electric heaters (42GWE only) can go down 0circuit to If the room temperature * water +4 C avoid damage by ice. Heating mode 4-pipecaused systems 0 +80 C Heating capacity* kW 5.10-7.90-9.00 Water flow rate 1/s 0.12-0.19-0.22 0 1/h 439-679-774 5 C* 0 Water pressure drop kPa 22.0-43.0-58.0 32 C V-ph-Hz Power supply 50 Power input W 70-140-200 70-140-200 230 V, 50 Hz Sound power level dB(A) 42-55-63 42-55-63 198 V-264 V Sound pressure level** dB(A) 30-43-51 30-43-51 *NR value 0C, 25-38-46 28-38-46 . Dimensions unit (HxLxD) Mm 298x825x825 298x825x825 Dimensions grille (HxLxD) Mm 30x960x960 30x960x960 Weight unit kg 46 46 Weight grille kg 5 5

Maximum temperature

1/h kPa

30 178-315-468 30 1400 kPa 641-1134-1685 30 +4C 30 4.60-8.10-11.0 +80C 30 3.22-5.78-8.15 30 0.22-0.39-0.53 5C*

42GWD020 42GWE020 E

F 720 720 720 960 960 960

B A C

791-1393-1892 32C 5.0-15.0-25.0

* Based on standard Eurovent conditions: Cooling 27C db/19C wb air temperature, 7C/12C entering/leaving water temperature. 2-pipe heating: 20C air temperature, 50C entering water temperature, same water flow rate as in cooling. 4-pipe heating: 20C air temperature, 70C/60C entering/leaving water temperature. **Sound pressure levels are based on a hypothetical acoustic attenuation for the room and the system (diffuser, ductwork, ceiling) of -18 dB(A) for a 2-pipe system.

76

93

42GW

42DW - HORIZONTAL SATELLITE FAN COIL

FEATURES STANDARD CONTROLS


Electronic thermostat Two versions, A and B, with potentiometer. Automatic or manual three-speed selection. Automatic or manual change-over. Electric heat control. Comfort/economy/frost protection modes. HDB controller Digital display or infra-red terminal. Unit grouping capability. Adjustable settings and parameters. Timer and daily scheduling. NTC communicating controller Network communication. Aquasmart Evolution system compatible. IAQ and DCV management. Motorised blinds and lighting control. Available in four sizes with two-pipe, two-pipe plus electric heater or four-pipe coils, with an air flow range from 230 to 800 l/s, a cooling capacity range from 5 to 13 kW and a heating capacity range from 7 to 20 kW. Compact ducted chilled-water fan coil units, designed for installation above false ceilings. Reliable and efficient heating and cooling for light commercial and residential applications. Minimised size, using a V-shaped coil. Reduced height of 285 mm. Air return from the rear or below for increased installation flexibility. Air outlet modularity (sleeve or spigots), outlets on the front or at the sides. High-capacity unit with low sound levels. Four-speed motor, offering a choice of two medium comfort speeds. High-pressure centrifugal fans, compatible with all main air distribution systems. Compatible with the 35BD/SR air diffuser range. Two-pipe coil with three rows (42DWC 07 and 12) or 4 rows (42DWC 09 and 16) for increased selection flexibility. Safe factory-installed electric heater for single or two-stage hot water heating. High-efficiency four-pipe coil. Low hydraulic pressure drop with a valve mounted, compatible with all chiller pump kits. Quick installation with factory-installed options (controls, valves). Improved market competitiveness.

OPTIONS/ACCESSORIES
Factory-installed two- or four-way valves. High-efficiency filter.

94

UNITS

Unit size Fan speed Fan Air flow 1/s m3/h Static pressure Cooling mode Total cooling capacity* Sensible cooling capacity* Water flow rate kW kW 1/s 1/h Water pressure drop 2-pipe heating mode Heating capacity* 4-pipe heating mode Heating capacity* Water flow rate Water pressure drop Electric heater capacity Sound levels Sound power level Sound pressure level** NR value*** Electrical data Power supply Power input Current draw Dimensions Coil outlet/inlet diameter Length A Height B Depth C Weight inch mm mm mm kg V-ph-Hz W A dBA dBA kW 1/h kPa W kW kPa Pa

42DWC07 L-M-H

42DWC09 L-M-H

42DWC12 L-M-H

42DWC16 L-M-H

42DWD09 L-M-H

42DWD16 L-M-H

228-250-260 820-900-935 40-50-55

253-303-349 910-1090-1256 35-50-65

478-562-632 1719-2024-2276 35-50-60

601-655-692 2162-2359-2491 40-50-55

301-368-433 1083-1323-1560 0-0-0

658-738-805 2369-2655-2899 0-0-0

5.08-5.5-5.67 4-4.33-4.47 0.24-0.26-0.27 870-940-980 16-21.1-23.2

5.88-6.81-7.69 4.54-5.32-605 0.28-0.33-0.38 1020-1170-1355 16.1-21.5-27.5

9.29-10.36-11.15 7.53-8.52-9.28 0.45-0.51-0.54 1630-1825-1950 38-45-55

12.44-13.39-13.65 10-10.59-10.72 0.59-0.64-0.67 2135-2305-2425 48.3-56.1-58.4

6.34-7.33-8.19 4.92-5.79-6.55 0.31-0.35-0.40 1110-1275-1425 26-32-39

11.32-12.12-12.64 9.38-10.16-10.69 0.56-0.60-0.63 2010-2150-2250 48-54-58

6.74-7.28-7.6

7.95-9.31-10.5

13.09-14.8-16.26

17.35-18.71-19.76 8.24-9.3-10.15 0.19-0.22-0.24 700-775-850 15-17-21 15.35-16.41-17.28 0.35-0.38-0.40 1265-1370-1440 45-51-56 3000

3000

3000

3000

3000

3000

51-53-54 33-35-36 28-30-31

52-56-60 34-38-42 29-33-37

57-61-63 39-43-45 34-38-40

63-65-67 45-47-49 40-42-44

53-58-63 35-40-45 30-35-40

69-71-73 51-58-55 46-48-50

230-1-50 85-95-105 0.37-0.41-0.45

230-1-50 125-165-195 0.55-0.71-0.85

230-1-50 265-310-360 1.16-1.37-1.57

230-1-50 370-410-450 1.63-1.76-1.94

230-1-50 135-175-220 0.58-0.76-0.95

230-1-50 400-460-510 1.82-2.04-2.24

3/4 925 285 750 35

3/4 925 285 750 37

3/4 1325 285 750 48

3/4 1325 285 750 53

3/4 925 285 750 37

3/4 1325 285 750 53

*Based on standard Eurovent conditions: Cooling 27C db/19C wb air temperature, 7C/12C entering/leaving water temperature. 2-pipe heating: 20C air temperature, 50C entering water temperature, same water flow rate as in cooling. 4-pipe heating: 20C air temperature, 70C/60C entering/leaving water temperature. **Sound pressure level measured in a 100 m3 room with a reverberation time of 0.5 seconds (-8 dB) ***NR sound levels are based on a hypothetical acoustic attenuation for the room and the system (diffuser, ductwork, ceiling) of -12 dB(A).

95

42DW

42WTN - HYDRONIC HIGH-WALL

FEATURES
Four sizes as a two-pipe with nominal cooling capacities from 2.3 to 7.0 kW and nominal heating capacities from 4.1 to 11.5kW.

STANDARD CONTROLS
Electronic wired thermostat Two versions, A and B, with potentiometer. Automatic or manual three-speed selection. Automatic or manual change-over. Electric heat control. Comfort/economy/frost protection modes. Wireless remote controller Digital display or infra-red terminal. Wireless remote control with a microcomputer comfort controller. Adjustable settings and parameters.

Aesthetically designed high-wall chilled-water fan coil system.

Reliable and economical cooling and heating for hotels, light commercial and residential applications.

Unit mounted two or three way valve as an option.

Tangential fan for low sound levels.

Safe factory-mounted electric heater for single or dual-stage hot water heating.

OPTIONS/ACCESSORIES
Fully featured back panel. Factory-mounted two or three-way valve. Electrical Heaters. Low hydraulic pressure drop with a valve mounted, compatible with all chiller pump kits.

96

FAN COIL UNITS

Size Cooling mode Total cooling capacity* Sensible cooling capacity* Air flow rate (L//H) Water flow rate Water pressure drop Dehumidification Heating mode Heating capacity* Electric heaters Power supply Power Input Sound Pressure** (//) Dimensions Length A Height B Width C Weight mm mm mm kg kW kW Volt/Hz/ph Watt dB(A) kW kW m3/h I/min kPa 1/h

42WTN-15

42WTN-30

42WTN-35

42WTN-50

2,3 1,8 320/400/500 6,5 7 0,6

4,5 4,05 680/850/1000 13 8 1,2

5,8 4,8 830/1050/1250 17 10 1,6

7,0 5,3 980/1250/1500 20 13 2,2

4,1

6,6

9,38

11,5

220/240V,50Hz, 1ph 50 42/44/46 70 45/50/54 70 43/51/54 100 49/53/56

820 320 170 15

1150 350 200 18

1150 350 200 30

1800 350 200 38

*Based on standard Eurovent conditions: Cooling: 27C db/19C wb air temperature, 7C/12C entering/leaving water temperature at high fan speed. Heating: 20C air temperature, 50C entering water temperature, same water flow rate as in cooling, at high fan speed. **Sound pressure is measured in a 100 m3 room with 0.5 seconds reverberation time.

97

42WTN

42VP - HORIZONTAL FAN COILS

The 42VP units from Carrier offer reliable, economical cooling and heating for medium-size commercial installations, shops and offices. One of these high-capacity units can be used instead af several separate fan coils. FEATURES
The cabinet is made of pre-painted galvanised sheet steel.

ACCESSORIES/OPTIONS
Electric resistance heaters (option/ accessory). Hot water coils for four-pipe installations (option/accessory). Room thermostat. Wired 220 V control - various versions (accessory). Superior drives for higher static pressure (option).

All sizes include thermal and acoustical insulation and a condensate pan with external insulation and a drain connection. The special ripple construction and tube arrangement ensures optimum heat transfer. The centrifugal fans with forward-curved blades are statically and dynamically balanced, with adjustable belt drives and three-phase motors.

All sizes include totally enclosed motors with self-lubrificating bearings.

Cleanable filters protect coil and motor against dust and air-borne pollutants.

98

CHILLED WATER TERMINALS 42VP - HORIZONTAL FAN COILS

Physical data
42VP Nominal cooling capacity* Nominal heating capacity** Weight Water-air heat exchanger Water inlet/outlet connection diameter Test pressure Fan Air flow rate Air filters Quantity
* **

CHILLED WATER TERMINALS 42VP

kW kW kg inch bar l/s

025 030 28 33 67 77 140 150 Copper tubes, aluminium fins 1-1/4 1-1/4 30 30 Two, centrifugal double inlet 1490 1690 Filter class M1 2 2

040 41 96 230 1-1/2 30 2190 2

045 59 129 297 2 30 2640 3

055 66 148 317 2 30 2910 3

075 78 172 365 2 30 3530 3

Based on an indoor air temperature of 270C db/190C wb, a water entering temperature of 70C, a water temperature difference of 5 K and nominal air flow. Based on an indoor air temperature of 200C db, a water entering temperature of 700C a water temperature difference of 10 K and nominal air flow.

Electrical data
42VP Supply voltage +10%* Nominal power input** Nominal current drawn** Starting current
* **

V kW A A

025 230 1.21 3.98 19.7

400 1.21 2.30 11.4

030 230 1.38 4.84 29.8

400 1.38 2.80 17.2

040 230 2.45 8.30 60.9

400 2.45 4.80 35.2

045 230 2.85 9.34 60.9

400 2.85 5.40 35.2

055 230 3.85 11.94 93.2

400 3.85 6.90 53.9

075 230 5.40 15.92 124.2

400 5.40 9.20 71.8

All units have three-phase 50 Hz power supply. For nominal air flow.

42VP A B C

025 1350 690 883

030 1350 740 883

040 1600 755 993

045 2126 755 1154

055 2126 755 1154

075 2526 750 1154

A C B

* Leave sufficient free space on both sides for air filter and belt drive replacement.

82

99

42VP

Clearances, mm

42GM - DUCTED FAN COIL UNITS

FEaTUREs
One size with a nominal air flows of 125 l/s. Designed to heat or cool individual zones in multi-zone commercial, industrial or institutional buildings. Designed for centralised installation (side by side) above false ceilings (in corridors, plant rooms or under staircases). High pressure systems available (200 Pa), permitting installation outside the conditioned space.

accEssoRIEs
Power Module for light, socket and blind operation. Suspension rail kit. Front fastening support kit. Rectangular duct separation kit. Zone user interface. Wall mounting support. Electrical connectors. Fresh air duct.

Low noise and vibration transmission from the unit to the conditioned space. Each zone has its own independent ducting system, reducing the risk of cross contamination. Can be shut down for servicing without affecting any other parts of the system. High-efficiency F6 filter. Can be equipped with a UV-PCO air purifier for optimal Indoor Air Quality (IAQ). Fresh air inlet with adjustable air quantity admits 8.3 to 16.6 l/s of ventilation air. Variable-speed centrifugal fan. Can be equipped with a Carrier Maestro numeric controller providing each room with its own desk- or wall-mounted user interface. A Building Management System (BMS) allows each unit to be monitored and controlled centrally.

100

DUCTED FAN COIL UNITS


DUCTED FAN COIL UNITS
Physical and electrical data
42GM 2 pipes + electric heater l/s kW kW kg V-ph-Hz kW Pa 198 2.8 30 230-1-50 (10%) CE approved 1.75 4 pipes 198 2.44 2.27 30 230-1-50 (10%) Nominal air flow Nominal cooling capacity* Total capacity Nominal heating capacity** Operating weight (6-row coil) Power supply PTC electric heater*** Maximum capacity at nom. air flow Fan Available static pressure at nom. air flow Fan motor Running current Max. power input at 230 V Fresh air connection Outside diameter Min./max. constant initial air flow (-10%, + 20%) A W mm l/s

42GM

DUCTED FAN COIL UNITS 42GM

Centrifugal, forward curved single wheel, double inlet 320 320 2-pole open, asynchronous, protection class IP44, permanent capacitor, class B insulation, paint class F, connected to a speed controller 0.81 0.81 174 174 125 8.3/44.4 125 8.3/44.4

Based on 7C water entering temperature, 27C db room air temperature, 47% relative humidity, 5 K t at nominal air flow. * ** Based on 50C water entering temperature, 19C room temperature, 10 K t at nominal air flow. *** PTC - Positive temperature coefficient

Dimensions, mm

42GM with front fastening support with constant-flow fresh air

84
101

42GM

42EM ATMOSPHERA

FEATURES
Nine sizes, each supplied in three models (three motor drives) with nominal air flows from 75 - 550 l/s and capacity from 1,7-15 kW. Units includes centrifugal fan, fresh air inlet with an air flow regulator (option), chilled water cooling coil and either hot water heating coil or electric heater. Complete system comprises one or more Carrier air or water-cooled chillers and one or more air handling units to supply fresh air to the 42EM Atmosphera units.

ACCESSORIES
Carrier electronic thermostat. Maestro Zone User Interface. Wall-mounted base for Zone User Interface. Maestro wall-mounted ambient temperature sensor. Maestro wall mounted three-speed thermostat. Condensate drain pump.

Installed in false ceilings. With its low height the 42EM Atmosphera can be installed in most areas. Its design allows for easy maintenance. The Atmosphera has been designed to be particularly quiet. Can be equipped with a Carrier numeric controller, providing optimised comfort for all building occupants. Equipped with an EU3 (85% gravimetric efficiency) filter. Other filter types are available on request. Two Atmosphera versions are available: - The base unit is designed with open (non-ducted) return air inlet with filter removal from the rear of the unit. - A version with ducted return air is available by adding the returnplenum sub-assembly. In this case filter removal is from below the unit. Can be equipped with an air purifier for optimal Indoor Air Quality (IAQ).

