Beruflich Dokumente
Kultur Dokumente
Collection of Datasheets
R E F R I G E R AT I O N A N D A I R C O N D I T I O N I N G
Standard Compressors
Energy-optimized
Compressors
Tropical Compressors
P-Series
PL30F
PL50F (LST)
PL50F
T-Series
TTE3FK
TTE4F
Page 60
Page 62
T-Series
TFS4.5FT (LBP)
Page 90
TFS4.5FT (LBP/MBP) Page 92
N-Series
NLE5.5F
NLE6F
NLE7F
Page 64
Page 66
Page 68
S-Series
SC12FTX
SC15FTX
T-Series
TL2.5F
TL3F
TL4F
TLS4.5F
TF3F
TF3.5F
TFS4F
TT2.5F
Page 12
Page 14
Page 16
Page
Page
Page
Page
Page
Page
Page
Page
18
20
22
24
26
28
30
32
N-Series
NF6FK
NF7FK
NF9FK
NF9.5FK
NF5.5FX
NF7FX
NF9FX
NF10FX
NF11FX
NF6.1FX.2
NF7.3FX.2
NF8.4FX.2
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
F-Series
FF8.5FK
Page 58
34
36
38
40
42
44
46
48
50
52
54
56
High Energy-optimized
Compressors
T-Series
TTY5F
TTY6F
N-Series
NTY5.5FK
NTY6FK
NTY7FK
NTY9FK
NTY10FK
NTX5.2FK
NTX5.7FK
NTX7.3FK
CK.40.A5.22
Page 70
Page 72
Page
Page
Page
Page
Page
Page
Page
Page
74
76
78
80
82
84
86
88
Page 94
Page 96
Universal Compressors
T-Series
TL2.5G
TL4G (50/60Hz)
Page 98
Page 100
F-Series
FF6GK
FF7.5GK
FF8.5GX
FF10GX
Page
Page
Page
Page
S-Series
SC12G
SC15G
SC18G
Page 110
Page 112
Page 114
102
104
106
108
July 2003
1. General
This collection of datasheets contains information on Danfoss hermetic refrigeration compressors for 115V especially designed for refrigeration systems using refrigerant R134a
(CF3-CH2F).
The programme consists of the basic types PL, TF, TL, TT, NF, NL, NT, FF and SC.
8238-6
8238-11
8238-2
PL
FF
8238-13
SC
8238-3
TF/TT
TL
8238-12
8238-4
NF/NT
1.1 Compressor
designations
NL
Optimization
level
Compressor
size
Application
range
Generation
F
Blank
R134a LBP/(MBP)
First
FT
generation
R134a LBP/(MBP) tropical
TF, TL, TT
Nominal
FK
S
displacement in
2
R134a LBP/(MBP) LST
Semi-direct intake
cm3
Second
FX
NF, NL, NT
generation
R134a LBP/(MBP) HST
E
Exception:
G
Energy-optimized
For PL
3
R134a LBP/MBP/HBP
FF
(optimized motor)
compressors the
Third
GK
Y, X
generation
capacity at
R134a LBP/MBP/HBP LST
High Energy-optimized
rating point is
GX
SC
(high optimization level)
etc.
stated
R134a LBP/MBP/HBP HST
PL
Blank
Standard energy level
Example
July 2003
TF
4.5
FT
NL
FF
8.5
GX
NF
6.1
FX
CK.40.A5.22
2
3
1.2 Design
Compressors with the denominations PL, TFS, TLS, TTE, NLE, NF are designs with semidirect intake. Compressors with the denominations TTY and NTY are designs with direct
intake. Please note that the suction and process connectors on all TFS, TLS, TTE and TTY
compressors have been interchanged as compared with the normal TL compressors.
Using the wrong connector as suction connector on PL, TFS, TLS, TTE, NF, NL and NLE
compressors will lead to reduced capacity and efficiency.
Using the wrong connector as suction connector on TTY and NTY is not allowed since the
compressor will not function.
All compressors have a green label with the type
designation. This label has a blue stripe and the
text R134a.
NLE5.5F
Application
115V~60Hz
LBP LST
R134a
Barcode on
white background
5605
DANFOSS COMPRESSORS
8315-3
Blue stripe
Green background
Danfoss compressors have a manufacturing date code stamping on the housing. The form
mainly used recently is stamping into the top cover of the housing. On some compressor
production lines the stamping has been changed to needle printing into the side of the housing.
This is going to be introduced on all products.
For a certain period 2 different codes, in needle printing and cover stamping, will be used in
parallel. The coding is designed not to be mixed up with the previous version.
Example (recent date code):
L--4F-4400
F-203E1157
The first line states the model designation and the code no.
L= last letter (or last two letters) of the compressor type
-4F- = nominal displacement and application
4400 = 4 last digits in the code no.
(= position mark)
The second line states the date of manufacture and internal Danfoss codes.
F
= manufacturing place (F = Germany, AL = Slovenia, AM = Mexico)
20
= week 20
3
= 2003
E
= Friday (A = Monday etc.)
115 = nominal voltage
7
= internal Danfoss code
The country of origin (manufacturing place) is also stamped on the compressor cover.
CK.40.A5.22
July 2003
The build-in conditions (total height, weight, tube dimensions etc.) are specified in the individual datasheets including dimensional sketches for the compressors.
1.5 Compressor
dimensions
2. Application range
F Compressors with denominations ending with F are primarily designed for low evaporating
temperatures (LBP Low Back Pressure/MBP Medium Back Pressure on small displacements)
for use in refrigerators, freezers and similar applications in regions with stable supply voltage.
FT Compressors with denominations ending with FT are F-types designed for low evaporation
temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar applications operating in regions with unstable supply voltage.
FK Compressors with denominations ending with FK are F-types designed for low evaporation
temperatures with LST starting characteristics (capillary tube).
FX Compressors with denominations ending with FX are F-types designed for low evaporation
temperatures with HST starting characteristics (expansion valve).
G Compressors with denominations ending with G are primarily designed for high evaporation
temperatures (HBP High Back Pressure) for use in liquid coolers, dehumidifiers, refrigerated
display counters, vending machines and similar applications. The compressors can also be
used for Heavy Duty purposes at low evaporating temperatures for use in refrigerators, freezers
and similar applications operating in regions with unstable supply voltage.
GK Compressors with denominations ending with GK are G-types designed for high evaporating
temperatures with LST starting characteristics (capillary tube).
GX Compressors with denominations ending with GX are G-types designed for high evaporating
temperatures with HST starting characteristics (expansion valve).
The table on page 6 shows the normally recommended applications as regards voltage/frequency, ambient temperature, evaporating temperature and necessary compressor cooling.
The recommandations must be regarded as a guideline only as they presuppose a proper
dimensioning of the refrigeration system.
Condensing temperature
Winding temperature
July 2003
In order to secure a satisfying lifetime of the compressor, and to protect the compressor
against overload, some design criteria for the appliances must be fulfilled.
Both the condensing temperature and the compressor temperature should be kept as low as
possible. This can be done by using well-dimensioned condenser surfaces and by ensuring
good ventilation around the compressor under all operating conditions.
In order to protect the compressor against overload, the compressor has to start and work
properly through pressure peaks obtained in the highest ambient temperature and lowest obliging
voltage. At peak load the condensing temperature must not exceed 158F (70C). The winding
temperature must not exceed 275F (135C).
At stable operation conditions the condensing temperature must not exceed 140F (60C). The
winding temperature must not exceed 257F (125C).
These limitations secure protection of valves, gaskets, oil, and motor insulation
CK.40.A5.22
Compressor
PL30F
FT
S
O
F1
F2
*
**
=
=
=
=
=
=
=
TLS4.5F
TF3 - 3.5F
95 - 135 /60
TFS4F
95 - 135 /60
TT2.5F
TTE3FK
TTE4F
S*
TTY5 - 6F
S*
NLE5.5 - 6 -7F
S*
TFS4.5FT (LBP)
95 - 135 /60
TFS4.5FT (LBP/MBP)
95 - 135 /60
F1
F1
SC12FTX
95 - 135 /60
F2**
F2**
95 - 135 /60
F2
F2
90 -110 /50
F2
F2
90 -110 /60
F2
F2
95 - 135 /60
F1 (38C: S)
F1 (38C: S)
F2
NF9 - 9.5FK
95 - 135 /60
F2
NTY5.5 - 6FK
S*
NTY7 - 9 - 10FK
F1*
S*
FF8.5FK
F2
F2
NF5.5 - 7FX
95 - 135 /60
O/F1
O/F1
NF9FX
95 - 135 /60
F2
O/F1
NF10FX
95 - 135 /60
F2
NF11FX
95 - 127 /60
NF6.1 - 7.3FX.2
95 - 135 /60
O/F1
O/F1
NF8.4FX.2
95 - 135 /60
F2
O/F1
TL2.5G
90 - 127 /50
90 - 127 /60
O/F1
O/F1
O/F1
95 - 135 /60
F2
F2
SC12 -15G
SC18G
GK
GX
90 - 127 /60
103 - 127 /60
TL4G
90 - 127 /50
TL2.5 - 3 - 4F
NF6 - 7FK
FX
Ambient temperature
110F (43C)
LBP
MBP
HBP
PL50F
SC15FTX
FK
Power Supply
[V/Hz]
F1
F2
F2
FF6 - 7.5GK
O/F1
O/F1
O/F1
FF8.5 - 10GX
F1
F1
F1
The application limits regarding evaporating temperatures and motor systems are specified in the individual
compressor datasheets.
6
CK.40.A5.22
July 2003
3. Electrical equipment
8073
8087-2
Starting devices with PTC need a compressor standstill period of 5 minutes to cool down the
PTC before each start.
b) TT, NTE
8074
8074-2
c) FF-GK (alternative)
July 2003
CK.40.A5.22
Compressors with the motor type Resistant Start Capacitor Run (RSCR) have a starting
device for Low Starting Torque (LST). This starting device requires a pressure-equalized system before each start. This starting device is normally used in well-designed refrigerating
systems with capillary tube as throttling device. The design of the electrical equipment depends
on the actual compressor design. As shown in the drawings the following designs of starting
devices exist:
a) PTC + run capacitor + cord relief + cover,
the motor protector is built into the motor (winding protector)
b) PTC + run capacitor + motor protector + cover
b) NTE, NTY, TT
a) NLE
Compressors with the motor type Capacitor Start Induction Run (CSIR) have a starting device
for High Starting Torque (HST). This starting device requires no pressure-equalization before
each start and is normally used in refrigerating systems with expansion valve as throttling
device or in capillary tube systems where pressure equalizing is not obtained during the standstill
periods. The starting capacitor is designed for short time cut-in. 1.7% ED , which is stamped
on the starting capacitor, means for instance max. 10 cut-ins per hour each with a duration of
6 seconds. The design of the electrical equipment depends on the actual compressor design.
As shown in the drawings the following designs of
starting devices exist:
a) Relay + starting capacitor + cord relief + cover,
the motor protector is built into the motor (winding
protector)
b) Relay housing incl. motor protector + starting
capacitor with bracket + cord relief (2x) + cover
c) Relay housing incl. motor protector + starting
capacitor + cord relief (2x) + cover
d) Relay + starting capacitor + cord relief + cover
(SC)
e) Relay + starting capacitor (with bracket) + cover/
protector/protector holder (parts of compressor),
used for compressors with the denomination SC
which have an external protector.
8076
8087
8075
Starting devices with PTC need a compressor standstill period of 5 minutes to cool down the
PTC before each start. This starting device is mandatory for some compressor designs and it
is an option for others (specified in the invidual data sheets).
a) TL, TLS
This starting device is mandatory for some compressor designs and it is an option for others
(specified in the invidual data sheets).
8
CK.40.A5.22
July 2003
8077-2
8077
c) NF-X, TFS
8088
8467
b) FF-X
d) SC
3.4 Connections
e) SC (external protector)
The electrical components are equipped with connectors depending on the ordered code number,
1
Starting relays:
/4 in. (6.3 mm) spade connectors only
1
PTCs:
/4 or 3/16 in. (6.3 or 4.8 mm) spade connectors
The power supply must be connected as shown in the wiring diagrams for the chosen electrical
equipment given in the actual datasheets.
3.5 Approvals
THERMALLY
PROTECTED
8315-2
NLE5.5F
115V-60Hz
1PH
Approval mark
July 2003
CK.40.A5.22
4. Moisture and
Impurities
5. Max. refrigerant
charge
The refrigerant charge must never be too large to be contained on the condenser side of the
refrigeration system. Only the refrigerant amount which is necessary for the system to function
must be charged.
The refrigerant amount may be critical as regards oil foaming and liquid hammer after long
standstill periods. Because of this, limitations of refrigerant charges have been introduced.
The maximum refrigerant charge is specified in the individual datasheets.
If these limitations cannot be complied with, the risk may be reduced if a crankcase heater is
properly used or if a pump down system is established.
6. Oil charge
The compressors are supplied charged with dried and degassed oil, which is normally sufficient
for the lifetime of the compressor. The refrigeration systems and the system components
must be dimensioned in such a way that the oil can be lead back continuously to the compressor
housing without accumulating in the system, e.g. without oil pockets and with sufficient gas
velocity. The compressors use polyolester oils and are approved only for these oils and R134a.
The oil charge is specified in the individual datasheets.
7. Mounting
Soldering problems caused by oil in the connectors can be avoided by placing the compressor
on its baseplate some time before soldering it into the system. The compressor must never be
placed upside down when mounting the rubber grommets in the baseplate. Instead place the
compressor on its side with the connectors upwards.
Washer
Nut M6
Washer
Grommet sleeve
Steel pin
Compressor base
Clip
Compressor base
3327-2
7382-2
Cabinet base
Cabinet base
Screw M6 x 25
Rubber grommet
7.1 Mounting
accessories
Rubber grommet
Snap-on joint
The mounting accessories for the compressors are available in two versions, with bolt joint or
snap-on joint. The code numbers for the mounting accessories are specified in the individual
compressor datasheets.
These rubber grommets are designed for the 5/8 in. (16 mm) holes of the baseplate:
Bolt joint for one compressor in a bag 118 - 1917 (with screw M6 x 25 mm)
118 - 1946 (with screws 1/4 inch)
Bolt joint in quantities
118 - 1918 (with screws M6 x 25 mm)
Snap-on in quantities
118 - 1919
Snap-on for one compressor in a bag 118 - 1947
These rubber grommets are designed for the 3/4 in. (19 mm) holes of the baseplate:
Bolt joint in quantities
118 - 1949 (with screws 1/4 inch)
10
CK.40.A5.22
July 2003
8. Condition at delivery
The compressors are delivered without mounted starting devices on pallets with the dimensions
1144 x 800 mm. Quantities per pallets are specified in the individual datasheets. Electrical
components are packed in separate boxes.
The most important performance controls carried out during manufacturing are,
A high potential insulation test with 1650V for 1 second
Pumping capacity
Tightness of discharge side and discharge valve
Tightness of compressor housing
Check of the right oil charge
Noise test
The compressors are supplied with sealed connectors and the sealing should not be removed
before the system assembly takes place
(max 15 minutes with open connectors).
9. Conversion from
R12 to R134a
Normally, the capillary tube shall be adjusted at low evaporating temperatures. Compared to
an optimized R12 system with the same evaporator capacity, the R134a system must have
an increased resistance defined as approx. 10% less N2 flow at 10 bar inlet pressure.
The same size of capillary tube as used for R12 can be used at high evaporating temperatures.
A drier with 3 desiccant of Molecular Sieves must always be used.
Rules for dryness and cleanliness of system components (e.g. DIN 8964) are transferred to
R134a systems.
The system components must not contain mineral oil or greasy substances.
The compressors must be soldered into the system no later than 15 minutes after the connector seals have been removed.
The same evacuation procedure as for R12 systems must be used.
Max. 1% non-condensable gases.
The system must not contain any chlorine.
The charging equipment must only be used for R134a.
If the same vacuum pump is to be used for R12 and R134a systems, a special Ester oil must
be used in agreement with the pump supplier.
10. Warnings
July 2003
No high potential test nor start tests must be carried out while the compressor is under vacuum.
No attempt must be made to start the compressor without a complete starting device.
Allow the compressor to assume a temperature above 50F (10C) before starting the first
time in order to avoid starting problems.
Anti-freeze agents must not be used in the compressors as such agents are damaging to
several of the materials used. In particular, the ethyl or methyl alcohol contents of such antifreeze agents have a destructive effect on the synthetic motor insulation.
CK.40.A5.22
11
PL30F
Standard Compressor
R134a
100-115V 50/60Hz
Data Sheet (Replaces CD.41.J4.22)
General
PL30F
PL30F
Code number
101G
Application
101G9100
R134a
Blue stripe
9100
Application
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/HBP
Barcode on
white background
Green background
DANFOSS COMPRESSORS
90 - 127 /50,60
RSIR/CSIR
V/F (C)
at Voltage
V/F (C)
Comp. cooling at
max. ambient temperature
110F (43C)
100F (38C)
S
O
F1
F2
PL30F
115V-60Hz
1PH
THERMALLY
PROTECTED
8308-4
Motor type
8308-3
Approval mark
Design
cu.in. (cm3)
5.1 (150)
oz. (g)
10.5 (300)
fl.oz. (cm3)
28.9 (850)
0.09 (1.41)
fl.oz. (cm3)
lbs. (kg)
9.5 (4.3)
Motor
Motor size
watt
50
9.5/6.1
1.81" (46)
2.32"(59)
5.12"(130)
Oil quantity
1.97"(50)
2.38" (60.5)
Displacement
9.5/6.1
5.00"(127)
7.6/13.6
C
E
UL984/CSA-C22.2
Dimensions
5.28 (134)
5.20 (132)
B1
4.88 (124)
B2
2.87 (73)
Suction connector
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
pcs.
B1 B A
B2
8.11"(206)
8240
8.03"(204)
6.70"(170)
150
0.63"(16)
April 2003
12
CD.41.J5.22
CK.40.A5.22
2.76"(70)
3.94"(100)
in. (mm) A
1.38"
Height
(35)
Approvals
0.35"(9)
July 2003
-13
-25
89.1
-10
-23.3
103
0
-17.8
156
10
-12.2
221
Btu/h
20
-6.7
302
30
-1.1
399
40
4.4
517
45
7.2
584
50
10
657
30
-1.1
354
40
4.4
458
45
7.2
517
50
10
581
59
15
804
-13
-25
79.2
-10
-23.3
91.6
0
-17.8
139
10
-12.2
197
Btu/h
20
-6.7
268
59
15
711
-25
-13
21.0
-23.3
-10
24.3
-17.8
0
36.8
-12.2
10
52.3
-13
-25
49.7
-10
-23.3
50.8
-6.7
20
71.2
-1.1
30
94.2
4.4
40
122
7.2
45
137
10
50
154
-13
-25
1.07
-10
-23.3
1.07
-13
-25
1.79
-10
-23.3
2.03
0
-17.8
55.2
10
-12.2
60.5
20
-6.7
66.3
30
-1.1
72.4
40
4.4
78.5
45
7.2
81.4
50
10
84.2
-13
-25
1.59
-10
-23.3
1.80
59
15
88.9
0
-17.8
1.09
10
-12.2
1.11
20
-6.7
1.13
30
-1.1
1.16
40
4.4
1.19
45
7.2
1.20
50
10
1.22
-25
-13
0.42
-23.3
-10
0.48
0
-17.8
2.82
10
-12.2
3.66
0
-17.8
2.51
59
15
1.25
-17.8
0
0.67
Btu/Wh
20
-6.7
4.55
30
-1.1
5.51
40
4.4
6.58
45
7.2
7.17
50
10
7.79
10
-12.2
3.25
20
-6.7
4.04
30
-1.1
4.89
40
4.4
5.83
45
7.2
6.35
50
10
6.90
-12.2
10
0.86
-6.7
20
1.07
-1.1
30
1.30
4.4
40
1.55
7.2
45
1.69
10
50
1.83
59
15
9.04
Winding protector
Btu/Wh
a1
watt
8224
8224-2
15
59
189
Current consumption
Comp.\F
Comp.\C
PL30F
watt
Power consumption
Comp.\F
Comp.\C
PL30F
LST
59
15
7.99
W/W
Test conditions
ASHRAE (LBP) ASHRAE (HBP)
Condensing temperature
130F (54.4C) 130F (54.4C)
Ambient and suction gas temp. 90F (32C)
95F (35C)
Liquid temperature
90F (32C)
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
15
59
2.12
HST
c
b
8225
Accessories
a2
Devices
Fig.
PL30F
a1
103N0003
103N0023
a2
117U6000
Starting capacitor 80 F
117U5015
Cover
103N0492
Cord relief
103N1010
Starting relay
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CD.41.J5.22
CK.40.A5.22
11
10
12
13
14
Main winding
Winding protector
Start winding
April 2003
13
PL50F
Standard Compressor - LST Starting Characteristics
R134a
115V 60Hz
Data Sheet (Replaces CD.41.A6.22)
General
PL50F
PL50F
Codenumber
101G
Application
101G9200
R134a
Blue stripe
9200
Application
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/MBP
Barcode on
white background
-13 to 32 (-25 to 0)
Green background
DANFOSS COMPRESSORS
RSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
PL50F
115V-60Hz
1PH
THERMALLY
PROTECTED
8308-2
Motor type
8308
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
5.1 (150)
oz. (g)
10.5 (300)
fl.oz. (cm3)
28.9 (850)
0.12 (2.00)
lbs. (kg)
9.5 (4.3)
watt
50
4.9
14.0
8.8/5.5
Approvals
1.81" (46)
2.32"(59)
5.12"(130)
Motor size
1.97"(50)
2.38" (60.5)
Motor
5.00"(127)
UL984/CSA-C22.2
E
Dimensions
5.20 (132)
B1
4.88 (124)
B2
location/I.D. in. (mm) C
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
8.11"(206)
2.87 (73)
Suction connector
Compressors on a pallet
B1 B A
B2
8240
8.03"(204)
6.70"(170)
150
0.63"(16)
February 2003
14
CD.41.A7.22
CK.40.A5.22
2.76"(70)
3.94"(100)
5.28 (134)
(35)
in. (mm) A
1.38"
Height
0.35"(9)
July 2003
-13
-25
155
-10
-23.3
175
0
-17.8
249
Btu/h
10
-12.2
335
20
-6.7
437
30
-1.1
557
20
-6.7
388
30
-1.1
494
32
0
584
-13
-25
138
-10
-23.3
156
0
-17.8
221
10
-12.2
297
Btu/h
32
0
518
-25
-13
36.8
-23.3
-10
41.5
-17.8
0
58.9
-13
-25
62.3
-10
-23.3
65.0
-12.2
10
79.3
-6.7
20
103
-1.1
30
132
0
32
138
-13
-25
1.12
-10
-23.3
1.13
0
-17.8
73.2
10
-12.2
80.9
20
-6.7
88.5
30
-1.1
96.2
-13
-25
2.49
-10
-23.3
2.70
0
-17.8
1.18
10
-12.2
1.22
20
-6.7
1.27
32
0
97.8
30
-1.1
1.33
-13
-25
2.21
-10
-23.3
2.40
-25
-13
0.59
-23.3
-10
0.64
0
-17.8
3.39
10
-12.2
4.14
0
-17.8
3.02
32
0
1.34
20
-6.7
4.94
30
-1.1
5.79
10
-12.2
3.67
20
-6.7
4.38
30
-1.1
5.14
-12.2
10
0.98
-6.7
20
1.17
-1.1
30
1.37
32
0
5.97
Btu/Wh
Btu/Wh
a1
watt
Current consumption
Comp.\F
Comp.\C
PL50F
8224
8224-2
watt
Power consumption
Comp.\F
Comp.\C
PL50F
Winding protector
32
0
5.29
W/W
-17.8
0
0.80
Test conditions
ASHRAE (LBP) ASHRAE (MBP)
Condensing temperature
130F (54.4C) 130F (54.4C)
Ambient and suction gas temp. 90F (32C)
95F (35C)
Liquid temperature
90F (32C)
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
0
32
1.41
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
PTC star ting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades
PL50F
a1
103N0003
103N0023
Cover
103N0492
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Fig.
