Sie sind auf Seite 1von 19

2010-06-15

5011699700-S2S0

DVP-1160070-01

ENGLISH

Thank you for choosing Delta DVP-SS2. DVP-SS2 is a 14-point (8DI + 6DO) PLC MPU,
offering various instructions and with 8k steps program memory, able to connect to all
DVP-S series extension models, including digital I/O (max. 480 I/O points) and analog
modules (for A/D, D/A conversion and temperature measurement). 4 groups of
high-speed (10kHz) pulse output satisfy all kinds of applications. DVP-SS2 is small in
size and easy to install.
a This instruction sheet only provides introductory information on electrical
specifications, general specifications, installation and wiring. For detailed information
on programming and instructions, please refer to DVP-SS2 Operation Manual:
Programming. For information about optional peripherals, please see individual
product instruction sheet enclosed with DVP-SS2.
a This is an OPEN TYPE device and therefore should be installed in an enclosure free
of airborne dust, humidity, electric shock and vibration. The enclosure should prevent
non-maintenance staff from operating the device (e.g. key or specific tools are
required to open the enclosure) in case danger and damage on the device may
occur.
a DO NOT connect input AC power supply to any of the I/O terminals; otherwise
serious damage may occur. Check all the wiring again before switching on the power.
Make sure the ground terminal
is correctly grounded in order to prevent
electromagnetic interference. DO NOT touch any terminals when the power is
switched on.

Product Profile
25.20

1 3.00

60.00

2
9
12
90.00

EXTENSION
PORT

10
13

11

14

3.00
[ Figure 1 ]

Unit: mm
1. POWER, RUN, ERROR indicator

8. Nameplate

2. RUN/STOP switch

9. Extension port

3. I/O port for program communication (RS-232)

10. DIN rail mounting slot (35mm)

4. DIN rail clip

11. Extension unit clip

5. I/O terminals

12. RS-485 communication port

6. I/O point indicator

13. Mounting rail for extension module

7. Mounting hole for extension module

14. DC power input

Electrical Specifications
Model
Item

DVP14SS211R

DVP14SS211T

24VDC (-15% ~ 20%)


Power supply voltage (with counter-connection protection on the polarity of DC input power)
DVPPS01(PS02): input 100-240VAC, output 24VDC/1A(PS02: 2A)
Inrush current

Max. 7.5A@24VDC
-1-

Model

DVP14SS211R

Item
Fuse capacity

DVP14SS211T

1.85A/30VDC, Polyswitch

Power consumption

1.8W

Power protection

1.5W

With counter-connection protection on the polarity of DC input power

Insulation resistance

> 5M (all I/O point-to-ground: 500VDC)

Noise immunity

ESD: 8kV Air Discharge


EFT: Power Line: 2kV, Digital I/O: 1kV, Analog & Comm. I/O: 250kKV
RS: 26MHz ~ 1GHz, 10V/m

Grounding

The diameter of grounding wire cannot be smaller than the wire


diameter of terminals L and N (All DVP units should be grounded
directly to the ground pole).

Operation / storage

Operation: 0C ~ 55C (temp.), 50 ~ 95% (humidity), Pollution degree2


Storage: -25C ~ 70C (temp.), 5 ~ 95% (humidity)

Vibration / shock
resistance

International standards: IEC61131-2, IEC 68-2-6 (TEST


Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

Weight (g)

97g

82.5g
Input Point

Spec.
Items

24VDC (-15% ~ 20%) single common port input

Input No.

X0 ~ X3

Input type

X4 ~ X7
DC (SINK or SOURCE)

Input Current ( 10%)

24VDC, 5mA

Input impedance

4.7k

Max. frequency

20kHz

10kHz

Action
level

OffOn

> 15VDC

Response
time

OffOn

< 10s

< 20s

OnOff

< 20s

< 50s

OnOff

Filter time

< 5VDC

Adjustable within 0 ~ 20ms by D1020 (Default: 10ms)


Output Point

Spec.
Items

Relay

Output No.