102

DUCTED FAN COIL UNITS

42EM ATMOSPHERA
42EM 10 20 21 22 23 30 Air flow 1/s(m3/h) 132(475) 154 (555) 162 (584) 219 (790) 307( 1104) 154 (555) Pressure drop Pa 62 61 60 65 51 61 Cooling mode Total cooling capacity* 3.1 data 3.87 4.04 5.19 6.43 4.63 Physical andkW electrical Sensible cooling capacity* kW 2.37 2.88 3.01 3.95 4.99 3.22 42EM 2.0 0.25 (893)2.1 0.31 (1106) 2.2 Water flow rate 1/s(1/h) 0.15 (533) 0.19 (666) 0.19 (695) 0.22 (796) Nominal air flow 253 28 Water pressure drop kPa 42 35l/s 36 132 48 183 75 kW 3.3 4.8 5.4 Total cooling 2-pipe heating mode capacity - cold water coil* Heating capacity - hot water coil** kW 1.7 2.6 3.0 Power supply V-ph-Hz 230 V-1 ph-50 Hz ( 15%) Heating capacity* kW 3.86 4.3 4.92 6.43 8.09 5.29 Operating weight (base unit + return plenum) kg 29 + 7 44 + 10 46 + 10 4-pipe heating mode Resistance wire type, 230-1-50 ( 10%) Electric heater Heating capacity* kW 2.63 3.05 3.17 3.91 4.71 3.11 Heating capacity-excluding fan heat (+5%/ -10%) W 500 1000 2000 Electric heater capacity W 500 1000 1000 2000 2000 1000 Fan Centrifugal, forward curved blades ElectricalNumber data of centrifugal wheels 1 2 2 Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 at nominal air flow 230-1-50 Static pressure available return air plenum) 50 90 (unit without supply and Power input W 110 90Pa 104 50 140 50 197 Fan motor Current draw A 0.48 0.45 0.49 0.63 0.9 0.45 158 67 Weight Maximum absorbed power kg at 230 V35 51W 53 118 53 107 53 Fresh air connection Based onOutside high air diameter flow level. mm 125 125 125 * Based on standard Eurovent conditions: Constant minimum air flow (-10%, + 20%) l/s 8.3 8.3 8.3 Cooling 27C db/19C wb air temperature, 7C/12C entering/leaving water temperature. Constant maximum air flow (-10%, + 20%) l/s 44.4 44.4 44.4

DUCTED FAN COIL UNITS

31 162 (584) 60 4.85 3.38 2.3 0.23 (834) 305 31 6.1 3.2 5.56 46 + 10 3.25 2000 1000 230-1-50 50 104 0.49 220 69
125 8.3 44.4 2

32 219 (790) 65 6.28 4.43 3.1 0.30 (1080) 183 50 6.9 2.6 7.34 64 + 10 4.11 1000 2000
2 230-1-50 50 140 0.63 107 69 125 8.3 44.4

33 307 (1104) 51 7.85 5.61 3.2 0.38 (1350) 253 77 8.1 3.0 9.35 66 + 10 5.05 2000 2000
2 230-1-50 50 197

44 431 (1553) 71 10 7.62 3.3 0.48 (1720) 305 53 9.5 3.3 12.6 66 + 10 9.54 2000 2000
2 230-1-50 65 290

45 542 (1950) 56 11.8 9.18 0.56 (2030) 65

42EM ATMOSPHERA

15.2 11 2000 230-1-50 380 1.7 105

0.9 158 69
125 8.3 44.4

1.25 220 105


125 8.3 44.4

2-pipe heating: 20Con air temperature, entering temperature, same water flow rate as in cooling. 0 * Based an entering water 50C temperature of 7water C, entering air at 27C dry bulb and 47% relative humidity, and a water temperature difference of 5 K at maximum air flow and 0 Pa (Eurovent conditions). 4-pipe heating: 20Con air temperature, temperature. an entering water 70C/60C temperature entering/leaving of 50C, entering airwater at 20C and a water temperature difference of 10 K at maximum air flow and 0 Pa (Eurovent conditions). ** Based

Dimensions, mm Dimensions, mm
Non-ducted return air

Sizes 2 and 3 Ducted return air

Non-ducted return air

Note: Size 3 is also available with left-hand service access.

103

42EM

Size 1 Ducted return air

42GR - AIR TREATMENT MODULES

FEaTUREs
Two sizes with nominal air flows from 97 to 139 l/s for rooms from 30 to 50 m2 in area. Designed to heat or cool individual zones in multi-zone commercial, industrial or institutional buildings. Each zone has its own independent ducting system, reducing the risk of cross contamination. Speed controller Installed in a plant room to minimize transmission of noise and vibration from the unit to the conditioned space. Individual remote room control module mounted on a wall or desk. Can be equipped with Carrier numeric controller. Can be monitored and controlled by a central building management system via the Carrier Comfort Network. Variable-speed centrifugal fan. Can be shut down for servicing without affecting any other parts of the system. Quick-connect couplings for water and power supplies. Fresh air inlet with adjustable air quantity admits 8.3 to 16.6 l/s of ventilation air. One 42GR fan coil to control up to 31 more units. Compatibility with all Carrier linear air diffusers. Up to 300 Pa static pressure. Units shipped as two sub-assemblies for easy handling and installation. 42GR linear diffuser (supply and return air). High-efficiency air filtration system.

accEssoRIEs
Power Module for light, socket and blind operation. Mounting support package. Remote room control module. Wall mounting support. Electrical connectors. System configuration software. Fresh air controller.

104

Physical and electrical data


42GR Size 1 l/s kW kW kg V-ph-Hz kW 95 2.93 3.9 35 230-1-50 (15%) VDE, CE, UL and CSA codes approved 1.7 Centrifugal, backward curved single wheel, single inlet 320 Size 2 139 4.37 4.21 50 230-1-50 (15%) 1.8 Centrifugal, forward curved single wheel, double inlet 320 Nominal air flow Nominal cooling capacity* Total capacity Nominal heating capacity** Operating weight (6-row coil) Power supply PTC electric heater*** Maximum capacity at nom. air flow Fan Available static pressure at nom. air flow Fan motor Running current Max. power input at 230 V Fresh air connection Outside diameter Constant initial air flow (-10%, + 20%) A W mm l/s Pa

AIR TREATMENT MODULES 42GR

2 -pole open, asynchronous, protection class IP44, permanent capacitor, class B insulation, paint class F, connected to a speed controller 0.64 0.91 143 208 75 8.3 125 16.6

* Based on 6C water entering temperature, 250C db room air temperature, 50% relative humidity, 5 K t at nominal air flow. ** Based on 50C water entering temperature, 190C room temperature, 10 K t at nominal air flow. *** PTC - Positive temperature coefficient

Dimensions, mm
Standard installation

Air distribution with Carrier Optimix linear diffusers


Cooling air flow

Supply air
n sio en sp ing Su cas

Return air

Fresh air inlet

Heating air flow


Controller

88
105

42GR

42BJ - INDIVIDUAL COMFORT MODULES

FEaTUREs
Five sizes and three possible motor drive selections with nominal air flows from 144 to 264 l/s for individual rooms ranging in area from 25 m2 and 50 m2. Units include centrifugal fan, fresh air inlet with adjustable air quantity, throw-away filter, chilled water cooling coil and either hot water heating coil or electric resistance heater. Speed controller Air conditioning system comprises one or more Carrier air- or water-cooled chillers and one air handler. Fan coils may be installed above false ceilings or floor voids. Low noise level and high available static pressure. Can be equipped with a Carrier numeric controller. Fresh air inlet with a volume regulator offers precise control of the fresh air admitted. Units can also be monitored and controlled by a central building management system via the Carrier Comfort Network. High-efficiency filters (98% gravimetric). Modular design. Quiet centrifugal fan with a directly driven, variable-speed fan motor. Quick-connect couplings. Compatible with Carrier linear diffusers. Air purification system.

AccEssoRIEs
Electromechanical room thermostat for operation in heating mode only or cooling mode only. Electromechanical room thermostat for operation in heating mode and cooling mode (manual). Electromechanical room thermostat for operation in heating mode and cooling mode (automatic). Maestro Zone User Interface (ZUI) and Zone. User Interface base. Maestro wall-mounted thermostat. Room temperature sensor for Maestro Zone. Controller (ZC). Maestro Power Module (PM). Fresh air duct. Condensate drain pump. Adjustable feet for installing the 42BJ in a false floor.

Moduboot

Hot/cold water

106

42BJ 42BJ
INDIVIDUAL INDIVIDUALCOMFORT COMFORT MODULES MODULES
Physical Physicaland and electrical electrical data data
42BJ 42BJ Nominal air flow Nominal air flow Nominal coolingcapacity capacity cooling Nominal water coil** - cold water coil - cold Nominal heatingcapacity capacity Nominal heating - hot water coil** ** - hot water coil
Power supply supply Power

Size 1.3 Size 1.3 l/s l/s


kW kW kW kW V-ph-Hz V-ph-Hz kg

Size 2.3 Size 2.3 186 186


4.72 4.72 5.2 5.2

Size Size 4.4 4.4


229229 5.71 5.71 6.4 6.4

142 142
3.42 3.42 3.76 3.76 230-1-50 (10%) 230-1-50 (10%) 31

42BJ 42BJ

Operating weight (6-row coil and control) (6-row coil and control)
PTC electric heater*** PTC electriccapacity heater*** Maximum

Operating weight

kg

31 1.70

40

40 1.90

60

60 1.76

Maximum capacity Fan


Fan

kW

kW

VDE, CE, UL and CSA approved VDE, CE, UL and CSA approved 1.70 1.90 Centrifugal, single wheel, forward curved Centrifugal, forward single inlet single wheel, double inletcurved single inlet double inlet 142 186 120 120 142 186

1.76

Nominal air flow Static pressure air flow at nominal air flow Nominal

l/s Pa l/s

double inlet 229double inlet 120229

Static pressure at nominal air flow


Fan motor

Pa
W

Fan motor

Maximum power input at 230 V Fresh air connection Min./max. constant air flow (-10%, +20%)

2 poles, asynchronous, 230-1-50, with inherent overload protection, permanent capacitor, B, paint class F, IP44 with inherent overload protection, permanent capacitor, insulation 2 poles, class asynchronous, 230-1-50, 202 171 class F, IP44 insulation class B, paint240 Outside diameter 125 mm 8.3/44.4 8.3/44.4

120

120

120

Maximum power input at 230 V

W
l/s

202

240

171
8.3/44.4

Outside diameter 125 mm Fresh air connection constant air flow (-10%, +20%) l/s 8.3/44.4 Min./max. * Based upon water entering at 60C, room air at 250C dry bulb, 50% relative humidity, 58.3/44.4 K t and nominal air flow.
** Based upon water entering at 500C, room air at 190C, 10 K t and nominal air flow. PTC -upon Positive temperature coefficient * *** Based water entering at 60C, room air at 250C dry bulb, 50% relative humidity, 5 K t and nominal air flow.

8.3/44.4

** Based upon water entering at 500C, room air at 190C, 10 K t and nominal air flow. *** PTC - Positive temperature coefficient

Dimensions, mm 42BJ 1.3


A B 42BJ AC BD 900 450 1.3 600 900 270 450

2.3 1100 600 2.3 720 1100 270 600

4.4 1100 600 4.4 720 1100 345 600

Cooling air flow

Air distribution with Carrier Optimix linear diffusers

Cooling air flow

C D

600 270

720 270

720 345

Heating air flow


B A

Heating air flow


B

A
Hot/cold water Fresh air inlet

Moduboot

I.C.M.

90

90
107

42BJ

Dimensions, mm

Air distribution with Carrier Optimix linear diffusers

35BD - MODUBOOT LINEAR AIR DIFFUSERS

MODELS The Moduboot diffusers allow air throw adJustment according to the reQuired air flow.

35BD

FEaTUREs
Linear diffusers with high induction, specially designed to be connected to the Carrier 42GR Air Treatment Modules and 42BJ Individual Comfort Modules. Damper position of the Optimix diffuser changes automatically with the primary air temperature. Comprises a galvanized sheet metal plenum with 13mm thick fiberglass acoustic and thermal internal insulation. From fully cold to fully warm position, the damper operation providew adjusted air diffusion to ensure optimum comfort in the occupied space.

35SR

COMBINATIONS
42GR

42BJ-42BJ ULTRA

108

CHILLED 35BD - WATER TERMINALS


CHILLED WATER TERMINALS
35BD Moduboot linear diffusers dimensions, mm
35BD Type Nominal Length 600 1200 1500 600 1500 1200 1500 1500 1500 1500 1800 1800 A 575 1175 1475 575 1475 1175 1475 1475 1475 1475 1775 1775 B 600 1200 1500 600 1500 1200 1500 1500 1500 1500 1800 1800 C 539 1139 1439 539 1439 1139 1439 1439 1439 1439 1739 1739 D 530 1130 1430 530 1430 1130 1430 1430 1430 1430 1730 1730 F 122 122 122 122 122 122 140 150 122 122 140 150 G 74 74 74 74 74 74 92 112 74 74 92 112 H 270.5 270.5 270.5 281 281 281 281 281 281 281 281 281 I 152.4 152.4 152.4 162.8 162.8 162.8 162.8 162.8 162.8 162.8 162.8 162.8 J 159 159 159 L 76.2 76.2 76.2 101.5 115.8 115.8 130.0 144.25 115.8 115.8 130.0 144.25 M N

CHILLED WATER TERMINALS 35BD MODUBOOT

AG* Supply only

Supply and return


* 1 way or 2 way blow

AH* FH SH XH LH FH SH XH LH

199 199 199 199 199

867 867 1067 1067

563 563 663 663

Weight, Kg
Nominal length 600 1200 1500
* 1 way or 2 way blow

AG* 6.8 6.2 8.4

FH 7.1 6.5 8.6

SH 7.2 6.6 8.7

XH 7.0 9.1

LH 7.3 9.4

Supply air plenum 4 holes 7 dia Control end

Supply and return air plenum

A 1 0.5 ceiling with T-bars B 1 0.5 for continuous diffuser

Supply

Return

Typical one way diffuser AG-AH

Typical two way diffuser

Heat Cool XH slot diffuser

Cool

Heat FH slot diffuser

Cool

Heat

LH slot diffuser

Cool

Heat

Cool SH slot diffuser

92

109

35BD

hDB - ELEcTRINIc coNTRoLLER

ELECTRONIC CONTROLLER FOR FAN COIL UNITS

A ST
fiche .indd 3

EP TO

HDB

WAR D
FEATURES

S EN

HAN

CED

COM

The HDB controllers are compatible with the whole range of Carrier fan coil units.

Terminal fan coil unit grouping is possible by adding a simple communication board to each unit that permits control of up to 15 units via a communication bus.

FORT

Optimised comfort using an integrated microprocessor, designed to optimise the operation of the Carrier chilled-water fan coil units. Evident ease-of-installation. The controller is factory-installed and tested,10/04/08 making the on-site installation extremely simple. Choice of interfaces permits the building designer to select a wired wallmounted controller (CRC2)or an infrared remote control (IR2) that offers user comfort at the touch of a button. Daily programming is possible via the infrared remote control. Three start and stop schedules can be defined for each day. Control of the motorised louvres of the air distribution grilles from automatic positioning to continuous swing mode.

