Caterpillar Service Technology Group 30-Jan-02
171-4400
Function:
- Required PC software is included - CE Compliant - 4 times faster flash times with J1939 - Flash memory, no SPM - 4 DataLinks: ATA(J1708) RP1210 Compatible, Cat Data Link, J1939, DeviceNet (CAN) - Replaced 7X1700 Communications Adapter I - For more information, see NEHS0758 Getting Started Guide
177-8910
Function:
- Designed to accommodate a wide range of tractors & implements - Measures tractors with up to 18,160kg (40,000lbs) drawbar pull and 36,320kg (80,000lbs) max rating - Measures true ground seep and draft load - For more information, see PELJ0045 IRM & NEHS0768 Tool Operating Manual
187-8520
Function:
Wireless ET Communications
- Allows full ET functionality without being connected to the machine - 1.5 Mile range (Line of site) - Works with CA I & CA II - 2.4 GHz transmit and receive frequency - No license required - For more information, see PELJ0057 IRM
189-1720
Function:
- Used to test and troubleshoot analog temperature, pressure, fuel, & articulatoin gauges - Analog guage specifications provided - Decrease troubleshooting time and reduce cost by eliminating replacement of good parts - Fuse protected from electrtical overload - For more information, see PELJ0062 IRM & NEHS0786 Tool Operating Manual
191-3520
Function:
- Displays and prints fault codes and log codes - Snapshot datalogger - Displays engine rating information - CE Compliant - Requires 191-3521 Caterpillar Cartridge - For more information, see PELJ0055 IRM
Page 1 of 24
1U-6602
Function:
-
Photo-Tach Gp.
Measures RPM by directing light beam onto piece of reflective tape RPM can be measured to and is accurate within 1 RPM LCD viewed simultaneously while aiming the instrument Provides low cost tachometer for general use For more information, see SEHS8854 Special Instructions
1U-8860
Function:
-
Optional pickup for use with 8T-2700 Blowby/Airflow Group Large 38 mm (1.5 in) pickup used on large engines without increasing crankcase pressure All metal construction and alrge size makes tool suitable for permanent installation Can also measure air velocity such as radiator cooling air flow For more information, see SEHS8984 Service Manual
6V-2150
Function:
-
For machines that have automotive type key start and a diagnostic connector Allows one man to quickly check 14 test points in starting and charging system Identifies deteriorated starting and charging system components before they fail Requires 110-4645 Adapter Cable As.
7X-1400
Function:
- Displays diagnostic faults, Engine RPM, Engine Detonation Level, & Allows for calibration - Part of 146-2727 G3600 Operator Tool Gp. - Requires NEXG4511 Service Program Module
8T-1000
Function:
Measures dynamic and static rack position & other linear measurements
- 3 separate storage memories record minimum, maximum, and difference values - Digital readout (0-1) range 0 - 25.4mm - 8T-1001 Indicator powered with internal 9-volt battery; AC power adapter available - For more information see SEHS8623 Special Instructions & NEHP5597 Brochure
8T-2700
Function:
- Volume of blowby gases very helpful in planning engine repairs - Air velocity helpful to quickly find plugged or partially restricted areas - Battery-powered digital indicator - Part of 146-2726 Maintenance Tool Gp. - For more information see SEHS8712 Special Instructions
Page 2 of 24
8T-5200
Function:
-
Small handheld square-wave generator Used to simulate speed in place of magnetic speed pickup Frequency counter when unput is pulsating For more information, see SEHS8579
9U-6958
Function:
-
Used to check magneto performance during actual operating conditions When used with 146-4080 Digital Multimeter, user can measure magneto output DC Voltage Provides separate voltage output for oscilloscope viewing of firing pulse train Does not require power to operate
9U-7400
Function:
Multitach II Gp.