Transistor

Y0 ~ Y5

Y0 ~ Y3

Max. frequency

1Hz

10kHz

Working voltage

250VAC, < 30VDC

Max. load
Response
time

Y4, Y5
1kHz
5 ~ 30VDC

#1

Resistive

1.5A/1 point (5A/COM)

Inductive

#2

15W (30VDC)

Lamp

20WDC/100WAC

2.5W (30VDC)

OffOn

0.5A/1 point (3A/COM)

Approx. 10ms

OnOff

20s

100s

30s

100s

#1: UP, ZP must work with external auxiliary power supply 24VDC (-15% ~ +20%), rated
consumption approx. 1mA/point.
#2: Life curves
120VAC Resistive
30VDC Inductive(t=7ms)

3000
2000

240VAC Inductive(cos = 0.4)

Operation(X10 3)

1000

120VAC Inductive(cos=0.4)

500
300
200
100
50

30VDC
Inductive
(t=40ms)

Contact

0.1

0.2 0.3

0.5 0.7

-2-

2 Current(A)

[ Figure 2 ]

I/O Configuration
Model

Input
Point

Type

Output
Point

14SS211R

DC
(Sink Or Source)

Relay

Transistor

Relay

S/S
X0
X1
X2
X3
X4
X5
X6
X7

S/S
X0
X1
X2
X3
X4
X5
X6
X7

C0
Y0
Y1
Y2

UP
ZP

14SS211T

I/O Configuration

Type

Transistor

C1
Y3
Y4
Y5

Y0
Y1
Y2
Y3
Y4
Y5

Note: The layout of output terminals on DVP-SS2 is different from that on DVP-SS.

Dimension & Installation


Please install the PLC in an enclosure with sufficient
space around it to allow heat dissipation, See
[Figure 3].
Direct Mounting: Use M4 screw according to the
dimension of the product.
DIN Rail Mounting: When mounting the PLC to
35mm DIN rail, be sure to use the retaining clip to
stop any side-to-side movement of the PLC and
reduce the chance of wires being loose. The retaining clip is at the bottom of the PLC.
To secure the PLC to DIN rail, pull down the clip, place it onto the rail and gently push
it up. To remove the PLC, pull the retaining clip down with a flat screwdriver and gently
remove the PLC from DIN rail.

Wiring
1. Use 22-16AWG (1.5mm) single or multiple core wire
22-16AWG
on I/O wiring terminals. See the figure in the right hand
side for its specification. PLC terminal screws should be
tightened to 1.90 kg-cm (1.65 in-lbs) and please use only
< 1.5mm
60/75C copper conductor.
2. DO NOT wire empty terminal. DO NOT place the I/O signal cable in the same wiring
circuit.
3. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring. Tear
off the sticker on the heat dissipation hole for preventing alien substances from
dropping in to ensure normal heat dissipation of the PLC.

Power Supply
The power input of DVP-SS2 is DC. When operating DVP-SS2, please note the
following points:
1. The power is connected to two terminals, 24VDC and 0V, and the range of power is
20.4 ~ 28.8VDC. If the power voltage is less than 20.4VDC, the PLC will stop running,
all outputs will go Off, and the ERROR indicator will start to blink continuously.
2. The power shutdown for less than 10ms will not affect the operation of the PLC.
However, the shutdown time that is too long or the drop of power voltage will stop the
operation of the PLC, and all outputs will go off. When the power returns to normal
-3-

status, the PLC will automatically resume the operation. (Please take care of the
latched auxiliary relays and registers inside the PLC when doing the programming).