14:0

4:15

110

foR faN coIL UNITs

CONTROL ALGORITHMS On/off CONTROL VALVE MANAGEMENT Air flow control only (no valve) 230 V on/off motor FAN CONTROL Optimum fan speed selection Three speeds MAIN FUNCTIONS Setpoint control Occupied/unoccupied mode Frost protection mode Window contact input Measurement of entering water temperature for automatic changeover (2 pipes) Automatic operating mode changeover (4 pipes and 2 pipes/2 wires) Manual operating mode changeover Continuous ventilation within dead-band Periodical ventilation within dead-band Unit grouping

USER INTERFACE Digital display Automatic or manual fan speed control Operating mode selection Occupancy button (occupied/eco)

ELECTRONIC CONTROLLER FOR FAN COIL UNITS

A STEP TOWARDS ENHANCED COMFORT

fiche.indd 3

10/04/08 14:04:15

The HDB controllers are compatible with the whole range of Carrier fan coil units.

CENTRAL CONTROL, INDIVIDUAL COMFORT


TERMINAL FAN COIL UNIT GROUPING is possible
by adding a simple communication board to each unit that permits control of up to 15 units via a communication bus.

111

CHOICE OF INTERFACES permits the building


designer to select a wired wall-mounted controller (CRC2) or an infrared remote control (IR2) that offers user comfort at the touch of a button.

HDB

On-site configuration

hDB

Supply air louvre control

30RA/RH 005-015 - AIR-COOLED CHILLERS

CONTROLS

This new generation of chillers and heat pumps features the latest technological innovations, incorporating scroll compressors and operating with the ozone-friendly R-410A (005-013) or R-407C (015) refrigerant.

FEATURES
Compressors run very quietly and vibration-free and are known for their durability and reliability. Dedicated version for full integration with the Aquasmart system components. Electronic control system ensures intelligent control of the compressor start-up sequence, permitting operation at low system water volume. One or two axial fans with horizontal air discharge allow exceptional lownoise operation. Easy to install, extremely compact, with all hydronic components included in the unit. Condenser coils are made of copper tubes, mechanically expanded into aluminium fins, with an increased heat exchange surface.

ACCESSORIES/OPTIONS
Remote wall-mountable control. Standardised version. Service interface. Mechanical water filter. Crankcase heater. BMS filling system communication port. Coil protection grille.

112

30RA HEAT 005-015 PUMPS / 30RH 005-013

Physical data
Nominal cooling capacity* Nominal cooling capacity** Operating weight Refrigerant Compressor Evaporator Hydronic circuit Expansion tank volume Fans Quantity kW kW kg 30RA Cooling only model 005 007*** 009 5.1 6.7/6.5 7.6 71 73 85 30RH Heat pump 011 013 015 005 007*** 009 011 9.6 11.2 14.7 5.1 6.7/6.3 7.2 9.6 5.7 7.5/7.7 8.7 10.2 108 118 135 83 85 88 112 R-410A (sizes 005-015), R-407C (30RA 015) One scroll compressor One plate heat exchanger One three-speed pump (sizes 005-013), one single-speed pump (30RA 015) 2 2 2 2 1 2 3 3 Propeller fans 1 2 2 2 1 1 1 2 013 11.5 13.8 123

Ltr

1 1

1 1

3 2

* Based on an outdoor entering air temperature of 350C db, and a water heat exchanger entering/leaving water temperature of 120C/7C. ** Based on an outdoor entering air temperature of 70C db/60C wb, and a water heat exchanger entering/leaving water temperature of 400C/450C. *** The first value is for 230-1-50 units, the second value for 400-3-50 units.

Power Supply Nom. power input, cooling* Nom. power input, heating** Max. power input*** Full load current Water circulating pump Current drawn

V-ph kW kW kW A A

30RA Cooling only model 005 007 007 009 230-1 230-1 400-3 400-3 2.1 2.8 2.7 3.1 2.9 3.8 3.6 4.3 15 18 7.5 8.0 230-1-50 0.3 0.3 0.3 0.5

011 230-1 3.2 4.3 21.5 0.9

011 400-3 3.2 4.4 8.5 0.9

013 400-3 4.6 6.3 11.5 1.0

015 400-3 6.6 8.0 14.5 1.1

30RH Heat pump 005 007 007 230-1 230-1 400-3 2.0 2.6 2.6 2.2 2.9 2.9 2.8 4.0 3.9 14 18 6.5 0.3 0.5 0.5

009 400-3 3.0 3.4 4.3 6.5 0.5

011 230-1 3.3 3.7 5.2 19 0.9

011 400-3 3.3 3.7 4.9 8.0 0.9

013 400-3 4.6 5.0 6.7 11.5 1.0

* Based on an outdoor entering air temperature of 350C db, and a water heat exchanger entering/leaving water temperature of 120C/70C. ** Based on an outdoor entering air temperature of 70C db/60C wb, and a water heat exchanger entering/leaving water temperature of 400C/450C. *** Maximum power input at maximum operating conditions and worst power supply voltage.

Operating limits, cooling


Water start-up temperature 35C
Leaving water temperature, C

Operating limits, heating


Start-up leaving water temperature 10C
Leaving water temperature, C

Outdoor air temperature, C

Outdoor air temperature, C

Dimensions, mm
A B C mm mm mm 30RA Cooling only 005 007 800 800 590 590 300 300 009 800 803 300 011 800 1264 300 013 800 1264 300 015 800 1264 300 30RH Heat pump 005 007 800 800 803 803 300 300 009 800 803 300 011 800 1264 300 013 800 1264 300

Clearances, mm
*
B

C
* Power connection

113

30RA/RH 005-015

Electrical data

30RA/RH 017-033 - AIR - COOLED UNITS

CONTROLS

This new generation of chillers and heat pumps features the latest technological innovations, incorporating scroll compressors and operating with the ecological refrigerant HFC-407C. FEATURES
Compressors run very quietly and vibration-free and are known for their durability and reliability. Dedicated version for full integration with the Aquasmart system components. Two axial fans with horizontal air discharge allow exceptional low-noise operation.

PRO-DIALOG PLUS operator interface.

ACCESSORIES/OPTIONS
Remote wall-mountable control. Standardised version. Service interface. Mechanical water filter. BMS (CCN) communication port. Crankcase heater. BMS filling system communication port..

Pro-Dialog Plus control optimises the efficiency of the refrigerant circuit.

Pre-painted steel panels, removable for improved service and access to all components.

114

CHILLERS AND HEAT-PUMPS 30RA/RH 017-033


Physical data
Net cooling capacity* Net heating capacity** Operating weight Refrigerant Compressor Control type Water heat exchanger Hydronic circuit Pump Expansion tank water volume Air heat exchanger Fan Air flow
* **

kW kW kg

30RA Cooling only model 017 021 17.3 21.6 220 240

026 25.2 280

033 31.0 315 R-407C

30RH Heat pump 017 021 16.3 21.2 19.2 25.3 255 285

026 24.0 28.5 315

033 28.3 34.8 345

One scroll compressor Pro-Dialog Plus One plate heat exchanger Pump, screen filter, expansion tank, pressure gauge, purge valve, flow switch and flow control 8 8 8 One single-speed, 230-1-50 8 8 Two propeller fans 3000 2222 8 8 8

One, copper tubes, pre-treated aluminium fins

Based on an outdoor entering air temperature of 350C db, and a water heat exchanger entering/leaving water temperature of 120C/70C. Based on an outdoor entering air temperature of 70C db/60C wb, and a water heat exchanger entering/leaving water temperature of 400C/450C.

Electrical data
Power Supply Nom. power input cooling/heating* Nominal current drawn** Starting current Pump power input
* **

V-ph-Hz kW A A kW

30RA Cooling only model 017 021 026 400-3-50 10% 6.87 9.11 9.56 10.75 15.50 18.80 87 132 134 0.65 0.68 0.89

033 10.40 24.55 139 0.93

30RH Heat pump 017 021 6.68/7.43 10.75 87 0.65 8.53/9.24 14.80 132 0.68

026 9.86/10.70 18.70 134 0.89

033 12.70/13.50 23.65 139 0.93

Based on an outdoor entering air temperature of 350C db, and a water heat exchanger entering/leaving water temperature of 120C/70C. Based on an outdoor entering air temperature of 460C db, and a water heat exchanger leaving water temperature of 100C.

Operating range
50 46 42 38 34 30 26 22 18 14 10 6 2 -2 -6 -10 -14

Dimensions, mm
Cooling
A B C 30RA Cooling only model 017 021 026 1328 1328 1503 478 478 478 1383 1383 1587 033 1503 478 1587 30RH Heat pump 017 021 026 1328 1503 1503 478 478 478 1383 1587 1587 033 1503 478 1587

Outdoor air temperature 0C

-1

10

11 12

13

14

Leaving water temperature 0C Heating

25

Outdoor air temperature 0C

20 15 10 5 0 -5 -10 -15 20 25 30 35 40 45 50 55

Leaving water temperature 0C

A
Operating range with anti-freeze solution and with special configuration of the Pro-Dialog control system.

115

30RA/RH 017-033

l/s

2450

2222

3278

3611

3111

3333

30RA/RH 040-160 - AIR COOLED UNITS

CONTROLS

This new generation of chillers and heat pumps features the latest technological innovations, incorporating scroll compressors and operating with the ozone-friendly refrigerant HFC-407C FEATURES
Integrated hydronic module for fast installation, incorporating all hydronic components. Low-volume water loop: the auto-adaptive algorithm controls the water temperature and eliminates any risk of excessive compressor cycling.

PRO-DIALOG Plus.

ACCESSORIES/OPTIONS
Condenser anti-corrosion pre-treatment. Electronic compressor starter. Unit without hydronic module. Hydronic module with dual pump. Communications board with open JBus protocol.

The patented receiver/heat exchanger ensures operation with the ideal refrigerant charge (30RH units only).

Low-noise, two speed Flying Bird II fan not fixed to the top unit panel, but supported by an extremely rigid tower chassis.

Defrost is optimised by the auto-adaptive algorithm.

Quiet, vibration-free scroll compressors, durable and maintenance-free.

116

CHILLERS HEAT 30RA/RH AND 040-240 - PUMPS

30RA/RH 040-240 -

Physical Physical data Physical data data


040 070 080 040 050 080 090 100 040 050 050 060 060 060 070 070 080 090 100 090 120 120 100 140 140 040 050 49.0 57.0 060 57.0 67.0 070 080 090 100 89.0 115.0 120 97.0135.0 140 kW 39.4 67.0 79.0 kW 39.4 49.0 79.0 89.0 97.0 kW 39.4 49.0 57.0 67.0 79.0 89.0 97.0 115.0 135.0 Nominalweight cooling capacity* kW 39.4 49.0 57.0 67.0 79.0 89.0 97.0 115.0 135.0 Operating with hydronic Operating Operating weight weight with with hydronic hydronic module module module and single pump kg 256 611 631 1093 1205 526 584 631 1093 1106 Operating weight with hydronic module kg and pump kg 526 584584 597 597 597 611 611 631 1093 1106 1205 11061212 1212 single pump and single kg 526 584 050 060 597 060 070 611 631 1093 1106 1205 100 140 1212 and single pump 30RH 040 070 080 30RH 040 050 080 090 100 30RH 040 050 060 070 080 090 100 090 120 120 140 30RH cooling 040 050 44.5 54.0 060 54.066.0 070 080 090 100 83.0 108.0 120 92.0132.0 140 Nominal capacity* kW 38.3 66.0 71.0 Nominal capacity* kW 38.3 44.5 71.0 83.0 92.0 Nominal cooling cooling capacity* kW 38.3 44.5 54.0 66.0 71.0 83.0 92.0 108.0 132.0 Nominal cooling capacity* kW 38.3 44.5 54.0 58.067.0 66.0 71.0 83.0 92.087.0 117.0 108.0 98.0133.0 132.0 Nominal heating capacity** kW 39.2 47.3 58.0 67.0 80.0 Nominal heating capacity** kW 39.2 47.3 80.0 87.0 98.0 Nominal heating capacity** kW 39.2 47.3 58.0 67.0 80.0 87.0 98.0 117.0 133.0 heating capacity** Nominalweight kW 39.2 47.3 58.0 67.0 80.0 87.0 98.0 117.0 133.0 Operating with hydronic Operating with hydronic Operating weight weight with hydronic module module Operating weight with hydronic module kg module and single pump kg 566 661 691 1183 1238 pump and 566 624 691 1183 1196 single pump and single kg 566 624624 647 647 647 661 661 691 1183 1196 1238 11961312 1312 and single pump kg 566 624 647 661 691 1183 1196 1238 1312 Refrigerant Refrigerant R-407C Refrigerant R-407C R-470C Refrigerant R-407Cscroll compressor Compressors Hermetic Compressors Hermetic r/s scroll compressor, compressor, 48.3 48.348.3 r/s r/s Compressors Hermetic scroll Compressors Hermetic scroll compressor, 48.3 fins r/s fins Outdoor coil Grooved copper aluminium aluminium Outdoor Grooved Outdoor coil coil Grooved copper copper tubes, tubes, tubes, aluminium fins Outdoor coil Grooved copper tubes, aluminium fins Fans Axial Flying Bird fans with rotating shroud Bird fans with rotating shroud Fans Axial Flying Bird fans with rotating shroud Fans Axial Flying DirectBird expansion welded plate heat exchanger Indoor fans with rotating shroud Fanscoil Axial Flying Indoor Direct-expansion Indoor coil coil Direct-expansion welded welded plate plate heat heat exchanger exchanger With single centrifugal monocell pump, 48.3 r/s Hydronic Indoor module coil Direct-expansion welded plate heat exchanger Hydronic With module single centrifugal centrifugal monocell monocell pump, pump, 48.3 48.3 r/s r/s Hydronic module With single module single Hydronic With 00 00 0 0 centrifugal monocell pump, 48.3 r/s * Nominal conditions: water heat exchanger entering/leaving temperature 12 C/7 C, outdoor air temperature 35 C.

30RA cooling Nominal capacity* Nominal capacity* Nominal cooling cooling capacity*

30RA 30RA 30RA

Physical data

160 115.0 157.0 157.0 157.0


1205 1248 1248

120 160 160

CHILLERS AND HEAT PUMPS 30RA/RH 30RA/RH 040-240 CHILLERS AND HEAT PUMPS 040-240 CHILLERS AND HEAT PUMPS 30RA/RH 040-240

140 200 200 200 135.0 202.0 202.0 202.0 1212 2133 2133 2133 140 200 200 200 132.0 179.0 179.0 179.0 133.0 194.0 194.0 194.0 1312 2233 2233 2233

240 240 160 240157.0 245.0 245.0 245.0


1248 2305 2305 2305 240 240 160 240142.0 210.0 210.0 210.0 160.0 229.0 229.0 229.0 1368 2405 2405 2405

142.0 117.0. 160.0 160.0 160.0 1368


1238 1368 1368

160 108.0 142.0 142.0

1248 120 160 160

* ** * ** **

Nominal conditions: water heat exchanger entering/leaving temperature 12 C/7 C, outdoor air temperature 35 C. 00 0 00 0 00 Nominal exchanger entering/leaving temperature 40 C/45 C, outdoor air dry bulb water heat exchanger entering/leaving temperature C/7 C, outdoor air temperature 350C. 7 Nominalconditions: conditions:air airheat heat exchanger entering/leaving temperature 4012 C/45 C, outdoor air dry bulbtemperature temperature 7C. C. Nominal conditions: air heat exchanger entering/leaving temperature 400C/450C, outdoor air dry bulb temperature 70C.

