FAV Meter

FEATURES
State of Art Microcontroller Based Design.
R Y B N R Y B KA

Built in Solid state selector switch for phase selection

V A

Super bright LED display for crystal clear long distance day light viewing All CT ratios user Programmable through front Key Pad. Built in Transducer Compact Size Four Digit Frequency Meter.

Hz
P
3P4W
2

50 60Hz

KAM-83

PARAMETERS
Volts : R-Y Voltage Y-B Voltage B-R Voltage R-N Voltage Y-N Voltage B-N Voltage : R Phase Y Phase B Phase : System

ADVANTAGES
Reduce Panel Space, Wiring , Installation Time Scale User adjustable reduces inventory

APPLICATION
Control Panel Distribution Systems Generator Sets Motor Control Test Bench

Amps

Frequency

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Temp Humidity Weight : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V 110VAC 50Hz (-20% +15%) : < 4 VA : 110 / 415 / 440 VAC ( L - L )500Vmax : 1 Amps / 5 Amps : < 0.2 VA : 0 - 55 C : < 90% RH ( non condensing) : 500 gms Accuracy : Voltage : 0.5 % of FS + 2 Digit Current : 0.5 % of FS + 2 Digit Frequency : + 0.02 Hz Resolution: Volts Hz Amps : 1V : 0.01 Hz : 0 - 99 : 0.1 A 100 - 999 : 1A > 1000 : 0.01 KA Dimension : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

FAV+ Meter
KAM 83M
R V Avg

FEATURES
V I1 I

Y I Avg

B L-L

I2 Hz

V Avg I Avg OL

S I UV OV PR

I3

P
3P4W
2

KA

50 60Hz

KAM-83M

POWER ANALYZER
FEATURES
State of Art Microcontroller Based Design. 4 Line Ultra Bright Red LED display to show phase
W VA VAh

Wh YAr
VArh L1 L2 L3

wise & System Parameters on same page.


A K PF Hz V(L-L) V(L-N) M

Site Programmable CT & PT Ratio. True RMS measurement. Auto Scrolling Facility. Password protection

Avg Sys Cal

EEprom retains Energy Parameters on power fail. Monitors Import & Export Energy. Computer Interface ( RS 485) Pulse Output for PLC / SCADA interface Optional: Data Logging of all Parameters with Date & Time

P
3P4W
2

50 60Hz

KM-161

stamp ( site programmable logging time interval).

PARAMETERS
Volts Amps Frequency Power Factor KW KVA KVAr KWh KVArh KVAh : L - L, L - N ( Per Phase & Avg.) : Per Phase & summation : System : Per Phase & Avg : Per Phase & Summation : Per Phase & Summation : Per Phase & Summation : Import, Export & Summation : Capacitive & Inductive : Total

ADVANTAGES
To caution on the Extra Energy Consumption To indentify inefficiency of Machine / Man Reduce Panel Space, Wiring , Installation Time Scale User adjustable reduces inventory

APPLICATION
Control Panel Distribution Systems Generator Sets Motor Control Test Bench APFC Panel Energy Management Process Control & SCADA

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Communication Temp Humidity Weight : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V / 110 VAC 50Hz (-20% +15%) : < 4 VA : 110 / 415 / 440 VAC ( L - L )500Vmax : 1 Amps / 5 Amps : < 0.2 VA : RS485 (Modbus - RTU Protocol) 9600 baud : 0 - 55 C < 90% RH ( non condensing) : 700 gms Accuracy : Voltage Current Active Power Reactive Power Apparent Power Power Factor Active Energy Reactive Energy Frequency : 0.5 % of F.S. + 2 Digit : 0.5 % of F.S. + 2 Digit : Class1.0 IEC 61036 : Class1.0 IEC 61036 : Class1.0 IEC 61036 : + 1 Electrical : Class1.0 IEC 61036 : Class1.0 IEC 61268 : + 0.2 Hz

Dimension : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

POWER ANALYZER Plus


FEATURES
State of Art Microcontroller Based Design. 2 Solid state Relay Out Put configurable for cutoff / Alarm setting of any Parameter. Site Programmable CT & PT Ratio. True RMS measurement. Auto Scrolling Facility. Password protection EEprom retains Energy Parameters on power fail. Monitors Import & Export Energy. Computer Interface ( RS 485)
CAL P R1 R2

Pulse Output for PLC / SCADA interface Optional: Data Logging of all Parameters with Date & Time stamp ( site programmable logging time interval).