Safety Wiring
Since DVP-SS2 is only compatible with DC power supply, Deltas power supply modules
(DVPPS01/DVPPS02) are the suitable power supplies for DVP-SS2. We suggest you
install the protection circuit at the power supply terminal to protect DVPPS01 or
DVPPS02. See the figure below.

c
e

AC power supply:100 ~ 240VAC, 50/60Hz

f
h
j
l

Power indicator

Breaker

Emergency stop: This button cuts off the system power supply when accidental
emergency takes place.

g
i
k

Power supply circuit protection fuse (2A)


DC power supply output: 24VDC, 500mA

AC power supply load


DVPPS01/DVPPS02
DVP-PLC (main processing unit)

Digital I/O module

Input Point Wiring


There are 2 types of DC inputs, SINK and SOURCE. (See the example below. For
detailed point configuration, please refer to the specification of each model.)
DC Signal IN SINK mode
Input point loop equivalent circuit

DC Signal IN SOURCE mode


Input point loop equivalent circuit

+24V

+24V

24G

24G

S/S

S/S
X0

X0
X1
X1

[ Figure 6 ]

[ Figure 5 ]

Output Point Wiring


1. DVP-SS2 has two output modules on it, relay and transistor. Be aware of the
connection of shared terminals when wiring output terminals.
2. Output terminals, Y0, Y1, and Y2, of relay models use C0 common port; Y3, Y4, and
Y5 use C1 common port. See [Figure 7]. When the output points are enabled, their
corresponding indicators on the front panel will be on.
-4-

3. Output terminals, Y0 ~Y5 of transistor models use UP, ZP common port. See [Figure
8].

4. Isolation circuit: The optical coupler is used to isolate signals between the circuit
inside PLC and input modules.
Relay (R) output circuit wiring

DC power supply

Fuse: Uses 5~10A fuse at the shared terminal of output contacts to protect the output circuit

Transient voltage suppressor (SB360 3A 60V): Extends the life span of contact.
1. Diode suppression of DC load: Used when in smaller power [Figure 10a]
2. Diode + Zener suppression of DC load: Used when in larger power and frequent On/Off
[Figure 10b]

Incandescent light (resistive load)

Manually exclusive output: For example, Y3 and Y4 control the forward running and reverse
running of the motor, forming an interlock for the external circuit, together with the PLC
internal program, to ensure safe protection in case of any unexpected errors.

Absorber: Reduces the interference on AC load [Figure 11]

Transistor (T) output circuit wiring

-5-

Emergency stop: Uses external switch

AC power supply

DC power supply

The output of the transistor model is open collector. If Y0/Y1 is set to pulse output, the
output current has to be bigger than 0.1A to ensure normal operation of the model.
1. Diode suppression: Used when in smaller power [Figure 13a]
2. Diode + Zener suppression: Used when in larger power and frequent On/Off [Figure 13b]

Manually exclusive output: For example, Y3 and Y4 control the forward running and reverse
running of the motor, forming an interlock for the external circuit, together with the PLC
internal program, to ensure safe protection in case of any unexpected errors.

Emergency stop

Circuit protection fuse

RS-485 Wiring
1 D+ D-

2 D+ D-

D+ D-

Figure 14

c
e

Master node

Slave node

Terminal resistor

Note: 1. Terminal resistors are suggested to be connected to master and the last slave with
resistor value of 120.
2. To ensure communication quality, please apply double shielded twisted pair cable
(20AWG) for wiring.

-6-

DVP DVP-SS2 14 8 + 6
PLC 8k steps
I/O 480

A/DD/A
10kHz

a
DVP-SS2

a OPEN TYPE
/

1 [Figure 1]mm
1. USB

8.

2. RUNSTOP

9. I/O

3. COM1 (RS-232)

10. DIN (35mm)

4. DIN

11. I/O

5.

12. COM2 (RS-485)

6.

13. I/O

7. I/O

14.

