NETSURE MCA Menu Tree (Sheet 1 of 2)


STARTUP SEQUENCE
133

NORMAL DISPLAY W/ ALARMS

MAIN ALARM MENU


2 3

SPEC NO. ###### MCA SWV ######## Initializing....## 11 SET ###V DEFAULTS MUST SET SYS = ###V LOADING ###V..## MUST SET SPEC NO. SET ###### @ ###V CHANGE SPEC...##
16

## ALARMS ACTIVE NOT RUNNING YET! .

ALARM EMERG STOP ALARM LVD ACTIVE


4

LVD ALARM MENU


22

LVD** ACTIVATED RECONNECT LVD ** ARE YOU SURE? +- 9 Local Lockout On 9 MAIN ALARM MENU NORMAL DISPLAY

134

ALARM SYS 50%BOD 1 ALM VERY LO VOLT 1,14 ALARM LO VOLTAGE 1,15 ALARM SYSTEM BOD ALARM LO FLOAT 1,15
1

23

24
1

134A

ALARM SYSTEM HV1 ALARM HIGH FLOAT 1,15 ALARM SYSTEM HV2 1 ALARM HI VOLTAGE 1,15 ALARM SUBSYS LV ALARM SUBSYS HV ALARM SYSTEM FA ALARM SUBSYS FA
1 1 1 1 1

25

INITIALIZATION MENU
135 136 137 138 139

9
12

CHECK SETPOINTS! FLOAT = ###.##V TEST/EQ = ###.##V SET HVS = ###.##V

10 11 12 13 14

PCU ALARM MENU


26 27 28

PCU DETAIL MENU


47 48 49 50 51 52 53 54 55 56 57
1 1

PCU ** FAILURE MAIN ALARM MENU NORMAL DISPLAY


TEMPERATURE ALARM MENU

PCU## EMERG STOP PCU## AC FAIL PCU## HI AC LINE PCU## FAN FAIL PCU## BRKR OFF PCU## HVS ACTIVE PCU## A/D FAIL PCU## CONVERTER PCU## HIGH TEMP. PCU## OPEN SENSE PCU## SWITCH OFF PCU## NO REPLY PCU ALARM MENU NORMAL DISPLAY

ALM SUBSYS MAJOR ALARM ALL AC OFF ALARM HI AC LINE


3 1

CURRLIM = #####A CURRLIM = #####MAX BATTLIM DISABLED BATTLIM = #####A SYS HV1 = ###.##V HI FLOAT = ###.##V
15

139A

15

ALM ## PCUs FAIL 3 ALARM MRFA 1,15 ALARM 1 RFA 2,15 NO PCUs FOUND 1 ALM PCU## SHARE ALM TEMP SENSOR ALM SYSTEM CURR ALM SUBSYS CURR ALM BAT CHG CURR ALM SUBSYS MINOR ALARM MCA/SHELF FUNCTION MENU NORMAL DISPLAY
13 1

28A 28B 28C 28D


1 2 2

TEMP SENSOR ** HI TEMP SENSOR ** LO MAIN ALARM MENU NORMAL DISPLAY


MCA ALARM MENU

140

15B 15A
15

141

SYS HV2 = ###.##V HI VOLTAGE = ###.##V SYS BOD = ###.##V LOW FLOAT = ###.##V

16
15

142

17 17A 18 19 20 21

29 30

MCA BOARD FAIL A/D INPUT FUSE


5

143

SYS 50% = ###.##V VERYLOVOLT = ###.## 14 LO VOLTAGE = ###.## 15 SYSCURR = #####A SUB HV = ###.##V SUB LV = ###.##V SUBCURR = #####A BAT CHG = #####A LVD ** = ##.#V LV RECON = ##.#V MANUAL RECONNECT ANALOG TC OFF TC CAL = ##.##V TempCmp Hardware DIGITAL TC OFF SLOPE = .###V/C TempCmp Hardware MAX W/T = ##.##V MIN W/T = ##.##V HI TEMP** = ###C HI TEMP** IS OFF LO TEMP** = ###C LO TEMP** IS OFF ****A PLACES = ## START THE SYSTEM NOTES:
1 2

31
2

NO SYSTEM VOLTS NO SUBSYS VOLTS

58 59 60

144 145 146 147 147A 148 149

32

33

NO SENSE VOLTS 2 SENSE VOLT ERROR SHUNT** NO REPLY SHUNT** BAD TYPE 2 BAT CL INHIBITED
2 2

34

NORMAL DISPLAY NO ALARMS


0

SYSTEM OK

34A

150

Major Alarm

150A

150B 150C 150D

150E 151 152

Minor Alarm 3 Minor Alarm = 1 PCU Major Alarm = >1 PCU 4 Minor Alarm = A or B Major Alarm = A and B 5 Minor Alarm = Sense Fuse Major Alarm = System Fuse 6 ## = Substitute appropriate number 8 7 ** = Scroll through appropriate numbers 8 8 Applies to all menu items 9 Applies to all "Adjustable Settings" 10 All "Adjustable Settings" indicate changeable parameter 11 Exit to menu item 0 or 1 if all PCU serial #s match 12 Exit to menu item 0 or 1 if some PCU serial #s match 13 All "Normal" menu items lead to item 0 or 1 14 MCA P/N 534878 Only