- Easy to use photo pickup for fast RPM measurement - Two digital displays show Input 1 and Input 2 values simultaneously - Backlit display for low light conditions - Rechargable batteries - Accepts many different types of pickups (Including some Multitach I pickups) - For more information see NEHS0605 Tool Operating Manual & NEHP5596 Brochure
9U-7401
Function:
Multitach II
- Easy to use photo pickup for fast RPM measurement - Two digital displays show Input 1 and Input 2 values simultaneously - Backlit display for low light conditions - Rechargable batteries - Accepts many different types of pickups (Including some Multitach I pickups) - For more information see NEHS0605 Tool Operating Manual & NEHP5596 Brochure
9U-7402
Function:
- Easy to use photo pickup for fast RPM measurement - Two digital displays show Input 1 and Input 2 values simultaneously - Backlit display for low light conditions - Rechargable batteries - Accepts many different types of pickups (Including some Multitach I pickups) - For more information see NEHS0605 Tool Operating Manual & NEHP5596 Brochure
9U-7500
Function:
-
Transmission Analyzer
Easy to read menus, on backlit LCD dislay step you through sequence of operation Performs: Solenoid Condition Check, Transmission Shifts of all gears, & Shift Lever test Flash memory allows internal software to be upgraded. Subscription NETG5021 For more information, see NEHP5617 Brochure & NEHS0644 Tool Operating Manual CE Compliant
Page 3 of 24
156-1060
Function:
-
Used for fast and easy set-up and servicing of lean burn and stoichometric engines Measures exhaust concentrations of O2, CO2, NO, and NO2 Built in thermal printer and Automatic water dump For use on Gas Engines Only - CE Compliant For more information, see PELJ0020 IRM & NEHS0713 Tool Manual
156-1070
Function:
-
Used to set-up, service, & monitor natural gas & diesel engine emissions
Used for fast and easy set-up and servicing of lean burn and stoichometric engines Measures exhaust concentrations of O2, CO2, NO, NO2, and CxHx Measures exhaust and ambient temperatures, stack draft, and smoke test Built in thermal printer and Automatic water dump - CE Compliant For more information, see PELJ0020 IRM & NEHS0713 Tool Manual
170-8500
Function:
Particle Analyzer
- Provides instant feedback on effectiveness of filtration, abnormal wear conditions, and overall system cleanliness - Allows real-time testing of repaired units - Touchscreen Interaction - Internal Battery - CE Compliant
188-0645
Function:
- Provides instant feedback on effectiveness of filtration, abnormal wear conditions, and overall system cleanliness - Allows real-time testing of repaired units - For more information, see NEHS0777 Instruction Manual & PELJ0050 IRM - CE Compliant
146-4080
Function:
- True RMS Digital Multimeter - Full Function Digital Measurements - Can be used with DataView to log any type of electrical signal (Requires 146-8488 Cable) - Provides 10th channel input for DataView - CE Compliant - For more information, see JEDG6000 Brochure & NEHS0554
6V-7070
Function:
- Easy to use - Very Durable - CE Compliant
Digital Multimeter
Page 4 of 24
9U-7330
Function:
Multimeter - Fluke 87
- True RMS Digital Multimeter - Measures: ACV, DCV, Amp, Hz, Duty Cycle, Diode, Temp, & Impedence - CE Compliant
142-5055
Function:
-
Used to measure and check insulation resistance for electrical power generation Analog scale reads up to 10 GW for high insulation resistance readings Meter ranges from 100 kW digital & 10 MW analog to test for faults on motors & generators Tool defaults to voltmeter operation whenever an external voltage greater thant 25 VAC/DC Replaces 9U-6003 Insulation Tester
152-7213
Function:
C66974T1
A CO M B
- Dual channel digital scope and dual channel true-RMS DMM - Brilliant high contrast backlit LCD with hardened scratch-resistant lens - AUTO key for fast, rock stable waveform displays of signals down to 1 Hz - Frequency range: 20 Hz at input - CE Compliant - For more information, see NEDG6011 Brochure
F2 F3 F4
mV V s TI
B
Hz
V HO LD RU N
ME
ns
mV
OP ER TIO NS
SC OPE MEN U US
SA PR VE IN T
AU
TO
163-0096
Function:
Process Calibrator
- Calibrates thermocouples, RTD's, voltage, resistance, Hz, Ma - CE Compliant - Stores up to 8,000 readings - Multilingual operation - Products requiring us of calibrator: 3600 Engine Protection Systems, Marine Monitoring Systems, 3600 Engine Management Systems, 3600 Custom Program Logic Control - For more information, see PELJ0023
4C-5521
Function:
- Provides positive identificaion of phase sequence of energized 3 phase 40-60 Hz power lines from 100 to 600 Volts - Gives user inidication that all phases have continuity or will indicate phase that has fault - Has heavily insulated fused leads for users protection - Enhanced durability because there are no moving parts
9U-5222
Function:
-
Voltage Detector - AC
Safe, quick, and easy way to locate energized circuits Good tool choice when looking for open fuses or circuit breakers or even broken wires Both audio and visual indicators For more information, see NEHS0564 Tool Operating Manual
Page 5 of 24
155-5175
Function:
AC Current Probe
- Measure up to 1000 Amps AC with standard Digital Multimeter - Used with 6V-7070, 9U-7330, or 146-4080 Digital Multimeter - Replaces 6V-4960 AC Current Probe - CE Compliant
155-5176
Function:
- Measure up to 1000 Amps AC/DC with standard Digital Multimeter - Used with 6v-7070, 9U-7330, or 146-4080 Digital Multimeter - Replaces 9U-5795 AC/DC Current Clamp - CE Compliant
6V-9130
Function:
- Used with 9U-7330 or 6V-7070 Digital Multimeter Groups - Kit converts Included Type K Thermocouple to mV readable by standard Multimeters - CE Compliant - For more information, see SEHS8382
8T-0900
Function:
- Measure AC/DC Current up to 1200 Amps - Digital Readout on handle - Used with 6V-7070, 9U-7330, & 146-4080 Digital Multimeters
1U-8115
Function:
6V-7072
Function:
- Deluxe Test Lead Kit for all Meters - Includes Alligator Clips, Test Leads, & Banana Leads - For use with 6V-7070, 9U-7330, & 146-4080 Digital Multimeters - CE Compliant
Page 6 of 24
7X-1710
Function:
Probe Gp.