DVP14SS211R

DVPPS01(PS02) 100-240VAC 24VDC/1A (PS02: 2A)

Max. 7.5A@24VDC

1.85A/30VDC(Polyswitch)

protection

DVP14SS211T

24VDC (-15% ~ 20%) ()

1.8W

1.5W

> 5M ( 500VDC)

ESD: 8kV Air Discharge


EFT: Power Line: 2kV, Digital I/O: 1kV, Analog & Comm. I/O: 250kV
RS: 26MHz ~ 1GHz, 10V/m

PLC

0C ~ 55C50 ~ 95% 2
-25C ~ 70C5 ~ 95%
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)
97g

82.5g

-7-

24VDC (-15% ~ 20%)

No.

X0 ~ X3

S/S SINK SOURCE


24VDC, 5mA

(10%)

4.7k Ohm

20kHz

X4 ~ X7

10kHz

OffOn

> 15VDC

OnOff

< 5VDC

OffOn

< 10s

< 20s

OnOff

< 20s

< 50s

D1020 0 ~ 20 ms (10ms)

No.

Y0 ~ Y3

1Hz

10kHz

250VAC, < 30VDC

Y0 ~ Y5

Y4, Y5
1kHz
5 ~ 30VDC

#1

1.5A /1 (5A/COM)

#2

15W (30VDC)

20WDC/100WAC

2.5W (30VDC)

OffOn

10ms

OnOff

0.5A/1 (3A/COM)

20s

100s

30s

100s

#1UP, ZP 24VDC (-15% ~ +20%) 1mA/


#2[Figure 2]

14SS211R
14SS211T

(Sink or Source)

I/O

DVP-SS

PLC PLC
3 [Figure 3]
M4
DIN 35mm DIN
I/O
I/O

1. / 22-16AWG (1.5mm) 3
PLC 1.90 kg-cm (1.65 in-lbs) 60/75C
-8-

2.
3. PLC

DVP-SS2
1. 24VDC 0V 20.4 ~ 28.8VDC
20.4VDC PLC OffERROR LED
2. 10ms PLC
PLC OffPLC
PLC

DVP-SS2 DC Only
(DVPPS01/DVPPS02) DVP-SS2 DVPPS01/DVPPS02
4 [Figure 4]

100 ~ 240VAC, 50/60Hz

2A

DVPPS01/DVPPS02

24VDC500mA

DVP PLC

DC SINK SOURCE
4 [Figure 5][Figure 6]

1. DVP-SS2 PLC

2. Y0Y1Y2 C0 Y3Y4Y5 C1
5 [Figure 7]
3. Y0 ~Y5 UPZP 5 [Figure 8]
4. PLC

5 [Figure 9] ~ [Figure 11]

5 ~ 10A

1. DC 5 [Figure 10a]
2. DC +Zener On/Off
5 [Figure 10b]

Y3 Y4
PLC

5 [Figure 11]

-9-


5 ~ 6 [Figure 12] ~ [Figure 13b]

1. DC 6 [Figure 13a]
2. DC +Zener On/Off
6 [Figure 13b]

Y3 Y4
PLC

RS-485
6 [Figure 14]

c
e

1. 120
2. (20AWG)

- 10 -

DVP DVP-SS2 14 8 + 6
PLC 8k steps
I/O / 480
A/DD/A 10kHz

a
DVP-SS2

a (OPEN TYPE)

1 [Figure 1]mm
1. USB

8.

2. RUNSTOP

9. I/O

3. COM1 (RS-232)

10. DIN (35mm)

4. DIN

11. I/O

5.

12. COM2 (RS-485)

6.

13. I/O

7. I/O

14.

DVP14SS211R

24VDC (-15% ~ 20%) ()


DVPPS01(PS02) 100-240VAC 24VDC/1A (PS02: 2A)

Max. 7.5A@24VDC

1.85A/30VDC (Polyswitch)

DVP14SS211T

1.8W

1.5W

> 5M ( 500VDC)

ESD: 8kV Air Discharge


EFT: Power Line: 2kV, Digital I/O: 1kV, Analog & Comm. I/O: 250kV
RS: 26MHz ~ 1GHz, 10V/m

PLC

0C ~ 55C50 ~ 95% 2
-25C ~ 70C5 ~ 95%
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)
97g

82.5g
- 11 -

24VDC (-15% ~ 20%)

No.