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CD.41.A7.22
CK.40.A5.22
February 2003
15
PL50F
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.41.I3.22)
General
PL50F
PL50F
Codenumber
101G
Application
101G9202
R134a
Blue stripe
9202
Application
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/MBP
Barcode on
white background
-13 to 32 (-25 to 0)
Green background
DANFOSS COMPRESSORS
RSIR/CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
PL50F
115V-60Hz
1PH
THERMALLY
PROTECTED
8308-2
Motor type
8308-5
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
5.1 (150)
oz. (g)
10.5 (300)
fl.oz. (cm3)
28.9 (850)
0.12 (2.00)
lbs. (kg)
9.5 (4.3)
watt
50
9.5/6.1
9.5/6.1
1.81" (46)
2.32"(59)
5.12"(130)
Motor size
1.97"(50)
2.38" (60.5)
Motor
7.6/13.6
Approvals
5.00"(127)
UL984/CSA-C22.2
E
Dimensions
5.20 (132)
B1
4.88 (124)
B2
location/I.D. in. (mm) C
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
8.11"(206)
2.87 (73)
Suction connector
Compressors on a pallet
B1 B A
B2
8240
8.03"(204)
6.70"(170)
150
0.63"(16)
February 2003
16
CD.41.I4.22
CK.40.A5.22
2.76"(70)
3.94"(100)
5.28 (134)
(35)
in. (mm) A
1.38"
Height
0.35"(9)
July 2003
-13
-25
155
-10
-23.3
175
0
-17.8
249
Btu/h
10
-12.2
335
20
-6.7
437
30
-1.1
557
20
-6.7
388
30
-1.1
494
32
0
584
-13
-25
138
-10
-23.3
156
0
-17.8
221
Btu/h
10
-12.2
297
32
0
518
-25
-13
36.8
-23.3
-10
41.5
-17.8
0
58.9
-13
-25
62.3
-10
-23.3
65.0
-12.2
10
79.3
-6.7
20
103
-1.1
30
132
-13
-25
1.12
-10
-23.3
1.13
-13
-25
2.49
-10
-23.3
2.70
0
-17.8
73.2
10
-12.2
80.9
20
-6.7
88.5
30
-1.1
96.2
-13
-25
2.21
-10
-23.3
2.40
32
0
97.8
0
-17.8
1.18
10
-12.2
1.22
20
-6.7
1.27
30
-1.1
1.33
-25
-13
0.59
-23.3
-10
0.64
0
-17.8
3.39
10
-12.2
4.14
0
-17.8
3.02
32
0
1.34
-17.8
0
0.80
Btu/Wh
20
-6.7
4.94
30
-1.1
5.79
10
-12.2
3.67
20
-6.7
4.38
30
-1.1
5.14
-12.2
10
0.98
-6.7
20
1.17
-1.1
30
1.37
Btu/Wh
Winding protector
32
0
5.29
W/W
Test conditions
ASHRAE (LBP) ASHRAE (MBP)
Condensing temperature
130F (54.4C) 130F (54.4C)
Ambient and suction gas temp. 90F (32C)
95F (35C)
Liquid temperature
90F (32C)
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
32
0
5.97
a1
watt
8224
8224-2
0
32
138
Current consumption
Comp.\F
Comp.\C
PL50F
watt
Power consumption
Comp.\F
Comp.\C
PL50F
LST
0
32
1.41
HST
c
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
b
8225
a2
Accessories
Fig.
PL50F
Devices
a1
103N0003
103N0023
a2
117U6000
117U5015
Cover
103N0492
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
c
11
10
12
13
14
118-1917
118-1918
118-1919
Main winding
Winding protector
CD.41.I4.22
CK.40.A5.22
Start winding
February 2003
17
TL2.5F
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.42.B5.22)
General
Compressor
Sealing
Code number
Copper-plated steel
Aluminium caps
102G3206
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
102G
TL2.5F
TL2.5F
Connector-material
Application
R134a
3206
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8310
Blue stripe
LBP/MBP
F (C)
Voltage range
V/Hz
Motor type
RSIR
F (C)
110 (43)
Comp. cooling at
S
O
F1
F2
110F (43C)
TL2.5F
115V-60Hz
1PH
8310-2
Application
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
4.02"(102)
5.3
14.5
Dimensions
Height
in. (mm) A
6.42 (163)
6.26 (159)
Suction connector
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
pcs.
125
A B
0.75"(19)
6.50"(165)
(29)
1.14"
0.63"(16)
2.76"(70)
UL984/CSA-C22.2
D
C
E
7.3/4.8
Approvals
or
8.74"(222)
6.93"(176)
31.5
28
C or
D
5.35"(136)
75
8261
4.13"(105)
4.21"(107)
watt
4.13"(105)
Motor size
3.78"(96)
4.61"(117)
30
Motor
2.80"(71)
14.7 (6.7)
4.00"(101.6)
54.2 (1600)
lbs. (kg)
6.18"(157)
fl.oz. (cm3)
51 20
45
2.38"(60.5)
2.60" (66)
0.16 (2.61)
0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)
June 2003
18
CD.42.B6.22
CK.40.A5.22
July 2003
-13
-25
181
-10
-23.3
202
0
-17.8
287
10
-12.2
396
Btu/h
20
-6.7
524
-13
-25
162
-10
-23.3
180
0
-17.8
255
10
-12.2
354
20
-6.7
466
23
-5
568
Btu/h
b
23
-5
506
8217-2
a1
-25
-13
43
-23.3
-10
48
-17.8
0
68
-12.2
10
93
watt
-6.7
20
124
-5
23
134
Power consumption
Comp.\F
Comp.\C
TL2.5F
-13
-25
61
-10
-23.3
65
watt
0
-17.8
77
10
-12.2
90
20
-6.7
104
23
-5
109
Current consumption
Comp.\F
Comp.\C
TL2.5F
-13
-25
0.91
-10
-23.3
0.94
-13
-25
2.96
-10
-23.3
3.11
10
-12.2
1.08
20
-6.7
1.22
0
-17.8
3.73
10
-12.2
4.42
-13
-25
2.63
-10
-23.3
2.77
0
-17.8
3.32
-25
-13
0.70
-23.3
-10
0.74
-17.8
0
0.88
23
-5
1.29
Winding protector
23
-5
5.22
Btu/Wh
10
-12.2
3.93
20
-6.7
4.49
-12.2
10
1.04
-6.7
20
1.19
23
-5
4.65
W/W
Accessories
-5
23
1.23
Test conditions
ASHRAE (LBP) ASHRAE (MBP)
Condensing temperature
130F (54.4C) 130F (54.4C)
Ambient and suction gas temp. 90F (32C)
95F (35C)
Liquid temperature
90F (32C)
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
Devices
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
July 2003
Fig.
TL2.5F
a1
103N0003
103N0023
Cover
103N2011
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
Btu/Wh
20
-6.7
5.05
A
0
-17.8
1.00
CD.42.B6.22
CK.40.A5.22
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
June 2003
19
TL3F
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.42.O1.22)
General
Sealing
Code number
Copper-plated steel
Aluminium caps
102G3300
Copper-plated steel
Rubber plugs
102G3307
Copper
Rubber plugs
102G
TL3F
TL3F
Connector-material
Application
R134a
Blue stripe
3300
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8310-3
Compressor
LBP/MBP
F (C)
Voltage range
V/Hz
Motor type
RSIR
F (C)
110 (43)
S
O
F1
Comp. cooling at
max. ambient temperature
110F (43C)
F2
TL3F
115V-60Hz
1PH
8310-4
Application
THERMALLY
PROTECTED
Approval mark
lbs. (kg)
14.7 (6.7)
4.02"(102)
6.0
15.0
Dimensions
in. (mm) A
6.42 (163)
6.26 (159)
Suction connector
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
pcs.
125
A B
0.75"(19)
6.50"(165)
D
C
0.63"(16)
2.76"(70)
UL984/CSA-C22.2
or
8.74"(222)
6.93"(176)
6.3/4.8
Approvals
Height
C or
D
4.13"(105)
4.21"(107)
90
8261
31.5
28
watt
4.13"(105)
Motor size
3.78"(96)
4.61"(117)
30
Motor
(29)
14.0 (400)
54.2 (1600)
5.35"(136)
oz. (g)
fl.oz. (cm3)
45
1.14"
2.80"(71)
6.1 (180)
4.00"(101.6)
0.19 (3.13)
fl.oz. (cm3)
51 20
cu.in. (cm3)
Oil quantity
6.18"(157)
Displacement
2.38"(60.5)
2.60" (66)
Design
0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
20
CG.42.O2.22
CK.40.A5.22
July 2003
-13
-25
228
-10
-23.3
253
0
-17.8
351
10
-12.2
478
Btu/h
20
-6.7
636
-13
-25
203
-10
-23.3
225
0
-17.8
312
10
-12.2
425
20
-6.7
566
23
-5
692
Btu/h
b
23
-5
616
8217-2
a1
-25
-13
54
-23.3
-10
60
-17.8
0
83
-12.2
10
113
watt
-6.7
20
150
-5
23
163
Power consumption
Comp.\F
Comp.\C
TL3F
-13
-25
72
-10
-23.3
77
watt
0
-17.8
92
10
-12.2
108
20
-6.7
125
23
-5
130
Current consumption
Comp.\F
Comp.\C
TL3F
-13
-25
1.09
-10
-23.3
1.12
-13
-25
3.15
-10
-23.3
3.29
10
-12.2
1.32
20
-6.7
1.47
0
-17.8
3.80
10
-12.2
4.42
-13
-25
2.80
-10
-23.3
2.93
0
-17.8
3.38
10
-12.2
3.93
-25
-13
0.75
-23.3
-10
0.78
-17.8
0
0.90
23
-5
1.52
23
-5
5.34
July 2003
Accessories
23
-5
4.75
Devices
PTC star ting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades
W/W
-12.2
10
1.04
-6.7
20
1.20
-5
23
1.26
Test conditions
ASHRAE (LBP) ASHRAE (MBP)
Condensing temperature
130F (54.4C) 130F (54.4C)
Ambient and suction gas temp. 90F (32C)
95F (35C)
Liquid temperature
90F (32C)
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
Winding protector
Btu/Wh
20
-6.7
4.55
Btu/Wh
20
-6.7
5.11
A
0
-17.8
1.21
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Fig.
TL3F
a1
103N0003
103N0023
Cover
103N2011
Cord relief
103N1010
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.42.O2.22
CK.40.A5.22
July 2003
21
TL4F
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.42.P1.22)
General
Sealing
Code number
Copper-plated steel
Aluminium caps
102G3400
Copper-plated steel
Rubber plugs
102G3402
Copper
Rubber plugs
102G
TL4F
TL4F
Connector-material
Application
R134a
Blue stripe
3400
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8310-5
Compressor
LBP/MBP
F (C)
Voltage range
V/Hz
Motor type
RSIR
F (C)
110 (43)
Comp. cooling at
S
O
F1
F2
110F (43C)
TL4F
115V-60Hz
1PH
8310-6
Application
THERMALLY
PROTECTED
Approval mark
lbs. (kg)
14.7 (6.7)
4.02"(102)
105
7.0
16.0
Dimensions
Height
in. (mm) A
6.42 (163)
6.26 (159)
Suction connector
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
pcs.
125
A B
0.75"(19)
6.50"(165)
0.63"(16)
2.76"(70)
UL984/CSA-C22.2
D
C
E
5.3/4.9
Approvals
or
8.74"(222)
6.93"(176)
31.5
28
C or
D
8261
4.13"(105)
4.21"(107)
watt
4.13"(105)
Motor size
3.78"(96)
4.61"(117)
30
Motor
(29)
14.0 (400)
54.2 (1600)
5.35"(136)
oz. (g)
fl.oz. (cm3)
45
1.14"
2.80"(71)
6.1 (180)
4.00"(101.6)
0.23 (3.86)
fl.oz. (cm3)
51 20
cu.in. (cm3)
Oil quantity
6.18"(157)
Displacement
2.38"(60.5)
2.60" (66)
Design
0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
22
CG.42.P2.22
CK.40.A5.22
July 2003
-30
-34.4
181
-20
-28.9
228
-13
-25
281
-10
-23.3
310
0
-17.8
430
Btu/h
10
-12.2
594
-30
-34.4
161
-20
-28.9
203
-13
-25
250
-10
-23.3
276
0
-17.8
383
20
-6.7
802
Btu/h
10
-12.2
529
20
-6.7
714
8217-2
a1
-34.4
-30
43
-28.9
-20
54
-25
-13
66
-23.3
-10
73
watt
-17.8
0
102
-12.2
10
141
-6.7
20
190
Power consumption
Comp.\F
Comp.\C
TL4F
-30
-34.4
64
-20
-28.9
77
watt
-13
-25
87
-10
-23.3
91
0
-17.8
107
10
-12.2
124
Current consumption
Comp.\F
Comp.\C
TL4F
-30
-34.4
1.36
-20
-28.9
1.43
-30
-34.4
2.81
-20
-28.9
2.97
-10
-23.3
1.52
0
-17.8
1.61
10
-12.2
1.72
-13
-25
3.25
-10
-23.3
3.41
0
-17.8
4.03
10
-12.2
4.79
-30
-34.4
2.50
-20
-28.9
2.64
-13
-25
2.89
-10
-23.3
3.03
0
-17.8
3.59
10
-12.2
4.26
-34.4
-30
0.66
-28.9
-20
0.70
-25
-13
0.77
July 2003
Winding protector
20
-6.7
5.64
Accessories
20
-6.7
5.02
Devices
PTC star ting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades
W/W
-23.3
-10
0.80
-17.8
0
0.95
-12.2
10
1.13
Test conditions
ASHRAE (LBP) ASHRAE (MBP)
Condensing temperature
130F (54.4C) 130F (54.4C)
Ambient and suction gas temp. 90F (32C)
95F (35C)
Liquid temperature
90F (32C)
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
20
-6.7
1.84
Btu/Wh
Btu/Wh
A
-13
-25
1.49
20
-6.7
142
-6.7
20
1.33
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Fig.
TL4F
a1
103N0003
103N0023
Cover
103N2011
Cord relief
103N1010
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.42.P2.22
CK.40.A5.22
July 2003
23
TLS4.5F
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.42.D4.22)
General
TLS4.5F
102G3420
102G3421
Application
R134a
SUCTION
CONNECTOR
Blue stripe
Application
102G
TLS4.5F
3420
Barcode on
white background
Application
LBP
-31 to 23 (-35 to -5)
F (C)
Voltage range
Green background
V/Hz
Motor type
TLS4.5F
115V-60Hz
1PH
RSIR/CSIR
F (C)
110 (43)
S
O
F1
Comp. cooling at
max. ambient temperature
110F (43C)
F2
THERMALLY
PROTECTED
8311-2
DANFOSS COMPRESSORS
8311
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
fl.oz. (cm3)
170
12.2/14.2
22.6/14.2
4.02"(102)
Process connector
0.35"(9)
Discharge connector
(29)
1.14"
4.13"(105)
6.50"(165)
(35)
1.38"
125
0.75"(19)
4.21"(107)
30
Suction connector
0.63"(16)
2.76"(70)
6.26 (159)
4.13"(105)
6.42 (163)
2.76"(70)
in. (mm) A
31.5
28
A B
Dimensions
pcs.
2.80"(71)
UL984/CSA-C22.2
Compressors on a pallet
8.74"(222)
6.93"(176)
3.2/3.4
Approvals
Height
8403
3.78"(96)
4.61"(117)
3.94"(100)
5.35"(136)
watt
4.00"(101.6)
Motor size
45
Motor
14.7 (6.7)
20
60.7 (1790)
lbs. (kg)
51
6.18"(157)
2.38"(60.5)
2.60" (66)
0.29 (4.63)
0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)
June 2003
24
CD.42.D5.22
CK.40.A5.22
July 2003
-30
-34.4
245
-20
-28.9
340
-13
-25
431
-10
-23.3
477
Btu/h
0
-17.8
654
10
-12.2
875
20
-6.7
1135
-17.8
0
155
-12.2
10
208
-6.7
20
269
23
-5
1225
-34.4
-30
58
-28.9
-20
80
-25
-13
102
LST
watt
-23.3
-10
113
-5
23
290
b
8217-2
a1
Power consumption
Comp.\F
Comp.\C
TLS4.5F
-30
-34.4
92
watt
-20
-28.9
110
-13
-25
123
-10
-23.3
129
0
-17.8
150
10
-12.2
174
20
-6.7
199
23
-5
207
Current consumption
Comp.\F
Comp.\C
TLS4.5F
-30
-34.4
1.87
-20
-28.9
1.93
A
-13
-25
1.99
-10
-23.3
2.02
0
-17.8
2.13
10
-12.2
2.27
20
-6.7
2.41
-30
-34.4
2.66
-20
-28.9
3.10
-13
-25
3.50
23
-5
2.46
-34.4
-30
0.63
-28.9
-20
0.73
-25
-13
0.83
Btu/Wh
-10
-23.3
3.69
0
-17.8
4.34
10
-12.2
5.03
20
-6.7
5.71
-23.3
-10
0.87
-17.8
0
1.03
-12.2
10
1.19
-6.7
20
1.35
23
-5
5.91
Winding protector
W/W
Test conditions
ASHRAE
Condensing temperature
130F (54,4C)
Ambient and suction gas temp.
90F (32C)
Liquid temperature
90F (32C)
Static cooling, 115V 60Hz, PTC consumption incl.
-5
23
1.40
HST
c
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
b
8219
a2
Accessories
Devices
Fig.
TLS4.5F
d
a1
103N0003
103N0023
a2
117U6003
117U5023
Cover
103N2011
Cord relief
103N1010
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
12
CK.40.A5.22
13
14
Main winding
CD.42.D5.22
11
10
June 2003
25
TF3F
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.42.C4.22)
General
TF3F
102G
TF3F
Application
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
102G3303
Blue stripe
Copper
Rubber plugs
102G3301
Barcode on
white background
R134a
3303
8327-3
Compressor
DANFOSS COMPRESSORS
Green background
Application
Application
LBP
S
O
F1
RSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
0.19 (3.13)
fl.oz. (cm3)
4.02"(102)
54.2 (1600)
lbs. (kg)
45
Displacement
6.18"(157)
Design
C or
D
14.7 (6.7)
3.78"(96)
4.61"(117)
(29)
95 - 135 /60
1.14"
V/Hz
Motor type
2.80"(71)
Voltage range
51 20
F (C)
2.34"(59.5)
2.60" (66)
8370
or
8.90"(226)
6.93"(176)
Motor
15.7
A B
5.1/10.0
-
0.75"(19)
Height
in. (mm) A
6.42 (163)
6.26 (159)
0.14"(3.6)
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
26
102G3301
pcs.
125
CD.42.C5.22
CK.40.A5.22
5.35"(136)
102G3303
0.63"(16)
2.76"(70)
Dimensions
6.50"(165)
4.00"(101.6)
Approvals
4.13"(105)
4.21"(107)
15.7
30
100
4.13"(105)
watt
31.5
28
Motor size
July 2003
D
C
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TF3F
-30
-34.4
69.9
Btu/h
-20
-28.9
148
-13
-25
210
-10
-23.3
239
0
-17.8
348
10
-12.2
478
14
-10
538
a2
-34.4
-30
16.1
-28.9
-20
34.7
watt
-25
-13
49.5
-23.3
-10
56.4
-17.8
0
82.2
-12.2
10
113
-13
-25
71.0
-10
-23.3
76.5
0
-17.8
93.6
10
-12.2
109
-10
14
127
Power consumption
Comp.\F
Comp.\C
TF3F
-30
-34.4
37.0
-20
-28.9
57.7
-30
-34.4
1.10
8230
watt
14
-10
116
Current consumption
Comp.\F
Comp.\C
TF3F
a2
-20
-28.9
1.20
-13
-25
1.28
-10
-23.3
1.31
0
-17.8
1.43
10
-12.2
1.54
14
-10
1.59
10
12
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TF3F
-30
-34.4
1.89
-34.4
-30
0.44
Start winding
Thermostat
14
Btu/Wh
-20
-28.9
2.56
-13
-25
2.96
-10
-23.3
3.13
0
-17.8
3.72
10
-12.2
4.37
14
-10
4.65
-23.3
-10
0.74
-17.8
0
0.88
-12.2
10
1.03
-10
14
1.10
11
13
-28.9
-20
0.61
W/W
-25
-13
0.70
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 115V 60Hz
Motor protector
ASHRAE
130F (54,4C)
90F (32C)
90F (32C)
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
Texas Instr.
MRP61GL-6
Cover
117U1021
Cord relief
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
July 2003
a2
TF3F
117U4100
CD.42.C5.22
CK.40.A5.22
July 2003
27
TF3.5F
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.42.Q1.22)
General
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
102G3304
Copper
Rubber plugs
102G3302
102G
TF3.5F
TF3.5F
Connector-material
Application
Code number
R134a
Blue stripe
3304
Barcode on
white background
8327
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
F (C)
V/Hz
95 - 135 /60
Motor type
S
O
F1
RSIR
F (C)
110 (43)
Comp. cooling at
F2
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
0.22 (3.59)
fl.oz. (cm3)
4.02"(102)
60.6 (1790)
lbs. (kg)
C or
D
16.5 (7.5)
3.78"(96)
4.61"(117)
(29)
Oil quantity
1.14"
cu.in. (cm3)
45
Displacement
Approval mark
Design
THERMALLY
PROTECTED
2.80"(71)
110F (43C)
6.18"(157)
TF3.5F
115V-60Hz
1PH
51 20
2.34"(59.5)
2.60" (66)
8327-2
Application
8370
or
8.90"(226)
6.93"(176)
D
C
E
watt
135
18.9
A B
18.9
4.13"(105)
4.21"(107)
Motor size
4.13"(105)
30
31.5
28
Motor
3.8/7.8
Approvals
UL984/CSA-C22.2
0.75"(19)
6.50"(165)
0.63"(16)
in. (mm) A
B
6.65 (169)
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
July 2003
28
6.81 (173)
5.35"(136)
Height
102G3302
2.76"(70)
102G3304
4.00"(101.6)
0.14"(3.6)
Dimensions
pcs.
6.70"(170)
7.01"(178)
8.03"(204)
125
CG.42.Q2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TF3.5F
-30
-34.4
133
Btu/h
-20
-28.9
205
-13
-25
270
-10
-23.3
303
0
-17.8
426
10
-12.2
581
14
-10
651
a2
-34.4
-30
32
-28.9
-20
49
watt
-25
-13
64
-23.3
-10
72
-17.8
0
101
-12.2
10
138
-13
-25
89
-10
-23.3
93
0
-17.8
108
10
-12.2
123
-10
14
155
Power consumption
Comp.\F
Comp.\C
TF3.5F
-30
-34.4
66
-30
-34.4
1.55
8230
watt
-20
-28.9
79
14
-10
129
Current consumption
Comp.\F
Comp.\C
TF3.5F
a2
-20
-28.9
1.60
-13
-25
1.64
-10
-23.3
1.66
0
-17.8
1.73
10
-12.2
1.82
14
-10
1.86
10
12
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TF3.5F
-30
-34.4
2.03
-34.4
-30
0.48
Start winding
Thermostat
14
Btu/Wh
-20
-28.9
2.59
-13
-25
3.04
-10
-23.3
3.25
0
-17.8
3.96
10
-12.2
4.73
14
-10
5.03
-23.3
-10
0.77
-17.8
0
0.94
-12.2
10
1.12
-10
14
1.20
11
13
-28.9
-20
0.62
W/W
-25
-13
0.72
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 115V 60Hz
Motor protector
ASHRAE
130F (54,4C)
90F (32C)
90F (32C)
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
Texas Instr.
Protector 3/4"
Electrica
a2
MRP57JK-6
T 0727/06
Cover
117U1021
Cord relief
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
July 2003
TF3.5F
117U4122
CG.42.Q2.22
CK.40.A5.22
July 2003
29
TFS4F
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.42.A4.22)
General
TFS4F
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
102G3431
Copper
Rubber plugs
102G3430
102G
TFS4F
Application
Code number
R134a
SUCTION
CONNECTOR
Blue stripe
3431
Barcode on
white background
8326
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
F (C)
V/Hz
95 - 135 /60
Motor type
S
O
F1
RSIR
F (C)
110 (43)
Comp. cooling at
F2
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
0.23 (3.86)
fl.oz. (cm3)
4.02"(102)
60.6 (1790)
lbs. (kg)
16.5 (7.5)
3.78"(96)
4.61"(117)
(29)
Oil quantity
1.14"
cu.in. (cm3)
45
Displacement
Approval mark
Design
THERMALLY
PROTECTED
2.80"(71)
110F (43C)
6.18"(157)
TFS4F
115V-60Hz
1PH
51 20
2.34"(59.5)
2.60" (66)
8326-2
Application
8246
8.90"(226)
6.93"(176)
E
watt
135
18.9
A B
18.9
4.13"(105)
4.21"(107)
Motor size
4.13"(105)
30
31.5
28
Motor
3.8/7.8
Approvals
UL984/CSA-C22.2
0.75"(19)
6.50"(165)
0.63"(16)
in. (mm) A
B
6.65 (169)
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
July 2003
30
6.81 (173)
5.35"(136)
Height
102G3430
2.76"(70)
102G3431
4.00"(101.6)
0.14"(3.6)
Dimensions
pcs.
6.70"(170)
7.01"(178)
8.03"(204)
125
CD.42.A5.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TFS4F
-30
-34.4
155
Btu/h
-20
-28.9
237
-13
-25
315
-10
-23.3
355
0
-17.8
506
10
-12.2
697
14
-10
782
a2
-34.4
-30
37
-28.9
-20
56
watt
-25
-13
75
-23.3
-10
85
-17.8
0
120
-12.2
10
166
-13
-25
92
-10
-23.3
97
0
-17.8
114
10
-12.2
132
-10
14
186
Power consumption
Comp.\F
Comp.\C
TFS4F
-30
-34.4
60
-30
-34.4
1.46
8230
watt
-20
-28.9
79
14
-10
139
Current consumption
Comp.\F
Comp.\C
TFS4F
a2
-20
-28.9
1.53
-13
-25
1.59
-10
-23.3
1.62
0
-17.8
1.71
10
-12.2
1.82
14
-10
1.87
10
12
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TFS4F
-30
-34.4
2.58
-34.4
-30
0.61
Start winding
Thermostat
14
Btu/Wh
-20
-28.9
3.00
-13
-25
3.44
-10
-23.3
3.66
0
-17.8
4.43
10
-12.2
5.28
14
-10
5.62
-23.3
-10
0.87
-17.8
0
1.05
-12.2
10
1.26
-10
14
1.34
11
13
-28.9
-20
0.71
W/W
-25
-13
0.82
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 115V 60Hz
Motor protector
ASHRAE
130F (54,4C)
90F (32C)
90F (32C)
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
Texas Instr.