- Allows user to measure electrical signal from connector without separating connector - Used with 6V-7070, 9U-7330, & 146-4080 Digital Multimeter Gp.
164-3310
Function:
Infrared Thermometer
- Full Featured Infrared Thermometer -32 - 900 C (-25 - 1600 F) - Bar Graph Display - Laser Circle Shows Size of Area being Measured - CE Compliant - For more information, see NEHP6016 Datasheet
164-3320
Function:
Infrared Thermometer
- Full Featured Infrared Thermometer r -32 - 900 C (-25 - 1600 F) - Log Up to 100 Readings - PC Data Graphing Software - 110V Charger - CE Compliant - For more information, see NEHP6016 Datasheet
166-9030
Function:
Infrared Thermometer
- Full Featured Infrared Thermometer -32 - 900 C (-25 - 1600 F) - Log Up to 100 Readings - PC Data Graphing Software - 220V Charger - CE Compliant - For more information, see NEHP6016 Datasheet
192-3750
Function:
Infrared Thermometer
- Small compact size -32 - 400 C (-25 - 750 F) - Accuracy of +/- 1% of Reading - For more information, see NEHP6016 Datasheet - CE Compliant - Replaces 148-2388 Infrared Thermometer
192-3755
Function:
Infrared Thermometer
- Small compact size -32 - 600 C (-25 - 1100 F) - Calculates max, min, & average temperatures - For more information, see NEHP6016 Datasheet - CE compliant - Replaces 148-2400 Infrared Temperature Tool
Page 7 of 24
213-4310
Function:
-
Infrared Thermometer
Low Cost Infrared Thermometer -20 to 260 C (0 to 500 F) Temperature Measurement Range Circle Laser CE Compliant
4C-6090
Function:
- Measures 16 temperatures individually - Allows serviceman to read individual cylinder exhaust temperatures to locate faulty injector - Used with 6V-7070 & 9U-7330 Multimeters with 6V-9129 Temperature Adapter - OR Used with 146-4080 Multimter with type K Measurement capability - For more information, see NEHS0537 Special Instruction
4C-6500
Function:
- Fast and accurate method of measuring temperature - Backlit, digital LCD Display for use in low light conditions - Large Display for easier viewing - Provides user with differential temperature measurement between 2 and 5 channels - For more information, see NEHS0554
8T-2844
Function:
Recorder Gp.