X0 ~ X3

(10%)

24VDC, 5mA

4.7k Ohm

X4 ~ X7

S/S

20kHz

10kHz

OffOn

> 15VDC

OnOff

< 5VDC

OffOn

< 10s

< 20s

OnOff

< 20s

< 50s

D1020 0 ~ 20 ms (10ms)

No.

Y0 ~ Y3

Y4, Y5

1Hz

10kHz

1kHz

LED ON OFF

250VAC, < 30VDC

5 ~ 30VDC

1.5A /1 (5A/COM)

Y0 ~ Y5

#1

0.5A/1 (3A/COM)

#2

15W (30VDC)

20WDC/100WAC

2.5W (30VDC)

OffOn

10 ms

OnOff

20s

100s

30s

100s

#1UP, ZP 24VDC (-15% ~ +20%) 1mA/


#2[Figure 2]

14SS211R
14SS211T

()

I/O

(NPN)

DVP-SS

PLC PLC
3 [Figure 3]
M4
DIN 35mm DIN
I/O
I/O

1. / 22-16AWG (1.5mm) 3
- 12 -

PLC 1.90 kg-cm (1.65 in-lbs) 60/75C


2.
3. PLC

DVP-SS2
1. 24VDC 0V 20.4VDC ~ 28.8VDC
20.4VDC PLC OffERROR LED
2. 10ms PLC
PLC OffPLC
PLC

DVP-SS2 DC Only
(DVPPS01/DVPPS02) DVP-SS2 DVPPS01/DVPPS02
4 [Figure 4]

100 ~ 240VAC, 50/60Hz

2A

DVPPS01/DVPPS02

24VDC500mA

DVP PLC

DC DC
4~5 [Figure 5][Figure 6]

1. DVP-SS2 PLC -NPN -PNP

2. Y0Y1Y2 C0 Y3Y4Y5 C1
5 [Figure 7]
3. (NPN/PNP) Y0~Y5 UPZP 5
[Figure 8]
4. PLC

!!
5 [Figure 9] ~ [Figure 11]

5 ~ 10A

1. DC 5 [Figure 10a]
2. DC +Zener On/Off 5

[Figure 10b]

Y3 Y4
PLC

5 [Figure 11]
- 13 -

!!
5 ~ 6 [Figure 12] ~ [Figure 13b]

1. DC 6 [Figure 13a]
2. DC +Zener On/Off
6 [Figure 13b]

Y3 Y4
PLC

RS-485
6 [Figure 14]

1. 120
2. (20AWG)

- 14 -

.......

TRKE

.........

Deltann DVP-SS2 modelini setiiniz iin teekkrler. DVP-SS2 PLC 8k program


hafzas ile eitli komutlar sunar ve zerinde 14 nokta vardr (8DI + 6 DO). PLCye
Dijital giri/k modlleri (max. 480 giri/k nokta) ve analog modller (A/D, D/A
dntrc ve scaklk niteleri). ki grup yksek-hzl (10kHz) pulse k ve yeni
4-eksen interpolasyon komutlar ile birok uygulama iin tatmin edici zmler sunar.
DVP-SS2 rn kk lsyle kurulumu ok kolaydr.
a Bu bilgi dkman sadece rnn elektriksel zellikleri, genel fonksiyonlar, kurulumu
ve balants ile ilgili bilgiler salar. Detayl programlama ve DVP-SS2 uygulama
komutlar ile ilgili ltfen DVP-SS2 Operation Manual: Programming dkmann
inceleyiniz. Opsiyonel evre birimleri ile ilgili ltfen kutunun iindeki rnle birlikte
gelen bilgi dkmann inceleyiniz.
a Bu rn AIK TP bir PLCdir. PLC rn toz, rutubet, elektrik oku riski ve
titreimden uzak yerlerde muhafaza edilmelidir. Ayrca cihaza yetkili olmayan kiilerin
mdahale etmesini engelleyecek nlemler alnmaldr. (rnein rnn kurulduu
panoya kilit konulmas gibi). Aksi halde kullanclar ve/veya PLC zarar grebilir.
a Giri/k terminallerine kesinlikle AC besleme balamaynz. Aksi halde rn zarar
grebilir. Enerji vermeden nce rnn tm balantlarn kontrol ediniz.
dzgn yapldna emin
Elektromanyetik grlty nlemek iin topraklamann
olunuz. Enerjili iken rn terminallerine mdahale etmeyiniz.

