certified CE Option 1 anchor for application on cracked and non-cracked concrete certificate of fire resistance F120 suited for applications on compact materials: stone, concrete designed for through fastening
RECOMMENDED LOADS CRACKED CONCRETE tension N (KN) share loads V (KN) torque (moment) M [Nm] CLS Rck C20/25 C30/37 C40/50 C50/60 C20/25 M6 2.4 2.9 3.4 3.7 10.1 6.9 M8 5.7 7.0 8.1 8.9 15.9 17.1 M10 7.6 9.3 10.7 11.8 20.5 34.3 M12 12.3 15.0 17.3 19.0 24.5 60.0
Loads determined based on the safety factors established by the ETAG. Lower loads apply for reduced centre distance, edge distances, and anchorage depths.
NON-CRACKED CONCRETE tension N [KN] Share loads V (KN) torque (moment) M [Nm]
Loads determined based on the safety factors established by the ETAG. Lower loads apply for reduced centre distance, edge distances, and anchorage depths. GEOMETRIC INSTALLATION CHARACTERISTICS M6 Real anchor depth Minimum distance from edge Critical distance from edge Minimum centre distance Critical centre distance Minimum thickness of concrete support hef [mm] Cmin [mm] Cer,N [mm] smin [mm] ser,N [mm] hmin [mm] 50 50 75 50 150 100 M8 60 60 90 60 180 120 M10 71 70 106.5 70 213 140 M12 80 80 120 80 240 100
The values indicated refer to anchors installed which respect the distances indicated in the table. The anchor may also be used when these distances are not respected; naturally, there will be reductions in the load values due to variations in the installation parameters. LEGEND h1 = Minimum hole depth hef = Real depth of anchor tfix = Fixable thickness Lt = Anchor length Ch = Spanner Tinst = Tightening torque do = Stud diameter = hole diameter d = Screw diameter
143