Protector 3/4"
Electrica
a2
MRP57JK-6
T 0727/06
Cover
117U1021
Cord relief
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
July 2003
TFS4F
117U4122
CD.42.A5.22
CK.40.A5.22
July 2003
31
TT2.5F
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.42.Q5.22)
General
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
102G
TT2.5F
TT2.5F
Connector-material
Application
Code number
R134a
Blue stripe
102G3248
3248
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8325
Compressor
MBP
F (C)
Voltage range
V/Hz
Motor type
RSIR
F (C)
110 (43)
Comp. cooling at
S
O
F1
F2
110F (43C)
TT2.5F
115V-60Hz
1PH
8325-2
Application
THERMALLY
PROTECTED
Approval mark
fl.oz. (cm3)
54.2 (1600)
lbs. (kg)
14.7 (6.7)
4.02"(102)
C or
D
3.78"(96)
(29)
14.0 (400)
2.80"(71)
6.1 (180)
oz. (g)
0.16 (2.61)
1.14"
fl.oz. (cm3)
51 20
Oil quantity
6.18"(157)
cu.in. (cm3)
45
Displacement
2.34"(59.5)
2.60" (66)
Design
8530
or
8.90"(226)
6.93"(176)
Motor
E
A
5.1
14.0
8.1/4.9
Approvals
A B
4.06"(103)
4.72"(120)
30
65
4.06"(103)
watt
UL984/CSA-C22.2
0.75"(19)
Dimensions
6.50"(165)
0.63"(16)
5.98 (152)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
0.189-0.193 (4.9+0.10/-0)
125
CD.42.Q6.22
CK.40.A5.22
5.35"(136)
6.22 (158)
2.76"(70)
in. (mm) A
4.00"(101.6)
0.14"(3.6)
Height
32
31.5
Motor size
July 2003
D
C
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TT2.5F
-13
-25
166
Btu/h
-10
-23.3
187
0
-17.8
268
10
-12.2
373
20
-6.7
496
23
-5
539
-12.2
10
98
-6.7
20
132
-5
23
143
-25
-13
44
-23.3
-10
50
watt
-17.8
0
71
Power consumption
Comp.\F
Comp.\C
TT2.5F
-13
-25
66
-13
-25
0.96
-10
-23.3
69
0
-17.8
81
10
-12.2
93
20
-6.7
107
23
-5
112
-10
-23.3
0.99
0
-17.8
1.04
10
-12.2
1.11
20
-6.7
1.22
1
2
4
3
23
-5
1.28
-13
-25
2.54
-10
-23.3
2.69
0
-17.8
3.31
10
-12.2
3.99
20
-6.7
4.64
-17.8
0
0.88
-12.2
10
1.05
-6.7
20
1.23
23
-5
4.83
-25
-13
0.68
-23.3
-10
0.72
W/W
Test conditions
ASHRAE (MBP)
Condensing temperature
130F (54.4C)
Ambient and suction gas temp.
90F (32C)
Liquid temperature
115F (46C)
Static cooling, 115V 60Hz, PTC consumption incl.
a1
Start winding
Btu/Wh
EER (ASHRAE)
Comp.\F
Comp.\C
TT2.5F
a1
watt
Current consumption
Comp.\F
Comp.\C
TT2.5F
8234
Main winding
Motor protector
-5
23
1.28
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
TT2.5F
117U6102
TI 8EA 4B3
117U6105
a1
(alternative)
J506-A120-A120
Cover
117U1026
Mounting accessories
Bolt joint in one compressor
Bolt joint in one compressor
Snap-on in one compressor
July 2003
Fig.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
117U3301
TI-4TM276NFBYY-53
118-1946
118-1949
118-1947
CD.42.Q6.22
CK.40.A5.22
July 2003
33
NF6FK
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.43.T2.22)
General
NF6FK
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
105G5636
Copper-plated steel
Rubber plugs
105G5628
Copper
Rubber plugs
Application
105G
NF6FK
Blue stripe
R134a
SUCTION
CONNECTOR
5628
Barcode on
white background
8398
Compressor
DANFOSS COMPRESSORS
Green background
R
Application
S
O
F1
LBP/MBP
F (C)
Voltage range
V/Hz
95 - 135 /60
Motor type
F2
RSIR/CSIR*
F (C)
NF6FK
115V-60Hz
1PH
8398-2
Application
THERMALLY
PROTECTED
110 (43)
Approval mark
Displacement
cu.in. (cm3)
0.37 (6.13)
fl.oz. (cm3)
10.8 (320)
Oil quantity
Maximum refrigerant charge
Free gas vol. in compressor housing
23.0 (10.5)
A B
29.4
29.4
2.0/9.1
Approvals
9.92"(252)
8.03"(204)
6.70"(170)
UL984/CSA-C22.2
Dimensions
105G5628
Height
in. (mm) A
B
location/I.D. in. (mm) C
1.38"(35)
255
5.20"(132)
4.00"(101.6)
2.76"(70)
watt
4.04"(102.5)
3.68"(93.5)
lbs. (kg)
15
79.7 (2360)
105G5636
8.00 (203)
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
0.242-0.249 (6.20.09)
0.252-0.259 (6.50.09)
0.242-0.249 (6.20.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
July 2003
8367
7.76 (197)
0.320-0.327 (8.20.09)
Process connector
Compressors on a pallet
E
C
14.0 (400)
fl.oz. (cm3)
Motor size
34
8.10"(205)
Motor
Suction connector
4.69"(119)
5.00"(127)
35
oz. (g)
4.45"(113)
47
2.97"(75.5)
Design
27
51
(54)
2.13"
S
F1
3.01"(78)
100F (38C)
110F (43C)
25
6.54"(166)
2.83"(72)
2.34" (59.5)
Comp. cooling at
pcs.
80
CG.43.T3.22
CK.40.A5.22
July 2003
-20
-28.9
462
-13
-25
602
-10
-23.3
66 8
0
-17.8
91 2
Btu/h
10
-12.2
1206
20
-6.7
1560
30
-1.1
1982
40
4.4
2484
10
-12.2
1071
20
-6.7
138 4
30
-1.1
1758
40
4.4
2202
45
7.2
2768
-20
-28.9
411
-13
-25
535
-10
-23.3
59 3
0
-17.8
81 1
45
7.2
2452
-28.9
-20
109
-20
-28.9
138
-25
-13
143
-23.3
-10
158
-17.8
0
21 6
-12.2
10
286
-6.7
20
369
-1.1
30
46 8
4.4
40
586
-20
-28.9
2.49
-13
-25
162
-10
-23.3
172
0
-17.8
204
10
-12.2
232
20
-6.7
25 9
30
-1.1
285
40
4.4
310
45
7.2
323
-13
-25
2.60
-10
-23.3
2.65
0
-17.8
2.82
10
-12.2
3.00
20
-6.7
3.19
30
-1.1
3.39
40
4.4
3.59
45
7.2
3.69
-20
-28.9
3.35
-20
-28.9
2.98
-13
-25
3.71
-13
-25
3.30
-28.9
-20
0.79
-25
-13
0.88
10
12
11
13
Start winding
Thermostat
Main winding
14
Btu/Wh
-10
-23.3
3.87
0
-17.8
4.48
10
-12.2
5.19
20
-6.7
6.01
30
-1.1
6.95
40
4.4
8.00
-10
-23.3
3.44
0
-17.8
3.98
10
-12.2
4.61
20
-6.7
5.34
30
-1.1
6.16
40
4.4
7.09
-23.3
-10
0.92
-17.8
0
1.06
-12.2
10
1.23
-6.7
20
1.42
-1.1
30
1.64
4.4
40
1.88
45
7.2
8.57
Btu/Wh
a2
watt
8230
7.2
45
653
Current consumption
Comp.\F -30
Comp.\C -34.4
NF6FK
2.33
watt
Power consumption
Comp.\F -30
Comp.\C -34.4
NF6FK
100
a2
Btu/h
Motor protector
(pos.1)
45
7.2
7.59
W/W
7.2
45
2.01
c
a2
Accessories
Devices
Star ting relay (protector incl.)
Protector 3/4" Texas Instruments
Star ting relay (protector incl.)
Star ting capacitor 320 F
Protector 3/4" Texas Instruments
NF6FK
a2
(pos.1)
MRT30AEZ-6
a2
c
(pos.2)
117U4131
117U4132*
117U5022*
MRT30AEZ-6
Cover
117U1021
Cord relief
117U0317
dc
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
8226
Fig.
Test conditions
1. Condensing temperature
2. Ambient & suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
dc
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. MBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
1.
55C (131F)
2.
32C (90F)
3.
55C (131F)
b
a2
c
10
12
Main winding
11
13
Start winding
Thermostat
14
(pos.2)
Motor protector
CG.43.T3.22
CK.40.A5.22
July 2003
35
NF7FK
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.43.U2.22)
General
NF7FK
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
105G5736
Copper-plated steel
Rubber plugs
105G5728
Copper
Rubber plugs
Application
105G
NF7FK
Blue stripe
R134a
SUCTION
CONNECTOR
5728
Barcode on
white background
8398-3
Compressor
DANFOSS COMPRESSORS
Green background
R
Application
S
O
F1
LBP/MBP
F (C)
Voltage range
V/Hz
95 - 135 /60
Motor type
F2
RSIR/CSIR*
F (C)
NF7FK
115V-60Hz
1PH
8398-4
Application
THERMALLY
PROTECTED
110 (43)
Approval mark
Displacement
cu.in. (cm3)
0.44 (7.27)
Oil quantity
fl.oz. (cm3)
10.8 (320)
23.0 (10.5)
A B
29.4
29.4
2.0/9.1
Approvals
9.92"(252)
8.03"(204)
6.70"(170)
UL984/CSA-C22.2
Dimensions
105G5728
Height
in. (mm) A
B
location/I.D. in. (mm) C
1.38"(35)
255
5.20"(132)
4.00"(101.6)
2.76"(70)
watt
4.04"(102.5)
3.68"(93.5)
lbs. (kg)
15
79.7 (2360)
105G5736
8.00 (203)
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
0.242-0.249 (6.20.09)
0.252-0.259 (6.50.09)
0.242-0.249 (6.20.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
July 2003
8367
7.76 (197)
0.320-0.327 (8.20.09)
Process connector
Compressors on a pallet
E
C
14.0 (400)
fl.oz. (cm3)
Motor size
36
8.10"(205)
Motor
Suction connector
4.69"(119)
5.00"(127)
35
oz. (g)
4.45"(113)
47
2.97"(75.5)
Design
27
51
(54)
2.13"
S
F1
3.01"(78)
100F (38C)
110F (43C)
25
6.54"(166)
2.83"(72)
2.34" (59.5)
Comp. cooling at
pcs.
80
CG.43.U3.22
CK.40.A5.22
July 2003
-20
-28.9
600
-13
-25
758
-10
-23.3
833
0
-17.8
1112
Btu/h
10
-12.2
1451
20
-6.7
1861
30
-1.1
235 5
40
4.4
294 6
10
-12.2
1288
20
-6.7
1651
30
-1.1
2089
40
4.4
2611
45
7.2
3282
-20
-28.9
533
-13
-25
674
-10
-23.3
740
0
-17.8
988
45
7.2
2907
-28.9
-20
142
-20
-28.9
168
-25
-13
180
-23.3
-10
198
-17.8
0
264
-12.2
10
344
-6.7
20
44 1
-1.1
30
55 7
4.4
40
696
-20
-28.9
2.69
-13
-25
193
-10
-23.3
204
0
-17.8
23 8
10
-12.2
271
20
-6.7
30 3
30
-1.1
336
40
4.4
369
45
7.2
385
-13
-25
2.81
-10
-23.3
2.87
0
-17.8
3.05
10
-12.2
3.25
20
-6.7
3.45
30
-1.1
3.66
40
4.4
3.88
45
7.2
4.00
-20
-28.9
3.57
-20
-28.9
3.18
-13
-25
3.93
-13
-25
3.49
-28.9
-20
0.84
-25
-13
0.93
10
12
11
13
Start winding
Thermostat
Main winding
14
Btu/Wh
-10
-23.3
4.09
0
-17.8
4.68
10
-12.2
5.35
20
-6.7
6.13
30
-1.1
7.01
40
4.4
7.99
-10
-23.3
3.64
0
-17.8
4.16
10
-12.2
4.76
20
-6.7
5.44
30
-1.1
6.22
40
4.4
7.08
-23.3
-10
0.97
-17.8
0
1.11
-12.2
10
1.26
-6.7
20
1.45
-1.1
30
1.65
4.4
40
1.88
45
7.2
8.52
Btu/Wh
a2
watt
8230
7.2
45
775
Current consumption
Comp.\F -30
Comp.\C -34.4
NF7FK
2.52
watt
Power consumption
Comp.\F -30
Comp.\C -34.4
NF7FK
130
a2
Btu/h
Motor protector
(pos.1)
45
7.2
7.55
W/W
7.2
45
2.00
c
a2
Accessories
Devices
Star ting relay (protector incl.)
Protector 3/4" Texas Instruments
Star ting relay (protector incl.)
Star ting capacitor 320 F
Protector 3/4" Texas Instruments
NF7FK
a2
(pos.1)
MRT30AEZ-6
a2
c
(pos.2)
117U4131
117U4132*
117U5022*
MRT30AEZ-6
Cover
117U1021
Cord relief
117U0317
dc
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
8226
Fig.
Test conditions
1. Condensing temperature
2. Ambient & suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
dc
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. MBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
1.
55C (131F)
2.
32C (90F)
3.
55C (131F)
b
a2
c
10
12
Main winding
11
13
Start winding
Thermostat
14
(pos.2)
Motor protector
CG.43.U3.22
CK.40.A5.22
July 2003
37
NF9FK
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.43.V2.22)
General
NF9FK
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
105G5936
Copper-plated steel
Rubber plugs
105G5928
Copper
Rubber plugs
Application
105G
NF9FK
Blue stripe
R134a
SUCTION
CONNECTOR
5928
Barcode on
white background
8398-5
Compressor
DANFOSS COMPRESSORS
Green background
R
Application
S
O
F1
LBP/MBP
F (C)
Voltage range
V/Hz
95 - 135 /60
Motor type
F2
RSIR/CSIR*
F (C)
NF9FK
115V-60Hz
1PH
8398-6
Application
THERMALLY
PROTECTED
110 (43)
Approval mark
Displacement
cu.in. (cm3)
0.51 (8.35)
Oil quantity
fl.oz. (cm3)
10.8 (320)
23.0 (10.5)
A B
34.0
34.0
2.0/7.5
Approvals
9.92"(252)
8.03"(204)
6.70"(170)
UL984/CSA-C22.2
Dimensions
105G5928
Height
in. (mm) A
B
location/I.D. in. (mm) C
1.38"(35)
290
5.20"(132)
4.00"(101.6)
2.76"(70)
watt
4.04"(102.5)
3.68"(93.5)
lbs. (kg)
15
79.7 (2360)
105G5936
8.00 (203)
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
0.242-0.249 (6.20.09)
0.252-0.259 (6.50.09)
0.242-0.249 (6.20.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
July 2003
8367
7.76 (197)
0.320-0.327 (8.20.09)
Process connector
Compressors on a pallet
E
C
14.0 (400)
fl.oz. (cm3)
Motor size
38
8.10"(205)
Motor
Suction connector
4.69"(119)
5.00"(127)
35
oz. (g)
4.45"(113)
47
2.97"(75.5)
Design
27
51
(54)
2.13"
F2
F2
3.01"(78)
100F (38C)
110F (43C)
25
6.54"(166)
2.83"(72)
2.34" (59.5)
Comp. cooling at
pcs.
80
CG.43.V3.22
CK.40.A5.22
July 2003
-20
-28.9
672
-13
-25
842
-10
-23.3
923
0
-17.8
1236
Btu/h
10
-12.2
1621
20
-6.7
208 7
30
-1.1
2647
40
4.4
330 8
10
-12.2
1439
20
-6.7
1853
30
-1.1
2348
40
4.4
2932
45
7.2
3681
-20
-28.9
598
-13
-25
748
-10
-23.3
820
0
-17.8
1098
45
7.2
3261
-28.9
-20
160
-20
-28.9
200
-25
-13
200
-23.3
-10
21 9
-17.8
0
293
-12.2
10
384
-6.7
20
495
-1.1
30
62 6
4.4
40
78 2
-20
-28.9
3.16
-13
-25
223
-10
-23.3
233
0
-17.8
267
10
-12.2
302
20
-6.7
33 9
30
-1.1
37 9
40
4.4
423
45
7.2
447
-13
-25
3.27
-10
-23.3
3.32
0
-17.8
3.51
10
-12.2
3.72
20
-6.7
3.96
30
-1.1
4.22
40
4.4
4.51
45
7.2
4.66
-20
-28.9
3.36
-20
-28.9
2.99
-13
-25
3.77
-13
-25
3.35
-28.9
-20
0.80
-25
-13
0.89
10
12
11
13
Start winding
Thermostat
Main winding
14
Btu/Wh
-10
-23.3
3.96
0
-17.8
4.63
10
-12.2
5.37
20
-6.7
6.16
30
-1.1
6.98
40
4.4
7.81
-10
-23.3
3.52
0
-17.8
4.12
10
-12.2
4.77
20
-6.7
5.47
30
-1.1
6.19
40
4.4
6.93
-23.3
-10
0.94
-17.8
0
1.10
-12.2
10
1.27
-6.7
20
1.46
-1.1
30
1.65
4.4
40
1.84
45
7.2
8.23
Btu/Wh
a2
watt
8230
7.2
45
870
Current consumption
Comp.\F -30
Comp.\C -34.4
NF9FK
3.02
watt
Power consumption
Comp.\F -30
Comp.\C -34.4
NF9FK
167
a2
Btu/h
Motor protector
(pos.1)
45
7.2
7.29
W/W
7.2
45
1.94
c
a2
Accessories
Devices
Star ting relay (protector incl.)
Protector 3/4" Texas Instruments
Star ting relay (protector incl.)
Star ting capacitor 320 F
Protector 3/4" Texas Instruments
NF9FK
a2
(pos.1)
MRT26AFZ-6
a2
c
(pos.2)
117U4133
117U4134*
117U5022*
MRT30AEZ-6
Cover
117U1021
Cord relief
117U0317
dc
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
8226
Fig.
Test conditions
1. Condensing temperature
2. Ambient & suction gas temp.
3. Liquid temperature
Fan cooling F2, 115V 60Hz
dc
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. MBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
1.
55C (131F)
2.
32C (90F)
3.
55C (131F)
b
a2
c
10
12
Main winding
11
13
Start winding
Thermostat
14
(pos.2)
Motor protector
CG.43.V3.22
CK.40.A5.22
July 2003
39
NF9.5FK
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.43.W2.22)
General
NF9.5FK
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
105G5937
Copper-plated steel
Rubber plugs
105G5929
Copper
Rubber plugs
Application
105G
NF9.5FK
Blue stripe
R134a
SUCTION
CONNECTOR
5929
Barcode on
white background
8398-7
Compressor
DANFOSS COMPRESSORS
Green background
R
Application
S
O
F1
LBP/MBP
F (C)
Voltage range
V/Hz
95 - 135 /60
Motor type
F2
NF9.5FK
115V-60Hz
1PH
THERMALLY
PROTECTED
RSIR/CSIR*
F (C)
8398-8
Application
110 (43)
Approval mark
Displacement
cu.in. (cm3)
0.57 (9.40)
Oil quantity
fl.oz. (cm3)
10.8 (320)
23.0 (10.5)
A B
35.5
35.5
1.4/7.6
Approvals
9.92"(252)
8.03"(204)
6.70"(170)
UL984/CSA-C22.2
Dimensions
105G5929
Height
in. (mm) A
B
location/I.D. in. (mm) C
1.38"(35)
360
5.20"(132)
4.00"(101.6)
2.76"(70)
watt
4.04"(102.5)
3.68"(93.5)
lbs. (kg)
15
79.7 (2360)
105G5937
8.00 (203)
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
0.242-0.249 (6.20.09)
0.252-0.259 (6.50.09)
0.242-0.249 (6.20.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
July 2003
8367
7.76 (197)
0.320-0.327 (8.20.09)
Process connector
Compressors on a pallet
E
C
14.0 (400)
fl.oz. (cm3)
Motor size
40
8.10"(205)
Motor
Suction connector
4.69"(119)
5.00"(127)
35
oz. (g)
4.45"(113)
47
2.97"(75.5)
Design
27
51
(54)
2.13"
F2
F2
3.01"(78)
100F (38C)
110F (43C)
25
6.54"(166)
2.83"(72)
2.34" (59.5)
Comp. cooling at
pcs.
80
CG.43.W3.22
CK.40.A5.22
July 2003
-20
-28.9
750
-13
-25
935
-10
-23.3
1024
0
-17.8
1366
Btu/h
10
-12.2
1787
20
-6.7
229 8
30
-1.1
2909
40
4.4
3633
10
-12.2
1587
20
-6.7
203 9
30
-1.1
2580
40
4.4
3220
45
7.2
4041
-20
-28.9
667
-13
-25
831
-10
-23.3
910
0
-17.8
1214
45
7.2
3580
-28.9
-20
178
-20
-28.9
228
-25
-13
222
-23.3
-10
243
-17.8
0
324
-12.2
10
42 4
-6.7
20
54 4
-1.1
30
68 9
4.4
40
859
-20
-28.9
3.59
-13
-25
253
-10
-23.3
26 4
0
-17.8
30 1
10
-12.2
338
20
-6.7
37 9
30
-1.1
42 2
40
4.4
470
45
7.2
496
-13
-25
3.70
-10
-23.3
3.76
0
-17.8
3.95
10
-12.2
4.16
20
-6.7
4.40
30
-1.1
4.67
40
4.4
4.96
45
7.2
5.11
-20
-28.9
3.28
-20
-28.9
2.92
-13
-25
3.69
-13
-25
3.28
-28.9
-20
0.78
-25
-13
0.88
10
12
11
13
Start winding
Thermostat
Main winding
14
Btu/Wh
-10
-23.3
3.88
0
-17.8
4.55
10
-12.2
5.28
20
-6.7
6.07
30
-1.1
6.89
40
4.4
7.73
-10
-23.3
3.45
0
-17.8
4.04
10
-12.2
4.69
20
-6.7
5.39
30
-1.1
6.11
40
4.4
6.85
-23.3
-10
0.92
-17.8
0
1.08
-12.2
10
1.25
-6.7
20
1.43
-1.1
30
1.63
4.4
40
1.82
45
7.2
8.15
Btu/Wh
a2
watt
8230
7.2
45
955
Current consumption
Comp.\F -30
Comp.\C -34.4
NF9.5FK 3.45
watt
Power consumption
Comp.\F -30
Comp.\C -34.4
NF9.5FK
192
a2
Btu/h
Motor protector
(pos.1)
45
7.2
7.22
W/W
7.2
45
1.92
c
a2
Accessories
Devices
Star ting relay (protector incl.)
Protector 3/4" Texas Instruments
Star ting relay (protector incl.)
Star ting capacitor 410 F
Protector 3/4" Texas Instruments
NF9.5FK
a2
(pos.1)
MRT26AFZ-6
a2
c
(pos.2)
117U4141
117U4142*
117U5028*
MRT26AFZ-6
Cover
117U1021
Cord relief
117U0317
dc
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
8226
Fig.
Test conditions
1. Condensing temperature
2. Ambient & suction gas temp.
3. Liquid temperature
Fan cooling F2, 115V 60Hz
dc
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. MBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
1.
55C (131F)
2.
32C (90F)
3.