rn Grn
ngilizce (English) blmnde ekil 1ye [Figure 1] baknz. Birim: mm.

Elektriksel zellikler
Model

DVP14SS211R

Madde

DVP14SS211T

24VDC (-15% ~ 20%)


(DC giri besleme ters balant korumas)
DVPPS01(PS02): giri 100-240VAC, k 24VDC/1A(PS02: 2A)

Besleme voltaj
Sznt Akm

Maksimum 7.5A@24VDC

Sigorta Kapasitesi

1.85A/30VDC, Polyswitch

G Tketimi

1.8W

Besleme Koruma

1.5W

DC giri besleme ters balant korumas

Izolasyon direnci

> 5M (Tm I/O nokta - ground: 500VDC)

Ses Bakl

ESD: 8kV Air Discharge


EFT: Power Line: 2kV, Digital I/O: 1kV, Analog & Comm. I/O: 250kV
RS: 26MHz ~ 1GHz, 10V/m

Topraklama

Topraklama kablosunun kesiti 24V - 0V terminalleri kablolar


kesitinden kk olmamaldr. (Tm DVP rnleri dorudan ground
ucundan topraklanmaldrlar).

alma/Saklama

alma: 0C ~ 55C (scaklk), 50 ~ 95% (rutubet), Kirlenme derece 2


Saklama: -25C ~ 70C (scaklk), 5 ~ 95% (rutubet)

Titreim/ok direnci

Uluslararas Standartlar: IEC61131-2, IEC 68-2-6 (TEST


Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
97g

Arlk (g)

82.5g
Giri Noktas

zellik.
Madde
Giri No.

24VDC (-15% ~ 20%) tek ortak u girii


X0 ~ X3
- 15 -

X4 ~ X7

Giri Noktas

zellik.
Madde

24VDC (-15% ~ 20%) tek ortak u girii

Giri Tipi

DC (SINK veya SOURCE)

Giri Akm ( 10%)

24VDC, 5mA

Giri Empedans
impedance

4.7k Ohm

Maksimum frekans
Aktif seviye
Cevap
Zaman

20kHz

10kHz

OffOn

> 15VDC

OnOff

< 5VDC

OffOn

< 10s

< 20us

OnOff

< 20s

< 50us

Filtre zaman

D1020 datasndan 0 ~ 20ms (Default: 10ms)


k Noktas

zellik
Madde

Rle

k No.
Maksimum frekans
alma Voltaj
Maksimum
Yk

Y1, Y3

1Hz

10kHz

250VAC, < 30VDC

Y4, Y5
1kHz
5 ~ 30VDC

#1

Rezistif

1.5A /1 nokta (5A/COM)

Endktif

#2

15W (30VDC)

20WDC/100WAC

2.5W (30VDC)

Lamba
Cevap
Zaman

Transistor

Y0 ~ Y5

OffOn

0.5A/1 nokta (3A/COM)

Yaklak 10ms

OnOff

20s

100s

30s

100s

#1: UP, ZP harici 24VDC (-15% ~ +20%) g kayna ile alr, g tketimi oran yaklak
1mA/nokta.
#2: ngilizce (English) blmnde ekil 2ye [Figure 2] baknz.