Electrical data data Electrical

Electrical Electrical data data


30RA (without hydronic module) 040 050 080 090 100 160 200 240 040 050 050 060 060 060070 070 080 090 100 090 120 120 100140 140 160 200 240 160 040 070 080 120 140 30RA (without hydronic module) 040 050 060 070 080 090 100 120 140 160 200 240 Power circuit circuit Power Power circuit Power circuit Nominal power supply V-ph-Hz 400-3-50 Nominal power supply V-ph-Hz 400-3-50 10% 10% Nominal power supply V-ph-Hz 400-3-5010% Nominalcircuit power supply V-ph-Hz 400-3-50 10% Control supply The control circuit is supplied via the unit-mounted transformer circuit supply control circuit is supplied via the unit-mounted transformer Control The Control circuit supply The control circuit is supplied via the unit mounted transformer supply control39.9 circuit is supplied via the unit-mounted transformer Control circuit The Maximum unit power input* kW 20.3 24.6 30.1 35.2 44.1 49.6 60.5 70.6 79.6 104.2 124.9 Maximum unit power input* kW 20.3 24.6 39.9 44.1 49.6 79.6 104.2 124.9 Maximum unit power input* kW 20.3 24.6 30.1 30.1 35.2 35.2 39.9 44.1 60.5 49.6 70.6 60.5 70.6 79.6 Maximum unit power input* kW 20.3 24.6 30.1 35.2 39.9 44.1 49.6 60.5 70.6 79.6 104.2 124.9 Nominal unit current draw** A 27.9 34.7 41.1 47.0 54.3 62.7 69.1 82.3 94.1 108.6 140.2 168.7 unit current draw** Nominal A 27.9 34.7 41.1 47.0 54.3 62.7 69.1 82.3 94.1 108.6 140.2 168.7 Nominal unit current draw** A 27.9 34.7 41.1 47.0 54.3 62.7 69.1 82.3 94.1 108.6 current draw** Nominal unit A 27.9 34.7 41.1 47.0 54.3 62.7 69.1 82.3 94.1 108.6 140.2 168.7 start-up current*** Maximum A 158.4 151.0 168.9 176.1 190.4 199.8 208.1 218.6 233.0 256.1 293.4 327.6 start-up current*** Maximum AA 158.4 151.0 190.4 199.8 208.1 256.1 293.4 327.6 Maximum start-up current*** 158.4 151.0 168.9168.9176.1 176.1 190.4 199.8 218.6 208.1233.0 218.6 233.0 256.1 Maximum start-up current*** A 158.4 151.0 168.9 176.1 190.4 199.8 208.1 218.6 233.0 256.1 293.4 327.6 30RH (without hydronic module) 040 050 060 070 080 090 100 120 140 160 200 240 30RH (without hydronic module) 040 050 060 070 080 090 100 120 140 160 200 240 160 30RH (without hydronic module) 040 050 060 070 080 090 100 120 140 30RH (without hydronic module) 040 050 060 070 080 090 100 120 140 160 200 240 Power circuit Power circuit Power circuit Power circuit Nominal power supply V-ph-Hz 400-3-50 10% Nominal power supply V-ph-Hz 400-3-50 10% Nominal power supply V-ph-Hz 400-3-5010% Nominalcircuit power supply V-ph-Hz 400-3-50 10% Control supply The circuit is via unit-mounted transformer Control circuit supply The control control circuit is supplied supplied via the the unit-mounted transformer Control circuit supply The control circuit is supplied via the unit mounted transformer Control circuit supply The control circuit is supplied via the unit-mounted transformer Maximum unit power input* kW 20.3 24.6 30.1 35.2 40.0 44.2 49.6 60.5 70.7 79.7 104.3 124.9 Maximum unit power input* kW 20.3 24.6 40.0 44.2 49.6 79.7 104.3 124.9 Maximum unit power input* kW 20.3 24.6 30.1 30.1 35.2 35.2 40.0 44.2 60.5 49.6 70.7 60.5 70.7 79.7 Maximum unit powerdraw** input* kW 20.3 24.6 30.1 35.2 40.0 44.2 49.6 60.5 70.7 79.7 104.3 124.9 Nominal unit current A 28.0 34.7 54.3 62.7 69.1 108.6 140.3 168.7 Nominal unit current draw** AA 28.0 34.7 41.2 41.247.0 47.0 54.3 62.7 69.1 82.3 69.194.1 94.1 108.6 140.3 168.7 Nominal unit current draw** 28.0 34.7 41.2 47.0 54.3 62.7 82.3 82.3 94.1 108.6 Nominal unit current draw** A 28.0 34.7 41.2 47.0 54.3 62.7 69.1 82.3 94.1 108.6 140.3 168.7 Maximum start-up current*** A 158.4 151.0 176.1 190.4 199.8 208.1 233.0 256.1 293.4 327.6 Maximum start-up current*** AA 158.4 151.0 168.9168.9 176.1 176.1 190.4 199.8 208.1 218.6 208.1 233.0 218.6 256.1 293.4 327.6 Maximum start-up current*** 158.4 151.0 168.9 190.4 199.8 218.6 233.0 256.1 Maximum start-up current*** A 158.4 151.0 168.9 176.1 190.4 199.8 0 208.1 218.6 233.0 256.1 293.4 327.6 00 0 * Power input of the compressor(s) + fan(s) at maximum unit operating conditions: entering/leaving water temperature = 150C/10 C, maximum condensing temperature of 67.80C, and 400 V nominal 30RA (without hydronic module) 30RA (without hydronic module)

* * ** ** ** *** *** ***

Power input of the compressor(s) + fan(s) at maximum unit operating conditions: entering/leaving water temperature = 15 C/10 C, maximum condensing temperature of 67.8 C, and 400 V nominal voltage (values given on plate). Power input of the compressor(s) + fan(s) at maximum unit operating conditions: entering/leaving water temperature = 150C/100C, maximum condensing temperature of 67.80C, and 400 V nominal voltage (values given onthe theunit unitname name plate). 00 00 00 Nominal unit at the conditions: voltage (values given draw on the unit name plate). Nominal unitcurrent current draw at thefollowing following conditions:evaporator evaporatorentering/leaving entering/leavingwater watertemperature temperature12 12C/7 C/7C, C,outdoor outdoorair airtemperature temperature35 35C. C.The Thecurrent currentvalues valuesare aregiven givenat at400 400V Vnominal nominalvoltage voltage (values on plate). Nominal unit current draw at the following conditions: evaporator entering/leaving water temperature 120C/70C, outdoor air temperature 350C. The current values are given at 400 V nominal voltage (valuesgiven given onthe theunit unitname name plate). at 400 V nominal voltage and with compressor in across-the-line start (maximum operating current of the smallest compressors + fan current + locked Maximum instantaneous starting current (values given on the unit name plate). Maximum instantaneous starting current at 400 V nominal voltage and with compressor in across-the-line start (maximum operating current of the smallest compressors + fan current + locked rotor of compressor). current at 400 V nominal voltage and with compressor in across-the-line start (maximum operating current of the smallest compressors + fan current + locked Maximum instantaneous starting rotorcurrent current ofthe thelargest largest compressor). rotor current of the largest compressor).

Hydronic module Single pump/dual pump Single pump/dual pump Single pump/dual pump Single pump/dual pump Shaft power Shaft power Shaft power Shaft input* power Power Power Power input* input*

Hydronic module Hydronic module Hydronic module

040 040 040 040

050 050 050 050


0.75/2.2 0.75/2.2 0.75/2.2 0.75/2.2 1.1/2.7 1.1/2.7 1.1/2.7 1.1/2.7 2.1/4.7 2.1/4.7 2.1/4.7 2.1/4.7

060 060 060

060 070 070

070

070 080 080

080

080 090 090 090 1.1/2.2 1.1/2.2 1.1/2.2 1.1/2.2 1.4/2.7 1.4/2.7 1.4/2.7 1.4/2.7 3.1/4.7 3.1/4.7 3.1/4.7 3.1/4.7

100 100 090 120 120 100 120


1.1/2.2 1.1/2.2 1.1/2.2 1.1/2.2 1.4/2.7 1.4/2.7 1.4/2.7 1.4/2.7 3.1/4.7 3.1/4.7 3.1/4.7 3.1/4.7

100140 140

140

120 160 160

160

140 200 200 200

240 240 160 240

kW 0.75/2.2 kW 0.75/2.2 kW 0.75/2.2 kW 0.75/2.2 kW 1.1/2.7 kW 1.1/2.7 kW 1.1/2.7 Power input* kW 1.1/2.7 Maximum current draw at 400V** 2.1/4.7 Maximum current draw at A 2.1/4.7 Maximum current draw at 400 400 V** V** AA 2.1/4.7 Maximum current draw at 400 V** A 2.1/4.7 Note: The water pump power input values are given for guidance only.

Note: The water pump power input values are given for guidance only. * To maximum power input for with hydronic module Note: The waterthe pump power input values given guidance only. * Toobtain obtain the maximum power inputare fora aunit unitfor with hydronic moduleadd addthe themaximum maximumunit unitpower powerinput inputfrom fromthe thetop toptable tableto tothe thepump pumppower powerinput input(*) (*)from fromthe thetable tableabove. above. ** current for with add the maximum unit current draw from top to pump draw from the * power input for a unit draw with hydronic module add themodule maximum unit input from the top table to the power input (*) current from the table above. ** To Toobtain obtainthe themaximum maximumunit unitoperating operating current draw foraaunit unit withhydronic hydronic module add thepower maximum unit current draw from thepump toptable table tothe the pump current draw from thetable tableabove. above. ** To obtain the maximum unit operating current draw for a unit with hydronic module add the maximum unit current draw from the top table to the pump current draw from the table above.

0.75/2.2 0.75/2.2 0.75/2.2 0.75/2.2 1.1/2.2 0.75/2.2 0.75/2.2 1.1/2.2 0.75/2.2 0.75/2.21.1/2.7 1.1/2.2 1.1/2.7 1.1/2.7 1.1/2.7 1.1/2.7 1.1/2.7 1.4/2.7 1.4/2.7 1.1/2.7 1.1/2.7 2.1/4.7 1.4/2.7 2.1/4.7 2.1/4.7 2.1/4.7 2.1/4.7 2.1/4.7 3.1/4.7 3.1/4.7 2.1/4.7 2.1/4.7 3.1/4.7

1.1/2.2 1.85/3.0 1.85/3.0 1.85/3.0 1.85/3.0 1.85/3.0 1.85/3.0 1.85/3.0 1.85/3.0 1.85/3.02.5/4.0 1.85/3.0 1.4/2.7 2.5/4.0 2.5/4.0 2.5/4.0 2.5/4.0 2.5/4.0 2.5/4.0 2.5/4.0 2.5/4.0 5.0/6.6 2.5/4.0 3.1/4.7 5.0/6.6 5.0/6.6 5.0/6.6 5.0/6.6 5.0/6.6 5.0/6.6 5.0/6.6 5.0/6.6 5.0/6.6

1.85/3.0 1.85/3.0 5.5/5.5 5.5/5.5 5.5/5.5 5.5/5.5 5.5/5.5 5.5/5.5 2.5/4.0 2.5/4.0 6.6/6.6 6.6/6.6 6.6/6.6 6.6/6.6 6.6/6.6 6.6/6.6 5.0/6.6 5.0/6.6 10.9/10.9 10.9/10.9 10.9/10.9 10.9/10.9 10.9/10.9 10.9/10.9

Dimensions, Dimensions, mm mm Dimensions, mm


1329 (040-160) 1329 (040-160) 1329 (040-160) 1329 (040-160) 1674 (200-240) 1674 (200-240) 1674 (200-240)

Operating Operating range range Operating range


Cooling Cooling mode mode Cooling mode

Heating Heating mode mode Heating mode


Entering air temperature temperature Entering air air temperature Entering

1 08 1 1 (040 0 1 08 1 8 1(( -0 0 2 4 8 0 2 0 0 4 7 -)0) 2 0 81(0 0 2 8 1 2 7 0 0 2 8 8 99 8 7 0 0) 8(0 -1 0 0 4 9 -6 ) 2 0 4 227 (0 0 2 00 8 4 )

8 (090 0) -240)

) ) 60 600 ) ) 0-1 116 )00 -00 04 44 44 ) 0 ( 22 6 1 (( 0 1 7 0 0 0 240) 0 0 11 (4 20 77 0 2 0 (2 00 1 22 55(1 (200 1 33 7 33 20 51 3 3

Entering air temperature temperature Entering air air temperature Entering

Notes: Notes: 1. tt= Notes: =5 5K K 1. Water Waterheat heatexchanger exchanger 00 2. exchanger 1. Water heatheat exchanger t =and 5 Kthe 2. The Thewater water heat exchanger and thehydronic hydroniccircuit circuitpump pumpare areprotected protectedagainst againstfrost frostdown downto to-20 -20C. C. 2. The water heat exchanger and the hydronic circuit pump are protected against frost down to -200C. configuration solution and special Pro-Dialog control anti-freeze Operating range with required Operating range with required anti-freeze solution and special Pro-Dialog control configuration Operating range with required anti-freeze solution and special Pro-Dialog control configuration

Leaving Leavingwater watertemperature temperature Leaving water temperature

Leaving Leavingwater watertemperature temperature Leaving water temperature

117

30RA/RH 040-160

30RHX - HIGH EFFICIENCY AIR TO WATER

FEaTUREs
Four sizes with nominal cooling capacities from 4.5 to 10.8 kW (fan coil application) or 6.5 to 15.4 kW (floor heating application) and nominal heating capacities from 5.8 to 14 kW (fan coil application) or 6.4 to 14.5 kW (floor heating application). Designed for space heating and cooling and suitable for both fan coil and floor heating applications. Units incorporate scroll compressors and operate on the ozone-friendly refrigerant HFC-410A. Electronic, microprocessor-based auto-adaptive control system ensures intelligent control of the compressor start-up sequence, permitting operation at low system water volumes. Components are specifically designed for R-410A refrigerant. All units have been submitted to the necessary laboratory tests to ensure perfect operation. One or two two-speed axial fans with horizontal air discharge. The advanced design allows exceptionally low-noise operation. Sizes 008 and 011 are equipped with a soft starter device to limit the starting current. Pro-Dialog Junior control system controls start/stop, temperature selection, alarm code display functions. Compact unit dimensions and reduced weight facilitate installation. Galvanised steel panels ensure increased weather resistance. Removable panels for improved service and easier access to the internal components. Condenser coils are made of copper tubes, mechanically expanded into aluminium fins, with an increased heat exchange surface. Refrigerant-to-water heat exchangers are plate heat exchangers, ensuring optimum heat transfer at reduced dimensions. Scroll compressors run very quietly and vibration-free and are known for their durability and reliability. Microprocessor-controlled automatic outdoor heat exchanger defrost cycles allow the unit to operate with high efficiency at low outdoor temperatures.
1278 803

Pro-Dialog Junior operator interface.