3P4W

P
50 60Hz

KM-161P

PARAMETERS
Volts Amps Frequency Power Factor KW KVA KVAr KWh KVArh KVAh THD Max. Demand : L - L, L - N ( Per Phase & Avg.) : Per Phase & summation : System : Per Phase & Avg : Per Phase & Summation : Per Phase & Summation : Per Phase & Summation : Import, Export & Summation : Capacitive & Inductive : Total : Volts & Amps : KVA / KW

ADVANTAGES
To caution on the Extra Energy Consumption To indentify inefficiency of Machine / Man Reduce Panel Space, Wiring , Installation Time Scale User adjustable reduces inventory

APPLICATION
Control Panel Distribution Systems Generator Sets Motor Control Test Bench APFC Panel Energy Management Process Control & SCADA

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Communication Temp Humidity Weight : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V / 110 VAC 50Hz (-20% +15%) : < 4 VA : 110 / 415 / 440 VAC ( L - L )500Vmax : 1 Amps / 5 Amps : < 0.2 VA : RS485 (Modbus - RTU Protocol) 9600 baud : 0 - 55 C : < 90% RH ( non condensing) : 700 gms Accuracy : Voltage Current Active Power Reactive Power Apparent Power Power Factor Active Energy Reactive Energy Frequency : 0.5 % : 0.5 % : Class1.0 IEC 61036 : Class1.0 IEC 61036 : Class1.0 IEC 61036 : + 1 Electrical : Class1.0 IEC 61036 : Class1.0 IEC 61036 : + 0.2 Hz

Dimension : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

Energy Meter

Kwh
P
REV

3P4W

z 50 60H

KM-34L

Energy Meter
FEATURES
State of Art Microcontroller Based Design. 6 Digit Ultra Bright Red LED Display for Clear long distance day light viewing
INT

All CT Ratio Site Programmable.


REV MF : 10

True RMS measurement. Resolution site programmable

KWh

Pulse Output for PLC / SCADA interface Reverse indication for wrong wiring polarity

3P4W

50 60Hz

EEprom retains Energy Parameters on power fail.

KM-513

ADVANTAGES
Energy Management System To caution on the Extra Energy Consumption CT Ratio Site Programmable reduces inventory

APPLICATION
Energy Audit Control Panel Distribution Systems Generator Sets

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Temp Pulse Width : 3 Phase 4 Wire / 3 Phase 3 wire : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 110 / 415 / 440 VAC ( L - L ) 500 V max : 1 Amps / 5 Amps ( Flush Model) : < 0.2 VA : 0 - 55 C : 400 msec. + 50 msec. Humidity : < 90% RH ( non condensing) Accuracy : Class1.0 IEC 61036 Dimension :Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm Weight :500 gms Resolution : 1Amps / 5 Amps 5A - 50 A 50A - 500A > 500 Amps : 0.01 & above : 0.1 & above : 1 & above : 10

Energy Meter Plus


FEATURES
State of Art Microcontroller Based Design. 6 Digit Ultra Bright Red LED Display for Clear long distance day light viewing 10 Digit Counter ( 2 pages)
INT

All CT Ratio Site Programmable. True RMS measurement. Direct 60 Amps. (continuos) Din rail enclosure Password protection

REV

KWh

Computer Interface ( RS 485) Pulse Output for PLC / SCADA interface EEprom retains Energy Parameters on power fail. Reverse Indication for wrong wiring polarity Optional

P
3P4W
2

50 60Hz

KM-513P

Dual Source Energy Meter with individual Energy Registering Counters for Source1 & Source 2

APPLICATION
Energy Audit Control Panel Distribution Systems Generator Sets

ADVANTAGES
Energy Management System To caution on the Extra Energy Consumption To indentify in efficiency of Machine / Man Power Billing.

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Temp Humidity Accuracy Communication Pulse Width : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 415 / 440 VAC ( L - L ) 500 V max : 1 Amps / 5 Amps ( Flush Model) : 60 Amps. Direct continuos ( Din Model) : < 0.2 VA : 0 - 55 C : < 90% RH ( non condensing) : Class1.0 IEC 61036 : RS485 ( Modbus - RTU Protocol )9600 baud :400 msec. + 50 msec. Dimension : Flush Model: Weight : 550 gms Dim.: Bezzel : 96 x 96mm Depth (behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm Din Model: Weight : 800 gms Dim.: Size : 150 x 72 mm (L x B) Height (From wall) : 115 mm Base :35 mm Rail / 2 x m4Screw Resolution: 1Amps / 5 Amps : 0.01 < 50 Amps : 0.1 < 500 Amps :1