- Used for checking operating temperatures of the cooling, engine oil, hydraulic, & brake systems - Quick, easy, inexpensive method to determine component's surface temperature - 6 silver colored temperature sensitive indicator windows on each recorder - 5 different temperature recorders for 5 different ranges
146-1738
Function:
- 305mm (1ft) shaft, 6.53mm (.25 inches) diameter - Includes 90 degree mirror tube for right angle viewing - Adjustable focus - Portable battery light source - For more information see NEHS0504 Tool Opeating Manual & PELJ0046 IRM
8T-9290
Function:
- Fits into bores as small as 8mm (.32") and reach 240mm (9.5 inches) - Battery handle can be remotely coupled to scope using extension cable (supplied) - For more information see NEHS0504 Tool Operating Manual & PELJ0046 IRM
Page 8 of 24
1U-5268
Function:
-
Borescope
580 mm (23 in) Length, 6.5 mm (.25 in) Diameter Allow straight viewing of internal surfaces Used with Light Source 1U-56266(110 VAC) 190-8160 (220V) & 1U-5265 (Battery) For more information see NEHS0504 Tool Opeating Manual & PELJ0046 IRM
9U-6940
Function:
- 6.50mm (.256 inches) probe diameter, 570mm (22.5 inches) working length - Housing eliminates surface mirror scratching problem - 60 Degree Field Of View - Fits through nozzle hole on engines using a "pencil style" injector - Used with Light Source 1U-56266(110 VAC) 190-8160 (220V) & 1U-5265 (Battery) - For more information see NEHS0504 Tool Opeating Manual & PELJ0046 IRM
186-0170
Function:
- 6mm (.256 inches) probe diameter, 600mm (24 inches) working length - The flexible portion of the borescope is waterproof and resistant to 60 deg. C (140 deg. F) - For more information see NEHS0504 Tool Opeating Manual & PELJ0046 IRM - Used with Light Source 1U-56266(110 VAC) 190-8160 (220V) & 1U-5265 (Battery)
186-0180
Function:
- 14mm (.551 inches) probe diameter, 940mm (37 inches) working length - 140 degree adjustable direction of view with 45 degree field of view - Sealed tip to prevent contamination from oil or fuel - Used with Light Source 1U-56266(110 VAC) 190-8160 (220V) & 1U-5265 (Battery) - For more information see NEHS0504 Tool Opeating Manual & PELJ0046 IRM
1U-5266
Function:
- Compact, lightweight - Uses 150 watt light bulb, light intensity is adjustabl - Inlcudes a fan to prevent overheating - Bulb is protected with a 2 amp fuse - Alternative Tool: 190-8160 Light Source (220 VAC) - Used with 1U-5268, 9U-6940, 186-0170, and 186-0180 Borescopes
190-8160
Function:
Light Source
- Uses 150 watt light bulb, light intensity is adjustable - Compact, lightweight - Inlcudes a fan to prevent overheating - Bulb is protected with a 2 amp fuse - Alternative Tool: 1U-5266 Light Source (110 VAC) - Used with 1U-5268, 9U-6940, 186-0170, and 186-0180 Borescopes - For more information see, NEHS0504 Operation Manual & PELJ0046 IRM
Page 9 of 24
1U-5265
Function:
- Used with 1U-5268, 9U-6940, 186-0170, & 186-0180 Caterpillar Borescopes - 110 V Rechargabel Light Source for Caterpillar Borescopes - For more information, see NEHS0504 & PELJ0046 IRM
1U-5470
Function:
5P-8558
Function:
- 3 Gauges of 0.5% accuracy with pressure ranges of 1100 kPa (160 PSI), 4150 kPa (600 PSI) and 34,500 kPa (5000 PSI) - Two lower pressure gauges protected from excessive pressure by two sensor valves - A separate source of pressure is required to actuate the calibrating group
6V-7830
Function:
Tetragauge
- Functions as general purpose pressure measurement device - Capable of measuring hydraulic or air pressure - Range -100 kPa (-14.5 psi) to 40,000 kPa (+5800 psi). - 8T-5324 Repair Kit available to service this device
1U-7318
Function:
- Allows user to test continuity - Can be used as flashlight - High impact plastic - Magnet allows hands free use
5P-7277
Function:
Tester - Voltage
- Used to make quick checks for presence of voltage - Indespensable for checking out circuits, relays, bulbs, wires, & switches - Designed for voltage range from 12 to 36 Volts - Bulb lights brightly when connected to 36 Volts and dims progressivly with lower voltages - Uses standard 8D-1429 Bulb
Page 10 of 24
8T-0500
Function:
- Used to test non-energized circuits; lamp comes on brightly when connected across low resistance circuit - Designed for rugged field use - Comes with light bulb (6V-3061) and 2 N Size batteries (4c-8363) - Replaces canceled 8S-4627 Circuit Continuity Tester
177-2330
Function:
- Automatically Tests 6V & 12V Batteries - CE Compliant - Analyzer Checks for State-of-Charge, Condition, and Voltage - Batteries are Tested in the Machine - No Need to Remove - Temperature compensating circuit for cold batteries - For more information, see PELJ0037 IRM & NEHP6014 Datasheet
4C-4911
Function:
-
Two, easy to read LCD Displays show accurate measurements of Voltage & Current Voltage measured to one hundredth of a volt for accurate readings Heavy-Duty carbon pile, leads, and clamps - 1000 Amp Load Capacity Fan cooled, internal fan turns on when load is applied For more information, see NEHS7633 Special Instruction