55C (131F)
b
a2
c
10
12
Main winding
11
13
Start winding
Thermostat
14
(pos.2)
Motor protector
CG.43.W3.22
CK.40.A5.22
July 2003
41
NF5.5FX
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.43.Q6.22)
General
NF5.5FX
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Application
R134a
SUCTION
CONNECTOR
Blue stripe
Copper-plated steel
105G5623
Rubber plugs
Copper
105G
NF5.5FX
Code number
105G5633*)
Rubber plugs
5623
Barcode on
white background
105G5627
DANFOSS COMPRESSORS
8309-10
Compressor
Green background
Application
LBP/MBP
F (C)
V/Hz
95 - 135 /60
Motor type
THERMALLY
PROTECTED
CSIR
F (C)
110 (43)
Comp. cooling at
110F (43C)
O/F1
S
O
F1
F2
Design
3
10.8 (320)
oz. (g)
17.5 (500)
0.37 (6.13)
79.7 (2360)
22.0 (10.0)
lbs. (kg)
4.45"(113)
Motor
22.2
in. (mm) A
7.76 (197)
7.52 (191)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
25
3.68"(93.5)
Dimensions
A B
15
UL984/CSA-C22.2
E
C
2.0/3.1
Approvals
8.10"(205)
1.57"
(40)
22.2
4.69"(119)
5.00"(127)
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
265
47
35
watt
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor size
Height
27
51
(54)
fl.oz. (cm3)
3.01"(78)
cu.in. (cm )
Oil quantity
6.54"(166)
2.83"(72)
2.34" (59.5)
Displacement
2.97"(75.5)
Approval mark
1.57"
(40)
2.13"
Voltage range
NF5.5FX
115V-60Hz
1PH
4.04"(102.5)
8309-11
Application
F
8336
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
42
CD.43.Q7.22
CK.40.A5.22
July 2003
-20
-28.9
481
-13
-25
627
-10
-23.3
695
0
-17.8
950
Btu/h
10
-12.2
1257
20
-6.7
1625
30
-1.1
2065
40
4.4
2588
45
7.2
2884
0
-17.8
84 5
10
-12.2
1116
20
-6.7
1442
30
-1.1
1831
40
4.4
229 3
45
7.2
2555
-17.8
0
225
-12.2
10
297
-6.7
20
384
-1.1
30
48 8
4.4
40
611
7.2
45
680
-20
-28.9
428
-13
-25
558
-10
-23.3
618
Btu/h
-28.9
-20
114
-25
-13
148
-23.3
-10
165
c
a2
8226
watt
dc
b
a2
Power consumption
Comp.\F -30
Comp.\C -34.4
NF5.5FX 97.4
-20
-28.9
135
watt
-13
-25
159
-10
-23.3
169
0
-17.8
200
10
-12.2
228
20
-6.7
25 5
30
-1.1
280
40
4.4
30 5
45
7.2
317
10
12
Main winding
Current consumption
Comp.\F -30
Comp.\C -34.4
NF5.5FX 2.18
-20
-28.9
2.34
-20
-28.9
3.57
-10
-23.3
2.50
0
-17.8
2.67
10
-12.2
2.85
20
-6.7
3.04
30
-1.1
3.24
40
4.4
3.44
-13
-25
3.95
0
-17.8
4.76
10
-12.2
5.51
20
-6.7
6.38
30
-1.1
7.37
40
4.4
8.49
-10
-23.3
3.66
0
-17.8
4.23
10
-12.2
4.90
20
-6.7
5.66
30
-1.1
6.54
40
4.4
7.52
-23.3
-10
0.98
-17.8
0
1.13
-12.2
10
1.30
-6.7
20
1.50
-1.1
30
1.74
4.4
40
2.00
-10
-23.3
4.12
-20
-28.9
3.17
-13
-25
3.51
45
7.2
3.54
45
7.2
9.09
Btu/Wh
-28.9
-20
0.85
-25
-13
0.93
Motor protector
Btu/Wh
Thermostat
14
A
-13
-25
2.45
45
7.2
8.05
W/W Accessories
7.2
45
2.13
Devices
Starting relay (protector incl.)
Protector 3/4" Texas Instr.
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
July 2003
Start winding
11
13
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CD.43.Q7.22
CK.40.A5.22
Fig.
a2
NF5.5FX
117U4127
MRP36AEN-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
117U5025
July 2003
43
NF7FX
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.43.X3.22)
General
NF7FX
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Application
R134a
SUCTION
CONNECTOR
Blue stripe
Copper-plated steel
105G5723
Rubber plugs
Copper
105G
NF7FX
Code number
105G5733*)
Rubber plugs
5723
Barcode on
white background
105G5727
DANFOSS COMPRESSORS
8309
Compressor
Green background
Application
LBP/MBP
F (C)
V/Hz
95 - 135 /60
Motor type
THERMALLY
PROTECTED
CSIR
F (C)
110 (43)
Comp. cooling at
110F (43C)
O/F1
S
O
F1
F2
Design
3
10.8 (320)
oz. (g)
17.5 (500)
0.44 (7.27)
79.7 (2360)
22.0 (10.0)
lbs. (kg)
4.45"(113)
Motor
28.0
in. (mm) A
7.76 (197)
7.52 (191)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
25
3.68"(93.5)
Dimensions
A B
15
UL984/CSA-C22.2
E
C
1.9/6.6
Approvals
8.10"(205)
1.57"
(40)
28.0
4.69"(119)
5.00"(127)
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
310
47
35
watt
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor size
Height
27
51
(54)
fl.oz. (cm3)
3.01"(78)
cu.in. (cm )
Oil quantity
6.54"(166)
2.83"(72)
2.34" (59.5)
Displacement
2.97"(75.5)
Approval mark
1.57"
(40)
2.13"
Voltage range
NF7FX
115V-60Hz
1PH
4.04"(102.5)
8309-3
Application
F
8336
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
44
CG.43.X4.22
CK.40.A5.22
July 2003
-20
-28.9
618
-13
-25
782
-10
-23.3
858
0
-17.8
1147
Btu/h
10
-12.2
1495
20
-6.7
1918
30
-1.1
2428
40
4.4
3037
45
7.2
3383
0
-17.8
1019
10
-12.2
1328
20
-6.7
1703
30
-1.1
2153
40
4.4
2692
45
7.2
2997
-17.8
0
272
-12.2
10
355
-6.7
20
454
-1.1
30
57 4
4.4
40
71 7
7.2
45
799
-20
-28.9
550
-13
-25
695
-10
-23.3
763
Btu/h
-28.9
-20
147
-25
-13
186
-23.3
-10
204
c
a2
8226
watt
dc
b
a2
Power consumption
Comp.\F -30
Comp.\C -34.4
NF7FX
145
-20
-28.9
181
watt
-13
-25
20 5
-10
-23.3
215
0
-17.8
247
10
-12.2
279
20
-6.7
310
30
-1.1
341
40
4.4
372
45
7.2
388
10
12
Thermostat
Main winding
Current consumption
Comp.\F -30
Comp.\C -34.4
NF7FX
2.97
-20
-28.9
3.14
-20
-28.9
3.42
-10
-23.3
3.32
0
-17.8
3.50
10
-12.2
3.70
20
-6.7
3.90
30
-1.1
4.11
40
4.4
4.33
-13
-25
3.82
0
-17.8
4.63
10
-12.2
5.36
20
-6.7
6.19
30
-1.1
7.12
40
4.4
8.16
-10
-23.3
3.55
0
-17.8
4.12
10
-12.2
4.76
20
-6.7
5.49
30
-1.1
6.32
40
4.4
7.24
-23.3
-10
0.94
-17.8
0
1.10
-12.2
10
1.27
-6.7
20
1.46
-1.1
30
1.68
4.4
40
1.92
-10
-23.3
4.00
-20
-28.9
3.04
-13
-25
3.39
45
7.2
4.45
45
7.2
8.72
Btu/Wh
-28.9
-20
0.81
-25
-13
0.90
Motor protector
Btu/Wh
14
A
-13
-25
3.26
45
7.2
7.73
W/W Accessories
7.2
45
2.05
Devices
Fig.
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
July 2003
Start winding
11
13
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CG.43.X4.22
CK.40.A5.22
Protector 3/4"
a2
MRP30AEN-6
117U5025
Electrica
NF7FX
117U4061
T 0772/06
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
July 2003
45
NF9FX
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.43.R7.22)
General
NF9FX
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Application
R134a
SUCTION
CONNECTOR
Blue stripe
Copper-plated steel
105G5920
Rubber plugs
Copper
105G
NF9FX
Code number
105G5930*)
Rubber plugs
5920
Barcode on
white background
105G5927
DANFOSS COMPRESSORS
8309-2
Compressor
Green background
Application
LBP/MBP
F (C)
NF9FX
115V-60Hz
1PH
Voltage range
V/Hz
THERMALLY
PROTECTED
95 - 135 /60
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
LBP: F2
110F (43C)
MBP: O/F1
8309-4
Application
Approval mark
S
O
F1
F2
fl.oz. (cm3)
79.7 (2360)
lbs. (kg)
22.0 (10.0)
Motor
4.45"(113)
28.0
1.9/6.6
Approvals
UL984/CSA-C22.2
A B
1.57"
(40)
28.0
25
3.68"(93.5)
Dimensions
7.76 (197)
7.52 (191)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
in. (mm) A
5.20"(132)
4.00"(101.6)
2.76"(70)
Height
E
C
15
310
4.69"(119)
5.00"(127)
35
watt
47
8.10"(205)
Motor size
27
51
(54)
17.5 (500)
3.01"(78)
10.8 (320)
oz. (g)
0.51 (8.35)
2.97"(75.5)
fl.oz. (cm3)
1.57"
(40)
Oil quantity
2.13"
cu.in. (cm3)
4.04"(102.5)
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
F
8336
0.75"(19)
0.63"(16)
0.38"(9.7)
80
6.50"(165)
7.32"(186)
July 2003
46
CD.43.R8.22
CK.40.A5.22
July 2003
-13
-25
851
-10
-23.3
935
0
-17.8
1261
10
-12.2
1662
Btu/h
20
-6.7
2148
30
-1.1
2731
40
4.4
3420
20
-6.7
1907
30
-1.1
2422
40
4.4
3031
-13
-25
756
-10
-23.3
831
0
-17.8
1121
10
-12.2
1476
45
7.2
3808
Btu/h
c
45
7.2
3374
a2
8226
-25
-13
202
-23.3
-10
222
-17.8
0
299
watt
-12.2
10
394
-6.7
20
509
-1.1
30
646
4.4
40
809
7.2
45
900
dc
b
a2
Power consumption
Comp.\F -20
Comp.\C -28.9
NF9FX
213
-13
-25
235
watt
-10
-23.3
245
0
-17.8
277
10
-12.2
311
20
-6.7
347
30
-1.1
386
40
4.4
429
Current consumption
Comp.\F -20
Comp.\C -28.9
NF9FX
3.32
-13
-25
3.44
45
7.2
452
10
12
Main winding
A
-10
-23.3
3.50
0
-17.8
3.69
10
-12.2
3.92
20
-6.7
4.17
30
-1.1
4.45
40
4.4
4.75
Start winding
11
13
Thermostat
14
45
7.2
4.91
Motor protector
-13
-25
3.62
-10
-23.3
3.82
0
-17.8
4.55
Btu/Wh
10
-12.2
5.34
20
-6.7
6.19
30
-1.1
7.07
40
4.4
7.98
0
-17.8
4.04
10
-12.2
4.75
20
-6.7
5.49
30
-1.1
6.28
40
4.4
7.07
-17.8
0
1.08
-12.2
10
1.26
-6.7
20
1.46
-1.1
30
1.67
4.4
40
1.88
-13
-25
3.22
-10
-23.3
3.40
45
7.2
8.43
Btu/Wh
-25
-13
0.86
-23.3
-10
0.91
45
7.2
7.47
W/W
Accessories
7.2
45
1.99
Devices
Protector 3/4"
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
July 2003
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CD.43.R8.22
CK.40.A5.22
Fig.
a2
NF9FX
117U4129
MRT22AFZ-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
117U5025
July 2003
47
NF10FX
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.43.X4.22)
General
NF10FX
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
105G5941
Copper
Rubber plugs
105G5946
Application
105G
NF10FX
Code number
R134a
SUCTION
CONNECTOR
Blue stripe
5941
Barcode on
white background
DANFOSS COMPRESSORS
8309-7
Compressor
Green background
Application
LBP/MBP
NF10FX
115V-60Hz
1PH
V/Hz
95 - 135 /60
Motor type
THERMALLY
PROTECTED
CSIR
F (C)
110 (43)
110F (43C)
MBP: F1
Comp. cooling at
LBP: F2
8309-8
Application
S
O
F1
F2
Approval mark
oz. (g)
16.1 (460)
fl.oz. (cm3)
79.7 (2360)
lbs. (kg)
22.0 (10.0)
4.45"(113)
30.0
30.0
1.7/5.4
Approvals
UL984/CSA-C22.2
A B
15
4.04"(102.5)
9.92"(252)
8.03"(204)
6.70"(170)
Dimensions
B
7.76 (197)
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
8367
7.52 (191)
Suction connector
1.38"(35)
in. (mm) A
5.20"(132)
4.00"(101.6)
2.76"(70)
Height
E
C
25
330
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
47
8.10"(205)
Motor
27
51
(54)
10.8 (320)
3.01"(78)
0.62 (10.09)
fl.oz. (cm3)
2.13"
cu.in. (cm3)
Oil quantity
2.97"(75.5)
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
0.75"(19)
0.63"(16)
0.38"(9.7)
80
6.50"(165)
7.32"(186)
July 2003
48
CD.43.X5.22
CK.40.A5.22
July 2003
-13
-25
950
-10
-23.3
1046
0
-17.8
1411
10
-12.2
1854
Btu/h
20
-6.7
2391
30
-1.1
3036
40
4.4
3805
20
-6.7
2123
30
-1.1
2693
40
4.4
3372
45
7.2
4240
-13
-25
845
-10
-23.3
930
0
-17.8
1254
10
-12.2
1647
Btu/h
c
45
7.2
3756
a2
8226
-25
-13
227
-23.3
-10
249
-17.8
0
336
watt
-12.2
10
440
-6.7
20
567
-1.1
30
719
4.4
40
899
7.2
45
1001
dc
b
a2
Power consumption
Comp.\F -20
Comp.\C -28.9
NF10FX
225
-13
-25
250
watt
-10
-23.3
261
0
-17.8
302
10
-12.2
345
20
-6.7
391
30
-1.1
438
40
4.4
487
Current consumption
Comp.\F -20
Comp.\C -28.9
NF10FX
3.48
-13
-25
3.64
45
7.2
512
10
12
Main winding
A
-10
-23.3
3.71
0
-17.8
3.97
10
-12.2
4.25
20
-6.7
4.55
30
-1.1
4.87
40
4.4
5.21
Start winding
11
13
Thermostat
14
45
7.2
5.39
Motor protector
-13
-25
3.80
-10
-23.3
4.00
0
-17.8
4.68
Btu/Wh
10
-12.2
5.38
20
-6.7
6.12
30
-1.1
6.93
40
4.4
7.81
0
-17.8
4.16
10
-12.2
4.78
20
-6.7
5.43
30
-1.1
6.15
40
4.4
6.93
-17.8
0
1.11
-12.2
10
1.27
-6.7
20
1.45
-1.1
30
1.63
4.4
40
1.84
-13
-25
3.38
-10
-23.3
3.56
45
7.2
8.29
Btu/Wh
-25
-13
0.91
-23.3
-10
0.95
45
7.2
7.34
W/W
Accessories
7.2
45
1.95
Devices
Protector 3/4"
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
July 2003
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CD.43.X5.22
CK.40.A5.22
Fig.
a2
NF10FX
117U4129
MRT22AFZ-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
117U5022
July 2003
49
NF11FX
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.Y4.22)
General
NF11FX
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
105G5945
Copper
Rubber plugs
105G5947
Application
105G
NF11FX
Code number
R134a
SUCTION
CONNECTOR
Blue stripe
5945
Barcode on
white background
DANFOSS COMPRESSORS
8309-5
Compressor
Green background
Application
MBP
NF11FX
115V-60Hz
1PH
10 to 45 (-12.2 to 7.2)
F (C)
Voltage range
V/Hz
95 - 127 /60
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
S
O
F1
F2
8309-9
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
10.8 (320)
oz. (g)
14.0 (400)
22.0 (10.0)
4.45"(113)
43.1
43.1
1.0/3.6
UL984/CSA-C22.2
A B
Dimensions
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
in. (mm) A
5.20"(132)
4.00"(101.6)
2.76"(70)
Height
15
Approvals
8.10"(205)
4.04"(102.5)
530
35
watt
25
Motor size
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor
47
(54)
lbs. (kg)
27
51
2.13"
79.7 (2360)
3.01"(78)
fl.oz. (cm3)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.68 (11.15)
8367
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
50
CD.43.Y5.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
10
Comp.\C -12.2
NF11FX
1755
20
-6.7
2271
Btu/h
30
-1.1
2890
40
4.4
3627
41
5
3708
-6.7
20
606
-1.1
30
771
4.4
40
967
45
7.2
4044
watt
5
41
988
7.2
45
1078
a2
8226
Power consumption
Comp.\F
10
Comp.\C -12.2
NF11FX
390
20
-6.7
441
watt
30
-1.1
495
40
4.4
550
41
5
556
45
7.2
578
dc
b
a2
Current consumption
Comp.\F
10
Comp.\C -12.2
NF11FX
5.45
20
-6.7
5.81
A
30
-1.1
6.19
40
4.4
6.60
41
5
6.64
45
7.2
6.81
10
12
Main winding
EER (ASHRAE)
Comp.\F
10
Comp.\C -12.2
NF11FX
4.50
Btu/Wh
20
-6.7
5.14
30
-1.1
5.84
40
4.4
6.59
41
5
6.67
45
7.2
7.00
11
13
Start winding
Thermostat
14
Motor protector
-6.7
20
1.37
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
-1.1
30
1.55
W/W
4.4
40
1.75
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
5
41
1.77
7.2
45
1.85
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
a2
MRT16AFZ-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
July 2003
Texas Instr.
NF11FX
117U4123
117U5028
CD.43.Y5.22
CK.40.A5.22
July 2003
51
NF6.1FX.2
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CH.43.W2.22)
General
NF6.1FX.2
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NF6.1FX.2
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5631
5631
Barcode on
white background
8516
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP/MBP
NF6.1FX.2
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
95 - 135 /60
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
O/F1
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8516-5
Application
14.0 (400)
79.7 (2360)
22.0 (10.0)
lbs. (kg)
27
51
4.45"(113)
22.2
22.2
2.0/3.1
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
7.76 (197)
7.52 (191)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
0.252-0.259 (6.50.09)
80
A B
15
Approvals
C
35
4.04"(102.5)
8.10"(205)
25
265
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
10.8 (320)
oz. (g)
2.13"
0.37 (6.13)
fl.oz. (cm3)
3.01"(78)
cu.in. (cm3)
Oil quantity
2.97"(75.5)
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
8367
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
52
CH.43.W3.22
CK.40.A5.22
July 2003
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
709
0
-17.8
Btu/h
10
-12.2
20
-6.7
1686
30
-1.1
40
4.4
10
-12.2
20
-6.7
1496
30
-1.1
40
4.4
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
630
0
-17.8
45
7.2
Btu/h
c
45
7.2
a2
8226
-28.9
-20
-25
-13
-23.3
-10
168
watt
-17.8
0
-12.2
10
-6.7
20
398
-1.1
30
4.4
40
-30
-34.4
-20
-28.9
-30
-34.4
-20
-28.9
a2
watt
-13
-25
-10
-23.3
163
0
-17.8
10
-12.2
20
-6.7
240
30
-1.1
40
4.4
45
7.2
Current consumption
Comp.\F
Comp.\C
NF6.1FX.2
dc
b
Power consumption
Comp.\F
Comp.\C
NF6.1FX.2
7.2
45
10
12
A
-13
-25
-10
-23.3
2.50
0
-17.8
10
-12.2
20
-6.7
2.90
30
-1.1
40
4.4
Main winding
Start winding
11
13
Thermostat
14
45
7.2
M
Motor protector
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
4.35
Btu/Wh
0
-17.8
10
-12.2
20
-6.7
7.03
30
-1.1
40
4.4
-10
-23.3
3.87
0
-17.8
10
-12.2
20
-6.7
6.23
30
-1.1
40
4.4
-23.3
-10
1.03
-17.8
0
-12.2
10
-6.7
20
1.66
-1.1
30
4.4
40
-30
-34.4
-20
-28.9
-13
-25
Btu/Wh
-34.4
-30
-28.9
-20
-25
-13
45
7.2
45
7.2
W/W Accessories
7.2
45
Devices
Protector 3/4"
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
preliminary data
July 2003
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CH.43.W3.22
CK.40.A5.22
Fig.
a2
NF6.1FX.2
117U4127
MRP36AEN-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
117U5025
July 2003
53
NF7.3FX.2
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CH.43.X2.22)
General
NF7.3FX.2
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NF7.3FX.2
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5722
5722
Barcode on
white background
8516-2
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP/MBP
NF7.3FX.2
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
95 - 135 /60
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
O/F1
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8516-6
Application
14.0 (400)
79.7 (2360)
22.0 (10.0)
lbs. (kg)
27
51
4.45"(113)
28.0
28.0
1.9/6.6
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
7.76 (197)
7.52 (191)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
0.252-0.259 (6.50.09)
80
A B
15
Approvals
C
35
4.04"(102.5)
8.10"(205)
25
310
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
10.8 (320)
oz. (g)
2.13"
0.44 (7.27)
fl.oz. (cm3)
3.01"(78)
cu.in. (cm3)
Oil quantity
2.97"(75.5)
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
8367
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
54
CH.43.X3.22
CK.40.A5.22
July 2003
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
834
0
-17.8
Btu/h
10
-12.2
20
-6.7
1994
30
-1.1
40
4.4
10
-12.2
20
-6.7
1771
30
-1.1
40
4.4
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
742
0
-17.8
45
7.2
Btu/h
c
45
7.2
a2
8226
-34.4
-30
-28.9
-20
-25
-13
-23.3
-10
198
watt
-17.8
0
-12.2
10
-6.7
20
472
-1.1
30
4.4
40
-30
-34.4
-20
-28.9
-30
-34.4
-20
-28.9
a2
watt
-13
-25
-10
-23.3
197
0
-17.8
10
-12.2
20
-6.7
293
30
-1.1
40
4.4
45
7.2
Current consumption
Comp.\F
Comp.\C
NF7.3FX.2
dc
b
Power consumption
Comp.\F
Comp.\C
NF7.3FX.2
7.2
45
10
12
A
-13
-25
-10
-23.3
3.20
0
-17.8
10
-12.2
20
-6.7
3.70
30
-1.1
40
4.4
Start winding
11
13
Thermostat
Main winding
14
45
7.2
M
Motor protector
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
4.29
Btu/Wh
0
-17.8
10
-12.2
20
-6.7
6.81
30
-1.1
40
4.4
-10
-23.3
3.78
0
-17.8
10
-12.2
20
-6.7
6.04
30
-1.1
40
4.4
-23.3
-10
1.01
-17.8
0
-12.2
10
-6.7
20
1.61
-1.1
30
4.4
40
-30
-34.4
-20
-28.9
-13
-25
Btu/Wh
-34.4
-30
-28.9
-20
-25
-13
45
7.2
45
7.2
W/W
Accessories
7.2
45
Devices
Protector 3/4" Texas Instr.
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
preliminary data
July 2003
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CH.43.X3.22
CK.40.A5.22
Fig.
NF7.3FX.2
a2
MRP30AEN-6
117U5025
117U4061
Electrica
T 0772/06
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
July 2003
55
NF8.4FX.2
Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CH.43.Y2.22)
General
NF8.4FX.2
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NF8.4FX.2
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5918
5918
Barcode on
white background
8516-3
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP/MBP
NF8.4FX.2
115V-60Hz
1PH
V/Hz
95 - 135 /60
Motor type
CSIR
F (C)
110 (43)
Comp. cooling at
LBP: F2
110F (43C)
MBP: O/F1
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8516-7
Application
oz. (g)
14.0 (400)
79.7 (2360)
22.0 (10.0)
lbs. (kg)
4.45"(113)
28.0
1.9/6.6
Approvals
UL984/CSA-C22.2
A B
15
4.04"(102.5)
28.0
25
310
9.92"(252)
8.03"(204)
6.70"(170)
7.76 (197)
7.52 (191)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
0.252-0.259 (6.50.09)
1.38"(35)
in. (mm) A
5.20"(132)
4.00"(101.6)
2.76"(70)
Dimensions
Height
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
47
8.10"(205)
Motor
27
51
(54)
10.8 (320)
2.13"
0.51 (8.35)
fl.oz. (cm3)
3.01"(78)
cu.in. (cm3)
Oil quantity
2.97"(75.5)
Displacement
6.54"(166)
2.83"(72)
2.34" (59.5)
Design
8367
0.75"(19)
0.63"(16)
0.38"(9.7)
80
6.50"(165)
7.32"(186)
July 2003
56
CH.43.Y3.22
CK.40.A5.22
July 2003
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
954
0
-17.8
Btu/h
10
-12.2
20
-6.7
2264
30
-1.1
40
4.4
10
-12.2
20
-6.7
2010
30
-1.1
40
4.4
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
848
0
-17.8
45
7.2
Btu/h
c
45
7.2
a2
8226
-34.4
-30
-28.9
-20
-25
-13
-23.3
-10
227
watt
-17.8
0
-12.2
10
-6.7
20
536
-1.1
30
4.4
40
-30
-34.4
-20
-28.9
-30
-34.4
-20
-28.9
a2
watt
-13
-25
-10
-23.3
223
0
-17.8
10
-12.2
20
-6.7
336
30
-1.1
40
4.4
45
7.2
Current consumption
Comp.\F
Comp.\C
NF8.4FX.2
dc
b
Power consumption
Comp.\F
Comp.\C
NF8.4FX.2
7.2
45
10
12
A
-13
-25
-10
-23.3
3.40
0
-17.8
10
-12.2
20
-6.7
4.00
30
-1.1
40
4.4
Main winding
Start winding
11
13
Thermostat
14
45
7.2
M
Motor protector
-30
-34.4
-20
-28.9
-13
-25
-10
-23.3
4.28
Btu/Wh
0
-17.8
10
-12.2
20
-6.7
6.73
30
-1.1
40
4.4
-10
-23.3
3.80
0
-17.8
10
-12.2
20
-6.7
5.98
30
-1.1
40
4.4
-23.3
-10
1.02
-17.8
0
-12.2
10
-6.7
20
1.60
-1.1
30
4.4
40
-30
-34.4
-20
-28.9
-13
-25
Btu/Wh
-34.4
-30
-28.9
-20
-25
-13
45
7.2
45
7.2
W/W
Accessories
7.2
45
Devices
Starting relay (protector incl.)