Energy Meter

ON

000
Kwh

REV

3P4W

z 50 60H

KM-34

1 & 3 Phase Energy Meter


(60 Amps. Direct) (DIN MODEL) FEATURES
KWh Meter ( Class 1) Direct Connection up to 60 A max. Non-Resetable Electromechanical Display 6 + 1 Dgt. ( 0.1 Resolution)
ON
Cal

LED indication for Reverse Connection Power On LED ( flashing ) for Meter Healthyness LED indication for Energy Consumption Pulse output Standard feature Self Power Supply , Aux. Sup. 115 V AC / 230 V AC

KWh

Rev
Earth

1P
TRUE

50...60Hz

RMS

KM-1513C

SPECIFICATION
System Voltage : 1 Phase 2 wire : 230 V AC (P - N ).

PRODUCT DESCRIPTION
Kam Electronic Energy Meter is designed with precision IC's to compute active energy consumption of the load at any power factor under balanced or unbalanced condition. The meter is designed to accept Voltage & Current input directly, ( 415 V AC L-L) and 60 Amps. (max) respectively. No need to have any Multiplication Factor and direct energy consumption record is available with 0.1 resolution.

Voltage Burden : 0.2 VA max. Current : 60 Amps.( max) Direct

Current Burden : 0.2 VA max. Frequency Display Accuracy : 50 - 60 Hz : Electro Mech. Counter (6+1 Dgt.) : Class 1 ( EN61036)

LED Indication : A) Power ON B) Cal. / Int. C) Reverse Polarity Housing Dimension Mounting : ABS Material : 105 x 90 x 95 mm ( L x W x H) : Din Rail ( 35 mm Rail )

ON

KWh

Cal

Rev

TRUE

RMS

3P4W

50...60Hz

SPECIFICATION
System Voltage : Three Phase, Unbalanced Load : 415 V AC ( L - L ). Display Accuracy Pulse Output Pulse Width Housing Dimension Mounting

KM-3513C
: Electro Mech. Counter (6+1 Dgt.) : Class 1 ( EN61036) : Opto Isolated; : 400 m Sec. : ABS Material :105 x 90 x 95 mm ( L x W x H) : Din Rail ( 35 mm Rail )

Voltage Burden : 0.2 VA max. Current : 60 Amps.( max) Direct

Current Burden : 0.2 VA max. Aux. Sup. : 230 V AC ( -15 + 10 % )

Aux.Sup. Burden: 3 VA max. Frequency : 50 - 60 Hz

Power Factor Meter


FEATURES
State of Art Microcontroller Based Design.
R
SYS

Built in Solid state selector switch for phase selection Super bright LED display for crystal clear long distance day light viewing Built in Transducer True RMS measurement

Y B

COS

3P4W

50 60Hz

KM-166

PARAMETERS
Power Factor: R Phase Y Phase B Phase System

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Temp Humidity : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V /110VAC 50Hz (-20% + 15%) : < 3 VA Accuracy : + 1 Electrical Resolution : 0 .01 count

: 110 / 415 / 440 VAC ( L - L )500Vmax Dimension : Bezzel: 96 x 96mm : 1 Amps / 5 Amps Depth ( behind bezzel) : 80 : < 0.2 VA mm Panel Cut out : 92 x 92 mm : 0 - 55 C : < 90% RH ( non condensing) Weight : 500 gms

Watt Meter
FEATURES
State of Art Microcontroller Based Design. Built in Solid state selector switch for phase selection Super bright LED display for crystal clear long distance day light viewing All CT ratios user Programmable through front keypad Built in Transducer True RMS measurement
P
SYS

R Y B

KW

KM-2313

3P4W

50 60Hz

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input )500Vmax Current Input Burden on CT Temp Humidity : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V /110VAC 50Hz (-20% +15%) : < 3 VA : 110 / 415 / 440 VAC ( L - L : 1 Amps / 5 Amps : < 0.2 VA : 0 - 55 C : < 90% RH ( non condensing) Accuracy : Class 1.0 IEC 61036 Dimension : Bezzel : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm Weight : 500 gms Resolution: 1A - 10A : 0.001KW 11A - 100A : 0.01 KW 101A - 1000A : 0.1 KW 1001A - 9999A : 1 KW