DIMENSIONS, mm
1103

30RHX 011-15

30RHX 006, 008

CLEARANCES, mm

118

30 0

800

333

HEAT PUMPS
Physical data Physical data Fan coil Fan coilapplication application
30RHX

30RHV HIGH-EFFICIENCY 30RHV AIR-TO-WATER HEAT PUMPS


HIGH-EFFICIENCY AIR-TO-WATER HEAT PUMPS
30RHV 006 kW kW kW kW kW kW kg kW kW kg
kW kW 006

008 6.1 008 8.05 6.1 8.6 8.05 8.35

008

011

011

15

HIGH-EFFICIENCY AIR-TO-WATER HEAT PUMPS 30RHV HIGH-EFFICIENCY AIR-TO-WATER HEAT PUMPS 30RHV

coolingcapacity* capacity* Nominal Nominal cooling 30RHV Nominal heating capacity** Nominal capacity** application Fan coilheating Floor heating application Nominal cooling capacity* Floor heating application Nominal capacity*** Nominalcooling heating capacity** heating capacity**** Nominal Nominal cooling capacity*** Floor heating application Nominal heating capacity****. weight Operating cooling capacity*** Nominal Nominal heating Operating weight capacity**** Refrigerant type Refrigerant Operatingtype weight Compressor Compressor Refrigerant type heat exchanger Refrigerant-to-water Refrigerant-to-water heat exchanger Compressor Hydraulic circuit Hydraulic circuit inlet/outletconnections connections Water heat exchanger Refrigerant-to-water Water inlet/outlet
Fans Fans Hydraulic circuit Number of fans/diameter Water inlet/outlet connections Number of fans/diameter

4.4 006 6.0 4.4 6.1 6.0 6.2 85 6.1 6.2 85

4,4 6,0

6,1 8,05

8.4 8,4 011 10.2

10,8 14

kW kW kg

6,1 6,2 85

8,6 8,35

8.4 11.8 10.2 10.9 11,8 112 11.8 10,9

10,2

15,4 14,5 143

88 8.6 8.35 88 10.9 112 R-410A R-410A 112 88 One scroll compressor One scroll compressor R-410A One plate heat exchanger One plate heat exchanger One scroll compressor 1
1

in mm in mm

in

1 1/370 1 1/370

1 exchanger 1 One plate heat 1 1/370 1 1/370 1/370 008 008 230-1-50 230-1-50 207-253 008 207-253 230-1-50 2.77 207-253 3.15 2,74
2,53 2.77 2,75 2,03 011-7

mm

1/370

2/370 * 1 2/500 2/370* 011-7 011-9 230-1-50 230-1-50 400-3-50 207-253 207-253 011-7 360-440 230-1-50 3.36 207-253 3.52 3,35 3,35
3,25

2/500

Fans of fans/diameter Number Electrical data 30RHV 30RHX Electrical data Power supply Power supply Voltage range 30RHV Voltage range coil supply application Fan Power Fan coil application input, cooling* Power Voltage range Power input, heating** Power input cooling* Fan coil application Power input heating** Floor heating application Power input, cooling* Power input, cooling*** Power input, heating** Floor heating application Power input, heating**** Power cooling*** Floor input heating application Maximum power input Power input, cooling*** Power input heating**** Power input, heating**** Locked rotor current Maximum power input+ Full load current Maximum power input Fan motor (230-1-50) Locked rotor current Full load current Current drawn Full load current Compressor crankcase heater (230-1-50) Fan motor (230-1-50) Current drawn Current Currentdrawn drawn
Compressor crankcase heater (230-1-50) Fan motor (230-1-50) Locked rotor current

V-ph-Hz V V-ph-Hz kW V kW kW kW kW kW kW kW kW A kW kW A A kW A A

V-ph-Hz V

kW kW

kW kW kW A kW

2.00 2,00 2.03 2.40 1.77 2.90 2.03 1,64 1.77 58 2,90 16 2.90
56 11 2,24

2.91 3.15 2.49

3.53 2.91 2.49 82 3,53 19 3.53


82

3,65 2,64 4,20 97 19

3.36 3.48 3.52 3.03 4.70 3.48 3.03 97 23 4.70 97 1.64 23 0.11 1.64 0.11

3,25

3,65 2,64 4,20 46 26

3.364,30 3.48 3.52 3.03 4.20 3.48 3,55 3.03 48 10 4.20


60 5,05

58 0.82 16

1.10 19
0,93 0.11

82 17

48 28 1.64 10
1,22 0.11 1.64

0,79 0.11 0.82

1.10

1,12

1,12

*Compressor Based on: crankcase evaporator entering/leaving water temperature 12C/7C, condenser entering air temperature of 35C. heater (230-1-50) ** Based on: condenser entering/leaving water temperature 40C/45C, evaporator temperature wb. Current drawn Aentering air 0,11 of 7C db/6C 0,11 0.11 0.11 Current drawn A *** Based on: evaporator entering/leaving water temperature 23C/18C, condenser entering air temperature of 35C. **** Based on: condenser entering/leaving water temperature 30C/35C, evaporator entering air temperature of 7C db/6C wb. Based on:unit evaporator entering/leaving water temperature 12C/7C, condenser entering air temperature of 35C. * Maximum power input at maximum operating conditions and worst power supply voltage ** Based on: condenser entering/leaving water temperature 40C/45C, evaporator entering air temperature of 7C db/6C wb. *** Based on: evaporator entering/leaving water temperature 23C/18C, condenser entering air temperature of 35C. **** Based on: condenser entering/leaving water temperature 30C/35C, evaporator entering air temperature of 7C db/6C wb. Maximum unit power input at maximum operating conditions and worst power supply voltage

0,11

0,11

0.110,11

Operating limits

Operating limits Start-up leaving water temperature 35C max.


20 18 55

Operating range - cooling

Operating range - heating Start-up leaving water temperature 3C min.


50

Leaving water temperature, Leaving water temperature C C Leaving water temperature, Leaving water temperature C C

water temperature, C Leaving temperature, C Leaving water

16 20 14 18 12 16 10 14 8 12 6 10 4 2 0 8 6 4 -15 2 0 -15 -10 -10

Operating range - cooling Start-up leaving water temperature 35C max.

-5

10

15

20

25

30

35

40

45

Outdoor air temperature C C Outdoor air temperature, -5 0 5 10 15 20 25 30 35 40 45

45 55 40 50 35 45 30 40 25 35 20 30 15 25 10 20 5 15 0 10 -15 5 0

Operating range - heating Start-up leaving water temperature 3C min.

-12

-9

-6

Outdoor air temperature, C Outdoor air temperature, C


-3 0 3 6 9

-3

12

15

18

21

24

Outdoor air temperature C C Outdoor air temperature,

-15

-12

-9

-6

12

15

18

21

24

119

30RHX

006 006 230-1-50 230-1-50 207-253 006 207-253 230-1-50 2.00 207-253 2.40 2,00

011-9 015-9 400-3-50 400-3-50 360-440 011-9 360-440 400-3-50 3.36 360-440 3.52 4,45

30RB 182-802 - AIR COOLED LIQUID

CONTROLS

FEaTUREs
Fifteen sizes with nominal cooling capacities from 173 to 758 kW. State-of-the-art Aquasnap Puron liquid chillers featuring the latest technological innovations and operating on the ozone-friendly refrigerant R410A. Integrated hydronic module with water pump and expansion tank.

Pro-Dialog Plus operator interface.

OpTIoNs aND accEssoRIEs


Euro Pack: enclosure panels, evaporator frost protection, main disconnect switch and low noise level.* Special condenser treatments. * Suction shut-off valves. * Enclosure panels on each end of the coils. * Grilles on all four unit faces. * Evaporator and hydronic module with aluminium jacket - 262-522. * High and low-pressure single or dualpump hydronic modules - 262-522. * Evaporator frost protection. * Winter operation .* Low and very low noise levels. * Twinning * Heat reclaim condenser sizes 262-522. * Main disconnect switch with or without fuse. * JBus or LonTalk gateways. * Energy Management Module EMM. *** Connection sleeve .** Scrolling Marquee Interface. ** Power cable connection side extension. ** Electronic starter 262-522. * DX free cooling system 262-522. * IP54 protection* .
* Option ** Accessory *** Option/Accessory

Low-noise scroll compressors with low vibration levels.

V-shaped condenser coils, allowing quieter air flow across the coil.

Simplified electrical connections.

Fast commissioning, as all units are systematically run tested before shipment. Economical operation with increased energy efficiency at part load and dynamic superheat management. Auto-adaptive control algorithm and automatic compressor unloading for increased reliability.

Exceptional endurance tests.

120

02

CHILLERS WITH INTEGRATED HYDRONIC MODULE

RS WITH INTEGRATED HYDRONIC MODULE


Physical data
30RB Nominal cooling capacity* kW 182 173 202 193 232 227 262 263 302 293 2760 732 342 328 2956 802 372 359 2984 R410A 402 391 3110 432 418 3632 462 447 3772 522 506 3930 602 596 5120 672 652 5289 732 704 5960 802 758 6120

262 kW kg kg kg 256 2320 2510 2755 R410A

unit 302 Operating 342 weight** 372standard 402

291 Refrigerant 325

432 415 3860 4160 4505

kg 462

1902 2180 522 2002 6022012 672

2920 3120 3160 Control 3360 3465 Quantity 3665


Fans

Compressors Condensers

356 3180 3440 3785

388 3310 3570 3915

444 4000 4300 4695


l/s

503 4190 4510

593 5440 5810

648 5640 6020 -

700 6320 6740

753

Hermetic scroll, 48.3 r/s 6510 Pro-Dialog Plus 6950

4 4925 4 18056 18056

4 18056

4 18056

Grooved copper tubes and aluminium fins Axial FLYING BIRD IV with rotating shroud -5 5 6 6 7 22569 22569 27083 27083 31597 Direct expansion, shell-and-tube

7 31597

8 36111

9 40625

10 45139

11 49653

12 54167

l/s

Pro-Dialog Plus Hydronic module (option) Centrifugal, monocell, low or high presseure (as required) Grooved copper Water tubespump and aluminium fins Single or twinned dual pump (as required) Axial FLYING BIRD IV with rotating shroud 4 5 5 6 6 7 7 8 9 10 11 12 * Nominal conditions: evaporator entering/leaving water temperature 12C/7C, outside air temperature 35C, evaporator fouling factor 0.000018 m K/W 18056 22569 22569 27083 31597 31597 36111 40625 45139 49653 54167 ** Weights are for guidance27083 only Direct expansion, shell-and-tube Centrifugal, monocell, low or high pressure (as required) Single or twinned dual pump (as required)
30RB (without hydronic module) Power circuit Nominal power supply Control circuit supply V-ph-Hz 400-3-50 24 V, via internal transformer 182 202 232 262 302 342 372 402 432 462 522 602 672 732 802

Hermetic scroll, 48.3 r/s Evaporator

Total air flow

g/leaving water temperature 12C/7C, outside air temperature 35C, evaporator fouling factor 0.000018 m2 K/W

262

302 Maximum 342 unit power 372 input*402


Circuits A + B/C

432

462
kW A 85

522
98 129

602
102 135

672
127 167

732
140 185 159 209

802
172 226 191 251 535 204 269 557 223 293 590 255 334 645 191/96 191/127 255/96 255/127

-ph-Hz

400-3-50 10%Nominal unit current draw** 24 V, via internalCircuits transformer A + B/C


Maximum start-up current standard unit

113

251/125 251/167 334/ 125 334/ 167 535/371 535/426 645/371 645/426

kW A

129/167/-

142/- Circuits 161/A + B/C 174/-

193/-

206/-

225/- 353258/-375 193/97 A 348

193/129 258/97481 258/129 426 448 502

input of the compressor(s) operating conditions. Values given on the334/167 unit name plate. 185/-* Power 209/226/250/- + fan(s) 268/- at maximum 292/- unit 334/250/125 250/167 334/125

** Nominal unit current draw at nominal conditions: evaporator entering/leaving water temperature 12C/7C, outdoor air temperature 35C. Current values at 400 V. Maximum instantaneous starting current at 400 V nominal voltage and operating limit values with compressor in across-the-line start (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).

Note: Units 30RB 602-802 have two electrical connection points (s) at maximum unit operating conditions. Values given on the unit name plate. onditions: evaporator entering/leaving water temperature 12C/7C, outdoor air temperature 35C. Current values at 400 V. t at 400 V nominal voltage and with compressor in across-the-line start (maximum operating current of the smallest compressor(s) + fan current + locked .
connection points.

426/-

448/-

481/-

502/-

535/-

557/-

590/-

645/-

535/371 535/426 645/371 645/426

Hydronic module Single and dual low-/high-pressure pump Shaft power Power input* kW kW

182 2/4

202 2/4

232 2/4

262 2/4

302 3/6 3.6/6.4

342 3/6

372 4/8 4.6/8.5

402 4/8 4.6/8.5

432 4/8 4.6/8.5

462 6/11 6.3/12.2

522 6/11 6.3/12.2

602 -

672 -

732 -

802 -

262

302

342

372

mp kW kW A
given for guidance only.

2.7/4.7 4.7/8.2

402

2.7/4.7

2.7/4.7 4.7/8.2

432

2.7/4.7 4.7/8.2

462

522

3.6/6.4

** To obtain the maximum unit operating current draw for a unit with hydronic module add the maximum unit current draw from the electrical data table in section 5 to the pump current draw** in the table above. a unit with hydronic module add the maximum unit power input from the electrical data table in section 5 to the pump power input* in the table above. urrent draw for a unit with hydronic module add the maximum unit current draw from the for electrical data only. table in section 5 to the pump current draw** in Note: The water pump power input values are given guidance

2/4 3/6 3/6 4/8 4/8 4/8 6/11 6/11 4.6/8.5 4.6/8.5 6.3/12.2 6.3/12.2 2.7/4.7 3.6/6.4 3.6/6.4 4.6/8.5 * To obtain the maximum power input for a unit with hydronic module add the maximum unit power input from the electrical data table in section 5 to the pump power input* in the table 4.7/8.2 6.4/11.2 6.4/11.2 8.2/15.4 8.2/15.4 8.2/15.4 11.2/21.2 11.2/21.2 above.

Maximum current draw at 400 V**

4.7/8.2

6.4/11.2 6.4/11.2 8.2/15.4 8.2/15.4 8.2/15.4 11.2/21.2 11.2/21.2

Dimensions, mm
Dimensions mm Length
Notes: 1. Evaporator t =Height 5K 2. With the evaporator frost protection option the evaporator is protected against frost down to -20C. Operating range with winter operation option and evaporator frost protection option, if the circuit does not contain any anti-freeze solution.

182

202 2253

232 2253 2297

262 2253

302 2253

342 2253 2297

372 2253

402 3604 2253 2297

432 4798 2253 2297

462 4798 2253 2297

522 4798 2253 2297

602 5992 2253 2297

672 5992 2253 2297

732 7186 2253 2297

802 7186 2253 2297

30RB A

262 mm 2410 mm
mm

432-522 2410 302-402 2410 2410 2410


2253 2297

602-672 3604 3604732-802 3604 5992 2297 7186 2297

Width

3604 2297

4798 2297

perature C A

2297

3 225

121

30R 182-802

Electrical data

30RQ - AIR TO WATER HEAT PUMPS

CONTROLS

fEaTUREs
Eleven sizes with nominal cooling capacities from 174 to 465 kW and nominal heating capacities from 189 to 548 kW. State-of-the-art Aquasnap Puron heat pumps featuring the latest technological innovations and operating on the ozone-friendly refrigerant R410A. Integrated hydronic module with water pump and expansion tank. Low-noise scroll compressors with low vibration levels. V-shaped air heat exchanger coils, allowing quieter air flow across the coil. Low-noise 4th generation Flying Bird fans, now even quieter. Rigid fan installation prevents start-up noise. Simplified electrical connections. Fast commissioning, as all units are systematically run tested before shipment. Economical operation with increased energy efficiency at part load and dynamic superheat management. Leak-tight refrigerant circuit and reduced maintenance costs. Auto-adaptive control algorithm and automatic compressor unloading for increased reliability. Exceptional endurance tests.

Pro-Dialog Plus operator interface.

OpTIoNs aND accEssoRIEs


Euro Pack: enclosure panels, water heat exchanger frost protection, main disconnect switch and low noise level (option). Air heat exchanger with pretreated fins (option). Suction valve (option). Enclosure panels and grilles (option). Water heat exchanger and hydronic module with aluminium jacket (option). High or low-pressure single or dual-pump hydronic modules (option). Water heat exchanger frost protection (option). Low noise level (option). Twinning (option). Main disconnect switch with or without fuse (option). JBus, BacNet or LON gateway (option). Winter operation in cooling mode (option). Coil defrost resistance heaters (option). Energy Management module EMM (option/accessory). Connection sleeve (accessory). Scrolling Marquee Interface (accessory). Power cable connection side extension (accessory).
Notes: 1.Water heat exchanger Dt = 5 K 2.With the water heat exchanger frost protection option the water heat exchanger is protected against frost down to -200C.