Protector 3/4" Texas Instr.
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
preliminary data
July 2003
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CH.43.Y3.22
CK.40.A5.22
Fig.
a2
NF8.4FX.2
117U4129
MRT22AFZ-6
Cover
117U1021
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one comp.
Bolt joint for one comp.
Snap-on for one comp.
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
117U5025
July 2003
57
FF8.5FK
Standard Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.U3.22)
General
Compressor (CU-plated steel connectors)
103G
FF8.5FK
FF8.5FK
Codenumber
Application
103G5810
R134a
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/MBP
Barcode on
white background
Green background
5810
DANFOSS COMPRESSORS
F (C)
FF8.5FK
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F2
S
O
F1
F2
THERMALLY
PROTECTED
8332-2
Motor type
8332
Blue stripe
Application
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
13.5 (400)
oz. (g)
32.0 (900)
Motor size
LRA (rated after 4 sec.UL984) LST
watt
255
29.4
29.4
3.98"(101)
4.33"(110)
7.87"(200)
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
8.03"(204)
6.50"(165)
6.69"(170)
7.32"(186)
CD.43.U4.22
CK.40.A5.22
0.75"(19)
0.63"(16)
0.38"(9.7)
58
(55)
4.80"(122)
5.87"(149)
9.84"(250)
5.31"(135)
Suction connector
(35)
7.52 (191)
1.38"
7.72 (196)
4.00"(101.6)
2.76"(70)
in. (mm) A
5.75"(146)
A B
July 2003
C
E
UL984/CSA-C22.2
Dimensions
Compressors on a pallet
(32)
4.10"(103)
2.0/9.1
Approvals
Height
24
1.26"
Motor
2.17"
23.3 (10.6)
40
47.3 (1400)
lbs. (kg)
40
fl.oz. (cm3)
2.34" (59.5)
6.14"(156)
2.17"(55)
0.48 (7.95)
8337
July 2003
-20
-28.9
413
-13
-25
563
-10
-23.3
635
0
-17.8
91 1
Btu/h
10
-12.2
1250
20
-6.7
1662
30
-1.1
2157
40
4.4
2745
45
7.2
3078
a2
-20
-28.9
367
-13
-25
500
-10
-23.3
564
Btu/h
0
-17.8
809
10
-12.2
1110
20
-6.7
1475
30
-1.1
1914
40
4.4
2433
-17.8
0
215
-12.2
10
295
-6.7
20
392
-1.1
30
509
4.4
40
647
-28.9
-20
97
-25
-13
132
-23.3
-10
149
-20
-28.9
159
b
8230
watt
Power consumption
Comp.\F -30
Comp.\C -34.4
FF8.5FK
13 1
45
7.2
2726
7.2
45
725
a2
watt
-13
-25
181
-10
-23.3
191
0
-17.8
226
10
-12.2
264
20
-6.7
306
30
-1.1
350
40
4.4
396
45
7.2
420
10
12
Main winding
Current consumption
Comp.\F -30
Comp.\C -34.4
FF8.5FK
2.61
-20
-28.9
2.77
-20
-28.9
2.59
-13
-25
2.90
-10
-23.3
2.96
0
-17.8
3.18
10
-12.2
3.43
20
-6.7
3.72
30
-1.1
4.04
40
4.4
4.40
-13
-25
3.11
0
-17.8
4.03
10
-12.2
4.73
20
-6.7
5.44
30
-1.1
6.17
40
4.4
6.93
-10
-23.3
2.95
0
-17.8
3.58
10
-12.2
4.20
20
-6.7
4.83
30
-1.1
5.47
40
4.4
6.14
-23.3
-10
0.78
-17.8
0
0.95
-12.2
10
1.11
-6.7
20
1.28
-1.1
30
1.45
4.4
40
1.63
-10
-23.3
3.32
-20
-28.9
2.30
-13
-25
2.76
-28.9
-20
0.61
-25
-13
0.73
45
7.2
4.59
Motor protector
45
7.2
7.32
Btu/Wh
Thermostat
14
Btu/Wh
45
7.2
6.49
W/W
7.2
45
1.72
Accessories
Devices
Starting relay (protector incl.)
Protector 3/4" Texas Instr.
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 115V 60Hz
July 2003
Start winding
11
13
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (MBP)
130F (54.4C)
95F (35C)
115F (46C)
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
CK.40.A5.22
a2
FF8.5FK
117U4062
MRP26EL-6
Cover
117U1021
Cord relief
117U0349
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
CD.43.U4.22
Fig.
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
59
TTE3FK
Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.42.V3.22)
General
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
102G3340
Copper
Rubber plugs
102G3341
102G
TTE3FK
TTE3FK
Connector-material
Application
Code number
R134a
Blue stripe
3340
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8424
Compressor
LBP
F (C)
Voltage range
Motor type
RSIR/RSCR
F (C)
110 (43)
S
O
F1
Comp. cooling at
max. ambient temperature
TTE3FK
115V-60Hz
1PH
V/Hz
110F (43C)
F2
THERMALLY
PROTECTED
8424-2
Application
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
fl.oz. (cm3)
54.2 (1600)
lbs. (kg)
4.02"(102)
98
6.0
16.0
UL984/CSA-C22.2
(29)
6.93"(176)
D
C
E
5.4/4.2
Approvals
or
8.90"(226)
31.5
28
C or
D
8370
A B
4.13"(105)
4.21"(107)
watt
4.13"(105)
Motor size
3.78"(96)
4.61"(117)
30
Motor
1.14"
51 20
6.18"(157)
16.5 (7.5)
2.80"(71)
45
2.34"(59.5)
2.60" (66)
0.19 (3.13)
Dimensions
6.26 (159)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
0.75"(19)
6.50"(165)
0.63"(16)
0.14"(3.6)
0.189-0.193 (4.9+0.10/-0)
5.35"(136)
6.42 (163)
2.76"(70)
in. (mm) A
4.00"(101.6)
Height
125
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
60
CG.42.V4.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TTE3FK
-30
-34.4
110
-20
-28.9
181
Btu/h
-13
-25
248
-10
-23.3
280
0
-17.8
400
10
-12.2
550
20
-6.7
650
-23.3
-10
66
-17.8
0
94
-12.2
10
130
-6.7
20
154
-34.4
-30
26
-28.9
-20
42
-25
-13
58
watt
Power consumption
Comp.\F
Comp.\C
TTE3FK
-30
-34.4
-20
-28.9
-30
-34.4
-20
-28.9
-13
-25
68
-10
-23.3
72
0
-17.8
10
-12.2
-30
-34.4
20
-6.7
-13
-25
1.13
-10
-23.3
1.15
0
-17.8
10
-12.2
-34.4
-30
1
2
4
3
20
-6.7
a1
Start winding
Btu/Wh
-20
-28.9
-13
-25
3.63
-10
-23.3
3.90
0
-17.8
10
-12.2
20
-6.7
-23.3
-10
0.92
-17.8
0
-12.2
10
-6.7
20
EER (ASHRAE)
Comp.\F
Comp.\C
TTE3FK
a1
watt
Current consumption
1Comp.\F
Comp.\C
TTE3FK
8234
-28.9
-20
Main winding
W/W
-25
-13
0.86
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54.4C)
55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.,
preliminary data
Motor protector
8233
Accessories
Devices
PTC starting device (Texas Instr.)
with reduced loss of energy
a1
TTE3FK
a1
117U6102
117U6106
a1 (w. RC)
(alternative)
a1 (w.o. RC)
(alternative)
J506-A120-A120
Cover
117U1026
117-7118
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
TI 8EA 4B3
July 2003
Fig.
1
2
4
3
J506-A120-A320
117U6105
e
a1
Start winding
Main winding
117U3313
TI-4TM265NFBYY-53
118-1946
118-1949
118-1947
Motor protector
CG.42.V4.22
CK.40.A5.22
July 2003
61
TTE4F
Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.42.W3.22)
General
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
102G3440
Copper
Rubber plugs
102G3441
102G
TTE4F
TTE4F
Connector-material
Application
Code number
R134a
Blue stripe
3440
Barcode on
white background
8331
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
F (C)
Voltage range
V/Hz
Motor type
S
O
F1
RSCR*
F (C)
110 (43)
Comp. cooling at
F2
110F (43C)
TTE4F
115V-60Hz
1PH
8331-2
Application
THERMALLY
PROTECTED
Approval mark
14.0 (400)
fl.oz. (cm3)
4.02"(102)
60.6 (1790)
lbs. (kg)
C or
D
16.5 (7.5)
3.78"(96)
4.61"(117)
(29)
6.1 (180)
oz. (g)
0.23 (3.86)
1.14"
fl.oz. (cm3)
2.80"(71)
Oil quantity
51 20
6.18"(157)
cu.in. (cm3)
45
Displacement
2.34"(59.5)
2.60" (66)
Design
8370
or
8.90"(226)
6.93"(176)
D
C
E
watt
125
8.3
A B
17.7
4.13"(105)
4.21"(107)
Motor size
4.13"(105)
30
31.5
28
Motor
4.2/4.0
Approvals
UL984/CSA-C22.2
0.75"(19)
6.50"(165)
0.63"(16)
in. (mm) A
B
6.65 (169)
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
July 2003
62
6.81 (173)
5.35"(136)
Height
102G3441
2.76"(70)
102G3440
4.00"(101.6)
0.14"(3.6)
Dimensions
pcs.
6.70"(170)
7.01"(178)
8.03"(204)
125
CD.42.W4.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TTE4F
-30
-34.4
164
-20
-28.9
269
Btu/h
-13
-25
356
-10
-23.3
397
0
-17.8
553
10
-12.2
740
14
-10
825
-34.4
-30
39
-28.9
-20
65
-25
-13
85
watt
-23.3
-10
95
-17.8
0
132
-12.2
10
177
8233
-10
14
197
a1
Power consumption
Comp.\F
Comp.\C
TTE4F
-30
-34.4
65
watt
-20
-28.9
79
-13
-25
89
-10
-23.3
94
0
-17.8
110
10
-12.2
126
14
-10
133
-13
-25
1.26
-10
-23.3
1.29
0
-17.8
1.39
10
-12.2
1.50
14
-10
1.55
Current consumption
Comp.\F
Comp.\C
TTE4F
-30
-34.4
1.13
-20
-28.9
1.21
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TTE4F
-30
-34.4
2.54
Btu/Wh
-20
-28.9
3.40
-13
-25
3.98
-10
-23.3
4.23
0
-17.8
5.04
10
-12.2
5.86
14
-10
6.19
-23.3
-10
1.01
-17.8
0
1.21
-12.2
10
1.40
-10
14
1.48
-34.4
-30
0.61
-28.9
-20
0.82
-25
-13
0.95
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
TTE4F
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3304
TI-4TM302NFBYY-53
118-1946
118-1949
118-1947
CD.42.W4.22
CK.40.A5.22
July 2003
63
NLE5.5F
Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.B4.22)
General
Compressor (CU-plated steel connectors)
105G
NLE5.5F
NLE5.5F
Codenumber
Application
105G5605
R134a
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP
Barcode on
white background
Green background
5605
DANFOSS COMPRESSORS
RSCR*
F (C)
NLE5.5F
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
S
O
F1
F2
8315-2
Motor type
8315
Blue stripe
Application
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
10.8 (320)
oz. (g)
14.0 (400)
79.7 (2360)
lbs. (kg)
25.0 (11.4)
Motor
Motor size
watt
150
11.3
21.8
3.0/3.7
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
3.68"(93.5)
0.75"(19)
0.63"(16)
CD.43.B5.22
CK.40.A5.22
2.76"(70)
1.38"
(35)
80
5.20"(132)
4.00"(101.6)
pcs.
10.00"(254)
8.03"(204)
6.70"(170)
2.97"(75.5)
4.04"(102.5)
Process connector
15
7.52 (191)
0.320-0.327 (8.20.09)
6.50"(165)
7.32"(186)
64
35
7.76 (198)
June 2003
8247
8.10"(205)
A B
in. (mm) A
Suction connector
Compressors on a pallet
4.69"(119)
5.00"(127)
UL984/CSA-C22.2
Dimensions
Height
4.45"(113)
47
25
Approvals
27
51
(54)
fl.oz. (cm3)
3.01"(78)
2.13"
6.54"(166)
2.83"(72)
2.38" (60.5)
0.37 (6.13)
0.38"(9.7)
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NLE5.5F
-30
-34.4
298
-20
-28.9
458
Btu/h
-13
-25
603
-10
-23.3
674
0
-17.8
936
10
-12.2
1251
14
-10
1388
-23.3
-10
160
-17.8
0
222
-12.2
10
297
-10
14
329
-34.4
-30
70
-28.9
-20
109
-25
-13
143
watt
Power consumption
Comp.\F
Comp.\C
NLE5.5F
-30
-34.4
86
-20
-28.9
109
b
8223-2
a1
watt
-13
-25
126
-10
-23.3
134
0
-17.8
160
10
-12.2
189
14
-10
200
d
e
Main winding
Current consumption
Comp.\F
Comp.\C
NLE5.5F
-30
-34.4
0.77
-20
-28.9
0.96
-13
-25
1.11
-10
-23.3
1.18
0
-17.8
1.41
10
-12.2
1.66
EER (ASHRAE)
Comp.\F
Comp.\C
NLE5.5F
-30
-34.4
3.46
-34.4
-30
0.82
a1
Start winding
14
-10
1.75
Btu/Wh
-20
-28.9
4.22
-13
-25
4.79
-10
-23.3
5.04
0
-17.8
5.84
10
-12.2
6.63
14
-10
6.93
-23.3
-10
1.20
-17.8
0
1.39
-12.2
10
1.57
-10
14
1.64
-28.9
-20
1.00
-25
-13
1.14
Winding protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades
NLE5.5F
a1
103N0017
103N0024
Cover
103N2011
Cord relief
103N1010
117-7118
117-7120
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Fig.
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CD.43.B5.22
CK.40.A5.22
June 2003
65
NLE6F
Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.43.Y1.22)
General
Compressor (CU-plated steel connectors)
NLE6F
Codenumber
105G5606
Codenumber
105G5609
105G
NLE6F
Application
R134a
Blue stripe
Application
LBP
-31 to 14 (-35 to -10)
110 (43)
F2
Design
Displacement
cu.in. (cm3)
0.40 (6.58)
Oil quantity
fl.oz. (cm3)
10.8 (320)
oz. (g)
14.0 (400)
fl.oz. (cm3)
79.7 (2360)
lbs. (kg)
25.0 (11.4)
4.45"(113)
3.68"(93.5)
11.3
21.8
5.20"(132)
4.00"(101.6)
UL984/CSA-C22.2
Dimensions
105G5606
in. (mm) A
B
0.75"(19)
0.63"(16)
105G5609
7.76 (198)
6.50"(165)
7.32"(186)
0.38"(9.7)
7.52 (191)
0.252-0.259 (6.50.09)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
Compressors on a pallet
66
10.00"(254)
8.03"(204)
6.70"(170)
3.0/3.7
Approvals
Height
15
150
8247
35
watt
4.69"(119)
5.00"(127)
Motor
LRA (rated after 4 sec.UL984) LST
47
8.10"(205)
A B
Motor size
27
51
(35)
Approval mark
THERMALLY
PROTECTED
4.04"(102.5)
110F (43C)
6.54"(166)
2.83"(72)
2.38" (60.5)
8315-5
F (C)
NLE6F
115V-60Hz
1PH
2.76"(70)
(54)
S
O
F1
RSCR*
2.13"
3.01"(78)
V/Hz
Motor type
1.38"
Voltage range
2.97"(75.5)
F (C)
25
June 2003
DANFOSS COMPRESSORS
Green background
Application
8315-4
5606
Barcode on
white background
pcs.
80
CG.43.Y2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NLE6F
-30
-34.4
375
-20
-28.9
514
Btu/h
-13
-25
654
-10
-23.3
726
0
-17.8
1005
10
-12.2
1360
14
-10
1519
-23.3
-10
172
-17.8
0
238
-12.2
10
322
-10
14
360
-34.4
-30
89
-28.9
-20
121
-25
-13
155
watt
Power consumption
Comp.\F
Comp.\C
NLE6F
-30
-34.4
99
-20
-28.9
120
b
8223-2
a1
watt
-13
-25
136
-10
-23.3
143
0
-17.8
168
10
-12.2
195
14
-10
207
d
e
Main winding
Current consumption
Comp.\F
Comp.\C
NLE6F
-30
-34.4
0.82
-20
-28.9
1.04
-13
-25
1.19
-10
-23.3
1.26
0
-17.8
1.48
10
-12.2
1.71
EER (ASHRAE)
Comp.\F
Comp.\C
NLE6F
-30
-34.4
3.80
14
-10
1.80
-34.4
-30
0.90
a1
Start winding
Btu/Wh
-20
-28.9
4.29
-13
-25
4.81
-10
-23.3
5.07
0
-17.8
5.98
10
-12.2
6.96
14
-10
7.35
-23.3
-10
1.20
-17.8
0
1.41
-12.2
10
1.65
-10
14
1.74
-28.9
-20
1.01
-25
-13
1.14
Winding protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades
NLE6F
a1
103N0017
103N0024
Cover
103N2011
Cord relief
103N1010
117-7118
117-7120
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Fig.
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.43.Y2.22
CK.40.A5.22
June 2003
67
NLE7F
Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.43.Z1.22)
General
Compressor (CU-plated steel connectors)
NLE7F
105G5702
105G5703
105G
NLE7F
Application
R134a
Blue stripe
Application
LBP
-31 to 14 (-35 to -10)
110 (43)
F2
110F (43C)
Design
Displacement
cu.in. (cm3)
0.44 (7.30)
Oil quantity
fl.oz. (cm3)
10.8 (320)
oz. (g)
79.7 (2360)
lbs. (kg)
25.0 (11.4)
4.69"(119)
5.00"(127)
13.2
22.5
10.00"(254)
8.03"(204)
6.70"(170)
Dimensions
105G5702
in. (mm) A
B
1.38"(35)
5.20"(132)
4.00"(101.6)
UL984/CSA-C22.2
105G5703
7.76 (198)
6.50"(165)
7.32"(186)
0.38"(9.7)
7.52 (191)
0.242-0.249 (6.20.09)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
0.242-0.249 (6.20.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
Compressors on a pallet
0.75"(19)
0.63"(16)
2.6/4.1
Approvals
Height
4.04"(102.5)
3.68"(93.5)
15
170
35
watt
8409
Motor
Motor size
47
8.10"(205)
14.0 (400)
fl.oz. (cm3)
27
51
4.45"(113)
A B
68
Approval mark
3.94"(100)
THERMALLY
PROTECTED
S
6.54"(166)
2.83"(72)
2.38" (60.5)
8315-7
F (C)
NLE7F
115V-60Hz
1PH
2.76"(70)
(54)
S
O
F1
RSCR*
2.13"
Motor type
3.01"(78)
V/Hz
2.97"(75.5)
F (C)
Voltage range
25
June 2003
DANFOSS COMPRESSORS
Green background
Application
8315-6
5702
Barcode on
white background
pcs.
80
CG.43.Z2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NLE7F
-30
-34.4
435
-20
-28.9
590
Btu/h
-13
-25
743
-10
-23.3
821
0
-17.8
1120
10
-12.2
1498
14
-10
1666
-23.3
-10
195
-17.8
0
266
-12.2
10
356
-10
14
396
-34.4
-30
104
-28.9
-20
141
-25
-13
177
watt
Power consumption
Comp.\F
Comp.\C
NLE7F
-30
-34.4
113
-20
-28.9
136
b
8223-2
a1
watt
-13
-25
154
-10
-23.3
162
0
-17.8
192
10
-12.2
224
14
-10
238
d
e
Main winding
Current consumption
Comp.\F
Comp.\C
NLE7F
-30
-34.4
1.05
-20
-28.9
1.23
-13
-25
1.39
-10
-23.3
1.46
0
-17.8
1.72
10
-12.2
2.00
EER (ASHRAE)
Comp.\F
Comp.\C
NLE7F
-30
-34.4
3.83
14
-10
2.12
-34.4
-30
0.92
a1
Start winding
Btu/Wh
-20
-28.9
4.35
-13
-25
4.83
-10
-23.3
5.06
0
-17.8
5.85
10
-12.2
6.68
14
-10
7.01
-23.3
-10
1.20
-17.8
0
1.39
-12.2
10
1.59
-10
14
1.66
-28.9
-20
1.04
-25
-13
1.15
Winding protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device
1
/4 in. (6.3 mm) spades
3
/16 in. (4.8 mm) spades
NLE7F
a1
103N0017
103N0024
Cover
103N2011
Cord relief
103N1010
117-7118
117-7120
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Fig.
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.43.Z2.22
CK.40.A5.22
June 2003
69
TTY5F
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.42.V3.22)
General
TTY5F
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
102G3547
Copper
Rubber plugs
102G3549
102G
TTY5F
Application
Code number
R134a
SUCTION
CONNECTOR
Blue stripe
3547
Barcode on
white background
8322
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
F (C)
Voltage range
V/Hz
Motor type
S
O
F1
RSCR*
F (C)
110 (43)
Comp. cooling at
F2
110F (43C)
TTY5F
115V-60Hz
1PH
8322-2
Application
THERMALLY
PROTECTED
Approval mark
14.0 (400)
fl.oz. (cm3)
4.02"(102)
60.6 (1790)
lbs. (kg)
17.6 (8.0)
3.78"(96)
4.61"(117)
(29)
6.1 (180)
oz. (g)
0.34 (5.54)
1.14"
fl.oz. (cm3)
2.80"(71)
Oil quantity
51 20
cu.in. (cm3)
45
6.18"(157)
Design
Displacement
2.34"(59.5)
2.60" (66)
8368
8.90"(226)
6.93"(176)
E
watt
180
11.3
A B
21.5
4.13"(105)
4.21"(107)
Motor size
4.13"(105)
30
31.5
28
Motor
3.2/3.7
Approvals
UL984/CSA-C22.2
0.75"(19)
6.50"(165)
0.63"(16)
in. (mm) A
B
6.65 (169)
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
July 2003
70
6.81 (173)
5.35"(136)
Height
102G3549
2.76"(70)
102G3547
4.00"(101.6)
0.14"(3.6)
Dimensions
pcs.
0.252-0.259 (6.50.09)
6.70"(170)
7.01"(178)
8.03"(204)
125
CD.42.V4.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TTY5F
-30
-34.4
275
-20
-28.9
412
Btu/h
-13
-25
532
-10
-23.3
590
0
-17.8
814
10
-12.2
1091
14
-10
1218
-34.4
-30
66
-28.9
-20
99
-25
-13
128
watt
-23.3
-10
141
-17.8
0
195
-12.2
10
261
8233
-10
14
291
a1
Power consumption
Comp.\F
Comp.\C
TTY5F
-30
-34.4
86
watt
-20
-28.9
105
-13
-25
119
-10
-23.3
126
0
-17.8
147
10
-12.2
171
14
-10
182
-13
-25
1.18
-10
-23.3
1.23
0
-17.8
1.42
10
-12.2
1.62
14
-10
1.71
Current consumption
Comp.\F
Comp.\C
TTY5F
-30
-34.4
0.92
-20
-28.9
1.07
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TTY5F
-30
-34.4
3.21
Btu/Wh
-20
-28.9
3.91
-13
-25
4.46
-10
-23.3
4.70
0
-17.8
5.54
10
-12.2
6.38
14
-10
6.71
-23.3
-10
1.13
-17.8
0
1.33
-12.2
10
1.53
-10
14
1.60
-34.4
-30
0.77
-28.9
-20
0.94
-25
-13
1.07
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
TTY5F
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3302
TI-4TM314NFBYY-53
118-1946
118-1949
118-1947
CD.42.V4.22
CK.40.A5.22
July 2003
71
TTY6F
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.42.R1.22)
General
TTY6F
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
102G
TTY6F
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
102G3647
3647
Barcode on
white background
DANFOSS COMPRESSORS
8322-3
Compressor
Green background
Application
LBP
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
S
O
F1
F2
110F (43C)
TTY6F
115V-60Hz
1PH
THERMALLY
PROTECTED
8322-4
Application
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
25.2
2.8/3.2
Approvals
UL984/CSA-C22.2
A B
Dimensions
0.75"(19)
Height
6.81 (173)
6.65 (169)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
July 2003
72
in. (mm) A
pcs.