4C-6600
Function:
Battery Voltmeter
- Designed to quickly determine voltage state of battery 6 - 60 Volts DC - Easier and faster than using a hydrometer to measure specific gravity - Battery voltage is displayed on a bright, red LED display
1U-7297
Function:
-
Temperature Comensated Can be used on either hot or cold radiators Can also accurately check some types of permanent antifreeze, such as Dowtherm 209 Alternative Tool: 1U-7298 Coolant and Battery Tester (degrees C)
1U-7298
Function:
-
Temperature Comensated Can be used on either hot or cold radiators Can also accurately check some types of permanent antifreeze, such as Dowtherm 209 Alternative Tool: 1U-7297 Coolant and Battery Tester (degrees F)
Page 11 of 24
121-9588
Function:
- Replaces 121-9587 Removal Tool - For more information, see SEHS9615 Special Instruction
151-6320
Function:
175-3700
Function:
- Used to maintain and repair Deutsch DT style connectors (Square & Rectangle) on electronic engine harnesses - For more information, see SEHS9615 Special Instruction
190-8900
Function:
- Used to maintain and repair Deutsch HD style connectors (Round) on electronic engine harnesses - For more information, see SEHS9615 Special Instruction
124-5643
Function:
- Provides voltage test points for individual wires in electronic engine control systems - Used on 3119 HEUI in GM Highway Trucks - Used with 146-4080, 6V-7070, & 9U-7330 Digital Multimeters
125-3662
Function:
- HEUI bypass cable used to isolate & test sensors for faults
Page 12 of 24
127-6359
Function:
- Used to test injector and/or injectory harness - Allows wiring to an individual injector to be bypassed - Helps to isolate problem between injector or harness
129-2018
Function:
Provides access to data link from 40-pin ECM and powers service tools
- Allows power & communication to an ADEM II ECM when vehicle voltage is unavailable
134-5195
Function:
- 40 pin square C/D to A/B adapter cable. - Allows connection of 7X-171 Square A/B 40 pin to 3500 & 3600 engines
139-4166
Function:
- Used to connect either the ATA Data-link or the Cat (CDL) Data-link to the 7X-1700 CA I - Replaces cancelled 7X-1412 Cable Assembly and 7X-1570 Cable Assembly - Can be used with 171-4400 Communications Adapter II for ATA & CDL only
Connects ATA data-link or the CAT (CDL) data-link to 7X-1700 Comm Adapter
140-2266
Function:
Provides wire test points for electronic engine control system (ECM)
- Used to provide test points for individual wires in engine wiring harness - Harness has standard probe tips which allow technician to check signal - Used to test signal on limited circuits
143-4508
Function:
- Allows user to check engine timing via timing light & flywheel marks on G3408C Gas Engine - Allows check of primary signal going to each transformer - Cable installs between ignition wiring harness and valve cover connector - Used with 146-4080 or 9U-730 Digital Multimeter
Page 13 of 24
143-4509
Function:
- Allows user to check engine timing via timing light & flywheel marks on G3412C Gas Engine - Allows check of primary signal going to each transformer - Cable installs between ignition wiring harness and valve cover connector - Used with 146-4080 or 9U-730 Digital Multimeter
157-4829
Function:
- Connects 139-4166 Diagnostic Cable to J1939 under-dash diagnostic connector - 9 Pin to J1939 Adapter Cable
163-5443
Function:
- Allow user to determine condition of detonation sensor on 3400, 3500, & 3600 Gas Engines - For more information, see Page 13, May 1999 Engine News, "Testing Detonation Sensor For Proper Use" - Used with 146-4080, 9U-7330, or 6V-7070 Digital Multimeter
167-9225
Function:
Harness As.
- Attaches to the ADEM 2000 Engine harness connector or auxillary battery to service machine without power - Same as 129-2018, except for use with ADEM III - Required to bench flash the ADEM III ECM
196-0055
Function:
Cable - Serial
- Serial PC Cable connects 171-4400 Communications Adapter II to PC 7.62 m (25 ft) - Part of 171-4400 Comm Adapter II Group
1U-9710
Function:
Adapter Cable
- Used with 6V-2100 Multitach, 6V-3121 Multitach Group, 9U-7400 Multitach Group, and 6V-9060 Spark Timing Adapter Group
Page 14 of 24
207-6845
Function:
- Short Data Link Cable 51 cm (20 in) - Use with ATA, CDL, & J1939-1 - Part of 171-4400 Communications Adapter II Group - Works with cancelled 7X-1700 & 171-4400 Communications Adapters - Replaces cancelled 160-0133 Cable
208-0059
Function:
Cable Assembly
- Used to provide test point for all individual wires in Engine wiring harness of ADEM III - Connects between ECM and main wiring harness - Allow testing access to all 70 wires
7X-1395
Function:
Adapter - SI TDC
- 2 Pin Deutsch DT TDC Calibration Cable - Used with 7X-1695 cable to allow connection to TDC adapter for S. I. Engines
7X-1425
Function:
RS-232 Cable
7X-1686
Function:
Adapter Cable
7X-1688
Function:
Cable Gp.
