Sie sind auf Seite 1von 1

101-D-0001

FEED SURGE DRUM

16"-LPF-101007302-101CH2F-N

29
3625

NOTE 5

LO
FB

35

33
32
31
30

27

03

ZHXS
NOTE 17 0039

ES

BY-PASS POSITIONER OPEN

03

ZHA
0039

ZYC
0039

ZLO
0039

3/4"

18"x8"
3/4"

NOTE 6

ZYV
0039

ZYV
0103

CLOSED

IA CLOSED

IA

ZLC
0039

DE

DE

ZLO
0103

ZYC
0103

ZHS
0039

ZY
0039

ZLS
0039 O

ATM

ZLS
0039 C

101CS1P
101CH2F

ZV
0039

21

ZV
0103

10"-HCB-101006005-103CS1P-H
HYDROCARBONS
3689FROM 101-S-0002-A/B

1/4"
L3B

ZY
0103

ZHS
0103

LT
0004 AB

LT
0004 BB

03

INST. PIPING

18

3/4"-LPF-101007303-101CH2F-N

29

NC

03

101-D-0001

ZC
0001

PIPING INST.

2"

ZC
0002

L1F

24"

03

LG
0050 C

INST. PIPING
A NOTE 18

PIPING
INST.

2"

L1D

03

2"
L1E

INST.
PIPING

NC

12
11

L1B

LL

L1C

LI
0004 A

6"-HCB-101008002-101CS1P-P

13

HH

INST. PIPING
1/4"

INST. PIPING

2"

1/4"

8
7

LT
0004 BA

LT
0004 CA

2"

LY
0004

3"

DIESEL FEED
LC
HIGH LEVEL
0004 C OVERRIDE

FEED
SELECTOR

LC
0004 B

TO CDU/VDU

DS101-TRJR-480043

KERO FEED
HIGH LEVEL

ZC
0030

OVERRIDE

6875

SIGNAL

DS101-TRJR-480043

SIGNAL
TO FCC
LLCO FEED
DS101-TRJR-480043

SIGNAL
TO FCC
HCN FEED
DS101-TRJR-480043

6876

6874

6873

TO FY-0076

ZC
0040

ZC
0025

03

SIGNAL

ZC
0024

SIGNAL TO

SIGNAL

SIGNAL

SIGNAL

FCC HCN FEED

TO CDU/VDU

TO FC-0002

TO FC-0001

DS101-TRJR-480043

DS101-TRJR-480043

DS101-TRJR-480040

DS101-TRJR-480040

7434

5564

3773

6898

ZC
0004
ZC
0005

ZC
0021

ZC
0023

ZC
0024

ZC
0025

ZC
0030

23

ZC
0031

ZC
0037

ZC
0038

ZC
0041

ZC
0042

ZC
0043

ZC
0044

22

ZC
0045

ZC
0046

ZC
0047

ZC
0049

ZC
0050

ZC
0051

ZC
0058

ZC
0056

ZC
0057

ZC
0039

GENERAL HOLDS
HOLDS

TYPE
HEIGHT
DIAMETER
OP. PRESS.
OP. TEMP.
DES.PRESS.
DES.TEMP.

mm
mm
barg
C
barg
C

101-D-0001
VERTICAL
11180.0
3450.0
2.00
77.00
5.00 NOTE 4
120.00
NOTE 8

This document is the property of SATORP and shall not be disclosed to third parties or reproduced without permission of the owner.

03

14

ZLC
0008

13

ZLO
0008

ZYC
0008

03

ZHA
0008

12

10

ZLS
0008 C

ZLS
0008 O

ZY
0008

ZHS
0008

SC

FC 03
TSO

2"