125
CG.42.R2.22
CK.40.A5.22
(29)
31.5
28
6.50"(165)
0.63"(16)
0.14"(3.6)
5.35"(136)
14.4
4.13"(105)
4.21"(107)
30
200
8368
8.90"(226)
6.93"(176)
4.13"(105)
watt
3.78"(96)
4.61"(117)
2.76"(70)
Motor
LRA (rated after 4 sec.UL984) LST
1.14"
17.6 (8.0)
4.02"(102)
Motor size
2.80"(71)
51 20
6.18"(157)
60.7 (1790)
lbs. (kg)
4.00"(101.6)
fl.oz. (cm3)
2.34"(59.5)
2.60" (66)
45
0.35 (5.70)
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TTY6F
-30
-34.4
294
-20
-28.9
437
Btu/h
-13
-25
555
-10
-23.3
611
0
-17.8
825
10
-12.2
1084
14
-10
1202
-34.4
-30
70
-28.9
-20
105
-25
-13
133
watt
-23.3
-10
146
-17.8
0
197
-12.2
10
259
8233
-10
14
287
a1
Power consumption
Comp.\F
Comp.\C
TTY6F
-30
-34.4
91
watt
-20
-28.9
112
-13
-25
127
-10
-23.3
133
0
-17.8
154
10
-12.2
178
14
-10
189
-13
-25
1.29
-10
-23.3
1.34
0
-17.8
1.52
10
-12.2
1.73
14
-10
1.81
Current consumption
Comp.\F
Comp.\C
TTY6F
-30
-34.4
1.05
-20
-28.9
1.18
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TTY6F
-30
-34.4
3.21
Btu/Wh
-20
-28.9
3.88
-13
-25
4.39
-10
-23.3
4.61
0
-17.8
5.36
10
-12.2
6.09
14
-10
6.36
-23.3
-10
1.10
-17.8
0
1.28
-12.2
10
1.46
-10
14
1.52
-34.4
-30
0.77
-28.9
-20
0.93
-25
-13
1.05
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
TTY6F
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3303
TI-4TM414KFBYY-53
118-1946
118-1949
118-1947
CG.42.R2.22
CK.40.A5.22
July 2003
73
NTY5.5FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.S3.22)
General
NTY5.5FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NTY5.5FK
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5620
5620
Barcode on
white background
8330
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTY5.5FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8330-2
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.9 (290)
oz. (g)
14.0 (400)
23.8 (10.8)
4.45"(113)
20.4
3.1/4.0
Approvals
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
4.04"(102.5)
10.5
25
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
8.10"(205)
15
190
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
lbs. (kg)
27
51
2.13"
79.7 (2360)
3.35"(85)
fl.oz. (cm3)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.37 (6.13)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
74
CD.43.S4.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTY5.5FK
-30
-34.4
389
-20
-28.9
516
Btu/h
-13
-25
637
-10
-23.3
697
0
-17.8
938
10
-12.2
1247
14
-10
1391
-34.4
-30
93
-28.9
-20
122
-25
-13
151
watt
-23.3
-10
165
-17.8
0
222
-12.2
10
295
8233
-10
14
333
a1
Power consumption
Comp.\F
Comp.\C
NTY5.5FK
-30
-34.4
100
watt
-20
-28.9
118
-13
-25
132
-10
-23.3
139
0
-17.8
164
10
-12.2
193
14
-10
207
-13
-25
1.19
-10
-23.3
1.25
0
-17.8
1.47
10
-12.2
1.74
14
-10
1.86
Current consumption
Comp.\F
Comp.\C
NTY5.5FK
-30
-34.4
0.90
-20
-28.9
1.06
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTY5.5FK
-30
-34.4
3.91
Btu/Wh
-20
-28.9
4.39
-13
-25
4.82
-10
-23.3
5.02
0
-17.8
5.72
10
-12.2
6.45
14
-10
6.74
-23.3
-10
1.18
-17.8
0
1.35
-12.2
10
1.52
-10
14
1.61
-34.4
-30
0.93
-28.9
-20
1.04
-25
-13
1.14
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTY5.5FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3306
TI-4TM419KFBYY-53
118-1946
118-1949
118-1947
CD.43.S4.22
CK.40.A5.22
July 2003
75
NTY6FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.A1.22)
General
NTY6FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NTY6FK
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5621
5621
Barcode on
white background
8330-5
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTY6FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8330-6
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.9 (290)
oz. (g)
14.0 (400)
23.8 (10.8)
4.45"(113)
20.4
3.1/4.0
Approvals
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
4.04"(102.5)
10.5
25
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
8.10"(205)
15
190
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
lbs. (kg)
27
51
2.13"
79.7 (2360)
3.35"(85)
fl.oz. (cm3)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.40 (6.58)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
76
CH.43.A2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTY6FK
-30
-34.4
427
-20
-28.9
579
Btu/h
-13
-25
718
-10
-23.3
786
0
-17.8
1054
10
-12.2
1391
14
-10
1547
-34.4
-30
102
-28.9
-20
139
-25
-13
172
watt
-23.3
-10
188
-17.8
0
252
-12.2
10
333
8233
-10
14
370
a1
Power consumption
Comp.\F
Comp.\C
NTY6FK
-30
-34.4
108
watt
-20
-28.9
130
-13
-25
148
-10
-23.3
156
0
-17.8
183
10
-12.2
214
14
-10
227
-13
-25
1.32
-10
-23.3
1.39
0
-17.8
1.64
10
-12.2
1.90
14
-10
2.02
Current consumption
Comp.\F
Comp.\C
NTY6FK
-30
-34.4
0.94
-20
-28.9
1.16
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTY6FK
-30
-34.4
3.96
Btu/Wh
-20
-28.9
4.44
-13
-25
4.86
-10
-23.3
5.05
0
-17.8
5.75
10
-12.2
6.50
14
-10
6.80
-23.3
-10
1.21
-17.8
0
1.38
-12.2
10
1.55
-10
14
1.63
-34.4
-30
0.95
-28.9
-20
1.06
-25
-13
1.16
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTY6FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3306
TI-4TM419KFBYY-53
118-1946
118-1949
118-1947
CH.43.A2.22
CK.40.A5.22
July 2003
77
NTY7FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.T3.22)
General
NTY7FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NTY7FK
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5720
5720
Barcode on
white background
8330-3
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTY7FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F1
*run capacitor compulsory
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8330-4
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.9 (290)
oz. (g)
14.0 (400)
23.8 (10.8)
4.45"(113)
21.6
2.9/2.9
Approvals
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
4.04"(102.5)
11.2
25
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
8.10"(205)
15
190
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
lbs. (kg)
27
51
2.13"
79.7 (2360)
3.35"(85)
fl.oz. (cm3)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.44 (7.27)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
78
CD.43.T4.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTY7FK
-30
-34.4
491
-20
-28.9
657
Btu/h
-13
-25
810
-10
-23.3
885
0
-17.8
1184
10
-12.2
1564
14
-10
1740
-34.4
-30
118
-28.9
-20
158
-25
-13
194
watt
-23.3
-10
212
-17.8
0
284
-12.2
10
374
8233
-10
14
416
a1
Power consumption
Comp.\F
Comp.\C
NTY7FK
-30
-34.4
117
watt
-20
-28.9
142
-13
-25
160
-10
-23.3
169
0
-17.8
199
10
-12.2
235
14
-10
251
-13
-25
1.48
-10
-23.3
1.55
0
-17.8
1.84
10
-12.2
2.17
14
-10
2.31
Current consumption
Comp.\F
Comp.\C
NTY7FK
-30
-34.4
1.11
-20
-28.9
1.31
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTY7FK
-30
-34.4
4.20
Btu/Wh
-20
-28.9
4.64
-13
-25
5.05
-10
-23.3
5.25
0
-17.8
5.94
10
-12.2
6.66
14
-10
6.94
-23.3
-10
1.26
-17.8
0
1.42
-12.2
10
1.59
-10
14
1.66
-34.4
-30
1.01
-28.9
-20
1.11
-25
-13
1.21
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTY7FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3306
TI-4TM419KFBYY-53
118-1946
118-1949
118-1947
CD.43.T4.22
CK.40.A5.22
July 2003
79
NTY9FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.B1.22)
General
NTY9FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NTY9FK
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5921
5921
Barcode on
white background
8330-7
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTY9FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F1
*run capacitor compulsory
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8330-8
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.9 (290)
oz. (g)
14.0 (400)
23.8 (10.8)
4.45"(113)
24.2
2.4/3.2
Approvals
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
4.04"(102.5)
13.4
25
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
8.10"(205)
15
230
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
lbs. (kg)
27
51
2.13"
79.7 (2360)
3.35"(85)
fl.oz. (cm3)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.51 (8.35)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
80
CH.43.B2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTY9FK
-30
-34.4
557
-20
-28.9
753
Btu/h
-13
-25
930
-10
-23.3
1016
0
-17.8
1356
10
-12.2
1784
14
-10
1982
-34.4
-30
134
-28.9
-20
181
-25
-13
223
watt
-23.3
-10
243
-17.8
0
325
-12.2
10
427
8233
-10
14
474
a1
Power consumption
Comp.\F
Comp.\C
NTY9FK
-30
-34.4
135
watt
-20
-28.9
164
-13
-25
186
-10
-23.3
196
0
-17.8
231
10
-12.2
271
14
-10
290
-13
-25
1.67
-10
-23.3
1.75
0
-17.8
2.08
10
-12.2
2.45
14
-10
2.61
Current consumption
Comp.\F
Comp.\C
NTY9FK
-30
-34.4
1.26
-20
-28.9
1.48
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTY9FK
-30
-34.4
4.13
Btu/Wh
-20
-28.9
4.59
-13
-25
5.00
-10
-23.3
5.19
0
-17.8
5.87
10
-12.2
6.57
14
-10
6.84
-23.3
-10
1.24
-17.8
0
1.41
-12.2
10
1.57
-10
14
1.64
-34.4
-30
0.99
-28.9
-20
1.10
-25
-13
1.20
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTY9FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3310
TI-4TM789KDBZZ-53
118-1946
118-1949
118-1947
CH.43.B2.22
CK.40.A5.22
July 2003
81
NTY10FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.C1.22)
General
NTY10FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
105G
NTY10FK
Code number
Blue stripe
R134a
SUCTION
CONNECTOR
105G5922
5922
Barcode on
white background
8330-9
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTY10FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F1
*run capacitor compulsory
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8330-10
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.9 (290)
oz. (g)
14.0 (400)
23.8 (10.8)
4.45"(113)
30.7
1.8/3.1
Approvals
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
4.04"(102.5)
20.3
25
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
8.10"(205)
15
285
35
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
47
(54)
lbs. (kg)
27
51
2.13"
79.7 (2360)
3.35"(85)
fl.oz. (cm3)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.62 (10.09)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
82
CH.43.C2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTY10FK
-30
-34.4
635
-20
-28.9
873
Btu/h
-13
-25
1082
-10
-23.3
1183
0
-17.8
1581
10
-12.2
2085
14
-10
2321
-34.4
-30
152
-28.9
-20
209
-25
-13
259
watt
-23.3
-10
283
-17.8
0
378
-12.2
10
499
8233
-10
14
555
a1
Power consumption
Comp.\F
Comp.\C
NTY10FK
-30
-34.4
164
watt
-20
-28.9
200
-13
-25
226
-10
-23.3
238
0
-17.8
281
10
-12.2
331
14
-10
354
-13
-25
2.31
-10
-23.3
2.41
0
-17.8
2.78
10
-12.2
3.21
14
-10
3.41
Current consumption
Comp.\F
Comp.\C
NTY10FK
-30
-34.4
1.89
1
2
4
3
e
a1
-20
-28.9
2.12
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTY10FK
-30
-34.4
3.87
Btu/Wh
-20
-28.9
4.36
-13
-25
4.78
-10
-23.3
4.97
0
-17.8
5.63
10
-12.2
6.30
14
-10
6.56
-23.3
-10
1.19
-17.8
0
1.35
-12.2
10
1.51
-10
14
1.57
-34.4
-30
0.93
-28.9
-20
1.05
-25
-13
1.14
Motor protector
W/W
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTY10FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3311
TI-4TM805KDBZZ-53
118-1946
118-1949
118-1947
CH.43.C2.22
CK.40.A5.22
July 2003
83
NTX5.2FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.K2.22)
General
NTX5.2FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
Blue stripe
105G5650
105G
NTX5.2FK
Code number
R134a
SUCTION
CONNECTOR
5650
Barcode on
white background
8423
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTX5.2FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8423-2
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.2 (270)
oz. (g)
14.0 (400)
4.45"(113)
7.0
14.7
5.6/4.6
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
15
Approvals
C
35
4.04"(102.5)
8.10"(205)
25
124
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
(54)
24.9 (11.3)
lbs. (kg)
47
2.13"
27
51
3.35"(85)
79.5 (2340)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.31 (5.20)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
84
CH.43.K3.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTX5.2FK
-30
-34.4
277
Btu/h
-20
-28.9
424
-13
-25
543
-10
-23.3
600
0
-17.8
812
10
-12.2
1066
14
-10
1182
-34.4
-30
64.8
-28.9
-20
100
-25
-13
128
watt
-23.3
-10
142
-17.8
0
192
-12.2
10
252
8233
-10
14
279
a1
Power consumption
Comp.\F
Comp.\C
NTX5.2FK
-30
-34.4
71.1
watt
-20
-28.9
89.3
-13
-25
102
-10
-23.3
107
0
-17.8
125
10
-12.2
144
14
-10
152
-13
-25
0.89
-10
-23.3
0.94
0
-17.8
1.12
10
-12.2
1.30
14
-10
1.38
Current consumption
Comp.\F
Comp.\C
NTX5.2FK
-30
-34.4
0.62
-20
-28.9
0.78
1
2
4
3
e
a1
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTX5.2FK
-30
-34.4
3.89
Btu/Wh
-20
-28.9
4.74
-13
-25
5.34
-10
-23.3
5.60
0
-17.8
6.48
10
-12.2
7.40
-23.3
-10
1.32
-17.8
0
1.53
-12.2
10
1.75
-34.4
-30
0.92
-28.9
-20
1.12
-25
-13
1.26
14
-10
7.77
Motor protector
W/W
-10
14
1.83
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 12 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTX5.2FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7126
117U3302
TI-4TM314NFBYY-53
118-1946
118-1949
118-1947
CH.43.K3.22
CK.40.A5.22
July 2003
85
NTX5.7FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.L2.22)
General
NTX5.7FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
Blue stripe
105G5651
105G
NTX5.7FK
Code number
R134a
SUCTION
CONNECTOR
5651
Barcode on
white background
8423-3
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTX5.7FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8423-4
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.2 (270)
oz. (g)
14.0 (400)
4.45"(113)
10.9
21.2
2.8/3.5
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
15
Approvals
C
35
4.04"(102.5)
8.10"(205)
25
182
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
(54)
24.9 (11.3)
lbs. (kg)
47
2.13"
27
51
3.35"(85)
79.5 (2340)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.34 (5.71)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
86
CH.43.L3.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTX5.7FK
-30
-34.4
317
Btu/h
-20
-28.9
472
-13
-25
606
-10
-23.3
670
0
-17.8
919
10
-12.2
1226
14
-10
1367
-34.4
-30
74.6
-28.9
-20
111
-25
-13
143
watt
-23.3
-10
158
-17.8
0
218
-12.2
10
290
8233
-10
14
324
a1
Power consumption
Comp.\F
Comp.\C
NTX5.7FK
-30
-34.4
82.3
watt
-20
-28.9
98.6
-13
-25
112
-10
-23.3
118
0
-17.8
139
10
-12.2
162
14
-10
172
-13
-25
1.01
-10
-23.3
1.06
0
-17.8
1.24
10
-12.2
1.44
14
-10
1.52
Current consumption
Comp.\F
Comp.\C
NTX5.7FK
-30
-34.4
0.72
1
2
4
3
e
a1
-20
-28.9
0.88
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTX5.7FK
-30
-34.4
3.85
Btu/Wh
-20
-28.9
4.79
-13
-25
5.43
-10
-23.3
5.70
0
-17.8
6.61
10
-12.2
7.55
-23.3
-10
1.34
-17.8
0
1.56
-12.2
10
1.78
14
-10
7.93
-34.4
-30
0.91
-28.9
-20
1.13
-25
-13
1.28
Motor protector
W/W
-10
14
1.87
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTX5.7FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3312
TI-4TM319NFBYY-53
118-1946
118-1949
118-1947
CH.43.L3.22
CK.40.A5.22
July 2003
87
NTX7.3FK
High Energy-optimized Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.M2.22)
General
NTX7.3FK
Connector-material
Sealing
Copper-plated steel
Aluminium caps
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
Blue stripe
105G5750
105G
NTX7.3FK
Code number
R134a
SUCTION
CONNECTOR
5750
Barcode on
white background
8423-5
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP
NTX7.3FK
115V-60Hz
1PH
F (C)
Voltage range
V/Hz
Motor type
RSCR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
S
O
F1
F2
THERMALLY
PROTECTED
= Static cooling normally sufficient
Approval mark
= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary
8423-6
Application
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.2 (270)
oz. (g)
14.0 (400)
4.45"(113)
10.9
21.2
2.8/3.5
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
8.00 (203)
7.76 (197)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
15
Approvals
C
35
4.04"(102.5)
8.10"(205)
25
182
9.92"(252)
8.03"(204)
6.70"(170)
1.38"(35)
watt
4.69"(119)
5.00"(127)
3.68"(93.5)
Motor size
5.20"(132)
4.00"(101.6)
2.76"(70)
Motor
(54)
24.9 (11.3)
lbs. (kg)
47
2.13"
27
51
3.35"(85)
79.5 (2340)
2.97"(75.5)
6.54"(166)
2.83"(72)
2.34" (59.5)
0.44 (7.29)
8252
0.75"(19)
0.63"(16)
0.38"(9.7)
6.50"(165)
7.32"(186)
July 2003
88
CH.43.M3.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
NTX7.3FK
-30
-34.4
443
Btu/h
-20
-28.9
627
-13
-25
790
-10
-23.3
870
0
-17.8
1181
10
-12.2
1567
14
-10
1744
-34.4
-30
105
-28.9
-20
148
-25
-13
187
watt
-23.3
-10
206
-17.8
0
280
-12.2
10
371
8233
-10
14
413
a1
Power consumption
Comp.\F
Comp.\C
NTX7.3FK
-30
-34.4
103
watt
-20
-28.9
126
-13
-25
144
-10
-23.3
151
0
-17.8
178
10
-12.2
207
14
-10
219
-13
-25
1.28
-10
-23.3
1.35
0
-17.8
1.60
10
-12.2
1.87
14
-10
1.98
Current consumption
Comp.\F
Comp.\C
NTX7.3FK
-30
-34.4
0.93
1
2
4
3
e
a1
-20
-28.9
1.13
Start winding
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
NTX7.3FK
-30
-34.4
4.29
Btu/Wh
-20
-28.9
4.96
-13
-25
5.50
-10
-23.3
5.75
0
-17.8
6.63
10
-12.2
7.57
-23.3
-10
1.36
-17.8
0
1.56
-12.2
10
1.78
14
-10
7.95
-34.4
-30
1.02
-28.9
-20
1.17
-25
-13
1.30
Motor protector
W/W
-10
14
1.87
Test conditions
ASHRAE
EN 12900/CECOMAF
Condensing temperature
130F (54,4C) 55C (131F)
Ambient and suction gas temp.
90F (32C)
32C (90F)
Liquid temperature
90F (32C)
55C (131F)
Static cooling, with RC 15 F, 115V 60Hz, PTC consumption incl.
Accessories
Devices
PTC star ting device (Texas Instr.)
with reduced loss of energy
PTC star ting device (Siemens)
with reduced loss of energy
a1
NTX7.3FK
117U6102
TI 8EA 4B3
117U6106
a1
(alternative)
J506-A120-A320
Cover
117U1026
Mounting accessories
Bolt joint for one compressor
Bolt joint for one compressor
Snap-on for one compressor
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
July 2003
Fig.
117-7118
117U3312
TI-4TM319NFBYY-53
118-1946
118-1949
118-1947
CH.43.M3.22
CK.40.A5.22
July 2003
89
TFS4.5FT
Tropical Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CG.42.N1.22)
General
TFS4.5FT
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
102G3439
Copper-plated steel
Rubber plugs
Copper
Rubber plugs
Application
102G
TFS4.5FT
R134a
SUCTION
CONNECTOR
Blue stripe
102G3433
102G3436
3433
Barcode on
white background
DANFOSS COMPRESSORS
8320-3
Compressor
Green background
R
95 - 135 /60
Approval mark
110 (43)
110F (43C)
45
51 20
F (C)
6.18"(157)
4.02"(102)
C
0.29 (4.63)
Oil quantity
fl.oz. (cm3)
6.1 (180)
oz. (g)
14.0 (400)
fl.oz. (cm3)
60.7 (1790)
lbs. (kg)
A B
14.7 (6.7)
4.13"(105)
0.75"(19)
Motor
watt
160
20.1
3.3/8.8
Approvals
UL984/CSA-C22.2
Dimensions
102G3433
6.70"(170)
7.01"(178)
8.03"(204)
102G3436
in. (mm) A
6.81 (173)
6.65 (169)
102G3439
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
0.242-0.249 (6.20.09)
Discharge connector
0.252-0.259 (6.50.09)
0.202-0.205 (5.0+0.12/0.20)
Compressors on a pallet
July 2003
0.63"(16)
0.14"(3.6)
20.1
Height
6.50"(165)
2.76"(70)
Motor size
4.13"(105)
4.21"(107)
cu.in. (cm3)
8246
8.90"(226)
6.93"(176)
31.5
28
Displacement
3.78"(96)
4.61"(117)
30
Design
90
THERMALLY
PROTECTED
RSIR
2.34"(59.5)
2.60" (66)
Motor type
F2
8320-2
V/Hz
(29)
F (C)
5.35"(136)
TFS4.5FT
115V-60Hz
1PH
1.14"
LBP
2.80"(71)
Application
S
O
F1
4.00"(101.6)
Application
pcs.
0.242-0.249 (6.20.09)
125
CG.42.N2.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TFS4.5FT
-30
-34.4
245
-20
-28.9
340
Btu/h
-13
-25
431
-10
-23.3
477
0
-17.8
654
10
-12.2
875
14
-10
974
a2
-34.4
-30
58
-28.9
-20
80
watt
-25
-13
102
-23.3
-10
113
-17.8
0
155
-12.2
10
208
-13
-25
121
-10
-23.3
127
0
-17.8
148
10
-12.2
172
Power consumption
Comp.\F
Comp.\C
TFS4.5FT
-30
-34.4
90
-20
-28.9
108
-10
14
231
-30
-34.4
1.88
-20
-28.9
1.94
8230
watt
14
-10
182
Current consumption
Comp.\F
Comp.\C
TFS4.5FT
a2
A
-13
-25
1.99
-10
-23.3
2.02
0
-17.8
2.12
10
-12.2
2.25
14
-10
2.31
10
12
Main winding
EER (ASHRAE)
Comp.\F
Comp.\C
TFS4.5FT
-30
-34.4
2.72
-34.4
-30
0.64
Start winding
Thermostat
14
Btu/Wh
-20
-28.9
3.16
-13
-25
3.56
-10
-23.3
3.75
0
-17.8
4.40
10
-12.2
5.09
14
-10
5.36
-23.3
-10
0.89
-17.8
0
1.04
-12.2
10
1.21
-10
14
1.27
11
13
-28.9
-20
0.75
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 115V 60Hz
-25
-13
0.84
Motor protector
W/W
ASHRAE
130F (54,4C)
90F (32C)
90F (32C)
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
Texas Instruments
MRP39AIL-6
Cover
117U1021
Cord relief
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
July 2003
a2
TFS4.5FT
117U4113
in.
(mm)
/8 (16)
5
/8 (16)
5
/8 (16)
5
118-1917
118-1918
118-1919
CG.42.N2.22
CK.40.A5.22
July 2003
91
TFS4.5FT
Tropical Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.42.R6.22)
General
TFS4.5FT
Connector-material
Sealing
Code number
Copper-plated steel
Aluminium caps
102G3452
Copper-plated steel
Rubber plugs
102G3432
Copper
Rubber plugs
102G3438
102G
TFS4.5FT
Application
R134a
SUCTION
CONNECTOR
Blue stripe
3432
Barcode on
white background
8320
Compressor
DANFOSS COMPRESSORS
Green background
Application
LBP/MBP
S
O
F1
RSIR/CSIR*
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
F2
F1
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.5 (280)
oz. (g)
14.0 (400)
6.18"(157)
0.29 (4.63)
fl.oz. (cm3)
4.02"(102)
57.3 (1690)
lbs. (kg)
THERMALLY
PROTECTED
Approval mark
45
Design
110F (43C)
8320-2
Motor type
TFS4.5FT
115V-60Hz
1PH
3.78"(96)
4.61"(117)
(29)
95 - 135 /60
1.14"
V/Hz
51 20
F (C)
2.34"(59.5)
2.60" (66)
2.80"(71)
Application
8368
8.90"(226)
6.93"(176)
14.9 (6.8)
E
watt
160
20.1
A B
20.1
4.13"(105)
4.21"(107)
Motor size
4.13"(105)
30
31.5
28
Motor
3.3/8.8
Approvals
UL984/CSA-C22.2
0.75"(19)
6.50"(165)
0.63"(16)
6.81 (173)
6.65 (169)
Suction connector
0.252-0.259 (6.50.09)
0.252-0.259 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
Discharge connector
Compressors on a pallet
July 2003
92
in. (mm) A
pcs.