35

LVD** NO REPLY 1 LVD** EPROM FAIL 1 LVD** A/D FAILED 1 LVD** RELAY FAIL 1 LVD** NO MCA CMD 1 LVDs INHIBITED
2 2 2

36 37 38 38A 39 40

to Sheet 2

REMOTE NO REPLY DISPLAY NO REPLY TEMP** NO REPLY 1 MAIN ALARM MENU NORMAL DISPLAY

Color Code Initializing Measurements Adjustable Settings Normal Adjustment Menu Alarms Configuration Menu Function Calibration Menu

15 16

MCA P/N 534871 Only Press ACO/UP/DOWN simultaneously to reach this item.

Page 1 of 4
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Section 6022 Issue AA, May 16, 2008


from Sheet 1

A
FUNCTION MENU
41

NETSURE MCA Menu Tree (Sheet 2 of 2)


MEASUREMENT MENU
61 62 63 64 65

SYSTEM LOAD MENU


86 87 88

SYSTEM ###.##VDC SYS LOAD #####A PCU LOAD #####A SUBSYS ###.##VDC SUB LOAD #####A BAT CHG #####A BAT CHGCL #####A BAT DIS #####A T SENSOR** ###C FUNCTION MENU NORMAL DISPLAY

SYSLOAD** #####A MEASUREMENT MENU NORMAL DISPLAY

MEASUREMENT MENU SET TEST/EQ MODE SET FLOAT MODE TestEq Switch On ADJUSTMENT MENU

42

43 44 45 46

PCU LOAD MENU


89 90 91

65A

CONFIGURE MENU CALIBRATION MENU NORMAL DISPLAY


65B 66 67

PCU** LOAD #####A MEASUREMENT MENU NORMAL DISPLAY

CONFIGURE MENU
73

VERIFY INVENTORY SHARE ALARM OFF SHARE ALARM ON EMERG STOP OFF EMERG STOP ON REMOTE HVS OFF REMOTE HVS ON DISPLAY ROLL OFF DISPLAY ROLL ON SET PCU ON / OFF LO SPEED FAN OFF LO SPEED FAN ON NAG MINUTES = ## AUDIBLE NAG OFF TEST/EQ HRS = ## TEST/EQ MAN STOP END TEQ ##.##HRS AUTO EQ DISABLED AUTO EQ MUL = ## END AUTO ##.## HR RELAYTEST = ###SEC SET SPANISH TEXT FUNCTION MENU NORMAL DISPLAY
121 118 68 69 70 71 72

SUBSYSTEM LOAD MENU ADJUSTMENT MENU SYSTEM ADJUSTMENT MENU


95 96 97 92 93 94

SUBLOAD** #####A MEASUREMENT MENU NORMAL DISPLAY

73A

ADJUST SYSTEM ADJUST ALARMS ADJUST LVDs FUNCTION MENU

FLOAT = ###.##V TEST/EQ = ###.##V SET HVS = ###.##V CURR LIM = ####A CURRLIM = #####MAX BATTLIM DISABLED BATTLIM = #####A 100% CURR: ####A ADJUSTMENT MENU NORMAL DISPLAY

73B

73D 73C 74 74A

99

NORMAL DISPLAY
99A

BATTERY LOAD MENU


94A

100

BAT** CHG #####A BAT** DIS #####A MEASUREMENT MENU NORMAL DISPLAY

INVENTORY MENU

94B 94C

75

PCU** TYPE ####A PCU** TYPE ####+ NO PCUs FOUND VACANT ****A= ## ****A PLACES= ## SHUNT** TYPE SYS SHUNT ** TYPE SUB SHUNT ** TYPE BAT NO SHUNTS FOUND LVD** INSTALLED NO LVDs FOUND ANALOG TC FOUND T SENSOR ** INST NO TEMP SENSORS SUBSYS INSTALLED NO SUBSYS FOUND REMOTE INSTALLED REMOTE ACTIVE NO REMOTE FOUND UPDATE INVENTORY PLEASE WAIT... REPLACE ** PCUs? CONFIGURE MENU NORMAL DISPLAY SPEC NO. ######### MCA SWV ######## REM SWV ########