PARAMETERS
Watts: R Phase Y Phase B Phase System

10

Power Factor & Watt Meter


FEATURES
State of Art Microcontroller Based Design. Built in Solid state selector switch for phase selection Super bright LED display for crystal clear long distance day
COS

light viewing All CT ratios user Programmable through front Key Pad

KW R Y B SYS

Built in Transducer True RMS measurement

P
3P4W
2

ADVANTAGES
Reduce Panel Space, Wiring , Installation Time

50 60Hz

KM-1623

Scale User adjustable reduces inventory

PARAMETERS
Power Factor : R Phase Y Phase B Phase System : R Phase Y Phase B Phase System

APPLICATION
Control Panel Distribution Systems Generator Sets Test Bench

Watts

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Temp Humidity Weight : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V / 110VAC 50Hz (-20% + 15%) : < 4 VA : 110 / 415 / 440 VAC ( L - L )500Vmax : 1 Amps / 5 Amps : < 0.2 VA : 0 - 55 C : < 90% RH ( non condensing) : 500 gms Resolution : Power Factor Watts 0.001KW : 0.01 : 1A - 10A 11A - 100A 101A - 1000A : 0.01 KW : 0.1 KW : Dimension : Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm Accuracy : Power Factor Watts : + 1 Electrical : Class 1.0 IEC 61036

11

1 Phase Volt Meter


FEATURES
3 1/2 Digit - Dual Slope A/D Conversion Super bright LED display for crystal clear long

V
1P
1

V
50 60Hz

distance day light viewing Built in Transducer compact size

1P

50 60Hz

KM-122

Ranges
DC mV : 0 - 200 mV DC V : 0 - 2 / 20 / 200V

SPECIFICATION
System Aux. Supply +15%) Burden on Aux. Voltage Input Temp Humidity Accuracy Weight : 1 Phase : 230V / 110VAC 50Hz (-20% : < 3 VA : See Range : 0 - 55 C : < 90% RH ( non condensing) : 0.5 % of FS + 2 Digit : 350 gms Dimension : 96 x 96 Model: Bezzel : 96 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm 48 x 96 Model: Bezzel: 48 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 44 x 92 mm

AC mV : 0 - 200 mV AC V : 0 - 2 / 20 / 100 / 200 / 500 V

1 Phase Ammeter
FEATURES
3 1/2 Digit - Dual Slope A/D Conversion Super bright LED display for crystal clear long distance day light viewing Built in Transducer compact size
1P
1

A A
1P
2

50 60Hz

50 60Hz

KM-011

SPECIFICATION
System Aux. Supply Burden on Aux. Current Input Temp Humidity Accuracy Weight : 1 Phase : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : See Range : 0 - 55 C : < 90% RH ( non condensing) : 0.5 % of FS + 2 Digit : 350 gms. 48 x 96 Model: Bezzel: 48 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 44 x 92 mm Dimension : 96 x 96 Model: Bezzel: 96 x 96 mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

Ranges
DC mA : 0 - 200 mA 4 - 20 mA DC A : 0 - 2 / 20 A

AC mA : 0 - 200 mA AC A : 0 - 2 / 20 A

12

3 Phase Volt Meter


FEATURES
R Y B RY YB BR

Built in Solid state selector switch for phase selection Super bright LED display for crystal clear long distance day light viewing Built in Transducer Compact size

V
3P4W

50 60Hz

KM-322

PARAMETERS
Volts: R-Y Voltage Y-B Voltage B-R Voltage R - N Voltage Y - N Voltage B - N Voltage

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input )500Vmax Temp Humidity : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 110 / 415 / 440 VAC ( L - L : 0 - 55 C : < 90% RH ( non condensing) Weight : 400 gms Accuracy : 0.5 % of F.S. + 2 Digit Resolution : 1 Volt Dimension : Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

3 Phase Ammeter
FEATURES
State of Art Microcontroller Based Design. Built in Solid state selector switch for phase selection Super bright LED display for crystal clear long distance day light viewing All CT ratios user Programmable, reduces inventory Built in Transducer Auto Ranging
3P4W
2

R Y B KA

A
50 60Hz

KM-031

SPECIFICATION
System Aux. Supply Burden on Aux. Current Input Burden on CT Temp Humidity Accuracy : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V 110VAC 50Hz (-20% +15%) : < 3 VA : 1 Amps / 5 Amps : < 0.2 VA : 0 - 55 C : < 90% RH ( non condensing) : 0.5% of F.S. + 2 Digit Dimension : Bezzel : 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm Weight : 450 gms

PARAMETERS
Amps: R Phase Y Phase B Phase

Resolution : 0 - 99A : 0.1 A 100 - 999A : 1A > 1000 A : 0.01 KA

13

Frequency Meter
FEATURES
State of Art Microcontroller Based Design.
Hi

Super Bright Red LED Display for Clear long distance day light viewing Four Digit Read out with 0.01 Resolution Built in Transducer Optional A) With High / Low Frequency Cutoff B) With High & Low Frequency Cutoff
P

Low

Hz

Hysterisis, Delay & Set point site selectable through front Keypad

KM-613P

APPLICATION
Automatic Mains Failure Panel Control Panel Distribution Systems Generator Sets

ADVANTAGES
To caution on the Frequency Level To indentify the faulty Generator To protect Motors & other Electrical & Electronic Equipments.