1
2
3- ALL LINES CONNECTED TO CLOSED DRAINS SYSTEMS SHALL BE GRAVITY FLOW DESIGNED.
4- DRAIN VALVE ON EQUIPMENT AND/OR PIPING SHALL BE INSTALLED FLANGE TO FLANGE OR AT MINIMUM DISTANCE FROM THE EQUIPMENT/PIPING TO BE DRAINED. 3
4
NOTES
5
1, 3 DELETED.
6
2- FOR SULFIDING.
7
4- DES. PRESS: PRESSURE 5 barg AND HALF VACUUM (HV) AT 150C.
8
5- MAKE CONNECTION ON TOP OF PIPE.
9
6- BLOCK VALVE SHALL BE INSTALLED WITH STEM IN OR BELOW THE HORIZONTAL POSITION.
7- MECHANICAL LINK.
10
8- MIN DES.TEMP 0C.
11
9- FOR NOZZLES DETAILS, ALIGNMENT AND HEIGHT OF LEVEL INSTRUMENTS SEE MECHANICAL DRAWING.
12
10- FOR SAMPLE DETAILS, REFER TO DWG. SA-JER-DS101-TRJR-480232.
13
03
11- CONNECTIONS FOR NITROGEN AND LP FLARE TO BE PROVIDED.
14
12- COMMON RESET SHALL BE CONFIGURATED IN BLOCK AND BLEED VALVES CASES.
13- COMMON RESET SHALL BE CONFIGURATED IN SIL 3 VALVES.
15
14- PZV-0001-A/B SIZE HAVE BEEN CALCULATED TAKING INTO ACCOUNT CV RATED OF PV-0003-A (CV=17.2) AND ITS BY PASS (CV=11.5).
16
15- SET PRESSURE OF PZV-0001A/B HAS BEEN READJUSTED BASED ON A DISTANCE FROM UPPER TL OF 101-D-0001 TO PZV. THIS DIFFERENCE OF ELEVATION
17
SHOULD NOT BE HIGHER THAN 4.1m.
18
16- CONNECTIONS TO BE ACCESIBLE AT GRADE.

DESCRIPTION
FIRE WATER
SERVICE WATER
COOLING WATER
POTABLE WATER
DEMI WATER
N.A.
N.A.
N.A.
HP STEAM
MP STEAM
LP STEAM
HP CONDENSATE
MP CONDENSATE
LP CONDENSATE
BFW
PLANT AIR
INSTRUMENT AIR
N.A.

14"-HCB-101007003-209CS1P-H

HYDROCARBONS
TO 101-G-0001

6
3690

NOTES 2, 11,16

NC

2"-HCB-101007012-209CS1P-P

4
3

6"-HCB-101008002-101CS1P-P
NO POCKETS

3"-HCB-101007006-209CS1P-N

HYDROCARBONS
FROM 101-G-00013691

209CS1P
101CS1P

REF. DWG POS.

101-153
101-152
101-153

101-151

101-151
101-151
101-154
101-154

19
20
21
22
23
24
25
26
27
28
29
30
31
32

DESCRIPTION
N.A.
FUEL OIL
FUEL GAS
N.A.
N.A.
N.A.
CLOSED DRAIN
N.A.
L.P. NITROGEN
H.P. FLARE
L.P. FLARE
SOUR/ACID FLARE
PILOT GAS
AUX COOLING WATER

2
1

03

05-APR-2011

AFC

AFC: APPROVED FOR CONSTRUCTION

VSC / STG

AVS / HPR

HS

02

22-DEC-2010

AFC

AFC: APPROVED FOR CONSTRUCTION

JGT / STG

AVS / HPR

HS

25

01

18-MAY-2010

AFC

AFC: APPROVED FOR CONSTRUCTION

JVM / FCB

RDP / HPR

HS

3840

00

23-DEC-2009

IFD

IFD: ISSUED FOR DESIGN

NPS / STG

RDP / HPR

HS

PREPARED BY

CHECKED BY

DATE

UTILITIES IDENTIFICATION
POS.

2"

MIN.

OSW

GENERAL NOTES

NO POCKETS

101-SP-0007

3/4"-HCB-101007006-209CS1P-N

3/4"-HCB-101007005-209CS1P-H
NOTE 10

10 MIN.

LPT

CL300

SC-0003
TYPE 21

DV

3"-CLD-101007301-101CS1P-N

1- EACH INSTRUMENT TAG NUMBER IS PREFIXED BY 101 (EX 101-TT-0001). THIS DRAWING IS VALID FOR TWIN LP HDS: UNITS 101 AND 102.
2- FOR GENERAL NOTES, SYMBOLS AND DETAILS SEE DRAWINGS SA-JER-DSAAA-TRJR-480001 THROUGH SA-JER-DSAAA-TRJR-480022.

19

15

REV

17- 1oo2D VOTING LOGIC BETWEEN SIGNALS ZHXS/HIXS-XXXX-A (HARDWIRED SIGNAL) AND ZHXS/HIXS-XXXX-B (MCB).
18- DISTRIBUTOR.

20

CLOSED OPEN POSITIONER BY-PASS

14"-HCB-101007002-101CS1P-H

3/4"-OSW-101007302-101CS1P-N

21

ZC
0055

ZV
0008

ZC
0031
ZC
0055

ZC
0018

MIN.