0.252-0.259 (6.50.09)
5.35"(136)
Height
102G3438
2.76"(70)
102G3452/32
4.00"(101.6)
0.14"(3.6)
Dimensions
6.70"(170)
7.01"(178)
8.03"(204)
125
CD.42.R7.22
CK.40.A5.22
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
TFS4.5FT
-30
-34.4
245
Btu/h
-20
-28.9
340
-13
-25
431
-10
-23.3
477
0
-17.8
654
10
-12.2
875
14
-10
974
20
-6.7
1135
30
-1.1
1445
40
4.4
1793
-34.4
-30
58
-28.9
-20
80
-25
-13
102
-30
-34.4
90
-23.3
-10
113
-17.8
0
155
-12.2
10
20 8
-10
14
231
-6.7
20
269
-1.1
30
343
4.4
40
425
-30
-34.4
1.88
-20
-28.9
108
-13
-25
121
-10
-23.3
127
0
-17.8
148
10
-12.2
172
14
-10
182
20
-6.7
197
30
-1.1
225
40
4.4
254
-30
-34.4
2.72
-20
-28.9
1.94
-13
-25
1.99
-10
-23.3
2.02
0
-17.8
2.12
10
-12.2
2.25
14
-10
2.31
20
-6.7
2.41
30
-1.1
2.60
40
4.4
2.83
-20
-28.9
3.16
-13
-25
3.56
-10
-23.3
3.75
0
-17.8
4.40
10
-12.2
5.09
14
-10
5.36
20
-6.7
5.76
30
-1.1
6.43
40
4.4
7.06
-34.4
-30
0.64
8230
45
7.2
270
a2
-23.3
-10
0.89
-17.8
0
1.04
-12.2
10
1.21
-10
14
1.27
-6.7
20
1.37
-1.1
30
1.52
4.4
40
1.67
45
7.2
2.96
10
12
11
13
-28.9
-20
0.75
-25
-13
0.84
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 115V 60Hz
45
7.2
7.37
Start winding
Thermostat
Main winding
14
Btu/Wh
EER (ASHRAE)
Comp.\F
Comp.\C
TFS4.5FT
7.2
45
471
watt
Current consumption
Comp.\F
Comp.\C
TFS4.5FT
a2
watt
Power consumption
Comp.\F
Comp.\C
TFS4.5FT
45
7.2
1987
Motor protector
(pos.1)
W/W
ASHRAE
130F (54,4C)
90F (32C)
90F (32C)
7.2
45
1.74
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
a2
8226
dc
Accessories
Devices
Star ting relay (protector incl.)
Protector 3/4"
Texas Instruments
Texas Instruments
Cover
TFS4.5FT
a2
(pos.1)
117U4113
a2
c
(pos.2)
b
a2
c
MRP39AIL-6
10
12
11
13
117U4126*
117U5022*
Main winding
Start winding
Thermostat
14
MRP39AIL-6
117U1021
Cord relief
117U0349
dc
117U0349
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
Fig.
CD.42.R7.22
CK.40.A5.22
(pos.2)
Motor protector
*In capillary tube systems where nonequalized pressures may occur at compressor start, or in areas with short power
supply drop-outs, a starting capacitor can
be used for ensuring a successful start
(CSIR).
July 2003
93
SC12FTX
Tropical Compressor
R134a
115-127V 60Hz
Data Sheet
General
Compressor (CU-plated steel connectors)
SC12FTX
Code number
104G7205
104G
SC12FTX
Application
R134a
Application
Evaporating temperature range
F (C)
Voltage range*)
V/Hz
LBP/MBP
Barcode on
white background
Green background
7205
DANFOSS COMPRESSORS
95 - 135 /60
CSIR
F (C)
SC12FTX
115V-60Hz
1PH
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
S
O
F1
F2
THERMALLY
PROTECTED
8452-2
Motor type
8452
Blue stripe
Application
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
20.3 (600)
oz. (g)
45.5 (1300)
49.4 (1460)
27.7 (12.6)
Motor
4.21"(107)
Motor size
watt
490
38.2
4.21"(107)
4.53"(115)
8.58"(218)
38.2
1.2/4.2
Approvals
UL984/CSA-C22.2
B A
B1
8.23 (209)
8.00 (203)
B1
7.20 (183)
B2
3.94 (100)
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
5"(127)
6.50"(165)
7.32"(186)
October 2001
94
0.75"(19)
0.38"(9.7)
0.320-0.327 (8.20.09)
Process connector
Compressors on a pallet
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
2.76"(70)
5.91"(150)
0.63"(16)
5"(127)
4"(101.6)
1.38"(35)
Suction connector
in. (mm) A
B2
0.12"(3)
Dimensions
Height
2.48"(63)
37
37
2.48"(63)
2.17"(55)
lbs. (kg)
5.94"(151)
2.17"(55)
0.78 (12.90)
CG.44.I1.22
CK.40.A5.22
8324
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
SC12FTX
-30
-34.4
563
-20
-28.9
889
Btu/h
-13
-25
1155
-10
-23.3
1280
0
-17.8
1753
10
-12.2
2324
14
-10
2583
20
-6.7
3008
-23.3
-10
303
-17.8
0
415
-12.2
10
549
-10
14
610
-6.7
20
710
-34.4
-30
132
-28.9
-20
210
-25
-13
273
watt
Power consumption
Comp.\F
Comp.\C
SC12FTX
-30
-34.4
244
-20
-28.9
302
-30
-34.4
5.01
-20
-28.9
5.28
b
8222
a2
watt
-13
-25
343
-10
-23.3
360
0
-17.8
419
10
-12.2
478
14
-10
502
20
-6.7
537
-13
-25
5.48
-10
-23.3
5.57
0
-17.8
5.88
10
-12.2
6.20
14
-10
6.34
20
-6.7
6.55
Current consumption
Comp.\F
Comp.\C
SC12FTX
c
11
10
12
13
14
EER (ASHRAE)
Comp.\F
Comp.\C
SC12FTX
-30
-34.4
2.30
Btu/Wh
-20
-28.9
2.94
-13
-25
3.37
-10
-23.3
3.55
0
-17.8
4.18
10
-12.2
4.86
14
-10
5.15
20
-6.7
5.60
Start winding
Main winding
Winding protector
-34.4
-30
0.54
-28.9
-20
0.70
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 115V 60Hz
-25
-13
0.80
W/W
-23.3
-10
0.84
ASHRAE
130F (54.4C)
90F (32C)
90F (32C)
-17.8
0
0.99
-12.2
10
1.15
-10
14
1.21
-6.7
20
1.32
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
SC12FTX
Starting relay
a2
117U6012
Cover
103N2008
117U5023
103N1004
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.44.I1.22
CK.40.A5.22
October 2001
95
SC15FTX
Tropical Compressor
R134a
115-127V 60Hz & 100V 50/60Hz
Data Sheet (Replaces CG.44.J1.22)
General
Compressor (CU-plated steel connectors)
SC15FTX
Code number
104G7505
104G
SC15FTX
Application
R134a
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/MBP
Barcode on
white background
Green background
7505
DANFOSS COMPRESSORS
8452-3
Blue stripe
Application
95 - 135 /60
90 - 110 /50
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
S
O
F1
F2
THERMALLY
PROTECTED
8452-4
SC15FTX
115V-60Hz
1PH
90 - 110 /60
Motor type
Approval mark
0.93 (15.30)
fl.oz. (cm3)
20.3 (600)
oz. (g)
45.5 (1300)
49.4 (1460)
27.7 (12.6)
lbs. (kg)
4.21"(107)
Motor
Motor size
watt
540
42
42
in. (mm) A
8.23 (209)
8.00 (203)
B1
7.20 (183)
B2
3.94 (100)
E
B A
B1
B2
0.63"(16)
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
0.252-0.259 (6.50.09)
0.252-0.259 (6.50.09)
96
0.38"(9.7)
80
5"(127)
6.50"(165)
7.32"(186)
November 2001
0.75"(19)
2.76"(70)
5.91"(150)
0.320-0.327 (8.20.09)
Discharge connector
pcs.
8.58"(218)
5"(127)
4"(101.6)
1.38"(35)
Process connector
Compressors on a pallet
4.21"(107)
4.53"(115)
0.12"(3)
UL984/CSA-C22.2
Dimensions
Suction connector
1.0/4.3
Approvals
Height
37
37
2.48"(63)
cu.in. (cm3)
Oil quantity
2.48"(63)
2.17"(55)
Displacement
5.94"(151)
2.17"(55)
Design
CG.44.J2.22
CK.40.A5.22
8324
July 2003
Capacity (ASHRAE)
Comp.\F
Comp.\C
SC15FTX
-30
-34.4
711
-20
-28.9
1094
Btu/h
-13
-25
1404
-10
-23.3
1550
0
-17.8
2096
10
-12.2
2750
14
-10
3046
20
-6.7
3531
-23.3
-10
367
-17.8
0
497
-12.2
10
652
-10
14
722
-6.7
20
836
-34.4
-30
167
-28.9
-20
258
-25
-13
332
watt
Power consumption
Comp.\F
Comp.\C
SC15FTX
-30
-34.4
237
-20
-28.9
325
-30
-34.4
4.82
-20
-28.9
5.27
b
8222
a2
watt
-13
-25
382
-10
-23.3
405
0
-17.8
481
10
-12.2
555
14
-10
585
20
-6.7
632
-13
-25
5.60
-10
-23.3
5.75
0
-17.8
6.26
10
-12.2
6.81
14
-10
7.03
20
-6.7
7.39
Current consumption
Comp.\F
Comp.\C
SC15FTX
c
11
10
12
13
14
EER (ASHRAE)
Comp.\F
Comp.\C
SC15FTX
-30
-34.4
3.00
Btu/Wh
-20
-28.9
3.37
-13
-25
3.68
-10
-23.3
3.83
0
-17.8
4.36
10
-12.2
4.95
14
-10
5.20
20
-6.7
5.58
Start winding
Main winding
Winding protector
-34.4
-30
0.72
-28.9
-20
0.80
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F2, 115V 60Hz
-25
-13
0.87
W/W
-23.3
-10
0.91
ASHRAE
130F (54.4C)
90F (32C)
90F (32C)
-17.8
0
1.03
-12.2
10
1.17
-10
14
1.23
-6.7
20
1.32
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Accessories
Devices
Fig.
SC15FTX
Starting relay
a2
117U6020
Cover
103N2008
117U5023
103N1004
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.44.J2.22
CK.40.A5.22
November 2001
97
TL2.5G
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.42.E4.22)
General
Sealing
Baseplate
small
102G3255
large
102G3257
Copper
large
Rubber plugs
Application
Code number
102G
TL2.5G
TL2.5G
R134a
Blue stripe
3255
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
Application
LBP/HBP
F (C)
Voltage range
V/Hz
Motor type
110 (43)
S
O
F1
F2
RSIR
F (C)
Comp. cooling at
max. ambient temperature
110F (43C)
TL2.5G
115V-60Hz
1PH
THERMALLY
PROTECTED
8312-2
Connector-material
8312
Compressor
Approval mark
14.7 (6.7)
Motor
4.02"(102)
105
7.0
16.0
E
30
5.3/4.9
UL984/CSA-C22.2
A B
Dimensions
in. (mm) A
6.42 (163)
6.26 (159)
0.75"(19)
0.35"(9)
Process connector
Discharge connector
Compressors on a pallet
pcs.
6.50"(165)
(35)
1.38"
Suction connector
2.76"(70)
Height
0.63"(16)
2.76"(70)
Approvals
31.5
28
D
C
125
3.94"(100)
or
8.74"(222)
6.93"(176)
4.13"(105)
watt
8402
3.78"(96)
4.61"(117)
4.13"(105)
Motor size
C or
D
5.35"(136)
lbs. (kg)
(29)
14.0 (400)
54.3 (1600)
1.14"
oz. (g)
fl.oz. (cm3)
45
6.18"(157)
2.80"(71)
9.5 (280)
4.21"(107)
0.16 (2.61)
fl.oz. (cm3)
4.00"(101.6)
cu.in. (cm3)
Oil quantity
51 20
Displacement
2.38"(60.5)
2.60" (66)
Design
0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
98
CD.42.E5.22
CK.40.A5.22
July 2003
-13
-25
170
-10
-23.3
190
0
-17.8
279
10
-12.2
402
Btu/h
20
-6.7
557
30
-1.1
746
40
4.4
969
45
7.2
1093
50
10
1226
30
-1.1
660
40
4.4
857
45
7.2
966
50
10
1083
-13
-25
150
-10
-23.3
169
0
-17.8
248
10
-12.2
356
Btu/h
20
-6.7
493
-25
-13
41
-23.3
-10
45
-17.8
0
67
-12.2
10
96
-13
-25
69
-10
-23.3
72
59
15
1312
-6.7
20
133
-1.1
30
178
4.4
40
231
7.2
45
260
10
50
291
-13
-25
1.22
-10
-23.3
1.23
-10
-23.3
2.66
0
-17.8
81
10
-12.2
91
20
-6.7
101
30
-1.1
113
40
4.4
124
45
7.2
131
50
10
137
59
15
149
0
-17.8
1.28
10
-12.2
1.34
20
-6.7
1.41
30
-1.1
1.48
40
4.4
1.56
45
7.2
1.60
50
10
1.64
59
15
1.73
-10
-23.3
2.36
20
-6.7
5.50
30
-1.1
6.63
40
4.4
7.79
45
7.2
8.36
50
10
8.94
0
-17.8
3.46
10
-12.2
4.43
-23.3
-10
0.64
0
-17.8
3.07
-17.8
0
0.83
Btu/Wh
59
15
9.97
Winding protector
Btu/Wh
10
-12.2
3.92
20
-6.7
4.87
30
-1.1
5.87
40
4.4
6.88
45
7.2
7.39
50
10
7.89
-12.2
10
1.06
-6.7
20
1.31
-1.1
30
1.58
4.4
40
1.85
7.2
45
1.99
10
50
2.12
a1
watt
8217-2
15
59
353
Current consumption
Comp.\F
Comp.\C
TL2.5G
watt
Power consumption
Comp.\F
Comp.\C
TL2.5G
59
15
1488
59
15
8.79
W/W
15
59
2.36
Accessories
Devices
Fig.
TL2.5G
a1
103N0003
103N2011
Cord relief
103N1010
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
July 2003
103N0023
Cover
CD.42.E5.22
CK.40.A5.22
Test conditions
1. Condensing temperature
2. Ambient & suction gas temp.
3. Liquid temperature
Static cooling , 115V 60Hz,
PTC consumption incl.
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
1.
55C (131F)
2.
32C (90F)
3.
55C (131F)
July 2003
99
TL4G
Universal Compressor
R134a
100-115V 50/60Hz
Data Sheet (Replaces CD.42.F4.22)
General
Sealing
Code number
Copper-plated steel
Aluminium caps
102G3460
Copper-plated steel
Rubber plugs
102G3462
Copper
Rubber plugs
102G
TL4G
TL4G
Connector-material
Application
R134a
Blue stripe
3460
Barcode on
white background
DANFOSS COMPRESSORS
Green background
Application
8313
Compressor
LBP/HBP
F (C)
Voltage range
V/Hz
90 - 127 /50,60
Motor type
RSIR/CSIR
V/F (C)
at Voltage
V/F (C)
S
O
F1
F2
110F (43C)
100F (38C)
TL4G
115V-60Hz
1PH
8313-2
Application
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
9.5 (280)
oz. (g)
14.0 (400)
(29)
1.14"
16.7 (7.5)
4.02"(102)
12.2/14.2
22.6/14.2
3.2/3.4
Approvals
UL984/CSA-C22.2
or
8.74"(222)
6.93"(176)
D
C
E
31.5
28
C or
D
A B
4.13"(105)
4.21"(107)
170
8261
30
watt
3.78"(96)
4.61"(117)
4.13"(105)
Motor
Motor size
2.80"(71)
6.18"(157)
54.3 (1600)
lbs. (kg)
51 20
fl.oz. (cm3)
2.38"(60.5)
2.60" (66)
45
0.23 (3.86)
Dimensions
6.65 (169)
Suction connector
Process connector
Discharge connector
Compressors on a pallet
pcs.
125
0.75"(19)
6.50"(165)
0.63"(16)
5.35"(136)
6.81 (173)
2.76"(70)
in. (mm) A
4.00"(101.6)
Height
0.14"(3.6)
6.70"(170)
7.01"(178)
8.03"(204)
July 2003
100
CD.42.F5.22
CK.40.A5.22
July 2003
-13
-25
272
-10
0
10
-23.3 -17.8 -12.2
306
441 612
Btu/h
20
-6.7
824
30
40
45
50
59
-1.1
4.4
7.2
10
15
1078 1380 1550 1733 2097
20
-6.7
729
30
-1.1
954
40
45
50
59
4.4
7.2
10
15
1220 1369 1530 1849
-6.7
20
197
-1.1
30
257
4.4
40
328
-13
-25
241
-10
0
10
-23.3 -17.8 -12.2
271
391 542
Btu/h
-25
-13
65
7.2
45
368
10
50
412
-13
-25
91
-10
0
10
-23.3 -17.8 -12.2
96
111 129
20
-6.7
147
30
-1.1
167
40
4.4
187
45
7.2
197
50
10
207
59
15
225
-13
-25
1.74
-10
0
10
-23.3 -17.8 -12.2
1.75 1.79 1.86
20
-6.7
1.96
30
-1.1
2.10
40
4.4
2.30
45
7.2
2.41
50
10
2.55
59
15
2.83
20
-6.7
5.60
30
-1.1
6.47
40
4.4
7.39
45
7.2
7.87
50
10
8.37
-13
-25
2.97
-13
-25
2.64
Btu/Wh
-10
0
10
-23.3 -17.8 -12.2
3.19 3.96 4.76
59
15
9.32
Btu/Wh
-10
0
10
-23.3 -17.8 -12.2
2.83 3.51 4.22
20
-6.7
4.95
30
-1.1
5.72
40
4.4
6.53
45
7.2
6.95
50
10
7.39
-6.7
20
1.33
-1.1
30
1.54
4.4
40
1.76
7.2
45
1.87
10
50
1.99
a1
watt
8217-2
15
59
497
Current consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
TL4G
1.69 1.72
watt
Power consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
TL4G
71
82
LST
HST
c
59
15
8.22
W/W
15
59
2.21
b
8219
a2
d
Fig.
Devices
TL4G
c
11
10
a1
July 2003
Winding protector
Accessories
103N0003
103N0023
a2
117U6003
117U5023
Cover
103N2011
Cord relief
103N1010
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
in. (mm)
5
/8 (16)
3
/4 (19)
5
/8 (16)
118-1946
118-1949
118-1947
Test conditions
1. Condensing temperature
2. Ambient & suction gas temp.
3. Liquid temperature
Static cooling , 115V 60Hz,
PTC consumption incl.
12
13
14
Main winding
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
1.
55C (131F)
2.
32C (90F)
3.
55C (131F)
CD.42.F5.22
CK.40.A5.22
July 2003
101
FF6GK
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.C4.22)
General
Compressor (CU-plated steel connectors)
FF6GK
Codenumber
103G5680
103G5690
103G
FF6GK
Application
R134a
Application
5680
Barcode on
white background
Application
LBP/HBP
F (C)
V/Hz
Motor type
FF6GK
115V-60Hz
1PH
RSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
O/F1
S
O
F1
F2
8316-2
DANFOSS COMPRESSORS
Green background
8316
Blue stripe
THERMALLY
PROTECTED
Approval mark
Design
lbs. (kg)
23.3 (10.6)
1.57
"(40)
32.0 (900)
47.3 (1400)
24
40
oz. (g)
fl.oz. (cm3)
40
6.14"(156)
2.17"(55)
2.34" (59.5)
(55)
13.5 (400)
2.17"
0.38 (6.24)
fl.oz. (cm3)
(32)
cu.in. (cm3)
Oil quantity
1.26"
Displacement
Motor
25.0
2.2/8.3
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
7.72 (196)
7.52 (191)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
25
Approvals
0.63"(16)
0.38"(9.7)
July 2003
102
CD.43.C5.22
CK.40.A5.22
30
9.84"(250)
10.67"(271)
8.03"(204)
7.01"(178)
5.00"(127)
6.50"(165)
6.69"(170)
7.32"(186)
4.02"(102)
5.12"(130)
C
E
7.87"(200)
1.34" (34)
25.0
F
0.75"(19)
1.38"(35)
4.90"(124.5)
5.02"(127.5)
5.00"(127)
5.91"(150)
4.82"(122.5)
30
205
5.00"(127)
watt
4.00"(101.6)
2.76"(70)
Motor size
8254
July 2003
-13
-25
358
-10
-23.3
415
0
-17.8
652
10
-12.2
959
Btu/h
20
-6.7
1338
30
-1.1
1788
40
4.4
2310
45
7.2
2599
50
10
2907
-13
-25
318
-10
-23.3
368
0
-17.8
57 8
10
-12.2
850
20
-6.7
1184
30
-1.1
1581
40
4.4
2042
45
7.2
2296
50
10
2566
-25
-13
86
-13
-25
123
-17.8
0
156
-12.2
10
22 9
-6.7
20
319
-1.1
30
42 6
4.4
40
55 0
7.2
45
618
-13
-25
1.94
-10
-23.3
132
0
-17.8
162
10
-12.2
191
20
-6.7
221
30
-1.1
25 1
40
4.4
28 0
45
7.2
295
-13
-25
2.92
-10
-23.3
1.99
0
-17.8
2.15
10
-12.2
2.34
20
-6.7
2.54
30
-1.1
2.76
40
4.4
2.99
45
7.2
3.11
-10
-23.3
3.16
10
-12.2
5.01
20
-6.7
6.05
30
-1.1
7.13
40
4.4
8.24
45
7.2
8.81
0
-17.8
3.58
10
-12.2
4.44
20
-6.7
5.35
30
-1.1
6.31
40
4.4
7.29
45
7.2
7.78
-17.8
0
0.96
-12.2
10
1.20
-6.7
20
1.44
-1.1
30
1.70
4.4
40
1.96
7.2
45
2.10
0
-17.8
4.04
-13
-25
2.59
-10
-23.3
2.80
-25
-13
0.70
10
12
50
10
3.24
Btu/Wh
-23.3
-10
0.76
11
13
Start winding
Thermostat
Main winding
14
(pos.1)
Motor protector
50
10
9.39
a2
Btu/Wh
a2
50
10
310
watt
8230
10
50
690
Current consumption
Comp.\F -20
Comp.\C -28.9
FF6GK
1.84
watt
-23.3
-10
99
Power consumption
Comp.\F -20
Comp.\C -28.9
FF6GK
101
a2
Btu/h
8231
50
10
8.29
W/W
10
50
2.23
a2
7
Accessories
L
2
Devices
Fig.
FF6GK
Texas Instr.
MRP38JL-6
a2
MRP40EL-6
b
d
(pos.1)
117U1021
117U0349
b
(pos.2)
117U1024
Main winding
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CD.43.C5.22
CK.40.A5.22
11
10
4
13
12
Start winding
5
14
M
6
117U4086
Cover (standard)
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Texas Instr.
117U4085
a2
Motor protector
(pos.2)
Test conditions
1. Condensing temperature
2. Ambient and suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
ASHRAE
EN 12900/CECOMAF
1. LBP 130F (54,4C) 55C (131F)
2.
90F (32C)
32C (90F)
3.
90F (32C)
55C (131F)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
July 2003
103
FF7.5GK
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.D1.22)
General
Compressor (CU-plated steel connectors)
FF7.5GK
Codenumber
103G5780
103G5790
103G
FF7.5GK
Application
R134a
Blue stripe
5780
Barcode on
white background
Application
LBP/HBP
F (C)
DANFOSS COMPRESSORS
Green background
V/Hz
Motor type
FF7.5GK
115V-60Hz
1PH
RSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
O/F1
S
O
F1
F2
8316-4
8316-3
Application
THERMALLY
PROTECTED
Approval mark
Design
lbs. (kg)
23.3 (10.6)
1.57
"(40)
32.0 (900)
47.3 (1400)
24
40
oz. (g)
fl.oz. (cm3)
40
6.14"(156)
2.17"(55)
2.34" (59.5)
(55)
13.5 (400)
2.17"
0.42 (6.93)
fl.oz. (cm3)
(32)
cu.in. (cm3)
Oil quantity
1.26"
Displacement
Motor
25.0
2.2/8.3
UL984/CSA-C22.2
Dimensions
Height
in. (mm) A
7.72 (196)
7.52 (191)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
Compressors on a pallet
pcs.