Hz

KM-613

SPECIFICATION
Aux. Supply Burden on Aux. Voltage Input Weight Temp Humidity Accuracy : 230V /110VAC 50Hz (-20% +15%) : < 3 VA : 30 - 500 VAC : 450 gms : 0 - 55 C : < 90% RH ( non condensing) : + 0 .02 Hz For Relay Output: Relay status : Energise on Trip Delay : 0.1 Sec. to 9.9 Sec. Hysterisis : 0.1 Hz to 3 Hz Relay contact : 6A / 230V AC / 28 VDC Resolution Dimension : 0.01 Hz :Bezzel: 96 x 96mm Depth ( behind bezzel) : 80 mm Panel Cut out : 92 x 92 mm

14

PVAF METER

Amp L1 Amp L2 Amp L3


L1 L2 L3

KW v Hz

P
3P4W
2

50 60Hz

KM-1215

15

Temperature Indicator & Sensor


FEATURES

R1

R2

PV

SV

SET

KM-209

ADVANTAGES

APPLICATION

KAM 100T

SET

KM-2019

SPECIFICATION
KAM KAM

16

Process Indicator

KM-169

Counter

KM-003

17

Earth Leakage Relay Plus

75

n % lD

60
0.6 1 2.5 5 10 0.25 0.5

45
10
20

n % lD TAIP

0.5 1 3

30 5

30

0.1

0.03

n(A) lD

0.15 0.06 0

ON

0.3

t(S) D

e Earth L Relay
TEST

a ka g e

RESET

KM-512R(PS)

Fixed ELR

KM-512R (F)

18

Earth Leakage Relay Plus


KM-512RP

FEATURES
State of Art Microcontroller Based Design Bar Graph display to indicate Leakage Current in percentage Consistent reliability with high accuracy Trip setting through Dip Switch selection Time Delay setting through Dip Switch selection Power ON indication for system Healthiness. Front Panel Sealing for Tamper proof. Alarm Relay at 50% of set Range to caution on Leakage current.

Sensitivity Ranges
Model 1 : Range : 30mA, 100mA,300mA, 500mA, 1 A & 3A Model 2 : Range : 1A, 2A, 3A, 5A, 7.5 A & 10 Amps. Also user specified Ranges

APPLICATION
Protection : Control Panel Feeder / motor Generator Transformer Electrical Dist.

SPECIFICATION
Aux. Supply Burden on Aux. Trip Point Delay Relays Relay Contacts Contact Rating Temp Humidity Dimension Mounting Weight : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : +/- 15% of the set range : 0.1 , 0.2, 0.3, 0.5, 1 & 3 Seconds. : 2 Nos. (Trip Relay & 50% Alarm Relay) : Potential Free Contact (NO&NC)SPDT : 6 Amps / 230 V AC/ 28 V DC : 0 - 55 C : < 90% RH ( non condensing) : 90 x 45 x 75 mm ( L x B x H) : Din ( 35 mm rail ) : 350 gms

Zero / Core Balance Current TR.


ID ( internal diameter): 35 mm 70 mm 120 mm Also user specified ID & Rectangular CBCT on request

Earth Leakage Relay


FEATURES
Consistent reliability with high accuracy Trip setting through Front Panel Potentiometer Time Delay user settable LED indication for healthy / faulty status Auto / Manual Reset option Compact size

KM-512R

SPECIFICATION
Aux. Supply Burden on Aux. Delay Relay Contacts Contact Rating Temp Humidity Dimension Mounting Weight : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 0.1 Sec. to 10 Sec. : 2 Potential Free Contact ( NO&NC) ( Energise on Trip) : 6 Amps / 230 V AC/ 28 V DC : 0 - 55 C : < 90% RH ( non condensing) : 78 x 55 x 97 mm ( L x B x H) : Din ( 35 mm rail ) / 2 x m4 screw : 450 gms

APPLICATION
Protection : Control Panel Feeder / motor Generator Transformer Electrical Dist.