I/O Konfigurasyon
Model

Giri
Tip

DC
(Sink veya
Source)

14SS211R
14SS211T

Nokta

Nokta

I/O konfigurasyon
Tip

Rle

Transistor

Rle

ngilizce
(English)
blmnde
baknz

ngilizce
(English)
blmnde
baknz

6
Transistor

Not: DVPSS2 zerindeki k terminallerinin yerleim plan DVP-SSde olduundan


farkldr.

ller & Kurulum


Ltfen PLCnin kurulumunu yaparken s dalmnn verimli olmas iin evresinde
gerekli boluun brakldna emin olunuz.
Ltfen ngilizce (English) blmnde ekil 3e [Figure 3] baknz.
Dorudan Montaj: rnn llerine gre ltfen M4 vida kullannz.
DIN Ray Montaj: PLC rn 35mm DIN rayna monte edilecei zaman, rnn
hareket ederek kablo balantlarnn zarar grmesini engellemek iin sabitleyici klipsleri
kullannz. Sabitleyici klipsler PLCnin altnda olup, PLCyi DIN rayna sabitlemek iin bu
klipsleri bastrnz. PLCyi yerinden karmak iinse ince tornavida yardm ile nce bu
klipsleri anz ve PLCyi DIN rayndan ekerek kartnz.
- 16 -

Balant
1. PLCnin I/O terminal balantlarn yapmak iin
22-16AWG
22-16AWG (1.5mm) tek damarl veya ok damarl kablo
kullannz. Kablo zellikleri yandaki ekilde gsterildii
gibi olmaldr. PLC terminal vidalar 1.90 kg-cm (1.65
< 1.5mm
in-lbs) orannda sklmal ve sadece bakr iletkenler
kullanlmaldr.
2. Bo terminallere balant yapmaynz ve I/O sinyal kablolar ile power kablolarn
ayr kablo bloundan balaynz.
3. PLC kablo balantlarn yaparken PLCnin iine iletken paracklar drmeyiniz.
Balantlar tamamladktan sonra s dalmn salanabilmesi iin kk cisimlerin
PLCnin iine dmesini engelleyen koruyucu etiketleri kartnz.

G Kayna (Power Supply)


DVP-SS2 serisi rnlerin besleme girii DCdir. DVP-SS2 serisi rnleri kullanrken
aadaki uyarlara dikkat ediniz:
1. Besleme, 24VDC ve 0V terminallerine balanmal ve besleme voltaj 20.4 ~
28.8VDC aralnda olmaldr. Eer besleme voltaj 20.4VDC altna derse, PLC
almay durdurur, tm klar OFF olur ve ERROR indikatr srekli flash yapar.
2. 10 ms altndaki enerji kesintisi PLCnin almasna etki etmeyecektir. Fakat daha
uzun sureli bir enerji kesintisi veya voltaj dmesi durumunda PLC almas
duracak ve tm klar OFF olacaktr. PLCnin beslemesi normal duruma
dndnde, PLC otomatik olarak normal almasna geri dner.
(PLC programlanaca zaman iindeki kalc rle ve registerlerin kullanmna dikkat
ediniz).

Gvenli Balant
DVP-SS2 rnleri sadece DC voltaj ile beslenir. DELTAnn g kaynaklar (DVPPS01 /
DVPPS02), DVP-SS2 PLClerin beslemesi iin uygundur. DVPPS01 veya DVPPS02
rnlerini korumak iin power supply terminallerine koruyucu devre kurulmas nerilir.
ngilizce (English) blmnde ekil 4e [Figure 4] baknz.

1
3
4
6
8

AC power supply:100 ~ 240VAC, 50/60Hz

Devre kesici

Acil Stop: Acil durumda sistemin enerjisini kesmek iin kullanlr.