Page 15 of 24
7X-1695
Function:
Cable - TDC
- Used on captive engine applications - Allows magnetic sensor to be connected to engine to input timing information to ECM - Used with 7X-1395 cable to allow connection to TDC adapter for S. I. Engines - Used with 8T-8697 ECAP & 7X-1400 DDT
7X-1714
Function:
- Cable used to connect 139-4166 Communication Adapter harness to under-dash Packard connector - Used with 7X-1700 Communications Adapter I & 171-4400 Communications Adapter II Gp.
7X-1715
Function:
- Square 40 pin A/B Breakout Cable allowing voltage checks on any wire or between wires - Makes troubleshooting of electronic engine control systems faster & easier - Use with 146-4080, 9U-7330, or 6V-7070 Digital Multimeters
7X-6370
Function:
- Used to service 3406 PEEC and 3176 engines - Provide test points for individual wires in wiring harness - Used with 146-4080, 9U-7330, & 6V-7070 Digital Multimeters
8T-8694
Function:
- Used for servicing 3406 PEEC & 3176 Engines - Allows user to troubleshoot engine control system by providing test points - 5 Pin Breakout Adapter Cable Assembly - For use with 8T-8697 ECAP
8T-8695
Function:
- Used for servicing 3406 PEEC & 3176 Engines - Allows user to troubleshoot engine control system by providing test points - 9 Pin Breakout Adapter Cable Assembly - For use with 8T-8697 ECAP
Page 16 of 24
8T-8726
Function:
- Used for servicing 3406 PEEC & 3176 Engines - Allows user to troubleshoot engine control system by providing test points - 3 Pin Breakout Adapter Cable Assembly - For use with 8T-8697 ECAP
9X-0248
Function:
- Used when servicing 3176 Engines - Allows user to perform electrical measurements on electronic engine controls - For use with 8T-8697 ECAP
9X-1160
Function:
6V-2012
Function:
- Inch Measurement - Contains complete set of measuring rods from 0-228.8 mm (0-9 in) stored in wooded case - Base is 76.2 mm (3 in) wide and uses 3.96 mm (5/32 in) rods.
6V-2034
Function:
Adapter
6V-6042
Function:
Point Gp.
- For use with 8T-1000 Electronic Position Indicator & 6V-7926 Dial Indicator - Has plastic box with divided tool holder, space to cut more slots for storage of extra points - Part numbers and sizes are shown on a chart inside the lid of the box. - Will fit all dial indicators with 4-48 thread
Page 17 of 24
6V-7030
Function:
- Millimeter Measurement - Contains complete set of measuring rods from 0-228.8 mm (0-9 in) stored in wooded case - Base is 76.2 mm (3 in) wide and uses 3.96 mm (5/32 in) rods.
6V-7059
Function:
Measures cylinder liner top flange thickness and valve lip thickness
- Micrometer used for measuring top flange thickness on cylinder liners - Used with 6V-2034 Adapter to measure valve lip thickness
6V-7926
Function:
- Use primarily for measuring off-engine timing dimensions when setting fuel pump lifters - Measurements are made with 25.4 mm (1 in) travel indicator and 5 contact points - Can also be used for accurate depth measurements up to 127 mm (5 in)
8T-0450
Function:
- Available to help determine thread size - The size of internal port threads, external adapter threads, and bolt threads can be measured with the tools in this kit - Works on Metric, BSP, and US Standard Threads
6V-2196
Function:
Microscope
- 20X microscope is recommended for checking crankshaft bearing surfaces - Accurate measurement is provided by a scale reading in 0.1mm increments - Used with 6V-6059 Microlite
6V-6059
Function:
Microlite
- Penlight used with 6V-2196 20X General Usage Microscope - Includes 6V-3061 Bulb - Requires 1U-9535 AAA Batteries (2)
Page 18 of 24
198-4240
Function:
- Quickly & easily determine system pressures, vacuum, differential pressure, & temperature - Easily locate pressure spikes with Min/Max function - Resolution to 1 psi/bar - Greater accuracy than standard handheld gauges - Recalibrates sensor with each use - CE Compliant - For more information, see PELJ0060 IRM, NEHP6021 Datasheet, & NEHS0818 Manual
6V-9060
Function:
- Used with 8T-5300 Timing Indicator required for 3304, 3306, & 3516 Engines
8T-5300
Function:
- Used to measure fuel injection timing for diesel engines - Checks operation of auto timing advance on euipped engines - Requires 8T-5301 Diesel Timing Adapter or 6V-9060 Spark Timing Adapter - Replaces 6V-3100 Timing Indicator Gp.