Sensitivity Ranges
Range: 30 - 300 mA , 30 - 3000 mA 300mA - 3Amps,1- 4 Amps 1 - 8 Amps, 1- 10 Amps Also user specified Ranges

19

ELR Inbuilt CBCT

KM-512R(IB)

SPACE HEATERS
MORGAIN Inc. manufactures "Anti Condensation' Panel heaters in a wide range. KAM series heaters are extremely robust in construction and provide heating for a wide variety of applications. This type of heaters finds its specific use as "Anti-Condensation Heater" in most of the control gear and switchgear panel applications. The costing being economical makes this ideal for these applications.

FEATURES

KM-198

SPECIFICATIONS
Kam

20

UV, OV & PR Voltage Relay


FEATURES APPLICATION

MODELS
KAM KAM KAM

SPECIFICATION

KM-2112R

Under Voltage Relay with DRS

KAM KAM

KM-212R

21

Current Relay

KA

PF

AS

OV

UV

KM 003R

KM 003R

22

Voltage & Hz Relay

PR

PF

Hz

AS

OV

UV

VF
KM-228R

KM-228R

23

Earth Fault Relay


C1

FEATURES
Consistent reliability with high accuracy Trip setting through Front Panel Potentiometer Time Delay user settable LED indication for healthy / faulty status Auto / Manual Reset option Compact size

L N AUX.SUP.

A/M

C1 C2 INPUT

10%

30%

0-1SEC 10SEC

SET
UL A
TEST

DELAY
RESET

TY

EARTH FAULT RELAY

NO

COM

NC

NO

COM

NC

APPLICATION
KM-560R
Protection : Control Panel Feeder / motor Generator Transformer Electrical Dist.
Temp : 0 - 55 C

Input Ranges
Range: CTR / 1 Amps CTR / 5 Amps. DC V : 0 - 1 / 5 / 10 V DC mA : 0 - 1 / 10 / 16 / 20 mA 4 - 20 mA 2 - 10 mA

SPECIFICATION
Aux. Supply Burden on Aux. Delay Set Point Relay Contacts NC) Contact Rating : < 3 VA : 0.1 Sec. to 10 Sec.

: 230V / 110VAC 50Hz (-20% +15%)

Humidity : < 90% RH ( non condensing) Dimension : 78 x 55 x 97 mm ( L x B x H) Mounting : Din ( 35 mm rail ) / 2 x m4 screw Weight : 450 gms

: 20% - 80% : 2 Potential Free Contact (2 NO & ( Energise on Trip) : 6 Amps / 230 V AC/ 28 V DC

Over Load Relay


FEATURES
Consistent reliability with high accuracy Trip setting through Front Panel Potentiometer Time Delay user settable LED indication for healthy / faulty status Auto / Manual Reset option Compact size

APPLICATION
Protection : Control Panel Feeder / motor Generator Transformer Electrical Dist.

L N AUX.SUP.

A/M

C1 C2 INPUT

20%

SET
UL A

120% 0-1SEC 10SEC

DELAY
RESET

TEST

TY

OVER LOAD RE
NO COM NC NO

LAY
COM NC

KM-1512R

SPECIFICATION
Aux. Supply Burden on Aux. Delay Set Point Relay Contacts Contact Rating : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 0.1 Sec. to 10 Sec. : 20% - 120% : 2 Potential Free Contact (2 NO & NC) ( Energise on Trip) : 6 Amps / 230 V AC/ 28 V DC Temp : 0 - 55 C Humidity : < 90% RH ( non condensing) Dimension : 78 x 55 x 97 mm ( L x B x H) Mounting : Din ( 35 mm rail ) / 2 x m4 screw Weight : 450 gms

Input Ranges
Range: CTR / 1 Amps CTR / 5 Amps. DC V : 0 - 1 / 5 / 10 V DC mA : 0 - 1 / 10 / 16 / 20 mA 4 - 20 mA 2 - 10 mA

24

Signal Isolator / Convertor


FEATURES
L N AUX.SUP.

