Sie sind auf Seite 1von 4

BS08D

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Silicon Bilateral Switch

OUTLINE DRAWING C

B J A H D D
Description: The BS08D bilateral switch is a silicon planar monolithic integrated circuit with the electrical characteristics of a bilateral thyristor. The device is designed to switch at 7 to 9 volts with a 0.01%/C temperature coefficient and have excellently matched characteristics in both directions. Features: Low Switching Voltage of 7 to 9 Volts Excellent Switching Voltage Temperature Characteristics (0.01%/C) High Reliability Devices Gate Electrode Facilitating Switching Operation Control and Synchronization. Applications: Trigger Circuits for Thyristor or Triac, Oscillators, Timers
Millimeters 14.0 Min. 3.0 Max. 4.0 3.55 2.5 Max. 0.9 1.27 0.45 Type BS08D

F E

CONNECTION DIAGRAM

T2 TERMINAL GATE T1 TERMINAL

Outline Drawing Dimensions A B C D E F G H Inches 0.55 Min. 0.12 Max. 0.16 0.14 0.098 Max. 0.035 0.05 0.012 0.018

Ordering Information: Example: Select the complete five digit part number you desire from the table - i.e. BS08D is a 175mA Silicon Bilateral Switch.

TT-1

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 BS08D Silicon Bilateral Switch

Absolute Maximum Ratings, Ta = 25 C unless otherwise specified


Ratings DC Forward Anode Current Repetitive Peak Forward Current (1% Duty Cycle, 10s Pulsewidth), Ta = 100C Non-repetitive Peak Forward Current (10s Pulsewidth) Power Dissipation DC Gate Current Storage Temperature Operating Temperature PT IG Tstg Tj 2.0 450 5 -55 to 125 -55 to 125 Amperes mW mA C C Symbol IT BS08D 175 1.0 Units mA Amperes

Electrical and Thermal Characteristics, Tj = 25 C unless otherwise specified


Characteristics Switching Voltage Switching Current Absolute Switching Voltage Difference Absolute Switching Current Difference Holding Current Off-state Current Temperature Coefficient of Switching Voltage Peak On-state Voltage Gate Trigger Current Gate Non-trigger Voltage Symbol VS IS VS1-VS2 IS1-IS2 IH ID VT IGT VGD Test Conditions Ta = 25C Ta = 25C Ta = 25C Ta = 25C Ta = 25C VD = 5V, Ta = 25C VD = 5V, Ta = 85C Ta = -55 to 85C IT = 175mA, Ta = 25C VD = 5V, Ta = 25C VD = 5V, Ta = 85C Min. 7 10 0.2 BS08D Typ. 8 0.01 Max. 9 200 0.5 100 1.5 1.0 10 1.4 200 Units Volts A Volts A mA A A %/C Volts A Volts

TT-2

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 BS08D Silicon Bilateral Switch

OFF-STATE CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)

SWITCHING VOLTAGE VS.JUNCTION TEMPERATURE (TYPICAL)

SWITCHING CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)

101
VD = 5V
SWITCHING VOLTAGE, VS, (VOLTS)

8.3

320

SWITCHING CURRENT, IS, (A)

OFF-STATE CURRENT, ID, (A)

8.1

240
TYPICAL DISTRIBUTION

100

7.9

160

TYPICAL VALUE

10-1

7.7

80

10-2 -60 -40 -20 0 20 40 60 80 100 120 140


JUNCTION TEMPERATURE, Tj, (C)

7.5 -60 -40 -20 0 20 40 60 80 100 120 140


JUNCTION TEMPERATURE, Tj, (C)

0 -60 -40 -20 0 20 40 60 80 100 120 140


JUNCTION TEMPERATURE, Tj, (C)

ON-STATE VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)

HOLDING CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)

GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)

1.30
IT = 175mA
ON-STATE VOLTAGE, VT, (VOLTS) HOLDING CURRENT, IH, (A)

800
GATE TRIGGER CURRENT, IGT, (A)

160
VD = 5V TYPICAL DISTRIBUTION TYPICAL VALUE

1.20

600
TYPICAL DISTRIBUTION

120

1.10

400

TYPICAL VALUE

80

1.00

0.90

200

40

0.80 -60 -40 -20 0 20 40 60 80 100 120 140


JUNCTION TEMPERATURE, Tj, (C)

0 -60 -40 -20 0 20 40 60 80 100


JUNCTION TEMPERATURE, Tj, (C)

0 0 20 40 60 80 100
JUNCTION TEMPERATURE, Tj, (C)

GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)

0.8
GATE TRIGGER VOLTAGE, VGT, (VOLTS)

TYPICAL DISTRIBUTION

0.6

0.4

0.2
VD = 5V

0 0 20 40 60 80 100
JUNCTION TEMPERATURE, Tj, (C)

TT-3

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 BS08D Silicon Bilateral Switch

APPLICATION EXAMPLES THYRISTOR TRIGGER CIRCUIT


LOAD D R 220k VR 1M C 0.1 F -V CR2AM-8 CR

STATIC CHARACTERISTICS
+I VT1

EQUIVALENT CIRCUIT
T2

ID2 VS2

IH1 IS1 +V IS2 IH2 ID1 VS1

AC INPUT 100VAC

G
SBS BS08D R2 1k VT2

This circuit is widely used in DC motor contol and other control applications. T1

-I

TRIAC TRIGGER CIRCUIT


LOAD

CIRCUIT SYMBOL
T2

GATE CHARACTERISTICS MEASUREMENT CIRCUIT


47

D1

VR 200K R1 100, 0.25W D2 SBS BS08D C1 0.47F 25WV Triac BCR16 HM-8 R2 100 0.5W C2 0.1 F 400WV

A A
G

AC INPUT 100VAC R3 15k (1W)

V 5V V

10k

This circuit is useable in such applications as lighting control circuits, electric heater control, and other load control applications.

T1

TT-4

Das könnte Ihnen auch gefallen