Ball Valves
Class 150 / 300 Cv Characteristics For 6 mm to 400 mm.
Cv rating shown below are for regular Port Ball Valves, witch may be used in formulae to size valves to any piping system. Please note that the chart enclosed pertains only to water at ambient temperature. Pressure drop for Full Port Ball Valves is same as for equal length of standard pipe of same size. Following formulas may be used to obtain accurate data for any other media. Cv is the number of gallons per minutes of water which will passthrough a given flow restriction with pressure drop of 1 psi.

P O O

NA WA L L A

P U O GR

Flow Characteristics Regular Port Valves Cv Valve Size 6-15 MM 20 MM 25 MM 30 MM 40 MM 50 MM 65 MM 80 MM 100 MM 150 MM 200 MM 250 MM 300 MM 350 MM 400 MM 2.2 3.3 9.5 13.0 22.0 31.0 68.0 95.0 169.0 314.0 518.0 927.0 1631.0 3004.0 4091.0

Liquid Flow Calculation

Gas Flow Calculation

p Q = 1.167 x Cv Q = 295 x Cv Sp Gr

P ) ( P1 + P2 )

( Sp Gr ) ( T )

(Q) (Sp Gr) or P= ( 1.167 ) x (Cv)

1.15 x 10-5 (Sp Gr ) (T) (Q) or P= (Cv) (P1 + P 2 )

Where Q = flow in Cubic Mtrs./Hr. Delta p = pressure drop Bar Sp Gr = specific gravity at flowing temperature Cv = Valve Flow Co-efficient

Where Q = Delta p = P1 = P2 = Sp Gr = T =

flow in Cubic Mtrs./Hr. pressure drop Bar Inlet pressure Bar (Absolute) outlet pressure Bar (Absolute) specific gravity (based on air = 1.0) C + 273

PRESSURE DROP Kg/Cm


0.014 0.021 0.028 0.035 0.040 0.049 0.056 0.063 0.070 0.140 0.210 0.281 0.351 0.703 0.632 0.421 0.492 0.562 0.007 9.1 13.65 18.2 22.75 27.30 31.85 36.4 41.05 45.5 6-15 20 20 30 91 136.5 182 227.5 2 3 4 5 6 7 8 9 10

50 60 70 80 90 100 150 50 200 300 400 500 80 600 700 800 900 1000 65

273.0 318.5 364 410.5 455 682.5 910 1365 1820 2275 2730 3185 3640 4091 4550 32

9000 13650 18200 22750 27300 31822 36370 40914 45460 250 200

2000 3000 4000 5000 6000 7000 8000 9000 10000

90920 136380 181840 227300 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0

20000 30000 40000 50000 4.0 5.0 6.0 7.0 8.0 9.0 10.0

PRESSURE DROP PSI Note : Water at Ambient Temperature. To convert U.S. Gallons into Imp. Gallons multiply by 0.93

WATER DISCHARGE IN US GALLONS PER MINUTE

40

WATER DISCHARGE IN LITRES PER MINUTE

40 100 150 300 350 400

0.1

0.2

Ball valves Pressure - Temperature Characteristics


Variation of max. non shock pressure w.r.t service temperature.
SERVICE TEMPERATURE IN F
3.6 57.6 147.6 237.6 327.6 417.6 507.6

SERVICE TEMPERATURE IN F MAXIMUM NON SHOCK PRESSURE RATING PSI.


57.6 120 110 100 90 147.6 237.6 327.6 417.6 507.6

MAXIMUM NON SHOCK PRESSURE RATING bar.

90 80
A SEAT

1160

A SEAT

1595 1450 1305

70

1015 870

60
B SEAT

80 70 60 50 40 30 20 10

1160 1015 870 725 580 435

50

725

C SEAT

40
D SEAT

580

B SEAT C SEAT D SEAT

PT

FE

CA

30
E SEAT

435

RB ON

FI LL

20

290

ED

33

290 145 0 300

10 0 -30 0 50 100 150 200 250

145 0 300

50

100

150

200

250

SERVICE TEMPERATURE IN C
Note: Values for regular port valves. For full port consider next smaller size.

SERVICE TEMPERATURE IN C

Seat Symbol Nominal Valve Size Seat Symbol Nominal Valve Size 8 to 25 RP A 200 & 250 RP D B 32 to 80 RP E 300 RP C 100 & 150 RP

Seat Symbol Nominal Valve Size Seat Symbol Nominal Valve Size 8 to 50 A 200 to 300 D B 65 to 100 E C 150

PTFE seats.
SERVICE TEMPERATURE IN F MAXIMUM NON SHOCK PRESSURE RATING bar.
1305 1160

CFT seats.

80

A SEAT

70
B SEAT

1015 870

60

C SEAT

50
D SEAT

725

40
E SEAT

580

30

435

20

290

10 0 -30 0 50 100 150 200 250

145 0 300

SERVICE TEMPERATURE IN C
Note: Values for regular port valves. For full port consider next smaller size. Seat Symbol A B C Nominal Valve Size 8 to 25 RP 32 to 80 RP 100 & 150 RP Seat Symbol D E Nominal Valve Size 200 & 250 RP 300 RP

25% GFT seats.

MAXIMUM NON SHOCK PRESSURE RATING PSI.

3.6 57.6 90

147.6

237.6

327.6

417.6

507.6 597.6

MAXIMUM NON SHOCK PRESSURE RATING PSI.

MAXIMUM NON SHOCK PRESSURE RATING bar.

597.6 1305

597.6 1740