ABS HEAVY ANCHOR CE 1 WITH CLAMP

for cracked and non-cracked concrete


code FE210355 FE210360 FE210365 FE210370 FE210375 FE210380 FE210385 FE210390 do [mm] Lt [mm] d screw h1 [mm] tfix [mm] 10 10 12 12 15 15 18 18 75 95 107 127 118 138 117 147 M6 M6 M8 M8 M10 M10 M12 M12 65 65 80 80 95 95 105 105 10 30 30 50 25 45 10 40 Ch 10 10 13 13 17 17 19 19 Tinst [Nm] 15 15 30 30 50 50 80 80 pieces/box 50 50 50 25 25 25 10 10

certified CE Option 1 anchor for application on cracked and non-cracked concrete certificate of fire resistance F120 suited for applications on compact materials: stone, concrete designed for through fastening

RECOMMENDED LOADS CRACKED CONCRETE tension N (KN) share loads V (KN) torque (moment) M [Nm] CLS Rck C20/25 C30/37 C40/50 C50/60 C20/25 M6 2.4 2.9 3.4 3.7 10.1 6.9 M8 5.7 7.0 8.1 8.9 15.9 17.1 M10 7.6 9.3 10.7 11.8 20.5 34.3 M12 12.3 15.0 17.3 19.0 24.5 60.0

Loads determined based on the safety factors established by the ETAG. Lower loads apply for reduced centre distance, edge distances, and anchorage depths.

NON-CRACKED CONCRETE tension N [KN] Share loads V (KN) torque (moment) M [Nm]

CLS Rck C20/25 C30/37 C40/50 C50/60 C20/25

M6 7.6 7.6 7.6 7.6 10.1 6.9

M8 9.5 11.6 13.4 13.8 17.1 17.1

M10 14.3 17.4 20.1 21.9 27.5 34.3

M12 17.2 21.0 24.2 26.6 34.3 60.0

Loads determined based on the safety factors established by the ETAG. Lower loads apply for reduced centre distance, edge distances, and anchorage depths. GEOMETRIC INSTALLATION CHARACTERISTICS M6 Real anchor depth Minimum distance from edge Critical distance from edge Minimum centre distance Critical centre distance Minimum thickness of concrete support hef [mm] Cmin [mm] Cer,N [mm] smin [mm] ser,N [mm] hmin [mm] 50 50 75 50 150 100 M8 60 60 90 60 180 120 M10 71 70 106.5 70 213 140 M12 80 80 120 80 240 100

The values indicated refer to anchors installed which respect the distances indicated in the table. The anchor may also be used when these distances are not respected; naturally, there will be reductions in the load values due to variations in the installation parameters. LEGEND h1 = Minimum hole depth hef = Real depth of anchor tfix = Fixable thickness Lt = Anchor length Ch = Spanner Tinst = Tightening torque do = Stud diameter = hole diameter d = Screw diameter

143