101 102

76

119

76A

ALARM ADJUSTMENT MENU


103

120

77 77A 78 79

SYS HV1 = ###.##V HI FLOAT = ###.##V

15

104

SYS HV2 = ###.##V HI VOLTAGE = ###.##V SYS BOD = ###.##V LO FLOAT = ###.##V
15

15

121A

105

122

106

SYS 50% = ###.##V VERYLOVOLT = ###.## 14 LO VOLTAGE = ###.##V 15 SYSCURR = #####A SUB HV = ###.##V SUB LV = ###.##V SUBCURR = #####A BAT CHG = #####A HI TEMP** = ###C HI TEMP** IS OFF LO TEMP** = ###C LO TEMP** IS OFF TEST RELAYS TESTING RELAY # Alarm(s) Active ADJUSTMENT MENU NORMAL DISPLAY
LVD ADJUSTMENT MENU

123

107 108 109 110 110A

124

125

CALIBRATION MENU
80 81 82

CAL SYS = ###.##V CAL SUB = ###.##V

126 127 128

110B

110C

RESTORE MFG CAL


129

83

ANALOG TC OFF TC CAL = ##.##V TempCmp Hardware DIGITAL TC OFF SLOPE = .###V/C TempCmp Hardware MAX W/T = ##.##V MIN W/T = ##.##V TCOMP ON SENSOR1 TCOMP ON AVERAGE TCOMP ON HIGHEST FUNCTION MENU NORMAL DISPLAY
131 132

111

PCU ENABLE MENU

112 113

83A

130

83B 83C

PCU** ON:SET OFF PCU** OFF:SET ON Energy Mgmt. On CONFIGURE MENU NORMAL DISPLAY

114 115 116 117

LVD ** = ##.#V LV RECON = ##.#V MANUAL RECONNECT ADJUSTMENT MENU NORMAL DISPLAY

83D

84 85

Page 2 of 4
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Section 6022 Issue AA, May 16, 2008


TASK KEY OR KEY COMBINATIONS FUNCTION SET YES (+) and NO (-) Getting to Home Position NOTES At any level in the MCA menus, pressing these two keys simultaneously takes you back to the "Normal Display" (beginning of menu tree). You can travel left to right from one menu to another by pressing this key. You can also go back to a specified menu by pressing this key while the menu's name is being displayed. FUNCTION SELECT Up Arrow and Down Arrow Moving Within a Menu Press the Up Arrow key to move up the list of available entries in the active menu. Press the Down Arrow key to move down the list of available entries in the active menu.

Moving from One Menu to Another Menu

FUNCTION SET ENTER

Changing a Control Function ALARM CUTOFF and FUNCTION SET ENTER

Changing a control function requires two (2) steps. 1) With the control function menu item being displayed, simultaneously press the FUNCTION SET ENTER and ALARM CUTOFF keys. 2) To accept the change, at the "ARE YOU SURE?+-" prompt press the FUNCTION SET YES (+) key. To reject the change, at the "ARE YOU SURE?+-" prompt press the FUNCTION SET NO (-) key.

Entering the Adjustment/Change Setting Mode

FUNCTION SET YES (+) or NO (-) Confirming the Change

Changing a Value or Setting ALARM CUTOFF and FUNCTION SET ENTER

Entering the Adjustment/Change Setting Mode

Changing a value or setting requires four (4) steps. 1) With the current value or setting being displayed, simultaneously press the FUNCTION SET ENTER and ALARM CUTOFF keys. The name of the value or setting begins to flash. 2) To increase the value or change the setting, press the FUNCTION SET YES (+) key. To decrease the value or change the setting, press the FUNCTION SET NO (-) key.

Changing the Value or Setting

FUNCTION SET YES (+) and NO (-)

FUNCTION SET ENTER Locking the Change

3) With the correct value or setting being displayed, press the FUNCTION SET ENTER key. 4) To accept the change, at the "ARE YOU SURE?+-" prompt press the FUNCTION SET YES (+) key. To reject the change, at the "ARE YOU SURE?+-" prompt press the FUNCTION SET NO (-) key.

FUNCTION SET YES (+) or NO (-) Confirming the Change

Page 3 of 4
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Section 6022 Issue AA, May 16, 2008 REVISION RECORD Issue AA Change Number (ECO) LLP210447 New Description of Change

Emerson Network Power, Energy Systems, North America, Inc. 1122 F Street / Lorain, Ohio 44052-2293 / (440) 288-1122 In Canada: Emerson Electric Canada Limited 122 Edward St. / St. Thomas, Ontario N5P 1Z2 / (519) 637-4900 In Mexico: Emerson Network Power de Mexico, S.A. de C.V. Apartado Postal 77001 / Mexico 10 D.F., MX 11200 / (525) 576-8277 Page 4 of 4
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

Das könnte Ihnen auch gefallen