Sie sind auf Seite 1von 1

PROJECT :

CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pipe Concrete Column Design Based on ACI 318-11


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
fc'
REBAR YIELD STRESS
fy
COLUMN OUTSIDE DIAMETER
D
CONCRETE WEB THICKNESS
T
FACTORED AXIAL LOAD
Pu
FACTORED MAGNIFIED MOMENT
Mu
FACTORED SHEAR LOAD
Vu
COLUMN VERT. REINFORCEMENT
8
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
#
4

=
=
=
=
=
=
=
#

5
60
20
7
480
190
20
7
1
12

ksi
ksi
in
in
k
ft-k
k

Ties
in o.c.

THE COLUMN DESIGN IS ADEQUATE.

2 0.85 f

ANALYSIS

e o ===
900

f
700

500

'
C

, Ec

57

e
e c
2 c -<<

e
o
e o

'
C

, Es

400

for 0

eec

'
C

f Pn (kips)

300

29000ksi

, for eec o
,
for

eee
E
s
s
s y

=
,
for
>
f
ee
s
y

600

f Pn (k)

Ec

0.85 f
=

0.85 f

800

'
C

f Mn (ft-kips)

200

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD

819
819

0
70

100

AT 0 % TENSION

643

148

AT 25 % TENSION

533

180

AT 50 % TENSION

444

197

AT e t = 0.002

318

206

AT BALANCED CONDITION

313

208

AT e t = 0.005

146

229

164

0
0

50

100

150

200

250

f Mn (ft-k)

AT FLEXURE ONLY

CHECK FLEXURAL & AXIAL CAPACITY

f Pmax =0.85 f [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

Ag =
a = Cbb 1 =

819.14 kips., (at max axial load, ACI 318-11, Sec. 10.3.6.1)

0.65 + ( et - 0.002 ) (250 / 3), for Ties


where

Cb = d ec / (ec + es) =
d

Ast =

4.80

Pu

in2.

in (at balanced strain condition, ACI 10.3.2)

0.75 + ( et - 0.002 ) (50), for Spiral

f=

>

0.65 (ACI 318-11, Sec.9.3.2.2)


2
286 in .

in

17.56 in, (ACI 7.7.1)

f Mn = 0.9 Mn =

164

f Mn =

ft-kips @ Pu =

190

10

0.656

(ACI 318-11, Fig. R9.3.2)

et =

0.002069

b1 =

0.8

ec =

0.003

( ACI 318-11, Sec. 10.2.7.3 )

ft-kips @ Pn = 0, (ACI 318-11, Sec. 9.3.2) ,& et,min = 0.004, (ACI 318-11, Sec. 10.3.5)
480

>

kips

rmax

0.08 (ACI 318-11, Section 10.9)

rmin

0.01 (ACI 318-11, Section 10.9)

rprovd

Mu

[Satisfactory]

0.017
[Satisfactory]

CHECK SHEAR CAPACITY

f Vn = f (Vs + Vc) =

49

kips, (ACI 318-11 Sec. 11.1.1)

>

where

f =
A0 =

Vu
[Satisfactory]
0.75 (ACI 318-11 Sec. 9.3.2.3)
2
Av = 0.40
214 in .

Vc =

2 (fc')0.5A0 =

Vs =

MIN (d fy Av / s , 4Vc) =

smax

14

smin

30.3

in2.

fy =

60

ksi

12

in

kips, (ACI 318-11 Sec. 11.2.1)


35.1

(ACI 318-11, Section 7.10.5.2)

kips, (ACI 318-11 Sec. 11.4.7.2)


sprovd

[Satisfactory]

[Satisfactory]

Das könnte Ihnen auch gefallen