80
A B
25
Approvals
0.63"(16)
0.38"(9.7)
July 2003
104
CH.43.D2.22
CK.40.A5.22
30
9.84"(250)
10.67"(271)
8.03"(204)
7.01"(178)
5.00"(127)
6.50"(165)
6.69"(170)
7.32"(186)
4.02"(102)
5.12"(130)
C
E
7.87"(200)
1.34" (34)
25.0
F
0.75"(19)
1.38"(35)
4.90"(124.5)
5.02"(127.5)
5.00"(127)
5.91"(150)
4.82"(122.5)
30
205
5.00"(127)
watt
4.00"(101.6)
2.76"(70)
Motor size
8254
July 2003
-13
-25
452
-10
-23.3
516
0
-17.8
777
10
-12.2
1111
Btu/h
20
-6.7
1518
30
-1.1
2000
40
4.4
255 6
45
7.2
286 3
50
10
3189
-13
-25
401
-10
-23.3
458
0
-17.8
689
10
-12.2
984
20
-6.7
1344
30
-1.1
1769
40
4.4
2259
45
7.2
2529
50
10
2816
-25
-13
108
-13
-25
138
-17.8
0
18 6
-12.2
10
265
-6.7
20
362
-1.1
30
47 7
4.4
40
60 8
7.2
45
68 1
-13
-25
2.02
-10
-23.3
148
0
-17.8
182
10
-12.2
216
20
-6.7
250
30
-1.1
28 6
40
4.4
322
45
7.2
34 0
-13
-25
3.28
-10
-23.3
2.07
0
-17.8
2.28
10
-12.2
2.51
20
-6.7
2.76
30
-1.1
3.03
40
4.4
3.32
45
7.2
3.47
-10
-23.3
3.49
10
-12.2
5.15
20
-6.7
6.06
30
-1.1
7.00
40
4.4
7.94
45
7.2
8.41
0
-17.8
3.79
10
-12.2
4.56
20
-6.7
5.37
30
-1.1
6.19
40
4.4
7.02
45
7.2
7.43
-17.8
0
1.02
-12.2
10
1.23
-6.7
20
1.45
-1.1
30
1.67
4.4
40
1.89
7.2
45
2.00
0
-17.8
4.27
-13
-25
2.91
-10
-23.3
3.09
50
10
3.62
Btu/Wh
-25
-13
0.78
-23.3
-10
0.83
10
12
11
13
Start winding
Thermostat
Main winding
14
(pos.1)
Motor protector
50
10
8.88
a2
Btu/Wh
a2
50
10
359
watt
8230
10
50
757
Current consumption
Comp.\F -20
Comp.\C -28.9
FF7.5GK 1.90
watt
-23.3
-10
123
Power consumption
Comp.\F -20
Comp.\C -28.9
FF7.5GK
115
a2
Btu/h
8231
50
10
7.84
W/W
10
50
2.11
a2
7
Accessories
L
2
Devices
Fig.
FF7.5GK
Texas Instr.
MRP38JL-6
a2
MRP40EL-6
b
d
(pos.1)
117U1021
117U0349
b
(pos.2)
117U1024
Main winding
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CH.43.D2.22
CK.40.A5.22
11
10
4
13
12
Start winding
5
14
M
6
117U4086
Cover (standard)
Cord relief
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Texas Instr.
117U4085
a2
Motor protector
(pos.2)
Test conditions
1. Condensing temperature
2. Ambient and suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
ASHRAE
EN 12900/CECOMAF
1. LBP 130F (54,4C) 55C (131F)
2.
90F (32C)
32C (90F)
3.
90F (32C)
55C (131F)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
July 2003
105
FF8.5GX
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.43.D4.22)
General
Compressor (CU-plated steel connectors)
FF8.5GX
Codenumber
103G
FF8.5GX
Application
103G5880
R134a
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/HBP
Barcode on
white background
Green background
5880
DANFOSS COMPRESSORS
F (C)
FF8.5GX
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F1
S
O
F1
F2
8317-2
Motor type
8317
Blue stripe
Application
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
13.5 (400)
oz. (g)
32.0 (900)
watt
310
28.0
28.0
4.82"(122.5)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
106
(55)
(32)
9.84"(250)
0.63"(16)
0.38"(9.7)
July 2003
CD.43.D5.22
CK.40.A5.22
4.02"(102)
5.12"(130)
7.52 (191)
8.03"(204)
7.01"(178)
0.75"(19)
1.38"(35)
7.72 (196)
4.00"(101.6)
2.76"(70)
in. (mm) A
25
A B
30
UL984/CSA-C22.2
Dimensions
Compressors on a pallet
C
E
7.87"(200)
1.9/6.6
Approvals
Height
4.90"(124.5)
5.02"(127.5)
5.00"(127)
6.50"(165)
6.69"(170)
7.32"(186)
5.00"(127)
5.91"(150)
Motor size
2.17"
Motor
24
1.26"
23.3 (10.6)
40
47.3 (1400)
lbs. (kg)
40
fl.oz. (cm3)
30
6.14"(156)
2.17"(55)
2.34" (59.5)
5.00"(127)
0.48 (7.95)
8255
July 2003
-13
-25
588
-10
-23.3
662
0
-17.8
957
10
-12.2
1328
Btu/h
20
-6.7
1773
30
-1.1
2294
40
4.4
2890
45
7.2
3217
20
-6.7
1570
30
-1.1
2029
40
4.4
2555
45
7.2
2842
-13
-25
522
-10
-23.3
587
0
-17.8
848
10
-12.2
1176
50
10
3563
Btu/h
50
10
3146
a2
8232
-25
-13
141
-23.3
-10
158
-17.8
0
229
watt
-12.2
10
317
-6.7
20
423
-1.1
30
547
4.4
40
688
7.2
45
765
10
50
846
Power consumption
Comp.\F -20
Comp.\C -28.9
FF8.5GX 172
-13
-25
198
-13
-25
3.22
b
a2
watt
-10
-23.3
209
0
-17.8
245
10
-12.2
283
20
-6.7
321
30
-1.1
359
40
4.4
398
45
7.2
418
50
10
437
Current consumption
Comp.\F -20
Comp.\C -28.9
FF8.5GX 3.13
dc
10
12
Main winding
A
-10
-23.3
3.27
0
-17.8
3.45
10
-12.2
3.67
20
-6.7
3.92
30
-1.1
4.19
40
4.4
4.46
45
7.2
4.59
Start winding
11
13
Thermostat
14
50
10
4.72
Motor protector
-13
-25
2.98
-10
-23.3
3.18
0
-17.8
3.90
Btu/Wh
10
-12.2
4.69
20
-6.7
5.53
30
-1.1
6.38
40
4.4
7.26
45
7.2
7.70
0
-17.8
3.46
10
-12.2
4.16
20
-6.7
4.89
30
-1.1
5.65
40
4.4
6.41
45
7.2
6.80
-17.8
0
0.93
-12.2
10
1.12
-6.7
20
1.32
-1.1
30
1.52
4.4
40
1.73
7.2
45
1.83
-13
-25
2.64
-10
-23.3
2.81
Btu/Wh
-25
-13
0.71
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
-23.3
-10
0.76
50
10
8.14
50
10
7.19
W/W Accessories
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (HBP)
130F (54.4C)
95F (35C)
115F (46C)
10
50
1.93
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Devices
Fig.
Texas Instr.
July 2003
CD.43.D5.22
CK.40.A5.22
MRP36AEN-6
Cover
117U1021
117U5041
Cord relief
117U0349
dc
117U0349
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
a2
FF8.5GX
117U4060
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
107
FF10GX
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CH.43.E1.22)
General
Compressor (CU-plated steel connectors)
FF10GX
Codenumber compressor
103G
FF10GX
Application
103G5980
R134a
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/HBP
Barcode on
white background
Green background
5980
DANFOSS COMPRESSORS
F (C)
FF10GX
115V-60Hz
1PH
110 (43)
Comp. cooling at
110F (43C)
F1
S
O
F1
F2
8317-4
Motor type
8317-3
Blue stripe
Application
THERMALLY
PROTECTED
Approval mark
Design
Displacement
cu.in. (cm3)
Oil quantity
fl.oz. (cm3)
13.5 (400)
oz. (g)
32.0 (900)
watt
330
29.9
29.9
4.82"(122.5)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
pcs.
80
108
(55)
(32)
9.84"(250)
0.63"(16)
0.38"(9.7)
July 2003
CH.43.E2.22
CK.40.A5.22
4.02"(102)
5.12"(130)
7.52 (191)
8.03"(204)
7.01"(178)
0.75"(19)
1.38"(35)
7.72 (196)
4.00"(101.6)
2.76"(70)
in. (mm) A
25
A B
30
UL984/CSA-C22.2
Dimensions
Compressors on a pallet
C
E
7.87"(200)
1.7/5.4
Approvals
Height
4.90"(124.5)
5.02"(127.5)
5.00"(127)
6.50"(165)
6.69"(170)
7.32"(186)
5.00"(127)
5.91"(150)
Motor size
2.17"
Motor
24
1.26"
23.3 (10.6)
40
47.3 (1400)
lbs. (kg)
40
fl.oz. (cm3)
30
6.14"(156)
2.17"(55)
2.34" (59.5)
5.00"(127)
0.55 (9.05)
8255
July 2003
-13
-25
635
-10
-23.3
716
0
-17.8
1041
10
-12.2
1450
Btu/h
20
-6.7
1945
30
-1.1
2526
40
4.4
3194
45
7.2
3562
20
-6.7
1721
30
-1.1
2234
40
4.4
2823
45
7.2
3147
-13
-25
563
-10
-23.3
635
0
-17.8
923
10
-12.2
1285
50
10
3953
Btu/h
50
10
3490
a2
8232
-25
-13
152
-23.3
-10
171
-17.8
0
249
watt
-12.2
10
346
-6.7
20
464
-1.1
30
602
4.4
40
760
7.2
45
847
10
50
939
Power consumption
Comp.\F -20
Comp.\C -28.9
FF10GX
19 1
-13
-25
220
-13
-25
3.61
b
a2
watt
-10
-23.3
232
0
-17.8
274
10
-12.2
316
20
-6.7
359
30
-1.1
402
40
4.4
446
45
7.2
468
50
10
491
Current consumption
Comp.\F -20
Comp.\C -28.9
FF10GX
3.50
dc
10
12
-10
-23.3
3.66
0
-17.8
3.86
10
-12.2
4.10
20
-6.7
4.37
30
-1.1
4.67
40
4.4
5.00
45
7.2
5.17
Thermostat
Main winding
Start winding
11
13
14
50
10
5.34
Motor protector
-13
-25
2.89
-10
-23.3
3.09
0
-17.8
3.80
Btu/Wh
10
-12.2
4.59
20
-6.7
5.42
30
-1.1
6.28
40
4.4
7.16
45
7.2
7.61
0
-17.8
3.37
10
-12.2
4.06
20
-6.7
4.80
30
-1.1
5.55
40
4.4
6.33
45
7.2
6.72
-17.8
0
0.91
-12.2
10
1.10
-6.7
20
1.29
-1.1
30
1.50
4.4
40
1.70
7.2
45
1.81
-13
-25
2.56
-10
-23.3
2.74
Btu/Wh
-25
-13
0.69
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Fan cooling F1, 115V 60Hz
-23.3
-10
0.74
50
10
8.06
50
10
7.11
W/W Accessories
ASHRAE (LBP)
130F (54.4C)
90F (32C)
90F (32C)
ASHRAE (HBP)
130F (54.4C)
95F (35C)
115F (46C)
10
50
1.91
EN12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
Devices
Fig.
a2
MRP30AEN-6
117U1021
117U5040
Cord relief
117U0349
dc
117U0349
Protector 3/4"
Electrica
Cover
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
CH.43.E2.22
CK.40.A5.22
FF10GX
117U4061
T 0772/06
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
July 2003
109
SC12G
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CD.44.A4.22)
General
Compressor (CU-plated steel connectors)
SC12G
Codenumber
104G7250
104G7260
104G
SC12G
Application
R134a
Application
7250
Barcode on
white background
Application
LBP/HBP
F (C)
V/Hz
Motor type
SC12G
115V-60Hz
1PH
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
O/F1
S
O
F1
F2
THERMALLY
PROTECTED
8319-2
DANFOSS COMPRESSORS
Green background
8319
Blue stripe
Approval mark
0.78 (12.90)
fl.oz. (cm3)
20.3 (600)
oz. (g)
45.5 (1300)
49.4 (1460)
27.7 (12.6)
lbs. (kg)
Motor
Motor size
watt
540
42.0
42.0
4.21"(107)
UL984/CSA-C22.2
B A
8.00 (203)
B1
7.20 (183)
B2
3.94 (100)
Suction connector
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
pcs.
(15)
0.63"(16)
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
F
0.75"(19)
0.38"(9.7)
80
5"(127)
6.50"(165)
7.32"(186)
110
B2
2.76"(70)
5.91"(150)
8.23 (209)
0.59"
(30)
0.12"(3)
in. (mm) A
1.18"
5"(127)
4"(101.6)
1.38"(35)
Dimensions
June 2003
8.58"(218)
B1
Compressors on a pallet
4.21"(107)
4.53"(115)
1.0/4.3
Approvals
Height
37
37
2.48"(63)
cu.in. (cm3)
Oil quantity
2.48"(63)
2.17"(55)
Displacement
5.94"(151)
2.17"(55)
Design
CD.44.A5.22
CK.40.A5.22
8256
July 2003
-13
-25
833
Btu/h
-10
0
10
20
30
40
45
50
-23.3 -17.8 -12.2 -6.7
-1.1
4.4
7.2
10
972 1507 2157 2924 3807 4808 5354 5930
-13
-25
739
-10
0
10
20
30
40
45
50
-23.3 -17.8 -12.2 -6.7
-1.1
4.4
7.2
10
861 1335 1911 2588 3367 4250 4730 5236
-6.7
20
698
-1.1
30
907
8222
-13
-25
252
-10
0
10
-23.3 -17.8 -12.2
269
328
389
20
-6.7
451
30
-1.1
516
40
4.4
581
45
7.2
615
50
10
649
-13
-25
4.70
-10
0
10
-23.3 -17.8 -12.2
4.76 5.01 5.31
20
-6.7
5.66
30
-1.1
6.05
40
4.4
6.49
45
7.2
6.72
50
10
6.97
a2
4.4
7.2
10
40
45
50
1144 1273 1409
watt
Current consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC12G
4.42 4.56
watt
-25
-13
199
Power consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC12G
157 212
Btu/h
c
11
10
12
13
14
Start winding
Btu/Wh
-13
-10
0
10
-25 -23.3 -17.8 -12.2
3.31 3.61 4.59 5.55
20
-6.7
6.48
30
-1.1
7.38
40
4.4
8.27
45
7.2
8.71
-10
0
10
-23.3 -17.8 -12.2
3.20 4.07 4.91
20
-6.7
5.73
30
-1.1
6.53
40
4.4
7.31
45
7.2
7.69
-6.7
20
1.55
-1.1
30
1.76
4.4
40
1.97
7.2
45
2.07
-13
-25
2.93
-25
-13
0.79
Winding protector
Btu/Wh
50
10
9.14
Main winding
50
10
8.07
W/W
10
50
2.17
Accessories
Devices
Fig.
SC12G
a2
117U6020
Cover
103N2008
117U5023
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CD.44.A5.22
CK.40.A5.22
Test conditions
1. Condensing temperature
2. Ambient and suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
ASHRAE
EN 12900/CECOMAF
1. LBP 130F (54,4C) 55C (131F)
2.
90F (32C)
32C (90F)
3.
90F (32C)
55C (131F)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
June 2003
111
SC15G
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.44.A1.22)
General
Compressor (CU-plated steel connectors)
SC15G
Codenumber
104G7550
104G7560
104G
SC15G
Application
R134a
Blue stripe
7550
Barcode on
white background
Application
LBP/HBP
F (C)
DANFOSS COMPRESSORS
Green background
SC15G
115V-60Hz
1PH
CSIR
F (C)
110 (43)
Comp. cooling at
110F (43C)
O/F1
S
O
F1
F2
Design
Displacement
cu.in. (cm3)
0.93 (15.30)
Oil quantity
fl.oz. (cm3)
20.3 (600)
oz. (g)
45.5 (1300)
49.4 (1460)
27.7 (12.6)
lbs. (kg)
Motor
Motor size
watt
540
42.0
42.0
5.94"(151)
2.17"(55)
4.21"(107)
E
B A
8.00 (203)
B1
7.20 (183)
B2
3.94 (100)
0.320-0.327 (8.20.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
0.252-0.259 (6.50.09)
Oil cooler
0.252-0.259 (6.50.09)
pcs.
(15)
0.63"(16)
10.04"(255)
8.03"(204)
7.01"(178)
6.69"(170)
F
0.75"(19)
0.38"(9.7)
80
5"(127)
6.50"(165)
7.32"(186)
112
B2
2.76"(70)
5.91"(150)
0.59"
(30)
0.12"(3)
8.23 (209)
1.18"
5"(127)
4"(101.6)
1.38"(35)
in. (mm) A
Suction connector
June 2003
UL984/CSA-C22.2
Dimensions
Compressors on a pallet
4.21"(107)
4.53"(115)
8.58"(218)
B1
Height
Approval mark
37
37
1.0/4.3
Approvals
THERMALLY
PROTECTED
8319-4
Motor type
2.48"(63)
V/Hz
2.48"(63)
2.17"(55)
8319-3
Application
CG.44.A2.22
CK.40.A5.22
8256
July 2003
Btu/h
Comp.\F -30
-20
-13
-10
0
10
20
30
40
45
50
Comp.\C -34.4 -28.9 -25 -23.3 -17.8 -12.2 -6.7
-1.1
4.4
7.2
10
SC15G
455
780 1088 1241 1837 2570 3440 4448 5595 6222 6884
-13
-25
965
-10
0
10
20
30
40
45
50
-23.3 -17.8 -12.2 -6.7
-1.1
4.4
7.2
10
1100 1628 2276 3045 3934 4945 5496 6078
-6.7
20
821
-1.1
30
1060
4.4
7.2
10
40
45
50
1331 1479 1635
-13
-25
306
-10
0
10
-23.3 -17.8 -12.2
329 408
486
20
-6.7
566
30
-1.1
645
40
4.4
726
45
7.2
766
8222
50
10
807
-13
-10
0
10
-25 -23.3 -17.8 -12.2
4.91 5.02 5.40 5.85
20
-6.7
6.35
30
-1.1
6.91
40
4.4
7.52
45
7.2
7.84
50
10
8.18
a2
d
watt
Current consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
4.45 4.70
watt
-25
-13
260
Power consumption
Comp.\F -30
-20
Comp.\C -34.4 -28.9
SC15G
175 252
Btu/h
c
11
10
12
13
14
Start winding
-13
-25
3.56
Btu/Wh
-10
0
10
-23.3 -17.8 -12.2
3.77 4.51 5.28
20
-6.7
6.08
30
-1.1
6.89
40
4.4
7.71
45
7.2
8.12
-10
0
10
-23.3 -17.8 -12.2
3.34 3.99 4.68
20
-6.7
5.38
30
-1.1
6.10
40
4.4
6.81
45
7.2
7.17
-6.7
20
1.45
-1.1
30
1.64
4.4
40
1.83
7.2
45
1.93
-13
-25
3.15
-25
-13
0.85
Winding protector
Btu/Wh
50
10
8.53
Main winding
50
10
7.54
W/W
10
50
2.03
Accessories
Devices
Fig.
SC15G
a2
117U6020
Cover
103N2008
117U5023
Cord relief
103N1004
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
118-1917
118-1918
118-1919
CG.44.A2.22
CK.40.A5.22
Test conditions
1. Condensing temperature
2. Ambient and suction gas temp.
3. Liquid temperature
Fan cooling F1, 115V 60Hz
ASHRAE
EN 12900/CECOMAF
1. LBP 130F (54,4C) 55C (131F)
2.
90F (32C)
32C (90F)
3.
90F (32C)
55C (131F)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
June 2003
113
SC18G
Universal Compressor
R134a
115V 60Hz
Data Sheet (Replaces CG.42.H2.22)
General
Compressor (CU-plated steel connectors)
SC18G
Codenumber
104G
SC18G
Application
104G7800
R134a
Application
Evaporating temperature range
F (C)
Voltage range
V/Hz
LBP/HBP
Barcode on
white background
Green background
7800
DANFOSS COMPRESSORS
8319-5
Blue stripe
Application
CSIR
F (C)
110 (43)
Comp. cooling at
max. ambient temperature
110F (43C)
F2
S
O
F1
F2
8319-6
SC18G
115V-60Hz
1PH
THERMALLY
PROTECTED
Approval mark
Design
cu.in. (cm3)
1.08 (17.69)
fl.oz. (cm3)
45.5 (1300)
49.4 (1460)
30.2 (13.7)
lbs. (kg)
37
37
4.21"(107)
Motor
Motor size
watt
755
53.0
53.0
4.21"(107)
4.53"(115)
E
B A
B1
B2
0.12"(3)
UL984/CSA-C22.2
8.62 (219)
8.39 (213)
B1
7.60 (193)
B2
4.33 (110)
Suction connector
Process connector
Discharge connector
0.252-0.259 (6.50.09)
0.63"(16)
10.43"(265)
8.03"(204)
7.01"(178)
6.69"(170)
114
0.38"(9.7)
60
5"(127)
6.50"(165)
7.32"(186)
June 2003
0.75"(19)
2.76"(70)
5.91"(150)
in. (mm) A
5"(127)
4"(101.6)
1.38"(35)
Dimensions
Compressors on a pallet
8.58"(218)
0.7/2.9
Approvals
Height
2.48"(63)
20.3 (600)
oz. (g)
2.34" (59.5)
2.17"(55)
Oil quantity
5.94"(151)
2.17"(55)
Displacement
CG.44.H3.22
CK.40.A5.22
8432
July 2003
-10
-23.3
1357
0
-17.8
2112
10
-12.2
2952
Btu/h
20
-6.7
3908
30
-1.1
5008
40
4.4
6285
45
7.2
6999
50
10
776 8
59
15
9308
-10
-23.3
1206
0
-17.8
1877
10
-12.2
2622
Btu/h
20
-6.7
3469
30
-1.1
4443
40
4.4
5570
45
7.2
6200
50
10
6878
59
15
8233
-25
-13
264
-23.3
-10
315
-17.8
0
495
-12.2
10
695
watt
-6.7
20
92 1
-1.1
30
1181
4.4
40
1481
7.2
45
1648
10
50
1829
-13
-25
374
-10
-23.3
404
watt
0
-17.8
504
10
-12.2
599
20
-6.7
691
30
-1.1
780
40
4.4
868
45
7.2
91 2
50
10
95 6
59
15
1035
Current consumption
Comp.\F
Comp.\C
SC18G
-13
-25
6.56
-10
-23.3
6.71
A
0
-17.8
7.24
10
-12.2
7.80
20
-6.7
8.41
30
-1.1
9.05
40
4.4
9.72
45
7.2
10.07
50
10
10.43
-13
-25
3.06
-10
-23.3
3.35
0
-17.8
4.19
10
-12.2
4.93
-13
-25
2.72
-10
-23.3
2.98
0
-17.8
3.73
20
-6.7
5.66
30
-1.1
6.42
40
4.4
7.24
45
7.2
7.67
50
10
8.13
-25
-13
0.71
-23.3
-10
0.79
-17.8
0
0.99
59
15
11.11
a2
b
a2
Start winding
10
-12.2
4.38
20
-6.7
5.02
30
-1.1
5.70
40
4.4
6.42
45
7.2
6.80
50
10
7.20
-12.2
10
1.16
-6.7
20
1.34
-1.1
30
1.51
4.4
40
1.70
7.2
45
1.80
10
50
1.91
c
Main winding
R
Thermostat
Motor protector
M
59
15
8.99
Btu/Wh
Btu/Wh
8433
15
59
2187
Power consumption
Comp.\F
Comp.\C
SC18G
59
15
7.95
W/W
15
59
2.11
Accessories
Devices
SC18G
a2
117-7441
117U5028
Cover
Protector
Protector holder
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap-on in quantities
July 2003
Fig.
h
in. (mm)
5
/8 (16)
5
/8 (16)
5
/8 (16)
(117U1021)
par ts of
compressor
(117U3212)
(117U0438)
118-1917
118-1918
118-1919
CG.44.H3.22
CK.40.A5.22
Test conditions
1. Condensing temperature
2. Ambient and suction gas temp.
3. Liquid temperature
Fan cooling F2, 115V 60Hz
ASHRAE
1. LBP 130F (54,4C)
2.
90F (32C)
3.
90F (32C)
1. HBP 130F (54,4 C)
2.
95F (35C)
3.
115F (46C)
EN 12900/CECOMAF
55C (131F)
32C (90F)
55C (131F)
June 2003
115
Appliance Controls
For the regulation of refrigeration appliances and freezers Danfoss supply a CFCfree product range of electromechanical thermostats for refrigerators and
electromechanical thermostats for refrigerators and freezers produced according
to customer specification; Hermetic valves for refrigerator/freezer combinations
and for energy saving applications; Service thermostats for all refrigerating and
freezing appliances.
www.danfoss.com/compressors
CK.40.A5.22