HS
0024

ZC
0003

ZC
0017

24

11

3/4"-HCB-101007006-209CS1P-N

KERO / DIESEL

ZC
0013

2
1

ZYV
0008

101CS1P
209CS1P

ZC
0012

101CS1P
209CS1P

LC
0004 A

ZC
0011

ATM

03

3"-OSW-101007301-101CS1P-N

ZC
0010

ZC
0003

DE

3"-HCB-101007008-101CS1P-H

ZC
0009

IA

MIN.
14"

RESET

ZC
0041

LG
0050 A

2"-HCB-101007010-101CS1P-P
B

ZC
0008

NOTES 12,13

INST.
NC PIPING

UC

MIN.
3/4"

2oo3

2"

3000 mm

LT
0004 AA

ZHXS
0008 L

2"
L1A
S

ZC
0003

17

ES

03

L2A

ZC
0070

ZHSR
0008

M2
ID

L4A

L3A

NC

24"

2"

10

INST.
PIPING

26

03

16

2"
03

NOTE 17

03

PIPING
INST.

2"

2oo3

27

18

NOTE 17

16

03

ZC
0006

HIXS
0003
LG
0050 B

15

HIXS
0002

25

PIPING
INST.

M1
ID

CL300

EMERGENCY SHUTDOWN
GENERAL

NOTE 9

L2B

2"

28

3/4"-HCB-101007011-101CS1P-N

3/4"

17

14

29

NOTE 5

101CH2F
101CS1P

2"

10"

10"-HCB-101007001-101CS1P-H

FC
TSO

FC
TSO

4" V

2"

1/4"

LT
0004 CB

03

30

4735

103CS1P
101CS1P

19

31

L4B

ZLS
0103 O

35

32

HPT

3" CL300
18"
CL300
W
E1

ATM
ZLS
0103 C

36

PC
0003

3/4"

2"

23
22

PT
0003

LO
FB
NOTE 6
18"-HCB-101007004-101CS1P-N

03

ZHA
0103

SPLIT
RANGE

PY
0003

PIPING INST.

OPEN POSITIONER BY-PASS

ZLC
0103

NOTE 5

3/4" D

INST. PIPING

37

3624

33

3/4"

PI
0058

CL300

29

34

PZV
0001 A
NOTES 14,15

3/4"
FB
LC

03

3"-LPF-101007301-101CH2F-N

NC

16"x10"

NOTES 14,15
CL300

101CS1P
101CH2F

24

20

3/4"

ZHSR RESET
0039

8"T10"
4,68

NNF

38

0.2%

2"

NOTES 12,13
+

26

18"x8"

NC

16"x10"

1"

8"T10"
4,68
PZV
0001 B

3/4" V

3/4"

ZC
0055

ES

03

LO
FB
NOTE 6

03

3/4" D

3"x2"

03 TSO
3/4" D
FC
CL300

MIN.

28

ZC
0040

101-SP-0056

3"-LPN-101007302-101CS1P-N

MIN.

ZHXS
0039 L

29

NOTE 7

3/4"-LPF-101007302-101CH2F-N

34

NOTE 6

03 FC
3/4" D
CL300

0.2%

2"

3"x2"

NO POCKETS

4737

36

25

3"-LPN-101007301-101CS1P-N

27

37

1-1/2"
3"x1-1/2"

3"x1-1/2"

3"-LPN-101007001-101CS1P-N

38

39

PV
0003 B

MIN.

PV
0003 A

40

250 mm MIN

39

50-100%

MIN.

TRIM: HCB-101007601-101CS1P
/ HCB-101007602-103CS1P
INSULATION: H

EMERGENCY SHUTDOWN
DESPRESSURIZATION

40

41

0-50%

101CS1P
101CH2F

41

COMPANY
STATUS

REVISION MEMO

APPR/AUTH BY

REF. DWG

101-155

JUBAIL EXPORT REFINERY


101-158

PIPING AND INSTRUMENT DIAGRAM

DISTILLATION AND HYDROTREATING


LOW PRESSURE HYDRODESULPHURISATION TRAIN 1

FEED SURGE DRUM

Project:

101-154
101-156
101-155
101-152

Item Tags :

101-D-0001

Syst./ S-Syst.:

COMPANY
Document N
Contractor/Vendor
Document N

ORIGINALSIGNEDINPROJECTFILE
Electronic Filename
SA-JER-DS101-TRJR-480003 .pid

Discipline: PRO

SA-JER-DS101-TRJR-480003
2271-101-PID-0021-007

REV: 03

Sheet: 1 of 1

SCALE: NONE
Format:

A1

Das könnte Ihnen auch gefallen