Three identical pumps were relocated and experienced high vibration issues when put into a new service with an operating speed range of 3,560 to 6,000 RPM. Root cause analysis found the vibration was due to structural resonance of the pump and pedestals at around 5,100 RPM, as well as an overhung mode critical speed of the rotor at around 4,700 RPM due to a heavy coupling. Recommendations included adding bracing to the pedestals to increase their natural frequency away from resonance, as well as replacing the coupling with a lighter profiled one. These changes reduced vibrations and allowed the pumps to operate through their full speed range.
Three identical pumps were relocated and experienced high vibration issues when put into a new service with an operating speed range of 3,560 to 6,000 RPM. Root cause analysis found the vibration was due to structural resonance of the pump and pedestals at around 5,100 RPM, as well as an overhung mode critical speed of the rotor at around 4,700 RPM due to a heavy coupling. Recommendations included adding bracing to the pedestals to increase their natural frequency away from resonance, as well as replacing the coupling with a lighter profiled one. These changes reduced vibrations and allowed the pumps to operate through their full speed range.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
Three identical pumps were relocated and experienced high vibration issues when put into a new service with an operating speed range of 3,560 to 6,000 RPM. Root cause analysis found the vibration was due to structural resonance of the pump and pedestals at around 5,100 RPM, as well as an overhung mode critical speed of the rotor at around 4,700 RPM due to a heavy coupling. Recommendations included adding bracing to the pedestals to increase their natural frequency away from resonance, as well as replacing the coupling with a lighter profiled one. These changes reduced vibrations and allowed the pumps to operate through their full speed range.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als PDF, TXT herunterladen oder online auf Scribd lesen
25 th International Pump Users Symposium Michael Singer Sulzer Pumps (US) Inc. Portland, OR Joel Walker Sulzer Pumps (US) Inc. Odessa, TX 2 Installation 3 stage BB3 type Water injection service (1200 GPM @ 2650 ft) Driven through gearbox by natural- gas engine 3560 to 6000 RPM continuous operating speed range 3 Problem Vibration Performance High bearing housing and casing vibrations showed after the pumps were relocated and put into a new service (Ran fine in previous life) Same problem with 3 identical units Horizontal vibration (~0.6 in/sec) at or above 5200 RPM Not able to reach full speed (6000 RPM) 4 Root Cause Analysis PIH Structural Resonance Impact Testing Impact tests show a horizontal structural resonance at approximately 85 Hz (5100 cpm) on pump inboard and outboard end 5 Root Cause Analysis Pump Lateral Rotordynamics High speed operation. (6000 RPM) Heavy coupling. (~100 lbs total) Long shaft span at drive end. Nearest seal is eye of suction impeller. 6 Root Cause Analysis Overhung mode critical speed (~4700 RPM) Low damping Large coupling orbit 7 Root Cause Analysis Replace coupling Lateral stability improved Recommendations 8 Root Cause Analysis Not every seam welded Uncertain hold-down locations Support Structure Modal FEA 9 Root Cause Analysis Horizontal pump mode 84Hz [5040 cpm] Mode shape offers clues to detuning Support Structure Modal FEA 10 Root Cause Analysis Add gussets / struts Box the pedestals Predicts increase in natural frequency 136 Hz [8160 cpm] Recommendations 11 Implementation Bracing added to all four pedestals (as piping allowed) 12 Implementation Drive-end pedestals also 'Boxed' to reduce twisting 13 Implementation Coupling Changes Original 48 lbs (pump-side) Profiled 36 lbs (pump-side) Field Balanced Entirely new 13 lbs (pump-side) 14 Results Reduced Vibration Original 0.60 in/sec @ 5200 RPM Added Struts 0.28 in/sec @ 5800 RPM Changed Coupling 0.19 in/sec @ 6100 RPM Ability to run through entire operating speed range 15 Lessons Learned Avoid unnecessarily heavy couplings. Open communication facilitates root cause analysis. Fix problems when found, as found. Relocating equipment and/or changing services including speed range can result in vibration issues.