High Input / Output Isolation ( optical Isolation )


+
INPUT

POWER ON
ZERO

Ripple Free, Stable and High Accuracy Output External Span & Zero adjustment Low Internal consumption compact size Optional : Multiple output

SPAN

ISOLATOR

SIGNAL

OUTPUT + -

KM-199

Input Ranges
DC mV : 0 - 100 mV DC V : 0 - 1 / 5 / 10 V DC mA : 0 - 1 / 10 / 16 / 20 mA 4 - 20 mA 2 - 10 mA

Output Ranges
DC V : 0 - 1V ( Burden : 1K ) ) ) 0 - 5 / 1 - 5 V ( Burden : 5K DC mA : 0 - 1mA( Burden : 10K 0 - 5 mA( Burden : 2K ) ) ) ) 0 - 10 / 2 - 10 V ( Burden : 10K

SPECIFICATION
Aux. Supply Burden on Aux. Temp Humidity Accuracy Over Load Cap. Response time Isolation Dimension Mounting : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 0 - 55 C : < 90% RH ( non condensing) : Class 1.0 : 1.2 x rated voltage continuos 1.5 x rated voltage for 10 sec. : 0.5 Sec. : 2 KV ( 4 KV on request) : 78 x 55 x 97 mm ( L x B x H) : Din ( 35 mm rail ) / 2 x m4 screw

APPLICATION
INPUT to : Data Logging PLC SCADA Indicators Telemetering Recoders

0- 10 / 2 - 10mA ( Burden : 1K 0 -20 / 4 - 20mA( Burden : 500

Temperature / Watt Transducer


FEATURES
High Input / Output Isolation ( optical Isolation ) Ripple Free, Stable and High Accuracy Output External Span & Zero adjustment Low Internal consumption Compact size
INPUT
SPAN
POWER ON

WATT TRANSDUCER
+ OUTPUT

SPECIFICATION
Aux. Supply Burden on Aux. Temp Humidity Accuracy Response time Isolation Dimension Mounting Weight : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 0 - 55 C : < 90% RH ( non condensing) : Class 1.0 : 0.5 Sec. : 2 KV ( 4 KV on request) : 100 x 70 x 112 mm ( L x B x H) : Din ( 35 mm rail ) / 2 x m4 screw : Temperature : 500 gms Watt : 700 gms

Aux SUP. L N

KM-2032

Temp. Transducer Input Ranges


PT 100 : Temp.:0 - 50 C 0 - 100 C 0 - 200 C

Watt Transducer Input Ranges


1 Phase :- Volt : 0 - 300 V AC Amps : 0 - 8.33 A 3 phase :- Volts : 110 / 415 / 440 V Amps : 1A / 5A Over Load : 1.2 x rated voltage cont. 2 x rated current cont.

Output Ranges
DC V : 0 - 1V ( Burden : 1K ) ) ) 0 - 5 / 1 - 5 V ( Burden : 5K DC mA : 0 - 1mA( Burden : 10K 0 - 5 mA( Burden : 2K ) ) ) ) 0 - 10 / 2 - 10 V ( Burden : 10K

0- 10 / 2 - 10mA ( Burden : 1K 0 -20 / 4 - 20mA( Burden : 500

25

AC / DC Voltage Transducer
FEATURES
Stable and High Accuracy Output
L N AUX.SUP.

INPUT

External Span & Zero adjustment Low Internal consumption

POWER ON
ZERO

SPAN

TRANSDUCER

VOLTAGE

Compact size Optional : Multiple Output

OUTPUT + -

Input Ranges
AC V

KM-2220

DC V

: 0 - 63.5/ 110 / 230 300 / 440 / 500 VAC : 0 - 1000 V DC

Output Ranges
DC V : 0 - 1V ( Burden : 1K ) ) ) 0 - 5 / 1 - 5 V ( Burden : 5K DC mA : 0 - 1mA( Burden : 10K 0 - 5 mA( Burden : 2K ) ) ) ) 0 - 10 / 2 - 10 V ( Burden : 10K

APPLICATION
INPUT to : Data Logging PLC SCADA Indicators Telemetering Recoders

SPECIFICATION
Aux. Supply Burden on Aux. Temp Humidity Accuracy Response time Over Load Cap. Isolation Dimension Mounting Weight : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 0 - 55 C : < 90% RH ( non condensing) : Class 1.0 : 0.5 Sec. : 1.2 x rated Voltage continuos 1.5 x rated Voltage for 10 sec. : 2 KV ( 4 KV on request) : 78 x 55 x 97 mm ( L x B x H) : Din ( 35 mm rail ) / 2 x m4 screw : 400 gms

0- 10 / 2 - 10mA ( Burden : 1K 0 -20 / 4 - 20mA( Burden : 500

Current Transducer
FEATURES
Stable and High Accuracy Output
ZERO
L N AUX.SUP.