Power indikatr
Power supply devre koruma sigortas (2A)
DC power supply k: 24VDC, 500mA

5
7
9

AC power supply yk
DVPPS01/DVPPS02
DVP-PLC (Ana ilemci birimi)

Digital I/O modl

Giri Balants
2 eit DC giri vardr, SINK veya SOURCE. ngilizce (English) blmde ekil 5e
[Figure 5] ve ekil 6ya [Figure 6] baknz.

k Balants
1. DVP-SS2 serisi rnlerde 2 eit k vardr. Rle ve Transistr (NPN/PNP). k
terminal balantlarn yaparken ortak terminallerin kullanmna dikkat ediniz. (COM).
2. Y0, Y1, ve Y2 k terminalleri C0 ortak ucunu, Y3, Y4 ve Y5 k terminalleri C1
ortak ucunu kullanr. ngilizce (English) blmde ekil 7ye [Figure 7] baknz. k
terminallerinden biri aktif olursa o k terminaline karlk gelen indicator ON olur.
3. Y0 ~Y5 transistr k terminalli (NPN/PNP) modeller UP, ZP ortak ularn kullanr.
ngilizce (English) blmde ekil 8e [Figure 8] baknz.
4. zolasyon devresi: PLC i devreleri ve giri modlleri arasn izole etmek iin
optokuplr kullanlr.
- 17 -

Rle (R) k devre balants


Balant detay iin ngilizce (English) blmde ekil 9a - ekil 11e [Figure 9] ~
[Figure 11] baknz.

1
3
4

DC power supply

Acil stop: Harici switch kullanr.

Sigorta: k devrelerini korumak iin klarn ortak terminallerinde 5~10A sigorta kullanr.
Yksek gerilim darbe koruyucu (SB360 3A 60V): Kontak mrn uzatmak iin kullanlr.
1. DC yk diyot koruma: Dk power olduu zaman kullanlr. (ngilizce (English) blmde
ekil 10aya [Figure 10a] baknz).
2. DC yk Diyot + Zener koruma: Yksek power veya ok sk On/Off durumlarda kullanlr.
(ngilizce (English) blmde ekil 10bye [Figure 10b] baknz)

5
7

Akkor Lamba (resistif yk)

Dalga Emici (Absorber): AC ykteki grlty nlemek iin kullanlr. (ngilizce (English)
blmde ekil 11e [Figure 11] baknz)

AC power supply

Manual tek k: rnein, Y3 ve Y4 klar motorun ileri ve geri almasn kontrol etsin.
klarn ayn anda almasn ve beklenmeyen hatalar nlemek iin PLC programnda
ve harici devre balantsnda gerekli nlemler alnarak ayn anda sadece tek kn
almas salanabilir.

Transistr (T) k devre balants


Balant detay iin ngilizce (English) blmde ekil 12 ~ ekil 13bye [Figure 12] ~
[Figure 13] baknz.

1
4

DC power supply

Acil stop

Devre koruma sigortas

Transistor kl modeler ak kolektr(open collector) dr. Eer Y0/Y1 pulse k olarak


ayarlandysa, normal alma iin k akm 0.1Aden byk olmaldr.
1. Diyot koruma: Dk power olduu zaman kullanlr. (ngilizce (English) blmde
ekil 13aya [Figure 13a] baknz)
2. Diyot + Zener koruma: Yksek power veya ok sk On/Off durumlarda kullanlr
(ngilizce (English) blmde ekil 13bye [Figure 13b] baknz)

Manual tek k: rnein, Y3 ve Y4 klar motorun ileri ve geri almasn kontrol etsin.
klarn ayn anda almasn ve beklenmeyen hatalar nlemek iin PLC programnda
ve harici devre balantsnda gerekli nlemler alnarak ayn anda sadece tek kn
almas salanabilir.

RS-485 Wiring
ngilizce (English) blmde ekil 14ye [Figure 14] baknz.
1

Master istasyon

Terminal resistor

Slave istasyon

Not:
1. Terminal resistorun master ve son slave arasnda 120W olacak ekilde balanlmas nerilir.
2. Haberleme kalitesini arttrmak iin, ltfen balantda double shield (ift ekranl) twisted pair
(sarmal iftli) kablo (20AWG) kullannz.

- 18 -