8T-5301
Function:
- Required for 300, 1100, 3200, 3300, & 3400 Series Engines - Used with 8T-5300 Timing Indicator Gp.
131-5050
Function:
DataView Gp.
- Has data logging capabilities - Works on ALL Caterpillar machines, new & old - Uses standard Cat sensors and replaces 15+ green sensor boxes - For more information, see NEHS0662 Tool Operating Manual & NEHP6016 Datasheet - Measures and records information from sensors installed on machine or engine - CE Compliant - Does not include PC or sensors
131-5051
Function:
- Has data logging capabilities - CE Compliant - Uses standard Cat sensors and replaces 15+ green sensor boxes - Measures and records information from sensors installed on machines and engines - Includes all accessories needed to operate DataView on a PC except sensors - For more information, see NEHS0662 Tool Operating Manual & NEHP6016 Datasheet
Page 19 of 24
154-8101
Function:
- Display not included - State-of-the-art gear-type flowmeters with temperature compensation - +/- 0.5% accuracy per flowmeter - Prevents starvation if plugged - For more information, see PELJ0021 IRM & NEHS0697 & NEHS0698 Tool Operating Manual -Additional Components: 1U-5306 Hose Gp, 8T-9820 Power Spply, 5P-7366 Power Cable
154-8102
Function:
- Display included - Prevents starvation if plugged - State-of-the-art gear-type flowmeters with temperature compensation - +/- 0.5% accuracy per flowmeter - Used with 154-8106 Fuel Flow Display - For more information, see PELJ0021 IRM & NEHS0697 & NEHS0698 Tool Operating Manual
168-7730
Function:
- +/- 0.5% accuracy per flowmeter - Prevents starvation if plugged - 3612 & 3616 engines require accumulators - Used with the 8T-9300 Fuel Flow Monitor, 9U-7400 Multitach, or 131-5051 DataView - For more information, see PELJ0033 IRM & NEHS0740/NEHS0741 Tool Operating Manual
168-7740
Function:
Measures diesel engine fuel burn rate on 3606, 3608, 3612, & 3616
- Inlcudes 154-8106 Fuel Flow Display - +/- 0.5% accuracy per flowmeter - Prevents starvation if plugged - 3612 & 3616 engines require accumulators - For more information, see PELJ0033 IRM & NEHS0740/NEHS0741 Tool Operating Manual
179-0710
Function:
Used to measure engine burn rate on 3116, 3126, C-9, 3208, 3304, 3406/08
- Includes 154-8106 Fuel Flow Display - Flowmeter burn rate: 4 LHP (1.05 GPH) to 260 LPH (69 GPH) - Flowmeter Accuracy: +/- 1% of reading, +/- 0.1 GPH - Flowmeter type: Positive displacement, piston. Temperature compensated & output scaling - For more information, see PELJ0042 IRM & NEHS0776
179-0711
Function:
- Does not Include 154-8106 Fuel Flow Display - Flowmeter burn rate: 4 LHP (1.05 GPH) to 260 LPH (69 GPH) - Flowmeter Accuracy: +/- 1% of reading, +/- 0.1 GPH - Flowmeter type: Positive displacement, piston. Temperature compensated & output scaling - For more information, see PELJ0042 IRM & NEHS0776
Used to measure engine burn rate on 3116, 3126, 3176, 3208, 3304, 3406/08
Page 20 of 24
143-4062
Function:
- 0 to 689 kPa (0 to 100 psi) - Used with 131-5050 or 131-5051 DataView Gp. - For more information, see NELG5023 Sensor List - Low cost
143-4065
Function:
- 0 to 6890 kPa (0 to 1000 psi) - Low cost - Used with 131-5050 or 131-5051 DataView Gp. - For more information, see NELG5023 Sensor List
143-4066
Function:
- 0 to 51675 kPa (0 to 7500 psi) - Low cost - Used with 131-5050 or 131-5051 DataView Gp. - For more information, see NELG5023 Sensor List
153-9630
Function:
- Kit Includes: 153-9625 PWM Sensor Adapter - CE Compliant 153-9626 Break-Out Cable-HD 153-9627 Break-Out Cable-DT - Allows user to T into existing Cat sensors for measure and record using DataView - For more information, see NELG5023 Sensor List & PELJ0009 IRM
1U-9139
Function:
6V-4950
Function:
- Mounts to fuel line to measuer fuel pulses to determine RPM - Works on Perkins fuel lines as well as those with remote unit pump group - Works on precombustion chamber fuel systems & on some smaller direct injection systems - Used with 9U-7400 Multitach II & 131-5050 DataView - For more information, see SEHS8029 Special Instruction