122

WITH INTEGRATED HYDRONIC MODULE

Physical data
30RQ Nominal cooling capacity* Total power input, cooling mode Nominal heating capacity** Total power inut, heating mode Operating weight*** Standard unit with Euro Pack option Refrigerant Compressors Control
262 kW kW kW kW kg kg kg 249 100 276 96 2619 2864 2429 302

182 kW kW kW kW kg kg 174 60 189 63 2340 2160

202 189 72 212 74 2406 2236

232 219 76 229 77 2432 2242

262 254 99 280 96 2620 2429

302 278 105 301 110 3276 3045

342 307 124 333 119 3471 3241

372 331 126 364 128 3578 3328

402 366 146 405 148 3718 3458

432 389 150 442 159 4318 4028

462 430 165 502 180 4484 4194

522 465 192 548 201 4694 4384

TEGRATED HYDRONIC MODULE Standard unit without option****

R-410 Hermetic scroll, 48.3 r/s Pro-Dialog Plus Grooved copper tubes and aluminium fins
372 326 128 402 366 146 407 148 3718 432 389 150 445 158 4328 462 430 165 505 180 4530 522

Air heat exchangers Fans


342

275 307 Quantity 106 124

302 335 366 110 Water Heat 119 Exchanger 128 3285 Water pump 3481

Total air flow

l/s

18056 552

465 192 201

Axial FLYING BIRD 4 with rotating shroud 4 18056 4 4 5 5 6 6 27083 7 31597 8 36111 8 36111 18056 18056 22569 22569 27083 Direct expansion, two-circuits, shell-and-tube Low or high pressure, single or twinned dual pump (as required)

Hydronic module (option)


3544

4704

3590 3786 3889 4063 4673 4945 5119 * Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12C/7C, outside air temperature 35C water heat exchanger fouling factor 0.18 x 104 (mK)/W 3045 3241 3284 3458 4028 4210 4384 ** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 40C/45C, outside air temperature 7C, 87% rh, air heat exchanger fouling factor 0.18 x 104 (mK)/W R410A *** Weights are for guidance only. To find out the unit refrigerant charge, please refer to the unit name plate. **** r/s Standard unit: Base unit without Euro Pack Option and hydronic module. Hermetic scroll, 48.3 Pro-Dialog Grooved copper tubes and aluminium fins Axial FLYING BIRD 4 with rotating shroud 30RQ (without hydronic module) 4 5 5 6 6 Power circuit 18056 22569 22569 27083 27083 7 31597 8 36111

Electrical data

182

l/s

8 36111

202

232

262

302

342

372

402

432

462

522

Nominal power supply Direct expansion, two-circuits, shell-and-tube


Low or high pressure, single unit or twinned dual pump (as required) Maximum power input**

V-ph-Hz

400-3-50 24 V, via internal transformer 98 129 102 135 127 167 140 185 159 209 166 226 191 251 204 269 229 293 255 334

Control circuit supply

mperature of 120C/70C, an outside air temperature of 350C, and a water heat exchanger fouling factor 0.000018 m2 K/W Circuits A+B kW 85 mperature of 400C/450C, an outside air temperature of 70C, and 87% rh ant charge, please refer to the unit name plate. unit current draw* Nominal

Circuits A + B Maximum start-up current


262 V-ph-Hz 302

113

Standard unit Circuits A + B


342

372

402

432

462

353

522

375

348

426

448

481

492

536

558

601

645

400-3-50 10%

kW A A

* Power input of the compressor(s) + fan(s) at maximum unit operating conditions. Values given on the unit name plate. 24 V, via internal ** transformer Nominal unit current draw at nominal conditions: water heat exchanger entering/leaving water temperature 12C/7C, outdoor air temperature 35C. The current values are given at 400 V nominal voltage. starting 400 V nominal and operating limit values with compressor in across-the-line start (maximum operating current of the smallest 127 140 Maximum 159 instantaneous 166 191 current at 204 229 voltage255 compressor(s) + fan current + locked rotor current of the largest compressor).
167 426 185 448 209 219 492 251 536 269 558 302 601 334

Hydronic module
481

182

nit operating conditions saturated suction temperature 100C, saturated condensing temperature 650C at 400 V nominal voltage (values

Single and dual low-/high-pressure pump Shaft power

645

202 2,2/4

232 2,2/4 2,7/4,7 4,7/8,2

262 2,2/4 2,7/4,7 4,7/8,2

302 3/6 3,6/6,4 6,4/11,2

342 3/6 3,6/6,4 6,4/11,2

372 4/8 4,6/8,5 8,2/15,4

402 4/8 4,6/8,5 8,2/15,4

432 4/8 4,6/8,5 8,2/15,4

462 6/11 6,3/12,2 11,2/21,2

522 6/11 6,3/12,2 11,2/21,2

2,2/4

mperature of 120C/70C and an outside air temperature of 350C Power input* ting current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).

2,7/4,7 4,7/8,2

2,7/4,7 4,7/8,2

Maximum current draw at 400 V**

262 kW kW kW A 2.2/4.0 2.7/4.7 4.5/7.6 4.7/8.2

302

342 372 402 432 462 522 * To obtain the maximum power input for a unit with hydronic module add the maximum unit power input from the electrical data table in section 5 to the pump power input* in the table above. ** To obtain the maximum draw for a unit with hydronic module add the maximum unit current draw from the electrical data table in section 5 to the pump current 3.0/5.5 3.0/5.5 4.0/7.5unit operating 4.0/7.5 current 4.9/7.5 6/11 6/11 in the table above. 3.6/6.4draw** 3.6/6.4 4.6/8.5 4.6/8.5 4.6/8.5 6.3/12.2 6.3/12.2

6.0/10.3 6.0/10.3 7.6/13.9 7.6/13.9 7.6/13.9 10.3/19.5 10.3/19.5 Note: The water pump power input values are given for 11.2/21.2 guidance only. 6.4/11.2 6.4/11.2 8.2/15.4 8.2/15.4 8.2/15.4 11.2/21.2

e only. nic module add the maximum unit power input from the electrical data table in section 5 to the pump power input* in182 the table above.. Dimensions mm 202 unit with hydronic module add the maximum unit current draw from the electrical data table in section 5 to the pump current draw** in

232 2410 2253 2297

262 2410 2253 2297

302 3604 2253 2297

342 3604 2253 2297

372 3604 2253 2297

402 3604 2253 2297

432 4798 2253 2297

462 4798 2253 2297

522 4798 2253 2297

Length Width Height

mm

2410

2410

mm mm

2253 2297

2253 2297

22

22

53

2297

123

30RQ 182-522

30RY/30RYH - AIR COOLED UNITS

CONTROLS Ductable liQuid chillers with integrated hydronic module. The 30RY chillers and RYH air-to-water heat pumps are designed for indoor installation and incorporate the latest technological innovations for optimised comfort. FEaTUREs ACCESSORIES/OPTIONS
Air heat exchanger anti-corrosion pretreatment for light marine applications. Air heat exchanger post-assembly corrosion treatment for heavy-duty rural, urban and industrial applications. Electronic starter for reduced start-up current. Low-temperature unit for leaving glycol temperatures from 0C to -10C (30RY). Unit without hydronic module. Hydronic module with dual pump (040080). Unit support with condensate recovery pan. Outside installation. Communications board with open JBus protocol. Units incorporate the latest technological innovations such as the scroll compressor and the auto-adaptive microprocessor control.

PRO-DIALOG PLUS operator interface.

Quiet axial fan with available pressure does not require any specific adjustment at installation. Hinged control box door and removable panels permit easy access to all components. The welded plate heat exchanger offers high performances and low waterside pressure drops. Integrated hydronic module for fast installation, incorporating all components necessary for the operation of the system. Quiet and vibration-free scroll compressors, known for their durability and reliability.

124

CHILLERS AND HEAT PUMPS 30RY/RYH - AIR-COOLED UNITS


CHILLERS AND HEAT PUMPS
Physical data
30RY/30RYH Nominal cooling capacity 30RY* Nominal cooling capacity 30RYH* Nominal heating capacity 30RYH** kW kW kW 017 18.6 17.8 18.3 386/361 410/385 021 23.1 22.4 22.1 416/391 440/415 026 25.8 24.1 25.6 436/411 460/435 033 31.7 31.3 34.5 451/426 475/450 040 39.4 37.8 37.0 510/590 486 550/630 526 050 50.0 44.7 48.3 572/652 548 612/692 588 060 58.0 56.0 55.0 587/667 563 627/707 603 070 67.0 65.0 62.0 638/718 614 688/768 664 080 79.0 76.0 78.0 675/752 649 736/813 710

CHILLERS AND HEAT PUMPS 30RY/RYH

Operating weight 30RY with hydronic module, single/dual pump 30RY without hydronic module

30RYH with hydronic module, single/dualpump 30RYH without hydronic module Refrigerant charge Compressors Control type

R-407C

Hermetic scroll compressors, 48.3 r/s (one for sizes 017-040, two for sizes 050-080) Grooved copper tubes, aluminium fins Pro-Dialog Plus

Air heat exchanger

Fan Available static pressure Total air flow (high speed) Water heat exchanger Hydronic module Pump (centrifugal)
* **

Pa l/s

100 1940

100 1940

100 1940

Direct-expansion welded plate heat exchanger

One, axial with available pressure 100 150 150 2500 3890 3890

150 4720

150 5830

150 5830

Nominal conditions: water heat exchanger entering/leaving temperature 12C/7C, outdoor air temperature 35C. Nominal conditions: air heat exchanger entering/leaving temperature 40C/45C, outdoor air dry bulb temperature 7C.

Electrical data
30RY/30RYH (without hydronic module) Power circuit Nominal power supply Voltage range Control circuit supply Maximum unit power input* Nominal unit current draw** Maximum start-up current Standard unit
*

017 V-ph-Hz V kW A A 9.8 13.1 87.8

021

026

033

040 400-3-50 360-440 21.0 28.8

050

060

070

080

12.1 16.2 131.8

The control circuit is supplied via the unit-mounted transformer 13.8 18.6 18.0 23.3 25.3 35.6 32.3 45.7

38.2 52.1 181.2

42.9 59.4 195.5

131.8

147.4

159.3

151.8

173.5

Power input of the compressor(s) + fan at maximum unit operating conditions: entering/leaving water temperature = 15C/10C, maximum condensing temperature of 67.8C and 400 V nominal voltage (values given on the unit name plate). ** Nominal unit current draw at the following conditions: evaporator entering/leaving water temperature 12C/7C, outdoor air temperature 35C. The current values are given at 400 V nominal voltage. *** Maximum instantaneous starting current at 400 V nominal voltage and with compressor in across-the-line-start (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).

Hydronic module 30RY/30RYH Single pump/dual pump Power input* Maximum current draw at 400 V**

kW kW A

017 0.75/0.75/2.0/-

021 0.75/0.75/2.0/-

026 0.75/0.75/2.0/-

033 0.75/0.75/2.0/-

040 0.75/2.2 1.1/2.7 2.1/4.7

050 0.75/2.2 1.1/2.7 2.1/4.7

060 0.75/2.2 1.1/2.7 2.1/4.7

070 0.75/2.2 1.1/2.7 2.1/4.7

080 1.1/2.2 1.4/2.7 3.1/4.7

Note: The water pump power input values are given for guidance only. * To obtain the maximum power input for a unit with hydronic module add the maximum unit power input from the top table to the pump power input (*) from the table above. ** To obtain the maximum unit operating current draw for a unit with hydronic module add the maximum unit current draw from the top table to the pump current draw from the table above.

Dimensions/clearances, mm
Leave 1000 mm clearance in front of the unit and at the right-hand side.

Operating limits
Cooling mode Heating mode

Entering air temperature

1351 (017-033) 1372 (040-080)

205 209 8 (01 7 (0 7-03 40- 3) 080 )

Leaving water temperature Notes: Leaving water temperature 1. Water heat exchanger t = 5 K. 2. 30RYH 017-033: Install the unit in a location that is frost-free. 30RYH 040-080: The evaporator and the hydronic module are protected against frost down to -20C. 3. Maximum air entering temperature at nominal static pressure of the fan.
) -033 ) (017 962 040-080 ( 1128

Operating range with required anti-freeze solution and special Pro-Dialog control configuration.

Entering air temperature

125

30RY/30RYH

Single multicell pump, 48.3 r/s

Single monocell pump, 48.3 r/s

30RW/30RWA - WATER COOLED UNITS

CONTROLS The new generation of 30RW/30RWA AQuasnap liQuid chillers features the latest technological innovations to ensure reliable and economical operation under any climate conditions. FEATURES ACCESSORIES/OPTIONS
Chiller with a dual evaporator and condenser water pump. Chiller without condenser 30RWA. Chiller without hydronic module. Heat pump (hot or cold water control). Low leaving-water temperature down to -100C. Electronic starter for reduced start-up current. CCN Clock Board RS485 communications and time schedule board. Communication board for the Aquasmart system. Integrated hydronic evaporator and condenser modules, simplifying the installation. Intelligent control of condenser water pump speed to ensure reliable and economical operation. Variable-speed condenser water pump automatically adjusts the water flow rate to maintain ideal condensing conditions. High performance plate heat exchangers maximise the thermodynamic properties of the refrigerant.

PRO-DIALOG PLUS operator interface.

Space-saving design.

No plant room required, the unit can be installed in a public open place, if local regulations permit. Integrated hydronic evaporator and condenser modules, simplifying the installation.

126

30XA engl.qxd

4/22/09

4:51 PM

Page 2

WATER-COOLED CHILLERS 30XA


AIR-COOLED LIQUID CHILLERS
Physical data*
30XA 252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1202 1302 1352 1402 1502 1702 kW kW kg kg
268 274 293 300 320 326 382 393 437 451 492 508 605 616 653 677 706 726 764 792 802 838 869 899 952 1116 1216 1297 1382 1426 1478 1605 1000 1147 1247 1354 1442 1468 1523 1675

AIR-COOLED LIQUID CHILLERS 30XA

Nominal cooling capacity** Standard low-noise unit High-efficiency/high-temperature option Operating weight*** Standard high-efficiency Unit with Cu/Al coil option Refrigerant Compressors Control Condensers Fans Quantity, standard unit/unit with Cu/Al coil Evaporator

3840 3880 3920 4780 4850 5330 6260 6410 6710 7010 7560 7860 8440 10440 10880 11260 11620 12011 12155 14279 4160 4190 4710 5790 5260 5830 6870 7030 7820 8140 8260 9010 9260 11470 11890 12250 12640 13207 13365 15689

R134a 06T semi-hermetic screw compressors, 50 r/s PRO-DIALOG, electronic expansion valve (EXV) Aluminium micro-channel heat exchangers Axial Flying Bird IV fans with rotating shroud
6/6 6/6 6/7 8/8 8/8 9/9 11/11 12/12 12/13 12/13 14/14 14/15 16/16 19/19 20/20 20/20 20/20 24/24 24/24 28/28

Flooded multi-pipe type

* Preliminary data this product will be available during 2006. Please check availability with your Carrier representative. ** Based on an evaporator entering/leaving water temperature of 12C/7C, an outdoor air temperature of 35C and an evaporator fouling factor = 0.000018 m2 K/W *** Weights are guidelines only. Note: Sizes 30XA 1402-1702 are delivered as two modules for field assembly

Electrical data
30XA Power circuit Nominal power supply Control circuit V-ph-Hz 252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 400-3-50 10% 24 V via internal transformer 1202 1302 1352 1402 1502 1702

Maximum start-up current, circuits A + B/C + D** Standard low-noise unit High-efficiency/temperature option Maximum power input, circuits A + B/C + D Standard low-noise unit High-efficiency/temperature option Maximum unit current draw, circuits A + B/C + D*** Standard low-noise unit High-efficiency/temperature option

A A

262/- 262/- 284/- 395/- 502/- 502/- 571/- 597/- 770/- 795/- 796/- 880/- 932/- 571/587 770/587 795/587 878/587 880/587 932/587 796/796 262/- 262/- 283/- 400/- 507/- 507/- 579/- 608/- 778/- 803/- 807/- 892/- 945/- 579/587 778/587 803/587 889/587 892/587 945/587 807/807

kW kW

121/- 131/- 141/- 165/- 185/- 204/- 247/- 267/- 293/- 312/- 343/- 359/- 420/- 247/210 293/210 342/210 388/209 390/210 420/210 343/343 126/- 136/- 147/- 172/- 192/- 212/- 257/- 278/- 304/- 323/- 356/- 372/- 435/- 257/217 304/217 353/217 400/216 405/217 435/217 356/356

A A

198/- 215/- 233/- 270/- 303/- 335/- 404/- 436/- 492/- 522/- 572/- 611/- 707/- 404/354 492/354 568/354 655/352 661/354 707/354 572/572 208/- 226/- 243/- 284/- 316/- 350/- 423/- 457/- 512/- 542/- 596/- 635/- 734/- 423/367 512/367 588/367 678/364 688/367 734/367 596/596

* Preliminary data this product will be available during 2006. Please check availability with your Carrier representative. ** Power input of the compressors and fan(s) at maximum unit operating conditions *** Maximum unit operating current at maximum unit operating conditions and nominal voltage. Note: Sizes 30XA 1102-1702 have two power supply connections (circuits A + B and circuits C + D)

Operating limits
Evaporator water temperature Water entering temperature at start-up Water entering temperature during operation Water leaving temperature during operation C Minimum 6.8 3.3 Maximum 45 21 15

Dimensions, mm
Standard (MCHX heat exchanger) 30XA 252-352 A 3604 402-452 + 4798 502 5992 602-802 7186 852-902 + 8380 1002 + 9574 11021352 11962

Note: If the temperature is below 4C, a glycol/water solution or frost protection option must be used.

