Sie sind auf Seite 1von 1

Solution

The resolution must address the issues stated in the Symptom/Alarm Clearly state the actions required to resolve the issue

Alert Group Description Severity Actions

Notes

Picture

Open Cable

IDM - Indoor Module ODU - Outdoor Unit IF - Intermediate Frequency Cable Ceragon uses an IF cable to connect the IDM to the ODU as the coax can be up to 1KM Wind/storm stressing the cable on the antenna/tower Temperature Drop - Freeze causes solder joint to crack Temperature Drop - Freeze causes intermittant in cable join

Solution/Fix

Ceragon TroubleShooting Guide Cable Open IDM-ODU cable open 1) Check IF cable and connectors 2) Check ODU's N-type connector inner pin is not spliced (if yes, replace ODU). 3) Replace IDM. 4) Replace ODU.

Cable Open/Short

IDU-ODU cable open/short.

1) Check IF cable and connectors. 2) Check ODU's N-type connector inner pin is not spliced (if yes, replace ODU). 3) Replace IDU. 4) Replace ODU.

Note Alarm Time