INPUT

POWER ON

External Span & Zero adjustment Low Internal consumption compact size Optional : Multiple Output

SPAN

TRANSDUCER

CURRENT

OUTPUT + -

KM-320

SPECIFICATION
Aux. Supply Burden on Aux. Temp Humidity Accuracy Response time Over Load Cap. Isolation Dimension Mounting Weight : 230V / 110VAC 50Hz (-20% +15%) : < 3 VA : 0 - 55 C : < 90% RH ( non condensing) : Class 1.0 : 0.5 Sec. : 2 x rated current continuos 10 x rated current for 10 sec. : 2 KV ( 4 KV on request) : 78 x 55 x 97 mm ( L x B x H) : Din ( 35 mm rail ) / 2 x m4 screw : 400 gms

Input Ranges
AC A : 0 - 1 A, 5A(direct) CTR / 1A, CTR / 5A

Output Ranges
DC V : 0 - 1V ( Burden : 1K ) ) ) 0 - 5 / 1 - 5 V ( Burden : 5K DC mA : 0 - 1mA( Burden : 10K 0 - 5 mA( Burden : 2K ) ) ) ) 0 - 10 / 2 - 10 V ( Burden : 10K

0- 10 / 2 - 10mA ( Burden : 1K 0 -20 / 4 - 20mA( Burden : 500

26

Engine Protection Unit

VDC
Over Speed

Stop Interval(S

ecs)

ON

Engine P rotection unit


Stop

Start

Reset

Ack

KM-516

Motor Protection Relay


R V Avg

V
I1

Y I Avg

I
I2

B L-L

Hz

V Avg I Avg
S I
OL UV OV PR

I3

P
3P4W
2

KA

50 60Hz

27

Timer

KM-020T

FORWARD REVERSE Timer

100 ON

0 100 REV

0 FOR

KM-618T

28

STAR DELTA Timer

100 ON

KM-194T

CYCLIC TIMER

100 ON

100
REV

KM-003T
29

Customised Panel

V
VDC

Y B VL-L KA V Avg

A
Over Speed
Stop Interv al(Secs)
P
2

Hz

ON

tion unit Engine Protec


Stop

Start

Reset

Ack

3P4W

50 60Hz

KM-316

30

Customised Panel

START

RESET STOP

tection Unit Engine Pro

KM-613A

31

Customised Panel

Wh R Vah Varh K

A V(L-N) W PF M V(L-L)

Var VA B CAL Avg Svs

S Hz

KM-316B

32

Customised Panel

Amp Amp
L1 L1

Amp Amp

L2 L2
Amp Amp
L3
KW KW
L1

L2 L2 L3 L3

Hz Hz

P P
3P4W
2

50 60Hz

KM-316C

33

Energy Audit Supervisor

KM-5119

PARAMETERS
Volts Amps Frequency Power Factor KW KVA KVAr KWh KVArh KVAh THD Max. Demand : L - L, L - N ( Per Phase & Avg.) : Per Phase & summation : System : Per Phase & Avg : Per Phase & Summation : Per Phase & Summation : Per Phase & Summation : Import, Export & Summation : Capacitive & Inductive : Total : Volts & Amps : KVA / KW

FEATURES
State of Art Microcontroller Based Design. Suitable for 1 Phase & 3 phase measurement 2 Solid state Relay Out Put configurable for cutoff setting of any Parameter to give Alarm Rugged portable casing Clamp on CT's Programmable CT & PT Ratio. True RMS measurement. Auto Scrolling Facility. Password protection

APPLICATION
Load Study & Analysis Energy Audit Plant Maintance Power Management Data logging

EEprom retains Energy Parameters on power fail. Monitors Import & Export Energy. Computer Interface ( RS 485) optically isolated Inbuilt Data Logger for storing all Parameters with Date & Time stamp for long duration Audit without manual intervention / operation

SPECIFICATION
System Aux. Supply Burden on Aux. Voltage Input Current Input Burden on CT Communication Temp Humidity : 3 Phase 4 Wire / 3 Phase 3 Wire : 230V / 110VAC 50 Hz (-20% +15%) : < 4 VA : 110 / 415 / 440 VAC ( L - L )500Vmax : 1 Amps / 5 Amps : < 0.2 VA : RS 485 (Modbus - RTU Protocol) : 0 - 55 C : < 90% RH (non condensing) Dimension: 455 x 360 x 150 mm ( L x B x H) Accuracy : Voltage Current Active Power Reactive Power Apparent Power Power Factor Active Energy Reactive Energy Frequency : 0.5 % : 0.5 % : Class1.0 IEC 61036 : Class1.0 IEC 61036 : Class1.0 IEC 61036 : + 1 Electrical : Class1.0 IEC 61036 : Class1.0 IEC 61036 : + 0.2 Hz

34