30XA A

1402-1502 1402-1502 module 1/2 module 2/2 9574 4798

1702 1702 module 1/2 module 2/2 8380 8380

Condenser air temperature Operation Standard unit With winter operation option (No. 28) Operation High efficiency/temperature version

Minimum -10 -20 -

Maximum 55* 55* 55**

A
2253

112

2297

Note: If the air temperature is below 3C, a glycol/water solution or the frost protection option must be used. * Full or part-load operation, depending on the model ** Part-load operation

127

30RW/30RWA

30 - AIR-COOLED LIQUID CHILLERS

FEaTUREs
Twenty sizes with nominal cooling capacities from 268 to 1673 kW.

coNTRoLs

The ideal solution for industrial and commercial applications with optimal performances and maximum quality. Available in two versions: one with extremely low noise levels and superior energy efficiency; the other with unequalled energy efficiency for minimised operating costs. Twin-rotor screw compressors with high-efficiency motor and a variable capacity valve for exact matching of the cooling capacity to the load.

Touch-screen Pro-Dialog operator interface.

All aluminium micro-channel heat exchanger (MCHX) with increased corrosion resistance and higher efficiency than a copper/aluminium coil. Use of R134a refrigerant with zero ozone depletion potential - the microchannel heat exchangers reduce the refrigerant charge by 30%. Low-noise 4th generation Flying Bird fans made of composite material. Touch-screen Pro-Dialog control system. Flooded multi-pipe evaporator. Economizer system with electronic expansion device for increased cooling capacity. V-shape condenser coils allow quieter air flow across the coil. Simplified electrical connections. Units are run-tested before shipment and include a quick-test function for fast commissioning. Leak-tight refrigerant circuit. Comprehensive endurance tests. Aquaforce offers multiple remote control, monitoring and diagnostic possibilities.

OpTIoNs/ACCESSOIRES
Grilles. Electronic starter. Winter operation. Suction valve. High energy efficiency, high ambient temperature. Unit without enclosure. Energy Management module EMM. One or three-pass evaporator. Reversed water connections. Low water temperature version. Low or high-pressure, single or dual-pump hydronic module. Traditional coils. Corrosion protection, traditional coils. Evaporator and hydronic module frost protection. IP54 control box. High-temperature version (Middle East). JBus/BacNet or LON gateway.

128

30XA engl.qxd

4/22/09

4:51 PM

Page 2

30XA 30XA

AIR-COOLED LIQUID CHILLERS AIR-COOLED LIQUID CHILLERS


Physical data* Physical data*
30XA

252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1202 1302 1352 1402 1502 1702
252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1202 1302 1352 1402 1502 1702
268 293 320 382 437 492 605 653 706 764 802 869 952 1116 1216 1297 1382 1426 1478 1605 274 268 300 293 326 320 393 382 451 437 508 492 616 605 677 653 726 706 792 764 838 802 899 869 1000 952 1147 1116 1247 1216 1354 1297 1442 1382 1468 1426 1523 1478 1675 1605 274 300 326 393 451 508 616 677 726 792 838 899 1000 1147 1247 1354 1442 1468 1523 1675 3840 3880 3920 4780 4850 5330 6260 6410 6710 7010 7560 7860 8440 10440 10880 11260 11620 12011 12155 14279 4160 3880 4710 3920 5790 4780 5260 4850 5830 5330 6870 6260 7030 6410 7820 6710 8140 7010 8260 7560 9010 7860 9260 8440 11470 1044011890 1088012250 1126012640 1162013207 1201113365 1215515689 14279 3840 4190 4160 4190 4710 5790 5260 5830 6870 7030 7820 8140 8260 9010 9260 11470 11890 12250 12640 13207 13365 15689 R134a

AIR-COOLED LIQUID CHILLERS 30XA 30XA AIR-COOLED LIQUID CHILLERS

Nominal cooling capacity** 30XA Standard unit kW Nominal low-noise cooling capacity** High-efficiency/high-temperature option kW Standard low-noise unit kW option kW High-efficiency/high-temperature Operating weight*** high-efficiency kg Standard weight*** Operating with Cu/Al coil option kg Unit high-efficiency kg Standard Unit with Cu/Al coil option kg Refrigerant
Refrigerant Compressors Compressors Control Control Condensers Condensers Fans Fans Quantity, standard unit/unit with Cu/Al coil Quantity, standard unit/unit with Cu/Al coil Evaporator

R134a 06T semi-hermetic screw compressors, 50 r/s 06T semi-hermetic screw compressors, r/s PRO-DIALOG, electronic expansion valve 50 (EXV) PRO-DIALOG, electronic expansion valve (EXV) Aluminium micro-channel heat exchangers Axial 6/6 Flying6/7 Bird IV fans8/8 with rotating shroud 6/6 8/8 9/9 11/11 12/12 12/13 12/13 14/14 14/15 16/16 19/19 20/20 20/20 20/20 24/24 24/24 28/28 6/6 6/6 6/7 8/8 8/8 9/9 11/11 12/12 12/13 12/13 14/14 14/15 16/16 19/19 20/20 20/20 20/20 24/24 24/24 28/28 Aluminium micro-channel heat exchangers Axial Flying Bird IV fans with rotating shroud

Flooded type *Evaporator Preliminary data this product will be available during 2006.multi-pipe Please check availability with your Carrier representative. ** on an evaporator entering/leaving temperature of 12C/7C, outdoor air temperature ofCarrier 35C and an evaporator fouling factor = 0.000018 m2 K/W * Based Preliminary data this product will bewater available during 2006. Please an check availability with your representative. *** are guidelines only. ** Weights Based on an evaporator entering/leaving water temperature of 12C/7C, an outdoor air temperature of 35C and an evaporator fouling factor = 0.000018 m2 K/W *** Weights are guidelines only. Note: Sizes 30XA 1402-1702 are delivered as two modules for field assembly Note: Sizes 30XA 1402-1702 are delivered as two modules for field assembly

Flooded multi-pipe type

Electrical data Electrical data


30XA 30XA Power circuit Power circuit power supply V-ph-Hz Nominal Nominal power supply V-ph-Hz Control circuit Control circuit Maximum start-up current, Maximum start-up current, circuits A + B/C + D** circuits A + B/C + D** A Standard low-noise unit A Standard low-noise unit High-efficiency/temperature option A A High-efficiency/temperature option Maximum power input, Maximum power input, circuits A + B/C + D circuits A + B/C + D Standard low-noise unit kW Standard low-noise unit kW High-efficiency/temperature option kW High-efficiency/temperature option kW Maximum Maximumunit unitcurrent currentdraw, draw, circuits circuitsAA++B/C B/C++D*** D*** Standard low-noise unit AA Standard low-noise unit High-efficiency/temperature AA High-efficiency/temperatureoption option 252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1202 1302 1352 1402 1502 1702 252 302 352 402 452 502 602 702 752 802 852 902 1002 1102 1202 1302 1352 1402 1502 1702 400-3-50 10% 400-3-50 10% 24 V via internal transformer 24 V via internal transformer
262/- 262/- 284/- 395/- 502/- 502/- 571/- 597/- 770/- 795/- 796/- 880/- 932/- 571/587 770/587 795/587 878/587 880/587 932/587 796/796 262/- 262/- 284/- 395/- 502/- 502/- 571/- 597/- 770/- 795/- 796/- 880/- 932/- 571/587 770/587 795/587 878/587 880/587 932/587 796/796 262/- 262/- 283/- 400/- 507/- 507/- 579/- 608/- 778/- 803/- 807/- 892/- 945/- 579/587 778/587 803/587 889/587 892/587 945/587 807/807 262/- 262/- 283/- 400/- 507/- 507/- 579/- 608/- 778/- 803/- 807/- 892/- 945/- 579/587 778/587 803/587 889/587 892/587 945/587 807/807

121/121/126/126/-

131/131/136/136/-

141/141/147/147/-

165/165/172/172/-

185/- 204/- 247/- 267/- 293/- 312/- 343/- 359/185/- 204/- 247/- 267/- 293/- 312/- 343/- 359/192/- 212/- 257/- 278/- 304/- 323/- 356/- 372/192/- 212/- 257/- 278/- 304/- 323/- 356/- 372/-

420/420/435/435/-

247/210 293/210 342/210 388/209 390/210 420/210 343/343 247/210 293/210 342/210 388/209 390/210 420/210 343/343 257/217 304/217 353/217 400/216 405/217 435/217 356/356 257/217 304/217 353/217 400/216 405/217 435/217 356/356

198/335/-404/404/-436/436/-492/492/-522/522/-572/572/-611/611/- 707/707/- 404/354 404/354 492/354 492/354 568/354 568/354 655/352 655/352 661/354 661/354 707/354 707/354 572/572 572/572 270/- 303/303/-335/233/- 270/198/- 215/215/- 233/208/208/- 226/226/- 243/243/- 284/284/- 316/316/-350/350/-423/423/-457/457/-512/512/-542/542/-596/596/-635/635/- 734/734/- 423/367 423/367 512/367 512/367 588/367 588/367 678/364 678/364 688/367 688/367 734/367 734/367 596/596 596/596 ** Preliminary Preliminarydata datathis thisproduct productwill willbe beavailable availableduring during2006. 2006.Please Pleasecheck checkavailability availabilitywith withyour yourCarrier Carrierrepresentative. representative. ** ** Power Powerinput inputof ofthe thecompressors compressorsand andfan(s) fan(s)at atmaximum maximumunit unitoperating operatingconditions conditions *** *** Maximum Maximumunit unitoperating operatingcurrent currentat atmaximum maximumunit unitoperating operatingconditions conditionsand andnominal nominalvoltage. voltage.
Note: D) Note:Sizes Sizes30XA 30XA1102-1702 1102-1702have havetwo twopower powersupply supplyconnections connections(circuits (circuitsAA++BBand andcircuits circuitsCC++D)

Operating Operatinglimits limits


Evaporator Evaporatorwater watertemperature temperature Water Waterentering enteringtemperature temperatureat atstart-up start-up Water Waterentering enteringtemperature temperatureduring duringoperation operation leavingtemperature temperatureduring duringoperation operation Waterleaving Water C C Minimum Minimum -6.8 6.8 3.3 3.3 Maximum Maximum 45 45 21 21 15 15

Dimensions, Dimensions,mm mm
Standard (MCHX heat exchanger) 402-452 + 30XA 252-352 402-452 + 502 30XA 252-352 352 Cu/Al 502

602-802 602-802 7186 7186

852-902 + 852-902 + 752-802 Cu/Al 8380 8380

1002 + 1002 + 902 Cu/Al 9574 9574

A A

3604 3604

4798 4798

5992 5992

110211021352 1352 11962 11962

Note:IfIfthe thetemperature temperatureisisbelow below4C, 4C,aaglycol/water glycol/watersolution solutionor orfrost frostprotection protectionoption optionmust must Note: beused. used. be

1402-1502 1402-1502 30XA 1402-1502 1402-1502 30XAmodule 1/2 module 2/2 module 1/2 module 2/2 A A 9574 9574 4798 4798

1702 1702 1702 1702 module 1/2 module 2/2 module 1/2 module 2/2 8380 8380 8380 8380

Condenserair airtemperature temperature Condenser Operation Operation Standardunit unit Standard Withwinter winteroperation operationoption option(No. (No.28) 28) With Operation Operation Highefficiency/temperature efficiency/temperatureversion version High

C Minimum Minimum C -10 -10 -20 -20

Maximum Maximum 55* 55* 55* 55* 55** 55**

--

A A
2253 2253

112 112

2297 2297

Note:IfIfthe theair airtemperature temperatureisisbelow below3C, 3C,aaglycol/water glycol/watersolution solutionor orthe thefrost frostprotection protectionoption option Note: mustbe beused. used. must * Full or part-load operation, depending on the model * Full or part-load operation, depending on the model ** Part-load Part-loadoperation operation **

129

30XA

30W- 30XWH - WATER-COOLED

FEaTUREs coNTRoLs
16 sizes of Standard range with nominal cooling capacity from 476 to 1704 kW. 11 sizes of Premium range with nominal cooling capacity from 509 to 1748 kW. Premium solution for industrial and commercial applications where optimal performance and maximum quality are required. Superior operating economy : energy class (Eurovent) EER up to 6.18 kW/kW (30XW-P) ESEER up to 8.08 kW/kW (30XW-P) (EUROVENT). Touch-screen Pro-Dialog operator interface. Efficiency: More affordable to operate and environmentally responsible, contributing to the reduction of building energy consumption and CO emissions . Flexibility: It can satisfy the different requirements of every market segment, heating, air conditioning or industrial. Pro-Dialog operator interface with touch-screen. Optimised Heat Exchanger Design. Flexible and reliable compression. New generation 06T screw compressor. Low operating sound levels : Silencers on the discharge line Silencers on the economizer return line Acoustic insulation on the components.

OpTIoNs/ACCESSOIRES
Low/very low temperature glycol solution. Control for low condensing temperature systems . Service valve set. High condensing temperature. Energy Management Module (EMM). JBus/BacNet or LON gateway.

130

LIQUID CHILLERS

Physical data
30XW/XWH Standard Units Nominal cooling capacity* Heating capacity** Operating Weight Compressors Refrigerant charge Capacity control Evaporator Water connections Condensers kg kW kW kW kW kg 452 476 506 2810 552 535 580 2850 602 548 616 2890 652 658 702 721 802 780 852 839 1002 1016 1081 1052 1060 1127 1152 1155 1284 1252 1232 1352 1345 1452 1475 1552 1566 1652 1638 1702 1704 -

5550 5590 6100 06T semi-hermetic screw compressors, 50 r/s R-134A PRO-DIALOG, electronic expansion valve (EXV)

Flooded multi-pipe type with internally finned copper tubes Victaulic, 3/8 NPT drain and vent, maximum water-side operating pressure 1000 kPa Multi-pipe type with internally finned copper tubes

* Eurovent conditions, cooling mode: evaporator entering/leaving water temperature = 12C/7C, condenser entering leaving water temperature = 30C/35C. ** Eurovent conditions, heating mode: condenser entering/leaving water temperature = 40C/45C, evaporator entering water temperature - 10C with the same flow rate as for the Eurovent cooling mode conditions. For the unit refrigerant charge refer to the unit nameplate.