Page 21 of 24
8T-5184
Function:
- Used with 8T-5300 Timing Indicator Group - Shorter (0.5") than the 6V-2197 transducer - [8.9 cm (3.5 in) long
8T-5185
Function:
- Used with 8T-5300 Timing Indicator Group - Longer (2.5") than the 6V-2197 transducer - 17.8 cm (7 in) long
1P-3537
Function:
- Useful for making critical bore measurement from 50.8 mm (2 in) to 203.2 mm (8 in) - Used to reconditioning cylinder bores on 1100 & 3100 series engines - Used to refinish connecting rods in 137.16 mm (5.4 in) bore V8 & V12 engines - Item #2 - See T&SPG (NENG2500) for other available models
5P-2170
Function:
- This gauge and its related masters provides accuracy to.0025 mm (.0001 inch) for measuring all bores in the size range 19.05-38.10 mm (.750 inch to 1.500 inch). - Particularly useful for measuring the relief valve spool bores in pressure control bodies on 631, 633, 637, 641,650, 651, 657, 660, and 666 Tractors with eight speed transmissions. - See T&SPG (NENG2500) for other available models
6V-6000
Function:
- Item #2; Used with 6V-6030 Size Setting Fixture (Item #1 - See T&SPG (NENG2500) for other available models
6V-6030
Function:
- A precision measuring instrument with a diameter range of 30 - 50.8 mm (1.2 - 2 in) graduated to 0.002 mm (.00008 in) increments - Item #1 - Used with 6V-6000 Dial Bore Gauge (Item #2) - For more information, see SMHS8036 Special Instruction
Page 22 of 24
6V-7897
Function:
Dial Indicator
- Dial Indicator used to convert 1P-3535 Dial Bore Gauge to the 6V-7898 Dial Bore Gauge - Used with 1P-3535 Dial Bore Gauge
6V-7898
Function:
Measures internal diameters (50 to 200 mm) & depths (13 to 300 mm)
- The dial bore gauge and size setting fixture will measure all internal diameters from 1.97 inch to 7.87 inch (50 to200 mm) and depths from 0.51 inch to 11.81 inch (13 to 300 mm) in increments of 0.00008 inch (0.002 mm). - Used with 6V-7899 Size Setting Fixture - See T&SPG (NENG2500) for other available models
6V-7899
Function:
- Used with 6V7898 Dial Bore Gauge - For more information, see SMHS8254 Special Instruction
123-6471
Function:
- Tester will display readings from both engine control and pump control systems - This hand-held tool features a 4 line, 16 character liquid crystal display (LCD) - For more information, see SEHS9825 Special Instructions, SENR6261 Test & Adjust Manual
Used to setup, test, calibrate, & troubleshoot M300 Series Wheeled Excavators
125-2580
Function:
- HEUI Diagnostic Tooling - Includes all necessary cables, harnesses, & pin removal tools - Injector and IAPC valve removal & installation tools - Modified injector clamp to aid in proper assembly and tightening of jumper tube - Necessary bit drivers and socket to work on hard-to-reach components - New double ended offset feeler gauge for setting valves
148-9610
Function:
- Durable painted steel with fiberglass top - Storage for up to 30 CDs in the door - PC installs inside with cooling fan - Internal power stripes provided - For more information, see NEDG6001 Datasheet & PELJ0013 IRM - CE Compliant - 150-8756 is 220V alternative cart
Page 23 of 24
8C-9801
Function:
- Provides additional function to measure frequency and duty cycle of PWM signals - Allows user to verify or diagnose operation of some sensors on electronic engines - Used with 8T-8697 Analyzer Programmer (ECAP)
8S-2257
Function:
- 12 X Power - 25.4 mm (1 in) Depth - Extremely Portable
Eye Loupe
9U-6695
Function:
- Adjustable sensitivity - user can set firing indicator to flash when placed near primary wire on exposed coils of 6.25 inch bore engines - Reliable tool to diagnose ignition problems - Flashing LED indicator easily seen in daylight
9U-7554
Function:
9U-7560
Function:
-
12V Cigarette Connector Field Soldering Iron Used with 4C-9024 Battery Pack Gp. or 12 volt source In line fuse prevents damage and/or overload For more information, see NEHS0601 Tool Operating Manual