Electrical data
30XW/XWH Standard Units Power circuit Nominal power supply Control circuit supply Maximum start-up current* Circuit** Maximum power input Circuit Maximum current drawn (Un) Circuit 217/242/242/242/217 242/242 242/242 * Evaporator entering/leaving water temperature 12C/7C, condenser entering leaving water temperature = 30C/35C. ** Eurovent conditions, heating mode: condenser entering/leaving water temperature = 40C/45C, evaporator entering water temperature - 10C with the same flow rate as for the Eurovent cooling mode conditions. For the unit refrigerant charge refer to the unit nameplate.

452 V-ph-Hz

552

602

652

702

802

852

1002

1052

1152

1252

1352

1452

1552

1652

1702

400-3-5010% 24 V via the built-in transformer

A kW

414/1341/-

414/151/-

414/151/-

414/414 414/414 414/414 151/134 151/151 151/151

Dimensions, mm
30XW/XWH Standard Units Length Width Height mm mm mm 452 2742 936 1693 552 2742 936 1693 602 2742 936 1693 652 3048 1038 1900 702 3048 1038 1900 802 3048 1038 1900 852 2768 1050 1950 1002 4085 1036 1870 1052 4085 1036 1870 1152 4093 1036 1926 1252 4796 1153 2109 1352 4796 1153 2100 1452 4796 1153 2100 1552 4809 1153 2100 1652 4872 1683 1798 1702 4872 1683 1798

131

30XW-30XWH

30HXC - WATER-COOLED SCREW

CONTROLS FEaTUREs
Seventeen sizes with nominal cooling capacities from 286 to 1300 kW. PRO-DIALOG Plus control to optimise the efficiency of the refrigerant circuit. Ozone-friendly HFC-134a refrigerant, proven, non-toxic, non-flammable. Equipped with screw compressors for extremely quiet operation and low vibration levels. Control is fully automatic and includes autodiagnostics. Two independent refrigerant circuits. Multiple compressor concept. Series star/delta starter, limiting the start-up current on (30HXC 080-190). Easy installation - compact design, fits through a standard door opening. Supplied as a complete package for easy installation. No extra controls, timers, starters or other items to install. Single power point (30HXC 080 to 190), and one power point per circuit (30HXC 200 to 375). Simple to service: mechanically cleanable evaporator and condenser, twinscrew compressors with minimum routine service. Very low temperature option available for part of the range, allows evaporator leaving water temperatures down to -100C.

PRO-DIALOG Plus operator interface.

Carrier twin-screw compressor.

OpTIoNs/accEssoRIEs
Compressor suction valve (option). Evaporator or condenser with one pass less (option). Evaporator or condenser maximum waterside operating pressure of 21 bar (option). RS485 communications interface with JBus, BacNet, LON protocol (accessory). Electronic compressor starter (30HXC 200375) (option). Electrical protection to IP44C (option). High condensing temperature unit and non-reversible heat pump (option). Reversed evaporator or condenser water inlet/outlet (option). Tropicalized control box (option). Disassembled unit (option). Evaporator or condenser water pump starter (option). Three-way control valve, condensor (option). Heat exchanger water connection kit (accessory). Low evaporator leaving water temperatures < +400C to > -600C (option). Very low evaporator leaving water temperatures < 00C to > -100C (option).

132

COMPRESSOR LIQUID CHILLERS 30HXC


WATER-COOLED SCREW-COMPRESSOR LIQUID CHILLERS
Physical data data Physical
30HXC 30HXC Nominal cooling cooling capacity* capacity* Nominal weight Operating weight Operating kW kW kg kg 080 080 286 286 090 090 312 312 100 100 348 348 110 110 374 374 120 120 412 412 130 130 449 449 140 140 509 509 155 155 541 541 175 175 598 598 190 190 651 651 200 200 699 699 230 230 812 812 260 260 897 897 285 285 985 985 310 345 345 375 375 310 1106 1204 1204 1300 1300 1106

2274 2279 2279 2302 2302 2343 2343 2615 2615 2617 2617 2702 2702 2712 2712 3083 3083 3179 3179 3873 3873 4602 4602 4656 4656 4776 4776 5477 5477 5553 5553 5721 5721 2274 HFC-134a HFC-134a Semi-hermetic, twin-screw twin-screw Semi-hermetic, 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PRO-DIALOG Plus Plus control control PRO-DIALOG 6 6 6 6 6 6 6 6 6 6 1 1 1 1 6 6 1 1 1 1 6 6 1 1 1 1 6 6 1 1 1 1 6 6 1 1 1 1 6 6 2 2 1 1 8 8 2 2 1 1 8 8 2 2 1 1 8 8 2 2 1 1 8 8 2 2 2 2 10 10 2 2 2 2 10 10 2 2 2 2 10 10

WATER-COOLED SCREW-COMPRESSOR LIQUID CHILLERS 30HXC

Refrigerant charge** charge** Refrigerant Compressors Compressors Quantity -- Circuit Circuit A A Quantity Quantity -- Circuit Circuit B B Quantity control Capacity control Capacity No. of of control control steps steps No. Evaporator Evaporator connections Water connections Water Inlet/outlet Inlet/outlet Condenser Condenser connections Water connections Water Inlet/outlet Inlet/outlet
* *

in in

Shell and and tube tube with with internally internally finned finned copper copper tubes tubes Shell Flat flange flange factory-supplied, factory-supplied, to to be be welded welded on on site site Flat 4 4 4 5 5 5 5 5 4 4 4 5 5 5 5 5 Shell and and tube tube with with internally internally finned finned copper copper tubes tubes Shell Flat flange flange factory-supplied, factory-supplied, to to be be welded welded on on site site Flat 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

5 5

5 5

6 6

6 6

6 6

6 6

8 8

8 8

8 8

in in

6 6

6 6

6 6

8 8

8 8

8 8

8 8

8 8

8 8

Standard Eurovent Eurovent conditions: conditions: Evaporator Evaporator entering/leaving entering/leaving water water temperature temperature 12 1200C 30C/3500C. C and and 7 700C. C. Condenser Condenser entering/leaving entering/leaving water water temperature temperature 30C/35 C. Standard Evaporator and and condenser condenser fouling fouling factor factor = = 0.000044 0.000044 m m22 K/W. K/W. Evaporator Not applicable applicable to to high high condensing condensing temperature temperature units units -- please please refer refer to to electronic electronic selection selection catalogue. catalogue. Not

Electrical data data Electrical


30HXC 30HXC Power circuit circuit Power Nominal power power supply supply (Un)* (Un)* Nominal Control circuit circuit supply supply Control Nominal power power input* input* Nominal Nominal current current drawn drawn * * Nominal Maximum starting starting current, current, Maximum standard unit*** unit*** standard Circuit A** A** Circuit Circuit B** B** Circuit kW kW A A A A A A A A 080 080 V-ph-Hz V-ph-Hz 090 090 100 100 110 110 120 120 130 130 140 140 155 155 175 175 190 190 200 200 230 230 260 260 285 285 310 310 345 345 375 375

400-3-50 400-3-50 The control control circuit circuit is is supplied supplied via via the the factory-installed factory-installed transformer transformer The 57 53 101 101 181 181 --62 62 115 115 206 206 --67 67 127 127 223 223 --76 76 143 143 249 249 --80 80 149 149 267 267 --89 89 168 168 298 298 --102 102 190 190 333 333 --112 112 207 207 355 355 --121 121 226 226 382 382 --129 129 234 234 442 442 --140 140 255 255 841 841 712 712 605 605 164 164 294 294 978 978 822 822 715 715 192 192 337 337 195 195 354 354 221 221 399 399 250 250 448 448 263 263 477 477

1027 1200 1200 1129 1129 1184 1184 1373 1373 1027 871 1028 1028 844 844 871 871 1028 1028 871 715 856 856 844 844 871 871 1028 1028 715

Standard Eurovent Eurovent conditions: conditions: Evaporator Evaporator entering/leaving entering/leaving water water temperature temperature 12 1200C 3000C/35 * C and and 7 700C. C. Condenser Condenser entering/leaving entering/leaving water water temperature temperature 30 C/3500C. C. * Standard ** Maximum Maximum unit unit operating operating current current at at maximum maximum unit unit power power input. input. ** Maximum instantaneous instantaneous starting starting current current (maximum (maximum operating operating current current of of the the smallest smallest compressor(s) compressor(s) + + locked locked rotor rotor current current or or reduced reduced starting starting current current of of the the largest largest compressor) compressor) *** Maximum ***

Dimensions/clearances, mm mm Dimensions/clearances,
30HXC 30HXC 080-090-100 080-090-100 110 110 120-130-140-155 120-130-140-155 175-190 175-190 200 200 230-260-285 230-260-285 310-345-375 310-345-375 A A 2558 2558 2565 2565 3275 3275 3275 3275 3903 3903 3924 3924 4533 4533 B B 980 980 980 980 980 980 980 980 1015 1015 1015 1015 1015 1015 C C 1800 1800 1850 1850 1816 1816 1940 1940 1980 1980 2060 2060 2112 2112

Unit operating operating range range at at full full load load Unit
58

50

B
45
0C Condenser water entering temperature, 0

35

30

Notes: Notes: 1. Evaporator Evaporator and and condenser condenser T T= =5 5K K 1. at full full load load with with a a conconFor start-up start-up at 2. For 2. denser water water entering entering temperature temperature below below denser 2000C, C, a a three-way three-way valve valve must must be be used used to to 20 maintain the the correct correct condensing condensing temperature temperature maintain 3. Maximum Maximum condenser condenser water water leaving leaving temperatempera3. 5000C ture 50 C (at (at full full load) load) ture A Standard Standard unit unit operating operating at at full full load. load. A B Standard Standard unit unit operating operating at at reduced reduced load. load. B control C Units Units operating operating with with head head pressure pressure control C with analogue analogue water water control control valve. valve. For For with transient operating operating modes modes (start-up (start-up and and transient part load) load) the the unit unit can can operate operate down down to to a a part condenser entering water temperature of condenser entering water temperature of 1300C. C. 13 Additional operating operating range range for for high high Additional condensing temperature temperature units units and and condensing non-reversible heat heat pumps. pumps. non-reversible
13 15 20

25 20 15 13 4 5

C C

10

Evaporator leaving leaving water water temperature, temperature, 00C C Evaporator

B B

114

A A

133

30HXC

YTHMA NEPOY
AQUASMART - ELECTRONIC CONTROL

017 - 033)

A SOLUTION FOR ALL SEASONS


From below -10C to above 45C the Aquasmart System rapidly adjusts the parameters to deliver the required temperature.

PROGRAMMED ENERGY AQUASNAP SAVINGS 30RAThe / RH (040 -controls 240) up to 128 terminals system

42N

in up to 32 zones, managing the chiller(s) / boiler(s) or heat pumps to minimise energy consumption whilst satisfying occupants need.

PROGRAMMED OR INDIVIDUAL CONTROL


Through the system manager user friendly and easily accessible menus allow quick system configuration and diagnostics, whilst individual adjustament is available to the occupants using the Carrier Room AQUASNAP Controller.

42GW

POPAMMA EEXO

30RY/RYH

42JW

(System Man Room

THREE FLEXIBLE PROGRAMS


OCCUPIED MODE: ensures comfort conditions are archivied for when employees arrive. ECONOMY MODE: ensures energy savings for the buiding owner during unoccupied periods. FROST PROTECTION MODE: ensures protection of the building maintaining a pre-programmed minimum temperature in the building and saving energy during holiday periods.


42WH

W/RWA - 300)

42EL

: . TIATIKH .

134

AQUASMART - OOKHPMENO YTHMA NEPOY CONTROLS

YTHMATA NEPOY AQUASMART

AQUASNAP JUNIOR 30RA / RH (005 - 013) AQUASNAP 30RA / RH (017 - 033)

AQUASNAP 30RA / RH (040 - 240)

AQUASNAP 30RY/RYH

116

09FC

30RW/RWA (020 - 300)


135

AQUASMART

PRO-DIALOG PLUS & MAESTRO

CONTROL SYSTEM PRO-DIALOG Plus MODELS


PRO-DIALOG Plus control. PRO-DIALOG Plus control (for 30RA and 30RH Aquasnap units). PRO-DIALOG TOUCH SCREEN for 30XA.

FEATURES
An advanced numeric control system, combining complex intelligence with great operating simplicity. Ensures intelligent leaving water temperature control and optimizes energy requirements. Equals compressor start-ups and running time.

PID control algorithm anticipates load variations, guarantees leaving water temperature stability and prevents unnecessary compressor cycling. Adjustable ramp loading, avoids too fast and too frequent load increases.

Provides preventive protection and enhanced unit reliability.

Monitors all safety parameters. Fault history function and 80 fault codes for immediate fault location.

Lead-Lag operation (standard).

136

Controls system

CONTROL SYSTEM maestro FEATURES


The main functions of the controller are: Controlling room temperature. Selecting occupied or unoccupied mode. Controlling the occupied set-point. Controlling room air renewal. Halting control function if window is open. The Maestro Zone Controller (Zc) is a numerical communicating controller with programmable parameters, attached directly to the terminal unit. The control system consists of a Maestro Zone Controller, one or more water flow control valves, a Zone User Interface (ZUI) or wall-mounted thermostat located in the air conditioned zone (accessories), a Maestro Power Module (Pm) for controlling lights and window blinds (accessory). Quick connectors simplify maintenance work and reduce servicing costs.

MODELS
Two available models: Maestro Zone Controller for water applications. Maestro Zone Controller for water electric heater applications.

137

COMFORT ZONE II

OPTIONALS SYSTEM ENHANCEMENTS


Programmable controller. Alarm indicators. Carrier command centre software. Mechanical ventilation. Multiple zone dampers. Smart sensors. Electronic air cleaners and central humidifiers. Humidity control and display. Outside air temperature display.

A zoning system providing owners of small commercial buildings with a practical way to manage energy end eQuipment operating costs while providing extremely high levels of comfort. FEATURES
Centrilised heating and cooling control while providing personalised comfort. Comfort zone II brings individual temperature and time control without the prohibitively high cost of multiple heating and cooling units.

Energy and operating cost savings, in addition to lower initial cost.

Easily programmed to suit specific requirements.

Divedes the building into as many as eight different comfort zones, based on their different heating and cooling requirements. Using a network of electronic thermostats, sensor and strategically placed, electronically-controlled dampers, Comfort Zone II maintains a comfortable environment in every zone.

138

ZONING SYSTEM

COMFORT ZONE II SYSTEM

1
ZONE CONTROLLER

2
ZONE SENSOR

3
ZONE DAMPER OR BY-PASS DAMPER

4
LINEAR DIFFUSOR

5
THERMOSTAT

139

CARRIER SOUTH EASTER EUROPE S.A. 18, Kifissou Avenue, 104 42 Athens Greece Tel.:+30 2106796300 Fax:+30 2106796390 www.carrier.com CARRIER BULGARIA SOFIA BRANCH Bul. Dr. Petar Dertliev 25, 1335 Sofia, Bulgaria Tel.:+35 929483960 CARRIER ROMANIA Str. Turnu Magurelev 270D, Et. 2, Sector 4 RO-041713 Bucharest, Romania Tel.:+40 21405 0751

February 2009 The manufacturer reserves the right to change the product specifications, data and images without notice.

Das könnte Ihnen auch gefallen